Rexroth 4WS2EM 10... XN... - 114 Servo Valve Re29583 - 2007-04

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.

com

1/12

RE 29583-XN-114-B2/04.07
3/3 servo directional control valve Replaces: 10.04
with mechanical position feedback

Type 4WS2EM 10...XN...-114

Nominal size 10
Unit series 5X
Maximum operating pressure 315 bar
Maximum flow rate 180 l/min
H5893

ATEX units
For potentially explosive atmospheres

Part II Technical Data Sheet


Information on explosion protection:
Range of application in accordance with the
Explosion Protection Directive and type of protection to
EN 50014:1997+A1+A2
Range of application as per Directive RL 94/9/EG
II3G: Type of protection EEx nA II T5 to EN 50021:1999
II3D: Degree of protection IP 65, T100 C to
EN 50281-1-1:1998+A1
Ambient temperature range 30 C Ta +70 C

What you need to know about these Operating Instructions

These Operating Instructions apply to the explosion-proof version of Rexroth valves,


and consist of the following three parts:
Part I General Information RE 07010-X-B1
Part II Technical Data Sheet RE 29583-XN-114-B2 Mat.-Nr. R901034629
Part III Product-specific Instructions RE 29583-XN-114-B3
You can find further information on the correct handling of Rexroth hydraulic products in our publication
General Product Information for Hydraulic Products, RE 07008.
2/12 Bosch Rexroth AG Hydraulics 4WS2EM 10...XN...-114 RE 29583-XN-114-B2

Overview of Contents
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Contents Page
Features 2
Ordering data and scope of delivery 3
Symbol 3
Function, sectional diagram 4
Technical data 5 and 6
Information on explosion protection 6
External trigger electronics 6
Plug-in connector 6
Electrical connection 6
Characteristic curves 7 to 10
Unit dimensions 11
Flushing plate 12

Features
Servo directional control valve for proper use in potentially
explosive atmospheres of Zones 2 and 22
Valve for closed-loop position, draft, pressure and velocity
control
2-Stage servo valve in 3-way version with mechanical
feedback
1st stage in the form of flapper nozzle amplifier
For subplate mounting,
Mounting hole configuration to ISO 4401-05-05-0-05
with ports X and Y.
Subplates as per Technical Data Sheet
RE 45054 (order separately)
Dry servo motor, no contamination of solenoid gaps by
pressure fluid
Non-wearing piston return element
Actuation:
External trigger electronics in Eurocard format or in modular
form (order separately), see page 6
Valve is calibrated and tested
Internal/external control oil supply and return individually
orderable
Piston with flow force compensation
Control sleeve permanently centered, therefore reducing
sensitivity to temperature and pressure
Pressure chambers in the control bush have gap seals,
so there is no O-ring wear
Filter for 1st stage freely accessible from the outside
RE 29583-XN-114-B2 4WS2EM 10...XN...-114 Hydraulics Bosch Rexroth AG 3/12

Ordering data and scope of delivery


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

4WS2E M 10 5X B 11 XN K31 V 114


Electrically operated 114 = Non-standard
2-stage servo valve, version number 6)
3/3-way version Seal material
for external V= FKM seals
trigger electronics
suitable for mineral oil
Mechanical feedback =M (HL, HLP)
Nominal size 10 = 10 to DIN 51524

Unit series 50 to 59 = 5X Piston overlap 5)


(50 to 59: installation and E= 0 0,5 % negative
connection dimensions unchanged) D= 0 0,5 % positive
C= 3 5 % positive
Nominal flow 1)
Electrical connection
5 l/min =5
K31 = with plug
10 l/min = 10
to EN175201-804
20 l/min = 20
30 l/min = 30 Plug-in connector order separately
45 l/min = 45 see Page 6
60 l/min = 60 Supply pressure range to 1st stage 4)
75 l/min = 75 210 = 10 to 210 bar
90 l/min = 90 315 = 10 to 315 bar
Valve for external trigger electronics Control oil supply and discharge 3)
Coil No. 11 (30 mA/85 per coil) 2) = 11
= External supply, external return
E = Internal supply, external return
T = External supply, internal return
Included in scope of delivery:: ET = Internals supply, internal return
Valve fastening screws (ET = Standard version)
Valve operating instructions with Declaration of Conformity in XN = Valve in explosion-proof design
Part III For details, see information on explosion protection,
page 6

1) Nominal flow rate Note:


The nominal flow rate is based on a 100 % setpoint signal Ports X and Y are also subject to pressure when the
at a valve pressure differential of 35 bar per metering notch. supply and return of control oil are internal.
The valve pressure differential should be regarded as a 4) Supply pressure range
guide. The flow rate can be affected by other values.
The system pressure should be kept as constant as possible.
A possible nominal flow tolerance of 10 % (see flow signal
Pilot pressure range: 10 210 bar or 10 315 bar.
function on page 7) must be taken into consideration.
With regard to the dynamics, the dependence on the
2) External trigger electronics frequency response must be taken into account within the
The control signal must be generated by a current-regulated permitted pressure range.
output stage with superimposed dither signal. For trigger 5) Piston overlap
electronics (servo amplifiers), see page 6.
The piston overlap is stated in % of the control piston stroke.
3) Control oil 6) Non-standard version number 114
The pilot pressure should be kept as constant as possible.
Duct B T is 10% open when not actuated (de energized)
Therefore, external pilot control via port X can be advanta-
of the nominal volume. Port A is always closed in the control
geous. The valve may be operated with higher pressure at
range.
X than at P, to increase the dynamics.

Symbol

A B

a, b
P T
4/12 Bosch Rexroth AG Hydraulics 4WS2EM 10...XN...-114 RE 29583-XN-114-B2

Function, sectional diagram


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

4WS2EM 10-5X/...XN...-114
Valves of this type are electrically operated, 2-stage servo The control piston is connected to the flapper plate or the
directional control valves with a mounting hole configuration torque motor by a torsion spring (mechanical return) (9). The
to ISO 4401-05-05-0-05. They are predominantly employed for position of the piston continues to change until the return
closed-loop position, draft, pressure and velocity control. torque through the torsion spring and the electro-magnetic
These valves consist of an electro-mechanical governor (torque torque of the torque motor reach a state of equilibrium, and the
motor) (1), a hydraulic amplifier (flapper jet principle) (2) and a pressure differential at the flapper jet system becomes zero.
control piston (3) in a sleeve (2nd stage), which is connected In this way, the stroke of the control piston and thus the flow of
to the torque motor via a mechanical return. the servo valve is closed loop controlled proportionately to the
An electric input signal at the coils (4) of the torque motor electrical input signal. At the same time, it should be noted that
causes a permanent magnet to generate a force that acts on the flow is dependent on the drop in valve pressure.
the armature (5) and, acting by means of a torque tube (6), this
force generates a torque. This torque then moves the flapper External trigger electronics (order separately)
plate (7) which is connected to the torque tube (6) by a rod The valve is actuated by external trigger electronics (a servo
out of its center position between the two control orifices (8), amplifier), which amplifies an analog input signal (setpoint) so
resulting in a pressure differential at the end faces of the con- that the controlled current output signal is capable of driving
trol piston (3). This pressure differential causes the position of the servo valve.
the piston to change, so that the pressure port is connected to
one consumer port and, at the same time, the other consumer
port is connected to the return port.
In this special version 114, consumer port A is closed.

Type 4WS2EM 10XN-114


1
4
5

6
2
7

3
T P T1
A B
RE 29583-XN-114-B2 4WS2EM 10...XN...-114 Hydraulics Bosch Rexroth AG 5/12

Technical data
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

General
Mounting hole configuration ISO 4401-05-05-0-05
Installation position Optional (provided that the pilot control is certain to receive
sufficient pressure ( 10 bar) when starting up the
system!)
Surface protection Valve body, cover, filter screw Nitrocarburized
Cap Anodized
Storage temperature range C 20 +80
Ambient temperature range C 30 +70
Weight kg 3.56

Hydraulic (measured with HLP 32, oil = 40 C 5 C)


Working Control oil supply pilot stage bar 10 210 or 10 315
pressure: Main valve, ports P, A, B bar up to 315
Return pressure: Port T
Internal control oil return bar Pressure peaks < 100 permitted
External control oil return bar up to 315
Port Y bar Pressure peaks < 100 permitted, static < 10
Pressure fluid Mineral oil (HL, HLP) to DIN 51524
ignition temperature > 150 C
Pressure fluid temperature range C 15 +80, preferably +40 +50
Viscosity range mm2/s 15 380, preferably 30 45
Maximum permissible degree of contamination of
pressure fluid Purity class to ISO 4406 (c) Class 18/16/13 1)
2)
Zero flow qV,L pP 4) l pP 4) l pP 4) l pP 4) l pP 4) l
l/min 0.6 0.7 0.9 1.1 1.3
with piston overlap E 70bar min 70bar min 70bar min 70bar min 70bar min
measured without dither signal
Nominal flows qv nom 3), Tolerance 10 %
at valve pressure differentia p = 35 bar per edge l/min 5 10 20 30 45 60 75 90
Max. possible control piston stroke based on mechanical
end position (in case of fault) referred to nominal stroke % 120 170 120 150
Return system Mechanical
Hysteresis (dither optimized) % 1.5
Range of inversion (dither optimized) % 0.2
Response sensitivity (dither optimized) % 0.2
Pressure gain with 1 % piston stroke variation
(starting from hydraulic zero) % of pP 4) 30
Zero adjustment flow over entire working
pressure range % 3, long-term 5
Zero offset on variation of:
Pressure fluid temperature % / 20 K 1
Ambient temperature % / 20 K 1
Working pressure 80 120 % of pP 4) % / 100 bar 2
Return pressure 0 10 % of pP 4) % / bar 1

1) 2) qV,L = zero flow in l/min


The purity classes stated for the components must be com-
plied with in hydraulic systems. Effective filtration prevents 3) qv nom = nominal flow in l/min
problems and also extends the service life of components. 4) pP = working pressure in bar
For a selection of filters, see Technical Data Sheets
RE 50070, RE 50076 and RE 50081.
6/12 Bosch Rexroth AG Hydraulics 4WS2EM 10...XN...-114 RE 29583-XN-114-B2

Technical data
Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Electrical
Degree of protection to EN 60529:1991+A1:2000 IP 65 with correctly mounted and locked plug-in connector
Type of signal Analog
Nominal current per coil mA 30
Resistance per coil 85
Inductivity at 60 Hz Series connection H 1.0
and 100 % nominal current Parallel connection H 0.25
Necessary superimposed dither signal when actuating with Amplitude depending on hydraulic system:
non-Rexroth amplifiers: f = 400 Hz max. 3 % of nominal current

Information on explosion protection


Range of application to Directive RL 94/9/EG II 3 G; II 3 D
Type of protection to EN 50014:1997+A1+A2 / EN 50021:1999 EEx nA IIT5
Type of protection and temperature to EN 50281-1-1:1998+A1 IP 65, T100 C
Ambient temperature range C 30 +70
Pressure fluid temperature range C 15 +80
Max. permitted operating voltage of servo amplifier V 32

External trigger electronics


Servo amplifier Eurocard format Analog Type VT-SR2-1X/.60 as per Technical Data Sheet RE 29980
(order separately) Modular design Analog Type VT 11021 as per Technical Data Sheet RE 29743
The valve coils should only be connected to this amplifier in parallel!
WARNING risk of explosion
The external servo amplifier must be operated outside the potentially explosive atmosphere!

Plug-in connector
Electrical connection
EN 175201-804
A
B F Metal version
Order separately under
C E
D Material No. R901044595
813,5

Connection:
Soldered contacts with
85 conductor cross-section
for wires 0.5 1.5 mm2
Retaining screw

Electrical connection (Example of parallel connection)


Non-potentially explosive Potentially explosive The coils are connected in parallel in the plug-in connector or
atmosphere atmosphere Valve: Coil to the amplifier (see figure).
Trigger electronics Plug-in connector A B In the case of a serial connection, connect contacts B and C.
A The bridge E-F can be used for electrically recognizing that
C the plug is correctly connected or for detecting open circuits.
Electrical actuation from A (+) to D () results in a flow
B
direction of B T. Reversing electrical actuation produces
D
a flow direction of P B.
E
F
RE 29583-XN-114-B2 4WS2EM 10...XN...-114 Hydraulics Bosch Rexroth AG 7/12

Characteristic curves (measured with HLP 32, oil = 40 C 5 C)


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Flow load function (tolerance 10 %) with 100 % setpoint signal


Note:
Observe flow values in the max. setpoint range (see tolerance zone of flow signal function)

200 8
Order Nominal flow Cur-
7
code ve
6
100 5 5 l/min 1
90 5
75 10 10 l/min 2
70
60 4
50 20 20 l/min 3
45
40 3 30 30 l/min 4
30
Flow rate in l/min

45 45 l/min 5
20 2 60 60 l/min 6
15 75 75 l/min 7

10 90 90 l/min 8
1
8
p = valve pressure differential
5 (inlet pressure pP minus
load pressure pL and
minus return pressure pT)

1
5 10 15 20 25 30 35 50 100 150
Metering edge pressure differential in bar for P B or B T

Tolerance zone of flow signal function with constant valve pressure differential p

BT
110
100
Flow rate in %
80

60

40

20 Tolerance zone
-100 -80 -60 -40 -20 -10

Typical flow 20 40 60 80 100


curve 20 Setpoint in %

40

60

80

100
110
PB
8/12 Bosch Rexroth AG Hydraulics 4WS2EM 10...XN...-114 RE 29583-XN-114-B2

Characteristic curves (measured with HLP 32, oil = 40 C 5 C)


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Transient function with 315 bar pressure stage, step response without flow
Nominal flow 5, 10, 20 l/min Nominal flow 30 l/min
100 100
90 90
80 80
Piston stroke in %

Piston stroke in %
70 70
60 60
50 50
40 40
30 30
20 20
10 10

0 10 20 30 40 0 10 20 30 40
Time in ms Time in ms
40 bar 70 bar 140 bar 210 bar 315 bar

Frequency response with 315 bar pressure stage, stroke frequency response without flow
Nominal flow 5, 10, 20 l/min Nominal flow 30 l/min
5 315 5 315
Amplitude relationship in dB

Amplitude relationship in dB

0 270 0 270
3 3
Phase angle in

Phase angle in
5 225 5 225

10 180 10 180

15 135 15 135

20 90 20 90

25 45 25 45

30 0 30 0
10 20 50 100 200 500 700 10 20 50 100 200 500 700
Frequency in Hz Frequency in Hz
5 % XeN 25 % XeN 100 % XeN

Relationship of frequency f at 90 to working pressure p and input amplitude


Nominal flow 5, 10, 20 l/min Nominal flow 30 l/min
100 100
90 90
Input amplitude in %

Input amplitude in %

80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 50 100 150 200 250 300 325 0 50 100 150 200 250 300 325
Frequency at phase angle 90 in Hz Frequency at phase angle 90 in Hz
40 bar 70 bar 140 bar 210 bar 315 bar
RE 29583-XN-114-B2 4WS2EM 10...XN...-114 Hydraulics Bosch Rexroth AG 9/12

Characteristic curves (measured with HLP 32, oil = 40 C 5 C)


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Transient functions with 315 bar pressure stage, step response without flow
Nominal flow 45 l/min Nominal flow 60 l/min
100 100
90 90
80 80
Piston stroke in %

Piston stroke in %
70 70
60 60
50 50
40 40
30 30
20 20
10 10

0 10 20 30 40 0 10 20 30 40
Time in ms Time in ms
40 bar 70 bar 140 bar 210 bar 315 bar

Frequency response with 315 bar pressure stage, stroke frequency response without flow
Nominal flow 45 l/min Nominal flow 60 l/min
5 5
Amplitude relationship in dB

Amplitude relationship in dB

0 0
3 3
Phase angle in

Phase angle in
5 5

10 10
150 150
15 15
120 120
20 90 20 90
60 60
25 25
30 30
30 0 30 0
2 10 20 50 100 200 300 700 2 10 20 50 100 200 300 700
Frequency in Hz Frequency in Hz
5 % XeN 25 % XeN 100 % XeN

Relationship of frequency f at 90 to working pressure p and input amplitude


Nominal flow 45 l/min Nominal flow 60 l/min
100 100
90 90
Input amplitude in %

Input amplitude in %

80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 50 100 150 200 250 300 325 0 50 100 150 200 250 300 325
Frequency at phase angle 90 in Hz Frequency at phase angle 90 in Hz
40 bar 70 bar 140 bar 210 bar 315 bar
10/12 Bosch Rexroth AG Hydraulics 4WS2EM 10...XN...-114 RE 29583-XN-114-B2

Characteristic curves (measured with HLP 32, oil = 40 C 5 C)


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

Transient functions with 315 bar pressure stage, step response without flow
Nominal flow 75 l/min Nominal flow 90 l/min
100 100
90 90
80 80
Piston stroke in %

Piston stroke in %
70 70
60 60
50 50
40 40
30 30
20 20
10 10

0 10 20 30 40 0 10 20 30 40
Time in ms Time in ms
40 bar 70 bar 140 bar 210 bar 315 bar

Frequency response with 315 bar pressure stage, stroke frequency response without flow
Nominal flow 75 l/min Nominal flow 90 l/min
5 5
Amplitude relationship in dB

Amplitude relationship in dB

0 0
3 3
Phase angle in

Phase angle in
5 5

10 10
150 150
15 15
120 120
20 90 20 90
60 60
25 25
30 30
30 0 30 0
2 10 20 50 100 200 300 700 2 10 20 50 100 200 300 700
Frequency in Hz Frequency in Hz
5 % XeN 25 % XeN 100 % XeN

Relationship of frequency f at 90 to working pressure p and input amplitude


Nominal flow 75 l/min Nominal flow 90 l/min
100 100
90 90
Input amplitude in %

Input amplitude in %

80 80
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 50 100 150 200 250 300 325 0 50 100 150 200 250 300 325

Frequency at phase angle 90 in Hz Frequency at phase angle 90 in Hz


40 bar 70 bar 140 bar 210 bar 315 bar
RE 29583-XN-114-B2 4WS2EM 10...XN...-114 Hydraulics Bosch Rexroth AG 11/12

Unit dimensions (Nominal dimensions in mm)


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

3 2 1
15 95 68

32
96
0,01/100mm
80

64
Rzmax 4

60
Required surface quality
of valve bearing

10
9,5

M6

10 4 6 7 5 8 9

3,7
25,5

11
9,5

P
F1 P F2
X A B Y X Y
46

A B

68
65

T T1
T T1 F4 F3
105
1,5

12,5 24 54
102
127

1 Cap 10 Valve fastening bolts


2 Plug-in connector In order to ensure a secure connection, use only the
(order separately, see Page 6) following valve fastening bolts:
4 cheese-head bolts
3 Required space for removing plug-in connector, note
ISO 4762-M6x70-10.9-flZn-240h-L
additional bending radius of connecting cable
(coefficient of friction 0.09 - 0.14 to VDA 235-101)
4 Replaceable filter element (included in scope of delivery)
Material No.: R900306843
5 Formed gasket for filter screw M16 x 1.5 Subplates as per Technical Data Sheet RE 45054 must be
Material No.: R900012503 (FKM seal) ordered separately.
6 Nameplate G 66/01 (G3/8)
7 Same seals for ports P, A, B, T and T1 G 67/01 (G1/2)
8 Same seals for ports X and Y with ports X and Y:
Ports X and Yare also pressurized when the control oil G 535/01 (G3/4)
supply and return are internal. G 535/02 (M27 x 2)
9 Machined valve contact surface G 536/01 (G1)
Position of ports as per ISO 4401-05-05-0-05 G 536/02 (M33 x 2)
Port T1 is optional and is recommended for reducing the
pressure difference from B T.
12/12 Bosch Rexroth AG Hydraulics 4WS2EM 10...XN...-114 RE 29583-XN-114-B2

Flushing plate with mounting hole configuration to ISO 4401-05-05-0-05


Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com

(Nominal dimensions in mm)

Symbol
T P X A B Y T1

Ordering data and further information

46,5
Material No.: R900912450

40,5
Weight: 2 kg
Same seals for ports P, A, B, T and T1
Same seals for ports X and Y

9,5
Fastening bolts
In order to ensure a secure connection, use only the
following fastening bolts:
4 cheese-head bolts
ISO 4762-M6x50-10.9-flZn-240h-L
(coefficient of friction 0.09 - 0.14 to VDA 235-101)
(included in scope of delivery)

Hinweis
Before assembly, please read the notes in the Product-specific
Instructions RE 29583-XN-114-B3, section 3.2.

Bosch Rexroth AG This document, as well as the data, specifications and other information
Hydraulics set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengieer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No state-
Telefon +49 (0) 93 52 / 18-0 ments concerning a certain condition or suitability for a certain application
Telefax +49 (0) 93 52 / 18-23 58 can be derived from our information. The information given does not release
[email protected] the user from the obligation of own judgment and verification. It must be
www.boschrexroth.de remembered that our products are subject to a natural process of wear and
aging.

You might also like