Liebert NXC Brochure 10kva To 40kva

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

NXCTM UPS

10kVA - 60kVA
Reliable & Scalable power system
designed for Small and Mid-size Enterprises
WE ARE VERTIV

Vertiv, formerly Emerson Network Power, designs, builds ,and services mission critical
technologies that enable vital applications for data centers, communication networks,
and commercial & industrial environments.

We support today's growing mobile and cloud computing markets with our portfolio of
power, thermal and infrastructure management products, software and solutions, all
complemented by our extensive global service network.

We help strengthen the world's most vital applications by bringing together global
reach and local knowledge, and our decades-long heritage, including brands like
ASCO, Chloride, Liebert, NetSure, and Trellis.

Vertiv vice & Consultatio


S er n
Your Vision, our Passion Software

nfrastru
With a unique combination if ie d I ct
Un ur
of industry expertise,
technology, and resources, Thermal Power e
Management Management
our mission is to support
and power mission-critical IT
Management
technologies that drive
possibility.

Our global critical Our global Our global power Our global Our industry-
power switching, industrial power and thermal intelligently leading software
control, and solutions meet the management engineered DC gives customers an
management most demanding solutions are some power systems integrated view of
solutions, engineered technical of the worlds most deliver high operations across
to the most specifications and efficient and availability, energy IT and facilities
demanding provide safe, reliable power and efficiency, and resources,
specifications, reliable power- no cooling scalability for enabling better
ensures power, matter the technologies converged decisions that save
reliability, challenge networks time and money
compliance and
efficiency
Features and Performances Compact, Reliable Power

Double conversion efficiency Liebert NXCTM offer reliable and power for a wide range of
up to 95.5% flexible secure power in a fully applications from IT and light
integrated package solution. It industrial to retail and transport.
comes complete with highly
ECO mode efficiency up to efficient transformer-free double Liebert NXC TM achieves up to
99% conversion technology providing 95.5% efficiency in double
installation and running cost conversion mode and up to 99%
Input current total harmonic savings. in ECO mode ensuring effective
distortion correction load protection while reducing
(THDi)<5% With a rated output power factor of the total cost of ownership (TCO)
0.9, Liebert NXCTM is also able to and environmental impact.
Input/output and bypass provide 10% more active power
circuit breakers than a traditional mid-size UPS.
Liebert NXCTM combination of
performance features, impressive
Integrated manual bypass
integrated autonomy and compact
footprint make it ideal for
Integrated parallel load bus guaranteeing clean, continuous
and synchronization port
(LBS)

Integrated Battery autonomy

Maintenance Bypass
Bypass static switch

Bypass
Input Rectifier Inverter Fuse
Output
Fuse Fuse Load
Booster/Battery charger

Battery Fuse

Internal Battery

External Battery

Liebert NXCTM Single-line diagram


LIEBERT NXC T M UPS

Configuration available
Flexibility
1. UPS with integrated battery Liebert NXCTM is a compact Output Configuration
2.UPS with integrated solution designed to optimize Liebert NXCTM can be configured
isolation transformer installation space requirements on-site to deliver three(3/3) or
and provide enhanced flexibility to single (3/1) phase output giving it
ensure superior protection for all the flexibility to adapt to change
load types (leading and lagging).
in dynamic environments.

Its low THDi (<5%) and active


input power factor correction Full Galvanic Isolation
ensure that the UPS absorbs less Liebert NXCTM offer integrated
current from the upstream full galvanic isolation, this greatly
distribution net work, thus reduces the footprint thus
eliminating the need for over providing space saving
sizing gensets and other
advantages. In addition, the
equipment.
transformer can be connected to
UPS with fully integrated battery
the input/output/bypass of the
Everything from installation and UPS.
electrical infrastructure
requirements to energy
consumption and real estate Providing:
costs have been taken in to Full galvanic isolation for
consideration to deliver this
medical and other critical
flexible solution.
applications
Installation with two
Liebert NXC TM flexibility is independent input sources
further enhanced through: (with different neutrals)

Full galvanic isolation option


Single and three phase
output configuration
options
UPS with integrated Common or distributed
isolation transformer
battery bank
Reduced footprint
In The Field
Integrated autonomy
Liebert NXCTM provides an 1
excellent integrated autonomy
which results in back up times of
2 3
up to 30mintues.

The batteries housed inside the


UPS cabinet which are responsible
for delivering Liebert NXCTM s
integrated autonomy have the
added advantage of virtually
eliminating the need for an 4
external battery cabinet, further
reducing installation costs and
minimizing the demand on
physical space.

The powerful battery charger of


the Liebert NXCTM allows the 5
reduction of battery re-charging
time and increased its ability to
manage longer back up times.

Parallel Ready
Liebert NXCTM can be connected
with up to four units in parallel, one
of which is redundant. A single unit Transformer or Internal
1 Communication Slots 4
can be upgraded to parallel battery option
operation to modify software
settings which allow the system to 2 Power Module 5 Switch assembly
be customized for the requested
configuration. 3 LCD display interface
The Loop Bus connection used in
paralleling the system delivers
ultimate reliability by avoiding a
single point of failure probability,
ensuring perfect load sharing and
fast detection of any variation in
the system status.
LIEBERT NXC T M UPS

Serviceability
Communication The architecture of the Liebert NformTM is designed to optimize installation
The Liebert NXCTM features a and simplify service with its easily power assembly. This architecture allow
multi-lingual LCD user optimized MTTR & Maximize MTBF
Liebert NXC also comes equipped with casters to facilitate ease of ease of
TM
interface allowing close
control and monitoring of movement and relocation.
system status and
performance.
Software Connectivity
Liebert MultilinkTM software prevents unexpected server shutdowns and
The UPS offers the following
minimized downtime warning of pendingACP-EN-AP-7-1-0-17-3 power losses and
communication features:
initiating safe shutdown of operating systems if required.
Voltage-free contacts
USB interface
Liebert NformTM and Site Monitor network communications system enables
Internal Intellislot for SNMP
customers to leverage the distributed monitoring capabilities of network
or Modbus communication
connected equipment providing centralized management of distributed
systems.
These communication
capabilities make Liebert
NXCTM compatible with any
building management system.

Connectivity cards
Specifications

Nominal Ratings(kVA/kW) 10 15 20 30 40 60

Output active power 9 13.5 18 27 36 54


Input
Nominal input voltage(V) 380/400/415
Input voltage range(V) 305~477 at full load; 228-477 at 70% load
Nominal input frequency(Hz) 50/60
Input frequency range(Hz) 40-70
Input power factor(kW/kVA) 0.99
Bypass voltage tolerance(%) selectable from +20 to -40
Bypass frequency tolerance(%) 20 (10 selectable)
Current THD at full linear load(THDi%) <5
Battery
Number battery blocks per string 30-40
Battery Charger max. power (kW) 4.5 4.5 4.5 6 6 7.5
Output
380/400/415
Nominal output voltage (V) 380/400/415 (3-phase) or 220/230/240 (1-phase)
(3-phase)
Nominal output frequency (Hz) 50/60
THDv with 100% linear load (%) 2
Inverter overload capacity <105% Continuous; 125% for 5 min; 150% for 1 min
Efficiency
Online mode efficiency Up to 95.5%
ECO mode efficiency Up to 99%

Dimensions and weight


Dimensions (W x D x H) mm 500 x 860 x 1240 600 x 850 x 1600
Weight(Net weight) 115 210 225

General
Nosie at 1 m dB (A) 56 58 60
Protection level IEC (60529) IP20
General and safety
EN/IEC/AS 62040-1
requirements for UPS
EMC requirements for UPS EN/IEC/AS 62040-2
UPS classification according to
IEC 62040-3 VFI-SS-111

*Conditions apply
Specifications are subject to change without any prior notification
2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners.
While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions.
Specications are subject to change without notice.

ACP-EN-AP-2-1-0-17-3

You might also like