FT-Delta en Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

FT

Measuring Force Sensors Rigid

Six series
Nano, Mini, Gamma, Delta,
Theta, Omega

Range of measurement,
force
36 N .. 40000 N

Range of measurement,
moment
0.5 Nm .. 6000 Nm

Application example

Robot-supported chamfering of round rods

FT-Delta 6-Axis Sensor


PZN-plus 64 3-Finger Centric Gripper

408

www.schunk.com

FT
Measuring Force Sensors Rigid

Force Sensor
6-axis sensor

Area of application
for precise measuring of forces and moments in all three spatial
directions

Your advantages and benefits


Six sizes
with different ranges of measurement
High degree of resolution of measured values
and fast data transfer for virtually real-time force monitoring
Robust design
due to a higher overload range
Rotation and translation of the coordinates system
in all three directions
Robust design and easy to operate
for a long tool life and reduced set-up costs

General information on the sensor element


Working principle
Monolithic measuring element with three measurement harnesses at an angle of
120. Each harness is fitted with two semiconductor strain gauge bridges which
record the deformation in micrometers.
Overload protection
In all six axes, overloads to the values specified above are permitted without the
sensor having to be recalibrated. Additional overload bolts protect the sensor from
mechanical damage.
Material
Aluminum, stainless steel

Ambient temperature
0 C to 70 C, calibrated at 22 C
Measuring accuracy
less than +/- 1% of the upper range value at 22 C
Temperature compensation
Hardware side as standard
Splash protection
IP 65 on request
Warranty
12 months

www.schunk.com

409

FT
Measuring Force Sensors Rigid

FTD DAQ F/T system


The 6 axis force-torque sensor FTD is available in two different configurations, depending on the size of the sensor:
Sensor with integrated interface board
Delivered as standard:
Sensor with interface board (from Gamma size)
Sensor cable (10 m)
Power supply box
Connecting cable to the PC (2 m)

Sensor with external interface board


Delivered as standard:
Sensor without interface board (sizes Nano and Mini)
Sensor cable (1.8 m)
Power supply box with integrated interface board
Connecting cable to the PC (2 m)

Description of the individual components


6-axis force-torque sensor
Strain gauges (DMS) measure the strains applied in all six degrees of freedom
(Fx, Fy, Fz, Tx, Ty and Tz). The DMS signals are amplified in the sensor. Because
of the size, the interface board for the Nano and Mini series is not located in the
sensor, but in the power supply box (IFPS).

Power supply box


The power supply box contains the voltage transformer which converts the PCs 5 V
power supply into a voltage which can be used by the sensor.
In the Nano and Mini system the interface board is integrated into the box as well
as the voltage transformer.

Sensor cables
With the Nano and Mini sensors, the sensor cables are soldered into the sensor. A
connector is located on the sensor housing of larger sensors to fix the sensor
cable.
The highly-flexible sensor cable protects the sensor signals from electric fields and
mechanical strains.

Connecting cable to the PC


The highly-flexible connecting cable carries the PC voltage to the power supply box
and the sensor signals to the DAQ card.

Interface board
The interface board converts the strain gauge signals into a signal which can be
used by the DAQ card. To ensure optimum measurement results, the amplification
factors are adjusted in line with the sensor used. The sensor and the interface
board therefore form a single unit.

Data acquisition card (DAQ)


The DAQ card converts the sensors analog DMS signals into digital signals.
DAQ cards are available for a wide variety of BUS systems (PCI, cPCI, PCMICA,
USB, ISA).

DAQ F/T system for Gamma and larger sensors

DAQ-Card

power supply
DAQ cable 2 m

sensor with
interface
sensor cable 10 m

410

www.schunk.com

PCI, PCMCIA,
CPCI or USB
(has to be ordered separately)

FT
Measuring Force Sensors Rigid

DAQ cards
The DAQ cards available for the sensor are shown in the list below. If you are already using DAQ hardware it could be used in differential or single-ended mode. We recommend differential-ended mode for an optimum, low-noise measurement signal.
Available DAQ cards
ID
0322005
0322006
0322003
0322004
0322011

Designation
FTD-DAQ-N1CPCI
FTD-DAQ-N2CPCI
FTD-DAQ-N1PCMCIA
FTD-DAQ-N2PCMCIA
FTD-DAQ-M1PCI

Resolution
16-bit
12-bit
16-bit
12-bit
16-bit

Bus
cPCI
cPCI
PCMCIA
PCMCIA
PCI

Max. transmission rate


14.2 K datasets/second
28.5 K datasets/second
28.5 K datasets/second
28.5 K datasets/second
250 K datasets/second

 The max. transmission rate is dependent upon the overall speed of the computer system.

The analog measurement values issued by the sensor are amplified strains from the strain gauges (DMS) and not forces and moments. The software provided converts the
DMS signals into forces and moments. In order for the signals to be converted, all six DMS signals must be digitized by the DAQ card.

DAQ software
The DAQ F/T software provided contains Windows ActiveX components, a C library
and an example program.
Software features
The automation server ATIDAQFT is a Windows ActiveX component which carries out
the following functions:
Importing the calibration file
Configuring the sensor system
Converting the sensor signals which are read in via the DAQ card into forces and
moments
Supporting tool transformation

The ATIDAQFT server has been developed for use in an ActiveX environment.
The following programs are examples of those supported.
LabVIEWTM, Microsoft Visual BasicTM, Visual Basic for Applications and Visual C++TM
For other operating systems a C library is available with the same range of
functions.
Demo program
The Windows DAQ F/T demo program provides visual and numerical representations of forces and moments. A Windows operating system (Windows 95 or later)
is required. The Visual Basic 6.0 source code is used as an aid for creating additional application programs. A LabVIEW application program is currently being
developed.

DAQ F/T system for Mini and Nano sensors

DAQ-Card
power supply
DAQ cable
5m

PCI, PCMCIA,
CPCI or USB
(has to be ordered separately)

sensor
sensor cable 1.8 m

www.schunk.com

411

FT
Measuring Force Sensors Rigid

Stand alone controller, FTS version


The 6 axis force-torque sensor FTS is available in two different configurations, depending on the size of the sensor:
Sensor with integrated MULTIPLEX board
Delivered as standard:
Sensor with MULTIPLEX board (from Gamma size)
Sensor cable
Stand alone controller
Network cable

Sensor with external MULTIPLEX board


Delivered as standard:
Sensor without MULTIPLEX board (sizes Nano and Mini)
Sensor cable
MULTIPLEX box
MULTIPLEX cable
Stand alone controller
Network cable

Description of the individual components


6-axis force-torque sensor
Strain gauges (DMS) measure the strains applied in all six degrees of freedom
(Fx, Fy, Fz, Tx, Ty and Tz). The DMS signals are prepared on the MULTIPLEX board.
Because of the size, the MULTIPLEX board for the Nano and Mini series is not
located in the sensor, but in the MULTIPLEX box.
Sensor cables
With the Nano and Mini sensors, the sensor cables are soldered into the sensor.
A connector is mounted onto the sensor housing of larger sensors to fix the sensor
cable. The highly-flexible sensor cable protects the sensor signals from electric
fields and mechanical strains.

MULTIPLEX board
The MULTIPLEX board amplifies the strain gauge signals and issues them in multiplex form. To ensure optimum measurement results, the amplification factors are
adjusted in line with the sensor used. The sensor and the MULTIPLEX board therefore form a single unit. With the Nano and Mini sensors, the MINI MULTIPLEX
board is located in an extra box.
Stand alone controller
The stand alone controller is connected to the sensor or to the MULTIPLEX box. It
converts the multiplex-form DMS signals into forces and moments. Functions such
as tool transformation are implemented in the controller. Communication is carried
out via an RS-232 interface. The force and moment measurement values are
issued in the form of analog strains. Optically decoupled I/Os facilitate simple
integration into the machine control system.

FTS system

controller

sensor

412

standard cable
7.6 m

www.schunk.com

FT
Measuring Force Sensors Rigid

Sensor selection schematic


1. Calculating the expected forces and moments
The moment load is usually the determining factor when selecting a sensor. The
tool weight and the application process generate the forces which can act upon
the sensor in the form of moments. The moment is calculated from the force
applied (static and dynamic) multiplied by the lever arm. The lever arm is calculated from the distance from the point of application of the force to the sensors
reference point. At the design stage, forces and moments which could act upon the
sensor outside of normal operation also have to be taken into account.
2. Sensor pre-selection on the basis of the forces and moments
Please use the table below.
3. Determining the resolution
Check whether the sensors resolution matches your requirements. It is possible
that a sensor selected on the basis of the forces and moments does not meet the
requirements with respect to resolution.
The basic principle is the larger the range of measurement, the lower the resolution.

Example
The maximum expected force acting on the sensor is 98 N (10 kg).
This force acts on the sensor at a distance of 25 cm. The moment is therefore
24.5 Nm.
The FT-Delta-SI-330-30 is suitable for this application. (Range of measurement
330 N and 30 Nm). Overload safety is 230 Nm (Mxy).
Notes on robot applications
During a crash, extremely high forces and moments act on the sensor due to the
robots mass inertia and braking deceleration.
To protect the sensor in these situations, we recommend the use of an OPS or OPR
collision and overload protection device.

Brief overview of FT
Designation
Max. Fxy
Max. Mxy
Weight
Diameter
Height

[ N]
[ Nm]
[kg]
[mm]
[mm]

Nano
17
50
0.5
0.01
17
14.5

Nano
25
250
6
0.07
25
21.6

Nano
43
36
0.5
0.04
43
11.5

Mini
40
80
4
0.05
40
12.3

Mini
45
580
20
0.09
45
15.7

Gamma

Delta

Theta

130
10
0.25
75.4
33.3

660
60
0.91
94.5
33.3

2500
400
4.99
155
61.1

www.schunk.com

Omega
160
2500
400
2.72
156
55.9

Omega
190
7200
1400
6.35
190
55.9

Omega
250
16000
2000
30.0
254
95

Omega
331
40000
6000
43.0
254
107

413

FT
Measuring Force Sensors Rigid

How to order FTS sensors with stand-alone control


FTS-[sensor]-(cable) -

Mains plug
A - Australia
Y - Italy
T - Unterminated

D - Denmark
N - North America
E - European

I - India
U - United Kingdom

Stand alone controller model


CTL
16 bit controller
CON Controller compatible with 12 bit version
CTE
16 bit controller in Euro card version
Mux: Cable length to the MUX box
Standard length 7.6 m
For sensors without MUX box 0
Cable length to the controller
1.8 m is standard with Nano and Mini
Large sensors 7.6 m
Cable outlet
R: Radial standard for all sizes
A: Axial for Nano 17, Nano 25, Mini 40 and Mini 45
Size
Nano 17, Nano 25, Nano 43, Mini 40, Mini 45, Gamma, Delta, Theta, Omega 160, Omega 190,
Omega 250 or Omega 331

414

www.schunk.com

FT
Measuring Force Sensors Rigid

How to order FTD sensors


FTD-[sensor]-(cable) -

NO Without DAQ card


(DAQ card available from SCHUNK on request)

Cable length between the power supply box and the DAQ card
Standard length 2 m
M = M series connector
U = Open wires
Cable length between the sensor and the power supply box
Standard length 10 m for Gamma, Delta, Theta and Omega
Standard length 1.8 m for Nano and Mini
Cable outlet
R: Radial, standard for all sizes
A: Axial for Nano 17, Nano 25, Mini 40 and Mini 45
Size
Nano 17, Nano 25, Nano 43, Mini 40, Mini 45, Gamma, Delta, Theta, Omega 160, Omega 190,
Omega 250 or Omega 331

www.schunk.com

415

FT-Delta
Measuring Force Sensors Rigid

Product advantages
Wire eroded measuring element made from highstrength, stainless steel
Special overload bolts make the Delta an extremely
robust transducer
Up to 148-fold overload safety with respect to the
range of measurement
Measurement signal resistant to interference
due to use of silicium strain gauges
Silicium strain gauges provide a signal which is 75
times stronger than conventional foil strain gauges.
The silicium strain gauges reduce signal noise to
practically nothing.
Sensor also available in the following
protection classes
IP 60 dust-proof version
IP 65 splash-proof version, suitable for use in damp
environments
IP 68 immersion-proof version down to 10 m
For further information or drawings please feel free
to contact us. We will be happy to help.

Typical areas of application


Real-time force monitoring Robot set-up
Haptics investigations
Rehabilitation research

Technical data
Designation
Calibration
Resolution
Mass
Range of measurement, Fx, Fy
Range of measurement, Fz
Range of measurement, Mx, My
Range of measurement, Mz
Resolution, Fx, Fy
Resolution, Fz
Resolution, Mx, My
Resolution, Mz
Overload, Fxy
Overload, Fz
Overload, Txy
Overload, Tz
Rigidity, force XY axis (KFx, KFy)
Rigidity, Z axis (KFz)
Rigidity, force XY axis (KMx, KMy)
Rigidity, Z axis (KMz)
Resonance, frequency Fx, Fy, Mz
Resonance, frequency Fz, Mx, My

428

[g]
[N]
[N]
[Nm]
[Nm]
[N]
[N]
[N]
[Nm]
[N]
[N]
[Nm]
[Nm]
[N/m]
[N/m]
[Nm/rad]
[Nm/rad]
[KHz]
[KHz]

FTS-Delta
SI-165-15
Stand alone
913
165
495
15
15
1/16
1/8
1/264
1/264
3500
11900
230
420
37 x 106
61 x 106
52 x 103
94 x 103
1.5
1.7

FTD-Delta
SI-165-15
DAQ
913
165
495
15
15
1/128
1/64
1/2112
1/2112
3500
11900
230
420
37 x 106
61 x 106
52 x 103
94 x 103
1.5
1.7

www.schunk.com

FTS-Delta
SI-330-30
Stand alone
913
330
990
30
30
1/8
1/4
3/400
3/400
3500
11900
230
420
37 x 106
61 x 106
52 x 103
94 x 103
1.5
1.7

FTD-Delta
SI-330-30
DAQ
913
330
990
30
30
1/64
1/32
3/3200
3/3200
3500
11900
230
420
37 x 106
61 x 106
52 x 103
94 x 103
1.5
1.7

FTS-Delta
SI-660-60
Stand alone
913
660
1980
60
60
1/4
1/2
3/200
3/200
3500
11900
230
420
37 x 106
61 x 106
52 x 103
94 x 103
1.5
1.7

FTD-Delta
SI-660-60
DAQ
913
660
1980
60
60
1/32
1/16
1/1600
1/1600
3500
11900
230
420
37 x 106
61 x 106
52 x 103
94 x 103
1.5
1.7

FT-Delta
Measuring Force Sensors Rigid

Main views

 Bolt pitch circle

www.schunk.com

429

You might also like