Altivar Process ATV600 ATV630D11N4
Altivar Process ATV600 ATV630D11N4
Altivar Process ATV600 ATV630D11N4
Characteristics
ATV630D11N4
range of product
product or component
type
ATV630
variant
Standard version
product destination
Synchronous motors
Asynchronous motors
mounting mode
Wall mount
EMC filter
IP degree of protection
degree of protection
type of cooling
Forced convection
supply frequency
50...60 Hz (- 5...5 %)
network number of
phases
3 phases
380...480 V (- 15...10 %)
motor power kW
11 kW (normal duty)
7.5 kW (heavy duty)
motor power hp
15 hp (normal duty)
10 hp (heavy duty)
line current
50 kA
apparent power
asynchronous motor
control profile
output frequency
0.0001...0.5 kHz
4 kHz
switching frequency
safety function
16 preset speeds
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Ethernet
Modbus serial
Modbus TCP
option card
Complementary
output voltage
braking to standstill
By DC injection
protection type
frequency resolution
electrical connection
type of connector
physical interface
transmission frame
transmission rate
exchange mode
data format
type of polarization
number of addresses
method of access
supply
local signalling
width
171 mm
height
409 mm
depth
233 mm
product weight
7.7 kg
input compatibility
STOA, STOB, positive logic (source) : , < 5 V (state 0), > 11 V (state 1)
DI5, DI6, positive logic (source) : , < 0.6 V (state 0), > 2.5 V (state 1)
DI1...DI6, positive logic (source) : , < 5 V (state 0), > 11 V (state 1)
DI1...DI6, negative logic (sink) : , > 16 V (state 0), < 10 V (state 1)
sampling duration
accuracy
linearity error
refresh time
Relay output R1, R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 A at
30 V DC
Relay output R1, R2, R3 on inductive load (cos phi = 0.4 and L/R = 7 ms) : 2 A at
250 V AC
Relay output R1, R2, R3 on resistive load (cos phi = 1) : 3 A at 30 V DC
Relay output R1, R2, R3 on resistive load (cos phi = 1) : 3 A at 250 V AC
isolation
IP degree of protection
IP21
Environment
insulation resistance
noise level
56 dB conforming to 86/188/EEC
power dissipation in W
103.0 m3/h
operating position
THDI
electromagnetic compatibility
pollution degree
vibration resistance
shock resistance
relative humidity
-40...70 C
operating altitude
environmental characteristic
standards
IEC 61508
EN/IEC 61800-3
UL 508C
EN/IEC 61800-3 environment 1 category C2
IEC 13849-1
EN/IEC 61800-3 environment 2 category C3
IEC 60721-3
EN/IEC 61800-5-1
IEC 61000-3-12
product certifications
DNV-GL
CSA
ATEX zone 2/22
TV
REACH
UL
ATEX INERIS
marking
CE
Offer Sustainability
Sustainable offer status
REACh
Product environmental profile
Product end of life instructions
Reference contains SVHC above the threshold - go to CaP for more details
to CaP for more details
Available
Product Environmental
Available
Go
ATV630D11N4
Dimensions
IP21 / UL Type 1 Drives - Front and Left View
ATV630D11N4
Clearances
X1
X2
X3
10 mm (0.39 in.)
Mount the device in a vertical position (10). This is required for cooling the device.
Do not mount the device close to heat sources.
Leave sufficient free space so that the air required for cooling purposes can circulate from the bottom to the top of the drive.
Mounting Types
Mounting Type A: Individual IP21
ATV630D11N4
Single or Three-Phase Power Supply with Upstream Breaking via Line Contactor
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1
(1) Use digital output R1 set to operating state Fault to switch Off the product once an error is detected.
A1 : Drive
KM1 :Line Contactor
Q2, Circuit breakers
Q3 :
S1, Pushbuttons
S2 :
T1 : Transformer for control part
Single or Three-Phase Power Supply with Downstream Breaking via Switch Disconnector
Connection diagrams conforming to standards EN 954-1 category 1 and IEC/EN 61508 capacity SIL1, stopping category 0 in accordance
with standard IEC/EN 60204-1
(1) Use digital output R1 set to operating state Fault to switch Off the product once an error is detected.
A1 : Drive
Q1 : Switch disconnector
Sensor Connection
It is possible to connect either 1 or 3 sensors on terminals AI2 or AI3.
Switch Set to SRC (Source) Position Using the Output Power Supply for the Digital Inputs
Switch Set to SRC (Source) Position and Use of an External Power Supply for the DIs
Switch Set to SK (Sink) Position Using the Output Power Supply for the Digital Inputs
Switch Set to EXT Position Using an External Power Supply for the DIs
10
ATV630D11N4
Derating Curves
11