1367482635621-Vacuum Air Brake
1367482635621-Vacuum Air Brake
1367482635621-Vacuum Air Brake
Introduction
Diesel locomotives of Indian Railways are equipped with brake system designed by
either M/S WABCO/ USA or M/S KNORR Germany or IRAB-1 Indian Railways or M/S
KNORR Brake (NYAB). Initially locomotives were equipped with M/S WABCO, USA
designed 28LV-1 Brake system for use in vacuum brake train only. In 80's locomotives
were switched over to 28LAV-1 Brake system for use both in vacuum and air braked
Trains.
In 90's some of the locomotives were equipped with IRAB-1 brake system, which are
suitable for only air-braked trains.
Recently acquired WDG4 and WDP4 locomotives are equipped with CCB (computer
control brake) system designed by KNORR BRIMSE (NYAB), which are suitable for air
braked train only.
1.
2.
3.
4.
5.
6.
Safety devices
7.
1.Locomotive brakes may be applied with any desired pressure between the minimum and
maximum. This pressure will be maintained automatically in the locomotive brake cylinders
against normal leakage from them.
2. The locomotive brakes can be graduated on & off with either the automatic or the independent
brake valve.
3. It is always possible to release the locomotive brakes with the independent brake valve, even
when automatically applied.
4. The maximum braking position emergency, ensuring the shortest possible stops distance.
6. Automatic brake application and power cut off with idle rpm of engine is always possible
during train parting.
Introduction
Loco brake system is provided to stop the Locomotive, whenever it runs as light
engine. It is purely compressed air brake system known as independent brake system. For
this separate air circuit is provided in 28LAV-1 & IRAB-1 Brake system which is
independent to other air circuit. SA9 Independent brake valve is provided in driving
control stand for application & release of loco brake. Valve has three positions ie. quick
release, release and application.
Purpose of this system
Independent Brake System is designed to apply and release brake on locomotive.
When locomotive is moving itself Independent Brake is applied.
Loco brake valves
System consists SA9 Independent Brake valve, Double check valve and C2-Relay
valve.
Description of loco brake (Independent brake) system
The SA9 Valve handle is kept normally in release position (right side). MR air is
always available at port no.30 of SA9 valve. When handle is brought in application
potion (left side) than SA9 port 30 connects port 20 and starts supplying pilot air to C2Relay air valve. The pilot air passes through MU2B Valve port no. 2&20 and inters to
C2-Relay at port no.2. See the line diagram of loco brake system. The pilot air pressure
depends upon the handle position, at maximum it is 3.5kg/cm2. The C2-relay air valve
actuates after getting pilot air and connects MR pressure to brake cylinders of
locomotive through port no.1&3. The brake cylinder pressure depends upon pilot air
pressure, supplied into C2-Relay chamber through port no.2. For full brake application
SA9 handle is moved to maximum travel position. In this way independent brake/loco
brake is applied. There is a gauge line taken from front truck of locomotive to drivers
cabin control stand for indicating brake cylinder pressure. When SA9 handle is placed in
release position, loco brakes are released. How MR air is reduced to 3.5kg/cm2 see
internal function of the SA9 valve & C2-Relay valve.
SA9 Brake valve handle is normally kept in release position. Loco brake can be applied
through SA9 Valve handle. It can be applied any desired pressure between the minimum
and maximum. This pressure will be automatically maintained in the locomotive brake
cylinders against normal leakage from them. The locomotive brake can be graduated on
and off with either the automatic (A9) or the independent brake valves (SA9). It is always
possible to release the locomotive brakes with the SA9 valve.
Introduction
Indian Railway runs both the trains vacuum and air brake. In vacuum brake train
brakes are controlled through vacuum of train pipe. After coupling the locomotive to the
vacuum brake train the vacuum is obtained in train pipe. An exhauster unit is provided to
create the vacuum in the train pipe as well as the Vacuum cylinders of each coach/wagon.
A9 automatic brake valve is provided in driving control stand through which vacuum is
controlled. Normally valve handle is kept in release position.
Purpose of this system
This system is designed to apply and release brakes on vacuum brake train. Which is
achieved through A9 Automatic Brake valve.
Vacuum brake system valves
System consists A9 Automatic Brake valve, VA1B Control valve and HS4 Control
valve.
Description of Vacuum Brake system
Locomotive and train has a long vacuum brake pipe, in which 56cm vac. is
maintained through an exhauster unit. There is a VA1B control valve in between train
pipe and exhauster unit, which controls 56cm vac.in train pipe. A9 automatic brake valve
is provided in driving control stand to apply vacuum brake on train. When A9 handle is
placed in application zone, train pipe vacuum drops and brakes are applied through
vacuum cylinders of coaches.
The function of A9valve is to supply control pressure to Add.C2-Relay valve. The
function of VA1Bcontrol valve is to maintain 56cm vac. in train pipe. The function of
HS4 valve is to supply 1.7kg/cm2-air pressure to bottom chamber of VA1B control valve
at port no.1. Other valves are provided in this circuit for MU operation. See line diagram
of vacuum brake circuit.
Charging of system
Air at 8 to 10kg/cm2 pressure is charged at different valves through MR-2. See the
line diagram of vacuum system. Port no.30 of A9 valve, port no.1 of Add.C2-Relay valve
and port no.1 of HS4 control pressure valve. A9 valve handle is kept at release position
normally. Simultaneously A9valve will supply control pressure to Add. C2-Relay valve,
through MU2B valve. After getting supply of control pressure, Add.c2-relay valve will
supply 5kg/cm2 pressure to BP pipe. BP pipe is connected to VA1B control valve top
chamber at port no.3. At port no.1 control pressure at 1.7kg/cm2 is supplied through HS4
control valve. VA1-B control valve maintains 56cm vacuum in train pipe.
Application of brake
A9 handle is moved in application zone for brake application. A9 reduces Control
pressure to Add.C2 Relay valve. Add. C2 Relay reduces BP pressure in proportion to
control pressure dropage. BP pressure may be zero if A9handle moved at over reduction
position. If handle is placed at emergency position BP will drop to zero immediately
within 3 sec. After dropping BP pressure brakes are applied.
Releasing of brake
When handle is moved to release position, A9 valve starts supplying full control pressure
to Add. C2 Relay valve causing BP pressure start increasing to 5kg/cm2 and brakes are
released.
BLOCKAGE TEST: Remove one end of the vacuum hose pipe and raise it upwards.
If more than 8cm vacuum is created, there is a blockage in the system.
2.
3.
LEAKAGE TEST: Vacuum on dummy and on leak disc should be not vary by more
than 3 cm.
The Board has therefore standarised the vacuum level in engine and brake van for all
Railways both the traction.
Type of service
Engine
Brake van
Average
53
47
50
Passenger
50
44
47
Goods
46
38
42
M/E
Introduction
BP system is introduced to run Air Brake train, where train brake is controlled
through BP pipe instead of vacuum pipe. Additional C2-Relay valve is introduced in this
system to supply sufficient air to BP system.
BP system valves
BP system consists A9 Automatic brake valve, MU2B valve, Add./C2-Relay
valve, Air flow measuring valve,R-6 Relay air valve and Air flow indicator.
Purpose of this system
This system is introduced to run air brake train. Air Brake system can sustain better
brake power and can haul a long train.
Description of BP system
MR air is connected to A9valve at port 30 and Add./C2-Relay valve at port 1. Normally
A9 handle is kept at release position and maintains 5kg/cm2-air pressure in brake pipe. In
this position brakes are found released position. When A9handle is moved to application
zone, B P pressure drops through Add. C2-Relay valve, port 3 is connected to exhaust. In
this condition brakes are applied.
Brake release
When A9 handle is moved to release position, Add. C2-Relay valve port3 is connected
to port1 and B P pipe is charged to 5kg/ cm2 and brakes are released.
10
regulating valve diaphragm assembly moves down ward and allow the inlet valve spring
to seat the double ball check assembly at the inlet valve seat. The A-9 Automatic Valve
resumes a lap position.
Application
When the brake valve handle is moved into the minimum reduction, service
application zone or full service position, the regulating cam dog 3 on the brake valve
handle shaft 32 will permit the inlet valve assembly to move away from the exhaust port
by the exhaust valve spring 7. The inlet valve assembly will carry the double ball check
assembly with it. This movement will unseat the double ball check valve at exhaust valve
seat, thus allowing brake pipe air to flow to exhaust. With the reduction of pressure on
regulating valve diaphragm 9, the regulating valve spring 12 will cause a movement of
the diaphragm assembly toward the inlet valve and the double ball check valve assembly
will be seated at the exhaust valve seat again. The brake valve to assume a lap position.
Pressure drop in
Minimum reduction.5/.7kg/cm2
Full service-------------1.7/2kg/cm2
Over-reduction--------2.5kg/cm2
Release after application
Movement of the brake valve handle toward release position will cause regulating cam 3
to move the inlet valve assembly toward the regulating valve diaphragm assembly. This
movement will cause the double ball check valve 5 to be unseated at the inlet valve. Main
reservoir air will then flow through the inlet valve to port No. 5. The supply of main
reservoir air to the face of regulating valve diaphragm 9 will increase and move down
word, resulting in the compression of the regulating valve spring 12. When the force have
equalized across the regulating valve diaphragm 9, the double ball check assembly 5 will
again seat at the inlet valve due to the force of the inlet valve spring and the brake valve
will assume a lap position. Thus it can be seen that the brakes can be graduated off in
proportion to the brake valve handle movement from an application position toward
release position.
Emergency position
When the brake valve handle is moved to emergency position, the brake valve
will perform all the service operations. In the emergency position, the emergency cam
dog 23 is actuated through special cam dog 23 to open vent valve 19 and allow brake
pipe air to be vented at an emergency rate. Release after an emergency is the same as
previously described under release after service.
11
12
Vacuum pressure in the vacuum brake pipe is supplied through port No. 1 in the
pipe bracket to the spring chamber of the quick release valve where it is blanked.
Vacuum reservoir pressure coming from the control valve is supplied through port No. 7
in the pipe bracket and is also blanked to the position of release valve 17.
Application
When the brake valve handle is moved in to the application zone, the regulating
cam dog 3 on the brake valve handle shaft 24 forces the inlet valve assembly towards the
regulating valve diaphragm assembly and causes the double ball check valve to seat at the
exhaust port and open at the inlet valve, thus supplying main reservoir air through the
open inlet valve in to the independent application and release pipe(Port 20) which will
pilot the locomotive brake application. Main reservoir air is also ported through a choke
passage to the face of the regulating valve diaphragm 9.
When the pressure on the
face of the regulating valve diaphragm 9 overcomes the force exerted by the regulating
valve spring 12, the regulating valve diaphragm assembly will move down word. This
will allow the inlet valve spring to move the double ball check assembly to the inlet valve
seat, thus the brake valve will assume a lap position.
Release after application
When the independent brake valve handle is moved toward release position, the
regulating cam dog 3 allows to move the inlet valve assembly up word, carrying the
double ball check valve assembly with it, thus unseating the exhaust port while inlet
valve remaining seated at the inlet valve seat. A graduated release of brake cylinder
pressure will be there, in proportion to the movement of the brake valve handle. At the
same time, pressure will be released from top of the diaphragm. When the forces across
the regulating valve diaphragm 9 have equalized, the double ball check valve assembly
will be seated at both the inlet and exhaust valve seats, and thus the independent brake
valve will again assume a lap position.
Quick release position
The quick release position of the independent brake valve provides a means of
releasing an automatic brake application on the locomotive without affecting the
automatic brake application present on the train brakes.
When the independent brake valve handle is placed in the quick
release position, the release valve cam 19 positions the release spool valve 17 to connect
vacuum control reservoir port 7 to vacuum brake pipe port 1. Since the automatic brake
application is in effect on the train, the vacuum pressure in the vacuum control reservoir
will be greater than that of vacuum brake pipe, thus the vacuum control reservoir will be
permitted to equalize with the vacuum brake pipe. This will cause the proportionate brke
valve to assume a release position and subsequently cause the release of the brake
cylinder pressure on the locomotive. The equalizing of the vacuum control reservoir and
vacuum brake pipe will have no effect on the VA1B control valve, thus the vacuum
train brakes will remain applied.
13
14
1. Introduction
The Proportionate Brake valve is a vacuum operated, automatic, self-lapping,
pressure maintaining type valve designed to be controlled by vacuum pressure. It supplies
and exhausts brake cylinder air pressure on locomotive. The movement of the automatic
brake valve handle in application zone effects the brake cylinder air pressure.
2. Objective
The Proportionate Brake Valve senses the vacuum drop in vacuum train pipe and
applies proportionate brake on locomotive.
3. Construction
The Proportionate brake valve consists of a pipe bracket and a valve portion. The
valve portion contains two diaphragms large and small selected to provide for proper
reference of vacuum train pipe and loco brake cylinder pressure. Movement of the spool
valve controls the supply of air to pilot the brake cylinder pressure. During a brake
application, the spool valve and large diaphragm assembly moves up to open the
application check valve 3. The spool valve element also serves to exhaust at the bottom
of the brake valve, the air pressure controlling the supply to the brake cylinders. Port I is
connected to vacuum train pipe and the chamber A under the large diaphragm as w ell as
to the top chamber through a ball valve. Top chamber is connected to port 7 and vacuum
reservoir pipe. At release position ball valve is lifted connecting both the chambers to
train pipe for creating same vacuum. Thus, initially, the pressure in the vacuum control
reservoir and the vacuum train pipe is the same.
4. Operation
MR air pressure is supplied to the top of the application check valve3 through port
30. When the A9 brake valve handle is moved to service position, brake pipe pressure is
reduced. This pressure reduction affects the VA1-B control valve, which in turn,
functions to admit atmospheric air in to the vacuum train pipe. Atmospheric air flows to
port 1 of the proportionate brake valve where the vacuum in the chamber under the large
diaphragm is destroyed. The increase of pressure in this chamber acts upon the
diaphragm to move the spool valve stem up ward to open the application check valve 3.
When the application check valve 3 is opened, the MR air through limiting valve flows to
C2-Relay valve for piloting the loco brake cylinder pressure. Same air is ported through a
choke to the spring chamber above the small diaphragm of Prop/valve. When the air
pressure builds up and balances against force of the vacuum train pipe pressure on the
large diaphragm. When this balance is reached, the spool valve moves down and closes
the application check valve 3 at which time the spool valve will assume a lap position.
15
As the brake valve handle is moved towards release position, the brake pipe
pressure is increased, thus the VA1-B control valve functions to connect the vacuum train
pipe to the exhauster. In the train pipe vacuum is created as well as in the bottom
chamber of large diaphragm. The diaphragm follower will resume the previous position.
The brake cylinder pilot pressure will be exhausted through the service valve stem at port
10. The exhaust of brake cylinder pressure will be proportional to the brake pipe pressure.
With each movement of the brake valve handle towards release position, a proportionate
amount of brake cylinder pressure will be exhausted. Thus, it can be seen that when the
brake valve handle is moved from service position towards release position, a graduated
release of locomotive brakes take place.
The quick release of an automatic brake application on the locomotive is
achieved through quick release position of SA9 valve. The vacuum control reservoir
piped to port 7 is connected to the vacuum train pipe port 1. The equalization of pressures
across the large diaphragm will permit the spool valve assembly downward. Thus
causing the brake cylinder control air to flow through the spool valve and exhaust to
atmosphere at port 10.
16
17
18
MU 2B VALVE
1. Introduction
The MU- 2B valve is a two-position valve with a pipe bracket. It is used in
multiple unit service. The MU-2B valve pilots the F-1 selector valve. It is a device that
enables equipment of one locomotive to be controlled by equipment of another. It also
controls the movement of the VA1 release valve. The two positions used in the MU2B valve is "LEAD" and "TRAIL or DEAD."
2. Objective
This valve is provided to work in multiunit operation. In trail unit brake
application valves are isolated through this valve.
3. Construction
MU2B Valve has two positions, which works as a spool valve. It has number of
port connections.
4. Operation
In "LEAD" position, main reservoir air piped to port 63 is connected to port 53
and thus to the double check valve that leads to the piston of the VA1 release valve.
Independent brake control pressure is connected to port 2 &20 of the MU 2B valve. Port
13 and port 3 are connected as a means of providing the passage to charge the brake pipe
from the automatic brake valve. Port 30 connected to the F1 selector valve provides the
connection for a supply of MR air that positions the F1 selector valve when the
locomotive is used as a trailing unit.
When the unit is used as a trail locomotive, the MU-2B valve is positioned in
"TRAIL or DEAD" position. Ports 2, 3, and 20 are blanked at the MU-2B valve. Port 53
is connected to exhaust at the MU- 2B valve. Main reservoir piped to port 63 is
connected to port 30, which in turn, positions the F-1 selector valve of trail position
operation. At the F- 1 selector valve, brake cylinder equalizing pipe air, port 14, is
connected to ports 16 and 20, both of which are connected through a double check valve
and thus to the control port of the relay valve. This provides a passage for air emanating
from the lead unit during a brake application.
19
F1 SELECTOR VALVE
1. Introduction
The F-1 Selector valve performs the function of arranging the brake equipment on
the locomotive to lead or trail, other type of brake equipment. It performs the function of
protecting a trailing locomotive brake equipment by automatically resetting the brake
control to lead position in the event of a separation between locomotive units.
2. Objective
To apply loco brake on trailing locomotives during parting of multi unit locos. It
works as a safety valve.
3. Construction
The selector valve consists of three sections and a pipe bracket. The pipe bracket has
number of port connections. Port 15 controls the protection portion. The transfer sections
are controlled by pressure in pipes Nos. 53 and 63. Connections are made as shown in the
positioning chart for the positions "Lead", "Trail or Dead". There are three-spool valve
no.6, 9 & 12. Which changes the port connections during trail and loco parting.
2. Operation
Operation of the selector valve is under control of the MU2B valve.
Lead position
When the 28LAV-1 equipped locomotive is the lead unit, air pressure to ports 53
and 63 of the selector valve is vented and connections made as shown in lead position of
the position diagrammatic. Control valve pressure flows from port 4 to 16 and from there
through a double check valve to the C-2 Relay valve. Pressure from the brake cylinder
line flows from port 30 to 14, hence to the brake cylinder-equalizing pipe of the lead
locomotive. The brake cylinder-equalizing pipe is used to control brakes on trailing units.
Trail position
When the 28LAV-1 equipped locomotive is the trailing unit or the dead unit,
operation of the selector valve is achieved by supplying MR pressure to port 53 of the
selector valve, causing the selector valve to assume the position as shown in the position
diagrammatic under "Trail or Dead". Under this condition, air pressure from the brake
cylinder equalizing pipe enters port 14 and flows to ports 16 and 20 and thus to the C-2
Relay Valve of the trailing or dead locomotive. Thus, automatic and independent brake
applications initiated at the lead -locomotive are transmitted to the trailing or dead
28LAV1quipped locomotive and result in the same brake cylinder pressures as on the
lead locomotive.
20
1. Introduction
The VA1B Control valve controls the vacuum of train pipe. It connects the train
pipe to atmosphere or exhauster as per variation in BP pressure. It is a very sensitive
valve, which works on two deferent pressure 5kg/cm2 and 1.7 kg/cm2. It helps to operate
the train vacuum brakes. This valve also acts as a pilot to operate the locomotive air
brake through proportionate brake valve.
2. Objective
VA1B control valve is deployed in vacuum brake system to apply and release the
train brake.
3. Construction
The control valve has three portions. Top cover, valve body and bottom cover
with protection valve. The valve body contains sleeve, control valve 6, contacted on its
upper side through its upper pusher pin 7 to small diaphragm 8 through diaphragm
follower 9. It is also contacted on its bottom side through lower pusher pin 19 to large
diaphragm 21 through diaphragm follower 22. The VA1B Control valve has six pipe
connections (see piping diagram).
3 Brake Pipe pressure
6 Vacuum train pipe
2 --Vacuum train pipe
1 Vacuum Control pipe
7 Vacuum Reservoir Pipe to exhauster
8 Atmosphere through GD-80 filter
Top diaphragm makes two chambers, chamber A is connected to B P pressure
5kg/cm2 through port 3 and chamber B is connected to atmosphere through a breather
port. Bottom diaphragm makes two chambers, chamber C is connected to vacuum train
pipe through port2 and chamber D is connected to vacuum control pressure 1.7kg/cm2
through port1.
3. Operation
The VA1B control valve is actuated through A9 valve. The deferent positions of
A9 is described below.
21
Release
When 5kg/cm2 pressure is available in chamber A, 56cm vacuum in chamber C,
and 1.7kg/cm2 pressure in chamber D, the valve remains in balanced or lapped position
and all the ports are closed.
Suppose there has been a brake application, in chamber A pressure will drop and
in chamber C vacuum will drop. When the A9 valve handle is moved in release position
the brake pipe pressure starts increasing, the pressure in chamber A also increases, the
control valve moves down connecting port 7 to port 6. In this way the exhauster starts
creating vacuum in the train pipe. As the vacuum is restored in the vacuum train pipe and
in chamber C of the control valve, the 1.7kg/cm2 pressure supplied to chamber D moves
the diaphragm 20 and valve 6 upward. When the vacuum in chamber C is increased to
approximately 56cm the upward movement of the valve 6 will lap itself leaving only
enough opening to permit the exhauster to maintain vacuum against leakage in the train
pipe.
Application
When the vacuum is restored in the vacuum brake system and it is desired to
apply the brakes, the brake valve handle is moved to application position, causing a
reduction in brake pipe pressure.
As chamber A of the VA1B Control Valve is connected to the brake pipe, a
reduction in pressure in this chamber also takes place. The 1.7kg/cm2 pressure in
chamber D then moves the diaphragm follower and control valve upward as the brake
pipe pressure is reduced. The control valve connects pipe 6 and chamber C to
atmospheric port 8. Thus, atmospheric air pressure enters the vacuum train pipe. Thereby
the vacuum brakes are applied on train. The pipe connection no. 2 between chamber C
and pipe 6 allows drop in vacuum in chamber C through a choke also and the valve
comes to lap position. The constant braking force is maintained against normal leakage. It
is understood that two pressure i.e. brake pipe and vacuum are varying and for different
combination of these two forces the valve gets lapped position giving different braking
forces.
Emergency
When it is desired to make the shortest possible stop, the brake valve handle is
moved to Emergency position, causing an emergency rate of brake pipe reduction.
22
The HS4 control air valve also contains provision for reducing any excess
pressure in the delivery pipe, as when the pressure called for by the setting of adjusting
handle 15 is lowered. Excess pressure in the chamber above diaphragm 11 moves the
diaphragm and exhaust valve seat 10 downward away from exhaust valve 5b, The excess
air pressure then flows past the unseated exhaust valve 5b, through the exhaust valve
spring chamber and the diaphragm spring chamber and out to atmosphere through the
opening in the bottom cover.
23
1. Introduction
The air flow measuring valve is suitable for use on locomotives that are equipped
to operate trains fitted with 28LAV1 brake system and is designed for fitting in the main
air supply pipe.
2. Objective
This valve indicates the leakage of BP pipe through an indicator in term of
wagon. Indicator is provided on driving control stand so that Driver can watch easily.
3. Construction
The AFM valve has two main connections, one is connected to main air supply
and other to the Additional C2-Relay valve. Choke A is provided to supply MR air to top
of disc valve. Disc valve has two small ports, one connects to MR air and other connects
to Additional C2 Relay valve. Disc valve is pressed down through a follower & spring on
its seat. Choke B is provided in between top chamber of main valve and MR supply line.
Choke C is provided to supply `main diaphragm top chamber air to indicator, when
diaphragm moves down word. Choke D is provided for calibrating the valve.
4. Operation
When the brake pipe is fully charged with air and the air brake is in the release
condition, the air flowing from the main air supply through the Air flow measuring
valve and to the brake pipe is that necessary to overcome leakage. In this condition the
check valve is closed as shown in diagram and air from the main supply passes through
choke A in to the space under the check valve follower and out to the Additional C2Relay valve. It also passes in to the chamber under the diaphragm via the space around
the follower. At the same time, air from the main supply passes through a filter and
choke B in to the chamber above the diaphragm.
So long as the pressures above and below the diaphragm are equal, the diaphragm
floats against the choke C. As brake pipe leakage occurs, the pressure at the outlet port
and under the diaphragm falls and the diaphragm is moved down away from the choke C
by the pressure above it. This permits air entering the chamber above the diaphragm via
choke B, to flow through choke C to an indicator and through choke D to atmosphere.
Choke D is smaller than choke C and an intermediate pressure builds up in the
passage between them and registers on the indicator. This intermediate pressure is
related to the flow of air through choke C that is controlled by the diaphragm reacting to
the pressure under it. As the pressure under the diaphragm and at the outlet port relative
24
to the main supply pressure, also determines the flow of air through choke A, it follows
that the intermediate pressure is related to this flow of air as well. The indicator
therefore provides a visual indication of the amount of air flowing to the brake pipe.
During initial charging or release of brakes, when a large quantity of air passed to the
brake pipe, the pressure at the out let port and in spring chamber reduces sufficiently. It
allows the supply pressure to lift the disc valve off its seat and permit unrestricted flow
of air to the brake pipe through Additional C2-Relay valve. Under these conditions a
high intermediate pressure builds up in the passages between chokes C and D, and the
indicator indicates a high rate of airflow.
Choke D is variable to facilitate calibration and may be altered by means of an adjusting
screw, turning the screw clockwise reduces the aperture and turning it anticlockwise
enlarges it.
25
1. Introduction
It is an air pressure gauge with two pointers. Red pointer is called reference
pointer, which is attached to a knurled knob and protrudes through the dial glass, so that
it can be set manually in any desired position, where as the other pointer moves on the
scale depending up on the air flow. The indicator is connected to the measuring valve
through R-6 relay valve. The scale on the gauge is calibrated not in the units of airflow
but in numbers which normally indicates the number of wagons. The 60 marks
correspond to the maximum rate of airflow that can be accepted to overcome leakage on
a 60 wagon train.
2. Objective
It is a device through which BP (Air brake train ) leakage can be seen in the
Drivers cabin.
3. Operation
When a train has been made up and the brake system is being charged with air before
moving off, there is a high rate of flow of air to the brake pipe and the indicator pointer
takes up a position in the uncalibrated sector of the scale. As the air pressure in the brake
pipe rises and the rate of airflow consequently diminishes, the indicator pointer falls
back. When the system is fully charged, it stabilises at a reading corresponding to the
airflow, to overcome leakage. If the train comprises 60 wagons, for example, this reading
is normally 60 or less, a higher reading indicates excessive leakage from the brake pipe.
At this stage, before starting the train, the driver sets the reference pointer to
coincide with the indicator pointer and thereby fixes a datum point on the scale. The
indicator pointer should return whenever the brake is fully released during the ensuing
journey, so long as the make- up of the train is not changed.
Therefore, during the journey, the indicator pointer falls below the reference
pointer or rises above it, indicates leakage decreased or increased respectively. During the
release process, the indicator pointer falls back steadily towards the reference pointer and
the deviation between the two pointers at any time indicates the state of release of the
brake. When the system is fully recharged the two pointers approximately coincide again,
if they do not coincide it is evident that the brake pipe leakage has changed and the
amount of deviation between the two pointers gives the driver some idea of the
magnitude of the change. An indicator pointer reading below the datum point shows that
the leakage has been reduced, conversely a higher reading indicates an increase in the
leakage. Some small variations are to be expected during a journey.
26
27
1. Introduction
R-6 Relay valve is a simple relay valve which provides air pressure in 1:1
ratio and is mounted just near the AFM valve. It is required because of long piping from
the AFM valve to the indicator.
2. Objective
This is a simple relay valve, which provides air pressure in 1:1 ratio and
mounted in between the indicator and the AFM valve. It is required because of long
piping from the AFM valve to the indicator and unavoidable leakage at joints in both the
cabs.
4. Construction
R6-Relay valve consists of the cast aluminum cover, houses the spring loaded
relay piston and tapped to receive an air pressure signal. The body also aluminum,
contains the combined inlet and exhaust valve and is tapped to provide two supply and
four delivery ports. A rubber disc protects the exhaust vent in the base.
5. Operation
When air pressure signal from AFM valve, is received at port A of the R-6
Relay valve, air flows in chamber C between the cover1 and the top of the relay piston
assembly 2. A relatively small-applied pressure reacts quickly over the larger area of the
relay piston 2 and forces the piston down against the spring 7. This movement of the
piston closes the exhaust passage 6 and the valve sheet 13 opens the inlet/exhaust
valve11, which is also moved down against the return spring 10. Air then flows from
main reservoir through port B to chamber D and from there it passes out of the delivery
port E. This flow continues until the force of the applied air pressure above the piston
balances the combined forces of the piston, valve return spring and the air pressure
beneath the piston. After getting balanced the piston moves up closing the inlet/exhaust
valve. The valve is now in the lapped condition with both the inlet and the exhaust
closed. If the signal pressure from air flow measuring valve is reduced at the port A the
force below the piston is now greater , and the piston rises until the valve seat 13 is lifted
clear of the valve allowing air to atmosphere past the rubber flap at 6 through the hollow
passage in the piston at 5. The exhaust of the air continues within the force below the
piston is reduced to balance t hat above the piston and the exhaust of air closes again,
bringing the valve in lap condition. This phenomenon is repeated wherever the applied
pressure at port A is varied, either up or down as the valve is self-lapping.
28
AIR DRYER
1. Introduction
Air dryer is a complete air cleaning and drying unit, which is provided in
between MR-1 and MR-2 of Diesel Locomotive. It helps to the Automatic Drain &
Check valve also by purging the Dryer system. Purging is the removal of collected
moisture from the desiccant beeds. Drying means the desiccant in the dryer is drying the
compressed air by absorbing the water vapour from the air passing through that tower. It
supplies dry and clean air to the locomotive brake system.
2. Objective
The primary purpose of the dryer is to provide dry, oil free and clean
compressed air to the locomotive brake system.
3. Construction
The current design consists of a borosilicate coalescing filter known as pre
coalescer and twin regenerative desiccant towers that operates simultaneously. These two
towers are connected to pre coalescer to remove oil and water aerosols. Pre coalescer and
dryer towers are connected by a common inlet and outlet manifold with solenoid
assembly. All the electrical controls, which program the sequence of operation, are
located in housing attached to the outlet manifold.
The first component is a multi layered Pre coalescing element. Two other layers
are constructed by small microscopic fibers, which are random in size to enhance the
collection of oil and water aerosols. The unit is mounted with aluminum housing with a
pneumatically operated double seated drain valve, attached to the sump.
The second component is a pneumatically controlled inlet check valve located
within the inlet manifold for each of the identically designed dryer tower. Each dryer
tower consists of finned aluminum housing containing a desiccant canister. This canister
includes a pneumatic compactor to hold the desiccant tightly within the canister to
minimise attrition or dusting of the desiccant and a mesh filter that is attached to the
bottom of the desiccant canister along with the pneumatically operated single seated
purge.
The third component is a spring-loaded outlet check valve mounted in the outlet
manifold of the dryer towers adjacent to the humidity indicators.
29
4. Function
Air from no.1 MR flows into the Air dryer inlet manifold down to the cell of
the pre coalescing element and exits through the pre coalescing element where oil and
water aerosols are collected. Air then flows up around the out side of the element and
through the interning manifold to both of the dryer towers. Contaminants such as oil and
water aerosols are collected in the element, migrate to the sump. These contaminants are
then discharged to the atmosphere through a double seated pneumatically operated drain
valve attached to the bottom of the pre coalescing sump. This valve is activated
momentarily each time of the dryer cycles. Filtered air leaving the pre coalescing element
passes through the manifold with pneumatically operated inlet check valve and inters the
top of each of the air dryer tower.
The internal design of the housing slings the air down word around desiccant
canister in a simplified path. This simplifical movement cools the air and separates
moisture from the air, which settles in the sump at the bottom of each tower. The air then
flows through a oval stainless steel mesh filter attached to the bottom of the desiccant
canister. The secondary filter restricts and collects all droplets and contaminants not
removed by the pre coalescing element. The filter is self cleaned each time the single
seated pneumatically operated purge valve is operated at bottom. The actuation of the
valve also expels to atmosphere any separated water, which is collected in the sump. The
air passing through the secondary filter now passes upward through the desiccant bed
where water vapour is absorbed by the desiccant beeds. The result is that the air existing
top of the canister is very dry with an extremely low relative humidity. The dry airs now
flows through the outlet manifold, which contains the humidity indicators and the outlet
check valve prier to entering the locomotive air system. The identical airflow through
both towers permits the maximum flow of air to charge the air system initially. When the
locomotive air system pressure reaches a pre determined point normally 100 psi+/-5, a
pressure switch within the dryer closes. This supplies power to the timing control circuit,
which energises the solenoid on one tower and the tower start purging.
5. Drying and purging cycle
There is an arrangement of drying and purging cycle, which is governed by
timer circuit. One tower drying by collecting moisture from air while the other purging
the collected moisture from the desiccant beeds. It continues for one minute. After oneminute timer circuit changes the position, the tower that was drying begins to purge and
the tower that was purging begins to dry air.
6. Timer circuit
The timer circuit is electronically timed to operate the tower. When air
pressure reaches 100 psi, the pressure switch closes. The timing circuitry energises the
solenoid on one tower, which provides pneumatic signal & closes the inlet check valve
and at the same time opens the purge valve at the bottom of the housing. Simultaneously
the spring loaded outlet check valve is closed and stops the flow of air to the tower. A
30
small amount of dry filtered air from the top of the drying tower flows through an internal
orifice and to the desiccant beeds removing collected moisture. At the same time the
opposite tower collects moisture from the compressed air, which passing through the
desiccant beeds. After one minute the electronic timer reverses the operation of the tower.
The purging tower now becomes the drying tower. The solenoid is de-energised which
causes the inlet and outlet check valves to open and the purge valve to close permitting
full air flow through the desiccant beeds that absorb water vapour. Simultaneously the
solenoid circuit on the opposite tower is energised.
7. Checking the proper function of the air dryer system
This is accomplished by inspecting the humidity indicators, which indicates as
follows.
Blue indicator--- indicates dryer has been performing correctly.
Lavender indicator--- dryer is suspect.
White indicator--- possible damaged dryer. Check for water in final filters.
Yellow or brown indicator--- damaged dryer.
31