MDTs Feed Back Updated

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 41

S/N

Link Name

RSL NE

RSL FE

CR_299-CR_1688

-64.2

-63.2

CR_205-CR_222

-51.6

-40.6

CR_6435_CR_6521

-56.3

-50.3

CR_1776-CR_1777

-52.9

-52.5

CR_1630-CR_1631

6
7
8
9
10

6553-6516
6222_6235
1690-1689
1545-1655
CR_6505_2

IN_PWR_HIGH

11

6464-6465

Mustafa Kamal

12
4636-4635
13 CR_273_1626_1
14
CR6157-6158
6487-6429
15
6491-6436
16
6190-6163
17
6214-6211
18
435-278
19
CR1639-CR443-1
20
21
6438
13
6413
14
6326-6322
15
6453-6454
16
475
17
285
18
276
19
20

1688-1689
299-1688

-47.5

Interference
U200

If cable open

3-Jul-16

7/3/2016

CR

Apply date
RSL low
15-02-2016
RSL low
18-02-2016
RSL low
15-02-2016
16-02-2016
RSL low
18-02-2016
RSL low
16-02-2016
15-02-2016

21-Feb-16
19-Feb-16
20-Feb-16
21-Feb-2016 (10:00 to 16:00)

28-Feb-16
28-02-2016
28-02-2016
2-Mar-16
5-Mar-16
7-Mar-2016 (Day time 10AM-6PM)
9-Mar-16
10-Mar-16
29-02-2016

4/3/2016

10/3/2016
10/3/2016
11/3/2016
12/3/2016
13/3/2016
12/3/2016

Reason
The link have MW radio rsl
and Radio Fading margin Unsufficient FME clear the alarm on CM no MDT is applied nor received any MDT escala
Not receive any MDT escalation
No escalation for MDT.

Not receive any MDT escalation

Not receive any MDT escalation


To change due to RSL fluctuation
To change RTN 905 due to MW alarms
Health check for MW link 1690-1689 due to Link fluctuation
and IP clock link failure
Complete HC MW link 1545-1655
Need to apply MDT to avoid from outage/optical module required 6-SL1D-2(SDH-2)-SPI:1
Site 6464 is located in Wadi Airport, in
night time security not allowing to enter airport area. Performance error and
RSL.
MDT for HC Activity 4636-4635
change frequency
to resolve login and visibility issue of U2000
MDT for Clearing of MW Alarms of site 6487
MDT for Clearing of MW Alarms of site 6491
MDT for Clearing of MW Alarms of site 6163
MDT for Clearing of MW Alarms of site 6214
MDT for Clearing of MW Alarms of site (435 need connectors)
Health Check and have to check the RSL level
MDT for Clearing of MW Alarms of site 6438
MDT for Clearing of MW Alarms of site 6413
Complete HC & Interference test for MW link 6326-6322
Complete HC
HC and clear alarm of RET motor fault

MDT for HC & to clear alarm MW_BER_SD for site 285


MDT to clear alarm of MW-LOF for MW link 276-275
MDT to clear alarm of
radio fading margin insufficient for MW link 1688-1689

MDT to clear alarm of radio fading


margin insufficient for MW link 299-1688

location
zafar
zafar

CRQ
CRQ000000580402
CRQ000000580274

Alkharj

Quwavia
CRQ000000580409
Quwavia
Quwavia
Dawadmi
Buraida
Aflaj
Wadi
Quwayia
Shaqra

Alras
Afif

shahab
m.khan
Zafar
Junaid

niaz

CRQ000000580404
CRQ000000580880
CRQ000000581065.
CRQ000000581830
CRQ000000581831
CRQ000000582795
4044575
CRQ000000583699
CRQ000000584578
CRQ000000584813
CRQ000000584825
CRQ000000584839
CRQ000000584832
CRQ000000584837
CRQ000000584827
CRQ000000585034.
CRQ000000585260
CRQ000000585259

4130067

S/N

MW link ID

3190_6193

3190_6193
299-1688

4
5
6
7

1688-1689
CR205
CR232
4702TDD

285_6093

Schedule date
24-03-2016
24-03-2016
14/3/2016
15/4/2016
14-02-2016
14/3/2016
14-03-2016
17-03-2016

Region
NR
NR
CR
CR
CR
CR
CR
CR

8
9

CR276-275

19-03-2017

CR

10

17

U475
U6548

15-03-2016
24-03-2016
24-03-2016
25-03-2016
28-03-2016
2/4/2016
2/4/2016

CR
CR
NR
CR
CR
CR
CR

18
19

6483-6481
6546

2/4/2016
2/4/2016

CR

S/N

Site ID

U205
U323

Schedule date
2/4/2016
2/4/2016

Region
CR
CR

11
12
13
14
15
16

2
3

CR665
U6548
3190_6193
U475
1768

CR

Location Inf0
To achieve RSL
To achieve RSL

3190,6193(2G)(3G)

25-ODU-1(RTNRF-1)-RTNRF:1

299, 400, 556, 476, 6260, 466, 6269, 6280(2G,3G)

26-ODU-1(RTNRF-1)-RTNRF:1
EBBI card to replace
EBBI card to replace
RF unit clock problem
4-ISX2-1(CR_276-CR_275)-RTNIF:1

4-ISX2-1(CR_276-CR_275)-RTNIF:1
MDT to fixed feeder cable routing
To clear ALD out of range
To achieve RSL
To changethe RET changeed
HC complete
To changethe RET
To clear ALD out of range
HC & Fine tunning
Alarm of Eth Link Fault
Location Inf0
EBBI fault
EBBI fault

Affected site
3190,6193(2G)(3G)

1688, 6253, 207, 513, 6248, 299, 400, 476, 556,


6260, 466, 6269, 6280(2G,3G)
CR205(2G,3G)
CR232(2G,3G)
4702(2G,3G,TDD)
285, 446, 6090, 6080, 278, 263, 6102, 435, 430,
288, 6132, 6291, 6139, 6141, 6117, 460, 6081,
Rep_460

276, 6168, 6183, 277, 427, 6176, 6194, 6188,


6210, 6162, 6179(2G,3G)
U665
U6548
3190,6193(2G)(3G)
475(2G, 3G).
3G
475(2G, 3G).
U6548
6480,4741,4740,4739,4738,6533,6482,6534(2G)
(3G).
6546(2G)(3G)(TDD)

Affected site
255(2G)(3G)
323(2G)(3G)

Status

CRQ
CRQ000000592912

Radio
fading Margin Insufficient
radio fading
margin insufficient

EBBI fault
EBBI fault
285,446,6090,6080,
278,263,6102,,435, ,430, 288,
CRQ000000591101
6132, 6291, 6139, 6141, 6117,
460, 6081, Rep_460
alarm of MW-LOF

CRQ000000591105
successfully done
CRQ000000592912

RET Antenna Motor Fault


RET Antenna Motor Fault
Fine tunning
Replace EM6F board

Status

CRQ

To change EBBI board


To change EBBI board

3215

S/N

Site ID

Schedule date

Region

3146-3160

3172-3167

6356-3104

1619-1620

5
6

6464-6462
6436-6437

4/4/2016
5/4/2016
6/4/2016
4/4/2016
11/4/2016
7/4/2016

CR -Alras
CR -Alras
CR -Alras
CR -Riyadh
CR-Wadi
CR-Alkharj

1619-1620

422-1686

1696-1697

9
10

3146-3160
3172-3167

11

6356-3104

12

CR_6157-6158

13

CR6436-CR6437

16/4/2016
17-04-2016
19-04-2016
16-04-2016
18-04-2016
20-04-2016
15-04-2016
16-04-2016

CR -Riyadh
Dowadmi
Dowadmi
Al-Ras
Al-Ras
Al-Ras
Shaqra
Kharj

4721-6470

21-04-2016

Wadi

3140_3144

21-04-2016

Alras

CR_6157-6158

21-04-2016

Shaqra

1619-1620

21-04-2016

CR -Riyadh

6485_6488

21-04-2016

AL-kharj

253-1490

22-04-2016

Dowadmi

6168-276

22-04-2016

Shaqra

6447_6448

22-04-2016

Aflaj

6448-6449

19-04-2016

Aflaj

CR6012_226

23-04-2016

Quwayia

10

422-1686

24-04-2016

Dowadmi

11

1696-1697

23-04-2016

Dowadmi

12

1696-1695

25-04-2016

Dowadmi

13

1692-1691

26-04-2016

Dowadmi

14

1771-1719

27-04-2016

Dowadmi

16

CR276-275

21-04-2016

Quwayia

17

CR232

27-04-2016

Riyadh Miraj

18

CR292

28-04-2016

Dowadmi

20

CR4702

28-04-2016

AL-kharj

15

CR1669

30-04-2016

Dowadmi

22

6432-6429

26-04-2016

Al-kharj

23

CR1713-454

25-04-2016

Shaqra

24

CR1660-1548

25-04-2016

Quwayia

25

DWD1496_P3_LTE

27-04-2016

Dowadmi

26

U238

27-04-2016

Riyadh Miraj

27

CR226-1621

28-04-2016

Riyadh Miraj

28

1614-774

30-04-2016

Riyadh Miraj

29

6012-6011

29-04-2016

Riyadh Miraj

30

4701 LTE

30-04-2016

Wadi

31

U7C6133

30-04-2016

Quwavia

32

U7C6066

1/4/2016

Quwavia

33

U7C530

30-04-2016

Majma

34

U7C513

1/5/2016

Dowadmi

35

U7C458

2/5/2016

Quwavia

36

U7C457

3/5/2016

Quwavia

37

U7C278

4/5/2016

Quwavia

38

U6546

30-04-2016

Alkharj

39

CR6539

1/5/2016

AlKharj

40

U6536

1/5/2016

Wadi

41

U6535

30-04-2016

Aflaj

42

U6534

2/5/2016

Wadi

CR6426

30-04-2016

AL-kharj

6-ISU2-1(CR_3146-CR_3160)-RTNIF:1
Location & Alarms
Inf0
IF_CABLE_OPEN
alarms
SYSTEM CLOCK,
9-PIU-PWROUTPUT.
BD_STATUS
alarm
CLK_LOCK_FAIL
SYSTEM
CLOCK.
26-ODU-ODU:1
alarm
HARD_BAD
23-ODU-1(RTNRF-1)-RTNRF:1
7-CSHO-OTHER
to
Check
RAU 1619 on slot 15
23-ODU-1(RTNRF-1)-RTNRF:1
Improve
RSL & to reslove Perform Errors
3-ISU2-1(CR_6356-CR_6459)-RTNIF:1
To clear interferance.
to Check RAU 1619 on slot 15
Complete HC & to check RAU at slot 4 on site 422.
IF_CABLE_OPEN
HC & To clear
Errors on MWalarms
link CR 1696-1697
To
clear MW alarm
alarms
BD_STATUS
SYSTEM CLOCK,
26-ODU-ODU:
1 alarm
CLK_LOCK_FAIL
HARD_BAD
To clear alarms RPS INDI, Radio RSL low,
LTI,MW LOF,Radio Fading margin insufficient
To Replace RTN905 on MW link CR_6157-6158
MDT for MW linkCR6436-CR6437 to Replace the ODU
To clear MW alarms4721-6470
To clear MW alarms3140-3144
To Replace RTN905 on MW link CR_6157-6158
to Check RAU 1619 on slot 15
MDT to clear BD_ status alarm on MW link CR 6485_6488
MDT to clear RPS_INDI alarm at MW link 253-1490
loss alarm for site 6168 at MW link 6168-276
MDT to MDT
clearto clear
MW ETH
alarm
CF card offline on MW link 6447_6448
MDT to perform interference test & HC @ MW link 6448-6449

MDT to clear MW alarm MW_LOF ,RSL Low at MW link6012-226


Complete HC & to check RAU at slot 4 on site 422.
HC & To clear Errors on MW link CR 1696-1697
Complete HC & to clear MW errors MW link1696-1695
MDT for complete health check to clear errors on MW link 1692-1691
MDT for complete health check to clear errors on MW link 1771-1719

TO resolve the interference issue


MDT for Site CR232 to replace EBBI board

NMON to replace
To clear cell capability degradation alarm
MDT for site 6169 to replace RRU power cable

MDT to resolve the interference


MTD to clear MW alarms Radio fading Margin & NO config.
At MW 1713-454

MDT to clear MW alarm of RPS-INDI & Hard BAD for MW linkCR 1660-1661
RF Unit VSWR Threshold Crossed
RF Unit VSWR Threshold Crossed
To clear MW alarm of RPS INDI at sMW link226-1621

MDT for MW alarm Clearance for MW link 1614-774


MDT for MW alarm Clearance for MW link 6012-6011
4701 RF Unit RX Channel RTWP/RSSI Too Low &VSWR threshold crossed
RF Unit Rx Chaannel RTWP /RSSI too Low alarm
MDT to Clear BSS alarms for site CR U7C6066

RF Unit RX Channel RTWP/RSSI Unbalanced 530


RF Unit RX Channel RTWP/RSSI Unbalanced U7C513
RF Unit RX Channel RTWP/RSSI Unbalanced 458
RF Unit RX Channel RTWP/RSSI Unbalanced U7C457
RF Unit RX Channel RTWP/RSSI Unbalanced U7C278
RF Unit RX Channel RTWP/RSSI Unbalanced U6546
MDT to clear ALD Maintenance Link failure alarm U6539
MDT to clear BSS alarms for site U6536
RET Antenna Not Calibrated
RET Antenna Not Calibrated

MDT for replacing the TDD antenna at 6426

Affected site

3146,3160, 3152, 3169,


318, 6268, 6193(2G) (3G)
2G=
3172,3167(2G)(3G)
6459,3104,3109,3105,628
(2G)6525,
6523, 6521,
6465.6464,6467,6519,
1,3111,230,6223,(2G),
6435,
4715,
6520, 6515, 6493,
6553, 6541,
6516,
(3G)
6524,
6555,
6484, 6491,
1619,1620,1621(2G)(3G)

6517, 6518, 6465,


6522, 4727,
4725, 4726,
3G=
6436,
4719,
4737, 4713
6465.6464,6467,6519,
(3G)6436,
6555,
6520, 6515, 6553,6491,
6516,
6521,
6435,
4725,
4727,
6517,
6518,
6465,
1619,1620,1621(2G)(3G)
4715, 6523,6525, 6523,
6493,
6524,
6522
2G=3146,
3160,
3152,
422,1686(2G)(3G)
3169,
318,
6268,
6193
1696,1697,1695(2G)(3G)
3G=3146,
2G=3172,
31673160,
(2G)
3152,
3169,
318,
6268,
2G= 6525,
6523,
6521,
3G=3172, 3167
6459,3104,3109,3105,628
6193
6435, 4715,
6493, 6541,
(3G)

Purpose
MDT
for MW
MW alarms
alarms Clearance
Clearance
MDT for
SYSTEM CLOCK,
To clear alarms RPS
INDI-Radio RSL low LTI,MW
CLK_LOCK_FAIL
LOF,Radio Fading
margin insufficient
HARD_BAD
HC and check RAU slot 15

RSL and Perform errors


To clear Interference Issue
HC and check RAU slot 15
Complete HC & to check RAU at slot 4 on site 422.
To clear errors & For Complete HC

TO Clear MW alarm on MW link CR3146-3160


MW alarm clearance for Link 3172-3167

6157,402,6158,6167(2G)
1,3111,230,6223,(2G),
MW alarm clearance for Link 6356-3104
6524,
6555, 6484, 6491,
U6157,U6167,U6158,U402
(3G)
6522, 4727,
4725, 4726,
To resolve visibility issue
IF_CABLE_OPEN
,402 (3G)
RTN-6437_2 in slot 23 Facing to
6436, 4719,
4737, 4713 Replace the ODU at
3G= 6436, 6555, 6491, VOLT_LOS,IF_CABLE_OPEN,RADIO_FADING_MARGIN_I
6436 which impact the BSC KPIs .
2G=3140,
NSUFF
6521,
6435,3143,
4725, 3241
4727,
3G=3140,
3143,
4721.6470
2G,3G
4715, 6523,6525, 6523,
6493, 3241
6524, 6522
6157,402,6158,6167(2G)
Power Abnormal 3140,9-PIU-PWROUTPUT
U6157,U6167,U6158,U402
To resolve visibility issue
,402 (3G)
HC and check RAU slot 15
1619,1620,1621(2G)(3G)
2G=6485,6488
To clear BD_status Alrm on site 6485-ODU(21)
3G=6485,6488
253-1490(2G)(3G)

To clear RPS_INDI alarm on site 253 (at location 7-CSHO-OTHER

18 sites
: 2G* 6501, 6503, To clear ETH loss alarm at location 7-EG6-2(E&M)-MAC:1 on site 6168.
6168-276(2G)(3G)
6504, 6505, 6535, 6447,
6447,6448(2G)(3G)
8-CSH-OTHER
6448,
6557, 4716, 6502,
6-ISU2-1(CR_6012-CR_6011)-RTNIF:1
Interference test & HC
4711
4-ISU2-1(CR_6012-CR_6011)-RTNIF:1
3G* 6504, 6535, 6447,
26-ODU-1(RTNRF-1)-RTNRF:1
6448,
4716, 6502, 4711
6012,226(2G)(3G)
24-ODU-1(RTNRF-1)-RTNRF:1
422,1686(2G)(3G)

Complete HC & to check RAU at slot 4 on site 422.

1696,1697,1695(2G)(3G)

To clear errors & For Complete HC

1695-1696 2G 3G

HC and errors on MW link

1692,1691(2G)(3G)
1771,1719
(2G)(3G)

Complete HC to clear MW errors

21=2G 21=3G

To resolve the interference issue

232(2G)(3G)

MDT for Site CR232 to replace EBBI board

292(2G)(3G)

To clear Alarm due to NMON

CR4702(2G)(3G)(LTE)

To replace the faulty RRU

1669(2G)(3G)

MDT for site 6169 to replace RRU power cable

Complete HC to clear MW errors

6429.6432.6433.6430(2G)
(3G)
1713,454(2G)(3G)

Interference issue

53-ODU-1(RTNRF-1)-RTNRF:1
57-ODU-1(FACING 454)-RTNRF:1
55-ODU-1(RTNRF-1)-RTNRF:1

1660,1661,6001,1662(2G)
(3G)

7-CSHO-OTHER

DWD1496_P3_LTE

VSWR

U238(2G)(3G)

VSWR
To clear alrm of RSP INDI at site 226

1614, 774, 1706(2G)(3G)

MW_LOF, Radio_RSL_Low

6012, 6011 (2G) (3G).

MW_LOF, Radio_RSL_Low

4701(2G)(3G)(LTE)

RTWP & VSWR

6133(2G)(3G)

RF Unit Rx Chaannel RTWP /RSSI too Low alarm

U7C6066 (2G)(3G)

RF unit ALD out of range


,OMU board fault,
SAU board fault,

530(2G)(3G)

RF Unit RX Channel RTWP/RSSI Unbalanced 530

513(2G)(3G)

RF Unit RX Channel RTWP/RSSI Unbalanced U7C513

458(2G)(3G)

RF Unit RX Channel RTWP/RSSI Unbalanced 458

457(2G)(3G)

RF Unit RX Channel RTWP/RSSI Unbalanced


U7C457

278(2G)(3G)

RF Unit RX Channel RTWP/RSSI Unbalanced U7C278

U6546(2G)(3G)

RF Unit RX Channel RTWP/RSSI Unbalanced U6546

6539(2G) (3G)

ALD Maintenance alarm

6536(2G)(3G)

ALD maintenance link failure and ALD out of


range alarms

U6535(2G)(3G)

At all sectors

U6534(2G)(3G)

RET antenna not calibrated

6426 (2G) (3G) (4G)

To clear VSWR and Cell capability alarm

CRQ

Done status

CRQ000000596075
CRQ000000596076
CRQ000000596077
CRQ000000596078

CRQ000000597681

pending due to descope

success fully done


done successfully

successfully done
Not avaliable at MW team

pending
pending

CRQ000000600639

pending

CRQ000000600641

pending

CRQ000000600642
CRQ000000600644
CRQ000000600645
CRQ000000600646
CRQ000000600647
CRQ000000600751

successfully done

CRQ000000601037
CRQ000000601038

CRQ000000601039
CRQ000000601040

Hardware RAU2 X 7/A17:

CRQ000000601041

Product No UKL40170/A17 S.No A2310D2S1V

CRQ000000600331
CRQ000000602416
CRQ000000602422
CRQ000000602475
CRQ000000602481

CRQ000000601495

CRQ000000602143
CRQ000000602252

CRQ000000602253
CRQ000000602740
CRQ000000602741

CRQ000000602415

Serial No.:21524101616CAA001831
ODU required BOOM Code: 52410161

ericssion Links

Site|Region

SITE ID

Schedule
date

285|CR

285

17-03-2016

SITE ID

Schedule
Date

NMS MW

276

19-03-2016

SITE ID

Schedule
Date

1622

22-03-2016

SITE ID

Schedule
Date

1622

22-03-2016

NMS MW

FE

Region

Area

CR

Quwayia

FE

Region

Area

276-275

275

CR

Quwayia

NMS MW

FE

Region

Area

NMS MW

FE

Region

Area

285_6093 6093

1622

Custo
Custom
mer
er
Customer
Operation
appro
Involve
approve approved
Brief
MDT/TCN ved
d Site
d
operation
description
TCN/
operatio
time
MDT
n date
#
MDT for 1622
1622FAN_FAIL alarm clearance
MDT
CRQ000000592125
Activity
###

00:00-6:00

Area of coverage
City
Name
Riyadh

Highway
2G 3G LTE
Name
USF7

Area of coverage
City
Name
Riyadh

18 18

USF7

Cascaded Sites Details


2G
285, 446, 6090, 6080, 278, 263, 6102,
435, 430, 288, 6132, 6291, 6139, 6141,
6117, 460, 6081, Rep_460

No.
Cascaded
Sites

Highway
2G 3G LTE
Name

Area of coverage
City
Name

No.
Cascaded
Sites

21 21

Cascaded Sites Details


2G
6162,427,6210,6188,6179,6176,6149
276,6262,6232,6168,6183,6155,4559
6235,6251,6278,4563,6215,6222,277

No.
Cascaded
Sites

Highway
2G 3G LTE
Name

Cascaded Sites Details


2G
(1622, 6044, 6052, 6043, 6042, 6047,
257, 6048, 6049, 6046, 6053) 2G/3G

Area of coverage
City
Name

No.
Cascaded
Sites

Highway
2G 3G LTE
Name

Cascaded Sites Details


2G
(1622, 6044, 6052, 6043, 6042, 6047,
257, 6048, 6049, 6046, 6053) 2G/3G

Implem
enter

Implemen
Im
ter
pac
Contact
t
Number

22, 6044, 6052,


Ziad Khan543125196
6043, 6042, 6047, 257, 6048, 6049, 6046, 6053) 2G/3G

MW / FON / MW&FON / MW
Collocated in BSC

Cascaded Sites Details


3G

LTE

alarm Details

285, 446, 6090, 6080, 278, 263, 6102,


435, 430, 288, 6132, 6291, 6139, 6141,
6117, 460, 6081, Rep_460

MW to clear alarm
MW_BER_SD _285

MW / FON / MW&FON / MW
Collocated in BSC

Cascaded Sites Details


3G
6162,427,6210,6188,6179,6176,6149
276,6262,6232,6168,6183,6155,4559
6235,6251,6278,4563,6215,6222,277

LTE

alarm Details

4-ISX2-1(CR_276-CR_275)RTNIF:1 (MW LOF)

MW / FON / MW&FON / MW
Collocated in BSC

Cascaded Sites Details


3G

LTE

(1622, 6044, 6052, 6043, 6042, 6047,


257, 6048, 6049, 6046, 6053) /3G

alarm Details
CRQ000000592125

MW / FON / MW&FON / MW
Collocated in BSC

Cascaded Sites Details


3G
(1622, 6044, 6052, 6043, 6042, 6047,
257, 6048, 6049, 6046, 6053) /3G

LTE

alarm Details
CRQ000000592125

CRQ

CRQ000000591101

CRQ000000591105

S/N

Site ID

Schedule date

Region

1771-1719

27-04-2016

CR Dowadmi

CR232

27-04-2016

Riyadh Miraj

MW linkConfig.
1619-1620
1+1
1692-1691
1+1
1696-1695
1+1
422-1686
1+1
1697-1696
1+1
1771-1719
1+1

MMU position
Required
14+15-16+17
Check RAU at 1619 slot 15
20+21-20+21
HC to clear errors
2+3-2+3
HC to clear errors
(4+5)-(16+17)Check RAU at 422 slot 4
(2+3)-(6+7)
HC to clear errors
(6+7)-(2+3)
HC to clear errors

Location & Alarms Inf0

Affected site

MDT for complete health check to clear errors on MW link 1771-1719


MDT for Site CR232 to replace EBBI board

1771,1719
(2G)(3G)
232(2G)(3G)

1619 slot 15
Check RAU at 1619 slot 15
HC to clear errors
HC to clear errors
Check RAU at 422 slot 4

Purpose

CRQ

Complete HC to clear MW errors

CRQ000000601041

MDT for Site CR232 to replace EBBI board

CRQ000000602416

S/N
1
2
3
4
5

Name
Zafar Iqbal
Niaz Ali
Zaheer Abbas
Abid Ur rehman
Rizwan

Emp ID
65314
73179
65255
65264
86585

Petty cash Adv


500
500
500
500
500

Region
Dawadmi
Dawadmi
Quwayia
Shaqra
Wadi

Date

Mobily

12/3/2016

11135

1/3/2016
25-02-2016
17-03-2016
21-04-2016

11135
11135
11135
11135

S/N

Site ID

Schedule date

Region

422-1686

24-04-2016

Dowadmi

1619-1620

21-04-2016

CR -Riyadh

1696-1695

25-04-2016

Dowadmi

6432-6429

26-04-2016

Al-kharj

1692-1691

26-04-2016

Dowadmi

MW linkConfig.
1619-1620
1+1
1692-1691
1+1

MMU position
Required
14+15-16+17
Check RAU at 1619 slot 15
20+21-20+21HC to clear errors

1696-1695
1+1
422-1686
1+1
1697-1696
1+1
1771-1719
1+1

2+3-2+3 HC
(4+5)-(16+17)
Check
(2+3)-(6+7) HC
(6+7)-(2+3) HC

to clear errors
RAU at 422 slot 4
to clear errors
to clear errors

Location & Alarms Inf0

Affected site

Complete HC & to check RAU at slot 4 on site 422.

422,1686(2G)(3G)

to Check RAU 1619 on slot 15

1619,1620,1621(2G)(3G)

Complete HC & to clear MW errors MW link1696-1695

1695-1696 2G 3G

MDT to resolve the interference

6429.6432.6433.6430(2G)
(3G)

MDT for complete health check to clear errors on MW link 1692-1691

1692,1691(2G)(3G)

at 1619 slot 15
Check RAU at 1619 slot 15

clear errors

HC to clear errors
HC to clear errors
Check RAU at 422 slot 4

Purpose

CRQ

Complete HC & to check RAU at slot 4 on site 422.

CRQ000000601037 Done

HC and check RAU slot 15

CRQ000000600642

HC and errors on MW link

CRQ000000601039

Interference issue
CRQ000000601495
Complete HC to clear MW errors

CRQ000000601040

Comment
Stand by MMU Faulty Needs
100meter IF cable indoor outdoor
connector of ericssion MM2H card
required.
Safty wire issue as monopole issue
and also nee RAU
As per FT need RAU {S/N
A23103A0F1}
{Hardware
RAU2N13/15} {Product No
UKL40158/15 R1B} at site 1696

Serial
No.:21524101616CAA001831
ODU required BOOM Code:
52410161
Hardware RAU2 X 7/A17
Hardware RAU2 X 7/A17:
Product No UKL40170/A17 S.No
A2310D2S1V

You might also like