XQ1000 Lehx0532
XQ1000 Lehx0532
XQ1000 Lehx0532
XQ1000
SOUND ATTENUATED
POWER MODULE
60 Hz
FEATURES
EMISSIONS
EPA and CARB Emissions Certified for non-road
mobile applications.
CAT DIESEL GENERATOR SETS
Factory designed, certified prototype tested with
torsional analysis. Production tested and delivered
to you in a package that is ready to be connected
to your fuel and power lines. Electric Power
Design Pro computer sizing available. Supported
100% by your Caterpillar dealer with warranty on
parts and labor. Extended warranty available in
some areas. The generator set was designed and
manufactured in an ISO 9001 compliant facility.
Generator set and components meet or exceed
the following specifications: AS1359, AS2789,
ABGSM TM3, BS4999, DIN6271, DIN6280,
EGSA101P, JEM1359, IEC 34/1, ISO3046/1,
ISO8528, NEMA MG1-22.
CATERPILLAR SR4B GENERATOR
Single bearing, wye connected, static regulated,
brushless permanent magnet excited generator
designed to match the performance and output
characteristics of the Caterpillar diesel engine
that drives it.
W H E R E
T H E
W O R L D
T U R N S
F O R
P O W E R
R E N T A L
FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT
System
Engine
Generator
Containerized
Module
Cooling
Switchgear
Standard
Optional
SPECIFICATIONS
CAT SR4B GENERATOR
Type . . . . . . Static regulated brushless PM excited
Construction . . . . . . Single bearing, close coupled
Three-phase . . . . . . . . . . . Wye connected 6 lead
Insulation . . . . . . . . . . . Class H 2 extra dips and
bakes on random wound units
Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . Drip proof
Alignment . . . . . . . . . . . . . . . . . . . . . . . . . . . Pilot shaft
Overspeed capability . . . . . . . . . . . . . . . . . . . . . 130%
Voltage regulator . . . . . . . . . . 3-phase sensing with
Volts-per-Hertz
Voltage regulation . . . . . . . . . . . . . . Less than 0.5%
Voltage gain . . . . . . Adjustable to compensate for
engine speed droop and line loss
Wave form . . . . . . . . . . . . . . Less than 5% deviation
TIF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 50
THD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Less than 3%
R E N T A L
TECHNICAL DATA
Power Rating
60 Hz
Standby
1000
ekW
hours
hours
kg (lb)
kg (lb)
Prime
910
3508B
12 (40)
see below
m (ft)
16
33
18
37
18 500 (40,787)
22 585 (49,787)
Container Dimensions
12192.0 [480.00]
R1219.2 [R48.00]
2 Places
2438.4 [96.00]
R963.3 [R37.92]
3 Places
R744.5 [R29.31]
2 Doors Each Side
(Cable Storage Box)
12192.0 [480.00]
7723.5 [304.07]
1877.2 [73.90]
4115.0 [162.01]
The power module must have support under the center when set
on the ground.
Dimensions
Length
Width
Height
12192.0 mm
2438.4 mm
4115.0 mm
480.00 in
96.00 in
162.01 in
R E N T A L
STANDARD CONTROLS
12 m (40 ft) CONTAINERS
480V/60 Hz
ANNUNCIATION CIRCUITS
Upon receipt of an alarm or shutdown
condition, the horn shall sound and an LED
shall flash. Upon acknowledgement from
alarm acknowledge/lamp test switch, the
horn shall be silenced and the lamp
steadied. LED shall be extinguished when
ECS is placed in the off/reset position if the
alarm condition has been corrected.
Circuits are recurring such that the LED
shall flash and the horn sound, should
another fault occur even prior to correction
of the initial fault.
ALARM MODULE
Flashing LED warnings for: low coolant
temperature, high coolant temperature
(pre-alarm), low oil pressure (pre-alarm),
engine control switch not in automatic, and
low DC voltage. Includes alarm horn and
acknowledge pushbutton.
VOLTAGE REGULATOR
Standard Caterpillar generator-mounted
digital voltage regulator with voltage adjust
rheostat mounted in the floorstanding
switchgear.
R E N T A L
STANDARD CONTROLS (Continued)
CURRENT TRANSFORMERS (3)
Five-ampere secondary with shorting
terminal strips
R E N T A L
www.CAT-ElectricPower.com
U.S. sourced
LEHX0532 (10-00)
2000 Caterpillar
All rights reserved.
Printed in U.S.A.
Materials and specifications are subject to change without notice.
The International System of Units (SI) is used in this publication.