Description
3 (16)
Description
Anybus Wireless Bolt provides wireless communication capability over WLAN
and/or Bluetooth to Ethernet, serial and CAN networks.
This document describes how to install Anybus Wireless Bolt and set up a basic
configuration. For additional documentation and technical support, please visit
the Anybus support website www.anybus.com/support.
Installation
Anybus Wireless Bolt should always be mounted vertically (logo facing upwards)
due to the characteristics of the internal antenna.
For optimal reception devices should be placed with a line of sight between them
clear of obstructions. A minimum distance of 50 cm between the devices should
be observed to avoid interference.
Make sure that you have all the necessary information about the capabilities and
restrictions of your local network environment before installing the Anybus Wireless Bolt. Contact your network administrator if in doubt.
Caution
This equipment emits RF energy in the ISM (Industrial, Scientific,
Medical) band. Make sure that all medical devices used in proximity to
this device meet appropriate susceptibility specifications for this type of
RF energy.
SCM-1202-006/SP2139 1.5
Installation
4 (16)
Mechanical Installation
Anybus Wireless Bolt is intended to be mounted on top of a machine or cabinet
through an M50 (50.5 mm) hole using the included sealing ring and nut.
Tightening torque: 5 Nm 10 %
Make sure that the sealing ring is correctly placed in the circular groove
in the top part of the housing before tightening the nut.
SCM-1202-006/SP2139 1.5
Installation
5 (16)
Connector Pinning
Pin
Name
Description
VIN
GND
Power Ground
DI
DI_GND
ETN_RD+
ETN_RD-
ETN_TD-
ETN_TD+
RS485_B
RS-485 B Line
10
FE/Shield
11
RS232_TXD
RS-232 Transmit
12
RS485_A/RS232_RXD
13
RS232_RTS
14
RS232_CTS
15
ISO_5V
16
ISO_GND
17
CAN_L
CAN Low
18
CAN_H
CAN High
SCM-1202-006/SP2139 1.5
Installation
6 (16)
Cabling
To make an Ethernet connector cable for the Anybus Wireless Bolt:
1.
Cut off one of the connectors on a standard Cat5e or Cat6 Ethernet cable.
2.
Strip off about 40 mm (1 inch) of the cable jacket and untwist the orange,
orange/white, green and green/white wires. The other wires will not be used.
3.
4.
Push the pin spring release next to each socket on the connector and insert
the correct wire end according to Connector Pinning, p. 5.
Connect the wires from the power supply to the connector in the same way as
the Ethernet wiring. Make sure that polarity is not reversed.
SCM-1202-006/SP2139 1.5
Configuration
7 (16)
Configuration
Anybus Wireless Bolt can be configured either by setting individual parameters
in the web interface or by using a pre-configured Easy Config mode.
Advanced configuration can be carried out by issuing AT (Hayes) commands in
the AT Commands tab in the web interface, or over Telnet to port 8080. A list of
the supported AT commands is available at www.anybus.com/support.
The web interface is designed for the latest versions of Internet Explorer,
Chrome, Firefox and Safari. Other browsers may not be supported.
SCM-1202-006/SP2139 1.5
Configuration
8 (16)
Role
Description
(reserved)
Client
WLAN AP
Bluetooth NAP
Mode Timeout
If no connection is established within 120 seconds the devices will cancel the
Easy Config modes and return to their initial state.
SCM-1202-006/SP2139 1.5
Configuration
9 (16)
Factory Reset
Anybus Wireless Bolt can be reset to the factory default settings using either of
the following methods:
Press and hold the Reset Button for >10 seconds and then release it
Static
IP Address
192.168.0.99
Subnet Mask
255.255.255.0
Default Gateway
192.168.0.99
WLAN Settings
Operating Mode
Client
Channel Bands
Authentication Mode
Open
Channel
Auto
Bluetooth Settings
Operating Mode
PANU (Client)
Local Name
Security Mode
Disabled
System Settings
Password
[empty]
SCM-1202-006/SP2139 1.5
Configuration
10 (16)
Reset Button
The reset button is located on the bottom of the unit next to the connector.
Press and hold the button for >10 seconds and then release it to reset to the
factory default settings when the unit is powered on.
Press and hold the button during startup to enter Recovery Mode.
Recovery Mode
If the web interface cannot be accessed, the unit may be reset by starting in Recovery Mode and reinstalling the firmware using Anybus Firmware Manager II.
For further instructions, please refer to the manual update wizard in Anybus
Firmware Manager II.
Firmware updates should normally be carried out through the web
interface. Recovery Mode should only be used if the Wireless Bolt is
unresponsive and the web interface cannot be accessed.
SCM-1202-006/SP2139 1.5
Configuration
11 (16)
Configuration Examples
For more configuration examples, see the Anybus Wireless Bolt User Manual
available at www.anybus.com/support.
EXAMPLE 1: Setting up a network bridge with Easy Config
This example describes how to connect two Ethernet network segments over
WLAN or Bluetooth using two Wireless Bolts.
1.
Reset both Wireless Bolts to the factory defaults (see Factory Reset).
2.
On Wireless Bolt 1, execute Easy Config Mode 4. This unit will now be discoverable and open for automatic configuration.
3.
On Wireless Bolt 2, execute either Easy Config Mode 5 for WLAN, or 6 for
Bluetooth. This unit should now automatically discover and configure Wireless Bolt 1 as a WLAN or Bluetooth client.
SCM-1202-006/SP2139 1.5
Configuration
12 (16)
This example describes how to access the web interface of a PLC using a tablet
or smartphone over WLAN.
A: The PLC or network has an active DHCP server
1.
In Network Settings, select IP Assignment: Dynamic (DHCP) and continue to step 3 below.
Make sure that the IP addresses of the PLC and the Wireless Bolt are within
the same Ethernet subnet.
2.
3.
4.
Click on Save and Reboot to restart the Wireless Bolt with the new settings.
5.
SCM-1202-006/SP2139 1.5
Technical Data
13 (16)
Technical Data
General Specifications
Wired Interface Type
Ethernet
Serial RS-232/485 +
Ethernet
CAN + Ethernet
Order code
AWB2000
AWB2010
AWB2020
Range
Up to 100 meters
Antenna
Built-in
Operating temperature
-40 to +65 C
Weight
81 g
Housing
IP class
IP67 for top (outside of host), IP21 for bottom (inside of host)
Dimensions
Mounting
Connector
Included plug connector (2 x 9 pin 3.5 mm Phoenix DFMC 1.5/9ST-3.5 push-in spring connection)
Power supply
Power consumption
Browser support
Configuration
Vibration compatibility
Humidity compatibility
Certifications
SCM-1202-006/SP2139 1.5
Technical Data
14 (16)
Host Communication
Ethernet interface
Serial interface
CAN interface
Digital input
WLAN Specifications
Wireless standards
WLAN 802.11a/b/g/d/e/i/h
Operation modes
111
5 GHz channels
RF output power
16 dBm
Power consumption
Up to 20 Mbit/s
Authentication
Encryption
Bluetooth Specifications
Core specification
4.0
Wireless profiles
Operation modes
RF output power
10 dBm
Power consumption
Up to 1 Mbit/s
Security
SCM-1202-006/SP2139 1.5