Alarm Interpretation
Alarm Interpretation
Alarm Interpretation
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
ALARMS INTERPRETATION
SIGNAL NAME ALARM TEXT POSSIBLES CAUSES ACTIONS TO BE TAKEN
Check bearing.
BTGJ1_1_ALM BEARING METAL TEMP GEN #1 HIGH The generator bearing metal temperature #1 is very high
Check lube oil system and drain piping
BEARING METAL TEMP GEN The generator bearing metal temperature (journal #1) is Check bearing.
BTGJ1_2_ALM
JOURNAL #1 HIGH high Check lube oil system and drain piping
Check bearing.
BTGJ2_1_ALM BEARING METAL TEMP GEN #2 HIGH The generator bearing metal temperature #2 is very high
Check lube oil system and drain piping
BEARING METAL TEMP GEN The generator bearing metal temperature (journal #2) is Check bearing.
BTGJ2_2_ALM
JOURNAL #2 HIGH high Check lube oil system and drain piping
BEARING METAL TEMP TURBINE Check bearing.
BTJ1_1_ALM The turbine bearing metal temperature (journal #1) is high
JOURNAL #1 HIGH Check lube oil system and drain piping
BEARING METAL TEMP TURBINE Check bearing.
BTJ1_2_ALM The turbine bearing metal temperature #1 is very high
JOURNAL #1 HIGH Check lube oil system and drain piping
BEARING METAL TEMP TURBINE Check bearing.
BTJ2_1_ALM The turbine bearing metal temperature (journal #2) is high
JOURNAL #2 HIGH Check lube oil system and drain piping
BEARING METAL TEMP TURBINE Check bearing.
BTJ2_2_ALM The turbine bearing metal temperature #2 is very high
JOURNAL #2 HIGH Check lube oil system and drain piping
BEARING METAL TEMP TURBINE Check bearing.
BTJ3_1_ALM The turbine bearing metal temperature (journal #3) is high
JOURNAL #3 HIGH Check lube oil system and drain piping
BEARING METAL TEMP TURBINE Check bearing.
BTJ3_2_ALM The turbine bearing metal temperature #3 is very high
JOURNAL #3 HIGH Check lube oil system and drain piping
BEARING METAL TEMP THRUST Check bearing.
BTTA1_2_ALM The bearing metal temperature (thrust active) is high
ACTIVE 2 HIGH Check lube oil system and drain piping
BEARING METAL TEMP THRUST Check bearing.
BTTA1_5_ALM The bearing metal temperature (thrust active) is high
ACTIVE 5 HIGH Check lube oil system and drain piping
BEARING METAL TEMP THRUST Check bearing.
BTTA1_8_ALM The bearing metal temperature (thrust active) is high
ACTIVE 8 HIGH Check lube oil system and drain piping
BEARING METAL TEMP THRUST Check bearing.
BTTI1_2_ALM The bearing metal temperature (thrust inactive) is high
INACTIVE 2 HIGH Check lube oil system and drain piping
BEARING METAL TEMP THRUST Check bearing.
BTTI1_5_ALM The bearing metal temperature (thrust inactive) is high
INACTIVE 5 HIGH Check lube oil system and drain piping
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
GEN STATOR WIND. CENT. TEMP Generator Overload Decrease the generator load
L26GS2HH_ALM
VERY HIGH #4-5-6 2 of 3 Generator RTDs failure Check RTD and associated connections
GEN STATOR WIND. CENT. TEMP Generator Overload Decrease the generator load
L26GS3HH_ALM
VERY HIGH #7-8-9 2 of 3 Generator RTDs failure Check RTD and associated connections
GEN STATOR WIND. CENT. TEMP Generator Overload Decrease the generator load
L26GS4HH_ALM
VERY HIGH #10-11-12 2 of 3 Generator RTDs failure Check RTD and associated connections
GEN STATOR WINDING CENTER Generator Overload Decrease the generator load
L26GS4T6H_AL
TEMP HIGH #4-5-6 2 of 3 Generator RTDs failure Check RTD and associated connections
GEN STATOR WINDING CENTER Generator Overload Decrease the generator load
L26GS7T9H_AL
TEMP HIGH #7-8-9 2 of 3 Generator RTDs failure Check RTD and associated connections
HEAT VENT VERY HIGH TEMP. IN
L26HA11HH_AL DLN compartment temperature very high Start cooling fans
DLN COMPARTMENT
HEAT VENT VERY LOW TEMP. IN DLN
L26HA11LL_AL DLN compartment temperature very low Check cooling fans
COMPARTMENT
HEAT VENT VERY HIGH TEMP. IN
L26HAHH_ALM Accessories compartment temperature high Start cooling fans
AUXILIARY COMPARTMENT
HEAT VENT VERY LOW TEMP. IN
L26HALL_ALM Heating and ventilation fault Check heating and ventilation system
AUXILIARY COMPARTMENT
HEAT VENT HIGH TEMP. IN LOAD
L26HGHH_ALM Heat vent very high temp. In load compartment Check cooling and sealing system
COMPARTMENT
HEAT VENT VERY LOW TEMP. IN
L26HGLL_ALM Heat vent very low temp. In load compartment Check cooling and sealing system
LOAD COMPARTMENT
HEAT VENT VERY HIGH TEMP. IN
L26HTHH_ALM Gas turbine compartment temperature high Start cooling fans
TURBINE COMPARTMENT
HEAT VENT VERY LOW TEMP. IN
L26HTLL_ALM Turbine compartment temperature low. Check the ventilation system.
TURBINE COMPARTMENT
PERF MONIT INSTRUM BOX #1 TEMP Performance monitoring instrumentation box #1 temperature Check performance monitoring instrumentation box #1
L26PMBT1L_AL
VERY LOW regulation fault temperature regulation
PERF MONIT INSTRUM BOX #2 TEMP Performance monitoring instrumentation box #2 temperature Check performance monitoring instrumentation box #2
L26PMBT2L_AL
VERY LOW regulation fault temperature regulation
Check for proper operation of the lube oil heat
exchangers, cooling water fans (proper rotation) and
Lube header temperature above recommended limits. (See
L26QA_ALM LUBE OIL HEADER TEMP. HIGH temperature regulating valve VTR_1.
piping schematic).
Check for proper operation of the temperature switch
26 QA_1.
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
125VDC POWER SUPPLY FAULT #1 Check 115 VDC MCC electrical circuit
L30DC1_ALM 115 VDC MCC voltage lost
ALARM Check voltage feeding
DEW POINT TEMPERATURE SENSOR
L30DPFLT_ALM Dew point temperature sensor fault Change dew point temperature sensor
FAULT
L30EX_FSP EXCITER FAILURE TO STOP Exciter failure to stop Check exciter cubicle
L30EX_FTS EXCITER FAILURE TO START Exciter failure to stop Check exciter cubicle
L30EX_RS EXCITER NOT READY TO START Exciter not ready to start Check the condition to start
CRUDE OIL FWD SMOKE INHIBITION
L30FAX_ALM For information For information
PUMP CHANGE OVER
HEAVY FUEL ADDITIVE PUMP #1
L30FAX1_ALM Heavy Fuel Additive pump #1 fault Check the pump # 1
FAULT
HEAVY FUEL ADDITIVE PUMP #1
L30FAX2_ALM Heavy Fuel Additive pump #2 fault Check the pump # 2
FAULT
COOLING WATER FAN 1 ELECTRICAL Check electrical circuit
L30FC1_ALM The motor of the cooling water system fan #1 is faulty
TROUBLE Check motor fan #1
COOLING WATER FAN 2 ELECTRICAL Check electrical circuit
L30FC2_ALM The motor of the cooling water system fan #2 is faulty
TROUBLE Check motor fan #2
Check that AC power is supplied to the ignition system.
Check the fuel supply.
L30FD_ALM FAILURE TO IGNITE Failure to fire within the one-minute period. Check if isolating valves on flame detectors are open.
Check the proper operation of spark plugs and flame
detectors.
L30FDX1_ALM FUEL FORWARDING PUMP #1 FAULT Fuel forwarding pump #1 fault Check. Fuel forwarding pump #1
L30FDX2_ALM FUEL FORWARDING PUMP #2 FAULT Fuel forwarding pump #2 fault Check. Fuel forwarding pump #2
L30FORCED_ALM FORCED LOGIC SIGNAL DETECTED One alarm or more is forced Unforced all the alarms
Check gas compartment ventilation.
The high line inter-valve ventilation is faulty.
GAS FUEL INTERVALVE PRESSURE Check motors.
L30FPG2L_ALM Emergency motor fault
(P2) LOW Check mechanical status of fans.
Power supply fault
Check pressure switches.
Check the pump and corresponding motor
CRUDE OIL FWD CRUDE OIL Check if the motor is supplied.
L30FUX_ALM Pump, motor fault.
FORWARDING PUMP FAULT Check the pipes, valves, and filters, purge vents, leaks.
Check the pressure switches (operation and setting).
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
HEAT VENT WI COMPARTMENT Air fan changeover. Check the air fan system (power supply, motors, fans,
L30JSX_ALM
VENT. CHANGE OVER Water injection compartment air fan fault. relay, electrical circuit...).
Check lube oil feed and drain piping
Bearing fault. Check bearings and lube oil system.
BEARING DRAIN TEMPERATURE Lube oil fault. Check thermocouples.
L30LOAH_ALM
HIGH Lube oil cooling system fault. Check lube oil cooling.
Leakage. Check the correct circulation of the lube oil.
Check for leakage.
BEARING DRAIN TEMPERATURE
L30LOAHH_ALM See alarm : L30LOAH_ALM See alarm : L30LOAH_ALM
HIGH
L30LSI_ALM AIRCRAFT WARNING LIGHT ALARM Aircraft warning ligh alarm For information
Check the proper operation of ventilation system.
Check the operation of the ventilators (rotation).
Automatic shutdown.
Check the operation of the motors 88 TK1 and 2.
L30LTA LOAD TUNNEL TEMPERATURE HIGH Ventilation system fault.
Check the thermocouple TT_IB_1 (connection, short-
Thermocouple fault.
circuit, cut off, position).
Check the sealing and the cleanliness of the pipes.
L30LTTH_ALM LUBE OIL THERMOCOUPLE FAULT Thermocouple fault Check the proper operation of thermocouples LTTH1 to 3.
SYNC INHIBITED-MAN (FVR) REG
L30MRSYNC_AL Sync inhibited man (FVR) reg active. For information
ACTIVE
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
HEAT VENT AUXILIARY The door of the compartment auxiliary is open. Check the air inlet filter system.
L33DT2_ALM
COMPARTMENT DOOR OPEN Limit switch fault. Check the limit switch 33 DT2.
HEAT VENT AUXILIARY The door of the compartment auxiliary is open. Check the air inlet filter system.
L33DT3_ALM
COMPARTMENT DOOR OPEN Limit switch fault. Check the limit switch 33 DT3.
WATER INJECT COMP FLAP DAMPER
L33JS_ALM Water inject comp flap damper not closed. Check damper
NOT CLOSED
Check the proper operation of:
_ Purge valves VA13_1 and VA13_2
Either one or both of purge valves VA13_1and VA13_2 not
_ Air valves VA36_1 and VA36_2
PRIMARY PURGE VALVES FAILURE functioning correctly.
L33PGC_ALM _ Solenoid valves 20PG_1 and 20PG_2.
TO CLOSE Either one or both of limit switches 33PG_1 and 33PG3 not
Check Speedtronic connections and interface.
functioning correctly.
Check the limit switches 33PG_1 and 33PG_3 for set
point and Speedtronic connections.
Check the proper operation of the purge valves VA 13_1
and VA 13_2.
GAS FUEL NOZ. PURGE VALVE FAIL Check the status of the solenoid valves 20 PG_1 and
L33PGO_ALM The purge valves VA 13_1 and VA 13_2 failed to open.
TO OPEN 20 PG_2.
Check the proper operation of the limit switches 33 PG_2
and 33 PG_4.
PRIMARY LIQUID FUEL LOW PURGE No detection of opening on liquid fuel purge system when
L33PLP_ALM Control liquid fuel purge valve position (hi flow valve)
FAULT purge is requested
This alarm indicates the wrong position of the vent valve:
Check that noting is blocking the valve
The valve is blocked
L33PS1C_ALM VENT VALVE FSV452 NOT CLOSED Check the limit switch
Valve fault
Check the valve
Limit switch fault
This alarm indicates the wrong position of the vent valve:
Check that noting is blocking the valve
VENT VALVE LIMIT SWITCH NOT The valve is blocked
L33PS2O_ALM Check the limit switch
OPEN Valve fault
Check the valve
Limit switch fault
GENERATOR HOT GAS
L33PSC_ALM Generator hot gas temperature high Refer to specific chapter
TEMPERATURE HIGH
GAS FUEL VENT VALVE OPEN
L33PSO_ALM Gas Fuel Vent Valve Open position trouble Check limit switch and valve
TROUBLE
L33S_ALM AUTOMATIC VALVES FAULT Automatic valves fault Check valve
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
HEAVY FUEL TEM. FAULT XFERT The temperature of the heavy fuel is not correct. The
L86FT_ALM Check heavy fuel heating system
LOCKOUT transfer is locked.
COMPLETE LOSS OF HEAVY FUEL Complete loss of heavy fuel FWD pumps crude oil FWD
L86FUX_ALM Check pumps.
FWD PUMPs additive pumps.
74/86G-1A LOCK OUT RELAY COIL
L86G1AMON_AL 74/86G-1A lock out relay coil fault Check 74/86G-1A
FAULT
Lockout relay 74/86G-1B is faulty.
74/86G-1B LOCK OUT RELAY COIL
L86G1BMON_AL Wiring circuit in GCP sequence Check relay
FAULT
Tripping coil of the 52G circuit breaker is faulty.
L86G2AALM_AL 74/86G-2A LOCK OUT RELAY TRIP 74/86G-2A lock out relay trip Check 74/86G-2A
74/86G-2A LOCK OUT RELAY COIL
L86G2AMON_AL 74/86G-2A lock out relay coil fault Check 74/86G-2A
FAULT
The lockout 74/86G-2B relay tripped in the GCP and sent
L86G2BALM_AL 74/86G-2B LOCK OUT RELAY TRIP Check 74/86G-2B
opening order 41E and 52G breakers
Lockout relay 74/86G-2B is faulty.
74/86G-2B LOCK OUT RELAY COIL
L86G2BMON_AL Wiring circuit in GCP sequence Check relay
FAULT
Tripping coil of the 52G circuit breaker is faulty.
Start inhibited + transfer to fuel if running on gas or transfer
to gas inhibited.
Check LVDT, 96 GC_1, 2 (setting value, wiring).
GAS CONTROL VLV NOT The gas control valve feedback is abnormal.
L86GCVT_ALM Check the calibration of the VGC.
FOLLOWING - TRIP Supply fault.
Check the proper operation of the servo-valve 65 GC_1.
Sensors defected.
Valve and servo-valve fault.
L86GLTA_ALM
GAS LEAK TEST OF SRV FAILED Gas leak of SRV valve Check SRV valve
GAS LEAK TEST OF GCV/VENT
L86GLTB_ALM Gas leak of GCV valve or Gas Purge Inter valve Check GCV valve or Gas Purge Inter valve
FAILED
2/3 GEN STATOR WIND. CENT. TEMP Temperature sensor fault Decrease the generator load
L86GSC10T12A
SNSR FLT #10-11-12 2 of 3 Generator RTDs failure Check RTD and associated connections
2/3 GEN STATOR WINDING CENTER Temperature sensor fault Decrease the generator load
L86GSC1T3_AL
TEMP SNSR FLT #1-2-3 2 of 3 Generator RTDs failure Check RTD and associated connections
2/3 GEN STATOR WINDING CENTER Temperature sensor fault Decrease the generator load
L86GSC4T6_AL
TEMP SNSR FLT #4-5-6 2 of 3 Generator RTDs failure Check RTD and associated connections
2/3 GEN STATOR WINDING CENTER Temperature sensor fault Decrease the generator load
L86GSC7T9_AL
TEMP SNSR FLT #7-8-9 2 of 3 Generator RTDs failure Check RTD and associated connections
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Check relay
L86T1AALM_AL 74/86T-1A LOCK OUT RELAY TRIP 74/86T-1A Lock out relay coil fault
Check GCP
74/86T-1A LOCK OUT RELAY COIL Check relay
L86T1AMON_AL 74/86T-1A Lock out relay coil fault
FAULT Check GCP
COMPRESSOR INLET
L86TCI Bad thermocouple signal. Check thermocouples and wiring.
THERMOCOUPLES DISAGREE
Trip. Check and reconnect thermocouples.
EXHAUST THERMOCOUPLES OPEN
L86TFB_ALM Excessive number thermocouples fault. Check the connection and the position.
TRIP
Position, connection, short-circuit, cut-off fault. Check for short-circuit and cut-off.
FALSE START DRAIN VALVE FAIL TO Check limit switch wiring and good operation. Look for
L86TFD_C Valve stucked or limit switch failure
CLOSE valve bloquage.
FALSE START DRAIN SYSTEM Look for any foreign object or residual fuel in drain piping.
L86TFD_NOFLOW Drain system clogged.
BLOCKED Check valve operation.
FALSE START DRAIN VALVE Check limit switch wiring and good operation. Look for
L86TFD_O Valve stucked or limit switch failure
FAILURE TO OPEN valve bloquage.
FSD VALVE CLOSED AT LOWER
L86TFDLOW_AL Valve spring damaged Check valve spring.
PRESS THAN EXPECTED
GENERATOR DIFFERENTIAL TRIP Electrical trouble with emergency shutdown. Relay 86G The unit should not be operated until the cause of the
L86TGT1_ALM
CHANNEL 1 indicate a generator differential. problem has been determined and corrected.
GENERATOR DIFFERENTIAL TRIP Electrical trouble with emergency shutdown. Relay 86G The unit should not be operated until the cause of the
L86TGT2_ALM
CHANNEL 2 indicate a generator differential. problem has been determined and corrected.
Investigate problem. The problem should be corrected
before restarting. The Master Reset switch must be
pressed before restarting.
L86TVA_ALM POSITION IGV FAULT On start-up, the inlet guide vanes are not closed.
NOTE:
Refer to Manufacturers documents and to Control
specification for proper values.
The temperature control system has not limited exhaust
temperature within the trip limits. Check the temperature control loop and the fuel control
L86TXT_ALM EXHAUST OVERTEMPERATURE TRIP Temperature control system fault. system.
Fuel control system fault. Check the cooling and ventilation system.
Ventilation system fault.
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION
LFQGUV_ALM FUEL GAS FLOW OUT OF RANGE The fuel gas system is in trouble. Check the fuel gas system and the gas skid.
FLOW DIVIDER FUEL HIGH FLOW
LFQLDIFF_ALM Flow divider fuel high flow difference Check flow divider.
DIFFERENCE
SRV OPEN AT 90 % - RISK OF TRIP
LFSGRH_ALM For information Check the regulated constants.
ON HIGH EXH TEMP
SRV VLV OPEN AT 95 % - XFER TO
LFSGRHH_ALM For information Check the regulated constants.
LIQUID FUEL TEMP.
COMP LIMIT FSR BACKUP CONTROL Check the regulation system.
LFSRCPR_ALM Regulation system fault.
ACTIVE Check operation of bleed heat control valve.
GAS FUEL TEMPERATURE TC Check the thermocouples FT_GI_1, 2 and 3 (connection,
LFTG_ALM Thermocouples fault.
TROUBLE wiring and operation).
FREQUENCY OUT OF LIMIT FOR GC
LGCTESTOF_AL Indication about NGC test For information
TEST. NEED MRST
LNGC_ON_ALM NGC TEST PB ACTIVATED Indication about NGC test For information
GOV TEST ENABLED - SELECT NGC
LNGCPERM_ALM Indication about NGC test For information
DISABLED AFTER TEST
OVERFREQ OPERATION AT MAX Total operating time in over frequency greater
LOF_LIM_ALM Turbine shutdown for boroscopic inspection recommanded
TIME. INSPECTION REQU'D than the allowable limit
LPROFILE_ALM PROFILE TEST PB ACTIVATED Indication about profile test
Check the mechanical status of the motor and the pump.
Motor, pump fault
LQEP2N_ALM DC PUMP ABNORMAL PRESSURE Check the motor supply (fuses, breaker, connection)
Transducer fault
Check transducer
EMERGENCY LO PUMP DISCH Check 4-20mA 96QE-2 transmitter (connections, cables.).
LQEP2NFLT_ALM 4-20mA 96QE-2 fault
PRESS TRANSDUCER FAILURE Replace transmitter if necessary.
Check the lube oil feed and drain piping
The delta temperature between turbine bearings fault
Check turbine bearings and lube oil system
LUBE OIL TEMP BRG DELTA TEMP Turbine bearings fault
LTBRGH_ALM Check thermocouples
HIGH Lube oil fault
Check for leakage
Leakage
Check the correct circulation of the lube oil.
LUBE OIL TEMP BRG DELTA TEMP
LTBRGHH_ALM See alarm : LTBRGH_ALM See alarm : LTBRGH_ALM
HH
Rev : A
OPERATION AND MAINTENANCE MANUAL
OPERATION