The document describes the Delta Power System ES 48/90JBA01, which provides up to 5.4 kW of installed maximum power. It has a compact, modular design and features intelligent power monitoring and control. The system consists of compact rack enclosures, 1800W rectifier modules, and related power distribution units that are controlled by a Control and Supervisory Unit. It is designed for wireless and wireline network applications.
The document describes the Delta Power System ES 48/90JBA01, which provides up to 5.4 kW of installed maximum power. It has a compact, modular design and features intelligent power monitoring and control. The system consists of compact rack enclosures, 1800W rectifier modules, and related power distribution units that are controlled by a Control and Supervisory Unit. It is designed for wireless and wireline network applications.
The document describes the Delta Power System ES 48/90JBA01, which provides up to 5.4 kW of installed maximum power. It has a compact, modular design and features intelligent power monitoring and control. The system consists of compact rack enclosures, 1800W rectifier modules, and related power distribution units that are controlled by a Control and Supervisory Unit. It is designed for wireless and wireline network applications.
The document describes the Delta Power System ES 48/90JBA01, which provides up to 5.4 kW of installed maximum power. It has a compact, modular design and features intelligent power monitoring and control. The system consists of compact rack enclosures, 1800W rectifier modules, and related power distribution units that are controlled by a Control and Supervisory Unit. It is designed for wireless and wireline network applications.
Leaflet_ES48-1800-3 JBA05_en / rev. 1.0 / 06.2006 / Chad Tseng
www.deltaww.com Power System ES 48/90JBA01 Main features Up to 5.4 kW installed max. power User friendly user (LED) operation interface Wide input voltage range Module design, front access for simple maintenance Compact design, saves valuable floor space Intelligent remote system monitoring and control Applications Telecom, wireless, datacom Small power shelf for telecom power system Description Delta ES 48/90JBA01 series power system, consisting of compact rack enclosures, 1800W rectifier modules and related power distribution units, is under the control of Control and Supervisory Unit. User can operate the system via the user friendly LED interface. Meanwhile, with the Delta power system management software. Delta ES 48/90JBA01 series power system is designed to meet the demands of todays and tomorrows wireless and wire-line network applications. It combines a compact, modular design and intelligent power features. The ES 48/90JBA01 series power module is UL, TUV approved and manufactured in our modern ISO 9001 and TL 9000 certified facility. DELTA ELECTRONICS, INC. 3, Tung Yuan Road, Chungli Industral Park, Taoyuan Hsien 320 Taiwan, R.O.C. Phone: +886 3 452-6107 Fax: +886 3 452-7314 www.deltaww.com Power System ES 48/90 JBA01 Technical Specifications General Efficiency 91 % Losses, max. 148.5W (Per rectifiers) Safety TUV/CE UL/cUL (Per rectifiers) EMC EN 55022 Class A (Per rectifiers) Cooling Fan cooled rectifiers Input AC connection & Nominal voltage L-N + PE : 220 VRMS Range, full power 175 ... 275 VRMS Range, reduced power 90 ... 175 VRMS Frequency range 45 ... 66 Hz Current nominal L-N + PE: 36 A ARMS @ 5.4kW Inrush current < 12 Apeak per rectifier Harmonic distort. THD < 5 % Main switch AC Breaker Output Voltage, nominal Float: 54.0 VDC Equalize: 56.0 VDC Voltage range 40 ... 59.5 VDC Voltage regulation < 0.1 % Overvoltage protection 59.5 VDC Ripple + spikes 100 mVp-p Psophometric noise 2.0 mVRMS (weighted) Output current 90 ADC @ 54 VDC 90 ADC @ 48 VDC Power, maximum 5.4 kW Load distribution Load Distribution Power Distribution Unit 1. Main AC Breaker 2. Load Breaker 1x10, 2x20, 2x30A 3. Battery Breaker X 1 (100A Type) 4. Hall Sensor for Load current measurement 5. The PDU follow Customer request design 6. D/O eight relays output (From C Type ) LVBD 100A Mechanics Construction Power Shelf Height, overall 133.4 mm / 5.25 inch Width, body 482.6 mm / 19 inch Depth, overall 330.2 mm / 13 inch Weight, system 22 kg / 48.5 lb (w/o Rectifier) Weight, rectifiers ESR-48/30D A Type 3.1 kg / 6.83 lb Environment Ambient temperature -5 +50C / 23 122F Relative humidity 95 % max, non cond. Control and monitoring Power system controller Delta Smart CSU Display: LED display (Show DCV/DCI) Load Current AC ON Rectifier Fail Alarm (RFA) Current Limit (CL) Float/Equalize (FL/EQU) Major Alarm (MAJ) Minor Alarm (MIN) High Voltage Alarm (HV) High Voltage Shutdown (HVSD) Low Voltage Alarm (LV) Low Voltage Disconnect Open (LVDS OPEN) Fuse Blown (FUSE ALM) AC Fail (AC FAIL) Function System monitoring (remote/local) Parameter setting Temperature compensation Boost / Equalize charge Alarm relay definable Remote Interface RS-232 Port (Delta RMS software) Web Server Function (Optional) Accessories Rectifier blank panel Delta remote management software