ESP Failure Analysis of Forties Experience Apache

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14
At a glance
Powered by AI
Failure analysis has helped identify root causes of failures and provided recommendations to improve ESP runlife. Some key improvements include implementing fit-for-purpose sand control and modifications to ESP electrical systems and bearings.

Failure analysis has driven improvements like implementing sand control measures to address sand related failures, modifying ESP electrical systems to address motor and electrical failures, and bearing upgrades to address bearing wear issues.

Improvements driven by failure analysis include implementing sand control measures, modifying ESP electrical systems with features like sine wave filtering and higher viscosity motor oils, and bearing upgrades with features like keyless bearings and full bearing housings.

FORTIES ESP

FAILURE ANALYSIS
EXPERIENCE
2014 EUALF

INTRODUCTION
Dismantle Inspection and Failure Analysis (DIFA) has driven a number of key
ESP improvements for Apache by properly establishing failure mode and
providing good, workable recommendations. Establishing the correct root
cause is ultimately where the value lies in this process.
This presentation will look at the following:

How has failure analysis benefited Apaches Forties Field over the past 10
years?
How can improved identification of true root cause of failure help to
improve ESP runlife?

AGENDA

Forties Field
DIFA driven improvements
ESP failure by categories
DIFA standard API 11S1
DIFA developments
Trends and challenges
Additional analysis
Improvement opportunities

FORTIES FIELD

5 platforms, one satellite platform, one


subsea tieback: Forties (A, B, C, D, E, FASP
and Bacchus)

190+ ESP installations in Apache era

~60 ESP wells, 35 gas lifted wells and


three subsea gas lifted wells.

Production potential of 51Mbd

~43% of field production through ESPs.

ESP runlife on upward trend thanks to


high efficiencies, good operational
procedures, incentivised contract with
service provider, more focus on ESP
reliability and DIFA.

DIFA DRIVEN IMPROVEMENTS


ESP electrical /
motor failures

Sand related
well failures

MLE damage
during
installation/
operation

ESP failure due


to sand fall back
/ pump bearings
failing

Keyless pump
bearings,
minimum sand
lift speeds

Full bearing
housing
pumps, adv.
Protector head
and shedder in
top of pump

MLE tensioner

Implementation of fit
for purpose sand
control

Sinewave filtering,
power quality
metering, more
viscous motor oil and
mine duty motors.

ESP FAILURES BY CATEGORY

Manufacturing and Electrical (design)


cover motor/general electrical failures
Green underline considers problem to
be eradicated with implemented
measures under present conditions
Reservoir covers ESPs that did not fail;
watered out etc.
Awaiting 13 DIFA reports and root
causes Reason for pull mainly
electrical with 1 elective pull.

DIFA STANDARD (API 11S1)


Most ESP vendors use recommended practice API 11S1 as a guide which provides a
good framework to ESP dismantle. Some of the key points to consider are as follows:
Pros
Comprehensive enough to cover ESP dismantle in detail
Ensures comments are recorded at each step in a structured and methodical
manner
Provides details of additional information required prior to starting any
dismantle/failure analysis
Cons
Does not give guidelines for lab analysis upon finding any unknown substances in
pump
Does not offer guidelines on root cause analysis which is left to the failure analyst
Can direct the analysis towards the cause of the system failure rather than that of
the component initiating the path to failure

DIFA DEVELOPMENTS

Better understanding of failure modes


Schlumberger feeding back to engineering
Schlumberger/Apache have been
routinely carrying out lab analysis on
foreign items found in pulled ESP systems
Usable and focused recommendations in
reports
Excellent detail in explanation of root
cause
Penetrator system suppliers providing
comprehensive tear down reports upon
discovery of system failures
Attention to the ESP lifecycle in every
report
Preliminary dismantle findings available
upon viewing equipment

TRENDS AND CHALLENGES


Electrical failures have been the most common failure mode, particularly
motor failures, since the widespread implementation of sand control.

Initial DIFA findings from motor failures


recommended using higher viscosity oil and
add one snap ring per rotor
Further succession of motor failures and
general electrical failures prompted an
investigation into electrical power quality
Common themes in failed motors
prompted further analysis to be carried out
on bearings:

Lab analysis of oil


Specialist analysis of bearing assemblies

ADDITIONAL ANALYSIS - ELECTRICAL


Electrical power study and lab testing carried out by specialist consultants MagneyGrande and David Shipp of Eaton.
Test set up to mimic offshore installation using typical
medium voltage VSD, tuneable sinewave filter (SWF) and
power quality meter.

10

Findings concluded addition of SWF eliminated high


frequency voltage and current
SWF helped balance motor current
Power quality meter will also allow for monitoring
therefore better operation of ESPs
Power quality meter will prove helpful for determining if
power quality played a role in system failure
identification of root cause

Without SWF

With SWF

ADDITIONAL ANALYSIS - BEARINGS


Expert bearing investigation carried out by Andrew Marshall of Scots Bearings.

11

Findings indicated mechanical wear rather than


previously suspected electrical
Sample oil analysis from test bearings showed kinematic
viscosity to be lower than the data sheets stated
Root cause of damage was determined to be poor
lubrication between surfaces
Reduction in hydrodynamic film could be caused by:

Increase surface roughness of bearing mating


surfaces

Mixing of oil during filling process


Recommendation: #6 oil deemed to be adequate as long
as it is not diluted i.e. no less than 220cSt @40degC
(agrees with SLB earlier recommendations)

Staining etched to
raceway surface

Radial scoring
circumferential
across rolling contact
zone

IMPROVEMENT OPPORTUNITIES

12

More detailed analysis of failure trends (like


bearing trend)
Avoid just accepting a higher spec without
attempting to find root cause
Understanding of the cause of electrical failures
still remains one of the weakest parts of the DIFA
process
DIFA reviews between SLB and Apache to tackle
divided opinion
Inclusion in the DIFA report of the Apache cause
analysis map drafted by the offshore team as part
of plant upset report (PUR)

IMPROVEMENT OPPORTUNITIES
Apache PUR Cause Map
Actions items
shown in green

Interventions /
observations
shown in red

13

ACKNOWLEDGEMENTS

14

You might also like