Servo drive 3 x 400-480V 8.8A 4kW, line filter, braking resistor and electronic secure restart inhibit integrated Accessories
ACOPOS plug-in module, CAN interface ACOPOS plug-in module, ETHERNET Powerlink interface ACOPOS plug-in module, EnDat encoder interface ACOPOS plug-in module, resolver interface ACOPOS plug-in module, incremental encoder and SSI absolute encoder interface ACOPOS plug-in module, 8 digital I/O configurable in pairs as 24V input or as output 400/100mA, 2 digital outputs 2A, Order TB712 terminal block separately ACOPOS plug-in module, 2 analog inputs 10V, 2 digital I/O points which can be configured as a 24V input or 45mA output, Order TB712 terminal block separately ACOPOS plug-in module, CPU, x86 100 MHz Intel compatible, 8 MB DRAM, 32 kB SRAM, exchangeable application memory: Compact Flash, 1 CAN interface, 1 Profibus-DP Slave interface, 1 RS232 interface, order program memory separately! ACOPOS plug-in module, CPU, ARNC0, x86 100 MHz Intel compatible, 16 MB DRAM, 32 kB SRAM, exchangeable application memory: Compact Flash, 1 CAN interface, 1 Profibus-DP slave interface, 1 RS232 interface, order application memory separately! 24 VDC power supply, 3-phase, 20 A, input 400..500 VAC (3 phases), wide range, DIN rail mounting
8AC131.60-1
8AC140.60-1
8AC140.61-2
0PS320.1
43
Servo drive 3 x 400-480V 4.4A 2kW, line filter, braking resistor and electronic secure restart inhibit integrated
Frequency Installed Load Starting Current at 400 VAC Switch-on Interval Power Loss at Max. Device Power without Braking Resistor 24 VDC Supply Input Voltage 1) Input Capacitance Current Requirements 2) DC Bus DC Bus Capacitance Motor Connector Continuous Current 3) Reduction of Continuous Current Depending on Environmental Temperature 4) Mains Input Voltage: 400 VAC Switching Frequency 20 kHz Switching Frequency 10 kHz Switching Frequency 5 kHz Mains Input Voltage: 480 VAC Switching Frequency 20 kHz Switching Frequency 10 kHz Switching Frequency 5 kHz Reduction of Continuous Current Depending on Altitude Starting at 500 m Above Sea Level Peak Current Nominal Switching Frequency Maximum Motor Line Length Protective Measures Motor Holding Brake Connection Maximum Output Current Protective Measures 2.2 Aeff 235 F
24 VDC +25 % / -25 % 8200 F Max. 2.5 A + current for motor holding brake
470 F
4.4 Aeff
8.8 Aeff
0.13 Aeff per C ( 45 C) No reduction No reduction 0.13 Aeff per C ( 35 C) No reduction No reduction
0.18 Aeff per C ( 30 C) 0.18 Aeff per C ( 54 C) No reduction 0.18 Aeff per C ( 18 C) 0.18 Aeff per C ( 48 C) No reduction
0.44 Aeff per 1000 m 24 Aeff 25 m Short circuit and ground fault protection
44
Table 11: Technical data for ACOPOS 1022, 1045, 1090 (Forts.)
45
Yes No
Table 11: Technical data for ACOPOS 1022, 1045, 1090 (Forts.)
1) When using motor holding brakes, the valid input voltage range is reduced. The input voltage range should be selected so that the proper supply voltage for the motor holding brake can be maintained. 2) The current requirements depend on the configuration of the ACOPOS servo drive. 3) Valid in the following conditions: Mains input voltage 400 VAC, nominal switching frequency, 40 C environmental temperature, installation altitudes < 500 m above sea level. 4) The nominal switching frequency values for the respective ACOPOS servo drive are marked in bold. 5) Continuous operation of ACOPOS servo drives at environmental temperatures ranging from 40 C to max. 55 C is possible (taking the continuous current reductions listed into consideration), but results in a shorter lifespan. 6) Continuous operation of ACOPOS servo drives at altitudes ranging from 500 m to 2000 m above sea level is possible (taking the continuous current reductions listed into consideration). Additional requirements are to be arranged with B&R.
46
80 1)
Outgoing air
235.5
361
320
35
71.5
20
80 1)
Incoming air
Figure 16: Dimensional diagram and installation dimensions for ACOPOS 1022, 1045, 1090
1) For proper air circulation, at least 80 mm has to be left free above and below the ACOPOS servo drive.
109
Chapter 3 Installation
Chapter 5 Wiring
1. General Information
1.1 Electromagnetic Compatibility of the Installation
1.1.1 General Information If the guidelines for elecromagnetic compatibility of the installation are followed, ACOPOS servo drives meet EMC guidelines 89/336/EWG and low-voltage guidelines 73/23/EWG. They meet the requirements for harmonized EMC product standard IEC 61800-3:1996 + A11:2000 for industry (second environment). Additional EMC measures must be implemented by the manufacturer of machines or systems if the product standards for the machine has lower limits or if the machine should conform to generic standard IEC 61000-6-4. Additional EMC measures may also be needed for machines with a large number of ACOPOS servo drives. The installation of a central line filter is mostly sufficient in such cases. Proof of conformity to the necessary limits must be provided according to the documentation for use of the EMC guidelines from the manufacturer or distributor of the machine or system. Additional EMC measures are needed when operating ACOPOS servo drives in living area or when connecting ACOPOS servo drives to a low voltage system which supplies buildings in living areas without an intermediate transformer (first environment).
147
Chapter 5 Wiring
Wiring General Information 1.1.2 Installation Notes 1) The switching cabinet or the system must be constructed appropriately. 2) To prevent the effects of disturbances, the following lines must be properly shielded: motor lines encoder cables control lines data cables
3) Inductive switching elements such as contactors or relays are to be equipped with corresponding suppressor elements such as varistors, RC elements or damping diodes. 4) All electrical connections are to be kept as short as possible. 5) Cable shields are to be attached to the designated shield terminals and the plug housing. 6) Shielded cables with copper mesh or tinned copper mesh are to be used. Twisting or extending the protective mesh using single conductors is not allowed. 7) Unused cable conductors are to be grounded on both sides if possible.
148
Wiring General Information The ground connections and shield connections have to be made as illustrated in the following diagram.
Q1 L1 3 * 400 - 480 VAC L2 L3 50/60 Hz PE
1 3
2 4
2 3 1 4
PE
+24 V 0V +24 V
1 2 3
4 5 6 7 8
+24 V 0V
9 10 11 12 13
+24 V
14 15 16 17
0V
18
Trigger1 Quickstop/Trigger2 COM (1, 2) Shield Limit+ LimitRef Enable Enable X1 COM (8, 9) COM (8, 9) n.c. +24V out / 0.5A +24V +24V COM (5-7, 13-15) COM (5-7, 13-15) COM (5-7, 13-15)
X2
X3
ACOPOS
Slot 1
Slot 2
Slot 3
Slot 4
+DC
X4a
S3 S4 S1 S2
12...EnDat 6...Resolver
PE
L1 L2 L3
RB+ RB-
X4b
B+ BT+ T-
X5
PE
X6
PE
1
U V W
Chapter 5 Wiring
M
T
RB
149