Monitor The Construction Status of Piping Interface

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Measuring the Piping Progress

Dia Inch unit of Measure is used to measure the


progress of the Piping.
The weld joint of the pipe size is converted to the
equivalent Dia Inch of welding

Examples:
1. One welding joint of 8 inch diameter pipe = 8 Dia Inch
2. Two welding joints of 12 inch diameter pipe = 24 Dia Inch

Measuring the Piping Progress

Welding Control System- WCS

UO1 Contractor (GS) using WCS to monitor the dia


inch of all piping works at Shop as well as field.
WCS shall be updated on daily basis by contractor.
Status of individual line by service, area etc., shall be
checked in WCS database and it shall be saved in excel
sheet. Below table (excel) is extracted from WCS.
Total Dia-Inch Welded Dia

Ratio

Shop Total Shop Welded Field Total


Dia-inch
Dia-Inch
Dia-Inch

Field Welded
Dia-Inch

Area

Service

UGC340

OWS

2272

848

37.3

650

550

1622

298

N200

UA

5313.5

2420

45.5

822.75

734

4490.75

1686

N100

LS

11220

4276.25

38.1

5543.25

4266.25

5676.75

10

N200

EL1

2668

1509

56.6

586

561

2082

948

N200

HS

20463.5

7717

37.7

7615

6811

12848.5

906

N100

FG

2943

1113

37.8

1029

981

1914

132

N100

1239

444

35.8

396

348

843

96

S330

LC

551.25

551.25

Total Piping (AG/UG) Construction


Status
DESCRIPTION

TOTAL DIA-INCH

THIS WEEKLY

THIS MONTH

JOINTS

DIA-INCH

JOINTS

DIA-INCH

TOTAL JOINTS
DONE

TOTAL WELDED
DIA-ICH

BALANCE DIAINCH

PROGRESS (%)

SHOP

23,057.50

4.00

1,410

17,931.00

5,126.50

77.77%

FIELD

108,889.00

109

1,348

452

4,875.00

3,848

56,049.50

52,839.50

51.47%

131,946.50

109

1,348.00

454

4,879.00

5,258

73,980.50

57,966.00

56.07%

SHOP

115,136.00

109

1,215

617

6,651.00

7,915

78,622.00

36,514.00

68.29%

FIELD

299,991.00

270

2,519

1,214

10,382.00

6,934

58,224.00

241,767.00

19.41%

Sub-TOTAL

415,127.00

379

3,734.00

1,831

17,033.00

14,849

136,846.00

278,281.00

32.96%

SHOP

51,641.00

67

375

353

1,255.00

5,039

35,098.50

16,542.50

67.97%

FIELD

136,284.00

218

1,012

776

4,220.00

6,213

41,900.00

94,384.00

30.74%

Sub-TOTAL

187,925.00

285

1,387.00

1,129

5,475.00

11,252

76,998.50

110,926.50

40.97%

SHOP

60,881.00

14

154

253

1,310.75

2,305

16,358.00

44,523.00

26.87%

FIELD

103,656.00

15

57

90

770.00

466

4,046.00

99,610.00

3.90%

Sub-TOTAL

164,537.00

29

210.75

343

2,080.75

2,771

20,404.00

144,133.00

12.40%

A/G TOTAL

767,589.00

693

5,331.75

3,303.00

24,588.75

28,872.00

234,248.50

533,340.50

30.52%

GRAND TOTAL

899,535.50

802

6,679.75

3,757

29,467.75

34,130

308,229.00

591,306.50

34.27%

UG PIPING WORK
(RAYMOND)
U/G TOTAL
SMP-4 PIPING WORK
(DAEAH)

SMP-5 PIPING WORK (GS


DIRECT)

SMP-6 PIPING WORK


(AL-GHAMDI)

Interface Test Package - ITP


Each Interface Test Package (ITP) between Contractors
will be identified by unique ITP number. Only one unique
ITP will be assigned for verification of related activity to
close interface point. The minimum document to close
interface point shall be included in ITP. In some case, one
ITP can cover multi-ful IPs.

Interface Test Package - ITP


Issued Interface PKG numbers shall not be reused or reassigned. IPs shall be numbered according to the following
format.

Interface Test Package - ITP


The IP package including inspection reports approved by
Company required from Contractor A&B is as follows,

Monitor The Construction Status


of Piping.

WCS status
Total Piping Construction status
Interface Test Package (ITP) status

All the above status must be known before proceeding


with hydrotest/pneumatic of piping. Same time Company
can check, whether contractor can meet the IP testing
schedule or not.
All the above information's shall be provided by
Contractor to Company on weekly/daily basis.