Res2dinv 2
Res2dinv 2
Res2dinv 2
59
for Windows XP/Vista/7
Rapid 2-D Resistivity & IP inversion
using the least-squares method
Wenner (,,), dipole-dipole, inline pole-pole, poledipole, equatorial dipole-dipole, offset pole-dipole,
Wenner-Schlumberger, gradient
and non-conventional arrays
On land, water and cross-borehole surveys
Geoelectrical Imaging 2D & 3D
GEOTOMO SOFTWARE
Malaysia
www.geoelectrical.com
February 2010
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
Table of Contents
Topic
Page No.
Introduction
1
Computer system requirements and installation
3
Copy protection
6
Theory
7
CD contents
9
Using the program
10
Data file operations and data format
11
Editing the data
16
Changing the program settings
19
Inversion options
25
Topographical modelling
33
Display the inversion results
37
Program settings
42
Help
43
Printing the pseudosections
43
Other useful programs
44
Pitfalls in 2-D inversion
44
Some field examples
46
Trouble shooting
50
Acknowledgements
51
References
52
Appendix A : Dipole-dipole and pole-dipole surveys
55
Appendix B : The Wenner-Schlumberger array
58
Appendix C : Fixing Resistivities
60
Appendix D : The Equatorial Dipole-Dipole array
62
Appendix E : Underwater surveys
63
Appendix F : IP data inversion
76
Appendix G : New batch mode options
80
Appendix H : Speed of graphics display
81
Appendix I : Cross-borehole data inversion
82
Appendix J : Remote electrodes
92
Appendix K : Robust data and model inversion
96
Appendix L : Non-conventional or general arrays
98
Appendix M : Array types in RES2DINV
104
Appendix N : Saving results in SURFER format
106
Appendix O : Model refinement
109
Appendix P : Combining 2-D files
112
Appendix Q : Bedrock edge detection
116
Appendix R : Time-lapse resistivity inversion
119
Appendix S : Incorporating data noise estimates
127
Appendix T : Incorporating boundaries of known layers 129
Appendix U : Special topography information
132
133
138
140
143
144
144
145
Notice of Copyright
RES2DINV is copyrighted by Geotomo Software, 2000-2010. All rights
reserved. No part of this document may be reproduced without written
permission of Geotomo Software.
1
Introduction
RES2DINV is a computer program that will automatically determine a twodimensional (2-D) resistivity model for the subsurface for the data obtained
from electrical imaging surveys (Griffiths and Barker 1993). Since it is a
Windows based program, all Windows compatible graphics cards and printers
are automatically supported. It has been tested with video screen modes of up
to 1600 by 1200 pixels and 16 million colours.
Figure 1 shows an example of the electrodes arrangement and measurement
sequence that can be used for a 2-D electrical imaging survey. This program is
designed to invert large data sets (with about 200 to 21000 data points)
collected with a system with a large number of electrodes (about 25 to 16000
electrodes).
The 2-D model used by the inversion program, which consists of a number of
rectangular blocks, is shown in Figure 2. The arrangement of the blocks is
loosely tied to the distribution of the data points in the pseudosection. The
distribution and size of the blocks is automatically generated by the program
using the distribution of the data points as a rough guide. The depth of the
bottom row of blocks is set to be approximately equal to the equivalent depth
of investigation (Edwards 1977) of the data points with the largest electrode
spacing. The survey is usually carried out with a system where the electrodes
are arranged along a line with a constant spacing between adjacent electrodes.
However, the program can also handle data sets with a non-uniform electrode
spacing.
A forward modelling subroutine is used to calculate the apparent resistivity
values, and a non-linear least-squares optimisation technique is used for the
inversion routine (deGroot-Hedlin and Constable 1990, Loke and Barker
1996a). The program supports both the finite-difference and finite-element
forward modelling techniques. This program can be used for surveys using the
Wenner, pole-pole, dipole-dipole, pole-dipole, Wenner-Schlumberger and
equatorial dipole-dipole (rectangular) arrays. In addition to these common
arrays, the program even supports non-conventional arrays with an almost
unlimited number of possible electrode configurations! You can process
pseudosections with up to 16000 electrodes and 21000 data points at a single
time on a computer with 1 GB RAM. The largest electrode spacing can be up
to 36 times the smallest spacing used in a single data set. The program data
limits will be extended in the future as larger field data sets are encountered.
Besides normal surveys carried out with the electrodes on the ground surface,
the program also supports underwater and cross-borehole surveys!
Figure 2. Arrangement of the blocks used in a model together with the data
points in the pseudosection.
2
Computer system requirements and installation
This program is designed to run on IBM PC compatible microcomputers using
the Windows XP/Vista/7 operating systems. Due to the computational power
required for the 2-D forward modelling and least-squares subroutines, it is
written for 32-bit computer systems with at least 256 megabytes of RAM. On a
Pentium 4 computer, it will take less than a minute to invert the data set
obtained from a survey with about 100 electrodes.
Minimum requirements : Hard disc with at least 256 megabytes free space, and
motherboard with at least 256 megabytes RAM. SVGA colour graphics system
with screen resolution of at least 800 by 600 pixels and 256 colours. Windows
XP/Vista/7 operating system. Pentium III or Pentium 4 (or compatible) CPU.
You should be able to process the largest example data set, DUFUYA.DAT
that has 297 electrodes, with the above computer system. However, it is
recommended that you use a system with 512 (or more) MB memory and at
least 1 GB free hard disc space to process very large data sets with more than
400 electrodes and 3000 data points. This is a 32-bit Windows program that
can access up to 4 gigabytes of memory. The more RAM and free hard disc
space you have, the larger the data set that you can process with this program.
It is also recommended that you use the 1024 by 768 (for 17 inch monitors) or
the 1280 by 1024 (for 19 inch monitors) with 256 (or higher) colours XVGA
graphics mode. You can change the graphics mode by clicking 'Start', and then
'Settings' followed by 'Control Panel' and then 'Display'.
If you had purchased the software with a CD, the following setup manager
should be automatically displayed when you insert the CD.
Keylok USB dongle, click on the Keylok USB Driver to install the driver for
the dongle.
If you had downloaded the programs from the Internet, you will need to install
the programs manually. The RES2DINV package comes in a single
compressed installation file SETUP.EXE that is a Windows based installation
program. To install the program, click Start, and then Settings followed by the
Control Panel, and then Add/Remove Programs. After installing the
RES2DINV.EXE program, you should click the Run JACOBWIN option
undret he File menu to create several support files. You only have to run this
option once after installing the RES2DINV program.
For the full version of this software, it is necessary to install a system driver for
the dongle. If you need to install the driver manually, follow the steps below.
a).
For users with the Keylok key (parallel port or USB)
Please run the INSTALL.EXE program in the KEYLOK_SYSTEM_DRIVER
folder for the Keylok drivers. This program will install the appropriate driver
for your operating system into your computer hard-disk..
If you are using the Keylok USB key, please follow the steps below.
1). If the RES2DINV and RES3DINV software are already installed in your
computer, you will need to replace the RES2DINV.EXE and RES3DINV.EXE
files with the latest versions in the CD. You need to copy the RES2DINV.EXE
and RES3DINV.EXE files from the Win_Updates folder to the appropriate
folders in you computer (usually C:\RES2DINV and C:\RES3DINV).
2). If the RES2DINV and RES3DINV software have not yet been installed, run
the SETUP.EXE files found in the RES2DINV and RES3DINV folders in the
CD.
3). First, make sure that the USB dongle is not attached to the computer. You
will now need to install the software driver for the Keylok dongle by running
the INSTALL.EXE program (using the INSTALL.EXE /B command) in the
KEYLOK_SYSTEM_DRIVER folder in the CD. Please note that in Windows
NT/2000/XP you must have Administrator privileges in order to install the
driver.
4). After installing the driver, switch off the computer and attach the USB
dongle. It is recommended that you attach the USB dongle to the first USB port
on the computer. Some older computer systems have trouble detecting it on the
second USB port. Now switch on the computer. Windows will display a
message saying that it has found a new hardware and it should then
automatically copy the driver for the dongle.
5). Try running the RES2DINV and RES3DINV program, and they should be
able to detect the dongle. If the programs still cannot detect the dongle, you
will need to install the driver manually. Click the Control Panel under Settings,
and then select the Add New Hardware option. Windows then searches for
new Plug and Play devices. Click the No the device isnt in the list and then
the No I want to select the hardware from a list options. Near the near bottom
of hardware list, the USB Dongle will probably be displayed. Click it, and
then the Have Disk option in the next dialog box. Then click Browse and
change the folder to the KEYLOK_SYSTEM_DRIVER folder in the CD. A
list of files with the inf extension will then be displayed. For Windows
98/Me select the usbkey98.inf file, for Windows NT/2000/XP select the
Usbkey2K.inf file. After that click OK, and a Copying files dialog box
should be shown, and Windows should copy the drivers.
After copying the drivers, you need to restart the computer, and the
RES2DINV/RES3DINV programs should then be able to detect the dongle.
More information about the system drivers can be obtained at the following
web site : www.keylok.com
Vista : For Windows Vista, you need to use the driver found in the
InstallVistaUSB.zip file in the KEYLOK_SYSTEM_DRIVER\Vista Driver
folder in the CD provided. The instructions are given in the To Install USB
Dongle on Vista.pdf file.
b).
For users with the Rainbow Technologies Sentinel SuperPro key
This key was distributed with very old versions of the software, and is no
longer distributed but is still supported in the programs updates. Run the
RainbowSSD5.39.2.exe file in the RAINBOW_SYSTEM_DRIVER
subdirectory in the CDROM. This program will automatically install the
system driver for the dongle. After installing the driver, restart the computer for
the driver to take effect. In case of problems, use the SuperProMedic.exe
program to check the condition of the dongle. More information about the
system drivers can be obtained at the following web site : www.rainbow.com.
Practically all computers have an in-built power management system that slows
down and eventually shuts down the computer system if the keyboard/mouse
or hard disc is not accessed after a certain time limit. This can interfere with the
operation of the RES2DINV program if you are inverting a large data set since
this program spends most of the time calculating using the CPU only.
Windows also has an in-built screen saver functions that replaces the contents
of the screen with a screen saver program. Before running the RES2DINV
program, you will need to disable both the power management and screen
saver programs. To disable them, you need to take the following steps.
1). Shortly after the computer is switched on, it usually runs a memory check.
During this time, you need to go to the CMOS Setup program in the computer
BIOS. For most computers, this is done by pressing the "Del" key. The CMOS
setup screen will next be shown. Go to the section which concerns power
management, and disable the power management options for the computer.
2). After Windows starts up, go to the Control Panel. Click the Power
Management or Power Options icon. Here it will probably show the number of
minutes after which Windows will automatically shut down the computer if the
mouse or keyboard is not used. Disable this feature.
3). Next, still within the Control Panel, click the Display icon. In the Display
program, click the Screen Saver option and disable the screen saver. This will
ensure that Windows does not automatically run a screen saver.
After disabling the power management and screen saver options, you can
physically switch off the monitor if the computer is left running overnight.
There should preferably not be too many background programs running before
executing this program. The active background programs are usually shown on
the 'Start' bar at the bottom of the screen. By shutting down the other programs,
more memory will be available to this program. This will reduce memory to
hard disc swapping that slows down the program. Before carrying out the
inversion of a large data set with more than a thousand data points, please close
down other active programs. Also, using the Set program priority sub-option
in the File option of the main menu, set the program priority to High to
ensure that it is not interrupted by other programs while inverting the data set.
In Windows, a Recycle Bin program is sometimes used to save recently deleted
files. This feature might prove to be a nuisance when inverting very large data
sets as the program uses a number of temporary files. Although the program
deletes the files, they might end up in the Recycle Bin, and quickly fill up your
hard disc! The RES2DINV program will, by default, use the hard disc drive
with the largest amount of free space as the buffer drive. It is recommended
that you disable the Recycle Bin for this drive. This can be done by clicking the
Recycle Bin icon with the right mouse button, followed by the Properties
option. You can then configure the settings for each hard disc drive.
It is recommended that you remove the CD disc, if present, from the CD-ROM
drive when using this program. Due to the multi-tasking nature of these
systems, sometimes the program on the disc might be launched while
RES2DINV is busy inverting a large data set! For all versions of Windows, it
is recommended that you run the SCANDISK program occasionally to check
the condition of the hard disc, and also the Defragmentation program to reduce
file fragmentation.
3
Copy protection
A USB hardware key (dongle) is supplied with the registered version of the
program. After installing the driver, attach this key to a USB port of your
computer. The demonstration version of the program does not require a
hardware key but some important features of the program cannot be used.
Older versions of this software use a dongle that is attached to the parallel
printer port of your computer. You can attach the 25-pin connector of the
printer to the other end of the key. The program should be able to detect the
dongle if the parallel printer port follows the IBM PC specifications. If it is
unable to find the dongle, the printer port might not completely IBM PC
compatible. In this case, after connecting the dongle to the computer, connect a
printer to the other end of the dongle. Turn on the printer and print out
something to confirm that the printer port is working. Leave the printer on, and
then try to run the RES2DINV.EXE program again. If you are still not able to
solve the problem, please contact the Rainbow Technologies or Keylok
company by email.
Many new notebook computers do not have a parallel port. If you have the
parallel port type of dongle, and need to use the program on such a notebook
computer, it is recommended that you exchange it with a USB dongle. Please
contact [email protected] on the procedure to exchange the dongle.
4
Theory
The inversion routine used by the program is based on the smoothnessconstrained least-squares method (deGroot-Hedlin and Constable 1990, Sasaki
1992). The smoothness-constrained least-squares method is based on the
following equation
(JTJ + uF)d = JTg
(1)
large data sets and requires less memory. You can also use the conventional
Gauss-Newton method in this program. It is much than the quasi-Newton
method, but in areas with large resistivity contrasts of greater than 10:1, it
gives slightly better results. A third option in this program is to use the GaussNewton method for the first 2 or 3 iterations, after which the quasi-Newton
method is used. In many cases, this provides the best compromise (Loke and
Dahlin 2002). Due to improvements in the program code and PCs it is
recommended that the option to use the Gauss-Newton method should be the
default method, particularly for the final interpretation model, as for most data
sets, the data inversion take only minutes on modern PC systems.
The 2-D model used by this program divides the subsurface into a number of
rectangular blocks (Figure 2). The purpose of this program is to determine the
resistivity of the rectangular blocks that will produce an apparent resistivity
pseudosection that agrees with the actual measurements. For the Wenner and
Schlumberger arrays, the thickness of the first layer of blocks is set at 0.5 times
the electrode spacing. For the pole-pole, dipole-dipole and pole-dipole arrays,
the thickness is set to about 0.9, 0.3 and 0.6 times the electrode spacing
respectively. The thickness of each subsequent deeper layer is normally
increased by 10% (or 25%). The depths of the layers can also be changed
manually by the user.
The optimization method basically tries to reduce the difference between the
calculated and measured apparent resistivity values by adjusting the resistivity
of the model blocks. A measure of this difference is given by the root-meansquared (RMS) error. However the model with the lowest possible RMS error
can sometimes show large and unrealistic variations in the model resistivity
values and might not always be the "best" model from a geological perspective.
In general the most prudent approach is to choose the model at the iteration
after which the RMS error does not change significantly. This usually occurs
between the 3rd and 5th iterations.
More information about the inversion method can be found in the free
Tutorial Notes on electrical imaging (Tutorial : 2-D and 3-D electrical
imaging surveys) that is available on the www.geoelectrical.com web site.
5
CD contents
The Res2dinv folder in the CD contains the main setup file SETUP.EXE. After
installing this setup file, you should have the following files in the subdirectory
containing the RES2DINV program.
RES2DINV.EXE
JACOBWIN.EXE
REGISTER.TXT
LANDFILL.DAT
GRUNDFOR.DAT
ODARSLOV.DAT
ROMO.DAT
DUFUYA.DAT
GLADOE2.DAT
BLOCKWEN.DAT
BLOCKDIP.DAT
BLOCKTWO.DAT
RATHCRO.DAT
PIPESCHL.DAT
WATER.DAT
LAKELELIA.DAT
MODEL101.DAT
DIPOLEN5.DAT
BLUERIDGE.DAT
WENSCHN5.DAT
PDIPREV.DAT
10
POLDPIN5.DAT
OHMMAPPER.DAT
KNIVSAS.DAT
ITALY_CAVE.DAT
IPMODEL.DAT
IPSHAN.DAT
IPMAGUSI.DAT
IPKENN.DAT
BOREHOLE.DAT
BOREHIP.DAT
BORELANC.DAT
BOREDIFF.DAT
BORERES.DAT
BOREHOLE_TOPO.
DAT
TIMELAPS.DAT
MIXED.DAT
CROMER02.DAT
RES2DINV.HLP
RES2DINV.CNT
RES2DINV.INI
RES2DINV.IN2
README.TXT
RESIS.BTH
6
Using the program
After running the SETUP.EXE installation program, and the JACOBWIN.EXE
program, the main program RES2DINV.EXE and the support files
(GRADWEN, GRADTWO and GRADDIP) and example data files should be
in the same subdirectory in the hard disc. Please check the condition of the
hard disc using the CHKDSK and SCANDISK programs, or similar programs
in software utility packages such as Norton Utilities.
To run the resistivity inversion program, click the RES2DINV icon. The
program will first check the computer system to ensure that it has the necessary
resources that this program requires. It will check for the available memory and
11
hard disc space. If the program displays a warning, you should quit from the
program and make the necessary changes. After checking the computer
configuration, the program will then display the following Main Menu bar near
the top of the screen.
You can select an option by clicking it with the mouse cursor. If this is the first
time you are using the program, try reading in the resistivity data file
LANDFILL.DAT provided with the program. Then select the inversion option
to carry out an inversion of the data set. Figure 3 shows an example of the
results from the inversion of this data set. After reading a data set, you should
generally check for bad data points using the Edit data option. In the
following sections, a more detailed description of each item in the above menu
is given.
7
Data file operations and data format
When you select the File option, the following menu choices are displayed.
12
Read data file - When you select this option, the list of files in the current
directory that has an extension of .DAT will be displayed. You can use the
mouse or keyboard to select the appropriate file, or to change the folder.
The apparent resistivity values must first be typed into a text file. You can use
any general purpose text editor, such as the Windows NOTEPAD program.
The data are arranged in an ASCII delimited manner where a comma or blank
space or a LF/CR is used to separate different numerical data items. The
program requires the data to be arranged in a certain format. If there is a
problem in running this program, one possible cause is that the input data was
arranged in a wrong format. An example of an input data set is given in the file
LANDFILL.DAT. The initial section of this file with a description of the data
format is given in the 'Comments' section below.
LANDFILL.DAT file
LANDFILL SURVEY
3.0
1
334
1
0
4.50
3.0
84.9
7.50
3.0
62.8
Comments
| Line 1- Name of survey line
| Line 2 - Smallest electrode spacing
| Line 3 - Array type (Wenner = 1, Pole-pole = 2,
| Dipole-dipole = 3, Pole-dipole = 6, Schlumberger = 7
| Equatorial dipole- dipole - 8 )
| Line 4 - Total number of data points
| Line 5 - Type of x-location for data points.
| Enter 0 if location of first electrode in array used to
| indicate the x-location. Enter 1 if mid-point of the
| array (i.e. location of data point in pseudosection)
| is used.
| Line 6 - Flag for IP data (enter 0 for resistivity data
| only)
| Line 7 - The x-location, electrode spacing and
| measured apparent resistivity value for the first
| data point.
|Line 8 - The x-location, electrode spacing and
| measured apparent resistivity value for the second
| data point.
Subsequent lines give similar information for the other data points. This is
followed by four 0's that are reserved flags for other features.
The dipole-dipole, pole-dipole and Schlumberger array data sets have a
slightly different format since an extra parameter, the dipole separation factor,
is needed. Please refer to Appendices A and B for a description of the data
formats for these arrays. The file BLUERIDGE.DAT is an example data set for
the dipole-dipole array.
13
-100 33
-40 34.5
14
-20 35.0
0 35.209
10 34.904
20 33.678
30 32.264
40 31.191
50 30.560
60 29.905
70 29.200
80 28.774
90 28.569
100 28.473
110 28.553
120 28.462
130 28.486
140 28.601
150 28.652
160 28.825
170 28.996
180 29.284
190 29.643
200 29.563
270 30.0
300 33
2
0
0
0
0
Note that the topography data is placed immediately after the apparent
resistivity data points. The first item is a flag to indicate whether the file
contains topography data. If there is no topography data, its value is 0. Enter 1
or 2 if topographical data is present. In the case where the actual horizontal and
vertical coordinates of points along the survey line are given, enter 1. Even if
the actual horizontal distances are given in the topography data section, you
must still use the x-distance along the ground surface in the apparent resistivity
data section. In most surveys the distances of the points along the ground
surface, and not true horizontal distances, are actually measured with a tape. In
this case, enter a value of 2 for the topography data flag. This is followed by
the number of topographical data points.
It is not necessary to measure the elevation for each electrode. For example, the
data in the GLADOE2.DAT file involves 161 electrodes but only the
15
16
8
Editing the data
This option enables you to make some changes to the data you have read from
the input data file described in the previous option. It will enable you to
remove bad data points, and to select a portion of the data set to invert for very
large data sets. When you select this option, the following submenu will be
displayed:
Exterminate bad datum points - In this option, the apparent resistivity data
values are displayed in the form of profiles for each data level. You can use the
mouse to remove any bad data point. The main purpose of this option is to
remove data points that have resistivity values that are clearly wrong. Such bad
data points could be due to the failure of the relays at one of the electrodes,
poor electrode ground contact due to dry soil, or shorting across the cables due
to very wet ground conditions. These bad data points usually have apparent
resistivity values that are obviously too large or too small compared to the
neighboring data points. The best way to handle such bad points is to drop
them so that they do not influence the model obtained. Figure 4 shows an
example of a data set with a few bad points. To remove a bad data point, move
the cross-shaped cursor with the mouse to the data point and click the left
mouse button. The colour of the data point should change from black to purple.
If you click the same data point again, it will not be removed from the data set.
To quit from this option, just press the Q key or click the Exit option.
Splice large data set - This option enables you to choose a section of the full
data set (which is too large to be processed at a single time) to invert. After
choosing this option, the distribution of the data points in a pseudosection will
be displayed. You can select a section of the data set to invert by using the
arrow keys. Full instructions on the keys to use are displayed on the screen.
The data points selected will be marked by purple crosses or dots, whereas the
remaining data points are black. At the top of the display, the left and right
limits of the section selected are marked by yellow vertical lines. If there are
too many data points in the lower levels, you can reduce the number of data
17
points by selecting only odd or even points in a level. To do this, move the
horizontal yellow marker on the left side of the display up or down to the level
you want to decimate using the up and down arrow keys. Then press D to
decimate the data points in that level. The program allows you to read in a file
that involves up to 15000 electrodes. Using this option, you can select a section
of the data set (which covers up to a maximum of 500 electrodes and 8000 data
points for a system with 256 megabytes RAM) to invert. The entire data set can
then be inverted by inverting successive subsections of the data set. After
selecting the data set subsection you want invert, you should select the
"Exterminate bad data points" option to check for bad data points. In general, it
is recommended that you try to invert the entire data set at one go. In most
cases, this can be easily done by adding more RAM and free hard disc space to
your computer.
Reverse pseudosection - This option flips the pseudosection horizontally from
left to right. This is helpful when you have parallel survey lines but the surveys
were started from different ends.
Figure 4 : Example of a data set with a few bad data points. The data is
displayed using the "Exterminate bad data points" option.
Change location of first electrode - This allows you to change the location of
the first electrode in the survey line. It is basically intended for plotting
purposes, so that overlapping survey lines have the same x-locations for
electrodes that coincide.
18
Edit data file - When you select this option, the text editor (by default
NOTEPAD) will start up. To return to the RES2DINV program, you must first
exit from the text editor program.
Run another program - This option enables you to run another program. It is
mainly intended for cases where the program had not been installed and thus
not in the list of programs recorded in the Windows Start and Program option.
Choose font - In this option, you can choose the type of font used by the
program when it draws the pseudosections. The default font is an Arial font.
The other choice is the system font. With the default Arial font the program
should be able to fit everything into the screen when drawing the
pseudosections, even with the 800x600 graphics mode. The system font usually
has bolder characters when might be better when making printouts of the
images. It is recommended that you use the 1024x768 or higher resolution
graphics mode when you use the system font.
Restore colours - This option restores the default colour scheme used by the
program.
19
9.
Changing the program settings
The program has a set of predefined settings for the damping factors and other
variables that generally give satisfactory results for most data sets. However, in
some situations, you might get better results by modifying the parameters that
control the inversion process. When you select the "Change Settings" option,
the following list of menu options is displayed.
To change a particular setting, move the mouse cursor to the appropriate line
and then just click it. A message will then appear which gives some
information about the values you can use, and the type of information you need
to enter.
Inversion Damping Parameters
The following options modify the use of the damping factor u in equation (1).
Damping factors - In this option, you can set the initial value for the damping
factor in equation (1), as well as the minimum damping factor. If the data set is
very noisy, you should use a relatively larger damping factor (for example 0.3).
If the data set is less noisy, use a smaller initial damping factor (for example
0.1). The inversion subroutine will generally reduce the damping factor in
equation (1) after each iteration. However, a minimum limit for the damping
factor must be set to stabilize the inversion process. The minimum value
should usually set to about one-fifth the value of the initial damping factor.
Change of damping factor with depth - Since the resolution of the resistivity
method decreases exponentially with depth, the damping factor used in the
inversion least-squares method is normally also increased with each deeper
layer. This is done in order to stabilize the inversion process. Normally, the
damping factor is increased by 1.05 times with each deeper layer, but you can
change it. Use a larger value if the model shows unnatural oscillations in the
resistivity values in the lower sections. This will help to suppress the
20
oscillations. You can also select the choice to allow the program to determine
the value to increase the damping factor with depth automatically. This might
be a good choice if the thickness of the layers is much thinner than the default
values, for example if you had reduced the unit electrode spacing by half in the
data file in order to produce a model with smaller model blocks.
Optimise damping factor - If you select this option, the program will attempt to
find the optimum damping factor u in equation (1) that gives the lowest RMS
error in each iteration. By optimizing the damping factor, the number of
iterations the program requires to converge can be significantly reduced.
However, the time taken per iteration will be increased. For small to medium
size data sets, this can significantly reduce the overall computer time needed to
invert the data set. For very large data sets with more than 1000 data points, the
time taken in each iteration could be significantly increased as it is necessary to
solve the least-squares equation more than once per iteration. Use this option
with care as the model with the lowest RMS error is not always the best
model, particularly for very noisy data sets (see the Theory section). In
practice, the improvement in the results by optimising the damping factor for
most data sets is rather small.
Limit range of model resistivity - When you select this option, the following
dialog box will be shown.
This option allows you to limit the range of resistivity values that the inversion
subroutine will give. In the above example, the upper limit for is 20 times the
average model resistivity value for the previous iteration while the lower limit
is 0.05 times (i.e. 1/20 times). The program uses soft limits that allow the
actual resistivity model values to exceed the limits to a certain degree.
However, this option will avoid extremely small or large model resistivity
values that are physically unrealistic. The user can also choose to use the
inversion model obtained at the first iteration as the reference model.
21
Vertical to horizontal flatness filter ratio - You can select the ratio of the
damping factor for the vertical flatness filter (fz) to the horizontal flatness filter
(fx). By default, the same damping factor is used for both. However, if the
anomalies in the pseudosection are elongated vertically, you can force the
program to produce models that are also elongated vertically by selecting a
higher value (for example 2.0) for the ratio of the vertical to horizontal flatness
filter. For anomalies that are elongated horizontally, choose a smaller value
(e.g. 0.5).
Mesh Parameters
These set of options change the finite-difference or finite-element mesh used in
the forward modeling subroutine.
Finite mesh grid size - You can choose a mesh grid used by the forward
modelling program to have 2 or 4 nodes between adjacent electrodes. With 4
nodes per electrode spacing, the calculated apparent resistivity values would be
more accurate (particularly for large resistivity contrasts). However, the
computer time and memory required are correspondingly larger. By default, the
program will use the 2 nodes option if the data set involves more than 90
electrodes.
Use finite-element method - This program allows you to use either the finitedifference or finite-element method to calculate the apparent resistivity values.
By default, the program will use the finite-difference method, which is faster, if
the data set does not contain topography. If the data set contains topography,
the default choice is the finite-element method.
Mesh refinement - This option allows you to use a finer mesh (in the vertical
direction) for the finite-difference or finite-element method. The apparent
resistivity values calculated by either method will be more accurate with a finer
mesh, but the computer time and memory required will be greater. The use of a
finer mesh can give better results for cases where subsurface resistivity
22
Line search - The inversion routine determines the change in the model
parameters by solving equation (1). Normally the parameter change vector d
will result in a model with a lower RMS error. In the event that the RMS error
increases, you have two options. One option is to perform a line search using
quartic interpolation to find the optimum step size for the change in the
resistivity of the model blocks. The program will attempt to reduce the RMS
error, but it can also be trapped in a local minimum. The alternative is to ignore
the increase in the RMS error, and hope that the next iteration will lead to a
smaller RMS error. This might enable you to jump out of a local minimum, but
it could also lead a further increase in the RMS error. A third alternative is to
perform a line search at each iteration. This will usually give the optimum step
size, but will require at least one forward computation per iteration. In some
cases, the extra forward computations could be worthwhile if it reduces the
number of iterations needed to bring the RMS error down to an acceptable
level. To select a particular setting, just click the appropriate button. This
setting will only affect the inversion process for the third iteration onwards. For
the first two iterations, where the largest changes in the RMS error usually
occurs, the program will always carry out a line search to find the optimum
step size to further reduce the RMS error.
Percentage change for line search - The line search method used can estimate
the expected change in the apparent resistivity RMS error. If the expected
23
change in the RMS error is too small, it might not be worthwhile to proceed
with the line search to determine the optimum step size for the model
parameter change vector. Normally a value between 0.1 and 1.0 % is used.
Convergence limit - This sets the lower limit for the relative change in the
RMS error between 2 iterations. By default, a value of 5% is used. In this
program the relative change in the RMS error, rather than an absolute RMS
value, is used to accommodate different data sets with different degrees of
noise present.
RMS convergence limit This sets the percentage RMS error in the inversion
of the apparent resistivity data where the program will stop after the model
produce has an RMS error less than this limit. Normally a value of between 2%
and 5% should be used, depending on the quality of the data.
Number of iterations - This allows the user to set the maximum number of
iterations for the inversion routine. By default the maximum number of
iterations is set to 5. For most data sets, this is probably sufficient. When the
inversion routine reaches this maximum limit, it will ask the user for the
number of additional iterations if you wish to continue with the inversion
process. It is usually not necessary to use more than 10 iterations.
Model resistivity values check - The program will display a warning if after an
iteration in the inversion of the data set, a model resistivity value becomes too
large (more than 20 times the maximum apparent resistivity value) or too small
(less than 1/20 the minimum apparent resistivity value). This option allows you
to disable the warning.
Data/Display Selection
This section has minor options for pre-processing of data files and display of
the sections during the inversion.
24
25
10.
Inversion options
This option enables you to carry out the inversion of the data set that you had
read in using the "File" option. You can also display the arrangement of the
blocks used by the inversion model, as well as to change some of the
parameters that control the inversion process. On selecting this option the
following menu will be displayed.
26
values. In some cases, particularly for very noisy data sets, better results might
be obtained by applying a smoothness constraint on the model resistivity
values as well. The resulting least-squares equation is given by
(JTJ + uF)d = JTg - uFr
(2)
where r is a vector containing the logarithm of the model resistivity values.
While for the same damping factors this will usually produce a model with a
larger apparent resistivity RMS error, this modification will ensure that the
resulting model shows a smooth variation in the resistivity values.
Use combined inversion method - This option is intended for use in unusual
situations where the data sensitivity values of the model blocks are
significantly distorted by large resistivity variations. In some situations, such as
a survey over a very low resistivity body, the current paths could be distorted
such that parts of the subsurface are not well mapped and have very low data
sensitivity values in the inversion model. This could lead to large distortions
just below the low resistivity body. By combining the Marquardt (or ridge
regression) and Occam (or smoothness-constrained) inversion methods, the
distortions in some cases might be reduced. This option should be used as a last
resort if everything else fails! It seems to give better results in resolving
compact structures where the width and thickness are slightly smaller than the
depth, such as a cave or ore-body whose size is just slightly less than its depth.
In theory, it is possible to just use the Marquardt (or ridge regression) method
alone. However, it has been found that this method is unstable when the data
contains noise if a model with a relatively large number of model parameters is
used.
Select robust inversion This allows you to select the robust or blocky
inversion method. It should be used when sharp boundaries are expected to be
present. Please refer to Appendix K for further details.
Choose logarithm of apparent resistivity - By default, the program will use the
logarithm of the apparent resistivity values as the data parameter when carrying
out the inversion. For most cases, this gives the best results. In some cases, for
example with negative or zero apparent resistivity, this is not possible. This
option enables the apparent resistivity value by itself to be used for such
situations.
Jacobian matrix calculation - In this program you have three options in the
calculation of the Jacobian matrix J in equation (1). The fastest method is to
use the quasi-Newton method to estimate the Jacobian matrix (Loke and
Barker 1996a). This might be a good alternative to use in the field where a
slower laptop computer with more limited memory is frequently used. The
most accurate and slowest method is to recalculate the Jacobian matrix for all
iterations. This requires a fast computer with preferably at least 256 megabytes
of RAM, and about 512 megabytes free hard disc space for very large data sets.
27
A third alternative is to recalculate the Jacobian matrix for the first 2 iterations
only, and use the quasi-Newton updating method for subsequent iterations. The
largest changes in the Jacobian matrix usually occurs in the first few iterations.
So in many cases, a limited recalculation of the Jacobian matrix gives the best
compromise between speed and accuracy. By default, the program will choose
the limited recalculation option for the Jacobian matrix. However, the default
settings can be changed by the user in this menu option. The quasi-Newton
option is useful to get a quick look at the results, particularly in the field during
the course of a survey using a laptop computer. For the final model, it is best to
use the limited recalculation option on a faster desktop computer with more
RAM and free hard disc space. In areas with large resistivity contrasts, where
the largest apparent resistivity value is more than 10 times the smallest value,
recalculating the Jacobian matrix for all iterations produces models with
boundaries which are a shade sharper than those produced by the quasi-Newton
method.
Type of optimisation method This option allows you to choose two different
methods to solve the least-squares equation (1). On selecting this menu option,
the following dialog box will be shown.
28
about 0.5% (i.e. a convergence limit of 0.005 in the above dialog box) seems
to provide a solution that is almost the same as that obtained by the Standard
Gauss-Newton method. Setting a higher accuracy, for example 0.1%, will in
theory give a result that is even closer to the Standard Gauss-Newton method
but this is at the expense of a longer inversion time. For very large data sets
and models (usually over 10000 data points/model cells), a data compression
option is provided with the Incomplete Gauss-Newton method. This can
significantly reduce the computer memory required.
For data sets from very long survey lines (over 2000 electrode positions), a
sparse inversion option is provided that can greatly reduce the computer time
and memory required. For example, the inversion of an underwater survey data
set with nearly 7500 electrode positions was reduced by a factor of 10 (to about
101 minutes hours on a 3.2GHz P4 computer) with the sparse inversion option.
This method inverts the entire data set and model at a single time to produce a
continuous and seamless model.
Model Discretization
These options allow you to modify the way the program subdivides the
subsurface into cells that is used as the inversion model.
Display model blocks - This option will display the distribution of the model
blocks and data points. The data points will be plotted at the median depth of
investigation (Edwards 1977) for the array used. The program has a maximum
limit of 24 model layers. If you had chosen the 10% option for the increase in
the layers thickness, and the bottom layer is above the bottom row of data
points, you should change to the 25% option.
Change thickness of layers - In this option you can choose a model where the
thickness of the layers increase by 10% or by 25% with each deeper layer.
Choose the 10% option if there are only a small number (8 or less) of data
levels. If there are a large number of sparse data levels, the 25% option might
be better. Within this option, you can also allow the number of model blocks to
exceed the number of data points. The program normally uses a model where
29
the depth to the deepest layer does not exceed the maximum pseudodepth in
the data set. To use a model that spans a deeper depth range, you can change
the factor to increase model depth range, for eg. from 1.0 to 1.30 to increase
the model depth range by 30%.
Modify depths to layers - This option allows you to change the depth of the
layers used by the inversion model. You can adjust the depths so that some of
the boundaries coincide with known depths from borehole and other data.
Use extended model This option extends the model cells to the edges of the
survey line (Figure 5c).
Allow number of model blocks to exceed datum points - By default, the
program will try to arrange the position and size of the model cells such that
they do not exceed the number of data points. This is probably the best option
for large and medium size data sets collected with more than about 50
electrodes, particularly where the distribution of the data points with the larger
spacings is more sparse. In some cases, the width of the model cells in the
lower layers might be larger than those in the upper layers. However, for
smaller data sets, it might be useful to relax this constrain, and allow the
number of model parameters to exceed the number of data points. This will
produce a model where the interior cells in all layers have a uniform width that
is equals to the smallest electrode spacing (Figure 5b).
Make sure model blocks have same widths The model shown in Figure 5b
have model cells that are wider at the edges. This option will ensure that all the
cells have the same width that is equal to the unit electrode spacing.
Reduce effect of side blocks This option affects the calculation of the
Jacobian matrix values for the model blocks located at the sides and bottom of
the model section. Normally, for a block located at the side, the contributions
by all the mesh elements associated with the model block are added up right to
the edge of the mesh. This gives a greater weight to the side block compared to
the interior blocks. In some cases, particularly when the robust inversion option
is used, this can result in unusually a high or low resistivity value for the side
block. This option leaves out the contribution of the mesh elements outside the
limits of the survey line to the Jacobian matrix values for the side blocks.
Change width of blocks This option allows the user to force the program to
use model cells which are wider than one unit electrode spacing for all the
layers.
Use model refinement Please refer to Appendix P for the details.
30
Type of cross-borehole model - There are two choices for the type of model
you can use for the inversion of cross-borehole data. You can choose to use the
Standard Model where the dimensions of the model blocks are the same as the
spacing between the electrodes on the ground surface and in the boreholes.
Alternatively, you can use a model with smaller blocks where the size of the
blocks is half that of the Standard Model (see Figure 20 in Appendix I).
31
Display blocks sensitivity - This will show a plot of the sensitivity of the
blocks used in the inversion model. The sensitivity value is a measure of the
amount of information about the resistivity of a model block contained in the
measured data set. The higher the sensitivity value, the more reliable is the
model resistivity value. In general, the blocks near the surface usually have
higher sensitivity values because the sensitivity function has very large values
near the electrodes. The blocks at the sides and bottom also have high
sensitivity values due to the much larger size of these blocks that are extended
to the edges of the finite-difference or finite-element mesh. If you had carried
out an inversion of the data set before calling this option, the program will
make use of the Jacobian matrix of the last iteration. Otherwise, it will
calculate the Jacobian matrix for a homogenous earth model.
Display subsurface sensitivity - This shows a plot of the sensitivity of the
subsurface for blocks of equal size. This basically eliminates the effect of
changes in the model block size so that it shows more clearly the change of the
subsurface sensitivity with depth and location.
Normalise sensitivity values By default, the calculated sensitivity values are
normalised by dividing with the average sensitivity value. In this option, you
can choose not to normalise the sensitivity values.
Generate model blocks This option generates the model cells by making use
of the model sensitivity values. Please refer to Appendix L for a description of
this option.
32
IP Options
Value in RESIS.BTH
DATA FILE 1
RATHCRO.DAT
RATHCRO.INV
0.15
0.03
ALWAYS
33
Convergence limit
Percentage change for line search
Number of iterations
Vertical/Horizontal flatness filter ratio
Thickness of model layers increase
Finite-difference grid size
Include smoothing of model resistivity
Reduce number of topographical datum points
Carry out topographical correction
Type of linear trend to remove
Type of Jacobian matrix calculation
5.0
0.4
6
1.00
10
4
NO
YES
YES
END-TO-END
LIMITED RECALCULATION
If you do not wish to carry out the topographical corrections, just enter No at
the appropriate line. To remove a linear least-squares or average trend, enter
Linear or Average in the file. Even if the data set does not contain
topographical data, you still must enter the topographical processing
information. Although in this case the topographical processing information
will be ignored by the program, you must still type in something at the
appropriate lines or else the program cannot read in the parameters for the
following data files in the correct sequence. The other options for the type of
Jacobian matrix calculation are Quasi-Newton and Recalculate. The
information for the other data files to be processed follow the same format.
Please refer to the example file RESIS.BTH. An example of an extended batch
file that includes more inversion parameters is the file RESIS_NEW.BTH.
A new Batch mode script file format is also described in Appendix G that
makes use of the IVP files that are created by the RES2DINV program. It is
easier to use since the user does not need to deal with the details about the
format of file containing the inversion parameters.
11.
Topographical modelling
If there is significant topographical relief along the survey line, the effect of the
topographical effects can be accounted for if the horizontal and vertical
coordinates of a number of points along the survey line are known. When the
program reads in a data file with topography data (please refer to section 7 for
the data format), it will automatically select the finite-element method that
incorporates the topography into the modelling mesh used. In this case, the
topographic modelling will be automatically carried out by the program when
you invert the data set. When you select the Topography Option menu, the
following submenu will be displayed:
34
Distorted finite-element grid with uniform distortion : This method, and the
next two methods, use a distorted finite-element grid such that the surface
nodes of the mesh match the actual topography. This gives more accurate
results than the older method of using the correction factors for a homogeneous
earth model calculated with the finite-element method (Fox et al. 1980) which
can cause distortions in cases where large resistivity variations occur near the
surface (Tong and Yang 1990, Loke 2000). In this particular option, the nodes
below the surface (and thus also the model layers) are shifted to the same
extent as the surface nodes.
35
Figure 6. Topography linear trend removal for the Rathcroghan mound data
set.
36
37
12.
Displaying the inversion results
In this option, you can read in a data file or the output file produced by the
inversion subroutine and display the measured and calculated apparent
resistivity pseudosections and the model section. Within this option, you can
change the contour interval used for drawing the pseudo and model sections,
the vertical scale of the sections, and include topography in the model section.
You can also change the colour scheme used by the program. If you had earlier
read in an input data file or used the inversion option in the Main Menu, the
program will first read the last file used. After selecting this option on the Main
Menu bar, the program will switch to the Window for displaying the
pseudosections and model section. To return to the Main menu, you will need
to Exit from this window. This window has the following top menu bar.
Read data file with inversion results - You can read in the output data file
produced by the inversion subroutine or an input data file.
Save data in XYZ format - You can save the inversion results into a disc file
with a format used by many contouring programs, such as Geosoft. This is a
separate program sold by GEOSOFT Inc. which enables you to use more
sophisticated contouring techniques than those used by the RES2DINV
program.
Save data in SURFER format This saves the data and model sections in
SURFER format. Please refer to Appendix N for the details.
Model output in LUND format - This is a data format used by the LUND
Imaging System produced by ABEM. You can save the model resistivity
values in the .RHO and .RMS files used by the MODSEC program.
38
Save contour values - This option saves the values used to draw the contours in
the pseudo and model sections.
39
Display data and model sections - Select this option to plot the model and
apparent resistivity pseudosections on the screen.
Include topography in model display - For inversion results where topographic
modelling were earlier carried out, you can incorporate the topography into the
model section by calculating that the true depth and location of the model
blocks below the surface. Figure 8 shows an example of a model section with
the topography. The field data for this survey (as well as the Landfill example
in Figure 3) was measured using a Campus Geopulse resistivity imaging
system manufactured by Campus Geophysical Instruments Ltd.
For both display options, you will be asked to enter the iteration number and
the contour intervals. After the section is displayed, you can display the results
for the next iteration by pressing the PgDn key. Similarly, pressing the PgUp
key will display the results for the previous iteration.
Choose resistivity or IP display - If the data set has IP data as well, this option
allows you to choose to display the resistivity or IP sections. You can also
display both the resistivity and IP model sections at the same time.
Type of pole-dipole display - This option is only relevant for pole-dipole data
sets with measurements with the forward and reverse pole-dipole arrays
(see Appendix A). Here you can choose to display the apparent resistivity
values measured with the array in the forward or reverse configuration.
The Change display settings option enables you to change the parameters
that control the way the apparent resistivity pseudosections and the model
section are displayed. The following submenu will be displayed when you click
this option.
40
Default colour scheme - This will reset the colour scheme used for colouring
the sections to a default system used by the program.
Customise colour scheme - This enables the user to change the colours used for
the sections.
Read customise colour scheme - You can change the colour scheme to a set of
customise colours that was earlier saved in a disk file.
Number of sections to display - You can choose to display 1, 2 or 3 sections on
the screen. By default, all the 3 sections (the observed and calculated apparent
resistivity pseudosections and the model section) are displayed.
Apparent resistivity difference - You can choose to display either the
calculated apparent resistivity pseudosection itself, or the percentage difference
between the logarithms of the calculated and observed apparent resistivity
values.
Vertical display scaling factor - This option allows you to specify the ratio of
the vertical scale to the horizontal scale, i.e. the vertical exaggeration factor, in
the display. Convenient values to use are 2.0, 1.5 and 1.0. If you enter a value
41
of 0.0, the program will use a default scaling factor so that the display can fit
into the display screen.
Horizontal plotting scale - This allows you to change the horizontal scale, in
terms of number of pixels per unit electrode spacing. This option is useful
when you want to plot the results from different survey lines with different
numbers of electrodes, with the same scale.
Show locations of datum points - By default, the location of the data points
(and centres of the model blocks) will be shown by white dots in the colour
pseudosection display. You can choose not to display the dots with this option.
Resistivity or conductivity display - The resistivity pseudosections and model
sections are normally displayed. However, you can display the sections using
conductivity values (i.e. the reciprocal of the resistivity) which is more
commonly used in certain fields, such as hydrogeology.
Display pseudodepth values - For the apparent resistivity pseudosections, you
can display the pseudodepth values on the vertical scale, or display the
electrode spacing and n factors (where applicable).
Colour/Black-White display - By default, the program will display the
pseudosections and model section in colour. This option allows you to display
the sections in black and white, possibly for making printouts on normal laser
printers. The program provides two choices for the black and white display.
The first choice is to use pure black and white colours together with a dithering
method to provide the different tones. Such screen images can be printed on
almost any printer. The second choice is to use a grey scale where different
shades of grey, ranging from pure white to pure black, is used. You will
probably need a laser printer to make reasonably good printouts of the grey
scale images.
Type of model display - In this option, you can display the resistivity values in
the model section in the form of contours (the default choice), or in the form of
rectangular blocks which constitute the inversion model. The contoured section
makes it easier to visualise geological structures, while finer features might be
more easily detected in the rectangular blocks section.
When the Edit data option is selected, the following RMS error statistics
submenu is displayed. This option provides another means of removing bad
data points from the data set. In fact, for cross-borehole or certain types of nonconventional arrays data where the apparent resistivity values cannot be
conveniently displayed in the form of a pseudosection or profiles, this is the
primary method to remove the bad data points.
42
RMS error statistics - This suboption just displays the distribution of the
percentage difference between the logarithms of the observed and calculated
apparent resistivity values. It can only be used after carrying out a trial
inversion of the data set. To save some time, you could use the quasi-Newton
method to carry out the trial inversion (see section 10). On selecting this
suboption, the distribution of the RMS errors will be displayed in the form of a
bar chart. It is expected the bad data points will have relatively large
errors, for example above 100 percent. To remove the points with large
errors, just move the green cursor line to set the cut-off error limit to remove
the bad data points.
The Print option on the main menu bar enables you to save the screen image
as a BMP or PCX graphics file, or to make a direct printout with a printer by
using the Windows Paintbrush program. On selecting this option, the following
submenu will be displayed.
Saving the screen image into the form of a BMP or PCX graphics file allows
you to edit the picture with a bit-mapped graphics program, such as the
Windows PaintBrush program, before printing it (see section 15).
13.
Program settings
By default, the Windows Paintbrush is used as the program to manipulate and
print the BMP or PCX graphics file, and the NOTEPAD program is used as the
text editor. You can change these default choices by changing the appropriate
lines in the RES2DINV.INI file which should be located in the same
subdirectory as the RES2DINV.EXE program.. For example, a configuration
file with the following contents :[programs]
paint=c:\psp\psp.exe
editor=c:\gwd\gwd.exe
43
[files]
extension=*.lok
input=c:\res2dinv\
output=c:\res2dinv\
will use the Paint Shop Pro graphics program (located in the subdirectory
C:\PSP) and the GWD text editor (in the C:\GWD subdirectory). It will also
look for files with the extension LOK when you choose the option to read in a
data file. The default subdirectory with the data files is C:\RES2DINV, and the
same subdirectory is used for the output files.
14.
Help
If you click the Help option, the Windows help file for the program will be
displayed. Clicking the Info option will display the copyright notice.
15.
Printing the pseudosections
Besides displaying the pseudosections on the screen, you can make a printout
of the model sections. There are three methods of making a printout.
The simplest method is to use the RES2DINV.EXE to display the
pseudosection and model sections that you want to print by using the Display
inversion results option in the Main Menu. After the program has completed
drawing the pseudosection, click the Print option. This will display options to
save the screen as a BMP file, a PCX file or to call up the PaintBrush program
to print the file. If you need to print the screen image together with some text, it
might be more convenient to save the screen image as a BMP or PCX file. You
can later insert the picture directly into the document if the word processor,
such as Microsoft Word for Windows or Lotus Amipro or WordPerfect, allows
you to import graphics files.
Another method is to save the information into a XYZ file (see File section),
which is a general format supported by a number of dedicated graphics
contouring/plotting program. With such a program, you can redraw the model
sections and print them. This is particularly useful if you want to combine the
results from different survey lines within the same area to make a pseudo 3-D
plot of the structures. If you want to include topography in the model values
saved in the XYZ file, you will need to first run the Include topography in
model section option before saving the XYZ file. In this case, the XYZ file
will contain the model values without the topography, followed by a section
with the model after incorporating the topography.
44
The third method is to save the model information into SURFER format, and
use the SURFER for Windows program to draw and print the sections. Please
refer to Appendix N for details about this option.
16
Other useful programs
Two shareware programs that have been found to be useful are the Paint Shop
Pro image processing program, and the GWD text editor program. Both are
Windows based programs. The Paint Shop Pro program enables you to carry
out a number of sophisticated processing to enhance the BMP and PCX bitmapped graphics files. For example, you can convert the files to a GIF format
which takes up much less space compared to the BMP and PCX files. The
GWD text editor is a professional level editor which enables you to carry out
many operations not possible with the NOTEPAD program. You can make use
of these programs, instead of the default Microsoft Paintbrush and NOTEPAD
program, by modifying the appropriate lines in the RES2DINV.INI file. The
file RES2DINV.IN2 gives such an example.
There are also a number of fine shareware paint programs and text editors
which you can download directly from Internet shareware sites. Besides Paint
Shop Pro, the paint programs I have tested are Lview Pro, VuePrint and
Graphics Workshop for Windows. All of these programs allow you to change
the BMP and PCX files to the GIF format which can dramatically reduce the
size of the graphics files. You can download these shareware programs from
most Internet shareware sites, such as www.softseek.com.
The SURFER 2-D drawing program from Golden Software Inc.
(www.golden.com) has a large variety of useful options for drawing sections.
The RES2DINV program has an option to export the data to the SURFER
format.
17
Pitfalls in 2-D inversion
If the program still does not give a satisfactory model (assuming that the input
data is in the correct format), it could be due to one of the following problems.
Garbage In - Garbage Out : One common problem is bad data points. Check
for unusually low or high apparent resistivity values. These anomalous values
can be caused by instrumentation errors during the field survey, poor electrode
contact in dry, sandy or stony ground, shorting of electrodes due to very wet
conditions or metal objects (such as fences, pipes etc.) or mistakes such as
attaching electrodes to the wrong connectors. You can easily pick out these
anomalous values using the "Edit data" option described earlier. Remember, a
good model requires good data.
45
46
apparent resistivity and IP values for a variety of 3-D structures for different
electrode arrays. This will give you an idea of the extent of the 3-D effects.
There is a discussion on other interesting pitfalls in the free Tutorial notes on
electrical imaging that is available on the www.geoelectrical.com web site.
18
Some field examples
Some examples of field data sets that were inverted with this program are
given below :Grundfor Line 2 - This survey was carried out by the Department of Earth
Sciences, University of Aarhus, Denmark to map the lithology of the nearsurface unconsolidated sediments and aquifers in the Grundfor area
(Christensen and Sorensen 1994). The low resistivity zones in the inversion
model (Figure 9) consist of more clayey Quaternary glacial deposits while the
high resistivity areas consist of more sandy deposits. The model obtained was
confirmed by a number of boreholes along this line. This is a moderately large
data set with 447 data points and 141 electrodes. On a 90 MHz Pentium it took
about 1033 seconds (17.2 minutes) to invert this data set, while on a 266 MHz
Pentium II it took about 158 seconds (2.6 minutes).
Odarslov Dyke - The dyke causes a prominent high apparent resistivity zone
near the middle of the pseudosection (Dahlin 1996) in the upper part of Figure
10. This is a particularly difficult data set to invert as the width of the high
resistivity dyke is smaller than the depth to the lower section of the dyke. Thus
the lower part of the dyke is not well resolved. If the damping factor used is too
small, this will result in oscillations in the resistivity values in the model
section. To invert this data set, the weight of the vertical flatness filter was set
at twice that of the horizontal filter since the dyke has a predominantly vertical
direction. The robust data inversion option (see Appendix K) was used to
reduce the effect of a few data points that might be more noisy on the inversion
results. Since there is a sharp and distinct contrast between the resistivity of
igneous dyke and the surrounding sedimentary rocks, the robust model
inversion option (Appendix K) was also used. In the model section, the dyke
shows up as a prominent high resistivity body with vertical sides. This data set
has 701 data points and 181 electrodes. The Grundfor and Odarslov dyke
surveys were carried out using the LUND Automatic Resistivity Imaging
System produced by ABEM Instrument AB.
47
Figure 10: The observed apparent resistivity pseudosection for the Odarslov
dyke survey together with an inversion model.
48
Figure 11. Mapping of holes in a clay layer, U.S.A. (a) Apparent resistivity
pseudosection for the survey to map holes in the lower clay layer. (b) Inversion
model and (c) sensitivity values of the model cells used by the inversion
program.
Holes in clay layer - U.S.A.
This survey was carried out for the purpose of mapping holes in a clay layer
that underlies 8 to 20 feet of clean sand (Cromwell pers. comm.). The results
from the electrical imaging survey were subsequently confirmed by boreholes.
The pseudosection from one line from this survey is shown in Figure 11a. The
data in the pseudosection was built up using data from horizontally overlapping
survey lines. One interesting feature of this survey is that it demonstrates the
misleading nature of the pseudosection, particularly for the dipole-dipole array.
In the inversion model, a high resistivity anomaly is detected below the 200 ft.
mark, which is probably a hole in the lower clay layer (Figure 11b). This
feature falls in an area in the pseudosection where there is an apparent gap in
the data. However, a plot of the sensitivity value of the cells used in the
inversion model shows that the model cells in the area of the high resistivity
49
body have higher sensitivity values (i.e. more reliable model resistivity values)
than adjacent areas at the same depth with more data points in the
pseudosection plot (Figure 11c). This phenomenon is due to the shape of the
contours in the sensitivity function of the dipole-dipole array, where the areas
with the highest sensitivity values are beneath the C1C2 and P1P2 dipoles, and
not at the plotting point below the center of the array. If the model cells are
placed only at the location of the data points, the high resistivity body will be
missing from the inversion model, and an important subsurface feature would
not be detected!
Bauchi groundwater survey - A groundwater survey using the Wenner
Alpha, Beta and Wenner arrays was carried in the Bauchi area of Nigeria
(Acworth 1987). In this region, groundwater is frequently found in the
weathered layer above the crystalline bedrock. The weathered layer is thicker
in areas with fractures in the bedrock, and thus such fractures are good targets
for groundwater. The Wenner Gamma array data set is shown in Figure 12 as
an example. To emphasize the boundary between the soil layer and the
bedrock, the robust inversion option was used (Appendix K). The thickness of
the lower resistivity weathered layer is generally about 10 to 20 metres. There
is a narrow vertical low resistivity zone with a width of less than 20 metres
below the 190 metres mark that is probably a fracture zone in the bedrock. A
borehole well that was placed at the 175 metres mark that lies at the edge of the
fracture zone had yields that were lower than expected. The placement of the
well was largely based on resistivity and EM profiling measurements using the
Geonics EM34-3, and before fast 2-D resistivity inversion microcomputer
software was widely available.
Figure 12. Bauchi Wenner Gamma array survey. (a). Apparent resistivity
pseudosection. (b) The inversion model with topography.
50
19
Trouble shooting
A brief compilation of possible problems and their possible causes and
solutions is given in this section.
Insufficient memory : If the program cannot find sufficient memory, one
possible reason is that it has been reserved for other programs. In this case, you
will need to remove the other active programs. In Windows, the active
programs are usually shown on the Start menu bar near the bottom of the
screen. If you have less than 512 megabytes RAM, it is recommended that you
buy some RAM.
Program stops when it tries to calculate the partial derivatives :
The partial derivative values are stored in the files GRADWEN.10,
GRADTWO.10, GRADDIP.10, GRADWEN.25, GRADTWO.25 and
GRADDIP.25. First check that these files are in the same sub-directory of your
hard disc as the RES2DINV.EXE files. If they are there, one possible problem
could be due to bad sectors in the hard disc. You need to scan the hard disk to
check for possible unmarked bad sectors. Also, check that the hard disc has at
least 256 megabytes of free space that the program needs to store temporary
files for large data sets.
Program crashes when it tries to invert the data set : This could be due to
data arranged in the wrong format or other errors in the data set. When the
program reads the data file, it will check for some common errors such as zero
or negative apparent resistivity values. However, there might be some new
unexpected errors. One preliminary check you could make is to view the data
using the "Edit data" option described in section 8. If you still cannot find the
error, please send a copy of the data set to the company who sold you this
program (or the author of this program) by email.
Program cannot find dongle : If the program cannot find the hardware key, it
will run as a demonstration program. If you had securely attached the dongle
provided to the printer port and the program still cannot detect it, please refer
to section 3 for a method to check for the source of the problem. The Keylok
system driver must be installed for the USB dongle. During the installation of
the driver, the program will copy the necessary system (SYS) files needed by
Windows to detect the USB dongle. Please refer to the installation note
provided with the USB dongle for further details.
51
Acknowledgements
Dr. Torleif Dahlin of Lund University in Sweden provided the interesting and
challenging Odarslov Dyke, Gladkvarn and Knivsas data sets. The Grundfor
and Cromer data sets were kindly provided by Dr. Niels B. Christensen of the
University of Aarhus in Denmark and Dr. Torleif Dahlin. The Rathcroghan
data set was kindly provided by Dr. Kevin Barton and Dr. Colin Brown from
data collected by the Applied Geophysics Unit of University College Galway,
Ireland. Dr. Andrew Binley of Lancaster University kindly provided the crossborehole field data set. Mr. Ernst Neiderleithinger of Buro Fur Geophysik
Lorenz (Germany) supplied the Landfill data set that provided the initial
motivation to write this program to handle large 2-D data sets. I am also
grateful to Prof. Douglas Oldenburg of the University of British Columbia in
Canada for pointing out the some of the possible advantages of using equation
(2). The Bauchi data was provided by Dr. Ian Acworth of School of Civil and
Environmental Engineering, The Un. of New South Wales, Australia. Many
thanks to Richard Cromwell and Rory Retzlaff of Golder Assoc. (Seattle) for
the survey example to map holes in a clay layer. Bill Seaton of ATS, Virginia
kindly provided the BLUERIDGE.DAT data set. Dr. Fabrizio Cara of the
Instituto Nazionale di Geofisica e Vulcanologia, Italy generously supplied the
ITALY_CAVE.DAT data set. I would also like to thank Ron Kaufman of
Technos Inc. for his permission to use the Lake Lelia underwater field survey
example. I would like to acknowledge Michel Ritz of IRD, France for kindly
providing the BOREHOLE_TOPO.DAT example data set. The data set for the
floating electrodes survey along the So Francisco River in Brazil was kindly
provided by Rodrigo Machado. Finally, a special thanks to Rob Barker of The
University of Birmingham (U.K.) for the Birmingham time-lapse, Stud Farm
bedrock survey and the Clifton (with Julian Scott) data sets, and his advice
through the years.
52
References
Acworth, R. I., 1987. The development of crystalline basement aquifers in a
tropical
environment:
Quarterly
Journal
Engineering
Geology, 20, 265-272.
Barker, R. and Moore, J., 1998. The application of time-lapse electrical
tomography in groundwater studies. The Leading Edge, 17, 14541458.
Christensen N.B. and Sorensen K.I., 1994. Integrated use of electromagnetic
methods for hydrogeological investigations. Proceedings of the
Symposium on the Application of Geophysics to Engineering and
Environmental Problems, March 1994, Boston, Massachusetts, 163176.
Claerbout, J.F. and Muir, F., 1973. Robust modeling with erratic data.
Geophysics, 38, 826-844.
Dahlin, T., 1996. 2D resistivity surveying for environmental and engineering
applications. First Break, 14, 275-284.
Dahlin, T. and Zhou, B., 2004. A numerical comparison of 2D resistivity
imaging using ten electrode arrays. Geophysical Prospecting, 52, 379398.
Dahlin, T. and Zhou, B., 2005. Multiple gradient array measurements for
multi-channel 2D resistivity imaging. Near Surface Geophysics, in
review.
deGroot-Hedlin, C. and Constable, S., 1990, Occam's inversion to generate
smooth, two-dimensional models form magnetotelluric data.
Geophysics, 55, 1613-1624.
Edwards, L.S., 1977, A modified pseudosection for resistivity and inducedpolarization. Geophysics, 42, 1020-1036.
Fox, R.C., Hohmann, G.W., Killpack,T.J. and Rijo, L., 1980, Topographic
effects in resistivity and induced polarization surveys. Geophysics, 45,
75-93.
Griffiths D.H. and Barker R.D. 1993, Two-dimensional resistivity imaging and
modelling in areas of complex geology. Journal of Applied
Geophysics, 29, 211-226.
Griffiths, D.H., Turnbull, J. and Olayinka, A.I., 1990, Two-dimensional
resistivity mapping with a computer-controlled array. First Break, 8,
121-129.
Hallof, P.G., 1990, Reconnaissance and detailed geophysical results, Granite
Mountain Area Pershing County, Nevada. in Fink, J.B., McAlister,
E.O., Sternberg, B.K., Wieduwilt, W.G. and Ward, S.H. (Eds), 1990,
Induced polarization : Applications and case histories : Investigations
in Geophysics No. 4, Soc. Expl. Geophys.
Keller G.V. and Frischknecht F.C.,1966. Electrical methods in geophysical
prospecting. Pergamon Press Inc., Oxford.
53
Loke, M.H., 1999. Time-lapse resistivity imaging inversion. 5th Meeting of the
Environmental and Engineering Geophysical Society European
Section Proceedings. Em1.
Loke, M.H., 2000. Topographic modelling in resistivity imaging inversion.
62nd EAGE Conference & Technical Exhibition Extended Abstracts,
D-2.
Loke, M.H., 2001. Tutorial : 2-D and 3-D electrical imaging surveys. Geotomo
Software, Malaysia.
Loke, M.H. and Barker, R.D., 1996a, Rapid least-squares inversion of apparent
resistivity pseudosections by a quasi-Newton method. Geophysical
Prospecting, 44, 131-152 .
Loke, M.H. and Barker, R.D., 1996b, Practical techniques for 3D resistivity
surveys and data inversion. Geophysical Prospecting, 44, 499-523.
Loke, M.H. and Dahlin, T., 2002. A comparison of the Gauss-Newton and
quasi-Newton methods in resistivity imaging inversion. Journal of
Applied Geophysics, 49, 149-162.
Loke, M.H., Acworth, I. and Dahlin, T., 2003. A comparison of smooth and
blocky inversion methods in 2D electrical imaging surveys.
Exploration Geophysics, 34, 182-187.
Nelson, G.D. and Van Voorhis, 1973, Letter to the editor regarding the paper
Complex resistivity spectra of porphyry copper mineralization.
Geophysics, 38, 984.
Niederleithinger, E., 1994, Use of high resolution geomagnetics, 2D-DCgeoelectrics and induced polarisation in environmental investigations.
Paper presented at SAGEEP '94, Boston, USA.
Olivar, A., de Lime, L. and Sharma, M.M., 1990. A grain conductivity
approach to shaly sandstones. Geophysics, 55, 1347-1356.
Robain, H., Albouy, Y., Dabas, M., Descloitres, M., Camerlynck, C.,
Menchler, P. and Tabbagh, A., 1997, The location of infinite
electrodes in pole-pole electrical surveys: consequences for 2D
imaging. Journal of Applied Geophysics, 41, 313-333.
Sasaki, Y., 1992, Resolution of resistivity tomography inferred from numerical
simulation. Geophysical Prospecting, 40, 453-464.
Scott, J.B.T., Barker, R.D. Peacock, S., 2000. Combined seismic refraction and
electrical imaging. Procs. 6th Meeting of the European Association for
Environmental and Engineering Geophysics, 3-7 Sept. 1997, Bochum,
Germany, EL05.
Seaton, W.J. and Burbey, T.J., 2000. Aquifer characterization in the Blue
Ridge physiographic province using resistivity profiling and borehole
geophysics : Geologic analysis. Journal of Environmental &
Engineering Geophysics, 5, no. 3, 45-58.
Silvester P.P. and Ferrari R.L., 1990, Finite elements for electrical engineers
(2nd. ed.) . Cambridge University Press.
54
Slater, L., Binley, A.M., Zaidman, M.D. and West, L.J., 1997, Investigation of
vadose zone flow mechanisms in unsaturated chalk using crossborehole ERT. Proceedings of the EEGS European Section 3rd
Meeting, Aarhus, Denmark, 17-20.
Summer, J.S., 1976, Principles of induced polarization for geophysical
exploration. Elsevier Scientific Publishing Company.
Tong, L. and Yang, C., 1990, Incorporation of topography into twodimensional resistivity inversion. Geophysics, 55, 354-361.
Turnbull, J., 1986. A field and interpretation technique for resistivity surveying
over two dimensional structures. Unpubl. PhD thesis, Un. of
Birmingham, U.K.
Van Voorhis, G.D. Nelson, P.H. and Drake, T.L., 1973, Complex resistivity
spectra of porphyry copper mineralization. Geophysics, 38, 49-60.
White, R.M.S., Collins, S. and Loke, P., 2003. Resistivity and IP arrays,
optimised for data collection and inversion. Exploration Geophysics,
34, 229-232.
Witherly, K.E. and Vyselaar, J, 1990, A geophysical case history of the Poplar
Lake Copper-Molybdenum deposit, Houston Area, British Columbia.
in Fink, J.B., McAlister, E.O., Sternberg, B.K., Wieduwilt, W.G. and
Ward, S.H. (Eds), 1990, Induced polarization : Applications and case
histories : Investigations in Geophysics No. 4, Soc. Expl. Geophys.
55
Figure 13 : (a) Arrangement of the electrodes for the dipole-dipole array. (b)
Example of dipole-dipole array with non-integer n value. Arrangement of the
electrodes for (c) the forward and (d) reverse pole-dipole arrays.
The distance, a, between the two current electrodes, C1 and C2, is the same as
that between the potential electrodes. The distance between the current
electrode C1 and the potential electrode P1 (the dipole separation factor) is
usually an integer multiple, n, of the distance between the current or potential
electrode pair. Initially, the dipole separation factor (n) is set to 1. Then it is
increased to 2, 3 and so on until a maximum value of between 4 and 6. When
the dipole separation factor is increased, the potential measured between P1
and P2 decreases rapidly with increasing n. For this reason, it is not advisable
to use a value of n greater than 6. Using larger values of n could result in rather
noisy data. In some surveys, the distance (a) between the current and potential
56
57
assumes that the x-location of C1 electrode is less than that of the P1 and P2
potential electrode pair (on the left side in Figure 13c). If the location of the
first electrode is given in the input data file, then the location of the C1
electrode is used.
The pole-dipole array is an asymmetrical array, and over symmetrical
structures the apparent resistivity anomalies in the pseudosection are also
asymmetrical. In some situations, the asymmetry in the measured apparent
resistivity values could influence the model obtained after inversion. One
method to eliminate the effect of this asymmetry is to repeat the measurements
with the electrodes arranged in the reverse manner (Figure 13d). By combining
the measurements with the forward and reverse pole-dipole arrays (Figures
13c and 13d), any bias in the model due to the asymmetrical nature of this
array would be removed. The file PDIPREV.DAT is an example field data set
that combines measurements made with the forward and reverse poledipole arrays. For the reverse pole-dipole measurement, the location of the first
electrode is given by the position of the P2 electrode. A negative value for the
n factor is used to indicate that the reverse pole-dipole arrangement is used.
In this program, the maximum allowed dipole separation factor n is 32 while
the largest spacing between the P1-P2 electrode pair is 16 times the unit
electrode spacing for the dipole-dipole array. For the pole-dipole array, n can
have a maximum value of 48 while the P1-P2 spacing can be up to 32 times the
unit electrode spacing. In most cases, the n dipole separation factor is an
integer value. However it is possible for the n factor to have non-integer values
although all the electrodes still have a constant inter-electrode spacing. This
can occur when the spacing a between the C1-C2 pair is twice (or more) the
unit electrode spacing. For the example shown in Figure 13b, the unit electrode
spacing for the survey line is 1 metre. The a spacing has a value of 2 metres,
while the distance between the C1 and P1 electrodes is 3 metres. In this case,
the n factor has a value of 1.5. The data file, DIPOLEN5.DAT, gives an
example of a dipole-dipole data set with non-integer n values. For cases where
the fractional part of the n factor has is an infinite series in decimal notation,
the n value should be given to at least four decimal places. For example, if the
n value is one and one-third, it should be given as 1.3333.
58
Figure 14 : The steps used by the (a) Wenner and the (b) WennerSchlumberger arrays to increase the depth of investigation.
The apparent resistivity value for the Wenner-Schlumberger array is given by
= pi n (n+1) a R
where R is the measured resistance, a is the spacing between the P1 and P2
electrodes and n is the ratio of the distances between the C1-P1 and the P1-P2
electrodes. This array effectively becomes the Schlumberger array when the n
factor is greater than 2. Thus it is actually a combination of the Wenner and
Schlumberger arrays adapted for use for an arrangement with a line of
electrodes with a constant spacing (as normally used in 2-D electrical imaging).
Besides better horizontal coverage, the maximum depth of penetration of this
array is about 15% larger than the Wenner array. Note that the normal Wenner
array is actually a special case of the Wenner-Schlumberger array where the n
factor is equals to 1.
In practice, since the potential between the P1 and P2 electrodes decreases
when the electrode spacing factor n is increased, the maximum value of n used
in actual field surveys is about 8. To increase the depth of investigation, the
spacing between the P1-P2 electrodes is increased to 2a and the measurements
59
60
|
|
|
|
|
|
|
|
|
|
|
|
|
Topography flag
Number if regions to fix, put 0 if none
Type of first region, R for rectangular
X and Z coordinates of top-left corner of rectangle
X and Z coordinates of bottom-right corner of rectangle
Resistivity value of rectangular region
Damping factor weight
Type of second region, T for triangular
X and Z coordinates of first corner of triangle
X and Z coordinates of second corner of triangle
Coordinates of third corner of triangle
Resistivity value of triangular region
Damping factor weight
The first item after the topography data section is the number of regions where
the resistivity is to be specified. In the example above, 2 regions are specified.
If a value of 0 is given (default value), then there are no regions where the
resistivity is specified by the user. Next, the shape of the region is given, R for
rectangular or T for triangular. If a rectangular region is specified, then the X
and Z coordinates of the top-left and bottom-right corners of the rectangle are
given, as shown in Figure 16.
If a triangular region is chosen, the X and Z coordinates of the 3 vertices of the
triangle must be given in an anti-clockwise order. After the coordinates of the
region to be fixed are given, the next data item is the resistivity of the region.
After that, the damping factor weight for the resistivity of the region is needed.
This parameter allows you control the degree in which the inversion subroutine
can change the resistivity of the region. There is usually some degree of
uncertainty in resistivity of the region. Borehole measurements can only give
the resistivity of a very limited zone near the borehole. Thus, it is advisable that
the program should be allowed (within limits) to change the resistivity of the
region. If a damping factor weight of 1.0 is used, the resistivity of the region is
allowed to change to the same extent as other regions of the subsurface model
61
The larger the damping factor weight is used, the smaller is the change that is
allowed in the resistivity of the "fixed" region. Normally, a value of about 1.5
to 2.5 is used. If a relatively large value is used, for example 10.0, the change
in the resistivity of the region would be very small during the inversion
process. Such a large value should only be used if the resistivity and shape of
the region is accurately known.
62
Comments
| Title
| The unit electrode spacing
| Array number 8 for this array
| The spacing b between the C1-C2 pair
| The number of data points
| Flag for mid-point of array
| No IP data
| x-location, spacing a, app. resis.
| Repeat for all the other points
Note that for this array, it is necessary to include the spacing b between the C1C2 electrodes pair after the array number.
63
Figure 18 : Three possible situations for underwater surveys, and a survey with
floating electrodes.
In the first situation, there is a water layer with a constant thickness over a flat
sediment surface (i.e. there is no topography). An example of such a data set is
given in the file WATER.DAT. The bottom section of this file with comments
is as follows :WATER.DAT file
39.00
1.00 16
51.36
40.00
1.00 16
52.09
41.00
1.00 16
54.29
0
0
1
50.00, -100.00, 200.00
4.00
Comments
| Last 3 data points
|
|
| 0 for no topography
| 0 for no fixed regions
| 1 to indicate water layer present
| Resistivity of water layer, left and right
| limits of water layer
| Thickness of water layer
64
While the left and right limits of the water layer are included in the data format,
this is at present not used by the program. It is included for future use for
surveys with some of the electrodes above the water layer, for example a
survey across a river. Note that a flag is included to indicate that the normal
geometric factor (as used for a surface survey) is used to calculate the apparent
resistivity values. If a value of 0 is used for this flag, the exact geometric factor
(which includes the thickness of the water layer) must be used to calculate the
apparent resistivity values. For actual field surveys, it is expected that the
normal surface geometric factor will be used.
If the river or sea bottom has topography, the topography information is
entered immediately after the data set as in a normal land surface survey. The
bottom section of the files is as follows :Underwater survey file
wth topography
39.00
40.00
41.00
2
1.00 16
1.00 16
1.00 16
51.36
52.09
54.29
7
0.0, 3.0
10.0, 4.0
15.0, 4.5
25.0, 5.0
30.0, 5.1
35.0, 4.5
45.0, 4.6
1
0
1
50.00, -100.00, 200.00
4.00
1
Comments
| Last 3 data points
|
|
| 2 for topography with surface x| distances
| Number of topography data points
| The x-location and elevation of each
| topography data point
|
|
|
|
|
| To indicate 1st electrode is at 1st topo point
| 0 for no fixed regions
| 1 to indicate water layer present
| Resistivity of water layer, left and right
| limits of water layer
| Elevation of water surface with respect to
| local datum
| 1 to indicate normal surface geometric factor
| used
The program will automatically calculate the thickness of the water layer from
the elevation of the sea or river bottom and the elevation of the water surface.
Note that this format also allows for the third possible situation shown in
Figure 18 where some of the electrodes are above the water surface (i.e. on
65
normal dry land) and some of the electrodes underwater. In the example above,
the electrodes between 0 and 10 meters are above the water surface. A common
situation where this occurs is a survey that crosses a river. In this case, the
program will assume that an electrode with an elevation that is less than the
elevation of the water surface is underwater. For the case when some of the
electrodes are above the water surface, the surface geometric factor must be
used for calculating the apparent resistivity values for all the data points.
The topographic modelling is automatically carried out by the program when
you invert the data set. The program will automatically adjust the surface of the
finite-element grid used to model the subsurface so that it matches the surface
of the sediment below the water layer.
There is a fourth possible situation with a confined body of water that is so far
not supported. One possible situation is a river or lake with dykes. In this case,
some points with elevations below the water surface level are not underwater.
Support will probably be added in the future when such situations are more
frequently encountered.
Many underwater surveys are carried out by dragging a cable or streamer
behind a boat. In this case, the electrode locations are unlikely to be equally
spaced. This situation is best handled by entering the data in the general array
format that is described in Appendix L. The data file LAKELELIA.DAT is an
interesting field survey by Technos Inc. with data in the general array format
(Appendix L) and underwater topography. Parts of the file are highlighted
below to illustrate the data format used.
LAKELELIA.DAT file
Comments
66
2
38
26.12 999.09
30.48 999.09
.
.
1127.76 999.09
1
0
0
1
58.00,-2000.00,2000.00
1000
1
0,0,0
Figure 19 shows the apparent resistivity pseudosection and inversion model for
this data set. Mobile surveying systems typically produce survey lines that are
very long compared to the depth of investigation of the cable array system
used.
Surveys with floating electrodes
Another possible arrangement for a survey using a boat dragging a cable is
where the electrodes are floating on the water surface. The main disadvantage
of this arrangement is that a large part of the current flows within the water
layer, compared to the portion of the current that flows into the material below
the water bottom. The main advantage is that it is easier and faster to carry out
and avoids problems such as the cable being snagged by obstacles on the river
bottom. It could be an efficient method in shallow areas where the screening
effect due to the water layer is not too large. One possible way of interpreting
such a data set is to treat it as a standard surface data set where the water layer
is included as part of the model. This probably gives acceptable results where
there is a strong contrast between the water layer and the topmost layer of the
sub-bottom materials, and where the data has a low noise level. However if the
depth of the water bottom was measured during the course of the survey
(usually with an echo sounder), and the water resistivity was also measured, the
effect of the water layer could be calculated and included in the model. The file
WATER_FLOAT.DAT is a synthetic data set which gives an example of the
data format. The initial part of the file is identical with that used for normal
67
surface surveys or surveys with electrodes on the water bottom. The difference
is in the final section of the file where the water layer parameters are given.
WATER_FLOAT.DAT file
Comments
While the above example gives the data in the general array format (Appendix
L), the program can also accept data in the index based format. For example,
the above data set is for the dipole-dipole array. An index based format (see
Appendix A) will give the location of the data point, the a dipole length and
the n dipole separation factor.
68
69
There are two methods that can be used to invert data collected with floating
electrodes. The first method is similar to that used for surveys with electrodes
on the bottom where the resistivity of the water is fixed and the model is
extended below the water layer bottom. The second method incorporates the
water layer into the inversion model. The two methods can be selected using
the Inversion Inversion Methods and Settings Floating electrodes survey
inversion method option.
70
The first method (Use fixed water layer) is more suitable when the maximum
thickness of the water layer is small (less than 20%) compared to the maximum
depth of investigation of the survey configuration. Figure 20 below shows the
inversion of the WATER_FLOAT.DAT data set using this method. Note that a
distorted finite-element grid is used to model the water layer. The maximum
thickness of the water layer in this example is 2.5 metres which is small
compared to the maximum depth of investigation at about 15 metres for the
data set.
Figure 20. Inversion results of the WATER_FLOAT.DAT data set using the
first inversion method where the resistivity water layer (represented by the top
blue layer in the model section) is fixed and model extends from below the
water bottom.
In cases where the thickness of the water layer is significant, a second
inversion method (Incorporate the water layer into the model) is more suitable.
The water layer section is included into the inversion model. This method has
two inversion settings. In most cases, the resistivity of the water layer does not
vary significantly along the survey line or with depth. Thus normally the option
Minimise variation of water resistivity is selected. However to accommodate
cases where there are significant variations in the water resistivity (such as in a
mixing zone between fresh and saline water), the option Allow water layer
resistivity to vary freely can be used.
The subsurface material below the water layer frequently has a much higher
resistivity than the water. The option Select a sharp change across the water
bottom boundary can be used so that a sharp contrast is allowed between the
water layer and the subsurface. This option uses the method described in
Appendix T : Incorporating boundaries of known layers to create the sharp
change in the model resistivity. The program automatically adjusts the
thickness of the model layers and divides the model cells into those belonging
71
to the water layer and the subsurface. Figure 21 shows the arrangement of the
model cells for one of the survey lines along the So Francisco River, divisor
of Bahia (BA) and Pernambuco (PE) states, neighborhoods of the Santa Maria
da Boa Vista city (PE), northeast of the Brazil (Rodrigo Machado pers.
Comm.). In this survey, a dipole-dipole type of configuration was used with 5
metre dipoles. However, the readings were taken every metre which gives a
data set with a nominal unit electrode spacing of 1 metre. To reduce the
number of model cells, and taking in consideration that the resolution of such a
survey is very unlikely to be better than half the dipole length, the width of the
model cells were set at 3 times the unit electrode spacing, i.e. basically 3
metres for almost the entire section. Also note that the depth of the water at
some places is greater than maximum median depth of investigation (as
indicated by the data points markers). However, the program sets the depth of
the layers such that there is at least one model layer below the water bottom
(represented by the dark blue line). The cells below the water layer is marked
as light blue in the figure below. A sharp resistivity variation is allowed in the
inversion method used between the two sections.
Figure 21. Arrangement of model cells and the water bottom boundary.
The apparent resistivity pseudosection and inversion model for this data set is
shown in Figure 22. In this inversion, the resistivity variations within the water
layer was minimised. Thus the water layer resistivity is generally uniform
except towards the left end of the survey line where there is not much data.
There is also an indication that between the 190 and 220 metres marks, the
near-surface river bed material consists of low resistivity sediments.
72
Figure 22. Inversion model for the survey with floating electrodes along the
along the So Francisco River in Brazil. The thin black line indicates the water
bottom boundary.
Surveys with floating electrodes are frequently carried out using a cable with a
number of electrodes pulled behind a boat, usually with a multi-channel
resistivity-meter system controlled by a computer link to a GPS system. A 5
metres spacing between the electrodes takeouts is commonly used together a
dipole-dipole type of array configuration (not necessary symmetrical). The boat
is moving continuously and the measurements can be made at arbitrary
intervals although the dipole length is 5 metres. Frequently, the measurements
are digitized to every 1 metre position. Thus, the active electrode positions are
1 metre apart that is much smaller than the dipole length of 5 metres. This can
results in very long survey lines, and very large inversion models with the
default settings of the inversion program. A number of options have been
added to the program to reduce the inversion time for such data sets.
The resolution of the survey setup is unlikely to be very much better than the
dipole length particularly if there is water layer of significant thickness
between the cable and the subsurface. The program normally uses a model
where the width of the normal cells is set to be the same (or half) as the
distance between the electrode positions along the line. This is reasonable for
normal land surveys with a static cable setup. For floating electrodes survey,
since the distance between the electrode positions (1 metre) is much smaller
than the dipole length (5 metres), this results is a model that is too fine. To
avoid this, use the option under the Inversion Model Discretization
Change width of blocks menu. The following dialog box is displayed under
this option. Since the horizontal resolution of the data is unlikely to be better
than half the dipole length, it is recommended that the width of the model cells
be set at 3 times the unit electrode spacing (for the situation with 5 metres
dipoles and 1 metre data spacing). This will greatly reduce the number of
model cells in the inversion model.
73
The inversion time can be further reduced using the Inversion Inversion
Methods and Settings Fast inversion of long survey lines menu option which
will display the following dialog box.
74
The first option is to use an optimized method to calculate the Jacobian matrix.
This can significantly reduce the calculation time without affecting the
accuracy of the values, and should give the same inversion model as the default
method. The second method is to use a fast method to calculate the Jacobian
matrix. The Jacobian matrix values and thus inversion model will be slightly
different from that obtained using the standard method, but the difference is
normally small (less than 5%) and does not affect the model interpretation. The
third method, using sparse inversion techniques, is intended for even longer
survey lines of 1000 electrodes positions or more. This method will still
produce a contiguous model along the entire survey line, but takes advantage
of the sparsity of the matrices using in the inversion calculation to reduce the
number of calculations needed. Again the results will be marginally different
(usually less than 5%) form that obtained using the standard method but will
not affect the interpretation of the results. The use of all three methods can
reduce the inversion time to about one-quarter of that require using the
standard methods.
Most systems for surveys with floating electrodes digitize the electrode
positions to every 1 metre while the spacing between the electrodes takeouts in
the cable is 5 metres. This is probably too fine when the thickness of the water
layer is more than a couple of metres. A coarser discretization, such as to every
1.25 or 2.5 metres (i.e. one-quarter or half the spacing between the electrodes
takeouts), is probably sufficient. This has the advantage of reducing the
number of electrode positions in the inversion model, and consequently greatly
reducing the inversion time without significantly affecting the results. If the
data conversion program supplied with the survey system does not have an
option to change the data discretization interval, you can do so by changing the
unit electrode spacing value in line 2 of the data file (for example from 1.0 to
2.5). In this case, before reading in the data file, you must select the File
Round up positions of electrodes option which will display the following
dialog box.
75
Selecting the Sift the electrodes option will digitize the positions of the
measurements to the specified unit electrode spacing in the data file.
As a final note, it has been observed that in some data sets there is mismatch
between the coordinates of the electrodes for the measurements and the bottom
topography as measured using a profiler and a GPS system. This shows up
when using the option to incorporate the water layer in the inversion model by
a horizontal shift (usually of 5 to 10 metres) between the bottom topography
and steep structures in the inversion model such as small gullies and peaks.
This is probably due to differences in the locations of the depth sounder system
and the cable with the electrodes.
76
Comments
| Title
| Unit electrode spacing
| Array type
| Number of data points
| Location of centre of array given
| 1 to indicate IP present
77
Chargeability
msec
0.1,1.0
1.50 1.00 1
2.50 1.00 1
12.04
12.03
7.2038
7.1983
| Type of IP data
| IP unit
| Delay, integration time
| x-loc., a, n, app. res., app. IP
| 2nd data point
78
data set. In the seventh line, the type of IP data is given as Percent Frequency
Effect. The ninth data line contains the values of the low and high frequencies
used in the measurement. This data set is from a field survey in Burma where
the measurements were made with 20 metres and 40 metres dipoles (Edwards
1977). Like many field data sets, it has a very complex distribution of the data
points in the pseudosection. This is a relatively noisy data set. It is advisable to
use the option to Include smoothing of model resistivity values described in
section 9 for the inversion of this data set to avoid extremely large and small
model resistivity values. The survey target is a galena deposit in metasediments. The geology is rather complex with massive galena deposits
together with quartz veins, silicified marbles and clay zones. There is a very
wide range of resistivity values.
IP values are also given as phase angles. In this case the unit normally used is
milli-radians (mrad). An example of an IP data set with phase angles is given
in the file IPKENN.DAT with values from the paper by Hallof (1990). In the
seventh line, the type of IP data type is given as Phase Angle. The second
parameter in the ninth data line contains the values of the frequency at which
the phase angles were measured. The first parameter is not used and is
normally set to 0. Many modern IP survey instruments can measure the phase
angle for several frequencies. In this case, the inversion of is repeated for the
phase angle data at each frequency. This will give an idea of the change of the
subsurface IP phase angle with frequency for complex resistivity studies.
IP data is sometimes given as a metal factor (MF) value. The MF value can be
calculated from either time domain or frequency domain measurements. In the
time domain, the metal factor is value is given by
MF = 1000 M / DC
where the chargeability M is given in terms of millisecond (Witherly and
Vyselaar, 1990). In the frequency domain, it is given as
MF = 100000 (DC - AC) / AC 2
The file IPMAGUSI.DAT is from a survey over the Magusi River ore body
(Edwards 1977) where the survey was conducted with 30.5 metres (100 feet),
61.0 metres (200 feet) and 91.4 metres (300 feet) dipoles. Again the resulting
pseudosection has a very complex distribution of the data points. The measured
apparent resistivity and IP pseudosections, together with the model sections
obtained are shown in Figure 23. The ore body shows up as a distinct low
resistivity body with high IP values near the middle of the survey line in the
model sections. In the inversion of this data set, the robust inversion method
was used (see Appendix K) to sharpen the boundary between ore body and the
surrounding rocks.
79
The inversion program tries to minimise the difference between the observed
and calculated equivalent apparent chargeability values. IP values in percent
frequency effect and phase angles are directly proportional to the equivalent
chargeability values. However, the metal factor value also involves a resistivity
value. The model that gives a minimum RMS error for the chargeability values
sometimes does not give a minimum RMS error for the metal factor values.
However, the actual effect on the inversion model is usually very small.
Figure 23. Magusi River ore body (a) Apparent resistivity pseudosection, (b)
resistivity model section, (c) apparent metal factor pseudosection and (d) metal
factor model section.
80
Since the IVP files are created by the RES2DINV program, it is not necessary
for the user to deal with the details about the file format. To create them, the
user just needs to click the appropriate inversion options within the
RES2DINV program, and then select the Save inversion parameters option
under the Change Settings menu to save the parameters into an IVP file.
81
82
Comments
| Title
| Smallest electrode spacing
| Array number 12 for cross-borehole survey
| Number of data points
| 2 to indicate XYZ location format is used
| 0 for no IP data
| Header for surface electrodes
| Number of surface electrodes
| x- and z-location of first surface electrode
| location of second surface electrode
| Note location values are given for the
| electrodes in ascending order starting
| from the left.
| Note a zero value for the depth for the
| surface electrodes.
|
|
|
|
|
|
|
83
14.0, 0.0
15.0, 0.0
Borehole 1 Electrodes
10
4.0 1.0
4.0 2.0
4.0 3.0
4.0 4.0
4.0 5.0
4.0 6.0
4.0 7.0
4.0 8.0
4.0 9.0
4.0 10.0
Borehole 2 Electrodes
10
11.0 1.5
11.0 2.5
11.0 3.5
11.0 4.5
11.0 5.5
11.0 6.5
11.0 7.5
11.0 8.5
11.0 9.5
11.0 10.5
Measured Data
3 0.00 0.00 1.00 0.00
3 0.00 0.00 2.00 0.00
3 0.00 0.00 3.00 0.00
3 0.00 0.00 4.00 0.00
3 0.00 0.00 5.00 0.00
3 0.00 0.00 6.00 0.00
3 0.00 0.00 7.00 0.00
3 0.00 0.00 8.00 0.00
2.00
3.00
4.00
5.00
6.00
7.00
8.00
9.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
|
|
| Header for first borehole
| Number of electrodes in first borehole
| x- and z-location of first electrode
| x- and z-location of second electrode
| Note locations of electrodes
| are given from the topmost electrode
| below the surface.
| Also note a constant x-location for
| vertical borehole.
|
|
|
| Header for second borehole
| Number of electrodes in second borehole
| x- and z-location of first electrode
| location of other electrodes are then given.
|
|
|
|
|
|
|
|
| Header for section with the measurements
101.5718 | The format for each data point is :99.5150 | Number of electrodes used in
99.2303 | measurement, x- and z-location of
99.1325 | C1 electrode, x- and z-location of
101.0616 | P1 electrode, x- and z-location of
105.7333 | P2 electrode, apparent resistivity
112.6745 | value.
118.5223 |
The array number is 12 for cross-borehole survey data with the measurements
given as apparent resistivity values. You can also enter the data as resistance
measurements, in which case the array number is 13. This might be more
convenient as most resistivity meters give the readings as a resistance value in
ohm, and furthermore the geometric factor for arrays with subsurface
electrodes is different from the geometric factor for conventional surface
arrays. The file BORERES.DAT gives an example where the measurements
are given as resistance values. An interesting field data set where the pole-pole
array was used, and the measurements are also given as resistance values, is
BORELUND.DAT from Lund University, Sweden.
84
85
which also contains IP measurements). However, if all four electrodes are used,
the x- and z-locations of the C1, C2, P1 and P2 electrodes must be given in this
order. You can combine measurements made with different numbers of
electrodes in the same data file.
When the programs reads in a file with resistance values, you have a choice of
inverting the data set using apparent resistivity values, or directly use the
resistance values. Using resistance values directly in the inversion has the
advantage of allowing you to use readings where the apparent resistivity value
does not exist, or is negative. After reading in a data file, the program will
attempt to filter out suspicious readings with potentially high noise levels if the
measurements are given as apparent resistivity values, or if you had chosen the
option to use apparent resistivity values in the inversion. If you choose to carry
out the inversion using resistance values, the readings are not filtered.
The geometric factor for subsurface electrodes is different from that used for
surface electrodes. As an example, the geometric factor for a measurement
where only two electrodes is used is as follows. If the C1 and P1 electrodes are
located at (x1,z1) and (x2,z2) respectively, the geometric factor k is then given by
k = 4 pi /(1/r1 + 1/r1')
where
r1 = sqrt (dx2 + dz2)
dx = x1 - x2
Dz = z1 + z2
86
electrodes were not used in the field survey, just insert dummy electrodes into
the data file to satisfy the requirements of this program.
By default, the program will subdivide the subsurface into quadrilateral blocks
such that the dimensions of the blocks are equal to the spacing between the
electrodes (Figure 24a). However, you can also choose to use a model where
the dimensions of the blocks is about half the spacing between the electrodes
(Figure 24b). Using the model with a finer discretization could significantly
improve the inversion results in some cases (Sasaki 1992). To select the type of
model to use, click the Change Settings options on the Main Menu top bar,
followed by Type of cross-borehole model. In theory, it is possible to further
subdivide the subsurface into even smaller blocks. However, since the
resolution of electrical measurements decreases rapidly with distance from the
measuring electrodes, this is unlikely to significantly improve the results. In
fact, it could result in unnatural oscillations in the model resistivity values,
particularly near the electrodes. This is as a result of the well known trade-off
between model resolution and model variance in geophysical inversion.
Figure 25 shows the model obtained after the inversion of the
BOREHOLE.DAT data set. This is a synthetic data set produced by a forward
modelling program with a high resistivity block in between the two boreholes.
The option to use finer blocks with half the size of the spacing between the
electrodes was used in the inversion of this data set.
Figure 26 shows the inversion results from an interesting field data set. This
data set is one from a number that were collected by a survey to study the flow
of fluids through the UK Chalk aquifer in east Yorkshire by using a saline
tracer (Slater et al 1997). There is a low resistivity zone near the surface where
the saline solution was irrigated onto the ground, and also prominent low
resistivity zones below a depth of 7 metres due to the saline tracer that had
flowed downwards. Another interesting feature of this data set is that no
surface electrodes were used. So all the surface electrodes given in the
BORELANC.DAT data file are dummy electrodes; two to the left of borehole
1 and another two to the right of borehole 2.
If IP measurements were also made, you need to enter a value of 1 at the 6th
line in the data file, and two more data lines after that which gives the type of
IP measurement used and the two parameters associated with it (see Appendix
F). Next, enter the IP value after the apparent resistivity value for each data
point. The file BOREHIP.DAT is an example cross-borehole data file with IP
measurements.
87
Figure 25. The model obtained after the inversion of the BOREHOLE.DAT
data set. The option to use finer blocks with half the size of the spacing
between the electrodes was used.
Figure 26. Model obtained from the inversion of data from a cross-borehole
survey to map the flow of a saline tracer in between two boreholes. Note the
low resistivity zones near the surface (where the tracer was injected) and below
a depth of 7 metres. The locations of the borehole electrodes are shown by
small black dots.
88
The boreholes_time_2D.dat example data file shows the data format for 2-D
time-lapse borehole data. The format is similar to that used for normal surface
surveys. The data section with the time-lapse header is given directly after the
section with the borehole information, and immediately before the apparent
resistivity data. The inversion options for borehole time-lapse data are set the
same way as for normal surface surveys using the same menu options.
The following table shows part of the data file with the time-lapse information.
boreholes_time_2D.dat
Comment
----------------------------------------------------------------44.000, 64.000
Time sequence data
The file boreholes_inclined.dat gives an example of the data format with nonvertical boreholes. Note the addition of an additional header line Inclined
boreholes present just before the section with the positions of the boreholes to
indicate that non-vertical boreholes are present. For inclined boreholes, the
subdivision of the subsurface into model blocks is no longer tied directly to the
positions of the electrodes. You can also use this format for vertical boreholes
are where the corresponding electrodes at different boreholes are at different
depths. This avoids inclined or skewed model blocks when there are significant
differences in the borehole electrodes depths.
The RES2DINV program supports up to 10 boreholes (20 boreholes if your
computer has at least 256 MB RAM) along a survey line. This limit might be
increased in future when the need arises. A possible situation where more than
2 boreholes exists is when a current electrode is placed at the end of a
borehole driller or penetrometer. The file BOREHOLE3.DAT gives an
example of the data format with more than 2 boreholes. A description of the
format is as follows.
89
BOREHOLE3.DAT file
Comments
--------------------------------------------------------------------------------------------Pole-dipole borehole test
1.0
12
908
2
0
Surface Electrodes
16
0.0, 0.0
1.0, 0.0
2.0, 0.0
3.0, 0.0
4.0, 0.0
5.0, 0.0
6.0, 0.0
7.0, 0.0
8.0, 0.0
9.0, 0.0
10.0, 0.0
11.0, 0.0
12.0, 0.0
13.0, 0.0
14.0, 0.0
15.0, 0.0
Number of boreholes
3
Borehole 1 Electrodes
11
4.0 1.0
4.0 2.0
4.0 3.0
4.0 4.0
4.0 5.0
4.0 6.0
4.0 7.0
4.0 8.0
4.0 9.0
4.0 10.0
4.0 11.0
Borehole 2 Electrodes
11
11.0 1.0
11.0 2.0
11.0 3.0
11.0 4.0
11.0 5.0
11.0 6.0
| Title
| Smallest electrode spacing
| Array number 12 for cross-borehole survey
| Number of data points
| 2 to indicate XYZ location format is used
| 0 for no IP data
| Header for surface electrodes
| Number of surface electrodes
| x- and z-location of first surface electrode
| location of second surface electrode
| Note location values are given for the
| electrodes in ascending order starting
| from the left.
| Note a zero value for the depth for the
| surface electrodes.
|
|
|
|
|
|
|
|
|
| New header for more than 2 boreholes
| Number of boreholes here
| Header for first borehole
| Number of electrodes in first borehole
| x- and z-location of first electrode
| x- and z-location of other electrodes
|
|
|
|
|
|
|
|
|
| Header for second borehole
|
|
|
|
|
|
|
90
11.0 7.0
|
11.0 8.0
|
11.0 9.0
|
11.0 10.0
|
11.0 11.0
|
Borehole 3 Electrodes
|Header for third borehole
11
|
13.0 1.0
|
13.0 2.0
|
13.0 3.0
|
13.0 4.0
|
13.0 5.0
|
13.0 6.0
|
13.0 7.0
|
13.0 8.0
|
13.0 9.0
|
13.0 10.0
|
13.0 11.0
|
Measured Data
| The apparent resistivity values start after this
3 0.00 0.00 1.00 0.00 2.00 0.00 101.5718
| Note 3 electrodes for
3 0.00 0.00 2.00 0.00 3.00 0.00 99.5150
| a pole-bipole array
.
.
3 11.00 11.00 11.00 5.00 11.00 4.00 110.7175
| Last two data
3 11.00 11.00 11.00 4.00 11.00 3.00 118.4761
| points
0,0,0,0,0
| End with 5 zeros
Note that the format is essentially the same as that used earlier for two
boreholes, except for the header after the list of surface electrodes and the
value for the number of boreholes.
The file BOREHOLE_TOPO.DAT is a field example of a cross-borehole data
set with topography. The initial part of this data file with a description of the
format is as follows.
91
BOREHOLE_TOPO.DAT file
Comments
92
93
geometric factor that takes into account the positions of the C2 and P2
electrodes can be used.
Approximate Geometric factor (ideal pole-pole array) = 2.pi.r1
Exact Geometric factor = 2 pi / [ (1/r1) - (1/r2) - (1/r3) + (1/r4) ]
The program supports both conventions.
A possible arrangement of the electrodes in a pole-pole survey is shown in
Figure 28. In this case, the C2 and P2 electrodes are fixed throughout the
survey. The measurements are made by using different pairs of electrodes
along the survey line as the C1 and P1 electrodes. For a survey line with n
electrodes, there are n(n+1)/2 possible combinations. For example, if there are
25 electrodes in the survey line, there are 300 possible combinations. In
practice, not all the possible measurements are made. Instead a maximum
distance between the C1 and P1 electrodes is set depending on the maximum
depth of investigation needed (Edwards 1977). In many cases, this maximum
distance is 6 to 10 times the unit electrode spacing along the survey line. To
avoid the possibility of negative or zero apparent resistivity values, the distance
of the C2 and P2 electrodes must be at least 2.5 times (and preferably 3 times)
the maximum C1 to P1 spacing used. For example, if the unit electrode spacing
is 1 metre, and the maximum C1-P1 spacing is 10 metres, then the C2 and P2
electrodes must be at least 25 metres from the survey line. Note that as the
distance of the C2 and P2 electrodes from the survey line decreases, the
effective maximum depth of investigation of the survey also decreases. It might
be significantly less than the depth of investigation for the ideal pole-pole array
(Edwards 1977).
94
2.00
10.13
3.00
2.00
10.18
Comments
| Title
| Smallest electrode spacing
| Array number 2 for pole-pole.
| Header to indicate position of remote
| electrodes included in data file
| Header for second current electrode location
|
| x-, y- and z-location of C2 electrode
| Header for second potential electrode
| location
| x-, y- and z-location of P2 electrode
| Type of geometric factor used
| Number of data points
| 1 to indicate x-location of centre of array is
| given
| 0 for no IP
| The x-location, electrode spacing
| apparent resistivity for first data point
| Second data point
The data format is the same as that for normal pole-pole surveys except for the
section (after the array number) which contains information about the location
of the second current and potential electrodes. The data line Exact Geometric
factor used is used to indicate that the apparent resistivity values in the data
file were calculated used the exact geometric factor. If the approximate
geometric factor was used, this data line should be given as Approximate
Geometric factor used. The file POLDPLFA.DAT is an example data file for
a pole-dipole survey where the approximate geometric factor was used in
calculating the apparent resistivity values. Note that in this file, only the
location of the second current electrode C2 is given.
For the pole-pole array, the effect of the C2 electrode is approximately
proportional to the ratio of the C1-P1 distance to the C2-P1 distance. If the
effects of the C2 and P2 electrodes are not taken into account, the distance of
these electrodes from the survey line must be at least 20 times the largest C1-
95
P1 spacing used to ensure that the error is less than 5%. In surveys where the
inter-electrode spacing along the survey line is more than a few metres, there
might be practical problems in finding suitable locations for the C2 and P2
electrodes to satisfy this requirement. Thus the error in neglecting the effects of
the remote electrodes is greatest for the pole-pole array. As a general guide, if
the distances of the C2 and P2 electrodes from the survey line is more than 20
times the largest C1-P1 spacing used, the array can be treated as an ideal polepole array for interpretation purposes. Otherwise, the coordinates of the C2 and
P2 electrodes should be recorded so that their effects can be determine by this
program. However, it should be noted that as the distance of the P2 electrode
from the survey line increases, the telluric noise picked up by the P1-P2 pair
also increases. This factor should also be taken into account when positioning
the P2 electrode.
For the pole-dipole array, the effect of the C2 electrode is approximately
proportional to the square of ratio of the C1-P1 distance to the C2-P1 distance.
Thus the pole-dipole array is less affected by the C2 remote electrode. If the
distance of the C2 electrode is more than 5 times the largest C1-P1 distance
used, the error caused by neglecting the effect of the C2 electrode is less than
5% (the exact error also depends on the location of the P2 electrode for the
particular measurement). So, as a general guide, if the distance of C2 electrode
from the survey line is more than 5 times the largest C1-P1 spacing, it can be
treated as an ideal pole-dipole array. Otherwise, enter the coordinates of the C2
electrode into the data file.
96
97
A field example with sharp boundaries was shown earlier in Figure 23 for the
Magusi River resistivity and IP data set. The main structure, the massive
sulphide ore body, by nature has a distinct and sharp resistivity/IP contrast with
the surrounding igneous/metamorphic country rocks.
In the RES2DINV program, this robust model option can be selected by
clicking the Robust model constrain option in the Select robust inversion
dialog box. There is a cut-off factor which controls the degree in which this
robust model constrain is used. If a large value is used, for example 1.0, the
result is essentially that of the conventional smoothness-constrained leastsquares inversion method. If a very small value is used, for example 0.001, the
result is close to the true robust constrained inversion method.
98
Figure 30. Some possible non-conventional arrays. (a) Non-symmetrical fourelectrode Wenner-Schlumberger type of array. (b) Dipole-dipole array with
dipoles of unequal size. (c) A possible but probably non-viable electrode
configuration.
One possibility is a non-symmetrical variation of a symmetrical array, such as
the Wenner-Schlumberger or the dipole-dipole array (Figures 30a and 30b).
Such a configuration could arise from surveys with multi-channel resistivity
meters where measurements are made with several pairs of potential electrodes
for a common pair of current electrodes.
While the program gives the user greater latitude in the electrode arrangement,
some arrays that are technically possible but would have very low potential
signals should be avoided.
To accommodate the various possibilities, a data format which is similar to that
used for cross-borehole surveys (Appendix I) is used. The x-location as well as
the elevation of all the electrodes used in a measurement must be given. The
file MIXED.DAT is an example data file with such a format. This is actually a
synthetic data set with a mixture of measurements using the Wenner-
99
Schlumberger and dipole-dipole arrays. The initial part of this data file with
comments about the format is given below.
MIXED.DAT file
Comments
Mixed array
| Title
1.0
| Unit electrode spacing
11
| Array type (11 for general array)
0
| Sub-array type
Type of measurement (0=app. resistivity,1=resistance)
| Header
0
| 0 here to indicate apparent resistivity values
407
| Number of data points
1
| Indicator for type of x-location
0
| No IP values, 1 if I.P present
4 0.00 0.00 3.00 0.00 1.00 0.00 2.00 0.00 10.158 | The format for each data point is
4 1.00 0.00 4.00 0.00 2.00 0.00 3.00 0.00 10.168 | Number of electrodes used in
4 2.00 0.00 5.00 0.00 3.00 0.00 4.00 0.00 10.184 | measurement, x- and z-location of
4 3.00 0.00 6.00 0.00 4.00 0.00 5.00 0.00 10.225 | C1 electrode, x- and z-location of
4 4.00 0.00 7.00 0.00 5.00 0.00 6.00 0.00 10.337 | C2 electrode, x- and z-location of
4 5.00 0.00 8.00 0.00 6.00 0.00 7.00 0.00 10.708 | P1 electrode, x- and z-location of
4 6.00 0.00 9.00 0.00 7.00 0.00 8.00 0.00 11.668 | P2 electrode, apparent resistivity
4 7.00 0.00 10.00 0.00 8.00 0.00 9.00 0.00 12.542 | or resistance value.
The sub-array type indicator is used when the electrode configuration follows
one of the conventional arrays, for example the Wenner-Schlumberger array.
As an example, the file MIXEDWS.DAT has the data for a WennerSchlumberger array only but the information is arranged in a general array
format. In this case the sub-array number is 7. The file RATHCMIX.DAT has
the data for the Rathcrogan mound (described earlier in Figure 8) for the
Wenner array but in a general array format (thus it has sub-array number of 1).
For these data sets, the apparent resistivity vales can be displayed in the form
of a pseudosection. The file MIXED.DAT is a combined data set with a
mixture of measurements with the Wenner-Schlumberger and dipole-dipole
array. In this case, there is no consistent array type, so the sub-array number is
given as 0.
Concerning the indicator for the type of x-location, there are two possible
values. A value of 1 is used if the x-location values are the true horizontal
distances, while a value of 2 is used if it is the distance along the ground
surface. This is similar to the convention used for topography data (Section 7).
In the RATCMIX.DAT file, the topography information is included as the
elevation for each electrode in every data line. In some cases, it might be more
convenient to enter the topography information in a separate list, much like for
data in the normal format. One example with data in the general array format
but with the topography in a separate list after the apparent resistivity data lines
is given in the file ITALY_CAVE.DAT. Part of the file is shown below.
100
ITALY_CAVE file
Comments
Note the addition of a header line Topography in separate list that indicates
the topography information is in a separate list after the apparent resistivity
data lines. Note also in the data lines, the elevation for each electrode is given
as 0.00. The program will calculate the elevation for the electrodes from the
topography information.
The measurement can be given in terms of resistance or apparent resistivity. If
there is no topography, i.e. the z-locations are all equal to zero or the same, the
conventional formula can be used to calculate the apparent resistivity. The
geometric factor k is given by the following equation
k = 2 pi / (1/r1 - 1/r2 - 1/r3 + 1/r4)
101
In the case where the ground surface has a constant slope, both conventions
will give the same geometric factor.
Note that in the general array data format, the z-location is the elevation of the
electrode which is positive in the upwards direction. This unfortunately is
different from the format for the borehole data set where the z-values are
positive in the downwards direction.
Figure 31 shows an interesting arrangement where the electrodes are arranged
such that the true horizontal distances between adjacent electrodes are
constant. When the slope of the ground surface is not constant, this results in an
arrangement where the distance between adjacent electrodes as measured along
the ground surface is not constant but depends on the slope. In areas where the
slope is steeper, the distance between adjacent electrodes along the ground
surface is greater. To accommodate such an arrangement, the general array
format can be used. In this case, the indicator for the type of x-location must be
1 since the true horizontal distances are given in the data. Very often, the
survey is carried out with one of the conventional arrays, such as the WennerSchlumberger, so the appropriate sub-array number should also be given.
102
Figure 31. Arrangement of the electrodes along a survey line such that the true
horizontal distance between adjacent electrodes is constant regardless of the
slope of the ground surface. Note that the distance between adjacent electrodes
along the ground surface is greater at the steeper part of the slope.
In some cases, the 2-D data set is generated from a series of collinear 1-D
sounding lines. In such a situation, the distance between adjacent electrodes is
not constant, whether as measured along the surface or in the true horizontal
direction. For such a case, the general array format (with a sub-array type of 0)
can be used.
For data sets with a sub-array type of 0, the data cannot be displayed in the
form of a pseudosection, nor can it edited with the "Exterminate bad data
points" option. To remove bad data points from the data set, you need to first
carry out an inversion of the entire data set. However, you need to use the
"Robust data constrain" (see Appendix K) to ensure that bad data points do not
have a large effect on the inversion results. Next, go to the "Display" window
and read in the file with the inversion results. Select the "RMS error statistics"
sub-option under the "Edit data" menu. This will display a histogram where the
data points are grouped according to the difference between the measured and
calculated apparent resistivity values. This allows you to remove the data
points where a large difference occurs, for example more than 100 percent.
After removing the more noisy data points, save the trimmed data set in a file
and carry out the inversion again with the trimmed data set.
The suboption "Generate model blocks" under the "Inversion" option on the
main menu allocates the arrangement of the blocks in the model using the
sensitivity values as a guide. Figure 32 shows the sensitivity values of the
MIXEDWS.DAT data set using the default extended model, and for the
"Generate model blocks" option. Note that this option increases the width of
the blocks near the sides in the deeper parts of the model section in order to
increase the sensitivity values of the blocks. This option can also be used for
103
normal data sets with the standard arrays. By default, the program uses a
heuristic algorithm partly based on the position of the data points to generate
the size and position of the model blocks. The "Generate model blocks" uses a
more quantitative approach based the sensitivity values of the model blocks.
However, in practice, the simpler and faster heuristic algorithm gives
reasonably good results for most data sets.
Figure 32. The arrangement of the model blocks used by the program for the
inversion of the MIXEDWS.DAT data set using (a) the default extended model
and (b) a model generated so that any single block the does not have a relative
sensitivity value that is too small.
104
Figure 33. Arrangement of the electrodes for the Wenner alpha, beta and
gamma arrays.
105
The Wenner beta array is a special case of the dipole-dipole array where the
"n" factor is always 1. The RES2DINV program will automatically convert a
Wenner beta array data file into a dipole-dipole array data set.
The Wenner gamma array is not frequently used but it has direct support in
RES2DINV. The file GAMMA.DAT is an example data file for this array. A
case history of a field survey in Africa using this array is given in section 18 of
this manual.
106
In this dialog box, you can select the iteration number for which you want to
save the inversion results. Also, you can choose to save the resistivity values
directly, or the logarithm of the resistivity values which might be more suitable
if the resistivity values have a large range. SURFER will plot the sections as a
rectangular section. In many cases, especially a model section with topography,
this might not be appropriate. To remove the sections outside of the model
section, SURFER provides two methods of blanking part of the displayed
contoured section. The default and normally better method is to use the Base
107
Map Overlay feature in SURFER. In the bottom half of the dialog box, all the
various possible data or model sections are displayed. For a particular inversion
file, not all the possible sections are available. For example, the
RATHCRO.INV file does not have IP data, so the circles to the right of the
dialog box are not checked. As an exercise, click the 'Model resistivity with
topography' option for the RATHCRO.INV file. After clicking the OK button,
the program will then save the various sections. For a particular section, the
program will save 5 different files that are used for different functions in
SURFER. As an example, follow the following steps to plot the resistivity
(logarithm) model section with topography for the RATHCRO.INV file. The
different files are provided in the RES2DINV software package.
1). Create contour file. Click 'Grid' on the top menu bar, and then 'Data' to read
in the RATCHRO_TOPRESLOG.DAT file. After reading in the data file,
SURFER will show the 'Scattered Data Interpolation' dialog box. In the 'Grid
Line Geometry' section, the number of lines that SURFER uses to interpolate
the data values into a rectangular grid is shown. For this data set, the default
values are probably 50 lines in the X direction and 6 lines in the Y direction. In
most cases, you should increase the default values by a factor of 4 to 10 times
to improve the accuracy of the interpolation. For this example, try changing the
number of lines in the X and Y directions to 250 and 30 respectively (i.e.
increase the default values by a factor of 5). The SURFER program will create
a corresponding RATCHRO_TOPRESLOG.GRD file. Next click 'Map' on the
top menu bar and then 'Contour'. In the 'Contour' option, read in the
RATCHRO_TOPRESLOG.GRD file. Next the 'Contour Map' dialog box will
be shown. In this dialog box, click the 'Fill Contours' option. Next click the
'Load' button, and then read in the RATCHRO_TOPRESLOG.LVL file to set
the contour values and colours. If you wish to display the colour scale and
smooth the contours, click the 'Color Scale' and 'Smooth Contours' options.
Next click OK.
2). Next you need to mask out sections of the contour display. In the 'Map'
menu, click 'Load Base Map'. Choose the RATCHRO_TOPRESLOG.BLN as
the base map file. In the 'GS Blanking Import Options', just click OK. Do not
use the 'Areas to Curves' option. Next press F2, and then click the 'Overlap
Maps' option in the 'Map' menu. This will combine the contour map and the
base blanking map into a single map. Select the overlay by clicking near one of
the corners of the rectangle containing the contour map, and then select the
'Edit Overlays' command from the 'Map' menu. In the 'Edit Components' dialog
box, click the 'Base' and then click 'Move to Front' button. Next hold down the
CTRL key on the keyboard and click the overlay until the base map is
selected (as shown by the status indicator 'Map:Base' near the bottom left
corner of the screen). Next click the 'Draw' menu, and then choose the 'Fill
Attributes' option. Select the blank or white colour as the colour for the fill
108
attributes. Next click the 'Line Attributes', and also select the white colour so
that the overlay lines are not visible in the display.
3). Click the 'Post' command in the 'Map' menu, and then read in the
RATCHRO_TOPRESLOG_POST.DAT file (which contains the location of
the electrodes) in the 'Open Data' dialog box. After reading in this file, the 'Post
Map' dialog box will be shown. In this dialog box, select the symbol shape and
size and other options you want to use, and then click OK. After that, press F2,
and then click the 'Overlay Maps' command in the 'Map' menu. Next click the
figure and then the 'Edit Overlays' command in the 'Map' menu. Click 'Post'
and the 'Move to Front' , and the electrodes will be drawn on top of the model
section.
After drawing the section in the SURFER window, you can use other options
within SURFER to improve the model section, such as changing the font,
labels, titles etc., before printing the results or exporting it to another format.
SURFER supports a large variety of formats, including bit-mapped graphics
formats such as PCX, BMP, GIF etc.; and well as vector-based formats such as
the AUTOCAD DXF format.
For model sections without topography, step (3) where the post data map is
read is probably not necessary. However, you might need to adjust the tick
marks on the vertical scale on the left side of the contour plot. The depths are
given as negative values so that SURFER will plot the figure in the correct
orientation with the ground surface on top. As an example, draw the model
section for the Sting Cave example using the CAVE_MODRESLOG.DAT,
CAVE_MODRESLOG.LVL and CAVE_MODRESLOG.BLN files provided.
After you have drawn the model section, it is likely that you will only see the
0.0 mark on the left vertical axis for the depth scale. Click the left axis with the
right mouse button and the 'Left Axis' dialog box will be shown. Next click the
'Scaling' button in the dialog box. In the 'Axis Scaling' dialog box, change the
'Major Interval' value to 10 and the 'First Major Tick' to -40. Click OK to save
the values, and the left axis model section should then show ticks at depth
intervals of 10.
There will be slight differences in the contour sections drawn by SURFER and
RES2DINV due to the differences in the interpolation methods used. SURFER
does not use the original data points, but an interpolated rectangular grid of
points to draw the contours. The differences will probably be more obvious in
areas with very rapid changes in the resistivity. One way to reduce the
differences is to increase the number of grid lines used by SURFER for the
interpolation grid.
109
This allows you to choose model cells with widths of half the unit electrode
spacing. In almost all cases, this gives the optimum results. After selecting this
option, you must read in the data file. The program will then automatically
reduce the unit electrode spacing it uses by half of that given in the data file.
The second method is to modify the data file directly using a text editor. The
unit electrode spacing is given in the second line of the apparent resistivity data
file. For example, the first few lines of the PIPESCHL.DAT file are reproduced
below.
Underground pipe survey
1.00
7
173
1
0
110
1.50
1.00
641.1633
In the second data line, the unit electrode spacing is given as 1.0 metre that is
the actual spacing used in this survey. When the RES2DINV reads in this data
file, it will set the width of the model cells to 1.0 metre. The file
PIPESCHL_HALF.DAT has the same data except that the unit electrode
spacing is now defined as 0.5 metre. The upper part of this file is shown below.
Underground pipe survey - half actual electrode spacing
0.5
7
173
1
0
1.50 1.00 1 641.1633
When the RES2DINV program reads this file, it will set the model cells to a
0.5 metre width. Figure 34 shows the inversion models for this data set using
cells with widths of 1.0 and 0.5 metre. The model with the 0.5 metre cell width
is able to more accurately model the high resistivity anomalies near the surface
between the 3 and 12 metres marks above the low resistivity pipe, and thus has
a slightly lower apparent resistivity RMS error. The Wenner-Schlumberger
array was used for this survey.
In most cases with large resistivity variations near the surface, using a model
with a cell width of half the actual unit electrode spacing is sufficient. In some
cases, using a narrower cell width of one-third or one-quarter the unit might be
justified, particularly if the survey was carried out using a pole-dipole or
dipole-dipole array with very high n factors. If the cell width is one-quarter
the true unit electrode spacing, or less, oscillations in the model resistivity
values in the first few layers can occur. Thus the use of a cell width of less than
one-quarter the true unit electrode spacing is not advisable.
It is recommended that you refer to section 4.7j of the free notes Tutorial : 2D and 3-D electrical imaging surveys that can be downloaded from the
www.geoelectrical.com web site. This section has a discussion on the effect of
using high n factors with the pole-dipole array on the sensitivity of the array
to near-surface anomalies.
111
Figure 34. (a) The apparent resistivity pseudosection for the PIPESCHL.DAT
data set. The inversion models using (b) cells with a width of 1.0 metre that is
the same as the actual unit electrode, and (c) using narrower cells with a width
of 0.5 metre. The pipe is marked by the low resistivity anomaly below the 12
metres mark. Note the near-surface high resistivity anomalies between the 3
and 12 metres marks. The Wenner-Schlumberger array was used for this
survey.
112
113
A script file is used to combine the 2-D files. The file COLLATE_2D_3D.TXT
is an example script file. The contents of this file together with a description of
the format used is given below.
COLLATE_2D_3D.TXT file
| Comments
The format used allows for the possibility that the survey had lines in 2
perpendicular directions.
A 2-D survey line has only one horizontal direction, and the coordinate of an
electrode along the survey line is given as the distance along the line, starting
from the first electrode. To determine the coordinate of the electrode in the XY plane for a 3-D survey, we need to determine the coordinate of the first
electrode in the 2-D survey line within the X-Y survey grid. This gives a
reference point for which the coordinates of the other electrodes along the same
survey line can be calculated.
114
| Comments
115
c:\data\file_123.DAT
End of file
In some resistivity meter multi-electrode systems, each new record starts with a
zero location for the first data electrodes. In order to combine different data
files, the x-locations of the data points in some of the files will have to shifted
so that all of them have a common origin. In the above script file format, this is
done by entering the coordinate of the first electrode for the survey line. In
most cases, the direction of the lines are the same, for example the x-locations
increases from the left to the right. However, an option is provided where the
survey lines were measured in different directions.
116
On clicking this menu option, the model section will first be drawn, and then
the following dialog box is shown. On clicking the Edge detection dialog is
shown.
There are 3 main parameters that the user need to select. The first is to set
upper and lower limits for the location of the boundary. By default, the
program will set them from 0 m. (on the ground surface) until the maximum
depth extent of the inversion model. In most cases, the upper limit is
commonly changed, particularly where there are large resistivity anomalies
117
near the surface (for example boulders). In this particular example, the
minimum depth is set at 15 m. for the bedrock interface.
The second important parameter is a minimum value for the bedrock. In this
example, a value of 150 ohm.m was chosen that probably corresponds to
partially weathered diorite. The third parameter is the maximum change in the
bedrock depth between adjacent electrodes. This is to prevent spikes in the
bedrock profile.
In most cases, the default values for the other parameters should work well. By
default, it is assumed that the bedrock has a higher resistivity than the
overburden. However, a provision is made for cases where the bedrock or a
subsurface layer of interest has a lower resistivity.
For most situations, the robust model inversion option should be used
(Appendix K). This normally produces a sharper bedrock boundary in the
118
inversion model. Also, a model where cells have widths of half the actual unit
electrode spacing (Appendix O) is recommended. For example the Stud Farm
survey was conducted with a unit electrode spacing of 25 m., but inversion
model below uses smaller cell widths.
Figure 35. Apparent resistivity pseudosection from the Stud Farm survey
together with the inversion model. The interpreted bedrock profile is also
shown. Note that the bedrock on the right end of the line is below the
maximum depth of investigation of the survey line.
119
Comments
11.868
11.867
11.863
11.860
11.856
11.851
| Title
| Unit electrode spacing
| Array type, Wenner-Schlumberger in this
| example
| Number of datum points
| Mid-point of x-location of array is given
| No I.P. data
| Header to indicate time-lapse data
| Header
| Number of time series
| Header
| Unit used in time measurement
| Header
| Time difference for second time data set
| Header
| Time difference for third time data set
| The format for each datum point is as follows :
| x-location, "a" electrode spacing, "n" factor,
| apparent resistivity for first data set, apparent
| resistivity for second data set,
| apparent resistivity for third data set.
|
The data format is largely similar to the normal data set with only one set of
readings. For a time-lapse data file, the main difference is the extra section just
120
before the data block with the apparent resistivity values. Here the header
"Time sequence data" is used to indicate the presence of the extra data sets
corresponding to the later time measurements. The following part of this extra
section contains information on the number of time series measurements (3 in
this example). The maximum number of time series data sets allowed is 12 if
the computer has at least 256 MB RAM, and 6 if the memory available is less.
For each data point, the format for the initial part is identical to that used for
the normal data sets. The only addition is that after the apparent resistivity
value for the first data set, the corresponding apparent resistivity values for the
later time data sets are given.
This program allows the use of joint inversion techniques using different types
of cross model constrains. When you select the "Select time-lapse inversion
method" under the "Change settings" menu, the follow dialog box is shown.
In the first set of options in the dialog box, several possible constrains which
guides the inversion process for multi-time data sets provided. Frequently, the
data from time-lapse surveys conducted at different times are inverted
independently. This method corresponds to the 'No constrains" option in the
above dialog box. The changes in the subsurface resistivity values are then
determined by comparing the model resistivity values obtained from the
inversions of an initial data set and the later time data sets. In many cases, such
121
122
all the other data sets. In case where there is a large change in the resistivity of
the models from the first to the last data set, an option is provided where the
model for the preceding data set is used as the reference model. In this case, the
model for the first data set is used as the reference model for the second data
set, while the model for the second data set is used as the reference model for
the third data set, and similarly for the other data sets.
The last option, the time-constrain weight, gives the relative importance given
to keeping the later time models as similar as possible to the reference model.
If a large weight is used, for example 10.0, the models for the later time data
sets will be kept very similar to the reference model. This effectively
minimises changes across the time models and reduces the possibility of noise
in the data sets causing spurious changes between the models. However, this is
at the expense of increasing the data misfit, i.e. the RMS difference between
the calculated and measured data. By default, a value of 3.0 is used for the
time-constrain weight. A value of 1.0 gives equal importance to minimising the
time changes in the model and minimising the RMS data error.
After carrying out the inversion of the time-lapse data set, please switch to the
Display window to read in the results in the inversion file. Several options
are provided to display the results from the time-lapse models. The options
designed specifically for time-lapse inversion models are given near the bottom
of the Display sections list in the Display window, as shown below.
123
The "Display percentage change in resistivity" option will display the change
in the model resistivity obtained from the inversion of a later time data set
compared with the reference model from the inversion of the first data set. The
"Display resistivity ratio" option will display the ratio of resistivities of the
later time model compared with the reference model.
After displaying the sections with the percentage change in the model
resistivity values, you can change the time-lapse data set selected by using the
'Home' and 'End' keys. By default the results for the last time-lapse data set will
be shown. You can show the results of an earlier data set by pressing the
'Home' key.
Just below the menu options to display the time-sections, there is a " Change
factor in Archie's Law" sub-option. Archie's Law which gives the relationship
between the resistivity of a porous rock and the fluid saturation factor is
applicable for certain types of rocks and sediments, particularly those that have
a low clay content. In the case, the electrical conduction is assumed to be
through the fluids filling the pores of the rock. Archie's Law is given by
= a w m
where is the rock resistivity, w is fluid resistivity, is the fraction of the
rock filled with the fluid, while a and m are two empirical parameters (Keller
and Frischknecht 1966). For most rocks, a is about 1 while m is about 2. Under
certain special conditions, the above equation can be used to determine the
change in the fluid saturation or fluid resistivity with time.
If initially the subsurface material is saturated with water, and the change in the
resistivity is caused by withdrawal of water (i.e. a reduction in the fraction per
unit volume of the rock which is filled with water), the desaturation factor
(Keller and Frischknecht 1966) can be calculated from the change in the
subsurface resistivity. To calculate the desaturation factor, the value of the m
parameter in Archie's Law is needed. By default it is set to 2.0 but this value
can be changed by the user.
On the other extreme, consider a case where the fluid saturation factor does not
change but the resistivity of the fluid changes (for example in tracer
experiments with a conductive salt below the water table). The ratio of the
resistivity of the fluid at the later time to the initial resistivity can be calculated
directly from the model resistivities.
It must be emphasised that the above two situations are ideal cases. The results
are only valid if Archie's Law holds for the subsurface medium. In many cases,
124
the relationship between the medium resistivity and water content is much
more complicated (Olivar et al. 1990).
As an example of a field experiment of time-lapse measurements, Figures 36
and 34 shows the results from the tests on the flow of water through the
unsaturated zone conducted in Birmingham (Barker and Moore, 1998). Forty
thousand litres of water was poured on the ground surface near the 24 metres
mark along the survey line (Figure 36) over a period of 10 hours. The initial
data set collected before the water irrigation began together with the
corresponding inversion model is shown in Figures 36a and 36b. The
subsurface consists of sand and gravel is highly inhomogeneous. As a
comparison, Figure 36c shows the inversion model for the data collected after
the irrigation of the ground surface was completed. The distribution of the
water is not very clear from a direct comparison of the inversion models alone.
Figure 36. (a) The apparent resistivity and (b) inversion model sections from
the survey conducted at the beginning of the Birmingham infiltration study.
This shows the results from the initial data set which forms the base model in
the joint inversion with the later time data sets. As a comparison, the model
obtained from the inversion of the data set collected after 10 hours of irrigation
is shown in (c).
125
The water distribution is more easily determined from a plot of the percentage
change in the subsurface resistivity in the inversion models for the data sets
taken at different times (Figure 37) when compared with the initial data set
model. The data set collected at 5 hours after the pumping began shows a
reduction in the resistivity (of up to over 50 percent) near the ground surface in
the vicinity of the24 metres mark. The near-surface low resistivity zone reaches
its maximum extent and maximum amplitude after about 10 hours when the
pumping was stopped (Figure 37b). Twelve hours after the pumping was
stopped, the low resistivity plume has spread downwards and slightly outwards
due to infiltration of the water through the unsaturated zone. There is a
decrease in the maximum percentage reduction in the resistivity values near the
surface due to migration of the water from the near surface zone. This effect of
the spreading of the plume becomes increasingly more pronounced after 24
hours, 36 hours and 52 hours (Figures 37d, 37d, 37f) due to further migration
of the water. Note that the bottom boundary of the zone with approximately 20
percent reduction in the resistivity values tends to flatten out at a depth of about
3 metres (Figure 37e) where the plume from the surface meets the water table.
Missing data :- If a measurement was missing from a time series, enter 0.0 as
the value of the apparent resistivity for that particular time series. The program
will assume that a zero value is an indication of a missing data point.
126
Figure 37. Sections showing the change in the subsurface resistivity values
with time obtained from the inversion of the data sets collected during the
infiltration and recovery phases of the study.
127
Comments
Block Model
1.00
7
230
1
0
Error estimate for data present
| Title
| Unit electrode spacing
| Wenner-Schlumberger array
| Number of data points
| Type of x-location (center)
| No IP
| Header to indicate error values
| present
| Header for type of error
| 0 to indicate it is same unit as data
| value
| x-loc., a value, n value, apparent
| resistivity, data point error value
|
Note there are two new additions in the data format. Firstly, just before the
section of the file with the measured apparent resistivity data points, there are 3
extra lines. The first line Error estimate for data present is a header to indicate
that the data file contains the data error estimates. The second new line is a
header to explain the use of the next line. The third line contains a flag to
indicate to the program the units used in the error estimate. At present, use a
value of 0 to indicate that the error value has the same units as the data value.
For example, if the measurements are given as ohm.m, then the error values
must also be in ohm.m The measurements in most instruments are given as
resistance values (i.e. ohm), or voltage plus current values which can be
converted to resistance values. To calculate the apparent resistivity value, the
resistance value is multiplied by a geometric factor. The error value recorded
by the instrument is probably in the form of a resistance (ohm) value. Thus the
error estimate recorded by the instrument must also be multiplied by the same
128
geometric factor before it is entered into the DAT file format used by this
program.
The use of the flag for the unit used by the error value makes it possible for
future versions of the program to allow the use of other units for the error
value, for example the data in ohm.m while the error in ohm. Another
possibility is the error given as a percentage value.
The least-squares equation in (2) is modified to the following equation
(J
WdT Wd J + F d= J T WdT Wd g Fq k
129
58.63305
56.77204
54.79331
Comments
| Title
| Unit electrode spacing
| Wenner array
| Number of data points
| Type of x-location (center)
| No IP
| x-loc., a value, apparent resistivity
| Second data point
| Third data point
| Other data points
.
.
48
32
18.1012
50
32
17.94035
0
0
0
Sharp layers present
Number of boundaries
2
Boundary 1 parameters
Boundary type
Layer
Group weight
1.0
Number of points on boundary
16
x and z coordinates of pts
0.0 2.3
18.0 2.3
.
.
88.0 3.2
|
| Last data point
| No topography
| No fixed regions
| No water layer
| Header to indicate sharp boundaries present
| Information header
| Number of boundaries, two in this case
| Header for first boundary
| Header for type of boundary
| Layer type
| Header for weight, for future use
| Enter 1.0 here, not used at present
| Header
| 16 points for this boundary
| Header
| x-location and depth of first point
| x-location and depth of second point
| x-location and depth of other points
| along the boundary
| x-location and depth of second last point
130
92.0 3.2
Boundary 2 parameters
Boundary type
Layer
Group Weight
1.0
Number of points on boundary
3
x and z coordinates of points
0.0 6.7
45 6.7
92 6.7
0
0
0
In the above example, there are two boundaries. If there is more boundaries,
the section with Boundary 3 parameters until the x-location and depth of the
last point along the second boundary is repeated. The file
MODEL_BOUNDARY_GENERAL.DAT gives an example of a data file with
the general array format with only one boundary.
Figure 38 shows the inversion of the CLIFLAYER4.DAT data set using
different inversion options. The first model using the smooth inversion method
shows a gradational transition between the sand and underlying lower
resistivity clay layer (Figure 38b). The depth to the boundary is not well
determined. The use of the blocky or robust inversion method (Loke et al.
2003) gives a much sharper boundary (Figure 38c). The addition of the
boundary from the seismic refraction survey helps to further sharpen the
boundary (Figure 38d).
The greatest limitation of this option at present is that the depths to the layers
are fixed throughout the inversion. An option to allow the depths to be
automatically changed will probably be added in a future update.
131
Figure 38. Models for the Clifton survey from the different inversion methods
are shown together. Note the boundary between the high resistivity sand layer
and the underlying low resistivity clay layer is much better resolved in the
blocky and sharp boundary inversion methods.
132
133
Comments
Gradient array
| Title
1.0
| Unit electrode spacing
11
| Array type (11 for general array)
15
| Sub-array type 15
Type of measurement (0=app. resistivity,1=resistance) | Header
0
| 0 here to indicate apparent resistivity values
1792
| Number of data points
1
| Indicator for type of x-location
0
| No IP values, 1 if I.P present
4 0.0,0.0 9.0,0.0 1.0,0.0 2.0,0.0 5.0588 | The format for each data point is
4 1.0,0.0 10.0,0.0 2.0,0.0 3.0,0.0 5.0724 | Number of electrodes used in
.
.
4 46.0,0.0 118.0,0.0 78.0,0.0 86.0,0.0 4.2571 | Last two data
4 48.0,0.0 120.0,0.0 80.0,0.0 88.0,0.0 4.2258 | points
0,0,0,0,0
| End with a few zeros
To select the type of plotting method to use, before reading the data file, click
'Change Settings' and then 'Data/Display Selection', and then 'Type of gradient
array plot' as shown in the following figure.
134
On selecting the Type of gradient array sub-option, the following dialog box
is shown.
The Use exact pseudodepth choice is the default option. However, the
program will automatically change to the approximate pseudodepth method if
it finds the exact pseudodepth method is not suitable for the data file. This
occurs for surveys with the traditional type of gradient arrays where only a few
C1-C2 positions are used.
The CROMER02.DAT file has the data from a survey using a multiple
gradient array was carried out by Aarhus University for the Danish Road and
Highway Association. A plot of this data set in the form of profiles is shown in
the following figure.
135
Figure 40. Two different configurations of the gradient array with the same
pseudodepth but with the potential electrodes at different ends of the array.
Gradient array configuration with (a) right parity and (b) left parity.
In the above example, the distance between the C1 and C2 electrodes are the
same. The offset of the P1-P2 dipole from the C1 electrode in (a) is the same as
the offset of the dipole from the C2 electrode in (b). However, the two
configurations are sensitive to different parts of the subsurface (Dahlin and
136
Zhou 2005). To provide a smooth plot for the profile, the data from the right
and left configurations are plotted in different profiles.
If the program finds that it is not practical to plot the profiles using the exact
pseudodepth, it will automatically switch to the approximate pseudodepth
method. For each C1-C2 spacing, the data is split up into more than 2 profiles
that are plotted using different colors.
Figure 41. Plot of CROMER02.DAT data in the form of profiles using the
approximate pseudodepth method.
137
The inversion model of the CROMER02.DAT data set that also shows the plot
of the data in apparent resistivity pseudosections is shown below.
Figure 42. The inversion result of the CROMER02.DAT data set with the
apparent resistivity and model sections.
138
Comments
|-------------------------------------------------------
Blocks with IP
2.00
10
1.00
530
1
1
Chargeability
Msec
0.10,1.00
2.0 2.0 1.0 100.7976
4.0 2.0 1.0 102.0548
6.0 2.0 1.0 104.9487
8.0 2.0 1.0 111.0159
| Title
| Unit electrode spacing
| Array type (10 for offset pole-dipole)
| Offset of current electrode from survey line
| Number of data points
| To indicate mid-point of array given as x-location
| 1 to indicate IP present
| Type of IP data
| IP unit
| Delay, integration time
| For each data point, we have
| x-location, a dipole spacing, n factor,
| apparent resistivity, apparent IP
|
-0.9118
-1.8678
-4.3391
-9.0335
139
..
..
53.0
2.0
5.5469
-10.0
109.3857
0,0,0,0,0
The data format is essentially the same as the normal pole-dipole array, except
the array number is 10 and the offset distance is given immediately after the
array number.
The file OFF_PDP_GEN.DAT is an example data file with data given in the
general array format. Below is the initial part of the example
GRADIENT.DAT file with comments about the format.
OFF_PDP_GEN.DAT file
Comments
----------------------------------- |------------------------------------------------------Blocks with IP
2.00
11
10
1.00
Type of measurement (0=app.
resistivity,1=resistance)
0
530
1
1
Chargeability
Msec
0.10,1.00
3 0.0,0.0
2.0,0.0
4.0,0.0
100.7976 -0.9118
3 2.0,0.0
4.0,0.0
6.0,0.0
102.0548 -1.8678
3 4.0,0.0
6.0,0.0
8.0,0.0
104.9487 -4.3391
3 6.0,0.0 8.0,0.0 10.0,0.0
111.0159 -9.0335
..
..
3 64.0,0.0 44.0,0.0
109.3857 5.5469
0,0,0,0,0
42.0,0.0
| Title
| Unit electrode spacing
| Array number 11 for general array
| Sub-array type (10 for offset pole-dipole)
| Offset of current electrode from survey line
| Header
| 0 here to indicate apparent resistivity values
| Number of data points
| To indicate mid-point of array given as x-location
| 1 to indicate IP present
| Type of IP data
| IP unit
| Delay, integration time
| For each data point, we have
| Number of electrodes used in measurement,
| x- and z-location of C1 electrode,
| x- and z-location of P1 electrode
| x- and z-location of P2 electrode,,
| apparent resistivity, apparent IP
| Other data points
|
| Last data point
| A few zeros to end the file
Note that the offset b must be the same for all measurements in a single
survey line.
140
4.500
5.000
5.000
10.132
9.601
9.601
0
Global Coordinates present
Number of coordinate points
3
Local Longitude Latitude
0.0 20.0 10.0
Comments
------------------------------------------------------Last
three
data points
Topography flag, 0=no topography
Header to indicate GPS information present
Header
Number of coordinate points
Header
First coordinate point given as
Local position along line, GPS Longitude, GPS
Latitude
Second coordinate point
Third coordinate point
Zeros to indicate other options,
such as fixed regions etc.
not present
An example for a data file with topography using the index based format is
given in the file RATCHRO_GLOBAL.DAT. The section of the file
containing the GPS information given after the topography section is shown
below.
141
RATHCRO_GLOBAL.DAT
file
----------------------------------92,-3.207
94,-3.27
96,-3.34
1
Global Coordinates present
Number of coordinate points
3
Local Longitude Latitude
-36.0 80100.0 200300.0
Comments
------------------------------------------------------Last
Three topography
data points
Indicates first topography point coincides with first
electrode
Header to indicate GPS information present
Header
Number of coordinate points
Header
First coordinate point given as
Local position along line, GPS Longitude, GPS
Latitude
Second coordinate point
Third coordinate point
Zeros to indicate other options,
such as fixed regions etc.
not present
Comments
--------------------------------------------------
142
Comments
--------------------------------------------------
4
1056.62,0.0
1083.62,0.0
1065.62,0.0 1074.62,0.0 95.383
Topography in separate list
2
38
26.12 999.09
..
..
1127.76 999.09
1
To make use of the GPS coordinates, you need to first run an inversion of the
data set. Next read the inversion file in the Display window, and then save the
model values in an XYZ file using the File Save data in XYZ format
option. The model values with the GPS coordinates will be listed in the last
section of the XYZ file.
143
144
DISCLAIMER
This software is provided "as is" without any express or implied warranties
including its suitability for a particular purpose. Neither the author nor the
subagent will assume responsibility for any damage or loss caused by the use
of this program. In the event of program bugs, every effort will be made to
correct the bugs and a replacement program will be provided for a nominal
charge to cover postage and handling. Faulty dongles or program disks will be
replaced free of charge within the first 6 months from the date of purchase to
registered users. Registered users are entitled to free updates and support
within the first year.
SUPPORT
Please contact your distributor if you have any questions concerning this
program. A frequent source of queries is when the results obtained are not what
you expect, or the program refuses to accept your data file. In such a case,
support will only be provided if a copy of the data file is sent together as an
attachment with your email, preferably compressed into a ZIP file. The most
common causes of problems are (a) the data in the DAT file is not given in the
correct RES2DINV format (b) excessive noise in the data set (particularly for
dipole-dipole surveys and/or IP data sets) (c) instrument malfunction or field
survey errors. It is only possible to trace the source of the problem if a copy of
the data file is provided.
Please note that support is only available for registered users of the full version
of the program. It is not possible to provide technical support for users of the
demo version of this software. For technical support, you can contact the
software provider by email at the following addresses. Please attach a copy of
your data file to your email.
[email protected]
[email protected]
The following information will be required before technical support is
provided.
1). Your dongle ID number. This ID number is displayed near the bottom of
the initial information box when the RES2DINV program starts up if the
dongle is attached to the computer.
2). The name of your company or institution.
3). Approximate date your company/institution purchased the software.
145
Whats New
Version 3.00 - Major upgrade to Windows 3.1 and 95. Maximum number of
electrodes increased to 500. Multi-tasking support for Windows 95. Support for
any Windows compatible graphics card and printer.
Version 3.01 - Improvements to finite-difference subroutine to calculate the
Jacobian matrix which is now about twice as fast as the earlier versions.
Version 3.10 - Support for underwater surveys. Direct incorporation of
topography into inversion model using a distorted finite-element grid.
Version 3.11 - The time taken by the finite-element subroutine to calculate the
Jacobian matrix is reduced. An option to use a finer mesh for the finitedifference or finite-element forward modelling method is added.
Version 3.12 - Non-integer values for the n factor for the dipole-dipole, poledipole and Wenner-Schlumberger arrays supported (please refer to Appendix
A). The maximum limits for the number of data levels and model layers
increased to 52 and 17 respectively.
Version 3.13 - The ratio of the largest electrode spacing to unit electrode
spacing for the Wenner and pole-pole array was increased from 32 to 64. The
maximum number of data levels is now 64. The maximum number of model
layers was also increased to 18.
Version 3.20 - Support for IP data added.
Version 3.21 - The maximum number of electrodes was increased to 650.
Improvements has been made to the disk-memory swapping subroutines so that
for a given amount of RAM the number of datum points the program can
handle is increased. For computer systems with more than one hard-disk drive,
the program will automatically select the drive with the most free disk space to
store the temporary disk swap files.
Version 3.22 - Slight improvements to the use of memory in the IP inversion
section. The size of the IP data set that can be handled for a given amount of
memory was increased. An option to optimise the damping factor
automatically during the inversion process was added. Support for the
reverse pole-dipole array added (see Appendix A). Support for a command
line batch mode included (see Appendix I). An option to plot the model section
in the form of rectangular blocks was also added.
146
147
electrode spacing has been reduced by half of the actual value so as to get a
model where the width of the blocks is half the usual size. This helps in cases
where there are very large lateral resistivity variations near the surface.
Version 3.44 - Support for IP surveys with non-conventional arrays. This
feature is useful in some cases where data from a series of overlapping
collinear 1D sounding survey lines can be combined into a single 2-D data set
to obtain a 2-D model.
Version 3.45 - Option to save results in SURFER format added. Also support
for surveys with some electrodes underwater and some electrodes above the
water surface level added.
Version 3.46 - Minor additions for data in general array format. Option to use a
model with half the unit electrode spacing for data in general array format is
added (see the file RATCMIX2.DAT for an example). It is now possible to
carry out the inversion of data in the general array format with the demo
version, but the results will only be displayed temporarily on the screen during
the inversion. The damped distorted grid finite-element method is set as the
default method for topographic modelling.
Version 3.47 An option to carry out the inversion of IP data sequentially was
added. Slight changes in the menu structure.
Version 3.48 Support for up to 4 boreholes in cross-borehole option.
Version 3.49 Incomplete Gauss-Newton inversion option added. Maximum
number of electrodes increased to 4000, and maximum number of data points
to 20000. Option to combine a number of 2-D data files in RES2DINV format
into a single 3-D data file in RES3DINV format added.
Version 3.50 Bedrock edge detection and time-lapse options added.
Version 3.51 Option to include data noise estimates included.
Version 3.52 Option for surveys with floating electrodes added. Support for
topography in cross-borehole surveys included.
Version 3.53 Sparse inversion option for very long survey lines (2000 to
16000 electrode positions) added. This method inverts the entire data set and
model at a single time to produce a continuous and seamless model. New
format for batch mode option script file which makes use of the files
containing the inversion parameters produced by the RES2DINV program.
148