Relay Socket Family
Relay Socket Family
Relay Socket Family
Signaling Lights
RH Series Compact Power Relays................. 773
RR Series Power Relays................................. 783
RU Series Universal Relays........................... 790
RY/RM Series Miniature Relays.................... 799
RF1V Force Guided Relays............................. 810
Relays
Timers
Contactors
Terminal Blocks
www.IDEC.com/relays
Circuit Breakers
Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg. 933
Selection Guide Relays & Sockets
Selection Guide
Switches & Pilot Lights
Appearance
Signaling Lights
Appearance
754 www.IDEC.com
Relays & Sockets Selection Guide
Appearance
Signaling Lights
Page 759 790
Contact Configuration DPDT 4PDT
Terminal Blade or PCB Blade or PCB
Contact Rating
1A 250V AC/30V DC 3A 250V AC/30V DC
(resistive)
Contact Material Gold clad Gold Silver Alloy on Silver
Latching Relays
Appearance
Timers
Terminal Pin Blade
Contact Rating 10A, 30V DC 3A, 30V DC
(resistive) 10A, 240V AC 3A, 240V AC
Contact Material Silver Silver, gold-plated
Contactors
Appearance
Terminal Blocks
Page 819 822
Output Configuration 1 Form A (SPST-NO) 1 Form A (SPST-NO)
20A, 30A, 45A 10A, 25A, 50A, 75A, 90A
Output Rating
48 - 600V AC 48 - 660V AC
Output Dual SCR (zero crossing)
Circuit Breakers
Key features:
Space-saving 6mm width
Only 70mm in height from DIN rail
Gold-plated contacts
Pre-assembled relay and DIN mount socket
Universal screw terminals (flat and Phillips)
Spring clamp terminals
Universal AC/DC socket with built-in surge suppression and green LED
Lever for easy locking and removal of relay
Signaling Lights
RoHS compliant
Part Numbers
Relays & Sockets
Vertical Orientation
SV9Z-PW10-j11-20 11-20
6V RV8H-L-D6 RV8H-S-D6 Blue SV9Z-J20S
SV9Z-PW10-j21-30 21-30
9V RV8H-L-D9 RV8H-S-D9 Spacer (circuit separator)2
SV9Z-PW10-j31-40 31-40
DC 12V RV8H-L-D12 RV8H-S-D12 SV9Z-PW10-j41-50 41 -50
SV9Z-SA2W
18V RV8H-L-D18 RV8H-S-D18 SV9Z-PW10-j51-60 51-60
Timers
Horizontal Orientation
24V RV8H-L-AD24 RV8H-S-AD24 SV9Z-PW10-j91-100 91-100
AC/ SV9Z-PW10-jA-J A-J
48V RV8H-L-AD48 RV8H-S-AD48
DC 1. Jumper combs come with 20 points, if shorter lengths are
60V RV8H-L-AD60 RV8H-S-AD60 needed simply cut off the excess points. SV9Z-PW10-jK-T K-T
2. Width of spacer: 2mm
110V - 125V RV8H-L-AD110 RV8H-S-AD110 SV9Z-PW10-jU-Z U-Z
Note: When using a cut jumper, please use a spacer on the cut
Contactors
220V - 240V RV8H-L-AD220 RV8H-S-AD220 side. For additional information see instruction sheet. SV9Z-PW10-jGROUND GROUND
Replacement Parts
Complete Part Applicable Socket Applicable Relay Complete Part Applicable Socket Applicable Relay
Number Part Number Part Number Number Part Number Part Number
RV8H-L-D6 RV1H-G-D5 RV8H-S-D6 RV1H-G-D5
Terminal Blocks
756 www.IDEC.com
Relays & Sockets RV8H
Specifications
Signaling Lights
Vibration NC: Frequency 10 to 55Hz, Amplitude 0.4mm
Resistance NO: Frequency 10 to 55Hz, Amplitude 0.5mm
Damage limits
NC: Frequency 10 to 55Hz, Amplitude 0.2mm
NO: 49m/s2 (5G)
Shock Operating extremes
NC: 29.4m/s2 (3G)
Resistance
Damage limits 980m/s2 (10G)
Mechanical Life (without load) Over 10,000,000 operations
-40 to +70C without freezing
Operating Temperature (-40 to +55C for RV8H-L-AD110, AD220,
Coil Ratings
Circuit Circuit Operating Characteristics
Rated Current Power
Rated Voltage AC Resistance DC Resistance Pickup Dropout Maximum
+-15% (mA) Consumption
+-10% () +-10% () Voltage Voltage Allowable voltage
Timers
6V 35 - 170 0.21W
9V 18.6 - 485 0.2W
DC 12V 14.6 - 820 110% 0.2W
18V 11.6 - 1550 0.2W
24V 10.6 - 2270 0.25W
12V 15.5 755 800 0.2W
90% max 7% min
18V 13.3 1365 1345 0.25W
Contactors
24V 13.7 1730 1790 0.33W
AC/DC 48V 4 11880 12230 110% 0.2W
60V 3.4 17600 17910 0.2W
110V - 125V 3.4 - 3.9 31790 - 31890 32450 - 32900 0.5W
220V - 240V 3.3 - 3.6 65670 - 66070 65940 - 68570 0.85W
RV1H Relay
Terminal Blocks
Contact Ratings Maximum Switching Power AC Maximum Switching Power DC
DC Resistive load
Circuit Breakers
DC Inductive load
(L/R = 56ms)
Dimensions (mm)
Switches & Pilot Lights
A1(+) Coil 14 NO
15.0
69.6
Signaling Lights
74.2
0.5
11 (13+) COM
A2(-) Coil
3.5
1.2 0.5 1
5 0.9 5.04 5.04
3.78 16.38 12 NC
35 6.1
Note: Drawings are not to scale.
88
Relays & Sockets
A1 A2 12 11 14
(13+)
14 NO
A1(+) Coil
66.8
71.4
11 (13+) COM
A2(-) Coil
Contactors
12 (NC)
35
96.7 2
16.5
10.5
,QVHUW
1 6 59+
86.5
SV9Z-J20*
115.9
6.1
6
12.3
Circuit Breakers
120 2.8
758 www.IDEC.com
Relays & Sockets RJ
Signaling Lights
Excellent electrical and mechanical life.
Electrical life: 200,000 operations (AC load)
Mechanical life: 30 million operations (AC coil)
RoHS directive compliant (EU directive 2002/95/EC). Contains no lead, cadmium, mercury, hexavalent chromium, PBB or PBDE.
Diode model:
Diode reverse withstand voltage: 1000V
UL recognized, CSA certified, EN compliant.
Timers
with Surge Suppresion Diode RJ1S-CD-0
D12, D24, D48, D100
with LED & Surge Suppresion Diode RJ1S-CLD-0
Standard RJ2S-C-0 A24, A110, A120, A220, A240,
with LED RJ2S-CL-0 D12, D24, D48, D100
Blade
with Surge Suppresion Diode RJ2S-CD-0
D12, D24, D48, D100
with LED & Surge Suppresion Diode RJ2S-CLD-0
DPDT
Contactors
Standard Bifurcated contacts (without LED indicator) RJ22S-C-0 A12, A24, A120, A240,
Bifurated contacts (with LED indicator) RJ22S-CL-0 D5, D12, D24, D100
Terminal Blocks
A24, A110, A120, A220, A240,
SPST-NO
High Capacity RJ1V-AH-0 D5, D6, D12, D24, D48, D100
PCB
DPDT Standard RJ2V-C-0
DPST-NO Standard RJ2V-A-0
DPDT Bifurcated contacts RJ22V-C-0 A12, A24, A120, A240,
DPST-NO Bifurcated contacts RJ22V-A-0 D5, D12, D24, D48, D100
Ordering Information
Circuit Breakers
When ordering, specify the Part No. and coil voltage code:
(example) RJ1S-C- A120
Part No. Coil Voltage Code
Coil Voltage Code A12 A24 A110 A120 A220 A240 D5 D6 D12 D24 D48 D100
Coil Rating 12V AC 24V AC 110V AC 120V AC 220V AC 240V AC 5V DC 6V DC 12V DC 24V DC 48V DC 100-110V DCV DC
SJ9Z-CM
Blade
SJ2S-05BW, SJ2S-07LW
RJ2S (Std)/RJ22S SJ2S-05BW SJ2S-07LW SJ2S-61 SQ9Z-C SQ1V-07B, SQ2V-07B
Signaling Lights
10
Shown with optional marking plate.
Accessories
Item Appearance Use with Part No. Remarks
The BNDN1000 is designed to accommodate DIN mount sockets.
Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).
Timers
Marking Plate Finger safe sockets (ONLY) SJ9Z-PWPN10 10 pieces per pack
Contactors
Terminal Blocks
Circuit Breakers
760 www.IDEC.com
Relays & Sockets RJ
Specifications
Signaling Lights
Release Time 2 10 ms maximum (with diode: 20 ms maximum)
Between contact and coil 5000V AC, 1 minute
Dielectric
Between contacts of the same pole 1000V AC, 1 minute
Strength
Between contacts of different poles 3000V AC, 1 minute
Vibration Operating extremes 10 to 55 Hz, amplitude 0.75 mm
Resistance Damage limits 10 to 55 Hz, amplitude 0.75 mm
Shock Operating extremes NO contact: 200 m/s2, NC contact: 100 m/s2
Timers
19g (blade type), 17g (PCB form C type),
Weight (approx.) 19g DPDT: 17g, DPST-NO: 16g
16g (PCB form A type)
Contactors
Terminal Blocks
Circuit Breakers
Coil Ratings
Switches & Pilot Lights
Approx.
Bifurcated 24V A24 43.9 37.5 47.5 41.1 243 1.1VA (50Hz)
Signaling Lights
Models 120V A120 8.8 7.5 8.7 7.4 6,400 0.9 to 1.2VA
240V A240 4.3 3.7 4.3 3.7 25,570 (60Hz)
Rated Current (mA) Coil
Coil Operating Characteristics2
15% (at 20C) Resistance Power
Rated Voltage Voltage
(ohms)10% Pickup Dropout Maximum Consumption
Coil Ratings
Contact Ratings
Allowable Contact Power Rated Load Allowable Allowable Minimum
Model Contact Resistive Resistive Inductive Load Switching Switching Applicable
Contactors
Contact Ratings
NO 12A
Standard 360W 180W 30V DC 12A 6A AC250V DC5V
Type 3000V AC 1875VA 250V AC 12A 7.5A DC125V 100mA
NC 6A
180W 90W 30V DC 6A 3A
1 pole
4000V AC 2000VA 250V AC 16A 8A
High NO 16A
480W 240W 30V DC 16A 8A AC250V DC5V
PCB Models
Capacity
4000V AC 2000VA 250V AC 16A 8A DC125V 100mA
Type NC 8A
240W 120W 30V DC 8A 4A
2000V AC 1000VA 250V AC 8A 4A
NO 8A
Circuit Breakers
762 www.IDEC.com
Relays & Sockets RJ
Agency Ratings
CSA
Signaling Lights
General Use Resistive Inductive
Voltage
RJ22 RJ1 RJ2 RJ22 RJ1 RJ2 RJ22
NO NC NO NC NO NC NO NC NO NC NO NC NO NC
250V AC 1A 1A 12A 12A 8A 8A 7.5A 7.5A 4A 4A
30V DC 12A 6A 8A 4A 1A 1A 6A 3A 4A 2A 1A 1A
VDE
Resistive AC-15, DC-13*
Socket Specifications
Socket Terminal Electrical Rating Wire Size Torque
Timers
0.6 - 1.0Nm
SJ1S-05BW M3 screw with captive wire clamp 250V, 12A Maximum up to 2 - #14 AWG
DIN Rail/ (Maximum 1.2Nm)
Panel Mount 0.6 - 1.0Nm
SJ2S-05BW M3 screw with captive wire clamp 250V, 8A Maximum up to 2 - #14 AWG
(Maximum 1.2Nm)
0.6 - 1.0Nm
SJ1S-07LW M3 screw with captive wire clamp, fingersafe 250V, 12A Maximum up to 2 - #14 AWG
(Maximum 1.2Nm)
Finger-safe 0.6 - 1.0Nm
DIN Rail/Panel SJ2S-07LW M3 screw with captive wire clamp, fingersafe 250V, 8A Maximum up to 2 - #14 AWG
(Maximum 1.2Nm)
Mount
Contactors
SQ1V-07B M3 screw with box clamp, fingersafe 300V, 12A Maximum up to 2 - #14 AWG 1.0Nm Maximum
SQ2V-07B M3 screw with box clamp, fingersafe 300V, 10A Maximum up to 2 - #14 AWG 1.0Nm Maximum
SJ1S-61 PCB mount 250V, 12A
SJ2S-61 PCB mount 250V, 8A
PCB Mount
SQ1V-63 PCB mount 300V, 12A
SQ2V-63 PCB mount 300V, 12A
Terminal Blocks
Circuit Breakers
( 10,000 operations)
( 10,000 operations)
250V AC 250V AC 250V AC
Resistive Load Resistive Load Resistive Load
100 (NO contact) 100 (NO contact) 100 (NO contact)
1 1 1
0.1 1 12 0.1 1 16 0.1 1 8
Load Current (A) Load Current (A) Load Current (A)
10 10 10
DC Resistive
(NO Contact)
DC Inductive
DC Resistive (NO Contact) (NC Contact)
DC Resistive (NO Contact)
0.1
0.1 1 10 100 250
0.1
1 10 100 250 1 10 100 250
Load Voltage (V) Load Voltage (V)
Load Voltage (V)
RJ1 (AC Coil, 60 Hz) RJ1 (AC Coil, 50 Hz) RJ1 (DC Coil)
AC Coil (60 Hz) AC Coil (50 Hz) DC Coil
130 130 130
120 120 120
110 110 110
100 100 100
Temperature Rise (C)
90
Temperature Rise (C)
90 90
Temperature Rise (C)
80 80 80
Load Current 12A 1 pole Load Current 12A 1 pole
70 70 70
Contactors
RJ2 (AC Coil, 60 Hz) RJ2 (AC Coil, 50 Hz) RJ2 (DC Coil)
Terminal Blocks
80 80 80
70 70 Load Current 8A 2 poles 70
60 60 60
50 Load Current 8A 2 poles 50 50 Load Current 8A 2 poles
40 40 40
30 30 No Load Current 30
20 No Load Current 20 20 No Load Current
Circuit Breakers
10 10 10
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)
764 www.IDEC.com
Relays & Sockets RJ
Rise (C)
(C)
Rise (C)
(C)
Rise (C)
(C)
90 90
90 90 90
90 90 90
90
80 80
80 80 80
80 80 80
80
Temperature Rise
Temperature Rise
Temperature Rise
70 70
70 70 70
70 70 70
70
Temperature
Temperature
Temperature
60 60
60 60 60
60 60 60
60
50 50
50 50 50
50 50 50
50
40 40
40 40 40
40 40 40
40
30 30 Load current
30 1A x 2 1A
Loadcurrent
Load current poles
1Axx22poles
poles 30 30 Load current
30 Loadcurrent
Load current
1A x 2 1A
poles
1Axx22poles
poles 30 30
30
20 20 No loadNo
20 current
No loadcurrent
load current 20 20 No loadNo
20 No
current
loadcurrent
load current 20 20
20 Load current
Loadcurrent
Load current 1Axx22poles
1A x 2 1A
poles poles
Signaling Lights
10 10
10 10 10
10 10 10
10 No loadNo
No loadcurrent
current
load current
0 0010 20
10 30
10 20 40
20 30 50
30 40 60
40 50 70
50 60 70
60 70 0 0010 2010 20
10 3020 4030
30 5040 50
40 60
50 7060
60 70
70 0 0010 2010 30
10 20 40
20 30 50
30 40 60
40 50 70
50 60
60 70
70
Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
(C) (C)
(C) Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
(C) (C)
(C) Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
(C) (C)
(C)
The above temperature rise curves show characteristics when 100% the rated coil voltage is applied.
The slanted dashed line indicates allowable temperature rise for the coil at different ambient temperatures.
Timers
5 5 8 8
(A2) (A2) (A2) 7(22) 6(21) 5(24) (A2) 7(22) 6(21) 5(24)
Coil voltage 24V AC/DC and below Coil voltage greater than 24V AC/DC Coil voltage 24V AC/DC and below Coil voltage greater than 24V AC/DC
Contactors
(A2) (A2)
RJ1-CLD-* With LED Indicator and Diode RJ2-CLD/ RJ22-CLD-* With LED Indicator and Diode
1 1 1 1
(A1) (A1) (A1) (A1)
2(12) 3(11) 4(14) 2(12) 3(11) 4(14)
2(12) 4(11) 3(14) 2(12) 4(11) 3(14)
5 + 5 + 8 + 8 +
(A2) (A2) (A2) 7(22) 6(21) 5(24) (A2) 7(22) 6(21) 5(24)
Coil voltage 24V DC and below Coil voltage greater than 24V DC Coil voltage 24V DC and below Coil voltage greater than 24V DC
Terminal Blocks
Circuit Breakers
Dimensions (mm)
Switches & Pilot Lights
27.0
28.0
27.0
6.0
5.0
ole
4.8 4.8
3h
le
ho
31.1
31.1
3
.2
1
Relays & Sockets
.8
1
4
2
1
1
12.7
12.7
0.5
2
3
5
5
7
28.8 28.8
All dimensions in mm.
5- 5 hol h
1.3 -1.3 es oles
25.5 max. (25.3)
(2.6)
(2.6)
7.5
7.5
(2.6)
(2.6)
7.5
7.5
0.3
0.3
0.3
0.3
0.5 0.5 0.5 0.5 (1.9) (1.9) 20.0 20.0 3.5 3.5
1.0 1.0 0.5 0.5
0.3 0.3 0.5 0.5 (1.9) (1.9) 20.0 20.0 0.3 0.3 0.5 0.5 1.0 1.0
4.0
4.0
13 max.
13 max.
13 max.13 max.
4.0
4.0
29 max.
29(28.8)
max. (28.8) (12.7) (12.7) 29 max.29(28.8)
max. (28.8) (12.7) (12.7)
RJ1V-CH-*/RJ2V-C-* RJ1V-AH-*/RJ2V-A-*
Contactors
6- 6-
1.3 1.3
hol hol
es es
25.5 max. (25.3)
8- 8
1.3 -1.3 5.0 5.0 5.0 5.0
hol h
es oles
(2.6)
(2.6)
7.5
7.5
(2.6)
(2.6)
7.5
7.5
0.3
0.3
0.3
0.3
4.0
13 max. 13 max.
4.0
4.0
29 max.
29(28.8)
max. (28.8) (12.7) (12.7) 29 max. (28.8) (12.7) (12.7)
29 max. (28.8)
Terminal Blocks
RJ22V-C-* RJ22V-A-*
25.5 max.
25.5 max.
(25.3)
(25.3)
0.3
0.3
4.0
766 www.IDEC.com
Relays & Sockets RJ
15.5
6
6
Signaling Lights
55.7
55.7
29.7
29.7
4.3 71 4 4.3 71 4
2
2
(22) (24)
5 (A2) 3 (14) 8 7 5 6
(A2) (21)
(A1) (A1) (11)
1 2
(12) (11) 4 1 2
(12) (14)
4 3
5.6 5.6
15.5
15.5
55.7
55.7
49.5
49.5
35.5
35.5
29.7
29.7
Timers
21.5
21.5
4.3 71 3 4.3 71 3
2
2
(A2) (21)
5 (A2) 3 (11) 4 8 5 7 6
(14) (24) (22)
(14) (12)
1 (A1) 2 (12) 1 4 2 3
(A1) (11)
(TOP VIEW) (TOP VIEW)
Contactors
SQ1V-07B SQ2V-07B
Terminal Blocks
Circuit Breakers
A2
11 A2 24 21 22
A1 14 12
A1 14 11 12
(TOP VIEW)
(TOP VIEW)
PC Mount Sockets
SJ1S-61 SJ2S-61
32.5 32.5
(4.3) 20.0 0.1
(4.7) 4.5 0.1 6.0 0.1 5.0 0.1 5.0 0.1
4.0 0.1
14.0
14.0
Terminal Arrangement
Terminal Arrangement
7.0 0.1
(Bottom View)
7.5 0.1
(Bottom View)
1 2 3 1 2 3 4
5 4
8 7 6 5
4.0 0.1 15.0 0.1
5-
8-
1
1
Signaling Lights
.6
.3
36.5
ho
ho
36.5
les
les
1.0
1.0
4.0
4.0
SQ1V-63 SQ2V-63
Relays & Sockets
Timers
Contactors
Terminal Blocks
Circuit Breakers
768 www.IDEC.com
Relays & Sockets RQ
Signaling Lights
High capacity model with 16A (SPDT) contact rating
Operational life:
100K cycles at full resistive load
10 million cycles, no load
LED/Diode Plug-in modules available with DIN rail socket
UL Recognized
File No. E59804
Timers
Basic RQ1V-CM-0 A24, A115, A230, D12, D24
SPDT 16A
HIgh Capacity (HC) RQ1V-CH-0 A24, A115, A230, D12, D24, D110
Contactors
DPDT 8A
Terminal Blocks
Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RQ1V-CM A115
Part No. Coil Voltage Code
Circuit Breakers
Accessories
Item Appearance Use with Part No. Remarks
IDEC offers a low-profile DIN rail (BNDN1000). The BNDN1000 is de-
Aluminum
signed to accommodate DIN mount sockets. Made of durable extruded
DIN Rail All DIN rail sockets BNDN1000
aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37
Relays & Sockets
(1 meter length)
(35mm) in width (DIN standard). Standard length is 39 (1,000mm).
Specifications
Model (Contact) RQ1 RQ1 HC RQ2
No. of poles 1 1 2
Timers
770 www.IDEC.com
Relays & Sockets RQ
Coil Ratings
Signaling Lights
230V 3.42mA 2.72mA 32,500 0.79W 0.63W
Socket Specifications
Relays Terminal Electrical Rating Wire Size Torque
SQ1V-07B M3 screw with box clamp 300V, 12A Maximum up to 2 - #14 AWG 1.0Nm Maximum
DIN Rail Sockets
SQ2V-07B M3 screw with box clamp 300V, 8A Maximum up to 2 - #14 AWG 1.0Nm Maximum
SQ1V-63 PCB mount 300V, 12A
PCB Mount Socket
SQ2V-63 PCB mount 300V, 12A
10 7 10 7 300
200
Timers
Oper at i ons
Oper at i ons
RQ2V-CN Dimensions 50
RQ1V-CM Dimensions RQ1V-CH Dimensions 40
10 5 10 5 30
20
RQ2
RQ1 RQ1-HC RQ1
RQ1-HC
10 4 10 4 10
0 2 4 6 8 10 12 14 16 0 2 4 6 8 10 12 14 16 0.1 0.2 0.5 1 2 5 10 20
Load Current (A) Load Current (A) Load Current (A)
Contactors
Internal Connection (View from Bottom)
RQ1 RQ2 RQ1 HC
NC C NO
NC NC C
NO
C NC C NO NO
Terminal Blocks
Bottom View Bottom View
Bottom View
Bottom View
View Bottom View
Circuit Breakers
Dimensions (mm)
Switches & Pilot Lights
RQ1 RQ2/RQ1 HC
Signaling Lights
SQ Socket Domensions
SQ1V-07B SQ2V-07B
Relays & Sockets
Timers
A2 24 21 22
A2
11
A1 14 12 A1 14 11 12
SQ1V-63 PCB Pin Layout SQ1V-63 SQ2V-63 PCB Pin Layout SQ2V-63
Terminal Blocks
Circuit Breakers
772 www.IDEC.com
Relays & Sockets RH
Signaling Lights
Part Number Selection
Part Number
Blade PCB Termi- Coil Voltage Code
Contact Model
Terminal nal (Standard Stock in bold)
Standard RH1B-U 0 RH1V2-U 0
Timers
AC6V, AC12V, AC24V, AC110-120V,
With Check Button RH2B-UC 0 AC220-240V
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Check Button RH2B-ULC 0
Top Bracket Mounting RH2B-UT 0
With Diode (DC coil only) RH2B-UD 0 RH2V2-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RH2B-ULD 0 RH2V2-ULD 0
Standard RH3B-U 0 RH3V2-U 0
Contactors
3PDT
With Indicator RH3B-UL 0 RH3V2-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH3B-UC 0 AC220V, AC240V DC6V, DC12V, DC24V,
DC48V, DC110V
With Indicator and Check Button RH3B-ULC 0
Top Bracket Mounting RH3B-UT 0
With Diode (DC coil only) RH3B-UD 0
DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH3B-ULD 0
Terminal Blocks
Standard RH4B-U 0 RH4V2-U 0
4PDT
With Indicator RH4B-UL 0 RH4V2-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH4B-UC 0 AC220V, AC240V DC6V, DC12V, DC24V, DC48V,
DC110V
With Indicator and Check Button RH4B-ULC 0
Top Bracket Mounting RH4B-UT 0
With Diode (DC coil only) RH4B-UD 0 RH4V2-UD 0
DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH4B-ULD 0
Circuit Breakers
PCB terminal relays are designed to mount directly to a circuit board without any socket.
Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RH3B-U AC120V
Part No. Coil Voltage Code
Relays Standard DIN Rail Mount 1 Finger-safe DIN Rail Mount 1 Through Panel Mount PCB Mount
RH1B SH1B-05 SH1B-O5C SH1B-51 SH1B-62
RH2B SH2B-05 SH2B-05C SH2B-51 SH2B-62 1. DIN Rail mount socket
comes with two
RH3B SH3B-05 SH3B-05C SH3B-51 SH3B-62 horseshoe clips. Do
not use unless you
RH4B SH4B-05 SH4B-05C SH4B-51 SH4B-62 plan to insert pullover
wire spring. Replace-
ment horseshoe
clip part number is
Y778-011.
Signaling Lights
Leaf Spring (side latch) RH1B, RH2B, RH3B, RH4B SFA-202 3 SFA-302 3
Leaf Spring (top latch) RH1B, RH2B, RH3B, RH4B SFA-101 3 SFA-301 3
AC Coil Ratings
Rated Current (mA) 15% at 20C Coil Resistance () Operation Characteristics
Timers
DC Coil Ratings
Terminal Blocks
774 www.IDEC.com
Relays & Sockets RH
Signaling Lights
1650VA 1100VA
3PDT 10A 220 AC 7.5A 5A
300W 225W Horse-
4PDT
30 DC 10A 7.5A Resistive General Use power
Note: Inductive load for the rated load cos = 0.3, L/R = 7 ms Voltage Rating
RH1 RH2 RH3 RH4 RH1 RH2 RH3 RH4 RH1, 2, 3
240V AC 10A 10A 7.5A 7A 7A 7A 5A 1/3 HP
TV Ratings 120V AC 10A 10A 10A 10A 7.5A 7.5A 7.5A 1/6 HP
Voltage RH1 RH2 RH3 RH4 30V DC 10A 10A 10A 10A 7A 7.5A
Socket Specifications
Sockets Terminal Electrical Rating Wire Size Torque
(Coil) M3 screws 5.5 - 9 inlbs
SH1B-05 250V, 10A Maximum up to 2#12AWG
DIN Rail (contact) M3.5 screws with captive wire clamp 9 - 11.5 inlbs
Timers
Mount SH2B-05
Sockets SH3B-05 M3.5 screws with captive wire clamp 300V, 10A Maximum up to 2#12AWG 9 - 11.5 inlbs
SH4B-05
(coil) M3 screws 5.5 - 9 inlbs
SH1B-05C 250V, 10A Maximum up to 2#12AWG
Finger-safe (contact) M3.5 screws with captive wire clamp, fingersafe 9 - 11.5 inlbs
DIN Rail SH2B-05C
Mount SH3B-05C M3.5 screws with captive wire clamp, fingersafe 300V, 10A Maximum up to 2#12AWG 9 - 11.5 inlbs
SH4B-05C
Through SH1B-51
Contactors
Panel SH2B-51
Solder 300V, 10A
Mount SH3B-51
Socket SH4B-51
SH1B-62 PCB mount 250V, 10A
PCB Mount SH2B-62
Socket SH3B-62 PCB mount 300V, 10A
SH4B-62
Replacement
DIN mount sockets and hold For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
down springs. spring. 2 pieces included with each socket.
Spring Anchor
Specifications
Switches & Pilot Lights
Release Time 2
3PDT
25ms maximum
4PDT
SPDT AC: 1.1VA (50Hz), 1VA (60Hz) DC: 0.8W
Power Consumption DPDT AC: 1.4VA (50Hz), 1.2VA (60Hz) DC: 0.9W
(approx.) 3PDT AC: 2VA (50Hz), 1.7VA (60Hz) DC: 1.5W
4PDT AC: 2.5VA (50Hz), 2VA (60Hz) DC: 1.5W
Insulation Resistance 100M minimum (500V DC megger)
Relays & Sockets
SPDT
Operating DPDT
25 to +70C (no freezing)
Temperature 4 3PDT
4PDT
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g
776 www.IDEC.com
Relays & Sockets RH
Signaling Lights
50 50
100V DC resistive
30V DC inductive
20 20
240V AC inductive 240V AC resistive
120V AC inductive 100V DC inductive
10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)
20 20
Timers
10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)
120V AC resistive
30V DC resistive
500 500
Life ( 10,000 operations)
30V DC inductive
Contactors
100 100
50 50
DC resistive
Load Current (A)
DC resistive
1.0 1.0
DC inductive
Circuit Breakers
0.1 0.1
1 5 10 50 100 200 300 1 5 10 50 100 200 300
Load Voltage (V) Load Voltage (V)
Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type)
Switches & Pilot Lights
(RH1) Note: The rated voltage is (RH2) Note: The rated voltage is (RH3/RH4) Note: The rated voltage is
applied to the coil. applied to the coil. applied to the coil.
100 100 100
90 90 90
Operating Temperature (C)
60 60 60
20 20 20
Signaling Lights
10 10 10
0 0 0
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A) Load Current (A)
Front
1 2 3 4 Pushbutton
5 6 7 8
9 10 11 12
Contacts can be operated by pressing the
13 () (+) 14 check button.
1 1 2 4 1 2 3 4 1 4
5 5 6 8 5 6 7 8 5 8
Below Below When the relay is energized,
Timers
9 9 10 12 9 10 11 12 9 12
100V 13 14 24V AC/ the indicator goes on.
() (+) 13 ( ) ( + )14 ( + )14
13( ) ( + )14 13( ) Relay coils less than 100V
AC/DC DC
DC do not contain a protec-
tion diode (except DPDT).
Relay coils below 100V
use LED indicator, coils
1 1 4
1 2 4 1 2 3 4 above 100V use neon lamp
5 5 8
100V 5 6 8 5 6 7 8 24V AC/ indicator.
9 9 12
AC/DC 9 10 12 9 10 11 12 DC and LED color of DPDT model
13 14 13 () (+) 14
and over over is green
Contactors
() (+) 13 () (+) 14
13( ) ( + )14
5 6 8 5 6 7 8
9 9 12 9 10 12 9 10 11 12 coil only.
13
()
14
(+)
13 () (+) 14
13 () (+) 14 13 () (+) 14 Diode Characteristics
Reverse withstand voltage: 1,000V
Forward current: 1A
Circuit Breakers
778 www.IDEC.com
Relays & Sockets RH
1
1 4
5
5 8
9 Below
Below 9 12
13 14 24V AC/
100V DC () (+) 13( ) ( + )14
DC
Contains an LED indicator and
a surge absorber, and has the
same height as the basic type.
Signaling Lights
1
1 4
LED color of DPDT model is
5
5 8 green.
9 24V AC/
100V DC 9 12
13 ( ) 14( + ) DC and
and over
over
13 14
() (+)
Dimensions (mm)
2.6 hole
4.7
2.6 hole
1 2.6 hole
4.7
5 1 4
27.5
9 5 8
0.5
27.5
0.5
9 12
13 14
13 14 1 2 4
5 6 8
Timers
27.5
5.4 14
0.5
9 10 11
10
Dimensions in the ( )
Contactors
include a hold-down spring. 2.6 hole
0.5
4.7
2.6 hole
4.7
0.5
4.7
1
5
1 4
5.9
43.2
27.5
9
38
5 8
5.9
43.2
27.5
38
13 14
9 12
13 14
2.6 hole
6.6
7.25
3.5 2 5.4
4.7
9 10 11 12
13 14
Terminal Blocks
35.6 max. 6.4 41
RH3B-UT RH4B-UT
10
10
4.7
10
10
10
3.5
Circuit Breakers
2.6 hole
4.7
2 3.5
0.5
4.7
2.6 hole
0.5
4.7
1 2 4
1 2 3 4
5.9
5 6 8
43.2
38
28
5.9
5 6 7 8
9 10 12
28
38
44
13 14 9 10 11 12
13 14
7.25
7.25
RH1V2-U/RH1V2-UD RH2V2-U/RH2V2-UL/RH2V2-UD
8-2.4 holes
0.5
4.7
3-2.4 holes
2-2 holes
7.25
0.5
1.5
4.7
0.5
2
7.15
0.5
1
13.15
5
7.8
1 4
27.5
9
12.5
0.5
5 8
27.5
6.6
13 14
9 12
13 14
5
35.6 max. 4.6 14 10
2
Signaling Lights
RH3V2-U/RH3V2-UL/RH3V2-D RH4V2-U/RH4V2-UL/RH4V2-UD
30
11-2.4 holes 10 10
4.7
14-2.4 holes 10
4.7
2
13.15
1 2 4
13.15
7.8
5 6 8
7.8
1 2 3 4
27.5
Relays & Sockets
9 10 11 5 6 7 8
0.5
27.5
9 10 11 12
0.5
13 14
13 14
7.25
7.25
0.5 31
0.5 41
35.6 max. 4.6
35.6 max. 4.6
4 1
4.2
16
67
47
26
67
47
20 25 30 25 3.6 min.
2.5
SH3B-05 SH4B-05
32
31.5 42 31.5
4 2 1
46
67
47
67
47
36
4.4 max. 5.5 min. 14 13
4.4 max. 5.5 min. 14 13
Terminal Blocks
12 11 10 9
12 10 9
(Top View)
(Top View) 46 14.5
36 14.5 7.9 max.
7.9 max. 50 25 3.6 min.
2.5
2.5
40 25 3.6 min.
Circuit Breakers
780 www.IDEC.com
Relays & Sockets RH
4.2
1
(or M4 Tapped Holes)
4.2
49
69
26
48
69
16
14 13
M3 Terminal
Signaling Lights
14 13 12 9
Screw
9
Ring terminals 18.7 Ring terminals (Top View)
26
16 18.7
cannot be used. (Top View) cannot be used.
1.7
30 29.5
20 29.5
1.7
SH3B-05C SH4B-05C
32 When using
M3.5 Terminal 36 42 BAA/BAP: 33
7 Screw DIN Rail
25 Terminal Arrangement 7 25
(BNDN)
DIN Rail
8 6 5 (BAA/BAP) Terminal Arrangement
5 2-4.2 Mounting Holes
4 2 1
(or M4 Tapped Holes)
4.2
49
69
36
49
69
14 13 46
12 10 9
14 13
36 18.7
cannot be used. Ring type crimping (Top View)
1.7
50 29.5
Timers
Contactors
SH3B-51 SH4B-51
Terminal Blocks
Circuit Breakers
6.95
1 4.4
5.65
5 5 8 10
25.4
4.7
25.4
29
4.7
9 12
31
9
13 14 13 14
11.85
0.3
21.2 3 (Bottom View)
0.3
18
12.5
3 (Bottom View)
11
5.95
11
31 min.*
6.6
2-2 holes
29 min.*
15 8-2.4 holes
15
Signaling Lights
2
1.5 (Tolerance 0.1) 2
* 36 min. when using * 34 min. when using (Tolerance 0.1)
12.2 hold-down springs hold-down springs
SH3B-62 SH4B-62
Terminal Arrangement 36 min. Terminal Arrangement 6.85 45 min.
7.35 21.3 1 2 3 4 31.3
1 2 4
6.65
5 6 8 10 10 5 6 7 8 10 10 10
25.4
4.7
31
25.4
4.7
9 10 11 12
31
9 10 12
13 14
13 14
0.3
45 3 (Bottom View)
0.3
Relays & Sockets
36 3 (Bottom View)
6.65
12.5
12.5
11
11
15
6.6
6.6
31 min.*
31 min.*
15 14-2.4 holes
11-2.4 holes
2
2 39.2 * 36 min. when using
hold-down springs (Tolerance 0.1)
30.2 * 36 min. when using (Tolerance 0.1)
hold-down springs
Timers
Contactors
Terminal Blocks
Circuit Breakers
782 www.IDEC.com
Relays & Sockets RR
Signaling Lights
Part Number Selection
Part Number
Coil Voltage Code
Contact Model Pin Terminal Blade Terminal*
(Standard Stock Items in Bold)
SPDT Standard RR1BA-U 0
Timers
Side Flange Model RR2BA-US 0
Contactors
*Blade type not TUV tested or CE marked.
Side flange model mounts directly to panel with no socket required. Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RR3B-U AC120V
Part No. Coil Voltage Code
Sockets
Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount Through Panel Mount
Terminal Blocks
SR2P-05
RR2P SR2P-05C SR2P-51
SR2P-06
SR3P-05
RR3PA SR3P-05C SR3P-51
SR3P-06
RR1BA
RR2BA SR3B-05 SR3B-51
RR3B
Circuit Breakers
Leaf Spring
RR2P, RR3PA SFA-203
(side latch)
Signaling Lights
Accessories
Item Appearance Use with Part No. Remarks
The BNDN1000 is designed to accommodate DIN mount sockets.
Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).
Relays & Sockets
784 www.IDEC.com
Relays & Sockets RR
Specifications
Signaling Lights
Between live and dead parts: 1500V AC, 1 minute
Between contact and coil: 1500V AC, 1 minute
Pin Terminal
Between contacts of different poles: 1500V AC, 1 minute
Dielectric Between contacts of the same pole: 1000V AC, 1 minute
Strength Between live and dead parts: 2000V AC, 1 minute 1. Measured using 5V DC, 1A voltage drop method
2. Measured at the rated voltage (at 20C), excluding contact
Between contact and coil: 2000V AC, 1 minute bouncing
Blade Terminal 3. For use under different temperature conditions, refer to
Between contacts of different poles: 2000V AC, 1 minute
Continuous Load Current vs. Operating Temperature Curve.
Timers
Operating Temperature 3
25 to +40C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)
Weight (approx.) (Standard type) RR2P: 90g, RR3PA: 96g, RR1BA/RR2BA/RR3B: 82g
Coil Ratings
Rated Current (mA) 15% (at 20C) Operating Characteristics (values at 20C)
Coil Resistance ()
Rated Voltage (V) Maximum Continuous
50 Hz 60 Hz 10% (at 20C) Pickup Voltage Dropout Voltage
Contactors
Applied Voltage
6 490 420 4.9
12 245 210 18
AC 24 121 105 79
110% 80% maximum 30% minimum
(50/60 Hz) 110 27 23 1,680
120 24 20.5 2,100
240 12.1 10.5 8,330
Terminal Blocks
6 240 25
12 120 100
DC 24 60 400 110% 80% maximum 10% minimum
48 30 1,600
110 13 8,460
Circuit Breakers
Maximum Contact Capacity Voltage Resistive General use Horse Power Rating
Allowable Contact Power Rated Load 240V AC 10A 7A 1/3 HP
Continuous
Current Resistive Inductive 120V AC 10A 7.5A 1/4 HP
Voltage (V) Res. Load Ind. Load
Load Load 30V DC 10A 7A
110 AC 10A 7.5A
1650VA AC 1100VA AC CSA Ratings
10A 220 AC 7.5A 5A
300W DC 150W DC
30 DC 10A 5A Voltage Resistive General use
240V AC 10A 7A
Note: Inductive load for the rated load cos = 0.3, L/R = 7 ms
Signaling Lights
Socket Specifications
Relays Terminal Electrical Rating Wire Size Torque
SR2P-05 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
SR2P-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
SR2P-06 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
DIN Rail
SR3P-05 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
Sockets
SR3P-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
SR3P-06 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
Timers
SR3B-05 M3 screw with captive wire clamp 300V, 15A (10A)* (*CSA rating) Maximum 2 - #12 AWG 9 - 11.5inlbs
SR2P-51 Solder 300V, 10A
Through
Panel Mount SR3P-51 Solder 300V, 10A
Sockets
SR3B-51 Solder 300V, 10A
Contactors
Terminal Blocks
Circuit Breakers
786 www.IDEC.com
Relays & Sockets RR
500 500
30V DC
100 100
110V AC resistive
100V DC resistive
50 50
Signaling Lights
220V AC resistive
110V AC inductive 100V DC inductive
20 20
220V AC inductive
30V DC inductive
10 10
0.1 0.5 1 5 10 0.01 0.05 0.1 0.5 1 5 10
Load Current (A) Load Current (A)
DC Coil
60
1.0
DC inductive 50
AC Coil
0.5 40
30
20
10
1 5 10 30 50 100 200 300 0
1 2 3 4 5 6 7 8 9 10
Load Voltage (V) Load Current (A)
Timers
Internal Connection (View from Bottom)
Standard Type
RR2P-U RR3PA-U RR1BA-U RR2BA-U RR3B-U With Check Button
Front
Pushbutton
Contactors
check button.
Terminal Blocks
Coil
Below
100V When the relay is energized,
AC/DC the indicator goes on.
An LED protection diode is
not contained in relay coils
below 100V DC.
Coils below 100V use
LED indicator while coils
above 100V use neon lamp
Coil
Circuit Breakers
indicator.
100V
AC/DC
and over
Dimensions (mm)
Switches & Pilot Lights
RR2P-U/RR2P-UL RR3PA-U/RR3PA-UL
Total length from panel surface including relay socket Total length from panel surface including relay socket
SR2P-05: 84.5 (87.5) max., SR2P-511: 63 (68) max. SR3P-05: 84.5 (87.5) max., SR3P-511: 63 (68) max.
6
5 7
4 5 4 8
3 6
35.6
35.6
2 7 3 9
1 8
2 10
1 11
9.9 9.9
28.6 35.6
Signaling Lights
RR1BA-U/RR2BA-UL/RR2BA-U
RR2BA-UL/RR3B-U/RR3B-UL RR1BA-US/RR2BA-US/RR3B-US
63.5
11.1
Relays & Sockets
16.0
4.2
11.1
3.0 2.0 oblong hole
63.5
4.7
47.5 max. 16.1
73.5
0.5
1 2 3
4 5 6
7 8 9
36
0.5
1 2 3
4 5 6
A B
7 8 9
36
36 A B
47.5 max. 7.3
Dimensions in the ( ) 36
include a hold-down spring.
Timers
25
52
33
25
60
29 7 2
33
8 1
4.4 max. 5 min.
4.2 hole (Top View) 4.9 max. 5 min. 7 8 1 2
16.5 4.2 hole
33 (Top View)
18
3
29 20
7.9 max.
28.5 22 7.9 max.
1
3.6 min.
3.6 min.
SR3P-05 SR3P-06
42 59
Terminal Blocks
33
27
60
34 9 3 33
10 11 1 2
4.4 max. 5 min. 4.2 hole
4.2 hole (Top View) 4.9 max. 5 min.
9 10 11 1 2 3
34 16.5
18 (Top View)
20 33
7.9 max.
3
3.6 min.
3.6 min.
Circuit Breakers
788 www.IDEC.com
Relays & Sockets RR
37
76
56
B A
4.4 max. 5.5 min. 9 8 7
(Top View)
Signaling Lights
7.9 max.
37 14.5 3.6 min.
43 25
2
29
58
4.2 hole
58
7 2
4.2 hole 34 9 3
8 1
10 11 1 2
(Top View)
Ring type crimping (Top View)
21.5 terminals cannot be used.
29
2.2
Timers
Surfarface
Surfarface
2-3.5 Mounting Holes 2-3.5 Mounting Holes
4.2 4.2 (or M3 Tapped Holes)
(or M3 Tapped Holes)
Panel
Panel
Terminal Arrangement
6
6
Terminal Arrangement
4 5 5 6 7
3 6 4 8
0
0
29
29
38
38
50
38
38
50
3
3
3 9
2 7
2 10
1 8 1 11
Contactors
SR3B-51
35.5* 2-4.2 Mounting Holes
38 7.5 11 max. Terminal Arrangement (M4 Tapped Holes)
6.75 22
11.5 min.
1 2 3
0.3
4 5 6
32.5
51.5
32
35
43
43
7 8 9
A B
22 3 6.5
(Bottom View)
(Tolerance 0.3)
Terminal Blocks
3.5 *When two or more sockets are
35 mounted side by side:
L = 38 (N 1) + 35.5
N: No. of sockets mounted Circuit Breakers
Key features:
Full featured universal miniature relays
Designed with environment taken into consideration
Two terminal styles: plug-in and PCB mount
Non-polarized LED indicator
No internal wires, lead-free construction
Cadmium-free contacts
Mechanical flag indicator
Signaling Lights
EN61810-1
Relays & Sockets
With Latching or Momentary Lever
Latching and Momentary Lever
Using the lever, operation can be checked without energiz-
Mechanical Indicator*
ing the coil. The lever is color coded for AC and DC coils.
The contact position can be confirmed through
the five small windows. Latching Momentary
AC coil: Orange Red
Marking Plate
Standard yellow marking plate is easily replaced DC coil: Green Blue
with optional marking plates in four colors for
easy identification of relays.
Timers
In Normal Operation
LED Indicator*
Non-polarized green LED indicator is standard
provision for plug-in terminal, latching lever
types
Note: Turn off the power to the relay coil when using the latching
Contactors
6V DC
AC Coil DC Coil
12V DC Voltage marking on
48V DC yellow tape
*Not available on PCB type.
110V DC
790 www.IDEC.com
Relays & Sockets RU
Signaling Lights
A24, A110, A220
PCB RU2V-NF-0
D6, D12, D24, D48, D110
4PDT (6A) A24, A110, A220
Standard RU4S-C-0 RU4S-0 RU4S-M-0
D6, D12, D24, D48, D110
With RC (AC coil only) RU4S-CR-0 RU4S-R-0 RU4S-MR-0 A110, A220
With diode (DC coil only) RU4S-CD-0 RU4S-D-0 RU4S-MD-0 D6, D12, D24, D48, D110
A24, A110, A220
PCB RU4V-NF-0
D6, D12, D24, D48, D110
1. Plug-in terminal models have an LED indicator and a mechanical indicator as standard.
2. PCB models do not have an LED indicator or a mechanical indicator. Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RU2S-C A110
Timers
Part No. Coil Voltage Code
Sockets
Spring Clamp Standard DIN Finger-safe DIN
Contactors
Relays Panel Mount PCB Mount
DIN Rail Mount Rail Mount Rail Mount
SM2S-61
RU2S (DPDT) SU2S-11L SM2S-05 SM2S-05C
SM2S-62
SY4S-51
RU4S (4PDT) SY4S-61
SU4S-11L SY4S-05 SY4S-05C
RU42S (4PDT) SY4S-62
Terminal Blocks
Circuit Breakers
For Through
For DIN
Appearance Item Relay Panel & PCB
Mount Socket
Mount Socket
Accessories
Name Part Number Color Code *
Relays & Sockets
Specify a color code when ordering. The marking plate can be removed from the relay by inserting
a flat screwdriver under the marking plate.
Specifications
Model (Contact) RU2 (DPDT) RU4 (4PDT) RU42 (4PDT-bifurcated)
Contact Material Silver alloy Silver (gold clad) Silver-nickel (gold clad)
Contact Resistance 1
50 m maximum
Timers
Shock Resistance
Operating extremes: 150 m/s2 (15G)
AC: 50,000,000 operations
Mechanical Life 50,000,000 operations
DC: 100,000,000 operations
Electrical Life 4 See table on page 794
Operating PCB model: 55 to +70C (no freezing)
Temperature 5 Blade model: 55 to +60C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)
Weight Approx. 35g
Circuit Breakers
1. Measured using 5V DC, 1A voltage drop method 4. Contact Load and Electrical Life (at ambient temperature 20C)
2. Measured at operating frequency of 120 operations/min (failure rate level P, reference value) 5. Measured at the rated voltage.
3. Measured at the rated voltage (at 20C), excluding contact bouncing;
Release time of AC relays with RC: 25 ms maximum
Release time of DC relays with diode: 40 ms maximum
792 www.IDEC.com
Relays & Sockets RU
Accessories
Signaling Lights
Replacement
Horseshoe clip for DIN rail For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
sockets spring. 2 pieces included with each socket.
Spring Anchor
Coil Ratings
Rated Current (mA)
Coil Operating Characteristics (values at 20C)
15% (at 20C) Coil Resistance ()
Rated Voltage (V) Voltage
10% (at 20C) Maximum Continuous
Code
Timers
1. The rated current includes the current of the LED indicator.
Contactors
R: 20 k, C: 0.033 F
250V AC 10A 3A 6A 1/10HP
Diode reverse voltage: 1000V
DC Coil With Diode 30V DC 10A 6A 3A
Diode forward current: 1A
Terminal Blocks
Contact
Current Resistive Load Inductive Load (V) Res. Load Ind. Load 30V DC 3A 30V DC 10A 6A 3A 5A 1.5A 1.5A
2500VA AC 1250VA AC 250 AC 10A 5A
DPDT 10A
300W DC 150W DC 30 DC 10A 5A
1500VA AC 600VA AC 250 AC 6A 0.8A
4PDT 6A
180W DC 90W DC 30 DC 6A 1.5A
4PDT 750VA AC 200VA AC 250 AC 3A 0.8A
3A
bifurcated 90W DC 45W DC 30 DC 3A 1.5A
Circuit Breakers
1. On 4PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated
load, make sure that the total current of neighboring two poles does not exceed 6A (3A + 3A = 6A).
2. Inductive load for the rated load cos = 0.3, L/R = 7 ms
Socket Specifications
Switches & Pilot Lights
( 10,000 operations)
100
( 10,000 operations)
( 10,000 operations)
100 100
10 10 10
1 1 1
0.1 0.5 1 5 10 0.1 0.5 1 3 6 0.02 0.1 0.5 1 3 6
Timers
( 10,000 operations)
( 10,000 operations)
100
100 100
Contactors
10 10 10
AC: cos = 0.3
DC: L/R = 7 ms AC: cos = 0.3 AC: cos = 0.3
DC: L/R = 7 ms DC: L/R = 7 ms
1 1 1
0.1 0.5 1 5 10 0.02 0.1 0.5 0.02 0.1 0.5
Load Current (A) Load Current (A) Load Current (A)
DC resistive
Load Current (A)
1
Circuit Breakers
DC inductive
0.1 L/R = 7 ms
794 www.IDEC.com
Relays & Sockets RU
Load current
Signaling Lights
40 Load current 40 40
5A 2 poles
30 30 Load current 30 Load current
No load current 5A 2 poles 5A 2 poles
20 20 20 No load current
No load current
10 10 10
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)
RU4/RU42 (AC Coil, 50 Hz) RU4/RU42 (AC Coil, 60 Hz) RU4/RU42 (DC Coil)
120 120 120
80 80 80
Load current
70 6A 2 poles 70 70
Load current Load current
60 60 6A 2 poles 60 6A 2 poles
50 50 50
40 Load current 40 40
3A 4 poles
30 30 Load current 30 Load current
No load current 3A 4 poles 3A 4 poles
20 20 20 No load current
No load current
10 10 10
Timers
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)
The above temperature rise curves show the characteristics when 100% the rated coil voltage is applied.
The heat resistance of the coil is 120C. The slant dashed line indicates the allowable temperature rise for the coil at different ambient temperatures.
Load current 6A x 2 poles is for the RU4 models only.
Contactors
Terminal Blocks
Circuit Breakers
(5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44
(9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41
35.0
0.5
13.2
0.5 0.8
4.0
14
4
21.0
21.0
Terminal Blocks
13
1
27.5
27.5
Mounting Hole Layout
7.0 oles
Marking plate removal slot is provided only on one side. 1H
8-
Insert a flat screwdriver into the slot to remove the marking
plate.
13.2
6.4
4.1 12.7
796 www.IDEC.com
Mechanical Indicator Window
Marking Plate (yellow) Relays & Sockets Marking Plate (yellow) RU
Color Marking
Latching LED Indicator
Dimensions contAC: Yellow
(mm)
35.0
35.0
0.5
3-4.4
0.5
2.6
4.0
0.5 0.8
Signaling Lights
6.4
2.6
1.2 2.2 Hole
12
14
4
8
21.0
11
3
21.0
10
2
13
1
27.5 27.5
Marking plate removal slot is provided only on one side. Mounting Hole Layout es
Insert a flat screwdriver into the slot to remove the marking 7.0 Hol
1
plate. 14-
Timers
Terminal Arrangement Terminal Arrangement
12 9 12 11 10 9
8 5 8 7 6 5
2-3.2 2-3.2
24.0 Mounting Holes 4 1 24.0 Mounting Holes 4 3 2 1
80
80
37.5
37.5
28.8
28.8
14 13 14 13
Contactors
38.3 cannot be used. 38.3 cannot be used.
6
DIN Rail
0.7
6 18
DIN Rail M3 Terminal 18 (BNDN)
M3 Terminal Terminal Arrangement
(BNDN) Terminal Arrangement Screw 2-4.2 Mounting Holes
Screw 8 7 6 5
(or M4 Tapped Holes)
Terminal Blocks
2-4.2 Mounting Holes 8 5
4 3 2 1
(or M4 Tapped Holes) 4 1
26
62
45
62
45
26
4 max. 4.8 min. 14 13
4.2
14 13
4 max. 4.8 min.
4.2
12 11 10 9
12 9
3.2 min.
3
3.2 min.
Circuit Breakers
4.2
4.2
46
64
26 26
64
46
14 13
Signaling Lights
14 13 12 11 10 9
Ring terminals
12 9 Ring terminals (Top View)
cannot be used. (Top View) cannot be used.
26 18.2
26 18.2
1.6
1.6
29
2
2
29
4.1
1 4
4.1
10.4
5 8 1 4
25.4
10.4
31
5 8
9
9 12
16.8
0.3
29
9 12
9
13 14
16.8
13 14
0.3
27 3 (Bottom View)
1.4
21.2 3 (Bottom View)
9-2 holes
14.2 min.*
11 11
9-2 holes
12.2 min.*
15 15
1.4
(Tolerance 0.1)
* 19.2 min. when using (Tolerance 0.1)
1.5
hold-down springs 1.5 * 17.2 min. when using a hold-down spring.
21.2
** 13.2 min. when using a hold-down spring for
the relay with check button.
SY4S-61 SY4S-62
Timers
4.1
4.1
1 2 3 4
1 2 3 4
10.4
5 6 7 8
9
16.8
5 6 7 8
0.3
29
25.4
9 10 11 12
9
31
16.8
9 10 11 12 13 14
13 14
1.4
21.2 3 (Bottom View)
0.3
27 3 (Bottom View)
14.2 min.*
11 15-2 holes
12.2 min.*
11 15
15-2 holes
15 (Tolerance 0.1)
1.4
* 19.2 min. when using (Tolerance 0.1) 1.5 * 17.2 min. when using a hold-down spring.
1.5
hold-down springs
* *13.2 min. when using a hold-down spring for
Contactors
21.2
the relay with check button
+0.2
5 6 7 8
0
25.4
31
9 10 11 12
25.6
13 14
0.3
11
18.7
798 www.IDEC.com
Relays & Sockets RY/RM
Signaling Lights
Part Number Selection
Part Number
Contact Model Plug-in Terminal PC Board Terminal Coil Voltage Code
Standard RY2S-U 0 RY2V-U 0
DPDT (Slim) 3A
With Indicator RY2S-UL 0 RY2V-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
Timers
Top Bracket Mounting RM2S-UT 0
With Diode (DC coil only) RM2S-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RM2S-ULD 0
Standard RY4S-U 0 RY4V-U 0
Contactors
RY4S-ULC 0
Top Bracket Mounting RY4S-UT 0
With Diode (DC coil only) RY4S-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RY4S-ULD 0
Top mount models are designed to mount directly to a panel and do not require a socket.
Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RY4S-U AC110-120V
Part No. Coil Voltage Code Terminal Blocks
Circuit Breakers
Sockets
Switches & Pilot Lights
RY2S
Leaf Spring 1
SFA-202 2 SFA-302
(side latch)
RM2, RY4S
RY2S
Leaf Spring 1
RM2 SFA-101 2 SFA-301
Timers
(top latch)
RY4S
1. Not available for PCB mount socket SY4S-62.
2. Order 2 pieces per relay.
Accessories
Item Appearance Use with Part No. Remarks
Contactors
Replacement
Horseshoe clip for all DIN rail For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
Terminal Blocks
800 www.IDEC.com
Relays & Sockets RY/RM
Specifications
Signaling Lights
Power Consumption AC: 1.1 VA (50 Hz), 1 VA (60 Hz) AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)
(approx.) DC: 0.8W DC: 0.9W DC: 0.9W
Insulation Resistance 100 M minimum (500V DC megger)
Between live and dead parts:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Between contact and coil:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Dielectric Strength
Timers
Mechanical Life 50,000,000 operations
100,000 operations (220V AC, 5A)
Electrical Life 200,000 operations (220V AC, 3A) 500,000 operations (220V AC, 5A)
200,000 operations (220V AC, 3A)
Operating Temperature 3 25 to +55C (no freezing) 25 to +45C (no freezing) 25 to +55C (no freezing) 4
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) 23g 35g 34g
Note: Above values are initial values. 3. For use under different temperature conditions, refer to Continuous Load
Contactors
1. Measured using 5V DC, 1A voltage drop method Current vs. Operating Temperature Curve. The operating temperature range
2. Measured at the rated voltage (at 20C), excluding contact bouncing of relays with indicator or diode is 25 to +40C.
Release time of relays with diode: 40 ms maximum 4. When the total current of 4 contacts isless than 15A, the operating tem-
perature range is 25 to +70C.
Terminal Blocks
Circuit Breakers
AC Coil Ratings
Switches & Pilot Lights
Rated Current (mA) 15% at 20C Coil Resistance () 10% Operation Characteristics
AC 50Hz AC 60Hz at 20C (against rated values at 20C)
Voltage (V)
DPDT DPDT Wide & DPDT DPDT Wide & DPDT DPDT Wide & Max. Continuous Pickup Dropout
Slim 4PDT Slim 4PDT Slim 4PDT Applied Voltage Voltage Voltage
6 170 240 150 200 18.8 9.4
12 86 121 75 100 76.8 39.3
24 42 60.5 37 50 300 153
110 9.6 8.4 6,950
Signaling Lights
30%
110-120 9.4-10.8 8.0-9.2 4,290 110% 80% maximum
minimum
120 8.6 7.5 8,100
220 4.7 4.1 25,892
220-240 4.7-5.4 4.0-4.6 18,820
240 4.9 4.3 26,710
DC Coil Ratings
Relays & Sockets
3A 220V AC 3A 0.8A
(RY2) 90W DC 45W DC
100V DC 0.2A 0.4A 0.2A 0.2A 0.2A
30V DC 3A 1.5A
30V DC 3A 5A 5A 3A 5A
110V AC 5A 2.5A
DPDT Wide 1100VA AC 440VA AC
5A 220V AC 5A 2A
(RM2) 150W DC 75W DC CSA Ratings
30V DC 5A 2.5A
Resistive General use
1200 VA AC 288 VA AC 240V AC 5A 1.2A Voltage
4PDT (RY4) 5A DPDT DPDT DPDT DPDT
150W DC 60W DC 30V DC 5A 2A 4PDT 4PDT
Slim Wide Slim Wide
Terminal Blocks
Note: Inductive load for the rated load cos = 0.3, L/R = 7 ms 240V AC 3A 5A 5A 0.8A 2A 5A
120V AC 3A 5A 1.5A 2.5A
TV Ratings 100V DC 0.2A 0.4A 0.2A
DPDT DPDT 30V DC 3A 5A 5A 1.5A 2.5A 1.5A
Voltage 4PDT
Slim Wide
240V AC 3A 5A 5A
30V DC 3A 5A 5A
AC: cos = 1.0, DC: L/R = 0 ms
Circuit Breakers
802 www.IDEC.com
Relays & Sockets RY/RM
Socket Specifications
Signaling Lights
Through
Panel Mount SM2S-51 Solder 250V, 10A
Socket
SY4S-51 Solder 250V, 7A*
SY2S-61 PCB Mount 300V, 7A
PCB Mount
SY4S-61 PCB Mount 300V, 7A
Socket
SY4S-62 PCB Mount 250V, 7A
* When using only 2 poles of the 4-poles, the UL recognized current is 10A.
1000 1000
240V AC resistive
200
200
100
100
Signaling Lights
240V AC inductive
50
50
20 20
110V AC inductive
10 220V AC inductive 10
0 1 2 3 0 1 2 3 4 5
Load Current (A) Load Current (A)
1000
Life ( 10,000 operations)
500
100
50
110V AC inductive
220V AC inductive
10
0 1 2 3 4 5
Load Current (A)
Timers
DC Load `
(RY2) 30V DC resistive (RY4)
1000 30V DC inductive 1000
500 500
Life ( 10,000 operations)
Life ( 10,000 operations)
200
200 30V DC resistive
100
Contactors
20 20
100V DC resistive
100V DC inductive 10
10
0 5 2 3 0 1 2 3 4 5
Load Current (A) Load Current (A)
(RM2)
30V DC resistive
Terminal Blocks
500
100
50
100V DC resistive
100V DC inductive
Circuit Breakers
10
0 1 2 3 4 5
Load Current (A)
804 www.IDEC.com
Relays & Sockets RY/RM
3 3
AC resistive
2
AC
inductive DC resistive
1 1
DC inductive DC resistive
0.5 0.5
DC inductive
0.3
Signaling Lights
0.2
0.1
1 5 10 50 100 200 300 1 10 20 30 50 100 200 300
Load Voltage (V) Load Voltage (V)
(RM2)
5
AC resistive
AC
Load Current (A)
inductive
1 DC inductive DC
resistive
0.1
1 5 10 50 100 200 300
Load Voltage (V)
Continuous Load Current vs. Operating Temperature Curve (Standard Type, With Check Button, and Top Bracket Mounting Type)
(RM2) 100
(RY2) 100 (RY4) 100
90
Timers
90 90
80
70 DC Coil
70
60
60 60
AC Coil 50
50 50 AC Coil AC Coil
40 40 40
30 30 30
20 20 20
10 10 10
Contactors
0 0 0
1 2 3 1 2 3 1 2 3 4 5
Load Current (A) Load Current (A) Load Current (A)
Terminal Blocks
Circuit Breakers
Standard Type
DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4) With Check Button
Front
Pushbutton
Coil Coil
Below Below
100V 24V AC/ When the relay is energized,
AC/DC DC the indicator goes on.
An LED protection diode
is not contained in DPDT
Relays & Sockets
1 4 1 2 3 4
5 8
Coil Coil 24V 9 12
5 6 7 8
Contains an LED
9 10 11 12
Below DC and indicator and a surge
24V DC over 13() (+)14 absorber.
13() (+)14
Terminal Blocks
Circuit Breakers
806 www.IDEC.com
Relays & Sockets RY/RM
Dimensions (mm)
2.6
2.6 2.2 1.2 hole
2.6
1 4
5 8
1 4
27.5
9 12
5 8
0.5
Signaling Lights
1 2 3 4 13 14
27.5
0.5
9 12
5 6 7 8
13 14
27.5
0.5
9 10 11 12
35.6 max. 6.4 21
13 14
0.8
8-1 holes
4.1
0.8
2.6
2.6
1 4
8-1 hole
7.15
5 8
4.1
27.5
12.7
9 12
4.1
0.5
1 2 3 4
7.15
6.4
13 14 5 6 7 8
1 4
27.5
0.5
12.7
9 10 11 12
5 8
6.4
13 14
27.5
9 12
12.7
35.6 max. 4 14 4.4
0.5
13 14
6.4
13.2
7.15
4.4 35.6 max. 4 21
Timers
RY2S-UT RY4S-UT RM2S-UT
2.6
4.4
13.2
4.4
4.4
2.6
2.2 1.2 hole
4.4
4.1
0.5
0.5
4.1
Contactors
1 4
1 4
5 8 1 2 3 4
5 8
6.3
5 6 7 8
43.2
27.5
6.3
9 12
38
43.2
27.5
6.3
9 12
38
43.2
27.5
9 10 11 12
38
13 14
13 14
13 14
6.4
6.4
6.4
Terminal Blocks
Circuit Breakers
Dimensions
Switches & Pilot Lights
0.7
6 6 18
18 DIN Rail DIN Rail
M3 Terminal M3 Terminal
(BNDN) Terminal Arrangement (BNDN) Terminal Arrangement
Screw Screw
2-4.2 Mounting Holes 8 5
8 5 2-4.2 Mounting Holes
(or M4 Tapped Holes) (or M4 Tapped Holes) 4 1
4 1
62
45
62
45
16 26
14 13
4 max. 4.8 min.
4.2
4 max. 4.8 min. 14 13
Signaling Lights
4.2
12 9
12 9
3
20 25
2
3.2 min.
3.2 min.
SY4S-05
30
31.5
0.7
6
DIN Rail
M3 Terminal 18 (BNDN) Terminal Arrangement
Screw 2-4.2 Mounting Holes
8 7 6 5
(or M4 Tapped Holes)
4 3 2 1
Relays & Sockets
26
62
45
12 11 10 9
3.2 min.
6 DIN Rail 6
Screw 25 Terminal Arrangement M3 Terminal 25 (BNDN)
(BNDN) 2-4.2 Mounting Holes Terminal Arrangement
Screw
8 5 2-4.2 Mounting Holes
(or M4 Tapped Holes)
5 4 1 5.5 18 (or M4 Tapped Holes) 8 5
4 1
4.2
4.2
16
26
64
46
64
46
14 13
12 9 14 13
Ring terminals (Top View) 12 9
Ring terminals
cannot be used. (Top View)
16 18.2 cannot be used.
26 18.2
1.6
20 29
1.6
2
29
Contactors
SY4S-05C
30 35.5
6 M3 Terminal DIN Rail
25
Screw (BNDN) Terminal Arrangement
2-4.2 Mounting Holes 8 7 6 5
5.5 18
(or M4 Tapped Holes) 4 3 2 1
4.2
46
64
26
14 13
12 11 10 9
Ring terminals
Terminal Blocks
(Top View)
cannot be used.
26 18.2
1.6
29
2
Circuit Breakers
808 www.IDEC.com
Relays & Sockets RY/RM
+0.2
0
1 4
+0.2
5 8
25.4
25.6
31
5 8 9 12
25.4
31
25.6
9 12 13 14
13 14
0.3
27 3 (Bottom View) N: No. of sockets mounted
0.3
5.4 min.*
18 3 (Bottom View) N: No. of sockets mounted 11
5.4 min.*
11 18.7
18.7 2.4 * 10.4 min. when using hold-down springs
21.2
2.4 * 10.4 min. when husing hold-down springs
Signaling Lights
12.2
SY4S-51
Panel Thickness: [27 (N1) + 21.4] + 0.5
0
1 to 2
Terminal Arrangement
1 2 3 4
+0.2
5 6 7 8
0
25.4
31
9 10 11 12
25.6
13 14
0.3
11
4.4
1 4 Terminal Arrangement
10.4
Timers
4.1
5 8
9
25.4
1 2 3 4
31
16.8
9 12
25.4 5 6 7 8
9
13 14
31
16.8
9 10 11 12
14.2 min.*
13
0.3
(Bottom View) 14
18 3
0.3
27 3 (Bottom View)
14.2 min.*
11 8-2 holes
11
15 15-2 holes
* 19.2 min. when using (Tolerance 0.1) 15
1.4
1.5 hold-down springs
* 19.2 min. when using (Tolerance 0.1)
1.5
12.2 hold-down springs
21.2
SY4S-62
Contactors
13.2 8.2 min.**
8.8
4.4
Terminal Arrangement
4.1
1 2 3 4
10.4
5 6 7 8
9
16.8
0.3
29
9 10 11 12
13 14
1.4
15
Terminal Blocks
(Tolerance 0.1)
Key features:
Compact and EN compliant RF1V force guided relays
Force guided contact mechanism
(EN50205 Type A TV approved)
Contact configuration
4-pole (2NO-2NC, 3NO-1NC)
6-pole (4NO-2NC, 5NO-1NC, 3NO-3NC)
Built-in LED indicator available.
Signaling Lights
Certification Organization/
Applicable Standard Marking
File Number
UL508
UL/c-UL File No. E55996
CSA C22.2 No.14
Relays & Sockets
EN50205
TV SD
EN61810-1
4 SF1V-4-61 EN147100
PC Board EC Low Voltage Directive
Mount Sockets (DIN rail mount sockets only)
6 SF1V-6-61
810 www.IDEC.com
Relays & Sockets RF1V
Coil Ratings
Signaling Lights
3NO-1NC 24V DC 15 1600
48V DC 7.5 6400
12V DC 41.7 288
4NO-2NC 24V DC 20.8 1152 75% maximum 10% minimum 110%
48V DC 10.4 4608
12V DC 41.7 288
6-pole 5NO-1NC 24V DC 20.8 1152 Approx. 0.5W
Accessories
Item Appearance Specifications Type No. Remarks
Timers
Aluminum Length: 1m
DIN Rail BNDN1000
Weight: Approx. 250g Width: 35 mm
BNL5
Metal (zinc plated steel)
End Clip
Weight: Approx. 15g
BNL6
Contactors
Terminal Blocks
Circuit Breakers
Specifications
Switches & Pilot Lights
Dielectric
Between contacts of different poles 4000V AC, 1 min.
Strength 4000V AC, 1 min.
Between contacts 3-4 and 5-6
Between contacts 3-4 and 5-6
Between contacts 3-4 and 7-8
Between contacts 3-4 and 7-8
Between contacts 5-6 and 9-10
Between contacts 5-6 and 9-10
Between contacts 7-8 and 9-10
Between contacts of the same pole 1500V AC, 1 minute
Operating Time (at 20C) 20 ms maximum (at the rated coil voltage, excluding contact bounce time)
Response Time (at 20C) 3 8 ms maximum (at the rated coil voltage, excluding contact bounce time)
Release Time (at 20C) 20 ms maximum (at the rated coil voltage, excluding contact bounce time)
Operating Extremes 10 to 55 Hz, amplitude 0.75 mm
Timers
Vibration
Resistance Damage Limits 10 to 55 Hz, amplitude 0.75 mm
Shock Operating Extremes (half sine-wave pulse: 11 ms) 200 m/s2, when mounted on DIN rail mount socket: 150 m/s2
Resistance Damage Limits (half sine-wave pulse: 6 ms) 1000 m/s2
250V AC 6A resistive load: 100,000 operations minimum (operating frequency 1200 per hour)
30V DC 6A resistive load: 100,000 operations minimum (operating frequency 1200 per hour)
250V AC 1A resistive load: 500,000 operations minimum (operating frequency 1800 per hour)
Electrical Life
30V DC 1A resistive load: 500,000 operations minimum (operating frequency 1800 per hour)
[AC 15] 240V AC 2A inductive load: 100,000 operations minimum (operating frequency 1200 per hour, cos = 0.3)
Contactors
[DC 13] 24V DC 1A inductive load: 100,000 operations minimum (operating frequency 1200 per hour, L/R = 48 ms)
Mechanical Life 10 million operations minimum (operating frequency 10,800 operations per hour)
Operating Temperature 4
40 to +85C (no freezing)
Operating Humidity 5 to 85%RH (no condensation)
Storage Temperature 40 to +85C
Operating Frequency (rated load) 1200 operations per hour
Weight (approx.) 20g 23g
Terminal Blocks
1. Measured using 6V DC,1A voltage drop method. 3. Response time is the time until NO contact opens, after the coil voltage is turned off.
2. Failure rate level P (reference value) 4. When using at 70 to 85C, reduce the switching current by 0.1A/C.
Circuit Breakers
812 www.IDEC.com
Relays & Sockets RF1V
6.3 max.
3.0 min.
Rated Current 6A
Rated Voltage 250V AC/DC
1000 M minimum
Insulation Resistance
(500V DC megger, between terminals)
Dielectric Strength 2500V AC, 1 minute (between terminals) 4.0 max. 6.5 min.
Signaling Lights
Recommended Screw
0.5 to 0.8 Nm
Tightening Torque
Terminal Strength Wire tensile strength: 50N min.
Damage limits: 10 to 55 Hz, amplitude 0.75 mm
Vibration Resistance
Resonance: 10 to 55 Hz, amplitude 0.75 mm
Shock Resistance 1000 m/s2
Operating Temperature 1
40 to +85C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)
Characteristics
Maximum Switching Capacity Electrical Life Curve Notes on Contact Gaps except Welded Contacts
500
Timers
1 3 4 7 8
+
Example: RF1V-2A2B-D24
Life (10,000 operations)
6 2 5 6 9 10
Contactors
0.1 1
1 10 100 250 0.1 1 10 If the NC contact (3-4 or 5-6) welds, the NO contact (7-8 or 9-10)
Load Voltage (V) Load Current (A)
remains open even when the relay coil is energized, maintaining a
gap of 0.5 mm. The remaining unwelded NC contact (5-6 or 3-4) is
either open or closed.
Terminal Blocks
Circuit Breakers
5.08 0.1
10.16 0.1
(1.83)
13.970.1 11.43 0.1
24 max.
Signaling Lights
24 max.
5.08
RF1V (6-pole)
1.0 1.83 0.5
1.0 1.83
3.5
0.5 le
3.5
10.16 13.97 5.08
10.16 13.97 5.08 ho
1.4
5.08 11.43
5.08 1 4-
5.08 5.08
11.43
10.16 0.1
13.97 0.1 5.08 0.1
5.08 0.1 5.08 0.1
Relays & Sockets
11.43 0.1
22 55 66
4NO-2NC
4NO-2NC 99 10
10 13
Contact
Contact13 14
14 22 55 66
5NO-1NC
5NO-1NC 99 10
10 13
Contact
Contact13 14
14 22 55 66
3NO-3NC
3NO-3NC 99 10
10 13
Contact
Contact13 14
14
25 2NO-2NC
2 2NO-2NC 6 Contact Contact
5 96 10 9 10 2 3NO-1NC
253NO-1NC
6 Contact Contact
5 96 10 9 10
2NO-2NC
2NO-2NC
ContactContact 3NO-1NC
3NO-1NC
ContactContact 4NO-2NC
4NO-2NC Contact
Contact 5NO-1NC
5NO-1NC Contact
Contact 3NO-3NC
3NO-3NC Contact
Contact
2NO-2NC
2NO-2NC
ContactContact 3NO1NC
3NO1NC
ContactContact 4NO-2NC
4NO-2NC Contact
Contact 5NO-1NC
5NO-1NC Contact
Contact 3NO-3NC
3NO-3NC Contact
Contact
Contactors
Terminal Blocks
Circuit Breakers
814 www.IDEC.com
Relays & Sockets RF1V
6.5
6.5
5
5
10 7 8 14 12
9 M3 Terminal 13 11
Screw M3 Terminal
10 8 Screw
6
5 9 7
75
75
Signaling Lights
4 6 4
6.2 6.2
3 2 1 5 2 1 3
R2
6.5
R2
6.5
6.3 6.3
5.3
5.3
29.8
22.4 35.4
4
35.4
4
Timers
0.2
22
14.5 0.2
(Top View)
(Top View)
Contactors
Terminal Blocks
Circuit Breakers
15 max.
15 max.
60 max.
50 max.
Signaling Lights
40 max.
40 max.
6.2
3.6
6.2
3.5
3.6
3.5
(13) (13)
0.6
(13) 0.8
(13) 6.93 0.4 10.16
0.6
0.8
6.93 0.4 13.97 5.08
10.16
13.97 5.08 5.08 5.08
5.08 11.43 5.08
11.43
Relays & Sockets
3-3.2 holes for M3 self-tapping screws 3-3.2 holes for M3 self-tapping screws
le
ho le
39.90.1 .1 49.90.1 ho
1 .1
4.10.1 24.8 0.1 - 4.10.1 24.80.1 -1
10 14
1 3 4 7 8 1 3 4 7 8 11 12
2 5 6 9 10 2 5 6 9 10 13 14
10.16 0.1
816 www.IDEC.com
Relays & Sockets Operating Instructions
Operating Instructions
Signaling Lights
operating characteristics as shown below. reliability, contact life, and noise suppression, use of a surge absorbing circuit
Pulsation is recommended. Note that the release time of the load becomes slightly
longer. Check the operation using the actual load. Incorrect use of a contact
Smoothing
protection circuit will adversely affect switching characteristics. Four typical
Emin Emax Emean DC
Capacitor examples of contact protection circuits are shown in the following table:
+
R Relay Emax Emin
Ripple Factor (%) 100%
Emean This protection circuit can be used when the load
Emax = Maximum of pulsating current impedance is smaller than the RC impedance in an
Emin = Minimum of pulsating current
Emean = DC mean value AC load power circuit.
Power Ind. Load
R: Resistor of approximately the same resistance
RC
consideration is needed for the circuit design. As shown in the incorrect This protection circuit can be used for both AC and
circuit below, leakage current (Io) flows through the relay coil while the relay DC load power circuits.
is off. Leakage current causes coil release failure or adversely affects the R: Resistor of approximately the same resistance
vibration resistance and shock resistance. Design a circuit as shown in the value as the load
C: 0.1 to 1 F
correct example.
This protection circuit can be used for DC load power
Incorrect Correct + circuits. Use a diode with the following ratings.
Diode
Timers
Io
Forward current: More than the load current
This protection circuit can be used for both AC and
4. Surge suppression for transistor driving circuits: DC load power circuits.
Varistor
Contactors
a Zener voltage slightly higher than the power voltage.
This protection circuit is very effective in arc suppression when
Back emf
suppressing diode opening the contacts. But, the capacitor is charged while the
+
C
Load contacts are opened. When the contacts are closed, the capacitor
Power
R Relay is discharged through the contacts, increasing the possibility of
contact welding.
Generally, switching a DC inductive load is more difficult than switching a DC Terminal Blocks
resistive load. Using an appropriate arc suppressor, however, will improve the
switching characteristics of a DC inductive load.
Soldering
1. When soldering the relay terminals, use a soldering iron of 30 to 60W, and
quickly complete soldering (within approximately 3 seconds).
Circuit Breakers
Other Precautions
1. General notice: 2. UL and CSA ratings may differ from product rated values determined by IDEC.
To maintain the initial characteristics, do not drop or shock the relay.
3. Do not use relays in the vicinity of strong magnetic field, as this may affect
The relay cover cannot be removed from the base during normal operation. To relay operation.
maintain the initial characteristics, do not remove the relay cover.
Use the relay in environments free from condensation, dust, sulfur dioxide
(SO2), and hydrogen sulfide (H2S).
Signaling Lights
Make sure that the coil voltage does not exceed applicable coil voltagerange.
Safety Precautions
Turn off the power to the relay before starting installation, removal, wiring, Precautions for the RU Relays
maintenance, and inspection of the relays. Failure to turn power off may
cause electrical shock or fire hazard. Before operating the latching lever of the RU relay, turn off the power to
theRU relay. After checking the circuit, return the latching lever to the origi-
Relays & Sockets
Observe specifications and rated values, otherwise electrical shock or fire nalposition.
hazard may be caused.
Do not use the latching lever as a switch. The durability of the latching lever
Use wires of the proper size to meet voltage and current requirements. Tight- is a minimum of 100 operations.
en the terminal screws on the relay socket to the proper tightening torque.
When using DC loads on 4PDT relays, apply a positive voltage to terminals of
Surge absorbing elements on AC relays with RC or DC relays with diode are neighboring poles and a negative voltage to the other terminals of neighbor-
provided to absorb the back electromotive force generated by the coil. When ing poles to prevent the possibility of short circuits.
the relay is subject to an excessive external surge voltage, the surge absorb-
ing element may be damaged. Add another surge absorbing provision to the DC relays with a diode have a polarity in the coil terminals. Apply the DC volt-
relay to prevent damage. age to the correct terminals.
Timers
Contactors
Terminal Blocks
Circuit Breakers
818 www.IDEC.com
Relays & Sockets RSC
Signaling Lights
Back-to-back SCR output
Direct Bond Copper (DBC) substrate construction
Built-in transient protection (TVS)
100k-cycle UL508 endurance rating
UL Recognized, TUV Approved, CE Marked
Lead free and RoHS compliant
EMC (Level 3) & IEC 62314 compliant
Timers
4-32V DC 30A RSCDN-30A
Storage temperature (C) -40 to +100
45A RSCDN-45A
Input-to-Output isolation voltage (Vrms) 4200
20A RSCA1N-20A
90-140V AC 30A RSCA1N-30A Input/Output to ground isolation voltage
4000
(Vrms)
45A RSCA1N-45A
General Characteristics
Contactors
Heat sink material Anodized aluminum black
30A RSCA2N-30A Protection (IEC 60529) - Casing IP20
Input terminal wire size (stranded and
16 AWG to 24 AWG
solid)
45A RSCA2N-45A*
Input terminal tightening torque (Nm) 0.5
*Input control voltage is 180-260V AC. Output terminal wire size (stranded) 8 AWG to 16 AWG
Output terminal wire size (solid) 10 AWG to 16 AWG
Terminal Blocks
Output terminal tightening torque (Nm) 1.3
Weight (g) 225 400
Circuit Breakers
Specifications cont
Switches & Pilot Lights
Level 3
ENV 50140/204 (IEC 1000-4-3)
Immunity to rapid transient
Level 3
bursts to IEC 1000-4-4
Immunity to shock waves ac-
Level 3
cording to IEC/EN 61000-4-5
Immunity to radio frequency in
Relays & Sockets
Input Specifications
820 www.IDEC.com
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
RSC
821
Dimensions (mm)
20A/30A Models
Relays & Sockets
Key features:
Input status LED Indicator
Dual SCR output
Direct bond copper substrate
Internal transient protection built-in snubber
EMC compliant (level 3)
Photo isolation
1200 Volt blocking voltage
Signaling Lights
25A RSSAN-25A
AC Input Pick Up Voltage 4V DC 90V AC
90-280V AC 50A RSSAN-50A
Drop Out Voltage 1V DC 10V AC
75A RSSAN-75A
Dielectric Strength
Timers
822 www.IDEC.com
Relays & Sockets RSS
Recommended Loads
Recommended Loads
SSR Rating at 120V AC at 240V AC
10A 500VA 1KVA
Signaling Lights
25A 1KVA 2KVA
50A 2KVA 4KVA
Heater Loads
When using solid state relays for driving heaters where the load is switched on and off rapidly and continuously, severe thermal stress will result. In such cases, use
an SSR relay at no more than 75% of the rating.
Timers
RSS relays use high-noise immunity circuitry with a built-in snubber to handle the electrical noise generated by inductive loads.
Recommended Loads
Contactors
50A 3,800W 7,500W
RSS series relays provide a highly reliable means of switching AC loads when applied properly. Read the technical notes on the following page prior to installing
solid state relays.
Terminal Blocks
Circuit Breakers
Lamp Loads
Zero voltage switching is ideal for driving incandescent lamps, since the cold filament will not be subjected to a large inrush current. Using a zero-switched SSR will
reduce inrush current and prolong lamp life.
Recommended Loads
SSR Rating at 120V AC at 240V AC
Relays & Sockets
824 www.IDEC.com
Relays & Sockets RSS
Technical Notes
If SSRs must be installed in an environment subject to high temperatures or poor ventilation, or if SSRs are mounted collectively, reduce the load current so that it
does not approach the ambient temperature-load current recommendation. (See the Temperature Derating Curves on the following page.)
When SSRs are used with inductive loads, suppress the inrush current to half of the peak surge current.
Heat Sinks
Signaling Lights
Heat sinks are recommended for all solid state relays depending on ambient temperature and mounting position. The recommended heat sink dimensions and mate-
rial are shown in the table:
Using a thermal compound between the base of the SSR and the heat sink for heat dissipation is recommended.
Wiring
Locate SSRs as far from motor leads as possible to prevent malfunction from induced current.
Use shielded wires for input leads when they are exposed to a source of induced current.
Timers
Mounting
Provide sufficient ventilation.
Use #6 32 screws, flat washers, and lock washers to secure mounting on heat sinks.
Vertical mounting is recommended to allow air to flow unimpeded. Horizontal or inverted mounting is possible, but the SSR must be derated according to the derating
curves on the following page.
Contactors
Additional Information
Do not exceed the load voltage and current specifications.
A small-capacity load may not turn off due to the leakage current present after the SSR has turned off. If this is the case, use a resistor in parallel with the load to
shunt the leakage current.
Observe the polarity of input terminals. Failure to do so may cause damage to the SSR.
When the SSR output is subjected to a higher than rated voltage, a varistor or other element should be connected to the output terminals to absorb the over-voltage. Terminal Blocks
When the input signal contains a ripple voltage, the lowest ripple amplitude should exceed the minimum pick-up voltage of 4V.
Over 4V
Lowest Voltage
0V
Circuit Breakers
0.5C/W
0.7C/W
1.0C/W
1.5C/W
Timers
Contactors
826 www.IDEC.com
Relays & Sockets RSS
Dimensions (mm)
1 2
1.88" (47.6mm)
2.65" (67.31mm)
2.25" (57.2mm)
1.7" (43.2mm)
Signaling Lights
2.4" (6.96mm)
-4 3+
0.2"
1.0" (25.4mm) (4.8mm)
6-32 Pan Head Screw
Small Saddle Clamp
0.5" (12.70mm)
0.09" (2.3mm)
0.37" (9.40mm)
Timers
Contactors
Terminal Blocks
Circuit Breakers
828
www.IDEC.com
Relays & Sockets