Relay

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

SONGLE RELAY

RELAY ISO9002
SLA



















3. ORDERING INFORMATION
1. MAIN FEATURES
Up to 30A switching in SPST and 20A switching in spot
arrangements.
Available as an open-frame relay,
with a snap-on dust cover or with an immersion cleanable,
plastic sealed case.
2. APPLICATIONS
Used for power switching, Electrical Heater, ventilator,
Air conditioning,
Refrigerating, Automobile and House-hold Appliance.
SLA XX VDC S L C
Model of relay Nominal coil voltage Structure Coil sensitivity Contact form
A:1 form A
S:Sealed type

L:0.93W
B:1 form B

SLA

0506091218
2448110VDC
F:Flux free type D:Special C:1 form C


4. RATING
20A/28VDC 250VAC 30A/30VDC 250VAC
CCC FILE NUMBER:CQC03001003728 30A/250VDC
UL/CUL FILE NUMBER: E179944 NO:20A/240VAC 28VDC NC:10A/240VAC 28VDC
TUV FILE NUMBER: R50056114 NO:30A/250VAC 30VDC NC:20A/250VAC 30VDC
5. DIMENSION
(unit:mm)
DRILLING
(unit:mm)
WIRING DIAGRAM



1
www.datasheet4u.com




Coil
Sensitivity
Coil
Voltage
Code
Nominal
Voltage
(VDC)
Nominal
Current
(mA)
Coil
Resistance
() 10%
Power
Consumption
(W)
Pull-In
Voltage
(VDC)
Drop-Out
Voltage
(VDC)
Max-Allowable
Voltage
(VDC)
05 5 185 27
06 6 150 40
09 9 93 97
12 12 77 155
15 15 59 256
18 18 47 380
24 24 36 660
48 48 20 2480

110 110 9 13000




abt. 0.93W




75%
Max.




10% Max.




120%Max.

SLA
FORM C
Type

Item

FORM A FORM B












30A



20 A
10 A




6. COIL DATA CHART (AT20 C)









SLA






7. CONTACT RATING




N/O N/C
9.REFERENCE DATA


OPEN-STYLE RELAY,
Resistive
Load
(cos=1)
General
Motor
30A 250VAC
30A 30VDC
250VAC 2HP
120VAC 1HP
15A 250VAC
10A 30VDC
250VAC
0.5HP
120VAC
0.25HP
20A 250VAC
20A 30VDC
250VAC 2HP
120VAC 1HP
10A 250VAC
10A 30VDC
250VAC 0.5HP
120VAC 0.25HP


120
110
100
90
80

NO DUST COVER
Ballast 10A 277VAC 3A 277VAC 10A 277VAC 3A 277VAC
70

60
LRA/FLA 240VAC 80/30 240VAC 30/10 240VAC 50/20 240VAC 20/7
50
40

8. PERFORMANCE (at initial value)
Type



SLA

30
20
0.4


0.6


0.8


1.0


1.2


1.4


1.6


1.8


2.0
Item
Contact Resistance 100m Max.
Operation Time 15msec Max.
Release Time 10msec Max.
Dielectric Strength




160

140
Coil Power (W)


SEALED RELAY
Between coil & contact
Between contacts
2000VAC
1500VAC

120

100
Insulation Resistance 100 M Min. (500VDC) 80

30A

20A

Operating Ambient
Temperature

-25 to +70C (storage)
20


0


10A
Operating Humidity 45 to 85% RH
0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Coil Temperature Rise 60 deg. Max.
Vibration
Coil Power (W)
Endurance
Error Operation
Shock
Endurance
Error Operation
Life Expectancy
Mechanically
Electrically
10 to 55Hz Double Amplitude 1.5mm
10 to 55Hz Double Amplitude 1.5mm

100 m/sec
2
(abt. 100gs)
10 m/sec
2
(abt. 10gs)

10
7

10
5

Weight abt. 20grs, 24grs(SEALED)
UL File No. E179944



2
www.datasheet4u.com