Relay Socket Family

Download as pdf or txt
Download as pdf or txt
You are on page 1of 76

Switching & Controls

Switches & Pilot Lights


Selection Guide........................................... 754

General Purpose Relays.............................. 756


RV8H Series 6mm Interface Relays............... 756
RJ Series Slim Power Relays......................... 759
RQ Series PCB Relays.................................... 769

Signaling Lights
RH Series Compact Power Relays................. 773
RR Series Power Relays................................. 783
RU Series Universal Relays........................... 790
RY/RM Series Miniature Relays.................... 799
RF1V Force Guided Relays............................. 810

Solid State Relays....................................... 819


RSC Series Solid State Relays....................... 819

Relays & Sockets


RSS Series Panel Mount Solid State
Relays............................................................. 822

Relays

Timers
Contactors
Terminal Blocks

www.IDEC.com/relays
Circuit Breakers

Table of Contents LED Machine Lighting - Pg. 1 Automation & Sensing - Pg. 27 Safety - Pg. 255 Switching & Controls - Pg. 449 Index - Pg. 933
Selection Guide Relays & Sockets

Selection Guide
Switches & Pilot Lights

General Purpose Relays


Series RV8H Series RJ Series RQ Series RH Series RR Series

Appearance
Signaling Lights

Page 756 759 769 773 783


Contact Configuration 1 form C (SPDT) SPDT, SPST, DPDT, DPST SPDT, DPDT SPDT, DPDT, 3PDT, 4PDT SPDT, DPDT, 3PDT
Terminal Screw Blade or PCB PCB Blade or PCB Pin or Blade
SPDT: 12A/16A, 30V 10A, 30V DC/240V AC 10A, 30V DC/ 240V AC
Contact Rating SPDT: 12A, 16A
6A 30VDC/250VAC DC/250V AC 1/3HP, 240V AC 1/3HP, 240V AC
(resistive) DPDT: 8A
DPDT: 8A, 30V DC/250V AC 1/6HP, 120V AC 1/4HP, 120V AC
Silver-Nickel with gold
Contact Material Silver-Nickel alloy Silver-Nickel alloy Silver-Cadmium Oxide Silver
plating
Relays & Sockets

Series RU Series RY/RM Series RF1V Series

Appearance

Page 790 799 810


Contact Configuration DPDT, 4PDT DPDT, 4PDT DPDT 4PDT or 6PDT
Timers

Terminal Blade or PCB Blade or PCB


DPDT: 10A, 30V DC/250V AC
Contact Rating RY: DPDT: 3A, 30V DC/240V AC 6A, 250V AC
4PDT: 6A, 30V DC/250V AC 5A, 30V DC/240V AC
(resistive) 4PDT: 5A, 30V DC/240V AC 6A 250V DC
1/10 HP, 240V AC
DPDT Silver Tin Oxide Indium
Contact Material Gold plated silver Silver Silver alloy
4PDT Gold-Silver Alloy on Silver
Contactors
Terminal Blocks
Circuit Breakers

754 www.IDEC.com
Relays & Sockets Selection Guide

Selection Guide cont

Switches & Pilot Lights


Bifurcated Contacts Relays
Series RJ22 Series RU42 Series

Appearance

Signaling Lights
Page 759 790
Contact Configuration DPDT 4PDT
Terminal Blade or PCB Blade or PCB
Contact Rating
1A 250V AC/30V DC 3A 250V AC/30V DC
(resistive)
Contact Material Gold clad Gold Silver Alloy on Silver

Latching Relays

Relays & Sockets


Series RR2KP Series RY2KS Series

Appearance

Page visit www.IDEC.com/relays


Contact Configuration DPDT DPDT

Timers
Terminal Pin Blade
Contact Rating 10A, 30V DC 3A, 30V DC
(resistive) 10A, 240V AC 3A, 240V AC
Contact Material Silver Silver, gold-plated

Solid State Relays


Series RSC Series RSS Series

Contactors
Appearance

Terminal Blocks
Page 819 822
Output Configuration 1 Form A (SPST-NO) 1 Form A (SPST-NO)
20A, 30A, 45A 10A, 25A, 50A, 75A, 90A
Output Rating
48 - 600V AC 48 - 660V AC
Output Dual SCR (zero crossing)
Circuit Breakers

800-262-IDEC (4332) USA & Canada 755


RV8H Relays & Sockets

RV8H Series 6mm Interface Relays


Switches & Pilot Lights

Key features:
Space-saving 6mm width
Only 70mm in height from DIN rail
Gold-plated contacts
Pre-assembled relay and DIN mount socket
Universal screw terminals (flat and Phillips)
Spring clamp terminals
Universal AC/DC socket with built-in surge suppression and green LED
Lever for easy locking and removal of relay
Signaling Lights

Wide input voltage range: 6 to 240V


High dielectric strength and impulse withstand voltages
Reverse Polarity protected
400V AC maximum switching voltage
(when using combination of
1500VA maximum switching power RV relay and SV socket)

RoHS compliant

Part Numbers
Relays & Sockets

Complete Part Numbers (Relay & Socket) Accessories Marking Plates


Part Number Item Color Part Number Item Part Number Engraving
(Standard Stock in bold) SV9Z-PW10 blank
Coil Voltage Jumper (20 combs1) Black SV9Z-J20B
Screw Ter- Spring Clamp SV9Z-PW10-j1-10 1-10
Gray SV9Z-J20W
minal Terminal

Vertical Orientation
SV9Z-PW10-j11-20 11-20
6V RV8H-L-D6 RV8H-S-D6 Blue SV9Z-J20S
SV9Z-PW10-j21-30 21-30
9V RV8H-L-D9 RV8H-S-D9 Spacer (circuit separator)2
SV9Z-PW10-j31-40 31-40
DC 12V RV8H-L-D12 RV8H-S-D12 SV9Z-PW10-j41-50 41 -50
SV9Z-SA2W
18V RV8H-L-D18 RV8H-S-D18 SV9Z-PW10-j51-60 51-60
Timers

24V RV8H-L-D24 RV8H-S-D24 SV9Z-PW10-j61-70 61-70


12V RV8H-L-AD12 RV8H-S-AD12 SV9Z-PW10-j71-80 71-80
Screwdriver
18V RV8H-L-AD18 RV8H-S-AD18 SV9Z-PW10-j81-90 81-90
Blue BC1S-SD0

Horizontal Orientation
24V RV8H-L-AD24 RV8H-S-AD24 SV9Z-PW10-j91-100 91-100
AC/ SV9Z-PW10-jA-J A-J
48V RV8H-L-AD48 RV8H-S-AD48
DC 1. Jumper combs come with 20 points, if shorter lengths are
60V RV8H-L-AD60 RV8H-S-AD60 needed simply cut off the excess points. SV9Z-PW10-jK-T K-T
2. Width of spacer: 2mm
110V - 125V RV8H-L-AD110 RV8H-S-AD110 SV9Z-PW10-jU-Z U-Z
Note: When using a cut jumper, please use a spacer on the cut
Contactors

220V - 240V RV8H-L-AD220 RV8H-S-AD220 side. For additional information see instruction sheet. SV9Z-PW10-jGROUND GROUND

Standard stock models in bold.


SV9Z-PW10-jAC AC
1. In place of j insert orientation code: V=Vertical, H=Horizontal
2. Each unit has 10 pieces (marking plates).

Replacement Parts
Complete Part Applicable Socket Applicable Relay Complete Part Applicable Socket Applicable Relay
Number Part Number Part Number Number Part Number Part Number
RV8H-L-D6 RV1H-G-D5 RV8H-S-D6 RV1H-G-D5
Terminal Blocks

RV8H-L-D9 RV1H-G-D9 RV8H-S-D9 RV1H-G-D9


RV8H-L-D12 SV1H-07L-5 RV1H-G-D12 RV8H-S-D12 SV1H-07LS-5 RV1H-G-D12
RV8H-L-D18 RV1H-G-D18 RV8H-S-D18 RV1H-G-D18
Spring Clamp Terminals
Screw Terminals

RV8H-L-D24 RV1H-G-D24 RV8H-S-D24 RV1H-G-D24


RV8H-L-AD12 RV1H-G-D12 RV8H-S-AD12 RV1H-G-D12
RV8H-L-AD18 SV1H-07L-1 RV1H-G-D18 RV8H-S-AD18 SV1H-07LS-1 RV1H-G-D18
RV8H-L-AD24 RV1H-G-D24 RV8H-S-AD24 RV1H-G-D24
Circuit Breakers

RV8H-L-AD48 RV1H-G-D48 RV8H-S-AD48 RV1H-G-D48


SV1H-07L-2 SV1H-07LS-2
RV8H-L-AD60 RV1H-G-D60 RV8H-S-AD60 RV1H-G-D60
RV8H-L-AD110 SV1H-07L-3 RV1H-G-D60 RV8H-S-AD110 SV1H-07LS-3 RV1H-G-D60
RV8H-L-AD220 SV1H-07L-4 RV1H-G-D60 RV8H-S-AD220 SV1H-07LS-4 RV1H-G-D60

756 www.IDEC.com
Relays & Sockets RV8H

Specifications

Switches & Pilot Lights


Number of Poles 1 pole Contact Ratings
Contact Configuration 1 form C (SPDT) Allowable contact
Resistive load 1500VA, 180W
power
Contact material AgNi (Au plating)
Rated Load Resistive load 250V AC 6A, 30V DC 6A
Degree of Protection IP20
Allowable Switching Current 6A
Dielectric Between contact and coil 4,000V AC for 1min
Allowable Switching Voltage 400VAC, 125VDC
strength Between pole 1,000V AC for 1min
Allowable Switching Power 1500VA, 180W
NO: Frequency 10 to 55Hz, Amplitude 1.0mm
Operating extremes Minimum Applicable Load 6VDC/10mA

Signaling Lights
Vibration NC: Frequency 10 to 55Hz, Amplitude 0.4mm
Resistance NO: Frequency 10 to 55Hz, Amplitude 0.5mm
Damage limits
NC: Frequency 10 to 55Hz, Amplitude 0.2mm
NO: 49m/s2 (5G)
Shock Operating extremes
NC: 29.4m/s2 (3G)
Resistance
Damage limits 980m/s2 (10G)
Mechanical Life (without load) Over 10,000,000 operations
-40 to +70C without freezing
Operating Temperature (-40 to +55C for RV8H-L-AD110, AD220,

Relays & Sockets


RV8H-S-AD110, AD220)
Operating Humidity 5 to 85% (without condensation)
Weight 30g (RV8H-L), 26g (RV8H-S)
*Operation frequency 1800 operations per hour.

Coil Ratings
Circuit Circuit Operating Characteristics
Rated Current Power
Rated Voltage AC Resistance DC Resistance Pickup Dropout Maximum
+-15% (mA) Consumption
+-10% () +-10% () Voltage Voltage Allowable voltage

Timers
6V 35 - 170 0.21W
9V 18.6 - 485 0.2W
DC 12V 14.6 - 820 110% 0.2W
18V 11.6 - 1550 0.2W
24V 10.6 - 2270 0.25W
12V 15.5 755 800 0.2W
90% max 7% min
18V 13.3 1365 1345 0.25W

Contactors
24V 13.7 1730 1790 0.33W
AC/DC 48V 4 11880 12230 110% 0.2W
60V 3.4 17600 17910 0.2W
110V - 125V 3.4 - 3.9 31790 - 31890 32450 - 32900 0.5W
220V - 240V 3.3 - 3.6 65670 - 66070 65940 - 68570 0.85W

RV1H Relay

Terminal Blocks
Contact Ratings Maximum Switching Power AC Maximum Switching Power DC

Resistive AC Resistive load

Inductive AC Inductive load (p. f=0.35)


Contact Current (A)

Contact Current (A)


Contact Current (A)

DC Resistive load
Circuit Breakers

DC Inductive load
(L/R = 56ms)

Contact Voltage (V) Contact Voltage (V) Contact Voltage (V)

800-262-IDEC (4332) USA & Canada 757


RV8H Relays & Sockets

Dimensions (mm)
Switches & Pilot Lights

RV1H-G Relay RV8H-L Screw Terminal


28

A1(+) Coil 14 NO
15.0

69.6
Signaling Lights

74.2
0.5

11 (13+) COM

A2(-) Coil
3.5

1.2 0.5 1
5 0.9 5.04 5.04
3.78 16.38 12 NC

35 6.1
Note: Drawings are not to scale.
88
Relays & Sockets

Internal Connection (bottom view)

A1 A2 12 11 14
(13+)

SV9Z-SA2W RV8H-S Spring Clamp Terminal


Timers

14 NO
A1(+) Coil
66.8
71.4




11 (13+) COM
A2(-) Coil
Contactors

12 (NC)
35
96.7 2  


SV9Z-PW10 Marking Plate Placement


3 Cut 0DUNLQJ3ODWH
Terminal Blocks

16.5

10.5

,QVHUW
1 6 59+
86.5

SV9Z-J20*
115.9
6.1
6
12.3
Circuit Breakers

120 2.8

*Available in black, gray and blue.

758 www.IDEC.com
Relays & Sockets RJ

RJ Series Slim Power Relays

Switches & Pilot Lights


Key features:
Compact and rugged power relays. Large switching capacity
Compact housing only 12.7-mm wide.
Large contact rating
RJ1 (1-pole): 16A (UL general use rating @250V AC)
RJ2 (2-pole): 8A
Non-polarized LED indicator available on blade type. IDECs unique light guide structure enables
high visibility of coil status from any direction.
The smallest width for 2-pole/bifurcated contact relay

Signaling Lights
Excellent electrical and mechanical life.
Electrical life: 200,000 operations (AC load)
Mechanical life: 30 million operations (AC coil)
RoHS directive compliant (EU directive 2002/95/EC). Contains no lead, cadmium, mercury, hexavalent chromium, PBB or PBDE.
Diode model:
Diode reverse withstand voltage: 1000V
UL recognized, CSA certified, EN compliant.

UL508 CSA C22.2 No. 14 EN61810-1

Relays & Sockets


UL File No. E55996 1608322 VDE (REG.-Nr B312)
CSA File No. LR35144

EN61810-1
EC Low Voltage Directive

Part Number Selection


Coil Voltage Code
Style Terminal Contact Model Part Number
(Standard Stock in bold)
Standard RJ1S-C-0 A24, A110, A120, A220, A240,
with LED RJ1S-CL-0 D12, D24, D48, D100
SPDT

Timers
with Surge Suppresion Diode RJ1S-CD-0
D12, D24, D48, D100
with LED & Surge Suppresion Diode RJ1S-CLD-0
Standard RJ2S-C-0 A24, A110, A120, A220, A240,
with LED RJ2S-CL-0 D12, D24, D48, D100
Blade
with Surge Suppresion Diode RJ2S-CD-0
D12, D24, D48, D100
with LED & Surge Suppresion Diode RJ2S-CLD-0
DPDT

Contactors
Standard Bifurcated contacts (without LED indicator) RJ22S-C-0 A12, A24, A120, A240,
Bifurated contacts (with LED indicator) RJ22S-CL-0 D5, D12, D24, D100

Bifurcated contacts diode (without LED indicator) RJ22S-CD-0


D5, D12, D24, D48, D100
Bifurcated contacts diode (with LED indicator) RJ22S-CLD-0
Standard RJ1V-C-0
SPDT
High Capacity RJ1V-CH-0
Standard RJ1V-A-0

Terminal Blocks
A24, A110, A120, A220, A240,
SPST-NO
High Capacity RJ1V-AH-0 D5, D6, D12, D24, D48, D100
PCB
DPDT Standard RJ2V-C-0
DPST-NO Standard RJ2V-A-0
DPDT Bifurcated contacts RJ22V-C-0 A12, A24, A120, A240,
DPST-NO Bifurcated contacts RJ22V-A-0 D5, D12, D24, D48, D100

Ordering Information
Circuit Breakers

When ordering, specify the Part No. and coil voltage code:
(example) RJ1S-C- A120
Part No. Coil Voltage Code

800-262-IDEC (4332) USA & Canada 759


RJ Relays & Sockets

Coil Voltage Table


Switches & Pilot Lights

Coil Voltage Code A12 A24 A110 A120 A220 A240 D5 D6 D12 D24 D48 D100
Coil Rating 12V AC 24V AC 110V AC 120V AC 220V AC 240V AC 5V DC 6V DC 12V DC 24V DC 48V DC 100-110V DCV DC

Sockets Replacement Hold Down Springs


Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount PCB Mount Part Number Used With Socket
RJ1S (Std) SJ1S-05BW SJ1S-07LW SJ1S-61 SJ1S-05BW, SJ1S-07LW,
Models

SJ9Z-CM
Blade

SJ2S-05BW, SJ2S-07LW
RJ2S (Std)/RJ22S SJ2S-05BW SJ2S-07LW SJ2S-61 SQ9Z-C SQ1V-07B, SQ2V-07B
Signaling Lights

RJ1V (Std) SQ1V-07B* SQ1V-63* SQ9Z-C63 SQ1V-63, SQ2V-63


Models
PCB

RJ1V (HC) RJ2V/RJ22V SQ2V-07B* SQ2V-63* Jumpers for SJ Sockets


Poles Part Number Quantity
2 SJ9Z-JF2
Must
5 SJ9Z-JF5 purchase in
8 SJ9Z-JF8 quantities
of 10.
SJ9Z-JF10
Relays & Sockets

10
Shown with optional marking plate.

*Hold-down clip or spring must be removed to use with RJ PCB relays.

Accessories
Item Appearance Use with Part No. Remarks
The BNDN1000 is designed to accommodate DIN mount sockets.
Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).
Timers

DIN Rail End


DIN rail BNL5 9.1 mm wide.
Stop

Marking Plate Finger safe sockets (ONLY) SJ9Z-PWPN10 10 pieces per pack
Contactors
Terminal Blocks
Circuit Breakers

760 www.IDEC.com
Relays & Sockets RJ

Specifications

Switches & Pilot Lights


Model RJ1 RJ2 RJ22S RJ22V
Number of Poles 1-pole 2-pole
DPDT (bifurcated),
Contact Configuration SPDT DPDT DPDT bifurcated contacts
DPST-NO (bifurcated)
Contact Material Silver-nickel alloy AgNi (gold clad)
Degree of Protection IP40 Flux-tight structure
Contact Resistance (initial value) 1
50 m maximum
Operating Time 2 15ms maximum (with diode: 20 ms maximum)

Signaling Lights
Release Time 2 10 ms maximum (with diode: 20 ms maximum)
Between contact and coil 5000V AC, 1 minute
Dielectric
Between contacts of the same pole 1000V AC, 1 minute
Strength
Between contacts of different poles 3000V AC, 1 minute
Vibration Operating extremes 10 to 55 Hz, amplitude 0.75 mm
Resistance Damage limits 10 to 55 Hz, amplitude 0.75 mm
Shock Operating extremes NO contact: 200 m/s2, NC contact: 100 m/s2

Relays & Sockets


Resistance Damage limits 1000 m/s2
AC load: 200,000 operations minimum AC load: 100,000 operations minimum
(operation frequency 1800 operations per hour) (operation frequency 1,800 per hour)
Electrical Life (rated load)
DC load: 100,000 operations minimum DC load: 200,000 operations minimum
(operation frequency 1800 operations per hour) (operation frequency 1,800 per hour)
AC coil: 30,000,000 operations minimum (operation AC load: 10 million operations minimum
frequency 18,000 operations per hour) (operating frequency 18,000 operations per hour)
Mechanical Life (no load)
DC coil: 50,000,000 operations minimum (operation DC load: 20 million operations minimum
frequency 18,000 operations per hour) (operating frequency 18,000 operations per hour)
Operating Temperature 3 40 to +70C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)

Timers
19g (blade type), 17g (PCB form C type),
Weight (approx.) 19g DPDT: 17g, DPST-NO: 16g
16g (PCB form A type)

Note: Above values are initial values.


1. Measured using 5V DC, 1A voltage drop method.
2. Measured at the rated voltage (at 20C), excluding contact bounce time.
3. 100% rated voltage.

Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 761


RJ Relays & Sockets

Coil Ratings
Switches & Pilot Lights

Rated Current (mA)


Coil Operating Characteristics2
Coil 15% (at 20C)
Resistance Power
Rated Voltage Voltage Without LED1 With LED1 (ohms)10% Pickup Dropout Maximum Consumption
Code
50Hz 60Hz 50Hz 60Hz (at 20C) Voltage Voltage Allowable Voltage3

Blade 24V A24 43.9 37.5 47.5 41.1 243


& PCB 120V A120 8.8 7.5 8.7 7.4 6,400 0.9VA (60Hz)
Models 240V A240 4.3 3.7 4.3 3.7 25,570
12V A12 87.3 75.0 91.1 78.8 62.5 80% max 30% min 140%
AC

Approx.
Bifurcated 24V A24 43.9 37.5 47.5 41.1 243 1.1VA (50Hz)
Signaling Lights

Models 120V A120 8.8 7.5 8.7 7.4 6,400 0.9 to 1.2VA
240V A240 4.3 3.7 4.3 3.7 25,570 (60Hz)
Rated Current (mA) Coil
Coil Operating Characteristics2
15% (at 20C) Resistance Power
Rated Voltage Voltage
(ohms)10% Pickup Dropout Maximum Consumption
Coil Ratings

Code Without LED 1


With LED 1
(at 20C) Voltage Voltage Allowable Voltage3
12V D12 44.2 48.0 271
Blade 24V D24 22.1 25.7 1,080 170%
70% max 10% min 0.53W
Models
Relays & Sockets

48V D48 11.0 10.7 4,340


100-110V D100 5.3 - 5.8 5.2 - 5.7 18,870 160%
5V D5 106 47.2
6V D6 88.3 67.9
PCB 12V D12 44.2 271 170%
70% max 10% min 0.53-0.64W
DC

Models 24V D24 22.1 1,080


48V D48 11.0 4,340
100-110V D100 5.3 - 5.8 18,870 160%
5V D5 106 110 47.2
12V D12 44.2 48.0 271
Bifurcated 170% Approx.
24V D24 22.1 25.7 1,080 70% max 10% min
Timers

Models 0.53 to 0.64W


48V D48 11 10.7 4,340
100-110V D100 5.3-5.8 5.2-5.7 18,870 160%
1. LED Indicator is only available on Blade or Bifurcated relays.
2. Operating characteristics are at 20C.
3. The maximum allowable voltage is the maximum value which can be applied to the relay coils.

Contact Ratings
Allowable Contact Power Rated Load Allowable Allowable Minimum
Model Contact Resistive Resistive Inductive Load Switching Switching Applicable
Contactors

Inductive Load Voltage Current Voltage Load


Load Load cos=0.3 L/R=7ms
NO 3000V AC 1875VA 250V AC 12A 7.5A 16A AC250V DC5V
1 pole
DC30V 100mA
Blade Models

NC 3000V AC 1875VA 250V AC 12A 7.5A 6A


NO 2000V AC 1000VA 250V AC 8A 4A 4A AC250V DC5V
2 poles
NC 2000V AC 1000VA 250V AC 8A 4A 4A DC30V 10mA
2 poles NO 250VA AC 100VA AC 250V AC 1A 0.4A 250V AC 1V DC
1A
(bifurcated contacts) NC 30W DC 15W DC 30V DC 1A 0.5A 125V DC 100A
3000V AC 1875VA 250V AC 12A 7.5A
Terminal Blocks

Contact Ratings

NO 12A
Standard 360W 180W 30V DC 12A 6A AC250V DC5V
Type 3000V AC 1875VA 250V AC 12A 7.5A DC125V 100mA
NC 6A
180W 90W 30V DC 6A 3A
1 pole
4000V AC 2000VA 250V AC 16A 8A
High NO 16A
480W 240W 30V DC 16A 8A AC250V DC5V
PCB Models

Capacity
4000V AC 2000VA 250V AC 16A 8A DC125V 100mA
Type NC 8A
240W 120W 30V DC 8A 4A
2000V AC 1000VA 250V AC 8A 4A
NO 8A
Circuit Breakers

240W 120W 30V DC 8A 4A AC250V DC5V


2 poles
2000V AC 1000VA 250V AC 8A 4A DC125V 10mA
NC 4A
120W 60W 30V DC 4A 2A
2 poles NO 250VA AC 100VA AC 250V AC 1A 0.4A 250V AC 1V DC
1A
(bifurcated contacts) NC 30W DC 15W DC 30V DC 1A 0.5A 125V DC 100A

762 www.IDEC.com
Relays & Sockets RJ

Agency Ratings

Switches & Pilot Lights


UL
General Use Resistive
Voltage
RJ1 RJ2 RJ22 RJ22
NO NC NO NC NO NC NO NC
250V AC 16A 6A 8A 4A 1A 1A
30V DC 12A 6A 8A 4A 1A 1A

CSA

Signaling Lights
General Use Resistive Inductive
Voltage
RJ22 RJ1 RJ2 RJ22 RJ1 RJ2 RJ22
NO NC NO NC NO NC NO NC NO NC NO NC NO NC
250V AC 1A 1A 12A 12A 8A 8A 7.5A 7.5A 4A 4A
30V DC 12A 6A 8A 4A 1A 1A 6A 3A 4A 2A 1A 1A

VDE
Resistive AC-15, DC-13*

Relays & Sockets


Voltage
RJ1 RJ2 RJ22 RJ1 RJ2
NO NO NO NC NO NO
250V AC 12A 8A 1A 1A 6A 3A
30V DC 12A 8A 1A 1A 2.5A 2A

*According to the utilization categories of IEC60947-5-1

Socket Specifications
Socket Terminal Electrical Rating Wire Size Torque

Timers
0.6 - 1.0Nm
SJ1S-05BW M3 screw with captive wire clamp 250V, 12A Maximum up to 2 - #14 AWG
DIN Rail/ (Maximum 1.2Nm)
Panel Mount 0.6 - 1.0Nm
SJ2S-05BW M3 screw with captive wire clamp 250V, 8A Maximum up to 2 - #14 AWG
(Maximum 1.2Nm)
0.6 - 1.0Nm
SJ1S-07LW M3 screw with captive wire clamp, fingersafe 250V, 12A Maximum up to 2 - #14 AWG
(Maximum 1.2Nm)
Finger-safe 0.6 - 1.0Nm
DIN Rail/Panel SJ2S-07LW M3 screw with captive wire clamp, fingersafe 250V, 8A Maximum up to 2 - #14 AWG
(Maximum 1.2Nm)
Mount

Contactors
SQ1V-07B M3 screw with box clamp, fingersafe 300V, 12A Maximum up to 2 - #14 AWG 1.0Nm Maximum
SQ2V-07B M3 screw with box clamp, fingersafe 300V, 10A Maximum up to 2 - #14 AWG 1.0Nm Maximum
SJ1S-61 PCB mount 250V, 12A
SJ2S-61 PCB mount 250V, 8A
PCB Mount
SQ1V-63 PCB mount 300V, 12A
SQ2V-63 PCB mount 300V, 12A

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 763


RJ Relays & Sockets

Electrical Life Curve (Resistive Load)


Switches & Pilot Lights

RJ1 RJ1 High Capacity RJ2


1000 1000 1000
( 10,000 operations)

( 10,000 operations)

( 10,000 operations)
250V AC 250V AC 250V AC
Resistive Load Resistive Load Resistive Load
100 (NO contact) 100 (NO contact) 100 (NO contact)

30V DC Resistive Load 30V DC Resistive Load 30V DC Resistive Load


(NO Contact) (NO Contact) (NO Contact)
10 10 10
Signaling Lights

1 1 1
0.1 1 12 0.1 1 16 0.1 1 8
Load Current (A) Load Current (A) Load Current (A)

Maximum Switching Capacity (Resistive Load)


RJ1 RJ1 High Capacity RJ2

AC Resistive (NO Contact)


AC Resistive
Relays & Sockets

AC Inductive AC Resistive (NO Contact)


12 16
Load Current (A)

10 10 10

Load Current (A)


8
Load Current (A)

DC Resistive
(NO Contact)

DC Resistive (NC Contact)


DC Inductive (NO Contact)
1 1 1

DC Inductive
DC Resistive (NO Contact) (NC Contact)
DC Resistive (NO Contact)
0.1
0.1 1 10 100 250
0.1
1 10 100 250 1 10 100 250
Load Voltage (V) Load Voltage (V)
Load Voltage (V)

Operating Temperature and Coil Temperature Rise


Timers

RJ1 (AC Coil, 60 Hz) RJ1 (AC Coil, 50 Hz) RJ1 (DC Coil)
AC Coil (60 Hz) AC Coil (50 Hz) DC Coil
130 130 130
120 120 120
110 110 110
100 100 100
Temperature Rise (C)

90
Temperature Rise (C)

90 90
Temperature Rise (C)

80 80 80
Load Current 12A 1 pole Load Current 12A 1 pole
70 70 70
Contactors

60 60 60 Load Current 12A 1 pole


50 50 50
40 40 40
30 No Load Current 30 No Load Current 30
20 20 20
No Load Current
10 10 10
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)

RJ2 (AC Coil, 60 Hz) RJ2 (AC Coil, 50 Hz) RJ2 (DC Coil)
Terminal Blocks

DC Coil AC Coil (50 Hz) DC Coil


130 130 130
120 120 120
110 110 110
Temperature Rise (C)

100 100 100


90 90 90
Temperature Rise (C)

Temperature Rise (C)

80 80 80
70 70 Load Current 8A 2 poles 70
60 60 60
50 Load Current 8A 2 poles 50 50 Load Current 8A 2 poles
40 40 40
30 30 No Load Current 30
20 No Load Current 20 20 No Load Current
Circuit Breakers

10 10 10
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)

764 www.IDEC.com
Relays & Sockets RJ

Switches & Pilot Lights


RJ22 (AC Coil, 60 Hz) RJ22 (AC Coil, 50 Hz) RJ22 (DC Coil)
AC CoilAC
AC
(60Coil
Coil
Hz)(60
(60Hz)
Hz) AC CoilAC
AC
(50Coil
Coil
Hz)(50
(50Hz)
Hz) DC CoilDC
DCCoil
Coil
130 130
130 130 130
130 130 130
130
120 120
120 120 120
120 120 120
120
110 110
110 110 110
110 110 110
110
100 100
100 100 100
100 100 100
100
Temperature Rise (C)

Rise (C)
(C)

Temperature Rise (C)

Rise (C)
(C)

Temperature Rise (C)

Rise (C)
(C)
90 90
90 90 90
90 90 90
90
80 80
80 80 80
80 80 80
80
Temperature Rise

Temperature Rise

Temperature Rise
70 70
70 70 70
70 70 70
70
Temperature

Temperature

Temperature
60 60
60 60 60
60 60 60
60
50 50
50 50 50
50 50 50
50
40 40
40 40 40
40 40 40
40
30 30 Load current
30 1A x 2 1A
Loadcurrent
Load current poles
1Axx22poles
poles 30 30 Load current
30 Loadcurrent
Load current
1A x 2 1A
poles
1Axx22poles
poles 30 30
30
20 20 No loadNo
20 current
No loadcurrent
load current 20 20 No loadNo
20 No
current
loadcurrent
load current 20 20
20 Load current
Loadcurrent
Load current 1Axx22poles
1A x 2 1A
poles poles

Signaling Lights
10 10
10 10 10
10 10 10
10 No loadNo
No loadcurrent
current
load current
0 0010 20
10 30
10 20 40
20 30 50
30 40 60
40 50 70
50 60 70
60 70 0 0010 2010 20
10 3020 4030
30 5040 50
40 60
50 7060
60 70
70 0 0010 2010 30
10 20 40
20 30 50
30 40 60
40 50 70
50 60
60 70
70
Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
(C) (C)
(C) Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
(C) (C)
(C) Ambient
Ambient
Ambient
Temperature
Temperature
Temperature
(C) (C)
(C)
The above temperature rise curves show characteristics when 100% the rated coil voltage is applied.
The slanted dashed line indicates allowable temperature rise for the coil at different ambient temperatures.

Internal Connection (View from Bottom)

Relays & Sockets


RJ1-C-* Standard RJ2-C/RJ22-C-* Standard RJ22V-A-*
1 1 1
(A1) (A1) (A1)
2(12) 3(11) 4(14) 3(11) 4(14)
2(12) 4(11) 3(14)
5 8 8
(A2) (A2) 7(22) 6(21) 5(24) (A2) 6(21) 5(24)

RJ1-CL-* With LED Indicator RJ2-CL/RJ22-CL-* With LED Indicator


1 1 1 1
(A1) (A1) (A1) (A1)
2(12) 3(11) 4(14) 2(12) 3(11) 4(14)
2(12) 4(11) 3(14) 2(12) 4(11) 3(14)

Timers
5 5 8 8
(A2) (A2) (A2) 7(22) 6(21) 5(24) (A2) 7(22) 6(21) 5(24)

Coil voltage 24V AC/DC and below Coil voltage greater than 24V AC/DC Coil voltage 24V AC/DC and below Coil voltage greater than 24V AC/DC

RJ1-CD-* With Diode RJ2-CD-/ RJ22-CD-* With Diode


1 1
(A1) (A1)
2(12) 3(11) 4(14)

2(12) 4(11) 3(14)


5 + 8 +
7(22) 6(21) 5(24)

Contactors
(A2) (A2)

RJ1-CLD-* With LED Indicator and Diode RJ2-CLD/ RJ22-CLD-* With LED Indicator and Diode
1 1 1 1
(A1) (A1) (A1) (A1)
2(12) 3(11) 4(14) 2(12) 3(11) 4(14)
2(12) 4(11) 3(14) 2(12) 4(11) 3(14)
5 + 5 + 8 + 8 +
(A2) (A2) (A2) 7(22) 6(21) 5(24) (A2) 7(22) 6(21) 5(24)
Coil voltage 24V DC and below Coil voltage greater than 24V DC Coil voltage 24V DC and below Coil voltage greater than 24V DC

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 765


RJ Relays & Sockets

Dimensions (mm)
Switches & Pilot Lights

Blade Relay (mm)


RJ1S RJ2S/RJ22S
Signaling Lights

27.0

28.0

27.0
6.0
5.0

0.5 0.5 0.5 2.6


2.6

ole
4.8 4.8

3h
le
ho

31.1


31.1
3

.2
1
Relays & Sockets

.8
1

4
2
1
1

12.7

12.7
0.5
2

3
5

5
7
28.8 28.8
All dimensions in mm.

PCB Relay (mm)


RJ1V-C-* RJ1V-A-*
4- 4
1.3 -1.3
25.5 max. (25.3)

25.5 max. (25.3)

5- 5 hol h
1.3 -1.3 es oles
25.5 max. (25.3)

25.5 max. (25.3)


Timers

hol 3.5h 3.5 3.5 3.5


es oles

(2.6)

(2.6)

7.5

7.5
(2.6)

(2.6)

7.5

7.5
0.3

0.3

0.3

0.3

0.5 0.5 0.5 0.5 (1.9) (1.9) 20.0 20.0 3.5 3.5
1.0 1.0 0.5 0.5
0.3 0.3 0.5 0.5 (1.9) (1.9) 20.0 20.0 0.3 0.3 0.5 0.5 1.0 1.0
4.0

4.0

13 max.
13 max.
13 max.13 max.
4.0

4.0

29 max.
29(28.8)
max. (28.8) (12.7) (12.7) 29 max.29(28.8)
max. (28.8) (12.7) (12.7)

RJ1V-CH-*/RJ2V-C-* RJ1V-AH-*/RJ2V-A-*
Contactors

6- 6-
1.3 1.3
hol hol
es es
25.5 max. (25.3)

25.5 max. (25.3)

25.5 max. (25.3)

25.5 max. (25.3)

8- 8
1.3 -1.3 5.0 5.0 5.0 5.0
hol h
es oles
(2.6)

(2.6)

7.5

7.5
(2.6)

(2.6)

7.5

7.5
0.3

0.3

0.3

0.3

(1.9) (1.9) 20.0 20.0 5.0 5.0


0.5 0.5 0.5 0.5 1.0 1.0 0.5 0.5
0.5 0.5 1.0 1.0
0.3 0.3 0.5 0.5 (1.9) (1.9) 20.0 20.0 0.3 0.3
13 max.
13 max.
4.0

4.0

13 max. 13 max.
4.0

4.0

29 max.
29(28.8)
max. (28.8) (12.7) (12.7) 29 max. (28.8) (12.7) (12.7)
29 max. (28.8)
Terminal Blocks

RJ22V-C-* RJ22V-A-*
25.5 max.

25.5 max.
(25.3)

(25.3)
0.3

0.3

0.6 0.6 0.6


Circuit Breakers

0.4 0.6 1.1 0.4 0.6 1.1


4.0

4.0

29 max. 13 max. 29 max. 13 max.


(28.8) (12.7) (28.8) (12.7)

766 www.IDEC.com
Relays & Sockets RJ

Dimensions cont (mm)

Switches & Pilot Lights


Standard DIN Rail Mount Sockets
SJ1S-05BW SJ2S-05BW
M3 Terminal Screws M3 Terminal Screws
15.5

15.5

6
6

Signaling Lights
55.7
55.7

29.7
29.7
4.3 71 4 4.3 71 4
2

2
(22) (24)
5 (A2) 3 (14) 8 7 5 6
(A2) (21)
(A1) (A1) (11)
1 2
(12) (11) 4 1 2
(12) (14)
4 3

(TOP VIEW) (TOP VIEW)

Relays & Sockets


Finger-safe DIN Rail Mount Sockets
SJ1S-07LW SJ2S-07LW
M3 Teminal Screws M3 Terminal Screws

5.6 5.6
15.5

15.5
55.7

55.7
49.5

49.5
35.5

35.5
29.7

29.7

Timers
21.5

21.5
4.3 71 3 4.3 71 3

2
2

(A2) (21)
5 (A2) 3 (11) 4 8 5 7 6
(14) (24) (22)
(14) (12)
1 (A1) 2 (12) 1 4 2 3
(A1) (11)
(TOP VIEW) (TOP VIEW)

Contactors
SQ1V-07B SQ2V-07B

Terminal Blocks
Circuit Breakers

A2
11 A2 24 21 22
A1 14 12

A1 14 11 12
(TOP VIEW)
(TOP VIEW)

800-262-IDEC (4332) USA & Canada 767


RJ Relays & Sockets

Dimensions cont (mm)


Switches & Pilot Lights

PC Mount Sockets
SJ1S-61 SJ2S-61

32.5 32.5
(4.3) 20.0 0.1
(4.7) 4.5 0.1 6.0 0.1 5.0 0.1 5.0 0.1

4.0 0.1

14.0
14.0

Terminal Arrangement
Terminal Arrangement

7.0 0.1
(Bottom View)

7.5 0.1
(Bottom View)
1 2 3 1 2 3 4
5 4
8 7 6 5
4.0 0.1 15.0 0.1

5-

8-
1

1
Signaling Lights

.6

.3
36.5
ho

ho
36.5

les

les
1.0
1.0

4.0
4.0

SQ1V-63 SQ2V-63
Relays & Sockets
Timers
Contactors
Terminal Blocks
Circuit Breakers

768 www.IDEC.com
Relays & Sockets RQ

RQ Series PCB Relays

Switches & Pilot Lights


IDEC RQ relays are low-profile, PCB relays in a compact package. Size equals value. RQ relays are small,
yet maintain high contact ratings and long operational life. For larger power needs, a 16A model is also
available.
Key features:
Low profile:
29 x 12.7 x 15 mm
Contact rating:
8A (DPDT) and 12A (SPDT)

Signaling Lights
High capacity model with 16A (SPDT) contact rating
Operational life:
100K cycles at full resistive load
10 million cycles, no load
LED/Diode Plug-in modules available with DIN rail socket
UL Recognized
File No. E59804

Relays & Sockets


R500562600001

Part Number Selection


Part Number
Contact Model Pin Terminal Coil Voltage Code
SPDT 12A

Timers
Basic RQ1V-CM-0 A24, A115, A230, D12, D24

SPDT 16A

HIgh Capacity (HC) RQ1V-CH-0 A24, A115, A230, D12, D24, D110

Contactors
DPDT 8A

Basic RQ2V-CN-0 A24, A115, A230, D12, D24, D110

Terminal Blocks

Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RQ1V-CM A115
Part No. Coil Voltage Code
Circuit Breakers

Coil Voltage Table


Coil Voltage Code A24 A115 A230 D12 D24 D110
Coil Rating 24V AC 110-120V AC 220-240V AC 12V DC 24V DC 110V DC

800-262-IDEC (4332) USA & Canada 769


RQ Relays & Sockets

Sockets Replacement Parts & Accessories


Switches & Pilot Lights

Finger-safe DIN Part Number Description Part Number Description


Relays PCB Mount
Rail Mount
SQ9Z-C Replacement retaining clip SQ9Z-LD Diode plug in modules for DIN socket
RQ1 SQ1V-07B SQ1V-63*
Replacement hold-down spring RC plug-in module (110-230V AC) for
SQ9Z-C63 SQ9Z-LR
RQ2 for SQ PCB sockets DIN socket
SQ2V-07B SQ2V-63*
RQ1 HC
SQ9Z-J8 8 pt jumper for DIN socket SQ9Z-P Replacement marking plate
Signaling Lights

1. *Comes with hold down spring


2. Comes with retaining clip and marking plate.

Accessories
Item Appearance Use with Part No. Remarks
IDEC offers a low-profile DIN rail (BNDN1000). The BNDN1000 is de-
Aluminum
signed to accommodate DIN mount sockets. Made of durable extruded
DIN Rail All DIN rail sockets BNDN1000
aluminum, the BNDN1000 measures 0.413 (10.5mm) in height and 1.37
Relays & Sockets

(1 meter length)
(35mm) in width (DIN standard). Standard length is 39 (1,000mm).

DIN Rail End


DIN rail BNL5 9.1 mm wide.
Stop

Specifications
Model (Contact) RQ1 RQ1 HC RQ2
No. of poles 1 1 2
Timers

Contact Configuration SPDT SPDT DPDT


Contact Rating 12A 16A 8A
Contact Material Silver-Nickel alloy
Contact Resistance 100m max
Operating Time 12 ms
Release Time 8 ms
Contactors

Between contact & coil 5,000VAC, 1 minute


Dielectric Strength
Between contacts 1,000VAC, 1 minute
Damage limits 10-55 Hz, amplitude 1.5mm
Vibration Resistance
Operating extremes 10-55 Hz, amplitude 1.5mm
Damage limits 100m/s2 min (10G)
Shock Resistance
Operating extremes 1,000m/s2 min (100G)
Mechanical Life 10,000,000 operations
Electrical Life @ Full Rated Load 100,000 operations
Terminal Blocks

Operating Temperature -40 to 85 C


Operating Humidity 45 to 85% RH
Dimensions (H x W x D mm) 29 x 12.7 x 15

Weight (Approx.) 15g


Circuit Breakers

770 www.IDEC.com
Relays & Sockets RQ

Coil Ratings

Switches & Pilot Lights


Nominal Current Coil Power Consumption
Rated Voltage Pickup Voltage Dropout Voltage Max Allowable Voltage
50HZ 60HZ Resistance 50HZ 60HZ
12V 33.3mA 360
DC 24V 16.7mA 1,440 0.40W 80% Max 5% Min 130%
110V 4.1mA 26,530
24V 29.75mA 25.35mA 350 0.71W 0.61W
AC 115V 7.65mA 6.3mA 8,100 0.88W 0.73W 80% Max 30% Min 130%

Signaling Lights
230V 3.42mA 2.72mA 32,500 0.79W 0.63W

Socket Specifications
Relays Terminal Electrical Rating Wire Size Torque
SQ1V-07B M3 screw with box clamp 300V, 12A Maximum up to 2 - #14 AWG 1.0Nm Maximum
DIN Rail Sockets
SQ2V-07B M3 screw with box clamp 300V, 8A Maximum up to 2 - #14 AWG 1.0Nm Maximum
SQ1V-63 PCB mount 300V, 12A
PCB Mount Socket
SQ2V-63 PCB mount 300V, 12A

Relays & Sockets


Electrical Life Curves Maximum Switching Capacity
RQ1 & RQ1 High Capacity RQ2 RQ1, RQ1 High Capacity & RQ2

10 7 10 7 300

200

Vol t age of l oad ( V)


100
10 6 10 6

Timers
Oper at i ons

Oper at i ons

RQ2V-CN Dimensions 50
RQ1V-CM Dimensions RQ1V-CH Dimensions 40

10 5 10 5 30

20
RQ2
RQ1 RQ1-HC RQ1
RQ1-HC
10 4 10 4 10
0 2 4 6 8 10 12 14 16 0 2 4 6 8 10 12 14 16 0.1 0.2 0.5 1 2 5 10 20
Load Current (A) Load Current (A) Load Current (A)

Contactors
Internal Connection (View from Bottom)
RQ1 RQ2 RQ1 HC

NC C NO
NC NC C
NO
C NC C NO NO

Terminal Blocks
Bottom View Bottom View
Bottom View
Bottom View
View Bottom View
Circuit Breakers

800-262-IDEC (4332) USA & Canada 771


RQ Relays & Sockets

Dimensions (mm)
Switches & Pilot Lights

RQ1 RQ2/RQ1 HC
Signaling Lights

SQ Socket Domensions
SQ1V-07B SQ2V-07B
Relays & Sockets
Timers

A2 24 21 22
A2
11
A1 14 12 A1 14 11 12

(TOP VIEW) (TOP VIEW)


Contactors

SQ1V-63 PCB Pin Layout SQ1V-63 SQ2V-63 PCB Pin Layout SQ2V-63
Terminal Blocks
Circuit Breakers

772 www.IDEC.com
Relays & Sockets RH

RH Series Compact Power Relays

Switches & Pilot Lights


Key features
SPDT through 4PDT, 10A contacts
Compact power type relays
Miniature power relays with a large capacity
10A contact capacity
Compact size saves space

Signaling Lights
Part Number Selection
Part Number
Blade PCB Termi- Coil Voltage Code
Contact Model
Terminal nal (Standard Stock in bold)
Standard RH1B-U 0 RH1V2-U 0

Relays & Sockets


SPDT With Indicator RH1B-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH1B-UC 0 AC220V, AC240V DC6V, DC12V, DC24V,
DC48V, DC110V
With Indicator and Check Button RH1B-ULC 0
Top Bracket Mounting RH1B-UT 0
With Diode (DC coil only) RH1B-UD 0 RH1V2-UD 0 DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH1B-ULD 0 DC12V, DC24V, DC48V, DC110V
Standard RH2B-U 0 RH2V2-U 0
DPDT
With Indicator RH2B-UL 0 RH2V2-UL 0

Timers
AC6V, AC12V, AC24V, AC110-120V,
With Check Button RH2B-UC 0 AC220-240V
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Check Button RH2B-ULC 0
Top Bracket Mounting RH2B-UT 0
With Diode (DC coil only) RH2B-UD 0 RH2V2-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RH2B-ULD 0 RH2V2-ULD 0
Standard RH3B-U 0 RH3V2-U 0

Contactors
3PDT
With Indicator RH3B-UL 0 RH3V2-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH3B-UC 0 AC220V, AC240V DC6V, DC12V, DC24V,
DC48V, DC110V
With Indicator and Check Button RH3B-ULC 0
Top Bracket Mounting RH3B-UT 0
With Diode (DC coil only) RH3B-UD 0
DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH3B-ULD 0

Terminal Blocks
Standard RH4B-U 0 RH4V2-U 0
4PDT
With Indicator RH4B-UL 0 RH4V2-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RH4B-UC 0 AC220V, AC240V DC6V, DC12V, DC24V, DC48V,
DC110V
With Indicator and Check Button RH4B-ULC 0
Top Bracket Mounting RH4B-UT 0
With Diode (DC coil only) RH4B-UD 0 RH4V2-UD 0
DC6V, DC12V, DC24V, DC48V, DC110V
With Indicator and Diode (DC coil only) RH4B-ULD 0
Circuit Breakers

PCB terminal relays are designed to mount directly to a circuit board without any socket.
Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RH3B-U AC120V
Part No. Coil Voltage Code

800-262-IDEC (4332) USA & Canada 773


RH Relays & Sockets

Sockets (for Blade Terminal Models)


Switches & Pilot Lights

Relays Standard DIN Rail Mount 1 Finger-safe DIN Rail Mount 1 Through Panel Mount PCB Mount
RH1B SH1B-05 SH1B-O5C SH1B-51 SH1B-62
RH2B SH2B-05 SH2B-05C SH2B-51 SH2B-62 1. DIN Rail mount socket
comes with two
RH3B SH3B-05 SH3B-05C SH3B-51 SH3B-62 horseshoe clips. Do
not use unless you
RH4B SH4B-05 SH4B-05C SH4B-51 SH4B-62 plan to insert pullover
wire spring. Replace-
ment horseshoe
clip part number is
Y778-011.
Signaling Lights

Hold Down Springs & Clips


For DIN For Through Panel &
Appearance Item Relay
Mount Socket PCB Mount Socket
RH1B SY2S-02F1 2 2. Must use horseshoe clip when
mounting in DIN mount socket.
RH2B SY4S-02F1 2
Replacement horseshoe clip
Pullover Wire Spring SY4S-51F1 part number is Y778-011.
RH3B SH3B-05F1 2
Relays & Sockets

3. Two required per relay.


RH4B SH4B-02F1 2

Leaf Spring (side latch) RH1B, RH2B, RH3B, RH4B SFA-202 3 SFA-302 3

Leaf Spring (top latch) RH1B, RH2B, RH3B, RH4B SFA-101 3 SFA-301 3

AC Coil Ratings
Rated Current (mA) 15% at 20C Coil Resistance () Operation Characteristics
Timers

Voltage AC 50Hz AC 60Hz 10% at 20C (against rated values at 20C)


(V)
Max. Continuous Pickup Dropout
SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT
Applied Voltage Voltage Voltage
6 170 240 330 387 150 200 280 330 330 9.4 6.4 5.4
12 86 121 165 196 75 100 140 165 165 39.3 25.3 21.2
24 42 60.5 81 98 37 50 70 83 83 153 103 84.5
110 9.6 18.1 21.6 8.4 15.5 18.2 18.2 2,200 1,800
Contactors

9.4- 80% 30%


110-120 8.0-9.2 110%
10.8 maximum minimum
120 8.6 16.4 19.5 7.5 14.2 16.5 16.5 10,800 7,360
220 4.7 8.8 10.7 4.1 7.7 9.1 9.1 10,800 7,360
220-240 4.7-5.4 4.0-4.6 18,820
240 4.9 8.2 9.8 4.3 7.1 8.3 8.3 12,100 9,120

DC Coil Ratings
Terminal Blocks

Coil Resistance () Operation Characteristics


Rated Current (mA) 15% at 20C
Voltage 10% at 20C (against rated values at 20C)
(V) Max. Continuous Pickup Dropout
SPDT DPDT 3PDT 4PDT SPDT DPDT 3PDT 4PDT
Applied Voltage Voltage Voltage
6 128 150 240 250 47 40 25 24
12 64 75 120 125 188 160 100 96
24 32 36.9 60 62 750 650 400 388 Standard coil volt-
80% 10%
110% ages are in BOLD.
48 18 18.5 30 31 2,660 2,600 1,600 1,550 maximum minimum
Circuit Breakers

100-110 8.2-9.0 12,250


110 8 12.8 15 13,800 8,600 7,340

774 www.IDEC.com
Relays & Sockets RH

Contact Ratings UL Ratings

Switches & Pilot Lights


Maximum Contact Capacity Resistive General Use Horsepower Rating
Allowable Contact Power Rated Load Voltage RH1 RH1 RH1
Continuous RH3 RH4 RH3 RH4 RH3 RH4
Model RH2 RH2 RH2
Current Resistive Inductive Voltage Res. Ind.
Load Load (V) Load Load 240V AC 10A 7.5A 7.5A 7A 6.5A 5A 1/3 HP 1/3 HP
110 AC 10A 7A 120V AC 10A 10A 7.5A 7.5A 1/6 HP 1/6 HP
1540VA 990VA
SPDT 10A 220 AC 7A 4.5A 30V DC 10A 10A 7A
300W 210W
30 DC 10A 7A 28V DC 10A
110 AC 10A 7.5A
DPDT CSA Ratings

Signaling Lights
1650VA 1100VA
3PDT 10A 220 AC 7.5A 5A
300W 225W Horse-
4PDT
30 DC 10A 7.5A Resistive General Use power
Note: Inductive load for the rated load cos = 0.3, L/R = 7 ms Voltage Rating
RH1 RH2 RH3 RH4 RH1 RH2 RH3 RH4 RH1, 2, 3
240V AC 10A 10A 7.5A 7A 7A 7A 5A 1/3 HP
TV Ratings 120V AC 10A 10A 10A 10A 7.5A 7.5A 7.5A 1/6 HP
Voltage RH1 RH2 RH3 RH4 30V DC 10A 10A 10A 10A 7A 7.5A

Relays & Sockets


240V AC 10A 10A 7.5A 7.5A
30V DC 10A 10A 10A 10A

AC: cos = 1.0, DC: L/R = 0 ms

Socket Specifications
Sockets Terminal Electrical Rating Wire Size Torque
(Coil) M3 screws 5.5 - 9 inlbs
SH1B-05 250V, 10A Maximum up to 2#12AWG
DIN Rail (contact) M3.5 screws with captive wire clamp 9 - 11.5 inlbs

Timers
Mount SH2B-05
Sockets SH3B-05 M3.5 screws with captive wire clamp 300V, 10A Maximum up to 2#12AWG 9 - 11.5 inlbs
SH4B-05
(coil) M3 screws 5.5 - 9 inlbs
SH1B-05C 250V, 10A Maximum up to 2#12AWG
Finger-safe (contact) M3.5 screws with captive wire clamp, fingersafe 9 - 11.5 inlbs
DIN Rail SH2B-05C
Mount SH3B-05C M3.5 screws with captive wire clamp, fingersafe 300V, 10A Maximum up to 2#12AWG 9 - 11.5 inlbs
SH4B-05C
Through SH1B-51

Contactors
Panel SH2B-51
Solder 300V, 10A
Mount SH3B-51
Socket SH4B-51
SH1B-62 PCB mount 250V, 10A
PCB Mount SH2B-62
Socket SH3B-62 PCB mount 300V, 10A
SH4B-62

Accessories Terminal Blocks


Item Appearance Use with Part No. Remarks
The BNDN1000 is designed to accommodate DIN mount sockets.
Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).

DIN Rail End


Circuit Breakers

DIN rail BNL5 9.1 mm wide.


Stop

Replacement
DIN mount sockets and hold For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
down springs. spring. 2 pieces included with each socket.
Spring Anchor

800-262-IDEC (4332) USA & Canada 775


RH Relays & Sockets

Specifications
Switches & Pilot Lights

Contact Material Silver cadmium oxide


Contact Resistance 1 50m maximum
Minimum Applicable Load 24V DC, 30 mA; 5V DC, 100 mA (reference value)
SPDT
20ms maximum
DPDT
Operating Time 2
3PDT
25ms maximum
4PDT
SPDT
20ms maximum
DPDT
Signaling Lights

Release Time 2
3PDT
25ms maximum
4PDT
SPDT AC: 1.1VA (50Hz), 1VA (60Hz) DC: 0.8W
Power Consumption DPDT AC: 1.4VA (50Hz), 1.2VA (60Hz) DC: 0.9W
(approx.) 3PDT AC: 2VA (50Hz), 1.7VA (60Hz) DC: 1.5W
4PDT AC: 2.5VA (50Hz), 2VA (60Hz) DC: 1.5W
Insulation Resistance 100M minimum (500V DC megger)
Relays & Sockets

Between live and dead parts: 2,000V AC, 1 minute


SPDT Between contact and coil: 2,000V AC, 1 minute
Between contacts of the same pole: 1,000V AC, 1 minute
Dielectric Strength 3
Between live and dead parts: 2,000V AC, 1 minute
DPDT
Between contact and coil: 2,000V AC, 1 minute
3PDT
Between contacts of different poles: 2,000V AC, 1 minute
4PDT
Between contacts of the same pole: 1,000V AC, 1 minute
Electrical: 1,800 operations/hour maximum
Operating Frequency
Mechanical: 18,000 operations/hour maximum
Damage limits: 10 to 55Hz, amplitude 0.5 mm
Vibration Resistance
Operating extremes: 10 to 55Hz, amplitude 0.5 mm
Timers

Damage limits: 1,000m/s2 (100G)


Shock Resistance Operating extremes: 200m/s2 (20G - SPDT, DPDT)
100m/s2 (10G - 3PDT, 4PDT)
Mechanical Life 50,000,000 operations minimum
DPDT 500,000 operations minimum (120V AC, 10A)

Electrical Life SPDT


3PDT 200,000 operations minimum (120V AC, 10A)
4PDT
Contactors

SPDT
Operating DPDT
25 to +70C (no freezing)
Temperature 4 3PDT
4PDT
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) SPDT: 24g, DPDT: 37g, 3PDT: 50g, 4PDT: 74g

Note: Above values are initial values.


1. Measured using 5V DC, 1A voltage drop method
Terminal Blocks

2. Measured at the rated voltage (at 20C), excluding contact bouncing


Release time of relays with diode: 40 ms maximum
3. Relays with indicator or diode: 1000V AC, 1 minute
4. For use under different temperature conditions, refer to Continuous Load Current vs. Operating Temperature Curve. The operating
temperature range of relays with indicator or diode is 25 to +40C.
Circuit Breakers

776 www.IDEC.com
Relays & Sockets RH

Characteristics (Reference Data)

Switches & Pilot Lights


Electrical Life Curves
AC Load DC Load
1000 1000

(RH1) 120V AC resistive (RH1)


500 500
Life ( 10,000 operations)

Life ( 10,000 operations)


30V DC resistive
100 100

Signaling Lights
50 50
100V DC resistive

30V DC inductive
20 20
240V AC inductive 240V AC resistive
120V AC inductive 100V DC inductive

10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)

(RH2) 1000 (RH2) 1000


120V AC resistive

Relays & Sockets


30V DC resistive
500 500
Life ( 10,000 operations)

Life ( 10,000 operations)


100 100

50 50 100V DC resistive 30V DC


inductive
240V AC inductive 240V AC resistive
120V AC inductive 100V DC inductive

20 20

Timers
10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)

(RH3/RH4) 1000 (RH3/RH4) 1000

120V AC resistive
30V DC resistive
500 500
Life ( 10,000 operations)

Life ( 10,000 operations)

30V DC inductive

Contactors
100 100

50 50

20 240V AC inductive 20 100V DC resistive


240V AC resistive 100V DC inductive
120V AC inductive
10 10
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A)

Maximum Switching Capacity


Terminal Blocks
(RH1) (RH2/RH3/RH4)
10.0 10.0
AC resistive AC resistive

5.0 5.0 AC inductive


AC inductive

DC resistive
Load Current (A)

Load Current (A)

DC resistive
1.0 1.0
DC inductive
Circuit Breakers

0.5 DC inductive 0.5

0.1 0.1
1 5 10 50 100 200 300 1 5 10 50 100 200 300
Load Voltage (V) Load Voltage (V)

800-262-IDEC (4332) USA & Canada 777


RH Relays & Sockets

Continuous Load Current vs. Operating Temperature Curve (Basic Type, With Check Button, and Top Bracket Mounting Type)
Switches & Pilot Lights

(RH1) Note: The rated voltage is (RH2) Note: The rated voltage is (RH3/RH4) Note: The rated voltage is
applied to the coil. applied to the coil. applied to the coil.
100 100 100

90 90 90
Operating Temperature (C)

Operating Temperature (C)


80 80

Operating Temperature (C)


80
DC Coil
70 70 DC Coil 70

60 60 60

50 AC Coil 50 50 AC/DC Coil


40 AC Coil 40
40
30 30 30

20 20 20
Signaling Lights

10 10 10

0 0 0
1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10
Load Current (A) Load Current (A) Load Current (A)

Internal Connection (View from Bottom)


Basic Type
SPDT DPDT 3PDT 4PDT With Check Button
Relays & Sockets

Front
1 2 3 4 Pushbutton
5 6 7 8
9 10 11 12
Contacts can be operated by pressing the
13 () (+) 14 check button.

With Indicator (-L type)


SPDT 3PDT 4PDT DPDT

1 1 2 4 1 2 3 4 1 4
5 5 6 8 5 6 7 8 5 8
Below Below When the relay is energized,
Timers

9 9 10 12 9 10 11 12 9 12
100V 13 14 24V AC/ the indicator goes on.
() (+) 13 ( ) ( + )14 ( + )14
13( ) ( + )14 13( ) Relay coils less than 100V
AC/DC DC
DC do not contain a protec-
tion diode (except DPDT).
Relay coils below 100V
use LED indicator, coils
1 1 4
1 2 4 1 2 3 4 above 100V use neon lamp
5 5 8
100V 5 6 8 5 6 7 8 24V AC/ indicator.
9 9 12
AC/DC 9 10 12 9 10 11 12 DC and LED color of DPDT model
13 14 13 () (+) 14
and over over is green
Contactors

() (+) 13 () (+) 14

13( ) ( + )14

With Diode (-D type)


SPDT DPDT 3PDT 4PDT
Contains a diode to absorb the back emf
1 1 4 1 2 4 1 2 3 4 generated when the coil is de-energized. The
5 5 8 release time is slightly longer. Available for DC
Terminal Blocks

5 6 8 5 6 7 8
9 9 12 9 10 12 9 10 11 12 coil only.
13
()
14
(+)
13 () (+) 14
13 () (+) 14 13 () (+) 14 Diode Characteristics
Reverse withstand voltage: 1,000V
Forward current: 1A
Circuit Breakers

778 www.IDEC.com
Relays & Sockets RH

With Indicator LED & Diode (-LD type)

Switches & Pilot Lights


SPDT 3PDT 4PDT DPDT

1
1 4
5
5 8
9 Below
Below 9 12
13 14 24V AC/
100V DC () (+) 13( ) ( + )14
DC
Contains an LED indicator and
a surge absorber, and has the
same height as the basic type.

Signaling Lights
1
1 4
LED color of DPDT model is
5
5 8 green.
9 24V AC/
100V DC 9 12
13 ( ) 14( + ) DC and
and over
over
13 14
() (+)

Dimensions (mm)

Relays & Sockets


RH1B-U/RH1B-UL/RH1B-UD/RH1B-ULD RH2B-U/RH2B-UL/RH2B-UD/RH2B-ULD RH3B-U/RH3B-UL/RH3B-UD/RH3B-ULD
Total length from panel surface including relay socket Total length from panel surface including relay socket Total length from panel surface including relay socket
SH1B-05: 61.5 (63.5) max., SH1B-51: 39.6 (41.6) max. SH2B-05: 61.5 (63.5) max., SH2B-51: 39.6 (41.6) max. SH3B-05: 61.5 (63.5) max., SH3B-51: 39.6 (41.6) max.
Dimensions in the ( ) Dimensions in the ( ) Dimensions in the ( )
include a hold-down spring. include a hold-down spring. include a hold-down spring.
4.7

2.6 hole
4.7

2.6 hole

1 2.6 hole

4.7
5 1 4
27.5

9 5 8
0.5

27.5
0.5

9 12
13 14
13 14 1 2 4
5 6 8

Timers
27.5
5.4 14

0.5
9 10 11

35.6 max. 6.4 35.6 max. 6.4 21 13 14

35.6 max. 6.4 31

RH4B-U/RH4B-UL/RH4B-UD/RH4B-ULD RH1B-UT RH2B-UT


Total length from panel surface including relay socket
4.7

SH4B-05: 61.5 (63.5) max., SH4B-51: 39.6 (41.6) max.

10
Dimensions in the ( )

Contactors
include a hold-down spring. 2.6 hole
0.5
4.7

2.6 hole

4.7
0.5
4.7

1
5
1 4
5.9
43.2

27.5

9
38

5 8

5.9
43.2

27.5
38

13 14
9 12

13 14

2.6 hole
6.6

7.25

3.5 2 5.4
4.7

14.5 35.6 max. 6.4 3.5 2

1 2 3 4 21.5 35.6 max. 6.4


5 6 7 8
27.5
0.5

9 10 11 12

13 14

Terminal Blocks
35.6 max. 6.4 41

RH3B-UT RH4B-UT
10

10
4.7
10

10
10

3.5
Circuit Breakers

2.6 hole
4.7

2 3.5
0.5
4.7

2.6 hole
0.5
4.7

1 2 4
1 2 3 4
5.9

5 6 8
43.2
38

28

5.9

5 6 7 8
9 10 12
28
38
44

13 14 9 10 11 12
13 14
7.25
7.25

21.5 2 35.6 max. 6.4 28


31.5 35.6 max. 6.4 42 max. 41.5

800-262-IDEC (4332) USA & Canada 779


RH Relays & Sockets

Dimensions cont (mm)


Switches & Pilot Lights

RH1V2-U/RH1V2-UD RH2V2-U/RH2V2-UL/RH2V2-UD
8-2.4 holes
0.5

4.7
3-2.4 holes
2-2 holes

7.25
0.5
1.5

4.7
0.5

2
7.15

0.5
1

13.15
5

7.8
1 4

27.5
9

12.5
0.5

5 8

27.5
6.6
13 14
9 12
13 14

5
35.6 max. 4.6 14 10

2
Signaling Lights

35.6 max. 4.6 21


4.4 14.2

RH3V2-U/RH3V2-UL/RH3V2-D RH4V2-U/RH4V2-UL/RH4V2-UD
30
11-2.4 holes 10 10

4.7
14-2.4 holes 10

4.7
2

13.15
1 2 4

13.15
7.8

5 6 8

7.8
1 2 3 4
27.5
Relays & Sockets

9 10 11 5 6 7 8
0.5

27.5
9 10 11 12

0.5
13 14
13 14
7.25

7.25
0.5 31
0.5 41
35.6 max. 4.6
35.6 max. 4.6

Standard DIN Rail Mount Sockets


SH1B-05 SH2B-05
17 31.5 22 31.5
8 18 DIN Rail Terminal Arrangement DIN Rail
M3.5 Terminal 8 M3.5 Terminal 18
Screw
(BNDN) (BNDN) Terminal Arrangement
2-4.2 Mounting Holes Screw
5 2-4.2 Mounting Holes
(or M4 Tapped Holes) 8 5
Timers

1 (or M4 Tapped Holes)


4.2

4 1
4.2

16
67

47

26
67

47

M3 Terminal 5.5 min. 4.8 min. 14 13 4.4 max. 5.5 min. 14 13


Screw 9 12 9
4.4 max. 4 max.
(Top View) (Top View)
16 14.5 26 14.5 7.9 max.
3.6 min. 3.2 min.
2.5

20 25 30 25 3.6 min.
2.5

7.9 max. 5.9 max.

(For terminals 1, 5, and 9) (For terminals 13 and 14)


Contactors

SH3B-05 SH4B-05
32
31.5 42 31.5

8 18 DIN Rail 8 18 DIN Rail


M3.5 Terminal Terminal Arrangement M3.5 Terminal
(BNDN) Terminal Arrangement
(BNDN) Screw
Screw 2-4.2 Mounting Holes
2-4.2 Mounting Holes 8 7 6 5
8 6 5 (or M4 Tapped Holes)
4.2

(or M4 Tapped Holes) 4 3 2 1


4.2

4 2 1

46
67

47
67

47

36
4.4 max. 5.5 min. 14 13
4.4 max. 5.5 min. 14 13
Terminal Blocks

12 11 10 9
12 10 9
(Top View)
(Top View) 46 14.5
36 14.5 7.9 max.
7.9 max. 50 25 3.6 min.
2.5
2.5

40 25 3.6 min.
Circuit Breakers

780 www.IDEC.com
Relays & Sockets RH

Dimensions cont (mm)

Switches & Pilot Lights


Finger-safe DIN Rail Mount Sockets
SH1B-05C SH2B-05C
22 36
17 36 M3.5 Terminal
M3.5 Terminal 7 25 DIN Rail
7 25 Screw (BNDN) Terminal Arrangement
Screw DIN Rail Terminal Arrangement
(BNDN)
5 2-4.2 Mounting Holes 8 5
5 5
(or M4 Tapped Holes) 4 1
2-4.2 Mounting Holes

4.2
1
(or M4 Tapped Holes)
4.2

49
69
26
48
69

16
14 13
M3 Terminal

Signaling Lights
14 13 12 9
Screw
9
Ring terminals 18.7 Ring terminals (Top View)
26
16 18.7
cannot be used. (Top View) cannot be used.

1.7
30 29.5
20 29.5
1.7


SH3B-05C SH4B-05C
32 When using
M3.5 Terminal 36 42 BAA/BAP: 33
7 Screw DIN Rail
25 Terminal Arrangement 7 25
(BNDN)
DIN Rail
8 6 5 (BAA/BAP) Terminal Arrangement
5 2-4.2 Mounting Holes
4 2 1
(or M4 Tapped Holes)

Relays & Sockets


5 2-4.2 Mounting Holes 8 7 6 5
4.2

(or M4 Tapped Holes) 4 3 2 1

4.2
49
69

36

49
69
14 13 46
12 10 9
14 13

Ring terminals (Top View) 12 11 10 9

36 18.7
cannot be used. Ring type crimping (Top View)
1.7

40 29.5 46 18.7 terminals cannot be used.


1.7

50 29.5

Through Panel Mount Socket


SH1B-51 SH2B-51

Timers
Contactors

SH3B-51 SH4B-51

Terminal Blocks


Circuit Breakers

800-262-IDEC (4332) USA & Canada 781


RH Relays & Sockets

Dimensions cont (mm)


Switches & Pilot Lights

PCB Mount Sockets


SH1B-62 SH2B-62
Terminal Arrangement 3-2.4 holes 6.8 18 min. Terminal Arrangement 2.85 21.5 min.
1 4 15.5

6.95
1 4.4

5.65
5 5 8 10

25.4
4.7
25.4

29

4.7
9 12
31

9
13 14 13 14

11.85

0.3
21.2 3 (Bottom View)
0.3

18

12.5
3 (Bottom View)
11

5.95
11

31 min.*

6.6
2-2 holes

29 min.*
15 8-2.4 holes
15
Signaling Lights

2
1.5 (Tolerance 0.1) 2
* 36 min. when using * 34 min. when using (Tolerance 0.1)
12.2 hold-down springs hold-down springs

SH3B-62 SH4B-62
Terminal Arrangement 36 min. Terminal Arrangement 6.85 45 min.
7.35 21.3 1 2 3 4 31.3
1 2 4

6.65
5 6 8 10 10 5 6 7 8 10 10 10

25.4

4.7
31
25.4

4.7

9 10 11 12
31

9 10 12
13 14
13 14

0.3
45 3 (Bottom View)
0.3
Relays & Sockets

36 3 (Bottom View)
6.65
12.5

12.5
11
11
15
6.6

6.6
31 min.*
31 min.*

15 14-2.4 holes
11-2.4 holes
2
2 39.2 * 36 min. when using
hold-down springs (Tolerance 0.1)
30.2 * 36 min. when using (Tolerance 0.1)
hold-down springs
Timers
Contactors
Terminal Blocks
Circuit Breakers

782 www.IDEC.com
Relays & Sockets RR

RR Series Power Relays

Switches & Pilot Lights


Key features:
SPDT through 3PDT, 10A contacts
Midget power type relays
Available in pin and blade terminal styles.
Options include an indicator, check button for test operations and side flange.
DIN rail, surface and panel mount sockets are available for a wide a variety of
mounting applications.

Signaling Lights
Part Number Selection
Part Number
Coil Voltage Code
Contact Model Pin Terminal Blade Terminal*
(Standard Stock Items in Bold)
SPDT Standard RR1BA-U 0

Relays & Sockets


With Indicator RR1BA-UL 0
With Check Button RR1BA-UC 0
With Indicator and Check Button RR1BA-ULC 0
Side Flange Model RR1BA-US 0
DPDT Standard RR2P-U 0 RR2BA-U 0
With Indicator RR2P-UL 0 RR2BA-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,
With Check Button RR2P-UC 0 RR2BA-UC 0 AC240V,
With Indicator and Check Button DC6V, DC12V, DC24V, DC48V, DC110V
RR2P-ULC 0 RR2BA-ULC 0

Timers
Side Flange Model RR2BA-US 0

3PDT Standard RR3PA-U 0 RR3B-U 0


With Indicator RR3PA-UL 0 RR3B-UL 0
With Check Button RR3PA-UC 0 RR3B-UC 0
With Indicator and Check Button RR3PA-ULC 0 RR3B-ULC 0

Side Flange Model RR3B-US 0

Contactors
*Blade type not TUV tested or CE marked.
Side flange model mounts directly to panel with no socket required. Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RR3B-U AC120V
Part No. Coil Voltage Code
Sockets
Relays Standard DIN Rail Mount Finger-safe DIN Rail Mount Through Panel Mount

Terminal Blocks
SR2P-05
RR2P SR2P-05C SR2P-51
SR2P-06

SR3P-05
RR3PA SR3P-05C SR3P-51
SR3P-06
RR1BA
RR2BA SR3B-05 SR3B-51
RR3B
Circuit Breakers

All DIN rail mount sockets shown above can be


mounted using DIN rail BNDN1000.

800-262-IDEC (4332) USA & Canada 783


RR Relays & Sockets

Hold Down Springs & Clips


Switches & Pilot Lights

For DIN For Through Panel &


Appearance Description Relay
Mount Socket PCB Mount Socket
RR2P SR2B-02F1
SR3P-01F1
Pullover Wire RR3PA SR3B-02F1
Spring
RR1BA, RR2BA,
SR3B-02F1 SR3B-02F1
RR3B

Leaf Spring
RR2P, RR3PA SFA-203
(side latch)
Signaling Lights

Accessories
Item Appearance Use with Part No. Remarks
The BNDN1000 is designed to accommodate DIN mount sockets.
Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).
Relays & Sockets

DIN Rail End


DIN rail BNL5 9.1 mm wide.
Stop

Horseshoe clip for sockets


Y778-011
Replacement SR3B-05, SR2P-06, SR3P-06
For use on DIN rail mount socket when using pullover wire hold down
Hold-Down
spring. 2 pieces included with each socket.
Spring Anchor Chair clip for sockets
Y703-102
SR2P-05(C), SR3P-05(C)
Timers
Contactors
Terminal Blocks
Circuit Breakers

784 www.IDEC.com
Relays & Sockets RR

Specifications

Switches & Pilot Lights


Contact Material Silver
Contact Resistance 1 30 m maximum
Minimum Applicable Load 1V DC, 10 mA
Operating Time 2
25 ms maximum
Release Time 2
25 ms maximum
AC: 3 VA (50 Hz), 2.5 VA (60 Hz)
Power Consumption (approx.)
DC: 1.5W
Insulation Resistance 100 M minimum (500V DC megger)

Signaling Lights
Between live and dead parts: 1500V AC, 1 minute
Between contact and coil: 1500V AC, 1 minute
Pin Terminal
Between contacts of different poles: 1500V AC, 1 minute
Dielectric Between contacts of the same pole: 1000V AC, 1 minute
Strength Between live and dead parts: 2000V AC, 1 minute 1. Measured using 5V DC, 1A voltage drop method
2. Measured at the rated voltage (at 20C), excluding contact
Between contact and coil: 2000V AC, 1 minute bouncing
Blade Terminal 3. For use under different temperature conditions, refer to
Between contacts of different poles: 2000V AC, 1 minute
Continuous Load Current vs. Operating Temperature Curve.

Relays & Sockets


Between contacts of the same pole: 1000V AC, 1 minute
Electrical: 1800 operations/h maximum
Operating Frequency
Mechanical: 18,000 operations/h maximum
Damage limits: 10 to 55 Hz, amplitude 0.5 mm
Vibration Resistance
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Damage limits: 1000 m/s2 (100g)
Shock Resistance
Operating extremes: 100 m/s2 (10G)
Mechanical Life 10,000,000 operations
Electrical Life 200,000 operations (220V AC, 5A)

Timers
Operating Temperature 3
25 to +40C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)
Weight (approx.) (Standard type) RR2P: 90g, RR3PA: 96g, RR1BA/RR2BA/RR3B: 82g

Coil Ratings
Rated Current (mA) 15% (at 20C) Operating Characteristics (values at 20C)
Coil Resistance ()
Rated Voltage (V) Maximum Continuous
50 Hz 60 Hz 10% (at 20C) Pickup Voltage Dropout Voltage

Contactors
Applied Voltage
6 490 420 4.9
12 245 210 18
AC 24 121 105 79
110% 80% maximum 30% minimum
(50/60 Hz) 110 27 23 1,680
120 24 20.5 2,100
240 12.1 10.5 8,330

Terminal Blocks
6 240 25
12 120 100
DC 24 60 400 110% 80% maximum 10% minimum
48 30 1,600
110 13 8,460
Circuit Breakers

800-262-IDEC (4332) USA & Canada 785


RR Relays & Sockets

Contact Ratings UL Ratings


Switches & Pilot Lights

Maximum Contact Capacity Voltage Resistive General use Horse Power Rating
Allowable Contact Power Rated Load 240V AC 10A 7A 1/3 HP
Continuous
Current Resistive Inductive 120V AC 10A 7.5A 1/4 HP
Voltage (V) Res. Load Ind. Load
Load Load 30V DC 10A 7A
110 AC 10A 7.5A
1650VA AC 1100VA AC CSA Ratings
10A 220 AC 7.5A 5A
300W DC 150W DC
30 DC 10A 5A Voltage Resistive General use
240V AC 10A 7A
Note: Inductive load for the rated load cos = 0.3, L/R = 7 ms
Signaling Lights

120V AC 10A 7.5A


100V DC 0.5A
TV Ratings 30V DC 10A 7.5A
Voltage
240V AC 10A
AC: cos = 1.0, DC: L/R = 0 ms
30V DC 10A
Relays & Sockets

Socket Specifications
Relays Terminal Electrical Rating Wire Size Torque
SR2P-05 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
SR2P-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
SR2P-06 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
DIN Rail
SR3P-05 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
Sockets
SR3P-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
SR3P-06 M3 screw with captive wire clamp 300V, 10A Maximum 2 - #12 AWG 9 - 11.5inlbs
Timers

SR3B-05 M3 screw with captive wire clamp 300V, 15A (10A)* (*CSA rating) Maximum 2 - #12 AWG 9 - 11.5inlbs
SR2P-51 Solder 300V, 10A
Through
Panel Mount SR3P-51 Solder 300V, 10A
Sockets
SR3B-51 Solder 300V, 10A
Contactors
Terminal Blocks
Circuit Breakers

786 www.IDEC.com
Relays & Sockets RR

Characteristics (Reference Data)

Switches & Pilot Lights


Electrical Life Curves
AC Load DC Load
1000 1000

500 500
30V DC

Life ( 10,000 operations)


resistive
Life ( 10,000 operations)

100 100
110V AC resistive
100V DC resistive
50 50

Signaling Lights
220V AC resistive
110V AC inductive 100V DC inductive
20 20
220V AC inductive
30V DC inductive
10 10
0.1 0.5 1 5 10 0.01 0.05 0.1 0.5 1 5 10
Load Current (A) Load Current (A)

Continuous Load Current vs. Operating Temperature Curve


Maximum Switching Capacity (Standard Type, With Check Button, and Side Flange Type)
10.0
AC
resistive 100

Relays & Sockets


5.0 90
AC
inductive 80

Operating Temperature (C)


DC resistive
70
Load Current (A)

DC Coil
60
1.0
DC inductive 50
AC Coil
0.5 40
30
20
10
1 5 10 30 50 100 200 300 0
1 2 3 4 5 6 7 8 9 10
Load Voltage (V) Load Current (A)

Timers
Internal Connection (View from Bottom)
Standard Type
RR2P-U RR3PA-U RR1BA-U RR2BA-U RR3B-U With Check Button

Front
Pushbutton

Contacts can be operated by pressing the

Contactors
check button.

With Indicator (-UL type)


RR2P RR3PA RR1BA RR2BA RR3B

Terminal Blocks
Coil
Below
100V When the relay is energized,
AC/DC the indicator goes on.
An LED protection diode is
not contained in relay coils
below 100V DC.
Coils below 100V use
LED indicator while coils
above 100V use neon lamp
Coil
Circuit Breakers

indicator.
100V
AC/DC
and over

800-262-IDEC (4332) USA & Canada 787


RR Relays & Sockets

Dimensions (mm)
Switches & Pilot Lights

RR2P-U/RR2P-UL RR3PA-U/RR3PA-UL
Total length from panel surface including relay socket Total length from panel surface including relay socket
SR2P-05: 84.5 (87.5) max., SR2P-511: 63 (68) max. SR3P-05: 84.5 (87.5) max., SR3P-511: 63 (68) max.

6
5 7

4 5 4 8
3 6

35.6
35.6
2 7 3 9
1 8
2 10
1 11

9.9 9.9
28.6 35.6
Signaling Lights

55.5 max. 13 55.5 max. 13


Dimensions in the ( ) Dimensions in the ( )
include a hold-down spring. include a hold-down spring.

RR1BA-U/RR2BA-UL/RR2BA-U
RR2BA-UL/RR3B-U/RR3B-UL RR1BA-US/RR2BA-US/RR3B-US
63.5

7.3 3.0 2.0 oblong hole


4.7

2-4.5 Mounting Holes

11.1
Relays & Sockets

16.0
4.2

11.1
3.0 2.0 oblong hole
63.5

Total length from panel surface including relay socket


SR3B-05: 73 (76) max., SR3B-51: 56 (60) max.

4.7
47.5 max. 16.1
73.5
0.5

1 2 3
4 5 6

7 8 9
36

0.5
1 2 3
4 5 6
A B
7 8 9

36
36 A B
47.5 max. 7.3
Dimensions in the ( ) 36
include a hold-down spring.
Timers

Standard DIN Rail Mount Sockets


SR2P-05 SR2P-06
36 DIN Rail 40
8 M3.5 Terminal 35 8 DIN Rail
(BNDN) Terminal Arrangement 25.5
Screw (BNDN) Terminal Arrangement
2-4.2 Mounting Holes 5 4 M3.5 Terminal
2-4.2 Mounting Holes 6 5 4 3
(or M4 Tapped Holes) 6 3 Screw
(or M4 Tapped Holes)
Contactors

25
52

33

25
60

29 7 2
33
8 1
4.4 max. 5 min.
4.2 hole (Top View) 4.9 max. 5 min. 7 8 1 2
16.5 4.2 hole
33 (Top View)
18
3

29 20
7.9 max.
28.5 22 7.9 max.
1

3.6 min.
3.6 min.

SR3P-05 SR3P-06
42 59
Terminal Blocks

DIN Rail DIN Rail


8 M3.5 Terminal 35 8 M3.5 Terminal 28.5
(BNDN) (BNDN)
Screw Terminal Arrangement Screw Terminal Arrangement
2-4.2 Mounting Hole 7 6 5
2-4.2 Mounting Holes 8 7 6 5 4
(or M4 Tapped Holes) 8 4 (or M4 Tapped Holes)
27
52

33

27
60

34 9 3 33
10 11 1 2
4.4 max. 5 min. 4.2 hole
4.2 hole (Top View) 4.9 max. 5 min.
9 10 11 1 2 3
34 16.5
18 (Top View)
20 33
7.9 max.
3

28.5 22 7.9 max.


1

3.6 min.
3.6 min.
Circuit Breakers

788 www.IDEC.com
Relays & Sockets RR

Switches & Pilot Lights


Standard DIN Rail Mount Sockets
SR3B-05
36
8
31.5 DIN Rail Terminal Arrangement
M3.5 Terminal (BNDN)
Screw 6 5 4
2-4.2 Mounting Holes 3 2 1
(or M4 Tapped Holes)
4.2

37
76

56

B A
4.4 max. 5.5 min. 9 8 7

(Top View)

Signaling Lights
7.9 max.
37 14.5 3.6 min.
43 25
2

Finger-safe DIN Rail Mount Sockets


SR2P-05C SR3P-05C
36 42
36.5 DIN Rail 36.5
7 7 DIN Rail
(BNDN)
Terminal Arrangement (BNDN)
2-4.2 Mounting Holes Terminal Arrangement
5 (or M4 Tapped Holes) 5 4

Relays & Sockets



7 6 5
6 3 2-4.2 Mounting Holes
(or M4 Tapped Holes) 8 4

29
58

4.2 hole

58
7 2
4.2 hole 34 9 3
8 1
10 11 1 2
(Top View)
Ring type crimping (Top View)
21.5 terminals cannot be used.
29
2.2

30 34 21.5 Ring type crimping



2.2

30 terminals cannot be used.

Through Panel Mount Socket


SR2P-51 SR3P-51

Timers
Surfarface

Surfarface
2-3.5 Mounting Holes 2-3.5 Mounting Holes
4.2 4.2 (or M3 Tapped Holes)
(or M3 Tapped Holes)
Panel

Panel

Terminal Arrangement
6
6

Terminal Arrangement

4 5 5 6 7
3 6 4 8

0
0

29
29

38

38
50
38

38
50

3
3

3 9
2 7
2 10
1 8 1 11

(Bottom View) (Bottom View)


34 2.5 10 11 34 2.5 10 11
2.5
2.5

Contactors
SR3B-51
35.5* 2-4.2 Mounting Holes
38 7.5 11 max. Terminal Arrangement (M4 Tapped Holes)
6.75 22
11.5 min.

1 2 3
0.3

4 5 6
32.5
51.5

32
35
43

43

7 8 9
A B

22 3 6.5
(Bottom View)
(Tolerance 0.3)

Terminal Blocks
3.5 *When two or more sockets are
35 mounted side by side:
L = 38 (N 1) + 35.5
N: No. of sockets mounted Circuit Breakers

800-262-IDEC (4332) USA & Canada 789


RU Relays & Sockets

RU Series Universal Relays


Switches & Pilot Lights

Key features:
Full featured universal miniature relays
Designed with environment taken into consideration
Two terminal styles: plug-in and PCB mount
Non-polarized LED indicator
No internal wires, lead-free construction
Cadmium-free contacts
Mechanical flag indicator
Signaling Lights

Manual latching lever with color coding for AC or DC coil


Snap-on yellow marking plate; optional marking plates are available in four other colors
Maximum contact ratings: 10A (RU2), 6A (RU4), 3A (RU42)
UL Recognized, CSA Certified, EN Compliant

EN61810-1
Relays & Sockets


With Latching or Momentary Lever
Latching and Momentary Lever
Using the lever, operation can be checked without energiz-
Mechanical Indicator*
ing the coil. The lever is color coded for AC and DC coils.
The contact position can be confirmed through
the five small windows. Latching Momentary
AC coil: Orange Red
Marking Plate
Standard yellow marking plate is easily replaced DC coil: Green Blue
with optional marking plates in four colors for
easy identification of relays.
Timers

In Normal Operation
LED Indicator*
Non-polarized green LED indicator is standard
provision for plug-in terminal, latching lever
types

Note: Turn off the power to the relay coil when using the latching
Contactors

lever. After checking the operation, return the latching lever


in the normal position.

Standard (without lever)

AC/DC Color Marking


For identification of AC or DC coils.
AC coil: Yellow
DC coil: Blue
Terminal Blocks

Coil Voltage Tape Color


Mechanical Indicator*
24V AC White
Marking Plate 100 to 110V AC Clear

LED Indicator* 110 to 120V AC Blue


Non-polarized green LED indicator is standard 200 to 220V AC Black
provision for plug-in terminal types.
220 to 240V AC Red
24V DC Green
Circuit Breakers

6V DC
AC Coil DC Coil
12V DC Voltage marking on
48V DC yellow tape
*Not available on PCB type.
110V DC

790 www.IDEC.com
Relays & Sockets RU

Part Number Selection

Switches & Pilot Lights


Part Number
Coil Voltage Code
Contact Model Standard With Latching Lever With Momentary Lever
(Standard Stock in bold)

DPDT (10A) A24, A110, A220


Standard RU2S-C-0 RU2S-0 RU2S-M-0
D6, D12, D24, D48, D110
With RC (AC coil only) RU2S-CR-0 RU2S-R-0 RU2S-MR-0 A110, A220
With diode (DC coil only) RU2S-CD-0 RU2S-D-0 RU2S-MD-0 D6, D12, D24, D48, D110

Signaling Lights
A24, A110, A220
PCB RU2V-NF-0
D6, D12, D24, D48, D110
4PDT (6A) A24, A110, A220
Standard RU4S-C-0 RU4S-0 RU4S-M-0
D6, D12, D24, D48, D110
With RC (AC coil only) RU4S-CR-0 RU4S-R-0 RU4S-MR-0 A110, A220
With diode (DC coil only) RU4S-CD-0 RU4S-D-0 RU4S-MD-0 D6, D12, D24, D48, D110
A24, A110, A220
PCB RU4V-NF-0
D6, D12, D24, D48, D110

Relays & Sockets


4PDT Bifurcated (3A) A24, A110, A220
Standard RU42S-C-0 RU42S-0 RU42S-M-0
D6, D12, D24, D48, D110
With RC (AC coil only) RU42S-CR-0 RU42S-R-0 RU42S-MR-0 A110, A220
With diode (DC coil only) RU42S-CD-0 RU42S-D-0 RU42S-MD-0 D6, D12, D24, D48, D110
A24, A110, A220
PCB RU42V-NF-0
D6, D12, D24, D48, D110

1. Plug-in terminal models have an LED indicator and a mechanical indicator as standard.
2. PCB models do not have an LED indicator or a mechanical indicator. Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RU2S-C A110

Timers
Part No. Coil Voltage Code

Coil Voltage Table


Coil Voltage Code A24 A110 A220 D6 D12 D24 D48 D110
Coil Rating 24V AC 110-120V AC 220-240V AC 6V DC 12V DC 24V DC 48V DC 110V DC

Sockets
Spring Clamp Standard DIN Finger-safe DIN

Contactors
Relays Panel Mount PCB Mount
DIN Rail Mount Rail Mount Rail Mount
SM2S-61
RU2S (DPDT) SU2S-11L SM2S-05 SM2S-05C
SM2S-62
SY4S-51
RU4S (4PDT) SY4S-61
SU4S-11L SY4S-05 SY4S-05C
RU42S (4PDT) SY4S-62

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 791


RU Relays & Sockets

Hold Down Springs & Clips


Switches & Pilot Lights

For Through
For DIN
Appearance Item Relay Panel & PCB
Mount Socket
Mount Socket

Pullover Wire RU2S/RU4S/


SY4S-02F1 SY4S-51F1
Spring RU42S

Leaf Spring RU2S/RU4S/


SFA-202* SFA-302*
Signaling Lights

(side latch) RU42S

Leaf Spring RU2S/RU4S/


SFA-101* SFA-301* Note: Order 2 pieces for each relay
(top latch) RU42S

Accessories
Name Part Number Color Code *
Relays & Sockets

Marking Plate RU9Z-P* A (orange), G (green), S (blue), W (white), Y (yellow)

Specify a color code when ordering. The marking plate can be removed from the relay by inserting
a flat screwdriver under the marking plate.

Specifications
Model (Contact) RU2 (DPDT) RU4 (4PDT) RU42 (4PDT-bifurcated)
Contact Material Silver alloy Silver (gold clad) Silver-nickel (gold clad)
Contact Resistance 1
50 m maximum
Timers

Minimum 24V DC, 5 mA


1V DC, 1 mA 1V DC, 0.1 mA
Applicable Load 2 (reference value)
Operating Time 3 20 ms maximum
Release Time 3 20 ms maximum
Power Consumption AC: 1.1 to 1.4VA (50 Hz), 0.9 to 1.2VA (60 Hz) DC: 0.9 to 1.0W
Insulation Resistance 100M minimum (500V DC megger)
Between contact and coil: 2500V AC, 1 minute
Contactors

Between contacts of different poles:


Dielectric Strength
2500V AC, 1 minute 2000V AC, 1 minute
Between contacts of the same pole: 1000V AC, 1 minute
Electrical: 1800 operations/h maximum
Operating Frequency
Mechanical: 18,000 operations/h maximum
Damage limits: 10 to 55 Hz, amplitude 0.5 mm
Vibration Resistance
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Damage limits: 1000 m/s2 (100G)
Terminal Blocks

Shock Resistance
Operating extremes: 150 m/s2 (15G)
AC: 50,000,000 operations
Mechanical Life 50,000,000 operations
DC: 100,000,000 operations
Electrical Life 4 See table on page 794
Operating PCB model: 55 to +70C (no freezing)
Temperature 5 Blade model: 55 to +60C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)
Weight Approx. 35g
Circuit Breakers

1. Measured using 5V DC, 1A voltage drop method 4. Contact Load and Electrical Life (at ambient temperature 20C)
2. Measured at operating frequency of 120 operations/min (failure rate level P, reference value) 5. Measured at the rated voltage.
3. Measured at the rated voltage (at 20C), excluding contact bouncing;
Release time of AC relays with RC: 25 ms maximum
Release time of DC relays with diode: 40 ms maximum

792 www.IDEC.com
Relays & Sockets RU

Accessories

Switches & Pilot Lights


Item Appearance Use with Part No. Remarks
The BNDN1000 is designed to accommodate DIN mount sockets.
Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).

DIN Rail End


DIN rail BNL5 9.1 mm wide.
Stop

Signaling Lights
Replacement
Horseshoe clip for DIN rail For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
sockets spring. 2 pieces included with each socket.
Spring Anchor

Coil Ratings
Rated Current (mA)
Coil Operating Characteristics (values at 20C)
15% (at 20C) Coil Resistance ()
Rated Voltage (V) Voltage
10% (at 20C) Maximum Continuous
Code

Relays & Sockets


50 Hz 60 Hz Pickup Voltage Dropout Voltage
Applied Voltage
24 A24 49.3 42.5 164
AC
110-120 A110 8.4-10.0 7.1-8.2 4,550 110% 80% maximum 30% minimum
(50/60 Hz)
220-240 A220 4.2-5.0 3.6-4.2 18,230
6 D6 155 40
12 D12 80 160
DC 24 D24 44.7 605 110% 80% maximum 10% minimum
48 D48 18 2,560
110 D110 8.9 12,100

Timers
1. The rated current includes the current of the LED indicator.

Surge Suppressor Ratings UL and c-UL Ratings


Model Ratings Resistive General Use Horse Power Rating
Voltage
RC series circuit RU2 RU4 RU42 RU2 RU4 RU42 RU2 RU4 RU42
AC Coil With RC

Contactors
R: 20 k, C: 0.033 F
250V AC 10A 3A 6A 1/10HP
Diode reverse voltage: 1000V
DC Coil With Diode 30V DC 10A 6A 3A
Diode forward current: 1A

CSA Ratings TV Ratings


Contact Ratings Resistive Resistive Inductive
Maximum Contact Capacity Voltage Voltage
RU42 RU2 RU4 RU42 RU2 RU4 RU42
Continuous Allowable Contact Power Voltage Rated Load 250V AC 3A 250V AC 10A 6A 3A 5A 0.8A 0.8A

Terminal Blocks
Contact
Current Resistive Load Inductive Load (V) Res. Load Ind. Load 30V DC 3A 30V DC 10A 6A 3A 5A 1.5A 1.5A
2500VA AC 1250VA AC 250 AC 10A 5A
DPDT 10A
300W DC 150W DC 30 DC 10A 5A
1500VA AC 600VA AC 250 AC 6A 0.8A
4PDT 6A
180W DC 90W DC 30 DC 6A 1.5A
4PDT 750VA AC 200VA AC 250 AC 3A 0.8A
3A
bifurcated 90W DC 45W DC 30 DC 3A 1.5A
Circuit Breakers

1. On 4PDT relays, the maximum allowable total current of neighboring two poles is 6A. At the rated
load, make sure that the total current of neighboring two poles does not exceed 6A (3A + 3A = 6A).
2. Inductive load for the rated load cos = 0.3, L/R = 7 ms

800-262-IDEC (4332) USA & Canada 793


RU Relays & Sockets

Socket Specifications
Switches & Pilot Lights

Sockets Terminal Electrical Rating Wire Size Torque


SU2S-11L Spring clamp terminals 250V/10A 24-16 AWG
SU4S-11L Spring clamp terminals 250V/6A (using RU4), 10A (using RU2) 24-16 AWG
DIN Rail Mount SM2S-05 M3 screw with captive wire clamp 300V, 10A Maximum up to 2#14AWG 5.5 - 9inlbs
Sockets SM2S-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum up to 2#14AWG 5.5 - 9inlbs
SY4S-05 M3 screw with captive wire clamp 300V, 7A (using RU4), 10A (using RU2) Maximum up to 2#14AWG 5.5 - 9inlbs
SY4S-05C M3 screw with captive wire clamp, fingersafe 300V, 7A (using RU4), 10A (using RU2) Maximum up to 2#14AWG 5.5 - 9inlbs
Through Panel
Signaling Lights

SY4S-51 Solder 300V, 7A


Mount Socket
SY4S-61 PCB mount 300V, 7A
PCB Mount Socket
SY4S-62 PCB mount 250V, 7A
Electrical Life Curves
RU2 (Resistive Load) RU4 (Resistive Load) RU42 (Resistive Load)
250V AC 250V AC 250V AC
30V DC 30V DC 30V DC
110V DC 110V DC
1000 110V DC
1000
Relays & Sockets

( 10,000 operations)

100
( 10,000 operations)

( 10,000 operations)
100 100

10 10 10

1 1 1
0.1 0.5 1 5 10 0.1 0.5 1 3 6 0.02 0.1 0.5 1 3 6
Timers

Load Current (A) Load Current (A) Load Current (A)

RU2 (Inductive Load) RU4 (Inductive Load) RU42 (Inductive Load)


250V AC/30V DC 250V AC 250V AC
110V DC 30V DC 30V DC
110V DC 110V DC
1000
( 10,000 operations)

( 10,000 operations)

( 10,000 operations)

100
100 100
Contactors

10 10 10
AC: cos = 0.3
DC: L/R = 7 ms AC: cos = 0.3 AC: cos = 0.3
DC: L/R = 7 ms DC: L/R = 7 ms

1 1 1
0.1 0.5 1 5 10 0.02 0.1 0.5 0.02 0.1 0.5
Load Current (A) Load Current (A) Load Current (A)

Maximum Switching Current


Terminal Blocks

RU2 RU4 RU42 (Bifurcated)


AC resistive
AC inductive
(cos = 0.3)
10
5

DC resistive
Load Current (A)

1
Circuit Breakers

DC inductive
0.1 L/R = 7 ms

10 30 100 250 500


Load Voltage (V)

794 www.IDEC.com
Relays & Sockets RU

Ambient Temperature vs. Temperature Rise Curves

Switches & Pilot Lights


RU2 (AC Coil, 50 Hz) RU2 (AC Coil, 60 Hz) RU2 (DC Coil)
120 120 120
110 110 110
100 100 100
90 90 90

Temperature Rise (C)


Temperature Rise (C)

Load current

Temperature Rise (C)


80 10A 2 poles 80 80
Load current Load current
70 70 10A 2 poles 70 10A 2 poles
60 60 60
50 50 50

Signaling Lights
40 Load current 40 40
5A 2 poles
30 30 Load current 30 Load current
No load current 5A 2 poles 5A 2 poles
20 20 20 No load current
No load current
10 10 10

0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)

RU4/RU42 (AC Coil, 50 Hz) RU4/RU42 (AC Coil, 60 Hz) RU4/RU42 (DC Coil)
120 120 120

Relays & Sockets


110 110 110
100 100 100
90 90 90
Temperature Rise (C)

Temperature Rise (C)


Temperature Rise (C)

80 80 80
Load current
70 6A 2 poles 70 70
Load current Load current
60 60 6A 2 poles 60 6A 2 poles

50 50 50
40 Load current 40 40
3A 4 poles
30 30 Load current 30 Load current
No load current 3A 4 poles 3A 4 poles
20 20 20 No load current
No load current
10 10 10

Timers
0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70
Ambient Temperature (C) Ambient Temperature (C) Ambient Temperature (C)
The above temperature rise curves show the characteristics when 100% the rated coil voltage is applied.
The heat resistance of the coil is 120C. The slant dashed line indicates the allowable temperature rise for the coil at different ambient temperatures.
Load current 6A x 2 poles is for the RU4 models only.

Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 795


RU Relays & Sockets

Internal Connection (View from Bottom)


Switches & Pilot Lights

RU2S-* Standard RU2S-*R with RC RU2S-*D With Diode RU2V-NF-*


(1)12 (4)42 (1)12 (4)42 (1)12 (4)42 (1)12 (4)42

(5)14 (8)44 (5)14 (8)44 (5)14 (8)44 (5)14 (8)44


(9)11 (12)41 (9)11 (12)41 (9)11 (12)41 (9)11 (12)41

(13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2

24V AC/DC coil or less 24V DC coil or less

(1)12 (4)42 (1)12 (4)42


Signaling Lights

(5)14 (8)44 (5)14 (8)44


(9)11 (12)41 (9)11 (12)41

(13)A1 (14)A2 (13)A1 (14)A2

Over 24V AC/DC coil Over 24V DC coil

RU4S-*/RU42S-* Standard RU4S-*R/RU42S-*R With RC RU4S-*D/RU42S-*D With Diode RU4V-NF-*/RU42V-NF-*


(1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42
Relays & Sockets

(5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44
(9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41

(13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2 (13)A1 (14)A2

24V AC/DC coil or less 24V DC coil or less

(1)12 (2)22 (3)32 (4)42 (1)12 (2)22 (3)32 (4)42

(5)14 (6)24 (7)34 (8)44 (5)14 (6)24 (7)34 (8)44


(9)11 (10)21 (11)31 (12)41 (9)11 (10)21 (11)31 (12)41

(13)A1 (14)A2 (13)A1 (14)A2


Timers

Mechanical Indicator Window


Over 24V AC/DC coil Marking Plate (yellow) Over 24V DC coilMarking Plate (yellow)

Latching LED Indicator Dimensions (mm)


Color Marking
AC: Yellow
Lever (green)
DC: Blue
RU2SAC: Orange
DC: Green
RU2V

Marking Plate Marking Plate


Contactors

Removal Slot Removal Slot


35.0

35.0

0.5

13.2
0.5 0.8
4.0

0.5 2.6 2.6


6.4

1.2 2.2 Hole


12

14
4

21.0
21.0
Terminal Blocks

13
1

27.5
27.5
Mounting Hole Layout
7.0 oles
Marking plate removal slot is provided only on one side. 1H
8-
Insert a flat screwdriver into the slot to remove the marking
plate.
13.2

6.4
4.1 12.7

All dimensions in mm.


Circuit Breakers

796 www.IDEC.com
Mechanical Indicator Window
Marking Plate (yellow) Relays & Sockets Marking Plate (yellow) RU
Color Marking
Latching LED Indicator
Dimensions contAC: Yellow
(mm)

Switches & Pilot Lights


Lever (green) DC: Blue
AC: Orange
RU4S/RU42S
DC: Green
RU4V/RU42V

Marking Plate Marking Plate


Removal Slot Removal Slot

35.0

35.0

0.5
3-4.4
0.5
2.6

4.0
0.5 0.8

Signaling Lights
6.4
2.6
1.2 2.2 Hole

12

14
4

8
21.0

11
3

21.0
10
2

13
1

27.5 27.5

Marking plate removal slot is provided only on one side. Mounting Hole Layout es
Insert a flat screwdriver into the slot to remove the marking 7.0 Hol
1
plate. 14-

Relays & Sockets


13.2
4.4
6.4
4.1 12.7

All dimensions in mm.

Spring Clamp DIN Rail Mount Sockets


SU2S-11L SU4S-11L
31 31

Timers
Terminal Arrangement Terminal Arrangement

12 9 12 11 10 9

8 5 8 7 6 5
2-3.2 2-3.2
24.0 Mounting Holes 4 1 24.0 Mounting Holes 4 3 2 1
80
80

37.5
37.5

28.8
28.8

14 13 14 13

32 Ring terminals 32 Ring terminals


(Top View) (Top View)
4.4
4.4

Contactors
38.3 cannot be used. 38.3 cannot be used.

Standard DIN Rail Mount Sockets


SM2S-05 SY4S-05
31.5 30
30 31.5
0.7

6
DIN Rail
0.7

6 18
DIN Rail M3 Terminal 18 (BNDN)
M3 Terminal Terminal Arrangement
(BNDN) Terminal Arrangement Screw 2-4.2 Mounting Holes
Screw 8 7 6 5
(or M4 Tapped Holes)

Terminal Blocks
2-4.2 Mounting Holes 8 5
4 3 2 1
(or M4 Tapped Holes) 4 1

26
62

45
62

45

26
4 max. 4.8 min. 14 13
4.2

14 13
4 max. 4.8 min.
4.2

12 11 10 9
12 9

(Top View) 18.5 (Top View)


18.5 5.9 max.
26 25 5.9 max. 26 25
3

3.2 min.
3

3.2 min.

Circuit Breakers

800-262-IDEC (4332) USA & Canada 797


RU Relays & Sockets

Dimensions cont (mm)


Switches & Pilot Lights

Finger-safe DIN Rail Mount Sockets


SM2S-05C SY4S-05C
30 30 35.5
35.5 DIN Rail 6 M3 Terminal DIN Rail
6 (BNDN) 25
M3 Terminal 25 Screw (BNDN) Terminal Arrangement
Screw Terminal Arrangement
2-4.2 Mounting Holes 2-4.2 Mounting Holes 8 7 6 5
(or M4 Tapped Holes) 5.5 18
5.5 18 8 5 (or M4 Tapped Holes) 4 3 2 1
4 1

4.2
4.2

46
64
26 26
64

46

14 13
Signaling Lights

14 13 12 11 10 9

Ring terminals
12 9 Ring terminals (Top View)
cannot be used. (Top View) cannot be used.
26 18.2
26 18.2
1.6

1.6
29
2

2
29

PCB Mount Sockets


SM2S-61 SM2S-62
13.2
Relays & Sockets

Terminal Arrangement 13.2 13.8 min. 8.2 min.**


Terminal Arrangement

4.1
1 4
4.1
10.4

5 8 1 4
25.4

10.4
31

5 8

9
9 12

16.8
0.3
29
9 12
9
13 14
16.8

13 14
0.3

27 3 (Bottom View)

1.4
21.2 3 (Bottom View)
9-2 holes
14.2 min.*

11 11
9-2 holes

12.2 min.*
15 15
1.4

(Tolerance 0.1)
* 19.2 min. when using (Tolerance 0.1)
1.5
hold-down springs 1.5 * 17.2 min. when using a hold-down spring.
21.2
** 13.2 min. when using a hold-down spring for
the relay with check button.

SY4S-61 SY4S-62
Timers

13.2 13.8 min. 13.2 8.2 min.**


8.8 8.8
4.4
4.4
Terminal Arrangement Terminal Arrangement
10.4

4.1
4.1

1 2 3 4
1 2 3 4

10.4
5 6 7 8

9
16.8
5 6 7 8
0.3
29
25.4

9 10 11 12
9
31

16.8

9 10 11 12 13 14
13 14

1.4
21.2 3 (Bottom View)
0.3

27 3 (Bottom View)
14.2 min.*

11 15-2 holes

12.2 min.*
11 15
15-2 holes
15 (Tolerance 0.1)
1.4

* 19.2 min. when using (Tolerance 0.1) 1.5 * 17.2 min. when using a hold-down spring.
1.5
hold-down springs
* *13.2 min. when using a hold-down spring for
Contactors

21.2
the relay with check button

Through Panel Mount Socket


SY4S-51
Panel Thickness: [27 (N1) + 21.4] + 0.5
0
1 to 2
Terminal Arrangement
1 2 3 4
Terminal Blocks

+0.2

5 6 7 8
0
25.4
31

9 10 11 12
25.6

13 14
0.3

27 3 (Bottom View) N: No. of sockets mounted


5.4 min.*

11
18.7

* 10.4 min. when using hold-down springs


2.4
21.2

Circuit Breakers

798 www.IDEC.com
Relays & Sockets RY/RM

RY/RM Series Miniature Relays

Switches & Pilot Lights


Key features:
RY2 (3A), RY4 (5A), RM2 (5A)
General purpose miniature relays
3A or 5A contact capacity
Wide variety of terminal styles and coil voltages meet a wide range of applications
All 4PDT types have arc barriers.

Signaling Lights
Part Number Selection
Part Number
Contact Model Plug-in Terminal PC Board Terminal Coil Voltage Code
Standard RY2S-U 0 RY2V-U 0
DPDT (Slim) 3A
With Indicator RY2S-UL 0 RY2V-UL 0
AC6V, AC12V, AC24V, AC110V, AC120V,

Relays & Sockets


With Check Button RY2S-UC 0 AC220V, AC240V
DC6V, DC12V, D24V, DC48V, DC110V
With Indicator and Check Button RY2S-ULC 0
Top Bracket Mounting RY2S-UT 0
With Diode (DC coil only) RY2S-UD 0 RY2V-UD 0 DC6V, DC12V, DC24V, DC48V, DC110V
Standard RM2S-U 0 RM2V-U 0
DPDT (Wide) 5A With Indicator RM2S-UL 0 RM2V-UL 0
RYAC6V, AC12V, AC24V, AC110-120V, AC220-240V
With Check Button RM2S-UC 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Check Button RM2S-ULC 0

Timers
Top Bracket Mounting RM2S-UT 0
With Diode (DC coil only) RM2S-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RM2S-ULD 0
Standard RY4S-U 0 RY4V-U 0

4PDT 5A With Indicator RY4S-UL 0 RY4V-UL 0


AC6V, AC12V, AC24V, AC110-120V,
With Check Button RY4S-UC 0 AC220-240V
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Check Button

Contactors
RY4S-ULC 0
Top Bracket Mounting RY4S-UT 0
With Diode (DC coil only) RY4S-UD 0
DC6V, DC12V, DC24V, DC48V, DC100-110V
With Indicator and Diode (DC coil only) RY4S-ULD 0

Top mount models are designed to mount directly to a panel and do not require a socket.
Ordering Information
When ordering, specify the Part No. and coil voltage code:
(example) RY4S-U AC110-120V
Part No. Coil Voltage Code Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 799


RY/RM Relays & Sockets

Sockets
Switches & Pilot Lights

Standard DIN Finger-safe DIN


Relays Through Panel Mount PCB Mount
RailMount RailMount
RY2S SY2S-05 SY2S-05C SY2S-51 SY2S-61
RM2 SM2S-05 SM2S-05C SM2S-51 SY4S-61
RY4S SY4S-05 SY4S-05C SY4S-51 SY4S-62
Signaling Lights

Hold Down Springs & Clips


For DIN For Through Panel &
Appearance Item Relay
Mount Socket PCB Mount Socket
Relays & Sockets

RY2S SY2S-02F1 SY4S-51F1


Pullover Wire
RM2
Spring
SY4S-51F1 SY4S-51F1
RY4S

RY2S
Leaf Spring 1
SFA-202 2 SFA-302
(side latch)
RM2, RY4S

RY2S
Leaf Spring 1
RM2 SFA-101 2 SFA-301
Timers

(top latch)
RY4S
1. Not available for PCB mount socket SY4S-62.
2. Order 2 pieces per relay.

Accessories
Item Appearance Use with Part No. Remarks
Contactors

The BNDN1000 is designed to accommodate DIN mount sockets.


Aluminum
Made of durable extruded aluminum, the BNDN1000 measures 0.413
DIN Rail All DIN rail sockets BNDN1000
(10.5mm) in height and 1.37 (35mm) in width (DIN standard). Standard
(1 meter length)
length is 39 (1,000mm).

DIN Rail End


DIN rail BNL5 9.1 mm wide.
Stop

Replacement
Horseshoe clip for all DIN rail For use on DIN rail mount socket when using pullover wire hold down
Hold-Down Y778-011
Terminal Blocks

sockets spring. 2 pieces included with each socket.


Spring Anchor
Circuit Breakers

800 www.IDEC.com
Relays & Sockets RY/RM

Specifications

Switches & Pilot Lights


Standard Contact
Contact Model
RY2 - DPDT Slim RM2 - DPDT Wide RY4 - 4PDT
Contact Material Gold-plated silver Silver Gold-plated silver
Contact Resistance 1 50 m maximum 30 m maximum 50 m maximum
24V DC, 5 mA; 5V DC, 24V DC, 10 mA; 5V DC, 24V DC, 5 mA; 5V DC,
Minimum Applicable Load
10 mA (reference value) 20 mA (reference value) 10 mA (reference value)
Operating Time 2 20 ms maximum
Release Time 2 20 ms maximum

Signaling Lights
Power Consumption AC: 1.1 VA (50 Hz), 1 VA (60 Hz) AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz) AC: 1.4 VA (50 Hz), 1.2 VA (60 Hz)
(approx.) DC: 0.8W DC: 0.9W DC: 0.9W
Insulation Resistance 100 M minimum (500V DC megger)
Between live and dead parts:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Between contact and coil:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Dielectric Strength

Relays & Sockets


Between contacts of different poles:
1500V AC, 1 minute 2000V AC, 1 minute 2000V AC, 1 minute
Between contacts of the same pole:
1000V AC, 1 minute 1000V AC, 1 minute 1000V AC, 1 minute
Electrical: 1800 operations/h maximum
Operating Frequency
Mechanical: 18,000 operations/h maximum
Damage limits: 10 to 55 Hz, amplitude 0.5 mm
Vibration Resistance
Operating extremes: 10 to 55 Hz, amplitude 0.5 mm
Damage limits: 1000 m/s2
Shock Resistance
Operating extremes: 100 m/s2 (DPDT Slim), 200 m/s2 (4PDT, DPDT Wide)

Timers
Mechanical Life 50,000,000 operations
100,000 operations (220V AC, 5A)
Electrical Life 200,000 operations (220V AC, 3A) 500,000 operations (220V AC, 5A)
200,000 operations (220V AC, 3A)
Operating Temperature 3 25 to +55C (no freezing) 25 to +45C (no freezing) 25 to +55C (no freezing) 4
Operating Humidity 45 to 85% RH (no condensation)
Weight (approx.) 23g 35g 34g

Note: Above values are initial values. 3. For use under different temperature conditions, refer to Continuous Load

Contactors
1. Measured using 5V DC, 1A voltage drop method Current vs. Operating Temperature Curve. The operating temperature range
2. Measured at the rated voltage (at 20C), excluding contact bouncing of relays with indicator or diode is 25 to +40C.
Release time of relays with diode: 40 ms maximum 4. When the total current of 4 contacts isless than 15A, the operating tem-
perature range is 25 to +70C.

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 801


RY/RM Relays & Sockets

AC Coil Ratings
Switches & Pilot Lights

Rated Current (mA) 15% at 20C Coil Resistance () 10% Operation Characteristics
AC 50Hz AC 60Hz at 20C (against rated values at 20C)
Voltage (V)
DPDT DPDT Wide & DPDT DPDT Wide & DPDT DPDT Wide & Max. Continuous Pickup Dropout
Slim 4PDT Slim 4PDT Slim 4PDT Applied Voltage Voltage Voltage
6 170 240 150 200 18.8 9.4
12 86 121 75 100 76.8 39.3
24 42 60.5 37 50 300 153
110 9.6 8.4 6,950
Signaling Lights

30%
110-120 9.4-10.8 8.0-9.2 4,290 110% 80% maximum
minimum
120 8.6 7.5 8,100
220 4.7 4.1 25,892
220-240 4.7-5.4 4.0-4.6 18,820
240 4.9 4.3 26,710

DC Coil Ratings
Relays & Sockets

Rated Current (mA) Coil Resistance () Operation Characteristics


15% at 20C 10% at 20C (against rated values at 20C)
Voltage (V)
Max. Continuous Pickup Dropout
DPDT Slim DPDT Wide & 4PDT DPDT Slim DPDT Wide & 4PDT
Applied Voltage Voltage Voltage
6 128 150 47 40
12 64 75 188 160
24 32 36.9 750 650
110% 80% maximum 10% minimum
48 18 18.5 2,660 2,600
100-110 8.2-9.0 12,250
110 8 13,800
Timers

Contact Ratings UL Ratings


Maximum Contact Capacity Resistive General use
Allowable Contact Power Rated Load Voltage DPDT DPDT DPDT DPDT
Continuous 4PDT 4PDT
Contact Slim Wide Slim Wide
Current Resistive Load Inductive Load Voltage (V) Res. Load Ind. Load
240V AC 3A 5A 5A 0.8A 2A 5A
110V AC 3A 1.5A
DPDT Slim 660 VA AC 176 VA AC 120V AC 1.5A 2.5A
Contactors

3A 220V AC 3A 0.8A
(RY2) 90W DC 45W DC
100V DC 0.2A 0.4A 0.2A 0.2A 0.2A
30V DC 3A 1.5A
30V DC 3A 5A 5A 3A 5A
110V AC 5A 2.5A
DPDT Wide 1100VA AC 440VA AC
5A 220V AC 5A 2A
(RM2) 150W DC 75W DC CSA Ratings
30V DC 5A 2.5A
Resistive General use
1200 VA AC 288 VA AC 240V AC 5A 1.2A Voltage
4PDT (RY4) 5A DPDT DPDT DPDT DPDT
150W DC 60W DC 30V DC 5A 2A 4PDT 4PDT
Slim Wide Slim Wide
Terminal Blocks

Note: Inductive load for the rated load cos = 0.3, L/R = 7 ms 240V AC 3A 5A 5A 0.8A 2A 5A
120V AC 3A 5A 1.5A 2.5A
TV Ratings 100V DC 0.2A 0.4A 0.2A
DPDT DPDT 30V DC 3A 5A 5A 1.5A 2.5A 1.5A
Voltage 4PDT
Slim Wide
240V AC 3A 5A 5A
30V DC 3A 5A 5A
AC: cos = 1.0, DC: L/R = 0 ms
Circuit Breakers

802 www.IDEC.com
Relays & Sockets RY/RM

Socket Specifications

Switches & Pilot Lights


Sockets Terminal Electrical Rating Wire Size Torque
SY2S-05 M3 screws with captive wire clamp 300V, 7A Maximum up to 2#14AWG 5.5 - 9 inlbs
DIN Rail
Mount SM2S-05 M3 screw with captive wire clamp 300V, 10A Maximum up to 2#14AWG 5.5 - 9 inlbs
Sockets
SY4S-05 M3 screw with captive wire clamp 300V, 7A* Maximum up to 2#14AWG 5.5 - 9 inlbs
SY2S-05C M3 screws with captive wire clamp, fingersafe 300V, 7A Maximum up to 2#14AWG 5.5 - 9 inlbs
Finger-safe
DIN Rail SM2S-05C M3 screw with captive wire clamp, fingersafe 300V, 10A Maximum up to 2#14AWG 5.5 - 9 inlbs
Mount
SY4S-05C M3 screw with captive wire clamp, fingersafe 300V, 7A* Maximum up to 2#14AWG 5.5 - 9 inlbs
SY2S-51 Solder 250V, 7A

Signaling Lights
Through
Panel Mount SM2S-51 Solder 250V, 10A
Socket
SY4S-51 Solder 250V, 7A*
SY2S-61 PCB Mount 300V, 7A
PCB Mount
SY4S-61 PCB Mount 300V, 7A
Socket
SY4S-62 PCB Mount 250V, 7A

* When using only 2 poles of the 4-poles, the UL recognized current is 10A.

Relays & Sockets


Timers
Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 803


RY/RM Relays & Sockets

Characteristics (Reference Data)


Switches & Pilot Lights

Electrical Life Curves


AC Load
(RY2) (RY4)

1000 1000

Life ( 10,000 operations)


110V AC resistive 500
500
220V AC resistive
Life ( 10,000 operations)

240V AC resistive
200
200

100
100
Signaling Lights

240V AC inductive
50
50

20 20
110V AC inductive
10 220V AC inductive 10
0 1 2 3 0 1 2 3 4 5
Load Current (A) Load Current (A)

(RM2) 110V AC resistive


220V AC resistive
Relays & Sockets

1000
Life ( 10,000 operations)

500

100

50
110V AC inductive
220V AC inductive

10
0 1 2 3 4 5
Load Current (A)
Timers

DC Load `
(RY2) 30V DC resistive (RY4)
1000 30V DC inductive 1000

500 500
Life ( 10,000 operations)
Life ( 10,000 operations)

200
200 30V DC resistive
100
Contactors

100 30V DC inductive


50
50

20 20
100V DC resistive
100V DC inductive 10
10
0 5 2 3 0 1 2 3 4 5
Load Current (A) Load Current (A)

(RM2)
30V DC resistive
Terminal Blocks

1000 30V DC inductive


Life ( 10,000 operations)

500

100

50
100V DC resistive
100V DC inductive
Circuit Breakers

10
0 1 2 3 4 5
Load Current (A)

804 www.IDEC.com
Relays & Sockets RY/RM

Maximum Switching Capacity

Switches & Pilot Lights


(RY4) AC resistive
(RY2) AC inductive
5 5

3 3
AC resistive
2

Load Current (A)


Load Current (A)

AC
inductive DC resistive
1 1
DC inductive DC resistive
0.5 0.5
DC inductive
0.3

Signaling Lights
0.2

0.1
1 5 10 50 100 200 300 1 10 20 30 50 100 200 300
Load Voltage (V) Load Voltage (V)

(RM2)
5
AC resistive

AC
Load Current (A)

inductive

1 DC inductive DC
resistive

Relays & Sockets


0.5

0.1
1 5 10 50 100 200 300
Load Voltage (V)

Continuous Load Current vs. Operating Temperature Curve (Standard Type, With Check Button, and Top Bracket Mounting Type)
(RM2) 100
(RY2) 100 (RY4) 100
90

Timers
90 90
80

Operating Temperature (C)


80 80
DC Coil DC Coil 70
Operating Temperature (C)
Operating Temperature (C)

70 DC Coil
70
60
60 60
AC Coil 50
50 50 AC Coil AC Coil
40 40 40

30 30 30

20 20 20

10 10 10

Contactors
0 0 0
1 2 3 1 2 3 1 2 3 4 5
Load Current (A) Load Current (A) Load Current (A)

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 805


RY/RM Relays & Sockets

Internal Connection (View from Bottom)


Switches & Pilot Lights

Standard Type
DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4) With Check Button

Front
Pushbutton

Contacts can be operated by pressing the


check button.
Signaling Lights

With Indicator (-L type)


DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4)

Coil Coil
Below Below
100V 24V AC/ When the relay is energized,
AC/DC DC the indicator goes on.
An LED protection diode
is not contained in DPDT
Relays & Sockets

relays for coils below 100V


DC.
Coil If coil polarity is reversed
Coil 24V
100V LED will not light.
AC/DC
AC/DC
and over
and over

With Diode (-D type)


DPDT Slim (RY2) DPDT Wide (RM2) 4PDT (RY4)
Timers

Contains a diode to absorb the back emf gener-


ated when the coil is de-energized. The release
time is slightly longer.
Diode Characteristics
Reverse withstand voltage: 1,000V
Forward current: 1A

With Indicator and Diode (-LD type)


DPDT Wide (RM2) 4PDT (RY4) DPDT Wide (RM2) 4PDT (RY4)
Contactors

1 4 1 2 3 4
5 8
Coil Coil 24V 9 12
5 6 7 8
Contains an LED
9 10 11 12
Below DC and indicator and a surge
24V DC over 13() (+)14 absorber.
13() (+)14
Terminal Blocks
Circuit Breakers

806 www.IDEC.com
Relays & Sockets RY/RM

Dimensions (mm)

Switches & Pilot Lights


RY2S RY4S RM2S
Total length from panel surface including relay socket Total length from the panel surface including relay socket.
Total length from the panel surface including relay socket SM2S-05: 61.5 (63.5) max., SM2S-51: 39.6 (41.6) max.
SY2S-05: 61.5 (63.5) max., SY2S-51: 39.6 (41.6) max. SY4S-05: 61.5 (63.5) max., SY4S-51: 39.6 (41.6) max.
Dimensions in the ( ) Dimensions in the ( )
3 1.2 oblong hole include a hold-down spring. 2.2 1.2 oblong hole Dimensions in the ( ) include a hold-down spring.
include a hold-down spring.

2.6
2.6 2.2 1.2 hole

2.6
1 4
5 8
1 4

27.5
9 12
5 8

0.5

Signaling Lights
1 2 3 4 13 14

27.5
0.5

9 12
5 6 7 8

13 14

27.5
0.5
9 10 11 12
35.6 max. 6.4 21
13 14

35.6 max. 5.4 14

35.6 max. 6.4 21

RY2V RY4V RM2V

Relays & Sockets


0.5 0.5
2.6
0.8

0.8
8-1 holes
4.1

0.8

14-1 holes 6.6 0.5

2.6
2.6

1 4
8-1 hole
7.15

5 8

4.1
27.5

12.7

9 12

4.1
0.5

1 2 3 4
7.15
6.4

13 14 5 6 7 8

1 4
27.5
0.5

12.7
9 10 11 12
5 8

6.4
13 14

27.5
9 12

12.7
35.6 max. 4 14 4.4

0.5
13 14

35.6 max. 4 21 4.4 4.4

6.4
13.2

7.15
4.4 35.6 max. 4 21

Timers
RY2S-UT RY4S-UT RM2S-UT
2.6
4.4

13.2
4.4
4.4

3 1.2 oblong hole


2.6

2.6
2.2 1.2 hole
4.4

2.2 1.2 oblong hole


4.1
0.5

4.1
0.5
0.5
4.1

Contactors
1 4
1 4
5 8 1 2 3 4
5 8
6.3

5 6 7 8
43.2

27.5

6.3
9 12
38

43.2

27.5
6.3

9 12
38
43.2

27.5

9 10 11 12
38

13 14
13 14
13 14

6.4
6.4
6.4

3.5 2 3.5 2 3.5 2


14.5 35.6 max. 5.4 21.5 35.6 max. 6.4 21.5 35.6 max. 6.4

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 807


RY/RM Relays & Sockets

Dimensions
Switches & Pilot Lights

Standard DIN Rail Mount Sockets


SY2S-05 SM2S-05
17 30 31.5
31.5

0.7
6 6 18
18 DIN Rail DIN Rail
M3 Terminal M3 Terminal
(BNDN) Terminal Arrangement (BNDN) Terminal Arrangement
Screw Screw
2-4.2 Mounting Holes 8 5
8 5 2-4.2 Mounting Holes
(or M4 Tapped Holes) (or M4 Tapped Holes) 4 1
4 1

62

45
62

45

16 26
14 13
4 max. 4.8 min.

4.2
4 max. 4.8 min. 14 13
Signaling Lights

4.2

12 9
12 9

(Top View) 18.5 (Top View)


16 14.5
26 25 5.9 max.
5.9 max.

3
20 25
2

3.2 min.
3.2 min.

SY4S-05
30
31.5
0.7

6
DIN Rail
M3 Terminal 18 (BNDN) Terminal Arrangement
Screw 2-4.2 Mounting Holes
8 7 6 5
(or M4 Tapped Holes)
4 3 2 1
Relays & Sockets

26
62

45

4 max. 4.8 min. 14 13


4.2

12 11 10 9

18.5 (Top View)


5.9 max.
26 25
3

3.2 min.

Finger-safe DIN Rail Mount Sockets


SY2S-05C SM2S-05C
17.2 35.5 30
M3 Terminal 35.5 DIN Rail
Timers

6 DIN Rail 6
Screw 25 Terminal Arrangement M3 Terminal 25 (BNDN)
(BNDN) 2-4.2 Mounting Holes Terminal Arrangement
Screw
8 5 2-4.2 Mounting Holes
(or M4 Tapped Holes)
5 4 1 5.5 18 (or M4 Tapped Holes) 8 5
4 1
4.2

4.2

16
26
64

46

64

46

14 13
12 9 14 13
Ring terminals (Top View) 12 9
Ring terminals
cannot be used. (Top View)
16 18.2 cannot be used.
26 18.2
1.6

20 29
1.6
2

29
Contactors

SY4S-05C
30 35.5
6 M3 Terminal DIN Rail
25
Screw (BNDN) Terminal Arrangement
2-4.2 Mounting Holes 8 7 6 5
5.5 18
(or M4 Tapped Holes) 4 3 2 1
4.2

46
64

26

14 13
12 11 10 9
Ring terminals
Terminal Blocks

(Top View)
cannot be used.
26 18.2
1.6

29
2
Circuit Breakers

808 www.IDEC.com
Relays & Sockets RY/RM

Through Panel Mount Socket

Switches & Pilot Lights


SY2S-51 SM2S-51
Panel Thickness: [18(N1)+12.4] +0.5 Panel Thickness: +0.5
0 1 to 2 [27 (N1) + 21.4]
1 to 2 0
Terminal Arrangement
Terminal Arrangement
1 4

+0.2
0
1 4

+0.2
5 8

25.4

25.6
31
5 8 9 12

25.4
31

25.6
9 12 13 14
13 14

0.3
27 3 (Bottom View) N: No. of sockets mounted
0.3

5.4 min.*
18 3 (Bottom View) N: No. of sockets mounted 11

5.4 min.*
11 18.7
18.7 2.4 * 10.4 min. when using hold-down springs
21.2
2.4 * 10.4 min. when husing hold-down springs

Signaling Lights
12.2

SY4S-51
Panel Thickness: [27 (N1) + 21.4] + 0.5
0
1 to 2
Terminal Arrangement
1 2 3 4
+0.2

5 6 7 8
0
25.4
31

9 10 11 12
25.6

13 14
0.3

27 3 (Bottom View) N: No. of sockets mounted


5.4 min.*

11

Relays & Sockets


18.7

* 10.4 min. when using hold-down springs


2.4
21.2

PCB Mount Sockets


SY2S-61 SY4S-61
13.6 min. 13.2 13.8 min.
4.4
10.4

Terminal Arrangement 8.8


4.1

4.4
1 4 Terminal Arrangement

10.4

Timers
4.1
5 8
9
25.4

1 2 3 4
31

16.8

9 12
25.4 5 6 7 8

9
13 14
31

16.8
9 10 11 12
14.2 min.*

13
0.3

(Bottom View) 14
18 3
0.3

27 3 (Bottom View)

14.2 min.*
11 8-2 holes
11
15 15-2 holes
* 19.2 min. when using (Tolerance 0.1) 15

1.4
1.5 hold-down springs
* 19.2 min. when using (Tolerance 0.1)
1.5
12.2 hold-down springs
21.2

SY4S-62

Contactors
13.2 8.2 min.**
8.8
4.4
Terminal Arrangement
4.1

1 2 3 4
10.4

5 6 7 8
9
16.8
0.3
29

9 10 11 12
13 14
1.4

21.2 3 (Bottom View)


11 15-2 holes
12.2 min.*

15

Terminal Blocks
(Tolerance 0.1)

1.5 * 17.2 min. when using a hold-down spring.


* *13.2 min. when using a hold-down spring for
the relay with check button
Circuit Breakers

800-262-IDEC (4332) USA & Canada 809


RF1V Relays & Sockets

RF1V Force Guided Relays/SF1V Relay Sockets


Switches & Pilot Lights

Key features:
Compact and EN compliant RF1V force guided relays
Force guided contact mechanism
(EN50205 Type A TV approved)
Contact configuration
4-pole (2NO-2NC, 3NO-1NC)
6-pole (4NO-2NC, 5NO-1NC, 3NO-3NC)
Built-in LED indicator available.
Signaling Lights

Fast response time (8 ms maximum).


High shock resistance (200 m/s2 minimum)
Finger-safe DIN rail mount socket and PC board mount socket.

Certification Organization/
Applicable Standard Marking
File Number

UL508
UL/c-UL File No. E55996
CSA C22.2 No.14
Relays & Sockets

EN50205
TV SD
EN61810-1

Part Number Selection


Part Number
Contact Without LED Indicator With LED Indicator Rated Coil Voltage
RF1V-2A2B-D12 RF1V-2A2BL-D12 12V DC
2NO-2NC RF1V-2A2B-D24 RF1V-2A2BL-D24 24V DC
Timers

RF1V-2A2B-D48 RF1V-2A2BL-D48 48V DC


4-pole
RF1V-3A1B-D12 RF1V-3A1BL-D12 12V DC
3NO-1NC RF1V-3A1B-D24 RF1V-3A1BL-D24 24V DC
RF1V-3A1B-D48 RF1V-3A1BL-D48 48V DC
RF1V-4A2B-D12 RF1V-4A2BL-D12 12V DC
4NO-2NC RF1V-4A2B-D24 RF1V-4A2BL-D24 24V DC
RF1V-4A2B-D48 RF1V-4A2BL-D48 48V DC
Contactors

RF1V-5A1B-D12 RF1V-5A1BL-D12 12V DC


6-pole 5NO-1NC RF1V-5A1B-D24 RF1V-5A1BL-D24 24V DC
RF1V-5A1B-D48 RF1V-5A1BL-D48 48V DC
RF1V-3A3B-D12 RF1V-3A3BL-D12 12V DC
3NO-3NC RF1V-3A3B-D24 RF1V-3A3BL-D24 24V DC
RF1V-3A3B-D48 RF1V-3A3BL-D48 48V DC
Terminal Blocks

Sockets Certification for Sockets


Style No. of Poles Ordering Type No. Certification Organization/
Applicable Standard Marking
File Number
4 SF1V-4-07L UL508
DIN Rail UL/c-UL File No. E62437
CSA C22.2 No.14
Mount Sockets
6 SF1V-6-07L
TV SD
EN147000
Circuit Breakers

4 SF1V-4-61 EN147100
PC Board EC Low Voltage Directive
Mount Sockets (DIN rail mount sockets only)
6 SF1V-6-61

810 www.IDEC.com
Relays & Sockets RF1V

Coil Ratings

Switches & Pilot Lights


Operating Characteristics
Rated Current Coil (at 20C)
Rated Coil Power
Contact (mA) 10% Resistance ()
Voltage (V) Maximum Continuous Consumption
(at 20C) 1 10% (at 20C) Pickup Voltage Dropout Voltage
Applied Voltage 2
12V DC 30 400
2NO-2NC 24V DC 15 1600
48V DC 7.5 6400
4-pole Approx. 0.36W
12V DC 30 400

Signaling Lights
3NO-1NC 24V DC 15 1600
48V DC 7.5 6400
12V DC 41.7 288
4NO-2NC 24V DC 20.8 1152 75% maximum 10% minimum 110%
48V DC 10.4 4608
12V DC 41.7 288
6-pole 5NO-1NC 24V DC 20.8 1152 Approx. 0.5W

Relays & Sockets


48V DC 10.4 4608
12V DC 41.7 288
3NO-3NC 24V DC 20.8 1152
48V DC 10.4 4608
1. For relays with LED indicator, the rated current increases by approx. 2 mA.
2. Maximum continuous applied voltage is the maximum voltage that can be applied to relay coils.

Accessories
Item Appearance Specifications Type No. Remarks

Timers
Aluminum Length: 1m
DIN Rail BNDN1000
Weight: Approx. 250g Width: 35 mm

BNL5
Metal (zinc plated steel)
End Clip
Weight: Approx. 15g
BNL6

Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 811


RF1V Relays & Sockets

Specifications
Switches & Pilot Lights

Number of Poles 4-pole 6-pole


Contact Configuration 2NO-2NC 3NO-1NC 4NO-2NC 5NO-1NC 3NO-3NC
Contact Resistance (initial value) 1
100 m maximum
Contact Material AgSnO2 (Au flashed)
Rated Load (resistive load) 6A 250V AC, 6A 30V DC
Allowable Switching Power (resistive load) 1500 VA, 180W
Allowable Switching Voltage 250V AC, 30V DC
Allowable Switching Current 6A
Signaling Lights

Minimum Applicable Load 2


5V DC, 1 mA (reference value)
Power Consumption (approx.) 0.36W 0.5W
Insulation Resistance 1000 M minimum (500V DC megger, same measurement positions as the dielectric strength)
Between contact and coil 4000V AC, 1 minute
2500V AC, 1 minute
2500V AC, 1 minute Between contacts 7-8 and 11-12
Between contacts 7-8 and 9-10 Between contacts 9-10 and 13-14
Between contacts 11-12 and 13-14
Relays & Sockets

Dielectric
Between contacts of different poles 4000V AC, 1 min.
Strength 4000V AC, 1 min.
Between contacts 3-4 and 5-6
Between contacts 3-4 and 5-6
Between contacts 3-4 and 7-8
Between contacts 3-4 and 7-8
Between contacts 5-6 and 9-10
Between contacts 5-6 and 9-10
Between contacts 7-8 and 9-10
Between contacts of the same pole 1500V AC, 1 minute
Operating Time (at 20C) 20 ms maximum (at the rated coil voltage, excluding contact bounce time)
Response Time (at 20C) 3 8 ms maximum (at the rated coil voltage, excluding contact bounce time)
Release Time (at 20C) 20 ms maximum (at the rated coil voltage, excluding contact bounce time)
Operating Extremes 10 to 55 Hz, amplitude 0.75 mm
Timers

Vibration
Resistance Damage Limits 10 to 55 Hz, amplitude 0.75 mm
Shock Operating Extremes (half sine-wave pulse: 11 ms) 200 m/s2, when mounted on DIN rail mount socket: 150 m/s2
Resistance Damage Limits (half sine-wave pulse: 6 ms) 1000 m/s2
250V AC 6A resistive load: 100,000 operations minimum (operating frequency 1200 per hour)
30V DC 6A resistive load: 100,000 operations minimum (operating frequency 1200 per hour)
250V AC 1A resistive load: 500,000 operations minimum (operating frequency 1800 per hour)
Electrical Life
30V DC 1A resistive load: 500,000 operations minimum (operating frequency 1800 per hour)
[AC 15] 240V AC 2A inductive load: 100,000 operations minimum (operating frequency 1200 per hour, cos = 0.3)
Contactors

[DC 13] 24V DC 1A inductive load: 100,000 operations minimum (operating frequency 1200 per hour, L/R = 48 ms)
Mechanical Life 10 million operations minimum (operating frequency 10,800 operations per hour)
Operating Temperature 4
40 to +85C (no freezing)
Operating Humidity 5 to 85%RH (no condensation)
Storage Temperature 40 to +85C
Operating Frequency (rated load) 1200 operations per hour
Weight (approx.) 20g 23g
Terminal Blocks

1. Measured using 6V DC,1A voltage drop method. 3. Response time is the time until NO contact opens, after the coil voltage is turned off.
2. Failure rate level P (reference value) 4. When using at 70 to 85C, reduce the switching current by 0.1A/C.
Circuit Breakers

812 www.IDEC.com
Relays & Sockets RF1V

Socket Specifications Applicable Crimping Terminals Specifications

Switches & Pilot Lights


Part Number SF1V-4-07L SF1V-6-07L SF1V-4-61 SF1V-6-61

6.3 max.

3.0 min.
Rated Current 6A
Rated Voltage 250V AC/DC
1000 M minimum
Insulation Resistance
(500V DC megger, between terminals)
Dielectric Strength 2500V AC, 1 minute (between terminals) 4.0 max. 6.5 min.

Screw Terminal Style M3 slotted Phillips screw


Applicable Wire 0.7 to 1.65 mm2 (18 AWG to 14 AWG) Note: Ring tongue terminals cannot be used.

Signaling Lights
Recommended Screw
0.5 to 0.8 Nm
Tightening Torque
Terminal Strength Wire tensile strength: 50N min.
Damage limits: 10 to 55 Hz, amplitude 0.75 mm
Vibration Resistance
Resonance: 10 to 55 Hz, amplitude 0.75 mm
Shock Resistance 1000 m/s2
Operating Temperature 1
40 to +85C (no freezing)
Operating Humidity 5 to 85% RH (no condensation)

Relays & Sockets


Storage Humidity 40 to +85C
Degree of Protection IP20 (finger-safe screw terminals)
Weight (approx.) 40g 55g 9g 10g
1. When using at 70 to 85C, reduce the switching current by 0.1A/C.

Characteristics
Maximum Switching Capacity Electrical Life Curve Notes on Contact Gaps except Welded Contacts
500

Timers
1 3 4 7 8

+
Example: RF1V-2A2B-D24
Life (10,000 operations)

AC Resistive Load 100


10
Load Current (A)

6 2 5 6 9 10

250V AC Resistive Load


DC Resistive Load
1
10 30V DC Resistive Load
If the NO contact (7-8 or 9-10) welds, the NC contact (3-4 or 5-6)
remains open even when the relay coil is de-energized, maintain-
ing a gap of 0.5 mm. The remaining unwelded NO contact (9-10 or
7-8) is either open or closed.

Contactors
0.1 1
1 10 100 250 0.1 1 10 If the NC contact (3-4 or 5-6) welds, the NO contact (7-8 or 9-10)
Load Voltage (V) Load Current (A)
remains open even when the relay coil is energized, maintaining a
gap of 0.5 mm. The remaining unwelded NC contact (5-6 or 3-4) is
either open or closed.

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 813


RF1V Relays & Sockets

RF1V Dimensions (mm)


Switches & Pilot Lights

RF1V (4-pole) RF1V (6-pole) PC Board Terminal type Mounting Hole


Layout (Bottom View)
40 max. 50 max.
RF1V (4-pole)
le
ho
.4
-1
10
13 max.
13 max.

5.08 0.1

10.16 0.1
(1.83)
13.970.1 11.43 0.1
24 max.
Signaling Lights

24 max.
5.08

RF1V (6-pole)
1.0 1.83 0.5
1.0 1.83
3.5

0.5 le

3.5
10.16 13.97 5.08
10.16 13.97 5.08 ho
1.4
5.08 11.43
5.08 1 4-
5.08 5.08
11.43

(1.83) 5.08 0.1

10.16 0.1
13.97 0.1 5.08 0.1
5.08 0.1 5.08 0.1
Relays & Sockets

11.43 0.1

Internal Connection (View from Bottom)


With Indicator and Diode (-LD type)
RF1V (4-pole) RF1V (6-pole)
Without LED Indicator Without LED Indicator
1 13 4 3 74 8 7 8 1 13 4 3 74 8 7 8 11 33 44 77 88 11
11 12
12 11 33 44 77 88 11
11 12
12 11 33 44 77 88 11
11 12
12
+ 1 + 13 4 3 74 8 7 8 + 1 + 13 4 3 74 8 7 8 ++ 11 33 44 77 88 11
11 12
12 ++ 11 33 44 77 88 11
11 12
12 ++ 11 33 44 77 88 11
11 12
12

+
+
+
+ +
+ +
+ +
+
22 55 66 99 10
10 13
13 14
14 22 55 66 99 10
10 13
13 14
14 22 55 66 99 10
10 13
13 14
14
2 25 6 5 96 10 9 10 2 25 6 5 96 10 9 10
Timers

22 55 66
4NO-2NC
4NO-2NC 99 10
10 13
Contact
Contact13 14
14 22 55 66
5NO-1NC
5NO-1NC 99 10
10 13
Contact
Contact13 14
14 22 55 66
3NO-3NC
3NO-3NC 99 10
10 13
Contact
Contact13 14
14
25 2NO-2NC
2 2NO-2NC 6 Contact Contact
5 96 10 9 10 2 3NO-1NC
253NO-1NC
6 Contact Contact
5 96 10 9 10
2NO-2NC
2NO-2NC
ContactContact 3NO-1NC
3NO-1NC
ContactContact 4NO-2NC
4NO-2NC Contact
Contact 5NO-1NC
5NO-1NC Contact
Contact 3NO-3NC
3NO-3NC Contact
Contact

With LED Indicator With LED Indicator


1 13 4 3 74 8 7 8 1 13 4 3 74 8 7 8 11 33 44 77 88 11
11 12
12 11 33 44 77 88 11
11 12
12 11 33 44 77 88 11
11 12
12
+ 1 + 13 4 3 74 8 7 8 + 1 + 13 4 3 74 8 7 8 ++ 11 33 44 77 88 11
11 12
12 ++ 11 33 44 77 88 11
11 12
12 ++ 11 33 44 77 88 11
11 12
12

+
+
+
+ +
+ +
+ +
+
2 25 6 5 96 10
9 10 2 22 55 66 99 10
10 13
13 14
14 22 55 66 99 10
10 13
13 14
14 22 55 66 99 10
10 13
13 14
14
25 6 5 96 10 9 10
2 2NO-2NC
25 2NO-2NC
6 Contact Contact
5 96 10 9 10 2 3NO1NC
25 3NO1NC
6 ContactContact
5 96 10 9 10 22 55 66
4NO-2NC
4NO-2NC 99 10
10 13
Contact
Contact13 14
14 22 55 66 Contact
5NO-1NC
5NO-1NC 99 10
10 13
Contact13 14
14 22 55 66
3NO-3NC
3NO-3NC 99 10
10 13
13 14
Contact
Contact 14

2NO-2NC
2NO-2NC
ContactContact 3NO1NC
3NO1NC
ContactContact 4NO-2NC
4NO-2NC Contact
Contact 5NO-1NC
5NO-1NC Contact
Contact 3NO-3NC
3NO-3NC Contact
Contact
Contactors
Terminal Blocks
Circuit Breakers

814 www.IDEC.com
Relays & Sockets RF1V

SF1V DIN Rail Mount Socket Dimensions (mm)

Switches & Pilot Lights


SF1V-4-07L (4-pole) SF1V-6-07L (6-pole)
(Internal Connection) 4 (Internal Connection) 4

6.5

6.5
5
5
10 7 8 14 12

9 M3 Terminal 13 11
Screw M3 Terminal
10 8 Screw
6

5 9 7

75

75

Signaling Lights
4 6 4
6.2 6.2
3 2 1 5 2 1 3

(Top View) (Top View)

R2

6.5
R2
6.5
6.3 6.3

Relays & Sockets


58.9
62.4
62.4
58.9

5.3
5.3

29.8
22.4 35.4

4
35.4
4

(Panel Mounting Hole Layout) (Panel Mounting Hole Layout)


80.0 0.2 2M3.5 or 4 holes 80.0 0.2 2M3.5 or 4 holes

Timers
0.2
22
14.5 0.2

(Top View)
(Top View)

Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 815


RF1V Relays & Sockets

SF1V PC Board Mount Sockets


Switches & Pilot Lights

SF1V-4-07L (4-pole) SF1V-6-07L (6-pole)

15 max.
15 max.
60 max.
50 max.
Signaling Lights

40 max.
40 max.

6.2

3.6
6.2

3.5
3.6
3.5

(13) (13)

0.6
(13) 0.8
(13) 6.93 0.4 10.16
0.6
0.8
6.93 0.4 13.97 5.08
10.16
13.97 5.08 5.08 5.08
5.08 11.43 5.08
11.43
Relays & Sockets

3-3.2 holes for M3 self-tapping screws 3-3.2 holes for M3 self-tapping screws
le
ho le
39.90.1 .1 49.90.1 ho
1 .1
4.10.1 24.8 0.1 - 4.10.1 24.80.1 -1
10 14

1 3 4 7 8 1 3 4 7 8 11 12

2 5 6 9 10 2 5 6 9 10 13 14

(6.93 5.08 0.1 (6.93) 5.08


10.16 0.1

10.16 0.1

13.97 0.1 11.43 0.1 13.97 0.1 5.08 0.1


5.08 0.1 5.08 0.1 5.08 0.1
11.43 0.1
Timers
Contactors
Terminal Blocks
Circuit Breakers

816 www.IDEC.com
Relays & Sockets Operating Instructions

Operating Instructions

Switches & Pilot Lights


Driving Circuit for Relays Protection for Relay Contacts
1. To ensure correct relay operation, apply rated voltage to the relay coil. 1. The contact ratings show maximum values. Make sure that these values are
not exceeded. When an inrush current flows through the load, the contact
2. Input voltage for the DC coil: may become welded. If this is the case, connect a contact protection circuit,
A complete DC voltage is best for the coil power to make sure of stable relay such as a current limiting resistor.
operation. When using a power supply containing a ripple voltage, suppress
the ripple factor within 5%. When power is supplied through a rectification 2. Contact protection circuit:
circuit, the relay operating characteristics, such as pickup voltage and dropout When switching an inductive load, arcing causes carbides to form on the
voltage, depend on the ripple factor. Connect a smoothing capacitor for better contacts, resulting in increased contact resistance. In consideration of contact

Signaling Lights
operating characteristics as shown below. reliability, contact life, and noise suppression, use of a surge absorbing circuit
Pulsation is recommended. Note that the release time of the load becomes slightly
longer. Check the operation using the actual load. Incorrect use of a contact
Smoothing
protection circuit will adversely affect switching characteristics. Four typical
Emin Emax Emean DC
Capacitor examples of contact protection circuits are shown in the following table:
+
R Relay Emax Emin
Ripple Factor (%) 100%
Emean This protection circuit can be used when the load
Emax = Maximum of pulsating current impedance is smaller than the RC impedance in an
Emin = Minimum of pulsating current
Emean = DC mean value AC load power circuit.
Power Ind. Load
R: Resistor of approximately the same resistance

Relays & Sockets


C R

3. Leakage current while relay is off: value as the load


When driving an element at the same time as the relay operation, special C:0.1 to 1 F

RC
consideration is needed for the circuit design. As shown in the incorrect This protection circuit can be used for both AC and
circuit below, leakage current (Io) flows through the relay coil while the relay DC load power circuits.
is off. Leakage current causes coil release failure or adversely affects the R: Resistor of approximately the same resistance
vibration resistance and shock resistance. Design a circuit as shown in the value as the load
C: 0.1 to 1 F
correct example.
This protection circuit can be used for DC load power

Incorrect Correct + circuits. Use a diode with the following ratings.
Diode

R TE R Power D Ind. Load Reverse withstand voltage: Power voltage of the


load circuit x 10

Timers
Io
Forward current: More than the load current

This protection circuit can be used for both AC and
4. Surge suppression for transistor driving circuits: DC load power circuits.
Varistor

For a best result, when using a power voltage of 24


When the relay coil is turned off, a high-voltage pulse is generated, causing a
Varistor

Power Ind. Load


to 48V AC/DC, connect a varistor across the load.
transistor to deteriorate and sometimes to break. Be sure to connect a diode When using a power voltage of 100 to 240V AC/DC,
to suppress the back electromotive force. Then, the coil release time becomes connect a varistor across the contacts.
slightly longer. To shorten the coil release time, connect a Zener diode
between the collector and emitter of the transistor. Select a Zener diode with 3. Do not use a contact protection circuit as shown below:

Contactors
a Zener voltage slightly higher than the power voltage.
This protection circuit is very effective in arc suppression when
Back emf
suppressing diode opening the contacts. But, the capacitor is charged while the
+
C
Load contacts are opened. When the contacts are closed, the capacitor
Power

R Relay is discharged through the contacts, increasing the possibility of
contact welding.

This protection circuit is very effective in arc suppression when


C
Load opening the contacts. But, when the contacts are closed, a current
Power
flows to charge the capacitor, causing contact welding.

Generally, switching a DC inductive load is more difficult than switching a DC Terminal Blocks
resistive load. Using an appropriate arc suppressor, however, will improve the
switching characteristics of a DC inductive load.

Soldering
1. When soldering the relay terminals, use a soldering iron of 30 to 60W, and
quickly complete soldering (within approximately 3 seconds).
Circuit Breakers

2. Use a non-corrosive rosin flux.

800-262-IDEC (4332) USA & Canada 817


Operating Instructions Relays & Sockets

Operating Instructions cont


Switches & Pilot Lights

Other Precautions
1. General notice: 2. UL and CSA ratings may differ from product rated values determined by IDEC.
To maintain the initial characteristics, do not drop or shock the relay.
3. Do not use relays in the vicinity of strong magnetic field, as this may affect
The relay cover cannot be removed from the base during normal operation. To relay operation.
maintain the initial characteristics, do not remove the relay cover.

Use the relay in environments free from condensation, dust, sulfur dioxide
(SO2), and hydrogen sulfide (H2S).
Signaling Lights

Make sure that the coil voltage does not exceed applicable coil voltagerange.

Safety Precautions
Turn off the power to the relay before starting installation, removal, wiring, Precautions for the RU Relays
maintenance, and inspection of the relays. Failure to turn power off may
cause electrical shock or fire hazard. Before operating the latching lever of the RU relay, turn off the power to
theRU relay. After checking the circuit, return the latching lever to the origi-
Relays & Sockets

Observe specifications and rated values, otherwise electrical shock or fire nalposition.
hazard may be caused.
Do not use the latching lever as a switch. The durability of the latching lever
Use wires of the proper size to meet voltage and current requirements. Tight- is a minimum of 100 operations.
en the terminal screws on the relay socket to the proper tightening torque.
When using DC loads on 4PDT relays, apply a positive voltage to terminals of
Surge absorbing elements on AC relays with RC or DC relays with diode are neighboring poles and a negative voltage to the other terminals of neighbor-
provided to absorb the back electromotive force generated by the coil. When ing poles to prevent the possibility of short circuits.
the relay is subject to an excessive external surge voltage, the surge absorb-
ing element may be damaged. Add another surge absorbing provision to the DC relays with a diode have a polarity in the coil terminals. Apply the DC volt-
relay to prevent damage. age to the correct terminals.
Timers
Contactors
Terminal Blocks
Circuit Breakers

818 www.IDEC.com
Relays & Sockets RSC

RSC Series Solid State Relays

Switches & Pilot Lights


Key features:
Slim design allows for DIN rail or panel mounting
Built-in heat sink maximizes current output capability
Epoxy-free design
Choice of 20A, 30A and 45A models
LED indicator
Finger-safe terminals
Zero voltage switching

Signaling Lights
Back-to-back SCR output
Direct Bond Copper (DBC) substrate construction
Built-in transient protection (TVS)
100k-cycle UL508 endurance rating
UL Recognized, TUV Approved, CE Marked
Lead free and RoHS compliant
EMC (Level 3) & IEC 62314 compliant

Relays & Sockets


UL Recognized
File No. E194577

Part Number Selection Specifications


Output Current Part Model 20A 30A 45A
Input Control Voltage
Rating Number
-20 to +80
20A RSCDN-20A Operating temperature (C) -20 to +60 (90-140 V AC input
models)

Timers
4-32V DC 30A RSCDN-30A
Storage temperature (C) -40 to +100
45A RSCDN-45A
Input-to-Output isolation voltage (Vrms) 4200
20A RSCA1N-20A
90-140V AC 30A RSCA1N-30A Input/Output to ground isolation voltage
4000
(Vrms)
45A RSCA1N-45A
General Characteristics

Operating frequency (Hz) 47 to 63


180-280V AC
20A RSCA2N-20A UL94-V0 Self-extinguishing
Housing material
polycarbonate

Contactors
Heat sink material Anodized aluminum black
30A RSCA2N-30A Protection (IEC 60529) - Casing IP20
Input terminal wire size (stranded and
16 AWG to 24 AWG
solid)
45A RSCA2N-45A*
Input terminal tightening torque (Nm) 0.5

*Input control voltage is 180-260V AC. Output terminal wire size (stranded) 8 AWG to 16 AWG
Output terminal wire size (solid) 10 AWG to 16 AWG

Terminal Blocks
Output terminal tightening torque (Nm) 1.3
Weight (g) 225 400
Circuit Breakers

800-262-IDEC (4332) USA & Canada 819


RSC Relays & Sockets

Specifications cont
Switches & Pilot Lights

Model 20A 30A 45A


IEC 62314 IEC 60947-4-3 (AC 51)
IEC 60947-4-2 (AC 53a) CE compliant with LVD 73/23/EEC
Conformity to standards
TUV certified per EN 60950 c-UR per C22.2.no. 14-95
UL recognized per UL 508
Vibrations according to IEC/
35 mm / 10-55 Hz
EN60068-2-6
Shock test IEC 60068-2-27 15 G / 11 ms
Immunity to electrostatic
Level 3
Signaling Lights

discharges IEC/EN 61000-4-2


Immunity to electrostatic fields
Safety Standards

Level 3
ENV 50140/204 (IEC 1000-4-3)
Immunity to rapid transient
Level 3
bursts to IEC 1000-4-4
Immunity to shock waves ac-
Level 3
cording to IEC/EN 61000-4-5
Immunity to radio frequency in
Relays & Sockets

common mode acc. to ENV (CEI Level 3


1000-4-6)
Conducted and radiated noise
for industrial environments per Class A
CISPR 11
Pollution Degree 2
Overvoltage Category III

Model 20A, 30A, 45A


Input voltage (V) 4-32V DC 90-140V AC 180-280V AC*
Timers

Input Specifications

Turn-off voltage (V) 1 10 10


Max. controlled current (mA) 20 6 8
Min. input current (mA) 16 5 6
Turn-on time (ms) 8.33 (60Hz) / 10 (50Hz) 30 30
Max. turn-off time (ms) 8.33 (60Hz) / 10 (50Hz) 30 30
1. LED is not an absolute indicator of power being present.
2. *45A model is 180-260V AC
Contactors

Model 20A 30A 45A


Voltage range (Vrms max) 48-600 48-600 48-600
Non-rep. peak voltage (Vpeak) 1100 1100 1100
Maximum off-state leakage at Vmax
120 120 120
and T = 25 C (A)
Current max @ 40C (A) 20 30 45
Terminal Blocks

Minimum current (mA) 100 100 100


Output Specifications

On-state voltage drop at I max (Vpeak) 1.2 1.2 1.35


I2t (t = 10 ms) (A2s) (50/60 Hz) 1225/1020 2850/2350 3200/2600
Static (off-state) dv/dt (V/s) 500 500 500
HP ratings at 120V 1/2 3/4 1.5
HP ratings at 240V 1 2 3
HP ratings at 480V 5
Utilization category AC-51 (A) 20 30 45
Circuit Breakers

Utilization Category AC-53 (A) 6 9 10


Max. non-rep. 1 s surge (T=25C) (A) 100 150 160
Max. non-rep.1-cycle surge (T=25C) (A) 495 750 800

820 www.IDEC.com
Switches & Pilot Lights Signaling Lights Relays & Sockets Timers Contactors Terminal Blocks Circuit Breakers
RSC

821
Dimensions (mm)
20A/30A Models
Relays & Sockets

800-262-IDEC (4332) USA & Canada


45A Model
RSS Relays & Sockets

RSS Series Panel Mount Solid State Relays


Switches & Pilot Lights

Key features:
Input status LED Indicator
Dual SCR output
Direct bond copper substrate
Internal transient protection built-in snubber
EMC compliant (level 3)
Photo isolation
1200 Volt blocking voltage
Signaling Lights

4000 Volt optical isolation


Zero voltage turn-on
High surge capability
Optional fingersafe terminal cover (RSS-CVR)
UL Recognized
File No. E194577
Relays & Sockets

Part Number Selection Specifications


Continuous Series RSSDN RSSAN
Input Part Number
Output Current
Voltage Range 4 to 32V DC 90 to 280V AC
10A RSSAN-10A
Input Current current regulated (10mA)
Input Specifications

25A RSSAN-25A
AC Input Pick Up Voltage 4V DC 90V AC
90-280V AC 50A RSSAN-50A
Drop Out Voltage 1V DC 10V AC
75A RSSAN-75A
Dielectric Strength
Timers

4000 RMS (min) 4000 RMS (min)


90A RSSAN-90A (Input-Output-Base)
10A RSSDN-10A Capacitance (Input to Output) 8pF 8pF
25A RSSDN-25A Rev. Voltage Protection Yes (32VDC) N/A
DC Input
4-32V DC 50A RSSDN-50A Current (continuous) 10A 25A 50A 75A 90A
75A RSSDN-75A 1-Cycle Surge Current 150A 300A 750A 1000A 1200A
90A RSSDN-90A 1-Second Surge Current 30A 75A 150A 225A 300A
Minimum Holding Current 50mA 50mA 100mA 100mA 100mA
Contactors

Voltage Drop at Rated Current 1.6V (maximum)


Output Specifications

Voltage Range 48 - 660V AC


Output Dual SCR (N.O.)
Over Voltage Rating 1200 PIV
Frequency Range 47 to 80Hz
Off-State Leakage at Rated Voltage 20mA (maximum)
Turn-On Time 1/2 cycle @ 60Hz
Terminal Blocks

Turn-Off Time 1/2 cycle @ 60Hz


Zero Voltage Switching Yes
Static DV/DT 200V/sec
Commutating DV/DT Snubbed for 0.5 power factor at rated load
Weight 10g (approx.)
Circuit Breakers

822 www.IDEC.com
Relays & Sockets RSS

Recommended Loads

Switches & Pilot Lights


Transformer Loads
Transformer loads sometimes result in severe inrush current when the transformer saturates during the first cycle. Use a relay rated for this surge, which has a 1/2
cycle surge current greater than the maximum applied line voltage; the transformers primary resistance (approximately 10x rated current).

Recommended Loads
SSR Rating at 120V AC at 240V AC
10A 500VA 1KVA

Signaling Lights
25A 1KVA 2KVA
50A 2KVA 4KVA

Heater Loads
When using solid state relays for driving heaters where the load is switched on and off rapidly and continuously, severe thermal stress will result. In such cases, use
an SSR relay at no more than 75% of the rating.

Relays & Sockets


Recommended Loads
SSR Rating at 120V AC at 240V AC
10A 1KW 2KW
25A 2KW 4KW
50A 3KW 6KW

Solenoid Valves and Contactors

Timers
RSS relays use high-noise immunity circuitry with a built-in snubber to handle the electrical noise generated by inductive loads.

Recommended Loads

SSR Rating at 120V AC at 240V AC


10A 900W 1,800W
25A 2,100W 4,200W

Contactors
50A 3,800W 7,500W

RSS series relays provide a highly reliable means of switching AC loads when applied properly. Read the technical notes on the following page prior to installing
solid state relays.

Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 823


Switches & Pilot Lights RSS Relays & Sockets

UL Motor Load Ratings (HP Ratings)


Part Number 120V 240V 480V
10A 1/2 3/4 3/4
25A 1/2 3/4 3/4
50A 3/4 1 1/2 1 1/2
75A 3/4 5 5
90A 3/4 5 5
Signaling Lights

Lamp Loads
Zero voltage switching is ideal for driving incandescent lamps, since the cold filament will not be subjected to a large inrush current. Using a zero-switched SSR will
reduce inrush current and prolong lamp life.

Recommended Loads
SSR Rating at 120V AC at 240V AC
Relays & Sockets

10A 1KW 2KW


25A 2KW 4KW
50A 3KW 6KW

Internal Circuit Block Diagram


Timers
Contactors
Terminal Blocks
Circuit Breakers

824 www.IDEC.com
Relays & Sockets RSS

Technical Notes

Switches & Pilot Lights


Environment
Do not install SSRs near sources of excessive heat. Make sure applications are dry and well ventilated.

If SSRs must be installed in an environment subject to high temperatures or poor ventilation, or if SSRs are mounted collectively, reduce the load current so that it
does not approach the ambient temperature-load current recommendation. (See the Temperature Derating Curves on the following page.)

When SSRs are used with inductive loads, suppress the inrush current to half of the peak surge current.

Heat Sinks

Signaling Lights
Heat sinks are recommended for all solid state relays depending on ambient temperature and mounting position. The recommended heat sink dimensions and mate-
rial are shown in the table:

Output Rating Dimensions Material


10A 12 x 12 x 1/8 Aluminum (black anodized)
25A 12 x 12 x 1/8 (DC/AC) Aluminum (black anodized)
25A 15 x 15 x 1/8 (AC/AC) Aluminum (black anodized)

Relays & Sockets


50A 15 x 15 x 1/8 Aluminum (black anodized)
75A 17 x 17 x 1/8 Aluminum (black anodized)
90A 17 x 17 x 1/8 Aluminum (black anodized)

Using a thermal compound between the base of the SSR and the heat sink for heat dissipation is recommended.

Wiring
Locate SSRs as far from motor leads as possible to prevent malfunction from induced current.

Use shielded wires for input leads when they are exposed to a source of induced current.

Timers
Mounting
Provide sufficient ventilation.

Use #6 32 screws, flat washers, and lock washers to secure mounting on heat sinks.

Vertical mounting is recommended to allow air to flow unimpeded. Horizontal or inverted mounting is possible, but the SSR must be derated according to the derating
curves on the following page.

Contactors
Additional Information
Do not exceed the load voltage and current specifications.

A small-capacity load may not turn off due to the leakage current present after the SSR has turned off. If this is the case, use a resistor in parallel with the load to
shunt the leakage current.

Observe the polarity of input terminals. Failure to do so may cause damage to the SSR.

When the SSR output is subjected to a higher than rated voltage, a varistor or other element should be connected to the output terminals to absorb the over-voltage. Terminal Blocks
When the input signal contains a ripple voltage, the lowest ripple amplitude should exceed the minimum pick-up voltage of 4V.

Over 4V
Lowest Voltage
0V
Circuit Breakers

800-262-IDEC (4332) USA & Canada 825


RSS Relays & Sockets

Temperature Derating Curves: RSS Series


Switches & Pilot Lights

10 AMP SCR OUTPUT 25 AMP SCR OUTPUT


Load Current (Amperes)

Load Current (Amperes)


1
Signaling Lights

Ambient Temperature (C) Ambient Temperature (C)


Relays & Sockets

50 AMP SCR OUTPUT 75 AMP SCR OUTPUT


Load Current (Amperes)

Load Current (Amperes)

0.5C/W
0.7C/W
1.0C/W
1.5C/W
Timers
Contactors

Ambient Temperature (C) Ambient Temperature (C)

90 AMP SCR OUTPUT


Terminal Blocks

Load Current (Amperes)


Circuit Breakers

Ambient Temperature (C)

826 www.IDEC.com
Relays & Sockets RSS

Dimensions (mm)

Switches & Pilot Lights


8-32 Pan Head Screw 1.9" (48.26mm)
Large Saddle Clamp
1.75" (44.5mm)
0.187"
1.1" (27.9mm) (4.5mm)

1 2

1.88" (47.6mm)

2.65" (67.31mm)
2.25" (57.2mm)

1.7" (43.2mm)

Signaling Lights
2.4" (6.96mm)
-4 3+

0.2"
1.0" (25.4mm) (4.8mm)
6-32 Pan Head Screw
Small Saddle Clamp

Relays & Sockets


RSS-CVR - Optional Fingersafe Cover
R 0.265" (6.7mm)
0.79"
1.075" (20.07mm)
(27.31mm)
0.95" (24.1mm)

0.5" (12.70mm)
0.09" (2.3mm)
0.37" (9.40mm)

Timers
Contactors
Terminal Blocks
Circuit Breakers

800-262-IDEC (4332) USA & Canada 827


Circuit Breakers Terminal Blocks Contactors Timers Relays & Sockets Signaling Lights Switches & Pilot Lights

828
www.IDEC.com
Relays & Sockets

You might also like