Plant ID
Equipment Number:
Equipment Type:
ABC-1234
Vessel
Opolo
Equipment:
Date:
Separator
29th August 2014
Introduction
The following Level 1 and Level 2, Fitness-For-Service assessments were carried out on Grid Referen
accordance with API 579-1, Part 4, for Type 'A' pressurized components subject to general metal los
internal corrosion, using the methods outlined in API 579-2, 4.2. The assessement procedures are b
thickness averaging approach. As per API 579-2, 4.2, the longitudinal weld seam within the area of
corrosion is not considered to be a major structural discontinuity, though the weld joint efficiency o
taken into account.
Summary
The Level 1 assessment criteria are not satisfied due to the average measured thickness in the long
The Level 2 assessment criteria are not satisfied.
Nomenclature
CTP
D
FCA
L
LOSS
Q
Rt
RSFa
c
am
average measured wall thickness of the component based on the circumferential CTP determ
of the inspection.
tsam
average measured wall thickness of the component based on the longitudinal CTP determine
the inspection.
tc
tlim
limiting thickness.
tmin
minimum required wall thickness of the component (see API 579-1, Annex A, paragraph A.2).
minimum required thickness of a conical or cylindrical shell based on the stresses in the circu
hoop direction (see API 579-1, Annex A, paragraph A.2).
min
tLmin
minimum required thickness of a conical or cylindrical shell based on the stresses in the long
(see API 579-1, Annex A, paragraph A.2).
tmm
tnom
nominal or furnished thickness of the component adjusted for mill undertollerance as applica
trd
uniform thickness away from the local metal loss location established by thickness measurem
of the assessment.
Opolo
Equipment:
Date:
ABC-1234
Vessel
Separator
29th August 2014
Note
s
Vessel Data
Material
Maximum Allowable Stress (S)
Design Conditions (P)
Inside Diameter (ID)
Inside Diameter (D)
Inside Radius (IR)
Inside Radius (R)
Nominal Thickness (tnom)
including FCA
excluding FCA
including FCA
excluding FCA
in
in
Inspection Data
The grid used for the inspection and the thickness readings are shown below. The grid spacing set b
Equipment Inspector in the circumferential and longitudinal directions is 1.5 inches based on the co
Figure 1
Inspection Grid
C1
C2
C3
C4
C5
C6
C7
Grid Ref
CML-01
C8
M1
M2
M3
Vessel Shell
M4
M5
M6
Weld Seam
M7
C2
0.75
0.48
0.57
C3
0.75
0.52
0.59
C4
0.75
0.57
0.55
C5
0.75
0.56
0.59
C6
0.75
0.58
0.60
C7
0.75
0.60
0.66
C8
0.75
0.75
0.75
Circumferential
CTP
0.75
0.48
0.55
0.75
0.75
0.75
0.75
0.61
0.62
0.57
0.75
0.47
0.59
0.59
0.75
0.58
0.58
0.61
0.75
0.36
0.57
0.57
0.75
0.58
0.48
0.56
0.75
0.64
0.62
0.49
0.75
0.75
0.75
0.75
0.75
Longitudinal 0.75
CTP
Grid
Spacing
0
0.48
0.47
0.55
0.36
0.48
0.49
0.75
1.5
4.5
7.5
10.5
M4
M5
M6
M7
0.36
0.48
0.49
0.75
Opolo
Equipment:
Date:
ABC-1234
Vessel
Separator
29th August 2014
Perform a Level 1 assessment for internal pressure as per API 579-1, paragraph 4.4.2
(a) STEP 1 - Calculate the minimum required thickness.
C
tmin
PR
(SE 0.6P)
0.430 in
L
tmin
PR
(SE 0.4P)
0.212 in
0.430 in
C
L
tmin max[tmin
, tmin
]
(b) STEP 2 - Thickness profiles are provided, the data for thickness readings is in Table 1, above.
0.360 in
tmm
tc trd FCA
Rt
tmm FCA
(tc )
0.400 in
(e) STEP 5 - Compute the length for thickness averaging from API 579-1, Table 4.5,
with Rt =
0.400 in
RSFa =
0.9
Table 2.3
The equation for Q is:
Q 1.123
1 Rt
1
(1
R
/
RSF
)
t
a
0.5
Q=
50
for Rt RSFa
1
R
t
Q 1.123
1
(1 Rt / RSFa )
Q=
0.4581
0.4581
0.5
Q=
50
for Rt RSFa
NO
Table 4.5
Opolo
Equipment:
Date:
ABC-1234
Vessel
with LOSS =
Separator
29th August 2014
0.000 in
D ID 2(LOSS FCA)
48.200 in
2.564 in
L Q Dtc
(f) STEP 6 - Establish the Critical Thickness Profiles (CTP's) from the thickness profile data. Determi
measured thickness tsam based on the longitudinal CTP and the average measured thickness tcam ba
circumferential CTP.
Longitudinal CTP
Figure 2: Longitudinal Critical Thickness Profile (in)
0.75
0.8
0.75
0.7
tleft
0.6
0.55
0.48
0.5
tright
t1
0.47
tmm
t2
0.48
0.49
7.5
0.36
0.4
0.3
0.2
0.1
0
1.5
4.5
10.5
L = 2.564 in
Grid spacing =
tmm =
1.5 in
0.360 in
tleft =
0.550 in
tright =
0.480 in
2.564 in
L=
(L / 2)
(grid spacing)
(L / 2)
(grid spacing)
t1 =
0.522 in
t2 =
0.463 in
Opolo
Equipment:
Date:
ABC-1234
Vessel
Separator
29th August 2014
(t1 tmm)
(L / 2)
2
(tmm t2 )
(L / 2)
2
A1
A2
A1 =
0.566 in2
A2 =
0.527 in2
A1 + A2 =
1.093 in2
s
tam
(A1 A2 )
L
s
tam
0.426 in
Circumferential CTP
Figure 3: Circumferential Critical Thickness Profile (in)
0.75
0.8
0.75
0.7
tleft
0.6
0.55
0.48
0.5
t3
tmm
tright
t4
0.48
0.49
7.5
0.36
0.4
0.3
0.2
0.1
0
1.5
Grid spacing =
tmm =
0.360 in
tleft =
0.550 in
tright =
0.480 in
2.564 in
L=
1.5 in
4.5
L = 2.564 in
(L / 2)
(grid spacing)
(L / 2)
(grid spacing)
t3 =
0.522 in
t4=
0.463 in
Opolo
Equipment:
Date:
ABC-1234
Vessel
Separator
29th August 2014
(t3 tmm)
(L / 2)
2
(tmm t4 )
(L / 2)
2
A3
A4
A3 =
0.566 in2
A4 =
0.527 in2
A3 + A4 =
1.093 in2
c
tam
(A3 A4 )
L
c
tam
0.426 in
(g) STEP 7 - Determine the acceptability for continued operation using Level 1 criteria in API 579-1
The average measured thickness acceptance is used in this example.
s
tam
FCA
0.326 in
c
tmin
0.430 in
s
c
tam
FCA tmin
NO
c
tam
FCA
0.326 in
L
tmin
0.212 in
c
L
tam
FCA tmin
from STEP 1
from STEP 1
YES
The Level 1 assessment criteria are not satisfied due to the average measured thickness
Opolo
Equipment:
Date:
ABC-1234
Vessel
Separator
29th August 2014
0.150 in
tmm FCA
0.260 in
max[0.5tmin , tlim ]=
0.215 in
YES
Level 2 Assessment
s
(tam
FCA)
0.326 in
RSFa tmin
0.387 in
s
(tam
FCA) (RSFa tmin )
NO
Page 1
Page 2
including FCA
excluding FCA
including FCA
excluding FCA
Grid
Spacing
0
1.5
3
4.5
6
7.5
9
Page 3
Page 4
Page 5
Page 6
Page 7