Long-Distance Proximity Sensor: Ordering Information

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

Long-distance Proximity Sensor

E2EM

Safe Mounting with Greater Sensing


Distance and Easy Wiring with No
Polarity
Ensures a sensing distance approximately 1.5 to 2
times larger than that of any conventional OMRON
Sensor.
Offers greater design flexibility and ease for the
detection of large-sized or non-ferrous sensing
objects.
Problems such as the collision of workpieces are
eliminated.
The E2EM has no polarity, thus eliminating
problems associated with reversed wiring.
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing the
products. Please consult your OMRON representative if you have
any questions or comments.

Ordering Information
DC 2-wire/Pre-wired Models
Type
yp

Size

Model

Sensing
g distance
NO

Shielded

Unshielded

Note:

NC

M12

4 mm

E2EM-X4X1 (see note)

E2EM-X4X2

M18

8 mm

E2EM-X8X1 (see note)

E2EM-X8X2

M30

15 mm

E2EM-X15X1 (see note)

E2EM-X15X2

M18

16 mm

E2EM-X16MX1

E2EM-X16MX2

M30

30 mm

E2EM-X30MX1

E2EM-X30MX2

Connector relay models (cable length of 300 mm) are available.

DC 3-wire/Pre-wired Models
Type
yp

Size

Model

Sensing
g distance
NPN NO

Shielded

PNP NO

NPN NC

PNP NC

M8

2 mm

E2EM-X2C1

E2EM-X2B1

E2EM-X2C2

E2EM-X2B2

M12

4 mm

E2EM-X4C1

E2EM-X4B1

E2EM-X4C2

E2EM-X4B2

M18

8 mm

E2EM-X8C1

E2EM-X8B1

E2EM-X8C2

E2EM-X8B2

M30

15 mm

E2EM-X15C1

E2EM-X15B1

E2EM-X15C2

E2EM-X15B2

DC 3-wire/Connector Models
Type
Shielded

Note:

Size

Sensing distance

Output configuration
NPN NO

Model

M8

2 mm

E2EM-X2C1-M1

M12

4 mm

E2EM-X4C1-M1

M18

8 mm

E2EM-X8C1-M1

M30

15 mm

M8

2 mm

M12

4 mm

E2EM-X4B1-M1

M18

8 mm

E2EM-X8B1-M1

M30

15 mm

E2EM-X15B1-M1

E2EM-X15C1-M1
PNP NO

E2EM-X2B1-M1

Models with output configuration of NPN NC and PNP NC are also available.

E2EM

E2EM

Specifications
Ratings/Characteristics
E2EM-XjXj DC 2-wire Models
Item

E2EM-X4Xj

E2EM-X8Xj

E2EM-X16MXj

E2EM-X15Xj

E2EM-X30MXj

Size

M12

M18

Type

Shielded

Shielded

Unshielded

Shielded

Unshielded

Sensing distance

4 mm 10%

8 mm 10%

16 mm 10%

15 mm 10%

30 mm 10%

Setting distance (see note 1)

0 to 3.2 mm

0 to 6.4 mm

0 to 12.8 mm

0 to 12 mm

0 to 24 mm

Differential travel

15% max. of sensing distance

Sensing object

Ferrous metal (refer to Engineering Data for non-ferrous metal on page 4)

Standard object (mild steel)

12 x 12 x 1 mm

18 x 18 x 1 mm

45 x 45 x 1 mm

30 x 30 x 1 mm

70 x 70 x 1 mm

Response frequency (see note 2)

1 kHz

0.5 kHz

0.4 kHz

0.25 kHz

0.1 kHz

Power supply voltage (operating


voltage range)

12 to 24 VDC, ripple (p-p): 10% max., (10 to 30 VDC)

Leakage current

0.8 mA max.

Control output

M30

Switching
capacity

5 to 100 mA

Residual
voltage (see
note 3)

5 V max. (under load current of 100 mA with cable length of 2 m)

Indicator

X1 models:
X2 models:

Operation (with sensing object


approaching)

X1 models:
NO
X2 models:
NC
For details, refer to the timing charts on page 5.

Circuit protection

Surge absorber, load short-circuit protection

Ambient temperature

Operating: 25C to 70C (with no icing or condensation)


Storage: 40C to 85C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

15% max. of sensing distance at 23C in temperature range of 25C to 70C

Voltage influence

1% max. of sensing distance in rated voltage range 15%

Insulation resistance

50 M min. (at 500 VDC) between current carry parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions

Degree of protection

IEC60529 IP67

Connection method

Pre-wired models (standard length: 2 m)

Weight (packaged)

Approx. 60 g

Material

Case

Brass

Sensing
surface

PBT

Accessories
Note:

Operation indicator (red LED), operation set indicator (green LED)


Operation indicator (red LED)

Approx. 130 g

Approx. 150 g

Approx. 180 g

Approx. 210 g

Instruction manual

1. Use within a range where the green indicator is lit. (Excluding the X2 models.)
2. The response frequency of the DC switch section is an average value. Use standard sensing objects, provide a distance of twice the
standard sensing object distance between sensing objects, and provide a setting distance of half the sensing distance as measurement conditions.
3. Since the residual voltage is 5 V, confirm interface conditions with devices to be connected. Refer to page 11.

E2EM

E2EM
E2EM-XjBj/Cj DC 3-wire Models
Item

E2EM-X2Bj/Cj
(-M1)

E2EM-X4Bj/Cj
(-M1)

E2EM-X8Bj/Cj
(-M1)

E2EM-X15Bj/Cj
(-M1)

Size

M8

Type

Shielded

Sensing distance
Setting distance
Differential travel

10% max. of sensing distance

Sensing object

Ferrous metal (refer to Engineering Data for non-ferrous metal on page 4)

Standard object (mild steel)

8 x 8 x 1 mm

12 x 12 x 1 mm

18 x 18 x 1 mm

30 x 30 x 1 mm

Response frequency (see note 2)

1.5 kHz

0.5 kHz

0.3 kHz

0.1 kHz

Supply voltage (operating voltage


range) (see note 1)

12 to 24 VDC, ripple (p-p): 10% max., (10 to 40 VDC)

Leakage current

13 mA max.

Control output

M12

M18

M30

2 mm 10%

4 mm 10%

8 mm 10%

15 mm 10%

0 to 1.6 mm

0 to 3.2 mm

0 to 6.4 mm

0 to 12 mm

Switching capacity
(see note 1)

200 mA max.

Residual voltage

2 V max. (under load current of 200 mA with cable length of 2 m)

Indicator

Operation indicator (Yellow LED)

Operation (with sensing object


approaching)

B1, C1 models:
NO
B2, C2 models:
NC
For details, refer to the timing charts on page 5.

Circuit protection

Reverse connection protection, surge absorber, load short-circuit protection

Ambient temperature (see note 2)

Operating/Storage: 40C to 85C (with no icing or condensation)

Ambient humidity

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

15% max. of sensing distance at 23C within temperature range of


40C to 85C
10% max. of sensing distance at 23C within temperature range of
25C to 70C

Voltage influence

1% max. of sensing distance in rated voltage range 15%

Insulation resistance

50 M min. (at 500 VDC) between current carry parts and case

Dielectric strength

1,000 VAC at 50/60 Hz for 1 min between current carry parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z


directions

Shock resistance

Destruction:
500 m/s2 for 10 times
each in X, Y, and Z
directions

Degree of protection

IEC60529 IP67

Connection method

Pre-wired models (standard length: 2 m)


Connector models (-M1 models)

Weight
g
(
(packaged)
k
d)

Pre-wired

Approx. 55 g

Approx. 65 g

Approx. 140 g

Approx. 190 g

Connector

Approx. 10 g

Approx. 20 g

Approx. 40 g

Approx. 90 g

Material

Case

Stainless steel
(SUS303)

Brass

Sensing surface

PBT

Accessories
Note:

Operating:
25C to 70C
Storage:
40C to 85C
(with no icing or
condensation)
15% max. of
sensing distance
at 23C within
temperature range
of 25C to 70C

Destruction: 1,000 m/s2 for 10 times each in X, Y, and Z directions

Instruction manual

1. When using the M8 models within the temperature range from 70C to 85C, the voltage range must be from 10 to 30 VDC and
control output (switching capacity) must be 100 mA max.
2. The response frequency of the DC switch section is an average value. Use standard sensing objects, provide a distance of twice the
standard sensing object distance between sensing objects, and provide a setting distance of half the sensing distance as measurement conditions.

E2EM

E2EM

Engineering Data
Operating Range (Typical)

E2EM-X30MX

E2EM-X16MX

E2EM-XBj/Cj
E2EM-X15X

E2EM-X8X
E2EM-X4X

Sensing distance X (mm)

E2EM-XjXj
Sensing distance X (mm)

Shielded Models

E2EM-XjMXj
Sensing distance X (mm)

Unshielded Models

E2EM-X15B/C

E2EM-X8B/C

E2EM-X4B/C
E2EM-X2B/C

Sensing distance Y (mm)

Sensing distance Y (mm)

Sensing distance Y (mm)

Influence of Sensing Object Size and Materials


d

t = 1 mm

Mild steel
Stainless
steel
(SUS304)

E2EM-X8jj(-M1)

t = 1 mm
Mild steel

Stainless steel
(SUS304)

Sensing distance X (mm)

E2EM-X4jj(-M1)
Sensing distance X (mm)

Sensing distance X (mm)

E2EM-X2jj(-M1)

t = 1 mm

Mild steel
Stainless
steel
(SUS304)

Brass
Brass
Copper

Brass

Copper

Aluminum
Copper

Side length of sensing object d (mm)

Side length of sensing object d (mm)

t = 1 mm

Mild steel

Stainless steel
(SUS304)

E2EM-X30MXj

t = 1 mm
Mild steel
Stainless steel
(SUS304)

Sensing distance X (mm)

Side length of sensing object d (mm)

E2EM-X16MXj
Sensing distance X (mm)

Sensing distance X (mm)

E2EM-X15jj(-M1)

t = 1 mm

Mild steel

Stainless steel
(SUS304)
Brass

Brass
Brass
Aluminum
Copper

Side length of sensing object d (mm)

Copper
Aluminum

Side length of sensing object d (mm)

Copper
Aluminum

Side length of sensing object d (mm)

E2EM

E2EM
Residual Voltage Characteristics
Output residual voltage (V)

E2EM-XjXj

Load current (mA)

Operation
Output Circuits
E2EM-XjXj DC 2-wire Models

E2EM-X4X1
E2EM-X8X1
E2EM-X15X1
E2EM-X16MX1
E2EM-X30MX1

Timing chart

Non-sensing
zone
Sensing
object

Output circuit

Setting
position
Unstable
Stable sensing
sensing zone zone
Proximity
Sensor

Rated sensing

NO

Model

Brown
Load

distance

Operation

ON
OFF

Set indicator
(green)

ON
OFF

Operation
indicator
(red)
Control
output

ON
OFF
Non-sensing zone

Sensing zone

Proximity
Sensor

Sensing
object

distance

E2EM-X4X2
E2EM-X8X2
E2EM-X15X2
E2EM-X16MX2
E2EM-X30MX2

Rated sensing

NC

ON
OFF
ON
OFF

(0 V)
Main
circuit
Blue
0V

Note:

1. The load can be connected to either +V or 0 V line.


2. Since there is no polarity, there is
no need to pay attention to the
brown or blue polarity.

Operation
indicator
(red)
Control
output

E2EM

E2EM
E2EM-XjBj/Cj(-M1) DC 3-wire Models
Operation

NO

Output
specifications
NPN open
collector
output

NC

NO

Model

E2EM-X2C1 (-M1)
E2EM-X4C1 (-M1)
E2EM-X8C1 (-M1)
E2EM-X15C1 (-M1)

E2EM-X2C2
E2EM-X4C2
E2EM-X8C2
E2EM-X15C2

PNP open
collector
output

NC

E2EM-X2B1 (-M1)
E2EM-X4B1 (-M1)
E2EM-X8B1 (-M1)
E2EM-X15B1 (-M1)

E2EM-X2B2
E2EM-X4B2
E2EM-X8B2
E2EM-X15B2

Timing chart

Sensing object

Yes
No

Operation indicator
(yellow)

ON
OFF

Control output

ON
OFF

Sensing object

Yes
No

Operation indicator
(yellow)

ON
OFF

Control output

ON
OFF

Sensing object

Yes
No

Operation indicator
(yellow)

ON
OFF

Control output

ON
OFF

Sensing object

Yes
No

Operation indicator
(yellow)

ON
OFF

Control output

ON
OFF

Output circuit

Brown

Load
Black

Main
circuit

or

Blue
0V

Note:

Pin 4 is NO and pin 2 is NC.

Brown
+V

Black

Main
circuit

or 2
Load

100

Blue
3

Note:

0V

Pin 4 is NO and pin 2 is NC.

E2EM-XjBj/Cj-M1 DC 3-wire Models


Connector

Output configuration

M12

NO

Applicable
models

Pin arrangement

E2EM-XjC1-M1
Load

Note:

Terminal 2 is not used.

Load

Note:

Terminal 2 is not used.

Note:

Terminal 4 is not used.

Note:

Terminal 4 is not used.

E2EM-XjB1-M1

NC

E2EM-XjC2-M1

Load

E2EM-XjB2-M1

Load

E2EM

E2EM

Dimensions
Note:

All units are in millimeters unless otherwise indicated.

Pre-wired Models (Shielded)


Mounting Hole
Dimensions

Outer
diameter
F (mm)

E2EM-X2Bj/Cj

M8
8.5 dia.
+0.5/0

M12
12.5 dia.
+0.5/0

M18
18.5 dia.
+0.5/0

M30
30.5 dia.
+0.5/0

E2EM-X4jj

15 dia.

21 dia.

Indicator*2
Two, tightening nuts
Toothed washer

*1
Indicator*2
Two, tightening nuts
Toothed washer

*1: Vinyl-insulated round cable (2 cores/3 cores), 4 dia. (60/0.08 dia.)


Standard length: 2 m
Cable length (in single metal conduit): 200 m max.

*1

*1: Vinyl-insulated round cable (2 cores/3 cores), 4 dia.


Conductor cross-section: 0.3 mm2/insulator diameter: 1.3 mm
Standard length: 2 m

*2: Operation indicator: yellow

*2: X1 models: Operation indicator: red, set indicator: green


X2 models: Operation indicator: red
B/C models: Operation indicator: yellow

E2EM-X8jj

E2EM-X15jj

29 dia.

42 dia.

Indicator*2

*1

Two, tightening nuts


Toothed washer
*1: Vinyl-insulated round cable (2 cores/3 cores), 6 dia.
Conductor cross-section: 0.5 mm2/insulator diameter: 1.9 mm
Standard length: 2 m
*2: X1 models: Operation indicator: red, set indicator: green
X2 models: Operation indicator: red
B/C models: Operation indicator: yellow

Indicator*2

*1

Two, tightening nuts


Toothed washer
*1: Vinyl-insulated round cable (2 cores/3 cores), 6 dia.
Conductor cross-section: 0.5 mm2/insulator diameter: 1.9 mm
Standard length: 2 m
*2: X1 models: Operation indicator: red, set indicator: green
X2 models: Operation indicator: red
B/C models: Operation indicator: yellow

E2EM

E2EM
Pre-wired Models (Unshielded)

E2EM-X16MXj
29 dia.

14.8 dia.
Indicator*2

*1: Vinyl-insulated round cable (2 cores), 6 dia.


Conductor cross-section: 0.5 mm2/insulator diameter: 1.9 mm
Standard length: 2 m

*1

Two, tightening nuts


Toothed washer

*2: X1 models: Operation indicator: red, set indicator: green


X2 models: Operation indicator: red

E2EM-X30MXj
42 dia.

26.8 dia.
Indicator*2

*1: Vinyl-insulated round cable (2 cores), 6 dia.


Conductor cross-section: 0.5 mm2/insulator diameter: 1.9 mm
Standard length: 2 m

*1

*2: X1 models: Operation indicator: red, set indicator: green


X2 models: Operation indicator: red

Two, tightening nuts


Toothed washer

Connector Models (Shielded)


Mounting Hole
Dimensions

Outer
diameter
F (mm)

E2EM-X2Bj/Cj-M1

M8
8.5 dia.
+0.5/0

M12
12.5 dia.
+0.5/0

M18
18.5 dia.
+0.5/0

M30
30.5 dia.
+0.5/0

E2EM-X4Bj/Cj-M1
21 dia.

15 dia.

Indicator*
Two, tightening nuts
Toothed washer

Indicator*
Two, tightening nuts
Toothed washer *Operation indicator: yellow

*Operation indicator: yellow

E2EM-X8Bj/Cj-M1

E2EM-X15Bj/Cj-M1

29 dia.

42 dia.

Indicator*
Two, tightening nuts
Toothed washer
*Operation indicator: yellow

Indicator*
Two, tightening nuts
Toothed washer
*Operation indicator: yellow

E2EM

E2EM
When Proximity Sensor is Connected to Sensor I/O Connector
Shielded
(Straight)

Dimensions when connected to XS2F (unit: mm)


(L-shaped)
Sensor diameter

L1

M8

L2

Approx. 75

Approx. 62

DC

Approx. 80

Approx. 67

AC

Approx. 85

Approx. 72

M18

Approx. 85

Approx. 72

M30

Approx. 90

Approx. 77

M12

Accessories (Order Separately)


Mounting Brackets
Four kinds of resin mounting brackets are available. Choose an appropriate one depending on external dimensions

Dimensions (mm)

Model
A

Note:

Hexagonal
bolts

Applicable
Sensor
outer
diameter

Y92E-B8

180.2

10 max.

18

8 dia.

28 max.

M4 x 20

M8

Y92E-B12

240.2

12.5 max.

20

12 dia.

37 max.

M4 x 25

M12

Y92E-B18

320.2

17 max.

30

18 dia.

47 max.

M5 x 32

M18

Y92E-B30

450.2

17 max.

50

30 dia.

60 max.

10

M5 x 50

M30

When using the Mounting Brackets for unshielded models, pay attention to the influence of surrounding metals. (For dimensions of
Sensors, refer to the dimensions shown for each model.)

Installation
Connection with Sensor I/O Connectors
Proximity Sensors

DC
3-wire

Operation
NO

Sensor I/O Connectors

Connection

Model
E2EM-XjC1-M1

1: Straight
2: L-shaped

XS2F-D42j-jC0-A

E2EM

XS2F
Brown (+V)

Main circuit

Type

Blue (0 V)
Black
(Output)

D: 2-m cable
G: 5-m cable

NC

E2EM-XjC2-M1

XS2F D42j j80 A


XS2F-D42j-j80-A
D: 2-m cable
G: 5-m cable

Note:

E2EM
Main circuit

1: Straight
2: L-shaped

XS2F
Brown (+V)
White (Empty)
Blue (0 V)
Black
(Output)

Main circuit

E2EM

XS2F
Brown (+V)
White (Output)
Blue (0 V)
Black
(Empty)

For details, refer to the Sensor I/O Connectors Catalog (G010).

E2EM

E2EM

Precautions
! WARNING
This product is not designed or rated for ensuring
safety of persons.
Do not use it for such purposes.

Precautions for Safe Use


Power Supply

Connection with No Load

Do not impose an excessive voltage on the E2EM, otherwise it may


be damaged. Do not impose AC current (100 VAC) on any E2EM
DC model, otherwise it may be damaged.

Be sure to insert loads when wiring. Make sure to connect a proper


load to the E2EM in operation, otherwise it may damage internal elements.

Load Short-circuit

Do not expose the product to flammable or explosive gases.


Do not disassemble, repair, or modify the product.

Do not short-circuit the load, or the E2EM may be damaged.


The E2EMs short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range.

Wiring
Be sure to wire the E2EM and load correctly, otherwise it may be
damaged.

Precautions for Correct Use


Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load.
Effects of Surrounding Metal
When mounting the E2EM within a metal panel, ensure that the
clearances given in the following table are maintained.

Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
AND/OR Connection
When using the product in an AND/OR circuit, the product may not
function properly due to incorrect pulses or leakage currents.
Therefore, confirm that no problems will occur before actually using
the product in such a circuit.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.

d dia.

(Unit: mm)
Type
E2EMXjXj
DC 2-wire

Shielded

Unshielded

E2EMXjBj/Cj
DC 3-wire

10

Shielded

Item

M12

M18

M30

2.4

3.6

18

27

45

2.4

3.6

12

24

45

18

27

45

---

25

45

70

120

25

45

48

90

70

120

M8
---

---

2.4

3.6

18

27

45

2.4

3.6

4.5

12

24

45

12

18

27

45

(Unit: mm)
Type
E2EMXjXj
DC 2-wire

Shielded
Unshielded

Item

M12

M18

M30

30

60

110

20

35

90

---

200

350

120

300

M8
---

B
E2EMXjB/C
DC 3-wire

Shielded

20

30

60

110

15

20

35

90

E2EM

E2EM
Designing

Mounting

Confirmation of Connection between DC 2-wire Proximity


Sensor and Programmable Controller
Connection conditions are determined from the relationship between the input ON voltage and OFF voltage of the PC and the output residual voltage and leakage current of the Proximity Sensor.

The Proximity Sensor must not be subjected to excessive shock


with a hammer when it is installed, otherwise the Proximity Sensor
may be damaged or lose its water-resistivity.
Do not tighten the nut with excessive force. A washer must be used
with the nut.

Connection Conditions
1. Relationship between the ON voltage of the PC and the
residual voltage of the Proximity Sensor must be as follows:
VonxVcc VR
Von: ON voltage of the PC
Vcc: Supply voltage
VR: Output residual voltage the Proximity Sensor
2. Relationship between the OFF voltage of the PC and the
leakage current of the Proximity Sensor must be as follows:
VoffyIleak x Rin
Voff: OFF voltage of the PC
Ileak: Leakage current of the Proximity Sensor
Rin: Input impedance of the PC
Connection is possible under the following conditions.
Example values on the PC side
ON voltage: 10.2 V min.
OFF voltage: 3 V max.
Input impedance: 3.5 k
Example values on the Proximity Sensor side
Output residual voltage: 5 V max.
Leakage current: 0.8 mA max.
If these values are put in the above formula, Von and Voff will be as
follows:
Von: 10.2 Vt24 V5 V (=19 V)
Voff: 3 Vu0.8 mA x 3.5 k (=2.8 V)

Wiring
High-tension Lines
Wiring through Metal Conduit:
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning.
Connections
DC 2-wire Models
Connection to relay load
Brown

Shielded Model

Unshielded Model

Part B Part A

Note:

The table below shows the tightening torques for part A and
part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for
part B applies. If this nut is in part A, the tightening torque for
part A applies instead.
Type

Part A
Length

M8

Part B Part A

Shielded

9 mm

M12

30 N S m

M18

70 N S m

M30

180 N S m

Part B
Torque

9NSm

Torque
12 N S m

Maintenance and Inspection


Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
1. Check for mounting position, dislocation, looseness, or
distortion of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts,
and line breakage.
3. Check for attachment or accumulation of metal powder or
dust.
4. Check for abnormal temperature conditions and other
environmental conditions.
5. Check for proper lighting of indicators (for models with a set
indicator.)
Never disassemble or repair the Sensor.

Environment
24 VDC
Blue

Note:

The residual voltage of the DC 2-wire model is 5 V. Check


the operating voltage of the relay.

DC 3-wire Models
Connection to S3D2 Sensor Controller
Operation can be reversed by selecting the signal input selector of the S3D2.

Blue 0 V
Black OUT
Brown +12 V

S3D2

Water Resistivity
Do not use the Proximity Sensor underwater, outdoors, or in the
rain.
Operating Environment
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained.
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).

Connecting Load to DC 2-wire Sensor


Refer to the following before using DC 2-wire Proximity Sensors.
Surge Protection
Although the Proximity Sensor has a surge absorption circuit, if
there is any machine that has a large surge current (e.g., a motor or
welding machine) near the Proximity Sensor, connect a surge suppressor to the machine.

Cable Extension
Standard cable length is less than 200 m.
The tractive force is 50 N.

11

E2EM

E2EM
Leakage Current
When the Proximity Sensor is OFF, the Proximity Sensor has leakage current. In this case, the load is imposed with a small voltage
and the load may not be reset. Before using the Proximity Sensor,
make sure that this voltage is less than the load reset voltage.
Countermeasures Against Leakage Current
Connect a bleeder resistor as the bypass for the leakage current so
that the current flowing into the load will be less than the load reset
current.
Load

Bleeder resistor R

VS

Refer to the following to calculate the bleeder resistance and the allowable power of the bleeder resistor.
R x VS/(iR iOFF) (k)
P > VS2/R (mW)
P: The allowable power of the bleeder resistor. (The actual power
capacity of the bleeder resistor must be at least a few times
larger than the allowable power of the bleeder resistor.)
iR: Leakage current of the Proximity Sensor (mA)
iOFF: Load reset current (mA)
It is recommended that 15 k max./450 mW min. for 12 VDC and
30 k max./0.1 W min. for 24 VDC be used.
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.

12

WARRANTY
OMRONs exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if
specified) from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NONINFRINGEMENT,
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT
THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.

LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR
COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRONS ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.

SUITABILITY FOR USE


THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING
SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH
PURPOSES. Please refer to separate catalogs for OMRONs safety rated products.
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customers
application or use of the product.
At the customers request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to
the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end
product, machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all
possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT
THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

PERFORMANCE DATA
Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may
represent the result of OMRONs test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to
the OMRON Warranty and Limitations of Liability.

CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.

DIMENSIONS AND WEIGHTS


Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

ERRORS AND OMISSIONS


The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.

PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the users programming of a programmable product, or any consequence thereof.

ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.


To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.

Cat. No. D090-E1-02

In the interest of product improvement, specifications are subject to change without notice.

OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022/Fax: (81)75-344-7107

Printed in Japan