EPDM

Waterproofing membrane

ARDEX ENDURA (INDIA) PRIVATE LIMITED


Corporate Office & Regd. Office:
Unit No. 406 & 407, Brigade Rubix,
No. 20, HMT Campus, Yeshwanthapur Hobli,
Bengaluru - 560013. Karnataka, INDIA.
CIN No: U24233KA1997PTC022383
Tel: +91 80 66746500
Fax: +91 80 66746540
Email: [email protected]
Visit us: www.ardexendura.com

EPDM

Waterproofing membrane

DESCRIPTION

A synthetic rubber with properties which resist


ageing from heat, sunlight and ozone. It has
excellent water vapour impermeability and
toughness and remains flexible at low
temperatures.
EPDM is marketed by ARDEX ENDURA as a
warranted roofing, decking and tanking product
and fixed by their trained and experienced
approved Applicators.

bonding should not be proceeded with under


four hours, thus allowing full evaporation of
solvents absorbed into the substrate. Primers
must be time dried not touch dried.
As new substrate materials continually appear
on the market, consult (Contact
ARDEX ENDURA central technical service
department for more details) for approval of
their use with EPDM.
Seam tape and seam primer must be used for
all EPDM joints.

SUBSTRATE SPECIFICATION

Plywood & Timber Substrates must be dry


when ARDEX ENDURA EPDM is applied. The
plywood and timber substructure shall have a
maximum moisture content of 20% when
EPDM is adhered.
NOTE: LOSP (Light Organic Solvent

Preservative) treated plywood must NOT be


used under EPDM under any circumstances.
New Concrete must be cured for a minimum of
28 days and all curing compounds removed
prior to application. A reduction in cure time
can be achieved by utilising the Ardex
HydrEpoxy System (Contact ARDEX ENDURA
central technical service department for more
details)
Old Concrete must be clean from any
contaminants prior to application

Do not use in temperatures less than 6C.


APPLICATION

Unroll the membrane over the substrate and


allow it to relax for approximately 30 minutes
before seaming or flashing. Membranes are
overlapped, side lap and end laps in
accordance with the installation instructions
and details.
PACKAGING

Thickness
Width
Length

1.00mm
1.35m
25m

1.5mm
1.35m
20m

STORAGE AND SHELF LIFE

Store away from sources of puncture and


physical damage. Store away from ignition
sources and open flame. Unlimited shelf life.

ADHESIVES

1. ARDEX ENDURA WA98, the solvent based


contact adhesive for brushing, spraying and
roller application for fixing to the substrate.
Supplied in 20L plastic containers. The
Coverage of ARDEX ENDURA WA 98.
2. Use Ardex Seam Primer and Seam Tape for
laps
WA98 - The Standard contact brushing,
spray grade and rolling adhesive for fixing to
the substrate and for laps not subject to
periodic ponding. (Pitch 5 and above)
WA98S - Solvent for cleanup of WA98 adhesive.
Seam Primer - A water resistant primer, used
with seam tape for general lap bonding.
Note: Temperature and Humidity
The evaporation of any solvent adhesive
system causes a drop in temperature at the
interface. At times of high humidity this can
result in a micro molecular water layer at the
interface which will result in a failure to bond,
falsely attributed to Adhesive failure. Fixing
should not proceed under these circumstances.

DISPOSAL/SPILLAGE

Spillage of any of the component products


should be absorbed onto sand or other inert
materials and transferred to a suitable
disposable vessel. Disposal of such spillage or
empty packaging should be in accordance with
local waste disposal authority regulations.
For further information please refer to the
Material Safety Data Sheet.
PRECAUTIONS

Exercise caution when lifting, moving,


transporting, storing or handling membrane
rolls to avoid sources of puncture and possible
physical damage.
CONDITIONS OF SALE

Sold subject to the Company's conditions of


sale which are available on request.
NOTE

The information supplied in this datasheet is


based upon extensive experience and is given
in good faith in order to help you. Our Company
policy is one of continuous Research and
Development; we therefore reserve the right to
update this information at any time without
prior notice. We also guarantee the consistent
high quality of our products; however as we
have no control over site conditions or the
execution of the work, we accept no liability for
any loss or damage which may arise as a
result thereof.

TECHNICAL CHARACTERISTICS
Property

Value

Test Method

Specific Gravity

1.2 0.05

ASTM D297

Hardness IRHD
Tensile Strength MPa Min
Elongation at Break

68 5
8.3
300 % Min

ASTM D1415
ASTM D412
ASTM D412

Heat Aging 7 days at 115C


Tensile Retention Min
Elongation Retention

70%
70%

Ozone Resistance 7days at 40C 50 pphm Ozone

No Cracks

ASTM D1149

Water Absorption 7days at 70C change in mass

4% max

ASTM D471

Water vapour Permeance at 23C, 45% RH, perms

0.06 max

ASTM E96

Remains Flexible from

-40C to +110C

Note: For latest updates and additional info,

please consult Central Technical Service


Department for more details. Testing results
and/or copies of Approval Documents for
above - mentioned membranes are available
upon request.

05/15

In cases of extreme absorbency, a priming


coat of 50/50 WA98 adhesive and solvent may
assist water shedding and absorption. However,
a follow up of full strength adhesive for full

You might also like