Balluff is a worldwide leading company in the field of position detection. Our product lines include electronic sensors, transducers employing various operating principles, identification systems, buscapable sensors as well as electromechanical and inductive multiple and single position switches. Balluff products are found wherever accuracy and reliability are demanded.
Wherever there is a need to automate, sense objects, or report linear and rotary motion to controllers Balluff is always the right partner. Our QM system meets the requirements of DIN EN ISO 9001:2000. Eleven Balluff companies have a certified QM system, two a certified environmental protection system.
By mastering processcapable production and assembly techniques and statistical process control we achieve consistently high product quality. Intensive testing prior to series production ensures reliable function. With more than 50 years of experience in the field of sensors, the Balluff Group is today one of the most capable manufacturers of
standard as well as custom position switches. Innovative technology and applicationspecific customer solutions are the hallmarks of the entire product range. Highly qualified development engineers and experienced designers work closely with the manufacturing side to ensure mature series products that are used successfully in every area of automation even under extreme and aggressive operating conditions.
BTL Micropulse Transducer/BIW Inductive Linear Position Sensors Extremely rugged and reliable
Greater flexibility through full range of sensing principles More efficiency through optimal solutions Increased productivity through well-engineered displacement sensing technology
Displacement sensing the right solution for your application You work efficiently and need optimal solutions? For your displacement sensing Balluff gives you exactly what you need. Various operating principles are available: For distances of 1 to 48000 mm and resolutions from 1 to 100 m. The choice is yours. Simply pick the system that's right for your. And let Balluff help add value to your process. Balluff displacement sensing technology: Rugged and designed for industry, precise and reliable, non-contact and wear-free
www.balluff.com
Micropulse Transducer
Micropulse+: The new standard in industrial hydraulics Save time. Reduce your production costs. The Micropulse+ is up and running in no time. Configure the parameters over a USB interface and profit from the easy setup. Make full use of the high functionality. And use two freely programmable outputs. Status and diagnostic LEDs mean more security. Increased shock and vibration resistance guarantee reliable operation: More efficiency with Micropulse+.
Balluff displacement sensing technology: Rugged and designed for industry, precise and reliable, noncontact and wear-free More added value Save time with fast startup and simple parameter setting Increased reliability with well-engineered technology More efficiency through high functionality
Micropulse Transducer
6 8 12 14 15 16 19
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
BTL7
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
Micropulse Transducer
Pressure rated to 600 bar, high repeatability, non-contacting, rugged The BTL Micropulse transducer is the rugged linear displacement system for use under extreme ambient conditions for measuring ranges between 25 and 7600 mm. The actual sensing element (waveguide) is protected in a high pressure rated stainless steel tube. The system is ideal for use in hydraulic cylinders for position feedback or for level control in aggressive media in the foods and chemical industries.
Series Shock load Vibration Polarity reversal protected Overvoltage protection Dielectric strength Enclosure rating per IEC 60529 Housing material Mounting Pressure resistance with 10.2 mm outer tube Pressure resistance with 8 mm outer tube Connection type EMC tests: RF emission Static electricity (ESD) Electromagnetic fields (RFI) Rapid transients (BURST) Withstand voltage (SURGE) Line-carried noise, induced by high-frequency fields Magnetic fields Standard nominals strokes [mm] for 8 mm rod the max. nominal stroke is 1016 mm
BTL7 Rod 150 g/6 ms per IEC 60068-2-27 20 g, 10...2000 Hz per EN 60068-2-6 yes Transzorb protection diodes 500 V AC (GND to housing) IP 68 for cable style, IP 67 for BKS-S... connector style (when connected) Anodized aluminium/1.4571 stainless tube, 1.3952 stainless investment cast flange Housing B thread M181.5, housing Z 3/4"-16UNF 600 bar when installed in hydraulic cylinder 250 bar when installed in hydraulic cylinder connector or integral cable EN 55011 Group 1, Class A and B EN 61000-4-2 Severity Level 3 EN 61000-4-3 Severity Level 3 EN 61000-4-4 Severity Level 3 EN 61000-4-5 Severity Level 2 EN 61000-4-6 Severity Level 3 EN 61000-4-8 Severity Level 4 0025, 0050, 0075, 0100, 0125, 0150, 0175, 0200, 0225, 0250, 0275, 0300, 0325, 0350, 0375, 0400, 0425, 0450, 0475, 0500, 0550, 0600, 0650, 0700, 0750, 0800, 0850, 0900, 0950, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000, 2250, 2500, 2750, 3000, 3250, 3500, 3750, 3850, 4000, 4250, 4500, 4750, 5000, 5250, 5500, 5750, 6000, 6250, 6500, 6750, 7000, 7250, 7500, 7600 or in 5 mm increments (depending on steps) on request
Please order separately: USB communication box page 13 Magnets page 15 Mounting nuts page 15 Connectors starting page 16
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com.
Micropulse Transducer
BTL7 Rod
Magnet
B=S
rd s anda
eries
Thread M4 4/6 deep Thread M18x1.5
Mounting surface
BTL7
Damping zone (non-usable area)
General data
Magnet
Mounting surface
Housing B8 BTL7_ _ _ _ -B8-_ _ _ _ Metric mounting thread M181.5 8 mm tube max. 1016 mm nominal stroke
Thread M18x1.5
Mounting surface
Housing Z8 BTL7_ _ _ _ -Z8-_ _ _ _ 3/4" UNF mounting thread 8 mm tube max. 1016 mm nominal stroke
Mounting surface
Housing A BTL7-_ _ _ _-A-_ _ _ _ Metric mounting thread M181.5 Flange without 0.5/ 25 mm mounting surface
Mounting surface
www.balluff.com
Micropulse Transducer
Features of Micropulse BTL7-A/C/E/G...B Status LEDs for indicating operating status and diagnostics Extended application range with high enclosure rating IP 68 (cable version) Electronics head can be replaced if needed Short housing, saves space Error signal, no magnet in range Flexible measuring range Ordering code The start and end point of the active stroke can be set as needed in the application. The points are set using the included calibration device directly on the unit or remotely, see page 12. Output voltage Output current Load current max. ripple Load resistance System resolution Hysteresis Repeatability Sampling rate length-dependent max. non-linearity BTL7- A110-M_ _ _ _-... 0...10 V and 10...0 V max. 5 mA 0.5 Vpp 0.33 mV 5 m System resolution/min. 2 m max. 4 kHz 50 m to 500 mm nominal stroke 0.01 % FS > 500... 5500 mm nominal stroke 0.02 % FS > 5500 mm nominal stroke 30 ppm/K 20...28 V DC 150 mA yes yes 500 V AC (ground to housing) 40...+85 C
Temperature coefficient Supply voltage Current draw at 24 V DC Polarity reversal protected Overvoltage protection Dielectric constant Operating temperature Connect shield to housing
Included: Transducer Calibration device Short user's guide Please order separately: USB communication box page 13 Magnets page 15 Mounting nuts page 15 Connectors starting page 16
Please enter code for output signal, nominal stroke, housing style and connection type in the order code! Preferred models Interfaces A110 and E100 BTL7-A110-M_ _ _ _-B-S32, BTL7-E100-M_ _ _ _-B-S32 highlighted in blue are available from stock.
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com.
Micropulse Transducer
BTL7
BTL7-C1_0-M_ _ _ _-...
4...20 mA or 20...4 mA max. 5 mA 0.5 Vpp 0.33 mV 500 Ohms 0.66 A 5 m System resolution/min. 2 m max. 4 kHz 50 m to 500 mm nominal stroke 0.01 % FS > 500... 5500 mm nominal stroke 0.02 % FS > 5500 mm nominal stroke 30 ppm/K 20...28 V DC 150 mA yes yes 500 V AC (ground to housing) 40...+85 C
Output signal A G E C 1
Output signal for A and G rising and falling for C and E rising for C and E falling
Standard nominal stroke [mm] 0025, 0050, 0075, 0100, 0125, 0150, 0175, 0200, 0225, 0250, 0275, 0300, 0325, 0350, 0375, 0400, 0425, 0450, 0475, 0500, 0550, 0600, 0650, 0700, 0750, 0800, 0850, 0900, 0950, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000, 2250, 2500, 2750, 3000, 3250, 3500, 3750, 3850, 4000, 4250, 4500, 4750, 5000, 5250, 5500, 5750, 6000, 6250, 6500, 6750, 7000, 7250, 7500, 7600 or in 5mm increments (depending on steps) on request
Connection type S32 S115 KA02 KA05 KA10 KA15 Connector Connector PUR cable PUR cable PUR cable PUR cable
2m 5m 10 m 15 m
www.balluff.com
Micropulse Transducer
Position and Velocity Two outputs can be assigned as desired for position value and velocity signal using the USB interface. Mode examples:
Features of Micropulse+ USB-Configurable BTL7-A/E501 Simple configuration and setting of the start and end point over the USB interface, fast startup "Easy Setup" for manual adjustment Configurable dual output functions, position and velocity Increased operating security with status LEDs for indicating the operating status and diagnostic information Extended application range with high enclosure rating IP 68 (cable version) Electronics head can be replaced if needed Short housing Error signals, magnet ring out of range
Double magnet
Ordering code Factory settings output signal Output signal adjustable using USB Configurable Load current max. ripple Load resistance System resolution Current draw at 24 V DC Hysteresis Repeatability Sampling rate length-dependent max. non-linearity
Differential
Velocity
Velocity output
10
Temperature coefficient Operating voltage Polarity reversal protected Overvoltage protection Dielectric strength Operating temperature Connect shield to housing Please enter code for output signal, nominal stroke, housing style and connection type in the order code! Preferred models Interfaces A501 and E501 BTL7-A501-M_ _ _ _-B-S32, BTL7-E501-M_ _ _ _-B-S32 highlighted in blue are available from stock. Included: Transducer Calibration device Short user's guide Please order separately: USB communication box page 13 Magnets page 15 Mounting nuts page 15 Connectors starting page 16
Micropulse Transducer
BTL7 Rod analog E analog
BTL7
Factory settings Factory settings
BTL7-A501-M_ _ _ _-... 0...10 V and 10...0 V 10...10 V and 10...-10 V max. 5 mA 0.5 Vpp 0.33 mV 150 mA
BTL7-E501-M_ _ _ _-... 4...20 mA and 20...4 mA 0...20 mA and 20...0 mA 500 Ohms 0.66 A 180 mA
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
5 m System resolution/min. 2 m max. 4 kHz 50 m to 500 mm nominal stroke 0.01 % FS > 500... 5500 mm nominal stroke 0.02 % FS > 5500 mm nominal stroke 30 ppm/K 10...30 V DC yes yes 500 V AC (ground to housing) 40...+100 C
Standard nominal stroke [mm] 0025, 0050, 0075, 0100, 0125, 0150, 0175, 0200, 0225, 0250, 0275, 0300, 0325, 0350, 0375, 0400, 0425, 0450, 0475, 0500, 0550, 0600, 0650, 0700, 0750, 0800, 0850, 0900, 0950, 1000, 1100, 1200, 1300, 1400, 1500, 1600, 1700, 1800, 1900, 2000, 2250, 2500, 2750, 3000, 3250, 3500, 3750, 3850, 4000, 4250, 4500, 4750, 5000, 5250, 5500, 5750, 6000, 6250, 6500, 6750, 7000, 7250, 7500, 7600 or in 5mm increments (depending on steps) on request
Connection type S 32 S115 KA02 KA05 KA10 KA15 Connector Connector PUR cable 2 m PUR cable 5 m PUR cable 10 m PUR cable 15 m
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com.
www.balluff.com
11
Micropulse Transducer
Setting options for the start and end point BTL7 Standard 2. Remote setup aid Teach-in You wish to replace the factory default start and end point with a new start and end point. Bring the magnet first to the new start and then to the new end position, and their associated value is stored by pressing a button. Adjustment Here you can adjust a new start and/or end value. This is recommended when the magnet cannot be brought to the start or end point. Alternately move the magnet to the new start and end position and adjust the respective displayed value by briefly pressing the buttons or holding them down until the desired values are reached. Online setting This programming function allows you to set the start and end point on-the-fly, e.g. in a closed loop system. No Error value is output during the setup procedure. The adjustable range is limited to 25 %.
Save new null value 2. Move magnet ring to the new end position.
1. Calibration device Teach-in Adjustment Online setting Easy-Setup 2. Remote setting 3. USB-Configurate 1. Calibration device 100 % start and end point adjustment The start and end point of the analog signal can be located at the desired position with the push of a button. Depending on the application, either teach-in or manual adjustment is used, selected by pressing a key combination. Two-color LED indicators assist the procedure. "Easy-Setup" For BTL7-A/E501, Micropulse+only. Simple programming mode for adjusting the start and end point of the transducer to the current application in just a few steps. The magnet is brought to the new position. Confirm by pressing a button. The "Adjust" function allows the new value to be fine-tuned for a stationary magnet ring. No Error value is output during the setup procedure.
Setting start and end point using the calibration device BTL7-A/E501
Remote setting of the start and end point using programming inputs
L b, Pin 8
L a, Pin 4 Button 1 24 V
Button 2
If the transducer is located in an inaccessible place or a hazardous area, the start and end point setting can be made remotely. Teach-in, adjustment and online setting are identical to programming with the calibration device. Button 1 blue corresponds to programming input La, Button 2 gray to input Lb.
Buttons inactive
Teach-in
Adjustment
Start point
End point
Start point
End point
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com.
12
Micropulse Transducer
3. USB-Configurate Start, end value setting and configuration via USB The Micropulse Configuration Tool allows Balluff transducers type BTL7-A/ E501... to be quickly and simply configured on the PC. The most significant features are: Online display of the current position of the magnet Graphical support for setting the functions and curves Display of information about the connected transducer Selectable number formats and units for display Resetting to factory settings is possible Calibration device can be disabled Demo mode without having a transducer connected System requirements Standard PC Windows 2000/XP/Vista Screen resolution at least 1024 768 pixels 10 MB available hard disk space Java Runtime Environment (JRE) Version 1.4.2 or higher http://java.sun.com/ getjava USB port Connecting the USB communication box For model BTL7-A/E501M...-S32/S115 transducers the communications box can be installed between the transducer and the controller. The communications box is connected to the PC using a USB cable. USB communications box BTL7-A-CB01-USB-S32, for BTL7-A/E501... with S32 connector BTL7-A-CB01-USB-S115, for BTL7-A/E501... with S115 connector BTL7-A-CB01-USB-KA, for BTL7-A/E501... with cable connection Scope of delivery: USB communications box Cable set Short user's guide
BTL7
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
The PC software and associated manual can be obtained in the Internet at www.balluff.com/ downloads-btl7. www.balluff.com 13
Micropulse Transducer
Hassle-free service Cylinder-mounted transducers are often located in difficult to access spots. If a transducer is damaged or fails, replacing the complete transducer with head and waveguide is often a difficult and expensive proposition.
Should a problem occur in the electronics of the Micropulse transducer, the electronics head can be easily and quickly ex-changed for a new one. The fluid circuit also remains intact, with no draining necessary.
Ordering code Material Weight Magnet traverse velocity Operating temperature/Storage temperature Order code PA 60 glass fiber reinforced Material Weight Magnet traverse velocity Operating temperature/Storage temperature
Installation Example: Style B M181.5: When using magnetizable material, take the measures shown below.
Sealing is accomplished at the flange contact surface for the M181.5 thread using the provided O-Ring 15.4 2.1.
O-ring groove
Magnet
Non-magnetizable spacer
14
Accessories
Magnet BTL7 Rod Magnet BTL7 Rod Magnet BTL7 Rod
Micropulse Transducer
Magnet BTL7 Rod
BTL7
BTL-P-1013-4R Al approx. 12 g any 40...+100 C BTL-P-1013-4R-PA PA 60 glass fiber reinforced approx. 10 g any 40...+100 C
BTL-P-1012-4R Al approx. 12 g any 40...+100 C BTL-P-1012-4R-PA PA 60 glass fiber reinforced approx. 10 g any 40...+100 C
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
M181.5 mounting nut Order designation: BTL-A-FK01-E-M181,5 3/4"-16 UNF mounting nut Order designation: BTL-A-FK01-E-3/4"-16 UNF www.balluff.com
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com.
15
Micropulse Transducer
Connectors for Series Type
Ordering code
BKS-S 32M-_ _
BKS-S 32M-C-_ _ max. 0.5 mm Nickel plated brass CuZn 0.8 m Au PG 9 6...8 mm LifgY+LifgY, FC-11Y 80.25 mm IP 67 (when attached)
BKS-S 33M-_ _
Crimp contacts Solder connection max. 0.75 mm2 Housing material Nickel plated brass Contacts CuZn Contact finish 0.8 m Au Cable strain relief PG 9 Cable diameter min. 6...8 mm Cable LifgY+LifgY, FC-11Y No. of wires cross section 80.25 mm Enclosure rating per IEC 60529 IP 67 (when attached) Please indicate cable length to ordering code! Code 00 for self-assembly (please use shielded cable). 02 = Length 2 m 15 = Length 15 m 05 = Length 5 m 20 = Length 20 m 10 = Length 10 m 25 = Length 25 m
max. 0.75 mm2 ZnAlCu1 nickel plated CuZn 0.8 m Au PG 9 6...8 mm LifgY+LifgY, FC-11Y 80.25 mm IP 67 (when attached)
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com. BTL7-A/E/C/G1...-S32/KA Function Pin 1 2 3 4 5 6 7 8 Color YE GY PK RD GN BU BN WH BTL7-A110 0 V Output 10...0 V La (programming input) 0...10 V GND +24 V DC Lb (programming input) BTL7-E100 BTL7-E170 BTL7-C100 BTL7-C170 4...20 mA 20...4 mA 0...20 mA 20...0 mA 0 V Output 0 V Output La (programming input) GND +24 V DC Lb (programming input) La (programming input) GND +24 V DC Lb (programming input) BTL7-G110 0 V Output 10...10 V La (programming input) 10 ... 10V GND +24 V DC Lb (programming input)
Micropulse Transducer
BTL7
Stainless steel cover nut Stainless steel cover nut
BKS-S 78M-C-00
BKS-S232-PU-_ _
BKS-S233-PU-_ _
Programming
IP 67 (when attached)
Micropulse+, BTL7-A/E501...-S32/KA Function Pin 1 2 3 4 5 6 7 8 Color YE GY PK RD GN BU BN WH BTL7-A501 0 V (factory settings) 0V 10...0 V (factory settings) La (communication line) 0...10 V (factory settings) GND +24 V DC Lb (communication line) BTL7-E501 4...20 mA (factory settings) 0V 20...4 mA (factory settings) La (communication line) (factory settings) GND +24 V DC Lb (communication line) 17
www.balluff.com
Micropulse Transducer
Connectors for Series Type
Ordering code Screw terminal Housing material Contacts Contact finish Cable strain relief Cable diameter Enclosure rating per IEC 60529 Knurled coupling ring Finish O-Ring
BKS-S115-PU-_ _
BKS-S116-PU-_ _
BKS-S115-00 max. 0.75 mm2 Nickel plated brass CuZn PG 9 6...8 mm IP 67 (when attached)
Viton
Cable No. of wires conductor cross section Type Conductor configuration Outer diameter Min. bending radius Please indicate cable length to ordering code! Code 00 for user assembly (please use shielded cable). 02 = Length 2 m 15 = Length 15 m 05 = Length 5 m 20 = Length 20 m 10 = Length 10 m 25 = Length 25 m BTL7-A/E/C/G...-S115 Function Pin 1 2 3 4 5 6 7 8 Color YE GY PK RD GN BU BN WH
Molded-on PUR 80.25 mm2 LIF2Y-FC-11Y-0 320.2 mm 6.6 0.2 mm dynamic 5 D, static 3 D
BTL7-A110 BTL7-E100 BTL7-E170 0V 0V 0V 0V 10...0 V La (programming input) La (programming input) 0...10 V 4...20 mA 20...4 mA GND GND +24 V DC +24 V DC Lb (programming input) Lb (programming input)
BTL7-C100 BTL7-C170 0V 0V
BTL7-G110 0V 0V 10...10 V La (programming input) La (programming input) 0...20 mA 20...0 mA 10 ... 10V GND GND +24 V DC +24 V DC Lb (programming input) Lb (programming input)
BTL7-A/E501...-S115 Function Pin 1 2 3 4 5 6 7 8 Color YE GY PK RD GN BU BN WH BTL7-A501 0V 0V 10...0 V (factory settings) La (communication line) 0...10 V (factory settings) GND +24 V DC Lb (communication line) BTL7-E501 0V 0V 20...4 mA (factory settings) La (communication line) 4...20 mA (factory settings) GND +24 V DC Lb (communication line)
Note! Before construction, installation and startup please familar yourself with the user's guide to be founded at www.balluff.com.
Micropulse Transducer
HALT High Accelerated Lifetime Test Highest function security over years
HALT tests during the product development phase mean: "Detecting weaknesses early and eliminating them" The result is linear displacement systems and sensors of the highest quality and reliability which will continue to perform with the same safety and precision for years to come. Their use increases equipment up time, prevents service and repair costs and achieves significantly greater efficiency. Rapid temperature cycles from 100 C to +200 C and vibration loads between 10 C and 50 C can simulate aging of a sensor. Using this procedure the products are tested for their specifications to determine the re-liability, load capacity and life expectancy of the sensor. The sample is intentionally destroyed so that we can immediately improve the first component to fail. In the HALT system both sensors and transducers can be tested.
BTL7
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
Technical Data HALT System Manufacturer Frequency spectrum Acceleration Excitation Temperature range Temperature gradient Electrical power Procedure
Thermotron Industries USA 2...10000 Hz up to 50 g 9 pneumatic cylinders, noise spectrum, 3-axis, 3 linear and 3 rotary degrees of freedom 100 C...+200 C 70 K/min 96 kW Electric heater, liquid nitrogen for cooling
www.balluff.com
19
Micropulse Transducer
The following tests can be performed on this equipment: Sinusoidal testing Noise testing Shocks in addition one equipment if fitted with an FFT analyzer. Tests can be performed to the following standards: MIL STD 202 EN 60068-2-6 EN 60068-2-27 EN 60068-2-29 EN 60068-2-64 DIN EN 50155 IEC/EN 61373 GL 2001
20
Test equipment in the test laboratory Tests 1. Electro-magnetic Immunity from discharge of static electricity compatibility (EMC) (EN 61000-4-2) Immunity from electro-magnetic fields (EN 61000-4-3) Test equipment ESD generator ESD 30C, EM test with IEC finger and relay discharge module GTEM cell 1500, MEB Signal generator SMH, Rohde & Schwarz HF amplifier model 100W1000M1, AR HF amplifier model CBA9429, SCHAFFNER HF circuit network RFSN, SCHAFFNER Wattmeter NRVS, Rohde & Schwarz Wattmeter head NRV-Z 51, Rohde & Schwarz Directional coupler RK 100, MEB Directional coupler C6187, VERLATONE Field strength measurement system HI-6005, Holaday Software MEB IMM, SCHAFFNER Burst generator EFT 500, EM-Test Capacitive coupler HFK, EM-Test Hybrid generator CE-SURGE, Hilo-Test Coupling / decoupling network CDN 104 Coupling / decoupling network CDN 202 Signal generator SMH, Rohde & Schwarz HF amplifier model 150A100A, AR Coupling / decoupling network M2, MS3, S4, S9, AF2, AF4, RJ45/5 EM injection clamp F-203I-23mm, FCC Software MEB IMM, Schaffner MEB Self-built test equipment, Balluff GmbH
BTL7
Immunity from rapid transient interference (bursts) (EN 61000-4-4) Immunity from abrupt voltage surges (EN 61000-4-5) Immunity from mains-borne highfrequency interference (EN 61000-4-6)
General data Analog interface Programming Installation notes Magnet Connectors Testing Laboratory
Immunity from magnetic fields with power transmission frequencies (EN 61000-4-8) Immunity from voltage dips, short breaks in power Self-built test equipment, Balluff GmbH supply and voltage fluctuations (EN 61000-4-11) Radiated emissions (EN 55011) Mains-borne emissions (EN 55011) Emissions, HF magnetic field (DIN EN 300 330-1)
GTEM cell 1500, MEB Measurement logger SM41, MEB Software, MEB Measurement logger ESHS 30, Rohde & Schwarz Network simulator ESH3-Z5, Rohde & Schwarz Shield Cubicle Frame antenna HLA6120, SCHAFFNER Measurement logger ESHS 30, Rohde & Schwarz Shield Cubicle
2. Product-specific tests
Making capacity / breaking capacity (EN 60947-5-2) Self-built test equipment, Balluff GmbH Self-built test equipment, Balluff GmbH Testing cable anchoring of devices with integral connection cables (EN 60947-5-2) Self-built test equipment, Balluff GmbH Short circuit testing (EN 60947-5-2) Shock, sinusoidal and noise testing Shock and vibration equipment, model SA15-S092-PB and model H560B-24-LP, Unholtz-Dickie with software modules for: Sinusoidal vibrations Shocks Noise tests Signal analysis X-ray inspection equipment RTX 113, HEEB-INOTEC
4. Other
X-ray analysis
www.balluff.com
21
Service
BTL
AT
BTL
BTL BTL
K H
B J
BTL
Series
Profile P
Profile A1
Rod B
Rod BTL7
Rod NEX
Rod PEX
Internal fitting version e.g. in hydraulic cylinders External mounting e.g. on machine frames For use in explosion hazard areas Magnet Interfaces Analog voltage 0...10 V, 10...0 V, 10 V...+10 V Analog current 4...20 mA, 0...20 mA SSI SSI-SYNC CANopen DeviceNet PROFIBUS-DP Start/Stop pulse interface starting page P.1 AT.1 B.1 K.H. 1 EX.4 EX.8 floating/guided floating ring or float ring or float Pressure-proof "d" Zone 0, Zone 1, ATEX ring or float
Ignition class Dust protection "n" Zone 2 zone 22 ring or float ring or float
SMARTSENS MICROPULSE
22
Object Detection Sensor Line Inductive Sensors DC 3-/4-wire Inductive Sensors DC 2-wire Inductive Sensors AC/DC Inductive Sensors with special properties Sensors for Pneumatic Cylinders Magnetic Field Sensors Capacitive Sensors Photoelectric Line Diffuse energetic with fore- and background suppression Retro-reflective Sensors Through-beam Sensors (emitter/receiver) Fiberoptic Systems Slot Sensors Optical Window Sensors Light Grids Contrast Sensor Luminescence Sensors Color Sensors Photoelectric Distance Sensors Mechanical Line Mechanical Multiple and Single Position Switches Mechanical Multiple and Single Position Switches to DIN EN 60204-1/VDE 0113 Mechanical Multiple and Single Position Switches with forced opening Mechanical Multiple Position Switches with quick-change plunger block Inductive Multiple and Single Position Switches Inductive Multiple and Single Position Switches with extended switching distance Mechanical Wireless Single Position Switches Mixed Assembly Multiple Position Switches Linear Position Sensing Linear Position Sensing Micropulse Transducer BTL profile series Micropulse Transducer BTL AT series Micropulse Transducer BTL rod series Micropulse Transducer BTL compact rod series Micropulse Processors, BUS modules Magnetic Linear Encoder Systems BML Incremental and Absolute Encoders BDG/BRG Inductive Linear Position Sensor BIW Inductive Distance Sensors BAW Magneto-Inductive Distance Sensors BIL Photoelectric Distance Sensors BOD Industrial Identification Industrial Identification Industrial RFID Systems BIS C Industrial RFID Systems BIS L Industrial RFID Systems BIS M Industrial RFID Systems BIS S Vision Sensor BVS Industrial Networking and Connectivity Industrial Networking and Connectivity Connectors BKS Splitter Boxes BSB Valve Connectors BNI IO-Link Remote Inductive Transmission Systems BUS Systems Wireless Electrical Devices Mechanical Accessories Mechanical Accessories Attachments Mounting System BMS Please check and return by fax!
Object Detection
Industrial Identication
Mechanical Accessories
Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Phone +49 7158 173-0 Fax +49 7158 5010 [email protected]