SLVA812
SLVA812
SLVA812
1
2
3
Contents
Background ................................................................................................................... 1
Operation ..................................................................................................................... 2
Summary ...................................................................................................................... 6
List of Figures
Automatic ICO detection after increase in charge current with V(BAT) > VMINSYS ............................... 3
Automatic ICO detection after increase in charge current with V(BAT) < VMINSYS ............................... 4
Background
Wall adapters used to power portable electronic devices come in a variety of voltage and current ratings.
Most battery chargers inside the portable devices include one or more fast response feedback control
loops to prevent the charger from pulling too much current from their wall adapter, thereby collapsing it.
One such loop is the input current limit dynamic power management (IINDPM) loop. The designer,
through external resistor, I2C register, or the chargers D+/D- circuitry automatically sets a predetermined
value for the amount of input current the charger is allowed to pull from the adapter. The chargers
dynamic power path management circuitry then distributes this input power to the system load and
uncharged battery, reducing charge current if necessary to provide the demanded dc or transient system
load. In the event the adapter cannot provide its rated output current or because of highly resistive
connections from the source to the charger, the chargers input pin voltage droops. This could also
happen when an adapter unknown to D+/D- detection (for example, a 3rd party adapter) is attached and
the charger sets the IINDPM setting too high. When this happens, the second feedback loop, input voltage
input dynamic power management or VINDPM, activates and reduces the charge current to prevent the
charger from crashing the adapter as highlighted in Figure 1.
Operation
www.ti.com
VBUS
IINLIM
VADPTR
VINDPMTH
VINDPM_ILIM
Operation
If the bq2589x EN_ILIM bit (REG00[6]) is set, then the actual input current limit is the lower of the value
set by the ILIM pin resistor or as reported by the IDPM_ILIM registers (in other words, the ILIM pin resistor
clamps the maximum input current limit value). The remainder of the application note assumes EN_ILIM =
0 which results in the IDPM_ILIM reporting the actual input current limit in use.
With ICO disabled (REG02[4] = 0) or until the ICO algorithm has optimized the input current limit, the
ICO_OPTIMIZED bit (REG14[6]) = 0 indicating optimization is disabled or in progress. The IDPM_ILIM
register (REG13[0:5]) reports the same value as configured in the IINLIM register (REG00[0:5]) by the
D+/D- algorithm (bq25890, bq25895) or PSEL bit (bq25892, bq25896) at startup, or by host software.
If ICO is enabled, the charger waits for the first VINDPM event to occur, in other words for the desired
output power to exceed the allowed input power. When V(BAT) > VMINSYS, the ICO algorithm does the
following:
Reduces IDPM_LIM to 500 mA then
steps up the current limit until the input voltage drops to VINDPM threshold then
lowers the IDPM_ILIM register slightly below the point where VINDPM is reached.
The ICO_OPTIMIZED bit is set to 1.
Operation
www.ti.com
Figure 2 is a graphical representation of the ICO algorithm list above. It is assumed that the system load
or charge current increases at the point where the VBUS voltage is no longer at the adapter voltage
(VADPTR).
VBUS
IINLIM
VADPTR
VINDPMTH
I
500mA
IDPM_ILIM
VINDPM_ILIM
Figure 3. Automatic ICO detection after increase in charge current with V(BAT) > VMINSYS
Operation
www.ti.com
In order to ensure that the system has enough power when V(BAT) < VMINSYS, the ICO algorithm works
simpler by:
setting the input current equal to the IINLIM register value (which is clamped to a lower value by the
VINDPM control loop), then
stepping down the current limit until the charger exits VINDPM control.
The IDPM_ILIM register is updated to this input current limit value and
the ICO_OPTIMIZED bit is set to 1.
Figure 4 is scope shot of this on the same board but with a V(BAT) < VMINSYS.
Figure 4. Automatic ICO detection after increase in charge current with V(BAT) < VMINSYS
Operation
www.ti.com
The input current limit remains optimized and will not automatically run the ICO detection algorithm again
unless the following occurs:
another VINDPM event or
IINLIM register changes or
VINDPM_OS register (when FORCE_VINDPM=0) changes or
VINDPM register (when FORCE_VINDPM=1) changes
In addition, for the bq25890/5x parts with D+/D-, if DCP/HVDCP adapter is detected at startup, the ICO
algorithm automatically runs.
The host software can also force ICO detection using the FORCE_ICO bit (REG09[7]) or toggling the
ENable_ICO ( REG02[4]) bit, which defaults to 1. As shown in Figure 5, when forcing detection, the ICO
detection algorithm first disables charge for 10 ms and applies a 10 mA sink on BAT, in order to determine
whether V(BAT) is greater than or equal to VMINSYS, and then precedes as previously described.
Summary
www.ti.com
Summary
A charges VINDPM loop is the last line of defense in preventing the charger from collapsing its input
source, i.e. adapter. While the charger is fully capable of indefinitely regulating its input current limit using
the VINDPM loop, running a wall adapter in an overload state is unhealthy for the adapter. The designer
sets the input current limit register, either through external ILIM resistor or IINLIM register to match the
adapters rated current. In the event of malfunctioning adapters or highly resistive adapter cables, the
bq2589x ICO circuitry finds the charger optimal input current limit setting for maximum power extraction
without adapter overload. The Table 1 summarizes possible cases for input current limit registers.
Table 1. Current Limit Registers
TEST CONDITIONS
Adapter
INLIM Register
RESULTS
ICHG Register
IDPM_LIM
Register
ICO Status
Register
Actual Input
Current Limit
3.25 A
2 A clamped by
ILIM resistor
1.5 A
2A
2 A clamped to
INLIM
3.25 A
0 ICHG doesnt
require 3.25 A input
3.25 A
Case 1
5 V at 3 A
2A
3.25 A
5A
Case 2
5 V at 1.5 A
2A
3.25 A
5A
Case 3
5 V at 3 A
3A
2A
5A
Case 4
5 V at 3 A
3A
3.25 A
2A
IMPORTANT NOTICE
Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, enhancements, improvements and other
changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest
issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and
complete. All semiconductor products (also referred to herein as components) are sold subject to TIs terms and conditions of sale
supplied at the time of order acknowledgment.
TI warrants performance of its components to the specifications applicable at the time of sale, in accordance with the warranty in TIs terms
and conditions of sale of semiconductor products. Testing and other quality control techniques are used to the extent TI deems necessary
to support this warranty. Except where mandated by applicable law, testing of all parameters of each component is not necessarily
performed.
TI assumes no liability for applications assistance or the design of Buyers products. Buyers are responsible for their products and
applications using TI components. To minimize the risks associated with Buyers products and applications, Buyers should provide
adequate design and operating safeguards.
TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or
other intellectual property right relating to any combination, machine, or process in which TI components or services are used. Information
published by TI regarding third-party products or services does not constitute a license to use such products or services or a warranty or
endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the
third party, or a license from TI under the patents or other intellectual property of TI.
Reproduction of significant portions of TI information in TI data books or data sheets is permissible only if reproduction is without alteration
and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such altered
documentation. Information of third parties may be subject to additional restrictions.
Resale of TI components or services with statements different from or beyond the parameters stated by TI for that component or service
voids all express and any implied warranties for the associated TI component or service and is an unfair and deceptive business practice.
TI is not responsible or liable for any such statements.
Buyer acknowledges and agrees that it is solely responsible for compliance with all legal, regulatory and safety-related requirements
concerning its products, and any use of TI components in its applications, notwithstanding any applications-related information or support
that may be provided by TI. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which
anticipate dangerous consequences of failures, monitor failures and their consequences, lessen the likelihood of failures that might cause
harm and take appropriate remedial actions. Buyer will fully indemnify TI and its representatives against any damages arising out of the use
of any TI components in safety-critical applications.
In some cases, TI components may be promoted specifically to facilitate safety-related applications. With such components, TIs goal is to
help enable customers to design and create their own end-product solutions that meet applicable functional safety standards and
requirements. Nonetheless, such components are subject to these terms.
No TI components are authorized for use in FDA Class III (or similar life-critical medical equipment) unless authorized officers of the parties
have executed a special agreement specifically governing such use.
Only those TI components which TI has specifically designated as military grade or enhanced plastic are designed and intended for use in
military/aerospace applications or environments. Buyer acknowledges and agrees that any military or aerospace use of TI components
which have not been so designated is solely at the Buyer's risk, and that Buyer is solely responsible for compliance with all legal and
regulatory requirements in connection with such use.
TI has specifically designated certain components as meeting ISO/TS16949 requirements, mainly for automotive use. In any case of use of
non-designated products, TI will not be responsible for any failure to meet ISO/TS16949.
Products
Applications
Audio
www.ti.com/audio
www.ti.com/automotive
Amplifiers
amplifier.ti.com
www.ti.com/communications
Data Converters
dataconverter.ti.com
www.ti.com/computers
DLP Products
www.dlp.com
Consumer Electronics
www.ti.com/consumer-apps
DSP
dsp.ti.com
www.ti.com/energy
www.ti.com/clocks
Industrial
www.ti.com/industrial
Interface
interface.ti.com
Medical
www.ti.com/medical
Logic
logic.ti.com
Security
www.ti.com/security
Power Mgmt
power.ti.com
www.ti.com/space-avionics-defense
Microcontrollers
microcontroller.ti.com
www.ti.com/video
RFID
www.ti-rfid.com
www.ti.com/omap
TI E2E Community
e2e.ti.com
Wireless Connectivity
www.ti.com/wirelessconnectivity
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright 2016, Texas Instruments Incorporated