SPECIFICATION FOR PRESSURE VESSEL PLATES,

CARBON STEEL,
LOW- AND INTERMEDIATE-TENSILE STRENGTH
SA-285/SA-285M
(Identical with ASTM Specification A 285/A 285M-90)

1.

Scope

the other. Combining values from the two systems may


result in nonconformance with the specification.

1.1 This specification covers carbon steel plates of


low- and intermediate-tensile strengths which may be
made by killed, semi-killed, capped, or rimmed steel
practices at the producers option. These plates are
intended for fusion-welded pressure vessels.

2.

2.1 ASTM Standard:


A 20/A 20M Specification for General Requirements for
Steel Plates for Pressure Vessels

1.2 Plates under this specification are available in


three grades having different strength levels as follows:

98

Grade

Tensile Strength,
ksi (MPa)

A
B
C

4565 (310450)
5070 (345485)
5575 (380515)

Applicable Document

3.

General Requirements and Ordering


Information

3.1 Material supplied to this material specification


shall conform to Specification A 20/A 20M. These
requirements outline the testing and retesting methods
and procedures, permissible variations in dimensions
and mass, quality and repair of defects, marking, loading, etc.

1.3 The maximum thickness of plates under this


specification, for reasons of internal soundness, is limited to a maximum thickness of 2 in. (50 mm) for all
grades.
NOTEFor killed carbon steels only refer to the following ASTM
specifications:

3.2 Specification A 20/A 20M also establishes the


rules for the ordering information that should be complied with when purchasing material to this specification.

A 299, Pressure Vessel Plates, Carbon Steel, ManganeseSilicon


A 515 Pressure Vessel Plates, Carbon Steel, for Intermediate and Higher Temperature Service
A 516 Pressure Vessel Plates, Carbon Steel, for Moderate
and Lower Temperature Service

3.3 In addition to the basic requirements of this


specification, certain supplementary requirements are
available when additional control testing or examination
is required to meet end use requirements. The purchaser
is referred to the listed supplementary requirements in
this specification and to the detailed requirements in
Specification A 20/A 20M.

1.4 The values stated in either inch-pound units or


SI units are to be regarded separately as standard.
Within the text, the SI units are shown in brackets. The
values stated in each system are not exact equivalents;
therefore, each system must be used independently of

3.4 If the requirements of this specification are in


conflict with the requirements of Specification A 20/
451

98

SA-285/SA-285M

1998 SECTION II

A 20M, the requirements of this specification shall


prevail.

5.

Chemical Requirements

5.1 The steel shall conform to the requirements as


to chemical composition shown in Table 1.

6.

Mechanical Requirements
6.1 Tension Tests:

4.

Heat Treatment

6.1.1 Requirements:

4.1 Plates are normally supplied in the as-rolled


condition. The plates may be ordered normalized or
stress relieved, or both.

6.1.1.1 The material as represented by the tension-test specimens shall conform to the requirements
shown in Table 2.

TABLE 1
CHEMICAL REQUIREMENTS

98

Composition, %
Elements
max A

Carbon,
Manganese, max
Heat analysis
Product analysis
Phosphorus, max A
Sulfur, max A
A

Grade A

Grade B

Grade C

0.17

0.22

0.28

0.90
0.98
0.035
0.035

0.90
0.98
0.035
0.035

0.90
0.98
0.035
0.035

Applied to both heat and product analysis.

TABLE 2
TENSILE REQUIREMENTS
Grade A

Tensile strength
Yield strength, min A
Elongation in 8 in. or [200 mm], min, % B
Elongation in 2 in. or [50 mm], min, %
A
B

Grade B

ksi

[MPa]

ksi

4565
24

[310450]
[165]
27
30

5070
27

Determined by either the 0.2% offset method or the 0.5% extension-under-load method.
See Specification A 20/A 20M.

452

[MPa]
[345485]
[185]
25
28

Grade C
ksi

[MPa]

5575
30

[380515]
[205]
23
27

98

PART A FERROUS MATERIAL SPECIFICATIONS

SUPPLEMENTARY REQUIREMENTS
Supplementary requirements shall not apply unless specified in the order.
A list of standardized supplementary requirements for use at the option of the
purchaser are included in Specification A 20/A 20M. Those which are considered
suitable for use with this specification are listed below by title.

98

S3.

Simulated Post-Weld Heat Treatment of


Mechanical Test Coupons.

S4.1 Additional Tension Test.


S14. Bend Test.

ADDITIONAL SUPPLEMENTARY REQUIREMENTS


Also listed below are additional optional supplementary requirements suitable for
this specification.
98

S57. Copper-Bearing
S57.1 The copper content, by heat analysis shall be
0.200.35% and by product analysis 0.180.37%.

98

S58. Restricted Copper


S58.1 The maximum incidental copper content by
heat analysis shall not exceed 0.25%.

453