LINEAR SLOT DIFFUSERS

BETA
i n d u s t r i a l
PRODUCTS CATALOGUE

PRODUCT BULLETIN

BETA
i n d u s t r i a l
Dubai Head Office:
Tel: +9 71 4 706 9777
Fax: + 971 4 706 9787

Tel: +971 2 645 0107


Fax: +971 2 645 0167
Email:[email protected]

P.O.Box 50708, Dubai


United Arab Emirates

w w w. be t ag . c om

BETA
I n d u s t r i a l

index

>>

1-2

>>

3-4

>>

PERFORMA NCE DATA

5-11

LINEAR SLOT DIFFUSERS

>>

Flush - mounted linear diffuser.

>>

Available in 1 to 6 slots.

>>

Standard lenght : 1000mm & 2000mm per section. Other


lengths are availabe on request.

>>

180 fully adjustable air flow pattern by means of two air

>>

Available with hit-and-miss damper which controls the air flow

deflections per slot.

rate without affecting the air flow pattern; can be used as an


equalizing grid.

>>

For each slot the air deflector and hit-and-miss damper are
individually adjustable.

>>

Removable flange type end cap allows extending or


shortening slot diffuser line without replacing existing pieces.

>>

The deflector and the hit and miss damper are powder coated
with black color as standard.

dimensions & discharge details

Neck Size
78
Horizontal Left and
Horizontal Right Discharge

5,5

5,5

9,7

27,3

55

9,1

Hit-and-miss damper

28,5

19,5

2,6

18,1

Deflector

28,5

Flange Size

Neck Size

Neck Size

78

78

9,7

5,5

5,5

5,5

9,1

9,7

18,1

Flange Size

01

28,5

19,5

Flange Size

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

28,5

2,6

28,5

2,6

19,5

18,1
Deflector

Deflector

28,5

27,3

27,3

55

55

9,1

Horizontal Left and


Vertical Discharge

5,5

LINEAR SLOT DIFFUSERS

linear slot diffuser fixing details

Available types of finishing:


>> Natural anodized aluminium finish
>> Powder coated to RAL codes
Standard Neck & Flange Sizes:
Standard slot size 20mm

Plenum
By Others

Adjustable Screw
By Others

Hanging Bridge bracket


By Others

Supporting Clamps

False Ceiling
By Others
Slot Diffuser

No. of Slots

1 Slot

2 Slot

3 Slot

4 Slot

5 Slot

6 Slot

Neck Size: (mm)

47

85

123

161

199

237

Flange Size: (mm)

76

114

152

190

228

266

ORDERING SYSTEM
TYPE

CURVE

SIZE

FINISH
RAL:

POWDER COATED FINISH AS PER RAL CODES

ANODIZED: ANODIZED ALUMINIUM FINISH

LENGTH

NUMBER OF SLOTS

CURVE : IF CURVE REQUIRED


(ONLY RLD)

CURVE

SLD: SLPPLY LINEAR DIFFUSER WITH DEFLECTORS


WITH HIT & MISS DAMPER

EXAMPLE:SLD

02

2000 3S RAL 9016

RLD:RETURN LINEAR DIFFUSER WITHOUT


DEFLECTORS WITH SQUARE SHAPE PUNCHED STRIP.

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

LINEAR SLOT DIFFUSERS


ACCESSORIES
1 - End Caps (F1)
(A) - L-Shaped End Caps

L-shape flange : 30 55mm, available in


different lengths to match slot diffuser width.
Fixed at the end of slot diffuser line.
Very easy to install and remove. Gives
flexibility to extend or shorten slot diffuser
without replacement of existing pieces.

30
STRAIGHT JOINT END CAP

Supplies FREE with fixing screws.


Hole for Self-tapping screw

Available in 1 to 6 slot

(B) -Mitered Corners End Caps

46 O

44

30

Hole for Self-tapping screw

2 - Corner pieces (F2)


Available in 1 to 6 slot
Available in any combination of X.Y
(X-300 mm Y=300 mm as standard )
: 45 , 90 , 135

3 - Mitered ends (F3, F4)


Standard lengths are available in mitered
ends of 45 and 135

03

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

MITERED JOINT END CAP

ACCESSORIES

F5

1m
ete

Minimum radius = 1000mm

Mi
n im
um

Ra

d iu

s:

For curved items,


different section
used as below
drawing.

NECK SIZE = 123 mm

55

Type RLD 3S
without deflectors
with hit-and- miss dampers
FLANGE SIZE = 152 mm

04

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

LINEAR SLOT DIFFUSERS


PERFORMANCE DATA

PRODUCTS TESTING
The following tables include the results of tests conducted on three linear slot diffusers. The test results include Noise Criteria
(NC), static pressure versus air flow, throw and Ak. The diffusers were selected and supplied by Beta In October 1991. The
extrapolations and interpolation were made to cover a full range of sizes and parameters according to ETL testing laboratories Inc. who made the tests.

TEST METHOD

The air diffusers were tested in accordance with the Air diffusion council test code for grilles, registers and diffusers n o. ADC
1062.GRD.84, the test was conducted in ETL testing laboratories.

The diffusers were installed in the ADC facility and supplied with measured volume of air. The static pressure was measured
(1-1.5) duct diameters upstream of the diffuser inlet.

Acoustical data was obtained employing Bruel and Kjaer digital frequency analyzer, and analyzed by computer. Sound power
levels were plotted on a graph of noise criteria curves which are in the ADC codes.

NOTES:

05

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

PERFORMANCE DATA

SLD/RLD - SUPPLY

VERTICAL DISCHARGE

*S.I. UNITS
16 MM

SLOTS L/S per meter

A
AK
K

24
35
47

2.4
3.0
4.3

15
19
28
34

7.6

41

83
94

11.31
14.97

24

0.31

2.4

16

47

1.19

5.2

20

71

2.66

6.4

28

8.2
10.0

40
46

Pt

0.58
1.32
2.34
0.008 3.66

118

4.77
7.42

142

10.72

54

165

14.69

59

47
71

0.56
1.23
2.19
3.41

3.0
5.2
6.7
8.5

16
20
28
36

0.36
0.79
1.40
0.030 2.18

142

4.92

10.3

43

165
189

6.67
8.73

71

0.75

3.15
4.27
5.59
0.48
0.84
1.32
0.037 1.91
2.59
3.38
4.32

0.017

0.024

45
51

48
53
4.3

16

94

1.31

5.2

20

118

2.06

6.4

28

2.98

8.2

33

4.05

10.3

0.030

165
189
212

5.28
6.75

94
118
142
165

0.037

189

39

41
46

0.88
1.34
1.94

4.6
5.5
7.0

15
19
25

2.66

8.5

31

3.45

10.0

35

212

4.36

39

236

5.39
0.95

4.6

44
15

1.39

5.8

19

1.91

7.0

23

2.45

8.8

28

3.14
3.89
5.56

10.7

31
34
44

118
142
165
189

0.043

212
236
283

0.046

0.054

25 MM

Th

NC

2.1

<15

2.7
3.7

15
22
0.010

Pt

Th

NC

0.37
0.84
1.50

1.8
2.4
3.1

<15
<15
18

5.5

27

2.34

4.9

22

7.0

33
36
41
<15

3.41
4.63
6.13
0.13

6.4

1.8

26
29
33
<15

16

0.49

4.0

<15

5.8

22

5.2

18

7.6
9.1

32
37

1.09
1.95
3.04

7.0
8.2

26
30

2.1
4.6

0.026

43

4.39

47

6.02

2.7
4.6
6.1
7.9

<15
16
22
29

0.23

9.4

34
38

0.51
0.90
1.40

2.4
4.0
5.5
7.3

34

2.02

8.5

2.73

4.0

38
42
<15

4.9

16

5.8

22

7.6

26

9.4

0.038

3.58
0.31

0.046

<15
<15
18
23
27
30

3.7

34
<15

0.54

4.6

<15

0.84
1.22

5.2
7.0

21

18

31

1.66

8.5

25

33

2.16

26

2.76
0.36
0.55

4.0
4.9
5.8

30
<15
<15
16

0.56
0.86
1.24
1.70

4.3
5.2
6.4

37
< 15
15
20

7.9

25

2.21
2.79
3.45

9.1

0.61
0.89
1.22
1.57
2.01
2.49
3.56

AK

0.79
0.058

1.09

7.3

20

28

1.41

8.2

22

1.79
2.21

4.3

31
35
< 15

5.2

15

6.4

18

8.2

22
25
27

9.8

0.068

35

25
28

0.39

4.0

<15

0.57
0.78

4.6

<15
<15

1.00

5.8
7.6

1.28

8.9

20

1.59
2.28

CONDITIONS

SYMBOLS

06

AK

5.33
7.24
9.58
0.20
0.76
1.70
0.021 3.05
4.75
6.86
9.40

142

0.91
2.06
3.66

6.1

118

NC

8.33

94

Th

5.72

94

Pt

71

59

0.006

20 MM

L/S

: Air volume in liter per second.

* Supply

Ak

: Effective face area in meter Square per 1000 mm.

* Vertical discharge flow pattern.

Pt.

: Total pressure in millimeters water gauge.

* Noise Criteria values are based on(10 db) room attenuation.

Th.

: Throw in meters.

* Damper is fully open.

NC

: Noise Criteria.

* Throw values are based on terminal velocity of 0.50 m/s

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

18
22
28

SLD/RLD - SUPPLY
HORIZONTAL DISCHARGE

*S.I. UNITS

16mm
SLOTS L/S per meter

Ak

Pt

Th

NC

Ak

18

0.51

0 .3-1.2-2.1

<15

35

2.78

1.2-2.1-3.3

31

1.78 0.9-1.8-3.0

25

1.44

0.9-1.5-2.7

20
26

4.97

1.8-3.0-4.6

41

3.18 1.5-2.7-4.3

33

2.04

1.2-2.4-4.0

59

7.73

2.7 -4.3-7.0

48

4.95

2.4-4.0-6.4

38

3.17

2.1-3.7-5.8

30

71

11.11

4.0-5.8-8.5

54

7.11 3.7-5.2-7.9

43

4.55

3.4-4.6-7.3

34

24

0.39

1.2-1.8-2.7

16

0.25

0.9-1.5-2.4 <15

0.16

0.9-1.2-2.1

<15

47

1.59

1.5-3.3-5.5

25

1.02

1..2-3.0-5.2

20

0.65

0.9-2.7-4.6

16

3.58

1.8-4.0-7.3

39

2.29

1.5-3.7-6.7

31

1.47

1.2-3.4-6.1

25

6.27

2.7-6.1-9.4

50

4.01

2.4-5.5-8.5

40

2.57

2.1-4.9-7.9

32

71

0.004

0.001

0.005

0.014

0.006

0.018

118

9.92

4.0-7.6-11-.0

56

6.35

3.7-7.0-10.1

45

4.06

3.4-6.4-9.2

36

47

0.80

1.2-1.8-3.7

21

0.51

0.9-1.5-3.4

17

0.33

0.9-1.2-3.1

<15

71

1.75

1.8-3.0-6.1

29

1.12

1.5-2.7-5.5

23

0.72

1.2-2.4-5.2

18

3.09

2.1-4.3-7.6

39

1.98

1.8-4.0-7.0

31

1.27

1.5-3.7-6.4

25

94

0.018

0.022

0.028

118

4.84

3.0-6.1-9.7

48

3.10

2.7-5.5-8.8

38

1.98

2.4-4.9-8.2

30

142

7.38

4.3-7.3-11.3

53

4.72 4.0-6.7-10.4

42

3.02

3.7-6.1-9.5

34

71

1.00

1.5-2.1-4.9

24

0.64

1.2-1.8-4.6

19

0.41

1.9-1.5-4.3

15

1.12

1.5-3.0-5.5

25

0.72 1.2-2..7-5.2

20

1.75

1.8-4.0-6.7

30

1.12 1.5-3..7-6.1

24

2.7-5.5-8.5

1.75

118

0.024

2.73

1.8-3.3-6.1

31

2.1-4.3-7.3

38

0.030

0.038

142

3.97

3.0-6.1-9.4

44

2.54

35

1.63

165

5.36

4.0-7.6-11.3

50

3.43 3.7-7.0-10.4

40

2.20 3.4-6..4-9.5

94

1.34

1.8-2.4-5.5

26

0.86

1.5-2.1-4.9

21

0.55 1.2-1..8-4.6

17

118

2.06

2.4-3.7-6.7

33

1.32

2.1-3.4-6.1

26

0.84 1.8-3..1-5.5

21

28
32

2.98

3.0-4.6-7.6

38

1.91

2.7-4.3-7.0

30

1.22 2.4-4..0-6.4

24

3.7-6.4-9.7

43

2.59

3.4-5.8-8.8

34

1.66 2.8-5..2-7.9

27

189

5.31

4.3-7.6-11.0

49

3.40 4.0-7.0-10.1

39

2.18 3.7-6..4-9.2

31

118

1.59

1.8-2.7-5.5

28

1.02

1.5-2.4-4.9

22

0.65 1.2-1..8-4.3

18

142

2.27

2.4-3.7-6.7

35

1.45

2.1-3.4-6.1

28

0.93 1.8-3..1-5.5

22

3.09

3.0-4.9-7.9

39

1.98

2.7-4.6-7.3

31

1.27 2.4-4..0-6.7

25

4.05

3.3-6.4-10.0

44

2.59

3.0-5.8-9.1

35

1..66

.
2.7-5.2-8.2

28

48

3.30

3.7-7.0-10.4

38

.
2 .11

.
3.4-6.4-9.5

30

0.030

165

0.037

5.16

4.0-7.6-11.3

0.038

0.046

0.048

0.058

SYMBOLS

NOTES

L/S

: Air volume in liter per second.

Ak

: Effective face area in meter Square per 1000 mm.

* The large throw values are based on the minimum terminal velocity of 0.25m/Sec.
* The middle throw values are based on the middle terminal velocity of 0.50 m/Sec.
* The small throw values are based on the maximum terminal velocity of 0.75m/Sec.

Pt.

: Total pressure in millimeters water gauge.

Th.

: Throw in meters.

NC

: Noise Criteria.

Supply

* Horizontal Discharge flow pattern


* Noise Criteria values are based on (10 db) room attenuation.

07

2.4-.4.9-7.9

4.05

142

CONDITIONS

*
*

NC

0.79 0.3-1.2-2.4

189
212

Pt

23

165

NC

0.6-1.5-2.7

94

Th

1.23

94

Pt

25mm
Th

24

47

Ak

20mm

Damper is fully open.


The tested specimens were of 1000 mm length

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

SLD/RLD - RETURN

PERFORMANCE DATA
16mm
SLOTS

L/S per meter

Ps

NC

35

3.38
5.95
9.13
13.81
18.66
3.97
5.80
7.19
11.11
15.88
3.97
6.19
8.94
12.14
20.16
6.34
8.61
11.11
16.78
24.92
4.44
7.86

24
31
40
49
55
24
31
36
45
53
25
33
39
46
54
28
35
40
48
55
26
35

12.30
17.66
24.02
6.19
9.64
13.89
18.86
24.69

43
48
55
29
36
44
49
55

47

59
71
83
71
83
94

118
142
94
118

142
165
212
142
165
189

236
283
142
189

236
283
330
189
236

283
330
378

*S.I. UNITS

20mm
Ps
NC

Ps

NC

2.16
3.81

1.38
2.44

15
20

19
25

25mm

5.84

32

3.74

26

8.84

39

5.66

31

11.94

44

7.64

35

2.54
3.71
4.60
7.11

19
19
25
29
36

1.63
2.37
2.94
4.55

15
20
23
29

10.16
2.54

42
20

6.50
1.63

34
16

3.96

26

2.53

21

5.72

31

3.66

25

7.77
12.90

37
43

4.97
8.26

30
34

4.06

22

2.60

18

5.51
7.11

28
32

3.53
4.55

22
26

10.74

38

6.87

30

15.95
2.84
5.03

44
21
28

10.21
1.82
3.22

35
17
22

7.87

34

11.30
15.37

38
44

3.96
6.17

23
29

5.04
7.23
9.84
2.53
3.95

: Air volume in liter per second.

P/s

: Negative static pressure in milimeters water gauge.

NC

: Noise Criteria.

8.89

35

5.69

28

39
44

7.72
10.11

31
35

CONDITIONS
* Return
* Damper is full open.
* Noise Criteria values are based on(10 db) room attenuation
* The tested specimens were of 1000mm length

08

18
23

12.07
15.80

SYMBOLS
L/S

27
30
35

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

PERFORMANCE DATA

SLD/RLD - SUPPLY
VERTICAL DISCHARGE

* IMPERIAL UNITS
3/5

Th

NC

Ak

23

8
10

<15
16

30

0.144

14

23

0.225

19

29

0.023
0.052
0.092
0.025 0.144

0.328

25

36

A
Akk

15

38

0.020

45
53

0.455
0.589

60

0.013

<15

30

0.047

17

17

60

0.105
0.188

21
28

23
35

75

0.292

33

41

90

0.422

49

105
30

0.578
0.022
0.048
0.086

10
17
22

54
<15
17
23

75

0.134

29

31

90
105

0.194
0.263

34

38
43

120

0.344

45

0.030

0.053

45
60

0.077

60

75

0.097

90
105
120
135

<15

0.052

18

17

0.081

22

23

0.117

28

28

0.159
0.208

34

34
36

<15

<15

25

28
33

15
21

17
22

0.126

26

26

0.067
0.120
0.187

0.270
0.370
0.014
0.031
0.096 0.055
0.086
0.124
0.168
0.220
0.019
0.033
0.121 0.052
0.075
0.102
0.133

0.038

15

<15

0.055
0.075

19
23

16
19

0.097
0.123
0.153
0.219

30
34

23
26
29
39

0.024
0.035
0.173 0.048
0.062

180

23
26
30

11

75

150

18

21

0.006

150

135

17

0.086
0.113
0.150

0.012
0.039
0.082

0.087
0.110
0.136

120

0.061

<15
18

30
34
39

0.138

<15
<15
<15

<15

33

90

0.079
0.098
0.140

32
37

30

15

39
43
<15
<15

20

18

26
31

25
30
34

0.818

0.266

1.190

0.009
0.024
0.038

7
14
18

0.049
0.081

23

0.142
0.009

<15

30
11

0.020

14

0.043

16
22

<15
18

0.077

28

22

<15
18

25
31

22
27
29

0.102

33
<15
<15

0.121
0.013
0.021
0.039

23
13
15
19

26
<15
<15
15

21

16

26

21

0.051

23

17

30

24
27
31

0.069

27

19

14

<15

0.017

13

<15

17

<15
<15
18
21
23

0.026
0.033

15

21
27

19

<15
<15

0.048

24
29

17

32

31

1.823

0.074
0.111

2.145

0.058

22
25

0.067
0.106

CFM

: Air volume in cubic feet per minute.

* Supply

Ak

: Effective face area in meter Square feet per foot.

* Vertical discharge flow pattern.

Pt.

: Total pressure in inches water gauge.

* Noise Criteria values are based on(10 db) room attenuation.

Th.

: Throw in feets.

* Damper is fully open.

NC

: Noise Criteria.

* Throw values are based on terminal velocity of 75 fpm


* The tested specimens were 3ft length

09

24
27

0.036

16

1.500

34
<15
<15
16
20

<15
<15

19

14
17

28

0.109

38
13

31

0.194

CONDITIONS

SYMBOLS

NC

7
8
11

15
19

0.136
0.172
0.213

105

0.031

Th

20
26

135

<15
18

Pt
0.010
0.023
0.041

0.008
0.030

23
29

120

9
12

At

23

0.077
0.105

0.118

<15

29

16
19

105

NC

23

0.170
0.022
0.034
0.147 0.049
0.067

90

Th

18

41
<15
16

75

48
15

0.066

0.210
0.285
0.377

0.266
0.034
0.053

60

40
46

15

45

Pt

Pt
0.036
0.081

SLOTS CMF Per Foot

4/5

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

16
18
25

SLD/RLD - SUPPLY
HORIZONTAL DISCHARGE
*IMPERIAL UNITS

3/5
SLOTS CFM Per Foot

Ak

15
23
30

0.014

17

0.109

4-7-11

26

0.195

6-10-15

36

0.305
0.438

9-15-23
14-19-29

NC

0.031

1-4-8

<15

0.070

Ak

0.020

0.195

34

0.125

7-12-19

27

49

0.280 12-17-26

39

0.179

10-15-23

31

18

0.010

3-5-8

<15

0.006

3-5-7

<15

0.040

4-10-17

16

0.026

3-9-15

<15

20

0.018

0.045

8-13-21

0.023

0.056

0.045

3-5-9

17

0.080

5-8-13

23

0.141

6-13-25

34

0.090

5-12-22

27

0.058

4-11-20

22

60

0.247

10-20-30

45

0.158

8-18-28

36

0.101

7-16-25

29

75

0.391

14-25-35

51

0.250

12-23-33

41

0.160

10-21-30

33

30

0.031

4-6-12

16

0.020

3-5-11

<15

0.013

3-5-10

<15

0.044

5-9-18

19

0.078

6-13-23

27

0.069

60

0.058

6-10-20

0.122

7-15-25

24
34

0.072

0.090

0.028

4-8-15

15

0.050

5-12-21

22
27

75

0.191 10-20-32

43

0.122

9-18-29

34

0.078

8-16-26

90

0.291

15-24-36

48

0.186

13-22-34

38

0.119

12-20-31

30

45

0.039

5-7-17

19

0.025

4-6-15

15

0.016

3-5-13

<15

6-11-19

26

0.108

7-15-24

33

90

0.156

10-20-30

105

0.211

14-25-37

60

0.053

6-8-18

21

0.034

5-7-16

17

0.022

4-6-14

<15

75

0.081

8-13-22

28

0.052

7-11-20

22

0.033

6-10-18

18

0.117

10-16-25

33

0.075

9-14-23

0.048

8-12-21

21

0.159

13-21-32

38

0.102

11-19-29

30

0.065

10-17-26

24

120

0.209 15-25-36

44

0.134

13-23-33

35

0.086

11-21-30

28

75

0.063

6-10-18

23

0.040

5-8-16

18

4-7-14

<15

0.089

8-12-23

30

0.057

7-11-20

24

0.122

10-17-27

34

0.078

9-15-24

27

0.159

11-21-33

39

0.102

10-19-30

0.130

12-23-34

75

0.069

90

0.078

0.098

105

0.118

0.203 13-25-37

0.028

4-9-16

17

0.044

5-11-20

21

31

0.064

8-16-25

25

36

0.086

10-21-31

29

0.044

5-10-18

21

0.069

6-13-22

26

39

0.100

9-18-28

45

0.135

12-23-34

0.097

0.123

0.148

43

26

0.121

0.154

0.026
0.036

6-10-18

19

0.050

8-13-21

22

31

0.065

9-17-27

25

34

0.083

11-21-31

27

0.185

SYMBOLS

NOTES

CFM

: Air volume in cubic feet per minute.

Ak

: Effective face area in meter Square feet per feet.

* The large throw values are based on the minimum terminal velocity of 50 fpm.
* The middle throw values are based on the middle terminal velocity of 75 fpm.
* The small throw values are based on the maximum terminal velocity of 150 fpm.

Pt.

: Total pressure in inches water gauge.

Th.

: Throw in feet.

NC

: Noise Criteria.

CONDITIONS
Supply

* Horizontal Discharge flow pattern


* Noise Criteria values are based on (10 db) room attenuation.

10

NC
<15

43

5-11-19

120
135

*
*

Th
1-3-7

21

0.016

90

Pt

29

0.063
0.036

1
Th

Pt

3-6-10

15

45

3-6-9

Ak

0.125 5-9-14

30

105

NC

1-4-8

45

60

Th

0.048

38

45

Pt

4/5

Damper is fully open.


The tested specimens were of 3ft length

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

SLD/RLD - RETURN

PERFORMANCE DATA
3/5
SLOTS

CFM per foot

Ps

NC

23

0.133
0.234
0.359
0.544
0.734
0.156
0.228
0.283
0.438
0.625
0.156
0.244
0.352
0.478
0.794
0.250
0.339
0.438
0.661
0.981
0.175
0.309

19
26
35
44
50
19
26
31
40
48
20
28
34
41
49
23
30
35
43
50
21
30

0.484
0.695
0.945
0.244
0.380
0.547
0.742
0.972

38
43
50
24
31
39
44
50

30

38
45
53
45
53
60

75
90
60
75

90
105
135
90
105
120

150
180
90
120

150
180
210
120
150

180
210
240

*IMPERIAL UNITS
1
4/5
Ps
NC
Ps
NC

0.085
0.150

15
21

0.054
0.096

0.230

28

0.147

22

0.348

35

0.233

28

0.470

40

0.301

32

0.100
0.146
0.181
0.280

15
21
25
32

0.064
0.093
0.116
0.179

<15
17
20
26

0.400
0.100

38
16

0.256
0.064

30
<15

0.156

22

0.100

18

0.225

27

0.144

22

0.306
0.508

33
39

0.196
0.325

26
31

0.160

18

0.102

<15

0.217
0.280

24
28

0.139
0.179

19
22

0.423

34

0.271

27

0.628
0.112
0.198

40
17
24

0.402
0.072
0.127

32
<15
19

0.310
0.445
0.605
0.156
0.243
0.350
0.475
0.622

30
34
40
19
25
31
35
40

0.198
0.285
0.387
0.100
0.156
0.224
0.304
0.398

SYMBOLS
CFM

: Air volume in cubic feet per minute.

P/s

: Negative static pressure in inches water gauge.

NC

: Noise Criteria.

CONDITIONS
* Return
* Damper is full open.
* Noise Criteria values are based on(10 db) room attenuation
* The tested specimens were of 3ft length

11

<15
17

ALL DETAILS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE

24