1. INTRODUCTION
1.1 Features
1.1.1 Genmega G1900 Series ATM
1.2 Specifications
Genmega G1900 Specifications
1.2.1 Dimensions and Component Locations
1.2.2 Front Panel Identification
1.2.3 Cash Dispensing Unit
1.2.4 Receipt Printer
1.2.5 Main Control Board
1.2.6 Operating Environment
1.3 Warranty/Service

2. INSTALLATION
2.1 Genmega G1900 Installation
2.1.1 Unpacking
2.1.2 Physical Installation
2.1.3 Hardware Setup

3. PROGRAMMING
3.1 Initial Setup
3.1.1 Accessing the Operator Function Menu
3.1.2 When An Error Occurs
3.1.3 EPP Keypad
3.2 The Host Setup Menu
3.2.1 Key Management
3.2.2 Set Terminal ID Number
3.2.3 Connect Timer
3.2.4 Set Routing ID Number
3.2.5 Set Host Telephone Number
3.2.6 Health Check Message
3.2.7 Remote Monitor
3.2.8 Trial Day Total
3.3 The System Setup Menu
3.3.1 Set Clock
3.3.2 Optional Languages
3.3.3 Speaker Volume
3.3.4 ISO 1/3 En/Disable
3.3.5 Change Passwords
3.3.6 Device Setup
3.3.7 Set Reboot Time
3.3.8 Serial Number
3.4 Customer Setup Menu
3.4.1 Change Message
3.4.2 BIN Lists
3.4.3 Optional Features
3.4.4 Change Processor
3.4.5 Surcharge Mode
3.4.6 Graphics

Table of Contents Genmega Operator Manual


G1900
Genmega 2011
3.5 Transaction Setup
3.5.1 Dispense Limit
3.5.2 Denomination
3.5.3 Fast Cash
3.6 TCP/IP Setup

4. OPERATION
4.1 Opening and Closing
4.1.1 Opening the Security Door
4.1.2 Closing the Security Door
4.1.3 Opening the top Bezel
4.1.4 Closing the top Bezel
4.1.5 Operating and Changing the Combination Lock
4.1.6 Operating and Changing the Electronic Lock
4.2 Cash Operations
4.2.1 Adding Cash to the Cassette (TCDU)
4.2.2 Emptying the Reject Bin (TCDU)
4.2.3 Adding Cash to the Cassette (MCDU)
4.2.4 Emptying the Reject Bin (MCDU)
4.2.5 Loading the Receipt Printer
4.3 Settlement Menu
4.4 Journal Menu
4.5 Reports Menu

5. DIAGNOSTICS
5.1 Diagnostics Menu

6. CUSTOMER TRANSACTIONS
6.1 Opening Procedure
6.2 Withdrawal Transaction
6.3 Balance Inquiry Transaction
6.4 Transfer Transaction
6.5 Closing Procedure
6.6 Error Recovery

APPENDIX
A. Error Codes
B. Clear NVRAM
C. Master Key installation
D. Custom Screen Graphics


Introduction Operator Manual

G1900
Genmega 2011 1.1
FEATURES

1.1.1 The Genmega G1900

Introducing the Genmega G1900 series retail ATM. Designed and engineered to meet
the needs of the highly competitive retail ATM market, this innovative machine
combines all the features you expect, built on a flexible platform allowing you to
custom fit each machine to its location and traffic volume.

Packed with features like a 7 high-resolution LCD screen, ready for your custom
advertisements and a reliable dual-head swipe card reader (upgradable to DIP and
EMV). The G1900 Series vault has been reinforced along the door edge, and a
flashing security LED added to help prevent physical attacks.

In addition to the dispensing options offered by Genmega, including drawer,
cassette, and multi-cassette devices, the Genmega G1900 series supports several
other popular dispenser models including the De La Rue SDD and the Puloon
LCDM1000 providing an economical upgrade for existing machines

H/W FEATURES

UL 291 Business Hour Service Vault featuring reinforced steel bottom & dial lock
7 high-resolution, wide-screen TFT LCD
56K modem + Ethernet TCP/IP with SSL encryption
800 note fixed cassette dispenser (TCDU)
1000 note removable cassette dispenser (SCDU)
1700 note removable cassette dispenser (MCDU)
Dual Cassette 3400 note (1700x2) dispenser
Dual Head Swipe-type magnetic card reader (EMV Optional)
2 Thermal receipt printer
Modular design for easy maintenance
Lighted transaction guidance system
Meets ADA Standards for Height, Reach and Keypad layout

FUNCTIONAL FEATURES

Electronic journal stores over 40,000 transactions
Supports English, Spanish and French languages
Availability for 8 on screen advertisement graphics
Detailed average history report feature
On-screen error code descriptions for easy service
Introduction Operator Manual

G1900
Genmega 2011 1.2
1.2 SPECIFICATIONS

Genmega G1900 SPECIFICATIONS

1.2.1 Dimensions and Component Location






































Fig. 1 Dimensions

WEIGHT: 206 lbs.

Height = 56.36
Width = 15.75
Depth = 22.29
Introduction Operator Manual

G1900
Genmega 2011 1.3




































Component Location


1. LCD & Customer Keypad 11. Security Door Handle
2. Card Reader Slot 12. Cash Dispensing Unit
3. Receipt Printer Slot 13. Receipt Printer
4. Cash Tray 14. Main Control Board
5. Front Panel 15. Ear Phone Jack
6. Front Panel Lock 16. Power Supply
7. Security Cover 17. Speaker.
8. Security Cover Lock
9. Security Door
10. Combination Lock
Introduction Operator Manual

G1900
Genmega 2011 1.4

1.2.2 Front Panel Identification



Fig. 3 Front Panel Identification
LCD
Screen Size: 7
TFT LCD
Resolution: 800 x 480 WVGA
Display Characters: 40 x 15 (Standard Characters)
8 LCD Function Keys

KEYPAD
Certified VISA compliant EPP (Encrypting Pin Pad)

Voice Guidance Port
Voice assisted operation available through the headphone jack on the front bezel
EPP Keypad
Receipt Printer
Voice Guidance
Lighted
Topper
Function Keys
Dual-Head Swipe
Card Reader
Lighted Transaction
Guidance
LCD Panel
Introduction Operator Manual

G1900
Genmega 2011 1.5
1.2.3 Cash Dispensing Unit




Cash Dispensing Unit
(1000 Note - SCDU)

CASH DISPENSING UNIT

Dispensing Speed: 2.5 notes/second
Capacity of 800 new notes (fixed cassette)
Capacity of 1000 or 1700 notes (removable)
Lockable Reject Bin
Double note detect module



*Optional dispensers include:
1700 note removable cassette
(MCDU)

3400 note dual-cassette
(1700x2)

Introduction Operator Manual

G1900
Genmega 2011 1.6
1.2.4 Receipt Printer




Receipt Printer


RECEIPT PRINTER

Thermal line printer
36 characters/line
Semi-automatic roll paper setting
Motorized front push rollers

PAPER SPECIFICATIONS

One sided thermal paper
Factory paper is thermal side out (but either way will work)
6 inch outside diameter roll
2 inch wide
Core inside diameter 11/16 inch
21# weight (paper thickness)
Introduction Operator Manual

G1900
Genmega 2011 1.7
1.2.5 Main Control Board

Samsung S3C2440AL-40 RISC 32-bit CPU
64 MB RAM
WinCE 5.0 Operating System
Modem: 56,000 bps dial-up modem
TCP/IP Ethernet connection - Onboard SSL
Electronic Journal: 40,000 transactions
Battery back-up for set-up parameters (NVRAM)
Real time clock

1.2.6 Operating Environment

POWER REQUIREMENTS

110/220 VAC 10%, 50/60 Hz, 145 Watts

POWER CONNECTIONS

For warranty purposes, Genmega requires the 1900 series ATM be connected to a
dedicated power circuit (5amp recommended). This circuit must consist of line,
neutral, and ground leads connected directly to the power circuit breaker panel. This
circuit should not be shared with any other equipment. Use of a surge protector or
uninterruptible power supply is recommended.

PHONE LINE REQUIREMENTS

The Genmega G1900 must be connected to a dedicated analog phone line. This line
must be a direct-dial analog line. It is important to disable any voice-mail included
on that phone line as it will cause the ATM not to dial out. This line should not be
shared with any other equipment at the location. Use of shielded (CAT5) phone
cable is also recommended for best performance and to reduce the chance of
interference. Digital phone lines are NOT supported.

NETWORK (TCP/IP) REQUIREMENTS

For connection to processor via TCP/IP, use an Ethernet Patch-Cable (not included).
The ATM must connect to a device (Router) that can provide DHCP support unless a
static IP address is assigned by the service provider. It is recommended the ATM
connect to a broadband router (Linksys, Netgear, Belkin) or similar device rather
than directly to a Cable/DSL modem. For advanced or corporate networks, provide
the IT staff with ATM Host IP address and Host Port information (available from your
ISO).

TEMPERATURE

In storage : 32F - 123F (0C 49C)
While operating : 40F - 95F (5C 35C)

HUMIDITY

In storage : 10% < RH < 90%, non-condensed
While operating : 15% < RH < 85%, non-condensed
Introduction Operator Manual

G1900
Genmega 2011 1.8
1.3 WARRANTY/SERVICE


MANUFACTURERS WARRANTY

Genmega, Inc. provides a limited one-year parts warranty for the G1900 series
ATM. Genmega guarantees your G1900 model ATM to be free from defects in
materials and workmanship.

The one-year parts warranty will begin 15 days from the shipping date.

WHAT IS COVERED:
Cash Dispensing Unit (CDU) and Cash Cassette
Receipt printer (SHU)
LCD module
Magnetic Card Reader (MCR)
EPP Keypad
Power Supply
Mainboard (CE)
Lock and locking mechanism **LIMITED 90 DAY WARRANTY**
Dial and Electronic locks will be covered by a limited 90-day warranty beginning
15 days from shipping date. Should the lock fail under normal use, Genmega will
replace the lock only. Services required to open the vault and or replace the lock
are at the expense of the ATM owner.

WHAT IS NOT COVERED:
Power cable and modem cable
Key lock and key
Plastic Bezels
Software upgrade
Receipt printer jam
Note jam
Forgotten password or combination of lock
Any damages from misuse, improper installation, and vandalism
Any damages from brown out or low power, lightning, or any other acts of God

Your distributor/dealer may offer an enhanced or extended warranty in addition to
the original manufacturers one-year warranty. Once the manufacturers warranty
has expired, all claims for warranty service must be resolved directly between the
distributor/dealer and the ATM owner.

OBTAINING SERVICE: If you have any problems or questions about your Genmega
ATM, your dealer or distributor is your primary contact for assistance/service. Your
manufacturers warranty is provided through your dealer or distributor.


Section 2: Installation Operator Manual


G1900
Genmega 2011 2.1
INSTALLATION

2.1 Genmega G1900 INSTALLATION

2.1.1 UNPACKING

Step 1

Upon receipt of your new Genmega ATM, check the box and packaging for any
damage. If you suspect any damage, mark the shipping receipt to indicate suspected
concealed damage. Do not discard the ATM packaging materials until you have
verified any shipping damage claim. Contact your distributor immediately if you see
any shipping damage. Its also advisable to take photos of any damage.

NOTE: You have 7 days from delivery to report any concealed damage. After 7 days
we are unable to process any shipping damage claims.

Step 2

Verify the contents carefully with the packing list to make sure all items listed are
included per your order. Notify your distributor of any shortages.


2.1.2 PHYSICAL INSTALLATION

To install the Genmega G1900 ATM, review the following steps:

Step 1

Place the system on a flat surface during installation. The system is top-heavy and
has a tendency to tip over. Be very careful when opening the top or bottom slide
trays or vault door prior to bolting down the ATM, it will be more likely to tip.

Step 2

Use the holes in the bottom of the vault to mark the floor or ATM location. Remove
the ATM before drilling the anchor holes. Anchors are not included with the ATM.

WARNING: Do not drill the holes through the vault. Dust from the drilling
will damage ATM components and void your warranty.

Due to variations in flooring and building codes, Genmega does not recommend a
particular size or type of anchor as each installation. Consult anchor manufacturers
instructions for proper installation. Maximum anchor diameter is .

Step 3

Place the G1900 ATM on top of the anchors and tighten. Note that over-tightening
the anchors can cause the vault to go out of square and make door operation
difficult. If this occurs, back off the anchors or use leveling bolts.
Section 2: Installation Operator Manual


G1900
Genmega 2011 2.2

Step 4

Open the vault door bezel with the key provided. See page 4.1 for Opening and
Closing instructions.

Step 5

Using the supplied combination (see lock manual for default combination), open the
Vault door. The default combination should be changed as soon as possible. Refer to
page 4.5 (dial) or 4.7 (electronic) for instructions on opening or changing the lock.



2.1.3 HARDWARE SETUP

Step 1

Verify the incoming power voltage (115/220V) for your
location and check the switch on the power supply of
the ATM (should be defaulted to 115V)





Step 2

Verify that the telephone line or internet connection for the ATM is in proper working
order. Make sure there is no voicemail on the line (pulse noise when you first lift the
receiver). NOTE Digital phones lines are not supported by this ATM.

Step 3

Open the security door. See page 4.1 for assistance.
















Use this key (2 included) to
open the top and bottom bezels
Cassette key
(fixed cassette)
Cassette key
(removable cassette)
Section 2: Installation Operator Manual


G1900
Genmega 2011 2.3
Step 4

Remove the cash cassette from its packing box (removable cassette dispensers
only). Fill the cassette or cash drawer with the appropriate amount of notes, and
carefully place it in the Cash Dispensing Unit. Place the appropriate denomination
label on the front of the cassette. See page 4.9 for instruction.

Step 5

Before closing the vault, thoroughly test the combination lock by locking and
unlocking the lock several times. It is much easier to diagnose potential lock
problems before shutting the door.

Step 6

Open the top of the ATM. Place the receipt paper in the Receipt Printer. The paper
prints only on one side (shiny side) always check the roll when you install paper.
Place the roll so that the coated side (shiny side) will be facing up. See page 4.12 for
paper loading instruction.

Step 7

Connect the Power cable and the telephone cable to the appropriate outlets on the
wall. Verify that the AC power outlet is grounded (3 prong plug).

If you are installing an optional topper sign, install the power cord through the top
housing and plug the topper into the open connector (white) located on the back of
the slide tray. Make sure the cable has enough slack to allow the slide tray to open
completely.

Step 8

Turn the power on and verify that all systems are operational. If any part on the
system or its programming is not operational, an error code will be displayed along
with instructions. If the error cannot be corrected, please contact your distributor for
help. If no error code is displayed, check the Error Summary.

Section 3: Programming Operator Manual


G1900
Genmega 2011 3.1
PROGRAMMING

3.1 INITIAL SETUP

3.1.1 ACCESSING THE OPERATOR FUNCTION


To access the Operator Menu, you do not need to hold down the 3 keys (CANCEL,
CLEAR, ENTER) and then press 1 2 3. Just press the following keys in order
[ENTER] [CLEAR] [CANCEL] [1] [2] [3].

Note: The Operator Function menu can only be accessed when the machine is either
in service (insert your card screen) or out of service. If the machine is attempting
to connect to the host or initializing, you will not be able to use the key commands to
access the Operator Function Menu.

If you have difficulty accessing the Operator Menu, power off the ATM and then
either open the vault door or remove the paper from the printer and power back on.
This will force the ATM to the Operator Menu.




Once you successfully completed the key
combination, you will be prompted to enter a
password. There are 3 levels of passwords.

Operator Password (allows access to basic
menu structure)
Service Password (allows access to basic
and diagnostic menus)
Master Password (allows access to all
menus including setup parameters)

You must press ENTER key after typing
the password!

Passwords are very important to maintaining
security for your ATM. Your
dealer/distributor will provide you with
default password information.



WARNING: Genmega highly recommends changing your passwords from default as
soon as possible. Keep all passwords safe and restrict access to non-authorized
personnel.

Passwords MUST be 6 digits in length, use of anything other than a 6 digit password
may cause the passwords to revert back to factory default.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.2



Shown the left is the complete Operator
Function menu, depending on which
password you entered (operators, service,
master) you may not see certain functions.
For example, if you use an operator password
you will not see the Host Setup button, as
you will not have access to that menu.



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.3
3.1.2 WHEN AN ERROR OCCURS

Step 1


When an error occurs, please press
[ENTER] [CLEAR] [CANCEL] [1] [2]
[3].

NOTE: If the machine goes out of service,
the error code will not always appear on the
screen. If you do not see an error code,
enter operator function and go to reports.
Look in the error summary for error codes.



Step 2


ENTER PASSWORD will be displayed. Enter
the Master, Service or Operator Password to
continue.

Contact your distributor for default
passwords.

Remember to press ENTER key after
typing password!


Step 3


When the screen is in current display, press
OP key to access the OPERATOR
FUNCTION.

Section 3: Programming Operator Manual


G1900
Genmega 2011 3.4
3.1.3 EPP KEYPAD





Genmega G1900 LCD display Function Key layout

This keypad layout and table below will help while learning how to input text and
numbers while programming your Genmega ATM. When in a text entry screen, the
F1, F3 and F5 keys are used to switch character maps between upper and lower case
as well as special characters.


0 1 2 3 4 5 6 7 8 9
+ Space A D G J M P T W
- Q B E H K N R U X
F1
Alphabet
Upper = Z C F I L O S V Y
+ Space a d g j m p t w
- q b e h k n r u x
F3
Alphabet
Lower = z c f i l o s v y
0 1 2 3 4 5 6 7 8 9
( [ { < , ! % : ?
F5
Number
Special ) ] } > . $ * ; /
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.5
3.2 HOST SETUP



The Host Setup menu provides access to the parameters necessary to connect the
ATM to the processor. Master Password is required to access most of these options;
however Service password allows basic access for troubleshooting purposes.

3.2.1 KEY MANAGEMENT

Access to Key Management requires entering a Secure Mode which engages
additional security measures (per VISA specification) to prevent Master Key
tampering. Make note of these changes as it does affect how keys are entered.

Entering Key Management requires two 6-digit passwords. By default these will be
000000 for part #1 and 000000 for part #2.



If a mistake is made entering the Secure Mode password, you will be prompted to
wait 30 seconds to reattempt.

NOTE: In compliance with PCI specifications, you must change the Secure Mode
Passwords from default before any Master Keys can be entered. After changing the
Secure Mode Passwords, you must exit completely from the Operator Menu, and
reboot the machine. After this step, you can enter Master Keys.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.6
Successful entry of both passwords will grant access to the Key Management screen.
From the moment the Key Management area is entered, a 5 minute timer begins. At
the end of 5 minutes, regardless of what you are doing (entering a master key for
example) the Key Management area times out and you will be taken back to the Host
Setup menu.


KEY MODE
This option sets the type of master key you will be loading (TDES, DES, MAC etc.)
Refer to Addendum C for Key Mode descriptions and instructions.

MASTER KEY INDEX
The ATM will hold up to 16 individual Master Keys. Check with your processor to find
if they are expected to be at a certain location. For example Coredata is always
installed at index #9, most other processors are installed at index #0 or #1. The
ATM will only use the key that the index is set to regardless of how many keys are
installed. To set the index simply press the button labeled Master Key Index and
then enter the number you want it set to (enter as a 2 digit number ... 00, 01, 02,
10, 11 etc.) press Enter when done. Press Check Master Key to see a list of
currently installed keys.

CHECK MASTER KEY
This will show the list of available master keys and their appropriate checksums. The
checksum is a 4 digit number calculated from the two 16-digit numbers of your
master key that provides a means to verify the master key is correct. When your
processor provides your Master Keys, they will also give you the 4 digit checksum. If
after entering your Master Key this checksum does not match, try reentering your
master keys or contact the processor.

EDIT MASTER KEY
This is where you enter your two 16-digit Master Keys (provided by your processor).
After pressing Edit Master Key, you will be prompted to enter an index where you
want this key stored. If you do not know which index to use, contact your dealer or
processor. Generally, you should use index 0 or 1 unless otherwise instructed.




Section 3: Programming Operator Manual


G1900
Genmega 2011 3.7
CHANGE PASSWORD
This allows you to set each part of the Secure Mode Password. As with the other
passwords used in the G1900, each must be a 6 digit number. If you change the
password and cannot remember it, you must clear RAM on the pin pad to reset.

NOTE: In compliance with PCI specifications, you must change the Secure Mode
Passwords from default before any Master Keys can be entered. After changing the
Secure Mode Passwords, you must exit completely from the Operator Menu, and
reboot the machine. After this step, you can enter Master Keys.

Entering Master Keys:
Use the chart below for entering Master Keys from the main pin pad.
Master Keys (or Key Management) cannot be entered from the optional Rear Service
Panel. Please see Appendix for specific Master Key instructions.







NOTE: The keypad above is EPP-B1 PCI / Interac certified EPP Device.
Previous models of EPP (PCI Only) had the Enter and Cancel keys reversed from
what is displayed above. If entering keys on the PCI only keypad, remember that
the Enter key is always F and the Cancel key is always D.







Section 3: Programming Operator Manual


G1900
Genmega 2011 3.8
3.2.2 SET TERMINAL ID NUMBER

Step 1
From the Host Setup Menu, go to Terminal ID. Terminal ID number is provided by
the processor and is individual for your ATM. It identifies your ATM on the network
and any transactions done on your machine will be linked to that number. This
number is obtained either through your dealer or processing company.




3.2.3 CONNECT TIMER

The connect timer is the setting which determines how long the machine will wait to
connect when trying to dial into the processor. Default time is 60 seconds. Lowering
this may improve connection speeds but at the risk of reliability.

3.2.4 SET ROUTING ID NUMBER

From the Host Setup Menu, go to Routing ID. The Routing ID is unique to each
processor and identifies the machine by processor. This number is obtained either
through your dealer or processing company.

NOTE: If using Standard 3 (Extended Messaging) Routing ID becomes COMS ID


3.2.5 SET HOST TELEPHONE NUMBER

Step 1
From the Host Setup Menu, go to Telephone Number.

Step 2
You can enter a Primary (Host Phone 1) and a Secondary (Host Phone 2) for the
machine to connect to the processor. These phone numbers are available from your
dealer or the processor (you can also reference the quick installation guide enclosed
with this ATM for numbers for the common processors).

Section 3: Programming Operator Manual


G1900
Genmega 2011 3.9
Step 3
Once you have selected Host Phone #1 or Host Phone #2 you will be prompted with
the following screen. Using the numbers on the keypad press the first number of
your phone number.


Step 4
Genmega always recommends using a dedicated, data-quality phone line for all ATM
installations, however if you are using a phone line that is dialing out through a PBX
type system (where you dial a number for an outside line), then you may insert
commas ( , ) to create a pause between digits.

For example if you have to dial a 9 to get an outside line try the following:
9,,18005551212
(the 800 number being an example)

NOTE: Entering anything other than a number or a comma in the host phone
number field will cause the ATM not to dial out. Make sure that Zeros and Os are
identified properly.

END

Section 3: Programming Operator Manual


G1900
Genmega 2011 3.10
3.2.6 HEALTH CHECK MESSAGE

Health Check is an option that will send a system status signal to your processor at a
set interval. Check with your dealer or processor to determine if they are prepared
to receive this type of messaging.

To Enable, simply access the menu from Host Setup. Use the Host Send button to
enable or disable the feature and the Message Send Interval button to set how often
the machine will broadcast its status (in hours).

NOTE: When using Standard 1 processing mode, an option for Extended Health
Check will appear. This option is for 4 cassette dispensers and is not used in the
G1900

3.2.7 REMOTE MONITOR

Remote Monitoring is the ability to dial into your ATM and send or retrieve
information using Genmega Remote Management Software (RMS).



RMS EN/DISABLE
This will allow the ATM to be monitored remotely.

Enable The ATM will answer incoming RMS calls.
Disable The ATM will not answer any incoming calls.

RMS SEND
This feature causes the ATM to dial out to a computer running RMS software to
report a malfunction, a fatal error or an out of service condition. Any time the ATM
goes out of service for longer than 3 minutes, it will call the number programmed at
Remote Phone #1 (and then Remote Phone #2 if Remote #1 is busy). It will
attempt this call 3 times. In order to use this feature you MUST have a PC (with a
modem and a dedicated phone line) running RMS software available 24 hours a day.

Enable The ATM will dial out to report out of service condition.
Disable The ATM will NOT dial out to report out of service condition.



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.11

RMS PASSWORD
Remote monitoring is protected by a password that is checked when incoming calls
from RMS occur. If the password does not match from an incoming RMS call, the call
will be disconnected. The default password for RMS access is 333333. To change the
password, press the password button and you will be prompted to enter your Master
password. After entering your Master password, you will be prompted to enter the
new RMS password (must be 6 digits) and then enter it again for verification. If you
ever forget the RMS password, press password and follow the procedure again.

REMOTE PHONE #1, #2

This is the number the ATM will call
if there is an out of service
condition. Press the button for
either number and enter the
number for the computer you want
the ATM to call.

Using the numbers on the keypad
press the first number of your
phone number. You can use the <,
> keys on the keypad to move
back and forth (to correct any
mistakes, or edit existing
numbers).

RING COUNT
This setting determines how many rings will elapse before the ATM will answer the
phone. While this can be used in situations where the ATM phone line is shared with
an additional device (like a fax or business phone) its important to note that setting
this value higher than 4 or 5 may result in monitoring software being unable to
connect.

3.2.8 TRIAL DAY TOTAL

Trial Day Total feature allows the ATM to complete a Day Total operation (without
actually closing out the machine) at a predetermined time each day. This is useful if
you are doing accounting of your ATM on a day-to-day basis. Your processor cuts off
its transactions each day at a set time. By enabling Trial Day Total at the same
time, your days balance should match the host. This information will appear as a
journal record, so you will need to access your journal to print or view the totals.
Your dealer or processor can provide you with the appropriate cut off time.

Trial Day Total Set Enables or Disables the function
Change Time Sets the time for the ATM to total itself



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.12
3.3 THE SYSTEM SETUP MENU




3.3.1 SET CLOCK

The Set Clock menu allows you to set the clock built into the ATM to the appropriate
date and time. You should set this for local time in the area the machine is to be
installed. Note that with each transaction you will see also see a Host time, this is
the local time for the processor and may be different from local time at the ATM. To
set the clock, simply press the Set Clock button and press the key corresponding to
the function you want to set (month, day, year, etc.)

NOTE: The ATM will not automatically adjust for daylight savings time. You must set
this manually if you wish it to change.



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.13
3.3.2 OPTIONAL LANGUAGES

The Genmega G1900 ATM supports 3 on screen languages: English, French &
Spanish. The optional languages will display on the welcome screen, then the
customer will be prompted to choose a language to be used for the rest of that
transaction.

NOTE: The optional languages are displayed on screen only and do not print on the
receipt or journal. Receipts, journals and operator menus are always in English. To
enable or disable a language, simply press the button next to the language you wish
to change.






Section 3: Programming Operator Manual


G1900
Genmega 2011 3.14
3.3.4 ISO 1, 3 EN/DISABLE

The ISO Tracks are the three tracks available for the card swipe head to read. The
ATM is already defaulted to read from Track #2 (which is why its not shown). This
parameter should not be changed. Changing the ISO tracks can cause the ATM to
not read cards properly.





3.3.5 CHANGE PASSWORDS

The ATM uses three passwords to provide security to the operator menu system.
These are Operator, Service and Master.

Operator Password (allows access to basic menu structure)
Service Password (allows access to basic and diagnostic menus)
Master Password (allows access to all menus including setup parameters)

The operator password can be changed by anyone with the current operator
password. The service and operator passwords can be changed by anyone with the
service password. The master password can only be changed by someone with the
current master password. Any password can be changed using the master
password.

For example, if you have lost the operator or service password, you can use your
master password to change them. Simply enter the master password when it
requests the operator or service password and then enter the new password.

You are required to change the master password from default before the ATM can go
in service.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.15


To change a password, press the button for the appropriate password. You will be
prompted to enter the new password and then enter it a second time to verify. If
you forget your password please contact your dealer or distributor for service.




NOTE: All passwords MUST be 6 digits. If you use a password that is less than 6
digits, the passwords may default back to factory if the machine is power cycled. If
your customer wants a 4 or 5 digit password, add zeros to the end to make it 6
digits.

WARNING: The ATM will NOT go into service with the default master password.
You must change the master password from default! If you attempt to go in service
with the default master password, you will receive a F0016 Error, which will notify
you that the master password has not been changed.

It is critical that you do not set the same password for each of the three levels. If
you duplicate the password, the lower level permissions will be the default.
For example, if the Operator Password is set to 123456 and you also set the Master
Password to 123456, then when you log in with that password, youll only have
access to Operator level commands. In this example, youd have to change the
Operator Password to something else, and then 123456 would then allow you to log
in as Master. If you forget the passwords, youll need to reload the AP software to
reset.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.16
3.3.6 DEVICE SETUP

The Device Setup menu provides options to adjust parameters of the various
peripherals. Under normal circumstances you should not need to make changes to
these parameters. The default settings are optimized for your particular machine.
Genmega recommends only using these tools under the direction of an Authorized
Service Provider (ASP) or Genmega Technical Support.




3.3.6.1 SPR SETUP

The SPR Setup allows you to set the maximum column width for the receipt printer.
Default is 40 characters.











Section 3: Programming Operator Manual


G1900
Genmega 2011 3.17
3.3.6.2 MODEM SETUP

The Genmega G1900 series use an onboard 56K modem. The modem is preset at
the factory for optimal use. Changing these settings can cause your machine to not
communicate or may slow communication speeds. Do not make changes to the
modem settings.




MODEM SPEED
This sets the speed at which the modem will begin communication with the host.
The default speed is 2400. Most processors are only using 2400 baud modems, so
setting this value higher may not increase modem performance.

Available settings : 1200, 2400

MODEM SOUND
This will allow the modem to output its dial-out and handshaking through the
external speaker. This is useful when testing the modem to hear if its dialing
properly.

Available setting: OFF , ON


3.3.6.3 MCR (Card Reader) SETUP

The Genmega G1900 can be equipped with an optional EMV compliant card reader.
If the setting is not correct, the card reader will not work at all. After setting the
MCR to the appropriate type reader, back out of the menus and then reboot the
machine for the changes to take effect. Since these different card readers use
alternate ways to communicate, its necessary to reboot.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.18
3.3.6.4 CDU SETUP

The CDU (Cash Dispensing Unit) or Dispenser contains programming relative to its
application and country of destination. This programming does not need to be
altered, however in the event that the dispenser looses its factory programming the
CDU Setup application can correct any problems. NOTE: Incorrect programming of
the dispenser will cause the machine to go out of service.





3.3.7 SET REBOOT TIME

The G1900 contains a feature which automatically reboots the machine at a 24
hour interval. By default this will occur at 03:00 am. This adjustable in 1 hour
increments.








Section 3: Programming Operator Manual


G1900
Genmega 2011 3.19
3.3.8 SERIAL NUMBER

The serial number is a unique number programmed into your machine at Genmega.
It not only identifies your machine for warranty purposes, but also for remote
monitoring using Genmega RMS. The first 4 digits refer to the model type, and the
last 6 is production cycle. By default this number is programmed from the factory
and we do not recommend changing it. However if you need to clear NVRAM for any
purpose this number will be deleted. If you wish to re-enter the serial number, youll
find it on the sticker located inside of the upper cabinet.


Keeping the serial number in the proper format will prevent problems when trying to
connect for remote management.



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.20
3.4 CUSTOMER SETUP MENU

The Customer Setup menu controls surcharge information, BIN lists, receipt options,
advertisements and keypad lighting.




3.4.1 CHANGE MESSAGE

The Messaging options for the ATM are a welcome message and a receipt header
message. The Welcome message allows line of 35 characters, which will appear at
the top of the main screen (above the center graphic). The receipt header is up to 4
lines of 25 characters, which will appear at the top of each receipt.



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.21

WELCOME MESSAGE

Once you have selected Welcome
Message from the Change Message
Menu, you will be prompted with the
following screen.



RECEIPT HEADER


Once you have selected Receipt Header
from the Change Message Menu, you will
be prompted with the following screen.
See the above instructions for navigating
this menu.



Section 3: Programming Operator Manual


G1900
Genmega 2011 3.22
3.4.2 BIN LISTS

BIN numbers are card numbers that you have preset with your processor to not be
surcharged. You must set this up with your processor, who will then give you
numbers to enter in the list. These numbers will reference cards that you wish to
not be charged a surcharge for transactions. The ATM will hold up to 96 numbers (0-
95).

If you need more BIN numbers, there is a file that can be created to load several
thousand more numbers. See Appendix for instructions.

Step 1


To enter the BIN numbers select BIN List
from the Customer Setup menu. The list
can hold 2 banks of 30 numbers for a total
of 60. Bank 0 and Bank 1. Press the
OTHER button to switch between the banks.



Step 2


To add a number, press ADD and input the
BIN number with the keypad. To remove,
press REMOVE and type in the BIN number
you wish to delete from the list.

Press OTHER to switch between Bank 0 and
Bank 1.
Step 3
If you wish to view the contents of the BIN list, use the Print All Setup report. From
the Operator Function Menu, go to Reports, then Print All Setup. Any numbers
added to the BIN list will be visible from this report. NOTE: Numbers loaded via the
extra BIN file will not display on the Print Setup or any other report.

END


Section 3: Programming Operator Manual


G1900
Genmega 2011 3.23
3.4.3 OPTIONAL FEATURES



The G1900 ATM offers several optional functions to improve performance and keep
the ATM functional in the event of a paper problem (jam, out of paper etc.)


LOCATION NAME
Adding a name to this location will print the name entered onto the journal records
and print all setup. This is purely a convenience option and is not required.

SELECT RECEIPT
This feature allows the ATM to complete transactions even though it may not be able
to dispense a receipt. If the ATM experiences a paper jam, or runs out of paper, the
customer will be asked if they would like to complete the transaction even though
they will not receive a receipt. If the customer answers Yes, the transaction will
continue. Following the transaction the customers information (what would have
appeared on the receipt) will display on the screen. The ATM will continue to operate
without use of the printer until someone accesses the Operator Function menu. At
that time the error must be corrected before the ATM will go back into service.

To enable the option, press Select Receipt, the lower portion of the screen will
display the options status.
TRANSFER TO CREDIT
Some networks do not allow customers to transfer funds to or from their credit
cards. By enabling / disabling this option you will add or remove the option button
from the customer menus. Check with your Distributor / Processor as to whether or
not they support fund transfer to or from credit cards. NOTE: If your network does
not support such transfers and you leave the option enabled, the customer can
choose it from the menu however the network will not authorize the transaction.

CHECK BALANCE
Enabling this option will ask each customer if they would like to check their balance
before each transaction.


Section 3: Programming Operator Manual


G1900
Genmega 2011 3.24
3.4.4 CHANGE PROCESSOR

Host Processor selection changes the communications protocol to specifically match
your particular processor. In most cases this is set at the factory when your
machine is ordered, however in the event that the machine needs to be
reprogrammed for a new processor, it may be necessary to change the processor
mode.

NOTE: You do NOT need to clear NVRAM to access the Change Processor menu

To access the Host Processor mode, enter the Customer Setup menu using the
Master Password.



Communication modes are:

Modem dial up (uses on board modem)

TCP/IP Standard TCP/IP
VISA FRAME TCPIP
ACK CONTROLLED TCPIP
SSL PASS THROUGH
SSL LENGTH PREFIX W/O ETX
SSL LENGTH PREFIX WITH ETX

** See page 3.31 for TCP/IP Setup Instructions **

Use the Message Format button to select the appropriate Host Processing Mode.
Available formats are:

Standard 1
Standard 2 (CSP200 Emulation)
Standard 3 (Extended Message)
EPS

If Standard 3 is selected, youll see a Standard 3 Options button which will give
access to the Extended Messaging options.

Contact your distributor or processor for which mode is appropriate.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.25
3.4.5 SURCHARGE MODE

The Surcharge menu displays the current rate at which customers are charged per
transaction, the person or account that the surcharge funds are sent to and whether
or not the option to surcharge is enabled or disabled. The information programmed
here must match the information given to the processor at the time the account was
created. Because of features like Percentage Surcharge that require the surcharge
value to be set at the ATM, its possible for the ATM to override what the processor
expects to surcharge (or not surcharge customers at all) if these settings are not
correct.

Please review the following setting carefully and instruct your operators on the risks
involved in changing surcharge settings.




To set the surcharge parameters begin by entering the Surcharge Mode menu from
the Customer Setup menu. The bottom of the screen displays the current status of
each surcharge parameter.


DISABLE/ENABLE
This button toggles the surcharge option on and off.

AMOUNT
To set the surcharge amount, press the amount button and type the dollar amount
using the main keypad. Next set the decimal point using the Enter key on the
keypad. Then type the cents using the keypad and finally press Enter to finish.


Section 3: Programming Operator Manual


G1900
Genmega 2011 3.26
PERCENT
This allows you to set the surcharge amount as a percentage of the overall amount
the customer is withdrawing per transaction. Check with your processor to make
sure that they support this function.

SURCHARGE OWNER



The surcharge owner can be up to 25
characters long. This owner name will
appear at the bottom of each transaction
receipt.



WARNING: If you set the percentage surcharge mode from Greater to Lesser and
leave the percentage value at 0%, then customers will not be surcharged.

Example - Surcharge set as follows:

Surcharge $1.50 or 0% whichever is Greater = customer is charged $1.50.
Because $1.50 is a greater value than 0.

Surcharge $1.50 or 0% whichever is Lesser = customer is not charged at all.
0% is lesser than $1.50.

Section 3: Programming Operator Manual


G1900
Genmega 2011 3.27
3.4.6 GRAPHICS

The Genmega G1900 is capable of displaying up to 8 customized graphic screens.
These graphic files are created on a computer and then downloaded into the ATM
either directly at the ATM using a SDRAM card or by using the Genmega Remote
Management Software (RMS). When the advertisements are loaded and enabled
they will rotate in order while the ATM is waiting for a transaction and also while the
transaction is processing. There is a timer, which allows you to set a delay before
switching to the next graphic screen. Please see Appendix D at the end of this
manual for detailed instructions for creating advertisements.



Step 1


Enter the Graphics menu and choose
Advertise enable or disable each
loaded graphic.



























Section 3: Programming Operator Manual


G1900
Genmega 2011 3.28
3.5 TRANSACTION SETUP



3.5.1 DISPENSE LIMIT

The dispense limit is the maximum amount of money a customer can withdraw in a
single transaction. The ATM will dispense a maximum of 40 notes per transaction.
So the dispense limit can be a maximum of 40 times the denomination of notes your
using.

For example:

If you are dispensing $10 bills the maximum dispense limit is $400
If you are dispensing $20 bills the maximum dispense limit is $800
Maximum is $900 (using either $50 or $100 bills)

To set the dispense limit, press the Dispense limit button and then enter the number
using the keys on the main keypad. Press Enter key to set the value.
















Section 3: Programming Operator Manual


G1900
Genmega 2011 3.29
3.5.2 DENOMINATION



The Denomination is the type of bill that each cassette will be dispensing. The ATM
offers a second cassette as an option. This second cassette can be programmed to
dispense notes, it can also dispense a preset number of bill sized coupons with each
transaction and finally it can dispense a value coupon, where you would set the
value of the coupon and the customer could purchase this using their card.

WARNING: Any change to the denomination will cause all master keys to be
deleted from the EPP keypad. If you attempt to enter the denomination setup menu,
you will be prompted and warned that continuing will cause all master keys to be
erased. The purpose of this is to prevent unauthorized changes to this critical
setting.

When programming the ATM, make sure to make any changes to the denomination
setting BEFORE you program master keys. Once keys are erased, they cannot be
recovered. New master keys will have to be loaded.









To set denomination on the first cassette, press the First CST Denomination button
and then using the main keypad enter the type of bill. Options are $1, $5, $10, $50
and $100.

To set denomination on the second cassette, press the Second CST Denomination
button and then using the main keypad enter the type of bill. Options are $1, $5,
$10, $50 and $100.




When programming the ATM, make sure to make any changes to the
denomination setting BEFORE you program master keys.

Once keys are erased, they cannot be recovered. New master keys will
have to be loaded.
Section 3: Programming Operator Manual


G1900
Genmega 2011 3.30
3.5.3 FAST CASH

Fast Cash amounts are presented to the customer if they choose a Withdrawal
transaction. These amounts appear on screen as an easy method of selecting how
much cash they wish to withdraw for that transaction. The amounts must be
multipliers of the denomination amount.

For Example:

If your dispensing $10 bills then you can use $10, $20, $30, $40, $50 etc.
If your dispensing $20 bills then you can use $20, $40, $60, $80, $100 etc.

To set the fast cash amounts, select Fast cash from the Transaction Setup menu and
then choose from the 6 possible keys to program. Select a button and then enter
the value from the main keypad. Press Enter to confirm the setting.





















Section 3: Programming Operator Manual


G1900
Genmega 2011 3.31
3.6 TCP/IP SETUP

TCP/IP Setup is done in several menus. First you need to specify TCPIP from the
Communications Menu: [See page 3.24] Check with your processor for which
protocol they are expecting.

Operator Function Menu Customer Setup Change Processor Communication
Change this value to SSL Pass Through (or other depending on processor)

Once you change from Modem, to one of the TCP/IP settings, several other menus
change to support various network functions.

For Example:
Operator Function Menu Host Setup Processor IP and Address Port

Here you will set the Host Processor IP (or URL) address and port. For some
processors an IP address (example = 121.212.1.21) is used and for others youll
enter a URL address (example = trans.mybank.processor).

In addition to the address, there will also be a port setting (example = 6543)




Configuration Schedule allows you to force the ATM to update configuration with the
host upon boot up. You might use this command if the terminal gets consistent Key
Errors and you want to force download of a new working key.












Section 3: Programming Operator Manual


G1900
Genmega 2011 3.32
The ATM IP information is set using the menu found at:

Operator Function Menu System Setup Device Setup ATM TCP Setup

This menu is only active if you have the communication mode set to TCP
[See page 3.24]




These settings will be dependant on the network connection available at the location
where the ATM is deployed. It may be necessary to contact the ISP or Network
provider for the location to determine how this should be set.

TCPIP Mode: DHCP or STATIC IP

NOTE: a Static IP address will be required if you intend to use RMS monitoring
software with this ATM.

Change IP Address: Enter the ATM IP address here (for static IP) or this field will
automatically populate if DHCP is used to obtain an IP automatically.

Subnet Mask and Gateway: These values will be provided by your ISP/Network
Provider and refer to the Router that youll be connecting to.

Ping to Gateway: This is a test which will ping the Router and verify communication
between the ATM and the network. If this test fails, then the ATM will not reach the
host.

Ping to Host: This test attempts to verify communication with the IP address or URL
that is programmed in the Processor IP Address menu. Note that most processors
or switches do not allow pinging for security reasons.








Section 3: Programming Operator Manual


G1900
Genmega 2011 3.33
TCPIP Troubleshooting

When trying to connect your ATM to the internet, there are two error codes which
can occur.

2511 This means that the ATM sent a request, however nothing responded.
Typically this means the ATM cannot get out on the internet.

To test this, we suggest replacing the Host IP number with one from a common
public website like Google [74.125.224.50] or Yahoo [98.137.149.56]
Those IP addresses will allow pinging. So after entering it, you can go to the Ping to
Host button in the TCPIP setup menu and check that you can ping google or yahoo.

If you are unable to ping those sites, the ATM cannot see the internet.

DSL Modems some cheap DSL modems will not allow the ATM to use DHCP and
obtain an IP address, even though other computers or devices can. This is usually
shown in the ATM TCPIP Setup Menu, where the Gateway value is 0.0.0.0. If this
occurs, you will need to get a broadband router to place in between the ATM and the
DSL modem. This will allow the ATM to get an IP address from the router, rather
than the DSL modem.

2514 This means that the ATM sent a message and received an unexpected or
incorrect response. Typically this means that one or more settings on the ATM are
incorrect and should be compared against what the processor is expecting.

Network Cable:

When you connect the internet (Ethernet) cable to the ATM you should see a steady
link-light (green) on the and also a flashing data-light (amber) as shown below.

Make sure you use a network patch cable and not a cross-over cable.






Section 4: Operation Operator Manual


G1900
Genmega 2011 4.1
OPERATION

4.1 OPENING AND CLOSING

4.1.1 Opening the Security Door
Step 1


Turn the vault bezel key clockwise to open
the lower vault bezel. The key will remain
in the lock after you turn it.


Step 2


To unlock the Dial or optional Electronic
Lock (see the manufacturers lock manual
included in the open me first box for default
combination) and then refer to Section
4.1.6 for lock instructions


Step 3


Turn the security Door Handle counter-
clockwise; then pull the security door to
open.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.2
4.1.2 Closing the Security Door

Step 1


With the security door handle turned
counter-clockwise, close the security door
and turn the security door handle clockwise
until it is locked. The electronic lock
mechanism will lock itself once the T-handle
has returned to its vertical position. The dial
combination lock must be turned counter-
clockwise to lock.


Step 2


Check the T-handle to make sure the lock has
locked itself.



Step 3


With the security cover key turned clockwise,
close the security cover and urn the security
cover key counter-clockwise until locked.
Remove the key when it is locked.




Section 4: Operation Operator Manual


G1900
Genmega 2011 4.3
4.1.3 Opening the top Bezel

Step 1


The upper bezel lock on the Genmega 1900
is located on the back side of the top of the
machine. Insert the Bezel key and turn it
clockwise to open.

(Optional Topper Shown)


Step 2


With the Front Panel key turned, pull the
Front Panel outward.





Section 4: Operation Operator Manual


G1900
Genmega 2011 4.4
4.1.4 Closing the top Bezel

Step 1


Push the Front Panel slowly until it is against
the lock mechanism. Note: you must unlock
the top bezel lock before the bezel will close
all the way.


Step 2


To lock the top bezel, turn the Bezel key
counter-clockwise until the key can be
removed.

(Optional Topper Shown)





Section 4: Operation Operator Manual


G1900
Genmega 2011 4.5
4.1.5 Operating and Changing the Combination Lock (non-electronic)

Before operating the lock or changing the combination,
READ THE INSTRUCTIONS THOROUGHLY.

At the top of the dial ring, an index is provided
for normal dialing and opening. At the side of
the opening index (11 o'clock), a changing index
is provided for use only when setting a new
combination.

This is a precision lock; therefore, extreme care
must be used to align the combination number
with the index.

Turn the dial slowly and steadily. If after turning
the correct number of revolutions, any number is
turned beyond the index, the entire series of
combination numbers must be re-dialed. DO
NOT TURN BACK TO REGAIN A PROPER
ALIGNMENT WITH THE NUMBERS. Each time a
selected number is aligned with the opening index, a revolution is counted.

Please contact your distributor or consult manufacturers lock manual for
default lock combination

Step 1
Turn the dial to the LEFT, stopping when the first number is aligned with the opening
index, the FOURTH time.

Step 2
Turn the dial to the RIGHT, stopping when the second number is aligned with the
opening index, the THIRD time.

Step 3
Turn the dial to the LEFT, stopping when the third number is aligned with the
opening index, the SECOND time.

Step 4
Turn the dial slowly to the RIGHT until the bolt retracts.


TO LOCK

Turn dial to the LEFT at least four full revolutions.


CAUTION: Before closing the vault door, try the new combination several times
using the opening index.
Changing Index
Opening Index
Section 4: Operation Operator Manual


G1900
Genmega 2011 4.6
Changing to a New Combination

To make up a new combination, select 3 sets of numbers of your own choosing.
DO NOT USE NUMBERS BETWEEN 0 AND 20 FOR YOUR LAST NUMBER
DO NOT USE NUMBERS ENDING IN 0 OR 5
DO NOT USE NUMBERS IN A RISING OR FALLING SEQUENCE (e.g. 35-50-75)

Insert Figures (3)

Step 1
Using the changing index, dial the existing combination as explained in paragraphs
1-3 above.

Step 2
Hold the dial with the last number at the changing index and insert the changing key
in the keyhole in the back of the lock. Insert the key until the wing is entirely inside
the lock and comes to a positive stop.

Step 3
Turn the key one-quarter turn to the RIGHT or clockwise. With the changing key in
this position, turn the dial to the LEFT; stopping when the first number of the newly
selected combination aligns with the changing index the FOURTH time.

Step 4
Turn the dial to the RIGHT, stopping when the second number is aligned with the
changing index, the THIRD time.

Step 5
Turn the dial to the LEFT, stopping when the third number is aligned with the
changing index, the SECOND time. Holding the dial in this position, turn the
changing key back to the LEFT or counter-clockwise and remove it. The new
combination you have chosen is now set in the lock.


WARNING: NEVER INSERT THE CHANGING KEY IN THE LOCK WHEN THE COVER IS
REMOVED. ALWAYS BE CERTAIN THAT THE WING OF THE CHANGING KEY IS
ENTIRELY WITHIN THE LOCK BEFORE TURNING THE KEY. IF AN ERROR HAS BEEN
MADE IN SETTING A NEW COMBINATION, WE SUGGEST THAT AN ACCREDITED
LOCKSMITH BE CONTACTED.










Section 4: Operation Operator Manual


G1900
Genmega 2011 4.7
4.1.6 Operating and Changing the Electronic Lock

Before operating the lock or changing the combination,
READ THE INSTRUCTIONS THOROUGHLY*.

*See manufacturers lock manual included in the Open Me First Box


The LA GARD LG Basic series electronic lock uses a
touch key pad for all lock functions.

Power is supplied to the lock via a standard 9-volt
Alkaline battery which contained within the external
portion of the lock. The lock will warn of low voltage by
repeatedly beeping.



TO UNLOCK FROM DEFAULT COMBINATION

Step 1
Press the default combination one button at a time, (see lock manual or consult your
dealer for default combination). A beep is heard following each key press.

Step 2
If the combination is entered correctly a double-beep is heard and the internal lock
solenoid will click indicating that the lock is open and the vault handle my now turn.

Step 3
If the wrong combination is entered a triple-beep will be heard. If the correct
combination is not entered within 4 consecutive attempts a 5 minute delay or lock
out will begin. During this time, the led at the 2 oclock position on the face of the
lock will flash at 10 second intervals. In addition any key press will respond with a
triple-beep. Once the 5 minutes has elapsed, 2 more consecutive failed attempts will
restart the 5 minute timer.



WARNING: While orienting yourself with the lock, making changes to the lock
programming (including changing the combination) ALWAYS work with the vault door
open. Do not close the vault until the lock has been thoroughly tested.

Genmega does NOT program a master combination!
Section 4: Operation Operator Manual


G1900
Genmega 2011 4.8
Changing to a New Combination

NOTE: Combination is required to be 6 digits. Combinations of less than 6 digits will
not work.

Step 1
Begin by entering six zeros. ( 000000 )

Step 2
Enter the existing combination one time

Step 3
Enter the new combination twice. As each six digit sequence is entered, a beep is
heard.

Step 4
If the procedure is not performed correctly, at the end a triple-beep is heard and the
lock will revert back to the previous combination.


The LG Basic series lock includes several options including multiple user / manager
passwords. Please consult the LA Gard manual included in the Open Me First box
for instructions.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.9
4.2 CASH OPERATIONS

4.2.1 Adding Cash to the Cassette (TCDU)

Step 1


Open the Security Door. (Please see 4.1.1
OPENING/CLOSING THE SECUIRTY DOOR.)



Step 2


For Genmega 1900 with a fixed cassette
dispenser (TCDU) use the following steps.
For machines equipped with the removable
cassette dispenser (SCDU or MCDU) please
continue to Section 4.2.3.

With the security door open, remove the slide
tray screw and slide the dispenser all the way
out.


Step 3


Insert the key into the top of the reject bin
and lift up to access the cash tray.



Section 4: Operation Operator Manual


G1900
Genmega 2011 4.10

Step 4


Push the slide the push plate located inside
the cash tray back (towards the rear of the
dispenser) until it latches in place.



Step 5


Press on the latch bar to release the push
plate against the notes.

TIPS ABOUT ADDING BILLS:

1. Fan the notes so that the notes are not sticking together.
2. Remove all the notes with holes or notes that are torn.
3. Unfold the folded notes.
4. Place all the notes correctly.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.11
4.2.2 Emptying the Reject Bin

Step 1


Insert the key into the reject bin lock and
turn to unlock.


Step 2


Pry back on the plastic tabs at the base of the
arrow stickers on each side of the reject bin.
Lift the reject bin lid.


Step 3


With the reject bin open, remove any notes
and then close the top. Turn the key to lock
the reject bin in place.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.12
4.2.3 Adding Cash to the Cassette (SCDU or MCDU)

Step 1


Open the Security Door. (Please see 4.1.1
OPENING/CLOSING THE SECUIRTY DOOR.)



Step 2


With the security door open, remove the
cassette. Lift up on the handle while
supporting the bottom of the cassette while
removing.


Step 3


To avoid damage, never use force while
removing or installing the cassette. If
anything beyond gentle force is required
while handling the cassette, contact your
service personal.



Section 4: Operation Operator Manual


G1900
Genmega 2011 4.13

Step 4


Open the cassette using the key shown
in Section 2 (page 2.2)



Step 5


Pull back on the cash plate and load the
bills against the rollers at the back of
the cassette. If you pull the cash plate
back all the way it will lock at the front
of the cassette. Push the green lever on
the cash tray to release.

TIPS ABOUT ADDING BILLS:

5. Fan the notes so that the notes are not sticking together.
6. Remove all the notes with holes or notes that are torn.
7. Unfold the folded notes.
8. Place all the notes correctly.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.14
4.2.4 Emptying the Reject Bin

Step 1


To open the reject bin, pull back on the tabs
located on the sides of the reject bin door.


Step 2


Remove any notes found in the reject bin and
close the door by pressing it shut.
Remember to include the number of bills
found in the reject bin when settling the
cassette.



















Section 4: Operation Operator Manual


G1900
Genmega 2011 4.15
4.2.5 Loading the Receipt Paper

Step 1


Open the top Bezel. (See 4.1.4 Opening
the top Bezel.)


Step 2


Place the paper onto the supplied spindle
with the Coated Side Out as shown in the
picture. Feed the paper out through the
back, where it will curl back under the
tension bar.


Step 3

Prepare the new paper roll. Note below.

NOTE:
1. Make sure the roll is in its proper roll form. (A deformed roll may cause jamming
problems.)
2. When replacing the new roll, make sure the end of the roll paper is clean cut.









Section 4: Operation Operator Manual


G1900
Genmega 2011 4.16
Step 4


Feed the paper over the bar behind the roll
and under the spring loaded tension bar.
Slide the paper through the guides. The
paper will not feed until the machine is
initialized (powered on). If the paper does
not feed, make sure the paper is all the way
in the loading guide. Also make sure the
roller assembly is closed (see below)


Step 5


The roller assembly can be opened by
pressing down on the green lever in front of
the printer.


Step 6


To close the roller assembly, lift up on the
rollers. The roller assembly must be
completely closed before the printer will
operate. Press up on the roller assembly
rather than on the green lever to close.

When finished loading paper, close the top
bezel and remove the key.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.17
4.3 SETTLEMENT MENU



Choose Settlement from the Operator Function menu. This menu controls how many
bills have been added to the ATM as well as generating Day total and Cassette total
reports.

ADDING CASH

Step 1
Press the Add Cassette button.

Step 2
Using the main keypad, enter the number of bills added to the cassette (not the
amount of money).
Step 3
Press the enter key when finished to set the amount.


If you make a mistake and wish to zero out the current number of bills, youll need
to press Cassette total to do this. Anytime you press Add Cassette you will be
adding on to the current number of bills already programmed.

For example:

There are 50 bills in the cassette and in the settlement menu it says Current # of
Bills = 50. You wish to add 25 more bills to the same cassette, you press Add
Cassette, then type 25 from the keypad and press enter. The current number of bills
will now be 75.

Now say there are 50 bills in the cassette and in the settlement menu it says Current
# of Bills = 50. If you wish to remove 25 bills from the cassette, press Cassette
Total. This will return the number of bills in both cassettes to zero and print a
receipt showing remaining bills and loaded bills. Now press Add Cassette and enter
25 from the keypad, press enter to set. The current number of bills will now be 25.

Section 4: Operation Operator Manual


G1900
Genmega 2011 4.18
DAY TOTAL

The Day Total function keeps a running
total of the ATMs transaction activity.
When you press day total, the ATM will
print a report showing transaction totals
starting from the last time a day total
was done until now. At the same time,
the 1900 will dial into the Host Processor
and retrieve their totals for the same
time period. To the left is an example of
a Day Total Report. Once the report is
printed, the ATM will reset these values
to 0 and begin recording from this point.

One thing to keep in mind when doing a
Day Total is that the Host (or Processor)
cuts off their transactions at a certain
time every day. If you do a Day Total
report before or after the processor has
done their cut off, you may see
discrepancies between what the terminal
had reported and what the host reports.

To avoid this, talk to your dealer and find the approximate cut off time for your
processor. Try to do your day totals at this same time. Remember that if you do not
match your processor, the missing transaction(s) will usually appear on the next
total. If you are unable to do your Day Total at the same time each day you can
program the machine to do a Trial Day Total automatically (see section 3.2.7).

After the Day Total has printed you will be prompted on the screen that the total has
printed and to press the Enter key to return to the menu.

Section 4: Operation Operator Manual


G1900
Genmega 2011 4.19
CASSETTE TOTAL

The Cassette Total function prints a
report detailing the number of bills
that have been loaded into the
cassette and how many bills were
dispensed, either to the customer,
the reject bin or used during a
dispenser test. This report will show
totals from the last time you ran a
Cassette Total to the current date.
After the Cassette Total has been
printed, all the values will reset to
zero.

NOTE: Running a Cassette Total is
the only way to clear the Settlement
value back to zero bills. After the
Cassette Total has printed you will be
prompted on the screen that the total
has printed and to press the Enter
key to return to the menu.

TRIAL CASSETTE TOTAL / TRIAL DAY TOTAL
These reports are identical to pressing Day Total or Cassette Total, the only
difference being that they will not zero out the amounts. This report is useful if you
wish to know current Total statistics without closing them out. To run these reports,
simply press the button and the report will print. Press Enter when finished to return
to the Settlement Menu.

NOTE: Trial Day Total can be set to process automatically at a preset time. See
Section 3.2.7 for information on automated scheduling of a Trial Day Total.



Section 4: Operation Operator Manual


G1900
Genmega 2011 4.20
4.4 JOURNAL MENU



The Journal is an electronic record of all transactions, errors and some programming
changes made to the ATM. Depending on the size of each entry, the memory can
hold up to 40000 records. Each entry into the journal is indexed with a 5-digit
sequence number starting with <00000>. Once the journal memory has reached its
maximum limit, it will begin to overwrite the oldest entries. You will not be warned
of this, therefore it is critical to make sure to download or print your journal often
enough to avoid loosing records.

The journal can be printed from the ATM in two different methods, Standard and
Condensed. Standard will give complete information for each transaction (basically a
copy of the customers receipt), whereas the condensed print will only show sequence
number, date, time, what type of transaction and then amount requested / amount
dispensed (in case of withdrawal).

PRINT JOURNAL

Step 1
To print the journal, press the Print Journal button.

Step 2
You will be prompted to choose standard (PRINT) or condensed (CONDENSED
PRINT).

Step 3
The ATM will then print all journals in memory up to the last time you printed a
journal. Each time you print a journal a marker is set at that point. The next time
you print the journal, the ATM will print from that marker to the current time.

END


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.21

LAST X PRINT
The Last X Print option allows you to bypass the marker set when printing a journal
and go back to recover an older record (so long as the record still exists in memory).
For example, you print a journal and it includes sequence numbers <00001> to
<00100>. If you wanted to go back and reprint journal number <00080> you would
need to do a Last X Print for 20 records (100-20=80) this would give you records
100-80. To do a Last X Print, press the button and then enter a value of how many
records you wish to go back.

CLEAR TRANSACTION SEQUENCE NUMBER
This function will reset the journal sequence number back to <00000>. This may be
useful if you switch processing or switch Terminal ID numbers and want to keep new
records.


VIEW JOURNAL

View Journal allows you to visually
inspect the journal records. Press
the View Journal button and you
will see the screen to the left.

Use the Arrow keys on the main
keypad to scroll through the
records. You can also use the
buttons next to +50 and -50 to go
forward or backwards 50 records
at a time. Use the Enter button to
print the journal entry currently
displayed. Press Cancel to exit
this menu.

CLEAR JOURNAL
Clear Journal sets the current journal marker to the most recent journal recorded. It
does not delete the journal from memory. For example: You currently have 100
entries in your journal, you press Clear Journal. Now if you press Print Journal,
nothing will happen because there are no current journal entries, however if you
used Last X Journal, you could enter 100 and get all the records.


Section 4: Operation Operator Manual


G1900
Genmega 2011 4.22
4.5 REPORTS MENU



The reports menu provides statistical information as well as troubleshooting and
error information.

ERROR CODE


If the machine is out of service, and
you are unfamiliar with the error code
being displayed (or none is displayed),
this screen will provide error
descriptions as well as corrective
action for the currently displayed
code. Press the Error Code button to
enter this screen. You can also use
you left and right arrow keys on the
main keypad to scroll through all the
possible error codes and descriptions
the ATM can report. To the left is an
example of an Error Code screen.


S/W VERSION
This screen provides the current revisions of software used in your ATM. This
information may be used to troubleshoot a problem, or simply to make sure that the
software being used is up to date. It is useful to have this information when
reporting a problem to your dealer / distributor. Occasionally check with your dealer
/ distributor for software updates. Press the S/W Version button to view the current
revisions. Press Enter key to print a copy of the displayed information.






Section 4: Operation Operator Manual


G1900
Genmega 2011 4.23
PRINT ALL SETUP
The Print All Setup report is a complete listing of all the programming details for your
ATM. It includes everything from software versions to message screens and host
setup parameters. This report is extremely important when troubleshooting
problems. It is highly recommended to keep a copy of this on hand for when you
need to contact your service personal. To print the report, press the Print All Setup
button, when the report is finished it will prompt you to press Enter to return to the
Reports Menu.


ERROR SUMMARY

This report is a running total of all
errors that have occurred to your
ATM. It lists the errors by the
number of times they occurred.
Sometimes your machine can go
out of service and no error code is
displayed (usually with
communications problems). If this
happens, check the error
summary, as the code will be
displayed here. You can print
these errors To the left is a
sample of an error summary
report.


Press Clear to clear the report and start over. This can be useful if you have a
machine were multiple errors are occurring. If you clear the error codes and then
attempt a transaction, if that transaction fails, the error summary will only show
those errors that occurred during that last transaction. You can also print the error
summary list by pressing the Print button.

STATISTICS
This report keeps running averages
of transaction information,
including:

Withdrawal Transactions per
day
Non-Cash withdrawals per day
(if enabled)
Balance Transactions per day
Transfer Transactions per day
Notes Dispensed per day
Surcharge amount collected per
day



Section 5: Diagnostics Operator Manual


G1900
Genmega 2011 5.1
DIAGNOSTICS

5.1 DIAGNOSTICS MENU

The ATM features built-in diagnostics features to assist you in troubleshooting any
problems that may develop. Below is the main diagnostics menu.




CASH DISPENSER
This will test the ability of the cash dispenser to pull a note from one or both
cassettes (based on how the CDU is programmed) and send it to the reject bin. You
can choose from the first cassette, second cassette or both cassettes at once.

NOTE: You must have bills entered into Settlement before running this test.

PRINTER
This test will print a test receipt. If the test is successful you should receive a receipt
with three sets of sample characters for each time the test is run.


MODEM
The modem test will allow you to enter a phone number into the machine and test
dial. To run the test, press the Modem button and then press Test Dial. Using the
main keypad, enter a phone number to be dialed (for example your cell phone
number) and then press <Enter>. The modem should dial out to the number you
entered. To end the call press Modem Hang up. In most cases a failure during the
modem test will relate more to phone line problems rather than the modem circuit
itself.

Section 5: Diagnostics Operator Manual


G1900
Genmega 2011 5.2

KEYPAD
This tests the keypads of the ATM. Press the Key Matrix button and a map of all
keys will display on the screen. Press the different keys on each keypad (main and
LCD) and the appropriate key will blink on the screen. Pressing the <Cancel> key on
the main keypad will stop this test and return to the diagnostics menu.

CARD READER
This will test the three tracks of the card scanner to ensure they are reading
properly. Press the Card Scan Button, you will see a screen displaying the three ISO
tracks. Swipe your ATM card (or any card with a magnetic stripe) and the
information from that card will appear on the appropriate track. During normal
operation of the ATM only ISO Track 2 is read, however during the card swipe test all
three tracks are read at once.

AGING
The aging test is used at the factory to test machines prior to shipping and for
quality control. Selecting this test will cause the machine to perform all self tests for
an unlimited amount of time.

You can select the options in the Aging Menu for which tests to perform what interval
/ number of times you want the tests to run.





Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.1
CUSTOMER TRANSACTIONS

6.1 OPENING PROCEDURES

This section explains how to place your ATM in service.

Step 1
Open the front panel and turn the power on. (see page 4.1)

Step 2
If there is no receipt paper, load the receipt paper. (see page 4.12)

Step 3
Open the security door and replenish the cash cassette. (see page 4.9)

Step 4
Go into the OPERATOR FUNCTION mode and input the number of bills in the cash
cassette. (See page 4.14)

Step 5
Exit the OPERATOR FUNCTION MODE.

Step 6
After connecting to the processor, the terminal will be ready for service.

Step 7
If the machine is not ready for service, please check the following:
1. Determine if the phone line is properly connected;
2. Determine if all communication parameters are correct;
3. If, after doing the above steps, the ATM is still not in service, contact your
service personnel.



Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.2
6.2 WITHDRAWAL TRANSACTION

Step 1


Insert the card.


Step 2


Enter the pin number and press the ENTER
key.


Step 3


Press the WITHDRAWAL screen key.


Step 4


If a SURCHARGE option is enabled, the
SURCHARGE screen will be displayed.
Select YES to continue, or NO to cancel.

Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.3

Step 5


If YES is selected, the following screen will
be displayed. Select the desired option.


Step 6


Select the desired amount to be withdrawn.
If the desired amount is not displayed, select
the OTHER screen key.


Step 7


After the desired amount is entered, the ATM
dials the processor and requests approval for
the transaction. When authorization is
received from the processor, the cash will be
dispensed.


Step 8


After dispensing cash, a receipt will be
printed.








Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.4
6.3 BALANCE INQUIRY TRANSACTION

Step 1


Insert the card.


Step 2


Enter the pin number and press the ENTER
key.


Step 3


Press the BALANCE screen key.


Step 4


The following screen will be displayed. Select
the desired option.
Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.5

Step 5


The ATM dials the processor and requests
approval for the transaction.


Step 6


When authorization is received from the
processor, the following screen will be
displayed and the receipt will be printed.


Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.6
6.4 TRANSFER TRANSACTION

Step 1


Insert the card.


Step 2


Enter the pin number and press the ENTER
key.


Step 3


Press the TRANSFER screen key.


Step 4


The following screen will be displayed. Select
the desired account to be transferred FROM.

Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.7

Step 5


Select the target account to be transferred
TO.


Step 6


Enter the desired amount to be transferred
and press the ENTER key.


Step 7


The ATM dials the processor and requests
approval for the transaction.


Step 8


When the authorization is received from the
processor, the following screen will be
displayed and the receipt will be printed.


Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.8
6.5 CLOSING PROCEDURE

This section explains the closing procedure for the ATM.

Step 1
Perform the DAY TOTAL and CASSETTE TOTAL functions in the OPERATOR
FUNCTION MODE.

Step 2
Open the security door. Remove the cash from the Cash Cassette and Cash Reject
bin.

Step 3
Print the Journal.

Step 4
If the result of the DAY TOTAL and CASSETTE TOTAL does not match the amount
counted in the Cash Cassette, refer to the Journal for verification.

Step 5
Turn the power off and close the security door.


Section 6: Customer Transactions Operator Manual


G1900
Genmega 2011 6.9
6.6 ERROR RECOVERY

If an error occurs the following screen will be displayed.

Step 1


To access the Operator Function menu, press
the following keys in order <Cancel>, then
<Clear>, then <Enter> then 1, then 2, then
3.



Step 2


Verify the Error that has occurred through the
ERROR CODE of the REPORT MENU in the
OPERATOR FUNCTION, menu and perform
the corrective action, then press the DEVICE
INITIALIZE screen key.

If the Error is not corrected after resetting,
contact your service personnel.



Appendix A: Error Codes Operator Manual


G1900
Genmega 2011 A.1
APPENDIX A: Error Codes

ERROR
CODES
ERROR DESCRIPTION CORRECTIVE ACTION
20001 Unable to load a cassette. Remove and replace cassette Check the micro-switch
located on the inside left wall of the dispenser.
20002 Low Cash. Replenish the cash If using less than 75 bills, disable the
Low Cash Warning in the Transaction Setup Menu.
20003 Reject Bin full. Empty the Reject Bin If the bin is empty, do a Day Total
and then a Cassette Total If that doesnt help, check AP,
BIOS and CDU ROM versions.
20004 Vault Door is open. Check vault door switch (located upper left corner)
check that black and white, 2-wire connector is properly
connected at rear of main board. Bend switch forward to
aid closing problems.
20010 Receipt paper jam. Remove jammed paper Release receipt paper drawer by
pressing the tab with the green sticker located at the front
of the printer. Remove printer to locate difficult jams.
20012 Receipt feed lever open. Close the feed lever on the printer.
20013 Receipt paper empty. Replenish the paper roll.
20014 Thermal printer is
overheated.
Contact manufacturer.
2xx15 Cash Dispenser detects
bills prior to dispensing.
Remove any jammed bills from the dispenser.
90001 Card Swipe Error. This does not mean the card reader is bad. Just records
unsuccessful attempts at swiping cards.
Axxx1 Receipt Printer feed lever
open during operation.
Close the feed lever on the printer.
Axxx2 Thermal printer is
overheated during
operation.
If problem is consistent then print head assembly may be
defective.
Axxx3 Receipt paper jam. Remove jammed paper Release receipt paper drawer by
pressing the tab with the green sticker located at the front
of the printer.
Axxx4 Receipt paper is empty. Replenish the paper roll.
Axxx5 Receipt paper is jamming
during loading.
Remove any jammed paper and then reload.
Axxx8 Receipt Printer cutter
error.
If consistent, printer will require repair/replacement.
ADNxx Printer connection error. Check cables between Printer and Mainboard. Remove
cables (even though they may be attached) and
reconnect.
CANCE Surcharge Cancel Customer has canceled the transaction at surcharge.
C0011 Exit sensor is not cleared Check sensor, verify that the cabling plugged into the
sensor boards is secure.
C0012 Reject gate timing sensor
not cleared.
Check dispenser for jammed bills and reinitialize the
machine.
C0013 Both reject gate and exit
sensor not cleared
Check dispenser for any notes or obstructions.
C0017 Undefined
C0021 Double detect sensor is
not cleared.
Check dispenser for jammed bills and reinitialize the
machine.
C0022 1
st
cassette inlet sensor
not cleared.
Check dispenser and cassette for jammed bills.
C0023 Cassette exit sensor (L+R)
not cleared.
Check dispenser for jammed bills and reinitialize the
machine.
Appendix A: Error Codes Operator Manual


G1900
Genmega 2011 A.2
ERROR
CODES
ERROR DESCRIPTION CORRECTIVE ACTION
C0028 Count sensors not cleared Check dispenser for jammed bills and reinitialize the
machine.
C0030 Main Motor encoder is not
synchronized
Turn dispenser over by hand, and then reinitialize. May
require repair.
C0031 Forward motor encoder
not synchronized.
Turn dispenser over by hand, and then reinitialize. May
require repair.
C0032 1
st
cassette inlet sensor
not cleared
Check for notes where the cassette engages the
dispenser.
C0033 Undefined
C0036 Exit sensor blocked while
initializing
Clear any notes which may be blocking the exit sensor.
C0037 Invalid response (or no
response) from double
detect sensor
Verify the connection to the double detect module.
C0039 Solenoid not responding Verify the function of the gate solenoid.
C003A Too many notes requested
during a test dispense
Test dispense failed, re-run the test and check notes.
C0041 Failed (5 times) to
dispense a note after a
successful dispense
Check why notes are rejecting following at least one
successful dispense (in the same transaction).
C0042 Undefined
C0043 10 Notes rejected in a row
(single transaction)
Check the notes in the cassette. Check reject analysis for
source of rejected notes (long note, double-detect, etc)
C0044 5 notes consecutively
rejected
Check reject analysis for cause of rejected notes.
C0045 Note count sensor
reporting mismatch
Verify count of notes in the cassette against the
settlement.
C0046 Undefined
C0047 1
st
cassette failed to
dispense a note
Most common reason is cassette is empty. Verify that
there are notes in cassette 1. Check the quality of the
notes and condition of the pick rollers.
C0049 Dispense request of 0
notes
Check setup of CDU in Operator Menu, dispenser may
need reprogramming.
C004A First cassette exit sensor
(#6, #7) not clear
Clear the note path of any notes or obstructions.
C004D 1
st
cassette not inserted Check cassette and verify that its inserted properly.
C004E 2
nd
cassette not inserted Check cassette and verify that its inserted properly.
C0050 AP does not receive
response after dispense
request
AP did not validate dispense command. This is an AP
software fault, not CDU.
C0051 Exceeded maximum
number of notes dispensed
(150) in a single trans.
Check reject analysis, and verify test dispense.
C0052 1
st
cassette inlet sensor
not cleared
Check for notes where the cassette engages the
dispenser.
C0053 Abnormal amount of
double-detect failures
during dispense
Check condition of double-detect module. Check quality of
notes and pick rollers.
C0054 Undefined
C0055 Long note detected at exit
sensor during dispense
Clear any jammed notes or obstructions from the exit
sensor.
C0056 Short note detected at exit
sensor during dispense
Clear any jammed notes or obstructions from the exit
sensor; mismatch of rejected notes.

Appendix A: Error Codes Operator Manual


G1900
Genmega 2011 A.3
ERROR
CODES
ERROR DESCRIPTION CORRECTIVE ACTION
C005A Undefined
C005B 2
nd
cassette fails to pick up
notes
Same as C0047, the second cassette is likely empty.
C0060 3
rd
cassette inlet sensor
not cleared
Check for notes where the 3
rd
cassette engages the
dispenser.
C0062 3
rd
cassette inlet sensor
not cleared
Check for notes where the 3
rd
cassette engages the
dispenser.
C006A Note jam at 2
nd
cassette
exit
Check rollers and sensors where notes would leave the 2
nd

cassette.
C0070 4
th
cassette inlet sensor
not cleared
Check for notes where the 4
th
cassette engages the
dispenser.
C0072 4
th
cassette inlet sensor
not cleared
Check for notes where the 4
th
cassette engages the
dispenser.
C007A Note jam at 4
th
cassette
exit
Check rollers and sensors where notes would leave the 4
th

cassette.
C007C 4
th
cassette fails to pick up
notes
Same as C0047/C005B, verify that there are notes in the
4
th
cassette.
C007D 4
th
cassette not inserted Check cassette and verify that its inserted properly.
C0080 2
nd
cassette inlet sensor
not cleared
Check for notes where the 2
nd
cassette engages the
dispenser.
C0081 Double detect sensor not
cleared while dispensing
Check double-detect senor for note or obstruction.
C0082 Note leaving cassette exit
sensor did not reach DD
A note seen at cassette exit sensors did not reach the
double detect module. Check for jammed notes.
C0083 Reject gate timing sensor
#2 not cleared during
dispense.
Clear the note path before the reject gate.
C0084 Reject gate timing sensor
#3 not cleared during
dispense.
Clear the note path before the reject gate.
C0085 Note leaving DD sensor did
not reach gate sensor
Check the note path for jammed or diverted notes. Check
sensors from #5 to #2/#3.
C0086 Note leaving gate sensor
did not reach count sensor
Check for jammed notes between #2/#3 sensors and
#0/#1 sensors.
C0090 Sensor check error Left measuring sensor A (#6/#7)
C0091 Sensor check error Right measuring sensor B (#6/#7)
C0092 Sensor check error Left gate timing sensor A (#2/#3)
C0093 Sensor check error Right gate timing sensor B (#2/#3)
C0094 Sensor check error Exit sensor (#4)
C0095 Sensor check error Double Detect (#5)
C0096 Sensor check error Left count sensor A (#0/#1)
C0097 Sensor check error Right count sensor B (#0/#1)
C009A Note jam at 3
rd
cassette
exit
Check rollers and sensors where notes would leave the 3
rd

cassette.
C009D 3
rd
cassette not inserted Check cassette and verify that its inserted properly.
C009F 3
rd
cassette fails to pick up
notes
Similar to C0047, C005B verify that there are notes in the
cassette.
D0001 Modem initializing failure. This error is reported from the host. Check that
programming is correct for this processor.
D0002 Reversal transaction failed. Check transaction with the processor. Verify CDU
functionality with diagnostics. Verify phone connection.
D0012 Invalid transaction. Network denial code.
D0013 Invalid Amount. Network denial code.
D0014 Invalid Card Number. Network denial code.
D0020 Surcharge screen should
have been displayed.
Network denial code.
Appendix A: Error Codes Operator Manual


G1900
Genmega 2011 A.4
ERROR
CODES
ERROR DESCRIPTION CORRECTIVE ACTION
D0024 Exceeds issuer withdrawal
limit.
Network denial code.
D0039 No credit account. Network denial code.
D0051 Insufficient funds. Network denial code.
D0052 No checking account. Network denial code.
D0053 No savings account. Network denial code.
D0054 Expired Card. Network denial code.
D0055 Invalid PIN. Network denial code.
D0057 Transaction not permitted
card
Network denial code.
D0058 Transaction not permitted
Terminal
Network denial code.
D0061 Exceed withdrawal limit. Network denial code.
D0075 Number of PIN tries
exceeded.
Network denial code.
D0078 No Account. Network denial code.
D0080 Invalid Date. Network denial code.
D0083 Cannot verify PIN. Network denial code.
D0086 Cannot verify PIN. Network denial code.
D0091 Bank unavailable. Network denial code.
D0092 System unavailable. Network denial code.
D0093 Transaction serial number
mismatch.
Contact host processor.
D0094 Record format mismatch. Contact host processor.
D0095 Routing ID mismatch. Verify Routing ID number Contact host processor.
D0096 Terminal ID mismatch. Verify Terminal ID number Contact host processor.
D0097 Response type mismatch
(reversal).
Contact host processor.
D0098 Response type mismatch
(day-close).
Contact host processor.
D0099 Response type mismatch
(Configuration).
Contact host processor.
D009A Response type mismatch
(Withdrawal, Balance,
Transfer).
Contact host processor.
D009B STX omitted. Contact host processor.
D009C ETX omitted. Contact host processor.
D009D FS omitted (after response
code).
Verify that version of ATM Software matches host
processor. Contact host processor.
D009E FS omitted (after retrieval
reference number).
Verify that version of ATM Software matches host
processor. Contact host processor.
D009F FS omitted (after system
trace audit number).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A0 FS omitted (after account
balance).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A1 FS omitted (after available
balance).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A2 FS omitted (after available
balance).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A3 FS omitted (after
authorization response
text).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A4 ETX is in wrong place. Verify that version of ATM Software matches host
processor. Contact host processor.

Appendix A: Error Codes Operator Manual


G1900
Genmega 2011 A.5
ERROR
CODES
ERROR DESCRIPTION CORRECTIVE ACTION
D00A5 FS omitted (after total
cash dispense amount in
day close).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A6 FS omitted (after total non
cash dispense amount in
day close).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A7 FS omitted (after
surcharge amount in day
close message).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A8 FS omitted (after
surcharge in configuration
message).
Verify that version of ATM Software matches host
processor. Contact host processor.
D00A9 ETX omitted (from
configuration message).
Contact host processor.
D0300 Modem is not responding. Verify modem function.
D1000 No Connection. Verify modem function.
D1100 ENQ not received from
host.
Contact host processor.
D1200 Transmission error. Verify modem function.
D1300 NAK sent 3 times to host. Verify host phone number See D170x.
D1500 Modem connection time
out host not responding.
Verify host phone number verify modem speed See
D170x. If consistent, it could be a defective modem.
D170x Modem cannot support
connection excessive line
noise (usually D1704/06)
Phone line connected to ATM will not support Data-
communication. In line filter may fix this. Excessive EMI
emissions from outside source (neon sign, freezer).
D1800 No dial tone. Verify that incoming phone line is plugged into line
rather than Phone on mainbaord. Phone line is in use or
is being shared with another phone device (FAX, POS,
phone)
D1900 No answer. Verify host phone number See D170x
D2000 Phone line busy. Verify host phone number call line with handset and
check for busy signal See D170x
D2100 Modem initializing error. Check modem.
D2200 EOT not received from
host.
Contact host processor.
D25xx Network Connection See page 3.33 of Operator Manual
E000x RMS port failure, response
time out, modem failure,
no dial tone.
Verify RMS settings (Host Setup) See D170x
F0001 Current Number of bill is
0.
Load notes into the cash cassette use Add Cassette
function in Settlement.
F0002 No Surcharge Owner set. Set Surcharge owner (Customer Setup)
F0003 No Surcharge Amount. Set Surcharge amount (Customer Setup)
F0004 No refresh time set when
advertisement is enabled.
Set refresh timer (Customer Setup)
F0005 No Advertisement text
when advertisement is
enabled.
Set Advertisement text (Customer Setup)
F0006 Dispense limit set error
(less than 25 notes)
Set Dispense limit (Transaction Setup)
F0007 Denomination Set error. Valid Denomination are $10, $20, $50, $100
(Transaction Setup)
F0008 Fast Cash Set error
(exceeded dispense limit).
Check the Fast Cash amount. (Transaction Setup)
F0009 Master Key index is
invalid.
Check Master Key index verify checksum (Host Setup)
Appendix A: Error Codes Operator Manual


G1900
Genmega 2011 A.6
ERROR
CODES
ERROR DESCRIPTION CORRECTIVE ACTION
F000A Master Key is empty. Check Master Key checksum reinject key (Host Setup)
F000B Host Telephone Number is
not set.
Set Host Telephone Number (Host Setup)
F000C Error Retry timer is not
set.
Set Error retry time (Host Setup)
F000D RMS Password is not set
when RMS is enabled.
Set RMS Password (Host Setup)
F000E RMS phone number is not
set when RMS send is
enabled.
Set RMS Phone number (Host Setup)
F000F Terminal ID is not set. Set Terminal ID number (Host Setup)
F0010 Routing ID is not set. Set Routing ID number (Host Setup)
F0011 Master Key Serial number
is not set
Set Master Key serial number (Host Setup)
F0013/
14
NVRAM Failure Fatal error, defective memory chip. Replace Mainboard.
F0015 Serial Number not Set Set Serial number in Operator Menu
F0016 Master Password left at
default
ATM will not go into service with the default master
password. The master password must be changed from
default.


Appendix B: Keypad Addendum Operator Manual


G1900
Genmega 2011 B.1
APPENDIX B: CLEARING NVRAM

To clear NVRAM on the Genmega G1900, begin by entering the Operator Function
Menu using the Master Password. Next enter the Customer Setup Menu.

Press the lowest button on the right side of the LCD panel. This will give you access
to the CLEAR NVRAM Menu.



*** WARNING ***

Once in the CLEAR NVRAM Menu, there is no extra authorization before data will be
wiped out permanently. DO NOT press any key within this menu unless you are
absolutely sure you want to permanently delete this data!

CLEAR JOURNAL
Selecting this will delete all journal data permanently

CLEAR NVRAM
This will delete all programmed parameters and return everything (including
passwords) to the default settings. This does NOT include the master keys which are
stored in the EPP.

CLEAR JOURNAL AND NVRAM
This option performs both of the options listed above. Both the programmed
parameters and journal are permanently deleted and all settings are returned to
default.

USE CAUTION WITH THESE FEATURES DATA LOST CANNOT BE RECOVERED

Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.1
APPENDIX C: Master Key Installation




Master Key Installation

Master keys are entered only through an approved EPP (Encrypting Pin Pad) device and
are stored in the keypad. These keys, along with another key downloaded from your
processor are used to encrypt the PIN numbers for customer transactions.

Two Passwords (Secure Mode Passwords) are required in order to enter Key Mode and
change any options.

NOTE: You will NOT be able to enter keys or change key mode until the Secure Mode
Passwords have been changed from default. After changing both passwords, you must
back out of the operator menu and reinitialize the ATM.

Please follow the procedures below to begin this process.



Installation Procedure:

To access the Key Management menu from Host Setup, youll need to enter the Secure
Mode Password (parts 1 and 2). See page 3.6 for Secure Mode instructions.


Default Secure Mode password is:

Part #1 = 000000 / Part #2 = 000000


Access the Key Mode selections by entering
the operator function menu

[ENTER]+[CLEAR]+[CANCEL] + 1 + 2 + 3

Enter Master Password and choose Host
Setup

Note: Master Password is required to access
Key Management Menu.

NOTE: You must change the Secure Mode Password from default before any changes can
be made to Key Management, or enter any keys. Change the default passwords for Part
#1 and Part #2 and then completely exit the Operator Menu (cancel out and let machine
initialize) Once you go back in and use the new Secure Mode Passwords, youll be able
to make changes or enter keys.

Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.2
1) Select Key Mode

The table below describes the format for each key mode.

DES 2 - 16 digit master keys entered as Part A and Part B.
Dual Master
Key
2 - 16 digit master keys entered as Part A and Part B (a
common key is entered, and then a working key is
downloaded from the host).
Unique Key,
DES
2 - 16 digit master keys entered as Part A and Part B -
with 10 digit unique serial number entered prior to each
part.
TDES
2 32 digit master keys entered in 16 digit pieces, Part A
(left and right) and Part B (left and right)
Unique Key,
TDES
2 32 digit master keys entered in 16 digit pieces, Part A
(left and right) and Part B (left and right) - 10 digit unique
serial number entered prior to each part.
MAC
2 -16 digit master keys entered as Part A and Part B, with
2 additional 16 digit numbers entered as MAC Part A and
Part B
Unique Key,
MAC
2 -16 digit master keys entered as Part A and Part B, with
2 additional 16 digit numbers entered as MAC Part A and
Part B - 10 digit unique serial number entered prior to
each part of the master key only.
TDES, MAC
2 32 digit master keys entered in 16 digit pieces, Part A
(left and right) and Part B (left and right), with 2
additional 16 digit numbers entered as MAC Part A and
Part B


Under most circumstances, youll be using TDES as Key Mode.

Unique Key modes use a unique 10 digit serial number that is entered before each half of
the master key to allow the processor to bind the key to the terminal ID automatically.
In cases where the processor provides a serial number that is less than 10 digits, zeros
must be added at the beginning of the number to equal 10 digits.





Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.3


2) Entering A Master Key

Master Key security requires that no one person has access to all parts of the key. To
ensure this, the processor will provide keys in separate sealed envelopes (sometimes
referred to as key components). Each envelope contains either one or two 16 digit
keys and in the case of unique key, a serial number. The diagram below shows a
sample Unique Key, TDES master key.





Begin by choosing Edit Master Key from the
menu

Depending on Key Mode, the menu prompts
for Part A and Part B.

The Edit Master Key interface is designed so that Parts A and B can be entered at
completely different times and in either order (Part A first, or Part B first). If a technician
is dispatched to enter a key part, choose Check Key from the Key Management menu to
determine which part of the key has already been entered.

Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.4

Partially entered keys will appear in the
index as #### or **** which denotes that
either part A or part B has been successfully
entered. (A = #, B = *)

This would tell the second technician that
they need to enter their key as Part B on
index 12.

Part1 = Part A / Part2 = Part B






Once you have selected Part A or B, youll
be prompted to enter a Key Index.

This index points to the location where the
key will be stored. There are 16 possible
memory locations (0-15) available. Unique
master keys must be stored at location #12,
and MAC keys at location #15.


The interface will default the values for Unique and MAC keys regardless of what you
enter. It is very important to remember that both parts of a key must be entered on the
same index. If you enter Part A on index #2 and Part B on index #3 the key will not be
complete. Use the Check Key function (shown above) to determine where your keys
parts have been entered.


If entering a Unique key, next youll be
prompted to enter the key serial number.

This 10 digit number is found on the
paperwork containing your master key(s).
If the number the processor has provided is
less than 10 digits, youll need to add zeros
to the beginning of the number to equal 10
digits.



In the example shown at left, the serial
number is 123456. This 6 digit number
would be changed to 0000123456 to
create 10 digits.

Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.5

The next step is to enter the master key
itself. If you are using TDES, youll need to
enter the left portion first.

After entering the key, youll be prompted to
enter it a second time for verification.


The 16 digit alpha-numeric key is
entered using the pin-pad only.

Letters are entered by using the arrow
and function keys. Use the pin-pad
layout below.





1 2 3 F

4 5 6 E

7 8 9 D

A 0 B C


EPP (Encrypted Pin Pad) Master Key Alpha-Numeric Key Layout




Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.6
At this point the left (or first 16 digit) portion of the master key has been entered
successfully.







If you are entering a 32 bit key (TDES), the
second or Right half of the key is entered
next.

This option will only appear when in TDES
mode.


After entering the right portion of the
key successfully youll be prompted with
a check digit as shown below. Verify the
check digit with the information provided
by the processor.
















Check digits appear after entering both
the right and left portion of each part of
the key.









Compare the check digit against the
number located at the top of the key
component. This represents a check
digit for the combined keys. There is not
a check digit shown for left and right
portions individually.
Appendix C: TDES Key Installation Operator Manual



G1900
Genmega 2011 C.7

After successfully entering both the left and
right portions of Part A, youll be returned to
the Edit Master Key menu.

At this point you can proceed with Part B, or
if Part B is to be entered at a later time you
can exit the menu and power off the
machine until both halves of the key are
entered.

Part B is entered with the same procedure given for Part A. Enter the left and right (for
TDES) portions of the keys and verify the check digits against what has been provided by
the processor.



3) Verifying Master Key





Once both Part A and Part B have been
entered successfully, the key management
menu will display a check digit for the key
index where the master key was entered. If
no check digit is entered, use the check key
screen to determine where the key parts
were entered, then re-enter the keys as
necessary.






At this point, the master key is successfully entered. If all other parameters have been
entered properly, power off the ATM and power on to connect to host and initialize the
keys.




Appendix D: Graphics Installation Operator Manual



G1900
Genmega 2011 D.1
APPENDIX D: Custom Screen Graphics


Advertisement screens can be loaded to the Genmega G1900 machine
either using a SDRAM card (at the ATM) or by using remote monitoring
software (to load remotely). Please see below for basic file format
specifications and instructions for use with a SDRAM card.





You can have up to 8 center graphic files and must be named as followed:

center1.bmp, center2.bmp, and so on up to center8.bmp

DO NOT use more than 256 colors when creating the graphic images.
The G1900 was designed to use graphics of that format for
efficiency and best performance*




WELCOME
C Ce en nt te er r A Ad dv ve er rt ti is se em me en nt t G Gr ra ap ph hi ic c
Width : 422 Pixels
Height : 309 Pixels
File Name
center1.bmp
center2.bmp
..
center8.bmp (default on)
File Size : 204,888 BYTES
bmp File Format
: 8bit (256 colors) BMP
: No Compression
Appendix D: Graphics Installation Operator Manual



G1900
Genmega 2011 D.2
Loading Graphics using SD (Secure Digital) card

SD card should be less than 2GB capacity and formatted as FAT
or FAT16 file system

SD card reader is required to load files from your PC


To prepare the SD card for uploading graphics.
1. Remove all the data from the SD card.
2. Create a blank file called update.acu and save it on the card.

To create this file:
a. Open up a blank notepad document.
[Start All Programs Accessories Notepad]
b. Save the blank document as update.txt in the SD card.



c. Once its saved rename the file to update.acu.

once renamed, the icon changes

After the update.acu file has been created, copy it to the root folder of
the SD card.

Appendix D: Graphics Installation Operator Manual



G1900
Genmega 2011 D.3
3. Open the SD card in My Computer, and create a folder called
Common.
4. Open the Common folder, and create a sub-folder called img4SCR.
5. Inside the img4SCR folder is where you want to copy all your graphic
files.
- The graphic files must follow the naming convention that we describe
on page 1. (ie: center1.bmp, center2.bmp or top1.bmp, top2.bmp).

6. Once your graphic files are copied, insert the SD card into the SD card
slot on the mainboard located behind the LCD.
7. Power off, then power on the 1900 with the power supply switch.
8. When the ATM is fully initialized then remove the SD card.

Enabling the Center Graphics:
1. Go into the Operator Menu.
2. Then to Customer Setup > Graphics > Advertise EN/Disable and go
through each advertisement you want to show up and turn it ON.

Enabling the Banners Graphics:
1. Go into the Operator Menu.
2. Then to Customer Setup > Graphics > Banner EN/Disable and go
through each banner you want to show up and turn it ON.

Windows XP users:

Before creating the file in step #2, you may need to change your file options.
Open a folder and click on Tools, select Folder Options

Make sure Folder Options match
those shown here. Specifically
the Hide extensions for known
file types option which needs
to be unchecked.

If these options are not set
properly, the update.acu file
may not function, causing the
graphics to not load.