Cast Resin Transformer

Download as pdf or txt
Download as pdf or txt
You are on page 1of 16

Cast Resin Transformer

SGB Starkstrom (Germany)

First Class Transformers for First Class Customers


2

Why Cast Resin Transformers from SGB ?


SGB are able to deliver Cast Resin Transformers with capacities up to 25 MVA and series
voltages up to 36 kV. With more than 30 years experience in the construction of cast resin
transformers, SGB has worldwide expertise, and this is expressed in the remarkably high quality
coefficients such as meantime between failure (MTBF) of over 1,700 years.
Thanks to their unique design, SGB Cast Resin Transformers offer a range of features
which set them apart technically from other cast resin transformers and make them a very
dependable and very reliable solution.

For you customer this means the following operational advantages :


- High impulse voltages are controlled safely.
- Thermal withstand capability makes overload possible.
- Expansion and contraction of coils in service is tolerated, even for short circuits.
- Long service life is guaranteed.
3

High voltage winding


The high voltage winding is the centerpiece
of the cast resin transformer. Herein lies SGBs great
technical know-how. Core and low voltage winding
are also important for the overall design, as all
components are naturally interdependent.

One of the characteristics of cast resin


transformers is that the conductors of the high
voltage winding are completely encapsulated in a cast
resin body with a smooth surface. This can only be
carried out in moulded formers under vacuum. SGBs
production technology and materials used can also
be distinguished through important unique features
which set them apart technically from other cast resin
transformers and make them a very dependable and
very reliable solution.

R eserves-equipped
Overloads are permissible due to the thermal reserves provided by specific primary insulation.
E ndurance-enhanced
Cooling ducts guarantee long service life.
S urge-proof
The double layer winding technology enables the control of high impulse voltages.
Q uantum-leap
Glass fiber reinforcement of windings ensures that during operation, when the winding heats and
expands, the design has the flexibility to react without damage to the winding even under short
circuit conditions.

For our customers these specific features mean a high level of safety both in relation to operation
and their investment decision.
4

"Resin Quality SGB"


These exceptional factors of quality are subsequently explained in detail below.
As the operating temperature of SGB Cast Resin Transformers rarely reaches the limit of the
temperature class F (155 C), the primary insulation has sizeable temperature reserves.

R eserves equipped
Thermal loads make overload possible
SGB Cast Resin Transformers not only have an advantage over oil transformers but also cast
resin transformers incorporating established alternative designs. These transformers use a high voltage
winding design where the conductor consists of copper foil strip and the coil/layer insulation is
plastic. The insulation level of this type of system can only be considered as class F, when considering
the insulation system as a whole. It is quite different with SGB Cast Resin Transformers as SGB uses
insulated profile wires for a double layer winding where the primary insulation either consists of a
high heat resistant polyesterimide coating with a temperature index of 200C or Nomex thread
winding of the temperature class C (220 C).
5

E ndurance-enhanced
Guaranteed high service life
Cast resin transformers must emit the resulting heat in the windings over the surface
area of the coils to the cooler air surrounding the transformer. This has to be achieved
with respect to the winding insulation class and without exceeding the average winding
temperature, or the Hot-Spot temperature. The necessary cooling requirements can be
calculated by considering the heat transfer coefficient, the ambient temperature, the surface
temperature of the coil, and the size of the surface area.

With cast resin transformers of alternative designs, only the inner and outer surface
areas of the high voltage cylindrical coil are available for cooling. To provide the necessary
surface areas for cooling, the coils must be larger. SGB's design of a double layer winding
in comparison simply allows for the introduction of additional cooling ducts inside the coil.
In this way very efficient cooling is achieved. SGB Cast Resin Coils can therefore be equipped
with several cooling ducts.

SGB Cast Resin Transformers use appropriate materials and design to guarantee
a consistent distribution of temperature inside the coil. The optimized cooling enables a
reduction in temperature for the high voltage winding and furthermore a consistently
distributed temperature for the entire transformer.
6

S urge-proof
High impulse voltages are controlled safely
Only SGB Cast Resin Transformers mould their high voltage coils in vacuum combined with
a double layer winding. This ensures safety in the control of impulse voltages brought about by, for
example, lightning strikes or vacuum switches.

Regular coil winding of other transformers leads to much greater voltage stress, especially on the
input coils, because 70% of the shock impact does not apply on the first 30% of the coils. The risk of
winding short circuits therefore increases significantly.
The SGB double layer winding by contrast guarantees linear fault distribution for all windings.
7

Q uantum-leap
Overcome temperature shocks reliably
Cast resin transformers are subject to great mechanical and thermal shocks and strains in
their transport and in particular when operated. Therefore of great importance is the ability of the
transformers to safely control spasmodic temperature increases.

A decisive factor in this feature is the construction of


the cast resin composite material, into which the conductors
are moulded. This depends especially upon the tensile stress
and the thermal coefficients of expansion of the composite
material in relation to the winding material. With many cast
resin transformers this composite material is comprised of
epoxy resin which is mixed to over 70% with a mineral bulking
agent, mainly quartz powder. Such a composite material can
reach the tensile strength of the epoxy resin, about 50 N/mm.
With the thermal coefficients of expansion the value of
aluminium can roughly be met with maximum mineral filling
but remains clearly above that of copper. This is the reason why
cast resin transformers of usual technology were only available
for decades with aluminium conductors. Recently there has
been an improvement through an additional concentration of
glass fiber on the surface.

It is quite different with SGB. Here the composite system


is comprised of glass fiber concentrated epoxy resin between
the layers and on the surface with high tensile strength in the
area of 120 N/mm and a coefficient of expansion which is
equally close to that of copper and aluminium. SGB Cast Resin
Transformers are produced with copper winding materials.
Casting has always occurred under vacuum and is therefore
free of voids. The advantage of the SGB composite system has
frequently been recognized in tests. With an exit temperature
of -50C, SGB Cast Resin Coils have also safely passed the
required temperature shock tests in accordance with IEC
60076-11 for climate class C2 based on a temperature of -25 C.
8

Core
With the calculation of cores for Cast resin transformers, no-load losses, noises and no-load currents
are quite considerable and in many cases, crucial quality features. As a result, the choice of high-quality
materials for core design and manufacture is vital.
For SGB Cast Resin Transformers a cold-rolled, grain-oriented magnetic plate is used and has a
typical loss factor of 0.85 W/kg. In most cases of application, values according to the requirements for no-
load losses and noises can be reached. For special requests a so-called Hi-B plate is used with which the
no-load losses can then be reduced further by approximately 15% and the noise level by around 5-7dB(A),
so that for specific applications, e.g. in hospitals, low losses and reduced noise requirements are met.
The cores themselves are manufactured on modern transverse and core-laying machines, which
guarantee a shift in the so-called step lap process with extreme precision. Put simply, the single sheets
are tapped in the usual step lap process by means of a repeated overlap and as a result the losses are
reduced.
For corrosion protection, a high temperature 2-component coating is used. This coating gives
protection to the core against the environmental elements to which it would be subjected. The coating also
infiltrates between the individual core sheets and sticks them together which gives further benefits when
handling noise and vibrations.
The core is fixed with a holding frame consisting of lower and upper clamping bars and flat-rolled
tie rods directly on the core. The tie rods consist of magnetic flat-rolled steel and connect the lower and
upper clamping bars together. The holding frame is constructed in such a way that the core plates are kept
free from tensile load and compressive stress as far as possible because, as such, they retain their excellent
features in relation to losses and noises. The lower yoke is allowed to rest, supported through mouldings
made from glass fiber-strengthened synthetic material onto the lower chassis pillar to which bidirectional
adjustable coils can be fixed. Different attachments such as additional footbridges, tubs, vibration-reducing
components and others can indeed be chosen depending on the individual project and client requirements.
9

Low voltage winding


SGB Cast Resin Transformers low voltage winding
is almost always used as a full length foil winding.
The advantages of this form of winding are evident:
Reduction of additional losses.
Even temperature distribution in the coil.
High short circuit consistency.

Exceptions exist if the LV winding is rated as less than


160 kVA or has a voltage rating of over 3 kV.

For more than 40 years SGB has been producing


foil windings for distribution transformers and cast resin
transformers. This long expertise is the reason for high
quality features such as:

SGB uses treated material exclusively from foil


manufacturers in special cylinders to guarantee that the
edges are burr-free. This is an important requirement
for electrical dependability.
To connect the outbound connection edges with
the tapes, there are two common practices, welding
under inert gas or cold welding under high pressure
(400kN). Cold welding has been used for more than
20 years at SGB.

Benefits:
- No metallurgic changes of the winding material
by means of a temperature process.
- No foreign bodies which can occur with moulding.

By using multi-layer prepregs, there is a high-strength, thick-walled cylinder, which can accommodate
the radial short circuit force unsupported-compared with the otherwise standard solutions.
10
11
12

Quality
Guaranteed high service life
The manufacture of cast resin transformer is of course certified within SGB in accordance with
ISO 9001 and ISO 14001. As a provider to OEM customers with high quality standards, we are familiar
with challenging quality systems such as, Six-sigma. Classification societies such as Germanischer Lloyd,
RINA or Bureau Veritas have approved SGB Cast Resin Transformer. SGB has been producing cast resin
transformers for over 30 years and therefore has the greatest wealth of experience in this field worldwide.
This remarkable know how is reflected in exceptionally high quality coefficients, such as MTBF of over
1,700 years. SGB Cast Resin Transformers naturally comply with all the usual quality standards such as:

Fire class F1.


Environmental class E2.
Climatic class C2.
13

Tests
SGB Cast Resin Transformers are designed and produced as standard in accordance with
IEC 60076-11. SGB Cast Resin Transformers comply with all the tests required in IEC 60076-11
All detailed inspections and type tests, e.g. short circuit tests or temperature rise tests as well
as many special tests have been completed in the course of our supply. In this way the specific
properties stipulated in the customer specification can also be checked, and met. In conjunction
with external institutes, we have also completed detailed measurements for the following areas:

EMV Electromagnetic tolerance in conjunction with Systron EMV Ltd., Rednitzhembach.


Fire gas analysis or low temperature carbonization gas analysis of components of cast resin
transformers in conjunction with the Allianz Centre for Technology, Munich.
Vibration test in conjunction with IABG, Munich.
Short circuit strength in conjunction with KEMA.
Certification for -50 C in conjunction with Standard Elektro, Moscow.
E2 and C2 tests in conjunction with KEMA.
Full Routine, Type & Special Test as per IEC 60076-11 with KEMA.
14
Technical Data of Dry Type Cast Resin Transformer
Technical Data / Specifications
22 kV.
Capacity No-load Load Total Impedance Effciency Voltage Noise Outline Dimension Total Material
(kVA.) Loss Loss Loss at 75C P.F. = 1 Regulation Level Approx. (mm.) Weight H.V. / L.V.
(W) at 75C at 75C (%) P.F. = 1 (%) dB(A):1m. (kgs.) Winding
(W) (W) 1/2 Load (%) Full Load (%) H L W
1000 2650 9600 12250 6 99.00 98.79 1.14 59 2005 1580 980 2385 AL/AL
1250 3100 11800 14900 6 99.04 98.82 1.12 60 2095 1660 980 2715 AL/AL
1600 3500 14000 17500 6 99.13 98.92 1.05 61 1985 1960 980 3275 AL/AL
2000 4500 17000 21500 6 99.13 98.94 1.03 64 2025 2080 1270 3955 AL/AL

24 kV.
Capacity No-load Load Total Impedance Effciency Voltage Noise Outline Dimension Total Material
(kVA.) Loss Loss Loss at 75C P.F. = 1 Regulation Level Approx. (mm.) Weight H.V. / L.V.
(W) at 75C at 75C (%) P.F. = 1 (%) dB(A):1m. (kgs.) Winding
(W) (W) 1/2 Load (%) Full Load (%) H L W
1000 2650 9600 12250 6 99.00 98.79 1.14 59 1845 1760 980 2450 AL/AL
1250 3100 11800 14900 6 99.04 98.82 1.12 60 1935 1840 980 2780 AL/AL
1600 3500 14000 17500 6 99.13 98.92 1.05 61 2125 1900 980 3170 AL/AL
2000 4500 17000 21500 6 99.13 98.94 1.03 64 2095 2060 1270 4130 AL/AL

12/24 kV.
Capacity No-load Load Total Impedance Effciency Voltage Noise Outline Dimension Total Material
(kVA.) Loss Loss Loss at 75C P.F. = 1 Regulation Level Approx. (mm.) Weight H.V. / L.V.
(W) at 75C at 75C (%) P.F. = 1 (%) dB(A):1m. (kgs.) Winding
(W) (W) 1/2 Load (%) Full Load (%) H L W
1000 2650 9600 12250 6 99.00 98.79 1.14 59 1740 1695 980 2525 CU/AL
1250 3100 11800 14900 6 99.04 98.82 1.12 60 1855 1820 980 2900 CU/AL
1600 3500 14000 17500 6 99.13 98.92 1.05 61 1940 2020 980 3485 CU/AL
2000 4500 17000 21500 6 99.13 98.94 1.03 64 2090 2140 1270 4420 CU/AL
*Technical Data / Specifications are subject to change without notice.
Manufacturing range
Cast Resin Transformers up to and including 25 MVA
and service voltage up to 36 kV.
Sole Distributor :

Charoenchai Energy Company Limited


32 Soi Prachautis 21, Bang Mod,
Thungkru, Bangkok 10140, Thailand.
Tel : (662) 870 9866 (Auto 20 lines)
Fax : (662) 870 9119
E-Mail : [email protected]
www.charoenchai-energy.com

Manufactured by

AM SGB SDN. BHD. (Malaysia) STARKSTROM GERTEBAU GMBH (Germany)


PT 16688 & 16689, Jalan Permata 2, Ohmstrae 10, D-93055 Regensburg, Germany.
Arab-Malaysian Industrail Park, 71800 Nilai, Tel : +49 (0)941 / 7841-0
Negeri Sembilan. Fax : +49 (0)941 / 7481-439
Tel : 06-799 4014 / 799 4016 / E-Mail : [email protected]
799 5996 / 799 5998 www.sgb-trafo.de
Fax : 06-799 4946 / 799 4018
E-Mail : [email protected]
www.sgb-smit.com

You might also like