TDS - Mastertile 40

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

MASTERTILE 40

For fixing of ceramics, marble and


decorative cladding
Description

Coverage

MASTERTILE 40 is a grey cementitious powder formulated


as a high performance fixing adhesive for a wide range of
applications.

Solid bed fixing:

Typical applications

Application procedure

Ceramic wall and floor tiles, terrazzo, quarry tiles and stone
cladding in internal applications. MASTERTILE 40 may be
employed with confidence in institutional or high traffic
conditions. MASTERTILE 40 is suitable for use in kitchens,
showers and wet process areas. For external applications
use MASTERTILE 30.

Surface preparation:
All surfaces must be clean, dimensionally stable, sound and
free from all traces of oil, grease, mould release agent and
curing compound. It should be ensured that tiles are dry,
and free of contaminants that could impair adhesion.

Advantages

Water resistant.
Precision made.
Easy to use.
Economical.
For walls and floors
High adhesive bond strength.

Packaging
MASTERTILE 40 is available in 25kg bags.

Composition
MASTERTILE 40 is a blend of Portland cement, graded
sand and organic polymer.

Typical properties*
Colour
Plastic density
Flash point
Service temperature
Application temperature

Grey
1.80
None
-30C - +100C
+5C to +35C

Notched trowel:

3mm - 6mm depth


5.4kg - 10.8 kg/m
smooth surface 2kg/m

Concrete, screeds, renders, and blockwork should be cured


sufficiently that all shrinkage movement has occurred.
Mixing instructions:
Add MASTERTILE 40 to cool, clean water at the following
rates:
By weight 4.5-5:1, Volume 2.5:1. Mix to a uniform lump free
consistency and allow to stand for 5 minutes before use. Full
bag volumes should ideally be mixed in a forced action
mixer. Part bags should be mixed using a slow speed drill
and mixing paddle.
Application instructions:
Apply MASTERTILE 40 to a uniform thickness of 3 to 6mm
or sufficient to cover the studs or keys on the tile back; on a
working area of not more than 1 m. Solid bed fixing is
recommended for all horizontal applications and for ceramic,
quarry, terrazzo and marble flooring tiles, and vertical heavy
duty applications including artificial stone cladding. If
preferred, MASTERTILE 40 can additionally be buttered on
the backs of the tiles to ensure full adhesive contact. For all
other vertical applications the adhesive bed should be
combed horizontally with a notched trowel to remove
excess.
Tiles should be dry and fixed by pressing into place with
slight twisting motion, ensuring the tile back achieves full
contact with the adhesive.
Note: Do not apply over an area greater than that which can
be covered within the open time of the product.

Yield

Ceramic tiles should never be butt jointed. Leave a


minimum of 2mm around tiles.

25kg bag mixed with 4.5-5 litres of water yields


approximately 16.2 litres of mixed adhesive.

Adjustments to tiles should only be made during the


adhesives open time.

Remove excess adhesive from the face of the tile with a


damp sponge or cloth before it sets. Similarly, joints must be
raked out in readiness for grouting.

Degussa reserves the right to have the true cause of any


difficulty determined by accepted test methods.

Quality and care

Leave for a minimum of 24 hours before grouting.


Select the appropriate grout for joint size and in service use
from the MASTERTILE range.

Watchpoints
Movement joints should be provided in accordance with
normal practice. Refer to published local standards or BS
5385.

All products originating from Degussas Dubai, UAE facility


are manufactured under a management system
independently certified to conform to the requirements of the
quality, environmental and occupational health & safety
standards ISO 9001, ISO 14001 and OHSAS 18001.
08/95 Degussa-UAE revised 05/2004

* Properties listed are only for guidance and are not a guarantee of
performance.

MASTERTILE 40 should not be used, unless modified with


MASTERTILE 200, on painted or metal surfaces, existing
glazed tiled surfaces, or to bond non porous or high density
ceramics such as glass mosaics.
Tiles should not be soaked in water prior to application.
Gypsum plaster boards and surfaces, must be subjected to
pre-treatment. Please consult Degussa Technical Services
for further advice.
Do not apply MASTERTILE 40 greater than 8mm thickness
on horizontal surfaces and 6mm on vertical surfaces.

Codes of practice
Tiling and grouting should be carried out in accordance with
relevant British Standard Codes of Practice.

Safety precautions
As with all chemical products, care should be taken during
use and storage to avoid contact with eyes, mouth, skin and
foodstuffs. Treat splashes to eyes and skin immediately. If
accidentally ingested, seek immediate medical attention.

Storage
Store out of direct sunlight, clear of the ground on pallets
protected from rainfall. Avoid excessive compaction.
Failure to comply with the recommended storage conditions
may result in premature deterioration of the product or
packaging. For specific storage advice consult Degussa's
Technical Services Department.

Note
Field service, where provided, does not constitute
supervisory responsibility. For additional information contact
your local Degussa representative.

Degussa Construction Chemicals UAE LLC


P.O. Box 37127, Dubai, UAE
Tel: +971 4 8851000

Fax: +971 4 8851002

www.degussa-cc.ae

e-mail: [email protected]

Whilst any information contained herein is true, accurate and


represents our best knowledge and experience, no warranty is given or
implied with any recommendations made by us, our representatives or
distributors, as the conditions of use and the competence of any labour
involved in the application are beyond our control.

Certificate No.
963680

As all Degussa technical datasheets are updated on a regular basis it is the user's responsibility to obtain the most recent issue.

Certificate No.
945787

Certificate No.
772556