TECHNICAL CHARACTERICS

1. FLASH CONTROLLER IDM8200


Flash Controller IDM 8200 is encapsulated in a wall mounted steel cabin. Protection
degree is IP21 and the Controller has to be installed indoors.
There are two different cabin sizes for different types of Flash Controllers: standard
size and smaller size(for systems that has only RTIL).



Supply voltage for the Flash Controller is 400 VAC + N + PE, 50 Hz. The Controller
requires a fuse bank of 40 A. It monitors and adjusts the energy supplied for each
light unit. Adjusting is done by regulating current using thyristors.

The Controller is a microprocessor based system. The intensity level can be
selected locally with a rotary switch or it can be set to remotely controlled mode. The
unit has also an user panel for control of system settings like: system status,
detected lamp faults and other faults, etc.

The Controller has a built-in power supply for heaters installed on the Elevated Flash
Light Unit IDM 6291. There are also options available such as:
- Runway threshold identification lights control which automatically shuts down
both units in the case of lamp fault.
- Surge arrester.
- Earth fault protection.


2. INSET FLASH LIGHT IDM 2061
All components of IDM 2061 are made of high quality materials that guarantee
reliability and long life - time of light unit. The prisms are sealed with silicon gaskets
which enables easy replacement when prisms have become worn - out.


The light source of the unit is a 40 J xenon tube (same type that is used on Elevated
Flash Light Unit IDM 6291). The unit is controlled by trigger PCB and installed on a
standard 12 shallow (or deep) base with an operation temperature range between
40C and +55C.





3. ELEVATED FLASH LIGHTUNIT IDM 6291
Elevated Flash Light Unit IDM 6291 has a fibreglass housing on cast aluminium
assembly plate and mechanically strong front glass. This construction combines high
protection degree with light weight


The unit has a metal coated aluminium reflector and a built-in alignment device to adjust
it to correct elevation angle (between 1... 8). The Light source of this unit is a 40 J
xenon discharge tube.



The unit is installed at the end of a 60 mm pipe and wiring is done through this
pipe. Typically the unit is mounted on a safety mast and a
mast adapter is to be used. Other types of adapters, pipes, frangible couple etc. can
be also used as mounting base

4. JUNCTION BOX IDM 8205
Junction Box IDM 8205 consists of a plastic enclosure and a stainless steel fixing
frame. Protection degree is IP65 and the box is meant for outdoor installation
connecting cables from the main cable line to single light unit. Inside the box there
are terminals for wires. The box is equipped with suitable cable inlets, necessary
fuses and residual current protector (-I model applicable for Inset Light Unit IDM
2061 only). As an option, also a surge arrester is available










SQFL + RTIL


Only RTIL