Elite 440: Multi-Line Three-Phase Panel Meter
Elite 440: Multi-Line Three-Phase Panel Meter
Elite 440: Multi-Line Three-Phase Panel Meter
Applications
Features
Benefits
(RS-485/Ethernet)
Detachable connectors for easy installation
voltage applications
Cost-effective online monitoring
Field-configurable CT/PT primary and secondary values using
push-buttons
Elite 440
Features
Models
441
442
443 444
445
P-N voltage
Average P-N voltage
P-P voltage
Average P-P voltage
Line current (L1, L2, L3 and Average)
Active / Reactive Current
Frequency
Power factor
Average Power factor
Active Power
Total Active Power
Reactive Power
Total Reactive Power
Apparent Power
Total Apparent Power
Active Total Import / Export Energy
Reactive Import (Q1+Q2) / Export (Q3+Q4) Energy
Reactive (Q1,Q2,Q3,Q4) Energy
Apparent Import / Export Energy
Active / Apparent Forwarded Energy
Reactive Lag / Lead Forwarded Energy
Cumulative MD
Phase Angle
Power On / Off Hours
Load On / Off Hours
Feeder Interruptions Count (When Aux is also off)
Min / Max Values
THD Voltage
THD Current
THD Power
RPM with Freq and VUnb and IUnb
Modbus on RS 485
Note:
Ethernet (add on) module is available for all Elite 440 models as single meter module or gateway
Additional modules (Two pulse input & output or four analogue outputs) can be available in Elite 443 to Elite 448
# Optional software config view is available for reading and configuration
446
447
448
Elite 440
Metering Parameter Accuracy
Parameters
Voltage
0.1
0.1
0.1
Current
0.1
0.2
0.2
kW
0.2
0.5
0.5
kVar
0.2
0.5
0.5
kVA
0.2
0.5
0.5
kWh
0.2
0.5
1.0
kvarh
0.2
0.5
1.0
Frequency*
0.1
0.1
0.1
* 0.05 optional
Connection Diagram
LT34W
HT33W
HT34W
1
2
3
1
2
3
1
2
3
N
V1 V2 V3 VN
AUX
+/P -/N
S1 S2 S1 S2 S1 S2
I1
I2
RS-485
+
S1 S2 S 1 S2 S1 S 2
I3
I1
I2
V1 V2 V3 VN
I3
AUX
+/P -/N
- SG
Auxiliary P
supply N
AUX
+/P -/N
RS-485
- SG
RS-485
- SG
Auxiliary P
supply N
Auxiliary P
supply N
In case of CT/PT operated
meter, ensure that meter is
connected on secondary side
of instrument transformer.
V1 V2 V3 VN
In case of 33W, VN is
replaced by V2 .
Mechanical Dimensions
Available Option
(2 Pulse input & output) Or
4 analogue outputs
m
65 m
96 m
m
45 m
57
65
mm
96 mm
mm
56 mm
55 mm
96
6 mm
96 mm
m
45
58 m
I/O module
Ethernet module
Ethernet
Elite 440
Technical specifications
Common product for HT3/ HT4/ LT application
Common product for 3 P-3 W and 3 P-4 W application
Approvals
Standards
Mechanical
Dimensions (WXHXD)
Weight
Enclosure
Terminals
Max conductor size
Environmental
Ingress protection
Insulation
Impulse withstand
Temperature
Humidity
Feature
Favourite page
CT/VT primary
Communication
Baud rate
Load survey
Modules
2 Digital pulse input and output (single module)
Ethernet
4 analogue outputs
96 x 96 x 65 mm (w/o module);
96 x 96 x 110 mm (with module)
Cut out size 92 x 92 mm
0.5 kg (approx)
FRPC
Combicon connector
2
2.5 mm
On / Off
Configurable in field through keypad
RS485 Modbus half duplex (Default) and data will be available in floating point format
(IEEE754)
From 1200-38400 bps (Default 9600 bps)
40 days for 6 parameters @ 30 minutes integration period
Options for 15 or 60-minute integration period.
Input supports voltage range of 8-40VDC with pulse duration of 5 ms for input 1 and
40 ms for input 2. Output are normally open type, voltage rating of 230 V AC @ 100 mA or
48 V DC @ 100 mA with pulse width of 80 ms or 240 ms
10/100base-T for Modbus over TCP/IP communication
Analogue output supports current range of 4-20 mA non-isolated with loop impedance
750 , auxiliary supply 20-40V DC @ 100 mA
Electrical
Connection type
Wiring configuration
Voltage range :
Measurement voltage range
Tolerance
Aux power supply range
Current range
Main frequency
Accuracy Class
Burden
Elite 200
Digital Panel Meter
This is
Applications
?
Metering of dual-supply installations (mains and backup
generator)
?
Load control applications
Features
?
Accuracy class 1.0 and 0.5s
?
Separate energy registration for mains and backup supply
(such as DG)
?
Online monitoring systems
?
Forwarded energy registration in case of current reversal
?
Commercial and industrial sub-metering applications
?
Accurate readings even at very low current
?
Compact DIN 96 panel meter
Benefits
?
Open-circuit protection for external CTs
?
Easy interfacing with external devices through pulse I/O
?
Minimal installation costs through easy fitting and
detachable connectors
?
Cost-effective online monitoring
?
Helps consumers monitor their consumption
?
One pulse input for switching of metering between mains
and DG
?
One pulse output for load control (load monitoring based
backup supply
?
Time of day tariff registration with maximum demand and
primary value
?
Optical port for local and remote reading
Elite 200
Technical specifications
Electrical
Connection type
Wiring configuration
Voltage range
Current range
Overload
CT-operated
3-phase 4-wire
240 V (L-N) / 415 V (L-L)
1-1.2 A , 5-6 A
Withstand up to 130 % Imax continuous, 20 x Imax for 0.5 s
Accuracy
Mains frequency
Burden
Compliance
Standards
IS14697, IS13779
IEC 62052-11, IEC 62053-21, 22, 23
Mechanical
Dimensions (W x H x D)
Cutout size
Depth behind bezel
Weight
Enclosure
Terminals
96 x 96 x 115 mm
92 x 92 mm (DIN 96)
84 mm
0.4 kg (approx.)
Polycarbonate
Combicon connector
2.5 mm
Environmental
Ingress protection
Dielectric strength
Isolation
Impulse withstand
Temperature
Humidity
IP 50 (front panel)
4 kV RMS, 50Hz
6 kV
-10 C to +55 C (operating)
-25 C to +70 C (storage)
95% non-condensing
Features
Custom backlit LCD
Configurable via keypad
Programmable via keypad
PACT port, Modbus via RS-485 port
1200, 2400, 4800, 9600, 19200 bd (field-configurable through keypad)
240 V AC
100 mA DC max
Display
Favourite page
CT/VT primary
Communications
Baud rate (Modbus)
Pulse output (for load control)
Voltage rating
Current rating
Pulse input
Voltage rating
Current rating