SPC200 Smart Positioning Controller: Electronics Manual Stepping Motor Indexer Module Type SPC200 SMX 1
SPC200 Smart Positioning Controller: Electronics Manual Stepping Motor Indexer Module Type SPC200 SMX 1
SPC200 Smart Positioning Controller: Electronics Manual Stepping Motor Indexer Module Type SPC200 SMX 1
Stepping motor
indexer module
Type SPC200SMX1
Manual
188 895
en 0503b
[693 858]
SPC200 Smart Positioning Controller
Contents and general instructions
I Festo P.BESPC200SMX1EN en 0503b
Author P. Mauch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Editor M. Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Original de . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Translation transline Deutschland . . . . . . . . . . . . . . . . . . . . .
Layout Festo AG & Co. KG, Dept. KGGD . . . . . . . . . . . . . . . .
Type setting KIDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Edition en 0503b . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Designation P.BESPC200SMX1EN . . . . . . . . . . . . . . . . . . .
Order no. 188 895 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E (Festo AG & Co. KG, D73726 Esslingen, Federal Republic
of Germany, 2003)
Internet: http://www.festo.com
email: [email protected]
The reproduction, distribution and utilization of this docu
ment as well as the communicaton of its contents to others
without express authorization is prohibited. Offenders will
be held liable for the payment of damages. All rights re
served in the event of the grant of a patent, utility module
or design.
Contents and general instructions
II Festo P.BESPC200SMX1EN en 0503b
Contents and general instructions
III Festo P.BESPC200SMX1EN en 0503b
Contents
Designated use V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Target group VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Important user instructions VII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes on software version IX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Notes on the use of this manual X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
List of abbreviations XII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1. System summary 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 System structure 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Basis structure for operating a stepping motor axis 14 . . . . . . . . . . . . . . . . . . .
1.2.1 Connecting and display elements
of the stepping motor indexer module 17 . . . . . . . . . . . . . . . . . . . . . . .
1.3 Drive packages 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3.1 Stepping motor controller 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Electromechanical linear drive 111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 Accessories 111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6 EMERGENCY STOP concept 112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Fitting 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Fitting and removing the stepping motor indexer module 24 . . . . . . . . . . . . . . .
2.2 Fitting the electric axis and the stepping motor controller 27 . . . . . . . . . . . . . .
2.2.1 Arrangement of the sensors 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. Installation 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 General instructions 33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 Overview of electrical installation 35 . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Connecting the sensors 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Connecting the stepping motor controller and the stepping motor 38 . . . . . . .
3.4 Connecting the control cable 38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents and general instructions
IV Festo P.BESPC200SMX1EN en 0503b
4. Commissioning 41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Procedure for commissioning 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Preparations for commissioning 44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 Commissioning with WinPISA 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1 Selecting a specification for the axis 48 . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2 Configuration of the axis parameters 411 . . . . . . . . . . . . . . . . . . . . . . . .
4.3.3 Configuration of the application parameters 412 . . . . . . . . . . . . . . . . . .
4.3.4 Configuration of the settings for analogue reference value
specification 422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5 Loading the axis configuration into the SPC200 422 . . . . . . . . . . . . . . .
4.3.6 Functional check of the stepping motor axes 423 . . . . . . . . . . . . . . . . .
4.4 Commissioning with the control panel 427 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1 Setting projectspecific parameters 428 . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.2 Functional check of the stepping motor axes 430 . . . . . . . . . . . . . . . . .
4.5 Program example 434 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6 Instructions on operation 435 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5. Diagnosis and error treatment 51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 General instructions on diagnosis 53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2 Onthespot diagnosis 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3 Diagnosis with WinPISA 55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Diagnosis on the control panel 57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.5 Emergency travel 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.6 Notes on judging the positioning behaviour 511 . . . . . . . . . . . . . . . . . . . . . . . . .
A. Technical appendix A1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.1 Technical specifications A3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.2 Internal circuitry A4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.3 Index A7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents and general instructions
V Festo P.BESPC200SMX1EN en 0503b
Designated use
The stepping motor indexer module type SPC200SMX1 has
been designed for coupling a suitable stepping motor con
troller to the SPC200. With this stepping motor controller the
SPC200 can control a stepping motor axis. Maximum 3 step
ping motor indexer modules can be fitted in a rack.
Basic components and modules for the SPC200 are described
in the user manual type P.BESPC200... . The safety instruc
tions specified in the manuals must always be observed and
the relevant components and modules must only be used as
intended. Please observe also the safety instructions in the
operating instructions for the pneumatic components used.
The SPC200 and the modules and cables to be connected are
only to be used as follows:
As specified in industrial applications.
Without any modifications by the user.
Only the conversions or modifications described in the
documentation supplied with the product are permitted.
iIn faultless technical condition.
When used together with commercially available compo
nents, such as actuators, the specified limits for pressures,
temperatures, electrical data, torques etc. must be observed.
National and local safety regulations must also be observed.
Contents and general instructions
VI Festo P.BESPC200SMX1EN en 0503b
Target group
This manual is intended exclusively for technicians trained in
control and automation technology, who have experience in
fitting, installing, commissioning, programming and diagnos
ing stepping motor axes.
Service
Please consult your local Festo repair service if you have any
technical problems.
Contents and general instructions
VII Festo P.BESPC200SMX1EN en 0503b
Important user instructions
Danger categories
This manual contains instructions on the possible dangers
which may occur if the product is not used correctly. These
instructions are marked (Warning, Caution, etc.), printed on a
shaded background and marked additionally with a picto
gram. A distinction is made between the following danger
warnings:
Warning
This means that failure to observe this instruction may
result in serious personal injury or damage to property.
Caution
This means that failure to observe this instruction may
result in personal injury or damage to property.
Please note
This means that failure to observe this instruction may
result in damage to property.
The following pictogram marks passages in the text which
describe activities with electrostatically sensitive compo
nents.
Electrostatically sensitive components may be damaged if
they are not handled correctly.
Contents and general instructions
VIII Festo P.BESPC200SMX1EN en 0503b
Marking special information
The following pictograms mark passages in the text contain
ing special information.
Pictograms
Information:
Recommendations, tips and references to other sources of
information.
Accessories:
Information on necessary or sensible accessories for the
Festo product.
Environment:
Information on environmentfriendly use of Festo products.
Text markings
S The bullet indicates activities which may be carried out in
any order.
1. Figures denote activities which must be carried out in the
numerical order specified.
Hyphens indicate general activities.
Contents and general instructions
IX Festo P.BESPC200SMX1EN en 0503b
Notes on software version
Please note
This manual refers to stepping motor indexer modules
type SPC200SMX1 with software version as from 1.42.
Observe the different positioning speeds depending on the
software version of the stepping motor indexer module:
Function Range Software version
1)
Axis moves with
Reference
travel
Switching ranges of the
limit switches or the refer
ence switch (depending on
as from 1.42 StartStop frequency
ence switch (depending on
the reference travel mode)
or after a limit switch fault
as from 1.0 1/4 StartStop frequency
Outside the switching
ranges of the limit or refer
ence switches
all Reference speed
Emergency
travel
Switching range of the limit
switches and movement
before reaching the limit
as from 1.43
(in preparation)
StartStop frequency
before reaching the limit
switch up to 1.42 1/2 StartStop frequency
1)
Determining the software version see section 5.3
Contents and general instructions
X Festo P.BESPC200SMX1EN en 0503b
Notes on the use of this manual
This manual contains basic general information on fitting,
installing and commissioning the SPC200, as well as a de
scription of its method of operation as a stepping motor con
troller. The manual deals with the SPC200 Smart Positioning
Controller with operating system version as from 4.6 and
fitted stepping motor indexer module with firmware version
as from 1.42 (see section 5.3, Status display) as well as
WinPISA as from version 4.3.
Manuals on the SPC200 Smart Positioning Controller
Type
Title Contents
Systemmanual SPC200 Smart Positioning Controller,
user manual
type P.BESPC200...
Installation, commissioningand
diagnosis with SPC200; standard
components and modules
Software manual WinPISA software package
type P.SWWINPISA..
Functions of the WinPISA software
package
Help system Help system for WinPISA (contained
in WinPISA)
WinPISA help system
Manuals Field bus module
type P.BESPC200COM...
Installation, commissioningand
diagnosis of the relevant field bus
module
Stepping motor indexer module
type P.BESPC200SMX1...
Installation, commissioningand
diagnosis with a stepping motor
Electric positioning system
type P.BEATP...
Further information on electric
positioningsystems
Special information on commissioning, programming and
diagnosing the SPC200 with the WinPISA software package
can be found in the appropriate manual for WinPISA.
Contents and general instructions
XI Festo P.BESPC200SMX1EN en 0503b
Information on the electric axes, drive packages with step
ping motors and stepping motor controllers as well as sen
sors can be found in the documentation supplied with the
product.
Caution
If the permitted operating conditions of the components
used are not observed, faults may occur during operation.
Consider in particular the specifications for the permitted
operating conditions of the motors and drives used in the
documentation enclosed (manufacturer data), e.g. for the
permitted startstop frequency or the minimum positioning
speeds.
Contents and general instructions
XII Festo P.BESPC200SMX1EN en 0503b
List of abbreviations
The following productspecific terms and abbreviations are
used in this manual:
Term/abbreviation Meaning
Drive package Stepping motor controller, in some cases with gear
Electric axis Combination of motor, coupling (coupling housing with coupling and
flange), electromechanical linear axis, as well as the necessary
cables and sensors.
Electromechanical
Linear drive
Linear guide with spindle or toothedbelt drive
I Digital input
I/Os Digital inputs and outputs
Modules Function cards which can be plugged into the rack of the SPC200.
Q Digital output
Record Select mode Operating mode of the SPC200 which supports close coupling with a
higherorder PLC/IPC.
Resolution Steps per mm positioning path, depends on the motor used, the
drive as well from the configured step mode (see section 4.3.3).
Startstop frequency Frequency with which the stepping motor can start and stop reliably
at the required rotational speed (without loss of step).
Start/Stop mode Operating mode of the SPC200 which supports both autonomous
operation and control by a higherorder PLC/IPC.
Step mode The step mode defines the step width (rotary angle of the motor per
impulse). Therefore the steps per turn are defined too.
Systemsummary
11 Festo P.BESPC200SMX1EN en 0503b
Chapter 1
1. System summary
12 Festo P.BESPC200SMX1EN en 0503b
Contents
1. System summary 11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 System structure 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Basis structure for operating a stepping motor axis 14 . . . . . . . . . . . . . . . . . . .
1.2.1 Connecting and display elements of the
stepping motor indexer module 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Drive packages 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3.1 Stepping motor controller 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.4 Electromechanical linear drive 111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.5 Accessories 111 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.6 EMERGENCY STOP concept 112 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1. System summary
13 Festo P.BESPC200SMX1EN en 0503b
1.1 System structure
Stepping motor drives must be connected to the SPC200 by
means of special stepping motor indexer modules. Each step
ping motor indexer module type SPC200SMX1 enables a
stepping motor axis to be coupled on.
......
1
2
3
4
5
6
7
8
9
1 Programmer/PC for commissioning
2 SPC200 with stepping motor indexer
module
3 Stepping motor controller
4 Control cabinet
5 Electromechanical linear drive
6 Reference/limit switches
7 Coupling and flange
8 Motor, in some cases with gear
9 Pneumatic axis (optional)
Fig.1/1: System overview
1. System summary
14 Festo P.BESPC200SMX1EN en 0503b
1.2 Basis structure for operating a stepping motor axis
With just the following modules the SPC200 can control a
stepping motor controller:
1 2 3 4
1 Power supply module
2 Diagnostic module
3 I/O module (optional field bus module)
4 Stepping motor indexer module
Fig.1/2: Basis structure for a stepping motor controller
1. System summary
15 Festo P.BESPC200SMX1EN en 0503b
Module Description
Power supply module Enables the power supply and the axis
interface designed as a field device to be
connected.
Diagnostic module Enables the control panel to be fitted
and a PC to be connected.
I/O or field bus module Enables control of the I/Os or
communication via the field bus.
Stepping motor indexer
module
Enables a stepping motor controller to
be controlled.
A system structure with the modules shown above offers the
following facilities:
One or two pneumatic axes can be controlled
Control of one stepping motor axis
Programming and diagnosis via a PC or a control panel
Coordination via I/Os or via the field bus
Providing a sufficient number of unused locations are avail
able, up to 3 stepping motor indexer modules can be fitted in
the SPC200 for controlling 3 electric axes.
The SPC200 can be controlled via I/Os or via the field bus in
the operating mode Start/Stop or in the Record Select mode.
The address range required for this is provided by the I/O
module or the field bus module.
1. System summary
16 Festo P.BESPC200SMX1EN en 0503b
For setting up a stepping motor axis with the SPC200 you will
require the following components:
The SPC200 Smart Positioning Controller with stepping
motor module type SPC200SMX1
The control cable from the SPC200 to the stepping motor
controller (see manual for stepping motor controller)
A stepping motor drive package from Festo, consisting of
a stepping motor controller, a stepping motor and, in
some cases, also gears. Other stepping motor controllers
are possible, providing they have compatible connections.
Mains filter, fuses etc. for the stepping motor controller
Motor cable for connecting the stepping motor controller
and the stepping motor
Motor flange and coupling
Linear drive (e.g. DGE(L)...), with accessories
Suitable sensors for reference and limit switches
When selecting the sensors, note that the accuracy of the
switchover point of the sensors determines the accuracy of
the reference point.
You must make sure that the switchover point always lies
within a step resolution.
1. System summary
17 Festo P.BESPC200SMX1EN en 0503b
1.2.1 Connecting and display elements of the stepping motor indexer
module
The diagram below shows the connecting and display
elements of the stepping motor indexer module type
SPC200SMX1.
1 Control plug
(AMPLIFIER, X30),
15pin
2 FAULT LED (red)
3 STATUS LED
(green)
4 Signal plug
(SIGNALS, X31)
1
2
3
4
Fig.1/3: Connecting and display elements
1. System summary
18 Festo P.BESPC200SMX1EN en 0503b
1.3 Drive packages
Festo offers drive packages for electric axes. These consist of:
stepping motor controller
stepping motor (in some cases with brake)
gears (if necessary).
The drive package must be suited to the requirements of the
positioning system (moveable mass, positioning time, etc.) as
well as to the electromechanical linear axis used.
A stepping motor controller with a 5 V signal level must be
used for operating the SPC200 (see Technical specifica
tions").
1.3.1 Stepping motor controller
The stepping motor controller forms the link between the
SPC200 as positioning controller and a stepping motor.
The signals from the positioning controller are converted by
the stepping motor controller in accordance with the motor
dependent and drivedependent settings (e.g. phase current).
1. System summary
19 Festo P.BESPC200SMX1EN en 0503b
1 Power unit
2 Stepping motor
controller
3 Stepping motor
4 SPC200
(positioning
controller)
1
2
3
4
Control signals
Fig.1/4: Control connection of the stepping motor controller
The control connection of the stepping motor indexer module
type SPC200SMX1 has been optimized for the stepping
motor controllers offered with the Festo drive packages.
Other stepping motor controllers can only be used providing
the necessary inputs and outputs are compatible with the
control output of the stepping motor indexer module
(AMPLIFIER connection, see Technical specifications").
1. System summary
110 Festo P.BESPC200SMX1EN en 0503b
The control connection of the stepping motor indexer module
possesses the following inputs and outputs for connecting a
stepping motor controller:
Outputs (pushpull control, electric as per RS 485):
Pulse
Direction
Enable
Full/half step (not used with SECST)
Input (relay contact in the stepping motor controller):
Ready (bridged in the connecting cable for the SECST)
1. System summary
111 Festo P.BESPC200SMX1EN en 0503b
1.4 Electromechanical linear drive
Linear drives are used for the electric axes. These drives con
vert the rotary movement of the stepping motor into a linear
movement of the slide. If the linear drives do not have an inte
grated guide, an additional guide must be provided.
Two different types of guides are available:
axes with spindle drive, e.g. DGE(L)...SP
axes with toothedbelt drive, e.g. DGE(L)...ZR
Please note
The maximum length of the linear drives is determined by
technical reasons. As from a certain length, spindle drives
may only be operated at limited speed and toothedbelt
drives may only be operated with limited drive torque.
1.5 Accessories
For the positioning systems Festo offers accessories suited to
the drive packages and linear drives (see Festo delivery pro
gram or catalogue).
1. System summary
112 Festo P.BESPC200SMX1EN en 0503b
1.6 EMERGENCY STOP concept
Please note
Check within the framework of your EMERGENCY STOP
concept, to ascertain the measures necessary for putting
your machine/system into a safe state in the event of an
EMERGENCY STOP (e.g. switching off the load supply,
operating voltage for the stepping motor controller,
switching off the compressed air).
The status of the limit switches connected to the sensor plug
is evaluated by the operating system of the SPC200.
Warning
The limit switches connected to the sensor plug are not
suitable for implementing an EMERGENCY STOP function.
Use additional separate safety limit switches if an ap
propriate EMERGENCY STOP circuit is required for your
application.
Fitting
21 Festo P.BESPC200SMX1EN en 0503b
Chapter 2
2. Fitting
22 Festo P.BESPC200SMX1EN en 0503b
Contents
2. Fitting 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 Fitting and removing the stepping motor indexer module 24 . . . . . . . . . . . . . . .
2.2 Fitting the electric axis and the stepping motor controller 27 . . . . . . . . . . . . . .
2.2.1 Arrangement of the sensors 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2. Fitting
23 Festo P.BESPC200SMX1EN en 0503b
Warning
Before carrying out installation and/or maintenance work,
switch off the following in the sequence specified:
1. the compressed air supply
2. all load and operating voltage supplies on the SPC200
and the connected components of the positioning
system.
You can thereby avoid:
unexpected movements of the connected actuators
uncontrolled movements of loose tubing
undefined switching states.
2. Fitting
24 Festo P.BESPC200SMX1EN en 0503b
2.1 Fitting and removing the stepping motor indexer module
Caution
Modules may be damaged if they are not handled cor
rectly.
S Do not therefore touch the contacts of the components.
S Observe the regulations for handling electrostatically
sensitive components.
Discharge yourself electrostatically before fitting or removing
components in order to protect the components against dis
charges of static electricity.
Note the following when fitting the module:
The stepping motor indexer module can be fitted as de
sired into any of the slots 2 to 6. Individual identification
of all fitted modules takes place automatically.
The axis identifiers are assigned to the modules or the
connected axes in ascending order from left to right with
out gaps.
Maximum 3 stepping motor indexer modules can be
fitted.
If a stepping motor indexer module is fitted next to the
diagnostic module, a control panel cannot be connected
because of the plug for the cable to the stepping motor
controller.
The modules are fastened on the rack with the aid of a lock
ing lever. A tool is not therefore required for fitting or remov
ing a module.
2. Fitting
25 Festo P.BESPC200SMX1EN en 0503b
Warning
Actuators may make sudden unexpected movements and
the SPC200 will be damaged if modules are added or re
moved whilst the power supply is switched on. Before
carrying out installation and/or maintenance work, switch
off the following power supplies in the sequence specified:
1. the compressed air supply
2. all load and operating voltage supplies on the SPC200
and the connected components of the positioning
system.
Fitting modules Proceed as follows when fitting a module into the rack:
1. Switch off the compressed air supply and the operating
voltage supply.
2. If necessary, remove blanking plate.
3. Hold the module by the front plate and push it into the
guide rail. Make sure that the modules are not tilted when
they are pushed in and that no components on the
printed circuit board are damaged.
4. Make sure that the plugs of the terminal strips are cor
rectly aligned. Then gently push the module in as far as
possible. The retaining levers will then lock automatically
(see diagram).
2. Fitting
26 Festo P.BESPC200SMX1EN en 0503b
1 Direction for
unlocking
2 Locks
automatically
3 Retaining lever
4 Front plate of the
module
5 Terminal strip
6 Guide rail
1
2
3
4
5 6
1
Fig.2/1: Installing the modules
Removing modules Proceed as follows when removing a module:
1. Switch off the operating voltage and the compressed air
supply.
2. Loosen and pull off the connecting cable on the front of
the module.
3. Unlock both locking levers (see diagram) and carefully
pull out the module.
4. If necessary, seal the unused slots with blanking plates.
2. Fitting
27 Festo P.BESPC200SMX1EN en 0503b
2.2 Fitting the electric axis and the stepping motor controller
Notes on fitting the electric axis and the stepping motor
controller can be found in the following documentation:
the documentation supplied with the stepping motor
controller,
the pneumatics manual for the positioning system type
P.BEATP...,
the operating instructions for the electric linear axis used,
the instructions for the components used.
Please note
By the arrangement of the limit switches and by additional
appropriate mechanical stops, make sure that the axis
always lies within the positioning range limited by the
hardware limit switches.
Use the correct type of switch for the necessary reference and
limit switches:
Sensor Contact
Reference switch N.O. =normally open
Limit switches N.C. =normally closed
2. Fitting
28 Festo P.BESPC200SMX1EN en 0503b
2.2.1 Arrangement of the sensors
Please note
Please note that:
the axis must be in the positioning range in order to
carry out reference travel.
the complete ranges outside the permitted positioning
range are covered by limit switches (the slide must
never stand between the switching range of the hard
ware limit switch and the mechanical limit stop).
the switching range of the hardware limit switch, e.g. in
the event of programming faults, must permit destruc
tivefree braking (stroke reserve).
The usual arrangement of the sensors on an electric axis with
safety limit switches is shown in the following diagram.
2. Fitting
29 Festo P.BESPC200SMX1EN en 0503b
LIM REF
LIM+
1
2
3
4
5
6
Strokereser ve Strokereser ve
Brakingrange Brakingrange
1 Sensor connections for control
2 Sensor connections for the
EMERGENCY STOP circuit
3 Positioning range
4 Switching range of the reference
switch
5 Switching ranges of the hardware limit
switch (braking range < stroke reserve)
6 Switching ranges of the safety limit
switch (EMERGENCY STOP range)
Fig.2/2: Arrangement of the sensors
Installation
31 Festo P.BESPC200SMX1EN en 0503b
Chapter 3
3. Installation
32 Festo P.BESPC200SMX1EN en 0503b
Contents
3. Installation 31 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 General instructions 33 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 Overview of electrical installation 35 . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Connecting the sensors 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Connecting the stepping motor controller and the stepping motor 38 . . . . . . .
3.4 Connecting the control cable 38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3. Installation
33 Festo P.BESPC200SMX1EN en 0503b
3.1 General instructions
Warning
Before carrying out installation and/or maintenance work,
switch off the following in the sequence specified:
1. the compressed air supply
2. all load and operating voltage supplies on the SPC200
and the connected components of the positioning
system.
Load and operating voltage supplies:
The load voltage supply for field devices and proportional
directional control valves (plug X2, pin 1)
The load voltage supply for the outputs (plug X6/X8,
pin8)
If applicable, the load voltage supply on the axis interface
string
The operating voltage supply for the internal electronics
of the SPC200 and field devices (plug X2, pin 2)
The sensor supply on the stepping motor indexer module
(connection SIGNALS, pin 4)
The operating voltage supply on the stepping motor con
troller
You can thereby avoid:
undesired movements of the connected actuators
uncontrolled movements of loose tubing
undefined switching states
damage to the electronic components.
3. Installation
34 Festo P.BESPC200SMX1EN en 0503b
Please note
Connection to the main power supply and the fitting of
mains switches, transformers, fuses and mains filters may
only be carried out by a qualified electronics engineer.
Caution
Place motor cables and control cables at a distance from
each other where possible, e.g. in cable channels with in
termediate walls. Use only screened cables for connection
to the motor. Twist the control cables in pairs.
In this way you can avoid electromagnetic interference which
might impair reliable operation of the system.
Please note
Lay all moveable motor and sensor cables free of bends
and free of mechanical stress, if necessary, in a drag chain.
3. Installation
35 Festo P.BESPC200SMX1EN en 0503b
3.1.1 Overview of electrical installation
1 2
3
4
5
6
7
9
8
aJ
1 Motor
2 Electromechanical linear drive
3 Motor cable
4 Sensor cable
(reference and limit switches)
5 Control cabinet
6 SPC200 with stepping motor indexer
module
7 Control cable (e.g. KSPCSECST...)
8 Stepping motor controller
(e.g. SECST)
9 Main switch
aJ Power unit
Fig.3/1: Overview of electrical installation
3. Installation
36 Festo P.BESPC200SMX1EN en 0503b
3.2 Connecting the sensors
Warning
S Use only PELV circuits as per IEC/DIN EN 602041 (Pro
tective ExtraLow Voltage, PELV) for the electrical supply.
Consider also the general requirements for PELV circuits
in accordance with IEC/DIN EN 602041.
S Use power supplies which guarantee reliable electrical
isolation of the operating voltage as per IEC/DIN EN
602041.
By the use of PELV circuits, protection against electric shock
(protection against direct and indirect contact) is guaranteed
in accordance with IEC/EN 602041 (Electrical equipment for
machines, General requirements).
Please note
Check within the framework of your EMERGENCY STOP
circuit to ascertain the measures necessary for putting
your machine/system into a safe state in the event of an
EMERGENCY STOP (e.g. switching off the operating volt
age, switching off the compressed air).
3. Installation
37 Festo P.BESPC200SMX1EN en 0503b
1 LIM+: Positive
limit switch
2 REF: Reference
switch
3 LIM: Negative
limit switch
4 24 V: Supply
5 0 V: Supply
6 Earth/ground
connection
1
2
3
4
5
6
6
Fig.3/2: Pin assignment of sensor plug (SIGNALS, X31)
Use the correct type of switch for the necessary limit and
reference switches (see section Fitting").
When selecting the sensors, note that the accuracy of the
switchover point of the sensors determines the accuracy of
the reference point.
You must make sure that the switchover point always lies
within a step resolution.
The following diagram shows as an example the connection of
the sensors.
LIM+
REF
LIM
24V
0V
24V
0V
AC
DC
Fig.3/3: Connection diagram for the sensors
3. Installation
38 Festo P.BESPC200SMX1EN en 0503b
3.3 Connecting the stepping motor controller and the stepping motor
Fit the stepping motor controller and the motor cable in
accordance with the accompanying description.
Please note
In order to comply with EMC, a mains filter may have to be
installed between the mains supply cable and the stepping
motor controller.
3.4 Connecting the control cable
There is a subD plug on the stepping motor indexer module
for connecting the SPC200 to the stepping motor controller
(AMPLIFIER, X30).
This plug has been designed for stepping motor controllers
with 5 V control signals.
Use the special cables from the Festo range for connecting
the stepping motor controller.
If you use a stepping motor controller from a different manu
facturer, you must prepare a cable in accordance with the
manufacturers instructions.
In this case, connect the cable screening on both sides with
the plug housing.
3. Installation
39 Festo P.BESPC200SMX1EN en 0503b
1
1
2
8
.
.
.
9
15
.
.
.
1 AMPLIFIER connection
Fig.3/4: Control plug (AMPLIFIER, X30)
Pin assignment of control plug (AMPLIFIER, X30)
Pin Signal SECST Pin Signal SECST
1 + PULSE Clk + 5 9 PULSE Clk
2 + DIRECTION Dir + 5 10 DIRECTION Dir
3 + ENABLE En + 5 11 ENABLE En
4 Not connected 12 Not connected
5 + F/H STEP (full/half step)
1)
13 Not connected
6 F/H STEP (full/half step)
1)
14 Not connected
7 Not connected 15 READY
1)
2)
8 + READY
1)
2)
1)
Not used with stepper motor controller SECST
2)
Connections bridged in the connecting cable
3. Installation
310 Festo P.BESPC200SMX1EN en 0503b
Meaning of the signals on the control plug:
Signal Meaning
+/ READY Input:
Readiness of the stepping motor controller via
relay contact.
+/ PULSE Output:
Step control for the motor; each rising signal edge
corresponds to a step.
+/ DIRECTION Output:
Determines the direction of rotation of the motor.
+/ ENABLE Output:
Enable signal for the stepping motor controller.
+/ F/H STEP Output:
Defines whether the motor is controlled for full or
half step.
Commissioning
41 Festo P.BESPC200SMX1EN en 0503b
Chapter 4
4. Commissioning
42 Festo P.BESPC200SMX1EN en 0503b
Contents
4. Commissioning 41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 Procedure for commissioning 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Preparations for commissioning 44 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 Commissioning with WinPISA 47 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.1 Selecting a specification for the axis 48 . . . . . . . . . . . . . . . . . . . . . . . .
4.3.2 Configuration of the axis parameters 411 . . . . . . . . . . . . . . . . . . . . . . . .
4.3.3 Configuration of the application parameters 412 . . . . . . . . . . . . . . . . . .
4.3.4 Configuration of the settings for analogue reference value
specification 422 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3.5 Loading the axis configuration into the SPC200 422 . . . . . . . . . . . . . . .
4.3.6 Functional check of the stepping motor axes 423 . . . . . . . . . . . . . . . . .
4.4 Commissioning with the control panel 427 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.1 Setting projectspecific parameters 428 . . . . . . . . . . . . . . . . . . . . . . . . .
4.4.2 Functional check of the stepping motor axes 430 . . . . . . . . . . . . . . . . .
4.5 Program example 434 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.6 Instructions on operation 435 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4. Commissioning
43 Festo P.BESPC200SMX1EN en 0503b
4.1 Procedure for commissioning
For userfriendly commissioning and programming of an
SPC200 with stepping motor indexermodule, you will require
the WinPISA software package as from version 4.3.
However, commissioning can also be carrried out by means of
the control panel.
The following list provides an overview of the steps required
for commissioning:
1. Check the stepping motor controller. Set the necessary
parameters on the stepping motor controller. Check the
function and arrangement of the limit switches.
Provide the necessary system inputs on the SPC200
(seePreparingcommissioning).
General commissioning of the SPC200:
2. First check and save the hardware configuration of the
SPC200 (see WinPISA or SPC200 manual).
Commissioning the stepping motor axes:
3. Set the axis and application parameters for the stepping
motor axes to be used.
4. Check the function of the stepping motor axes:
Inputs (reference and limit switches)
Rotational direction of the stepping motor
Positioning the axis
Reference travel
5. Check that each axis has been correctly commissioned by
means of a simple test program.
4. Commissioning
44 Festo P.BESPC200SMX1EN en 0503b
4.2 Preparations for commissioning
Check the connection to the mains power supply
S Make sure that the stepping motor controller and the
SPC200 are disconnected from the power supply.
Check the voltage for the stepping motor controller and the
24 V power supply.
Check that the stepping motor controller is correctly
installed
S Check the installation of the stepping motor controller in
accordance with the accompanying documentation.
Set the parameters of the stepping motor controller
Caution
The stepping motor and the stepping motor controller may
be damaged when under tension if the presettings are
incorrect.
Leave the main switch switched off until all the parameters
have been set correctly.
S Check the settings on the stepping motor controller
(see manual for the stepping motor controller), e.g.:
the phase current
the step size
the step mode (or Micro/Half step)
the direction of rotation
the current reduction.
4. Commissioning
45 Festo P.BESPC200SMX1EN en 0503b
The settings of the maximum phase current depend on the
stepping motor connected. The maximum permitted phase
current is specified on the type plate of the stepping motor.
Caution
Excessive currents can damage the motor.
Do not set a current higher than that specified for the
motor, as otherwise the motor will be overloaded.
Select the next lower value if the specified current cannot be
set.
Please refer to the documentation on the stepping motor con
troller for the correct presettings and for instructions on opti
mizing the settings.
Switching on the power supply on the SPC200
Please note
Make sure that the axis is always within the positioning
range defined by the limit switches when it is switched on
and before the start of reference travel.
When you have checked the installation and parametrizing of
the stepping motor controller, switch on the power supply for
the SPC200.
4. Commissioning
46 Festo P.BESPC200SMX1EN en 0503b
Electric linear axis
Proceed as described in the operating instructions for the
electric linear axis.
Check especially the position and functioning of the limit
switches.
Carry out the first tests as follows:
with the compressed air switched off (providing pneu
matic axes are connected to the SPC200)
without work load
with disconnected coupling.
If the motor continues to run when the power supply for the
stepping motor controller is switched on, switch off the power
supply immediately and check the signal connections as well
as the earth and power cables.
System inputs for commissioning
With some commissioning steps, e.g. the signals ENABLE,
START and STOP are required for controlling the axes. For
commissioning stepping motor axes e.g. with the steps:
Move to reference point
In some cases emergency movement (diagnosis and fault
treatment)
Test and start program
Instructions on providing the signals can also be found in the
SPC200 or WinPISA manuals, in some cases also in the man
ual for the field bus module.
4. Commissioning
47 Festo P.BESPC200SMX1EN en 0503b
4.3 Commissioning with WinPISA
For commissioning with WinPISA you must simulate the
existing hardware configuration in WinPISA. Refer here to the
WinPISA manual for the necessary steps.
With the existing stepping motor indexer module there are
one or several stepping motor interfaces in the project win
dow under the SPC200. A stepping motor axis is assigned to
each stepping motor interface.
Fig.4/1: Stepping motor interface
Configuring the axis In order to configure a stepping motor axis, select the icon of
the axis in the project window. With the command [Edit]
[Configure] or with a double click on the axis icon, you can
open the relevant dialogue window Parameter set for the
..axis."
Caution
Incorrectly set parameters can lead to uncontrolled reac
tions of the connected axes during operation.
4. Commissioning
48 Festo P.BESPC200SMX1EN en 0503b
Fig.4/2: Parameter set for the .. axis, register card
Axisparameters"
4.3.1 Selecting a specification for the axis
A large number of settings and parameters must be defined
for an electric axis.
Specifications for drive packages can be selected for this pur
pose. The specifications are saved in planning files (*.pta). A
series of typical specifications can be found in the delivery
scope of WinPISA. You can create these specifications your
self with the aid of the Planning Tool (PtTool).
Information on further necessary entries can be found in the
following sections.
4. Commissioning
49 Festo P.BESPC200SMX1EN en 0503b
Please note
The SPC200 with stepping motor indexer module can be
used with various stepping motor controllers.
By selecting an appropriate specification for the axis, you
determine the following:
the calculation of the resulting resolution,
the support of the control output F/HSTEP of the step
ping motor indexer module.
Select the specification for the axis as follows:
1. Press the button Select" in the dialogue window Para
meter set for the .. axis," in order to select a specification.
2. In the dialogue window Axis selection" under Projected
axes," all the electric axes are displayed which exist in the
standard directory for planned axes.
With Search" you can also display axes from a different
directory.
Fig.4/3: Axis selection (stepping motor controller SECST)
4. Commissioning
410 Festo P.BESPC200SMX1EN en 0503b
3. Select from the list Projected axes" the axis which corre
sponds to the actual axis of your positioning system (see
following table). Accept the specification with Ok."
Controller Motor Effects in WinPISA and in the SPC200
Newdrive package
from Festo with
stepping motor
controller SECST.
MTRST... The stepping motor controller supports the step modes
1/1, 1/2, 1/4, 1/5, 1/8 and 1/10 step. The stepping mode
is set by means of the DIP switch on the controller.
The step mode set on the stepping motor controller must
be set in WinPISA WinPISA calculates fromthis the resul
Newdrive package
from Festo with inte
grated stepping motor
controller MTREST.
MTREST...
be set in WinPISA. WinPISA calculates from this the resul
ting resolution which is saved in the SPC200 (see section
4.3.3).
1)
Output F/HSTEP of the stepping motor indexer module is
not used.
Old drive package from
Festo with stepping
motor controller
MRC...
VRDM... (or
MTRVRDM...)
The stepping motor controller supports Full/Half step
modes.
With the setting Half step," output F/H STEP of the
stepping motor indexer module will be set when the
stepping motor controller is actuated.
1)
WinPISAsupports for the MTREST... only the step modes 1/1 and 1/2.
Please note
The new drive packages with stepping motor controller
SECST are supported only with WinPISA as from version
4.3 and SPC200 as operating system version 4.6.
Check and, if necessary, correct the settings in the register
cards Axis parameters" and Application parameters" as
described in the following sections.
The specifications for the axes in the delivery scope of
WinPISA are usually preset on the step mode 1/2 as well as
on a startstop frequency of 400 Hz.
4. Commissioning
411 Festo P.BESPC200SMX1EN en 0503b
4.3.2 Configuration of the axis parameters
Check and, if necessary, correct the settings in the register
card Axis parameters" in accordance with your system.
Description of the parameters under
Axisparameters"
The axis parameters are configuration data which describe
the composition, the properties and the components of the
axis used.
When an axis is inserted from the Planning Tool, the appropri
ate information on the linear drive is shown in the display
fields. After an upload these fields appear empty, as this in
formation is not saved in the SPC200.
Designation The designation of the linear drive used for the electric axis
(display field).
Length The length of the linear drive used for the electric axis
(see type plate).
Permitted: 50 ... 10.000 [mm]
Diameter The size of the linear drive used for the electric axis
(see type plate, parameter only for information).
Permitted: 8 ... 320 [mm]
Motor The designation of the stepping motor used for the electric
axis (display field).
Steps/turn The number of steps per turn of the stepping motor used for
the electric axis (display field).
Gear The designation of the gear used for the electric axis (display
field).
4. Commissioning
412 Festo P.BESPC200SMX1EN en 0503b
4.3.3 Configuration of the application parameters
Check and, if necessary, correct the settings in the register
card Application parameters" in accordance with your
system.
Fig.4/4: Parameter set for the .. axis, register card
Application parameters"
Description of the parameters under Application
parameters"
The application parameters are configuration data which de
scribe the conditions of use specified by the application.
4. Commissioning
413 Festo P.BESPC200SMX1EN en 0503b
Resolution with full step Steps per mm positioning path with step mode Full step"
(1/1):
Resolutionwithfullstep +
stepsturn
feedconstant <transmissionratio
Permitted: 0.01000 ... 9999.99999 [1/mm]
Description of the parameters:
Parameters Description
Steps/turn Number of steps per revolution of the stepping
motor:
(step angle see type plate)
stepsturn +
360
stepangle
Feed constant Feed in mm per turn of the input shaft (linear
axis)
Transmissionratio Transmission ratio i of the gear (see type plate)
Example:
Steps/turn (step angle = 1.8) = 200 1/turn
Feed constant = 32 mm/turn
Transmission ratio = 1 (no gears)
Resolutionwithfullstep +
200Stepsturn
32mmturn <1
+6.25000Stepsmm
Please note
The parameter Resolution with full step" us only used to
determine the final resolution, but not saved in the
SPC200.
Only the parameters Resolution" and "Step mode" are
saved.
4. Commissioning
414 Festo P.BESPC200SMX1EN en 0503b
Stepper mode
(MICRO/HALF STEP)
New as from WINPISA 4.3:
Step mode of the stepping motor controller.
The parameter "Stepper mode" replaces the parameter
Micro/half step (control panel: MICRO/HALF STEP) of previ
ous WinPISA and operating system versions.
Function and setting possibilities of the parameter depend on
the selected axis and on the stepping motor controller (see
following table and section 4.3.1).
Selected
motor
Stepping motor
controller
Step
mode
Output
F/H STEP
Meaning
MTRST... SECST 1/1
1/2
1/4
1/5
1/8
1/10
0
0
0
0
0
0
The setting of the step mode must
correspond to the DIL switch settings
on the controller.
The resulting resolution will be
calculated as per formula (see
Resolution").
The output F/H STEP on the stepping
motor indexer module of the SPC200
MTREST... Motor with
integrated
controller
1/1
1/2
0
0
motor indexer module of the SPC200
is not supported, it remains at 0"
irrespective of mode.
The control panel always shows 0"
(see section 4.4.1).
VRDM...
(or MTR
VRDM...)
MRCWS... Full step
Half step
0
1
With half step the output F/H STEP
will be set on the stepping motor
indexer module of the SPC200.
Newas fromWinPISA 4.3:
The resulting resolution will be
calculated automatically as per
formula (see "Resolution").
With the control panel the step mode
can be modified (0 or 1, see section
4.4.1).
Please note
The parameter Stepper mode" will be saved together with
the resulting Resolution" in the SPC200.
4. Commissioning
415 Festo P.BESPC200SMX1EN en 0503b
The specifications for the axes in the delivery scope of
WinPISA are usually preset on the step mode 1/2 as well as
on a startstop frequency of 400 Hz.
Recommendation:
In order to achieve smaller susceptibility for resonance ef
fects, operate 2phase stepping motors with step mode 1/2.
Note that the torque of the motor is thereby reduced.
Resolution Steps per mm positioning path resulting from the resolution
with full step" (1/1) and the selected step mode.
The following applies:
Resolution +resolutionwithfullstep <
1
2
4
5
8
10
withstepmode
1/1
1/2
1/4
1/5
1/8
1/10
Accuracy: 0.01000 ..9999.99999 [1/mm]
Startstop frequency Frequency with which the stepping motor can start and stop
reliably at the required rotational speed (without loss of
step).
Permitted: 80 ... 5000 [Hz]
Caution
By unfavorable choice of the startstop frequency reson
ance effects can occur with positioning the axis, which can
lead to step losses.
Consider the manufacturer data for the permitted operat
ing conditions of the used motors and drives, e.g. for the
permitted startstop frequency.
4. Commissioning
416 Festo P.BESPC200SMX1EN en 0503b
With the following parameters 3 to 6 (see Fig.4/5) you
can specify the reference points of your positioning system.
The machine zero point is defined by the coordinate of the
reference point. All further positions refer to the thus defined
machine zero point.
1 Machine zero
point
2 Reference and
limit switches
3 Reference
position
4 Lower software
end position
5 Upper software
end position
6 Project zero point
LIM REF
LIM+
1 2
3
4
5
6
2 2
Fig.4/5: Reference points
Project zero point Point related to the machine zero point. All positions in posi
tion registers and programs refer to the project zero point.
Permitted: 0.0 ... 10.0000 [mm]
Lower software end
position
Defined end position on the side of the machine zero point
which is monitored by the SPC200 and which must not be
overrun. The lower software end position refers to the ma
chine zero point and represents the lower limit of the posi
tioning range.
Permitted: 0.0 ... 10.0000 [mm]
4. Commissioning
417 Festo P.BESPC200SMX1EN en 0503b
Upper software end
position
Defined end position on the side opposite the machine zero
point which is monitored by the SPC200 and which must not
be overrun. The upper software end position refers to the
machine zero point and represents the upper limit of the
positioning range.
Permitted: 0.0 ... 10.0000 [mm]
If both software end positions are set to 0," their function
will have no effect.
Reference position Coordinate of the reference point related to the machine zero
point. The machine zero point is defined by this value based
on the switching point of the reference switch.
Permitted: 0.0 .. 10.0000 [mm]
The exact position of the switching point of the reference
switch depends on the selected reference travel mode.
Reference speed factor With this factor the positioning speed V
Ref
of the reference
travel, related to the configured maximum speed, is deter
mined (see Fig.4/6).
Permitted: 0.01 ... 1.00
Caution
By unfavorable choice of the reference speed factor reson
ance effects can occur with the reference travel of the axis.
Consider the manufacturer data for the permitted operat
ing conditions of the used motors and drives, e.g. for the
permitted speeds.
Recommendation:
Do not set the reference speed less than the startstop fre
quency.
4. Commissioning
418 Festo P.BESPC200SMX1EN en 0503b
Please note
When specifying the maximum speed and maximum accel
eration, take into account the limits of the linear axis used
(maximum permitted speed and feed force).
Maximum speed Speed for positioning with command G00 or maximum speed
for positioning with command G01. The speed factor speci
fied with command G01 refers to the maximumspeed defined
here.
Permitted: 0.1 ... 10.0 [m/s]
Note that the maximum permitted step frequency (position
ing frequency) with the SPC200 is 40 kHz. The maximum step
frequency is calculated from the product of the resolution
and the maximum speed:
Stepfrequency +resolution <speed
Maximum acceleration Maximum acceleration for positioning with the commands
G00 and G01. The acceleration factor specified with the com
mand G08 refers to the maximum acceleration defined here.
Permitted: 0.1 ... 100.0 [m/s
2
]
Note that due to too small accelerations resonance effects
can occur.
4. Commissioning
419 Festo P.BESPC200SMX1EN en 0503b
Determined number of revolutions and runup
period
From the set application data the maximum number of revol
utions as well as the runup period are determined and indi
cated:
Value Description
Revolution Number of revolutions with the configured maximumspeed and resolution:
Example:
Revolution +
Resolutionwithfullstep <Maximumacceleration
Stepsturn
Revolution +
6.25
1
mm
<1000
mm
m
<0.2
m
s
<60
s
min
200
1
U
+375
turns
min
Runupperiod Time, in which the drive with the max. acceleration configured reaches the maxi
mum speed:
Example:
Run *upperiod +
Maximumvelocity
Maximumacceleration
Run *upperiod +
0.2
m
s
2.0
m
s
2
+0.1s
Reference travel mode Mode with which reference travel is to be carried out. This
presetting applies to reference travel which has been
started:
in the dialogue window Commissioning the stepping
motor" (Command [Online] [Commission] [Stepping
motor]),
or with the control panel.
Permitted: 0 ... 4
With command G74 the reference travel mode in the NC pro
gram will be defined individually.
4. Commissioning
420 Festo P.BESPC200SMX1EN en 0503b
Reference travel modes (see also Fig.4/6):
Mode Description
0 Accepting the current axis position as reference point
1 Reference travel in negative direction to reference switch
(REF) with acceptance as reference point
2 Reference travel in negative direction to negative limit
switch (LIM) with acceptance as reference point
3 Reference travel in positive direction to reference switch
(REF) with acceptance as reference point
4 Reference travel in positive direction to positive limit
switch (LIM+) with acceptance as reference point
Note that reference travel with modes 1 and 3 will result in
different reference points.
During reference travel the axis moves according to Fig.4/6.
The mechanical arrangement of the reference or limit
switches clearly determines the reference point of an axis. In
each case, the position accepted as reference point is that at
which the slide leaves the switching range of the sensor.
Caution
If an incorrect reference travel mode is set, this can lead to
collisions, as all positions of the axis refer to the reference
point.
When carrying out reference travel, make sure that the
correct mode is used.
4. Commissioning
421 Festo P.BESPC200SMX1EN en 0503b
1 Starting position
2 Position accepted
as reference
point
3 Switching ranges
of end and
reference
switches
Speeds during reference
travel:
V
Ref
: Reference speed
factor * maximum
speed
SS: Startstop fre
quency
LIM REF LIM+
Mode0:
Mode1:
Caseb:
Mode2:
Mode3:
Mode4:
Casea:
Casea:
SS V
Ref
V
Ref
SS
SS SS
V
Ref
SS
SS
V
Ref
SS
V
Ref
SS
SS
V
Ref
SS
1
2
3 3 3
Caseb:
Fig.4/6: Reference travel modes
After a limit switch fault, the axis loses the reference point.
When the fault has been eliminated, new reference travel
must be carried out with the axis.
If reference travel is started after a limit switch fault (without
Power off/on), the axis will try to leave or find the last actu
ated switch with the startstop frequency (SS). If the switch is
neither left nor found, the axis will move to the opposite limit
switch.
4. Commissioning
422 Festo P.BESPC200SMX1EN en 0503b
4.3.4 Configuration of the settings for analogue reference value
specification
The settings for analogue reference value specification in the
register card Analogue reference value" are identical to the
settings for pneumatic axes.
Information on the settings can be found in the WinPISA
manual.
4.3.5 Loading the axis configuration into the SPC200
Providing the hardware configuration of the SPC200 corre
sponds to the project, you can load the configured values into
the SPC200 in the dialogue window Parameter set for the
..axis."
The online mode must be active for this purpose. If necessary,
close the dialogue window Parameter set for the .. axis" and
activate the online mode.
While the online mode is active, load the relevant data in the
individual register cards into the SPC200 with the button
Download."
4. Commissioning
423 Festo P.BESPC200SMX1EN en 0503b
4.3.6 Functional check of the stepping motor axes
When the axis and application parameters have been set,
check that the axes function correctly.
Preparations for the functional check:
S Check to see if the coupling between the motor and the
linear axis has been loosened. If this is not the case,
loosen the coupling.
S Leave the stepping motor controller switched off. If
necessary, switch this off.
S When the axis moves in accordance with the functions in
the dialogue window Commission stepping motor," it
moves in each case at the set reference speed.
If necessary, set a lower reference speed factor during the
functional check of the axes.
Proceed with the functional check as follows:
1. Select the command [Stepping motor] in the menu
[Online] [Commissioning] in active online mode. The
dialogue window Commission stepping motor" will be
displayed.
4. Commissioning
424 Festo P.BESPC200SMX1EN en 0503b
Fig.4/7: Dialogue window Commission stepping motor"
Checking the inputs 2. Make sure that the end and reference switches function
correctly. In order to do this, you can move the axis by
hand when the stepping motor controller is switched off.
Select the desired stepping motor axis under Axis
selection." Check the checkboxes of the relevant inputs
under Status of the inputs."
Note the different designs of sensors:
Limit switches (end switches): N.C., normally closed
Reference switch: N.O., normally open
4. Commissioning
425 Festo P.BESPC200SMX1EN en 0503b
3. Make sure that the axis is always within the positioning
range defined by the limit switches when it is switched on
and before the start of reference travel.
Now switch on the stepping motor controller. Under
Status of the inputs," the checkbox Servo ready" shows
that the stepping motor controller is ready to operate.
Checking the direction
of rotation
4. By actuating the arrow buttons under Procedure," you
can determine the direction in which the motor is to ro
tate.
The motor should only rotate when the relevant button is
actuated.
Check the direction of rotation with regard to the result
ing direction of movement of the axis. If necessary,
switch off the stepping motor controller again and adjust
the direction of rotation.
Positioning the axis 5. If the steps up till now have been carried out without any
faults, you can now connect the coupling and move the
axis with the arrow buttons under Procedure." The axis
will then move at the configured reference speed.
Check that the limit switches function correctly. In order to
do this, move the axis up to the limit switches: the posi
tive limit switch switches when moving in the positive
direction; the negative limit switch switches when moving
in the negative direction.
4. Commissioning
426 Festo P.BESPC200SMX1EN en 0503b
With the function Emergency travel," you can move into
the positioning range again after a limit switch has been
actuated. Select here the option Emergency travel"
under Activity" and start this with Start."
The axis moves in the reverse direction (towards the posi
tioning range providing the limit switch is connected cor
rectly), until the limit switch is left. Travel is interrupted if
the limit switch is not left within 2 seconds or if the button
Stop" is actuated.
Reference travel 6. Select the option Reference travel" under Activity."
Check the mode displayed for reference travel.
Start reference travel with the button Start." During
reference travel the button Start" changes to Stop."
With Stop" you can interrupt the current reference
travel.
The relevant position of the axis, related to the position
of the machine zero point, is shown under Procedure."
After successful reference travel the functional check of the
axis is completed.
4. Commissioning
427 Festo P.BESPC200SMX1EN en 0503b
4.4 Commissioning with the control panel
If you wish to carry out commissioning with the control panel
type SPC200MMI1, you should be familiar with the functions
of the control panel. Leave the power supply for the stepping
motor controller (if necessary, also the compressed air sup
ply) switched off. An overview of the menu system on the
control panel can be found in the user manual for the
SPC200.
Please note
The control panel type SPC200MMI.. does not support all
new or extended functions of the SPC200 with firmware as
from version 4.6.
The prerequisite for commissioning a stepping motor axis is
that the current hardware configuration of the SPC200 is
saved (see user manual for the SPC200).
Proceed here as described in the following sections.
4. Commissioning
428 Festo P.BESPC200SMX1EN en 0503b
4.4.1 Setting projectspecific parameters
Cautio
Incorrectly set parameters can lead to uncontrolled reac
tions of the connected axes during operation.
The SPC200 must know the conditions of use in your project
and the type of components used in your positioning system.
Undertake the necessary settings in the following menus:
Menu Description
SPC200 READY
AXIS PARAM. >
Axis parameters;
Specifications on the axes used
SPC200 READY
APPLIC. PARAM.>
Application parameters;
Specifications on the conditions of use
When you have selected a menu, use the arrow buttons to set
the axis identifiers of the stepping motor axis to be confi
gured and confirm this with the ENTER key:
AXIS PARAM. >>
X:
You can then set the parameters described below.
4. Commissioning
429 Festo P.BESPC200SMX1EN en 0503b
Axis parameters
Menu AXIS PARAM Set the following parameters (description of the parameters
see section Commissioning with WinPISA"):
Menu AXIS PARAM (axis parameters)
CYL. LENGTH Length of drive
Application parameters
Menu APPLIC PARAM Set the following parameters (description of the parameters
see section Commissioning with WinPISA"):
Menu APPLIC PARAM (application parameters)
RESOLUTION Resolution
START/STOP FREQ Startstop frequency
POS. BASEPOINT Project zero point
LOWER END POS. Lower software end position
UPPER END POS. Upper software end position
REFER. POSIT. Reference position
REFER. SPEED Reference speed factor
MAX. SPEED Maximumspeed
MAX. ACCELER. Maximumacceleration
MODE OF REFER. Reference travel mode
MICRO/HALF STEP Step mode (Micro/Half step)
with SECST...: always 0
with MRC...: 0 or 1
(see following sections)
4. Commissioning
430 Festo P.BESPC200SMX1EN en 0503b
On the control panel display the parameter MICRO/HALF
STEP corresponds to the step mode (see section 4.3.3).
If stepping motors type MTRST with the corresponding
power unit type SECST are used or the integrated motor
unit MTREST, the value 0" will always be shown. It must
not be modified with the control panel.
If stepping motors type "VRDM" are used and with the
corresponding power unit type "WS5", the stepper mode
can be modified with the control panel (0 or 1).
With the parameter RESOLUTION the resulting resolution will
be displayed and can be modified.
4.4.2 Functional check of the stepping motor axes
When the axis and application parameters have been set,
check that the axes function correctly.
1. Preparations for the functional check:
S Check to see if the coupling between the motor and
the linear axis has been loosened. If this is not the
case, loosen the coupling.
S Leave the stepping motor controller switched off. If
necessary, switch this off.
S When the axis moves in accordance with the functions
in the dialogue window Commission stepping motor,"
it moves in each case at the set reference speed.
If necessary, set a lower reference speed factor during
the functional check of the axes.
4. Commissioning
431 Festo P.BESPC200SMX1EN en 0503b
Check the inputs 2. Make sure that the end and reference switches function
correctly. In order to do this, you can move the axis by
hand when the stepping motor controller is switched off.
Select the command STEP MOTOR INPUT in the menu
DISPLAY and press the Enter key.
The cursor is positioned on the axis identifier. Select the
desired axis with v or V and position the cursor on the
entry LIM+ with }.
STEP MOTOR INPUT
Y: LIM+ = 1
With v or V switch between the inputs. The state of the
individual input is shown with 0" or 1."
When checking the sensors, note their different designs:
LIM+, LIM:
Limit switches (end switches): N.C., normally closed
REF:
Reference switch: N.O., normally open
3. Make sure that the axis is always within the positioning
range defined by the limit switches when it is switched
on and before the start of reference travel.
Now switch on the stepping motor controller. The input
Servo ready" (SRDY) shows with a 1signal that the
stepping motor controller is ready to operate.
4. Commissioning
432 Festo P.BESPC200SMX1EN en 0503b
Checking the direction
of rotation
4. Select the command AXIS in the menu TEST/DIAG and
press the Enter key. With v or V select the identifier of
the stepping motor axis and confirm the selection with
the Enter key.
You are now in the menu TEST/DIAG AXIS.
Accept the command JOG AXIS with the Enter key. The
cursor is positioned on the sign +" after the coordinate
specification.
JOG AXIS
Y:+0000.00 +
With v or V you can switch between +" for positive
direction and " for negative direction.
By pressing the Enter key, you can determine the direc
tion in which the motor is to rotate.
The motor should only rotate when the Enter key is
pressed.
Check the direction of rotation with regard to the resulting
direction of movement of the axis. If necessary, switch off
the stepping motor controller again and adjust the direc
tion of rotation.
Positioning the axis 5. If the steps up till now have been carried out without any
faults, you can now connect the coupling and move the
axis in the relevant set direction with the Enter key.
Check that the limit switches function correctly. In order to
do this, move the axis up to the limit switches: the posi
tive limit switch switches when moving in the positive
direction; the negative limit switch switches when moving
in the negative direction.
If necessary, check the status of the limit switches on the
control panel (command STEPMOTOR INPUT, see Step 2).
4. Commissioning
433 Festo P.BESPC200SMX1EN en 0503b
With the function Emergency travel," you can move into
the positioning range again after a limit switch has been
actuated. In order to do this, select the command EXIT
FROM LIMIT in the menu TEST/DIAG AXIS with } and
confirm this with the Enter key.
EXIT FROM LIMIT
Y:+0326.88 ?
Start emergency travel with the Enter key.
The axis moves in the reverse direction (towards the posi
tioning range providing the limit switch is connected cor
rectly), until the limit switch is left. Travel is interrupted if
the limit switch is not left within 2 seconds or if the Esc or
Enter key is pressed during reference travel.
Reference travel 6. If necessary, check again the configured mode for refer
ence travel.
Select the command REFERENCE TRAV in the menu
TEST/DIAG AXIS with }.
Start reference travel with the Enter key.
The relevant position of the axis, related to the position
of the machine zero point, is displayed:
REFERENCE TRAV.
Y:+0100.00
The current reference travel can be interrupted with the
Esc key or with the Enter key.
After successful reference travel the functional check of the
axis is completed.
4. Commissioning
434 Festo P.BESPC200SMX1EN en 0503b
4.5 Program example
Enter a simple test program in order to check the configur
ation and the axis setup.
Program some positioning movements.
Proceed as described in the section Commissioning ..." in
the SPC200 manual or in the WinPISA manual.
The test program for a stepping motor axis can contain e.g.
the following records:
NC record Description
N000 G74 Y1
1)
2)
Reference travel in negative direction to
reference switch (REF)
N001 G04 100 Dwell time of 1 s
N002 G01 Y100 FY10
1)
Move at 10 % of the defined maximum
speed to Y = 100 mm
N003 G01 Y500 FY50
1)
Move at 50 % of the defined maximum
speed to Y = 500 mm
N004 G04 100 Dwell time of 1 s
N005 M30 Programend with repeat
1)
Use the axis identifier of the stepping motor axis
2)
Reference travel mode appropriate for the axis
Then check the program sequence as described in the
SPC200 manual or in the WinPISA manual.
4. Commissioning
435 Festo P.BESPC200SMX1EN en 0503b
4.6 Instructions on operation
Take the following instructions and recommendations into
account when programming positioning systems with electric
axes:
Please note
Make sure that all stepping motor axes:
always lie within the positioning range defined by the
limit switches when they are switched on and before the
start of reference travel.
carry out reference travel when the SPC200 or the step
ping motor controller is switched on or, if applicable,
after faults.
Stepping motor axes are operated in an open control loop.
Modifications to the position of the axis when the holding
torque is switched off (e.g. stepping motor controller
switched off by EMERGENCY STOP), or lost steps" (e.g.
collision, overload) cannot therefore be taken into account.
Please note
Take into account any functions implemented within the
framework of the EMERGENCY STOP concept in the NC
programs.
Note that not all programming commands of the SPC200 are
valid for electric axes, and that individual programming com
mands for electric and pneumatic axes differ from each other
in their function (see SPC200 manual or WinPISA manual).
Follow the maintenance instructions for the components
used.
4. Commissioning
436 Festo P.BESPC200SMX1EN en 0503b
Caution
By positioning the axis with unfavorable positioning
speeds resonance effects can occur, which can lead to step
losses.
Consider the manufacturer data for the permitted operat
ing conditions of the used motors and drives, e.g. for the
permitted startstop frequency or for the permitted posi
tioning speeds.
Factors of influence for the positioning speeds:
Factors of influence Observe with
StartStop frequency
Reference speed factor
Maximumspeed
Maximumacceleration
Parametrizing
(Commissioning)
Speed factor (FX...) during positioning
with G01
Acceleration factor (G08) during posi
tioning with G01
Operation
Recommendation:
Make sure during operation that the minimum positioning
speed is never less than the startstop frequency set (see
manufacturer data of the components used).
Note that due to too small accelerations resonance effects
can occur.
The resonant frequency is for drives with 2phase stepping
motors usually between 50 and 250 Hz.
Diagnosis and error treatment
51 Festo P.BESPC200SMX1EN en 0503b
Chapter 5
5. Diagnosis and error treatment
52 Festo P.BESPC200SMX1EN en 0503b
Contents
5. Diagnosis and error treatment 51 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 General instructions on diagnosis 53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.2 Onthespot diagnosis 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3 Diagnosis with WinPISA 55 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Diagnosis on the control panel 57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.5 Emergency travel 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.6 Notes on judging the positioning behaviour 511 . . . . . . . . . . . . . . . . . . . . . . . . .
5. Diagnosis and error treatment
53 Festo P.BESPC200SMX1EN en 0503b
5.1 General instructions on diagnosis
Information on general diagnosis and fault treatment can be
found in the manual for the SPC200 type P.BESPC200... or in
the WinPISA manual.
This chapter contains special information on diagnosing the
stepping motor indexer module.
General diagnostic possibilities
The SPC200 offers extensive and userfriendly possibilities of
diagnosis and fault treatment. The following possibilities are
available:
The LEDs on the stepping motor module display informa
tion on the operating status of the connected stepping
motor axis.
The LEDs on the SPC200 and on the connected field de
vices show directly configuration faults, hardware faults,
string faults, bus faults, etc.
The control panel shows detailed fault messages coded in
the form of an 8figure hexadecimal number.
In online mode WinPISA shows the 8figure fault message
as well as a description of the fault in clear text.
The output bit READY of the SPC200 shows the basic
readiness of the system to operate.
5. Diagnosis and error treatment
54 Festo P.BESPC200SMX1EN en 0503b
5.2 Onthespot diagnosis
The two LEDs on the stepping motor indexer module enable a
speedy onthespot diagnosis to be made:
FAULT LED (red)
STATUS LED (green)
FAULT LED
(red)
STATUS LED
(green)
Operating status
is off is off Operating voltage not applied
lights up is off Function card has not started; SPC200 defective or function card
defective; servicingrequired
lights up flashes for a
long time
Limit switch actuated, short circuit or incorrect polarity at sensor
input or internal fault
is off flashes briefly Initialization phase Reference travel not carried out or reference
travel no longer valid (Servo Ready interrupted)
is off flashes for a
long time
Operating status normal no axis movement/positioningtask
is off lights up Axis moves
Description of the LED signals
Signal Description Signal Description
ON
OFF
is off
ON
OFF
flashes for a long
time
ON
OFF
lights up
ON
OFF
flashes briefly
5. Diagnosis and error treatment
55 Festo P.BESPC200SMX1EN en 0503b
5.3 Diagnosis with WinPISA
In online mode WinPISA offers the following possibilities of
diagnosing stepping motor axes:
Status display
Display of the inputs of the stepping motor indexer
module
Further notes and diagnostic possibilities can be found in the
WinPISA manual or in the online help.
Status display In order to display the status, select the command [Status
display] in the menu [Online] [Diagnosis].
Select the axis identifier of the desired stepping motor axis in
the register card System."
Under Software version" the software version of the step
ping motor indexer module is displayed.
Whether or not reference travel has been carried out is shown
after the entry Reference travel."
Fig.5/1: Status display, register card System
The other entries correspond to the display for a selected
pneumatic axis (see WinPISA manual).
5. Diagnosis and error treatment
56 Festo P.BESPC200SMX1EN en 0503b
Display inputs In order to display the status of the inputs, select the
command [Stepping motor module] in the menu [Online]
[Observe].
Fig.5/2: Observe stepping motor module
The inputs are shown by means of checkboxes as follows:
Checkboxes Input Description Remedy
End switch positive
(Limit switch
positive)
LIM+ When the checkbox is
deactivated, the positive limit
switch (N.C.) is actuated.
Push the axis into the
positioning range (if
necessary emergency travel)
End switch negative
(Limit switch
negative)
LIM When the checkbox is
deactivated, the negative limit
switch (N.C.) is actuated.
Push the axis into the
positioning range (if
necessary emergency travel)
Reference switch REF When the checkbox is
activated, the reference
switch (N.O.) is actuated.
C
20 ... + 70
C
Weight 69 g
Relativehumidity 95%, noncondensing
Connection SIGNALS (X31)
External supply (pin 4, pin 5)
Sensor inputs (pin 1 ... 3)
Current consumption (at 24 V)
Reference potential
24 V DC, 15 %
1)
Inputs based on IEC 11312 type 2
24 V DC, positiveswitching (PNP)
Typ. 8 mA
0 V
ConnectionAMPLIFIER (X30)
2)
Input (+/ READY)
Outputs (+/ DIRECT, +/ PULSE,
+/ ENABLE, +/ F/H STEP)
Step frequency
Frequency ramp
Positioningrange
Resolution
+ 24 V (connected internally with pin 4 of the SIGNALS
plug) via relay contact
Pushpull control (electric as per RS 485)
80 Hz ... 40 kHz
Max. 500 kHz/sec
0.00 ... 9999.99 mm
0.01000 ... 9999.99999 steps/mm
Electromagnetic compatibility
Interference emitted
Resistance to interference
Tested as per DIN EN 6100064 (industry)
3)
Tested as per DIN EN 6100062 (industry)
Vibration and shock
Vibration
Shock
Tested as per DIN/IEC 68 part 26;
(0.15 mm path at 10 ... 58 Hz,
2 g acceleration at 58...150 Hz)
Tested as per DIN/IEC 68 part 227;
( 30 g at 11ms duration; 15 cycles)
1)
Note the tolerance of the connected sensors.
2)
Pincompatible with the stepping motor controllers of the Festo drive package for 5 V control
signals.
3)
The SPC200 is intended for industrial usage.
A. Technical appendix
A4 Festo P.BESPC200SMX1EN en 0503b
A.2 Internal circuitry
Circuitry of control connection (AMPLIFIER, X30)
Circuitry of the outputs (+/ DIRECT, +/ PULSE,
+/ ENABLE, +/ F/H STEP):
+...
...
SPC200 Steppingmotorcontroller
Fig.A/1: Principle RS 485 / RS 422
Circuitry of the inputs (+/ READY):
+READY
READY
SPC200 Steppingmotorcontroller
(+24Vfrom
sensorplug)
Fig.A/2: Relay contact
On the connecting cable for the SECST the input READY is
bridged.
A. Technical appendix
A5 Festo P.BESPC200SMX1EN en 0503b
Circuitry of sensor connection (SIGNALS, X31)
Circuitry of the inputs (LIM+, REF, LIM):
SPC200 Sensors
4k7
24V
0V
24V
0V
(supply)
LIM+
Fig.A/3: Sensor inputs
A. Technical appendix
A6 Festo P.BESPC200SMX1EN en 0503b
A. Technical appendix
A7 Festo P.BESPC200SMX1EN en 0503b
A.3 Index
A
Abbreviations XII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AMPLIFIER connection 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Analogue reference value 422 . . . . . . . . . . . . . . . . . . . . . . . .
Application parameters 412, 429 . . . . . . . . . . . . . . . . . . . . . .
Axis parameters 411, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B
Basis structure 14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C
Commissioning 43 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connecting elements 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control panel 427, 57 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control plug 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
D
Designated use V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnosis
Diagnosis on the control panel 57 . . . . . . . . . . . . . . . . . . . .
Diagnosis with WinPISA 55 . . . . . . . . . . . . . . . . . . . . . . . . . .
General instructions 53 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Onthespot diagnosis 54 . . . . . . . . . . . . . . . . . . . . . . . . . .
Diameter of drive 411 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display elements 17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drive packages 18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A. Technical appendix
A8 Festo P.BESPC200SMX1EN en 0503b
E
Electromechanical linear drive 111 . . . . . . . . . . . . . . . . . . . .
EMERGENCY STOP concept 112 . . . . . . . . . . . . . . . . . . . . . . .
Emergency travel 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
End switches 56 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F
FAULT LED 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Functional check of the stepping motor axes 423, 430 . . . . .
H
Half step 414, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I
Important user instructions VII . . . . . . . . . . . . . . . . . . . . . . . . .
Instructions on operation 435 . . . . . . . . . . . . . . . . . . . . . . . .
Internal circuitry A4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
J
Judging the positioning behaviour 511 . . . . . . . . . . . . . . . . .
L
LEDs 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Length of drive 411, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limit switches 27, 28, 56, 58 . . . . . . . . . . . . . . . . . . . . . . . .
Lower software end position 416, 429 . . . . . . . . . . . . . . . . . .
A. Technical appendix
A9 Festo P.BESPC200SMX1EN en 0503b
M
Maximumacceleration 418, 429 . . . . . . . . . . . . . . . . . . . . . . .
Maximum speed 418, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Micro step 414, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
P
Pictograms VIII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Positioning behaviour 511 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Program example 434 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Project zero point 416, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . .
R
Reference points of the positioning system 416 . . . . . . . . . .
Reference position 417, 429 . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference speed factor 417, 429 . . . . . . . . . . . . . . . . . . . . . .
Reference switch 27, 28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference travel 419 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference travel mode 419, 429 . . . . . . . . . . . . . . . . . . . . . . .
Resolution 413, 415, 429 . . . . . . . . . . . . . . . . . . . . . . . . . . .
S
Sensor plug 37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sensors 16, 36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SIGNALS connection 37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Size of drive 411 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Software end position 416, 417, 429 . . . . . . . . . . . . . . . . . .
Software version IX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Startstop frequency 415, 429 . . . . . . . . . . . . . . . . . . . . . . . .
A. Technical appendix
A10 Festo P.BESPC200SMX1EN en 0503b
STATUS LED 54 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step mode 414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stepping motor controller 18, 44 . . . . . . . . . . . . . . . . . . . . . .
System structure 13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
T
Target group VI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical specifications A3 . . . . . . . . . . . . . . . . . . . . . . . . . . .
Text markings VIII . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
U