The manual covers installation, programming, operation and maintenance of the Genmega G1900 ATM.
The main components discussed include the cash dispensing unit, receipt printer, control board and operating environment specifications.
The steps include preparing an SD card with the update.acu file, creating Common/img4SCR folders, copying graphic files in the specified format and enabling the graphics in the customer setup menu.
Genmega G1900
Ask about Free
Custom Welcome Screen Graphics & Press Releases for our clients Table of Contents Genmega Operator Manual
G1900 Genmega 2011 TABLE OF CONTENTS
1. INTRODUCTION 1.1 Features 1.1.1 Genmega G1900 Series ATM 1.2 Specifications Genmega G1900 Specifications 1.2.1 Dimensions and Component Locations 1.2.2 Front Panel Identification 1.2.3 Cash Dispensing Unit 1.2.4 Receipt Printer 1.2.5 Main Control Board 1.2.6 Operating Environment 1.3 Warranty/Service
3. PROGRAMMING 3.1 Initial Setup 3.1.1 Accessing the Operator Function Menu 3.1.2 When An Error Occurs 3.1.3 EPP Keypad 3.2 The Host Setup Menu 3.2.1 Key Management 3.2.2 Set Terminal ID Number 3.2.3 Connect Timer 3.2.4 Set Routing ID Number 3.2.5 Set Host Telephone Number 3.2.6 Health Check Message 3.2.7 Remote Monitor 3.2.8 Trial Day Total 3.3 The System Setup Menu 3.3.1 Set Clock 3.3.2 Optional Languages 3.3.3 Speaker Volume 3.3.4 ISO 1/3 En/Disable 3.3.5 Change Passwords 3.3.6 Device Setup 3.3.7 Set Reboot Time 3.3.8 Serial Number 3.4 Customer Setup Menu 3.4.1 Change Message 3.4.2 BIN Lists 3.4.3 Optional Features 3.4.4 Change Processor 3.4.5 Surcharge Mode 3.4.6 Graphics
4. OPERATION 4.1 Opening and Closing 4.1.1 Opening the Security Door 4.1.2 Closing the Security Door 4.1.3 Opening the top Bezel 4.1.4 Closing the top Bezel 4.1.5 Operating and Changing the Combination Lock 4.1.6 Operating and Changing the Electronic Lock 4.2 Cash Operations 4.2.1 Adding Cash to the Cassette (TCDU) 4.2.2 Emptying the Reject Bin (TCDU) 4.2.3 Adding Cash to the Cassette (MCDU) 4.2.4 Emptying the Reject Bin (MCDU) 4.2.5 Loading the Receipt Printer 4.3 Settlement Menu 4.4 Journal Menu 4.5 Reports Menu
APPENDIX A. Error Codes B. Clear NVRAM C. Master Key installation D. Custom Screen Graphics
Introduction Operator Manual
G1900 Genmega 2011 1.1 FEATURES
1.1.1 The Genmega G1900
Introducing the Genmega G1900 series retail ATM. Designed and engineered to meet the needs of the highly competitive retail ATM market, this innovative machine combines all the features you expect, built on a flexible platform allowing you to custom fit each machine to its location and traffic volume.
Packed with features like a 7 high-resolution LCD screen, ready for your custom advertisements and a reliable dual-head swipe card reader (upgradable to DIP and EMV). The G1900 Series vault has been reinforced along the door edge, and a flashing security LED added to help prevent physical attacks.
In addition to the dispensing options offered by Genmega, including drawer, cassette, and multi-cassette devices, the Genmega G1900 series supports several other popular dispenser models including the De La Rue SDD and the Puloon LCDM1000 providing an economical upgrade for existing machines
H/W FEATURES
UL 291 Business Hour Service Vault featuring reinforced steel bottom & dial lock 7 high-resolution, wide-screen TFT LCD 56K modem + Ethernet TCP/IP with SSL encryption 800 note fixed cassette dispenser (TCDU) 1000 note removable cassette dispenser (SCDU) 1700 note removable cassette dispenser (MCDU) Dual Cassette 3400 note (1700x2) dispenser Dual Head Swipe-type magnetic card reader (EMV Optional) 2 Thermal receipt printer Modular design for easy maintenance Lighted transaction guidance system Meets ADA Standards for Height, Reach and Keypad layout
FUNCTIONAL FEATURES
Electronic journal stores over 40,000 transactions Supports English, Spanish and French languages Availability for 8 on screen advertisement graphics Detailed average history report feature On-screen error code descriptions for easy service Introduction Operator Manual
1. LCD & Customer Keypad 11. Security Door Handle 2. Card Reader Slot 12. Cash Dispensing Unit 3. Receipt Printer Slot 13. Receipt Printer 4. Cash Tray 14. Main Control Board 5. Front Panel 15. Ear Phone Jack 6. Front Panel Lock 16. Power Supply 7. Security Cover 17. Speaker. 8. Security Cover Lock 9. Security Door 10. Combination Lock Introduction Operator Manual
G1900 Genmega 2011 1.4
1.2.2 Front Panel Identification
Fig. 3 Front Panel Identification LCD Screen Size: 7 TFT LCD Resolution: 800 x 480 WVGA Display Characters: 40 x 15 (Standard Characters) 8 LCD Function Keys
KEYPAD Certified VISA compliant EPP (Encrypting Pin Pad)
Voice Guidance Port Voice assisted operation available through the headphone jack on the front bezel EPP Keypad Receipt Printer Voice Guidance Lighted Topper Function Keys Dual-Head Swipe Card Reader Lighted Transaction Guidance LCD Panel Introduction Operator Manual
G1900 Genmega 2011 1.5 1.2.3 Cash Dispensing Unit
Cash Dispensing Unit (1000 Note - SCDU)
CASH DISPENSING UNIT
Dispensing Speed: 2.5 notes/second Capacity of 800 new notes (fixed cassette) Capacity of 1000 or 1700 notes (removable) Lockable Reject Bin Double note detect module
Thermal line printer 36 characters/line Semi-automatic roll paper setting Motorized front push rollers
PAPER SPECIFICATIONS
One sided thermal paper Factory paper is thermal side out (but either way will work) 6 inch outside diameter roll 2 inch wide Core inside diameter 11/16 inch 21# weight (paper thickness) Introduction Operator Manual
G1900 Genmega 2011 1.7 1.2.5 Main Control Board
Samsung S3C2440AL-40 RISC 32-bit CPU 64 MB RAM WinCE 5.0 Operating System Modem: 56,000 bps dial-up modem TCP/IP Ethernet connection - Onboard SSL Electronic Journal: 40,000 transactions Battery back-up for set-up parameters (NVRAM) Real time clock
1.2.6 Operating Environment
POWER REQUIREMENTS
110/220 VAC 10%, 50/60 Hz, 145 Watts
POWER CONNECTIONS
For warranty purposes, Genmega requires the 1900 series ATM be connected to a dedicated power circuit (5amp recommended). This circuit must consist of line, neutral, and ground leads connected directly to the power circuit breaker panel. This circuit should not be shared with any other equipment. Use of a surge protector or uninterruptible power supply is recommended.
PHONE LINE REQUIREMENTS
The Genmega G1900 must be connected to a dedicated analog phone line. This line must be a direct-dial analog line. It is important to disable any voice-mail included on that phone line as it will cause the ATM not to dial out. This line should not be shared with any other equipment at the location. Use of shielded (CAT5) phone cable is also recommended for best performance and to reduce the chance of interference. Digital phone lines are NOT supported.
NETWORK (TCP/IP) REQUIREMENTS
For connection to processor via TCP/IP, use an Ethernet Patch-Cable (not included). The ATM must connect to a device (Router) that can provide DHCP support unless a static IP address is assigned by the service provider. It is recommended the ATM connect to a broadband router (Linksys, Netgear, Belkin) or similar device rather than directly to a Cable/DSL modem. For advanced or corporate networks, provide the IT staff with ATM Host IP address and Host Port information (available from your ISO).
TEMPERATURE
In storage : 32F - 123F (0C 49C) While operating : 40F - 95F (5C 35C)
Genmega, Inc. provides a limited one-year parts warranty for the G1900 series ATM. Genmega guarantees your G1900 model ATM to be free from defects in materials and workmanship.
The one-year parts warranty will begin 15 days from the shipping date.
WHAT IS COVERED: Cash Dispensing Unit (CDU) and Cash Cassette Receipt printer (SHU) LCD module Magnetic Card Reader (MCR) EPP Keypad Power Supply Mainboard (CE) Lock and locking mechanism **LIMITED 90 DAY WARRANTY** Dial and Electronic locks will be covered by a limited 90-day warranty beginning 15 days from shipping date. Should the lock fail under normal use, Genmega will replace the lock only. Services required to open the vault and or replace the lock are at the expense of the ATM owner.
WHAT IS NOT COVERED: Power cable and modem cable Key lock and key Plastic Bezels Software upgrade Receipt printer jam Note jam Forgotten password or combination of lock Any damages from misuse, improper installation, and vandalism Any damages from brown out or low power, lightning, or any other acts of God
Your distributor/dealer may offer an enhanced or extended warranty in addition to the original manufacturers one-year warranty. Once the manufacturers warranty has expired, all claims for warranty service must be resolved directly between the distributor/dealer and the ATM owner.
OBTAINING SERVICE: If you have any problems or questions about your Genmega ATM, your dealer or distributor is your primary contact for assistance/service. Your manufacturers warranty is provided through your dealer or distributor.
Section 2: Installation Operator Manual
G1900 Genmega 2011 2.1 INSTALLATION
2.1 Genmega G1900 INSTALLATION
2.1.1 UNPACKING
Step 1
Upon receipt of your new Genmega ATM, check the box and packaging for any damage. If you suspect any damage, mark the shipping receipt to indicate suspected concealed damage. Do not discard the ATM packaging materials until you have verified any shipping damage claim. Contact your distributor immediately if you see any shipping damage. Its also advisable to take photos of any damage.
NOTE: You have 7 days from delivery to report any concealed damage. After 7 days we are unable to process any shipping damage claims.
Step 2
Verify the contents carefully with the packing list to make sure all items listed are included per your order. Notify your distributor of any shortages.
2.1.2 PHYSICAL INSTALLATION
To install the Genmega G1900 ATM, review the following steps:
Step 1
Place the system on a flat surface during installation. The system is top-heavy and has a tendency to tip over. Be very careful when opening the top or bottom slide trays or vault door prior to bolting down the ATM, it will be more likely to tip.
Step 2
Use the holes in the bottom of the vault to mark the floor or ATM location. Remove the ATM before drilling the anchor holes. Anchors are not included with the ATM.
WARNING: Do not drill the holes through the vault. Dust from the drilling will damage ATM components and void your warranty.
Due to variations in flooring and building codes, Genmega does not recommend a particular size or type of anchor as each installation. Consult anchor manufacturers instructions for proper installation. Maximum anchor diameter is .
Step 3
Place the G1900 ATM on top of the anchors and tighten. Note that over-tightening the anchors can cause the vault to go out of square and make door operation difficult. If this occurs, back off the anchors or use leveling bolts. Section 2: Installation Operator Manual
G1900 Genmega 2011 2.2
Step 4
Open the vault door bezel with the key provided. See page 4.1 for Opening and Closing instructions.
Step 5
Using the supplied combination (see lock manual for default combination), open the Vault door. The default combination should be changed as soon as possible. Refer to page 4.5 (dial) or 4.7 (electronic) for instructions on opening or changing the lock.
2.1.3 HARDWARE SETUP
Step 1
Verify the incoming power voltage (115/220V) for your location and check the switch on the power supply of the ATM (should be defaulted to 115V)
Step 2
Verify that the telephone line or internet connection for the ATM is in proper working order. Make sure there is no voicemail on the line (pulse noise when you first lift the receiver). NOTE Digital phones lines are not supported by this ATM.
Step 3
Open the security door. See page 4.1 for assistance.
Use this key (2 included) to open the top and bottom bezels Cassette key (fixed cassette) Cassette key (removable cassette) Section 2: Installation Operator Manual
G1900 Genmega 2011 2.3 Step 4
Remove the cash cassette from its packing box (removable cassette dispensers only). Fill the cassette or cash drawer with the appropriate amount of notes, and carefully place it in the Cash Dispensing Unit. Place the appropriate denomination label on the front of the cassette. See page 4.9 for instruction.
Step 5
Before closing the vault, thoroughly test the combination lock by locking and unlocking the lock several times. It is much easier to diagnose potential lock problems before shutting the door.
Step 6
Open the top of the ATM. Place the receipt paper in the Receipt Printer. The paper prints only on one side (shiny side) always check the roll when you install paper. Place the roll so that the coated side (shiny side) will be facing up. See page 4.12 for paper loading instruction.
Step 7
Connect the Power cable and the telephone cable to the appropriate outlets on the wall. Verify that the AC power outlet is grounded (3 prong plug).
If you are installing an optional topper sign, install the power cord through the top housing and plug the topper into the open connector (white) located on the back of the slide tray. Make sure the cable has enough slack to allow the slide tray to open completely.
Step 8
Turn the power on and verify that all systems are operational. If any part on the system or its programming is not operational, an error code will be displayed along with instructions. If the error cannot be corrected, please contact your distributor for help. If no error code is displayed, check the Error Summary.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.1 PROGRAMMING
3.1 INITIAL SETUP
3.1.1 ACCESSING THE OPERATOR FUNCTION
To access the Operator Menu, you do not need to hold down the 3 keys (CANCEL, CLEAR, ENTER) and then press 1 2 3. Just press the following keys in order [ENTER] [CLEAR] [CANCEL] [1] [2] [3].
Note: The Operator Function menu can only be accessed when the machine is either in service (insert your card screen) or out of service. If the machine is attempting to connect to the host or initializing, you will not be able to use the key commands to access the Operator Function Menu.
If you have difficulty accessing the Operator Menu, power off the ATM and then either open the vault door or remove the paper from the printer and power back on. This will force the ATM to the Operator Menu.
Once you successfully completed the key combination, you will be prompted to enter a password. There are 3 levels of passwords.
Operator Password (allows access to basic menu structure) Service Password (allows access to basic and diagnostic menus) Master Password (allows access to all menus including setup parameters)
You must press ENTER key after typing the password!
Passwords are very important to maintaining security for your ATM. Your dealer/distributor will provide you with default password information.
WARNING: Genmega highly recommends changing your passwords from default as soon as possible. Keep all passwords safe and restrict access to non-authorized personnel.
Passwords MUST be 6 digits in length, use of anything other than a 6 digit password may cause the passwords to revert back to factory default. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.2
Shown the left is the complete Operator Function menu, depending on which password you entered (operators, service, master) you may not see certain functions. For example, if you use an operator password you will not see the Host Setup button, as you will not have access to that menu.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.3 3.1.2 WHEN AN ERROR OCCURS
Step 1
When an error occurs, please press [ENTER] [CLEAR] [CANCEL] [1] [2] [3].
NOTE: If the machine goes out of service, the error code will not always appear on the screen. If you do not see an error code, enter operator function and go to reports. Look in the error summary for error codes.
Step 2
ENTER PASSWORD will be displayed. Enter the Master, Service or Operator Password to continue.
Contact your distributor for default passwords.
Remember to press ENTER key after typing password!
Step 3
When the screen is in current display, press OP key to access the OPERATOR FUNCTION.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.4 3.1.3 EPP KEYPAD
Genmega G1900 LCD display Function Key layout
This keypad layout and table below will help while learning how to input text and numbers while programming your Genmega ATM. When in a text entry screen, the F1, F3 and F5 keys are used to switch character maps between upper and lower case as well as special characters.
0 1 2 3 4 5 6 7 8 9 + Space A D G J M P T W - Q B E H K N R U X F1 Alphabet Upper = Z C F I L O S V Y + Space a d g j m p t w - q b e h k n r u x F3 Alphabet Lower = z c f i l o s v y 0 1 2 3 4 5 6 7 8 9 ( [ { < , ! % : ? F5 Number Special ) ] } > . $ * ; / Section 3: Programming Operator Manual
G1900 Genmega 2011 3.5 3.2 HOST SETUP
The Host Setup menu provides access to the parameters necessary to connect the ATM to the processor. Master Password is required to access most of these options; however Service password allows basic access for troubleshooting purposes.
3.2.1 KEY MANAGEMENT
Access to Key Management requires entering a Secure Mode which engages additional security measures (per VISA specification) to prevent Master Key tampering. Make note of these changes as it does affect how keys are entered.
Entering Key Management requires two 6-digit passwords. By default these will be 000000 for part #1 and 000000 for part #2.
If a mistake is made entering the Secure Mode password, you will be prompted to wait 30 seconds to reattempt.
NOTE: In compliance with PCI specifications, you must change the Secure Mode Passwords from default before any Master Keys can be entered. After changing the Secure Mode Passwords, you must exit completely from the Operator Menu, and reboot the machine. After this step, you can enter Master Keys. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.6 Successful entry of both passwords will grant access to the Key Management screen. From the moment the Key Management area is entered, a 5 minute timer begins. At the end of 5 minutes, regardless of what you are doing (entering a master key for example) the Key Management area times out and you will be taken back to the Host Setup menu.
KEY MODE This option sets the type of master key you will be loading (TDES, DES, MAC etc.) Refer to Addendum C for Key Mode descriptions and instructions.
MASTER KEY INDEX The ATM will hold up to 16 individual Master Keys. Check with your processor to find if they are expected to be at a certain location. For example Coredata is always installed at index #9, most other processors are installed at index #0 or #1. The ATM will only use the key that the index is set to regardless of how many keys are installed. To set the index simply press the button labeled Master Key Index and then enter the number you want it set to (enter as a 2 digit number ... 00, 01, 02, 10, 11 etc.) press Enter when done. Press Check Master Key to see a list of currently installed keys.
CHECK MASTER KEY This will show the list of available master keys and their appropriate checksums. The checksum is a 4 digit number calculated from the two 16-digit numbers of your master key that provides a means to verify the master key is correct. When your processor provides your Master Keys, they will also give you the 4 digit checksum. If after entering your Master Key this checksum does not match, try reentering your master keys or contact the processor.
EDIT MASTER KEY This is where you enter your two 16-digit Master Keys (provided by your processor). After pressing Edit Master Key, you will be prompted to enter an index where you want this key stored. If you do not know which index to use, contact your dealer or processor. Generally, you should use index 0 or 1 unless otherwise instructed.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.7 CHANGE PASSWORD This allows you to set each part of the Secure Mode Password. As with the other passwords used in the G1900, each must be a 6 digit number. If you change the password and cannot remember it, you must clear RAM on the pin pad to reset.
NOTE: In compliance with PCI specifications, you must change the Secure Mode Passwords from default before any Master Keys can be entered. After changing the Secure Mode Passwords, you must exit completely from the Operator Menu, and reboot the machine. After this step, you can enter Master Keys.
Entering Master Keys: Use the chart below for entering Master Keys from the main pin pad. Master Keys (or Key Management) cannot be entered from the optional Rear Service Panel. Please see Appendix for specific Master Key instructions.
NOTE: The keypad above is EPP-B1 PCI / Interac certified EPP Device. Previous models of EPP (PCI Only) had the Enter and Cancel keys reversed from what is displayed above. If entering keys on the PCI only keypad, remember that the Enter key is always F and the Cancel key is always D.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.8 3.2.2 SET TERMINAL ID NUMBER
Step 1 From the Host Setup Menu, go to Terminal ID. Terminal ID number is provided by the processor and is individual for your ATM. It identifies your ATM on the network and any transactions done on your machine will be linked to that number. This number is obtained either through your dealer or processing company.
3.2.3 CONNECT TIMER
The connect timer is the setting which determines how long the machine will wait to connect when trying to dial into the processor. Default time is 60 seconds. Lowering this may improve connection speeds but at the risk of reliability.
3.2.4 SET ROUTING ID NUMBER
From the Host Setup Menu, go to Routing ID. The Routing ID is unique to each processor and identifies the machine by processor. This number is obtained either through your dealer or processing company.
NOTE: If using Standard 3 (Extended Messaging) Routing ID becomes COMS ID
3.2.5 SET HOST TELEPHONE NUMBER
Step 1 From the Host Setup Menu, go to Telephone Number.
Step 2 You can enter a Primary (Host Phone 1) and a Secondary (Host Phone 2) for the machine to connect to the processor. These phone numbers are available from your dealer or the processor (you can also reference the quick installation guide enclosed with this ATM for numbers for the common processors).
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.9 Step 3 Once you have selected Host Phone #1 or Host Phone #2 you will be prompted with the following screen. Using the numbers on the keypad press the first number of your phone number.
Step 4 Genmega always recommends using a dedicated, data-quality phone line for all ATM installations, however if you are using a phone line that is dialing out through a PBX type system (where you dial a number for an outside line), then you may insert commas ( , ) to create a pause between digits.
For example if you have to dial a 9 to get an outside line try the following: 9,,18005551212 (the 800 number being an example)
NOTE: Entering anything other than a number or a comma in the host phone number field will cause the ATM not to dial out. Make sure that Zeros and Os are identified properly.
END
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.10 3.2.6 HEALTH CHECK MESSAGE
Health Check is an option that will send a system status signal to your processor at a set interval. Check with your dealer or processor to determine if they are prepared to receive this type of messaging.
To Enable, simply access the menu from Host Setup. Use the Host Send button to enable or disable the feature and the Message Send Interval button to set how often the machine will broadcast its status (in hours).
NOTE: When using Standard 1 processing mode, an option for Extended Health Check will appear. This option is for 4 cassette dispensers and is not used in the G1900
3.2.7 REMOTE MONITOR
Remote Monitoring is the ability to dial into your ATM and send or retrieve information using Genmega Remote Management Software (RMS).
RMS EN/DISABLE This will allow the ATM to be monitored remotely.
Enable The ATM will answer incoming RMS calls. Disable The ATM will not answer any incoming calls.
RMS SEND This feature causes the ATM to dial out to a computer running RMS software to report a malfunction, a fatal error or an out of service condition. Any time the ATM goes out of service for longer than 3 minutes, it will call the number programmed at Remote Phone #1 (and then Remote Phone #2 if Remote #1 is busy). It will attempt this call 3 times. In order to use this feature you MUST have a PC (with a modem and a dedicated phone line) running RMS software available 24 hours a day.
Enable The ATM will dial out to report out of service condition. Disable The ATM will NOT dial out to report out of service condition.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.11
RMS PASSWORD Remote monitoring is protected by a password that is checked when incoming calls from RMS occur. If the password does not match from an incoming RMS call, the call will be disconnected. The default password for RMS access is 333333. To change the password, press the password button and you will be prompted to enter your Master password. After entering your Master password, you will be prompted to enter the new RMS password (must be 6 digits) and then enter it again for verification. If you ever forget the RMS password, press password and follow the procedure again.
REMOTE PHONE #1, #2
This is the number the ATM will call if there is an out of service condition. Press the button for either number and enter the number for the computer you want the ATM to call.
Using the numbers on the keypad press the first number of your phone number. You can use the <, > keys on the keypad to move back and forth (to correct any mistakes, or edit existing numbers).
RING COUNT This setting determines how many rings will elapse before the ATM will answer the phone. While this can be used in situations where the ATM phone line is shared with an additional device (like a fax or business phone) its important to note that setting this value higher than 4 or 5 may result in monitoring software being unable to connect.
3.2.8 TRIAL DAY TOTAL
Trial Day Total feature allows the ATM to complete a Day Total operation (without actually closing out the machine) at a predetermined time each day. This is useful if you are doing accounting of your ATM on a day-to-day basis. Your processor cuts off its transactions each day at a set time. By enabling Trial Day Total at the same time, your days balance should match the host. This information will appear as a journal record, so you will need to access your journal to print or view the totals. Your dealer or processor can provide you with the appropriate cut off time.
Trial Day Total Set Enables or Disables the function Change Time Sets the time for the ATM to total itself
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.12 3.3 THE SYSTEM SETUP MENU
3.3.1 SET CLOCK
The Set Clock menu allows you to set the clock built into the ATM to the appropriate date and time. You should set this for local time in the area the machine is to be installed. Note that with each transaction you will see also see a Host time, this is the local time for the processor and may be different from local time at the ATM. To set the clock, simply press the Set Clock button and press the key corresponding to the function you want to set (month, day, year, etc.)
NOTE: The ATM will not automatically adjust for daylight savings time. You must set this manually if you wish it to change.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.13 3.3.2 OPTIONAL LANGUAGES
The Genmega G1900 ATM supports 3 on screen languages: English, French & Spanish. The optional languages will display on the welcome screen, then the customer will be prompted to choose a language to be used for the rest of that transaction.
NOTE: The optional languages are displayed on screen only and do not print on the receipt or journal. Receipts, journals and operator menus are always in English. To enable or disable a language, simply press the button next to the language you wish to change.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.14 3.3.4 ISO 1, 3 EN/DISABLE
The ISO Tracks are the three tracks available for the card swipe head to read. The ATM is already defaulted to read from Track #2 (which is why its not shown). This parameter should not be changed. Changing the ISO tracks can cause the ATM to not read cards properly.
3.3.5 CHANGE PASSWORDS
The ATM uses three passwords to provide security to the operator menu system. These are Operator, Service and Master.
Operator Password (allows access to basic menu structure) Service Password (allows access to basic and diagnostic menus) Master Password (allows access to all menus including setup parameters)
The operator password can be changed by anyone with the current operator password. The service and operator passwords can be changed by anyone with the service password. The master password can only be changed by someone with the current master password. Any password can be changed using the master password.
For example, if you have lost the operator or service password, you can use your master password to change them. Simply enter the master password when it requests the operator or service password and then enter the new password.
You are required to change the master password from default before the ATM can go in service. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.15
To change a password, press the button for the appropriate password. You will be prompted to enter the new password and then enter it a second time to verify. If you forget your password please contact your dealer or distributor for service.
NOTE: All passwords MUST be 6 digits. If you use a password that is less than 6 digits, the passwords may default back to factory if the machine is power cycled. If your customer wants a 4 or 5 digit password, add zeros to the end to make it 6 digits.
WARNING: The ATM will NOT go into service with the default master password. You must change the master password from default! If you attempt to go in service with the default master password, you will receive a F0016 Error, which will notify you that the master password has not been changed.
It is critical that you do not set the same password for each of the three levels. If you duplicate the password, the lower level permissions will be the default. For example, if the Operator Password is set to 123456 and you also set the Master Password to 123456, then when you log in with that password, youll only have access to Operator level commands. In this example, youd have to change the Operator Password to something else, and then 123456 would then allow you to log in as Master. If you forget the passwords, youll need to reload the AP software to reset. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.16 3.3.6 DEVICE SETUP
The Device Setup menu provides options to adjust parameters of the various peripherals. Under normal circumstances you should not need to make changes to these parameters. The default settings are optimized for your particular machine. Genmega recommends only using these tools under the direction of an Authorized Service Provider (ASP) or Genmega Technical Support.
3.3.6.1 SPR SETUP
The SPR Setup allows you to set the maximum column width for the receipt printer. Default is 40 characters.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.17 3.3.6.2 MODEM SETUP
The Genmega G1900 series use an onboard 56K modem. The modem is preset at the factory for optimal use. Changing these settings can cause your machine to not communicate or may slow communication speeds. Do not make changes to the modem settings.
MODEM SPEED This sets the speed at which the modem will begin communication with the host. The default speed is 2400. Most processors are only using 2400 baud modems, so setting this value higher may not increase modem performance.
Available settings : 1200, 2400
MODEM SOUND This will allow the modem to output its dial-out and handshaking through the external speaker. This is useful when testing the modem to hear if its dialing properly.
Available setting: OFF , ON
3.3.6.3 MCR (Card Reader) SETUP
The Genmega G1900 can be equipped with an optional EMV compliant card reader. If the setting is not correct, the card reader will not work at all. After setting the MCR to the appropriate type reader, back out of the menus and then reboot the machine for the changes to take effect. Since these different card readers use alternate ways to communicate, its necessary to reboot. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.18 3.3.6.4 CDU SETUP
The CDU (Cash Dispensing Unit) or Dispenser contains programming relative to its application and country of destination. This programming does not need to be altered, however in the event that the dispenser looses its factory programming the CDU Setup application can correct any problems. NOTE: Incorrect programming of the dispenser will cause the machine to go out of service.
3.3.7 SET REBOOT TIME
The G1900 contains a feature which automatically reboots the machine at a 24 hour interval. By default this will occur at 03:00 am. This adjustable in 1 hour increments.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.19 3.3.8 SERIAL NUMBER
The serial number is a unique number programmed into your machine at Genmega. It not only identifies your machine for warranty purposes, but also for remote monitoring using Genmega RMS. The first 4 digits refer to the model type, and the last 6 is production cycle. By default this number is programmed from the factory and we do not recommend changing it. However if you need to clear NVRAM for any purpose this number will be deleted. If you wish to re-enter the serial number, youll find it on the sticker located inside of the upper cabinet.
Keeping the serial number in the proper format will prevent problems when trying to connect for remote management.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.20 3.4 CUSTOMER SETUP MENU
The Customer Setup menu controls surcharge information, BIN lists, receipt options, advertisements and keypad lighting.
3.4.1 CHANGE MESSAGE
The Messaging options for the ATM are a welcome message and a receipt header message. The Welcome message allows line of 35 characters, which will appear at the top of the main screen (above the center graphic). The receipt header is up to 4 lines of 25 characters, which will appear at the top of each receipt.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.21
WELCOME MESSAGE
Once you have selected Welcome Message from the Change Message Menu, you will be prompted with the following screen.
RECEIPT HEADER
Once you have selected Receipt Header from the Change Message Menu, you will be prompted with the following screen. See the above instructions for navigating this menu.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.22 3.4.2 BIN LISTS
BIN numbers are card numbers that you have preset with your processor to not be surcharged. You must set this up with your processor, who will then give you numbers to enter in the list. These numbers will reference cards that you wish to not be charged a surcharge for transactions. The ATM will hold up to 96 numbers (0- 95).
If you need more BIN numbers, there is a file that can be created to load several thousand more numbers. See Appendix for instructions.
Step 1
To enter the BIN numbers select BIN List from the Customer Setup menu. The list can hold 2 banks of 30 numbers for a total of 60. Bank 0 and Bank 1. Press the OTHER button to switch between the banks.
Step 2
To add a number, press ADD and input the BIN number with the keypad. To remove, press REMOVE and type in the BIN number you wish to delete from the list.
Press OTHER to switch between Bank 0 and Bank 1. Step 3 If you wish to view the contents of the BIN list, use the Print All Setup report. From the Operator Function Menu, go to Reports, then Print All Setup. Any numbers added to the BIN list will be visible from this report. NOTE: Numbers loaded via the extra BIN file will not display on the Print Setup or any other report.
END
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.23 3.4.3 OPTIONAL FEATURES
The G1900 ATM offers several optional functions to improve performance and keep the ATM functional in the event of a paper problem (jam, out of paper etc.)
LOCATION NAME Adding a name to this location will print the name entered onto the journal records and print all setup. This is purely a convenience option and is not required.
SELECT RECEIPT This feature allows the ATM to complete transactions even though it may not be able to dispense a receipt. If the ATM experiences a paper jam, or runs out of paper, the customer will be asked if they would like to complete the transaction even though they will not receive a receipt. If the customer answers Yes, the transaction will continue. Following the transaction the customers information (what would have appeared on the receipt) will display on the screen. The ATM will continue to operate without use of the printer until someone accesses the Operator Function menu. At that time the error must be corrected before the ATM will go back into service.
To enable the option, press Select Receipt, the lower portion of the screen will display the options status. TRANSFER TO CREDIT Some networks do not allow customers to transfer funds to or from their credit cards. By enabling / disabling this option you will add or remove the option button from the customer menus. Check with your Distributor / Processor as to whether or not they support fund transfer to or from credit cards. NOTE: If your network does not support such transfers and you leave the option enabled, the customer can choose it from the menu however the network will not authorize the transaction.
CHECK BALANCE Enabling this option will ask each customer if they would like to check their balance before each transaction.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.24 3.4.4 CHANGE PROCESSOR
Host Processor selection changes the communications protocol to specifically match your particular processor. In most cases this is set at the factory when your machine is ordered, however in the event that the machine needs to be reprogrammed for a new processor, it may be necessary to change the processor mode.
NOTE: You do NOT need to clear NVRAM to access the Change Processor menu
To access the Host Processor mode, enter the Customer Setup menu using the Master Password.
Communication modes are:
Modem dial up (uses on board modem)
TCP/IP Standard TCP/IP VISA FRAME TCPIP ACK CONTROLLED TCPIP SSL PASS THROUGH SSL LENGTH PREFIX W/O ETX SSL LENGTH PREFIX WITH ETX
** See page 3.31 for TCP/IP Setup Instructions **
Use the Message Format button to select the appropriate Host Processing Mode. Available formats are:
Standard 1 Standard 2 (CSP200 Emulation) Standard 3 (Extended Message) EPS
If Standard 3 is selected, youll see a Standard 3 Options button which will give access to the Extended Messaging options.
Contact your distributor or processor for which mode is appropriate. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.25 3.4.5 SURCHARGE MODE
The Surcharge menu displays the current rate at which customers are charged per transaction, the person or account that the surcharge funds are sent to and whether or not the option to surcharge is enabled or disabled. The information programmed here must match the information given to the processor at the time the account was created. Because of features like Percentage Surcharge that require the surcharge value to be set at the ATM, its possible for the ATM to override what the processor expects to surcharge (or not surcharge customers at all) if these settings are not correct.
Please review the following setting carefully and instruct your operators on the risks involved in changing surcharge settings.
To set the surcharge parameters begin by entering the Surcharge Mode menu from the Customer Setup menu. The bottom of the screen displays the current status of each surcharge parameter.
DISABLE/ENABLE This button toggles the surcharge option on and off.
AMOUNT To set the surcharge amount, press the amount button and type the dollar amount using the main keypad. Next set the decimal point using the Enter key on the keypad. Then type the cents using the keypad and finally press Enter to finish.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.26 PERCENT This allows you to set the surcharge amount as a percentage of the overall amount the customer is withdrawing per transaction. Check with your processor to make sure that they support this function.
SURCHARGE OWNER
The surcharge owner can be up to 25 characters long. This owner name will appear at the bottom of each transaction receipt.
WARNING: If you set the percentage surcharge mode from Greater to Lesser and leave the percentage value at 0%, then customers will not be surcharged.
Example - Surcharge set as follows:
Surcharge $1.50 or 0% whichever is Greater = customer is charged $1.50. Because $1.50 is a greater value than 0.
Surcharge $1.50 or 0% whichever is Lesser = customer is not charged at all. 0% is lesser than $1.50.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.27 3.4.6 GRAPHICS
The Genmega G1900 is capable of displaying up to 8 customized graphic screens. These graphic files are created on a computer and then downloaded into the ATM either directly at the ATM using a SDRAM card or by using the Genmega Remote Management Software (RMS). When the advertisements are loaded and enabled they will rotate in order while the ATM is waiting for a transaction and also while the transaction is processing. There is a timer, which allows you to set a delay before switching to the next graphic screen. Please see Appendix D at the end of this manual for detailed instructions for creating advertisements.
Step 1
Enter the Graphics menu and choose Advertise enable or disable each loaded graphic.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.28 3.5 TRANSACTION SETUP
3.5.1 DISPENSE LIMIT
The dispense limit is the maximum amount of money a customer can withdraw in a single transaction. The ATM will dispense a maximum of 40 notes per transaction. So the dispense limit can be a maximum of 40 times the denomination of notes your using.
For example:
If you are dispensing $10 bills the maximum dispense limit is $400 If you are dispensing $20 bills the maximum dispense limit is $800 Maximum is $900 (using either $50 or $100 bills)
To set the dispense limit, press the Dispense limit button and then enter the number using the keys on the main keypad. Press Enter key to set the value.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.29 3.5.2 DENOMINATION
The Denomination is the type of bill that each cassette will be dispensing. The ATM offers a second cassette as an option. This second cassette can be programmed to dispense notes, it can also dispense a preset number of bill sized coupons with each transaction and finally it can dispense a value coupon, where you would set the value of the coupon and the customer could purchase this using their card.
WARNING: Any change to the denomination will cause all master keys to be deleted from the EPP keypad. If you attempt to enter the denomination setup menu, you will be prompted and warned that continuing will cause all master keys to be erased. The purpose of this is to prevent unauthorized changes to this critical setting.
When programming the ATM, make sure to make any changes to the denomination setting BEFORE you program master keys. Once keys are erased, they cannot be recovered. New master keys will have to be loaded.
To set denomination on the first cassette, press the First CST Denomination button and then using the main keypad enter the type of bill. Options are $1, $5, $10, $50 and $100.
To set denomination on the second cassette, press the Second CST Denomination button and then using the main keypad enter the type of bill. Options are $1, $5, $10, $50 and $100.
When programming the ATM, make sure to make any changes to the denomination setting BEFORE you program master keys.
Once keys are erased, they cannot be recovered. New master keys will have to be loaded. Section 3: Programming Operator Manual
G1900 Genmega 2011 3.30 3.5.3 FAST CASH
Fast Cash amounts are presented to the customer if they choose a Withdrawal transaction. These amounts appear on screen as an easy method of selecting how much cash they wish to withdraw for that transaction. The amounts must be multipliers of the denomination amount.
For Example:
If your dispensing $10 bills then you can use $10, $20, $30, $40, $50 etc. If your dispensing $20 bills then you can use $20, $40, $60, $80, $100 etc.
To set the fast cash amounts, select Fast cash from the Transaction Setup menu and then choose from the 6 possible keys to program. Select a button and then enter the value from the main keypad. Press Enter to confirm the setting.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.31 3.6 TCP/IP SETUP
TCP/IP Setup is done in several menus. First you need to specify TCPIP from the Communications Menu: [See page 3.24] Check with your processor for which protocol they are expecting.
Operator Function Menu Customer Setup Change Processor Communication Change this value to SSL Pass Through (or other depending on processor)
Once you change from Modem, to one of the TCP/IP settings, several other menus change to support various network functions.
For Example: Operator Function Menu Host Setup Processor IP and Address Port
Here you will set the Host Processor IP (or URL) address and port. For some processors an IP address (example = 121.212.1.21) is used and for others youll enter a URL address (example = trans.mybank.processor).
In addition to the address, there will also be a port setting (example = 6543)
Configuration Schedule allows you to force the ATM to update configuration with the host upon boot up. You might use this command if the terminal gets consistent Key Errors and you want to force download of a new working key.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.32 The ATM IP information is set using the menu found at:
Operator Function Menu System Setup Device Setup ATM TCP Setup
This menu is only active if you have the communication mode set to TCP [See page 3.24]
These settings will be dependant on the network connection available at the location where the ATM is deployed. It may be necessary to contact the ISP or Network provider for the location to determine how this should be set.
TCPIP Mode: DHCP or STATIC IP
NOTE: a Static IP address will be required if you intend to use RMS monitoring software with this ATM.
Change IP Address: Enter the ATM IP address here (for static IP) or this field will automatically populate if DHCP is used to obtain an IP automatically.
Subnet Mask and Gateway: These values will be provided by your ISP/Network Provider and refer to the Router that youll be connecting to.
Ping to Gateway: This is a test which will ping the Router and verify communication between the ATM and the network. If this test fails, then the ATM will not reach the host.
Ping to Host: This test attempts to verify communication with the IP address or URL that is programmed in the Processor IP Address menu. Note that most processors or switches do not allow pinging for security reasons.
Section 3: Programming Operator Manual
G1900 Genmega 2011 3.33 TCPIP Troubleshooting
When trying to connect your ATM to the internet, there are two error codes which can occur.
2511 This means that the ATM sent a request, however nothing responded. Typically this means the ATM cannot get out on the internet.
To test this, we suggest replacing the Host IP number with one from a common public website like Google [74.125.224.50] or Yahoo [98.137.149.56] Those IP addresses will allow pinging. So after entering it, you can go to the Ping to Host button in the TCPIP setup menu and check that you can ping google or yahoo.
If you are unable to ping those sites, the ATM cannot see the internet.
DSL Modems some cheap DSL modems will not allow the ATM to use DHCP and obtain an IP address, even though other computers or devices can. This is usually shown in the ATM TCPIP Setup Menu, where the Gateway value is 0.0.0.0. If this occurs, you will need to get a broadband router to place in between the ATM and the DSL modem. This will allow the ATM to get an IP address from the router, rather than the DSL modem.
2514 This means that the ATM sent a message and received an unexpected or incorrect response. Typically this means that one or more settings on the ATM are incorrect and should be compared against what the processor is expecting.
Network Cable:
When you connect the internet (Ethernet) cable to the ATM you should see a steady link-light (green) on the and also a flashing data-light (amber) as shown below.
Make sure you use a network patch cable and not a cross-over cable.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.1 OPERATION
4.1 OPENING AND CLOSING
4.1.1 Opening the Security Door Step 1
Turn the vault bezel key clockwise to open the lower vault bezel. The key will remain in the lock after you turn it.
Step 2
To unlock the Dial or optional Electronic Lock (see the manufacturers lock manual included in the open me first box for default combination) and then refer to Section 4.1.6 for lock instructions
Step 3
Turn the security Door Handle counter- clockwise; then pull the security door to open.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.2 4.1.2 Closing the Security Door
Step 1
With the security door handle turned counter-clockwise, close the security door and turn the security door handle clockwise until it is locked. The electronic lock mechanism will lock itself once the T-handle has returned to its vertical position. The dial combination lock must be turned counter- clockwise to lock.
Step 2
Check the T-handle to make sure the lock has locked itself.
Step 3
With the security cover key turned clockwise, close the security cover and urn the security cover key counter-clockwise until locked. Remove the key when it is locked.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.3 4.1.3 Opening the top Bezel
Step 1
The upper bezel lock on the Genmega 1900 is located on the back side of the top of the machine. Insert the Bezel key and turn it clockwise to open.
(Optional Topper Shown)
Step 2
With the Front Panel key turned, pull the Front Panel outward.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.4 4.1.4 Closing the top Bezel
Step 1
Push the Front Panel slowly until it is against the lock mechanism. Note: you must unlock the top bezel lock before the bezel will close all the way.
Step 2
To lock the top bezel, turn the Bezel key counter-clockwise until the key can be removed.
(Optional Topper Shown)
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.5 4.1.5 Operating and Changing the Combination Lock (non-electronic)
Before operating the lock or changing the combination, READ THE INSTRUCTIONS THOROUGHLY.
At the top of the dial ring, an index is provided for normal dialing and opening. At the side of the opening index (11 o'clock), a changing index is provided for use only when setting a new combination.
This is a precision lock; therefore, extreme care must be used to align the combination number with the index.
Turn the dial slowly and steadily. If after turning the correct number of revolutions, any number is turned beyond the index, the entire series of combination numbers must be re-dialed. DO NOT TURN BACK TO REGAIN A PROPER ALIGNMENT WITH THE NUMBERS. Each time a selected number is aligned with the opening index, a revolution is counted.
Please contact your distributor or consult manufacturers lock manual for default lock combination
Step 1 Turn the dial to the LEFT, stopping when the first number is aligned with the opening index, the FOURTH time.
Step 2 Turn the dial to the RIGHT, stopping when the second number is aligned with the opening index, the THIRD time.
Step 3 Turn the dial to the LEFT, stopping when the third number is aligned with the opening index, the SECOND time.
Step 4 Turn the dial slowly to the RIGHT until the bolt retracts.
TO LOCK
Turn dial to the LEFT at least four full revolutions.
CAUTION: Before closing the vault door, try the new combination several times using the opening index. Changing Index Opening Index Section 4: Operation Operator Manual
G1900 Genmega 2011 4.6 Changing to a New Combination
To make up a new combination, select 3 sets of numbers of your own choosing. DO NOT USE NUMBERS BETWEEN 0 AND 20 FOR YOUR LAST NUMBER DO NOT USE NUMBERS ENDING IN 0 OR 5 DO NOT USE NUMBERS IN A RISING OR FALLING SEQUENCE (e.g. 35-50-75)
Insert Figures (3)
Step 1 Using the changing index, dial the existing combination as explained in paragraphs 1-3 above.
Step 2 Hold the dial with the last number at the changing index and insert the changing key in the keyhole in the back of the lock. Insert the key until the wing is entirely inside the lock and comes to a positive stop.
Step 3 Turn the key one-quarter turn to the RIGHT or clockwise. With the changing key in this position, turn the dial to the LEFT; stopping when the first number of the newly selected combination aligns with the changing index the FOURTH time.
Step 4 Turn the dial to the RIGHT, stopping when the second number is aligned with the changing index, the THIRD time.
Step 5 Turn the dial to the LEFT, stopping when the third number is aligned with the changing index, the SECOND time. Holding the dial in this position, turn the changing key back to the LEFT or counter-clockwise and remove it. The new combination you have chosen is now set in the lock.
WARNING: NEVER INSERT THE CHANGING KEY IN THE LOCK WHEN THE COVER IS REMOVED. ALWAYS BE CERTAIN THAT THE WING OF THE CHANGING KEY IS ENTIRELY WITHIN THE LOCK BEFORE TURNING THE KEY. IF AN ERROR HAS BEEN MADE IN SETTING A NEW COMBINATION, WE SUGGEST THAT AN ACCREDITED LOCKSMITH BE CONTACTED.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.7 4.1.6 Operating and Changing the Electronic Lock
Before operating the lock or changing the combination, READ THE INSTRUCTIONS THOROUGHLY*.
*See manufacturers lock manual included in the Open Me First Box
The LA GARD LG Basic series electronic lock uses a touch key pad for all lock functions.
Power is supplied to the lock via a standard 9-volt Alkaline battery which contained within the external portion of the lock. The lock will warn of low voltage by repeatedly beeping.
TO UNLOCK FROM DEFAULT COMBINATION
Step 1 Press the default combination one button at a time, (see lock manual or consult your dealer for default combination). A beep is heard following each key press.
Step 2 If the combination is entered correctly a double-beep is heard and the internal lock solenoid will click indicating that the lock is open and the vault handle my now turn.
Step 3 If the wrong combination is entered a triple-beep will be heard. If the correct combination is not entered within 4 consecutive attempts a 5 minute delay or lock out will begin. During this time, the led at the 2 oclock position on the face of the lock will flash at 10 second intervals. In addition any key press will respond with a triple-beep. Once the 5 minutes has elapsed, 2 more consecutive failed attempts will restart the 5 minute timer.
WARNING: While orienting yourself with the lock, making changes to the lock programming (including changing the combination) ALWAYS work with the vault door open. Do not close the vault until the lock has been thoroughly tested.
Genmega does NOT program a master combination! Section 4: Operation Operator Manual
G1900 Genmega 2011 4.8 Changing to a New Combination
NOTE: Combination is required to be 6 digits. Combinations of less than 6 digits will not work.
Step 1 Begin by entering six zeros. ( 000000 )
Step 2 Enter the existing combination one time
Step 3 Enter the new combination twice. As each six digit sequence is entered, a beep is heard.
Step 4 If the procedure is not performed correctly, at the end a triple-beep is heard and the lock will revert back to the previous combination.
The LG Basic series lock includes several options including multiple user / manager passwords. Please consult the LA Gard manual included in the Open Me First box for instructions.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.9 4.2 CASH OPERATIONS
4.2.1 Adding Cash to the Cassette (TCDU)
Step 1
Open the Security Door. (Please see 4.1.1 OPENING/CLOSING THE SECUIRTY DOOR.)
Step 2
For Genmega 1900 with a fixed cassette dispenser (TCDU) use the following steps. For machines equipped with the removable cassette dispenser (SCDU or MCDU) please continue to Section 4.2.3.
With the security door open, remove the slide tray screw and slide the dispenser all the way out.
Step 3
Insert the key into the top of the reject bin and lift up to access the cash tray.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.10
Step 4
Push the slide the push plate located inside the cash tray back (towards the rear of the dispenser) until it latches in place.
Step 5
Press on the latch bar to release the push plate against the notes.
TIPS ABOUT ADDING BILLS:
1. Fan the notes so that the notes are not sticking together. 2. Remove all the notes with holes or notes that are torn. 3. Unfold the folded notes. 4. Place all the notes correctly.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.11 4.2.2 Emptying the Reject Bin
Step 1
Insert the key into the reject bin lock and turn to unlock.
Step 2
Pry back on the plastic tabs at the base of the arrow stickers on each side of the reject bin. Lift the reject bin lid.
Step 3
With the reject bin open, remove any notes and then close the top. Turn the key to lock the reject bin in place.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.12 4.2.3 Adding Cash to the Cassette (SCDU or MCDU)
Step 1
Open the Security Door. (Please see 4.1.1 OPENING/CLOSING THE SECUIRTY DOOR.)
Step 2
With the security door open, remove the cassette. Lift up on the handle while supporting the bottom of the cassette while removing.
Step 3
To avoid damage, never use force while removing or installing the cassette. If anything beyond gentle force is required while handling the cassette, contact your service personal.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.13
Step 4
Open the cassette using the key shown in Section 2 (page 2.2)
Step 5
Pull back on the cash plate and load the bills against the rollers at the back of the cassette. If you pull the cash plate back all the way it will lock at the front of the cassette. Push the green lever on the cash tray to release.
TIPS ABOUT ADDING BILLS:
5. Fan the notes so that the notes are not sticking together. 6. Remove all the notes with holes or notes that are torn. 7. Unfold the folded notes. 8. Place all the notes correctly.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.14 4.2.4 Emptying the Reject Bin
Step 1
To open the reject bin, pull back on the tabs located on the sides of the reject bin door.
Step 2
Remove any notes found in the reject bin and close the door by pressing it shut. Remember to include the number of bills found in the reject bin when settling the cassette.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.15 4.2.5 Loading the Receipt Paper
Step 1
Open the top Bezel. (See 4.1.4 Opening the top Bezel.)
Step 2
Place the paper onto the supplied spindle with the Coated Side Out as shown in the picture. Feed the paper out through the back, where it will curl back under the tension bar.
Step 3
Prepare the new paper roll. Note below.
NOTE: 1. Make sure the roll is in its proper roll form. (A deformed roll may cause jamming problems.) 2. When replacing the new roll, make sure the end of the roll paper is clean cut.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.16 Step 4
Feed the paper over the bar behind the roll and under the spring loaded tension bar. Slide the paper through the guides. The paper will not feed until the machine is initialized (powered on). If the paper does not feed, make sure the paper is all the way in the loading guide. Also make sure the roller assembly is closed (see below)
Step 5
The roller assembly can be opened by pressing down on the green lever in front of the printer.
Step 6
To close the roller assembly, lift up on the rollers. The roller assembly must be completely closed before the printer will operate. Press up on the roller assembly rather than on the green lever to close.
When finished loading paper, close the top bezel and remove the key.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.17 4.3 SETTLEMENT MENU
Choose Settlement from the Operator Function menu. This menu controls how many bills have been added to the ATM as well as generating Day total and Cassette total reports.
ADDING CASH
Step 1 Press the Add Cassette button.
Step 2 Using the main keypad, enter the number of bills added to the cassette (not the amount of money). Step 3 Press the enter key when finished to set the amount.
If you make a mistake and wish to zero out the current number of bills, youll need to press Cassette total to do this. Anytime you press Add Cassette you will be adding on to the current number of bills already programmed.
For example:
There are 50 bills in the cassette and in the settlement menu it says Current # of Bills = 50. You wish to add 25 more bills to the same cassette, you press Add Cassette, then type 25 from the keypad and press enter. The current number of bills will now be 75.
Now say there are 50 bills in the cassette and in the settlement menu it says Current # of Bills = 50. If you wish to remove 25 bills from the cassette, press Cassette Total. This will return the number of bills in both cassettes to zero and print a receipt showing remaining bills and loaded bills. Now press Add Cassette and enter 25 from the keypad, press enter to set. The current number of bills will now be 25.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.18 DAY TOTAL
The Day Total function keeps a running total of the ATMs transaction activity. When you press day total, the ATM will print a report showing transaction totals starting from the last time a day total was done until now. At the same time, the 1900 will dial into the Host Processor and retrieve their totals for the same time period. To the left is an example of a Day Total Report. Once the report is printed, the ATM will reset these values to 0 and begin recording from this point.
One thing to keep in mind when doing a Day Total is that the Host (or Processor) cuts off their transactions at a certain time every day. If you do a Day Total report before or after the processor has done their cut off, you may see discrepancies between what the terminal had reported and what the host reports.
To avoid this, talk to your dealer and find the approximate cut off time for your processor. Try to do your day totals at this same time. Remember that if you do not match your processor, the missing transaction(s) will usually appear on the next total. If you are unable to do your Day Total at the same time each day you can program the machine to do a Trial Day Total automatically (see section 3.2.7).
After the Day Total has printed you will be prompted on the screen that the total has printed and to press the Enter key to return to the menu.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.19 CASSETTE TOTAL
The Cassette Total function prints a report detailing the number of bills that have been loaded into the cassette and how many bills were dispensed, either to the customer, the reject bin or used during a dispenser test. This report will show totals from the last time you ran a Cassette Total to the current date. After the Cassette Total has been printed, all the values will reset to zero.
NOTE: Running a Cassette Total is the only way to clear the Settlement value back to zero bills. After the Cassette Total has printed you will be prompted on the screen that the total has printed and to press the Enter key to return to the menu.
TRIAL CASSETTE TOTAL / TRIAL DAY TOTAL These reports are identical to pressing Day Total or Cassette Total, the only difference being that they will not zero out the amounts. This report is useful if you wish to know current Total statistics without closing them out. To run these reports, simply press the button and the report will print. Press Enter when finished to return to the Settlement Menu.
NOTE: Trial Day Total can be set to process automatically at a preset time. See Section 3.2.7 for information on automated scheduling of a Trial Day Total.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.20 4.4 JOURNAL MENU
The Journal is an electronic record of all transactions, errors and some programming changes made to the ATM. Depending on the size of each entry, the memory can hold up to 40000 records. Each entry into the journal is indexed with a 5-digit sequence number starting with <00000>. Once the journal memory has reached its maximum limit, it will begin to overwrite the oldest entries. You will not be warned of this, therefore it is critical to make sure to download or print your journal often enough to avoid loosing records.
The journal can be printed from the ATM in two different methods, Standard and Condensed. Standard will give complete information for each transaction (basically a copy of the customers receipt), whereas the condensed print will only show sequence number, date, time, what type of transaction and then amount requested / amount dispensed (in case of withdrawal).
PRINT JOURNAL
Step 1 To print the journal, press the Print Journal button.
Step 2 You will be prompted to choose standard (PRINT) or condensed (CONDENSED PRINT).
Step 3 The ATM will then print all journals in memory up to the last time you printed a journal. Each time you print a journal a marker is set at that point. The next time you print the journal, the ATM will print from that marker to the current time.
END
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.21
LAST X PRINT The Last X Print option allows you to bypass the marker set when printing a journal and go back to recover an older record (so long as the record still exists in memory). For example, you print a journal and it includes sequence numbers <00001> to <00100>. If you wanted to go back and reprint journal number <00080> you would need to do a Last X Print for 20 records (100-20=80) this would give you records 100-80. To do a Last X Print, press the button and then enter a value of how many records you wish to go back.
CLEAR TRANSACTION SEQUENCE NUMBER This function will reset the journal sequence number back to <00000>. This may be useful if you switch processing or switch Terminal ID numbers and want to keep new records.
VIEW JOURNAL
View Journal allows you to visually inspect the journal records. Press the View Journal button and you will see the screen to the left.
Use the Arrow keys on the main keypad to scroll through the records. You can also use the buttons next to +50 and -50 to go forward or backwards 50 records at a time. Use the Enter button to print the journal entry currently displayed. Press Cancel to exit this menu.
CLEAR JOURNAL Clear Journal sets the current journal marker to the most recent journal recorded. It does not delete the journal from memory. For example: You currently have 100 entries in your journal, you press Clear Journal. Now if you press Print Journal, nothing will happen because there are no current journal entries, however if you used Last X Journal, you could enter 100 and get all the records.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.22 4.5 REPORTS MENU
The reports menu provides statistical information as well as troubleshooting and error information.
ERROR CODE
If the machine is out of service, and you are unfamiliar with the error code being displayed (or none is displayed), this screen will provide error descriptions as well as corrective action for the currently displayed code. Press the Error Code button to enter this screen. You can also use you left and right arrow keys on the main keypad to scroll through all the possible error codes and descriptions the ATM can report. To the left is an example of an Error Code screen.
S/W VERSION This screen provides the current revisions of software used in your ATM. This information may be used to troubleshoot a problem, or simply to make sure that the software being used is up to date. It is useful to have this information when reporting a problem to your dealer / distributor. Occasionally check with your dealer / distributor for software updates. Press the S/W Version button to view the current revisions. Press Enter key to print a copy of the displayed information.
Section 4: Operation Operator Manual
G1900 Genmega 2011 4.23 PRINT ALL SETUP The Print All Setup report is a complete listing of all the programming details for your ATM. It includes everything from software versions to message screens and host setup parameters. This report is extremely important when troubleshooting problems. It is highly recommended to keep a copy of this on hand for when you need to contact your service personal. To print the report, press the Print All Setup button, when the report is finished it will prompt you to press Enter to return to the Reports Menu.
ERROR SUMMARY
This report is a running total of all errors that have occurred to your ATM. It lists the errors by the number of times they occurred. Sometimes your machine can go out of service and no error code is displayed (usually with communications problems). If this happens, check the error summary, as the code will be displayed here. You can print these errors To the left is a sample of an error summary report.
Press Clear to clear the report and start over. This can be useful if you have a machine were multiple errors are occurring. If you clear the error codes and then attempt a transaction, if that transaction fails, the error summary will only show those errors that occurred during that last transaction. You can also print the error summary list by pressing the Print button.
STATISTICS This report keeps running averages of transaction information, including:
Withdrawal Transactions per day Non-Cash withdrawals per day (if enabled) Balance Transactions per day Transfer Transactions per day Notes Dispensed per day Surcharge amount collected per day
Section 5: Diagnostics Operator Manual
G1900 Genmega 2011 5.1 DIAGNOSTICS
5.1 DIAGNOSTICS MENU
The ATM features built-in diagnostics features to assist you in troubleshooting any problems that may develop. Below is the main diagnostics menu.
CASH DISPENSER This will test the ability of the cash dispenser to pull a note from one or both cassettes (based on how the CDU is programmed) and send it to the reject bin. You can choose from the first cassette, second cassette or both cassettes at once.
NOTE: You must have bills entered into Settlement before running this test.
PRINTER This test will print a test receipt. If the test is successful you should receive a receipt with three sets of sample characters for each time the test is run.
MODEM The modem test will allow you to enter a phone number into the machine and test dial. To run the test, press the Modem button and then press Test Dial. Using the main keypad, enter a phone number to be dialed (for example your cell phone number) and then press <Enter>. The modem should dial out to the number you entered. To end the call press Modem Hang up. In most cases a failure during the modem test will relate more to phone line problems rather than the modem circuit itself.
Section 5: Diagnostics Operator Manual
G1900 Genmega 2011 5.2
KEYPAD This tests the keypads of the ATM. Press the Key Matrix button and a map of all keys will display on the screen. Press the different keys on each keypad (main and LCD) and the appropriate key will blink on the screen. Pressing the <Cancel> key on the main keypad will stop this test and return to the diagnostics menu.
CARD READER This will test the three tracks of the card scanner to ensure they are reading properly. Press the Card Scan Button, you will see a screen displaying the three ISO tracks. Swipe your ATM card (or any card with a magnetic stripe) and the information from that card will appear on the appropriate track. During normal operation of the ATM only ISO Track 2 is read, however during the card swipe test all three tracks are read at once.
AGING The aging test is used at the factory to test machines prior to shipping and for quality control. Selecting this test will cause the machine to perform all self tests for an unlimited amount of time.
You can select the options in the Aging Menu for which tests to perform what interval / number of times you want the tests to run.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.1 CUSTOMER TRANSACTIONS
6.1 OPENING PROCEDURES
This section explains how to place your ATM in service.
Step 1 Open the front panel and turn the power on. (see page 4.1)
Step 2 If there is no receipt paper, load the receipt paper. (see page 4.12)
Step 3 Open the security door and replenish the cash cassette. (see page 4.9)
Step 4 Go into the OPERATOR FUNCTION mode and input the number of bills in the cash cassette. (See page 4.14)
Step 5 Exit the OPERATOR FUNCTION MODE.
Step 6 After connecting to the processor, the terminal will be ready for service.
Step 7 If the machine is not ready for service, please check the following: 1. Determine if the phone line is properly connected; 2. Determine if all communication parameters are correct; 3. If, after doing the above steps, the ATM is still not in service, contact your service personnel.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.2 6.2 WITHDRAWAL TRANSACTION
Step 1
Insert the card.
Step 2
Enter the pin number and press the ENTER key.
Step 3
Press the WITHDRAWAL screen key.
Step 4
If a SURCHARGE option is enabled, the SURCHARGE screen will be displayed. Select YES to continue, or NO to cancel.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.3
Step 5
If YES is selected, the following screen will be displayed. Select the desired option.
Step 6
Select the desired amount to be withdrawn. If the desired amount is not displayed, select the OTHER screen key.
Step 7
After the desired amount is entered, the ATM dials the processor and requests approval for the transaction. When authorization is received from the processor, the cash will be dispensed.
The following screen will be displayed. Select the desired option. Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.5
Step 5
The ATM dials the processor and requests approval for the transaction.
Step 6
When authorization is received from the processor, the following screen will be displayed and the receipt will be printed.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.6 6.4 TRANSFER TRANSACTION
Step 1
Insert the card.
Step 2
Enter the pin number and press the ENTER key.
Step 3
Press the TRANSFER screen key.
Step 4
The following screen will be displayed. Select the desired account to be transferred FROM.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.7
Step 5
Select the target account to be transferred TO.
Step 6
Enter the desired amount to be transferred and press the ENTER key.
Step 7
The ATM dials the processor and requests approval for the transaction.
Step 8
When the authorization is received from the processor, the following screen will be displayed and the receipt will be printed.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.8 6.5 CLOSING PROCEDURE
This section explains the closing procedure for the ATM.
Step 1 Perform the DAY TOTAL and CASSETTE TOTAL functions in the OPERATOR FUNCTION MODE.
Step 2 Open the security door. Remove the cash from the Cash Cassette and Cash Reject bin.
Step 3 Print the Journal.
Step 4 If the result of the DAY TOTAL and CASSETTE TOTAL does not match the amount counted in the Cash Cassette, refer to the Journal for verification.
Step 5 Turn the power off and close the security door.
Section 6: Customer Transactions Operator Manual
G1900 Genmega 2011 6.9 6.6 ERROR RECOVERY
If an error occurs the following screen will be displayed.
Step 1
To access the Operator Function menu, press the following keys in order <Cancel>, then <Clear>, then <Enter> then 1, then 2, then 3.
Step 2
Verify the Error that has occurred through the ERROR CODE of the REPORT MENU in the OPERATOR FUNCTION, menu and perform the corrective action, then press the DEVICE INITIALIZE screen key.
If the Error is not corrected after resetting, contact your service personnel.
Appendix A: Error Codes Operator Manual
G1900 Genmega 2011 A.1 APPENDIX A: Error Codes
ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION 20001 Unable to load a cassette. Remove and replace cassette Check the micro-switch located on the inside left wall of the dispenser. 20002 Low Cash. Replenish the cash If using less than 75 bills, disable the Low Cash Warning in the Transaction Setup Menu. 20003 Reject Bin full. Empty the Reject Bin If the bin is empty, do a Day Total and then a Cassette Total If that doesnt help, check AP, BIOS and CDU ROM versions. 20004 Vault Door is open. Check vault door switch (located upper left corner) check that black and white, 2-wire connector is properly connected at rear of main board. Bend switch forward to aid closing problems. 20010 Receipt paper jam. Remove jammed paper Release receipt paper drawer by pressing the tab with the green sticker located at the front of the printer. Remove printer to locate difficult jams. 20012 Receipt feed lever open. Close the feed lever on the printer. 20013 Receipt paper empty. Replenish the paper roll. 20014 Thermal printer is overheated. Contact manufacturer. 2xx15 Cash Dispenser detects bills prior to dispensing. Remove any jammed bills from the dispenser. 90001 Card Swipe Error. This does not mean the card reader is bad. Just records unsuccessful attempts at swiping cards. Axxx1 Receipt Printer feed lever open during operation. Close the feed lever on the printer. Axxx2 Thermal printer is overheated during operation. If problem is consistent then print head assembly may be defective. Axxx3 Receipt paper jam. Remove jammed paper Release receipt paper drawer by pressing the tab with the green sticker located at the front of the printer. Axxx4 Receipt paper is empty. Replenish the paper roll. Axxx5 Receipt paper is jamming during loading. Remove any jammed paper and then reload. Axxx8 Receipt Printer cutter error. If consistent, printer will require repair/replacement. ADNxx Printer connection error. Check cables between Printer and Mainboard. Remove cables (even though they may be attached) and reconnect. CANCE Surcharge Cancel Customer has canceled the transaction at surcharge. C0011 Exit sensor is not cleared Check sensor, verify that the cabling plugged into the sensor boards is secure. C0012 Reject gate timing sensor not cleared. Check dispenser for jammed bills and reinitialize the machine. C0013 Both reject gate and exit sensor not cleared Check dispenser for any notes or obstructions. C0017 Undefined C0021 Double detect sensor is not cleared. Check dispenser for jammed bills and reinitialize the machine. C0022 1 st cassette inlet sensor not cleared. Check dispenser and cassette for jammed bills. C0023 Cassette exit sensor (L+R) not cleared. Check dispenser for jammed bills and reinitialize the machine. Appendix A: Error Codes Operator Manual
G1900 Genmega 2011 A.2 ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION C0028 Count sensors not cleared Check dispenser for jammed bills and reinitialize the machine. C0030 Main Motor encoder is not synchronized Turn dispenser over by hand, and then reinitialize. May require repair. C0031 Forward motor encoder not synchronized. Turn dispenser over by hand, and then reinitialize. May require repair. C0032 1 st cassette inlet sensor not cleared Check for notes where the cassette engages the dispenser. C0033 Undefined C0036 Exit sensor blocked while initializing Clear any notes which may be blocking the exit sensor. C0037 Invalid response (or no response) from double detect sensor Verify the connection to the double detect module. C0039 Solenoid not responding Verify the function of the gate solenoid. C003A Too many notes requested during a test dispense Test dispense failed, re-run the test and check notes. C0041 Failed (5 times) to dispense a note after a successful dispense Check why notes are rejecting following at least one successful dispense (in the same transaction). C0042 Undefined C0043 10 Notes rejected in a row (single transaction) Check the notes in the cassette. Check reject analysis for source of rejected notes (long note, double-detect, etc) C0044 5 notes consecutively rejected Check reject analysis for cause of rejected notes. C0045 Note count sensor reporting mismatch Verify count of notes in the cassette against the settlement. C0046 Undefined C0047 1 st cassette failed to dispense a note Most common reason is cassette is empty. Verify that there are notes in cassette 1. Check the quality of the notes and condition of the pick rollers. C0049 Dispense request of 0 notes Check setup of CDU in Operator Menu, dispenser may need reprogramming. C004A First cassette exit sensor (#6, #7) not clear Clear the note path of any notes or obstructions. C004D 1 st cassette not inserted Check cassette and verify that its inserted properly. C004E 2 nd cassette not inserted Check cassette and verify that its inserted properly. C0050 AP does not receive response after dispense request AP did not validate dispense command. This is an AP software fault, not CDU. C0051 Exceeded maximum number of notes dispensed (150) in a single trans. Check reject analysis, and verify test dispense. C0052 1 st cassette inlet sensor not cleared Check for notes where the cassette engages the dispenser. C0053 Abnormal amount of double-detect failures during dispense Check condition of double-detect module. Check quality of notes and pick rollers. C0054 Undefined C0055 Long note detected at exit sensor during dispense Clear any jammed notes or obstructions from the exit sensor. C0056 Short note detected at exit sensor during dispense Clear any jammed notes or obstructions from the exit sensor; mismatch of rejected notes.
Appendix A: Error Codes Operator Manual
G1900 Genmega 2011 A.3 ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION C005A Undefined C005B 2 nd cassette fails to pick up notes Same as C0047, the second cassette is likely empty. C0060 3 rd cassette inlet sensor not cleared Check for notes where the 3 rd cassette engages the dispenser. C0062 3 rd cassette inlet sensor not cleared Check for notes where the 3 rd cassette engages the dispenser. C006A Note jam at 2 nd cassette exit Check rollers and sensors where notes would leave the 2 nd
cassette. C0070 4 th cassette inlet sensor not cleared Check for notes where the 4 th cassette engages the dispenser. C0072 4 th cassette inlet sensor not cleared Check for notes where the 4 th cassette engages the dispenser. C007A Note jam at 4 th cassette exit Check rollers and sensors where notes would leave the 4 th
cassette. C007C 4 th cassette fails to pick up notes Same as C0047/C005B, verify that there are notes in the 4 th cassette. C007D 4 th cassette not inserted Check cassette and verify that its inserted properly. C0080 2 nd cassette inlet sensor not cleared Check for notes where the 2 nd cassette engages the dispenser. C0081 Double detect sensor not cleared while dispensing Check double-detect senor for note or obstruction. C0082 Note leaving cassette exit sensor did not reach DD A note seen at cassette exit sensors did not reach the double detect module. Check for jammed notes. C0083 Reject gate timing sensor #2 not cleared during dispense. Clear the note path before the reject gate. C0084 Reject gate timing sensor #3 not cleared during dispense. Clear the note path before the reject gate. C0085 Note leaving DD sensor did not reach gate sensor Check the note path for jammed or diverted notes. Check sensors from #5 to #2/#3. C0086 Note leaving gate sensor did not reach count sensor Check for jammed notes between #2/#3 sensors and #0/#1 sensors. C0090 Sensor check error Left measuring sensor A (#6/#7) C0091 Sensor check error Right measuring sensor B (#6/#7) C0092 Sensor check error Left gate timing sensor A (#2/#3) C0093 Sensor check error Right gate timing sensor B (#2/#3) C0094 Sensor check error Exit sensor (#4) C0095 Sensor check error Double Detect (#5) C0096 Sensor check error Left count sensor A (#0/#1) C0097 Sensor check error Right count sensor B (#0/#1) C009A Note jam at 3 rd cassette exit Check rollers and sensors where notes would leave the 3 rd
cassette. C009D 3 rd cassette not inserted Check cassette and verify that its inserted properly. C009F 3 rd cassette fails to pick up notes Similar to C0047, C005B verify that there are notes in the cassette. D0001 Modem initializing failure. This error is reported from the host. Check that programming is correct for this processor. D0002 Reversal transaction failed. Check transaction with the processor. Verify CDU functionality with diagnostics. Verify phone connection. D0012 Invalid transaction. Network denial code. D0013 Invalid Amount. Network denial code. D0014 Invalid Card Number. Network denial code. D0020 Surcharge screen should have been displayed. Network denial code. Appendix A: Error Codes Operator Manual
G1900 Genmega 2011 A.4 ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION D0024 Exceeds issuer withdrawal limit. Network denial code. D0039 No credit account. Network denial code. D0051 Insufficient funds. Network denial code. D0052 No checking account. Network denial code. D0053 No savings account. Network denial code. D0054 Expired Card. Network denial code. D0055 Invalid PIN. Network denial code. D0057 Transaction not permitted card Network denial code. D0058 Transaction not permitted Terminal Network denial code. D0061 Exceed withdrawal limit. Network denial code. D0075 Number of PIN tries exceeded. Network denial code. D0078 No Account. Network denial code. D0080 Invalid Date. Network denial code. D0083 Cannot verify PIN. Network denial code. D0086 Cannot verify PIN. Network denial code. D0091 Bank unavailable. Network denial code. D0092 System unavailable. Network denial code. D0093 Transaction serial number mismatch. Contact host processor. D0094 Record format mismatch. Contact host processor. D0095 Routing ID mismatch. Verify Routing ID number Contact host processor. D0096 Terminal ID mismatch. Verify Terminal ID number Contact host processor. D0097 Response type mismatch (reversal). Contact host processor. D0098 Response type mismatch (day-close). Contact host processor. D0099 Response type mismatch (Configuration). Contact host processor. D009A Response type mismatch (Withdrawal, Balance, Transfer). Contact host processor. D009B STX omitted. Contact host processor. D009C ETX omitted. Contact host processor. D009D FS omitted (after response code). Verify that version of ATM Software matches host processor. Contact host processor. D009E FS omitted (after retrieval reference number). Verify that version of ATM Software matches host processor. Contact host processor. D009F FS omitted (after system trace audit number). Verify that version of ATM Software matches host processor. Contact host processor. D00A0 FS omitted (after account balance). Verify that version of ATM Software matches host processor. Contact host processor. D00A1 FS omitted (after available balance). Verify that version of ATM Software matches host processor. Contact host processor. D00A2 FS omitted (after available balance). Verify that version of ATM Software matches host processor. Contact host processor. D00A3 FS omitted (after authorization response text). Verify that version of ATM Software matches host processor. Contact host processor. D00A4 ETX is in wrong place. Verify that version of ATM Software matches host processor. Contact host processor.
Appendix A: Error Codes Operator Manual
G1900 Genmega 2011 A.5 ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION D00A5 FS omitted (after total cash dispense amount in day close). Verify that version of ATM Software matches host processor. Contact host processor. D00A6 FS omitted (after total non cash dispense amount in day close). Verify that version of ATM Software matches host processor. Contact host processor. D00A7 FS omitted (after surcharge amount in day close message). Verify that version of ATM Software matches host processor. Contact host processor. D00A8 FS omitted (after surcharge in configuration message). Verify that version of ATM Software matches host processor. Contact host processor. D00A9 ETX omitted (from configuration message). Contact host processor. D0300 Modem is not responding. Verify modem function. D1000 No Connection. Verify modem function. D1100 ENQ not received from host. Contact host processor. D1200 Transmission error. Verify modem function. D1300 NAK sent 3 times to host. Verify host phone number See D170x. D1500 Modem connection time out host not responding. Verify host phone number verify modem speed See D170x. If consistent, it could be a defective modem. D170x Modem cannot support connection excessive line noise (usually D1704/06) Phone line connected to ATM will not support Data- communication. In line filter may fix this. Excessive EMI emissions from outside source (neon sign, freezer). D1800 No dial tone. Verify that incoming phone line is plugged into line rather than Phone on mainbaord. Phone line is in use or is being shared with another phone device (FAX, POS, phone) D1900 No answer. Verify host phone number See D170x D2000 Phone line busy. Verify host phone number call line with handset and check for busy signal See D170x D2100 Modem initializing error. Check modem. D2200 EOT not received from host. Contact host processor. D25xx Network Connection See page 3.33 of Operator Manual E000x RMS port failure, response time out, modem failure, no dial tone. Verify RMS settings (Host Setup) See D170x F0001 Current Number of bill is 0. Load notes into the cash cassette use Add Cassette function in Settlement. F0002 No Surcharge Owner set. Set Surcharge owner (Customer Setup) F0003 No Surcharge Amount. Set Surcharge amount (Customer Setup) F0004 No refresh time set when advertisement is enabled. Set refresh timer (Customer Setup) F0005 No Advertisement text when advertisement is enabled. Set Advertisement text (Customer Setup) F0006 Dispense limit set error (less than 25 notes) Set Dispense limit (Transaction Setup) F0007 Denomination Set error. Valid Denomination are $10, $20, $50, $100 (Transaction Setup) F0008 Fast Cash Set error (exceeded dispense limit). Check the Fast Cash amount. (Transaction Setup) F0009 Master Key index is invalid. Check Master Key index verify checksum (Host Setup) Appendix A: Error Codes Operator Manual
G1900 Genmega 2011 A.6 ERROR CODES ERROR DESCRIPTION CORRECTIVE ACTION F000A Master Key is empty. Check Master Key checksum reinject key (Host Setup) F000B Host Telephone Number is not set. Set Host Telephone Number (Host Setup) F000C Error Retry timer is not set. Set Error retry time (Host Setup) F000D RMS Password is not set when RMS is enabled. Set RMS Password (Host Setup) F000E RMS phone number is not set when RMS send is enabled. Set RMS Phone number (Host Setup) F000F Terminal ID is not set. Set Terminal ID number (Host Setup) F0010 Routing ID is not set. Set Routing ID number (Host Setup) F0011 Master Key Serial number is not set Set Master Key serial number (Host Setup) F0013/ 14 NVRAM Failure Fatal error, defective memory chip. Replace Mainboard. F0015 Serial Number not Set Set Serial number in Operator Menu F0016 Master Password left at default ATM will not go into service with the default master password. The master password must be changed from default.
Appendix B: Keypad Addendum Operator Manual
G1900 Genmega 2011 B.1 APPENDIX B: CLEARING NVRAM
To clear NVRAM on the Genmega G1900, begin by entering the Operator Function Menu using the Master Password. Next enter the Customer Setup Menu.
Press the lowest button on the right side of the LCD panel. This will give you access to the CLEAR NVRAM Menu.
*** WARNING ***
Once in the CLEAR NVRAM Menu, there is no extra authorization before data will be wiped out permanently. DO NOT press any key within this menu unless you are absolutely sure you want to permanently delete this data!
CLEAR JOURNAL Selecting this will delete all journal data permanently
CLEAR NVRAM This will delete all programmed parameters and return everything (including passwords) to the default settings. This does NOT include the master keys which are stored in the EPP.
CLEAR JOURNAL AND NVRAM This option performs both of the options listed above. Both the programmed parameters and journal are permanently deleted and all settings are returned to default.
USE CAUTION WITH THESE FEATURES DATA LOST CANNOT BE RECOVERED
Master keys are entered only through an approved EPP (Encrypting Pin Pad) device and are stored in the keypad. These keys, along with another key downloaded from your processor are used to encrypt the PIN numbers for customer transactions.
Two Passwords (Secure Mode Passwords) are required in order to enter Key Mode and change any options.
NOTE: You will NOT be able to enter keys or change key mode until the Secure Mode Passwords have been changed from default. After changing both passwords, you must back out of the operator menu and reinitialize the ATM.
Please follow the procedures below to begin this process.
Installation Procedure:
To access the Key Management menu from Host Setup, youll need to enter the Secure Mode Password (parts 1 and 2). See page 3.6 for Secure Mode instructions.
Default Secure Mode password is:
Part #1 = 000000 / Part #2 = 000000
Access the Key Mode selections by entering the operator function menu
[ENTER]+[CLEAR]+[CANCEL] + 1 + 2 + 3
Enter Master Password and choose Host Setup
Note: Master Password is required to access Key Management Menu.
NOTE: You must change the Secure Mode Password from default before any changes can be made to Key Management, or enter any keys. Change the default passwords for Part #1 and Part #2 and then completely exit the Operator Menu (cancel out and let machine initialize) Once you go back in and use the new Secure Mode Passwords, youll be able to make changes or enter keys.
Appendix C: TDES Key Installation Operator Manual
G1900 Genmega 2011 C.2 1) Select Key Mode
The table below describes the format for each key mode.
DES 2 - 16 digit master keys entered as Part A and Part B. Dual Master Key 2 - 16 digit master keys entered as Part A and Part B (a common key is entered, and then a working key is downloaded from the host). Unique Key, DES 2 - 16 digit master keys entered as Part A and Part B - with 10 digit unique serial number entered prior to each part. TDES 2 32 digit master keys entered in 16 digit pieces, Part A (left and right) and Part B (left and right) Unique Key, TDES 2 32 digit master keys entered in 16 digit pieces, Part A (left and right) and Part B (left and right) - 10 digit unique serial number entered prior to each part. MAC 2 -16 digit master keys entered as Part A and Part B, with 2 additional 16 digit numbers entered as MAC Part A and Part B Unique Key, MAC 2 -16 digit master keys entered as Part A and Part B, with 2 additional 16 digit numbers entered as MAC Part A and Part B - 10 digit unique serial number entered prior to each part of the master key only. TDES, MAC 2 32 digit master keys entered in 16 digit pieces, Part A (left and right) and Part B (left and right), with 2 additional 16 digit numbers entered as MAC Part A and Part B
Under most circumstances, youll be using TDES as Key Mode.
Unique Key modes use a unique 10 digit serial number that is entered before each half of the master key to allow the processor to bind the key to the terminal ID automatically. In cases where the processor provides a serial number that is less than 10 digits, zeros must be added at the beginning of the number to equal 10 digits.
Appendix C: TDES Key Installation Operator Manual
G1900 Genmega 2011 C.3
2) Entering A Master Key
Master Key security requires that no one person has access to all parts of the key. To ensure this, the processor will provide keys in separate sealed envelopes (sometimes referred to as key components). Each envelope contains either one or two 16 digit keys and in the case of unique key, a serial number. The diagram below shows a sample Unique Key, TDES master key.
Begin by choosing Edit Master Key from the menu
Depending on Key Mode, the menu prompts for Part A and Part B.
The Edit Master Key interface is designed so that Parts A and B can be entered at completely different times and in either order (Part A first, or Part B first). If a technician is dispatched to enter a key part, choose Check Key from the Key Management menu to determine which part of the key has already been entered.
Appendix C: TDES Key Installation Operator Manual
G1900 Genmega 2011 C.4
Partially entered keys will appear in the index as #### or **** which denotes that either part A or part B has been successfully entered. (A = #, B = *)
This would tell the second technician that they need to enter their key as Part B on index 12.
Part1 = Part A / Part2 = Part B
Once you have selected Part A or B, youll be prompted to enter a Key Index.
This index points to the location where the key will be stored. There are 16 possible memory locations (0-15) available. Unique master keys must be stored at location #12, and MAC keys at location #15.
The interface will default the values for Unique and MAC keys regardless of what you enter. It is very important to remember that both parts of a key must be entered on the same index. If you enter Part A on index #2 and Part B on index #3 the key will not be complete. Use the Check Key function (shown above) to determine where your keys parts have been entered.
If entering a Unique key, next youll be prompted to enter the key serial number.
This 10 digit number is found on the paperwork containing your master key(s). If the number the processor has provided is less than 10 digits, youll need to add zeros to the beginning of the number to equal 10 digits.
In the example shown at left, the serial number is 123456. This 6 digit number would be changed to 0000123456 to create 10 digits.
Appendix C: TDES Key Installation Operator Manual
G1900 Genmega 2011 C.5
The next step is to enter the master key itself. If you are using TDES, youll need to enter the left portion first.
After entering the key, youll be prompted to enter it a second time for verification.
The 16 digit alpha-numeric key is entered using the pin-pad only.
Letters are entered by using the arrow and function keys. Use the pin-pad layout below.
G1900 Genmega 2011 C.6 At this point the left (or first 16 digit) portion of the master key has been entered successfully.
If you are entering a 32 bit key (TDES), the second or Right half of the key is entered next.
This option will only appear when in TDES mode.
After entering the right portion of the key successfully youll be prompted with a check digit as shown below. Verify the check digit with the information provided by the processor.
Check digits appear after entering both the right and left portion of each part of the key.
Compare the check digit against the number located at the top of the key component. This represents a check digit for the combined keys. There is not a check digit shown for left and right portions individually. Appendix C: TDES Key Installation Operator Manual
G1900 Genmega 2011 C.7
After successfully entering both the left and right portions of Part A, youll be returned to the Edit Master Key menu.
At this point you can proceed with Part B, or if Part B is to be entered at a later time you can exit the menu and power off the machine until both halves of the key are entered.
Part B is entered with the same procedure given for Part A. Enter the left and right (for TDES) portions of the keys and verify the check digits against what has been provided by the processor.
3) Verifying Master Key
Once both Part A and Part B have been entered successfully, the key management menu will display a check digit for the key index where the master key was entered. If no check digit is entered, use the check key screen to determine where the key parts were entered, then re-enter the keys as necessary.
At this point, the master key is successfully entered. If all other parameters have been entered properly, power off the ATM and power on to connect to host and initialize the keys.
Advertisement screens can be loaded to the Genmega G1900 machine either using a SDRAM card (at the ATM) or by using remote monitoring software (to load remotely). Please see below for basic file format specifications and instructions for use with a SDRAM card.
You can have up to 8 center graphic files and must be named as followed:
center1.bmp, center2.bmp, and so on up to center8.bmp
DO NOT use more than 256 colors when creating the graphic images. The G1900 was designed to use graphics of that format for efficiency and best performance*
WELCOME C Ce en nt te er r A Ad dv ve er rt ti is se em me en nt t G Gr ra ap ph hi ic c Width : 422 Pixels Height : 309 Pixels File Name center1.bmp center2.bmp .. center8.bmp (default on) File Size : 204,888 BYTES bmp File Format : 8bit (256 colors) BMP : No Compression Appendix D: Graphics Installation Operator Manual
SD card should be less than 2GB capacity and formatted as FAT or FAT16 file system
SD card reader is required to load files from your PC
To prepare the SD card for uploading graphics. 1. Remove all the data from the SD card. 2. Create a blank file called update.acu and save it on the card.
To create this file: a. Open up a blank notepad document. [Start All Programs Accessories Notepad] b. Save the blank document as update.txt in the SD card.
c. Once its saved rename the file to update.acu.
once renamed, the icon changes
After the update.acu file has been created, copy it to the root folder of the SD card.
Appendix D: Graphics Installation Operator Manual
G1900 Genmega 2011 D.3 3. Open the SD card in My Computer, and create a folder called Common. 4. Open the Common folder, and create a sub-folder called img4SCR. 5. Inside the img4SCR folder is where you want to copy all your graphic files. - The graphic files must follow the naming convention that we describe on page 1. (ie: center1.bmp, center2.bmp or top1.bmp, top2.bmp).
6. Once your graphic files are copied, insert the SD card into the SD card slot on the mainboard located behind the LCD. 7. Power off, then power on the 1900 with the power supply switch. 8. When the ATM is fully initialized then remove the SD card.
Enabling the Center Graphics: 1. Go into the Operator Menu. 2. Then to Customer Setup > Graphics > Advertise EN/Disable and go through each advertisement you want to show up and turn it ON.
Enabling the Banners Graphics: 1. Go into the Operator Menu. 2. Then to Customer Setup > Graphics > Banner EN/Disable and go through each banner you want to show up and turn it ON.
Windows XP users:
Before creating the file in step #2, you may need to change your file options. Open a folder and click on Tools, select Folder Options
Make sure Folder Options match those shown here. Specifically the Hide extensions for known file types option which needs to be unchecked.
If these options are not set properly, the update.acu file may not function, causing the graphics to not load.