RDM - HSB-3

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

HSE-3

LABORATORY HEAT SEALER



PRECISION LABORATORY HEAT SEALER FOR PRODUCTION OF REPEATABLE HIGH
QUALITY HEAT SEALS AND DETERMINATION OF HEAT SEAL THRESHOLD.
PRODUCES SEALS 5 TO 25MM WIDE AND UP TO 300MM LONG.


Benefits:
Choose heat sealing bar configuration, either single
(upper) or dual (upper & lower, meets ASTM F2029)
User can easily change sealing bar for various surface
areas or surface finishes
Accurate and repeatable seals due to precision ground
sealing faces and jaw guidance system
Versatile applications for flexible materials, blister
packs and pots
Low Maintenance - 12 months between calibrations

Features:
Precise pressure calibration of standard surface area
jaw face
Temperature, pressure and dwell time digital
controllers
Jaws constructed in aluminium and silicon with
precision ground faces
Range of jaw face surfaces including Matched Crimp
and Teflon Coating
Auto cycle feature for greater user convenience with
multiple samples RDM Test Equipment
Unit 39 Golds Nurseries Bus. Park
Jenkins Drive, ELSENHAM
Hertfordshire, CM22 6JX, UK

Tel: +44(0)1279 817171
Fax: +44(0)1279 815743
E-mail: [email protected]
Web: www.rdmtest.com
Sealing Bars Flat
Sealing Bars - Crimp
ASSURED QUALITY
TESTING SOLUTIONS
Specification
Seal Width 300 mm max. (Option to extend to 350mm)
Temperature
Control
Range: Ambient to 300C, Accuracy: +/- 0.5%, Operating Accuracy:
+/-2C. Single (Upper) sealing jaw temperature control, or Dual
(Upper & Lower) sealing jaw temperature control
Pressure Range: 0 to 100psi (6.8bar, 689Kpa), via precision regulator and
digital display. Accuracy +/-5%, Repeatability +/- 0.02psi .
Supply via clean and dry compressed airline or bottled air/nitrogen
at 90 to 100psi
Dwell Time Range: 0.1 to 99.9 sec., Resolution 0.01 sec
Auto Cycle &
Delay Time
Delay Time Range: 0.1 to 99.9 sec
For automatic cycling of sealing bars used in manual production
environments. Assists with correct alignment of sample. Electronic
processor controlled.
Jaw Guidance
System
Dovetail slide on jaws with quick release mechanism.
Sealing Jaws Standard flat jaws 25mm x 300mm, constructed in aluminium with
precision ground face. Lower sealing jaw with precision ground
silicone rubber face.
(See options below)
Environment: 5-50C ambient operating temperature,
RH 75% max (non-condensing)
Power 240V AC 50/60 Hz (110V AC voltage available
on request)
Options
Single (Upper) sealing jaw temperature control or Dual (Upper & Lower) sealing
jaw temperature control
Sealing jaw dimension/profile as required (inc. Matched crimp 120 x 1.8mm pitch)
Stainless Steel sealing jaws
Teflon Coated Tape or Teflon Coated Jaws
Blister Pack Simulator sealing jaw
Additional Blister tray
Footswitch
PVC Dust Cover
Alarm package for temperature High/Low, selectable
Cold seal system
Digital thermometer with s/s band probe to check jaw temperature (see image)
RDM Test Equipment
Unit 39 Golds Nurseries Bus. Park
Jenkins Drive, ELSENHAM
Hertfordshire, CM22 6JX, UK

Tel: +44(0)1279 817171
Fax: +44(0)1279 815743
E-mail: [email protected]
Web: www.rdmtest.com
ASSURED QUALITY
TESTING SOLUTIONS

You might also like