Hitachi Chiller
Hitachi Chiller
Hitachi Chiller
SCREW TYPE
HITACHI
Nominal Capacity Range
R407C: 181kW to 1,089kW
156,000kcal/h
52 RT
R22:
191kW
164,230kcal/h
54RT
to
to
to
to
to
936,100kcal/h
310 RT
1,146kW
985,400kcal/h
336 RT
Technical Catalog I
Design Information
Model:
R22
RCU75AHYZ1
RCU100AHYZ1
RCU120AHYZ1
RCU150AHYZ1
RCU180AHYZ1
RCU200AHYZ1
RCU240AHYZ1
RCU270AHYZ1
RCU300AHYZ1
RCU330AHYZ1
RCU350AHYZ1
RCU360AHYZ1
RCU380AHYZ1
RCU400AHYZ1
R407C
RCUG75AHYZ1
RCUG100AHYZ1
RCUG120AHYZ1
RCUG150AHYZ1
RCUG180AHYZ1
RCUG200AHYZ1
RCUG240AHYZ1
RCUG270AHYZ1
RCUG300AHYZ1
RCUG330AHYZ1
RCUG350AHYZ1
RCUG360AHYZ1
RCUG380AHYZ1
RCUG400AHYZ1
New SeriesHITACHI H Series air-cooled water chillers which achieve to 400HP, are designed for all
the conveniences of chilled water air-conditioning systems and modern manufacturing industriesthese
chillers can operate normally even at 43 of the outdoor air temperaturethat is why the chillers can apply
for larger temperature range
HITACHI air-cooled water chillers are equipped with newly-developed HITACHI A type semi-hermetic
screw compressors which features are lower noise and vibration, reliable long period operation and used the
higher performance air-cooled condenser that result in compact structure
The units are composed of a compressor(s), a air-cooled condenser(s), a shell-tube type evaporator and
auxiliary and control equipment, these parts are equipped in the metal cabinet for avoiding the climate
influencethe shell plate is used the galvanize steel with oleoresin paint
FEATURE
Adopting new screw rotor outline , HITACHI have developed the higher performance screw type compressor
to improve the operation reliable and durable.
In this new century, people pay more attention to the change of the environment
HITACHI semi-hermetic screw type compressor ,which use the R407C directly, reduce the
refrigerant leak greatly, and have been sold 140,000 in the world !
Discharge Outlet
Slide Valve
Suction Inlet
Bearing
Highly
Efficiency Operation
To combine highly performance fins in the air side heat exchangerefficiently screw type compressor and water
side heat exchanger together properly can achieve high efficiency operation.
Heat-Exchanger(AHYZ1)
Air
side
heat-exchanger
used
the
distribute
equally
highly
Improve the air heat exchanger configure. Adopt highly efficiency inner thread tube 3Improve Air velocity distribution to enhance efficiency and defrost performance
Smaller
Due to the combination of the HITACHI semi-hermetic screw compressors and smooth-air-flow propeller fans for
air side heat exchangers, smaller vibration and lower sound operation has been achieved, Therefore, in most
cases, special vibration absorbing curbs are not required by utilizing factory-supplied rubber mats.
FEATURE
Capacity Control
Continuous Capacity Control
Chilled water outlet temperature can be controlled precisely within 0.5 of the setting
temperature. This control is performed by applying a micro-computer to the continuous
capacity control type screw compressor.
This precise temperature control is not only suitable for air conditioning, but also for industrial
Load-up signal
When there is a big
use.
12sec.
difference between
set temperature and
actual temperature
60sec.
Load-up signal
Start
2sec.
Inlet water
temperature
60sec.
Outlet water
temperature
Outlet water
temperature
Inlet water
temperature
Neutral zone
standard
6
4
(Set temperature:5)
Stop
Stop temperature
standard
Lapsed time
Load-down signal
A given load status is
maintained.
2sec.
60sec.
-Principle of Continuous Capacity ControlContinuous capacity control is performed by adjusting the slide valve position as shown below.
The slide position can be changed freely between 100% and 15% in accordance with cooling load.
Load-up
Load-down
Hold
Other Option
The following specifications are available on order basis.
Please contact local Hitachis distributors if required.
G/W communication adapter or RS485 physics
connector.
High static pressure fan (Outside static pressure:150Pa)
Remote control box
Liquid crystal touch panel with big screen
HITACHI water chillers group control system
GENERAL DATA
Nominal Cooling
Capacity *1
R22
Nominal Cooling
Capacity *1
R407C
RCU120AHY Z1
RCU150AHY Z1
RCU180AHY Z1
RCU200AHY Z1
RCU240AHY Z1
RCUG120AHY Z1
RCUG150AHY Z1
RCUG180AHY Z1
RCUG200AHY Z1
RCUG240AHY Z1
kW
191
286
358
382
537
573
716
kcal/h
164,230
245,916
307,825
328,461
461,737
492,691
615,649
203.6
RT
54.3
81.3
101.8
108.6
152.7
163.0
kW
181
272
340
363
510
544
680
kcal/h
156,019
233,620
292,433
312,038
438,650
468,057
584866.7
RT
51.6
77.3
96.7
103.2
145.1
154.8
193.4
100150
mm
2,390
4,490
4,490
4,490
6,590
6,590
9,080(Minimum)
Depth
mm
1,940
1,940
1,940
1,940
1,940
1,940
1,940
Height
mm
2,170
2,170
2,170
2,170
2,170
2,170
2,170
kg
2,057
3,822
4,017
4,103
5,688
5,827
24,017
10015(5)*20
10015(7.5)*2,0
Standard
R22
R407C
R407C
Flow Control
Number of Circuit
Ty pe
Compressor
60ASCC-Z
Condenser
Air Discharge
Ev aporator
Semi-Hermetic Screw Ty pe
Model
10015(7.5)*20
Quantity
Condenser Fan
HeatExchanger
RCU100AHY Z1
RCUG100AHY Z1
Width
Net Weight
Ref rigerant
RCU75AHY Z1
RCUG75AHY Z1
Capacity Control
Outer
Dimension
R22
R407C
50ASCC-Z
60ASCC-Z
60ASCC-Z
60ASCC-Z
60ASCC-Z
3
60ASCC-Z
4
Cross Fin Ty pe
Direct driv e Propeller Fan
kW
1.1
1.1
1.1
1.1
1.1
1.1
1.1
12
12
28
m 3/min
930
1,860
1,860
1,860
2,790
2,790
3,720
Ov ercurrent Relay f or Compressor , Internal Thermostat f or Compressor, Rev erse Phase Protection Dev ice f or Compressor,Thermal Ov ercurrent
Relay f or Fan Motor,High Pressure Switch, Low Pressure Control, Suction Gas Temperature Control,Freeze Protection Thermistor control,Oil Heater,
Discharge Gas Thermistor, Fusible Plug, Fuse f or Control Circuit and Pressure Relief Valv e
With 90 Inner
Diameter
Companion Flange
Connection Hole
Main Power
(square orif ice)
mm
Circuit
mm
264.5102
52
2500200
500200
364.510252
464.510252
664.521022
52
kg
2,524
4,442
4,635
4,745
6,813
6,956
24,635
Width
mm
2,600
4,700
4,700
4,700
6,800
6,800
24,700
Depth
mm
2,190
2,190
2,190
2,190
2,190
2,190
2,190
Height
mm
2,510
2,510
2,510
2,510
2,510
2,510
2,510
Shipping Weight
Shipping
Dimension
*3
NOTE:
1. The nominal cooling capacities are based on GB/T
18430.1-2001(*1)
Chilled Water Inlet/Outlet Temperature12/7
Condensate Air Inlet Temperature35(DB)
2. Applicable Power Supply
Main Power SourceAC3 380V50HZ
Control Power SourceAC1220V50HZ
3.The units greater than 240AHYZ1 including 240AHYZ1
consist of two modules and are separately shipped.(*3).
4. Water Flow
1) RCU(G)240,300,360,400AHYZ1
It is necessary to control the same water quantity to each cooler.
2) RCU(G)270,330,350,380AHYZ1
The chilled water flow rate is different between No.1 & No.2 units. It
is necessary to control the water quantity of each unit with adjusting
valves(Filed-Supplied).
5. It is required to connect electrical control wires between No.1 and
No.2 units for the unit greater than 240AHYZ1including 240AHYZ1.
6. ( ) marked with *2 is available by selection switch.
Working Range
Standard
515
543
I t em
Chilled Water Outlet Temperature
Condenser Air Inlet Temperature(DB
GENERAL DATA
R22
R407C
RCU330AHYZ1
RCUG330AHYZ1
RCU350AHYZ1
RCU360AHYZ1
RCU380AHYZ1
RCU400AHYZ1
RCUG400AHYZ1
kW
740
764
919
955
1,074
1,110
1,146
kcal/h
636,285
656,922
790,198
821,152
923,474
954,428
985,383
325.9
RT
210.5
217.3
261.4
271.6
305.5
315.7
kW
703
726
873
907
1,020
1,055
1,089
kcal/h
604,471
624,076
750,688
780,095
877,300
906,707
936,113
RT
199.9
206.4
248.2
258.0
290.1
299.8
309.6
10015(7.5)*20
10015(6)*20
10015(7.5)*20
mm
9,080(Minimum)
9,080(Minimum)
11,180(Minimum)
Depth
mm
1,940
1,940
1,940
1,940
1,940
1,940
Height
mm
2,170
2,170
2,170
2,170
2,170
2,170
2,170
kg
4,103+4,017
24,103
5,688+4,103
5,827+4,103
25,688
5,827+5,688
25,827
Standard
R22
R407C
R407C
Flow Control
Number of Circuit
Type
Model
Quantity
Compressor
HeatExchanger
RCU300AHYZ1
RCUG300AHYZ1
Width
Net Weight
Refrigerant
RCU270AHYZ1
RCUG270AHYZ1
Capacity Control
Outer
Dimension
R22
R407C
Condenser
Condenser
Fan
Power Input
Fan Motor
Quantity
Air Discharge
13,280(Minimum)
1,940
5
Semi-Hermetic Screw Type
60ASCC-Z
60ASCC-Z
60ASCC-Z
60ASCC-Z
60ASCC-Z
60ASCC-Z
60ASCC-Z
kW
1.1
1.1
1.1
1.1
1.1
1.1
1.1
8+8
28
12+8
12+8
212
12+12
212
m3/min
3,720
3,720
4,650
4,650
5,580
5,580
5,580
Safety Devices
Overcurrent Relay for Compressor , Internal Thermostat for Compressor, Reverse Phase Protection Device for Compressor,Thermal
Overcurrent Relay for Fan Motor,High Pressure Switch, Low Pressure Control, Suction Gas Temperature Control,Freeze Protection Thermistor
control,Oil Heater, Discharge Gas Thermistor, Fusible Plug, Fuse for Control Circuit and Pressure Relief Valve
Main Power
(square orifice)
mm
2500200
Circuit
mm
Evaporator
Connection Hole
Shipping Weight*3
Shipping
Dimension
2102
252
664.5
764.52102252
864.52102252
kg
4,745+4,635
24,745
6,813+4,745
6,956+4,745
26,813
6,956+6,813
26,956
Width
mm
24,700
24,700
6,800+4,700
6,800+4,700
26,800
26,800
26,800
Depth
Height
mm
mm
2,190
2,510
2,190
2,510
2,190
2,510
2,190
2,510
2,190
2,510
2,190
2,510
2190
2,510
NOTE:
1. The nominal cooling capacities are based on GB/T
18430.1-2001(*1)
Chilled Water Inlet/Outlet Temperature12/7
Condensate Air Inlet Temperature35(DB)
2. Applicable Power Supply
Main Power SourceAC3 380V50HZ
Control Power SourceAC1220V50HZ
3.The units greater than 240AHYZ1 including 240AHYZ1
consist of two modules and are separately
shipped.(*3).
The common chilled water piping (Filed-Supplied)
between each water cooler shall be directly connected
at site.
4. Water Flow
1) RCU(G)240,300,360,400AHYZ1
It is necessary to control the same water quantity to each cooler.
2) RCU(G)270,330,350,380AHYZ1
The chilled water flow rate is different between No.1 & No.2 units. It is
necessary to control the water quantity of each unit with adjusting
valves (Filed-Supplied) .
5. It is required to connect electrical control wires between No.1 and No.2
units for the unit greater than 240AHYZ1including 240AHYZ1.
6. ( ) marked with *2 is available by selection switch.
Working Range
Item
Chilled Water Outlet Temperature
Condenser Air Inlet Temperature(DB
3
Standard
515
543
DIMENSION DATA
Unit Dimensions
RCU(G)75AHYZ1
DIMENSION DATA
Unit Dimensions
RCU(G)180AHYZ1 and RCU(G)200AHYZ1
DIMENSION DATA
Unit Dimensions
RCU(G)330AHYZ1 and RCU(G)350AHYZ1