Annacivil Blog: DOWNLOADED FROM Http://annacivil - TK

Download as pdf or txt
Download as pdf or txt
You are on page 1of 0

A

N
N
A
C
I
V
I
L

B
L
O
G
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
THIS PAGE IS
BLANK
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Copyright 2006 New Age International (P) Ltd., Publishers
Published by New Age International (P) Ltd., Publishers
All rights reserved.
No part of this ebook may be reproduced in any form, by photostat, microfilm,
xerography, or any other means, or incorporated into any information retrieval
system, electronic or mechanical, without the written permission of the publisher.
All inquiries should be emailed to [email protected]
ISBN (10) : 81-224-2332-9
ISBN (13) : 978-81-224-2332-7
PUBLISHING FOR ONE WORLD
NEW AGE INTERNATIONAL (P) LIMITED, PUBLISHERS
4835/24, Ansari Road, Daryaganj, New Delhi - 110002
Visit us at www.newagepublishers.com
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C9\N-HYDRO\HYD-TIT.PM5 IV
In this new Edition, two more Chapters are included, i.e.,
Chapter 17:Instantaneous Unit Hydrograph (IUH) with Clark and Nash Models illus-
trated with Workedout Examples from field data.
Chapter 18:Cloud Seeding, the technique and operation being profusely illustrated with
actual case histories in India and Russia.
Also, some more illustrative Field Examples are included under Infiltration, Storm Cor-
relation, Gumbels and Regional Flood Frequency.
All, with a good print, sketches being neatly redrawn.
Comments are always welcome and will be incorporated in the succeeding editions.
H.M. Raghunath
PREFACE TO THE SECOND EDITION
( v )
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
THIS PAGE IS
BLANK
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C9\N-HYDRO\HYD-TIT.PM5 V
Hydrology is a long continuing hydroscience and much work done in this field in the past,
particularly in India, was of empirical nature related to development of empirical formulae,
tables and curves for yield and flood of river basins applicable to the particular region in which
they were evolved by investigators like Binnie, Barlow, Beale and Whiting, Strange, Ryves,
Dicken, Inglis, Lacey, Kanwar Sain and Karpov, etc.
In this book, there is a departure from empiricism and the emphasis is on the collection
of data and analysis of the hydrological factors involved and promote hydrological design on
sound principles and understanding of the science, for conservation and utilisation of water
resources. Hydrological designs may be made by deterministic, probabilistic and stochastic ap-
proaches but what is more important is a matured judgement to understand and avoid what is
termed as unusual meteorological combination.
The book is written in a lucid style in the metric system of units and a large number of
hydrological design problems are worked out at the end of each article to illustrate the princi-
ples of analysis and the design procedure. Problems for assignment are given at the end of each
Chapter along with the objective type and intelligence questions. A list of references is included
at the end for supplementary reading. The book is profusely illustrated with sketches and is not
bulky.
The text has been so brought to give confidence and competence for the reader to sit for
a professional examination in the subject or enable him to take up independent field work as a
hydrologist of a River basin or sub-basin.
The text is divided into Fundamental and Advanced topics and Appendices to fit the
semester-hours (duration) and the level at which the course is taught.
Degree and Post-degree students, research scholars and professionals in the fields of
Civil and Agricultural Engineering, Geology and Earth Sciences, find this book useful.
Suggestions for improving the book are always welcome and will be incorporated in the
next edition.
H.M. Raghunath
PREFACE TO THE FIRST EDITION
( vii )
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
THIS PAGE IS
BLANK
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Preface to the Second Edition (v)
Preface to the First Edition (vii)
PART A-FUNDAMENTAL HYDROLOGY
1 Introduction 1
1.1 Worlds Water Resources 3
1.2 Water Resources of India 3
1.3 Hydrological Study of Tapti Basin (Central India) 5
1.4 Hydrology and Hydrologic Cycle 11
1.5 Forms of Precipitation 13
1.6 Scope of Hydrology 14
1.7 Hydrological Data 14
1.8 Hydrologic Equation 15
2 Precipitation 17
2.1 Types of Precipitation 17
2.2 Measurement of Precipitation 18
2.3 Radars 22
2.4 Rain-gauge Density 22
2.5 Estimates of Missing Data and Adjustment of Records 23
2.6 Mean Areal Depth of Precipitation (P
ave
) 26
2.7 Optimum Rain-gauge Network Design 31
2.8 Depth-Area-Duration (DAD) Curves 33
2.9 Graphical Representation of Rainfall 36
2.10 Analysis of Rainfall Data 38
2.11 Mean and Median 43
2.12 Moving Averages Curve 48
2.13 Design Storm and PMP 49
2.14 Snow Pack and Snow Melt 49
3 Water Losses 60
3.1 Water Losses 60
3.2 Evaporation 60
CONTENTS
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C9\N-HYDRO\HYD-TIT.PM5 VII
3.3 Evaporation Pans 62
3.4 Soil Evaporation 66
3.5 Unsaturated Flow 66
3.6 Transpiration 67
3.7 Evapotranspiration 67
3.8 Hydrometeorology 70
3.9 Infiltration 70
3.10 Infiltration Indices 81
3.11 Supra Rain Technique 83
3.12 Watershed Leakage 87
3.13 Water Balance 87
4 Runoff 96
4.1 Components of Stream Flow 96
4.2 Catchment Characteristics 97
4.3 Mean and Median Elevation 101
4.4 Classification of Streams 103
4.5 Isochrones 104
4.6 Factors Affecting Runoff 104
4.7 Estimation of Runoff 106
5 Hydrographs 117
5.1 Hydrograph Components 117
5.2 Separation of Streamflow Components 120
5.3 Hydrograph Separation 122
5.4 Unit Hydrograph 124
5.5 Unit Hydrograph from Complex Storms 130
5.6 S-Curve Method 138
5.7 Bernards Distribution Graph 142
5.8 Instantaneous Unit Hydrograph 149
5.9 Synthetic Unit Hydrographs 149
5.10 Transposing Unit Hydrographs 154
5.11 Application of Unit Hydrograph 157
6 Stream Gauging 171
6.1 Methods of Measuring Stream Flow 171
6.2 Current Meter Gaugings 174
6.3 Stage-Discharge-Rating Curve 178
6.4 Selection of Site for a Stream Gauging Station 183
7 Ground Water 192
7.1 Types of Aquifers and Formations 192
7.2 Confined and Unconfined Aquifers 193
7.3 Darcys Law 195
x CONTENTS
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C9\N-HYDRO\HYD-TIT.PM5 VIII
7.4 Transmissibility 196
7.5 Well Hydraulics 196
7.6 Specific Capacity 199
7.7 Cavity Wells 200
7.8 Hydraulics of Open Wells 202
7.9 Construction of Open Wells 206
7.10 Spacing of Wells 207
8 Floods-Estimation and Control 212
8.1 Size of Floods 212
8.2 Estimation of Peak Flood 213
8.4 Flood Frequency Studies 221
8.5 Encounter Probability 225
8.6 Methods of Flood Control 238
8.7 Soil Conservation Measures 245
8.8 Flood Control Economics 247
8.9 Flood Forecasting and Warning 251
9 Flood Routing 262
9.1 Reservoir Routing 262
9.2 Stream Flow Routing 270
10 Storage, Pondage and Flow Duration Curves 280
10.1 Reservoir Mass Curve and Storage 280
10.2 Flow Duration Curves 285
10.3 Pondage 288
11 Reservoir Sedimentation 298
11.1 Sediment Movement and Deposition 298
11.2 Reduction in Reservoir Capacity 300
11.3 Reservoir Sedimentation Control 303
12 Arid, Semi-Arid and Humid Regions 306
12.1 Arid Regions 306
12.2 Semi-Arid Regions 307
12.3 Humid Regions 309
PART B-ADVANCED TOPC8
13 Linear Regression 315
13.1 Fitting Regression Equation 315
13.2 Standard Error of Estimate 316
13.3 Linear Multiple Regression 319
13.4 Coaxial Graphical Correlation of Rainfall Runoff 322
CONTENTS xi
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C9\N-HYDRO\HYD-TIT.PM5 IX
14 Statistical and Probability Analysis of Hydrological Data 327
14.1 Elements of Statistics 327
14.2 Probability of Hydrologic Events 332
15 Flood FrequencyProbability and Stochastic Methods 337
15.1 Flood Frequency Methods 337
15.2 Stochastic Method 344
15.3 Stochastic Modelling by the Partial Duration Series 344
15.4 Annual Flood PeaksRiver Ganga 358
15.5 Regional Flood-Frequency Analysis (RFFA) 361
16 Mathematical Models in Hydrology 366
16.1 Type of Mathematical Models 366
16.2 Methods of Determining IUH 371
16.3 Synthetic Stream Flow 379
16.4 Flow at Ungauged Sites by Multiple Regression 381
16.5 Reservoir Mass Curve 381
16.6 Residual Mass Curve 383
16.7 Selection of Reservoir Capacity 383
16.8 Flood Forecasting 386
16.8 Mathematical Model 389
17 Instantaneous Unit Hydrograph (IUH) 393
17.1 IUH for a Basin 393
17.2 Derivation of IUH 393
17.3 Other Methods of Derivation of IUH 394
17.4 NASH Conceptual Model 394
17.5 Clarks Model 397
17.6 Drawing Isochrones and Time-Area Diagram (TAD) 398
17.7 Clarks Method 398
18 Cloud Seeding 403
18.1 Conditions for Cloud Seeding 403
18.2 Cloud Seeding Technique 404
18.3 Cloud Seeding Operation 406
18.4 Recent Case History 406
Appendices 407
Selected References 453
Bibliography 456
Index 457
xii CONTENTS
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
PART A
FUNDAMENTAL HYDROLOGY
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
THIS PAGE IS
BLANK
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 1
Hydrology is a branch of Earth Science. The importance of hydrology in the assessment,
development, utilisation and management of the water resources, of any region is being in-
creasingly realised at all levels. It was in view of this that the United Nations proclaimed the
period of 1965-1974 as the International Hydrological Decade during which, intensive efforts
in hydrologic education research, development of analytical techniques and collection of hy-
drological information on a global basis, were promoted in Universities, Research Institutions,
and Government Organisations.
1.1 WORLDS WATER RESOURCES
The Worlds total water resources are estimated at 1.36 10
8
ha-m. Of these global water
resources, about 97.2% is salt water mainly in oceans, and only 2.8% is available as fresh
water at any time on the planet earth. Out of this 2.8% of fresh water, about 2.2% is available
as surface water and 0.6% as ground water. Even out of this 2.2% of surface water, 2.15% is
fresh water in glaciers and icecaps and only of the order of 0.01% is available in lakes and
streams, the remaining 0.04% being in other forms. Out of 0.6% of stored ground water, only
about 0.25% can be economically extracted with the present drilling technology (the remain-
ing being at greater depths). It can be said that the ground water potential of the Ganga Basin
is roughly about forty times the flow of water in the river Ganga.
1.2 WATER RESOURCES OF INDIA
The important rivers of India are shown in Fig. 1.1 and their approximate water potentials are
given below:
Water potential
Sl. no. River basin
(M ha-m)
1. West flowing rivers like Narmada and Tapti 30.55
2. East flowing rivers like Mahanadi, Godavari,
Krishna, Cauvery and Pennar 35.56
3. The Ganges and its tributaries 55.01
4. Indus and its tributaries 7.95
5. The River Brahmaputra 59.07
Total 188.14
INTRODUCTION
3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 4
4 HYDROLOGY
R
.
I
n
d
u
s
Kashmir
R
.
R
a
v
i
R
.
J
h
e
l
u
m
R
.
C
h
e
n
a
b
R
.
S
u
tle
j
H.P.
Punjab
R
.
I
n
d
u
s
China
Tibet
N
e
p
a
l
R
.
G
a
n
g
a
U.P.
R
.
J
a
m
u
n
a
R
. G
a
n
g
a
Rajasthan
R
.
I
n
d
u
s
P
a
k
i
s
t
a
n
Gujarat
R. Narm
ada
R. Tapti
Bihar
Madhya Pradesh
R.
M
aha
n
adi
O
r
is
s
a
R
.
G
o
d
a
v
a
r
i
R
. K
ris
h
n
a
Mh.
A.P.
R. Pennar
Karnataka
T
a
m
i
l
N
a
d
u
R
.
C
a
u
v
e
r
y
K
e
r
a
l
a
Sri Lanka
Indian Ocean
Arabian
Sea
Bay of Bengal
Burma
Bangla Desh
Assam
R
.
B
r
a
h
m
a
p
u
tr
a
Fig. 1.1 River basins of India
The rivers of north India are perennial (i.e., the water in sufficient quantity flows in
them throughout the year) since they receive the snow melt runoff in summer. Rivers of penin-
sular India (south India) receive only runoff due to rainfall and have a good flow only during
monsoons; many of them are either dry or have negligible flow during most of the remaining
part of the year.
The average annual rainfall (a.a.r.) of India is around 114 cm. The isohyetal map of
India (i.e., isohyets or lines joining all places having the same a.a.r.) is shown in Fig. 2.8. Based
on this a.a.r., Dr. K.L. Rao has estimated the following data.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 5
INTRODUCTION 5
Sl. no. Item Approximate volume
(M ha-m)
1. Annual rainfall over the entire country 370
2. Evaporation loss @
1
3
of item (1) above 123
3. Runoff (from rainfall) in rivers 167
4. Seepage into subsoil by balance (1){(2) + (3)} 80
5. Water absorbed in top soil layers, i.e., contribution
to soil moisture 43
6. Recharge into ground water (from rainfall) (4)(5) 37
7. Annual ground water recharge from rainfall and seepage
from canals and irrigation systems (approximate) 45
8. Ground water that can be economically extracted from
the present drilling technology @ 60% of item (7) 27
9. Present utilisation of ground water @ 50% of item (8) 13.5
10. Available ground water for further exploitation and
utilisation 13.5
The geographical area of the country (India) is 3.28 Mkm
2
and the annual runoff
(from rainfall) is 167 M ha-m (or 167 10
4
Mm
3
), which is approximately two-and half-times
of the Mississippi-Missouri river Basin, which is almost equal in area to the whole of India.
Due to limitations of terrain, non-availability of suitable storage sites, short period of occur-
rence of rains, etc. the surface water resources that can be utilised has been estimated as
only 67 M ha-m. The total arable land in India is estimated to be 1.47 Mkm
2
which is 45%
of the total geographical area against 10% for USSR and 25% for USA. India has a great
potential for agriculture and water resources utilisation. A case history of the Flood Hydrol-
ogy of Tapti Basin is given below for illustration.
1.3 HYDROLOGICAL STUDY OF TAPTI BASIN (CENTRAL INDIA)
Tapti is one of the two large rivers in central India which flows west-ward (the other one being
river Narmada) and discharge into the Arabian Sea. Tapti takes its origin in Multai Hills in
the Gavilgadh hill ranges of Satpura mountain in Madhya Pradesh, Fig. 1.2. Tapti is the most
significant flood-menacing river as far as the state of Gujarat is concerned.
The River Tapti is 720 km long and runs generally to west through Madhya Pradesh
(208 km), Maharashtra (323 km) and Gujarat (189 km) states joining the Arabian Sea in the
Gulf of Cambay approximately 20 km west of the city of Surat. The river course according to
the topographical features of its run can be divided into four sections as follows:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 6
6 HYDROLOGY
F
i
g
.

1
.
2

T
a
p
t
i

b
a
s
i
n
2
2

2
1

2
0

2
2

2
1

2
0

7
3

7
4

7
5

7
6

7
7

7
8

7
3

7
4

7
5

7
6

7
7

7
8

N
M
u
l
t
a
i
T
a
l
e
g
a
o
n
B
a
s
i
n
b
o
u
n
d
a
r
y
A
k
o
l
a
R
.
P
u
r
n
a
R
.
T
a
p
i
B
u
r
h
a
n
p
u
r
M
a
d
h
y
a
P
r
a
d
e
s
h
M
a
h
a
r
a
s
h
t
r
a
B
h
u
s
a
w
a
l
J
a
l
g
a
-
o
n
N
a
n
d
e
d
R . Y a g h u r
C
h
a
l
i
s
g
a
o
n
R
.
G
i
r
n
a
S
h
i
r
p
u
r
S
h
a
h
a
d
R
.
G
o
m
a
i
M
a
h
a
r
a
s
h
t
r
a
R
.
B
u
r
a
y R
.
P
a
n
j
h
r
a
D
h
u
l
i
a
R
.
B
o
r
i
M
a
l
e
g
a
o
n
R
i
v
e
r
T
a
p
i
K
a
k
r
a
p
a
r
w
e
i
r
K
a
d
o
d
U
k
a
i
S
u
r
a
t
G
u
j
a
r
a
t
G
u
l
f
o
f
C
a
m
b
a
y
A
r a
b
i a
n
S
e
a
B
a
s
i
n
c
h
a
r
a
c
t
e
r
i
s
t
i
c
s
A
=
6
2
2
0
0
k
m
L
=
7
2
0
k
m
(
t
h
a
l
w
e
g
)
2
b
W
=
8
6
.
5
k
m
b
=
P
=
1
8
4
0
k
m
C
o
m
p
a
c
t
n
e
s
s
C
o
e
f
f
i
c
i
e
n
t
=
2
.
0
8
F
o
r
m
f
a
c
t
o
r
=
=
0
.
1
2
k
m
2
0
1
0
1
0
2
0
k
m
0
S
c
a
l
e
A L
b
L
b
W
b
R
.
A
n
a
r
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 7
INTRODUCTION 7
The catchment areas of the river Tapti above Burhanpur and Bhusaval are 81800 and
31350 km
2
, respectively. The catchment area of the river before it enters the Gujarat state is
about 57000 km
2
, while the catchment at Surat is 61800 km
2
. Thus, most of the catchment can
be called hilly with good gradients. The important tributaries, their catchment areas and the
length of their run are given below:
Tributary Catchment River at confluence
area (km
2
) (km)
Purna 17920 282
Waghur 2352 312
Girna 9720 340
Bori 2344 386
Anar 1350 382
Panjhra 2860 400
Buray 1038 424
Gomai 1263 481
1. Section I II III IV
2. Length (km) 240 288 80 112
3. Terrain Dense forests;
hill ranges hug
the river banks,
Rocky bed and
steep banks as
the river
passes through
Satpura moun-
tain ranges
Several large
tributaries join
on both sides.
Rich fertile
plains of east and
west Khandesh
districts of
Maharastra
Hilly tract cov-
ered with for-
ests, Number of
rapids between
Kamalapur and
Kakrapur a dis-
tance of 32 km.
At Kakrapur the
river falls by
7.5 m; beyond
Kakrapur the
river widens to
about 900 m
Low flat alluvial
plains of Gujarat.
River meanders
past towns of
Kathor and Surat.
Numerous rapids
near towns of
Mandvi and Kadod
4. Catchment
area (km
2
)
1000 (above
Burhanpur)
15000
5. Average bed slope
in the reach (m/
km)
2.16 0.52 0.56 0.35
6. a.a.r. (cm) 75-150 50-75 (heavy
rainfall in Ghat
catchment of
Girna river
150 cm)
150 100-150
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 8
8 HYDROLOGY
The river Purna has the biggest catchment. The river Girna has its upper catchment in
the eastern slopes of Sahyadri mountains and joins Tapti at its 300th km, only 400 km up-
stream of Surat city. Due to heavy rainfall of 150 cm in Ghats, this tributary influences the
floods in the Tapti to a great extent.
The River Tapti drains a vast catchment of 62200 km
2
, of which 27600 km
2
are situated
in Madhya Pradesh, 32100 km
2
in Maharashtra, and 2500 km
2
in Gujarat. The average an-
nual rainfall over the catchment is 78.8 cm, the maximum being 203 cm. More than 95% of the
annual rainfall occurs during the south-west monsoon from mid-June to mid-October. The
isohyetal map of normal rainfall during monsoon period is shown in Fig. 1.3. The average
annual runoff and 75% dependable yield at Ukai is assessed to be 1.73 and 1.26 M ha-m,
respectively.
22
21
20
22
21
20
73 74 75 76 77 78 79
73 74 75 76 77 78 79
Alirajpur
Rajpipla
1
0
0
0
1
1
0
0
1
2
0
0
1
3
0
0
1
4
0
0
1
5
0
0
1
6
0
0
1
5
0
0
1
0
0
0
8
0
0
7
0
0
6
5
0
5
0
0
4
5
0
500
A
r
a
b
i
a
n
s
e
a
Nasik Aurangabad
Nekkar
4
5
0
5
0
0
6
5
0
5
0
0
7
3
0
7
5
0
7
7
0
1000
4
5
0
431
Khandwa
8
0
0
9
0
0
1
0
0
0
Tale ga on
Chandor
Nagpur
1000
900
800
R. Tapti
Fig. 1.3 Normal monsoon isohyets of Tapti basin
The map of the Tapti basin and its sub-basins are shown in Fig. 1.2. The shape of the
catchment is elongated and becomes narrow as it enters Gujarat. Some catchment character-
istics are given below:
(i) Area of the basin A = 62200 km
2
(ii) Perimeter of the basin P = 1840 km
(iii) Length of the thalweg of the mainstream L
b
= 720 km
(iv) Average width of the basin W
b
=
A
L
b
=
62200
720
= 86.5 km
(v) To find the compactness coefficient of the basin:
Radius (R) of the equivalent area is given by
R
2
= 62200 km
2
R =
62200

= 142 km
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 9
INTRODUCTION 9
Circumference of the equivalent circular area
= 2R = 2 142 = 886 km
Compactness coefficient of the basin
=
P
R 2
1840
886
=
= 2.08
(vi) From factor F
f
=
W
L
A
L
b
b b
= =
2 2
62200
720
= 0.12
Sometimes, the reciprocal of this taken as the coefficient of shape of the basin (= 8.3).
(vii) Elongation ratio E
r
=
2 2 142
720
R
L
b
=

= 0.4
Narmada and Tapti catchments, which are adjacent are often hit by storms caused by
depression originating both from the Arabian Sea and the Bay of Bengal, which cause heavy
rains resulting in high floods. The tracks of the monsoon depressions that caused heavy rains*
(25.96 cm) during August 4-6, 1968 are shown in Fig. 1.4. The Tapti catchment being not di-
rectly affected by the tracks of these storms but falling in the south-westen sector of storms,
30
25
20
15
10
65 70 75 80 85 90
6
5
4
3
2
1
Tapti
catchment
Storm track
Narmada
catchment
Bay of
Bengal
Arabian
sea
7
Fig. 1.4 Storm track of August 1968
gets a well-distributed rainfall over its entire catchment except its extreme western end, where
a steep isohyetal gradient exists due to the influence of the western Ghats. Many times the
depressions move along the river courses synchronising with the movement of floods. This
phenomenon causes devastating floods. The river widens out at the lower reach. Low tides
come as far as Surat and high tides travel very much upstream. Many times high tides and
tidal waves due to storms, synchronise with floods resulting in devastation. Particularly near
the Gulf, the water becomes a vast sheet of water extending from Narmada to Mindhola, a
*The highest flood peak of R. Tapti in 1968 was 42,500 cumec, while of R. Narmada was 58,000 cumec
in 1968 and 69,400 cumec in 1970.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 10
10 HYDROLOGY
distance of about 72 km. Therefore a proper flood warning system and raised platforms would
be necessary. The city of Surat lies between elevations +21 and +32 m. The river spills over its
banks at two places above Surat, i.e., at Dholanpardi above the National Highway and
Nanavaracha. These spills are obstructed by high embankments of railways, roads and canals
causing interruptions in these services and damages to lands and property due to inundation
of floods. The city of Surat and the surrounding fertile delta are quite low and are vulnerable
to floods.
The highest ever flood seems to have occurred in 1837; most of the heavy floods have
occurred in August and September. The recent high floods in 1959 and 1968 were catastrophic
and brought untold damages to industry, commerce and normal life of the city of Surat. An
assessment of the damages caused by these floods are given below.
Sl. Flood in No. of villages Human Cattle Damage to Houses damaged
no. the year affected casualty loss standing or destroyed
crops (ha.)
1. 1959 194 79 554 30460 14815
2. 1968 505 112 7649 38540 30606
The depth-duration and the depth-area-duration curves for the heavy storms during
August 4-6, 1968 (3 days) are shown in Fig. 1.5 and Fig. 2.15. The weighted maximum rainfall
depth for the Tapti basin up to Ukai for 1, 2, and 3 days are 11.43, 22.38, and 25.96 cm,
respectively.
The maximum representative dew point of Tapti basin during the stormperiod (Aug 4-6,
1968), after reducing to the reference level of 1000 mb, was 29.8 C and the persisting repre-
sentative dew point for the storm was 26.7 C. The moisture adjustment factor (MAF), which is
the ratio of maximum precipitable water at the storm location to the precipitable water available
during the storm period, was derived with respect to the standard level of 500 mb (by refer-
ence to the diagram given by Robert D. Fletcher of US Weather Bureau as
MAF =
Depth of maximumprecipitable water (1000 mb to 500 mb)
Depth of stormprecipitable water (1000 mb to 500 mb)
=
98 mm
80 mm
= 1.23
The storm of August 4-6, 1968 was increased by 23% to arrive at the maximum prob-
able storm (MPS) of 31.8 cm, assuming the same mechanical efficiency. This MPS with mini-
mum infiltration losses and the rainfall excesses (net rainfall or runoff) rearranged during
successive 6-hour intervals, was applied to the ordinates of the 6-hour design unit hydrograph
(derived from the 1968 flood hydrograph at Kakrapar weir at Ukai) to obtain the design flood
hydrograph, the peak of which gave the maximum probable flood (MPF) of 59800 cumec (see
example 8.4). The highest flood peak observed during 1876-1968 (93 years) was 42500 cumec
in August 1968 (Fig. 1.6). The standard project flood (SPF) recommended by the Central Wa-
ter and Power Commission (CWPC), New Delhi for the design of Ukai dam was around 48200
cumec and the design flood adopted was 49500 cumec. The MPF recommended by CWPC was
also 59800 cumec.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 11
INTRODUCTION 11
1 2 3
(Days)
25
20
15
10
5
0
R
a
i
n
f
a
l
l
d
e
p
t
h
,
(
c
m
)
Aug 1968
July 1941
Sept 1945
Sept 1904
July 1894
Sept 1959
Aug 1944
July 1896
Sept 1949
Sept 1891
Sept 1954
Aug 1958
Fig. 1.5 Depth-duration curves for heavy-rain storms of Tapti basin
For the 3-day storm of 1968, the rainfall of 25.96 cm has resulted in a surface runoff of
11.68 cm, thus giving a coefficient of runoff of
11.68
2596 .
= 0.43 for the whole catchment. During
this flood, there was a wind storm of 80 km/hr blowing over the city of Surat. There was
simultaneous high tide in the river. There was heavy storm concentration in the lower catch-
ment. The total loss due to the devastating floods of 1968 was around Rs. 100 lakhs.
In Chapter 15, the magnitudes and return periods (recurrence intervals) of the high
floods are determined by the deterministic, probabilistic and stochastic approaches using the
annual flood data of the lower Tapti river at Ukai for the 30-years period from 1939 to 1968.
The Gumbels method, based on the theory of extreme values gives a 100-year flood of 49210
cumec and hence this method can be safely adopted in the estimation of design flood for the
purpose of safe design of hydraulic structures, while the stochastic approach may give a suit-
able value of MPF.
1.4 HYDROLOGY AND HYDROLOGIC CYCLE
Hydrology is the science, which deals with the occurrence, distribution and disposal of water
on the planet earth; it is the science which deals with the various phases of the hydrologic
cycle.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 12
12 HYDROLOGY
50
45
40
35
30
25
20
15
10
5
0
0 20 40 60 80 100 120 140 160 180
Time (hr)
D
i
s
c
h
a
r
g
e
Q
(
1
0
0
0
c
u
m
e
c
)
49500 cumec
42500 cumec (1968 flood)
37300 cumec (1959 flood)
Observed flood
hydrographs (1968 & 1959)
Design flood hydrograph
25
20
15
10
5
0
0 5 10 15 20 25 30 35 40 45 50 55 60
Discharge (1000 cumec)
R
a
i
n
f
a
l
l
,
(
c
m
)
Rainfall-runoff curve
Fig. 1.6 Flood hydrographs of river Tapti at Ukai
Hydrologic cycle is the water transfer cycle, which occurs continuously in nature; the
three important phases of the hydrologic cycle are: (a) Evaporation and evapotranspiration (b)
precipitation and (c) runoff and is shown in Fig. 1.7. The globe has one-third land and two-
thirds ocean. Evaporation from the surfaces of ponds, lakes, reservoirs. ocean surfaces, etc.
and transpiration from surface vegetation i.e., from plant leaves of cropped land and forests,
etc. take place. These vapours rise to the sky and are condensed at higher altitudes by conden-
sation nuclei and form clouds, resulting in droplet growth. The clouds melt and sometimes
burst resulting in precipitation of different forms like rain, snow, hail, sleet, mist, dew and
frost. A part of this precipitation flows over the land called runoff and part infilters into the
soil which builds up the ground water table. The surface runoff joins the streams and the
water is stored in reservoirs. A portion of surface runoff and ground water flows back to ocean.
Again evaporation starts from the surfaces of lakes, reservoirs and ocean, and the cycle re-
peats. Of these three phases of the hydrologic cycle, namely, evaporation, precipitation and
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 13
INTRODUCTION 13
runoff, it is the runoff phase, which is important to a civil engineer since he is concerned with
the storage of surface runoff in tanks and reservoirs for the purposes of irrigation, municipal
water supply hydroelectric power etc.
msl
Sea water
wedge
intruded
Sea
Permeable
out crop
Sea bed
Fresh
ground water
Ground
water flow Aquifer
(pervious formation)
Ground water
flow
Ground water table
I
n
t
e
r
fa
c
e
Impervious formation
G.W.T.
Infiltration
Soil
Capillary fringe
Percolation
Ground surface
Mountainous
range
Snow
storage
Interflow
Well
Soil
Rain cloud
R a i n
Evaporation
T
ra
n
s
p
ira
tio
n
E
v
a
p
o
r
a
t
i
o
n
E
v
a
p
o
r
a
t
i
o
n
Interception
R
u
n
o
f
f
o
v
e
r
la
n
d
f
lo
w
River or
lake
Cloud
from condensa-
tion of Water
vapour
S
e
a
e
v
a
p
o
r
a
t
i
o
n
S
o
i
l
e
v
a
p
o
r
a
t
i
o
n
T
r
a
n
s
p
i
r
a
t
i
o
n
Sun
Fig. 1.7 The hydrologic cycle
1.5 FORMS OF PRECIPITATION
Drizzle a light steady rain in fine drops (0.5 mm) and intensity <1 mm/hr
Rain the condensed water vapour of the atmosphere falling in drops
(>0.5 mm, maximum size6 mm) from the clouds.
Glaze freezing of drizzle or rain when they come in contact with cold objects.
Sleet frozen rain drops while falling through air at subfreezing tempera-
ture.
Snow ice crystals resulting from sublimation (i.e., water vapour condenses
to ice)
Snow flakes ice crystals fused together.
Hail small lumps of ice (>5 mm in diameter) formed by alternate freezing
and melting, when they are carried up and down in highly turbulent
air currents.
Dew moisture condensed from the atmosphere in small drops upon cool
surfaces.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 14
14 HYDROLOGY
Frost a feathery deposit of ice formed on the ground or on the surface of
exposed objects by dew or water vapour that has frozen
Fog a thin cloud of varying size formed at the surface of the earth by
condensation of atmospheric vapour (interfering with visibility)
Mist a very thin fog
1.6 SCOPE OF HYDROLOGY
The study of hydrology helps us to know
(i) the maximum probable flood that may occur at a given site and its frequency; this is
required for the safe design of drains and culverts, dams and reservoirs, channels
and other flood control structures.
(ii) the water yield from a basinits occurence, quantity and frequency, etc; this is
necessary for the design of dams, municipal water supply, water power, river navi-
gation, etc.
(iii) the ground water development for which a knowledge of the hydrogeology of the
area, i.e., of the formation soil, recharge facilities like streams and reservoirs, rain-
fall pattern, climate, cropping pattern, etc. are required.
(iv) the maximum intensity of storm and its frequency for the design of a drainage project
in the area.
1.7 HYDROLOGICAL DATA
For the analysis and design of any hydrologic project adequate data and length of records are
necessary. A hydrologist is often posed with lack of adequate data. The basic hydrological data
required are:
(i) Climatological data
(ii) Hydrometeorological data like temperature, wind velocity, humidity, etc.
(iii) Precipitation records
(iv) Stream-flow records
(v) Seasonal fluctuation of ground water table or piezometric heads
(vi) Evaporation data
(vii) Cropping pattern, crops and their consumptive use
(viii) Water quality data of surface streams and ground water
(ix) Geomorphologic studies of the basin, like area, shape and slope of the basin, mean
and median elevation, mean temperature (as well as highest and lowest tempera-
ture recorded) and other physiographic characteristics of the basin; stream density
and drainage density; tanks and reservoirs
(x) Hydrometeorological characteristics of basin:
(i) a.a.r., long term precipitation, space average over the basin using isohyets and
several other methods (Rainbird, 1968)
(ii) Depth-area-duration (DAD) curves for critical storms (station equipped with
self-recording raingauges).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 15
INTRODUCTION 15
(iii) Isohyetal mapsIsohyets may be drawn for long-term average, annual and
monthly precipitation for individual years and months
(iv) Cropping patterncrops and their seasons
(v) Daily, monthly and annual evaporation from water surfaces in the basin
(vi) Water balance studies of the basin
(vii) Chronic problems in the basin due to a flood-menacing river (like Tapti or Tapi
in central India) or siltmenacing river (like Tungabhadra in Karnataka)
(vii) Soil conservation and methods of flood control
1.8 HYDROLOGIC EQUATION
The hydrologic equation is simply the statement of the law of conservation of matter and is
given by
I = O + S ...(1.1)
where I = inflow
O = outflow
S = change in storage
This equation states that during a given period, the total inflow into a given area must
equal the total outflow from the area plus the change is storage. While solving this equation,
the ground water is considered as an integral part of the surface water and it is the subsurface
inflow and outflow that pose problems in the water balance studies of a basin.
OUZ
I Choose the correct statement/s in the following:
1 The hydrological cycle
(i) has beginning but does not end
(ii) has both beginning and end
(iii) occurs continuously in nature
(iv) is a water transfer cycle
(v) has three phasesprecipitation, evaporation and runoff
2 Hydrology deals with
(i) occurrence of water and formation of snow
(ii) movement of water on earth and water vapour in atmosphere
(iii) occurrence of floods and droughts
(iv) consumptive use of crops and crop planning
(v) prevention of drought
(iv) the hydrologic cycle
3 Hydrologic studies are made
(i) to determine MPF
(ii) to determine design flood for spillways and bridges
(iii) to asses the ground water potential of a basin
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD1-1.PM5 16
16 HYDROLOGY
(iv) for the preparation of land drainage schemes
(v) to determine the hydro-power potential
(iv) for irrigation and crop planning
(vii) for all the above
4 The hydrologic equation states that
(i) the inflow into the basin is equal to the outflow from the basin at any instant
(ii) the difference between inflow and outflow is the storage
(iii) subsurface inflow is equal to the subsurface outflow
(iv) the water balance over the basin = inflow outflow
II Match the items in A with items in B
A B
(i) Runoff (a) Deals with hydrologic cycle
(ii) Snow, hail (b) Water transfer cycle
(iii) Hydrology (c) Important phase of hydrologic cycle
(iv) Hydrologic cycle (d) Forms of precipitation
(v) Evaporation, precipitation and runoff (e) Law of conservation of matter
(vi) Hydrologic equation (f) Three phases of hydrologic cycle
OUE8TON8
1 Explain the hydraulic cycle in nature with the help of a neat sketch, indicating its various phases.
2 What are the basic data required for hydrological studies? Name the agencies from which the
data can be obtained?
3 What is the function of hydrology in water resources development? What are the basic hydrological
requirements for a river basin development?
4 Explain hydrologic equation.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 2
The precipitation in the country (India) is mainly in the form of rain fall though there is
appreciable snowfall at high altitudes in the Himalayan range and most of the rivers in north
India are perennial since they receive snow-melt in summer (when there is no rainfall).
2.1 TYPES OF PRECIPITATION
The precipitation may be due to
(i) Thermal convection (convectional precipitation)This type of precipiation is in the
form of local whirling thunder storms and is typical of the tropics. The air close to the warm
earth gets heated and rises due to its low density, cools adiabatically to form a cauliflower
shaped cloud, which finally bursts into a thunder storm. When accompanied by destructive
winds, they are called tornados.
(ii) Conflict between two air masses (frontal precipitation)When two air masses due
to contrasting temperatures and densities clash with each other, condensation and precipita-
tion occur at the surface of contact, Fig. 2.1. This surface of contact is called a front or frontal
surface. If a cold air mass drives out a warm air mass it is called a cold front and if a warm air
mass replaces the retreating cold air mass, it is called a warm front. On the other hand, if the
two air masses are drawn simultaneously towards a low pressure area, the front developed is
stationary and is called a stationary front. Cold front causes intense precipitation on com-
paratively small areas, while the precipitation due to warm front is less intense but is spread
over a comparatively larger area. Cold fronts move faster than warm fronts and usually over-
take them, the frontal surfaces of cold and warm air sliding against each other. This phenom-
enon is called occlusion and the resulting frontal surface is called an occluded front.
(ii) Orographic lifting (orographic precipitation)The mechanical lifting of moist air
over mountain barriers, causes heavy precipitation on the windward side (Fig. 2.2). For exam-
ple Cherrapunji in the Himalayan range and Agumbe in the western Ghats of south India get
very heavy orographic precipitation of 1250 cm and 900 cm (average annual rainfall), respec-
tively.
(iv) Cyclonic (cyclonic precipitation)This type of precipitation is due to lifting of moist
air converging into a low pressure belt, i.e., due to pressure differences created by the unequal
heating of the earths surface. Here the winds blow spirally inward counterclockwise in the
northern hemisphere and clockwise in the southern hemisphere. There are two main types of
cyclonestropical cyclone (also called hurricane or typhoon) of comparatively small diameter
of 300-1500 km causing high wind velocity and heavy precipitation, and the extra-tropical
cyclone of large diameter up to 3000 km causing wide spread frontal type precipitation.
17
PRECIPITATION
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 18
18 HYDROLOGY
Frontal surface
cold air mass
Warm air
mass
(a) Cold front (b) Warm front
Cold air
mass
Frontal surface
Warm air
mass
Warm
air
Cold air Colder air
(c) Stationary front
Low pressure
Fig. 2.1 Frontal precipitation
Sea
msl
Heavy rain
Windward
(Seaward side)
Mountainous
range
Leeward
(Landward) side
Rain-shadow area
Land
Fig. 2.2 Orographic precipitation
2.2 MEASUREMENT OF PRECIPITATION
Rainfall may be measured by a network of rain gauges which may either be of non-recording or
recording type.
50
Measuring
jar (glass)
60 cm
20 cm
55 cm
25 cm
5 cm
GL 5 cm
5 cm
GL
Masonry
foundation block
60 cm 60 cm 60 cm
12.5 cm
Rim (30 cm above GL)
Metal casing
Funnel
Glass bottle
(7.5-10 cm dia.)
Ground level
Fig. 2.3 Symons rain gauge
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 19
PRECIPITATION 19
The non-recording rain gauge used in India is the Symons rain gauge (Fig. 2.3). It con-
sists of a funnel with a circular rim of 12.7 cm diameter and a glass bottle as a receiver. The
cylindrical metal casing is fixed vertically to the masonry foundation with the level rim 30.5
cm above the ground surface. The rain falling into the funnel is collected in the receiver and is
measured in a special measuring glass graduated in mm of rainfall; when full it can measure
1.25 cm of rain.
The rainfall is measured every day at 08.30 hours IST. During heavy rains, it must be
measured three or four times in the day, lest the receiver fill and overflow, but the last meas-
urement should be at 08.30 hours IST and the sum total of all the measurements during the
previous 24 hours entered as the rainfall of the day in the register. Usually, rainfall measure-
ments are made at 08.30 hr IST and sometimes at 17.30 hr IST also. Thus the non-recording or
the Symons rain gauge gives only the total depth of rainfall for the previous 24 hours (i.e.,
daily rainfall) and does not give the intensity and duration of rainfall during different time
intervals of the day.
It is often desirable to protect the gauge from being damaged by cattle and for this
purpose a barbed wire fence may be erected around it.
Recording Rain Gauge
This is also called self-recording, automatic or integrating rain gauge. This type of rain gauge
Figs. 2.4, 2.5 and 2.6, has an automatic mechanical arrangement consisting of a clockwork, a
drum with a graph paper fixed around it and a pencil point, which draws the mass curve of
rainfall Fig. 2.7. From this mass curve, the depth of rainfall in a given time, the rate or inten-
sity of rainfall at any instant during a storm, time of onset and cessation of rainfall, can be
determined. The gauge is installed on a concrete or masonry platform 45 cm square in the
observatory enclosure by the side of the ordinary rain gauge at a distance of 2-3 m from it. The
gauge is so installed that the rim of the funnel is horizontal and at a height of exactly 75 cm
above ground surface. The self-recording rain gauge is generally used in conjunction with an
ordinary rain gauge exposed close by, for use as standard, by means of which the readings of
the recording rain gauge can be checked and if necessary adjusted.
30 cm
Receiver
Funnel
Tipping bucket
To recording
device
Measuring tube
Revolving drum
(chart mounted)
Clock mechanism
Pen
Spring
balance
Catch
bucket
Metal cover
Receiving
funnel
Fig. 2.4 Tipping bucket gauge Fig. 2.5 Weighing type rain gauge
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 20
20 HYDROLOGY
There are three types of recording rain gaugestipping bucket gauge, weighing gauge
and float gauge.
Tipping bucket rain gauge. This consists of a cylindrical receiver 30 cm diameter
with a funnel inside (Fig. 2.4). Just below the funnel a pair of tipping buckets is pivoted such
that when one of the bucket receives a rainfall of 0.25 mm it tips and empties into a tank
below, while the other bucket takes its position and the process is repeated. The tipping of the
bucket actuates on electric circuit which causes a pen to move on a chart wrapped round a
drum which revolves by a clock mechanism. This type cannot record snow.
Weighing type rain gauge. In this type of rain-gauge, when a certain weight of rain-
fall is collected in a tank, which rests on a spring-lever balance, it makes a pen to move on a
chart wrapped round a clockdriven drum (Fig. 2.5). The rotation of the drum sets the time
scale while the vertical motion of the pen records the cumulative precipitation.
Float type rain gauge. In this type, as the rain is collected in a float chamber, the float
moves up which makes a pen to move on a chart wrapped round a clock driven drum (Fig. 2.6).
When the float chamber fills up, the water siphons out automatically through a siphon tube
kept in an interconnected siphon chamber. The clockwork revolves the drum once in 24 hours.
The clock mechanism needs rewinding once in a week when the chart wrapped round the
drum is also replaced. This type of gauge is used by IMD.
203 cm
750 cm
Ring
Funnel
Base cover
Revolving drum
(Clock-driven)
Chart mounted
Pen
Clock mechanism
Float chamber
Float
Base
G.L.
Syphon
Syphon
chamber
Filter
Fig. 2.6 Float type rain gauge
The weighing and float type rain gauges can store a moderate snow fall which the op-
erator can weigh or melt and record the equivalent depth of rain. The snow can be melted in
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 21
PRECIPITATION 21
the gauge itself (as it gets collected there) by a heating system fitted to it or by placing in the
gauge certain chemicals such as Calcium Chloride, ethylene glycol, etc.
20
25
30
35
40
20
15
10
5
0
0 1 2 3 4 5 6 7 8
Time (days)
Pen reverses
direction
Curve traced by pen of
self-recording rain gauge
Total
rainfall
(cm)
Fig. 2.7 Mass curve of rainfall
China
Tibet
P
a
k
i
s
t
a
n
25 cm
5
0
cm
7
5
cm
125
cm
1
9
0
c
m
1
9
0
c
m
125
7
5
5
0
c
m
2
5
c
m
5
0
c
m
125
cm
125 cm
115 cm
90 cm
1
9
0
c
m
190 cm
1
9
0
c
m
125 cm
1
2
5
cm
7
5
c
m
7
5
c
m 7
5
c
m
50 cm
125
cm
190
250
cm
300
cm
5
0
c
m
5
0
c
m
7
5
c
m
7
5
c
m
1
2
5
c
m
7
5
c
m
3
0
0
c
m
c
m
2
5
0
1
9
0
1
2
5
A
r
a
b
i
a
n
s
e
a
Bay of
Bengal
1
9
0
c
m
2
5
0
c
m
500
cm
375
cm
190
cm
2
5
0
c
m
Bangla
desh
Burma
Sri
Lanka
Indian ocean
Isohyet
in cm
(normal annual)
7
5
c
m
Fig. 2.8 Isohyetal map of India
Automatic-radio-reporting rain-gauge
This type of raingauge is used in mountainous areas, which are not easily accessible to collect
the rainfall data manually. As in the tipping bucket gauge, when the buckets fill and tip, they
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 22
22 HYDROLOGY
give electric pulses equal in number to the mm of rainfall collected which are coded into mes-
sages and impressed on a transmitter during broadcast. At the receiving station, these coded
signals are picked up by UHF receiver. This type of raingauge was installed at the Koyna
hydro-electric project in June 1966 by IMD, Poona and is working satisfactorily.
2.3 RADARS
The application of radars in the study of storm mechanics, i.e. the areal extent, orientation and
movement of rain storms, is of great use. The radar signals reflected by the rain are helpful in
determining the magnitude of storm precipitation and its areal distribution. This method is
usually used to supplement data obtained from a network of rain gauges. The IMD has a well
established radar network for the detection of thunder storms and six cyclone warning radars,
on the east cost at Chennai, Kolkata, Paradeep, Vishakapatnam, Machalipatnam and Karaikal.
See the picture given on facing page.
Location of rain-gaugesRain-gauges must be so located as to avoid exposure to wind
effect or interception by trees or buildings nearby.
The best location may be an open plane ground like an airport.
The rainfall records are maintained by one or more of the following departments:
Indian Meteorological Department (IMD)
Public Works Department (PWD)
Agricultural Department
Revenue Department
Forest Department, etc.
2.4 RAIN-GAUGE DENSITY
The following figures give a guideline as to the number of rain-gauges to be erected in a
given area or what is termed as rain-gauge density
Area Rain-gauge density
Plains 1 in 520 km
2
Elevated regions 1 in 260-390 km
2
Hilly and very heavy 1 in 130 Km
2
preferably with 10% of the
rainfall areas rain-gauge stations equipped with the self
recording type
In India, on an average, there is 1 rain-gauge station for every 500 km
2
, while in more
developed countries, it is 1 stn. for 100 km
2
.
The length of record (i.e., the number of years) neeeded to obtain a stable frequency
distribution of rainfall may be recommended as follows:
Catchment layout: Islands Shore Plain Mountainous
areas regions
No. of years: 30 40 40 50
The mean of yearly rainfall observed for a period of 35 consecutive years is called the
average annual rainfall (a.a.r.) as used in India. The a.a.r. of a place depends upon: (i) distance
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 24
24 HYDROLOGY
(i) Station-year methodIn this method, the records of two or more stations are com-
bined into one long record provided station records are independent and the areas in which the
stations are located are climatologically the same. The missing record at a station in a particu-
lar year may be found by the ratio of averages or by graphical comparison. For example, in a
certain year the total rainfall of station A is 75 cm and for the neighbouring station B, there is
no record. But if the a.a.r. at A and B are 70 cm and 80 cm, respectively, the missing years
rainfall at B (say, P
B
) can be found by simple proportion as:
75
70
=
P
B
80
P
B
= 85.7 cm
This result may again be checked with reference to another neighbouring station C.
(ii) By simple proportion (normal ratio method)This method is illustrated by the fol-
lowing example.
Example 2.1 Rain-gauge station D was inoperative for part of a month during which a storm
occured. The storm rainfall recorded in the three surrounding stations A, B and C were 8.5, 6.7
and 9.0 cm, respectively. If the a.a.r for the stations are 75, 84, 70 and 90 cm, respectively,
estimate the storm rainfall at station D.
Solution By equating the ratios of storm rainfall to the a.a.r. at each station, the storm rain-
fall at station D (P
D
) is estimated as
8 5
75
.
=
6 7
84
9 0
70 90
. .
= =
P
D
3
The average value of P
D
=
1
3
8 5
75
90
6 7
84
90
9 0
70
90
. . .
+ +
L
N
M
O
Q
P
= 9.65 cm
(iii) Double-mass analysisThe trend of the rainfall records at a station may slightly
change after some years due to a change in the environment (or exposure) of a station either
due to coming of a new building, fence, planting of trees or cutting of forest nearby, which
affect the catch of the gauge due to change in the wind pattern or exposure. The consistency of
records at the station in question (say, X) is tested by a double mass curve by plottting the
cumulative annual (or seasonal) rainfall at station X against the concurrent cumulative values
of mean annual (or seasonal) rainfall for a group of surrounding stations, for the number of
years of record (Fig. 2.9). From the plot, the year in which a change in regime (or environment)
has occurred is indicated by the change in slope of the straight line plot. The rainfall records
of the station x are adjusted by multiplying the recorded values of rainfall by the ratio of slopes
of the straight lines before and after change in environment.
Example 2.2 The annual rainfall at station X and the average annual rainfall at 18 surround-
ing stations are given below. Check the consistency of the record at station X and determine the
year in which a change in regime has occurred. State how you are going to adjust the records
for the change in regime. Determine the a.a.r. for the period 1952-1970 for the changed regime.
Annual rainfall (cm)
Year Stn. X 18-stn. average
1952 30.5 22.8
1953 38.9 35.0
1954 43.7 30.2
1955 32.2 27.4
(contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 25
PRECIPITATION 25
1956 27.4 25.2
1957 32.0 28.2
1958 49.3 36.1
1959 28.4 18.4
1960 24.6 25.1
1961 21.8 23.6
1962 28.2 33.3
1963 17.3 23.4
1964 22.3 36.0
1965 28.4 31.2
1966 24.1 23.1
1967 26.9 23.4
1968 20.6 23.1
1969 29.5 33.2
1970 28.4 26.4
Solution
Cumulative Annual rainfall (cm)
Year Stn. X 18-stn. average
1952 30.5 22.8
1953 69.4 57.8
1954 113.1 88.0
1955 145.3 115.4
1956 172.7 140.6
1957 204.7 168.8
1958 254.0 204.9
1959 282.4 233.3
1960 307.0 258.4
1961 328.8 282.0
1962 357.0 315.3
1963 374.3 338.7
1964 396.6 374.7
1965 425.0 405.9
1966 449.1 429.0
1967 476.0 452.4
1968 496.6 475.5
1969 526.1 508.7
1970 554.5 535.1
The above cumulative rainfalls are plotted as shown in Fig. 2.9. It can be seen from the
figure that there is a distinct change in slope in the year 1958, which indicates that a change in
regime (exposure) has occurred in the year 1958. To make the records prior to 1958 comparable
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 26
26 HYDROLOGY
with those after change in regime has occurred, the earlier records have to be adjusted by
multiplying by the ratio of slopes m
2
/m
1
i.e., 0.9/1.25.
0 100 200 300 400 500 600
Cumulative annual rainfall-18 Stns. average, cm
C
u
m
u
l
a
t
i
v
e
a
n
n
u
a
l
r
a
i
n
f
a
l
l
o
f
S
t
n
.
X
,
c
m
600
500
400
300
200
100
0
1952
1954
1956
1958
1960
1962
1964
1966
1968
1970
2
.
5
1
.
8
2
Change in regime
indicated in 1958
\

Adjustment of records
prior to1958 :
0.9
1.25
S
l
o
p
e
=
=
1
.
2
5
=
m
1
2
.
5
2
S
l
o
p
e
=
=
0
.
9
=
m
2
1
.
8
2
Fig. 2.9 Double mass analysis Example 2.2
Cumulative rainfall 1958-1970
= 554.5 204.7 = 349.8 cm
Cumulative rainfall 1952-1957
adjusted for changed environment
= 204.7
0 9
125
.
.
= 147.6 cm
Cumulative rainfall 1952-1970
(for the current environment) = 497.4 cm
a.a.r. adjusted for the current regime
=
497.4 cm
19 years
= 26.2 cm.
2.6 MEAN AREAL DEPTH OF PRECIPITATION (P
ave
)
Point rainfallIt is the rainfall at a single station. For small areas less than 50 km
2
, point
rainfall may be taken as the average depth over the area. In large areas, there will be a net-
work of rain-gauge stations. As the rainfall over a large area is not uniform, the average depth
of rainfall over the area is determined by one of the following three methods:
(i) Arithmetic average methodIt is obtained by simply averaging arithmetically the
amounts of rainfall at the individual rain-gauge stations in the area, i.e.,
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 27
PRECIPITATION 27
P
ave
=
P
n
1
...(2.1)
where P
ave
= average depth of rainfall over the area
P
1
= sum of rainfall amounts at individual rain-gauge stations
n = number of rain-gauge stations in the area
This method is fast and simple and yields good estimates in flat country if the gauges
are uniformly distributed and the rainfall at different stations do not vary very widely from
the mean. These limitations can be partially overcome if topographic influences and aerial
representativity are considered in the selection of gauge sites.
(ii) Thiessen polygon methodThis method attempts to allow for non-uniform distribu-
tion of gauges by providing a weighting factor for each gauge. The stations are plotted on a
base map and are connected by straight lines. Perpendicular bisectors are drawn to the straight
lines, joining adjacent stations to form polygons, known as Thiessen polygons (Fig. 2.10). Each
polygon area is assumed to be influenced by the raingauge station inside it, i.e., if P
1
, P
2
, P
3
, ....
are the rainfalls at the individual stations, and A
1
, A
2
, A
3
, .... are the areas of the polygons
surrounding these stations, (influence areas) respectively, the average depth of rainfall for the
entire basin is given by
P
ave
=

A P
A
1 1
1
...(2.2)
where A
1
= A = total area of the basin.
The results obtained are usually more accurate than those obtained by simple arithme-
tic averaging. The gauges should be properly located over the catchment to get regular shaped
polygons. However, one of the serious limitations of the Thiessen method is its non-flexibility
since a new Thiessen diagram has to be constructed every time if there is a change in the
raingauge network.
(iii) The isohyetal methodIn this method, the point rainfalls are plotted on a suitable
base map and the lines of equal rainfall (isohyets) are drawn giving consideration to orographic
effects and storm morphology, Fig. 2.11. The average rainfall between the succesive isohyets
taken as the average of the two isohyetal values are weighted with the area between the
isohyets, added up and divided by the total area which gives the average depth of rainfall over
the entire basin, i.e.,
P
ave
=

A P
A
1 2 1 2
1 2

...(2.3)
where A
12
= area between the two successive isohyets P
1
and P
2
P
12
=
P P
1 2
2
+
A
12
= A = total area of the basin.
This method if analysed properly gives the best results.
Example 2.3 Point rainfalls due to a storm at several rain-gauge stations in a basin are
shown in Fig. 2.10. Determine the mean areal depth of rainfall over the basin by the three
methods.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 28
28 HYDROLOGY
Basin boundary
Thiessen
polygons
L
G
D
H
K
M
N
J
I
E
F
C
A
O
B
Stn.
Fig. 2.10 Thiessen polygon method, Example 2.3
Solution (i) Arithmetic average method
P
ave
=
P
n
1
=
1331cm
15 stn.
= 8.87 cm
P
1
= sum of the 15 station rainfalls.
(ii) Thiessen polygon methodThe Thiessen polygons are constructed as shown in
Fig. 2.10 and the polygonal areas are planimetered and the mean areal depth of rainfall is
worked out below:
Station Rainfall Area of influen- Product (2) (3) Mean areal
recorded, P
1
tial polygon, A
1
A
1
P
1
depth of
(cm) (km
2
) (km
2
-cm) rainfall
1 2 3 4 5
A 8.8 570 5016
B 7.6 920 6992
C 10.8 720 7776
D 9.2 620 5704
E 13.8 520 7176
F 10.4 550 5720
G 8.5 400 3400
H 10.5 650 6825
I 11.2 500 5600
J 9.5 350 3325
K 7.8 520 4056
L 5.2 250 1300
M 5.6 350 1960
P
ave
=

A P
A
1 1
1
=
66714
7180
= 9.30 cm
(contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 29
PRECIPITATION 29
N 6.8 100 680
O 7.4 160 1184
Total 1331 cm 7180 km
2
66714 km
2
-cm
n = 15 = P
1
= A
1
A
1
P
1
(iii) Isohyetal methodThe isohyets are drawn as shown in Fig. 2.11 and the mean
areal depth of rainfall is worked out below:
Zone Isohyets Mean isohyetal Area between Product Mean areal
(cm) value, P
12
isohyets, A
12
(3) (4) depth of
(cm) (km
2
) (km
2
-cm) rainfall
(cm)
1 2 3 4 5 6
I <6 5.4 410 2214
II 6-8 7 900 6300
III 8-10 9 2850 25650
IV 10-12 11 1750 19250
V >12 12.8 720 9220
VI <8 7.5 550 4120
Total 7180 km
2
66754 km
2
-cm
= A
12
= A
12
.P
12
Example 2.3 (a) The area shown in Fig. P (2.3a) is composed of a square plus an equilateral
triangular plot of side 10 km. The annual precipitations at the rain-gauge stations located at
the four corners and centre of the square plot and apex of the traingular plot are indicated in
figure. Find the mean precipitation over the area by Thiessen polygon method, and compare
with the arithmetic mean.
Solution The Thiessen polygon is constructed by drawing perpendicular bisectors to the lines
joining the rain-gauge stations as shown in Fig. P (2.3a). The weighted mean precipitation is
computed in the following table:
Area of square plot = 10 10 = 100 km
2
Area of inner square plot =
10
2
10
2

= 50 km
2
Difference = 50 km
2
Area of each corner triangle in the square plot =
56
4
= 12.5 km
2
1
3
area of the equilateral triangular plot =
1
3
(
1
2
10 10 sin 60)
=
25
3
= 14.4 km
2
P
ave
=

A P
A
1 2 1 2
1 2

=
66754
7180
= 930 cm
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 30
30 HYDROLOGY
VI
III
IV
V
IV
III
II
I
9.2 cm
8.8 cm 9.2 cm
A
D
C
10.8 cm
12 cm
E
13.8 cm
H
10.5
cm
11.2 cm
I
9.5 cm
J
1
0
c
m
8
c
m
6
c
m
6.8
N
M
5.6 cm
K
7.8 cm
Basin boundary
10.4 cm
F
1
0
c
m
8
c
m
7.6 cm
B
7.4 cm
O
8.5 cm
G
L
5.2 cm
Isohyetals
7.9 cm
P
F
Fig. 2.11 Isohyetal method, Example 2.3
10 km
60
1
0
k
m
D (80 cm)
F
(60 cm)
1
0
k
m
A (46 cm) 10 km B (65 cm)
45
45
Influence areas
10 km
E
(70 cm)
C (76 cm)
10 km
Fig. P(2.3a)
Station Area, A (km
2
) Precipitation A P P
ave
P (cm) (km
2
-cm) (cm)
A (12.5 + 14.4) 46 1238
= 26.9
B 12.5 65 813
(contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 31
PRECIPITATION 31
C 12.5 76 950 =

A P
A
.
D (12.5 + 14.4) 80 2152 =
9517
143 2 .
= 26.9 = 66.3 cm
E 50 70 3500
F 14.4 60 864
n = 6 A = 143.2 P = 397 A.P. = 9517
= 100 + 25 3
as a check
Arithmetic mean =
P
n
=
397
6
= 66.17 cm
which compares fairly with the weighted mean.
2.7 OPTIMUM RAIN-GAUGE NETWORK DESIGN
The aim of the optimum rain-gauge network design is to obtain all quantitative data averages
and extremes that define the statistical distribution of the hydrometeorological elements, with
sufficient accuracy for practical purposes. When the mean areal depth of rainfall is calculated
by the simple arithmetic average, the optimum number of rain-gauge stations to be estab-
lished in a given basin is given by the equation (IS, 1968)
N =
C
p
v
F
H
G
I
K
J
2
...(2.4)
where N = optimum number of raingauge stations to be established in the basin
C
v
= Coefficient of variation of the rainfall of the existing rain gauge stations (say, n)
p = desired degree of percentage error in the estimate of the average depth of rainfall
over the basin.
The number of additional rain-gauge stations (Nn) should be distributed in the differ-
ent zones (caused by isohyets) in proportion to their areas, i.e., depending upon the spatial
distribution of the existing rain-gauge stations and the variability of the rainfall over the
basin.
Saturated Newtork Design
If the project is very important, the rainfall has to be estimated with great accuracy; then a
network of rain-gauge stations should be so set up that any addition of rain-gauge stations will
not appreciably alter the average depth of rainfall estimated. Such a network is referred to as
a saturated network.
Example 2.4 For the basin shown in Fig. 2.12, the normal annual rainfall depths recorded
and the isohyetals are given. Determine the optimum number of rain-gauge stations to be estab-
lished in the basin if it is desired to limit the error in the mean value of rainfall to 10%. Indicate
how you are going to distribute the additional rain-gauge stations required, if any. What is the
percentage accuracy of the existing network in the estimation of the average depth of rainfall
over the basin ?
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 32
32 HYDROLOGY
Solution
Station Normal annual Difference (Difference)
2
Statistical parameters
rainfall, x (cm) (x x ) (x x )
2
x , , C
v
A 88 4.8 23.0 x =
x
n
=
464
5
B 104 11.2 125.4 = 92.8 cm
C 138 45.2 2040.0 =
( ) x x
n

2
1
D 78 14.8 219.0 =
3767 4
5 1
.

= 30.7
E 56 36.8 1360.0
n = 5 x = 464 (x x )
2
= 3767.4 C
v
=

x
=
30 7
92 8
.
.
100
= 33.1%
VI
III
IV
V
IV
III
II
I
88 cm
A
120 cm
C
138 cm
1
0
0
c
m
8
0
c
m
6
0
c
m
E
56 cm
D
78 cm
104 cm
B
1
0
0
c
m
8
0
c
m
Isohyetals
Basin boundary
Fig. 2.12 Isohyetal map, Example 2.4
Note: x = Arithmetic mean, = standard deviation.
The optimum number of rain-gauge stations to limit the error in the mean value of
rainfall to p = 10%.
N =
C
p
v
F
H
G
I
K
J
=
F
H
G
I
K
J
2
2
33 1
10
.
= 11
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 33
PRECIPITATION 33
Additional rain-gauge stations to be established =

N n = 11 5 = 6
The additional six raingauge stations have to be distributed in proportion to the areas
between the isohyetals as shown below:
Zone I II III IV V VI Total
Area (Km
2
) 410 900 2850 1750 720 550 7180
Area, as decimal 0.06 0.12 0.40 0.24 0.10 0.08 1.00
N Area in
decimal (N = 11) 0.66 1.32 4.4 2.64 1.1 0.88
Rounded as 1 1 4 3 1 1 11
Rain-gauges existing 1 1 1 1 1 5
Additional rain
gauges 3 2 1 6
These additional rain-gauges have to be spatially distributed between the different
isohyetals after considering the relative distances between rain-gauge stations, their accessi-
bility, personnel required for making observations, discharge sites, etc.
The percentage error p in the estimation of average depth of rainfall in the existing
network,
p =
C
N
v
, putting N = n
P =
331
5
.
= 14.8%
Or, the percentage accuracy = 85.2%
2.8 DEPTH-AREA-DURATION (DAD) CURVES
Rainfall rarely occurs uniformly over a large area; variations in intensity and total depth of
fall occur from the centres to the peripheries of storms. From Fig. 2.13 it can be seen that the
average depth of rainfall decreases from the maximum as the area considered increases. The
average depths of rainfall are plotted against the areas up to the encompassing isohyets. It
may be necessary in some cases to study alternative isohyetal maps to establish maximum 1-
day, 2-day, 3 day (even up to 5-day) rainfall for various sizes of areas. If there are adequate
self-recording stations, the incremental isohyetal maps can be prepared for the selected (or
standard) durations of storms, i.e., 6, 12, 18, 24, 30, 42, 48 hours etc.
Step-by-step procedure for drawing DAD curves:
(i) Determine the day of greatest average rainfall, consecutive two days of greatest
average rainfall, and like that, up to consecutive five days.
(ii) Plot a map of maximum 1-day rainfall and construct isohyets; similarly prepare
isohyetal maps for each of 2, 3, 4 and 5-day rainfall separately.
(iii) The isohyetal map, say, for maximum 1-day rainfall, is divided into zones to repre-
sent the principal storm (rainfall) centres.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 34
34 HYDROLOGY
(iv) Starting with the storm centre in each zone, the area enclosed by each isohyet is
planimetered.
(v) The area between the two isohyets multiplied by the average of the two isohyetal
values gives the incremental volume of rainfall.
(vi) The incremental volume added with the previous accumulated volume gives the
total volume of rainfall.
(vii) The total volume of rainfall divided by the total area upto the encompassing isohyet
gives the average depth of rainfall over that area.
(viii) The computations are made for each zone and the zonal values are then combined
for areas enclosed by the common (or extending) isohyets.
(ix) The highest average depths for various areas are plotted and a smooth curve is
drawn. This is DAD curve for maximum 1-day rainfall.
(x) Similarly, DAD curves for other standard durations (of maximum 2, 3, 4 day etc. or
6, 12, 18, 24 hours etc.) of rainfall are prepared.
Example 2.5 An isohyetal pattern of critical consecutive 4-day storm is shown in Fig. 2.13.
Prepare the DAD curve.
Rain-gauge stations
1
0
c
m
1
5
c
m
2
0
c
m
2
5
c
m
3
0
c
m
3
5
c
m
+
B
Storm
centres
+
A
5
0
4
5
4
0
3
5
c
m
3
0
c
m
2
5
c
m
2
0
c
m
1
5
c
m
1
0
c
m
Fig. 2.13 Isohyetal pattern of a 4-day storm, Example 2.5
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 35
PRECIPITATION 35
Solution Computations to draw the DAD curves for a 4-day storm are made in Table 2.1.
Table 2.1.Computation of DAD curve (4-day critical storm)
Storm Encom Area Isohyetal Average Area Incremen- Total Average
centre passing enclosed range isohyetal between tal volume volume depth
isohyet (km
2
) (cm) value isohyets (cm.km
2
) (cm.km
2
) (8) (3)
(cm) (1000) (cm) (km
2
) (1000) (1000) (cm)
(1000)
1 2 3 4 5 6 7 8 9
A 50 0.5 > 50 say, 55 0.5 27.5 27.5 55
40 4 4050 45 3.5 157.5 185.0 46.25
35 7 3540 37.5 3 112.5 297.5 42.5
30 29 3035 32.5 22 715.0 1012.5 34.91
B 35 2 > 35 say, 37.5 2 75.0 75.0 37.5
30 9.5 3035 32.5 7.5 244.0 319.0 33.6
A 25 82 2530 27.5 43.5 1196.2 2527.8 30.8
122 2025 22.5 40 900 3427.8 28.1
15 156 1520 17.5 34 595 4022.8 25.8
236 1015 12.5 80 1000 5022.8 21.3
Plot col. (9) vs. col. (3) to get the DAD curve for the maximum 4-day critical storm, as
shown in Fig. 2.14.
0
0
40 80 120 160 200 240 280
Area in (1000 km
2
)
A
v
e
r
a
g
e
d
e
p
t
h
c
m
10
20
30
40
50
60
4-day
storm
Fig. 2.14 DAD-curve for 4-day storm, Example 2.5
Isohyetal patterns are drawn for the maximum 1-day, 2-day, 3-day and 4-day (consecu-
tive) critical rainstorms that occurred during 13 to 16th July 1944 in the Narmada and Tapti
catchments and the DAD curves are prepared as shown in Fig. 2.15. The characteristics of
heavy rainstorms that have occurred during the period 193068 in the Narmada and Tapti
basins are given below:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 36
36 HYDROLOGY
0 20 0 40 60 80 100
Storm area (1000 km
2
)
(a) Narmada basin
A
v
e
r
a
g
e
d
e
p
t
h
(
c
m
)
50
40
30
50
20
10
0
3
-d
a
y
s
to
rm
2
-d
a
y
s
to
rm
1-day storm
Storm area (1000 km
2
)
(b) Tapti basin
A
v
e
r
a
g
e
d
e
p
t
h
(
c
m
)
0 20 40 60 100
60
50
40
30
20
10
0
3
-
d
a
y
s
to
r
m 2
-
d
a
y
s
to
r
m
1
-d
a
y
s
to
rm
Fig. 2.15 DAD-curves for Narmada & Tapti Basin for rainstorm of 4-6 August 1968
Year River basin
Maximum depth of rainfall (cm)
1-day 2-day 3-day 4-day
1316 Narmada 8.3 14.6 18.8 22.9
July Tapti 6.3 9.9 11.2 15.2
1944
46 Narmada 7.6 14.5 17.4
August Tapti 11.1 19.0 21.1
1968
89 Narmada 8.8 11.9
September Tapti 4.7 7.5
1961
2124 Narmada 4.1 7.4 10.4 12.9
September Tapti 10.9 14.7 18.0 20.0
1945
17 Narmada 3.8
August Tapti 10.4
1944
2.9 GRAPHICAL REPRESENTATION OF RAINFALL
The variation of rainfall with respect to time may be shown graphically by (i) a hyetograph,
and (ii) a mass curve.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 37
PRECIPITATION 37
A hyetograph is a bar graph showing the intensity of rainfall with respect to time
(Fig. 2.16) and is useful in determining the maximum intensities of rainfall during a particu-
lar storm as is required in land drainage and design of culverts.
16
14
12
10
8
6
4
2
0
I
n
t
e
n
s
i
t
y
o
f
r
a
i
n
f
a
l
l
i
(
c
m
/
h
r
)
00 30 60 90 120 150 180 210
Time t (min)
3.5
4.0
12.0 cm/hr
210-min. storm
8.5
4.5
3.0
Fig. 2.16 Hyetograph
A mass curve of rainfall (or precipitation) is a plot of cumulative depth of rainfall against
time (Fig. 2.17). From the mass curve, the total depth of rainfall and intensity of rainfall at any
instant of time can be found. The amount of rainfall for any increment of time is the difference
between the ordinates at the beginning and end of the time increments, and the intensity of
rainfall at any time is the slope of the mass curve (i.e., i = P/t) at that time. A mass curve of
rainfall is always a rising curve and may have some horizontal sections which indicates peri-
ods of no rainfall. The mass curve for the design storm is generally obtained by maximising the
mass curves of the severe storms in the basin.
C
u
m
u
l
a
t
i
v
e
r
a
i
n
f
a
l
l
P
,
c
m
7
6
5
4
3
2
1
0
12 AM 4 8 12 PM 4 8 12 AM 4 8 12 PM
Time t, hr
Intensity, i =

p
t

p
Mass curve of
precipitation

Fig. 2.17 Mass curve of rainfall


DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-1.PM5 38
38 HYDROLOGY
2.10 ANALYSIS OF RAINFALL DATA
Rainfall during a year or season (or a number of years) consists of several storms. The charac-
teristics of a rainstorm are (i) intensity (cm/hr), (ii) duration (min, hr, or days), (iii) frequency
(once in 5 years or once in 10, 20, 40, 60 or 100 years), and (iv) areal extent (i.e., area over
which it is distributed).
Correlation of rainfall recordsSuppose a number of years of rainfall records observed
on recording and non-recording rain-gauges for a river basin are available; then it is possible
to correlate (i) the intensity and duration of storms, and (ii) the intensity, duration and fre-
quency of storms.
If there are storms of different intensities and of various durations, then a relation may
be obtained by plotting the intensities (i, cm/hr) against durations (t, min, or hr) of the respec-
tive storms either on the natural graph paper, or on a double log (log-log) paper, Fig. 2.18(a)
and relations of the form given below may be obtained
(a) i =
a
t b +
A.N. Talbots formula ...(2.5)
(for t = 5-120 min)
(b) i =
k
t
n
...(2.6)
(c) i = kt
x
...(2.7)
where t = duration of rainfall or its part, a, b, k, n and x are constants for a given region. Since
x is usually negative Eqs. (2.6) and (2.7) are same and are applicable for durations t > 2 hr. By
taking logarithms on both sides of Eq. (2.7),
log i = log k + x log t
which is in the form of a straight line, i.e., if i and t are plotted on a log-log paper, the slope, of
the straight line plot gives the constant x and the constant k can be determined as i = k when
t = 1. Hence, the fitting equation for the rainfall data of the form of Eq. (2.7) can be determined
and similarly of the form of Eqs. (2.5) and (2.6).
On the other hand, if there are rainfall records for 30 to 40 years, the various storms
during the period of record may be arranged in the descending order of their magnitude (of
maximum depth or intensity). When arranged like this in the descending order, if there are a
total number of n items and the order number or rank of any particular storm (maximum
depth or intensity) is m, then the recurrence interval T (also known as the return period) of the
storm magnitude is given by one of the following equations:
(a) California method (1923), T =
n
m
....(2.8)
(b) Hazens method (1930), T =
n
m
1
2
...(2.9)
(c) Kimballs method, (Weibull, 1939) T =
n
m
+ 1
...(2.10)
and the frequency F (expressed as per cent of time) of that storm magnitude (having recur-
rence interval T) is given by
F =
1
T
100% ...(2.11)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 39
PRECIPITATION 39
Natural paper
i =
or i = kt
x a
t + b
Time t (min or hr)
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
dy
dx
i = kt
x
x =
dy
dx
Log-log paper
i = k
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
Time t (min or hr)
1
(a) Correlation of intensity and duration of storms
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
T
=
1
5
-y
e
a
r
T
=
1
0
-y
e
a
r
T
=
5
-y
e
a
r
T
=
1
-ye
a
r
Natural
paper
i =
kT
t
x
e
Time t (min or hr) Time t (min or hr)
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
A : High intensity for short duration
B : Low intensity for long duration
i = k
i
1

log i

log t
A
x = log
i
i
2
1
i
2

log i
log t
e =
One log
cycle of T
Log-log paper
i =
kT
t
x
e
D
e
c
r
e
a
s
i
n
g
f
r
e
q
u
e
n
c
y
T
=
5
0
-
y
e
a
r
T
=
2
0
-
y
e
a
r
T
=
1
5
-y
e
a
r
T
=
5
-y
e
a
r
T = 1-year
B
(b) Correlation of intensity, duration and frequency of storms
1
Fig. 2.18 Correlation of storm characteristics
Values of precipitation plotted against the percentages of time give the frquency curve.
All the three methods given above give very close results especially in the central part of the
curve and particularly if the number of items is large.
Recurrence interval is the average number of years during which a storm of given mag-
nitude (maximum depth or intensity) may be expected to occur once, i.e., may be equalled or
exceeded. Frequency F is the percentage of years during which a storm of given magnitude
may be equalled or exceeded. For example if a storm of a given magnitude is expected to occur
once in 20 years, then its recurrence interval T = 20 yr, and its frequency (probability of
exceedence) F = (1/20) 100 = 5%, i.e., frequency is the reciprocal (percent) of the recurrence
interval.
The probability that a T-year strom and frequency F
T
=
F
H
G
I
K
J
1
100% may not occur in
any series of N years is
P
(N, 0)
= (1 F)
N
...(2.12)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 40
40 HYDROLOGY
and that it may occur is
P
Ex
= 1 (1 F)
N
...(2.12a)
where P
Ex
= probability of occurrence of a T-year storm in N-years.
The probability of a 20-year storm (i.e., T = 20, F = 5%) will not occur in the next 10 years
is (1 0.05)
10
= 0.6 or 60% and the probability that the storm will occur (i.e., will be equalled or
exceeded) in the next 10 years is 1 0.6 = 0.4 or 40% (percent chance).
See art. 8.5 (Encounter Probability), and Ex. 8.6 (a) and (b) (put storm depth instead of
flood).
If the intensity-duration curves are plotted for various storms, for different recurrence
intervals, then a relation may be obtained of the form
i =
kT
t
x
e
... Sherman ...(2.13)
where k, x and e are constants.
i vs. t plotted on a natural graph paper for storms of different recurrence intervals
yields curves of the form shown in Fig. 2.18 (b), while on a log-log paper yields straight line
plots. By taking logarithms on both sides of Eq. (2.13),
log i = (log k + x log T) e log t
which plots a straight line; k = i, when T and t are equal to 1. Writing for two values of T (for
the same t) :
log i
1
= (log k + x log T
1
) e log t
log i
2
= (log k + x log T
2
) e log t
Subtracting, log i
1
log i
2
= x (log T
1
log T
2
)
or, x =

log
log
i
T
x = charge in log i per log-cycle of T (for the same value of t)
Again writing for two values of t (for the same T):
log i
1
= (log k + x log T) e log t
1
log i
2
= (log k + x log T) e log t
2
Subtracting log i
1
log i
2
= e(log t
1
log t
2
)
or e =
log
log
i
t
or e = slope =

log
log
i
t
e = change in log i per log cycle of t (for the same value of T).
The lines obtained for different frequencies (i.e., T values) may be taken as roughly
parallel for a particular basin though there may be variation in the slope e. Suppose, if a 1-
year recurrence interval line is required, draw a line parallel to 10year line, such that the
distance between them is the same as that between 5-year and 50-year line; similarly a 100-
year line can be drawn parallel to the 10-year line keeping the same distance (i.e., distance per
log cycle of T). The value of i where the 1-year line intersects the unit time ordinate (i.e., t = 1
min, say) gives the value of k. Thus all the constants of Eq. (2.13) can be determined from the
log-log plot of i vs. t for different values of T, which requires a long record of rainfall data.
Such a long record, will not usually be available for the specific design area and hence it
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 41
PRECIPITATION 41
becomes necessary to apply the intensity duration curves of some nearby rain gauge stations
and adjust for the local differences in climate due to difference in elevation, etc. Generally,
high intensity precipitations can be expected only for short durations, and higher the intensity
of storm, the lesser is its frequency.
The highest recorded intensities are of the order of 3.5 cm in a minute, 20 cm in 20 min
and highest observed point annual rainfall of 26 m at Cherrapunji in Assam (India). It has
been observed that usually greater the intensity of rainfall, shorter the duration for which the
rainfall continues. For example, for upper Jhelum canals (India) maximum intensities are
17.8 and 6.3 cm/hr for storms of 15 and 60 min respectively.
Example 2.5 (a) In a Certain water shed, the rainfall mass curves were available for 30 (n)
consecutive years. The most severe storms for each year were picked up and arranged in the
descending order (rank m). The mass curve for storms for three years are given below. Establish
a relation of the form i =
kT
t
x
e
, by plotting on log-log graph paper.
Time(min) 5 10 15 30 60 90 120
Accumulated
depth (mm)
for m = 1 9 12 14 17 22 25 30
for m = 3 7 9 11 14 17 21 23
for m = 10 4 5 6 8 11 13 14
Solution
Time t (min) 5 10 15 30 60 90 120 T-yr =
n
m
+ 1
Intensity
i (mm/hr)
for m = 1
9
5
60
12
10
60 56 34 22 16.6 15
30 1
1
+

~
30 yr
= 108 = 72
for m = 3
7
5
60
9
10
60
44 28 14 14 11.5
30 1
3
+

~
10 yr
= 84 = 54
for m = 10
4
5
60
5
10
60
24 16 11 8.7 7
30 1
10
+

~
3 yr
= 48 = 30
The intensity-duration curves (lines) are plotted on log-log paper (Fig. 2.18 (c)), which
yield straight lines nearby parallel. A straight line for T = 1 yr is drawn parallel to the line
T = 10-yr at a distance equal to that between T = 30yr and T = 3-yr. From the graph at T = 1-
yr and t = 1 min, k = 103.
The slope of the lines, say for T = 30-yr is equal to the change in log i per log cycle of t,
i.e., for t = 10 min and 100 min, slope = log 68 log 17 = 1.8325 1.2304 = 0.6021
~
0.6 = e.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 42
42 HYDROLOGY
400
200
100
80
50
30
20
10
8
6
5
4
1 10 100
4
10
100
400
i =
103 T
t
0.34
0.6
Log-log paper
Log cycle
of t

log i = 0.6 = e
Log cycle
of T, log i = 0.34 = x
T
=
3
0
y
r
68
55
31
17
T
=
1
y
r

T
=
3
y
r
T & t
= 1
103 = K
T
=
1
0
y
r
t (min)
i
(
m
m
/
h
r
)
Fig. 2.18. (c) Intensity-duration relationship, (Ex. 2.5 (a))
At t = 10 min, the change in log i per log cycle of T, i.e., between T = 3yr and 30yr lines
(on the same vertical), log 68 log 31 = 1.8325 1.4914 = 0.3411
~
0.34 = x.
Hence, the intensity-duration relationship for the watershed can be established as
i =
104
0.34
0.6
T
t
For illustration, for the most severe storm (m = 1, T = 30yr), at t = 60 min, i.e., after 1
hr of commencement of storm,
i =
103 30
60
0.34
0.6
( )
( )
= 28 mm/hr
which is very near to the observed value of 22 mm/hr.
A more general Intensity-DurationFrequency (IDF) relationship is of the form
Sherman i =
KT
t a
x
n
( ) +
, i in cm/hr, t in min, T yr.
where K, x, a and n are constants for a given catchment. The rainfall records for about 30 to 50
years of different intensities and durations on a basin can be analysed with their computed
recurrence interval (T). They can be plotted giving trial values of a for the lines of best fit as
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 43
PRECIPITATION 43
shown in Fig. 2.18 (b). The values of a and n may be different for different lines of recurrence
interval.
The constants can also be obtained by multiple regression model based on the principle
of least squares and solutions can be obtained by computer-based numerical analysis; confi-
dence intervals for the predictions can be developed.
Extreme point rainfall values of different durations and recurrence interval (return
period) have been evaluated by IMD and the isopluvial maps (lines connecting equal depths
of rainfall) for the country prepared.
Example 2.5 (b) A small water shed consists of 2 km
2
of forest area (c = 0.1), 1.2 km
2
of culti-
vated area (c = 0.2) and 1 km
2
under grass cover (c = 0.35). A water course falls by 20 m in a
length of 2 km. The IDF relation for the area may be taken as
i =
80
12
0.2
0.5
T
t ( ) +
, i in cm/hr, t in min and T yr
Estimate the peak rate of runoff for a 25 yr frequency.
Solution Time of concentration (in hr)
t
c
= 0.06628 L
0.77
S
0.385
, Kirpichs formula, L in km
= 0.06628 2
0.77

20
2 1000
0.385

F
H
G
I
K
J

= 0.667 hr 60 = 40 min.
i = i
c
when t = t
c
in the given IDF relation
i
c
=
80 25
40 12
0.2
0.5

+ ( )
= 21.1 cm/hr
Q
peak
= 2.78 C i
c
A, rational formula, CA = C
i
A
i
= 2.78 21.1 (0.1 2 + 0.2 1.2 + 0.35 1) = 46.4 cumec
2.11 MEAN AND MEDIAN
The sum of all the items in a set divided by the number of items gives the mean value,
i.e.,
x
=
x
n
...(2.10)
where
x
= the mean value
x = sum of all the items
n = total number of items.
The magnitude of the item in a set such that half of the total number of items are larger
and half are smaller is called the median. The apparent median for the curve in Fig. 2.21 is the
ordinate corresponding to 50% of the years. The mean may be unduly influenced by a few large
or small values, which are not truly representative of the samples (items), whereas the median
is influenced mainly by the magnitude of the main part of intermediate values.
To find the median, the items are arranged in the ascending order; if the number of
items is odd, the middle item gives the median; if the number of items is even, the average of
the central two items gives the median.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 44
44 HYDROLOGY
Example 2.6 The annual rainfall at a place for a period of 10 years from 1961 to 1970 are
respectively 30.3, 41.0, 33.5, 34.0, 33.3, 36.2, 33.6, 30.2, 35.5, 36.3. Determine the mean and
median values of annual rainfall for the place.
Solution (i) Mean
x
=
x
n
= (30.3 + 41.0 + 33.5 + 34.0 + 33.3 + 36.2
+ 33.6 + 30.2 + 35.5 + 36.3)/10
=
3439
10
.
= 34.39 cm
(ii) Median: Arrange the samples in the ascending order 30.2, 30.3 33.3, 33.5, 33.6, 34.0,
35.5, 36.2, 36.3, 41.0
No. of items = 10, i.e., even
Median =
33 6 34 0
2
. . +
= 33.8 cm
Note the difference between the mean and the median values. If 11 years of record, say
1960 to 1970, had been given, the median would have been the sixth item (central value) when
arranged in the ascending order.
Example 2.7 The following are the rain gauge observations during a storm. Construct: (a)
mass curve of precipitation, (b) hyetograph, (c) maximum intensity-duration curve and develop
a formula, and (d) maximum depth-duration curve.
Time since commencement Accumulated
of storm rainfall
(min) (cm)
5 0.1
10 0.2
15 0.8
20 1.5
25 1.8
30 2.0
35 2.5
40 2.7
45 2.9
50 3.1
Solution (a) Mass curve of precipitation. The plot of accumulated rainfall (cm) vs. time
(min) gives the mass curve of rainfall Fig. 2.19 (a).
(b) Hyetograph. The intensity of rainfall at successive 5 min interval is calculated and a
bar-graph of i (cm/hr) vs. t (min) is constructed; this depicts the variation of the intensity of
rainfall with respect to time and is called the hyetograph; 2.19 (b).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 45
PRECIPITATION 45
Time, t Accumulated P in time Intensity,
(min)
rainfall
t = 5 min
i =

P
t
60
(cm) (cm) (cm/hr)
5 0.1 0.1 1.2
10 0.2 0.1 1.2
15 0.8 0.6 7.2
20 1.5 0.7 8.4
25 1.8 0.3 3.6
30 2.0 0.2 2.4
35 2.5 0.5 6.0
40 2.7 0.2 2.4
45 2.9 0.2 2.4
50 3.1 0.2 2.4
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
T
o
t
a
l
r
a
i
n
f
a
l
l
d
e
p
t
h
(
c
m
)
mass curve traced by
self-recording rain gauge
50-min storm
0 5 10 15 20 25 30 35 40 45 50 55 60
Time t (min)

p
t
i =

p
(a) Mass curve of precipitation
1.2 cm/hr
8.4 cm/hr
2.4 cm/hr
7.2
3.6
2.4
6.0
50-min storm
Area under the curve
gives total precipitation (cm)
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
10
8
6
4
2
0
0 5 10 15 20 25 30 35 40 45 0 50
Time t (min)
(b) Hyetograph
Fig. 2.19 Graphs from recording rain-gauge data, Example 2.7
(c) Maximum depthduration curve. By inspection of time (t) and accumulated rainfall
(cm) the maximum rainfall depths during 5, 10, 15, 20, 25, 30, 35, 40, 45 and 50 min durations
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 46
46 HYDROLOGY
are 0.7, 1.3, 1.6, 1.8, 2.3, 2.5, 2.7, 2.9, 3.0 and 3.1 cm respectively. The plot of the maximum
rainfall depths against different durations on a log-log paper gives the maximum depth-dura-
tion curve, which is a straight line, Fig. 2.20 (a).
i =
17
t
0.375
b. Maximum intensity-duration curve
a. Maximum depth-duration curve
k = 17
x = 0.375
0.75
cm
Log-log paper
100
80
60
40
30
20
15
10
8
6
5
4
3
2
1.5
1
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
1 1.5 2 3 4 5 6 8 10 15 20 30 40 60 80 100
10
8
6
4
3
2
1.5
1
0.8
0.6
0.4
0.3
0.2
0.15
2.0 cm
0.1
M
a
x
i
m
u
m
d
e
p
t
h
(
c
m
)
Time t (min)
Slope
Fig. 2.20 Maximum depth-duration & intensity-duration curves (Example 2.7)
(d) Maximum intensity-duration curve. Corresponding to the maximum depths obtained
in (c) above, the corresponding maximum intensities can be obtained

P
t
60, i.e., 8.4, 7.8, 6.4,
5.4, 5.52, 5.0, 4.63, 4.35, 4.0 and 3.72 cm/hr, respectively. The plot of the maximum intensities
against the different duration on a log-log paper gives the maximum intensity-duration curve
which is a straight line, Fig. 2.20 (b).
The equation for the maximum itensity duration curve is of the form
i = kt
x
Slope of the straight line plot,
x =
dy
dx
=
0.75 cm
2.00 cm
= 0.375
k = 17 cm/hr when t = 1 min
Hence, the formula becomes
i =
17
0.375
t
which can now be verified as
t = 10 min, i = 7.2 cm/hr
t = 40 min, i = 4.25 cm/hr
which agree with the observed data
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 47
PRECIPITATION 47
Example 2.8 The annual rainfall at a place for a period of 21 years is given below. Draw the
rainfall frequency curve and determine :
(a) the rainfall of 5-year and 20-year recurrence, interval
(b) the rainfall which occurs 50% of the times
(c) the rainfall of probability of 0.75
(d) the probability of occurrence of rainfall of 75 cm and its recurrence interval.
Year Rainfall Year Rainfall
(cm) (cm)
1950 50 1961 56
1951 60 1962 52
1952 40 1963 42
1953 27 1964 38
1954 30 1965 27
1955 38 1966 40
1956 70 1967 100
1957 60 1968 90
1958 35 1969 44
1959 55 1970 33
1960 40
Solution Arrange the yearly rainfall in the descending order of magnitude as given below. If
a particular rainfall occurs in more than one year, m = no. of times exceeded + no. of times
equalled.
Year Rainfall Rank (m)
Frequency
P (cm) (no. of times P)
F =
m
n + 1
100%
1967 100 1 4.6
1968 90 2 9.1
1956 70 3 13.6
1951, 1957 60 5 22.7
1961 56 6 27.3
1959 55 7 31.8
1962 52 8 36.4
1950 50 9 40.9
1969 43 10 45.5
1963 42 11 50.0
1952 1960
1966
, U
V
W
40 14 63.7
1955, 1964 38 16 72.8
1958 35 17 77.3
1970 33 18 81.8
1954 30 19 86.4
1953, 1965 27 21 95.5
Total x = 1026 n = 21
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 48
48 HYDROLOGY
Draw the graph of P vs. F on a semi-log paper which gives the rainfall frequency curve,
Fig. 2.21. From the frequency-curve, the required values can be obtained as
(a) T = 5yr, F =
1
T
100 =
100
5
= 20% for which P = 64 cm.
T = 20 yr, F =
1
20
100 = 5% for which P = 97.5 cm
0
10
20
30
40
50
60
70
80
90
100
100 50 25 20 10 5 2 1
Semi-log paper
97.5 cm
75 cm
64 cm
48.8 cm
42.2 cm
32 cm
Frequency
curve
Mean
Median
1 1.5 2 3 4 5 6 7 8 10 15 20 30 40 50 60 80100
Frequency F % ( P)

A
n
n
u
a
l
r
a
i
n
f
a
l
l
P
(
c
m
)
12.4 % 37 %
75 %
Recurrence interval T-yr
8 yr
Fig. 2.21 Rainfall frequency curve (Example 2.8)
(b) For F = 50%, P = 42.2 cm which is the median value, and the mean value
x
=
x
n
=
1026
21
= 48.8 cm
which has a frequency of 37%.
(c) For a probability of 0.75 F = 75% for which P = 32 cm
(d) For P = 75 cm, F = 12.4%, T =
1
F
100 =
100
12 4 .
= 8 yr
and its probability of occurrence = 0.124
2.12 MOVING AVERAGES CURVE
If the rainfall at a place over a number of years is plotted as a bar graph it will not show any
trends or cyclic patterns in the rainfall due to wide variations in the consecutive years. In
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 49
PRECIPITATION 49
order to depict a general trend in the rainfall pattern, the averages of three or five consecutive
years are found out progressively by moving the group averaged, one year at a time. In Fig.
2.22, the 21-years of rainfall records at a place given in Example 2.8 are shown. The first five
years of record are averaged as (50 + 60 + 40 + 27 + 30)/5 = 207/5 = 41.4 cm and this average is
plotted at the mid-point of the group. The next point is obtained by omitting the first and
averaging the 2 to 6 years of record, again plotting the average i.e., (207 50 + 38)/5 = 39 cm at
the midpoint of this group, and so on as shown in Fig. 2.22. Thus, a 5-year moving mean curve
is obtained in which the wide variations in the consecutive years are smoothed out. A 3-year or
5-year moving mean curve is useful in identifying the long term trends or patterns in the
rainfall at a place.
5-year moving mean curve trend line
1
9
5
0
5
1
5
2
5
3
5
4
5
5
5
6
5
7
5
8
5
9
1
9
6
0
6
2
6
1
6
3
6
4
6
5
6
6
6
7
6
8
6
9
1
9
7
0
Years
100
80
60
40
20
0
P
r
e
c
i
p
i
t
a
t
i
o
n
P
(
c
m
)
Fig. 2.22 Trends from moving mean curves (Example 2.8)
The same techniques may be applied to other hydrometeorogical parameters like tem-
perature, hours of bright sunshine, wind speeds, cloud cover, etc.
2.13 DESIGN STORM AND PMP
For the safe design of structures even a 50-year or 100-year precipitation may be inadequate
due to the unusual meteorological combinations resulting in very high precipitation. The most
critical features of several past storms are often combined, for a given frequency of occurrence,
into a single design storm (hypothetical) for the purpose of design of important structures. The
probable maximum precipitation (PMP) for a given region is the precipitation resulting from
the most critical meteorogical combinations that are considered probable of occurrence. This
concept of PMP is very important in estimating the maximum probable flood in the safe design
of flood control structures, spillways for dams, etc. PMP can be estimated by maximising the
different parameters like wind velocity, humidity etc. of an observed severe storm over the
basin. When sufficient data of storms for a given basin is not available, PMP can be estimated
from a severe storm on the adjacent basin and storm transposition.
2.14 SNOW PACK AND SNOW MELT
Snow melts due to heat from the atmosphere, from the warm rainfall and by radiation. On the
basis of measurement of snow depth and water equivalent (or density) of snow at grid stations
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 50
50 HYDROLOGY
along the snow courses, the water storage in the snow (i.e., the available snow melt) can be
determined from the formula.
d
w
= G
s
d
s
...(2.11)
where d
w
= depth of water storage in the snow
d
s
= depth of snow cover
G
s
= water equivalent (density) of snow
Water equivalent or snow density is the ratio of the volume of melt water from a sample
of snow to the initial volume of the snow sample. An average density of 0.1 for freshly fallen
snow is often assumed; however the longer the snow remains on the ground, the denser it
becomes due to packing, alternate thawing and freezing, condensation and the presence of
absorbed rainfall and melt water. Snow density will be about 0.1 at the beginning of winter
and about 0.3 at the end of winter, i.e., at the beginning of thaw. The density of snow varies
with depth and so samples must be taken at various horizons in a snow pack for determining
the water equivalent. This is usually done by a sampling tube. Snowfall may be measured
directly by an ordinary rain gauge fitted with a heating system, or by a simple snow stake, if
there is no drifting and density is determined simultaneously.
Snow surveys are made by dividing the basin into rectangular grids and determining
the snow depths and densities at depths at the grid stations. From the water equivalents thus
obtained at individual stations, the average water equivalent of the snow pack over the entire
basin can be derived by the same method used for determining the mean areal depth of rainfall.
In India, snow surveys are generally conducted in the beginning of summer, i.e., in March or
April, when snow starts melting. Many of the perennial rivers in north India are fed by snow-
melt from the Himalayan range in summer. In the Himalayan range, one-tenth of the depth of
snow is added to the depth of rainfall, as a thumb rule, to obtain the total precipitation.
Also see Appendix-A.
OUZ
I Match the items in A with items in B:
A B
(i) Cyclone (a) Optimum rain-gauge network
(ii) Frontal surface (b) Intensity of storm
(iii) Rain-gauge (c) Can not record snow
(iv) Double mass curve (d) 1 in 500 km
2
(v) Tipping bucket gauge (e) Mean areal depth of precipitation
(vi) Recording rain-gauge (f) Western Ghats (of Peninsular India)
(vii) Orographic precipitation (g) Covergence of storm
(viii) Thiessen network (h) Surface of contact between warm and
cold air masses
(ix) Raingauge density (i) Air port
(x) Coefficient of variation, C
v
(j) Change of regime of rain-gauge station
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 51
PRECIPITATION 51
II Fill up the blanks in the following:
(i) Rain-gauges are erected...... over the ground surface with their rim at .... cm above ground
surface
(ii) The three principal agencies, which maintain rain-gauges and make observations in Karnataka
are: (a) ....... (b) ........ and (c) ......
(iii) Rain-gauge readings are taken every day at .... hr IST
(iv) In coastal areas of Karnataka one rain-gauge should be erected for every ..... km
2
and .......
years (consecutive) of record are required for statistical analysis.
(v) An index of wetness of 40% in a certain area indicates a ..... year with a rainfall deflciency of
....%.
III Say True or False; if false, give the correct statement:
(i) Rain-gauges are erected perpendicular to the ground surface on which they are installed.
(ii) Cyclonic precipitation is due to convergence of storms towards a low pressure belt.
(iii) In hilly and heavy rainfall areas at least 10% of the rain-gauges should be of self-recording
type.
(iv) As the area increases, the average depth of precipitation increases for a particular storm.
(v) Generally, high intensity precipitation can be expected only for short durations, and higher
the intensity, lesser is its frequency.
(vi) The coefficient of variation for annual precipitation data is equal to the standard deviation of
the indices of wetness.
(vii) A mass curve of rainfall need not always be a rising curve.
(viii) The longer the snow remains on the ground, the less dense it becomes.
(ix) The intensity of storm is an inverse function of its duration. (false: i, iv, vii, viii)
IV Choose the correct statement/s in the following:
1 Precipitation includes
(i) rainfall (ii) snow melt
(iii) hail storm (iv) stream flow
(v) mist and fog (vi) frost
(vii) all the above
2 In a cold front
(i) cold air mass drives out a warm air mass
(ii) warm air mass replaces the retreating cold air mass
(iii) cold air and warm air masses are drawn simultaneously towards a low pressure area
(iv) the cold and warm air masses are stationary
3 Cyclonic precipitation is due to
(i) orographic lifting (ii) ocean nearby
(iii) convergence of storms towards a low pressure belt
(iv) divergence of storms (v) thermal convection
(vi) conflict between cold and warm air masses
4 A self-recording rain-gauge
(i) records by hourly depth of rain (ii) records the snow melt
(iii) records the cumulative depth of rainfall
(iv) records the rainfall intensity (v) records the onset and cessation of rainfall
(vi) records the cloud cover
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 52
52 HYDROLOGY
5 A double mass analysis is made
(i) to find the missing rainfall at a station in a particular area
(ii) to detect any change in exposure of a station
(iii) to adjust the record at a station to the changed environment
(iv) to compute the a.a.r. consistent with the changed environment
(v) for all the above purposes
6 Isohyetal method gives accurate mean areal depth of rainfall
(i) in a plain country
(ii) in a gently sloping basin
(iii) in an undulating country
(iv) in places of known storm movement
(v) in a basin consisting of plains and hills
(vi) when there are optimum number of rain-gauge stations
(vii) when the precipitation includes snowmelt
(1-exept iv; 2i ; 3iii ; 4iii, v ; 5ii, iii, iv ; 6iii, iv, v)
OUE8TON8
1 What factors you consider in selecting a site for a rain-gauge station?
2 (a) Distinguish between recording and non-recording rain-gauges, giving examples of such gauges
used in India.
(b) Which are the agencies that usually maintain rain-gauges and make observations in your
State? At what time or times in the day is the rainfall recorded?
3 What are the different forms of precipitation ? Which of them are of significance to a civil engi-
neer ?
4 (a) Explain: (i) a method for estimating the missing rainfall data at a station in a basin.
(ii) a method for testing the consistency of rainfall records at a station and necessary
adjustment.
(b) A 3-hour storm occurred at a place and the precipitations in the neighbouring rain-gauge
stations P, Q and R were measured as 3.8, 4.1 and 4.5 cm, respectively. The precipitation in
the neighbouring station S could not be measured since the rain-gauge bottle was broken.
The normal precipitation in the four stations P, Q, R and S as per IMD Bulletin were 45, 48,
53 and 50 cm, respectively. Estimate the storm precipitation at station S. (4.246 cm)
5 (a) Define rain-gauge density and explain how you would determine the optimum number of
rain-gauges to be erected in a given basin.
(b) In a certain river basin there are six rain-gauge stations, the normal annual rainfall depths
at the stations being 42.4, 53.6, 67.8, 78.5, 82.7 and 95.5 cm, respectively. Determine the
optimum number of rain-gauge stations to be established in the basin if it is desired to limit
the error in the mean value of rainfall over the catchment to 10% and indicate how you
distribute them, (7)
6 For the basin shown in Fig. P 2.23, the normal annual rainfall depths recorded and the isohyetals
are given. Determine the optimum number of rain-gauge stations to be established in the basin
if it is desired to limit the error in the mean value of rainfall to 10%. Indicate how you are going
to distribute the additional rain-gauge stations required if any. What is the percentage accuracy
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 53
PRECIPITATION 53
of the exixting network in the estimation of the average depth of rainfall over the basin. The
area between the isohyetals are given below :
Zone: I II III IV V VI Total
Area (Km
2
): 63 278 389 220 55 33 1038
(161, 1, 4, 2, 0, 1; 85.2%)
VI
III
I
II
III
IV
V
5
0
c
m
7
5
c
m
60 cm
A
F
B
86 cm
100
cm
92 cm
68 cm
G
7
5
c
m
5
0
c
m
2
5
c
m
D
45 cm
20 cm
E
C
62 cm
Fig. P2.23 Isohyetal map
7 (a) Explain three methods of determining the mean areal depth of precipitation over a basin
covered by several rain-gauge stations.
(b) Find the mean precipitation for the area shown in Fig. P 2.24 by Thiessen polygon method.
The area is composed of a square plus an equilateral triangular plot of side 2 km. Rainfall
readings are in cm at the various stations indicated. (32.33 cm)
2
k
m
D
F 15 cm
2
k
m
A 2 km B
2 km
E
C
38 cm
20 cm
10 cm
68 cm
43 cm
Rain gauge stations
Fig. P2.24 Rain-gauge network
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 54
54 HYDROLOGY
8 Thiessen polygons and isohyetal map are given in Fig. P 2.25 and P 2.26, respectively, for differ-
ent drainage basins. Areas and precipitation values are tabulated. Compute the average precipi-
tation over the basins.
Station Thiessen polygon Precipitation
area (cm)
(km
2
)
A 170 9.3
B 164 10.5
C 156 10.9
D 150 12.2
E 116 13.5
F 36 14.0
G 124 14.2
H 42 12.8
Area of basin = 958 km
2
Zone Area (km
2
)
I 56
II 192
III 420
IV 244
V 44
VI 58
Area of basin = 1014 km
2
A
9.3 cm
12.8 cm
H
G
14.2 cm
14.0 cm
F
C
10.9 cm
10.5 cm
B
D
12.2 cm 13.5 cm
E
Basin boundary
Polygonal areas
Fig. P2.25 Thiessen polygons
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 55
PRECIPITATION 55
Basin boundary
Isohyetals
7.3 cm
7.1 cm
9.6 cm
7.6 cm
8.9
cm
10
cm
V
IV
III
II
III
VI
5.5 cm
6
c
m
6
c
m
8
c
m
8.9 cm
8
c
m
6
c
m
4
c
m
5.6 cm
7.2 cm
I
5.2 cm 3.6 cm
4
c
m
6
c
m
-Rain gauge
stations
5.1 cm
Fig. P2.26 Isohyetal map
9 About 20 years of rainfall records (from both recording and non-recording rain-gauge stations)
are available. Exemplify with neat diagrams, giving typical formulae, how you correlate
(i) intensity and duration of storms
(ii) intensity, duration and frequency of stoms
10 The annual rainfall at a place for a period of 30 years is given below. Draw the rainfall frequency
curve and determine
(a) rainfalls of 5-yr, 10-yr and 20-yr recurrence interval
(b) the rainfall of probability 0.75
(c) the probability of occurence of rainfall 35 cm
Year
Rainfall
Year
Rainfall
(cm) (cm)
1951 31.6 1966 36.2
1952 30.1 1967 33.6
1953 29.8 1968 30.2
1954 39.9 1969 35.5
1955 37.8 1970 36.3
1956 31.3 1971 36.4
1957 30.7 1972 30.7
1958 38.0 1973 33.4
1959 35.7 1974 40.4
1960 32.9 1975 35.4
1961 30.3 1976 33.7
1962 41.0 1977 30.1
1963 33.5 1978 31.7
1964 34.0 1979 33.4
1965 33.3 1980 30.2
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 56
56 HYDROLOGY
11. The values of annual precipitation (cm/year) at a rain-gauge station in chronological sequence
from 1966 to 1977 are given below : Estimate the maximum and minimum values of precipita-
tion which has a recurrence interval of 5 years.
36.5 29.0 56.2 82.0 27.8 23.4
71.2 48.3 31.4 18.1 29.0 65.6
Hint for P
max
arrange Ps in the descending order when m is the no. of times P is equalled or
exceeded; for P
min
arrange Ps in the ascending order when m is the no. of times equal to or less
than P; use any of the three methods; from the graph, find P
max

or min
for T
r
= 5yr.
12 Annual precipitation at rain-gauge station X and the average annual precipitation at 20 sur-
rounding rain-gauge stations are given below. Examine the consistency of data at station X.
Indicate at what year a change in regime has occurred and how you are going to make the
necessary adjustments.
Year
Annual Ave. ann.
Year
Annual Ave. ann.
rainfall rainfall of rainfall at rainfall of
at stn. X 20 stns. stn. X 20 stns.
(cm) (cm) (cm) (cm)
1962 30.5 22.8 1972 28.2 33.3
1963 38.9 35.0 1973 17.3 23.4
1964 43.7 30.2 1974 22.3 36.0
1965 32.2 27.4 1975 28.4 31.2
1966 27.4 25.2 1976 24.1 23.1
1967 32.0 28.2 1977 26.9 23.4
1968 49.3 36.1 1978 20.6 23.1
1969 28.4 28.4 1979 29.5 33.2
1970 24.6 25.1 1980 28.4 26.4
1971 21.8 23.6
13 Define water equivalent of snow and explain how you estimate the snow melt?
14 Discuss the analysis of rainfall data with respect to time, space, frequency and intensity.
15 Explain areal and temporal distribution pattern of a typical storm over a catchment.
16 What is rain-gauge density? How does it affect the accuracy of rainfall measurements?
17 (a) What is meant by frequency of rainfall and recurrence interval?
(b) A rainfall of certain high intensity is expected to occur once in 20 years. What is its chance of
occurrence in any year ? What is the probability that it may occur in the next 12 years, and it
may not occur in the next 8 years. (5%, 46%, 66.4%)
18 Distinguish between snow, hail and rain. Explain the melting process of snow and the method of
measuring snow fall depth.
19 Estimate the intensity of a storm; which lasted for 60 min; constants in Talbots formula: a = 260,
b = 15, apply. (3.47 cm/hr)
20 The following are the modified data for a typical design storm of the Tapti river Basin in western
India. Develop a formula for the intensity duration relationship.
Time (hr): 1 2 3 6 12 24 48
Accumulated
rainfall (mm): 25 42 58 92 143 221 341
i
t
=
L
N
M
O
Q
P
25
0 4 .
mm/hr
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 57
PRECIPITATION 57
21 Using rational method, rainfall intensity-duration curves and the data given in Fig. P 2.27 com-
pute the diameter of the outfall sewer. The length of lines, drainage areas, and inlet times are
marked in Fig. P 2.27 (a). Assume:
(i) Run-off coefficient for the entire area = 0.30
(ii) Velocity of flow in sewers flowing full = 0.75 m/sec
(iii) 5-year average frequency curve may be used, Fig. P 2.27 (b),
(iv) Hydraulic elements for circular pipes flowing full are given in Table 2.2.
Table 2.2 Hydraulic elements for a circular pipe flowing full
Discharge Diameter Slope of Pipe Velocity
(Ips) (mm) (m/m) (m/sec)
400 450 0.025 2.7
600 525 0.020 2.8
690 1050 0.00055 0.75
1500 1350 0.001 1.55
2000 1450 0.001 1.20
[690 lps, 0.75 m/s, 1 m laid at 1 in 1800]
A = 0.016 km
Inlet time = 5 min
2
1
Most remote
point
2
Manhole 1
120 m
sewer
Manhole 2
A = 0.032
km
Inlet time
= 5 min
2
3
A = 0.024 km
Inlet time = 8 min
2
180 m
sewer
Manhole 3
Discharge
(a) Watershed system
25-year ave. frequency
10-year ave. frequency
5-year ave. frequency
0 5 10 20 30 40 50 60 70 80 90 100 110 120
200
175
150
125
100
75
50
25
0
Duration of rainfall, min
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
,
m
m
/
h
r
(b) Rainfall intensity-duration curves for
computation of storm water runoff
Fig. P2.27 Storm water drainage project
22 Explain step by step the procedure you would adopt to prepare the depth area-duration curves
for a particular storm, for a basin having a number of rain-gauges, most of which are recording.
23 The isohyets for a 2-day storm on a basin of 1038.3 km
2
are shown in Fig. P 2.28 and the area
between the isohyets as planimetered are given below. Draw the depth-area-duration curve for
the basin.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 58
58 HYDROLOGY
Zone Area (km
2
)
I 63.4
II 278.0
III 389.0
IV 220.0
V 55.2
VI 32.7
Total 1038.3
VI
III
I
II
III
IV
V
8.5 cm
13.5 cm
12.1 cm
1
0
c
m
1
0
c
m
1
5
c
m
17.1
cm
2
0
c
m
14.1
cm
Basin boundary
1
5
c
m
1
0
c
m
5
c
m
4.2
cm
13.2 cm
8.5
cm
4.2 cm
5
c
m
1
0
c
m
Fig. P2.28 Isohyetal map
24 Write short notes on:
(a) Isohyet (indicate the annual isohyet of your place)
(b) A.A.R. (give the a.a.r. of your place)
(c) Orographic precipitation (give example)
(d) Depth-area-duration curve
(e) Double-mass curve
(f) Cold and warm fronts
(g) Occlusion
(h) Cyclones and anticyclones
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD2-2.PM5 59
PRECIPITATION 59
(i) PMP
(j) Arid, semi-arid and humid regions
(k) Rain-gauge density and its effect on the accuracy of rainfall data
25 Severe Storms during 30 years over a basin gave the following maximum depths of precipitation:
Duration (min): 5 10 15 30 60 90 120
Max. pptn. (mm): 9 12 14 17 22 25 30
Develop a formula for the intensity-duration relationship. i
t
=
L
N
M
O
Q
P
285
0 62 .
, mm/ hr .
26 The mass curve of precipitation resulted from the storm of 14 August 1983 gave the following
results:
Time hr: 22.00 22.05 22.10 22.15 22.20 22.25 22.30 22.35 22.40 22.45 22.50
Depth mm: 0 10.2 20.8 33.0 47.2 55.8 64.0 77.6 78.8 85.4 91.4
For the storm construct a hyetograph and draw the maximum-intensity-duration curve.
(IES1984)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
The hydrologic equation states that
RainfallLosses = Runoff ...(3.1)
In the previous chapter we studied precipitation and its measurement. The various
water losses that occur in nature are enumerated below. If these losses are deducted from the
rainfall, the surface runoff can be obtained.
3.1 WATER LOSSES
(i) Interception loss-due to surface vegetation, i.e., held by plant leaves.
(ii) Evaporation:
(a) from water surface, i.e., reservoirs, lakes, ponds, river channels, etc.
(b) from soil surface, appreciably when the ground water table is very near the soil
surface.
(iii) Transpirationfrom plant leaves.
(iv) Evapotranspiration for consumptive usefrom irrigated or cropped land.
(v) Infiltrationinto the soil at the ground surface.
(vi) Watershed leakageground water movement from one basin to another or into the
sea.
The various water losses are discussed below:
Interception lossThe precipitation intercepted by foliage (plant leaves, forests) and
buildings and returned to atmosphere (by evaporation from plant leaves) without reaching the
ground surface is called interception loss. Interception loss is high in the beginning of storms
and gradually decreases; the loss is of the order of 0.5 to 2 mm per shower and it is greater in
the case of light showers than when rain is continuous. Fig. 3.1 shows the Hortons mean curve
of interception loss for different showers.
Effective rain = Rainfall Interception loss
3.2 EVAPORATION
Evaporation from free water surfaces and soil are of great importance in hydro-meterological
studies.
Evaporation from water surfaces (Lake evaporation)
The factors affecting evaporation are air and water temperature, relative humidity,
wind velocity, surface area (exposed), barometric pressure and salinity of the water, the last
Chapter 3
60
WATER LOSSES
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 61
WATER LOSSES 61
two having a minor effect. The rate of evaporation is a function of the differences in vapour
pressure at the water surface and in the atmosphere, and the Daltons law of evaporation is
given by
E = K (e
w
e
a
) ...(3.2)
0 2.5 5 7.5 10 12.5 15 17.5 20
100
90
80
70
60
50
40
30
20
10
0
Storm precipitation (mm)
I
n
t
e
r
c
e
p
t
i
o
n
l
o
s
s
(
%
)
Hortons mean curve for
interception loss
Fig. 3.1 Interception loss (Horton)
where E = daily evaporation
e
w
= saturated vapour pressure at the temperature of water
e
a
= vapour pressure of the air (about 2 m above)
K = a constant.
i.e., the Daltons law states that the evaporation is proportional to the difference in vapour
pressures e
w
and e
a
. A more general form of the Eq. (3.2) is given by
E = K (e
w
e
a
) (a + bV) ...(3.3)
where K, a, b = constants and V = wind velocity.
Higher the temperature and wind velocity, greater is the evaporation, while greater the
humidity and dissolved salts, smaller is the evaporation. The annual evaporation from irriga-
tion tanks in south India is of the order of 160 to 180 cm, the highest evaporation being in the
summer months of April and May. The monthly evaporation from Krishnarajasagara reser-
voir (near Mysore, south India) is given below:
Month
Evaporation Month Evaporation
(cm) (cm)
January 11.9 July 11.9
February 10.2 August 11.9
March 12.7 September 11.9
April 17.8 October 15.1
May 20.3 November 11.9
June 15.1 December 11.9
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 62
62 HYDROLOGY
Methods of Estimating Lake Evaporation
Evaporation from water surfaces can be determined from the following methods :
(i) The storage equation
P + I O
g
= E + O S ...(3.4)
where P = Precipitation
I = surface inflow
O
g
= subsurface inflow or outflow
E = evaporation
O = surface outflow
S = change in surface water storage
(ii) Auxiliary pans like land pans, floating pans, colarado sunken pans, etc.
(iii) Evaporation formula like that of Daltons law
(iv) Humidity and wind velocity gradients
(v) The energy budgetthis method involves too many hydrometeorological factors
(variables) with too much sophisticated instrumentation and hence it is a specialist
approach
(vi) The water budgetsimilar to (i)
(vii) Combination of aerodynamic and energy balance equationsPenmans equation (in-
volves too many variables)
3.3 EVAPORATION PANS
(i) Floating pans (made of GI) of 90 cm square and 45 cm deep are mounted on a raft
floating in water. The volume of water lost due to evaporation in the pan is determined by
knowing the volume of water required to bring the level of water up to the original mark daily
and after making allowance for rainfall, if there has been any.
(ii) Land pan. Evaporation pans are installed in the vicinity of the reservoir or lake to
determine the lake evaporation. The IMD Land pan shown in Fig. 3.2 is 122 cm diameter and
2.5 cm
GL
0.9-mm thick
copper sheet Water 19 cm
2 cm
122 cm dia.
Point gauge
stilling well, 10.2 cm dia
25.5 cm, land pan
10 cm, wooden cribs
Fig. 3.2 IMD land pan
25.5 cm deep, made of unpainted GI; and set on wood grillage 10 cm above ground to permit
circulation of air under the pan. The pan has a stilling well, vernier point gauge, a thermometer
with clip and may be covered with a wire screen. The amount of water lost by evaporation from
the pan can be directly measured by the point gauge. Readings are taken twice daily at 08.30
and 17.30 hours I.S.T. The air temperature is determined by reading a dry bulb thermometer
kept in the Stevensons screen erected in the same enclosure of the pan. A totalising anemometer
is normally mounted at the level of the instrument to provide the wind speed information
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 63
WATER LOSSES 63
required. Allowance has to be made for rainfall, if there has been any. Water is added to the
pan from a graduated cylinder to bring the water level to the original mark, i.e., 5 cm below the
top of the pan. Experiments have shown that the unscreened pan evaporation is 1.144 times
that of the screened one.
(iii) Colarado sunken pan. This is 92 cm square and 42-92 cm deep and is sunk in the
ground such that only 5-15 cm depth projects above the ground surface and thus the water
level is maintained almost at the ground level. The evaporation is measured by a point gauge.
Pan coefficientEvaporation pan data cannot be applied to free water surfaces di-
rectly but must be adjusted for the differences in physical and climatological factors. For ex-
ample, a lake is larger and deeper and may be exposed to different wind speed, as compared to
a pan. The small volume of water in the metallic pan is greatly affected by temperature fluc-
tuations in the air or by solar raditions in contrast with large bodies of water (in the reservoir)
with little temperature fluctuations. Thus the pan evaporation data have to be corrected to
obtain the actual evaporation from water surfaces of lakes and reservoirs, i.e., by multiplying
by a coefficient called pan coefficient and is defined as
Pan coefficient =
Lake evaporation
Pan evaporation
...(3.5)
and the experimental values for pan coefficients range from 0.67 to 0.82 with an average of 0.7.
Example 3.1 The following are the monthly pan evaporation data (Jan.-Dec.) at
Krishnarajasagara in a certain year in cm.
16.7, 14.3, 17.8, 25.0, 28.6, 21.4
16.7, 16.7, 16.7, 21.4, 16.7, 16.7
The water spread area in a lake nearby in the beginning of January in that year was
2.80 km
2
and at the end of December it was measured as 2.55 km
2
. Calculate the loss of water
due to evaporation in that year. Assume a pan coefficient of 0.7.
Solution Mean water spread area of lake
A
ave
=
1
3
(A
1
+ A
2
+ A A
1 2
), cone formula
=
1
3
(2.80 + 2.55 + 2 80 2 55 . . )
= 2.673 km
2
Annual loss of water due to evaporation (adding up the monthly values)
= 228.7 cm
Annual volume of water lost due to evaporation
= (2.673 10
6
)
2287
100
.
0.7
= 4.29 10
6
m
3
or 4.29 Mm
3
Example 3.1 (a) Compute the daily evaporation from a Class A pan if the amounts of water
added to bring the level to the fixed point are as follows:
Day: 1 2 3 4 5 6 7
Rainfall (mm): 14 6 12 8 0 5 6
Water 5 3 0 0 7 4 3
added (mm): (removed)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 64
64 HYDROLOGY
What is the evaporation loss of water in this week from a lake (surface area = 640 ha) in
the vicinity, assuming a pan coefficient of 0.75?
Solution Pan evaporation, E
p
, mm = Rainfall
+

water added
or
water removed
Day: 1 2 3 4 5 6 7
E
p
: 14 5 6 + 3 12 8 7 5 + 4 6 + 3
(mm): = 9 = 9 = 9 = 9
Pan evaporation in the week =
1
7

E
p
= 63 mm
Pan coefficient 0.75 =
E
E
L
p
Lake evaporation during the week E
L
= 63 0.75 = 47.25 mm
Water lost from the lake = A . E
L
= 640
47 25
1000
.
= 30.24 ha.m ~

0.3 Mm
3
Example 3.1 (b) The total observed runoff volume during a storm of 6-hr duration with a
uniform intensity of 15 mm/hr is 21.6 Mm
3
. If the area of the basin is 300 km
2
, find the average
infiltration rate and the runoff coefficient for the basin.
Solution (i) Infiltration loss F
p
= Rainfall (P) Runoff (R)
= 15 6
21.6 10 m
300 10 m
6 3
6 2

1000
= 90 72 = 18 mm
f
ave
=
F
t
p
=
18 mm
6 hr
= 3 mm/hr
(ii) Yield = C A P
21.6 10
6
m
3
= C(300 10
6
m
2
)
90
1000
C = 0.8
Piche Evaporimeter
It is usually kept suspended in a Stevenson screen. It consists of a disc of filter paper kept
constantly saturated with water from a graduated glass tube Fig. 3.3. The loss of water from
the tube over a known period gives the average rate of evaporation. Though it is a simple
instrument, the readings obtained are often more erratic than those from standard pans.
Measures to Reduce Lake Evaporation
The following are some of the recommended measures to reduce evaporation from water sur-
faces :
(i) Storage reservoirs of more depth and less surface area, i.e., by choosing a cross
section of the reservoir like a deep gorge Fig. 3.4 ; while the surface water is exposed to tem-
perature gradients the deeper waters are cool; from this standpoint a large reservoir is prefer-
able to a number of small reservoirs (while it is the reverse from the point of flood control).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 65
WATER LOSSES 65
0
1
3
4
5
2
Suspension in
Stevenson screen
Water level
Graduated
glass tube
with water
Porous cup
saturated
with water
Water
evaporates
here
Fig. 3.3. Piche evaporimeter
Minimum surface area
to reduce evaporation
Cool deep
water
Fig. 3.4 Reservoir in a deep gorge
(ii) By growing tall trees like Causerina on the windward side of the reservoirs to act as
wind breakers.
(iii) By spraying certain chemicals or fatty acids and formation of films. By spreading a
manomolecular layer of acetyl alcohol (hexadecanol) C
16
H
33
OH over the reservoir surface (from
boats)a film is formed on the surface which is only 0.015 micron (approx.) in thickness. It is
a polar compound and it has great affinity for water on one side (hydrophylic) and repels water
on the other side (hydrophobic). The film will only allow precipitation from the top into it but
will not allow water molecules to escape from it. This method is readly effective when the wind
velocities are less. If the wind velocity is more, it will sweep the film off the water surface and
deposit it on the bank. However the film is pervious to O
2
and CO
2
. About 2.2 kg (22 N) of
acetyl alcohol is required to cover an area of 1 ha of reservoir surface. It is best suited for small
and medium size reservoirs.
(iv) By allowing flow of water, temperature is reduced and evaporation is reduced; i.e.,
by designing the outlet works so that the warmer surface water can be released.
(v) By removing the water loving weeds and plants like Phreatophytes from the periph-
ery of the reservoir.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 66
66 HYDROLOGY
(vi) By straightening the stream-channels the exposed area of the water surface (along
the length) is reduced and hence evaporation is reduced.
(vii) By providing mechanical coverings like thin polythene sheets to small agricultural
ponds and lakes.
(viii) By developing undergound reservoirs, since the evaporation from a ground water
table is very much less than the evaporation from a water surface.
(ix) If the reservoir is surrounded by huge trees and forest, the evaporation loss will be
less due to cooller environment.
3.4 SOIL EVAPORATION
The evaporation from a wet soil surface immediately after rain or escape of water molecules
with more resistance when the water table lies within a metre from the ground is called soil
evaporation. This, expressed as a percentage of evaporation from free water surface is called
evaporation opportunity.
Evaporation opportunity =
Actual evaporation fromthe land
(soil) at a given time
Evaporation froman equivalent
water surface
100 ...(3.6)
Soil evaporation will continue at a high rate for some time after the cessation of rainfall,
then decreases as the ground surface starts drying, until a constant rate is reached which is
dependent on the depth of the water table and nature of the soil in addition to meteorological
conditions.
Measurement of soil evaporation can be done with tanks (lysimeters) filled with earth
and with the surface almost flush with the ground Fig. 3.5. To measure the evaporation from
a soil whose surface is within the capillary fringe, tanks equipped to maintain the water table
at any desired elevation may be used. The soil evaporation is determined by weighing the
tanks at stated intervals and knowing the amount of water that was added in the interim.
Filled with soil
Level of GWT
Tank 1 m 1 m 1.5 m
dimensions

GS
Soil surface inside
Evaporation from
soil surface
Fig. 3.5 Lysimeter for soil evaporation
3.5 UNSATURATED FLOW
Soil moisture in the unsaturated zone moves under the influence of the gravitational force and
the force due to the difference in capillary potential. The capillary flow is given by Darcys law.
Q = K
u
iA ...(3.7)
i =
Z
l
h
l
+
...(3.7 a)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 67
WATER LOSSES 67
where Q = capillary flow
K
u
= coefficient of unsaturated permeability
i = sum of the gradients of capillary potential and gravitational force
A = area of cross section of capillary flow
Z = difference in elevation of the two points A and B (if the flow is from A to B).
h = difference in capillary potential of the two points A and B
l = length of travel
when the capillary potential becomes greater than the gravitational potential there is upward
movement of soil moisture resulting in loss of water due to soil evaporation. When the flow is
upward, the gravitational component of i must be subtracted from the capillary potential
component. For horizontal flow the gravitational component is zero. For downward flow the
two motivating forces act in the same direction. The coefficient of unsaturated permeability
increases as the soil moisture increases.
3.6 TRANSPIRATION
Tanspiration is the process by which the water vapour escapes from the living plant leaves
and enters the atmosphere. Various methods are devised by botanists for the measurement of
transpiration and one of the widely used methods is by phytometer. It consists of a closed
water tight tank with sufficient soil for plant growth with only the plant exposed; water is
applied artificially till the plant growth is complete. The equipment is weighed in the begin-
ning (W
1
) and at the end of the experiment (W
2
). Water applied during the growth (w) is meas-
ured and the water consumed by transpiration (W
t
) is obtained as
W
t
= (W
1
+ w) W
2
...(3.8)
The experimental values (from the protected growth of the plant in the laboratory) have
to be multiplied by a coefficient to obtain the possible field results.
Transpiration ratio is the ratio of the weight of water absorbed (through the root sys-
tem), conveyed through and transpired from a plant during the growing season to the weight
of the dry matter produced exclusive of roots.
Transpiration ratio =
weight of water transpired
weight of dry matter produced
...(3.9)
For the weight of dry matter produced, sometimes, the useful crop such as grains of
wheat, gram, etc. are weighed. The values of transpiration ratio for different crops vary from
300 to 800 and for rice it varies from 600 to 800 the average being 700.
Evaporation losses are high in arid regions where water is impounded while transpira-
tion is the major water loss in humid regions.
3.7 EVAPOTRANSPIRATION
Evapotranspiration (E
t
) or consumptive use (U) is the total water lost from a cropped (or irri-
gated) land due to evaporation from the soil and transpiration by the plants or used by the
plants in building up of plant tissue. Potential evapotranspiration (E
pt
) is the evapotranspiration
from the short green vegetation when the roots are supplied with unlimited water covering
the soil. It is usually expressed as a depth (cm, mm) over the area.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 68
68 HYDROLOGY
Estimation of Evapotranspiration
The following are some of the methods of estimating evapotranspiration:
(i) Tanks and lysimeter experiments
(ii) Field experimental plots
(iii) Installation of sunken (colarado) tanks
(iv) Evapotranspiration equations as developed by Lowry-Johnson, Penman,
Thornthwaite, Blaney-Criddle, etc.
(v) Evaporation index method, i.e., from pan evaporation data as developed by
Hargreaves and Christiansen.
For detailed discussions of the above methods reference may be made to the authors
companion volume on Ground Water published by Wiley Eastern Limited, New Delhi, 1981.
However, two well known methods are discussed here.
(i) Blaney-Criddle method. This method is used throughout the world for the consump-
tive use determinations and is given by :
U =
ktp
100
in FPS units ...(3.10)
and U =
kp t ( . . ) 4 6 813
100
+
in metric units ...(3.10 a)
U = kf = K f = KF ...(3.10 b)
f =
tp
100
in FPS units ...(3.10 c)
f =
p t ( . . ) 4 6 813
100
+
in metric units ...(3.10 d)
where U = seasonal consumptive use (inches in FPS units and cm in metric units)
t = mean monthly temperature (F in FPS units and C in metric units)
p = monthly percentage of hours of bright sunshine (of the year)
k = monthly consumptive use coefficient determined from experimental data
f = monthly consumptive use factor
K, F = seasonal values of consumptive use coefficient and factor, respectively
refers for the summation for all the months of the growing season.
Example 3.2 Determine the evapotranspiration and irrigation requirement for wheat, if the
water application efficiency is 65% and the consumptive use coefficient for the growing season
is 0.8 from the following data :
Month Mean monthly Monthly percentage Effective rainfall
temp (C) of sunshine (hours) (cm)
November 18 7.20 2.6
December 15 7.15 2.8
January 13.5 7.30 3.5
February 14.5 7.10 2.0
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 69
WATER LOSSES 69
Solution
Month Mean monthly Monthly % of Effective rainfall Monthly con-
temp. (C) sunshine (hours) (cm) sumptive use
t p P
e
factor
f =
p(4.6t 81.3)
100
+
Nov. 18 7.20 2.6 11.82
Dec. 15 7.15 2.8 10.74
Jan. 13.5 7.30 3.5 10.48
Feb. 14.5 7.10 2.0 10.50
P
e
= 10.9 f = 43.54
Seasonal consumptive use, U = K f
= 0.8 43.54
= 34.83 cm
Field irrigation requirement,
F.I.R. =
U P
e
i

...(3.11)
where
i
= water application efficiency
F.I.R. = Field irrigation requirement
F.I.R. =
34 83 10 90
0 65
. .
.

= 36.9 cm
(ii) Evaporation Index method. Analysis of data on consumptive use indicate a high
degree of correlation between pan evaporation values and consumptive use. The relationship
between the evapotranspiration (E
t
) and pan evaporation (E
p
) is usually expressed as
E
t
= kE
p
...(3.12)
where k is a coefficient (i.e., E
t
/E
p
ratio) and is found to vary according to the stage of growth of
the crop. The values of k for different crops at 5% increments of the crop growing season are
presented by G.H. Hargreaves.
Example 3.3 Assuming a growing season of 4 months December-March for wheat, determine
the consumptive use of wheat in the month of January if the pan evaporation for the month is
9.5 cm. Take the consumptive use coefficient at 40%, stage growth of the crop as 0.52.
Solution E
t
= kE
p
The crop season is December to March i.e., 120 days. By middle of Jaunary the number
of days of growth is 47, i.e.,
47
120
= 0.40 or 40% stage growth of the crop has reached and k for
this stage is 0.52 and E
p
for the month of January is 9.5 cm.
E
t
= 0.52 9.5 = 4.94 cm
The daily consumptive use for the month of January
=
4 94 10
31
.
= 1.6 mm/day
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 70
70 HYDROLOGY
Factors Affecting Evapotranspiration
From the above equations it can be seen that the following factors affect the evapotranspiration:
(i) Climatological factors like percentage sunshine hours, wind speed, mean monthly
temperature and humidity.
(ii) Crop factors like the type of crop and the percentage growing season.
(iii) The moisture level in the soil.
3.8 HYDROMETEOROLOGY
Hydrometeorology is the science which deals with the movement of water and water vapour in
the atmosphere. A typical hydro-meteorological set-up at Regional Agricultural Research Sta-
tion, Aduturai, Thanjavur District, Tamil Nadu is given below:
(i) Wind vane with cardinal points NSE & W mounted on a masonry pillar.
(ii) Cup Counter anemometer (three cups) mounted on a masonry pillar.
(iii) Rain gauge with inner can fixed on a masonry platform. Top of rain gauge was 30
cm above ground level.
(iv) Sunshine recorder mounted on masonry pillar. The number of sunshine hours per
day are recorded on a strip of cardboard, a spherical magnifying glass burning a hole in the
middle of the cardboard strip whenever the sun is out.
(v) Stevensons Screen. Double louvred, holding maximum and minimum thermometers
and Dry and Wet Bulb thermometers; and PICHE Evaporimeter kept suspended.
(vi) Assmann Hygrometer with hand driven aspiration fan and insulated thermometers;
wooden framework erected on the ground for keeping the hygrometer at different heights.
(vii) Dew gauge. Stand with four exposure brackets (two on either side) with chocolate
coloured blocks of wood and book of dew scale standards.
(viii) Soil Temperature thermometers with stems bent3 numbers embedded at 5, 15
and 30 cm in the soil.
(ix) IMD Land pan with stilling well and Vernier Hook gauge placed on a wooden frame
work 10 cm in depth. The pan is covered with a wire screen (chicken wire).
All the measurements are taken twice a day at 07-12 and 14-12 hours IST in the station.
3.9 INFILTRATION
Water entering the soil at the ground surface is called infiltration. It replenishes the soil mois-
ture deficiency and the excess moves downward by the force of gravity called deep seepage or
percolation and builds up the ground water table. The maximum rate at which the soil in any
given condition is capable of absorbing water is called its infiltration capacity (f
p
). Infiltration
(f) often begins at a high rate (20 to 25 cm/hr) and decreases to a fairly steady state rate (f
c
) as
the rain continues, called the ultimate f
p
(= 1.25 to 2.0 cm/hr) (Fig. 3.6). The infiltration rate (f)
at any time t is given by Hortons equation.
f = f
c
+ (f
o
f
c
) e
kt
...(3.13)
k =
f f
F
c
c
0

...(3.13 a)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 71
WATER LOSSES 71
where f
0
= initial rate of infiltration capacity
f
c
= final constant rate of infiltration at saturation
k = a constant depending primarily upon soil and vegetation
e = base of the Napierian logarithm
F
c
= shaded area in Fig. 3.6
t = time from beginning of the storm
0 2 4 6 8 10 12 14 16 18 20 22
Time t (min)
f = final constant rate
c
f Shaded area = F
c
F
c
8
7
6
5
4
3
2
1
0
I
n
f
i
l
t
r
a
t
i
o
n
r
a
t
e
(
c
m
/
h
r
)
f = initial infiltration rate
o
Infiltration curve (Horton):
f = f + (f f ) e , k =
c o c
kt f f
o c
F
c
t
Fig. 3.6 Infiltration Curve (Horton)
The infiltration takes place at capacity rates only when the intensity of rainfall equals
or exceeds f
p
; i.e., f = f
p
when i f
p
; but when i < f
p
, f < f
p
and the actual infiltration rates are
approximately equal to the rainfall rates.
The infiltration depends upon the intensity and duration of rainfall, weather (tempera-
ture), soil characteristics, vegetal cover, land use, initial soil moisture content (initial wet-
ness), entrapped air and depth of the ground water table. The vegetal cover provides protec-
tion against rain drop impact and helps to increase infiltration.
Methods of Determining Infiltration
The methods of determining infiltration are:
(i) Infiltrometers
(ii) Observation in pits and ponds
(iii) Placing a catch basin below a laboratory sample
(iv) Artificial rain simulators
(v) Hydrograph analysis
(i) Double-ring infiltrometer. A double ring infiltrometer is shown in Fig. 3.7. The two
rings (22.5 to 90 cm diameter) are driven into the ground by a driving plate and hammer, to
penetrate into the soil uniformly without tilt or undue disturbance of the soil surface to a
depth of 15 cm. After driving is over, any disturbed soil adjacent to the sides tamped with a
metal tamper. Point gauges are fixed in the centre of the rings and in the annular space be-
tween the two rings. Water is poured into the rings to maintain the desired depth (2.5 to 15 cm
with a minimum of 5 mm) and the water added to maintain the original constant depth at
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 72
72 HYDROLOGY
regular time intervals (after the commencement of the experiment) of 5, 10, 15, 20, 30, 40, 60
min, etc. up to a period of atleast 6 hours is noted and the results are plotted as infiltration
rate in cm/hr versus time in minutes as shown in Fig. 3.8. The purpose of the outer tube is to
eliminate to some extent the edge effect of the surrounding drier soil and to prevent the water
within the inner space from spreading over a larger area after penetrating below the bottom of
the ring.
depth maintained
constant, say 8 cm
15 cm driven
into ground
GS
25 cm
30 cm dia.
45 cm dia.
Water
Soil
Infiltrating water
a. Section
Const.
water depth
Const.
water
depth
Outer ring,
45 cm dia.
Inner ring,
30 cm dia.
b. Plan
Fig. 3.7 Double ring infiltrometer
35
30
25
20
15
10
5
0
0 20 40 60 80 100 120 140 160 180 200 220 240
Time (min)
Infiltration
curve (initial)
Wet soil
I
n
f
i
l
t
r
a
t
i
o
n
r
a
t
e
(
c
m
/
h
r
)
Fig. 3.8 Typical infiltration curve
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 73
WATER LOSSES 73
Tube infiltrometer. This consists of a single tube about 22.5 cm diameter and 45 to 60 cm
long which is driven into the ground atleast to a depth up to which the water percolates during
the experiment and thus no lateral spreading of water can occur (Fig. 3.9). The water added
into the tube at regular time intervals to maintain a constant depth is noted from which the
infiltration curve can be drawn.
25 cm dia.
15 cm
GS
Water
Soil
Const. depth of water
8 cm
Tube
55 cm
Infiltrating water
Fig. 3.9 Tube infiltrometer
Example 3.4 For a given basin, the following are the infiltration capacity rates at various time
intervals after the beginning of the storm. Make a plot of the f-curve and establish an equation
of the form developed by Horton. Also determine the total rain and the excess rain (runoff).
Time Precipitation rate Infiltration capacity
(min) (cm/hr) (cm/hr)
1 5.0 3.9
2 5.0 3.4
3 5.0 3.1
4 5.0 2.7
5 5.0 2.5
6 7.5 2.3
8 7.5 2.0
10 7.5 1.8
12 7.5 1.54
14 7.5 1.43
16 2.5 1.36
18 2.5 1.31
20 2.5 1.28
22 2.5 1.25
24 2.5 1.23
26 2.5 1.22
28 2.5 1.20
30 2.5 1.20
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 74
74 HYDROLOGY
Solution The precipitation and infiltration rates versus time are plotted as shown in Fig. 3.10.
In the Hortons equation, the Hortons constant
k =
f f
F
c
c
0

0 1 2 4 6 8 t 10 12 14 16 18 20 22 24 26 28 30
Time t (min)
f = 1.2 cm/hr
c
F
c
10
9
8
7
6
5
4
3
2
1
0
Infiltration loss (under f-curve)
f
I
n
t
e
n
s
i
t
y
o
f
r
a
i
n
f
a
l
l
i
(
c
m
/
h
r
)
I
n
f
i
l
t
r
a
t
i
o
n
r
a
t
e
f
(
c
m
/
h
r
)
f = 4.5 cm/hr Runoff, P
o net
f-curve: f = 1.2 +
3.3
e
12t
Projected
Rainfall i = 7.5 cm/hr
Scale : f sq. unit = 2 min = cm
1 cm
60 min
1
30
Rainfall P = 68.75 sq. units
Area under
f-curve F = 26.5 sq. units
p
Runoff P = P F
net p
= 68.75 26.5
= 42.25 sq. units
Shaded
area F
c
= 8.25 sq. units
i = 2.5 cm/hr
i =5cm/hr
t
f
f
Fig. 3.10 Infiltration loss and net rain (Example 3.4)
From Fig. 3.10, shaded area
F
c
= 4.25 sq. units
= 8.25
1cm
60 min
2 min
F
H
G
I
K
J = 8.25
1
30
= 0.275 cm
k =
(4.5 1.2) cm/hr
0.275 cm

= 12 hr
1
The Hortons equation is
f = f
c
+ (f
0
f
c
)e
kt
= 1.2 + (4.5 1.2)e
12t
f = 1.2 +
3.3
e
12t
is the equation for the infiltration capacity curve (f-curve) for the basin, where f is in cm/hr and
t in hr.
For example, for t = 10 min =
10
60
1
6
=
hr
f = 1.2 +
3 3
12 1/ 6
.
e

= 1.7 cm/hr, which is very near compared
to the observed value of 1.8 cm/hr.
Total rain P = 68.75 sq. units = 68.75
1
30
= 2.29 cm
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 75
WATER LOSSES 75
Excess rain P
net
= P F
p
= 68.75 26.5 = 42.25 sq. units
= 42.25
1
30
= 1.41 cm
Total infiltration F
p
= 26.5
1
30
= 0.88 cm
The total infiltration loss F
p
can also be determined by intergrating the Hortons equa-
tion for the duration of the storm.
F
p
=
0 0
30 60
12
12
3 3
t
t
fdt
e
dt
z z
= +
F
H
G
I
K
J
/
.
.
= 1.2t +
3 3
12
12
0
30 60
.
/

O
Q
P
e
t
= 12
30
60
3 3
12
0
3 3
12
12 30 60 0
.
. .
/

L
N
M
O
Q
P

L
N
M
O
Q
P
e e
= 0.6 +
33
12
.
1
1
6

F
H
G
I
K
J
e
= 0.6 +
33
12
.

1
1
408

F
H
G
I
K
J
= 0.88 cm
P
net
= P F
p
= 2.29 0.88
= 1.41 cm
which compares with the value obtained earlier.
Ave. infiltration loss f
ave
=
F
t
p
=
0.88 cm
1/2 hr
= 1.76 cm/hr
To determine the Hortons constant by drawing a semi-log plot of t vs. (f f
c
):
The Hortons equation is
f = f
c
+ (f
0
f
c
)e
kt
log (f f
c
) = log (f
0
f
c
) kt log e
Solving for t,
t =
log ( )
log
log ( )
log
f f
k e
f f
k e
c c 0


which is in the form of a straight line y = mx + c in which y = t, x = log (f f
c
), m =
1
k e log
.
Hence, from a plot of t vs. (f f
c
) on a semi-log paper (t to linear scale), the constants in the
Hortons equation can be determined.
From the given data, f
c
= 1.2 cm/hr and the values of (f f
c
) for different time intervals
from the beginning are: 2.7, 2.2, 1.9, 1.5, 1.3, 1.1, 0.8, 0.6, 0.46, 0.32, 0.22, 0.16, 0.12, 0.05, 0.04,
0.02, 0.0 cm/hr, respectively ; (note: 3.9 1.2 = 2.7 cm/hr and like that for other readings).
These values are plotted against time on a semi-log paper as shown in Fig. 3.11.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-1.PM5 76
76 HYDROLOGY
From Fig. 3.11, m = 0.1933 =
1
k e log
log e = 0.434 k =
1
0 1933 0 434 . .
= 12 hr
1
36
32
28
24
20
16
12
8
4
0
0.01 .02 .03 .04 .06 .08 0.1 .2 .3 .4 .6 .8 1.0 2 3 4 5 6 8 10
Value of (f-f ) to log scale (cm/hr)
c
T
i
m
e
t
,
m
i
n
t
o
l
i
n
e
a
r
s
c
a
l
e
0.01 0.1 1 10
f = 1.2 +
3.3
e
12t
f in cm/hr
t in hr
Semi-log paper
Dy = 11.6 min
Dx = log = 1
1.0
0.1
Slope m = = 0.1933 =
11.6/60
1
1
k log e
\ k =
= 12 hr
1
1
0.19330.434
f f = 3.3
o c
t = o
Fig. 3.11 Semi-log plot for infiltration constants (Example 3.4)
Also from the graph, when t = 0,
f f
c
= 3.3 = f
0
f
c
, (since f = f
0
when t = 0)
f
0
= 3.3 + 1.2 = 4.5 cm/hr
Hence, the Hortons equation is of the form
f = 1.2 + (4.5 1.2)e
12t
or f = 1.2 +
3.3
e
12t
where f is in cm/hr and t in hr.
Total rain P = 5
5
60
7 5
10
60
2 5
15
60
+ + . .
= 2.29 cm
Infiltration loss F
p
= 0.88 cm
Excess rain (runoff), P
net
= P F
p
= 2.29 0.88
= 1.41 cm
which compares with the value obtained earlier.
(ii) Observation from infiltration pits and ponds. By noting the depression in the level
of water in the pits and ponds and deducting the loss due to evaporation, an idea about the
infiltration rates in such soils can be obtained.
(iii) By placing a catch basin called a lysimeter under a laboratory sample or at some
depth below the land surface, the infiltrating water can be measured and the infiltration rate
in the soil can be obtained.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 77
WATER LOSSES 77
(iv) Artificial rain simulators on a small area of land of 0.1 to 50 m
2
, water is applied by
artificial showers at a uniform rate. The resulting surface runoff is measured and the infiltra-
tion capacity of the soil is determined.
(v) Hydrograph analysis. By knowing accurately the varying intensities of rainfall dur-
ing a storm and the continuous record of the resulting runoff, the infiltration capacity can be
determined and is discussed in the next chapter.
Example 3.4 (a) For a small catchment, the infiltration rate at the beginning of rain was
observed to be 90 mm/hr and decreased exponentially to a constant rate of 8 mm/hr after
2
1
2
hr. The total infiltration during 2
1
2
hr was 50 mm. Develop the Hortons equation for the
infiltration rate at any time t < 2
1
2
hr.
Solution k =
f f
F
c
c
0

=
90 8
50 8 25

.
= 2.73 hr
1
Hortons eqn.: f = f
c
+ (f
0
f
c
)e
kt

= 8 + (90 8)e
2.73 t
or f = 8 + 82e
2.73 t
, f in mm/hr, t in hr.
Example 3.5 A 24-hour storm occurred over a catchment of 1.8 km
2
area and the total rainfall
observed was 10 cm. An infiltration capacity curve prepared had the initial infiltration capac-
ity of 1 cm/hr and attained a constant value of 0.3 cm/hr after 15 hours of rainfall with a
Hortons constant k = 5 hr
1
. An IMD pan installed in the catchment indicated a decrease of 0.6
cm in the water level (after allowing for rainfall) during 24 hours of its operation. Other losses
were found to be negligible. Determine the runoff from the catchment. Assume a pan coefficient
of 0.7.
Solution F
p
=
0
24
0
z
+

f f f e
c c
kt
( ) dt =
0
24
5
0 3 10 0 3
z
+

. ( . . ) e
t
dt
= 0.3t +
0 7
5
5
0
24
.

O
Q
P
e
t
= 0 3 24
0 7
5
0
0 7
5
5 24 0
.
. .

L
N
M
O
Q
P

L
N
M
O
Q
P
e e
= 7.2 +
07
5
1
1
120
.

F
H
G
I
K
J
e
= 7.34 cm
Runoff = P F
p
E = 10 7.34 (0.60 0.7)
= 2.24 cm
Volume of runoff from the catchment
=
224
100
.
(1.8 10
6
) = 40320 m
3
Example 3.5 (a) In a double ring infiltrometer test, a constant depth of 100 mm was restored
at every time interval the level dropped as given below:
Time (min) 0 5 10 15 25 45 60 75 90 110 130
Depth of water (mm) 100 83 87 90 85 78 85 85 85 80 80
(i) Establish the infiltration equation of the form developed by Horton.
(ii) Obtain the equation for cumulative infiltration of the form (a) F = at
n
(b) F = at
n
+ b.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 78
78 HYDROLOGY
Solution
Depth to water
Surface (mm)
Time t (min) Before After Depth of Infiltration Cumulative f
c
= 60 mm/hr
filling filling infiltration rate infiltration f f
c
mm/hr
d (mm) f =
d
t
60 F = d mm
(mm/hr)
0 100 0 f
0
0
5 83 100 17
17
5
60 = 204 17 144
10 87 100 13
13
10 5
60 = 156 30 96
15 90 100 10
10
15 10
60 = 120 40 60
25 85 100 15 90 55 30
45 78 100 22 66 77 6
60 85 100 15 60 = f
c
92 0
75 85 100 15 60 107 0
90 85 100 15 60 122 0
110 80 100 20 60 142 0
130 80 100 20 60 162 0
(i) (a) Plot on natural graph paper, t vs. f, Fig. 3.11(a)
Hortons equation f = f
c
+ (f
0
f
c
) e
kt
f
0
= 300 mm/hr, f
c
= 60 mm/hr
F
c
= shaded area
= 6 sq. units
50
60
min
min
10 min
= 50 mm
Hortons constant k =
f f
F
c
c
0

=
300 60
50

= 4.8 hr
1
f = 60 +
240
4 8
e
t .
where f is in mm/hr, t in hr.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 79
WATER LOSSES 79
(b) Plot on semi-log paper t vs. log (f f
c
), Fig. (3.11 b).
f = 60 mm/hr
c
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140
Time t (min)
t
hr
F
C
400
300
200
f
100
50
0
I
n
f
i
l
t
r
a
t
i
o
n
r
a
t
e
f
(
m
m
/
h
r
)
f = 300 mm/hr
o
Horton: f = 60 + , t in hr
240
e
4.8t
Natural graph paper
Fig. 3.11 (a) Hortons infiltration curve
50
40
30
20
10
0
1 1.5 2 3 4 6 8 10 20 30 50 70 100 200 300 600 1000
t = 0
f f = 240 = f f
c o c
Slope
m =
27.5 min/60 hr
Log mm/hr
100
10
=
1
k log e
\ k = 4.8 hr
1
1 Log-cycle
27.5
min
Semi-log paper
10 100 1
T
i
m
e
t
(
m
i
n
)
(f f ) (mm/hr)
c
Fig. 3.11 (b) Hortons infiltration constants (k, f
o
)
f = f
c
+ (f
0
f
c
)e
kt
log (f f
c
) = log (f
0
f
c
) kt log e
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 80
80 HYDROLOGY
t =
log ( )
log
log ( )
log
f f
k e
f f
k e
c c 0


i.e., of the form, y = c + mx
Slope m =
1
k e log
=
27 5 60
1
. /
k = 4.8 hr
1
at t = 0, f f
c
= 240 = f
0
f
c
f
0
= 240 + 60 = 300 mm/hr
f = 60 +
240
e
4.8t
(ii) Cumulative infiltration curve
(a) F = at
n
, kostiakov
Plot t vs. F on log-log paper, Fig. 3.11 (c).
log F = log a + n log t
i.e., y = c + mx form, yields a straight line,
when t = 1, a = F = 5.8
4
.
2
7
c
m
F = 132
1
Log-log paper
F = 5.8 t +1
0.69
6.2 cm
F = 27
2
F = 5.8, t = 1
= a or ab
t
2
t
1
S
l
o
p
e
n
=
=
0
.
6
9
4
.
2
7
6
.
2
300
200
150
100
80
60
50
40
30
20
15
10
8
6
5
4
1 2 3 5 7 10 15 20 30 40 60 80100 200 400 700 1000
4
5
6
8
10
20
30
40
50
60
80
100
150
200
300
1 100 1000
Time t (min)
C
u
m
.
i
n
f
i
l
t
r
a
t
i
o
n
F
(
m
m
)
10
Fig. 3.11(c) Cumulative infiltration plot
also, log
F
F
1
2
= n log
t
t
1
2
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 81
WATER LOSSES 81

F
F
1
2
=
t
t
n
1
2
F
H
G
I
K
J
132
27
=
100
10
F
H
G
I
K
J
n
n = 0.69, also from the plot, Fig. 3.11 (c)
F = 5.8 t
0.69
f =
dF
dt
= 5.8 0.69 t
0.31
i.e., f =
4
t
0.31
(b) F = at
n
+ b
log F = log ab + n log t, yields straight line plot, Fig. 3.11 (c)

F
F
1
2
=
t
t
n
1
2
F
H
G
I
K
J
n = 0.69 = slope from the plot
when t = 1, F = ab = 5.8, from the plot, Fig. 3.11 (c)
Try b = 1, a =
5 8
1
.
= 5.8
F = 5.8 t
0.69
+ 1
say t = 25 min, F = 5.8 (25)
0.69

+ 1 = 55 mm
also f =
dF
dt
= 5.8 0.69 t
0.32
i.e., f =
4
0.31
t
, at t = 25 min, f = 1.48 mm/min or 86 mm/hr
which are very near the observed values; otherwise a second trial value of b is necessary.
3.10 INFILTRATION INDICES
The infiltration curve expresses the rate of infiltration (cm/hr) as a function of time. The area
between the rainfall graph and the infiltration curve represents the rainfall excess, while the
area under the infiltration curve gives the loss of rainfall due to infiltration. The rate of loss is
greatest in the early part of the storm, but it may be rather uniform particularly with wet soil
conditions from antecedent rainfall.
Estimates of runoff volume from large areas are sometimes made by the use of infiltra-
tion indices, which assume a constant average infiltration rate during a storm, although in
actual practice the infiltration will be varying with time. This is also due to different states of
wetness of the soil after the commencement of the rainfall. There are three types of infiltration
indices:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 82
82 HYDROLOGY
(i) -index (ii) W-index (iii) f
ave
-index
(i) -indexThe -index is defined as that rate of rainfall above which the rainfall
volume equals the runoff volume. The -index is relatively simple and all losses due to infiltra-
tion, interception and depression storage (i.e., storage in pits and ponds) are accounted for;
hence,
-index =
basin recharge
duration of rainfall
...(3.14)
provided i > throughout the storm. The bar graph showing the time distribution of rainfall,
storm loss and rainfall excess (net rain or storm runoff) is called a hyetograph, Fig. 3.12. Thus,
the -index divides the rainfall into net rain and storm loss.
12
10
8
6
4
2
0
0 20 40 60 80 100 120 140 160
Time t (min)
Storm Loss
W
i
f-index
f
f
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
Rainfall, P
Runoff, P
net
P Storm loss = P
net
Fig. 3.12 Infiltration loss by -index
(ii) W-indexThe W-index is the average infiltration rate during the time rainfall in-
tensity exceeds the infiltration capacity rate, i.e.,
W-index =
F
t
P Q S
t
p
R R
=

...(3.15)
where P = total rainfall
Q = surface runoff
S = effective surface retention
t
R
= duration of storm during which i > f
p
F
p
= total infiltration
The W-index attempts to allow for depression storage, short rainless periods during a
storm and eliminates all rain periods during which i < f
p
.

Thus, the W-index is essentially
equal to the -index minus the average rate of retention by interception and depression storage,
i.e., W < .
Information on infiltration can be used to estimate the runoff coefficient C in computing
the surface runoff as a percentage of rainfall i.e.,
Q = CP ...(3.16)
C =
i W
i

...(3.16 a)
(iii) f
ave
-indexIn this method, an average infiltration loss is assumed throughout the
storm, for the period i > f.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 83
WATER LOSSES 83
Example 3.6 The rates of rainfall for the sucessive 30 min period of a 3-hour storm are:
1.6, 3.6, 5.0, 2.8, 2.2, 1.0 cm/hr. The corresponding surface runoff is estimated to be 3.6 cm.
Establish the -index. Also determine the W-index.
Solution Construct the hyetograph as shown in Fig. 3.13 (a)
(i )t = P
net
, and thus it follows
( . ) ( . ) ( . ) ( . ) 3 6 5 0 2 8 2 2
30
60
+ + +
= 3.6
= 1.6 cm/hr
P = (1.6 + 3.6 + 5.0 + 2.8 + 2.2 + 1.0)
30
60
= 8.1 cm
W-index =
P Q
t
R

=
8 1 3 6
3
. .
= 1.5 cm/hr
Suppose the same 3-hour storm had a different pattern as shown in Fig. 3.13 (b) produc-
ing the same total rainfall of 8.1 cm. To obtain the same runoff of 3.6 cm (shaded area), the
-index can be worked out as 1.82 cm/hr. Hence, it may be seen that a single determination of
-index is of limited value and many such determinations have to be made and averaged,
before the index is used. The determination of -index for a catchment is a trial and error
procedure.
6
5
4
3
2
1
0
0 30 60 90 120 150 180
Time t (min)
a. Total rain = 8.1 cm
f = 1.6
cm/hr
1.0
2.2
2.8
5.0 cm/hr
3.6
1.6
Runoff = 3.6 cm
W = 1.5 cm/hr Loss
i
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
6
5
4
3
2
1
0
0 30 60 90 120 150 180
Time t (min)
b. Total rain = 8.1 cm
5 cm/hr
4
3
2.5
1
Loss
0.7 f = 1.82
cm/hr
Storm pattern
different from a
Runoff = 3.6 cm
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
Fig. 3.13 -Index computations
3.11 SUPRA RAIN TECHNIQUE
Due to complex conditions antecedent and during the rain, and complex catchment character-
istics, the use of infiltration method is usually limited to small areas with well-established
values of infiltration.
The rainfall in excess of a particular value of -index for the entire pattern of storm
rainfall is called supra rain. Allowance for areal variation of rainfall and f-capacity is made by
dividing into sub areas in the case of large areas. The mean hourly net rains over the whole
catchment can be obtained as
P
net-mean
=

A P
A
1
1
net-1
...(3.17)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 84
84 HYDROLOGY
where A
1
, A
2
, ... are the sub-areas.
P
net1
, P
net2
, .... are the net rains in the sub areas
A
1
= A = total area of the catchment
When a large number of sub-areas are involved the hourly net rains over the whole
catchment can be derived by constructing a supra-rain-curve, in which the supra-rain is plot-
ted against hypothetical values of the -index, Fig. 3.15. The supra-rain-curve thus obtained is
valid only for that particular storm from which it is derived. For other storms, new supra rain
curves must be prepared. The supra-rain technique is illustrated in the following two exam-
ples.
Example 3.7 Hourly rainfalls of 2.5, 6, and 3 cm occur over a 20-ha area consisting 4 ha of
= 5 cm/hr, 10 ha of = 3 cm/hr, and 6 ha of = 1 cm/hr. Derive hourly values of net rain.
Solution
1st hour:
(P 2.5 cm) =
P
netmean
=
4 0 10 0 6 2 5 1
20
( ) ( ) ( . ) + +
= 0.45 cm
2nd hour:
(P 6 cm) =
P
netmean
=
4 6 5 10 6 3 6 6 1
20
( ) ( ) ( ) + +
= 3.20 cm
3rd hour:
(P 3 cm) =
P
netmean
=
4 0 10 0 6 3 1
20
( ) ( ) ( ) + +
= 0.60 cm
Total net rain for the 3-hour storm = 4.25 cm
Example 3.8 The successive hourly rains of a 10-hour storm are: 2.5, 6.3, 10, 12, 8, 5, 3, 1.5, 1
cm. Using the supra-rain-curve technique, determine the total net rain and its time distribu-
tion for a 20-hr area consisting of 4 ha of = 5 cm/hr, 10 ha of = 3 cm/hr and 6 ha of
= 1 cm/hr.
Solution For = 1 cm/hr, P
net
(supra-rain) from the hyetographFig. 3.14 is 41 cm. Similarly,
for = 0.5, 2, 3, 4, 5, 6, 7, 8, 9 and 10 cm, P
net
(supra-rain) values are 47, 33.5, 26, 21, 16, 12, 9,
6, 4 and 2 cm, respectively. With these values, the supra-rain-curve is plotted as shown in
Fig. 3.15. The supra-rain for the 20-ha area can be obtained by weighing for the sub-areas as
follows:
Sub-area index Sub-areal supra-rain A
1
/A Product (3) (4)
A
1
(cm/hr) P
net1
(decimal) (cm)
(ha) (cm)
1 2 3 4 5
4 5 16 0.2 3.2
10 3 26 0.5 13.0
6 1 41 0.3 12.3
A = 20 ha Total net rain
over basin = 28.5 cm
Corresponding to this supra-rain of 28.5 cm, the mean effective -index for the entire 20
ha, from Fig. 3.15, is 2.6 cm/hr. Application of = 2.6 cm/hr to the values of hourly rainfalls of
the 10-hr storm. Fig. 3.13 gives the values of hourly net rain as 0, 3.4, 0.4, 7.4, 9.4, 5.4, 0.4, 0
and 0 cm, respectively, giving a total of 28.8 cm.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 85
WATER LOSSES 85
Now, by working as in example 3.7, the hourly net rains are obtained in Table 3.1, which
also gives a total net rain of 28.80 cm, though the hourly net rains are slightly different from
those obtained from the supra-rain-curve technique. Thus, the supra-rain-curve technique
yields somewhat eroneous values for hourly net rains as compared with those derived by ap-
plying Eq. (3.17), though the total net rain for a given storm is the same by both techniques.
However, this loss in accuracy may be justified by the time saved, especially when a large
number of sub-areas are involved.
16
14
12
10
8
6
4
2
0
0 1 2 3 4 5 6 7 8 9 10 11
f = 2.6 cm/hr
f = 1 cm/hr
1.5
1
3
5
8
12 cm/hr
10
3
6
2.5
Time t (hr)
R
a
i
n
f
a
l
l
i
(
c
m
/
h
r
)
Fig. 3.14 Hyetograph (Example 3.8)
50
40
30
20
10
0
0 1 2 3 4 5 6 7 8 9 10 11 12
f (cm/hr)
S
u
p
r
a
r
a
i
n
P
(
c
m
/
h
r
)
n
e
t
Supra rain curve
Fig. 3.15 Supra Rain Curve (Example 3.8)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 86
86 HYDROLOGY
T
a
b
l
e

3
.
1

N
e
t

r
a
i
n

f
r
o
m

s
u
b
-
a
r
e
a
s

w
i
t
h

-
v
a
l
u
e
s
,

E
x
a
m
p
l
e

3
.
8
H
o
u
r
R
a
i
n
f
a
l
l
R
a
i
n
f
a
l
l

e
x
c
e
s
s
,

P
n
e
t

f
r
o
m

s
u
b
-
a
r
e
a
s
W
e
i
g
h
t
e
d

P
n
e
t

f
r
o
m

s
u
b
-
a
r
e
a
s
P
n
e
t

o
v
e
r

a

b
a
s
i
n
(
c
m
)
A
1
A
2
A
3
(
3
)


0
.
2
(
4
)


0
.
5
(
5
)


0
.
3
(
c
m
)


=

5

c
m
/
h
r


=

3

c
m
/
h
r


=

1

c
m
/
h
r
(
c
m
)
(
c
m
)
(
c
m
)
(
6
)

+

(
7
)

+

(
8
)
1
2
3
4
5
6
7
8
9
1
2
.
5

1
.
5

0
.
4
5
0
.
4
5
2
6
1
3
5
0
.
2
1
.
5
1
.
5
0
3
.
2
0
3
3

0
.
6
0
.
6
0
4
1
0
5
7
9
1
.
0
3
.
5
2
.
7
7
.
2
0
5
1
2
7
9
1
1
1
.
4
4
.
5
3
.
3
9
.
2
0
6
8
3
5
7
0
.
6
2
.
5
2
.
1
5
.
2
0
7
5

2
4

1
.
0
1
.
2
2
.
2
0
8
3

0
.
6
0
.
6
0
9
1
.
5

0
.
5

0
.
1
5
0
.
1
5
1
0
1

0
T
o
t
a
l

n
e
t

r
a
i
n

o
v
e
r

b
a
s
i
n

=

2
8
.
8
0

c
m
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 87
WATER LOSSES 87
3.12 WATERSHED LEAKAGE
The rain water after infiltering into the ground may percolate through the subsoil and build
up the ground water table (GWT). This ground water through the water bearing strata may
flow into the adjacent basin or directly into the sea if the water bearing strata outcrops into
the sea. This is called watershed leakage. There may be even accretion of ground water into the
basin from another nearby or remote basin if there is hydraulic interconnection through a
water bearing strata. It is this subsurface, inflow or outflow that poses problem in the water
balance studies of the basin.
3.13 WATER BALANCE
The input items into a basin are essentially precipitation (P) and subsurface inflow (G
i
) while
the water losses are evaporation (E), evapotranspiration (E
t
) and subsurface outflow (G
o
). The
balance goes to recharge ground water (G
r
), increase the soil moisture (SMA) and as surface
runoff (streamflow, R).
The water balance equation can be written as
P + G
i
= E + E
t
+ G
0
+ SMA + G
r
+ R
A case history of the water balance studies of the Krishna River basin, south India, is as
follows:
Water Balance Study of Krishna River Basin
The Krishna river Basin lies between the latitudes 13 0 N and 19 30 N and longitudes
7323 E and 8030 E, with a drainage area of 258948 km
2
and total length 1400 km in south
India. The hydrometeorological studies and water balance of the basin was made by
Subramanyam et al. (1980) employing the book keeping technique of Thornthwaite. 60 Sta-
tions were used for studying the rainfall patterns of the basin both on an annual basis and in
different seasons. Estimation of the water losses from the basin by evapotranspiration was
made by using Thornthwaites formula* for 21 stations in the basin for which the temperature
data were available. The monthly normal water balance for the whole year for the Krishna
River basin is given in Table 3.2, prepared by using the water balances of individual stations
representative of the different sections of the basin (Fig. 3.16).
The water balance study shows that the water need (1375 mm) is higher than the water
supply by precipitation (1134 mm), though an amount of 182 mm of water is recorded as rain-
fall excess (stream flow plus ground water storage (in underground formations)), on account of
concentration of rainfall from June to October compared to the lower values of water need
during these months.
*Thornthwaite formula: E
pt
= ct
a
, mm/month, where t = mean monthly temperature, C; c, a are
constants depending upon the climatic conditions of the area, latitude and the month, for specific crops.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 88
88 HYDROLOGY
SMU
SMD
SMA
G + R
r
300
mm
250
200
150
100
J F M A M J J A S O N D J
Months
50
0
mm/month
E
pt
E
t
P
P P
E
pt
SMA
191 mm
(G+R)
182
mm
SMD
24 mm
E
t
SMU
84 mm
SMD
399 mm
SMU
107 mm
E
t
P
E
pt
= E
t
P
E
pt
Fig. 3.16 Water balance of Krishna river basin (after Subramanyam et al. 1980)
Water deficiency (SMD) obtained from the water balance studies indicates the amount
of water needed for supplemental irrigations in agricultural operations, adjustment of crop
calendar (so that harvest will precede drought) and crop rotation to improve the soil structure
and increase the soil moisture storage capacity. Crop yields can increase if the moisture defi-
ciency could be avoided.
Table 3.2 Water balance for Krishna river basin (Fig. 3.16)
E
pt
P E
t
SMU SMD SMA
Month (mm) (mm) (mm) = E
t
P = E
pt
E
t
= P E
pt
(R + G
r
) R + G
r
(mm) (mm) (mm) (mm)
Jan 86 6 45 39 41
Feb 88 4 31 27 57
Mar 118 9 30 21 88
Contd.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 89
WATER LOSSES 89
April 167 32 46 14 121
May 155 57 63 6 92
June 152 165 152 13
July 90 294 90 178 26
Aug 125 233 125 108
Sept 114 159 114 45
Oct 120 123 120 3
Nov 88 45 84 39 4
Dec 72 7 52 45 20
Total 1375 1134 952 191 423 191 182
Note: E
pt
= potential evapotranspiration when there is unlimited water in the root zone, i.e., P E
pt
.
P = precipitation (mm/month)
E
t
= actual evapotranspiration (mm/month) limited to the availability of water by precipitation
and soil moisture stored; E
t
E
pt
SMU = Soil moisture utilisation (mm/month) from storage
SMD = Soil moisture deficit (mm/month) = E
pt
E
t
SMA = Soil moisture accretion (mm/month) when P > E
pt
R + G
r
= Rainfall excess (stream flow + Ground water accretion) (mm/month)
= P E
pt
SMA; after soil recharge = PE
pt
OUZ
I Choose the correct statement/s in the following:
1 The various water losses are
(i) the subsurface outflow from the basin
(ii) evaporation from ground water (when the GWT is very near the ground surface)
(iii) soil evaporation
(iv) interception by plant leaves and buildings
(v) evaporation from soil and transpiration from plant leaves in an irrigated land
(vi) all the above
2 Interception loss is
(i) more towards the end of a storm
(ii) more at the beginning of a storm
(iii) uniform throughout the storm
(iv) high in the beginning of storm and gradually decreases
3 Evaporation from water surface
(i) is proportional to the deficit of vapour pressure
(ii) increases with temperature
(iii) increases with humidity
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 90
90 HYDROLOGY
(iv) increases with the exposed area
(v) increases if there is salinity or pollution
(vi) decreases with wind velocity
(vii) increases when a film of acetyl alcohol is spread over the surface
(viii) is high in arid region
4 Evapotranspiration depends upon
(i) hours of bright sunshine (ii) wind speed
(iii) temperature (iv) humidity
(v) type of crop (vi) season of crop
(vii) stage of growth for a given crop (viii) moisture level in the soil
(ix) method of irrigation (x) all the above factors
5 Infiltration occurs at capacity rate
(i) if there had been antecedent rainfall
(ii) if the intensity of rainfall is lower than the capacity rate
(iii) if the intensity of rainfall is higher than the capacity rate
(iv) if the rainfall intensity is equal to the capacity rate
(v) during a first flash storm following summer
(vi) due to watershed leakage
(1. except i; 2. ii, iv, 3. i, ii, iv, viii ; 4. x; 5. iii, iv, v)
II Match items in A with itemts in B (more than one item in B may fit)
A B
(i) Evaporation (a) Irrigated Land
(ii) Infiltration rate (b) Plant leaves
(iii) Evaporation opportunity (c) Humid day
(iv) Low evaporation (d) -index
(v) Evapotranspiration (e) Soil evaporation
(vi) Transpiration (f) Rate of entry of rain water into soil
(g) Daltons law
(h) Land pan
(i) Float pan
(j) Blaney-Criddle formula
III Say true or false; if false, give the correct statement:
(i) Land pan can be placed directly over the land, in the vicinity of a lake or reservoir, to measure
pan evaporation.
(ii) Evaporation is significant in arid regions, while transpiration is significant in humid regions.
(iii) Evaporation is less on a humid day.
(iv) Evapotranspiration is often used synonymously with the consumptive use.
(v) Potential evapotranspiration is the evapotranspiration from a cropped land under limited
water supply to the roots.
(vi) Measurement of transpiration losses can only be made on small laboratory samples.
(vii) The value of -index depends only on the soil and is independent of the storm pattern.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 91
WATER LOSSES 91
(viii) For the same storm of the same duration, total rain and runoff (net rain), there may be
different -indices for the different storm patterns (i.e., for different time distribution of rain-
fall).
(ix) Supra-rain-curve technique yields exact values for hourly and total net rains.
(false: i, v, vii, ix)
OUE8TON8
1 (a) Explain briefly the evaporation process. What are the factors that influence the process of
evaporation ?
(b) Suggest a method of estimating evaporation from a storage reservoir.
(c) Recommend measures to reduce reservoir evaporation.
2 (a) Evaporation is less on a humid day; why ?
(b) The following were the monthly evaporation data in cm in certain year (Jan.-Dec.) in the
vicinity of a lake:
15.7 14.1 16.9 24.0 27.5 21.4
15.7 16.2 16.2 20.5 15.7 15.4
The water spread area in the lake in the beginning of January was 3.2 km
2
and at the end of
December 2.6 km
2
. Calculate the loss of water in million m
3
due to evaporation in that year.
Assume a pan coefficient of 0.71.
3 (a) Explain the difference among: evaporation, transpiration and evapotranspiration. Bring out
their significance (to a more or less degree) (i) in arid region, and (ii) in humid region.
(b) Is evapotranspiration same as consumptive use? What are the factors, which affect
evapotranspiration ?
4 (a) Can evapotranspiration be estimated from pan evaporation data? Explain.
(b) For a particular place in the month of November, the percentage sunshine hours is 7.2 and
the mean temperature is 18C. If the consumptive use coefficient for the crop is 0.7 for that
month, find the consumptive use of the crop in mm/day. (2.76 mm/day)
5 (a) Explain any one method of determining the evapotranspiration of a crop. Is it constant for
the entire crop season of that crop? If not, why?
(b) Determine the consumptive use of wheat in the month of December if the pan evaporation for
the month is 8.5 cm. Assume the growing season from November to February and consump-
tive use coefficient at 40% stage growth as 0.52. (1.47 mm/day)
6 (a) Enumerate the various water losses.
(b) What are the factors, which affect infiltration? Explain any one method of determining the
infiltration capacity of a soil surface.
7 (a) Sketch a typical curve of infiltration and give its equation. Explain with a neat sketch how
you can get such a curve for a portion of area of a river basin.
(b) A basin has 1/3 portion rocky, 1/3 portion cultivated and 1/3 portion fallow land. How do you
proceed to determine the net rain (excess rain) for the entire basin?
8 For a given basin, the following are the infiltration capacity rates at various time intervals after
the beginning of the storm. Make a plot of the f-curve and establish an equation of the form
developed by Horton for infiltration curve. Also determine the total rain and the axcess rain
(runoff).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 92
92 HYDROLOGY
Time Precipitation Infiltration capacity
(min) (cm/hr) (cm/hr)
1 5.0 4.3
2 5.0 3.9
3 5.0 3.5
4 5.0 3.2
5 6.5 3.0
6 7.5 2.8
8 7.5 2.4
10 7.5 2.2
12 7.5 2.1
14 7.5 2.0
16 2.5 1.9
18 2.5 1.85
20 2.5 1.8
22 2.5 1.8
9 (a) What are the methods available to measure infiltration ?
(b) For a drainage basin having a number of recording raingauges, the precipitation record for
each station and the total runoff from the basin are available for a series of major and minor
storms. Describe clearly how you would determine the minimum infiltration index for the
basin.
10 The infiltration capacity of an area at different intervals of time is given below. Find an equation
for the infiltration capacity curve in the exponential form:
Time: (hr) 0 0.25 0.5 0.75 1.00 1.25 1.50 1.75 2.00
Infiltration
capacit: 10.4 5.6 3.2 2.1 1.5 1.2 1.1 1.0 1.0
(cm/hr)
11 (a) Give the correct statement:
Infiltration is at capacity rates when the rainfall intensity
(i) is less than the infiltration rate of the soil.
(ii) is more than the infiltration capacity of the soil.
(b) Differentiate between : infiltration rate and infiltration capacity.
(c) The rate of rainfall for the successive 30 min period of a 3-hour storm are: 1.6, 3.6, 5.0, 2.8,
2.2, 1.0 cm/hr. The corresponding surface runoff is estimated to be 3.6 cm. Establish the
B-index. Also determine the W-index.
12 The rates of rainfall for sucessive 30 min period of 210 min storm are: 3.5, 4.0, 12.0, 8.5, 4.5, 4.5
and 3.0 cm/hr. Assuming the -index of 3.5 cm/hr, find out the net rainfall in cm, the total rain-
fall and the value of W-index. (8 cm, 20 cm, 3.43 cm/hr)
13 The average rainfall over 45 ha of watershed for a particular storm was as follows:
Time (hr): 0 1 2 3 4 5 6 7
Rainfall (cm): 0 0.5 1.0 3.25 2.5 1.5 0.5 0
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 93
WATER LOSSES 93
The volume of runoff from this storm was determined as 2.25 ha-m. Establish the -index.
(0.81 cm/hr)
14 An infiltration capacity curve prepared for a catchment indicated an initial infiltration capacity
of 2.5 cm/hr and attains a constant value of 0.5 cm/hr after 10 hours of rainfall with the Hortons
constant k = 6 day
1
. Determine the total infiltration loss.
15 Determine the runoff from a catchment of area 1.8 km
2
over which 8 cm of rainfall occurred
during 1-day storm. An infiltration capacity curve prepared indicated an initial infiltration ca-
pacity of 10 mm/hr and attained a constant value of 3 mm/hr after 16 hours of rainfall, with the
Hortons constant k = 5 hr
1
. A floating pan installed in the catchment indicated a decrease of 6
mm in water level on that day.
16 Successive hourly rainfalls of 1.5, 5 and 3 cm occur over a 25 ha area consisting of 5 ha of = 4
cm/hr, 12 ha of = 3 cm/hr and 8 ha of = 1 cm/hr. Derive the net rain in the sucessive hours.
(0.16, 2.44, 0.64 cm)
17 A 3-hour storm occurs over a 60 km
2
area. From the following data, determine the net storm rain
for the whole area and its hourly distribution.
Sub-area index Hourly rain (cm)
(km
2
) (cm/hr)
1st hr 2nd hr 3rd hr
15 2.0 1.5 5.0 1.0
20 3.2 1.5 5.0 1.0
25 1.2 1.6 5.5 1.5
(3.436 cm ; 0.17, 3.141, 0.125 cm)
18 The successive hourly rains of a 8-hour storm are: 1.5, 5, 2.6, 8, 10, 6, 3, 1 cm. Using the supra-
rain-curve technique, determine the net rain in successive hours and the total rain for a 30 ha
area consisting of 6 ha of = 3 cm/hr, 16 ha of = 2 cm/hr and 8 ha of = 1 cm/hr.
19 Write short notes on:
(i) Pan coefficient (ii) -index
(iii) Evaporation opportunity (iv) Supra rain
(v) Lysimeters (vi) Phytometers
(vii) Soil evaporation (viii) Water shed leakage
(ix) Daltons law of evaporation
20 Distinguish between
(i) -index and W-index (ii) Land pan and Infiltrometer
(iii) Infiltration capacity and Infiltration rate
(iv) Evaporation and Transpiration (v) Phytometer and Lysimeter
21 The following are the data obtained in an infiltration test.
(i) Make a plot of f-curve and establish an equation of the form developed by Horton.
(ii) Plot the cumulative infiltration curve (i.e., cumulative infiltration F
p
vs. time t) and obtain
its equation of the form F
p
= at

+ b,where a, b and are constant.


[Hint Plot F
p
(cm) vs. t (min), with t on x-axis, on log-log paper]
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 94
94 HYDROLOGY
Double Ring Infiltrometer Tests Results
Elapsed time Reading to water surface
Before filling After filling
(min)
(cm) (cm)
0 10
5 8.3 10
10 8.7 10
15 9.0 10
25 8.5 10
45 7.8 10
60 8.5 10
75 8.5 10
90 8.5 10
110 8.0 10
130 8.0 10
Ans. f
t
F t
cm hr
hr
p /
.
exp ( )
, . . = + = +
F
H
G
I
K
J
6
24
6
0 57 0 6
0 7
22 The following are the data for the first crop of rise (kuruvai) in the Cauvery delta at Thanjavur,
south India.
Growing season: June 16 to Oct. 15
Month Mean Sunshine Consumptive Effective
temp. hours use coeffi- rainfall
(C) (%) cient (cm)
June 31.0 8.60 1.15 9.2
July 30.8 8.82 1.30 10.2
Aug. 30.0 8.75 1.25 11.4
Sept. 29.5 8.26 1.10 9.4
Oct. 28.1 8.33 0.90 3.5
Determine: (a) peak consumptive use in mm/day
(b) seasonal consumptive use
(c) the total irrigation requirement assuming an irrigation efficiency of 70%
(Ans. 8.25 mm, 88.2 cm, 72.6 cm)
23 Hourly rainfalls of three storms given below yield runoff of 14, 23 and 18.5 mm, respectively.
Determine the -index for the catchment:
Hour 1 2 3 4 5 6
Storm-1 (mm) 3 8 11 4 12 3
Storm-2 (mm) 4 9 15 12 5
Storm-3 (mm) 2 6 7 10 5 4 [4.1 mm]
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD3-2.PM5 95
WATER LOSSES 95
24. A constant water level of 110 mm is maintained in an infiltration ring test by adding water
frequently as it drops down as:
Time (min) 0 5 10 15 25 45 60 75 90 110 130
since start:
Water level: 110 93 100 101 95 88 95 95 95 90 90
(mm)
Develop an infiltration equation of the Hortons type. Draw the infiltration capacity and cumula-
tive infiltration curves. [f = 60 + 180 e
5t
, mm/hr]
25. A 1
1
2
hr storm of intensity 25 mm/hr occurs over a basin for which the Hortons equation is
established as f = 6 + 16 e
2t
. Determine the depth of infiltration in the first 45 min and the
average infiltration rate for the first 75 min. Is it the same as W-index ?
(Ans. 10.7 mm, 12 mm/hr; yes 3 i > f)
Note. F =
0
t
f dt
z
, f
ave
=
F
t
; if i > f throughout the duration of storm, f
ave
= W
i
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 4
96
RUNOFF
4.1 COMPONENTS OF STREAM FLOW
When a storm occurs, a portion of rainfall infiltrates into the ground and some portion
may evaporate. The rest flows as a thin sheet of water over the land surface which is termed as
overland flow. If there is a relatively impermeable stratum in the subsoil, the infiltrating
water moves laterally in the surface soil and joins the stream flow, which is termed as underflow
(subsurface flow) or interflow, Fig. 4.1. If there is no impeding layer in the subsoil the infiltrat-
ing water percolates into the ground as deep seepage and builds up the ground water table
(GWT or phreatic surface). The ground water may also contribute to the stream flow, if the
GWT is higher than the water surface level of the stream, creating a hydraulic gradient to-
wards the stream. Low soil permeability favours overland flow. While all the three types of
flow contribute to the stream flow, it is the overland flow, which reaches first the stream
channel, the interflow being slower reaches after a few hours and the ground water flow being
the slowest reaches the stream channel after some days. The term direct runoff is used to
include the overland flow and the interflow. If the snow melt contributes to the stream flow it
can be included with the direct runoff (from rainfall).
Percolation
soil mois-
ture
G.W.T.
Soil
mois-
ture
Interflow
Ground water table
Ground water flow
Infiltration
Rainfall
Precipitation, P
Interception
loss
Infiltration
Depression storage
G
.S
.
S = Surface detention
= Sheet of water
Overland
flow
1
Impeding layer
Stream or
lake
Direct surface
runoff 1 & 2
Soil
moisture
G.W.T.
G.S.
Total runoff
1 + 2 + 3
Ground water contribution
to streamflow (Base flow)
3
2
Fig. 4.1 Disposal of rain water
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 97
RUNOFF 97
Direct surface flow can be analysed for relatively large drainage areas by the unit
hydrograph method and for smaller areas by overland flow analysis. The direct runoff results
from the occurrence of an immediately preceding storm while the ground water contribution,
which takes days or months to reach the stream, in all probability has no direct relation with
the immediately preceding storm. The ground water flow into the stream would have contin-
ued even if there had been no storm immediately preceding. It is for this reason it is termed as
base flow in hydrograph analysis.
When the overland flow starts (due to a storm) some flowing water is held in puddles,
pits and small ponds; this water stored is called depression storage. The volume of water in
transit in the overland flow which has not yet reached the stream channel is called surface
detention or detention storage. The portion of runoff in a rising flood in a stream, which is
absorbed by the permeable boundaries of the stream above the normal phreatic surface is
called bank storage, Fig. 4.2.
Low water level
Storage in permeable
banks during floods
Seepage
lines
Seepage
lines
Bank
storage
GS
River or stream
High water level
Fig. 4.2 Bank storage
4.2 CATCHMENT CHARACTERISTICS
The entire area of a river basin whose surface runoff (due to a storm) drains into the river in
the basin is considered as a hydrologic unit and is called drainage basin, watershed or catchment
area of the river flowing (Fig. 4.3). The boundary line, along a topographic ridge, separating
r
Tributaries
Main stream
Discharge
site
Q (cumec)
Basin
boundary
or divide
Axial length
Water shed, or
drainage basin, or
catchment area
A = L W
= r
b b

p
2
= L
b
Remote
fringe of
catchment
A
x
i
a
l
w
i
d
t
h
=
W
b
Equivalent circular area
A = r p
2
Circumference = 2 A p
MP
Fig. 4.3 Drainage basin characteristics
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 98
98 HYDROLOGY
two adjacent drainage basins is called drainage divide. The single point or location at which all
surface drainage from a basin comes together or concentrates as outflow from the basin in the
stream channel is called concentration point or measuring point, since the stream outflow is
usually measured at this point. The time required for the rain falling at the most distant point
in a drainage area (i.e., on the fringe of the catchment) to reach the concentration point is
called the concentration time. This is a very significant variable since only such storms of
duration greater than the time of concentration will be able to produce runoff from the entire
catchment area and cause high intensity floods.
The characteristics of the drainage net may be physically described by:
(i) the number of streams (ii) the length of streams
(iii) stream density (iv) drainage density
The stream density of a drainage basin is expressed as the number of streams per square
kilometre.
stream density, D
s
=
N
A
s
...(4.1)
where N
s
= number of streams
A = area of the basin
Drainage density is expressed as the total length of all stream channels (perennial and
intermittent) per unit area of the basin and serves as an index of the areal channel develop-
ment of the basin
Drainage density, D
d
=
L
A
s
...(4.2)
where L
s
= total length of all stream channels in the basin.
Drainage density varies inversely as the length of overland flow and indicates the drain-
age effeciency of the basin. A high value indicates a well-developed network and torrential
runoff causing intense floods while a low value indicates moderate runoff and high permeabil-
ity of the terrain.
Average stream slope =
total fall of the longest water course
length of the longest water course
Horton has suggested a method of determining the slope of large drainage areas, i.e.,
the area is subdivided into a number of square grids of equal size. The number of contours
crossed by each subdividing line is counted and the lengths of the grid lines are scaled. Then
the slope of the basin is given by
S =
15 . ( ) CI N
L
c

...(4.3)
where S = slope of the basin
CI = contour interval
N
c
= number of contours crossed by all the subdividing lines
L = total length of the subdividing lines
The boundary line along a topographic ridge, separating two adjacent drainage basins
is called the drainage divide. The line of the ground water table from which the water table
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 99
RUNOFF 99
slopes downward away from the line on both sides, is called the ground water divide. The
shape of a drainage basin can generally be expressed by:
(i) form factor (ii) compactness coefficient
Form factor, F
f
=
W
L
A
L
b
b b
=
2
...(4.4)
A = W
b
. L
b
where W
b
= axial width of basin
L
b
= axial length of basin, i.e., the distance from the measuring point (MP) to the most
remote point on the basin.
Compactness coefficient, C
c
=
P
A
b
2
...(4.5)
where P
b
= perimeter of the basin
2 A
= circumference of circular area, which equals the area of the basin.
If R is the radius of an equivalent circular area,
A = R
2
, R =
A

Circumference of the equivalent circular area = 2R = 2


A

= 2 A
The compactness coefficient is independent of the the size of the catchment and is de-
pendent only on the slope.
A fan-shaped catchment produces greater flood intensity since all the tributaries are
nearly of the same length and hence the time of concentration is nearly the same and is less,
whereas in the fern-shaped catchments, the time of concentration is more and the discharge is
distributed over a long period (Fig. 4.4).
T
r
i
b
u
t
a
r
i
e
s
M
a
i
n
s
t
r
e
a
m
Less concentration time
causes intense floods
Discharge
site
Q
Q
Remote fringe
of catchment
More concentration
time
Discharge
site
(a) Fan shaped (b) Fern (leaf) shaped
Fig. 4.4 Fan-and fern-shaped catchments
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 100
100 HYDROLOGY
Schumm S.A. (1956) used an elongation ratio (E
r
), defined as the ratio of the diameter
of a circle of the same area as the basin to the maximum basin length; the values range from
0.4 to 1.0.
Miller V.C. (1953) used a dimensionless circularity ratio (C
r
), defined as the ratio of the
basin area to the area of a circle having the same perimeter as the basin; the values range from
0.2 to 0.8.
The drainage basin characteristics influence the time lag of the unit hydrograph and
peak flow (Taylor and Scwartz, 1952).
Example 4.1 The contour map of a basin is subdivided into a number of square grids of equal
size by drawing horizontal and vertical lines as shown in Fig. P4.1. The contour interval is
25 m.
6
0
0
m
5
7
5
m
5
5
0
m
5
2
5
m
5
0
0
m
4
7
5
m
4
5
0
m
Contour
lines
Vert. grid
lines
Horz.
grid lines
Contour
intersections
Basin boundary
Fig. P4.1 Hortons grid for basin slope
The number of contour intersections by vertical lines is 75 and by horizontal lines 126.
The total length of the vertical grid segments (after multiplying by the scale) is 53260 m and of
the horizontal grid segments 55250 m. Determine the mean slope of the basin.
Solution Slope in the vertical direction
S
v
=
N C I
Y
c
. .

=
75 25
53260

= 0.0352 m/m
Slope in the horizontal direction
S
x
=
N C I
X
c
. .

=
126 25
55250

= 0.0570 m/m
Mean slope of the basin
S =
S S
v x
+
=
+
2
0 0352 0 0570
2
. .
= 0.0461 m/m or 4.61%
Also, from the Hortons equation,
S =
15 . ( . ) C I N
L
c

=
1.5 25 (75 126)
(53260 55250)
+
+
= 0.0695 or 6.95%
Example 4.2 A basin has an area of 26560 km
2
, perimeter 965 km and length of the thalweg
230 km. Determine: (i) form factor, (ii) compactness coefficient, (iii) elongation ratio, and (iv)
circularity ratio.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 101
RUNOFF 101
Solution (i) Form factor, F
f
=
A
L
b
2
=
26560
230
2
= 0.502
An inverted factor will give 2
(ii) Compactness Coefficient C
c
Radius R of an equivalent circular area is given by
26560 = R
2
R = 91.9 km
C
c
=
P
R
b
2
965
2 919
=
( . )
= 1.67
(iii) Elongation ratio E
r
=
2 2 919
230
R
L
b
=
( . )
= 0.8
(iv) Circularity ratio C
r
Radius R of a circle of an equivalent perimeter as the basin is given by
2R = 965 R = 153.5 km
C
r
=
A
R
=
2 2
26560
1535 ( . )
= 0.358
4.3 MEAN AND MEDIAN ELEVATION
The mean elevation is determined as the weighted average of elevations between two adjacent
contours.
The mean elevation of a drainage basin is given by
z
b
=

a z
a
1 1
1
...(4.6)
where z
b
= mean elevation of the drainage basin
a
1
,a
2
= areas between the successive contours of the basin
z
1
, z
2
= mean elevations between the two successive contours
a
1
= A = area of the basin
Area-elevn. curve
Mean El. 358 m
Median El. 350 m 350 m
Noyyil river basin
Coimbatore, S-India
800
700
600
500
800
400
300
200
100
0
E
l
e
v
a
t
i
o
n
(
m
)
0 10 20 30 40 50 60 70 80 90 100
(%) Area above various elevations
Fig. 4.5 Hypsometric curve (Example 4.2)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 102
102 HYDROLOGY
The median elevation is the elevation at 50% area of the catchment and is determined
from the area-elevation curve. The area elevation curve is obtained by plotting the contour
elevation against area or percent of area, above or below that elevation, Fig. 4.5. The area-
elevation curve is also called the hypsometric curve for the basin and is illustrated in the
following example.
Example 4.3 The areas between different contour elevations for the Noyyil River basin,
Coimbatore (south India) are given below. Determine the mean and the median elevation for
the basin.
Contour elevations Area between contours
(m) (km
2
)
< 225 181
225300 723
300375 1144
375450 814
450525 216
525600 46
>600 140
Solution
Table 4.1 Computation of mean elevation of basin.
Mean elevation Area Product Mean
Contour between between a
1
z
1
elevation
elevation contours, z
1
contours, a
1
(2) (3)
(m) (m) (km
2
) (km
2
m) (m)
1 2 3 4 5
<225 200 181 36200
225-300 262.5 723 190000 z
b
=

a z
a
1 1
1
300-375 337.5 1144 386000
375-450 412.5 814 335500 =
1169940
3264
450-525 487.5 216 105400 = 358 m
525-600 562.5 46 25840
>600 650 140 91000
3264 1169940
= a
1
= A = a
1
z
1
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 103
RUNOFF 103
Table 4.2 Computation of median elevation of basin.
Contour Area between Percentage of % of total area
elevations contours, a
1
total area over given
(m) (km
2
) (%) lower limit
<225 181 5.5 100.0
225-300 723 22.1 94.5
300-375 1144 35.1 72.4
375-450 814 25.0 37.3
450-525 216 6.6 12.3
525-600 46 1.4 5.7
<600 140 4.3 4.3
A = 3264
The hypsometric curve is obtained by plotting the contour elevation (lower limit) against
the corresponding percent of total area, Fig. 4.5; the median elevation for 50% of total area is
read from the curve as 350 m, while the mean elevation is 358 m (Table 4.1).
4.4 CLASSIFICATION OF STREAMS
Streams may be classified as:
(i) Influent and Effluent streams
(ii) Intermittent and perennial streams
(i) Influent and Effluent streams. If the GWT is below the bed of the stream, the seep-
age from the stream feeds the ground-water resulting in the build up of water mound (Fig. 4.6).
Such streams are called influent streams. Irrigation channels function as influent streams and
many rivers which cross desert areas do so. Such streams will dry up completely in rainless
period and are called ephemeral streams. The ephemeral streams, generally seen in arid re-
gions, which flow only for a few hours after the rainfall, are of no use for conventional
hydropower. However, they can occasionally be used in pure pumped storage schemes, where
the actual consumption of water is only marginal.
Low water level
High water level
Seepage
lines Ground water
recharge
Seepage
lines
Ground water mound
GWT
Stream feeds ground water
Fig. 4.6 Influent streams
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 104
104 HYDROLOGY
When the GWT is above water surface elevation in the stream, the ground water feeds
the stream, Fig. 4.7. Such streams are called effluent streams. The base flow of surface streams
is the effluent seepage from the drainage basin. Most of the perennial streams are mainly
effluent streams.
Bank storage
High water level
Low water level
G.W.T.
Ground water feeds
the stream (Base flow)
GWT
Ground water flow
Fig. 4.7 Effluent streams
(ii) Intermittent and perennial streams. If the GWT lies above the bed of the stream
during the wet season but drops below the bed during the dry season, the stream flows during
wet season (due to surface runoff and ground water contribution) but becomes dry during dry
seasons. Such streams are called intermittent streams.
While in the case of perennial streams, even in the most severe droughts, the GWT
never drops below the bed of the stream and therefore they flow throughout the year. For
power development a perennial stream is the best; power can also be generated from intermit-
tent streams by providing adequate storage facilities.
4.5 ISOCHRONES
The lines joining all points in a basin of some key time elements in a storm, such as
beginning of precipitation, are called isochrones (Fig. 4.8). They are the time contours and
represent lines of equal travel time and they are helpful in deriving hydrographs.
Discharge
site
Q
I
II
III
IV V
400
ha
900 ha
800 ha
500 ha
200 ha
Isochrones
20.00 hr
21.00 hr
22.00 hr
23.00 hr
Direction of
storm movement
Fig. 4.8 Isochrones
4.6 FACTORS AFFECTING RUNOFF
The various factors, which affect the runoff from a drainage basin depend upon the
following characteristics:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 105
RUNOFF 105
(i) Storm characteristics
Type or nature of stormand
season
Intensity
Duration
Areal extent (distribution)
Frequency
Antecedent precipitation
Direction of stormmovement
R
S
|
|
|
|
T
|
|
|
|
(ii) Meteorological characteristics
Temperature
Humidity
Wind velocity,
Pressure variation
R
S
|
T
|
(iii) Basin characteristics
Size
Shape
Slope
Altitude (elevation)
Topography
Geology (type of soil)
Land use /vegetation
Orientation
Type of drainage net
Proximity to ocean and mountain
ranges
R
S
|
|
|
|
|
|
T
|
|
|
|
|
|
(iv) Storage characteristics
Depressions
Pools and ponds / lakes
Stream
Channels
Check dams (in gullies)
Upstreamreservoir /or tanks
Flood plains, swamps
Ground water storage in pervious
deposits (aquifers)
R
S
|
|
|
|
|
T
|
|
|
|
|
Low intensity storms over longer spells contribute to ground water storage and produce
relatively less runoff. A high intensity storm or smaller area covered by it increases the runoff
since the losses like infiltration and evaporation are less. If there is a succession of storms, the
runoff will increase due to initial wetness of the soil due to antecedent rainfall. Rain during
summer season will produce less runoff, while that during winter will produce more.
Greater humidity decreases evaporation. The pressure distribution in the atmosphere
helps the movement of storms. Snow storage and specially the frozen ground greatly increase
the runoff.
Peak runoff (if expressed as cumec/km
2
) decreases as the catchment area increases due
to higher time of concentration. A fan-shaped catchment produces greater flood intensity than
a fern-shaped catchment.
Steep rocky catchments with less vegetation will produce more runoff compared to flat
tracts with more vegetations. If the vegetation is thick greater is the absorption of water, so
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 106
106 HYDROLOGY
less runoff. If the direction of the storm producing rain is down the stream receiving the sur-
face flow, it will produce greater flood discharge than when it is up the stream. If the catch-
ment is located on the orographic side (windward side) of the mountains, it receives greater
precipitation and hence gives a greater runoff. If it is on the leeward side, it gets less precipi-
tation and so less runoff. Similarly, catchments located at higher altitude will receive more
precipitation and yield greater runoff. The land use patternarable land, grass land, forest or
cultivated area, greately affect runoff.
The storage in channels and depressions (valley storage) will reduce the flood magni-
tude. Upstream reservoirs, lakes and tanks will moderate the flood magnitudes due to their
storage effects. For drainage basins having previous deposits, large ground water storage may
be created, which may also contribute to the stream flow in the form of delayed runoff.
4.7 ESTIMATION OF RUNOFF
Runoff is that balance of rain water, which flows or runs over the natural ground surface after
losses by evaporation, interception and infiltration.
The yield of a catchment (usually means annual yield) is the net quantity of water
available for storage, after all losses, for the purposes of water resources utilisation and plan-
ning, like irrigation, water supply, etc.
Maximum flood discharge. It is the discharge in times of flooding of the catchment area,
i.e., when the intensity of rainfall is greatest and the condition of the catchment regarding
humidity is also favourable for an appreciable runoff.
Runoff Estimation
The runoff from rainfall may be estimated by the following methods:
(i) Empirical formulae, curves and tables
(ii) Infiltration method
(iii) Rational method
(iv) Overland flow hydrograph
(v) Unit hydrograph method
(vi) Coaxial Graphical Correlation and API (See art. 13.4 and Ex. 13.3 in Chapter 13)
The above methods are discussed as follows :
(i) Empirical formulae, curves and tables. Several empirical formulae, curves and tables
relating to the rainfall and runoff have been developed as follows:
Usually, R = a P + b ...(4.7)
sometimes, R = a P
n
...(4.8)
where R = runoff, P = rainfall, a, b, and n, are constants. Eq. (4.7) gives a straight line plot on
natural graph paper while Eq. (4.8) gives an exponential curve on natural graph paper, Fig. 4.9 a
and a straight line plot on log-log paper Fig. 4.9 b; the constants can be obtained from the
straight line plots as shown in Fig. 4.9. Also see Chapter 13, and Ex. 13.4 with Computer
ProgramC.
For example, C.C. Inglis formula for BombayDeccan catchments (Ghat areas)
R = 0.85P + 30.5 ...(4.9)
and for plains R =
( . ) P P 17 8
254
...(4.10)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 107
RUNOFF 107
R = aP
n
Slope n
a = R, when P = 1
b. Log-log paper
R
u
n
o
f
f
R
(
c
m
)
100
10
1
1 10 100 1000
1
2
3
4
6
8
1
2
3
4
6
8
1
1 8 6 4 3 2 1 8 6 4 3 2 1 8 6 4 3 2 1
Precipitation P (cm)
R = aP
Slope a
b (b is negative)
Precipitation P (cm)
R = + aP b
R = aP
n
R
u
n
o
f
f
R
(
c
m
)
a. Natural graph
paper
0
Slope a
=
dy
dx
dy
dx
Fig. 4.9 Rainfall-Runoff correlation
Laceys formula for Indo-Gangetic plain
R =
P
P
F
S
1
304 8
+
F
H
G
I
K
J
.
...(4.11)
where F is a monsoon duration factor varying between 0.5 to 1.5 and S is the catchment factor
depending upon the slope and varies from 0.25 for flat areas to 3.45 for hilly areas
A.N. Khoslas formula for north India
R = P
T
374 .
...(4.12)
Formulae for some of the drainage basins in India:
Ganga basin R = 2.14 P
0.64
...(4.13)
Yamuna basin (Delhi) R = 0.14 P
1.1
...(4.14)
Rihand basin (U.P.) R = P 1.17 P
0.86
...(4.15)
Chambal basin (Rajasthan) R = 120P 4945 ...(4.16)
Tawa basin (M.P.) R = 90.5P 4800 ...(4.17)
Tapti basin (Gujarat) R = 435P 17200 ...(4.18)
In the above formulae, R is the average annual runoff in cm, P is the average annual
rainfall in cm, T is the mean annual temperature in C for the entire drainage basin.
In addition to the above, several investigators have presented the rainfall-runoff rela-
tionships in the form of curves and tables such as
(a) Binnies percentages (tables) for catchments in Madhya Pradesh
(b) Stranges curves and tables for Bombay-Deccan catchments
(c) Barlows tables for runoff coefficients in UP
Reference may be made to some of the Indian irrigation text-books, for the details and
utility of the above curves and tables.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 108
108 HYDROLOGY
The yield of a catchment can be simply worked out by taking about 75 to 80% of the
a.a.r. and assuming a suitable runoff coefficient.
The rainfall of an average bad year
2
3
to
3
4
of the a.a.r., which may be taken for runoff
computation. Further improvement over the a.a.r. is the dependable rainfall. The available
annual rainfall records for about 35 years are arranged in the descending order and the rainfall
of 75% dependability, i.e., of the 27th year from the top is taken for runoff computation.*
Several empirical formulae have also been developed for estimating the maximum rate
of runoff or Maximum Flood Discharge (MFQ) and these are given under Chapter8 on Floods.
(ii) Infiltration Method. By deducting the infiltration loss, i.e., the area under the infil-
tration curve, from the total precipitation or by the use of infiltration indices, which are al-
ready discussed. These methods are largely empirical and the derived values are applicable
only when the rainfall characteristics and the initial soil moisture conditions are identical to
those for which these are derived.
(iii) Rational Method. A rational approach is to obtain the yield of a catchment by as-
suming a suitable runoff coefficient.
Yield = CAP ...(4.19)
where A = area of catchment
P = precipitation
C = runoff coefficient
The value of the runoff coefficient C varies depending upon the soil type, vegetation
geology etc. and the following Table 4.3 given by Richards may be taken as a guide.
Table 4.3 Runoff coefficients for various types of catchments
Type of catchment Value of C
Rocky and impermeable 0.81.0
Slightly permeable, bare 0.60.8
Cultivated or covered with vegetation 0.40.6
Cultivated absorbent soil 0.30.4
Sandy soil 0.20.3
Heavy forest 0.10.2
In the rational method, the drainage area is divided into a number of sub-areas and
with the known times of concentration for different subareas the runoff contribution from
each area is determined. The choice of the value of the runoff coefficient C for the different
sub-areas is an important factor in the runoff computation by this method. This method of
dividing the area into different zones by drawing lines of time contour, i.e., isochrones, is
illustrated in the following example.
*Frequency F =
m
n
100 75% =
m
35
100 m = 27
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 109
RUNOFF 109
Example 4.3 A 4-hour rain of average intensity 1 cm/hr falls over the fern leaf type catchment
as shown in Fig. 4.10. The time of concentration from the lines AA, BB, CC and DD are 1, 2, 3
and 4 hours, respectively, to the site 0 where the discharge measurements are made. The values
of the runoff coefficient C are 0.5, 0.6, and 0.7 for the 1st, 2nd and 3rd hours of rainfail respec-
tively and attains a constant value of 0.8 after 3 hours. Determine the discharge at site 0.
Q
Discharge
site
I
II
III
IV
20 ha
t
=
1
h
r
c
t
=
2
h
r
c
t
=
3
h
r
c
t
=
4
h
r
c
40 ha
50 ha 30 ha
Catchment
area
Isochrones
Basin
boundary
C
B
A
D
D
C
B
A
O
Fig. 4.10 Time of concentration method of runoff computation (Example 4.3)
Solution The discharge computations are made in Table 4.4.
Example 4.4 The following data are collected for a proposed tank in the Deccan plains of south
India:
Catchment area = 1200 ha
a.a.r. = 90 cm
Intensity of rainfall of duration 1 hr
and frequency 35 years = 5 cm/hr
Average runoff cofficient for the
whole catchment = 20%
Tank gets filled = 1
1
2
times in a year
Difference between the maximum
water level (MWL) and full tank
level (FTL) = 0.6 m
Determine
(a) the yield of the catchment and the capacity of the tank
(b) the area of rice crop that can be irrigated from the tank
(c) the duties of water assumed and the discharge at the head to the distributary
(d) the length of clear overfall weir near one flank.
Solution A.A.R. is available only in 50% of the years. To ensure filler of the tank in deficient
years dependable rainfall 75% of a.a.r.
= 0.75 90 = 67.5 cm or 0.675 m.
Corresponding to this rain (P) of 75% dependability, the runoff (R) can be found from
Eq. (4.10).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 110
110 HYDROLOGY
S
u
b
-
a
r
e
a

(
z
o
n
e
)
T
i
m
e

f
r
o
m

b
e
g
i
n
n
i
n
g

o
f

s
t
o
r
m

(
h
r
)
c
o
n
t
r
i
b
u
t
i
n
g
r
u
n
o
f
f

(
h
a
)
1
2
3
4
5
6
7
8
I
2
0
2
0
2
0
2
0
I
I
3
0
3
0
3
0
3
0
I
I
I
5
0
5
0
5
0
5
0
I
V
4
0
4
0
4
0
4
0

D
i
s
c
h
a
r
g
e

a
t

0
f
r
o
m

s
u
b
-
a
r
e
a
s
0
.
5

(
2
0

0
.
6

(
2
0

0
.
7

(
2
0

0
.
8

(
2
0

Q

=

C
A
P
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
0
.
5

(
3
0

0
.
6

(
3
0

0
.
7

(
3
0

0
.
8

(
3
0

1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
0
.
5

(
5
0

0
.
6

(
5
0

0
.
7

(
5
0

0
.
8

(
5
0

1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
0
.
5

(
4
0

0
.
6

(
4
0

0
.
7

(
4
0

0
.
8

(
4
0

1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
1
0
4
)

1
1
0
0
D
i
s
c
h
a
r
g
e

a
t

0
1
0
0
0
2
7
0
0
5
7
0
0
8
7
0
0
8
3
0
0
6
8
0
0
3
2
0
0

Q

(
m
3
/
h
r
)
T
a
b
l
e

4
.
4

T
i
m
e

o
f

c
o
n
c
e
n
t
r
a
t
i
o
n

m
e
t
h
o
d

o
f

r
u
n
o
f
f

c
o
m
p
u
t
a
t
i
o
n
.

(
E
x
a
m
p
l
e

4
.
3
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 111
RUNOFF 111
R =
( . ) P P 17 8
254
=
( . . ) . 67 5 17 8 67 5
254

= 13.2 cm
Since the runoff coefficient C = 20% (given)
R = CP = 0.20 67.5 = 13.5 cm
which compares well with the value obtained above by applying the empirical formula for the
region.
Yield from the catchment = CAP = 0.2 1200 0.675 = 162 ha-m
Since the tank gets filled 1
1
2
times in a year,
Capacity of the tank =
162
15 .
= 108 ha-m
(b) Assuming loss of water due to evaporation and seepage as 10% in the tank and 20%
in the distributary
Water available at the field outlet = 162 (1 0.3) = 113.4 ha-m
For rice crop assuming U = 88 cm, crop period B = 120 days
Field irrigation requirement =
U

irrgn
=
88
0 7 .
= 126 cm or 1.26 m = 1.26 ha-m/ha
Area of rice crop that can be irrigated
=
113.4 h m
1.26 m

= 90 ha
(c) Tank duty =
1 0 3
126
.
.
= 0.555 ha/ha-m of annual storage (i.e., yield)
For 1 Mm
3
:
(1 0.3) 10 m
1.26 10 m / ha
6 3
4 2

= 55.5 ha/Mm
3
of annual storage
Note: 162 0.555 = 90 ha
Flow duty (D) as ha/cumec on field can be obtained from equal volumes
1
m
sec
3
(B days 86400 sec) = (D 10
4
m
2
) m
D =
8 64 . B

=
8.64 120 days
1.26 m
= 823 ha/cumec
Discharge at field outlet =
90
823
= 0.1093 cumec
Discharge at the head of the distributary, i.e., tank outlet
= 0.1093/0.80 = 0.137 cumec = 137 lps
(d) Length of the clear overfall weir (L):
Using the rational formula for the maximum rate of runoff
Q = CiA = 0.2
5
100 60 60 ( )
(1200 10
4
) = 33.3 cumec
Weir formula is Q = CLH
3/2
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 112
112 HYDROLOGY
Head over the weir H = MWL FTL = 0.6 m, L = length of the weir
Assuming a weir coefficient C of 1.84, the weir formula becomes
33.3 = 1.84 L (0.6)
3/2
L = 39 m
Note. This example helps to distinguish between the hydrologic design and the hydraulic design.
The hydrologic design consists of arriving at the minimum rate of runoff (yield) and maximum rate of
runoff (flood) from a catchment, while the hydraulic design helps to design the storage capacity of the
tank, the tank outlet, the outlet on the field, the design of the distributary (as open channel) and the
length of the clear overfall weir and other apurtenances (from the principles of hydraulic engineering).
Similarly hydrologic studies are made to arrive at the design flood for a spillway or bridge, and the
hydraulic design consists of computing the length of spillway (for a desired head over the spillway) or
calculating HFL, afflux and lineal water way for bridge openings, etc.
(iv) Overland Flow Hydrograph. Overland flow occurs as a thin sheet of water over the
ground surface (soon after a storm starts), joins a stream channel, and then flows in the chan-
nel to the concentration point. Overland flow is relatively slow and is the dominant type of
flow in the case of very small areas such as air ports, municipal block areas and flow from
broad surfaces into storm drains and gutters. But in the case of large drainage areas, the
length of overland flow is so short in comparison with the channel flow distance (before reaching
the concentration point) that the total concentration time is mainly a function of channel velocity.
Overland flow is essentially a uniform flow over the surface (Fig. 4.11) as developed by
C.F. Izzard (1948). The Reynolds number
R
e
=
Vd q

=
...(4.20)
where V = velocity of flow
d = uniform depth of flow
= kinematic viscosity of water
q = discharge per unit width
W
a
te
r s
h
e
e
t
P
1
y
t
0
w
s
in
a
P
2
a
a
W
D
x
W
a
te
r
s
u
r
fa
c
e
L
a
n
d
s
u
r
fa
c
e
+
s
lo
p
e
s
S
a D
F = 0 per unit width
P P + w sin ( x.1) = 0
s
1 2 0
t
Fig. 4.11 Laminar overland flow analysis (after C.F. Izzard, 1948)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 113
RUNOFF 113
Experiments indicate that the overland flow can be assumed to be laminar if R
e
1000
and turbulent if R
e
> 1000 with a transition region of uncertainity in the vicinity of R
e
= 1000.
Izzard suggested that for rectangular drainage areas, laminar flow can be assumed if the
product i
net
l > | 400, where i
net
is the net rainfall in cm/hr and l is the length of overland flow
in metres. Finite difference methods, based upon the method of characteristics have also been
used to develop overland flow hydrographs.
(v) Unit Hydrograph Method. The hydrograph of direct surface discharge measured at
the outlet of drainage area, which produces a unit depth of direct runoff (i.e., a P
net
of 1 cm over
the entire area of the catchment) resulting from a unit storm of specified duration (called unit
period) is called a unit hydrograph of that duration. The unit hydrograph method was first
proposed by L.K. Sherman in 1932. The area under the hydrograph represents a direct runoff
of 1 cm, Fig. 4.12.
Time t (hr)
T
Runoff duration (hr)
t
time of
concentration
c
Unit hydrograph
Inflection point
Area under the
curve = runoff
volume of 1-cm depth
over catchment
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
O
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
t
2
r
Q
p
t
p
Basin lag (hr)
Peak, Q
p
Time t (hr)
t
r
= duration of storm (i = 1/t cm/hr)
r
cg of P
net
P = net storm rain of 1 cm
net
Fig. 4.12 Unit hydrograph
The theory of unit hydrograph is based on the following assumptions:
(i) The net rainfall is of uniform intensity within its duration (i.e., unit period).
(ii) The net rainfall uniformly occurs over the entire area of the drainage basin.
(iii) For a given drainage basin, the base period of the hydrographs of direct runoff cor-
responding to net rains of different intensities but same unit duration, is constant.
(iv) The ordinates of direct runoff hydrographs due to net rains of different intensities
(but same unit duration) are proportional.
(v) A unit hydrograph reflects all the physical characteristicts of the basin.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 114
114 HYDROLOGY
Application of the Unit Hydrograph. First a unit hydrograph of suitable unit duration is
derived from an observed flood hydrograph for the drainage basin due to a known storm (storm
loss and net rain). The unit hydrograph so derived can be applied for any other storm (of the
same duration but producing different net rain) occurring on the basin and the resulting flood
hydrographs can be obtained.
The details of the derivation of unit hydrographs and their application, given a unit
hydrograph of one duration to derive a unit hydrograph of some other duration, and derivation
of unit hydrographs for meteorologically homogeneous catchments (i.e., from basin
characteristics like shape, size, slope etc. when the stream-outflows are not gauged) are given
in Chapter5.
Example 4.5 A small watershed consists of 1.5 km
2
of cultivated area (c = 0.2), 2.5 km
2
under
forest (c = 0.1) and 1 km
2
under grass cover (c = 0.35). There is a fall of 20 m in a watercourse of
length 2 km. The IDF relation for the area is given by I =
80 T
(t 12)
0.2
0.5
+
, I in cm/hr, Tyr, t-min.
Estimate the peak rate of runoff for a 25-year frequency.
Solution Time of concentration (Kirpichs formulamodified)
t
c
0.02 L
0.8
S
0.4
, t
c
in min, L in metres
= 0.02 (2000)
0.8

20
2000
0.4
F
H
G
I
K
J

= 55 min = t
I =
80 25
55 12
0.2
0.5

+ ( )
= 18.6 cm/hr
Q = CIA = 2.78 I ( C
i
A
i
) = 2.78 18.6 (1.5 0.2 + 2.5 0.1 + 1 0.35)
= 46.5 Cumec
OUZ V
I Match the items in A with the items in B
A B
(i) Isochrone (a) C.F. Izzard
(ii) Runoff coefficient (b) Topographic ridge
(iii) Unit hydrograph (c) Arid region
(iv) Compactness coefficient (d) Perennial streams
(v) Effluent streams (e) Shape of drainage basin
(vi) Ephemeral streams (f) 1 cm of runoff
(vii) Drainage divide (g) Yield of catchment
(viii) Overland flow hydrograph (h) Time-contours of commencement of storm
II Say true or false if false, give the correct statement.
(i) Direct runoff is the sum of overland flow and interflow.
(ii) In a perennial stream the ground water table is always below the bed of the stream while the
ground water table is always above the bed in an ephemeral stream.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 115
RUNOFF 115
(iii) Bank storage is the portion of runoff stored in the permeable banks of a stream due to a
rising flood.
(iv) The drainage density varies directly as the length of overland flow and indicates the drain-
age efficiency of the basin.
(v) Quick intense floods occur more in fern-shaped catchments than in fan-shaped catchments.
(vi) For the same intensity of rainfall, the flood discharge from a relatively small catchment is
higher than that from a relatively large catchment.
(vii) Vegetation tends to increase the runoff from the catchment. (false: ii, iv, v, vii)
III Choose the correct statement/s in the following:
1 Maximum surface runoff is favoured due to
(i) presence of forest area
(ii) a flash storm
(iii) presence of a recharge area, which replenishes the ground water storage
(iv) leaf-shaped catchment
(v) fan-shaped catchment
(vi) storm movement opposite to the stream flow
(vii) humid climate
(viii) improved land management
2 An influent stream is due to
(i) a river crossing a desert area
(ii) effluent seepage from the basin
(iii) ground water table being above the stream bed
(iv) base flow
(v) direct surface runoff
(vi) being ephemeral in nature (1ii, v, vii; 2i, v, vi)
OUE8TON8
1 Name three forms in which water is stored on a catchment.
2 What is meant by the water balance of a catchment?
3 Dicuss the various factors, which affect the runoff from a basin.
4 (a) What are the methods of estimating runoff from a catchment?
(b) Give three empirical formulae applicable to particular regions in India.
5 How do you determine the yield from a catchment and arrive at the capacity of a tank?
6 Differentiate: Runoff, yield and maximum flood discharge.
7 Determine the yield of the catchment and the capacity of the tank from the following data:
Catchment area = 20 km
2
a.a.r. = 80 cm
Tank gets filled: 2 times in a year
Runoff coefficient =
1
5
(average for the catchment) (2, 4, 1.2 Mm
3
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD4-1.PM5 116
116 HYDROLOGY
8 Explain the terms: catchment area and drainage divide.
An irrigation tank has a catchment area of 30 km
2
and receives an annual rainfall of 90 cm.
Assuming that 10% of the rainfall flows as runoff from the catchment, calculate the area that
can be brought under paddy cultivation under the tank. Assume that the tank fills one and a half
times in a year and the water requirement of paddy (duty) is 100 ha-cm. (40.5 ha)
9 (a) Explain how the following physical characteristics of a catchment can be determined?
(i) Mean elevation
(ii) Mean slope
(b) Krishna River basin has an area of 258948 km
2
and length 1400 km. Calculate the form
factor and elongation ratio. (0.132, 0.41)
10 Explain the terms: Catchment area, Drainage divide, and Ground water divide. An irrigation
tank has a catchment area of 30 km
2
and the a.a.r. is 90 cm. Assuming that only 20% of the
dependable rainfall is the runoff available. Calculate the capacity of the tank assuming that it
fills one and a half times in a year.
Assuming a total depth of irrigation water for rice crop for 120 days as 1.25 m and 30% losses,
what area of rice crop can come under the tank?
Work out the tank duty, field duty and the discharge required at the tank outlet.
What is the length of the clear overfall weir to dispose of flood waters, assuming an intensity of
5 cm/hr of 35-year frequency. (270 ha-m, 227 ha, 56 ha/Mm
3
, 828 ha/cumec, 343 lps, 97.5 m)
11 A catchment has a perimeter of 1020 km and an area of 38520 km
2
. Calculate the compactness
coefficient.
12 Write short notes on
(i) Isochrones (ii) Ephemeral streams
(iii) Time of concentration (iv) Overland flow hydrograph
(v) Runoff cycle (vi) Valley storage
(vii) Bank storage
13 Distinguish between
(i) Overland flow and interflow (ii) Influent and effluent streams
(iii) Detention storage and depression storage
(iv) Drainage density and drainage divide
(v) Form factor and compactness coefficient of a catchment
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
5.1 HYDROGRAPH COMPONENTS
A hydrograph is a graph showing discharge (i.e., stream flow at the concentration point)
versus time. The various components of a natural hydrograph are shown in Fig. 5.1. At the
beginning, there is only base flow (i.e., the ground water contribution to the stream) gradually
depleting in an exponential form. After the storm commences, the initial losses like intercep-
tion and infiltration are met and then the surface flow begins. The hydrograph gradually rises
Effective duration
of net rain
Rainfall, P
Net rain, P
net
C.g of P
net
f-curve
(loss rate)
Infil-
tration loss
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Time t (hr or days)
B.F. Separation line
Ground water contribution
of stream flow (base flow B.F.)
2
Ground water
depletion curve
Point
of rise
Rising
limb
Direct surface
runoff volume
= P A
net
1
Time of
concentration
t
c
Inflection
point
Basin lag
t
p
P
net
= P Losses
N days after peak
Peak flow
Crest
Total runoff hydrograph (TRH)
of stream-flow =
1 + 2
Recession limb or
curve (or falling limb)
Ground water
depletion curve extrapolated
Elevated
ground water table contributes more
GW depletion curve
N days after peak
N(days) = (empirical)
A = Area of basin (km
2
)
A
1.21
0.2
Time t (hr or min)
Hyetograph
Fig. 5.1 Components of streamflow hydrograph
Chapter 5
117
HYDROGRAPHS
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 118
118 HYDROLOGY
and reaches its peak value after a time t
p
(called lag time or basin lag) meaured from the
controid of the hyetograph of net rain. Thereafter it declines and there is a change of slope at
the inflection point, i.e., there has been, inflow of the rain up to this point and after this there
is gradual withdrawal of catchment storage. By this time the ground water table has been
built up by the infiltrating and percolating water, and now the ground water contributes more
into the stream flow than at the beginning of storm, but thereafter the GWT declines and the
hydrograph again goes on depleting in the exponential form called the ground water depletion
curve or the recession curve. If a second storm occurs now, again the hydrograph starts rising
till it reaches the new peak and then falls and the ground water recession begins, Fig. 5.2.
Storm 1
Storm 2
Storm 3
P
net
1 P
net
2
P
net
3
Loss Loss Loss
3 peaks due to
3-storms in
succession
Recession
lines
Estimated base flow
Time t (hr or days)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
Fig. 5.2 Hydrograph with multiple peaks
Thus, in actual streams gauged, the hydrograph may have a single peak or multiple
peaks according to the complexity of storms. For flood analysis and derivation of unit
hydrograph, a single peaked hydrograph is preferred. A complex hydrograph, however, can be
resolved into simple hydrographs by drawing hypothetical recession lines as shown in Fig. 5.2.
It has been found from many hydrographs that the ground water depletion curves for a
given drainage basin are nearly the same and hence it is termed as the normal ground water
depletion curve. It has been found that such curves, or at least their segments, follow a simple
inverse exponential function of the elapsed time of the form.
Q
t
= Q
0
K
r
t
...(5.1)
where Q
0
= discharge at start of period
Q
t
= discharge at end of time t
K
r
= recession constant
As Q
t
is the derivations of storage with respect to time,
d S
t
= Q
t
dt
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 119
HYDROGRAPHS 119
S
t
=
z
Q
t
dt =
z
(Q
0
K
r
1
) dt
S
t
=
Q
K
t
e r
log
3
z
a
x
=
a
a
x
log
...(5.2)
Hence, the discharge at any time is proportional to the water remaining in storage i.e.,
Q
Q
t
0
=
S
S
t
0
...(5.2 a)
Taking logarithms on both sides of Eq. (5.1)
log Q
t
= log Q
0
t log K
r
which is in the straight line form y = mx + c with y = log Q
t
, x = t, and m = log K
r
. The value
of K
r
can be determined by plotting the recession data i.e., Q
t
vs. t on a semi-log paper, taking
care to select periods of little or no direct runoff; see Example 17.3.
Time t (hr or days) (natural scale)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
L
o
g
s
c
a
l
e
a. Semi-log plot of continuous
discharge hydrograph
Master
depletion curve
(semi-log plot)
a
b
c
e
g
d
f
b. Semi-log plot of
master depletion curve
Lower ends of curves
are tangential to a
common line
i
j
h
Time t (hr or days) (natural scale)
L
o
g
Q
Master depletion
curve (natural scale)
c. Master depletion
curve drawn to linear scale
Time t (hr or days)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
a
b
c
d
e
f
g
h
i
Fig. 5.3 Composite ground water depletion curve
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 120
120 HYDROLOGY
If a continuous stream flow record is available for a number of years, the hydrograph
can be plotted on a semi-log paper, i.e., log Q vs. t, Fig. 5.3. Starting with the lowest recession
flow line, a line is drawn tangential to the lower portion on a tracing paper. This tangent line
is progressively extended by moving the tracing-paper towards the origin with the abscissae
coincident, such that the line is tangential to the lower portion of the successive depletion
curves of increasing magnitude. This common line is the log plot of the master depletion curve,
which is then converted to linear vertical scale and is called the composite ground water depletion
curve.
A composite ground water depletion curve can be constructed from the recession graphs
resulting from a number of storms. The various segments of the recession graphs are shifted
with respect to the time axis until they appear to match and then, an average or composite
curve is drawn through them as shown in Fig. 5.4.
20
18
16
14
12
10
8
6
4
2
0
3 6 9 12 15 18 21 24 27
Time t (hr or days)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
1
0
o
r
1
0
0
)
Master depletion curve
Storm recession curves
moved (to match) w.r.t.
time-axis
Fig. 5.4 Composite depletion curve
5.2 SEPARATION OF STREAMFLOW COMPONENTS
Barnes (1940) proposed that the stream flow components may be separated by plotting the
hydrograph on a semi-log paper (Fig. 5.5). The tail end of the hydrograph plots as a straight
line, i.e., ground water recession (CD). If this straight line plot is extended backwards up to the
point E directly under the inflection point I and line BE drawn, the area under BEC represents
the ground water contribution to the stream flow. If the ordinates of this area are deducted
from the ordinates of the total hydrograph and replotted, the hydrograph of surface runoff and
interflow (subsurface flow) is obtained, which plots as a straight line (HG) at the tail end. By
extending this line backwards up to the point L directly under I and drawing the line FL, the
area under FLG gives the interflow component. By deducting the ordinates of this from the
ordinates of the hydrograph of surface runoff and interflow, the hydrograph of surface runoff
is replotted whose tail end again, may plot as a straight line representing the surface recession
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 121
HYDROGRAPHS 121
or channel storage. The slopes of the straight line plots at the tail ends of the separated
hydrographs give the respective recession constants.
Example 5.1 The mean daily streamflow data from a drainage basin is given below. It is known
that the recession limb of the discharge hydrograph has components of channel storage, interflow
and base flow. Find the values of the recession coefficients for each of the three components.
Date Mean daily discharge Date Mean daily discharge
(cumec) (cumec)
1978, Oct. 4 278 1978, Oct. 14 179
5 265 15 167
6 5350 16 157
7 8150 17 147
8 6580 18 139
9 1540 19 131
10 505 20 123
11 280 21 117
12 219 22 111
13 195 23 105
24 100
Also determine
(a) ground water storage on October 14, 1978.
(b) ground water storage and stream flow on October 30, 1978, assuming no rainfall
during the period.
Solution The discharge hydrograph is drawn on a semi-log paper and the flow components
are separated by the method proposed by Bernes as shown in Fig. 5.5. The recession coeffi-
cients (K
r
) for the three components of base flow (ground water contribution), interflow and
channel storage are computed as 1.059, 2.104 and 4.645, respectively.
(a) Ground water storage (S
0
) on October 14, 1978 when the ground water depletion
starts.
S
0
=
Q
k
e r
0
log
=
179 86400 m /day
log 1.06/day
3
e
= 2.75 10
8
m
3
(b) Stream flow on October 30, 1978, i.e., after 16 days
Q
t
= Q
0
K
r
t
Q
16 days
= 179 (1.06)
16
= 71.6 cumec
Ground water storage (S
t
) on October 30, 1978 can be determined from
Q
Q
t
0
=
S
S
t
0
or S
t
= S
0

Q
Q
t
0
S
16 days
= (2.75 10
8
)
716
179
.
= 1.10 10
8
m
3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 122
122 HYDROLOGY
10000
8
6
4
3
2
1000
8
6
4
3
2
100
8
6
5
4
3
2
10
8
6
5
4
3
2
1
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Interflow
Surface
recession
Surface
runoff
Semi-log paper
Total runoff hydrograph
(of stream flow)
Q = Q K
t o r
t
Log Q = log Q t log K
t o r

y c m + x (Slope m is ve)
m = log K , K = daily depletion factor
or recession constant
r r
Surface runoff plus interflow
Ground water recession
m = = 0.026
= log K
r
log 330/100
20 days
K = 1.06 days
r
1
K
=
2
.
1
0
d
a
y
s
r

1
K
=
4
.
6
4
d
a
y
s
r

1
H
G M
Date Days Natural scale
F
E
L
C
I
B
A
L
o
g
-
s
c
a
l
e
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
D
Fig. 5.5 Separation of streamflow components (after Barnes, 1940)
5.3 HYDROGRAPH SEPARATION
For the derivation of unit hydrograph, the base flow has to be separated from the total runoff
hydrograph (i.e., from the hydrograph of the gauged stream flow). Some of the well-known
base flow separation procedures are given below, Fig. 5.6.
(i) Simply by drawing a line AC tangential to both the limbs at their lower portion.
This method is very simple but is approximate and can be used only for preliminary estimates.
(ii) Extending the recession curve existing prior to the occurrence of the storm up to the
point D directly under the peak of the hydrograph and then drawing a straight line DE, where
E is a point on the hydrograph N days after the peak, and N (in days) is given by
N = 0.83 A
0.2
...(5.3)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 123
HYDROGRAPHS 123
Peak
B
N days
I
Direct
surface
runoff
4
2
3
2
1
Time t (hr or days)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
N (days) = 0.84 A (empirical)
A = Drainage area (km
0.2
2
)
Four separation procedures
E (N days after peak)
G
C
Recession
Ground water contribution
to stream (base flow) D
F
Point of
rise
A
Fig. 5.6 Hydrograph separation
where A = area of the drainage basin, km
2
and the size of the areas of the drainage basin as a
guide for the values of N are given below :
Area of drainage basin (km
2
) 250 1250 5000 12500 25000
Time after peak, N (days) 2 3 4 5 6
(iii) Simply by drawing a straight line AE, from the point of rise to the point E, on the
hydrograph, N days after the peak.
(iv) Construct a line AFG by projecting backwards the ground water recession curve
after the storm, to a point F directly under the inflection point of the falling limb and sketch an
arbitrary rising line from the point of rise of the hydrograph to connect with the projected base
flow recession. This type of separation is preferred where the ground water storage is rela-
tively large and reaches the stream fairly repidly, as in lime-stone terrains.
Many a time a straight line AE meets the requirements for practical purposes. Location
of the point E is where the slope of the recession curve changes abruptly, and as a rough guide
E is N days after the peak. In all the above four separation procedures, the area below the line
constructed represents the base flow, i.e., the ground water contribution to stream flow. Any
further refinement in the base flow separation procedure may not be needed, since the base
flow forms a very insignificant part of high floods. In fact, very often, a constant value of base
flow is assumed.
In Fig. 5.7, ADE is the assumed base flow. Actually, when the water level in the stream
rises due to floods, the stream feeds the ground water and the permeable boundaries (called
bank storage, Fig. 5.8) and this is termed as negative base flow. But actually the variation in
base flow may be much less than indicated in Fig. 5.7 depending on the permeability of the
boundaries and the gradient of the phreatic surface. The resulting variation will be a slight dip
from the extrapolated depletion curve, followed by a gradual rise to a higher level than the
initial value as the flood recedes as shown in Fig. 5.9.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 124
124 HYDROLOGY
Time t (hr)
Negative base flow
(bank storage)
Increase in base flow
after flood
Discharge
hydrograph
Surface
runoff
Recession
curves
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
A
E
D
Fig. 5.7 Negative baseflow
G
W
T
Ground water flow
Ground water flow
(during low water period)
Permeable
banks of stream
GWT
Bank storage
High water level
Low water level
Fig. 5.8 Bank storage
Discharge
hydrograph
Direct
surface
runoff
Separation line
Extrapolated
depletion curve
Base flow
Recession
curve
Time t (hr)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Fig. 5.9 Actual baseflow variation
5.4 UNIT HYDROGRAPH
The unit hydrograph is defined as the hydrograph of storm runoff resulting from an isolated
rainfall of some unit duration occurring uniformly over the entire area of the catchment, pro-
duces a unit volume (i.e., 1 cm) of runoff.
Derivation of the unit hydrographs. The following steps are adopted to derive a unit
hydrogaph from an observed flood hydrograph (Fig. 5.10).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 125
HYDROGRAPHS 125
46 45 45 45 46 48 50 53 54 57 60 55 51 50
300
250
200
150
100
50
0
2 5 8 11 14 17 20 23 2 5 8 11 14 17 20 23
10
8
6
4
2
0
0 3 6 9 12 15 18 21 24 27 30 33
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
Rainfall, P
P = 26.6 cm = Runoff
net
c.g. of P
net
f-index
D
i
s
c
h
a
r
g
e
(
S
t
r
e
a
m
f
l
o
w
)
Q
(
c
u
m
e
c
)
Time t (min)
t = 3 hr = Effective duration of storm
r
t = 10 hr
p
1
2
Basin lag
peak flow
N = 0.84 (40) = 1 day (too long)
0.2
3
4
P = =
net
SQ .t
A
d
986 (3 60 60)
40 10
6
m
m
3
2
= 0.266 m
or 26.6 cm ... 1
Total
run off
hydrograph
S S Q = DRO = 986 cumec
d
P = P Losses
= (i )t ... 2
net
S f
t = duration of rain (min)
for which i > f
P from 1 & 2
should balance
DSR stops recession
net
Direct surface
runoff = 26.6 cm
120 = TRO = Q
75 = DRO = TRO BFO
= Q = 120 45
d Point of
rise
D.SR
starts Arbitrary line of separation
47
BFO
Base flow
131970 231970
D
i
s
c
h
a
r
g
e

c
u
m
e
c
Hours from beginning of runoff
Runoff duration T = 32 hr
P =
1 cm
net
t
2
r
t
r
7
5
/
2
6
.
6
=
2
.
8
2
t
p
Date and time hr
Peak of UG
Unit
hydrograph
Area under
curve = 1 cm
of runoff
2.82 = UGO =
DRO
P
net
TRO BFO = DRO
= UGO (for which P = 1 cm)
net
DRO
P
net
t = 3 hr = unit hydrograph duration
r
Time to peak = t +
p
Recession
t
r
2
Fig. 5.10 Derivation of a unit hydrograph (Example 5.1)
(i) Select from the records isolated (single-peaked) intense storms, which occurring
uniformly over the catchment have produced flood hydrographs with appreciable runoff (>1
cm, say, 8 to 16 cm). The unit period selected should be such that the excess rainfall (i.e., P
net
)
occurs fairly uniformly over the entire drainage basin. Larger unit periods are required for
larger basins. The unit periods may be in the range of 15-30% of the peak time period, i.e., the
time from the beginning of surface runoff to the peak, and the typical unit periods may be 3, 6,
8, 12 hours. (The time of concentration may be a little longer than the peak time).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 126
126 HYDROLOGY
The unit storm is a storm of such duration that the period of surface runoff is not much
less for any other storm of shorter duration.
(ii) Select a flood hydrograph, which has resulted from a unit storm chosen in item (i)
above.
(iii) Separate the base flow from the total runoff (by the well-known base flow separa-
tion procedures).
(iv) From the ordinates of the total runoff hydrograph (at regular time intervals) deduct
the corresponding ordinates of base flow, to obtain the ordinates of direct runoff.
(v) Divide the volume of direct runoff by the area of the drainage basin to obtain the net
precipitation depth over the basin.
(vi) Divide each of the ordinates of direct runoff by the net precipitation depth to obtain
the ordinates of the unit hydrograph.
(vii) Plot the ordinates of the unit hydrograph against time since the beginning of direct
runoff. This will give the unit hydrograph for the basin, for the duration of the unit storm
(producing the flood hydrograph) selected in item (i) above.
In unit hydrograph derivation, such storms should be selected for which reliable rain-
fall and runoff data are available. The net rain graph (hyetograph of excess rain) should be
determined by deducting the storm loss and adjusting such that the total volume of net storm
rain is equal to the total volume of direct surface runoff. The unit hydrograph derived, which,
when applied to the known net rain data, should yield the known direct runoff hydrograph.
The steps given above for the derivation of unit hydrograph can be formulated as fol-
lows (exemplified in Fig. 5.10).
P
net
= P Losses ...(5.4)
or P
net
=
Q t
A
d
, Q
d
= DRO ...(5.4 a)
TROBFO = DRO ...(5.4 b)

DRO
P
net
= UGO ...(5.4 c)
where P = total rainfall
P
net
= net precipitation (from hyetograph) or direct runoff as equivalent depth
over the basin.
Losses = due to infiltration (F
p
), etc.
A = area of the drainage basin
Q
d
, DRO = direct runoff ordinate
TRO = total runoff ordinate
t = time interval between successive direct runoff ordinates
BFO = base flow ordinate
Elements of unit hydrograph. The various elements of a unit hydrograph are shown in
Fig. 5.11.
Base width (T)The period of direct surface runoff (due to a unit storm) of the unit
hydrograph is called the time base or the base width.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 127
HYDROGRAPHS 127
Unit
period
t
r
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
i = cm/hr
1
t
r
P = 1 cm = i t
net r
Recession time T
r
Lag time
t
p
t
r
/2
Q
p
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Peak of UG, Q cumec
p
Time to peak
Concen-
tration time
t
c
I, inflection
point
Unit
hydrograph
Channel
storage
Area under
curve
1 cm of
runoff over
catchment
area A

Time base T (hr)


(Runoff duration)
Time t (hr)
Fig. 5.11 Elements of unit hydrograph
Unit stormThe strom of unit duration (i.e., duration of the unit hydrograph) regard-
less of its intensity is called unit storm.
Unit periodThe time duration of the unit storm (i.e., the duration of the unit
hydrograph) is called unit period.
Lag time (t
p
)The time from the centre of a unit storm to the peak discharge of the
corresponding unit hydrograph is called lag time.
Recession time (T
r
)The duration of the direct surface runoff after the end of the excess
or net rainfall, is called recession time in hydrograph analysis.
Propositions of the Unit Hydrograph
The following are the basic propositions of the unit hydrograph:
(i) Same runoff duration. For all unit storms of different intensities, the period of sur-
face runoff (i.e., time base, base width or base period) is approximately the same, although
they produce different runoff volumes (Fig. 5.12 (a)).
(ii) Proportional ordinates. For unit storms of different intensities, the ordinates of the
hydrograph at any given time, are in the same proportion as the rainfall intensities
(Fig. 5.12 (a)).
(iii) Principle of superposition. If there is a continuous storm and/or isolated storms of
uniform intensity net rain, they may be divided into unit storms and hydrographs of runoff for
each storm obtained, and the ordinates added with the appropriate time lag to get the com-
bined hydrograph (Fig. 5.12 (b)).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 128
128 HYDROLOGY
I
n
t
e
n
s
i
t
y
(
c
m
/
h
r
)
xi
i
i = , xi = cm/hr
1
t
r
x
t
r
t = 1 cm
r
1
t
r
t = x cm
r
x
t
r
P
net
x cm
1 cm

t
r
x Q
p
Q
p
x Q
y
Q
y
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Time base T
Time t (hr)
Run off
= x cm
Q
Run off
= 1 cm
p
Q
y
t
1
t
peak
Hydrograph (produces
x cm of runoff)
Peaks occur
at same time
Proportional ordinates
t hr UG (1-cm runoff)
r
Same time base T
(a) Proportional ordinates and same time base
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
t = 2 t
R r
x cm
2
y cm
t
r
t
r
Continuous storm split into two unit storms
3
z cm
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Combined hydrograph (obtained
by summing the ordinates of the
three component hydrographs: 1, 2 & 3)
Hydrographs
corresponding
to storm 1, 2 & 3
UGO z
3
2
1
UGO y
UGO x
t hr UGO
r
Time t (hr)
(b) Principle of superposition
1
t
r
P due to 3-storms
unit period t hr
net
r
Fig. 5.12 Propositions of unit hydrograph
(iv) Same distribution percentages. If the total period of surface runoff (i.e., time base or
base width) is divided into equal time intervals the percentage of surface runoff that occurs
during each of these periods will be same for all unit storms of different intensities (Fig. 5.13).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 129
HYDROGRAPHS 129
1 2 3 4 5 6 7 8 9 10
12
11
10
9
8
7
6
5
4
3
2
1
0
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
P
net
y cm = i = cm/hr
y
t
r
x cm = i = cm/hr
x
t
r
1 cm = i = cm/hr
1
t
r
S Midordinates of unit periods
= 0.5 + 2.0 + 4.7 + 7.1 + 5.6
+ 3.5 + 2.5 + 1.6 + 0.9 + 0.3
= 28.7 units
% of runoff in unit period 1
= 100 = 1.74 2 (rounded)
and like that.

0.5
28.7
UGO y = y cm runoff hydrograph
UGO x = x cm runoff hydrograph
Distribution percentages
(Same for all units storms)
UGO = 1 cm runoff unit hydrograph
Area under UG = Area under bar graph
Mid-ordinates of unit periods
Bernards distribution graph
If t = 4 hr, T = 40 hr
r
1%
3%
5.5%
9%
12%
19.5%
25%
Unit period
25% runoff
occurs
in unit
period 4
4
25%
3
16%
19.5
%
5
16%
+
+ ve & ve
areas
should
balance
7.1 units
5.6
3.5
2.5
1.6
0.9
UGO
(1 cm)
4.7
2.0 units
7%
2%
0.5
Time base T divided into 10 unit periods
Time t (hr)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
(
s
a
y
,
1
0
c
u
m
e
c
u
n
i
t
s
)

Fig. 5.13 Distribution percentages same for all unit storms


Limitation of the Unit Hydrograph. Certain limitations are inherent in the unit
hydrograph theory. The runoff hydrograph reflects the combined effects of rainfall factors,
loss factors and physiographic factors. The design storm continuing for several unit periods
may not have the same areal distribution for each time increment. Storm movements also
affect the proportions of the unit hydrograph if the basin is large. Hence, the unit hydrograph
can not be applied for basins larger than 5000 km
2
. For basins larger than 5000 km
2
, unit
hydrographs for the principal sub-areas or sub-basins are developed and the hydrographs of
runoff determined for each sub-area. These hydrographs are then combined, through flood
routing procedure, to get the resulting hydrograph at the required section.
Derivation of Unit Hydrograph
Example 5.1 (a) The runoff data at a stream gauging station for a flood are given below. The
drainage area is 40 km
2
. The duration of rainfall is 3 hours. Derive the 3-hour unit hydrograph
for the basin and plot the same.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 130
130 HYDROLOGY
Date Time Discharge Remarks
(hr) (cumec)
1-3-1970 2 50
5 47
8 75
11 120
14 225
17 290 Peak
20 270
23 145
2-3-1970 2 110
5 90
8 80
11 70
14 60
17 55
20 51
23 50
State the peak of the unit hydrograph you derive.
Solution See Table 5.1.
5.5 UNIT HYDROGRAPH FROM COMPLEX STORMS
Unit hydrographs from complex storms, involving varying intensities of rain can be obtained
by considering the complex storm as successive unit storms of different intensities and the
runoff hydrograph (due to complex storm) as the result of superposition of the successive
storm hydrographs. The ordinates of each storm hydrograph are obtained as the storm inten-
sity times the corresponding ordinate of the unit hydrograph as shown in Fig. 5.14. The unit
hydrograph ordinates u
1
, u
2
, ... are thus obtained by writing a series of equations for each of
the ordinates Q
1
, Q
2
, .... of the runoff hydrograph (due to complex storm) and successively
solving them. In Fig. 5.14,
Q
1
= xu
1
u
1
= ?
Q
2
= xu
2
+ yu
1
u
2
= ?
Q
3
= xu
3
+ yu
2
+ zu
1
u
3
= ?
and so on. Thus, the t
r
hour unit graph ordinates can be determined. Although the method is
straight forward, errors will creep in due to the assumptions on the intensity and duration of
rainfall and deduction of an assumed base flow; many trials are required to get a reasonable
unit graph.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 131
HYDROGRAPHS 131
Table 5.1 Derivation of the 3-hour unit hydrograph. Example 5.1
Date Time TRO
1
BFO
2
DRO
2
UGO
4
Time
5
(hr) (cumec) (cumec) (3)(4) (5) P
net
from begin-
(cumec) (cumec) ning of
surface run
off (hr)
1 2 3 4 5 6 7
1-3-1970 2 50 50
5 47 47 0 0 0
8 75 46 29 1.09 3
11 120 45 75 2.82 6
14 225 45 180 6.77 9
17 290 45 245 9.23 12
20 270 46 224 8.44 15
23 145 48 97 3.65 18
2-3-1970 2 110 50 60 2.26 21
5 90 53 37 1.39 24
8 80 54 26 0.98 27
11 70 57 13 0.49 30
14 60 60 0 0 33
17 55 55
20 51 51
23 50 50
DRO = 986 cumec
1
TROTotal runoff ordinate = gauged discharge of stream
2
BFOBase flow ordiante read from graph separation line shown in Fig. 5.10 (a). N = 0.83 A
0.2
= 0.89(40)
0.2
= 1.73 days = 1.73 24 = 41.4 hr from peak, which is seen not applicable here; hence an
arbitrary separation line is sketched.
3
DRODirect runoff ordinate = TROB.F.O.
4
UGOUnit hydrograph ordinate
=
DRO
P
P
DRO t
A
net
net
3
6 2
986(3 60 60)m
40 10 m
;
.
= =

= 0.266 m = 26.6 cm
5
Time from beginning of direct surface runoff is at 5 hr on 1-3-1970, which is reckoned 0 hr for
unit hydrograph. The time base for unit hydrograph is 33 hours.
The 3-hour unit hydrogryph is plotted in Fig. 5.10 (b) to a different vertical scale and its peak is
9.23 cumec.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 132
132 HYDROLOGY
P due to 3-storms
nets
z cm
x cm
y cm
t
r
t
r
t
r
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Q
3
Q
2
Q
4
Q
5
Q
1
y
u
1
z
u
1
y
u
2
z
u
2
Q
6
Q
7
0
0
x
u
1
y
u
3
z
u
3
u
2 u
1 u
3
x
u
2
t hr
UGO
r
x
u
4
u
4
u
s y u
5
z u
4
Time t (hr)
0
0
z u
5
Observed hydrograph
Q = x u
1 1
2 2 1
3 3 2 1
Q = x u + y u
Q = x u + y u + z u , etc
Successively solve
for u , u , u , etc.
which give t hr UGO
1 2 3
r
y
u
4
x u
5
UG
x u
3
Fig. 5.14 Derivation of unit hydrograph from multi-period storms
Example 5.2 The stream flows due to three successive storms of 2.9, 4.9 and 3.9 cm of 6 hours
duration each on a basin are given below. The area of the basin is 118.8 km
2
. Assuming a
constant base flow of 20 cumec, derive a 6-hour unit hydrograph for the basin. An average
storm loss of 0.15 cm/hr can be assumed.
Time (hr): 0 3 6 9 12 15 18 21 24 27 30 33
Flow (cumec): 20 50 92 140 199 202 204 144 84.5 45.5 29 20
Solution Let the 6-hour unit hydrograph ordinates be u
0
, u
1
, u
2
, u
3
, u
4
, ...., u
7
at 0, 3, 6, 12, ....,
21 hours, respectively. The direct runoff ordinates due to the three successive storms (of 6
hours duration each) are obtained by deducting the base of flow of 20 cumec from the stream-
flows at the corresponding time intervals as shown in Table 5.2. The net storm rains are ob-
tained by deducting the average storm loss as
0-6 hr: x = 2.9 0.15 6 = 2 cm
6-12 hr: y = 4.9 0.15 6 = 4 cm
12-18 hr: z = 3.9 0.15 6 = 3 cm
The equations can be easily arrived by entering in a tabular column and successively
solving them. The 6-hr unit hydrograph ordinates are obtained in the last column; of course
the ordinates are at 3-hr intervals since the streamflows are recorded at 3-hr intervals. The
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 133
HYDROGRAPHS 133
D
R
O

d
u
e

t
o
*
*
E
q
u
a
t
i
o
n
T
i
m
e
U
G
O
*
1
s
t

s
t
o
r
m
2
n
d

s
t
o
r
m
3
r
d

s
t
o
r
m
T
o
t
a
l

D
R
O

=

T
R
O


B
F
O
S
o
l
u
t
i
o
n
(
h
r
)
U
G
O


x
U
G
O


y
U
G
O


z
6
-
h
r

U
G
O
0
u
0

=

0
0

0

=

2
0


2
0
u
0

=

0
3
u
1
2
u
1

2
u
1

=

5
0


2
0
u
1

=

1
5
6
u
2
2
u
2
0

2
u
2

=

9
2


2
0
u
2

=

3
6
9
u
3
2
u
3
4
u
1

2
u
3

+

4
u
1

=

1
4
0


2
0
u
3

=

3
0
1
2
u
4
2
u
4
4
u
2
0
2
u
4

+

4
u
2

+

0

=

1
9
9


2
0
u
4

=

1
7
.
5
1
5
u
5
2
u
5
4
u
3
3
u
1
2
u
5

+

4
u
3

+

3
u
1

=

2
0
2


2
0
u
5

=

8
.
5
1
8
u
6
2
u
6
4
u
4
3
u
2
2
u
6

+

4
u
4

+

2
u
2

=

2
0
4


2
0
u
6

=

3
2
1
u
7
2
u
7
4
u
5
3
n
3
2
u
7

+

4
u
5

+

3
u
3

=

1
4
4


2
0
u
7

=

0
2
4
4
u
6
3
u
4
4
u
6

+

3
u
4

=

8
4
.
5


2
0


u

=

1
1
0
2
7
4
u
7
3
u
5
4
u
7

+

3
u
5

=

4
5
.
5


2
0



u
5

=

8
.
5
c
h
e
c
k

f
o
r
3
0
3
u
6
3
u
6

=

2
9


2
0



u
6

=

3
U
G
O

d
e
r
i
v
e
d
3
3
3
u
7
3
u
7

=

2
0


2
0



u
7

=

0
a
b
o
v
e
*
E
x
c
e
p
t

t
h
e

f
i
r
s
t

c
o
l
u
m
n
,

a
l
l

o
t
h
e
r

c
o
l
u
m
n
s

a
r
e

i
n

c
u
m
e
c
.
*
*
x

=

2

c
m
,

y

=

4

c
m
,

z

=

3

c
m
U V | W |
T
a
b
l
e

5
.
2

D
e
r
i
v
a
t
i
o
n

o
f

a

6
-
h
o
u
r

u
n
i
t

h
y
d
r
o
g
r
a
p
h

f
r
o
m

a

c
o
m
p
l
e
x

s
t
o
r
m
,

E
x
a
m
p
l
e

5
.
2
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 134
134 HYDROLOGY
last four equations in the table serve to check some of the UGOs derived. Another check for
the UGOs derived is that the area under the UG should give a runoff volume equivalent to
1 cm, i.e.,
u t
A
= 1 cm, in consistent units
u = sum of the UGOs = 110 cumec

110 3 60 60
118 8 10
6
( )
.

= 0.01 m, or 1 cm
Hence, the UGOs derived are correct and is plotted in Fig. 5.15 (b).
The UGOs can also be derived by the method of least squares (Snyder, 1955) by writing
the direct runoff ordinate (Q) as
Q = a + b
1
x
1
+ b
2
x
2
+ b
3
x
3
+ ... + b
i
x
i
...(5.5)
where a = 0 theoretically, b
i
= u
i
, and x
1
, x
2
, x
3
,... are the rainfall excesses (P
net
) in successive
periods. In the least square technique, data from a number of flood events, for which values of
Q
i
and x
i
are established, are used to develop a set of average values of b
i
(= u
i
) and the unit
hydrograph derived. The method is more elegant but laborious.
200 220
180 200
160 180
140 160
120 140
100 120
80 100
60 80
40 60
20 40
0 20
0
0 3 6 9 12 15 18 21 24 27 30 33
Time t (hr)
Constant base flow = 20 cumec
S
t
r
e
a
m
f
l
o
w
Q
(
c
u
m
e
c
)
S
u
r
f
a
c
e
r
u
n
o
f
f
Q
(
c
u
m
e
c
)
a. observed
hydrograph due
to 18-hr storm
(us = 6-hr UGO)
3
u
2
2 cm
3 cm
4 cm
6 hr 6 hr 6 hr
P due to 3 storms
net
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
2
u
1
2
u
3
2
u
4
2
u
2
UGO 2
2
u
5
2 u
6
4
u
5
4
u
5
3
u
5
3
u
6
3
u
4
3
u
3
4
u
4
UGO 3
UGO 4
4
u
3
4
u
2
4
u
1
3
u
1
Fig. 5.15 (a) Derivation of 6-hr UG from 18-hr complex storm hydrograph (Example 5.2)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 135
HYDROGRAPHS 135
40
35
30
25
20
15
10
5
0
0 3 6 9 12 15 18 21
6-hr UG derived
(u's = UGO)
u
1
u
2
Time t (hr)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
u
3
u
4
u
s
u
6
Fig. 5.15 (b) 6-hr unit hydrograph (derived) (Example 5.2)
Matrix method for unit hydrograph derivation from complex storm
In matrix notation
PU = Q
where P =
p
p p
p p p
p p p
p p
p
1
2 1
3 2 1
3 2 1
3 2
3
0 0 0 0 0
0 0 0 0
0 0 0
0 0 0
0 0 0 0
0 0 0 0 0
L
N
M
M
M
M
M
M
O
Q
P
P
P
P
P
P
U =
u
u
u
u
1
2
3
4
0
0
L
N
M
M
M
M
M
M
O
Q
P
P
P
P
P
P
Q =
q
q
q
q
q
q
1
2
3
4
5
6
L
N
M
M
M
M
M
M
O
Q
P
P
P
P
P
P
By deducting base flow from the stream flow hydrograph Q is known, and with the
known rainfall excess P, the unit hydrograph U can be computed as
U = P
1
Q
The inverse for the precipitation matrix (P
1
) exists only if it is a square matrix with a
non-vanishing determinant. However, by the use of the transpose of the precipitation matrix,
(P
T
), a square matrix is obtained as
P
T
PU = P
T
Q
and the unit hydrograph matrix is obtained as
U = (P
T
P)
1
P
T
Q
Usually, the solution of the unit hydrograph matrix is performed on a digital computer
(Newton, 1967). Most computer installations have packaged programmes to work with large
systems and for determining the inverse and transpose of matrices.
Also, the number of streamflow hydrograph ordinates (n) is given by
n = j + i 1
where j = number of UGO
i = number of periods of rainfall
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 136
136 HYDROLOGY
In Example 5.2, n = 12 ordinates at 3-hr interval (DRO of the first and last being zero) ;
i = 6 periods of 3-hr interval (= 3 2), then
n = j + i 1; 12 = j + 6 1
j = 7 UGO
Thus, the unit hydrograph consists of 7 ordinates at 3-hr intervals (of course, u
0
= 0, and
u
7
= 0).
As an assignment, the student is advised first to become well versed with the matrix
algebra and then apply the matrix method to derive the 6-hr UGO at 3-hr interval from the
streamflow data given in Example 5.2.
Average Unit Hydrograph. It is better if several unit graphs are derived for different
isolated (single peaked) uniform intensity storms. If the durations of storms are different, the
unit hydrographs may be altered to the same duration (sect .... or art .....). From several unit
hydrographs for the same duration, so obtained, an average unit hydrograph can be sketched
by computing the average of the peak flows and times to peak and sketching a median line,
(Fig. 5.16), so that the area under the graph is equal to a runoff volume of 1 cm.
1
2
3
P = 1 cm
net
t
r
Qp
3
Qp
2
Qp
1
Qp
Average peak given by:
Q =
p
Q + Q + Q
3
p1 p2 p3
t =
peak
t + t + t
3
1 2 3
Median line sketched so that area
under curve = 1 cm runoff, gives t -hr
average unit hydrograph
r
1 , 2 & 3 : t -hr 's
obtained from different
duration storms
r
UG
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
t
1
t
peak
t
2
t
3
Time base T of ave. UG
Time t (hr)
Fig. 5.16 Average unit hydrograph
Alteration of Unit Hydrograph Duration. It becomes necessary, in computation of
flood hydrographs, that the duration of the unit graph available should be altered to suit the
duration of the design storm (to be used for obtaining the flood hydrograph). Two cases arise:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-1.PM5 137
HYDROGRAPHS 137
Case (i) Changing a Short Duration Unit Hydrograph to Longer Duration. If the desired
long duration of the unit graph is an even multiple of the short, say a 3-hour unit graph is
given and a 6-hour unit graph is required. Assume two consecutive unit storms, producing a
net rain of 1 cm each. Draw the two unit hydrographs, the second unit graph being lagged by
3 hours. Draw now the combined hydrograph by superposition. This combined hydrograph
will now produce 2 cm in 6 hours. To obtain the 6-hour unit graph divide the ordinates of the
combined hydrograph by 2, Fig. 5.17. It can be observed that this 6-hour unit graph derived
has a longer time base by 3 hours than the 3-hour unit graph, because of a lower intensity
storm for a longer time.
Example 5.3 The following are the ordinates of a 3-hour unit hydrgraph. Derive the ordinates
of a 6-hour unit hydrograph and plot the same.
Time (hr) 3-hr UGO Time (hr) 3-hr UGO
(cumec) (cumec)
0 0 15 9.4
3 1.5 18 4.6
6 4.5 21 2.3
9 8.6 24 0.8
12 12.0
Solution
Table 5.3 Derivation of the 6-hour unit hydrograph. (Example 5.3)
3-hr 3-hr Total 6-hr
Time UGO UGO (2) + (3) UGO
(hr) (cumec) (logged) (cumec) (4) 2
(cumec) (cumec)
1 2 3 4 5
0 0 0 0
3 1.5 0 1.5 0.7
6 4.5 1.5 6.0 3.0
9 8.6 4.5 13.1 6.5
12 12.0 8.6 20.6 10.3
15 9.4 12.0 21.4 10.7
18 4.6 9.4 14.0 7.0
21 2.3 4.6 6.9 3.4
24 0.8 2.3 3.1 1.5
27 0.8 0.8 0.4
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 138
138 HYDROLOGY
The 6-hour unit graph derived as above is shown in Fig. 5.17.
27 24 21 18 15 12 9 6 3 0
22
20
18
16
14
12
10
8
6
4
2
0
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
1 cm
1 cm, P
net
2 unit storms
3 hr 3 hr
Combined hydrograph
(2 cm in 6 hr)
3-hr UG's lagged by 3 hr
6-hr UG (1 cm in 6 hr)
(comb. hyd. ord. 2)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Time t (hr)
Fig. 5.17 Changing a short duration UG to a long multiple duration
Case (ii) Changing a Long Duration Unit Hydrograph to a Shorter Duration by S-curve
Technique
5.6 S-CURVE METHOD
S-curve or the summation curve is the hydrograph of direct surface discharge that
would result from a continuous succession of unit storms producing 1 cm in t
r
hr (Fig. 5.18). If
the time base of the unit hydrograph is T hr, it reaches constant outflow (Q
e
) at T hr, since 1 cm
of net rain on the catchment is being supplied and removed every t
r
hour and only T/t
r
unit
graphs are necessary to produce an S-curve and develop constant outflow given by,
Q
e
=
278 . A
t
r
...(5.6)
where Q
e
= constant outflow (cumec)
t
r
= duration of the unit graph (hr)
A = area of the basin (km
2
)
Given a t
r
-hour unit graph, to derive a t
r
-hour unit graph (t
r


t
r
)Shift the S-curve by
the required duration t
r
along the time axis. The graphical difference between the ordinates of
the two S-curves, i.e., the shaded area in Fig. 5.18 represents the runoff due to t
r
hours rain at
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 139
HYDROGRAPHS 139
an intensity of 1/t
r
cm/hr, i.e., runoff of t
r
/t
r
cm in t
r
hours. To obtain a runoff of 1 cm in t
r

hours (i.e., t
r
-hour UG), multiply the ordinates of the S-curve difference by t
r
/t
r
. This tech-
nique may be used to alter the duration of the given unit hydrograph to a shorter or longer
duration. The longer duration need not necessarily be a multiple of short.
24 22 20 18 16 14 12 10 8
480
440
400
360
320
280
240
200
160
120
80
40
0
Successive unit storms of P = 1 cm
net
1 cm 1 cm 1 cm 1 cm 1 cm 1 cm
t
r
t
r
t
r
t
r
t
r
t
r
I
n
t
e
n
s
i
t
y
=
(
c
m
/
h
r
)
i
1 t
r
S-curve
hydrograph
Lagged
S-curve
(lagged by
t hr)
r
To obtain t hr UG
multiply the S-curve
difference by t /t
r
r r

Constant outflow
Q =
e
2.78 A(km )
t (hr)
2
r
Cumec
Unit hydrographs in
succession produce
constant outflow, Q cumec
e
t
r
cm
in t hr
r

B
A
t hr UG
r
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Time t (hr)
0 6
t
r

Lagged
Area
s-curve
difference
=
1
t
r
2 4
Fig. 5.18 Changing the duration of UG by S-curve technique (Example 5.5)
Example 5.4 The ordinates of a 4-hour unit hydrograph for a particular basin are given be-
low. Derive the ordinates of (i) the S-curve hydrograph, and (ii) the 2-hour unit hydrograph,
and plot them, area of the basin is 630 km
2
.
Time Discharge Time Discharge
(hr) (cumec) (hr) (cumec)
0 0 14 70
2 25 16 30
4 100 18 20
6 160 20 6
8 190 22 1.5
10 170 24 0
12 110
Solution See Table 5.4
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 140
140 HYDROLOGY
T
a
b
l
e

5
.
4

D
e
r
i
v
a
t
i
o
n

o
f

t
h
e

S
-
c
u
r
v
e

a
n
d

2
-
h
o
u
r

u
n
i
t

h
y
d
r
o
g
r
a
p
h
s
.

(
E
x
a
m
p
l
e

5
.
4
)
*
S
l
i
g
h
t

a
d
j
u
s
t
m
e
n
t

i
s

r
e
q
u
i
r
e
d

t
o

t
h
e

t
a
i
l

o
f

t
h
e

2
-
h
o
u
r

u
n
i
t

h
y
d
r
o
g
r
a
p
h
.
C
o
l

(
5
)
:

l
a
g
g
e
d

S
-
c
u
r
v
e

i
s

t
h
e

s
a
m
e

a
s

c
o
l

(
4
)

b
u
t

l
a
g
g
e
d

b
y

t
r


=

2

h
r
.
C
o
l

(
7
)
:

c
o
l

(
6
)


t
t
r
r

,

t
r

=

4

h
r
.

t
r


=

2

h
r
.
C
o
l

(
3
)
:

N
o
.

o
f

u
n
i
t

s
t
o
r
m
s

i
n

s
u
c
c
e
s
s
i
o
n

=

T
/
t
r

=

2
4
/
4

=

6
,

t
o

p
r
o
d
u
c
e

a

c
o
n
s
t
a
n
t

o
u
t
f
l
o
w
.
Q
e

=

2
7
8
.

A
t
r

=

2
7
8
6
3
0
4
.


=

4
3
7

c
u
m
e
c
,

w
h
i
c
h

a
g
r
e
e
s

v
e
r
y

w
e
l
l

w
i
t
h

t
h
e

t
a
b
u
l
a
t
e
d

S
-
c
u
r
v
e

t
e
r
m
i
n
a
l

v
a
l
u
e

o
f

4
3
6
.

T
h
e

S
-
c
u
r
v
e
a
d
d
i
t
i
o
n
s

c
a
n

b
e

w
r
i
t
t
e
n

i
n

o
n
e

c
o
l
u
m
n
,

w
i
t
h
o
u
t

h
a
v
i
n
g

t
o

w
r
i
t
e

i
n

5

c
o
l
u
m
n
s

s
u
c
c
e
s
s
i
v
e
l
y

l
a
g
g
e
d

b
y

4

h
o
u
r
s

(
=

t
r
)
,

a
s

i
s

i
l
l
u
s
t
r
a
t
e
d

i
n

t
h
e
e
x
a
m
p
l
e

5
.
5
.
P
l
o
t

c
o
l

(
4
)

v
e
r
s
u
s

c
o
l

(
1
)

t
o

g
e
t

t
h
e

S
-
c
u
r
v
e

h
y
d
r
o
g
r
a
p
h
,

a
n
d

c
o
l

(
7
)

v
e
r
s
u
s

c
o
l

(
1
)

t
o

g
e
t


t
h
e

2
-
h
o
u
r

u
n
i
t

h
y
d
r
o
g
r
a
p
h
,

a
s

s
h
o
w
n

i
n
F
i
g
.
5
.
1
9
.
T
i
m
e
4
-
h
r

U
G
O
S
-
c
u
r
v
e

a
d
d
i
t
i
o
n
s
S
-
c
u
r
v
e
l
a
g
g
e
d
S
-
c
u
r
v
e
2
-
h
r

U
G
O
(
h
r
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
o
r
d
i
n
a
t
e
s
S
-
c
u
r
v
e
d
i
f
f
e
r
e
n
c
e
(
6
)


4
/
3
(
u
n
i
t

s
t
o
r
m
s

a
f
t
e
r

e
v
e
r
y

4

h
r

=

t
r
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
2
)

+

(
3
)
(
4
)


(
5
)
1
2
3
4
5
6
7
0
0

0
0
2
2
5

2
5
0
2
5
5
0
4
1
0
0
0

1
0
0
2
5
7
5
1
5
0
6
1
6
0
2
5

1
8
5
1
0
0
8
5
1
7
0
8
1
9
0
1
0
0
0

2
9
0
1
8
5
1
0
5
2
1
0
1
0
1
7
0
1
6
0
2
5

3
3
5
2
9
0
6
5
1
3
0
1
2
1
1
0
1
9
0
1
0
0
0

4
0
0
3
5
5
4
5
9
0
1
4
7
0
1
7
0
1
6
0
2
5

4
2
5
4
0
0
2
5
5
0
1
6
3
0
1
1
0
1
9
0
1
0
0
0

4
3
0
4
2
5
5
1
0
*
1
8
2
0
7
0
1
7
0
1
6
0
2
5

4
4
5
4
3
0
1
5
3
0
2
0
6
3
0
1
1
0
1
9
0
1
0
0
0
4
3
6
4
4
5


1
8
*
2
2
1
.
5
2
0
7
0
1
7
0
1
6
0
2
5
4
4
6
.
5
4
3
6
1
0
.
5
2
1
2
4
0
6
3
0
1
1
0
1
9
0
1
0
0
4
3
6
4
4
6
.
6


1
0
.
5


2
1
*
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 141
HYDROGRAPHS 141
Example 5.5 The ordinates of a 4-hour unit hydrograph for a particular basin are given be-
low. Determine the ordinates of the S-curve hydrograph and therefrom the ordinates of the 6-
hour unit hydrograph.
Time 4-hr UGO Time 4-hr UGO
(hr) (cumec) (hr) (cumec)
0 0 12 110
2 25 14 70
4 100 16 30
6 160 18 20
8 190 20 6
10 170 22 1.5
24 0
Solution See Table 5.5.
Table 5.5 Derivation of the 6hour UG for the basin (Example 5.5)
Time 4-hour S-curve
1
S-curve lagged
2
S-curve 6-hr
(hr) UGO additions ordinates C-curve difference UGO
(cumec) (cumec) (cumec) (cumec) (cumec) (cumec)
(2) + (3) (4) (5) (6) 4/6
1 2 3 4 5 6 7
0 0 0 0 0
2 25 25 25 16.7
4 100 + 0 100 100 66.7
6 160 + 25 185 0 185 123.3
8 190 100 290 25 265 176.7
10 170 185 355 100 255 170.0
12 110 290 400 185 215 143.3
14 70 355 425 290 135 90.0
16 30 400 430 355 75 50.0
18 20 425 445 400 45 30.0
20 6 430 436 425 11 7.3
22 1.5 445 446.6 430 16.5 11.0
24 0 436 436 445 9 6.0
1Start the operation shown with 0 cumec after t
r
= 4 hr.
2Lag the Scurve ordinates by t
r
= 6 hr.
Plot col (4) vs. col (1) to get S-curve hydrograph and col (7) vs. col (1) to get 6-hr unit hydrograph
as shown in Fig. 5.19.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 142
142 HYDROLOGY
5.7 BERNARDS DISTRIBUTION GRAPH
The distribution graph, introduced by Bernard in 1935, shows the percentages of total unit
hydrograph, which occur during successive, arbitrarily chosen, uniform time increments,
Fig. 5.20. It is an important concept of the unit hydrograph theory that all unit storms, regard-
less of their intensity, produce nearly identical distribution graphs.
The procedure of deriving the distribution graph is first to separate the base flow from
the total runoff; the surface runoff obtained is divided into convenient time units, and the
average rate of surface runoff during each interval is determined.
If the rainfall-runoff data for a short duration fairly uniform storm is known, the dura-
tion of net rainfall is taken as the unit period and the distribution percentages are computed
directly. But if there are multiple storms of different intensities producing different net rains
during successive unit periods, a trial and error procedure of applying the distribution per-
centages is followed, till the direct surface runoff during successive time intervals corresponds
to the computed values. Once a distribution graph is derived for a drainage basin, any ex-
pected volume of surface runoff from the basin can be converted into a discharge hydrograph.
By drawing a smooth curve along the steps of the distribution graph to give equal areas, a unit
hydrograph may be obtained as shown in Fig. 5.20.
Example 5.6 Analysis of the runoff records for a one day unit storm over a basin yields the
following data:
480
440
400
360
320
280
240
200
160
120
80
40
0
26 24 22 20 18 16 14 12 10 8 6 4 2 0
S-curve hydrograph
S-curve lagged by t = 2 hr
r
S-curve difference
area
6-hr (Derived)-Example 5.5 UG
2-hr (Derived)-Example 5.4 UG
4-hr UG (given)
A B = 65 m /s
3 A
B
i
t
r
= t
r
cm in hr t
r
Q =
e
To get 1 cm in t , i.e., t -hr UG:
r r
Multiply the S-curve difference by
t
t
r
r
t
t
r
r

i.e.,
= 1 cm in t -hr
r

(A B)
t
t
r
r

4
2
= 2 hr lag
t
r
Time t (hr)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
2.78 (630)
4
= 437 cumec
= 65
= 130 cumec

t
t
r
r

Fig. 5.19 Derivation of 2-hr & 6-hr UG from a 4-hr UG (Example 5.4 & 5.5)
Total stream flow at concentration point on successive days are 19.6, 62.4, 151.3, 133.0,
89.5, 63.1, 43.5, 28.6, and 19.6 cumec.
Estimated base flow during the corresponding period on successive days are 19.6, 22.4,
25.3, 28.0, 28.0, 27.5, 25.6, 22.5 and 19.6 cumec.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 143
HYDROGRAPHS 143
Determine the distribution graph percentages.
On the same basin (area = 2850 km
2
) there was rainfall of 7 cm/day on July 15 and 10
cm/day on July 18 of a certain year. Assuming an average storm loss of 2 cm/day, estimate the
value of peak surface runoff in cumec and the date of its occurrence.
Table 5.6 Derivation of distribution percentages
Day since DRO on Percentage
beginning of mid-day of Remarks
direct runoff (cumec) DRO
1 2 3 4
1 18 4.5 =
18
402
100
2 96 24
3 120 30
4 82 20
5 47 12
6 25 6
7 12 3
8 2 0.5
8 equal time DRO = 402 Total = 100.0
(i.e., a day) intervals
1 2 3 4 5 6 7 8 9 10
Time base T divided into 10 unit periods
Unit periods
+ve & ve areas should balance
(area under bar graph = area under UG)
t h
r r
UG
Distribution percentages
same for all unit storms
Distribution graph
Distribution % 100 =
0
i
0 S
i
Unit period
25%
19.5%
16 %
+ 12%
9%
5.5%
3%
1%
0
9
0
8
0
7
0
6
0
5
0
4
0
3
0
2
0
1
7%
2%
%
o
f
t
o
t
a
l
d
i
s
c
h
a
r
g
e
t
r
P = x cm
net
P =1cm
net
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
0
10

Fig. 5.20 Distribution graph (after Bernard, 1935)


DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 144
144 HYDROLOGY
Solution The total runoff hydrograph and estimated base flow are drawn in Fig. 5.21 and the
direct runoff ordiantes on successive mid-days are determined as DRO = TRO BFO and the
percentages of direct runoff on successive days computed in Table 5.6. Column (3) gives the distri-
bution percentages, and the derived distribution graph for 1-day unit storms is shown in Fig. 5.22.
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
1 2 3 4 5 6 7 8 9 10 11 0
Time t (days)
Base flow
Direct surface
runoff
47
25
12
2
82
120
96
18
Streamflow hydrograph
Mid-ordinates (cumec)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
160
Fig. 5.21 Stream flow hydrograph (Example 5.6)
36
32
28
24
20
16
12
8
4
0 1 2 3 4 5 6 7 8
Distribution
percentages
30
20
24
12
6
3
0.5
4.5
%
o
f
t
o
t
a
l
s
u
r
f
a
c
e
r
u
n
o
f
f
1-day unit periods
Fig. 5.22 Derived distribution graph (Example 5.6)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 145
HYDROGRAPHS 145
12 10 11 8 7 6 5 4 3 2 1 0 9
1000
800
600
400
200
0
Runoff hydrograph
due to 2-storms on
July 15 & 18
892 cumec (peak flood)
D
i
r
e
c
t
s
u
r
f
a
c
e
r
u
n
o
f
f
(
c
u
m
e
c
)
July 15 16 17 18 19 20 21 22 23 24 25 26
Days (date)
Fig. 5.23 Runoff Hydrograph (Example 5.6)
Applying the distribution percentages computed in col. (3) above the direct surface dis-
charge on successive days due to the two storms (lagged by 3 days) is computed in Table 5.7
1 cm/day =
1
100
2850 10
24 60 60
6



= 330 cumec
The peak surface runoff is 892 cumec and occurs on July 20 of the year. The flood
hydrograph is shown in Fig. 5.23.
Example 5.7 Analysis of rainfall and runoff records for a certain storm over a basin (of area
3210 km
2
) gave the following data:
Rainfall for successive 2 hr periods: 2.5, 6.5 and 4.5 cm/hr.
An average loss of 1.5 cm/hr can be assumed.
Direct surface discharge at the concentration point for successive 2-hr periods: 446, 4015,
1382, 25000, 20520, 10260, 4900 and 1338 cumec.
Derive the unit hydrograph in the form of distribution percentages on the basis 2-hr unit
periods.
Solution The rainfall may be considered for three unit periods of 2 hr each, then from Fig. 5.24,
T
DSR
= t
R
+ T
r
...(5.7)
T = t
r
+ T
r
...(5.7 a)
T = t
r
+ T
DSR
t
R
= 2 + 8 2 3 2 ...(5.7 b)
T = 12 hr
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 146
146 HYDROLOGY
U
n
i
t

p
e
r
i
o
d
s

(
d
a
y
)
1
2
3
4
5
6
7
8
9
1
0
1
1
T
o
t
a
l

r
a
i
n
f
a
l
l

(
c
m
)

7
1
0
L
o
s
s

o
f

r
a
i
n

(
c
m
)

2
2
N
e
t

r
a
i
n

(
c
m
)

5
8

(
=

1
3

c
m
)
U
n
i
t

d
i
s
t
r
i
b
u
t
i
o
n
D
i
s
t
r
i
b
u
t
i
o
n

(
c
m
/
d
a
y
)
P
e
r
i
o
d
s

P
e
r
c
e
n
t
a
g
e
s
1
4
.
5
0
.
2
2
5
0
.
3
6
2
2
4
1
.
2
0
1
.
9
2
3
3
0
1
.
5
0
2
.
4
0
4
2
0
1
.
0
0
1
.
6
0
5
1
2
0
.
6
0
0
.
9
6
6
6
0
.
3
0
0
.
4
8
7
3
0
.
1
5
0
.
2
4
8
0
.
5
0
.
0
2
5
0
.
0
4
T
o
t
a
l

(
c
m
/
d
a
y
)
:
0
.
2
2
5
1
.
2
0
1
.
5
0
1
.
3
6
2
.
5
2
2
.
7
0
1
.
7
5
0
.
9
8
5
0
.
4
8
0
.
2
4
0
.
0
4

=

1
3

c
m
(
c
h
e
c
k
)


3
3
0

=

c
u
m
e
c
:
7
4
3
9
6
4
9
5
4
5
0
8
3
3
8
9
2
5
7
8
3
2
5
1
5
8
7
9
1
3

(
0
.
2
2
5


3
3
0
)
=

7
4

c
u
m
e
c
)
D
a
t
e
:

J
u
l
y
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
T
a
b
l
e

5
.
7

A
p
p
l
i
c
a
t
i
o
n

o
f

d
i
s
t
r
i
b
u
t
i
o
n

p
e
r
c
e
n
t
a
g
e
s

t
o

c
o
m
p
u
t
e

t
h
e

d
i
r
e
c
t

s
u
r
f
a
c
e

d
i
s
c
h
a
r
g
e

(
E
x
a
m
p
l
e

5
.
6
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 147
HYDROGRAPHS 147
The base width is 12 hr or 6 unit periods. As a first trial, try a set of six distribution
percentages of 10, 20, 40, 15, 10, 5 which total 100%. The direct surface discharge can be
converted into cm/hr as
1 cm/hr =
1
100
3210 10
60 60
6

= 8920 cumec
1 cm/hr
5 cm/hr
3 cm/hr
Loss rate 1.5 cm/hr
P
net
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
t
R
T
r
t
r
t
r
t
r
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
T
T
T
T
DSR
Time t (hr)
3
2
1
Base time, T = t + T
= t + T t
r r
r DSR R
Combined hydrograph due
to 3-unit stroms 1,2 & 3
Hydrograph due to 3-unit storms
Duration of direct surface
runoff, T = t + T
DSR R r
t = unit duration
t = rainfall duration
T = recession time
r
R
r
Fig. 5.24 Combined hydrograph (Example 5.7)
Gauged
Computed (1 trial)
st
T = 8 2
= 16 hr
DSR
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
0 1 2 3 4 5 6 7 8
2-hr-unit periods
D
i
r
e
c
t
s
u
r
f
a
c
e
r
u
n
o
f
f
(
c
m
/
h
r
)
D
i
s
t
r
i
b
u
t
i
o
n
%
(
1
t
r
i
a
l
,
2
t
r
i
a
l
)
s
t
n
d
10, 5 1
2 20, 20
3 40, 40
4 15, 20
5 10, 10
6 5, 5
Fig. 5.25 Derivation of distribution percentages (Example 5.7)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 148
148 HYDROLOGY
2
-
h
r
-
u
n
i
t

p
e
r
i
o
d
s
1
2
3
4
5
6
7
8
R
a
i
n
f
a
l
l

r
a
t
e

(
c
m
/
h
r
)

2
.
5
6
.
5
4
.
5
L
o
s
s

r
a
t
e

(
c
m
/
h
r
)

1
.
5
1
.
5
1
.
5
N
e
t

r
a
i
n

(
c
m
/
h
r
)

1
5
3


(
=

9


2

c
m
)
U
n
i
t

d
i
s
t
r
i
b
u
t
i
o
n
D
i
s
t
r
i
b
u
t
i
o
n

(
c
m
/
h
r
)
P
e
r
i
o
d
s

P
e
r
c
e
n
t
a
g
e
1




1
0

(
5
)
(
0
.
0
5
)
(
0
.
2
5
)
(
0
.
1
5
)
0
.
1
0
0
.
5
0
0
.
3
0
2
2
0
0
.
2
0
1
.
0
0
0
.
6
0
3
4
0
0
.
4
0
2
.
0
0
1
.
2
0
4
1
5

(
2
0
)
(
0
.
2
0
)
(
1
.
0
0
)
(
0
.
6
0
)
0
.
1
5
0
.
7
5
0
.
4
5
5
1
0
0
.
1
0
0
.
5
0
0
.
3
0
6
5
0
.
0
5
0
.
2
5
0
.
1
5
T
o
t
a
l

1
0
0

(
1
0
0
)

c
m
/
h
r
0
.
1
0
0
.
7
0
1
.
7
0
2
.
7
5
2
.
0
5
1
.
0
0
0
.
5
5
0
.
1
5
(
=

9


2

c
m

c
h
e
c
k
)
(
0
.
0
5
)
(
0
.
4
5
)
(
1
.
5
5
)
(
2
.
8
0
)
(
2
.
3
0
)
(
1
.
1
5
)
c
u
m
e
c
4
4
6
4
0
1
5
1
3
8
2
2
5
0
0
0
2
0
5
2
0
1
0
2
6
0
4
9
0
0
1
3
3
8
(
4
4
6
/
8
9
2
0

=

0
.
0
5

c
m
/
h
r
)
N
o
t
e

F
i
g
u
r
e
s

i
n

b
r
a
c
k
e
t
s

i
n
d
i
c
a
t
e

t
h
e

a
d
j
u
s
t
e
d

v
a
l
u
e
s

i
n

t
h
e

s
e
c
o
n
d

t
r
i
a
l
.
T
a
b
l
e

5
.
8

D
e
r
i
v
a
t
i
o
n

o
f

d
i
s
t
r
i
b
u
t
i
o
n

p
e
r
c
e
n
t
a
g
e
s

b
y

t
r
i
a
l
s

(
E
x
a
m
p
l
e

5
.
7
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 149
HYDROGRAPHS 149
and the direct surface runoff for successive 2-hr periods are 0.05, 0.45, 1.55, 2.80, 2.30, 1.15,
0.55, and 0.15 cm/hr. The first trial hydrograph computed in Table 5.8 is shown by dashed
lines in Fig. 5.25 for comparison and selection of the distribution percentages for the second
trial. The first percentage affects the first 3 unit periods, the second percentage affects the
2nd, 3rd and 4th unit periods and like that. Since the first trial hydrograph gives higher val-
ues (than gauged) for the first three unit periods, a lower percentage of 5 (instead of 10%) is
tried. Similarly, the other percentages are adjusted till the computed discharge values agree
with the gauged values. Thus, the second trial distribution percentages are 5, 20, 40, 20, 10, 5
which total 100 and are final and the distribution graph thus derived is shown in Fig. 5.26. In
most cases, more trials are required to obtain the desired degree of accuracy.
Also see AppendixG.
20 20
10
5 5
40
60
50
40
30
20
10
0
%
o
f
t
o
t
a
l
d
i
r
e
c
t
s
u
r
f
a
c
e
r
u
n
o
f
f
00 1 2 3 4 5 6
2-hr unit periods
Fig. 5.26 Derived distribution graph (Example 5.7)
5.8 INSTANTANEOUS UNIT HYDROGRAPH
The difficulty of using a unit hydrograph of a known duration has been obviated by the devel-
opment of the instantaneous unit hydrograph (IUH). The IUH is a hydrograph of runoff re-
sulting from the instantaneous application of 1 cm net rain on the drainage basin. The IUH in
conjunction with the design storm can be used to obtain the design flood by using a convolution
integral. The IUH was first proposed by Clark in 1945. The IUH can be developed either
directly from the observed data or by adopting conceptual models [see Chapter16 & 17 for
Methods of Determining IUH].
5.9 SYNTHETIC UNIT HYDROGRAPHS
In India, only a small number of streams are gauged (i.e., streamflows due to single and mul-
tiple storms, are measured). There are many drainage basins (catchments) for which no
streamflow records are available and unit hydrographs may be required for such basins. In
such cases, hydrographs may be synthesised directly from other catchments, which are
hydrologically and meteorologically homogeneous, or indirectly from other catchments through
the application of empirical relationship. Methods for synthesising hydrographs for ungauged
areas have been developed from time to time by Bernard, Clark, McCarthy and Snyder. The
best known approach is due to Snyder (1938). Snyder analysed a large number of hydrographs
from drainage basins in the Applachian Mountain region in USA ranging in the area from 25
to 25000 km
2
and selected the three parameters for the development of unit hydrograph, namely,
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 150
150 HYDROLOGY
base width (T), peak discharge (Q
p
) and lag time (basin lag, t
p
), Fig. 5.27, and proposed the
following empirical formulae for the three parameters:
Lag time, t
p
= C
t
(L L
ca
)
0.3
...(5.8)
standard duration of net rain, t
r
=
t
p
55 .
...(5.9)
1/3 2/3
W
50
Area under
curve = 1 cm
runoff volume
0
.
5
Q
p
0
.
7
5
Q
p
W
75
1/3
2/3
Synthetic
unit hydrograph
W = hr
50
5.6
q
p
1.08
W = hr
75
3.21
q
p
1.08
q = cumec/km
p
2
Q
A
p
t = , Snyder
r
t
5.5
p
t = C (L.L )
p t ca
0.3
Q = C
p p
A
t
p
T 5 t hr
p
Peak flow
Basin lag
t
p
t
r
2
Q
p
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Base time T (days or hr)
Time t (hr)
I
n
t
e
n
s
i
t
y
i
=
(
c
m
/
h
r
)
1 t
r
Unit duration
P = 1 cm
net
Centre of P
net
t
r
Fig. 5.27 Synthetic unit hydrograph parameters
For this standard duration of net rain,
peak flow, Q
p
= C
p

A
t
p
...(5.10)
time base in days, T = 3 + 3
t
p
24
F
H
G
I
K
J
...(5.11)
peak flow per km
2
of basin, q
p
=
Q
t
p
p
...(5.12)
Snyder proposed subsequently an expression to allow for some variation in the basin lag
with variation in the net rain duration, i.e., if the actual duration of the storm is not equal to t
r
given by Eq. (5.9) but is t
r
, then
t
pr
= t
p
+
t t
r r
4
...(5.13)
where t
pr
= basin lag for a storm duration of t
r
, and t
pr
is used instead of t
p
in Eqs. (5.10),
(5.11) and (5.12).
In the above equations,
t
p
= lag time (basin lag), hr
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 151
HYDROGRAPHS 151
C
t
, C
p
= empirical constants (C
t
0.2 to 2.2, C
p
2 to 6.5, the values depending on the
basin characteristics and units)
A = area of the catchment (km
2
)
L = length of the longest water course, i.e., of the mainstream from the gauging
station (outlet or measuring point) to its upstream boundary limit of the basin,
(km) (Fig. 5.28)
L
ca
= length along the main stream from the gauging station (outlet) to a point on the
stream opposite the areal centre of gravity (centroid) of the basin
L km
ca
L km
Centroid of
basin
M
a
in
w
a
te
r
c
o
u
r
s
e
Upstream
boundary
of river
Point in
river opp.
centroid
Tributary
Area of
basin A, km
2
River
Basin boundary
Basin lag (Snyder)
t = c (L.L )
p t ca
0.3
Basin slope, S
Gauging
Stn.
(outlet)
T
r
i
b
u
t
a
r
y
Taylor & Schwarz
C = , a = Constant
t
a
s
Linsley, et al.
t = c ( )
p t
n L.L
S
ca
Fig. 5.28 Basin characteristics (Snyder)
Snyder considered that the shape of the unit hydrograph is likely to be affected by the
basin characteristics like area, topography, shape of the slope, drainage density and channel
storage. He dealt with the size and shape of basin by measuring the length of the mainstream
channel. The coefficient C
t
reflects the size, shape and slope of the basin.
Linsley, Kohler and Paulhus gave an expression for the lag time in terms of the basin
characteristics (see Fig. 5.31) as
t
p
= C
t

LL
S
ca
n
F
H
G
I
K
J ...(5.14)
where S = basin slope, and the values of n and C
t
, when L, L
ca
were measured in miles are
n = 0.38
C
t
= 1.2, for mountainous region
= 0.72, for foot hill areas
= 0.35, for valley areas
Taylor and Scwarz found from an analysis of 20 drainage basins of size 50-4000 km
2
in
the north and middle Atlantic States in USA that (when L and L
ca
were measured in miles)
C
t
=
0 6 .
S
...(5.15)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 152
152 HYDROLOGY
Time base in hr, T = 5 t
t
pr
r
+
F
H
G
I
K
J
2
...(5.16)
i.e., T = 5 t
peak
...(5.16 a)
The usual procedure for developing a synthetic unit hydrograph for a basin for which
the streamflow records are not available is to collect the data for the basin like A, L, L
ca
and to
get the coefficients, C
t
and C
p
from adjacent basins whose streams are gauged and which are
hydrometeorologically homogeneous. From these the three parameters, i.e., the time to peak,
the peakflow and the time base are determined from the Snyders empirical equations, and the
unit hydrograph can be sketched so that the area under the curve is equal to a runoff volume
of 1 cm. Empirical formulae have been developed by the US Army Corps of Engineers (1959)
for the widths of W
50
and W
75
of the hydrograph in hours at 50% and 75% height of the peak
flow ordinate, respectively, (see Fig. 5.29) as
W
50
=
5 6
1 08
.
.
q
p
...(5.17)
W
75
=
3 21
175
1 08
50
.
.
.
q
W
p
= ...(5.18)
C
u
r
v
e
W
5
0
C
u
r
v
e
W
7
5
B

B
A
10
8
6
4
3
2
1
0.8
0.6
0.4
0.3
0.2
0.10
0.08
0.07
0.2 0.3 0.4 0.8 1 2 3 4 6 8 10 20 30 40 60 80 100
P
e
a
k
d
i
s
c
h
a
r
g
e
q
,
(
c
u
m
e
c
/
k
m
p
2
)
Widths W & W (hr)
50 75
A

Fig. 5.29 Widths W


50
and W
75
for synthetic UG (US Army, 1959)
A still better shape of the unit hydrograph can be sketched with these widths (Fig. 5.27).
The base time T given by Eq. (5.11) gives a minimum of 3 days even for very small basins and
is in much excess of delay attributable to channel storage. In such cases, the author feels T
given by Eq. (5.16 a) may be adopted and the unit hydrograph sketched such that the area
under the curve gives a runoff volume of 1 cm.
Synthetic unit hydrographs for a few basins in India have been developed by CWPC.
Example 5.8 The following are the ordinates of the 9-hour unit hydrograph for the entire
catchment of the river Damodar up to Tenughat dam site:
Time (hr): 0 9 18 27 36 45 54 63 72 81 90
Discharge (cumec): 0 69 1000 210 118 74 46 26 13 4 0
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 153
HYDROGRAPHS 153
and the catchment characteristics are
A = 4480 km
2
, L = 318 km, L
ca
= 198 km
Derive a 3-hour unit hydrograph for the catchment area of river Damodar up to the head
of Tenughat reservoir, given the catchment characteristics as:
A = 3780 km
2
, L = 284 km, L
ca
= 184 km
Use Snyders approach with necessary modifications for the shape of the hydrograph.
Solution The 9-hr UG is plotted in Fig. 5.30 and from that t
p
= 13.5 hr
t
r
= 9 hr,
t
p
55
13 5
5 5 .
.
.
= = 2.46 hr t
r
of 9 hr
t
r
= 9 hr, t
pr
= 13.5 hr and t
p
has to be determined
t
pr
= t
p
+
t t
r r
4
13.5 = t
p
+
9 5 5
4
t
p
/ .
t
p
= 11.8 hr
t
p
= C
t
(LL
ca
)
0.3
11.8 = C
t
(318 198)
0.3
C
t
= 0.43
Peak flow, Q
p
= C
p

A
t
pr
1000 = C
p

4480
13 5 .
C
p
= 3.01, say, 3
The constants of C
t
= 0.43 and C
p
= 3 can now be applied for the catchment area up to
the head of the Tenughat reservoir, which is meteorologically and hydrologically similar.
t
p
= C
t
(LL
ca
)
0.3
= 0.43 (284 184)
0.3
= 11.24 hr

t
p
5 5
1124
55 .
.
.
= = 2.04 hr t
r
of 3 hr (duration of the required UG)
t
r
= 3 hr, t
r
= 2.04 hr and t
pr
has to be determined.
t
pr
= t
p
+
t t
r r
4
= 11.24 +
3 2 04
4
.
t
pr
= 11.48 hr, say, 11.5 hr
Peak flow Q
p
= C
p

A
t
pr
= 3
3780
115 .
= 987 cumec
Time to peak from the beginning of rising limb
t
peak
= t
pr
+
t
r
2
= 11.5 +
3
2
= 13 hr
Time base (Snyders) T (days) = 3 + 3
t
pr
24
F
H
G
I
K
J
= 3 + 3
11.5
24
F
H
G
I
K
J = 4.44 days or 106.5 hr
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 154
154 HYDROLOGY
This is too long a runoff duration and hence to be modified as
T(hr) = 5 t
peak
= 5 13 = 65 hr
To obtain the widths of the 3-hr UG at 50% and 75% of the peak ordinate :
q
p
=
Q
A
p
=
987
3780
= 0.261 cumec/km
2
W
50
=
5 6 5 6
0 261
08 08
.
( )
.
( . ) q
p
1. 1.
= = 23.8 hr
W
75
=
3 21 3 21
0 261
08 08
.
( )
.
( . ) q
p
1. 1.
=
= 13.6 hr =
238
175
.
.
These widths also seem to be too long and a 3-hr UG can now be sketched using the
parameters Q
p
= 987 cumec, t
peak
= 13 hr and T = 65 hr such that the area under the UG is
equal to a runoff volume of 1 cm, as shown in Fig. 5.30.
Synthetic unit hydrograph (3-hr)
(constants: C = 0.86, C = 3) for
basin upto head of reservoir
t p
Area under
UG = 1 cm
runoff volume
9-hr UG for the entire basin
upto Tenughat dam site
0 9 18 27 36 45 54 63 72 81 90
I
n
t
e
n
s
i
t
y
i
=
(
c
m
/
h
r
)
1 t
r
9 hr
P = 1 cm
net
13.5
4.5
hr
P
net
3 hr
1.5
hr
11.5
hr
987
cumec
peak
flow
W
75
1000 cumec peak
flow
W
50
1000
900
800
700
1000
600
500
400
300
200
100
0
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Base time T = 65 hr
Time t (hr)
Fig. 5.30 Synthetic unit hydrograph derived (Example 5.8)
5.10 TRANSPOSING UNIT HYDROGRAPHS
From Eq. (5.14)
t
p
= C
t

LL
S
ca
n
F
H
G
I
K
J
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-2.PM5 155
HYDROGRAPHS 155
log log log t C n
p t
!
!
= +
B
LL
S
ca
!
y = c + m x
Hence, a plot of t
p
vs.
LL
S
ca
on log-log paper from data from basins of similar hydrologic
characteristics gives a straight-line relationship (Fig. 5.31). The constant C
t
= t
p
when
LL
S
ca
= 1, and the slope of the straight line gives n. It may be observed that for basins having differ-
ent hydrologic characteristics the straight lines obtained are nearly parallel, i.e., the values of
C
t
varies depending upon the slope of the basin (as can be seen from Eq. 5.15) but the value of
n is almost same.
Log-log paper
Determination
of C & n from
data of gauged basins
t
for mountainous region
for foot hill areas
for valleys
1
2
3
t = c ( )
p t
n
LL
S
ca
n =
Slope
n
LL
S
ca
= 1
C = t , when
t p
S
lo
p
e
n
S
lo
p
e
n
1
2
3
100
80
60
40
30
20
10
8
6
5
4
3
2
1
2 3 4 6 8
10
20
100 1000
30 40 60 200 400
1000
1
10
100
100 10 1
km
2
B
a
s
i
n
l
a
g
t
(
h
r
)
p
LL
S
ca
Dy
Dx
Dy
Dx
Fig. 5.31 Basin lag vs. basin characteristics
From a plot of q
p
vs. t
p
, or from dimensionless hydrographs from gauged basins, the
peak flow and the shape of the unit hydrograph for ungauged basins can be estimated pro-
vided they are hydrometeorologically the same. The dimensionless unit hydrographs elimi-
nates the effect of basin size and much of the effect of basin shape. Hence, it is a useful means
for comparison of unit hydrographs of basins of different sizes and shapes or those resulting
from different storm patterns. It can be derived from a unit hydrograph by reducing its time
and discharge scales by dividing by t
p
and Q
p
, respectively. By averaging a number of
dimensionless unit hydrographs of drainage areas, a representative dimensionless graph can
be synthesized for a particular hydrological basin. A unit hydrograph for an ungauged basin,
hydrologically similar, can be obtained directly from this dimensionless graph by multiplying
by the appropriate values of t
p
(obtained from log-log plot) and Q
p
(from a plot of q
p
vs. t
p
).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 156
156 HYDROLOGY
Example 5.9 For the 9-hr UG given for the entire catchment of the river Damodar in Example
5.8, derive a dimensionless unit hydrograph.
Solution From example 5.8, t
p
= 11.8 hr, Q
p
= 1000 cumec, and hence the following computa-
tion can be made:
t
t
p
: 0 0.763 1.525 2.29 3.05 3.82 4.58 5.34 6.10 6.87 7.63
Q
Q
p
: 0 0.069 1 0.21 0.118 0.074 0.046 0.026 0.013 0.004 0
The dimensionless unit hydrograph is plotted as shown in Fig. 5.32.
Dimensionless
unit hydrograph
(t/t
p
)
0 1 2 3 4 5 6 7 8
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
(
Q
/
Q
p
)
Fig. 5.32 Dimensionless unit hydrograph
The US Soil Conservation Service (1971), using many hydrographs from drainage areas
of varying sizes and different geographical locations, has developed a dimensionless unit
hydrograph and has developed the following formulae.
t
peak
=
t t
c c
+ 0 133
7
.
1.
and q
p
=
0 208 . AQ
t
peak
where t
c
= time of concentration (hr)
t
peak
= time to peak discharge from beginning (hr)
=
t
t
r
p
2
+
, where t
p
is lag time
q
p
= peak discharge (cumec)
A = drainage area (km
2
)
Q = quantity of runoff, which is 1 mm for the unit hydrograph
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 157
HYDROGRAPHS 157
Most hydrologists assume t
c
as the time from the end of rainfall excess (P
net
) to the point
of inflection on the falling limb of the hydrograph; t
peak
can be determined from t
c
or lag time t
p
.
(basin lag) for the required t
r
-hr UG. From t
peak
and known drainage area q
p
can be determined.
Once t
peak
and q
p
are obtained, t vs. q can be computed from the data of the dimensionless unit
hydrograph and the UG can be sketched.
Example 5.9 (a) Construct a 4-hr UH for a drainage basin of 200 km
2
and lag time 10 hr by
the SCS method, given (pk = peak):
t
t
pk
: 0.5 1 2 3 4 5
Q
Q
p
: 0.4 1 0.32 0.075 0.018 0.004
Solution t
pk
=
t
r
2
+ t
p
=
4
2
+ 10 = 12 hr
(i) Q
p
=
5 36 5 36 200
12
. . A
t
pk
=

= 89.33 cumec, which occurs at
t
t
pk
= 1
or t = t
pk
= 12 hr
(ii) At
t
t
pk
= 0.5 or t = 0.5 12 = 6 hr,
Q
Q
p
= 0.4 or Q = 0.4 89.33 = 35.732 cumec
(iii) At
t
t
pk
= 2 or t = 2 12 = 24 hr,
Q
Q
p
= 0.32 or Q = 0.32 89.33 = 28.6 cumec
(iv) At
t
t
pk
= 3 or t = 3 12 = 36 hr,
Q
Q
p
= 0.075, or Q = 0.075 89.33 = 6.7 cumec
Time base T = 5 t
pk
= 5 12 = 60 hr; W
75
= W
50
/1.75
With this, a 4-hr UH can be sketched.
5.11 APPLICATION OF UNIT HYDROGRAPH
The application of unit hydrograph consists of two aspects:
(i) From a unit hydrograph of a known duration to obtain a unit hydrograph of the
desired duration, either by the S-curve method or by the principle of superposition.
(ii) From the unit hydrograph so derived, to obtain the flood hydrograph corresponding
to a single storm or multiple storms. For design purposes, a design storm is assumed, which
with the help of unit hydrograph, gives a design flood hydrograph.
While the first aspect is already given, the second aspect is illustrated in the following
example.
Example 5.10 The 3-hr unit hydrograph ordinates for a basin are given below. There
was a storm, which commenced on July 15 at 16.00 hr and continued up to 22.00 hr, which was
followed by another storm on July 16 at 4.00 hr which lasted up to 7.00 hr. It was noted from
the mass curves of self-recording raingauge that the amount of rainfall on July 15 was 5.75 cm
from 16.00 to 19.00 hr and 3.75 cm from 19.00 to 22.00 hr, and on July 16, 4.45 cm from 4.00 to
7.00 hr. Assuming an average loss of 0.25 cm/hr and 0.15 cm/hr for the two storms, respectively,
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 158
158 HYDROLOGY
and a constant base flow of 10 cumec, determine the stream flow hydrograph and state the time
of occurrence of peak flood.
Time (hr): 0 3 6 9 12 15 18 21 24 27
UGO (cumec): 0 1.5 4.5 8.6 12.0 9.4 4.6 2.3 0.8 0
Solution Since the duration of the UG is 3 hr, the 6-hr storm (16.00 to 22.00 hr) can be
considered as 2-unit storm producing a net rain of 5.75 0.25 3 = 5 cm in the first 3-hr period
and a net rain of 3.75 0.25 3 = 3 cm in the next 3-hr period. The unit hydrograph ordinates
are multiplied by the net rain of each period lagged by 3 hr. Similarly, another unit storm
lagged by 12 hr (4.00 to 7.00 hr next day) produces a net rain of 4.45 0.15 3 = 4 cm which is
multiplied by the UGO and written in col (5) (lagged by 12 hr from the beginning), Table 5.9.
The rainfall excesses due to the three storms are added up to get the total direct surface
discharge ordinates. To this, the base flow ordinates (BFO = 10 cumec, constant) are added to
get the total discharge ordinates (stream flow).
The flood hydrograph due to the 3 unit storms on the basin is obtained by plotting col (8)
vs. col. (1) (Fig. 5.33). This example illustrates the utility of the unit hydrograph in deriving
flood hydrographs due to a single storm or multiple storms occurring on the basin.
Date & Time t (hr)
Peak flood of 99 cumec
on July 16, 07.00 hr
Streamflow hydrograph
1 + 2 + 3 + B.F.
1
3
2
4 UGO
Base flow = 10 cumec (constant)
16 19 22 01 4 7 10 13 16 19 22 01 4 7
July 15 July 16 July 17
Loss
0.25 cm/hr
Loss
0.15 cm/hr
3 cm
4 cm
5 cm
3 hr 3 hr 3 hr
P
net
6-hr storm split into
2-unit periods
I
n
t
e
n
s
i
t
y
i
(
c
m
/
h
r
)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
100
90
80
70
60
50
40
100
30
20
10
0
3 UGO
5 UGO
0 0
Fig. 5.33 Application of UG to obtain stream flow hydrograph (Example 5.10)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 159
HYDROGRAPHS 159
D
R
O

d
u
e

t
o

r
a
i
n
f
a
l
l

e
x
c
e
s
s
T
o
t
a
l
T
i
m
e
U
G
O
*
I
I
I
I
I
I
D
R
O
B
F
O
T
R
O
R
e
m
a
r
k
s
(
h
r
)
U
G
O


5

c
m
U
G
O


3

c
m
U
G
O


4

c
m
(
3
)

+

(
4
)

+

(
5
)
(
c
o
n
s
t
a
n
t
)
(
6
)

+

(
7
)
1
2
3
4
5
6
7
8
0
0
0

0
1
0
1
0
.
0


J
u
l
y

1
5
,

1
6
.
0
0

h
r
3
1
.
5
7
.
5
0

7
.
5
1
0
1
7
.
5
c
o
m
m
e
n
c
e
m
e
n
t

o
f

f
l
o
o
d
6
4
.
5
2
2
.
5
4
.
5

2
7
.
0
1
0
3
7
.
0
9
8
.
6
4
3
.
0
1
3
.
5

5
6
.
5
1
0
6
6
.
5
1
2
1
2
.
0
6
0
.
0
2
5
.
8
0
8
5
.
8
1
0
9
5
.
8
1
5
9
.
4
4
7
.
0
3
6
.
0
6
8
9
.
0
1
0
9
9
.
0


P
e
a
k

f
l
o
o
d

o
n

J
u
l
y

1
6
,
1
8
4
.
6
2
3
.
0
2
8
.
2
1
8
6
9
.
2
1
0
7
9
.
2
0
7
.
0
0

h
r
2
1
2
.
3
1
1
.
5
1
3
.
8
3
4
.
4
5
9
.
7
1
0
6
9
.
7
2
4
0
.
8
4
.
0
6
.
9
4
8
5
8
.
9
1
0
6
8
.
9
2
7
0
0
2
.
4
3
7
.
6
4
0
.
0
1
0
5
0
.
0
3
0
0
1
8
.
4
1
8
.
4
1
0
2
8
.
4
3
3
9
.
2
9
.
2
1
0
1
9
.
2
3
6
3
.
2
3
.
2
1
0
1
3
.
2
3
9
0
0
1
0
1
0
.
0


F
l
o
o
d

s
u
b
s
i
d
e
s

o
n

J
u
l
y

1
7
0
7
.
0
0

h
r
*
A
l
l

c
o
l
u
m
n
s

a
r
e

i
n

c
u
m
e
c

u
n
i
t
s

e
x
c
e
p
t

c
o
l

(
1
)
.
T
a
b
l
e

5
.
9

D
e
r
i
v
a
t
i
o
n

o
f

t
h
e

f
l
o
o
d

h
y
d
r
o
g
r
a
p
h

d
u
e

t
o

m
u
l
t
i
p
l
e

s
t
o
r
m
s

(
E
x
a
m
p
l
e

5
.
1
0
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 160
160 HYDROLOGY
Example 5.11 The design storm of a water shed has the depths of rainfall of 4.9 and 3.9 cm for
the consecutive 1-hr periods. The 1-hr UG can be approximated by a triangle of base 6 hr with
a peak of 50 cumec occurring after 2 hr from the beginning. Compute the flood hydrograph
assuming an average loss rate of 9 mm/hr and constant base flow of 10 cumec. What is the area
of water shed and its coefficient of runoff?
Solution (i) The flood hydrograph due to the two consecutive hourly storms is computed in
Table 5.10, Fig. P5.34.
(ii) Area of water shedTo produce 1-cm net rain over the entire water shed (A km
2
).
Volume of water over basin = Area of UG (triangle)
(A 10
6
)
1
100
=
1
2
(6 60 60) 50
from which, A = 54 km
2
(iii) Coefficient of runoff C =
R
P
=
+
+
( . . ) ( . . )
. .
4 9 0 9 3 9 0 9
4 9 3 9
= 0.795
Table 5.10 Computation of design flood hydrograph (Example 5.11)
Time UGO* DRO due to rain- Total BF TRO Remarks
(hr) (cumec) fall excess (cumec) (cumec) (cumec) (cumec)
4.9 0.9 3.9 0.9
= 4 cm = 3 cm
1 0 0 0 10 10
2 25 100 0 100 10 110
3 50 200 75 275 10 285
4 37.5 150 150 300 10 310 Peak flood

5 25 100 112.5 212.5 10 222.5


6 12.5 50 75 125 10 135
7 0 0 37.5 37.5 10 47.5
8 0 0 10 10
*Ordinates by proportion in the triangular UG. Peak flood of 310 cumec, after 4 hr from the
commencement of the storm.
6 5 4 3 2 1 0
50
40
30
20
10
0
Peak
1-hr UG
Area 1 cm runoff
Q
(
c
u
m
e
c
)
Time (hr)
2
5
5
0
3
7
.
5
2
5
1
2
.
5
Fig. 5.34 (Example 5.11)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 161
HYDROGRAPHS 161
T
i
m
e
D
i
s
t
r
i
b
u
t
i
o
n
R
a
i
n
f
a
l
l
D
R
O

d
u
e

t
o

r
a
i
n
f
a
l
l
T
o
t
a
l

D
R
O
B
F
S
t
r
e
a
m

f
l
o
w
R
e
m
a
r
k
s
(
h
r
)
p
e
r
c
e
n
t
a
g
e
s
e
x
c
e
s
s

(
c
m
)
e
x
c
e
s
s

(
c
m
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
P
-
l
o
s
s

=

P
n
e
t
2
7
4
(
c
m
)
(
c
u
m
e
c
)
1
5
3
.
2


1
.
2

=

2
0
.
1
0

0
.
1
0
1
2
.
5
*
1
0
2
2
.
5


J
u
n
e

4
,

1
9
8
2
0
4
.
0
0

h
r
2
2
0
8
.
2


1
.
2

=

7
0
.
4
0
0
.
3
5

0
.
7
5
9
3
.
7
5
1
0
1
0
3
.
7
5
C
o
m
m
e
n
c
e
m
e
n
t
o
f

f
l
o
o
d
3
4
0
5
.
3


1
.
2

=

4
0
.
8
0
1
.
4
0
0
.
2
0
2
.
4
0
3
0
0
1
0
3
1
0
4
2
0
0
.
4
0
2
.
8
0
0
.
8
0
4
.
0
0
5
0
0
1
0
5
1
0

P
e
a
k

f
l
o
o
d

a
t
0
7
.
0
0

h
r

o
n
J
u
n
e

4
,

1
9
8
2
5
1
0
0
.
2
0
1
.
4
0
1
.
6
0
3
.
2
0
4
0
0
1
0
4
1
0
6
5
0
.
1
0
0
.
7
0
0
.
8
0
1
.
6
0
2
0
0
1
0
2
1
0
7

0
.
3
5
0
.
4
0
0
.
7
5
9
3
.
7
5
1
0
1
0
3
.
7
5
8

0
.
2
0
0
.
2
0
2
5
1
0
3
5
T
o
t
a
l
1
0
0
1
3
2
.
0
0
7
.
0
0
4
.
0
0
1
3
.
0
0
1
6
2
5
*

0
1
0
1
0
0
4
5
1
0
1
6
0
6
0
6
.
(
)


=

1
2
.
5

c
u
m
e
c
.
T
a
b
l
e

5
.
1
1

C
o
m
p
u
t
a
t
i
o
n

o
f

s
t
r
e
a
m

f
l
o
w

f
r
o
m

d
i
s
t
r
i
b
u
t
i
o
n

p
e
r
c
e
n
t
a
g
e
s
.

(
E
x
a
m
p
l
e

5
.
1
2
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 162
162 HYDROLOGY
Example 5.12 Storm rainfalls of 3.2, 8.2 and 5.2 cm occur during three successive hours over
an area of 45 km
2
. The storm loss rate is 1.2 cm/hr. The distribution percentages of successive
hours are 5, 20, 40, 20, 10 and 5. Determine the streamflows for successive hours assuming a
constant base flow of 10 cumec. State the peak flow and when it is expected; the precipitation
started at 04.00 hr, on June 4, 1982.
Solution The computation of stream flow hydrograph from the distribution percentages due
to net rainfall in three successive hours (i.e., from a complex storm) over an area of 45 km
2
is
made in Table 5.11.
Example 5.13 The successive three-hourly ordinates of a 6-hr UG for a particular basin are 0,
15, 36, 30, 17.5, 8.5, 3, 0 cumec, respectively. The flood peak observed due to a 6-hr storm was
150 cumec. Assuming a costant base flow of 6 cumec and an average storm loss of 6 mm/hr,
determine the depth of storm rainfall and the streamflow at successive 3 hr interval.
Solution DRO peak = Flood peak BF
= 150 6 = 144 cumec
P
net
=
DRO
UG
peak
peak
=
144
36
= 4 cm
Depth of storm rainfall,
P = P
net
+ losses = 4 + 0.6 6 = 7.6 cm.
DRO = UGO P
net
; DRO + BF = TRO
Hence, multiplying the given UGO by 4 cm and adding 6 cumec, the stream flow ordi-
nates at successive 3-hr intervals are: 6, 66, 150, 126, 76, 40, 18, 6 cumec, respectively.
OUZ V
I Match the items in A with items in B
A B
(i) Ground water depletion (a) Unit storm
(ii) Unit hydrograph (b) Flood hydrograph
(iii) TRO (c) Bernard
(iv) UGO (d) Synthetic unit hydrograph
(v) Unit duration (e) S-curve hydrograph
(vi) Change of unit duration (f) (TRO BFO) P
net
(vii) Distribution percentages (g) UGO P
net
+ BFO
(viii) Design storm (h) 1 cm of runoff
(ix) Ungauged stream (i) Base flow recession curve
II Say true or false, if false, give the correct statement.
(i) Unit hydrographs should be used for basins, larger than 5000 km
2
.
(ii) Larger unit periods are required for larger basins.
(iii) If the peak of the unit hydrograph is 25 cumec, then the peak of the hydrograph producing 8
cm of runoff is 215 cumec, assuming a constant base flow of 15 cumec.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 163
HYDROGRAPHS 163
(iv) The base flow of surface streams is the effluent seepage from the drainage basin.
(v) The ground water depletion curves are not of the same pattern for all the storms in a drain-
age basin.
(vi) When dealing with small streams, a hydrograph of instantaneous flow should be constructed,
wherever possible.
(vii) The best unit duration is about one-fourth of the basin lag.
(viii) The period of surface runoff is different for unit storms of different intensity.
(ix) If the period of surface runoff is divided into equal time intervals, the percentage of surface
runoff that occurs during each of these intervals will be different for unit storms of different
intensities.
(x) The hydrograph of runoff for a basin reflects the combined physical characteristics of the
basin including infiltration, surface detention and storage.
(xi) The inflection point signifies gradual withdrawal of catchment storage.
(xii) The unit storm is of such duration that the period of surface runoff is much less for any other
storm of shorter duration.
(xiii) The shape of the hydrograph of runoff will be affected by:
(i) the duration of the storm
(ii) areal distribution of the storm
(iii) the intensity of the storm (false: i, v, viii, ix, xii)
III Fill up the blanks correctly:
(i) The 3-hour unit hydrograph gives a net rain of ..... cm on the entire basin, for the rainfall
duration of .... hours.
(ii) To convert a unit hydrograph of a known duration to some other required duration ... tech-
nique is adopted.
(iii) The three basic propositions of the unit hydrograph theory are:
(a) .................
(b) .................
(c) .................
(iv) ............ hydrograph is constructed to serve as a unit hydrograph for a basin whose stream is
not gauged.
(v) The ground water contribution to the discharge in a stream is called .....
(vi) If the seepage from the stream builds up a ground water mound, such a stream is called
.........
IV Choose the correct statement/s in the following:
1 A 4-hr unit (1 cm) hydrograph means
(i) the duration of rainfall is 4 hours.
(ii) the intensity of rainfall over the entire catchment is 2.5 mm/hr constant.
(iii) 1 cm depth of rainfall over the entire catchment.
(iv) 1 cm depth of rainfall excess over the entire catchment.
(v) a hydrograph resulting from the instantaneous application of 1 cm rainfall excess over the
basin.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 164
164 HYDROLOGY
(vi) that the stream flow is for 4 hours.
(vii) that the volume of direct surface runoff in the stream is 10
4
A m
3
(A = area of basin in km
2
).
(viii) all the above.
2 Given a 4-hr unit (1 cm) hydrograph (UG), for any storm of 4-hr duration producing x cm of
rainfall excess
(i) the peak of direct runoff hydrograph (DRH) is x times the peak of UG.
(ii) the duration of direct surface runoff (DSR) is the same as that of UG.
(iii) if the duration of DSR in DRH and UG are divided into 8 unit periods, the percentage of DSR
in the corresponding unit periods in both, is the same.
(iv) the ratio of the corresponding ordinates in each unit period of DRH and UG is x.
(v) all the above relations.
3 A S-curve hydrograph derived from a 4-hr UG (time base T = 24 hr) for a 640 km
2
basin
(i) is the result of six 4-hr unit storms occurring in succession over the basin.
(ii) produces a constant outflow 445 cumec after 24 hours.
(iii) the constant outflow of 445 cumec is produced after 6 hours.
(iv) the shape of the curve in the first 24 hours is in the form of letter S.
(v) all the above items.
4 A synthetic unit hydrograph is developed
(i) for a basin whose stream is gauged.
(ii) for a basin over which no raingauge and stream gauge stations are established.
(iii) by measuring the mainstream lengths like L and L
ca
, and area of the basin.
(iv) by computing the basin slope.
(v) by taking certain constants from another basin, which is hydrometeorologically homogeneous.
(vi) for a basin having a raingauge network but with no stream gauging station
(viii) from items (iii) (v) and (vi) above.
5 The shape of the hydrograph is effected by
(i) non-uniform areal distribution of rainfall.
(ii) varying rainfall intensity.
(iii) shape of the basin.
(iv) direction of storm movement.
(v) all the above factors.
6 Given a 3-hr UG, the stream flow hydrograph due to a 6-hr storm producing 7 cm of rainfall
excess, can be derived by
(i) multiplying the 3-hr UGO by 7 and adding base flow, if any.
(ii) deriving a 6-hr UG, from the 3-hr UG, multiplying the 6-hr UGO by 7 and then adding base
flow, if any.
(iii) multiplying the 6-hr UGO (derived from the 3-hr UGO) by 7 and deducting the base flow, if
any.
(iv) if the storm had uniformly produced 3 cm in the first 3 hr and 4 cm in the next 3 hr, multiply-
ing the 3-hr UGO by 3 and then by 4, adding the DROs lagged by 3 hr, and then adding base
flow, if any. (1-i, ii, iv, vii; 2v; 3except iii, 4vi, vii; 5-v; 6-except iii)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 165
HYDROGRAPHS 165
OUE8TON8
1 (a) Define hydrograph. Draw a single-peaked hydrograph and indicate its various components.
(b) State the significance of the inflection point on the recession side of the hydrograph.
2 It is ascertained that various factors affect the shape of the flood hydrograph. What are those
factors? Grouping the above under rainfall factors, loss factors and physiographic factors, indi-
cate how all these affect the shape of the hydrograph.
3 Describe with the help of a neat sketch any three methods of separation of base flow from the
hydrograph of runoff (i.e., stream flow hydrograph) indicating the situations under which you
advocate them.
4 (a) What are the three basic propositions of the unit hydrograph theory ?
(b) The following are the ordinates of the hydrograph of flow from a catchment area of 780 km
2
due to a 6-hour rainfall. Derive the ordinates for 6-hour unit hydrograph for the basin and
state its peak.
Date Time from beginning Discharge Remarks
of rainfall (cumec)
(hr)
1-3-1980 6 40
12 64
18 215
2-3-1980 0 360
6 405 Peak
12 350
18 270
3-3-1980 0 205
6 145
12 100
18 70
4-3-1980 0 50
6 42
5 (a) What do you understand by a 6-hour unit hydrograph?
(b) A steady 6-hour rainfall with an intensity of 4 cm/hr produces a peak discharge of 560 cumec.
The average storm loss can be assumed as 1 cm/hr and base flow 20 cumec. What is the peak
discharge of the unit hydrograph and its duration? On the same basin, determine the peak
discharge from a 6-hour rainfall at an intensity of 3.5 cm/hr assuming an average loss rate of
1.5 cm/hr and base flow of 15 cumec. (30 cumec, 6-hr; 375 cumec)
6 (a) Explain the use of the unit hydrograph in the construction of the flood hydrgraph resulting
from two or more periods of rainfall.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 166
166 HYDROLOGY
(b) The following are the ordinates of 3-hour unit hydrograph:
Time 3-hr UGO Time 3-hr UGO
(hr) (cumec) (hr) (cumec)
0 0 15 9.4
3 1.5 18 4.6
6 4.5 21 2.3
9 8.6 24 0.8
12 12.0 27 0
Derive the flood hydrograph due to a 6-hour storm producing a total rainfall 4.5 cm in the first
three hours and 3.5 cm in the next three hours. Assume an average infiltration loss of 0.5 cm/hr
and a constant base flow of 3 cumec. State the peak flood in the stream and after how many
hours it will occur since the commencement of storm. Also state the basin lag (time lag).
7 (a) What is an instantaneous unity hydrograph?
(b) Given below are the streamflows from a catchment area of 20 km
2
due to a storm of 1-hour
duration. Find the surface runoff hydrograph ordinates from an effective rainfall (net rain) of
6 cm and of duration 1 hour. Assume a constant base flow of 15 cumec.
Time (hr): 0 1 2 3 4 5 6 7 8 9 10
Stream flow (cumec): 15 25 50 55 48 35 30 27 24 20 15
8 (a) What are the limitations of unit hydrograph?
(b) The stream flows due to three successive storms of 3.5, 4.5 and 2.5 cm of 6 hours duration
each on a basin are given below. The area of the basin is 45.4 km
2
. Assuming a constant base
flow of 10 cumec, and an average storm loss of 0.25 cm/hr, derive the ordinates of a 6-hour
unit hydrograph for the basin.
Time (hr): 0 3 6 9 12 15 18
Stream flow (cumec): 10 14 18 32 46 54 58
Time (hr): 21 24 27 30 33 36 39
Stream flow (cumec): 49 36 25 17 12 11 10
(0, 2, 4, 8, 12, 9, 4, 2, 1, 0)
9 The ordinates of a 3-hr UG are given in problem 6 (b). Derive the flood hydrograph due to a 3-hr
storm, producing a rainfall excess (net rain) of 4 cm. The base flow is estimated to be 3 cumec
and may be assumed constant. (3, 9, 21, 37.4, 51, 40.6, 21.4, 12.2, 6.2, 3 cumec)
10 (a) Define a S-curve hydrograph giving a neat sketch, and state its use.
(b) The ordinates of a 12-hour unit hydrograph are given below. Compute a 6-hour unit hydrograph
ordinates and plot: (i) the S-curve and (ii) the 6-hour UG
Time (hr): 0 6 12 18 24 30 36 42 48 54 60 66 72
12-hr UGO (cumec): 0 1 4 8 16 19 15 12 8 5 3 2 1
11 The ordinates of a 4-hour unit hydrograph are given below. Derive the ordinates of a 8-hour unit
hydrograph by the S-curve method or otherwise.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 167
HYDROGRAPHS 167
Time 4-hr UGO Time 4-hr UGO
(hr) (cumec) (hr) (cumec)
0 0 24 103
4 24 28 64
8 82 32 36
12 159 36 17
16 184 40 6
20 151 44 0
12 The ordinates of a 6-hour UG are given below. Derive the ordiantes of a 12-hour UG without
resorting to the S-curve technique.
Time (hr): 0 6 12 18 24 30 36 42 48 54 60
6-hr UGO (cumec): 0 5 13 30 35 32 20 14 8 4 0
13 The ordinates of a 3-hour UG are given in problem 6 (b). Derive the ordinates of a 6-hour UG and
state its peak.
14 (a) Explain synthetic unit hydrograph.
(b) A drainage basin has an area of 1700 km
2
.
Construct a 6-hour unit hydrograph, the data is given below:
Length of the longest water course = 82 km
Length along the main water course from the
gauging station to a point opposite the centriod
of the basin = 48 km
From another catchment, which is meteoro logically and hydrologically homogeneous, the
constants obtained: C
t
= 1.2, C
p
= 5
(14.5 hr, 587 cumec, 4.9 days; 18, 10 hr)
15 The following are the ordinates of a 6-hr UG for a basin:
Time (hr): 0 6 12 18 24 30 36 42 48
6-hr UGO (cumec): 0 20 56 98 127 147 156 154 140
Time (hr): 54 60 66 72 78 84 90 96
6-hr UGO (cumec): 122 107 93 78 65 52 41 30
Time (hr): 102 108 114 120 126 132 138 144
6-hr UGO (cumec): 20.7 14.5 10 6.7 4.5 2.2 1.1 0
Details of the gauged basin:
A = 3230 km
2
, L = 150 km, L
ca
= 76 km
Another basin which is meteorologically and hydrologically similar has the following details.
A = 2430 km
2
, L = 140 km, L
ca
= 75 km and the basin is not gauged.
Derive a 6-hour synthetic-unit hydrograph for the ungauged basin.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 168
168 HYDROLOGY
16 Synders method has been applied for the construction of synthetic-unit hydrograph for a sub-
catchment of Ramganga basin at Kalagarh in U.P., north India and the following data apply:
(a) For the whole Ramganga catchment:
Area of catchment = 3100 km
2
Peak of 24-hour design unit hydrograph = 782 cumec
Time to peak (from the beginning of rising limb) = 33 hours
Time hase = 4 days
L
L
ca
=
=
U
V
W
157 5
77 25
.
.
km
km
measured from the index map
(b) For the sub-catchment of Ramaganga:
Area of catchment = 323.5 km
2
L = 32 km
L
ca
= 24.96 km
Construct a 8-hour synthetic unit hydrograph for the sub-catchment of Ramganga.
(C
t
= 0.93, C
p
= 5.29, t
pr
= 8.59 hr
Q
p
= 199.3 cumec, T = 97.7 hr or 62.95 hr
W
50
= 9.43 hr, W
75
= 5.4 hr)
17 A drainage basin has an area of 3800 km
2
. Determine: (i) lag period, (ii) peak discharge, and (iii)
base period, of a 9-hour unit hydrograph from the following data:
L = 320 km, L
ca
= 200 km, C
t
= 0.9, C
p
= 4.0
18 Storm rainfalls of 3, 7.5 and 5.5 cm occur during the three successive hours over a 30 km
2
area.
The loss rate can be assumed as 1.5 cm/hr on an average. The distribution percentages for suc-
cessive hours are 5, 20, 40, 20, 10 and 5. Determine the stream flows for successive hours assum-
ing a constant base flow of 20 cumec, state its peak and when it is expected.
(26, 25, 70, 187, 311, 266, 143, 78, 37 cumec)
19 The design storm over a water shed has depths of rainfall of 4,6, 3.6 and 5.6 cmin successive 1-hr
periods. The 1-hr UG can be approximated by a trainagle of base of 9 hr with a peak of 50 cumec
occuring after 2 hr from the beginning. Compute the flood hydrograph assuming an average loss
rate of 6 mm/hr and constant flow of 5 cumec. What is the area of water shed and its coefficient
of runoff?
20 Distinguish between:
(i) a hydrograph and a hyetograph
(ii) lag time and recession time
(iii) a concentration curve and a recession curve
21 Write short notes on:
(i) Meteorological homogeneity
(ii) Ground water depletion curve
(iii) Bernards distribution graph
22 During a draught spell in a basin, the stream flow was 90 cumec after 10 days without rain, and
40 cumec after 30 days without rain. Derive the equation of the ground water depletion (reces-
sion) curve. What is the streamflow after 100 days without rain? What is the change in ground
water storage from 10 to 100 days without rain?
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 169
HYDROGRAPHS 169
23 A 3-hr UG for a basin can be approximated by a triangle of base 24 hr and peak (apex) of 50
cumec occuring after 8 hr from the beginning. A 4-hr storm occurred over the basin with an
intensity of 2.6 cm/hr. Assuming an average loss rate of 6 mm/hr and a constant base flow of 6
cumec, determine the streamflow at 4, 8 and 16 hr, respectively from the beginning. What is the
area of the drainage basin? Also determine the coefficient of runoff of the basin.
Hint C =
i W
i
i

(156, 306, 156 cumec; 216 km


2
; 0.8)
24 The flood at the Pampanga river at San Anton, Philippines during October 4-10, 1964 is given in
Table 1. The watershed area is 2851 km
2
. The hourly rainfall data measured by the recording
raingauges at Cabanatuan is given in Table 2.
(i) Plot the distribution of hourly rainfall as a histogram
(ii) Compute the index
(iii) Verify whether the computed value is correct by using the histogram
Table 1 Daily runoff data of Pampanga river
Date
Stream flow Base flow
(cumec) (cumec)
October 1964, 4 325 325
5 364 315
6 502 290
7 452 277
8 470 263
9 465 252
10 240 240
Table 2 Hourly rainfall data at Cabanatuan
Date Hour
Rainfall
Date Hour
Rainfall
(mm) (mm)
October 5, October 6 17 17.2
1964 9 14.3 18 2.0
10 8.0 19 0.9
11 7.2 20 1.5
12 N 3.8
13 2.0
14 1.3
October 6, 4 1.0
5 0
6 0.8 year
7 0
8 13.9
(Ans. 73.9 48.0 = 25.9 mm, 6.94 mm/hr))
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD5-3.PM5 170
170 HYDROLOGY
25 Storm rainfalls of 4.5 and 8 cm occurred over an area of 3750 km
2
on July 10 and 11, respectively
in a certain year. The loss rate can be assumed as 2.5 and 2 cm for the two days, respectively.
The distribution percentage for the successive days are 20, 40, 15, 12, 8, 4 and 1. Determine the
streamflows for the successive days in cumec, assuming a base flow of 40 cumec for the first 2
days, 80 cumec for the next 2 days, 60 cumec for further 2 days and 40 cumec for the subsequent
days. State the peak flood and the date of its occurence.
26 The flood water level (river stage H) since commencement of a 4-hr storm on a 2200 km
2
basin is
given below. Derive and sketch a 4-hr UH (unit is 1 cm), assuming a constant base flow of 9
cumec.
Time (hr): 0 2 4 6 8 10 12 14 16 18 20 22
Stage, H(m): 0.5 3.0 4.5 4.6 4.3 3.3 2.8 2.2 1.9 1.2 1.0 0.5
Stage-discharge relation : Q = 100 (H0.2)
2
, Q in cumec.
(Ans. P
net
= 2.86 cm; UHO: 0, 271, 644, 674, 585, 333, 233, 166, 98, 32, 19, 0, cumec)
27 Using the lag time of the SUH obtained in problem 16, for the sub-catchment of Ramganga
(A = 323.5 km
2
) develop a 8 hrUG by SCS method, given (pk = peak) :
t
t
pk
: 0.5 1 2 3 4 5
Q
Q
p
: 0.4 1 0.32 0.075 0.018 0.004
28 In a stream the base flow is observed to be 30 cumec on July 14, and 23 cumec on July 23.
Estimate the base flow on August 10, and ground water storage on July 14 and August 10.
(Ans. Q (28 days) = 13.5 cumec; 88, 40 Mm
3
)
29 An agricultural watershed was urbanised over a period of 30 years. The rainfall loss was
9 mm/hr before urbanisation, which dropped to 4 mm/hr after urbanisation. The 1-hr UG (unit
1 cm) of this watershed can be assumed as a triangle of base 12 hr and height 160 cumec after 4
hr before urbanisation and of base 8 hr and height 240 cumec after 3 hr, after urbanisation.
(a) Determine the area of the watershed.
(b) Draw the flood hydrograph after urbanisation for a storm of intensity 19 mm/hr for 1 hr and
29 mm/hr in the next hour. Assume a uniform loss rate and a constant base flow of 10 cumec.
(c) Compute the coefficient of runoff before and after urbanisation.
(Ans. A = 346 km
2
, C = 0.67, 0.83]
Note The triangular areas of both the UGs are same.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
6.1 METHODS OF MEASURING STREAM FLOW
The most satisfactory determination of the runoff from a catchment is by measuring the
discharge of the stream draining it, which is termed as stream gauging. A gauging station is
the place or section on a stream where discharge measurements are made. Some of the usual
methods of stream gauging are given below:
(a) Venturiflumes or standing wave flumes (critical depth meter) for small channels.
(b) Weirs or anicuts: Q = CLH
3/2
...(6.1)
where Q = stream discharge, C = coefficient of weir, L = length of weir (or anicut), H = head
(depth of flow) over the weircrest
(c) Slope-area method: Q = AV ...(6.2)
V = C
RS
Chezy ...(6.2 a)
V =
1
n
R
2/3
S
1/2
Manning ...(6.2 b)
Chezys C =
1
n
R
1/6
, R =
A
P
...(6.2 c)
where C = Chezys constant
N = Mannings coefficient of roughness
R = hydraulic mean radius
A = cross-sectional area of flow
P = wetted perimeter
S = water surface slope (= bed slope)
The cross-sectional area A is obtained by taking soundings below the water level at
intervals of, say, 6 m and plotting the profile of the cross-section and drawing the high flood
level or water surface level.
The water surface slope is determined by means of gauges placed at the ends of the
reach, say 1 km upstream of the gauging station and 1 km downstream of the gauging station
(in a straight reach; if h is the difference in water levels in a length L of the reach, then
S =
h
L
. The slope may also be determined by means of flood marks on either side and their
subsequent levelling.
STREAM GAUGING
171
Chapter 6
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 172
172 HYDROLOGY
Careful notes on the nature of bed and banks, vegetation etc. should be made and if
possible a photograph may be taken. From this, the constants C (Chezys) and n (Mannings)
can be found from the Tables.
The slope-area method is often used to estimate peak floods where no gauging station
exists.
(d) Contracted area methods:
The drop in water surface in contracted sections as in bridge openings (see Fig. 6.15),
canal falls etc. is measured and the discharge is approximately given by
Q = C
d
A
1
2g h h
a
( ) + ...(6.3)
where C
d
= coefficient of discharge
A
1
= area of the most contracted section
h = difference in water surface between the upstream and down stream ends (of the
pier)
h
a
= head due to the velocity of approach.
(e) Sluiceways, spillways and power conduits. The flow through any of the outlets in a
dam or the sum of the flows through these gives the discharge at any time.
(f) Salt-concentration method. The discharge is determined by introducing a chemical,
generally common salt, at a known constant rate into flowing water and determining the quan-
tity of chemical in the stream at a section downstream sufficiently distant to ensure thorough
mixing of the chemical with water. The discharge.
Q =
c c
c c

2
2 1
q ...(6.4)
where q = quantity of solution injected (cc/sec)
c = amount of salt in dosing solution (gm/cc)
c
1
= concentration of salt originally (before dosing) in the stream (gm/cc)
c
2
= concentration of salt in the sample downstream (gm/cc)
This method is best suited for turbulent waters as the turbulence helps in thorough
mixing of the chemical; this is a costly process.
(g) Area-velocity methods: Q = AV
The area of cross-section of flow may be determined by sounding and plotting the profile.
The mean velocity of flow (V) may be determined by making velocity measurements. The velocity
distribution in a cross-section and in a vertical in a stream are shown in Fig. 6.1 (a) and (b) and
as such the methods of velocity measurements are as follows:
Velocity measurements from
Floats
surface
sub-surface
measure surface velocity ;
0.85
Velocity rods measure mean velocity,
Current meter
Pigmy
Propeller
Price
measure mean velocity in a
strip of cross-section by
{ }
v
V v
V
s
s

R
S
|
T
|
U
V
|
W
|
R
S
|
|
|
|
T
|
|
|
|
...(6.5)
(i) one point method V = v
0.6d
...(6.6 a)
(ii) two points method V =
v v
d d 0.2 0.8
2
+
(d = mean depth in the strip) ...(6.6 b)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 173
STREAM GAUGING 173
Water surface
x
x
Stream
bed & banks
0.1 m/sec
0.2
0.4
0.6
0.8 m/sec
Water
surface
Surface velocity
x
v
s
=
V
0.85
Stream
flow
Depth d
0.2d
0.5d
0.6d
0.8d
v
0.2d
v
0.5d
v
0.6d
v
0.8d
Stream bed
V
x
Mean velocity
= 0.85 v
= v
=
s
0.6d
v
2
0.2d
+ v
0.8d
V
a. Velocity profile along a cross section b. Velocity profile along a vertical
XX (vertical scale exaggerated)
Fig. 6.1 Horizontal and vertical velocity profiles in a stream
Surface floatsconsist of wooden discs 715 cm diameter (Fig. 6.2 a). The time (t) taken
by float to travel a certain distance (L) is meaured and the surface velocity v
s
and mean veloc-
ity V are calculated as v
s
= L/t and V 0.85 v
s
. The reach of the river for float measurements
should be straight and uniform and least surface disturbances. The float travel is affected by
winds, waves and eddies and sometimes a subsurface or a double float consisting of a metallic
hollow cylindrical weighted submerged float attached by means of a thin string to a surface
float is used, Fig. 6.2 a.
a. Types of floats
Surface floats
Subsurface
float
Velocity
rod
Water surface
0.06 d
0.94 d
d
0.6 d
Wire
taut
Flow direction
River bed
Weighted
Lead
weight
b. Float run
Fixed
reference gauge
Float run
Pole rope River bank
Flow
Starting line
of float
Fig. 6.2 Velocity determination by floats
Velocity rods consist of a wooden rod, square or round in section ( 3-5 cm size). It is
weighted at the bottom by means of lead or cast iron rings to immerse it to a depth of 0.94d,
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 174
174 HYDROLOGY
where d is the depth of stream, to give the mean velocity of flow (V). The rods are so weighted
that they float nearly vertical with about 35 cm projecting above the water surface, so that
they can be seen floating. A number of rods are required to suit the varying depths of cross-
section.
At the beginning of the gauge run, a surface or rod float is released at the centre of a
compartment (Fig. 6.2 b). The time taken for the float to reach the end of the gauge run (of the
same compartment) is noted. Knowing the length of the gauge run, the velocity of flow is
determined.
6.2 CURRENT METER GAUGINGS
The current meter is an instrument, which has a rotating element which when placed in flow-
ing water, the speed of revolutions has a definite relation with the velocity of flow past the
element. There are three types of current meters(i) pigmy current meter, whose cup vane
assmbly is about 5 cm in diameter and is used for measuring velocities in streams of depth 15
cm or less, (ii) the cup type, which consists of a wheel with conical cups revolving on a vertical
axis, and (iii) the screw or propeller type consisting of vanes revolving on a horizontal axis.
Price, Ellis, Ottwatt meters are of vertical axis type while Off and Haskel, Amslar, Ott and
Aerofoil meters are of horizontal axis type. The Price meter is regarded as a universal meter
and is equipped with a pentahead, a device for indicating every fifth revolution. The meter
may be used for velocities from 1 to 4.5 m/sec in depths of 1-15 m from a boat, bridge, cable or
wading. A counter weight (stream lined) is fixed below the meter to prevent it from swaying,
Fig. 6.3.
Rod
Tail vane
Suspension
cable
Connection
to ear phone
Flow
Funnels on
vertical axis
Counter weight
Fig. 6.3 Price current meter
Rating of the Current Meter
The relationship between the revolutions per second (N, rps) of the meter and the velocity of
flow past the meter (v, m/sec) has to be first established, or if the rating equation is given by
the maker, it has to be verified. This process of calibration of the meter is called rating of the
current meter. The rating equation is of the form
v = aN + b ...(6.7)
where a and b are constants (determined from rating of the current meter).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 175
STREAM GAUGING 175
The rating is done in a masonry tank of approximate dimensions 90 m 2.4 m 2.1 m,
Fig. 6.4. The meter is towed in still water in the tank either by a pushing trolley (from which
the meter is suspended) by men specially trained for the purpose or by an electric motor to
move the trolley at a constant speed on a track by the side of the tank, the distances being
painted in m and cm in enamel on the track. A metronome adjusted to give ticks at every 2, 3,
4, 5, 6, 7, 8, 10 sec is kept on the trolley. The men pushing the trolley would have been trained
to put paces uniformly to synchronise with the ticking of the metronome. When motorised
speeds are adjusted to give different velocities. A cantilever beam is fixed to the trolley such
that the projecting end is at the centre of the rating tank from which the meter is hung from a
suspension rod. The meter should be immersed about 1 m below the water surface during
rating. The observer sits in the trolley, notes the time and distance traversed by the trolley for
a fixed number of revolutions made by the meter (say, 10-100 depending on the speed). This
operation is repeated for different pushing velocities of the trolley. A current meter rating
curve is drawn as pushing velocity vs. rps, which plots a straight line and the constants a and
b are determined as shown in Fig. 6.5.
Current meter
towed
Hanger
Still water
Rating tank: 90 2.4 2.1 m
Rails
Metronome
Moving trolley
3 6 9
1
2
1
5
1
8
2
1
2
4
2
7
3
0
3
3
3
6
3
9
4
2
4
5
4
8
5
1
5
4
5
7
6
0
6
3
6
6
6
9
7
2
7
5
Distances painted
a. Plan
Moving trolley
Current meter
towed in still water
b. Cross section
Fig. 6.4 Current meter rating tank
Dy
Dx
Dy
Dx
a =
Slope
Rating curve
v = aN + b
b = intercept
Rev/sec of meter (N)
P
u
s
h
i
n
g
v
e
l
o
c
i
t
y
,
o
r
m
o
t
o
r
s
p
e
e
d
v
(
m
/
s
e
c
)
v =
or = Speed of motor
distance towed (m)
time (sec)
Fig. 6.5 Current meter rating curve
Stage-Discharge-Rating Curve
Once the rating equation of the current meter is known, actual stream gauging can be done
from bridges, cradle, boat or launch. The cross section of the stream at the gauging site is
divided into elemental strips of equal width b and the current meter is lowered to a depth of
0.6 d below water surface in shallow depths (one-point method) and to depths of 0.2d and 0.8d
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 176
176 HYDROLOGY
(two-points method) in deep waters, at the centre of each strip, Fig. 6.6. The mean depth (d) at
the centre of each strip is determined by sounding. The revolutions made by the meter in a
known time at the appropriate depths are noted by an ear phone (connected through a wire to
the penta or monocounter of the meter and the other to a dry cell) from which the velocities at
the appropriate depths are determined from the rating equation, Eq. (6.7).
b b b b
Cable
drum
Crab
winch
Pulley steel cable
Steel trestle
Left bank
0.6d
Hand propeller
Pulley
Cable car
Right bank
Pulley
High water level
Stream bed
Elemental strips
of width (b)
.8d .8d
.2d
Depth (d)
by sounding
Current meter
lowered at 0.8d
Q = Q S D
.6d
Anchor
Masonry
foundation
Current
meter positions
DQ (Strip) = (b.d)
v + v
2
.2d .8d
DQ (end strips) = (b.d) v
.6d
or
0.6d
C
Fig. 6.6 Current meter gauging
It may be noted that the mean velocity is taken as that at 0.6d below water surface in
shallow water (one-point method), and as the average of the velocities at 0.2d and 0.8d below
the water surface (two-point method) in deep waters, as can be seen from the velocity distribu-
tion in a vertical in a stream section, Fig. 6.1 (b). The discharge in each elemental strip is
determined and the discharge in the stream is the sum of the discharges in all the elemental
strips.
There are two methods of determining the discharge in each elemental strip:
(i) Mid-section method. In this method, the vertical in which the velocity measure-
ments are made (by one-point or two-points method) is taken as the middle of the strip, and
the water depth (d) in the vertical (determined by sounding) is taken as the mean depth of the
strip, Fig. 6.7 (a). If b is the width of strip (usually same for all strips) then the discharge in the
elemental strip is given by
Q = (bd) v
0.6d
in shallow strips ...(6.8)
Q = (bd)
v v
d d 0.2 0.8
2
+
in deep water strips ...(6.8 a)
stream discharge, Q = Q ...(6.8 b)
In this method, the discharge in the two-triangular bits near the ends are not included
in the discharge computation.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 177
STREAM GAUGING 177
b b b b b b
L.B.
M
d
1
d
2
d
3
d
4
d
5
d
6
N
Current
meter
locations
Verticals for
mean depth and
mean velocity
R.B.
D D s or M & N not
included in
computation of
discharge
DQ (Strip) = (b.d)
or
= (b.d) v
.6d
v + v
.2d .8d
2
a. Mid-section method
L.B.
R.B.
b b b b b b b
1
2
3
4
5
6
7
d
1
d
2
d
3
d
4
d
5
d
6
d
m
v
m
Mean sections
of strips
Strips 1-7 DQ (Strip) = (b.d ) v
m m
d
m
= ,
(for strip 3)
d + d
2
2 3
v
m
=
v +
2
2 3
v
b. Mean-section method
Q = Q S D
Fig. 6.7 Mid-section and Mean-section methods
(ii) Mean-section method. In this method, the elemental strip is taken between two ver-
ticals and the mean depth is taken as the average of the depths in the two verticals (deter-
mined by sounding). The width of the strip is distance b between the two verticals. The velocity
in the strip is taken as the average of the mean velocity determined in the two verticals (by
one-point or two-points method), Fig. 6.7 (b). The discharge in the elemental strip is given by
Q = b
d d V V
1 2 1 2
2 2
+ F
H
G
I
K
J
+ F
H
G
I
K
J ...(6.9)
V
1
, V
2
determined as v
0.6d
in shallow strip
and
v v
d d 0.2 0.8
2
+
in deep water strip ...(6.9 a)
Stream discharge, Q = Q ...(6.9 b)
The mean section method is considered to be slightly more accurate, but the mid-section
method is faster and is generally used.
Example 6.1 The following data were collected for a stream at a gauging station. Compute the
discharge.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 178
178 HYDROLOGY
Distance from depth, d Immersion of current meter
one end of (m) below water surface
water surface at 0.6d at 0.2d at 0.8d
(m) Rev. Sec. Rev. Sec. Rev. Sec.
3 1.4 12 50
6 3.3 38 52 23 55
9 5.0 40 58 30 54
12 9.0 48 60 34 58
15 5.4 34 52 30 50
18 3.8 35 52 30 54
21 1.8 18 50
Rating equation of current meter: v = 0.3 N + 0.05, N = rps, v = velocity, (m/sec), Rev.-Revolutions, Sec-
time in seconds.
Solution The discharge in each strip, Q = (bd) V, where V is the average velocity in each
strip, Fig. 6.8. In the first and the last strips (near the banks) where the depth is shallow,
V = v
0.6 d
, and in the other five intermediate strips (with deep water), V =
v v
d d 0.2 0.8
2
+
. Width of
each strip, b = 3 m, mean depth of strip = d, and the total discharge, Q = Q = 20.6 cumec,
as computed in Table 6.1.
Not considered
7 Elemental strips (b = 3 m)
Not considered
L.B
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
3
m
1
2 3 4 5 6
7
1.4
m
3.3
m 5.0
m
9.0
m
5.4
m
3.8
m
1.8
m
Meter location
at 0.6d
Meter location
at 0.6 d
Meter locations
at 0.2d & 0.8d
in vertical
V in vertical
= (V + V ) or V
mean
0.2d 0.8d 0.6d
1
2
Q = Q = (b.d) V
mean
7
1
1
1
R.B
0
21 m
Fig. 6.8 Discharge computation (Example 6.1)
6.3 STAGE-DISCHARGE-RATING CURVE
A river is gauged by current meter throughout the rainy season (for about 3 months) at different
stages (water levels) of the river. The water stage can be read on the enamel painted staff
gauges (gauge posts) erected at different levels at a gauging station Fig. 6.9; it may be noted
that corresponding graduation of gauge posts at two locations are fixed at the same level. A
curve is drawn by plotting stream discharge Q vs. gauge height h which is called the stage-
discharge rating curve as shown in Fig. 6.10. From this rating curve, the stream discharge
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 179
STREAM GAUGING 179
D
i
s
t
a
n
c
e

f
r
o
m
D
e
p
t
h
,

d
I
m
m
e
r
s
i
o
n

o
f

c
u
r
r
e
n
t

m
e
t
e
r

b
e
l
o
w

w
a
t
e
r

s
u
r
f
a
c
e
A
v
e
r
a
g
e
D
i
s
c
h
a
r
g
e

i
n

s
t
r
i
p
o
n
e

e
n
d

o
f
(
m
)
d
e
p
t
h

=

x
d
R
e
v
.
t
i
m
e
N

=

R
/
t
v

=

0
.
3

N

+

0
.
0
5
v
e
l
o
c
i
t
y

Q

=

(
b
d
)

V
w
a
t
e
r

s
u
r
f
a
c
e
(
x

=

0
.
6
,

0
.
2
,

0
.
8
)
R
(
s
e
c
.
)
(
r
p
s
)
(
m
/
s
e
c
)
i
n

s
t
r
i
p
b

=

3
m
(
m
)
(
m
)
V

(
m
/
s
e
c
)
3
1
.
4
0
.
8
4
1
2
5
0
0
.
2
4
0
.
1
2
2
0
.
1
2
2
0
.
5
1
6
3
.
3
0
.
6
6
3
8
5
2
0
.
7
3
0
.
2
6
9
0
.
2
2
3
*
2
.
1
6
2
.
6
4
2
3
5
5
0
.
4
2
0
.
1
7
6
9
5
.
0
1
.
0
0
4
0
5
8
0
.
6
9
0
.
2
5
7
0
.
2
3
6
3
.
5
4
4
.
0
0
3
0
5
4
0
.
5
6
0
.
2
1
8
1
2
9
.
0
1
.
8
0
4
8
6
0
0
.
8
0
0
.
2
9
0
0
.
2
5
9
7
.
0
0
7
.
2
0
3
4
5
8
0
.
5
9
0
.
2
2
7
1
5
5
.
4
1
.
0
8
3
4
5
2
0
.
6
5
0
.
2
4
5
0
.
2
3
8
3
.
8
5
4
.
3
2
3
0
5
0
0
.
6
0
0
.
2
3
0
1
8
3
.
8
0
.
7
6
3
5
5
2
0
.
6
7
0
.
2
5
1
0
.
2
3
4
2
.
6
8
3
.
0
4
3
0
5
4
0
.
5
6
0
.
2
1
8
2
1
1
.
8
1
.
0
8
1
8
5
0
0
.
3
6
0
.
1
5
8
0
.
1
5
8
0
.
8
6
T
o
t
a
l

Q

=

2
0
.
6
0

c
u
m
e
c
*

0
2
6
9
0
1
7
6
2
.
.
+

=

0
.
2
2
3
.
T
a
b
l
e

6
.
1

C
u
r
r
e
n
t

m
e
t
e
r

g
a
u
g
i
n
g

o
f

R
i
v
e
r
.

(
E
x
a
m
p
l
e

6
.
1
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 180
180 HYDROLOGY
corresponding to staff gauge readings taken throughout the year/s can be obtained, as long as
the section of the stream at or near the gauging site has not materially altered. Periodical
gaugings (say, once in three years) are conducted to verify the rating curve, or to revise the
rating curve if any change in section has been noticed.
5.0
7.5
m
Staff gauges
(enamel painted)
5.0
m
High water level
2.5
m
2.5
Stream
bank
Flow Q (cumec)
River bed
h
o
Staff reading
(Gauge height, h)
Fig. 6.9 Gauge posts on river bank
Stage-discharge
rating curve
Log-log paper
Staff guage reading 0.7 m
Discharge
20 cumec
10
8
6
4
3
2
1.0
.8
.6
.4
.3
.2
0.1
1 2 3 4 6 8 10 20 30 50 70 100 200 400 600 1000
Stream discharge, Q (cumec)
G
a
u
g
e
h
e
i
g
h
t
(
h
m
)
Fig. 6.10 Stage-discharge rating curve
For a continuous record of water stage (gauge heights or readings) during floods, an
Automatic Water Stage Recorder (AWLR) is installed inside a gauge well on one of the banks
of the stream at the gauging site, connected to the stream at different levels by pipes, Fig. 6.11.
A steel wire rope with a float at one end and a counter weight at the other passes over a pulley
connected to a cylindrical drum over which a chart is wrapped. The rise and fall of the float
with the water level causes rotation of the drum while a clock mechanism moves a pen axially
along the drum, thus producing a water stage hydrograph. The time scale on the graph is
usually so chosen as to cover a weeks period. Thus, a continuous record of the river stage with
the time is obtained. The water level in well is not subject to fluctuations caused by wind or
waves.
If the river is subject to scour, the well should be sufficiently deep and the zero of the
gauge should be sufficiently below the bed, so that the water surface will not come below the
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 181
STREAM GAUGING 181
bottom of the well or below the zero gauge reading due to scour of the river bed. Thus, the
gauge height (gauge reading) corresponding to zero discharge varies according to the degree of
scour or deposition but is always a positive number (h
0
).
h
Gauge
float
Gauge
well
Staff
gauge
Zero of
gauge
Drum with
chart-mounted
clock mechanism
Recorder pen
Pulley
Float counter
weight
Pipe connection
High water level
Maximum probable scour
of stream bed
River
Q = K(h h ) cumec
o
n
River bed
h
o
0.00
Fig. 6.11 River stage recorder
Extension of Stage-Discharge Rating Curve
If h
0
is the gauge reading corresponding to zero-discharge and h is the gauge reading when the
discharge is Q, the gauge height is (h h
0
) for this discharge Q. The relation between stream
discharge and gauge height can be expressed as
Q = K (h h
0
)
n
...(6.10)
where K and n are the constants for any stream gauging station.
log log Q K
y c
! !
= + n
m
B

log ( ) h h
x

B
0
"" ! ""
...(6.10 a)
Hence, the plot of Q vs. (h h
0
) on a lag-lag paper gives a straight line whose slope is n
and K = Q when (h h
0
) = 1, Fig. 6.12.
Usually the value of h
0
is not known and the observations made are values of Q corre-
sponding to gauge readings h. Then, h
0
is determined by assuming trial values; for example for
assumed value of h
0
= 1.2, the discharge rating curve is concave upward and for a value of h
0
=
0.6 the curve is concave downward; for some intermediate value h
0
= 0.9, it is a straightline
plot and can be extended to higher stages once the value of h
0
is determined, the scale of
(h h
0
) may be replaced by gauge reading h, since h = (h h
0
) + 0.9, to facilitate direct reading
of stream discharge for any observed gauge reading h. It is customary to plot the rating curve
with Q as abscissa and h as ordinate, Fig. 6.10.
Adjustment of Stage-Discharge Rating Curve
When discharge measurements are made during both rising and falling stages and also
at constant stage, the points joining the rising and falling stages plot a loop due to channel
storage and variation of water surface slope as a flood wave moves along the stream, Fig. 6.13.
A smooth discharge curve is then drawn along the median line passing through or near the
points that were obtained at constant stage. Whenever stream gauging is conducted for deter-
mining or checking the discharge-rating curve, the gauge reading and time are recorded at the
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 182
182 HYDROLOGY
beginning and at the end of the gauging to calculate the rate of change in stage. Curves-
relating percentage correction to discharge and rate of change in stage can be obtained from
continuous discharge measurement during rising, falling and constant stages of the river.
1000
800
600
400
300
200
150
100
80
60
40
30
20
15
10
8
6
5
4
3
2
1.5
1
D
i
s
c
h
a
r
g
e
,
Q
(
c
u
m
e
c
)
0.1 .15 .2 .3 .4 .6 .81.0 1.5 2 3 4 6 8 10 15 20 30 40 60 80
100
1.0 1.1 1.2 1.4 1.6 1.9 2.9 4.9 6.9 10.9 20.9 40.9
Gauge reading h (m)
Lag-lag paper
Q = 240 cumec
Q = 1.2 (h-0.9)
2.2
(h h ) = 1
o
K = Q = 1.2
= 3.6 cm
h
=
1
.
2
o
h
=
0
.
6
o
C
o
n
c
a
v
e
u
p
w
a
r
d
C
o
n
c
a
v
e
d
o
w
n
w
a
r
d

y = 7.92 cm
S
t
r
a
i
g
h
t
l
i
n
e
0
.
9
12 m = h
Slope n = = = 2.2
of st. line

y
x

7.92
3.60
h
=
o
Q = 25.3 cumec
(h h ) m
o

x
Fig. 6.12 Extension of stage-discharge-rating curve (Example 6.2)
Correction has to be applied for the discharge obtained from the rating curve during a
rising or falling stage i.e., during a flood. For this purpose, an auxiliary gauge is established
some distance upstream or downstream from the main gauge (Fig. 6.14). If Q
0
is the discharge
when h
0
is the difference of gauge readings between the main and auxiliary gauges during
normal flow, and Q
a
is the discharge when h
a
is the difference of the two gauges during a
rising or falling stage then
Q
Q
a
0
=

h
h
a
n
0
F
H
G
I
K
J ...(6.11)
where the exponent n 0.5, since Q varies as the square root of the energy gradient, which in
turn varies with h, the distance between the gauges being constant.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 183
STREAM GAUGING 183
Uniform flow rating
curve (median line)
R
i
s
i
n
g
s
t
a
g
e
F
a
l
l
i
n
g
s
t
a
g
e
W
a
t
e
r
s
t
a
g
e
h
(
m
)
Discharge Q (cumec)
Fig. 6.13 Adjustment of flow rating curve
Water surface
Main gauge
Auxiliary gauge
Rising stage
N
orm
al stage
Falling stage

h
a

h
o
Flow
Stream bed
h
h
a
o

Q = Q
a o
n
n = 0.5
Fig. 6.14 Auxiliary gauge for flow adjustment
From Eq. (6.11) the actual discharge Q
a
during a rising or falling stage can be deter-
mined. The distance between the two gauges should be such that h
0
is at least 0.3 m, to avoid
observational errors.
6.4 SELECTION OF SITE FOR A STREAM GAUGING STATION
The following factors have to be considered in selecting a site for a stream gauging station.
(i) The section should be straight and uniform for a length of about 10 to 20 times the
width of the stream.
(ii) The bed and banks of the stream should be firm and stable so as to ensure consist-
ency of area-discharge relationship, i.e., the cross section should not be subjected to change by
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 184
184 HYDROLOGY
silting or scouring, during different stages of flow; a smooth rock, shingle or clay bed is favour-
able, while a fine sandy bed is unfavourable.
(iii) The bed and banks should be free from vegetal growth, boulders or other obstruc-
tions like bridge piers, etc.
(iv) There should be no larger overflow section at flood stage. The best cross section is
one with V-shape, so that there is sufficient depth for immersing the current meter without
being affected by the bed roughness of the stream.
(v) The part of the reach having the most regular transverse section and steady flow
with the current normal to the metering section and velocities in the range of 0.31.2 m/sec
should be selected.
(vi) To ensure consistency between stage and discharge, there should be a good control
section far downstream of the gauging site. This control may be in the form of steep rapids,
large rocky boulders, restricted passages, crest of weirs or anicuts etc.
(vii) The sites above the confluence of rivers are best avoided if the flow is affected by
back water conditions due to the varying discharges in the tributaries.
(viii) The stream gauging station should be easily accessible.
Example 6.2 The stream discharges for various stages at a particular section were observed to
be as follows. Obtain an equation for the stage-discharge relationship and determine the dis-
charge for a stage of 4.9 m and 12 m.
Stage (m) 1.81 2.00 2.30 2.90 3.70 4.50
Discharge (cumec) 1.00 1.50 2.55 5.60 11.70 20.20
Stage (m) 5.40 6.10 7.30 7.70 8.10
Discharge (cumec) 32.50 44.50 70.0 80.0 90.0
Solution The relation between the stage (h) and discharge (Q) of the stream can be assumed
of the form
Q = K (h a)
n
, (similar to Eq. (6.10)
where K, a and n are the constants. Plot Q vs. (h a) on a lag-lag paper assuming a value for
the constant a = 0.6 m (say); the curve obtained is concave downwards, Fig. 6.12. Now assume
a value a = 1.2 m (say) and the curve obtained is concave upward. Now try an intermediate
value a = 0.9 m, which plots a straight line and represents the stage discharge relationship.
The slope of this straight line gives the value of the exponent n = 2.2, and from the graph for
h a = 1, Q = 1.2 = K. Now the constants are determined and the equation for the stage-
discharge relationship is
Q = 1.2 (h 0.9)
2.2
It may be noted that the value of a = 0.9, which gives a straight line plot is the gauge
reading for zero discharge. Now the abscissa of (h a) may be replaced by the gauge reading
(stage) h, by adding the value of a to (h a) values. For example the (h a) values of 0.1, 1, 2,
4, 6, 8 and 10 may be replaced by the h values of 1, 1.9, 2.9, 4.9, 6.9, 8.9 and 10.9 respectively.
Now for any gauge reading (stage) h, the discharge Q can be directly read from the graph and
the stage discharge curve can be extended. From the graph, Fig. 6.12,
for h = 4.9 m, Q = 25.3 cumec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 185
STREAM GAUGING 185
and for h = 12.0 m, Q = 240 cumec
which can be verified by the stage-discharge equation obtained as
for h = 4.9 m, Q = 1.2 (4.9 0.9)
2.2
= 25.3 cumec
for h = 12 m, Q = 1.2 (12 0.9)
2.2
= 240 cumec
Note The equation for the stage-discharge relation can also be obtained by Linear Regression
by assuming trial values of a and computer-based numberical analysis. See chapter13.
Example 6.3 The following data were obtained by stream gauging of a river:
Main gauge staff reading (m) 12.00 12.00
Auxiliary gauge staff reading (m) 11.65 11.02
Discharge (cumec) 9.50 15.20
what should be the discharge when the main gauge reads 12 m and the auxiliary gauge reads
11.37 m?
Solution h
0
= 12.00 11.65 = 0.35 m
h
a
= 12.00 11.02 = 0.98 m
Eq. (6.10):
Q
Q
h
h
a a
n
0 0
=
F
H
G
I
K
J


15 20
9 50
0 98
0 35
.
.
.
.
=
F
H
G
I
K
J
n
n = 0.5125
Again, when the auxiliary gauge reads 11.37 m,
h
a
= 12.00 11.37 = 0.63 m

Q
a
9 50
0 63
0 35
0.5125
.
.
.
=
F
H
G
I
K
J
Q
a
= 12.85 cumec
Example 6.4 A bridge has to be constructed over a river, which receives flow from three branches
above the site. Compute the maximum flood discharge at the bridge site from the following
data:
Branch 1 has a bridge:
Width of natural water way 324.0 m
Lineal water way under the bridge
(with C
d
= 0.95 for rounded entry) 262.5 m
Depth upstream of bridge 4.6 m
Depth downstream of bridge 2.8 m
Branch 2 has a catchment area of 4125 km
2
Ryves C = 10
Branch 3 levelling of cross section (c/s) data:
Distance from BM (m) 0 11 24 52 67 79 84
RL on c/s (m) 10.8 9.6 4.2 2.4 5.4 10.2 10.5
Levelling of longitudinal-section (L/S) data:
Distance from 1 km at 1 km
bridge site upstream bridge site downstream
HFL along L/S (m) 9.60 9.0 8.39
Mannings n may be assumed at 0.03.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 186
186 HYDROLOGY
Solution (i) Discharge from Branch 1, i.e., Q
1
under bridge openings, Fig. 6.15, from Eq. (6.3)
Q
1
= C
d
A
1
2g h h
a
( ) +
If L, d, V and L
1
, d
1
, V
1
refer to the length, mean depth and velocity of the normal
stream (upstream of bridge site) and those under the contracted section of the bridge and also
A
1
= L
1
d, Q
1
= LdV, h
a
=
V
g
2
2
Flow
d
Afflux h

V
a. Cross section
Superstructure Parapet
Lineal water way
L = 3L
1
Abutment Abutment
l
MWL
Piers
Foundation on
hard rock
b. Flow through bridge openings
l l
Fig. 6.15 Flow through bridge openings (Example 6.4)
Eq. (6.3) after substitution and simplification yields the expression for afflux (i.e., head-
ing up of water on the upstream face of the bridge openings) as
Afflux h =
V
g
L
C L
d
2 2
2
1
2
2
1
F
H
G
I
K
J
...(6.12)
If the Branch 1, flow under bridge openings
4.6 2.8 =
V
2 2
2 2
2 9 81
324
0 95 262 5
1


F
H
G
I
K
J
. . .
V = 7.16 m/sec
Q
1
= LdV = 324 2.8 7.16 = 6500 cumec
(ii) Discharge from Branch 2:
From Ryves formula (see Eq. 8.2)
Q
2
= CA
2/3
...(6.13)
= 10 (4125)
2/3
= 2580 cumec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 187
STREAM GAUGING 187
(iii) Discharge from Branch 3 (from slope-area method): See Table 6.2 for computation
C/S area and wetted perimeter, Fig. 6.16.
Table 6.2 Computation C/S area and wetted perimeter (Fig. 6.16)
Area Area Area, A
1
Wetted perimeter, P
1
no. shape (m
2
) (m)
1.
1
2
11.55 4.8 = 27.75 1155 4 8
2 2
. . + = 12.5
2.
1
2
(4.8 + 6.6) 28 = 159.60 28 18
2 2
+ . = 28.2
3.
1
2
(6.6 + 3.6)15 = 76.50 15 3
2 2
+ = 15.2
4.
1
2
9 3.6 = 16.20 9 3 6
2 2
+ . = 9.7
A = 280.05 P = 65.6
13
11.55
.6
4.8
28
1.8
3
9.0 H.F.L.
1.2
12
9
3.6
15
79 84
10.2 10.9
67
5.4
52
2.4
24
4.2
11
9.6 10.8
0
R.L.
Dist.
Fig. 6.16 Cross section of river at bridge site (Example 6.4)
Hydraulic mean radius, R =
A
P
=
280 05
65 6
.
.
= 4.27 m
Water surface slope, S =
h
L
=

=
9 60 8 39
2 1000
1
1652
. .
By Mannings formula, the velocity of flow
V =
1
n
R
2/3
S
1/2
=
1
0 03
4 27
1
1652
2 3
.
( . )
/
1/2
= 2.16 m/sec
Q
3
= AV = 280.05 2.16 = 605 cumec
Discharge at bridge site
Q = Q
1
+ Q
2
+ Q
3
= 6500 + 2580 + 605 = 9685 cumec
OUZ V
I Choose the correct statement/s
The method of measuring discharge in a turbulent stream is
(i) by measuring the drop in water surface under bridge openings and canal falls.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 188
188 HYDROLOGY
(ii) by adding common salt into flowing water and determining its concentration downstream.
(iii) by slope-area method.
(iv) by area-velocity method.
(v) by measuring head over weirs or anicuts.
(vi) by measuring the upstream depth in a standing wave flume.
II Match the items in A with the items in B
A B
(i) Area-velocity method (a) Afflux
(ii) Slope-area method (b) Turbulent streams
(iii) Bridge openings (c) Mean velocity
(iv) Salt-concentration method (d) v = aN + b
(v) Surface and subsurface floats (e) Q = K(h a)
n
(vi) Velocity rods (f) AWLR
(vii) Current-meter rating (g) Control section downstream
(viii) Stage-discharge curve (h) Peak flood where no gauging
station exists
(ix) River stage (i) Current-meter gauging
(x) Stream gauging spite (j) Surface velocity
III Say true or false, if false, give the correct statement:
(i) The staff-gauge reading corresponding to zero-discharge in a stream is always a positive
number.
(ii) The mean velocity in a vertical stream can be calculated by measuring the velocities at one-
fifth and four-fifths of the depth of the stream in that vertical.
(iii) While the surface and subsurface floats measure the mean velocity of the stream, the veloc-
ity rods measure the surface velocity.
(iv) Subsurface floats will not give the velocity accurately since they are affected by wind.
(v) Discharge in a river can not be determined by measurement near bridge openings.
(vi) The salt-concentration method can best be used to determine the discharge of non-turbulent
rivers.
(vii) The hydraulic turbine can be used as a good water meter.
(viii) The stream gauging site should be on the upstream of the confluence of rivers.
(ix) There should be a good-control section immediately upstream of the gauging site.
(x) The calibration of the current meter is called the current meter rating while the stage-dis-
charge is the relation between the staff-gauge reading and the stream discharge.
(xi) If the stage-discharge relation is governed by the slope, size and roughness of the channel
over a considerable distance, the station is under channel control.
(xii) A pressure transducer may be used to obtain:
(a) a stage-hydrograph.
(b) a dischargehydrograph.
(xiii) The slope-area method is often used to estimate peak floods near the existing gauging station.
(false: ii, iv, v, vi, viii, ix, xiii)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 189
STREAM GAUGING 189
OUE8TON8
1 (a) What are the factors that influence the selection of a site for a stream gauging station?
(b) Explain how the stage-discharge-rating curve for a stream-gauging station is prepared. Sketch
a typical rating curve. What are the sources of error in getting the discharge from the rating
curve?
2 (a) What equipment will you use for making velocity measurements in a stream? Explain.
(b) Velocity measurements are to be made at a vertical in a stream. At what height or heights
from the bed, will you make the measurements to determine the mean in vertical velocity by:
(i) one-point method, and (ii) by two-points method?
3 (a) What is a flow rating curve? Explain its use. Sketch a typical flow rating curve.
(b) Following velocities were recorded in a stream with a current meter.
Depth above bed (m): 0 1 2 3 4
Velocity (m/sec): 0 0.5 0.7 0.8 0.8
Find the discharge per unit width of stream near the point of measurement. Depth of flow at
the point was 5 m. (3.75 cumec)
4 (a) Explain briefly the method of stream gauging by area-velocity method.
(b) The following data were collected for a stream at a gauging station. Compute the discharge
by (i) mid-section method (ii) mean-section method.
Distance from one Depth
end of water of Velocity (m/sec)
surface water at 0.6d at 0.2d at 0.8d
(m) (m)
0 0
1.2 0.7 0.4
2.4 1.7 0.7 0.5
3.6 2.5 0.9 0.6
4.8 1.3 0.6 0.4
6.0 0.5 0.35
7.2 0
(4.8, 4.442 cumec)
5 (a) Explain: current metre rating curve. How it is prepared ? Sketch a typical rating curve.
(b) What do you understand by the term control point with reference to a stream gauging
station?
6 The staff gauge readings and the corresponding discharges measured in a stream are given
below. Assuming the relationship to be exponential, fit an equation by drawing a graph. What is
the discharge for a staff gauge reading of 1.6 m and 2.5 m?
Gauge reading (m): 0.40 0.70 1.09 1.28 1.49 1.83 2.32
Discharge (cumec): 24 47 80 98 121 163 268
7 The following data were collected for two verticals in a stream at a gauging station. Compute the
discharge in the elemental strips by
(i) the mid-section method (ii) the mean-section method
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 190
190 HYDROLOGY
Distance from Depth, d Immersion of current meter
one end of (m) below water surface (m)
water surface at 0.2d at 0.8d
(m) rev sec rev sec
3 0.8 135 150 97 151
6 1.2 150 100 150 138
Rating equation of the current meter; v = 0.7 N + 0.03 where N = rev./sec, v = velocity (m/sec).
8 The following data are obtained from the current meter gauging of a stream, at a gauging sta-
tion. Compute the stream discharge.
Distance from one Depth of water, d Immersion of current meter
end of water surface (m) below water surface
(m) depth (m) rev sec
0 0
2 1.0 0.6 10 40
4 2.2 0.44 36 48
1.76 20 50
6 4.0 0.80 40 57
3.20 30 53
8 8.0 1.6 46 59
6.4 33 57
10 4.2 0.84 33 51
3.36 29 49
12 2.5 0.50 34 52
2.00 29 53
14 1.2 0.72 16 48
16 0
Rating equation of current meter: v = 0.2 N + 0.04, where N = rev./sec, v = velocity (m/sec).
9. A surface float took 10 sec to travel a straight run of a stream of 20 m. What is the approximate
mean velocity of the stream? If a velocity rod had been used, what time it would have taken to
travel the same run. (1.7 m/sec, 11.8 sec)
10. (a) What is the effect of rising or falling stage upon the discharge-curve?
(b) The following data are obtained by stream gauging of a river:
Main gauge staff reading (m) 9.6 9.6
Auxiliary gauge staff reading (m) 9.32 8.63
Discharge (cumec) 4.50 8.45
What should be the discharge when the main gauge reads 9.6 m and the auxiliary gauge reads
9.02 m? (6.55 cumec)
11. Write a note on stream gauging with shifting control.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD6-1.PM5 191
STREAM GAUGING 191
12. The cross section (C/S) of a river is as follows:
Distance from BM (m) 0 10 20 30 40 50 60 70
Reduced level on C/S (m) 46.70 44.5 42.80 42.10 42.70 42.70 44.00 46.80
Longitudinal section (L/S) is as follows:
Distance (m) 1 km upstream at bridge site 1 km downstream
HFL along L/S (m) 45.10 44.50 43.89
Mannings n may be assumed as 0.03.
A bridge is proposed across the river. Calculate the high flood discharge at bridge site.
13. A bridge is proposed across a stream which has a catchment area of 3200 km
2
. Ryves coefficient
of C = 10 applies. Compute the maximum flood discharge at bridge site.
14. The following are the measurements at a bridge site, during floods. Compute the maximum flood
discharge at bridge site:
Width of natural water way 284 m
Lineal water way under the bridge 227 m
For rounded entry take C
d
as 0.95
Depth upstream of bridge 4.80 m
Depth downstream of bridge 3.00 m
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 7
7.1 TYPES OF AQUIFERS AND FORMATIONS
Ground water is widely distributed under the ground and is a replenishable resource unlike
other resources of the earth. The problems in Ground Water Investigation are the zones of
occurrence and recharge. The modern trends are to create more opportunity for recharge of
ground water from natural sources like rain, percolation dams, etc. The ground water is free
from pollution and the ground water storage is free from atomic attacks. Ground water can be
developed at a small capital cost in least possible time, and intensive irrigation can be prac-
tised with double and tripple cropping including commercial crops; ground water can be used
for supplemental irrigation during periods of deficient surface supply, for the year-round irri-
gation practice.
A water bearing geologic formation or stratum capable of transmitting water through
its pores at a rate sufficient for economic extraction by wells is called aquifer. Formations that
serve as good aquifers are:
unconsolidated gravels, sands, alluvium
lake sediments, glacial deposits
sand stones
limestones with cavities (caverns) formed by the action of acid waters (solution open-
ings in limestones and dolomites)
granites and marble with fissures and cracks, weathered gneisses and schists
heavily shettered quartzites
vescicular basalts
slates (better than shales owing to their jointed conditions)
A geologic formation, which can absorb water but can not transmit significant amounts
is called an aquiclude. Examples are clays, shales, etc.
A geologic formation with no interconnected pores and hence can neither absorb nor
transmit water is called an aquifuge. Examples are basalts, granites, etc.
A geologic formation of rather impervious nature, which transmits water at a slow rate
compared to an aquifer (insufficient for pumping from wells) is called an aquitard. Examples
are clay lenses interbedded with sand.
Specific yield. While porosity (n) is a measure of the water bearing capacity of the for-
mation, all this water can not be drained by gravity or by pumping from wells as a portion of
water is held in the void spaces by molecular and surface tension forces. The volume of water,
GROUND WATER
192
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 193
GROUND WATER 193
expressed as a percentage of the total volume of the saturated aquifer, that will drain by
gravity when the water table (Ground Water Table (GWT) drops due to pumping or drainage,
is called the specific yield (S
y
) and that percentage volume of water, which will not drain by
gravity is called specific retention (S
r
) and corresponds to field capacity i.e., water holding
capacity of soil (for use by plants and is an important factor for irrigation of crops). Thus,
porosity = specific yield + specific retention
n = S
y
+ S
r
...(7.1)
Specific yield depends upon grain size, shape and distribution of pores and compaction
of the formation. The values of specific yields for alluvial aquifers are in the range of 1020%
and for uniform sands about 30%.
7.2 CONFINED AND UNCONFINED AQUIFERS
If there is homogeneous porous formation extending from the ground surface up to an imper-
vious bed underneath (Fig. 7.1), rainwater percolating down in the soil saturates the forma-
tion and builds up the ground water table (GWT). This aquifer under water table conditions is
called an unconfined aquifer (water-table aquifer) and well drilled into this aquifer is called a
water table well.
Aquiclude
(Impervious)
Bed rock
Confined or artesian
aquifer
2
Confining
layer
W
ater table
aquifer
W.T. Aquifer
2
Imp
layer
Cap. fringe
GWT
S
l
o
p
i
n
g
G
.
S
. 1
W.T.
Precipitation
Recharge area at
outcropping of formation
Piezometric
surface
Flowing artesian
well
Water table
well
Non-flowing
artesian well
Perched
water table
1 Zone of aeration
2 Zone of saturation
Fig. 7.1 Types of aquifers and location of wells
On the other hand, if a porous formation underneath is sandwiched between two imper-
vious strata (aquicludes) and is recharged by a natural source (by rain water when the forma-
tion outcrops at the ground surfacerecharge area, or outcrops into a river-bed or bank) at a
higher elevation so that the water is under pressure in the aquifer (like pipe flow), i.e., artesian
condition. Such an aquifer is called an artesian aquifer or confined aquifer. If a well is drilled
into an artesian aquifer, the water level rises in the well to its initial level at the recharge
source called the piezometric surface. If the piezometric surface is above the ground level at
the location of the well, the well is called flowing artesian well since the water flows out of the
well like a spring, and if the piezometric surface is below the ground level at the well location,
the well is called a non-flowing artesian well. In practice, a well can be drilled through 2-3
artesian aquifers (if multiple artesian aquifers exist at different depths below ground level).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 194
194 HYDROLOGY
Sometimes a small band of impervious strata lying above the main ground water table
(GWT) holds part of the water percolating from above. Such small water bodies of local nature
can be exhausted quickly and are deceptive. The water level in them is called perched water
table.
Storage coefficient. The volume of water given out by a unit prism of aquifer (i.e., a
column of aquifer standing on a unit horizontal area) when the piezometric surface (confined
aquifers) or the water table (unconfined aquifers) drops by unit depth is called the storage
coefficient of the aquifer (S) and is dimensionless (fraction). It is the same as the volume of
water taken into storage by a unit prism of the aquifer when the piezometric surface or water
table rises by unit depth. In the case of water table (unconfined) aquifer, the storage coefficient
is the same of specific yield (S
y
).
Since the water is under pressure in an artesian aquifer, the storage coefficient of an
artesian aquifer is attributable to the compressibility of the aquifer skeleton and expansibility
of the pore water (as it comes out of the aquifer to atmospheric pressure when the well is
pumped) and is given by the relation.
S =
w
nb
1 1
K nE
w s
+
F
H
G
I
K
J
...(7.2)
where S = storage coefficient (decimal)

w
= specific weight of water
n = porosity of soil (decimal)
b = thickness of the confined aquifer
K
w
= bulk modulus of elasticity of water
E
s
= modulus of compressibility (elasticity) of the soil grains of the aquifer.
Since water is practically incompressible, expansibility of water as it comes out of the
pores has a very little contribution to the value of the storage coefficient.
The storage coefficient of an artesian aquifer ranges from 0.00005 to 0.005, while for a
water table aquifer S = S
y
= 0.050.30. The specific yield (unconfined aquifers) and storage
coefficient (confined aquifers), values have to be determined for the aquifers in order to make
estimates of the changes in the ground water storage due to fluctuation in the GWT or
piezometric surface (ps) from the relation.
GWS = A
aq
GWT or ps S or S
y
...(7.3)
where GWS = change in ground water storage
A
aq
= involved area of the aquifer
GWT or ps = fluctuation in GWT or ps
S or S
y
= storage coefficient (confined aquifer) or specific yield (unconfined aquifer).
Example 7.1 In a certain alluvial basin of 100 km
2
, 90 Mm
3
of ground water was pumped in a
year and the ground water table dropped by about 5 m during the year. Assuming no replenish-
ment, estimate the specific yield of the aquifer. If the specific retention is 12%, what is the
porosity of the soil?
Solution (i) Change in ground water storage
GWS = A
aq
GWT S
y
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 195
GROUND WATER 195
90 10
6
= (100 10
6
) 5 S
y
S
y
= 0.18
(ii) Porosity n = S
y
+ S
r
= 0.18 + 0.12 = 0.30. or 30%
Example 7.2 An artesian aquifer, 30 m thick has a porosity of 25% and bulk modulus of
compression 2000 kg/cm
2
. Estimate the storage coefficient of the aquifer. What fraction of this is
attributable to the expansibility of water?
Bulk modulus of elasticity of water = 2.4 10
4
kg/cm
2
.
Solution S =
w
nb

1 1
K nK
w s
+
F
H
G
I
K
J

= 1000 0.25 30
1
2 14 10
1
0 25 2 10
8 7
. .
+

F
H
G
I
K
J
= 7500 (0.467 10
8
+ 20 10
8
) = 1.54 10
3
Storage coefficient due to the expansibility of water as a percentage of S above
=
7500 0 467 10
7500 20 467 10
8
8

.
.
100 = 2.28%, which is negligibe
Note In less compressible formations like limestones for which E
s
2 10
5
kg/cm
2
, S = 5
10
5
and the fractions of this attributable to water and aquifer skeleton are 70% and 30%, respectively.
7.3 DARCYS LAW
Flow of ground water except through coarse gravels and rockfills is laminar and the velocity of
flow is given by Darcys law (1856), which states that the velocity of flow in a porous medium
is proportional to the hydraulic gradient, Fig. 7.2, i.e.,
V = Ki, ...(7.4)
i =
h
L
...(7.4 a)
Q = AV = AKi, A = Wb, T = Kb ...(7.4 b)
Q = WbKi ...(7.4 c)
Q = T iw ...(7.5)
Aquiclude
(Impervious)
G
.
W
.
F
l
o
w
Artesian K
aquifer

b
Q
A = wb
Aquiclude
(Imp.)

h
h
L
i =
h.g.L.
G
.S
.
Recharge
area
P
Recharge
by rain
Piezometers or
drilled wells
(HGL) - Hydraulic Gradient Line (HGL) or piezometric surface
Q = KAi, A = wb, T = kb
\Q = Tiw
L
Fig. 7.2 Flow of ground water
where V = velocity of flow through the aquifer
K = coefficient of permeability of aquifer soil
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 196
196 HYDROLOGY
i = hydraulic gradient
=
h
L
, h = head lost in a length of flow path L
A = cross-sectional area of the aquifer (= wb)
w = width of aquifer
b = thickness of aquifer
T = coefficient of transmissibility of the aquifer
Q = volume rate of flow of ground water (discharge or yield)
Darcys law is valid for laminar flow, i.e., the Reynolds number (R
e
) varies from 1 to 10,
though most commonly it is less than 1
R
e
=

Vd
1 ...(7.6)
where = mass density of water
= dynamic viscosity of water
d = mean grain size of the aquifer soil
In aquifers containing large diameter solution openings, coarse gravels, rockfills and
also in the immediate vicinity of a gravel packed well, flow is no longer laminar due to high
gradients and exhibit non linear relationship between the velocity and hydraulic gradient. For
example, in a gravel-packed well (mean size of gravel 5 mm) R
e
45 and the flow would be
transitional at a distance of about 5 to 10 times the well radius.
7.4 TRANSMISSIBILITY
It can be seen from Eq. (7.5) that T = Q, when i = 1 and w = 1; i.e., the transmissibility is the
flow capacity of an aquifer per unit width under unit hydraulic gradient and is equal to the
product of permeability times the saturated thickness of the aquifer. In a confined aquifer, T =
Kb and is independent of the piezometric surface. In a water table aquifer, T = KH, where H is
the saturated thickness. As the water table drops, H decreases and the transmissibility is
reduced. Thus, the transmissibility of an unconfined aquifer depends upon the depth of GWT.
7.5 WELL HYDRAULICS
Steady radial flow into a well (Dupuit 1863, Thiem 1906)
(a) Water table conditions (unconfined aquifer)
Assuming that the well is pumped at a constant rate Q for a long time and the water
levels in the observation wells have stabilised, i.e., equilibrium conditions have been reached,
Fig. 7.3 (a).
From Darcys law, Q = K i A
Q = K
dy
dx
(2 xy)
Q
r
r
dx
x
1
2
z
= 2 K
y dy
h
h
1
2
z
Q =
K h h
r
r
( )
. log
2
2
1
2
10
2
1
2 303

F
H
G
I
K
J
...(7.7)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 197
GROUND WATER 197
x
Cone of
drawdown
P.W.L.
T = KH
Homogeneous
aquifer K
Well screen
(Strainer)
Bail plug
h
w
h
1
y
P
s
1
s
w dW
2 r
w
s
2
h
2
H
a. Well in a water table aquifer
Aquiclude
(Imp.)
GWT. (Non-pumping)
G.S.
Q
PW
R
r
2
r
1 1 2
Impermeable
(Aquiclude)
Bail plug
Confined or
b artesian aquifer K
Well screen
(Strainer)
T = kb
b. Well in a confined aquifer
H h
2 h
1
h
w
s
w
s
1
s
2
y
x
x

y
Cone of drawdown
Aquiclude
(Impermeable)
P.W.L.
Non - pumping
piezometric surface
2 r
w
GS
Q
PW
R
r
2
r
1 1 2
R: Radius of influence
1,2: Observation wells
PW: Pumping well
dw: Dewatered zone
R: Radius of influence
1,2: Observation wells
PW: Pumping well
P
Dy
Dx
Fig. 7.3 Steady radial flow into a well
Applying the Eq. (7.7) between the face of the well (r = r
w
, h = h
w
) and the point of zero-
drawdown (r = R, h = H)
Q =
K H h
R
r
w
( )
. log
2 2
10
2 303

F
H
G
I
K
J
...(7.7 a)
If the drawdown in the pumped well (s
w
= H h
w
) is small
H
2
h
w
2
= (H + h
w
) (H h
w
), H + h
w
2H
= 2H (H h
w
)
Then, Q =
2
2 303
10
KH H h
R
r
w
w
( )
. log

F
H
G
I
K
J
, KH = T
Q =
272
10
. ( )
log
T H h
R
r
w
w

F
H
G
I
K
J
...(7.8)
(b) Artesian conditions (confined aquifer)
If the well is pumped at constant pumping rate Q for a long time and the equilibrium
conditions have reached, Fig. 7.3 (b).
From Darcys law, Q = K i A
Q = K
dy
dx
(2 xb)
Q
r
r
dx
x
1
2
z
= 2 Kb
h
h
1
2
z
dy
Q =
2
2 303
2 1
10
2
1
( ) ( )
. log
kb h h
r
r

F
H
G
I
K
J
...(7.9)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 198
198 HYDROLOGY
Applying Eq. (7.9) between the face of the well (r = r
w
, h = h
w
) and the point of zero-
drawdown (r = R, h = H), simplifying and putting T = Kb,
Q =
272
10
. ( )
log
T H h
R
r
w
w

F
H
G
I
K
J
...(7.10)
which is the same as Eq. (7.8) (for water table conditions under small drawdown).
Note The length of screen provided will be usually half to three-fourths of the thickness of the
aquifer for obtaining a suitable entrance velocity ( 2.5 cm/sec) through the slots to avoid incrustation
and corrosion at the openings; the percentage open area provided in the screen will be usually 15 to
18%.
Dupuits Equations Assumptions
The following assumptions are made in the derivation of the Dupuit Thiem equations:
(i) Stabilised drawdowni.e., the pumping has been continued for a sufficiently long
time at a constant rate, so that the equilibrium stage of steady flow conditions have
been reached.
(ii) The aquifer is homogeneous, isotropic, of infinite areal extent and of constant thick-
ness, i.e., constant permeability.
(iii) Complete penetration of the well (with complete screening of the aquifer thickness)
with 100% well efficiency.
(iv) Flow lines are radial and horizontal and the flow is laminar, i.e., Darcys law is
applicable.
(v) The well is infinitely small with negligible storage and all the pumped water comes
from the aquifer.
The above assumptions may not be true under actual field conditions; for example, if
there is no natural source of recharge nearby into the aquifer, all the pumped water comes
from storage in the aquifer resulting in increased drawdowns in the well with prolonged pumping
and thus the flow becomes unsteady (transient flow conditions). There may be even leakage
through the overlying confining layer (say, from a water table aquifer above the confining
layer) of an artesian aquifer (leaky artesian aquifer). The hydraulics of wells with steady and
unsteady flow under such conditions as developed from time to time by various investigators
like Theis, Jacob, Chow, De Glee, Hantush, Walton, Boulton etc. have been dealt in detail in
the authors companion volume Ground Water published by M/s Wiley Eastern Limited New
Delhi and the reader is advised to refer the book for a detailed practical study of Ground Water
dealing with Hydrogeology, Ground Water Survey and Pumping Tests, Rural Water Supply
and Irrigation Systems. For example, in the Theis equation for unsteady radial flow into a well
it is assumed that the water pumped out is immediately released from storage of the aquifer
(no recharge) as the piezometric surface or the water table drops. But in unconfined aquifers
and leaky artesian aquifers (that receive water from upper confining layer with a free water
table), the rate of fall of the water table may be faster than the rate at which pore water is
released; this is called delayed yield as suggested by Boulton.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 199
GROUND WATER 199
7.6 SPECIFIC CAPACITY
The specific capacity
Q
S
w
of a well is the discharge per unit drawdown in the well and is
usually expressed as lpm/m. The specific capacity is a measure of the effectiveness of the well;
it decreases with the increase in the pumping rate (Q) and prolonged pumping (time, t).
In Eq. (7.8) by putting r
w
= 15 cm, R = 300 m, Hh
w
= S
w
, the specific capacity
Q
S
w

T
12 .
, in consistent units ...(7.11)
Example 7.3 A 20-cm well penetrates 30 m below static water level (GWT). After a long period
of pumping at a rate of 1800 lpm, the drawdowns in the observation wells at 12 m and 36 m
from the pumped well are 1.2 m and 0.5 m, respectively.
Determine: (i) the transmissibility of the aquifer.
(ii) the drawdown in the pumped well assuming R = 300 m.
(iii) the specific capacity of the well.
Solution Dupuits Eq. (7.7): Q =
K h h
r r
( )
. log /
2
2
1
2
10 2 1
2 303

h
2
= H s
2
= 30 0.5 = 29.5 m; h
1
= H s
1
= 30 1.2 = 28.8 m
1.800
60
=
K( . . )
. log /
29 5 28 8
2 303 36 12
2 2
10

K = 2.62 10
4
m/sec or 22.7 m/day
(i) Transmissibility T = KH = (2.62 10
4
) 30 = 78.6 10
4
m
2
/sec,
or = 22.7 30 = 681 m
2
/day
(ii) Eq. (7.8): Q =
2 72
10
. ( )
log /
T H h
R r
w
w


1800
60
.

272 78.6 10
300 0 10
4
10
. ( )
log / .


S
w
drawdown in the well, S
w
= 4.88 m
(iii) The specific capacity of the well
=
Q
S
w
=
1800
60 4 88
.
.
= 0.0062 (m
3
sec
1
/m)
or 372 Ipm/m

Q
S
w

T
12 .
=
78 6 10
12
4
.
.


= 0.00655 (m
2
sec
1
/m)
or 393 lpm/m
Example 7.4 A tube well taps an artesian aquifer. Find its yield in litres per hour for a drawdown
of 3 m when the diameter of the well is 20 cm and the thickness of the aquifer is 30 m. Assume
the coefficient of permeability to be 35 m/day.
If the diameter of the well is doubled find the percentage increase in the yield, the other
conditions remaining the same. Assume the radius of influence as 300 m in both cases.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 200
200 HYDROLOGY
Solution Dupuits Eq. (7.10): Q =
2 72
10
. ( )
log /
T H h
R r
w
w

=
2 72 35 24 30 3
300 0 10
10
. {( / ) }
log ( / . )

= 102.7 m
3
/hr
or = 102700 lph
The yield Q
1
log ( / ) R r
w
...(7.12)
other things remaining same.
If the yield is Q after doubling the diameter, i.e.,
r
w
= 0.10 2 = 0.20 m

Q
Q
=
log /
log /
R r
R r
w
w
log
300
0 10 .
= 3.4771, log
300
0 20 .
= 3.1761

1027 .
Q
=
3 1761
3 4771
.
.
Q = 112.4 m
3
/hr
percentage increase in yield =
Q Q
Q
100 =
112 4 1027
102 4
. .
.

100 = 9.45%
Thus, by doubling the diameter the percentage in yield is only about 10%, which is
uneconomical. Large diameter wells necessarily do not mean proportionately large yields. The
diameter of a tube well usually ranges from 20 to 30 cm so that the bowl assembly of a deep
well or a submersible pump can easily go inside with a minimum clearance.
Refer Appendix-D for Unsteady Groundwater Flow.
7.7 CAVITY WELLS
If a relatively thin impervious formation or a stiff clay layer is encountered at a shallow depth
underlain by a thick alluvial stratum, then it is an excellent location for a cavity well. A hole
is drilled using the hand boring set and casing pipe is lowered to rest firmly on the stiff clay
layer, Fig. 7.4. A hole of small cross-section area is drilled into the sand formation and is
developed into a big hollow cavity by pumping at a high rate or by operating a plunger giving
a large yield. The depth of the cavity at the centre varies from 15-30 cm with 6-8 m radius of
the cavity. The flow of water into the cavity is spherical and the yield is low. The failure of a
cavity well is usually due to caving of the clay roof. Since the depth is usually small, deep well
pumps are not necessary and thus the capital costs of construction, development and installa-
tion of pumpset of a cavity well are low.
Yield of Cavity Well
For the unsteady flow condition, the pumping rate Q of a cavity well is given by
s =
Q S
K t
Q
kr
s
6 2
+ ...(7.13)
where s = drawdown in the observation well at a distance r from the cavity well
Q = constant pumping rate
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 201
GROUND WATER 201
Cavity y
Sand layers free
from fine grains
Extensively thick
confined aquifer
Flow spherical
critical velocity
surface
Aquiclude (Imp.)
r
e
h
w
Stiff clay
layer (Imp.)
R
H
o
+
Weathered
soil
Piezometric surface
Casing
Non-pumping Top soil
Q
GS
r
w
PWL
Fig. 7.4 Flow into a cavity well
S
s
= specific storage coefficient (i.e., for unit aquifer thickness)
K = permeability of the aquifer
t = time since pumping began
For steady state flow condition, the well yield is given by
Q =
2
1
Ky H h
r R
w
w
( )
/

...(7.14)
and the width of the cavity, Fig. 7.4
r
e
= ( ) 2r y y
w
...(7.15)
where y = depth of cavity (at the centre)
r
w
= radius of cavity
R = radius of influence
Example 7.5 The following data are obtained from a cavity tube well:
Discharge 30 lps
Drawdown 4 m
Permeability of the aquifer 50 m/day
Depth of cavity 20 cm
Radius of influence 150 m
Determine the radius and width of cavity.
Solution Well yield Q =
2
1
Ky H h
r
R
w
w
( )

30
1000
= 2
50
24 60 60
0 20 4
1
150


.
r
w
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 202
202 HYDROLOGY
Radius of cavity, r
w
= 135.5 m
Width of cavity, r
e
= ( ) 2r y y
w
= ( . . ) . 2 4 5 0 2 0 2 = 7.36 m
7.8 HYDRAULICS OF OPEN WELLS
Theis equation does not apply for shallow dug open wells since there is no instantaneous re-
lease of water from the aquifer, most of the water being pumped only from storage inside the
well (Fig. 7.5).
GS
SWL
Recuperated
water level
Recuperated
in time T
Depressed
water level
Impervious well
steining
Flow into well
S
2
S
1
Fig. 7.5 Recuperation test in open wells
In alluvial soil, if the water is pumped at a high rate the depression head (static water
levelwater level inside the well during pumping) will increase, which may cause excess gradi-
ents resulting in loosening of sand particles (quick sand phenomenon). This limiting head is
called critical depression head. The safe working depression head is usually one-third of the
critical head and the yield under this head is called the maximum safe yield of the well.
Yield Tests
The following tests may be performed to get an idea of the probable yield of the well:
(a) Pumping test
(b) Recuperation test
(a) Pumping Test. In the pumping test, the water level in the well is depressed to an
amount equal to the safe working head for the sub-soil. Then the water level is kept constant
by making the pumping rate equal to the percolation into the well. The quantity of water
pumped in a known time gives an idea of the probable yield of the well of the given diameter.
The test may be carried out in an existing open well.
In hard-rock areas,
if D = diameter of the well
d = depth of water column
Q = pumping rate
t = time required for emptying the well
then,
Rate of seepage into the well
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 203
GROUND WATER 203
=
Volume of water pumped out Volume of water stored in the well
Time of pumping

=
Qt
D
d
t

2
4
...(7.16)
(b) Recuperation Test. In the recuperation test, the water level in the well is depressed
by an amount less than the safe working head for the subsoil. The pumping is stopped and the
water level is allowed to rise or recuperate. The depth of recuperation in a known time is noted
from which the yield of the well may be calculated as follows (Fig. 7.5).
Let the water level inside the well rise from s
1
to s
2
(measured below static water level,
swl) in time T. If s is the head at any time t, from Darcys law
Q = KAi
if a head s is lost in a length L of seepage path
Q = KA
s
L
Q = CAs
where the constant C =
K
L
and has dimensions of T
1
.
If in a time dt, the water level rises by an amount ds
Q dt = A ds
the ve sign indicates that the head decreases as the time increases.
Putting Q = CAs
CAs dt = A ds
C
0
T
dt
z
=
s
s
ds
s
1
2
z

C =
2 303 .
T
log
10

s
s
1
2
...(7.17)
Assuming the flow is entirely from the bottom (impervious steining of masonry), the
yield of the well
Q = CAH ...(7.17a)
where Q = safe yield of the well
A = area of cross section of the well
H = safe working depression head
C = specific yield of the soil
From Eq. (7.17a) Q = C when A = 1, H = 1, i.e., the specific yield of the soil is the
discharge per unit area under a unit depression head and has dimension of T
1
(1/time) and
the usual values are
C = 0.25 hr
1
for clayey soil
C = 0.50 hr
1
for fine sand
C = 1.00 hr
1
for coarse sand
The value of C is usually determined from a recuperation test, (Eq. (7.17)).
Example 7.6 A well of size 7.70 4.65 m and depth 6.15 m in lateritic soil has its normal
water level 5.08 m below ground level (bgl). By pumping for 1
1
2
hours, the water level was
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 204
204 HYDROLOGY
depressed to 5.93 m bgl and the pumping was stopped. The recuperation rates of the well dur-
ing 4 hours after the pumping stopped are given below. The total volume of water pumped
during 1
1
2
hours of pumping was 32.22 m
3
. (no well steining is provided)
Recuperation rates
Time since
pumping stopped Water level bgl
(min) (m)
0 5.930
15 5.890
30 5.875
45 5.855
60 5.840
90 5.820
120 5.780
180 5.715
240 5.680
Determine
(i) Rate of seepage into the well during pumping.
(ii) Specific yield of the soil and specific capacity of the well.
(iii) Yield of the well under a safe working depression head of 0.85 m.
(iv) The area of crop that can be irrigated under the well (assume a peak consumptive use
of 4 mm and irrigation efficiency of 75%).
(v) Diameter of the well in such a soil to get an yield of 3000 lph under a safe working
depression head of 0.8 m.
Solution (i) Seepage into the wellfrom pumping data:
Volume of water pumped out = 32.22 m
3
Volume of water stored in the well (that was pumped out)
= (7.70 4.65) (5.93 5.08) = 30.5 m
3
Rate of seepage into the well
=
32.22 30.5
1.5

= 1.15 m
3
/hr
(ii) Specific yield of the soil
C =
2303 .
T
log
10

s
s
1
2
=
2303
4
.
log
10

5 93 5 08
5 68 508
. .
. .

= 0.09 hr
1
(or m
3
/hr per m drawdown)
Specific capacity of the well is its yield per unit drawdown
Q = CAH
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 205
GROUND WATER 205
Specific capacity = Q/H = CA = 0.09 (7.70 4.65)
= 3.58 m
3
hr
1
/m (or m
2
/hr)
(iii) Safe yield of the well
Q = CAH = 0.09 (7.70 4.65) 0.85 = 3.04 m
3
/hr
which is more than twice the seepage into the well during pumping.
(iv) Area of crop that can be irrigated under the well:
Data to draw the curve s
1
/s
2
vs. t (s
1
= total drawdown, s
2
= residual drawdown): SWL =
5.08 m, s
1
= 5.93 5.08 = 0.85 m
Time since Water level Residual drawdown
pumping stopped bgl s
2
= wL SWL Ratio (s
1
/s
2
)
t (min) (m) (m)
0 5.930 0.850 (= s
1
) 1.00
15 5.890 0.810 1.05
30 5.875 0.795 1.07
45 5.855 0.775 1.09
60 5.840 0.760 1.11
90 5.820 0.740 1.15
120 5.780 0.700 1.21
180 5.715 0.635 1.33
240 5.680 0.600 1.41
From the plot of s
1
/s
2
vs. time on a semi-log paper (Fig. 7.6), it is seen that s
1
/s
2
= 9.5
after 24 hours of recovery (by extending the straight line plot), and the residual drawdown
after 24 hours, s
24
=
085
9 5
.
.
0.09 m; hence the depth of recuperation per day = 0.85 0.09 = 0.76
m and the volume of water available per day (7.70 4.65) 27.2 m
3
. With an average peak
consumptive use of 4 mm for the type of crops grown and irrigation efficiency of 75%, the area
of crop (A
crop
) that can be irrigated under one well in lateritic soils is
4
1000 075 .
A
crop
= 27.2
A
crop
= 5100 m
2
or 0.5 ha
(v) Diameter of the well to yield 3000 lph:
Q = CAH

3000
1000
= 0.09
D
2
4
0.8
D = 7.3 m, which is too big
It may be noted that it is not advisable to go deeper in these areas otherwise salt water
instrusion takes place.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 206
206 HYDROLOGY
Well dug in lateritic
soil near Mangalore
L B D
= 7.70 4.65 6.15 m


(KREC)
Semi-log paper
E
x
t
r
a
p
o
l
a
t
e
d
Observed
data
10
9
8
7
6
5
4
3
2
1.5
S
S
1
2
= 9.5
1
0 2 4 6 8 10 12 14 16 18 20 22 24
Recuperation time t (hr)
R
a
t
i
o
SS
12
Fig. 7.6 Plot of recuperation test data (Example 7.6)
7.9 CONSTRUCTION OF OPEN WELLS
In alluvial soil, where an impervious vertical steining is provided to support the soil, percola-
tion into the well is entirely from the bottom and depends on the area of cross-section of the
well. Bigger diameter wells are recommended in such soil to give larger yields. In case of wells
in rocky substrata with fissures and cracks, the lower portion of the steining may be provided
with alternate bands of masonry laid dry (i.e., without cement mortar) (Fig. 7.7), and the
percolation into the well is mostly from the sides through fissures and cracks in the weathered
rock. In such wells, higher yields are obtained by going deeper, as long as the weathering and
fractures are evident rather than making the wells wider or larger diameter. Larger diameter
wells also involve large volume of excavation in rocks and the mounds of excavated rock depos-
ited on the ground surface occupy considerable area of cultivable land. Sometimes, it is pro-
posed to widen when it is felt that such widening will, include some well-defined fissures and
fractures.
Some of the existing wells may be revitalised by deepening by blasting; vertical bores
may be drilled at the bottom of the well when it is felt it will tap some layer under pressure,
i.e., a dug-cum-borewell (Fig. 7.8), with a centrifugal pump kept at the bottom of the open well
and the suction pipe lowered inside the bore, thus reducing the suction lift and saving the costs
involved in deep well turbine pump or submersible pump installations in drilled deep wells
from the ground surface. Lateral bores horizontal or inclined, may be drilled in the direction of
certain well-defined fractures yielding water.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 207
GROUND WATER 207
GS
D
d
NPWL
PWL
RCC Curb
Weep holes
Vertical tie rods
Flat iron rings
Foot valve
Flow into well
Centrifugal
pump & motor
Aquifer
Q
Fig. 7.7 Open well construction
Very hard rock
Coarse sand
Hard rock
Bore drilled
Water
Weathered
rock
Dug well
Well-steining
Top soil
GS
Fig. 7.8 Dug-cum-borewell
7.10 SPACING OF WELLS
Pumping wells should be spaced far apart so that their cones of depression will not overlap
over each other resulting in the reduction of their yields and/or increased drawdowns (Fig.7.9),
i.e., to avoid well interference, the wells should be spaced beyond their radii of influence. This
is roughly estimated to be around 6001000 m in alluvial area and around 100200 m in hard
rock areas.
An open dug well should be located beyond the cone of depression of the tubewell; other-
wise when the tubewell is pumping, it will dewater the open well. The open well can get water
only when the tubewell pumping is stopped and fast recuperation takes place.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 208
208 HYDROLOGY
Wells closely spaced in
homogeneous
aquifer
Spacing of
wells
Interference
of cones
Cones of drawdown
PWL
Increased drawdown due
to interference
dw dw
dw dw
PWL
GS
PW
Q
PW
Q
SWL (NPWL)
Dug well
becomes dry
dw: Dewatered zone
PW: Pumped wells
Fig. 7.9 Well interference
OUZ V
I Choose the correct statement/s in the following:
1 The underground formations, which serve as good aquifers are in the order:
(i) consolidated formations of clays and shales
(ii) rock with no signs of weathering or fractures
(iii) rock with fissures and cracks (iv) cavernous lime stones
(v) sand stones (vi) vescicular basalts
(vii) unconsolidated gravels, sands and alluvium
2 The soil properties characteristic of good water yield are:
(i) porosity (ii) permeability
(iii) specific yield (iv) storage coefficient
(v) transmissibility (vi) uniformity coefficient > 3
(vii) uniformity coefficient < 2 (viii) effective size > 0.1 mm
(ix) Reynolds number > 10 (x) specific capacity of the well > 30 lpm/m
(xi) all the above characteristics (1-except i, ii, 2 ii, iii, iv, v, viii, x)
II Match the items in A with the items in B:
A B
(i) Ground water flow (a) Recuperation test
(ii) Unconsolidated alluvium (b) Bore at the bottom of open well
(iii) Aquiclude (c) Lateral or vertical bores
(iv) Specific yield (S
y
) (d) Well spacing
(v) Confined aquifer (e) n S
r
(vi) Storage coefficient (f) Artesian
(vii) Transmissibility (T) (g) f(K
w
, E
s
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 209
GROUND WATER 209
(viii) Rate of ground water flow (Q) (h) KH or Kb
(ix) Reynolds number (R
e
) (i) T iW
(x) Dupuits equation (j) vd/
(xi) Specific capacity (k)
Q
sw
T

12 .
(xii) Open well (l) Stabilised drawdown
(xiii) Well revitalisation (m) Clay
(xiv) Dug-cum-borewell (n) Aquifer
(xv) Well interference (o) Darcys law
III Say true or false; if false, give the correct statement:
(i) The transmissibility of a confined aquifer depends upon the depth of the water table while
that of the water table aquifer does not.
(ii) The available yield of a tube well can be doubled by doubling the diameter.
(iii) The specific yield of an aquifer may be more than its porosity.
(iv) Storage coefficient is the same as specific yield for a water table aquifer.
(v) Flow in a medium sand aquifer is entirely laminar.
(vi) Plants usually extract water from the capillary zone (the intermediate belt or vadose zone).
(false: i, ii, iii)
OUE8TON8
1 (a) Define transmissibility and storage coefficient of an aquifer.
(b) Calculate the discharge from a tubewell of 20-cm diameter penetrating fully into a confined
aquifer of 20-m thick and having a permeability of 40 m/day. The drawdown in the well is
3 m and zero drawdown at 300 m from the well.
If the diameter of the well is doubled, find the percentage increase in the yield, the other
conditions remaining the same.
State the assumptions in the formula you use. (1303.7 lpm)
2 A tubwell penetrates fully an unconfined aquifer. Calculate the discharge from the well in lpm
from the following data:
Diameter of the well 30 cm
Drawdown in the well 3 m
Effective length of the strainer under the above
drawdown 10 m
Coefficient of permeability of the aquifer 40 m/day
Radius of zero drawdown 300 m
3 A 20-cm well penetrates 25 m below the static water table. After 24 hours of pumping out at the
rate of 800 lpm, the water level in a test well at 80 m from the pumping well is lowered by 0.53
m and in a test well 20 m away 2.11 m. Find the coefficient of transmissibility of the aquifer.
4 (a) What is the nature of ground water flow? State the law governing the flow with limitations,
if any.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 210
210 HYDROLOGY
(b) In an area of 100 ha, the water table dropped by 4.5 m due to continuous ground water
pumping. If the porosity of the aquifer soil is 26% and the specific retention is 10 per cent,
determine:
(i) the specific yield of the aquifer.
(ii) the decrease in the ground water storage. (16%, 72 ham)
5 In a certain alluvial basin of 120 km
2
, 100 Mm
3
of ground water was pumped in a year and the
ground water table dropped by 5 m during the year. Assuming no replenishment, estimate the
specific yield of the aquifer. If the specific retention is 12%, what is the porosity of the soil?
(16.7%, 28.7%)
6 An artesian aquifer 25-m thick has a porosity of 17% and bulk modulus of compression 2400 kg/
cm
2
. Estimate the storage coefficient of the aquifer. What fraction of this is attributable to the
expansibility of water ?
Bulk modulus of elasticity of water = 2.14 10
4
kg/cm
2
. (0.00106, 1.87%)
7 A well penetrates into an unconfined aquifer having a saturated depth of 50 m. The discharge is
250 1pm at 8 m drawdown. What would be the discharge at 10 m drawdown. The radius of
influence in both the cases may be taken as same.
8 (a) Explain: the water balance of a catchment.
(b) In a given year over 60 km
2
catchment, 120 cm of rainfall was received and 1000 ha-m was
discharged through the outlet. The ground water table rose by 30 cm and the average specific
yield of the soil was 18%. The soil moisture increased by 5 cm on an average. Estimate the
evapotranspiration during the year. (93 cm)
9 (a) Describe the method of construction of open wells
(i) in a soil where a clayey stratum is encountered.
(ii) in rocky sub-strata.
(b) A well of size 6.60 4.05 m and depth 4.7 m in the lateritic soil near Mangalore (west coast
of India) has its normal water level at 3.825 m below ground level (bgl). By pumping for 1
1
2
hours, the water level (bgl) was depressed to 4.525 m and the pumping was stopped. The
recuperation rates of the well during 2
1
2
hours after the pumping stopped are given below.
The total volume of water pumped during 1
1
2
hours of pumping was 28.87 m
3
(no well steining
is provided)
Recuperation rates
Time since pumping Water level, bgl
stopped (min) (m)
0 4.525
10 4.365
20 4.245
30 4.135
40 4.075
50 4.015
60 3.985
70 3.960
80 3.950
90 3.935
120 3.920
150 3.902
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD7-1.PM5 211
GROUND WATER 211
Determine
(i) Rate of seepage into the well during pumping
(ii) Specific yield of the soil and specific capacity of the well
(iii) Yield of the well under a safe working depression head of 0.7 m
(iv) The area of crop that can be irrigated under the well, assuming a peak consumptive use of
4 mm and irrigation efficiency of 75%.
(v) Diameter of the well in such a soil to get an yield of 3000 lph under a safe working depression
head of 0.7 m (note that it is not advisable to go deeper in these areas lest salt water intru-
sion may not take place).
10 In a recuperation test, the static water level in an open well was depressed by pumping by 3 m
and it recuperated 1.5 m in 1 hour. If the diameter of the well is 3 m and the safe working
depression head is 2.4 m, find the average yield of the well in lpm. What area of crop can come
under this well assuming a peak consumptive use of 5 mm and irrigation efficiency of 75%?
11 Determine the diameter of an open well in coarse sand to give an average yield of 200 lpm under
a safe working depression head of 2.5 m (Hint: for coarse sand C 1 hr
1
).
12 Distinguish between:
(i) Specific capacity of a well and specific yield of an aquifer
(ii) Aquifer and acuiclude
(iii) Open wells and tube wells
(iv) Water table and artesian aquifers
(v) Drainage divide and ground water divide
13 Write short notes on:
(i) Well development (ii) Well spacing
(iii) Radius of influence (iv) Validity of Darcys law
(v) Dug-cum-borewell (vi) Well revitalisation
(vii) Well interference (viii) Recuperation test for open well
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
8.1 SIZE OF FLOODS
A flood is an unusual high stage of a river due to runoff from rainfall and/or melting of snow in
quantities too great to be confined in the normal water surface elevations of the river or stream,
as the result of unusual meteorological combination.
The maximum flood that any structure can safely pass is called the design flood and is
selected after consideration of economic and hydrologic factors. The design flood is related to
the project feature; for example, the spillway design flood may be much higher than the flood
control reservoir design flood or the design flood adopted for the temporary coffer dams. A
design flood may be arrived by considering the cost of constructing the structure to provide
flood control and the flood control benefits arising directly by prevention of damage to structures
downstream, disruption communication, loss of life and property, damage to crops and under-
utilisation of land and indirectly, the money saved under insurance and workmens
compensation laws, higher yields from intensive cultivation of protected lands and elimination
of losses arising from interruption of business, reduction in diseases resulting from inundation
of flood waters. The direct benefits are called tangible benefits and the indirect benefits are
called intangible benefits. The design flood is usually selected after making a cost-benefit analysis
and exercising engineering judgement.
When the structure is designed for a flood less than the maximum probable, there exists
a certain amount of flood risk to the structure, nor is it economical to design for 100% flood
protection. Protection against the highest rare floods is uneconomical because of the large
investment and infrequent flood occurrence.
In the design flood estimates, reference is usually made to three classes:
(a) Standard Project Flood (SPF). This is the estimate of the flood likely to occur from
the most severe combination of the meteorological and hydrological conditions, which are rea-
sonably characteristic of the drainage basin being considered, but excluding extremely rare
combination.
(b) Maximum Probable Flood (MPF). This differs from the SPF in that it includes the
extremely rare and catastrophic floods and is usually confined to spillway design of very high
dams. The SPF is usually around 80% of the MPF for the basin.
(c) Probable Maximum Precipitation (PMP). From the observations of air moisture from
the maximum due-point and temperature recorded and air-inflow (from the wind speed and
barometric pressure recorded), the moisture inflow index in the storm is determined. The best
known upward adjustment to be applied to the historical and hypothetical major storms is the
Chapter 8
FLOODS-ESTIMATION AND CONTROL
212
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 213
FLOODS-ESTIMATION AND CONTROL 213
maximisation with respect to moisture charge. The adjusted storm rainfall is assumed to bear
the same ratio to the observed storm rainfall, as the maximum moisture charge over the basin
to the moisture charge of the observed storm. From the critical combinations of storms, and
moisture adjustment the PMP is derived which, after minimising losses, when applied on the
design unit hydrograph for the basin, will produce the MPF. Occasionally when enough storm
data for the given basin is not available, PMP can be estimated by adopting a severe storm
over neighbouring catchment (which is meteorologically homogeneous) and transposing it to
the catchment under consideration.
(d) Design FloodIt is the flood adopted for the design of hydraulic structures like
spillways, bridge openings, flood banks, etc. It may be the MPF or SPF or a flood of any desired
recurrence interval depending upon the degree of flood protection to be offered and cost eco-
nomics of construction of structures to the desired flood stage; the design flood is usually se-
lected after making a cost-benefit analysis, i.e., the ratio of benefit to cost may be desired to be
the maximum.
8.2 ESTIMATION OF PEAK FLOOD
The maximum flood discharge (peak flood) in a river may be determined by the following
methods:
(i) Physical indications of past floodsflood marks and local enquiry
(ii) Empirical formulae and curves (iii) Concentration time method
(iv) Overland flow hydrograph (v) Rational method
(vi) Unit hydrograph (vii) Flood frequency studies
The above methods are discussed below:
(i) Observations at nearby structure. By noting the flood marks (and by local enquiry),
depths, affluxes (heading up of water near bridge openings, or similar obstructions to flow)
and other items actually at an existing bridge, on anecut (weir) in the vicinity, the maximum
flood discharge may be estimated. The flood marks are connected by levelling, the profile is
plotted and HFL marked on it, and the cross sectional area is determined. The surface fall at
HFL is calculated from the difference in HFL at known distance apart. It may be checked with
the bed slope; there should not be much disparity between the two. By assuming a suitable
value of Mannings n for the nature (roughness) of bed and sides of the river, the velocity may
be determined by Mannings or Chezys formula and the flood discharge estimated, see
example 6.4.
(ii) Empirical Flood Formulae
1. Dickens formula for moderate size basins of north and central India
Q = CA
3/4
...(8.1)
the coefficient C = 1114, where the aar is 60120 cm
= 1419 in Madhya Pradesh
= 32 in western Ghats
up to 35, maximum value
2. Ryves formula derived from a study of rivers in south India
A = CA
2/3
...(8.2)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 214
214 HYDROLOGY
Coefficient C = 6.8 within 80 km of coast
= 8.3 for areas between 80 and 2400 km from the coast
= 10.0 for limited area near the hills
up to 40, actual observed values
3. Inglis formula for fan-shaped catchments of Bombay state (Maharashtra)
Q =
124
10 4
A
A + .
...(8.3)
4. Myers formula Q = 175 A ...(8.4)
5. Ali Nawab Jang Bahadur formula for the old Hyderabad state
Q = CA
(0.993 1/14 log A)
...(8.5)
the coefficient C varies from 48 to 60
Maximum value of C = 85
6. Fullers formula (1914)
Q = CA
0.8
(1 + 0.8 log T
T
)(1 + 2.67 A
0.3
) ...(8.6)
constants derived from the basins in USA 10 years data is required for sufficient
reliability. The coefficient C varies from 0.026 to 2.77; T = recurrence interval in
years. Fuller was the first to suggest that frequency should be considered as a factor
in estimating floods.
7. Greagers formula for USA
Q = C( . )
( )
.
0 386
0.894 0.386
0 048
A
A

...(8.7)
the coefficient C 130 (140.5 for areas most favourable to large floods)
8. Burkli Ziegler formula for USA
Q = 412 A
3/4
...(8.8)
In all the above formula, Q is the peak flood in cumec and A is the area of the drainage
basin in km
2
.
(iii) Envelope Curves. Areas having similar topographical features and climatic condi-
tions are grouped together. All available data regarding discharges and flood formulae are
compiled along with their respective catchment areas. Peak flood discharges are then plotted
against the drainage areas and a curve is drawn to cover or envelope the highest plotted points.
Envelope curves are generally used for comparison only and the design floods got by other
methods, should be higher than those obtained from envelope curves. For Indian rivers, envel-
oping curves from observed floods have been developed by Kanwar Sain and Karpov, Fig. 8.1 (a).
(iv) Concentration Time Method. The concentration time method of estimating the peak
discharge consists of two steps:
(i) Determination of the concentration time, etc.
(ii) Selection of the period of maximum net rainfall for the concentration time duration.
This method can be used for design storms or in conjunction with intensity-duration-
frequency curves.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 215
FLOODS-ESTIMATION AND CONTROL 215
Log-log paper
100
80
60
40
30
20
10
8
6
4
3
2
1
1 2 3 4 5 6 8 10 20 30 40 60 80100 200 300 5007001000
1
10
100
1000 100 10
M
a
x
i
m
u
m
f
l
o
o
d
d
i
s
c
h
a
r
g
e
(
1
0
0
0
c
u
m
e
c
)
Catchment area (1000 km )
2
R
iv
e
r
s
in
n
o
r
t
h
a
n
d
c
e
n
t
r
a
l
I
n
d
ia
R
iv
e
rs
in
s
o
u
th
In
d
ia
1
Fig. 8.1(a) Enveloping curves of Kanwar Sain and Karpov
Example 8.1 Determine the peak discharge at the concentration point for a basin of 80 hec-
tares having a time of concentration of 30 minutes due to a 5-cm flash storm, if the duration of
the storm is (i) 60 min, (ii) 30 min, and (iii) 15 min. Assume a -index of 2.5 cm/hr for the entire
basin. When the storm duration is 15 minutes, only drainage from 60% of the area of the basin
reaches the concentration point.
Solution
Q = (i ) A, where i = intensity of rainfall (cm/hr)
(i) Q = (5 2.5) 80 = 200 ha-cm = 200 0.028 = 5.6 cumec
(ii) Q = (
5
30
60 2.5) 80 = 600 ha-cm = 600 0.028 = 16.8 cumec
(iii) Q = (
5
15
60 2.5) (0.60 80) = 840 ha-cm = 840 0.028 = 23.52 cumec
It is seen from (i) and (ii) that the peak discharge at the concentration point is maxi-
mum when the duration of storm is equal to the time of concentration, (iii) gives the highest
flood, since only 60% of the area drains, the concentration time becomes less and the intensity
of rainfall is very high during this time.
(v) Rational Method. The rational method is based on the application of the formula
Q = CiA ...(8.9)
where C is a coefficient depending on the runoff qualities of the catchment called the runoff
coefficient (0.2 to 0.8). The intensity of rainfall i is equal to the design intensity or critical
intensity of rainfall i
c
corresponding to the time of concentration t
c
for the catchment for a
given recurrence interval T; the design intensity of rainfall i (= i
c
) can be found from the
intensity-duration-frequency curves, for the catchment corresponding to t
c
and T. If the
intensity-duration-frequency curves, are not available for the catchment and a maximum
precipitation of P cm occurs during a storm period of t
R
hours, then the design intensity i (= i
c
)
can be obtained from the equation
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 216
216 HYDROLOGY
i
c
=
P
t
t
t
R
R
c
+
+
F
H
G
I
K
J
1
1
...(8.10)
when the time of concentration, t
c
is not known, i
c
P/t
R
.
The values of the runoff coefficient C are given in Table 8.1 and serve as a rough guide.
Table 8.1 Value of the runoff coefficient C
Type of terrain Value of C
Flat residential areas 0.4
Moderately steep residential area 0.6
Built up areasimpervious 0.8
Rolling lands and clay-loam soils 0.5
Hilly areas, forests, clay and loamy soils 0.5
Flat cultivated lands and sandy soils 0.2
Example 8.2 For an area of 20 hectares of 20 minutes concentration time, determine the peak
discharge corresponding to a storm of 25-year recurrence interval. Assume a runoff coefficient
of 0.6. From intensity-duration-frequency curves for the area, for T = 25-yr, t = 20 min, i = 12
cm/hr.
Solution For t = t
c
= 20 min, T = 25-yr, i = i
c
= 12 cm/hr
Q = CiA = 0.6 12 20 = 144 ha-cm/hr = 144 0.028 = 4 cumec
Note 1 ha-cm/hr =
1
36
cumec = 0.028 cumec
Example 8.3 Determine the design flood discharge (allowing an increase of one-third) for a
bridge site with the following data:
Catchment area = 2 10
5
ha
Duration of storm = 8 hours
Storm precipitation = 3 cm
Time of concentration = 2 hr
Gauged discharge for a past flood with average maximum daily rainfall of 18 cm was
3400 cumec.
Solution From the past flood,
Runoff coefficient, C =
Actual discharge
Theoretical discharge
=
3400
2 10 10
18
100
1
24 60 60
5 4


= 0.815
Design or critical intensity of rainfall
i = i
c
=
P
t
t
t
R
R
c
+
+
F
H
G
I
K
J
1
1
=
3
8
8 1
2 1
+
+
F
H
G
I
K
J
= 1.125 cm/hr
Q = CiA = 0.815 1.125 (2 10
5
) = 1.83 10
5
ha-cm/hr
or, (1.83 10
5
) 0.028 = 5130 cumec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 217
FLOODS-ESTIMATION AND CONTROL 217
From Inglis formula
Q =
124
10 4
A
A + .
, A is in km
2
and 1 km
2
= 100 ha

124 2000
2000 10 4

+ .
= 5520 cumec
Design flood discharge = 5520 1.33 = 7350 cumec
(vi) The Unit Hydrograph Method. For small and medium size basins (A < 5000 km
2
,
i.e., when a single unit hydrograph could be applied to the entire basin) in developing design
flood hydrographs by applying the unit hydrograph for the basin, the design storm estimates
are made by the following methods.
(i) Selection of major storms
(ii) Maximization of selected storms
(iii) Plotting the depth-area-duration curves and their analysis
(iv) Moisture adjustment
(v) Storm transposition to a critical position
(vi) Envelopment of the transposed adjusted storms
(vii) Use of minimum infiltration indices
In the depth-area-duration analysis of a particular storm, the maximum average depths
of rainfall over various sizes of area during certain periods of storm (hr or days), say cm over
1000 km
2
in 1 day, 2 days or 3 days from the isohyetal maps contructed (see Fig. 2.15). Such
values determined for all the transposable storms provide the basic data to estimate the PMP
over the basin.
Example 8.4 Computation of Maximum Probable Flood of River Tapi at Ukai
Since the catchment was partly surrounded by hills, depth-area-duration or storm transposi-
tion techniques were not considered proper and storm analysis was done on the basis of the
catchment as the unit of study, i.e., by the depth-duration method.
1. Storm analysis. From the 1-day, 2-days and 3-days isohyetal maps for the most se-
vere 3-days storm of 1968 that occurred over the Tapi Basin up to Ukai (Central India) on 4th,
5th and 6th August 1968, the depth-duration curve was drawn and the weighted maximum
rainfall depths for 1, 2 and 3 days are 11.43, 22.38 and 25.96 cm, respectively.
2. Storm maximisation with respect to moisture charge. Since the storm of 1968 had its
centre inside the catchment on all the days of the storm, it was assumed that the highest
efficiency had been already attained during the storm in respect of all other meteorological
parameters except moisture content. The moisture adjustment factor, which is the ratio of
maximum precipitable water at storm location to that available during storm period was derived
with respect to standard level of 500 mb and was of the order of 1.23. The storm of 46 August
1968 was increased by 23% to arrive at maximum probable storm.
3. Minimum infiltration losses. For the storm of 1968, the rainfall of 25.96 cm had resulted
in a surface runoff 11.7 cm with an infiltration loss of 14.26 cm. As the infiltration losses would
be higher in the beginning of rainfall period and gradually decrease as the runoff proceeds, a
varying rate of infiltration was adopted. The rainfall excesses were computed by deducting the
losses from each 6-hour maximised storm values as given below:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 218
218 HYDROLOGY
Rainfall during Infiltration rate Infiltration loss in Rainfall
6-hr interval (cm/hr) 6-hr interval excess
(cm) (cm) (cm)
10.5 0.25 1.5 9.0
6.0 0.25 1.5 4.5
4.4 0.24 1.44 2.96
2.7 0.24 1.44 1.26
1.5 0.23 1.38 0.12
1.0 0.23 1.38
0.8 0.23 1.38
0.6 0.23 1.38
1.3 0.20 1.20 0.10
1.1 0.20 1.20
1.0 0.20 1.20
0.9 0.20 1.20
31.8 17.94
Total loss = 31.80

17.94 = 13.86 cm
4. Maximum probable flood hydrograph. The 6-hour rainfall excesses were rearranged
in a sequence so as to produce the most severe flood peak and then applied to the ordinates of
the 6-hour design unit hydrograph derived from the 1968 flood hydrograph at Kakrapar weir
at Ukai with a lag of 6 hours successively and the ordinates of the surface runoff hydrograph of
the maximum probable flood arrived at. The constant base flow of 2400 cumec was then added
to arrive at the final ordinates of the flood hydrograph of maximum probable flood (MPF). The
peak of this hydrograph is 59800 cumec, Table 8.2, and is shown in Fig. 8.1. The highest peak
attained during 1876-1968 (93 years) was 42500 cumec in August 1968 and the second highest
was 37300 cumec in September 1959. The MPF recommended by CWPC, India for the design
of Ukai dam was almost the same as 59800 cumec while the SPF recommended was around
48200 cumec. The design flood adopted was 49500 cumec.
5. Limitation. Unit hydrograph is generally applicable for catchments of less than 5000
km
2
since according to the theory, storm distribution over the area is assumed to be fairly
even. The catchment of Tapi river up to Ukai dam is nearly 62000 km
2
which is considerably
greater than the limit for unit hydrograph application. In such cases, the correct method would
be to subdivide the whole catchment into a number of sub-basins, and separately carry out
unit hydrograph application for these sub-basins, and thereafter to arrive at the maximum
flood for the catchment by routing the flood through the various river reaches. But this method
naturally requires extensive gauge and discharge data for the individual sub-basins and at the
lowest side, as also intermediate cross section of the river channel for the whole reach in order
to enable routing of the floods derived for the sub-basins. For Tapi, however, such extensive
data was not available and the catchment could not be sub-divided into sub-basins; the whole
catchment up to Ukai dam has been treated as a single unit.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 219
FLOODS-ESTIMATION AND CONTROL 219
T
a
b
l
e

8
.
2

C
o
m
p
u
t
a
t
i
o
n

o
f

m
a
x
i
m
u
m

p
r
o
b
a
b
l
e

f
l
o
o
d

o
f

R
i
v
e
r

T
a
p
i

a
t

U
k
a
i
,

A

=

6
2
0
0
0

k
m
2
.

(
E
x
a
m
p
l
e

8
.
4
)
T
i
m
e
6
-
h
r

U
G
O
R
a
i
n
f
a
l
l

e
x
c
e
s
s
e
s
D
R
O
B
F
O
T
R
O
(
h
r
)
(
c
u
m
e
c
)
0
.
1
2
1
.
2
6
4
.
5
9
.
0
2
.
9
6
s
u
b
-
t
o
t
a
l
(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
0
0
0
0
2
4
0
0
2
4
0
0
6
2
7
9
3
1
0
3
1
0
2
4
0
0
2
7
1
0
1
2
9
3
5
1
0
5
3
5
0
1
0
7
5
2
4
0
0
3
4
7
5
1
8
1
9
4
0
2
2
0
1
1
8
1
2
5
6
0
3
5
3
4
2
4
0
0
5
9
3
4
2
4
2
5
0
0
2
8
3
2
4
4
4
2
0
0
2
5
1
2
0
9
7
3
9
2
4
0
0
1
2
1
3
9
3
0
3
0
0
0
3
4
0
3
1
5
8
7
0
0
8
5
1
0
8
2
5
2
1
6
9
0
2
4
0
0
2
4
0
9
0
3
6
3
3
4
0
3
7
8
3
7
8
1
1
2
4
0
1
7
5
0
0
2
7
6
4
3
5
6
0
0
2
4
0
0
3
8
0
0
0
4
2
3
2
2
0
3
6
4
4
2
0
1
3
5
0
0
2
2
5
2
0
5
7
5
0
4
5
7
7
4
2
4
0
0
4
8
1
7
4
4
8
2
9
4
0
3
3
3
4
0
5
1
5
0
0
0
2
7
0
0
0
7
4
0
0
5
3
0
7
8
2
4
0
0
5
5
4
7
8
5
4
2
6
6
0
3
0
1
3
7
0
1
4
6
0
0
3
0
6
0
0
8
8
7
0
5
7
4
0
1
2
4
0
0
5
9
8
0
1


p
e
a
k
6
0
2
0
5
0
2
3
3
3
3
5
1
3
2
0
0
2
9
0
0
0
9
8
9
0
5
4
7
0
8
2
4
0
0
5
7
1
0
8
6
6
1
2
8
0
1
4
5
2
5
8
1
1
9
6
0
2
6
4
8
0
9
5
3
0
4
9
6
5
3
2
4
0
0
5
2
0
5
3
7
2
9
6
3
1
0
9
1
6
1
9
2
0
0
2
3
9
8
0
8
7
0
0
4
3
1
1
3
2
4
0
0
4
5
5
1
3
7
8
7
7
5
8
8
1
2
1
5
7
3
0
1
8
5
0
0
7
8
7
0
3
3
0
8
4
2
4
0
0
3
5
4
8
4
8
4
6
5
1
7
4
9
8
4
3
3
0
1
1
5
0
0
6
0
7
0
2
2
6
2
3
2
4
0
0
2
5
0
2
3
(
C
o
n
t
d
.
.
.
)
p
.

2
2
0
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 220
220 HYDROLOGY
9
0
5
4
0
6
1
8
2
3
4
9
0
8
1
7
0
3
7
9
0
1
6
1
3
3
2
4
0
0
1
8
5
3
3
9
6
4
1
8
4
7
6
8
2
9
3
0
6
9
8
0
2
8
5
0
1
3
2
9
3
2
4
0
0
1
5
6
9
3
1
0
2
3
2
9
3
7
5
3
2
4
3
0
5
8
6
0
2
2
9
0
1
0
9
9
9
2
4
0
0
1
3
3
9
9
1
0
8
2
6
7
3
0
4
1
1
8
8
0
4
8
6
0
1
9
3
0
9
0
0
7
2
4
0
0
1
1
4
0
7
1
1
4
2
1
2
2
4
3
4
1
4
8
0
3
7
7
0
1
6
0
0
7
1
2
0
2
4
0
0
9
5
2
0
1
2
0
1
5
6
1
8
2
7
1
2
0
0
2
9
6
0
1
2
4
0
5
6
0
1
2
4
0
0
8
0
0
1
1
2
6
1
1
1
1
3
2
0
9
5
0
2
4
0
0
9
7
4
4
4
6
8
2
4
0
0
6
8
6
8
1
3
2
8
6
1
0
1
4
6
9
8
1
9
1
0
7
9
0
3
5
0
8
2
4
0
0
5
9
0
8
1
3
8
5
8
7
1
1
4
9
7
1
4
0
4
6
2
7
2
6
0
4
2
4
0
0
5
0
0
4
1
4
4
3
1
4
7
3
8
7
1
0
0
0
4
6
2
1
8
9
1
2
4
0
0
4
2
9
1
1
5
0
0
0
4
2
6
1
7
7
4
3
2
9
1
3
6
8
2
4
0
0
3
7
6
8
1
5
6
0
1
4
0
5
2
2
2
5
4
9
1
6
2
4
0
0
3
3
1
6
1
6
2
0
2
7
9
1
7
2
4
5
1
2
4
0
0
2
8
5
1
1
6
8
0
9
2
9
2
2
4
0
0
2
4
9
2
1
7
4
0
0
2
4
0
0
2
4
0
3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 221
FLOODS-ESTIMATION AND CONTROL 221
65
60
55
50
45
40
35
30
65
25
20
15
10
5
0
.12
1.26
4.5
9.0 cm
2.96
P -max probable
(Rearranged)
net
30 hr
6 6 6 6 6
hr
R
a
i
n
f
a
l
l
i
n
t
e
n
s
i
t
y
i
,
(
c
m
/
h
r
)
A = 62000 km
2
Design flood = 49500 cumec (D.F.)
59800 cumec = MPF
48200 = SPF
CWPC
cumec
42500 = 1968 Flood
cumec (maximum)
Flood hydrograph
36
32
28
24
20
16
12
8
4
D
i
s
c
h
a
r
g
e
Q
(
6
-
h
r
U
G
)
,
(
1
0
0
c
u
m
e
c
)
F
l
o
o
d
d
i
s
c
h
a
r
g
e
Q
(
1
0
0
0
c
u
m
e
c
)
0
0 12 24 36 48 60 72 96 108 120 132 144 156 168 180
174 150
Constant base flow = 2400 cumec
Time t (hr)
6-hr design UG
(Q- scale exaggerated)
MPF
D.F.
1968
Fig. 8.1 MPF of river Tapi at Ukai (Example 8.4)
8.4 FLOOD FREQUENCY STUDIES
When stream flow peaks are arranged in the descending order of magnitude they constitute a
statistical array whose distribution can be expressed in terms of frequency of occurrence. There
are two methods of compiling flood peak datathe annual floods and the partial duration
series. In the annual floods, only the highest flood in each year is used thus ignoring the next
highest in any year, which sometimes may exceed many of the annual maximum. In the par-
tial duration series, all floods above a selected minimum are taken for analysis, regardless of
the time-interval, so that in some years there may be a number of floods above the basic stage,
while in some other years there may not any such flood at all. The disadvantage of the partial
duration series is that the data do not furnish a proper frequency (true distribution) series and
so a reasonable statistical analysis cannot be made. But all the larger floods are used in this
analysis, which is an advantage while in annual flood series some big floods are omitted be-
cause they were not the highest floods in any year considered. Usually the basic stage is as-
sumed sufficiently low so that as many peaks (4 or 5) as possible each year are above this
stage. The two series give very nearly the same recurrence interval for the larger floods, but
the partial series indicates higher floods for shorter recurrence intervals. For information about
floods of fairly frequent occurrence, as is required during the construction period of a large
dam (say, 4-5 years), the partial series are the best, while for the spillway design flood the
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 222
222 HYDROLOGY
annual series are preferable, since the flood should not be exceeded in the dams life time, say
100 years.
Annual Flood Series The return period or recurrence interval (T) is the average number
of years during which a flood of given magnitude will be equalled or exceeded once and is
computed by one of the following methods.
California method (1923):
T =
n
m
...(8.11)
Allen Hazen method (1930):
T =
n
m
n
m
=

1
2
2
2 1
...(8.11 a)
Weilbul method (1939):
T =
n
m
+ 1
...(8.11 b)
where n = number of events, i.e., years of record
m = order or rank of the event (flood item) when the flood magnitudes (items) are ar-
ranged in the descending order (m = 1 for the highest flood, m = n for the lowest
flood)
T = recurrence interval (T = n-yr for the highest flood, T = 1 yr for the lowest flood, by
California method)
The probability of occurrence of a flood (having a recurrence interval T-yr) in any year,
i.e., the probability of exceedance, is
P =
1
T
...(8.12)
or the percent chance of its occurrence in any one year, i.e., frequency (F) is
F =
1
T
100 ...(8.12 a)
and the probability that it will not occur in a given year, i.e., the probability of non-exceedance
(P), is
P = 1 P ...(8.12 b)
One interesting example of the application of statistics to a hydrologic problem (i.e.,
stochastic hydrology), is Gumbels theory of extreme values. The probability of an event of
magnitude x not being equalled or exceeded (the probability of non-occurrence, P), based on
the argument that the distribution of floods is unlimited (i.e., for large values of n, say n > 50),
P = e
e
y


...(8.13)
and the probability of the event x being equalled or exceeded (i.e., probability of occurrence, P) is
P = 1 P = 1 e
e
y


...(8.13 a)
where e = base of natural logarithms
y = a reduced variate given by
y =
1
078 .
(x x + 0.45 ), for n > 50 ...(8.14)
x = flood magnitude with the probability of occurrence, P
x = arithmetic mean of all the floods in the series
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 223
FLOODS-ESTIMATION AND CONTROL 223
x =
x
n
, x
2
=
x
n
2
= standard deviation of the flood series
=
( ) x x
n

2
1
=
n
n
x x


1
2 2
[ ( ) ] ...(8.15)
=
x x n
n
2 2
1

( ) /
...(8.15 a)
n = number of items in the series, i.e., the number of years of record.
and the recurrence interval of the event of magnitude x (See Chapter-15)
T =
1 1
1
P
e
e
y
=



...(8.16)
If the event x, of recurrence interval T-yr, is x
T
, then from Eq. (8.14)
x
T
= x + (0.78 y 0.45), for n > 50 ...(8.17)
or in terms of flood discharge items.
Q
T
= Q + (0.78 log
e
T

0.45), for n > 50 ...(8.17 a)
Q = Q
T
, when 0.78y = 0.45, or y = 0.577 which corresponds to T = 2.33 yr. The final plot of flood
items (x) versus recurrence interval (T) can be made on probability or semi-logarithmic paper.
In the Gumbel-Powell probability paper, the plotting paper is constructed by laying out on a
linear scale of y the corresponding values of T given by Eq. (8.16) (after Powell, R.W., 1943)
and is given in Table 8.3. It is sufficient to calculate the recurrence interval of two flood flows,
say mean flood x (or Q with T = 2.33 yr) and x
150
or Q
150
obtained from Eq. (8.17 a) putting
T = 150, and to draw a straight line through these points. A third point serves as a check,
Fig. 8.2. This straight line can then be extrapolated to read the flood magnitude against any
desired return period (T). The Gumbel distribution does not provide a satisfactory fit for par-
tial duration floods or rainfall data.
Actual observations of flood data reveal that there are a greater number of floods below
the mean than those above it and variations above the mean are greater than those below the
mean. Therefore, a curve which fits the maximum 24-hour annual flood data on a log-log paper
will not be a symmetrical curve, but a skew curve which is unsymmetrical, i.e., the points do
not lie on a straight line but the line bends off. The general slope of this curve is given by the
coefficient of variation C
v
, and the departure from the straight line is given by the coefficient of
skew C
s
, While plotting the skew probability curves, three parameters have to be calculated
from observed flood data as
(i) Coefficient of variation, C
v
=

x
...(8.18)
(ii) Coefficient of skew, C
s
=
( )
( )
x x
n

3
3
1
(Foster) ...(8.19)
(iii) Coefficient of flood, C
f
=
x
A
0.8
/2.14
...(8.20)
where A = area of the catchment in km
2
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 224
224 HYDROLOGY
Table 8.3 Gumbels probability data
Reduced variate Recurrence interval Probability of exceedance
(y) (T) (P)
1.53 1.01 0.99 ( 1.0)
0.475 1.25 0.80
0 1.58 0.63
0.37 2.00 0.50
0.58 2.33 0.43
1.50 5 0.20
2.25 10 0.10
2.97 20 0.05
3.90 50 0.02
4.60 100 0.01
5.30 200 0.005
5.70 300 0.0033
6.00 403 0.0025
6.24 500 0.002
6.92 1000 0.001
7.62 2000 0.0005
8.54 5000 0.0002
9.92 10000 0.0001
0.25 0.67
0.5
1.33 2 4 5
6.25
10 12.5 20 43 50 63 80 99
Q
150
Observed
93-yr flood
B
Q
150
Q
25
C (check)
F
l
o
o
d
f
r
e
q
u
e
n
c
y
l
i
n
e
G
u
m
b
e
l
A
Q mean
(T = 2.33)
Q (or x)

Q
25
% Chance or probability of flood > Q, in any one year
Frequency F = 100 %
1
T
50
40
30
20
10
0
1.01 1.251.58 2 2.33 5 810 162025 50 75100150200 400
.475
.656
1.17
1 .53
y
T
.367
0.577
3.43
1.07
Reduced Variate y (to linear scale)
1.5
2.02
2 2.25
2.74
2.97
33.2
3.902
4
4.32 4.6 5 5.296 6
y
T
(Recurrence interval T-yr:) T =
1
1e
e
y
A
n
n
u
a
l
p
e
a
k
f
l
o
o
d
Q
,
c
u
m
e
c
(
1
0
0
0
)

1
1
Fig. 8.2 Gumbel-Powell probability paper
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 225
FLOODS-ESTIMATION AND CONTROL 225
When the flood items are tabulated in terms of mean flood, C
v
= . If the annual flood is
x and the mean flood is x , then the annual flood in terms of mean flood is x/ x . The coefficient
of variation for annual precipitation data is equal to the standard deviation of the indices of
wetness.
While a small value of C
v
indicates that all the floods are nearly of the same magnitude,
a large C
v
indicates a range in the magnitude of floods. In other word C
v
represents the slope
of the probability curve, and the curve is horizontal if C
v
= 0. The actual length of records
available has a very little effect on the value of C
v
, i.e., C
v
for a 20-yr record varies very little
from that for a 100-yr record.
The coefficient of skew, C
s
is seriously affected by the length of record and will be too
small for a short period; C
s
is then modified to allow for the period of record (n) by multiplying
by a factor (1 + k/n) where the constant K = 6 to 8.5. If even this adjusted C
s
does not give a
curve to fit actual observed data, an arbitrary value of C
s
will have to be assumed to fit the
curve for the given annual flood data. From this theoretical curve can then be read off the
probability or the percentage of time, of a flood of any given magnitude occurring, usually,
C
s
2 C
v
...(8.21)
The coefficient of flood indicates the general magnitude of the floods in the particular
stream; hence, it fixes the height of the curve above the base. Using C
f
, the mean flood of a
stream, for which no flood data are available, can be got, as
Mean flood = C
f

A
0.8
2 14 .
...(8.22)
The exponent 0.8 is the slope of the line obtained by plotting the mean annual flood
against water-shed area for a number of streams. Almost all observed data till to-date confirm
this value originally obtained by Fuller.
8.5 ENCOUNTER PROBABILITY
Even if a flood of a long recurrence interval is chosen, there is always a possibility that the
flood can be exceeded more then once during the interval. The probability of r events occur-
ring in N possible events is given by
P
(N, r)
=
N
r N r
!
! ( ) !
P
r
(1 P)
Nr
...(8.23)
where P = probability of a single event.
If r = 0, the flood will not be exceeded during the N years, the useful life of the struc-
ture. Then Eq. (8.23) becomes
Probability of non-exceedance, P
(N, 0)
= (1 P)
N
...(8.23 a)
So, the probability that the design flood (T-year flood, annual probability of occurrence
P = 1/T) will be exceeded one or more times during N year (useful life of the structure) is given
by
Probability of exceedance, P
Ex
= 1 (1 P)
N
...(8.23 b)
and the percentage risk = P
Ex
100 (8.23 c)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 226
226 HYDROLOGY
Thus, the probability of a 100-year flood will not be exceeded in the next 50 years is
P
(N, 0)
= 1
1
100
50

F
H
G
I
K
J = 0.6 or 60%
or 6 chances in 10; and the probability that the 100-year flood will be exceeded once or more
during the next 50 years is
P
Ex
= 1 0.6 = 0.4 or 40%
or 4 chances in 10
As another example, to determine the recurrence interval of a design flood having a
63% risk of being exceeded during a 100-year period
P
Ex
= 1

(1 P)
N
0.63 = 1 (1 P)
100
from which P = 0.01. Hence, T =
1 1
0 01 P
=
.
= 100 years.
The percentage probabilities of floods (or rainfall) of different recurrence intervals (T)
to occur in particular periods (N) are given in Table 8.4.
Table 8.4 Probability (%) of T-yr flood to occur in a period of N-years
Period (N-years) Average recurrence interval of flood (T-yr)
5 10 50 100 200
1 20 10 2 1 0.5
5 67 41 10 5 2
10 89 65 18 10 5
25 99.6 93 40 22 12
50 99.5 64 40 22
100 87 63 39
200 98 87 63
500 99.3 92
Partial duration curve method Partial duration curves are plotted showing the flood
discharges against their probable frequency of occurrence in 100 years and not against per-
centage of time as in the annual flood series.
Probable frequency =
m
y
100 ...(8.24)
where m = order number or rank of the particular flood in the series of items selected and
arranged in the descending order of magnitude
y = total length of record in years
The number of flood items selected need not be greater than the number of years in
record to simplify the procedure. Gumbel paper should not be used for partial series, which
usually plot better on semi-log paper.
Frequency method may be used for drainage basins of any size. The reliability of the
frequency estimates depends on the length of the observed record rather than the method of
probability analysis. Thus, if a 50-year record is available, a 10-yr flood may be predicted with
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 227
FLOODS-ESTIMATION AND CONTROL 227
assurance, while the 50-yr or 100-yr floods could be estimated only very approximately. The
procedure in frequency analysis is (i) compilation of flood peaks in the descending order of
magnitude, (ii) computation of recurrence intervals by any one of the stochastic methods, and
(iii) plotting the flood peaks versus recurrence interval from which the flood (or rainfall) of a
required recurrence interval can be read or extrapolated, or the recurrence interval for a given
flood magnitude (or rainfall) can be read or extrapolated.
The limitations of frquency methods are that the greatest floods are caused by an unu-
sual meteorological combination resulting in unexpected peculiar storms. Hence, the probabil-
ity studies alone are inadequate for predicting floods of very great magnitudes.
Example 8.5 Flood frequency studies are made for the 30-year flood data (from 1939-1968) of
lower Tapi river at Ukai as shown in Table 8.5 both by Weibull and Gumbels methods.
(a) Gumbels method
n = 30, mean flood x =
426.27
30
= 14.21 or 14210 cumec
Standard deviation of the annual flood series,
=
( ) x x
n

2
1
=
2724 26
30 1
.

= 9.7
Recurrence interval of mean flood of 14.21 thousand cumec is 2.33 yr. Flood magnitude
Q
100
having a recurrence interval of 100-yr is given by
Q
T
= Q + (0.78 log
e
T 0.45)
Q
100
= 14.21 + 9.7(0.78 log
e
100 0.45) = 44.65 or 44650 cumec
plot the reduced variate y to a linear scale on the x-axis and the flood magnitudes on the y-
axis to natural scale (Fig. 8.3). Plot the first point to A as x = Q = 14.21 thousand cumec
against y = 0.577 corresponding to T = 2.33 yr. Plot the second point B as x
100
= Q
100
= 44.65
thousand cumec against y = 4.6 corresponding to T = 100 yr. Join AB and produce which will
yield a straight plot. Take a third point C as, say Q
50
given by
Q
50
= 14.21 + 9.7 (0.78 3.9 0.45)
since for T = 50 yr, y = 3.9
Q
50
= 39.31 thousand cumec
Now plot C as 39.310 cumec against y = 3.9, which lies on the straight line plot AB.
Similarly, several points can be located on the straight line plot but a third point C is enough
to check the straight line plot.
Below the x-axis, write the values of T corresponding to the reduced variate y. On the
horizontal axis on the top of the graph, the percentage probability P(= 100/T) is plotted vartically
above the corresponding T-values. Now from the graph, the statistical information required
can be read or extrapolated as
(i) 150-yr flood (T = 150 yr), Q = 47500 cumec
(ii) 20-yr flood (T = 20 yr, y = 2.97, P = 5%), Q = 32000 cumec
(iii) 10-yr flood (T = 10 yr, y = 2.25, P = 10%), Q = 26750 cumec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-1.PM5 228
228 HYDROLOGY
(iv) For a peak flood (Q) of 40,000 cumec, y = 4.0, T = 55 yr
(v) For the SPF of 48200 cumec, extrapolate to get y = 5.05, T = 156 yr.
Hence, the SPF recommended by CWPC seems to be a feasible one.
(vi) Frequency of 1968 flood of 42500 cumec, T = 74 yr and P = 1.35%; but actually it
occurred in 93 years (1876-1968).
Gumbel - Powell probability paper 30 - yr (1939 - 68) flood data of R. Tapi at Ukai
Frequency F = 100 = % chance P = probability of
Q being equalled or exceeded in any one year

1
T
SPF of 48.2 thousand cumec, T = 156 yr
Flood of 50.0 thousand cumec, T = 200 yr
100 - yr flood = 44.65 thousand cumec
55 - yr flood = 40 tcmc
150 - yr flood = 47.5 thousand cumec
1968 flood of 42.5 tcmc has Y = 4.3, T = 74 - yr, F = 1.35%
X = X + (0.78 log T 0.45)
for n > 50
T e
s
F
r
e
q
u
e
n
c
y
o
r
p
r
o
b
a
b
i
l
i
t
y
c
u
r
v
e
X
=
x
+
(
0
.
7
8
y

0
.
4
5
)
T
s
x = 14.21 = mean flood
12.5 = median flood
50
45
40
35
30
25
20
15
10
5
0.656 1.53
F
l
o
o
d
d
i
s
c
h
a
r
g
e
Q
(
1
0
0
0
c
u
m
e
c
)
26.75
24.2
32
39.31
40
42.5
44.65
99
47.5
48.2
80 63.2 50 42.9 20
Frequency F %
10 5 2 1.35 1 0.5 45
50
40
35
30
25
20
15
10
5
Y
T
B
C
P = %
100
T
Hence
SPF of 48.2 tcmc
is ok.
Q
i
n
1
0
0
0
m
/
s
3
5.296
0
156
5.05
5.0 4.6 4.3 4 3.9
74 55
200 150 100 50
3.16 3 2.74 2.25 2 1.5
2.01 2.97
24 20 16 10 6.58 5
1.07
1
3.43 2.33 2
0.577 0.367 0
1.59 1.25
0.475
1.17
1.0 1.5
1.01
Y
T
Reduced variate y (to linear scale)
Recurrence interval T - yr: T =
1
1 e
e
y
Observed
93 yr flood
A
Fig. 8.3 Frequency curve of annual floods-Gumbels method (Example 8.5)
Coefficient of variation, C
v
=

x
=
97
14 21
.
.
= 0.68
Coefficient of skew, C
s
=
( )
( )
x x
n

3
3
1
=
34319
30 1 9 7
3
( )( . )
= 1.3
Note that C
s
2C
v
C
s
adjusted to allow for the period of record (Foster, 1924)
C
s
= C
s

1+
F
H
G
I
K
J
k
n
= 1.3
1
6
30
+
F
H
G
I
K
J = 1.56
For Fosters Type I curve k = 6, and for Type III curve k = 8.5
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 229
FLOODSESTIMATION AND CONTROL 229
Coefficient of flood, C
f
=
x
A
0.8 0.8
2 14
14210
62000 2 14 / . ( ) / .
=
= 4.46
(b) Fosters Method From the value of C
s
, the values of the factor K giving the variations
of the peak flood from the mean flood at various percentages of time (i.e.,, probability P%) can
be obtained by referring to the Tables 8.6 and 8.7 prepared by Foster. From this, the flood
frequency curve can be drawn; and the probability and recurrence interval (T = 1/P 100) of a
desired flood magnitude can be read off from the curve.
In Example 8.5, for Q = 14.21 tcm, = 9.7 tcm, C
s
= 1.56, from Table 8.6, the flood
frequencies can be determined as follows (tcm = thousand cumec):
Frequency Recurrence Skew curve Variation Flood peak
P (%) interval factor K from the Q
T
= Q + K
(T-yr) (from Table 8.6 mean flood (tcm)
for C
s
= 1.6) K (tcm)
0.01 10000 5.67 52.1 66.31
0.1 1000 4.75 43.7 57.91
1 100 3.40 31.25 45.46
5 20 2.07 19.05 33.26
20 5 0.69 6.35 20.56
50 2 0.32 2.94 11.27
100 1 0.96 9.32 4.89
The frequency curve is shown in Figs. 8.4 and 15.1. While the highest flood observed in
93 years (1876-1968) is 42.5 tcm, the 100-year flood by Fosters Type I curve is predicted as
45.46 tcm.
Table 8.6 Skew Curve Factors (K values) for Fosters Type I curve
C
s
Frequency P (%)
99 95 80 50 20 5 1 0.1 0.01 0.001 0.0001
0 2.08 1.64 0.92 0 0.92 1.64 2.08 2.39 2.53 2.59 2.62
0.2 1.91 1.56 0.93 0.05 0.89 1.72 2.25 2.66 2.83 2.94 3.00
0.4 1.75 1.47 0.93 0.09 0.87 1.79 2.42 2.95 3.18 3.35 3.44
0.6 1.59 1.38 0.92 0.13 0.85 1.85 2.58 3.24 3.59 3.80 3.92
0.8 1.44 1.30 0.91 0.17 0.83 1.90 2.75 3.55 4.00 4.27 4.43
1.0 1.30 1.21 0.89 0.21 0.80 1.95 2.92 3.85 4.42 4.75 4.95
1.2 1.17 1.12 0.86 0.25 0.77 1.99 3.09 4.15 4.83 5.25 5.50
1.4 1.06 1.03 0.83 0.29 0.73 2.03 3.25 4.45 5.25 5.75 6.05
1.6 0.96 0.95 0.80 0.32 0.69 2.07 3.40 4.75 5.67 6.25 6.65
1.8 0.87 0.87 0.76 0.35 0.64 2.10 3.54 5.05 6.08 6.75 7.20
2.0 0.80 0.79 0.71 0.37 0.58 2.13 3.67 5.35 6.50 7.25 7.80
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 230
230 HYDROLOGY
Table 8.7 Skew Curve Factors (K values) for Fosters Type-III curve
C
s
Frequency P (%)
99 95 80 50 20 5 1 0.1 0.01 0.001 0.0001
0 2.33 1.64 0.84 0 0.84 1.64 2.33 3.09 3.73 4.27 4.76
0.2 2.18 1.58 0.85 0.03 0.83 1.69 2.48 3.08 4.16 4.84 5.48
0.4 2.03 1.51 0.85 0.06 0.82 1.74 2.62 3.67 4.60 5.42 6.24
0.6 1.88 1.45 0.86 0.09 0.80 1.79 2.77 3.96 5.04 6.01 7.02
0.8 1.74 1.38 0.86 0.13 0.78 1.83 2.90 4.25 5.48 6.61 7.82
1.0 1.59 1.31 0.86 0.16 0.76 1.87 3.03 4.54 5.92 7.22 8.63
1.2 1.45 1.25 0.85 0.19 0.74 1.90 3.15 4.82 6.37 7.85 9.45
1.4 1.32 1.18 0.84 0.22 0.71 1.93 3.28 5.11 6.82 8.50 10.28
1.6 1.19 1.11 0.82 0.25 0.68 1.96 3.40 5.39 7.28 9.17 11.12
1.8 1.08 1.03 0.80 0.28 0.64 1.98 3.50 5.66 7.75 9.84 11.96
2.0 0.99 0.95 0.78 0.31 0.61 2.00 3.60 5.91 8.21 10.51 12.81
2.2 0.90 0.89 0.75 0.33 0.58 2.01 3.70 6.20
2.4 0.83 0.82 0.71 0.35 0.54 2.01 3.78 6.47
2.6 0.77 0.76 0.68 0.37 0.51 2.01 3.87 6.73
2.8 0.71 0.71 0.65 0.38 0.47 2.02 3.95 6.99
3.0 0.67 0.66 0.62 0.40 0.42 2.02 4.02 7.25
In the given example, the 1945 flood of 24200 cumec was exceeded in 1959 (when the
flood was 37300 cumec), i.e., in 14 years. From the graph for Q = 24200 cumec, T = 6.5 yr (7.75-
yr-Weibull); P = 100/6.5 = 15%. The probability that this flood will not occur in the next 14
years is
P
(N, 0)
= (1 0.15)
14
= 0.10 or 10%
and the probability of its occurrence in the next 14 years is
P
Ex
= 1 0.1 = 0.90 or 90%
but actually it is exceeded after 14 years.
(c) Weibulls Method The Weibulls distribution will not give a straight line plot on the
Gumbel-Powel probability paper and hence can better be plotted on a log-log paper. Both the
Gumbells and Weibulls curves are plotted on log-log paper in Fig. 8.4 for comparison. It can
be seen that for smaller floods (say, m 5) both the methods give the same plotting positions ;
but for the larger floods (m < 5), the Weibulls method gives lower recurrence interval, i.e.,
largest floods of increased frequency. For example from the Weibulls frequency curve in Fig. 8.4,
for the SPF of 48.2 thousand cumec, T = 48 yr, while by the Gumbels method T = 160 yr for the
same SPF); for T = 100 yr, Q = 60 thousand cumec.
(d) Fullers formula
Q = CA
0.8
(1 + 0.8 log T) (1 + 2.76A
0.3
)
Q
100
= 2.27 (62000)
0.8
(1 + 0.8 log 100) [1 + 2.76 (62000)
0.3
]
= 40700 cumec (100-yr flood)
against Gumbels 44650 cumec.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 231
FLOODSESTIMATION AND CONTROL 231
Fig. 8.4
30-yr (1939-68)
flood data of
R.Tapi at Ukai
Foster s
type
curve

I
Log-log paper
Gumbel
Foster I
Weibull
Frequency
curves
70 tcmc
60
47 48.2
44
Flood
150-yr
100-yr
48.2 tcm
Weibull
70 tcm
60 tcm
Gumbel
47 tcm
44 tcm
Foster
50 tcm
46 tcm
48-yr
(Frequent
high floods)
T =
n + 1
m
T =
1
1e
e
y
160-yr 146-yr
Q = Q + K
K = (c ,T)
T Q
s
s
f
9
3
-yr
o
b
sd
.flo
o
d
+
48
60
100
80
60
40
30
20
15
10
8
6
4
3
2
1.5
1
1 1.5 2 3 4 6 8 10 15 20 30 40 60 80100 200 400
300 150
Recurrence interval (T-yr)
A
n
n
u
a
l
p
e
a
k
f
l
o
o
d
s
Q
(
1
0
0
0
c
u
m
e
c
)
Q
i
n
1
0
0
0
m
/
s
T
3
1
10
100
0.25 0.5 1 10 25 50 100
Frequency F = % = P or % chance of > Q,
in any one year
100
T
Plotting position
Weibull, 1939
Foster, 1924
Gumbell, 1958
Foster 1
Fig. 8.4 Log-log plot of flood frequency (Example 8.5)
(e) Creagers formula
Q = C(0.386 A
A
)
( )
.
0.894 0.386
0 048
= 140 ( . )
( )
.
0 386 62000
0.894 0.386 62000
0 048



= 36000 cumec, which was well exceeded in the year 1968 when the peak
flood was 42500, cumec.
Hence, the Gumbels method gives the most probable maximum flood in the life period
of a structure to be designed and can be adopted in the safe design of hydraulic structures.
(f) World enveloping flood formula (J.M. Baird and J.F. Meillnraith)
Q =
3010
277
0.78
A
A ( ) +
=
3010 62000
277 62000
0.78

+ ( )
= 33500 cumec
which was well exceeded in the year 1968.
(g) Rational formula
Q = CiA
i = design intensity of rainfall (= i
c
)
= 31.8 cm in 3 days during Aug. 4-6, 1968
(See the Introduction part of Chapter 1)
C = runoff coefficient = 0.43, from the 3-day storm of Aug. 1968
A = 62000 km
2
= 62 10
5
ha
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 232
232 HYDROLOGY
Since 1 ha-cm/hr = 1/36 cumec
Q =
1
36

0.43
31.8 cm
72 hr
62 10 ha
5

F
H
G
I
K
J = 32700 cumec
which has been exceeded in the year 1968. However, the peak flood obtained by the rational
formula depends upon the accuracy of the coefficient of runoff assumed.
Example 8.6 Twenty largest one-day floods (without respect to time) are selected in a period of
20 years arranged in the descending order of magnitude (cumec). Draw the partial duration
curve:
501, 467, 371, 351, 351, 345, 334, 311, 283, 273,
266, 264, 221, 214, 194, 193, 182, 175, 173, 163.
Solution The computations are shown in Table 8.8.
Table 8.8 Computation for partial duration curve
Sl. Flood flow Probable frequency in
no. (cumec) 100 years
1 501 5*
2 467 10
3 371 15
4 351 20
5 351 25
6 345 30
7 334 35
8 311 40
9 283 45
10 273 50
11 266 55
12 264 60
13 221 65
14 214 70
15 194 75
16 193 80
17 182 85
18 175 90
19 173 95
20 163 100
*Probable frequency =
m
y
= 100
1
20
100 = 5
The partial duration curves are plotted on both log-log paper and semi-log paper as
shown in Fig. 8.5 (a) and (b) respectively; the 100-yr flood is extrapolated as 640 and 810
cumec from the curves (a) and (b), respectively.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 233
FLOODSESTIMATION AND CONTROL 233
100-yr flood = 640 cumec
Partial duration
curve
a. Log-log paper
Plotting position
= 100
m
y
1000
800
600
400
300
200
150
100
80
60
40
30
20
10
1 1.5 2 3 4 5 6 8 10 15 20 30 40 60 80100
10
100
1000
100 10 1
F
l
o
o
d
m
a
g
n
i
t
u
d
e
,
Q
(
c
u
m
e
c
)
Partial duration
curve
Plotting position
= 100
m
y
810 cumec = 100 yr
flood
b. Semi-log paper
900
800
700
600
500
400
300
200
100
0
F
l
o
o
d
m
a
g
n
i
t
u
d
e
Q
(
c
u
m
e
c
)
0 10 100
100 80 60 40 30 20 15 10 8 6 5 4 3 2 1.5 1
Frequency in 100 years
Fig. 8.5 Plots of partial duration curve (Example 8.6)
Events having a return period of less than 10 years (P < 0.1) based on annual series will
occur more frequently than indicated because the second or third events in some years may be
greater than the annual events in other years and have been omitted from consideration. If
events that occur frequently (P < 0.1) are important, a partial duration series should be used.
The partial duration series includes all events above a base that has been selected to include at
least one event each year.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 234
234 HYDROLOGY
The partial duration series recurrence interval T
PDS
is related to the annual series
recurrence interval T as
T
PDS
=
1
1 ln ln ( ) T T
Langbein (1949) derived the theoretical relationship between T
PDS
and T as given below.
Though the relationship varies from region to region, it is significant only for recurrence up to
5 years and after that, a difference of 0.5.
T
PDS
T
0.5 1.16
1.0 1.58
1.45 2.00
2.0 2.54
5.0 5.52
10.0 10.5
20.0 20.5
50.0 50.5
100.0 100.5
In partial duration series, since several occurrences in one year may be selected, the
notion of annual occurrence (P
a
) is introduced as
P
a
= m/y
where m = number of occurrences in y years and the probability P in per cent of time is given
by
P = (1 e
P
a

) 100
and the average recurrence interval T = 1/P
a
, and not 1/P
In Example 8.6, a flood of 273 cumec has been exceeded 10 times during a period of 20
years. Then its
annual occurrence P
a
= m/y = 10/20 = 0.5
average recurrence interval T = 1/P
a
= 1/0.5 = 2 yr
annual probability P = (1 e
P
a

) 100 = (1 e
0.5
) 100 = 39.3%.
Example 8.6 (a) The highest annual floods for a river for 60 years were statistically analysed.
The sixth largest flood was 30,000 cumec (30 tcm).
Determine:
(i) The period in which the flood of 30 tcm may reoccur once
(ii) The percentage chance that this flood may occur in any one year
(iii) The percentage chance that this flood may not occur in the next 20 years
(iv) The percentage chance that this flood may occur once or more in the next 20 years
(v) The percentage chance that a 50-yr flood may occur (a) once in 50 years, (b) one or
more times in 50 years
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 235
FLOODSESTIMATION AND CONTROL 235
Solution (i) Weibull; T =
n
m
+ 1
=
60 1
6
+
= 10.1, say 10 yr
(ii) Percentage chance, i.e., P =
1
T
100 =
1
10 1 .
100 = 9.9 say 10%
(iii) Encounter probability,
P
(N, 0)
= (1 P)
N
= 1
1
10 1
20

F
H
G
I
K
J
.
= 0.124 or 12.4%
(iv) P
Ex
= 1 (1 P)
N
= 1 P
(N, 0)
= 1 0.124 = 0.876 or 87.6%
(v) (a) P =
1
T
100 =
1
50
100 = 2%
(b) P
(N, 0)
= 1
1
50
50

F
H
G
I
K
J = 0.3631
P
Ex
= 1 P
(N, 0)
= 1 0.3631 = 0.6369, say 64%
Example 8.6 (b) Determine the percentage chance that a 25-yr storm may occur
(a) In the next 10 years (b) In the next year itself
(c) May not occur in another 15 years
Solution (a) T = 25, P
Ex
= 1 (1 P)
N
, P =
1
T
= 1 1
1
25
10

F
H
G
I
K
J = 0.335 or 33.5%
(b) P
Ex
= 1 1
1
25
1

F
H
G
I
K
J = 0.04 or 4%, i.e., 1 in 25 chance
(c) P
(N, 0)
= (1 P)
N

= 1
1
25
15

F
H
G
I
K
J = 0.542 or 54.2%
Example 8.6 (c) Determine the return period (recurrence interval T) of a flood, which has a
10% risk of being flooded (a) in the next 100 years, (b) in the next 50 years.
Solution P
Ex
= 1 (1 P)
N
, for risk of being exceeded
i.e., P
Ex
= 10% = 0.1
(a) 0.1 = 1 (1 P)
100
, (1 P)
100
= 1 0.1 = 0.9
1 P = 0.9
0.01
= 0.99895, P = 0.00105 = 1.05 10
3
T =
1
P
=
1
105 10
3
.

= 950 yr, say 1000-yr flood
(b) 0.1 = 1 (1 P)
50
, (1 P)
50
= 1 0.1 = 0.9
1 P = 0.9
0.02
= 0.9979
P = 0.0021 = 2.1 10
3
T =
1
P
=
1
2 1 10
3
.

= 476 Yr, say 500-yr flood.
Note. If a structure has a life period of 50 years and if we can accept a 10% risk of its being
flooded during its life, then we have to design the structure for a return period of T-Yr as follows:
P
Ex
= 1 (1 P)
50
; for 10% risk, P
Ex
= 0.1
0.1 = 1 (1 P)
50
, (1 P)
50
= 1 0.1 = 0.9
(1 P) = (0.9)
0.02
= 0.9979
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 236
236 HYDROLOGY
P = 0.0021 = 2.1 10
3
, T =
1 1
10
3
P
=


2.1
= 476 yr
i.e., we have to design the structure for a 476-yr flood and not for a 50-yr flood; if it is designed for a 50
yr flood, the risk of failure
P
Ex
= 1 (1 P)
50
= 1 1
1
50
50

F
H
G
I
K
J = 1 0.98
50
= 0.6358 or 63.6%
Example 8.6 (d) The maximum annual floods for the river Tapti at Ukai were statistically
analysed for a period of 93 years (1876-1968). The mean annual flood and the standard devia-
tion are 14210 and 9700 cumec, respectively.
Determine:
(i) The recurrence interval of the highest flood 42500 cumec (in 1968) by Weibulls method
and what its percentage chance of occurring in (a) in any year, (b) in 10 years ?
(ii) What is the recurrence interval of the design flood adopted by CWPC (49500 cumec)
and the highest flood (42500 cumec) by Gumbels method?
Solution For the highest flood, its rank m = 1
(i) Weibull: T =
n
m
+ 1
=
93 1
1
+
= 94 yr
(a) P =
1
T
=
1
94
= 0.01065 or 1.065%
i.e., its chance of occurrence in any year is ~_ 1%
(b) P
Ex
= 1 (1 P)
N

= 1 1
1
94
10

F
H
G
I
K
J = 0.1014 or 10.14%, i.e., 10% chance.
(ii) From Gumbels Eqn. (8.17 a):
(a) Design flood Q
DF
= 49500 cumec = Q
T
, Q = 14210 cumec
Q
T
=
Q
+ (0.78 ln T 0.45), for n > 50
49500 = 14210 + 9700 (0.78 ln T 0.45)
ln T = 5.241, T = 189, say 190 yr
against Weibulls 50 yr, Fig. 8.4
(b) Highest flood Q
MF
= 42500 cumec = Q
T
42500 = 14210 + 9700 (0.78 ln T 0.45)
ln T = 4.316, T = 75 yr, against Weibulls 30 yr, Fig. 8.4
Gumbel Frequency Distribution: Resume of formulae:
For large values of n, (n > 50):
P = 1 e
e
y


, T =
1
P
=
1
1


e
e
y
y
T
= ln . ln
T
T
L
N
M
O
Q
P
1
...(8 14a)
y
T
= 0 834 2 303
1
. . log . log +

L
N
M
O
Q
P
T
T
...(8.14b)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 237
FLOODSESTIMATION AND CONTROL 237
y =
1
078 .
(X X + 0.45 ), y = y
T
, X = Q ...(8.14)
or, y =
12825 . ( ) X X

+ 0.577 ...(8.14c)
i.e., y =
a X X ( )

+ b, a = 1.2825, b = 0.577 ...(8.14d)


X
T
= X + (0.78 y 0.45) ...(8.17)
X
T
= X + (0.78 ln T 0.45) ...(8.17a)
X
T
=
X
+ (1.8 log T 0.45). ...(8.17b)
Example 8.6 (e) Statistical analysis of the annual floods of the river Tapti (1876-1968) using
Gumbels method yielded the 100-yr and 10-yr floods as 42800 and 22700 cumec, respectively.
Determine:
(a) the magnitude of a 20-yr flood.
(b) the probability of a flood of magnitude 35000 cumec (i) occurring in the next 10 years,
(ii) in the next year itself.
Solution Eq. (8.14a): y
10
= ln . ln
10
9
= 2.25, X
10
= 22.7 tcm
y
100
= ln . ln
100
99
= 4.6 , X
100
= 42.8 tcm
Eq. (8.14d): 2.25 =
a X ( . ) 22 7

+ b ...(i)
4.6 =
a X ( . ) 42 8

+ b ...(ii)
(ii)(i): 2.35 = 20.1
a

= 20.1
12835
2 35
.
.
= 10.969 tcm
From Eq. (8.14c): 22.7 X = (2.25 0.577)
10 969
12825
.
.
= 14.309
X = 22.7 14.309 = 8.391 tcm
(a) Eq. (8.14a): y
20
= ln . ln
20
19
= 2.97
Eq. (8.14c): 2.97 =
12825
10 969
.
.
(X
20
8.391) + 0.577
X
20
= 28.856 tcm or 28856 cumec
Alternatively, Eq. (8.17a): X
20
= 8.391 + 10.969 (0.78 ln 20 0.45) = 29 tcm, or 29000 cumec
(b) Eq. (8.14c): y
T
=
12825
10 969
.
.
(35 8.391) + 0.577 = 3.6881
Eq. (8.14a): ln . ln
T
T 1
= 3.6881
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 238
238 HYDROLOGY
T = 41 yr, P =
1
T
= 0.0244
Alternatively, P = 1 e
e
y


= 1 e e
e

=
3 6881
1
0.025
.
= 1 0.9753 = 0.0247
T =
1
P
=
1
0 0247 .
= 40.5, say 40 yr
(i) P
Ex
= J
(41, 10)
= 1 (1 0.0244)
10
= 0.2188, say 22%
(ii) P
Ex
= J
(41, 1)
= (1 0.0244)
1
= 0.0244, or 2.44% chance
Example 8.6 (f) The annual floods for a large period were statistically analysed by Gumbels
methods, which yielded
Q
= 19000 cumec, = 3200 cumec.
Determine
(a) the probability of a flood magnitude of 30000 cumec occurring in the next year.
(b) the flood magnitude of 5-yr return period.
Solution (a) y =
12825
3200
.
(30000 19000) + 0.577 = 5.5
P = 1 e
e
y


= 1 e
0.0067
= 1 0.9901 = 0.0099 ~_ 1%
P
Ex
= 1 (1 0.0099)
1
= 0.0099 ~_ 1%
(b) T = 5, P =
1
5
= 1 e
e
y


, y = 0.079
0.079 =
12825
3200
.
(X 19000) + 0.577, X = 17758 cumec
8.6 METHODS OF FLOOD CONTROL
A flood is an unusual high stage of a river overflowing its banks and inundating the marginal
lands. This is due to severe storm of unusual meteorological combination, sometimes com-
bined with melting of accumulated snow on the catchment. This may also be due to shifting of
the course of the river, earthquake causing bank erosion, or blocking of river, or breaching of
the river flood banks. Floods have swept vast regions in India, particularly in the basins of
rivers Kosi, Brahmaputra, Godavari, Narmada and Tapti. Floods cause much loss of life and
property, disruption of communication, damage to crops, famine, epidemic diseases and other
indirect losses.
Design magnitudes of floods are needed for the design of spillways, reservoirs, bridge
openings, drainage of cities and air ports, and construction of flood walls and levees (flood
banks). The maximum flood that any structure can safely pass is called the design flood.
The damages due to the devastating floods can be minimised by the following flood
control measures, singly or in combination.
(i) by confining the flow between high banks by constructing levees (flood banks) ,
dykes, or flood walls.
(ii) by channel improvement by cutting, straightening or deepening and following river
training works.
(iii) by diversion of a portion of the flood through bypasses or flood ways. In some cases
a fuse plug levee is provided. It is a low section of levee, which when once over topped, will
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 239
FLOODSESTIMATION AND CONTROL 239
wash out rapidly and develop full discharge capacity into the flood-way. In other locations, a
concrete sill, weir or spillway controlled by stop logs or needles may be provided so that the
overflow occurs at a definite river stage. Sometimes dynamiting a section of levee is resorted to
bypass the flood.
(iv) by providing a temporary storage of the peak floods by constructing upstream reser-
voirs and retarding basins (detention basins).
(v) by adopting soil conservation measures (land management) in the catchment area.
(vi) by temporary and permanent evacuation of the flood plain, and flood plain zoning
by enacting legislation.
(vii) by flood proofing of specific properties by constructing a ring levee or flood wall
around the property.
(viii) by setting up flood forecastingshort term, long term, rhythm signals and radar,
and warning centres at vulnerable areas.
Flood Control by Reservoirs
The purpose of a flood control reservoir is to temporarily store a portion of the flood so that the
flood peaks are flattened out. The reservoir may be ideally situated immediately upstream of
the area to be potected and the water discharged in the channel downstream at its safe capac-
ity (known from its stage-discharge curve), i.e., the peak has been reduced by AB, Fig. 8.6. All
the inflow into the reservoir in excess of the safe channel capacity is stored until the inflow
drops below the channel capacity and the stored water is released to recover the storage capac-
ity for the next flood.
Controlled
release
Controlled
outflow
B
A
Peak Reduction = AB
Inflow hydrograph
into reservoir
Safe channel
capacity
=
Time t (days)
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Fig. 8.6 Flood control by reservoirs
If there is some distance between the reservoir and the protected area but no local
inflow between these points, the reservoir operation is similar to the above but the peak will
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 240
240 HYDROLOGY
further be reduced due to storage in the reach downstream from the reservoir. If there is a
substantial local inflow between the dam and the control point, the reservoir must be operated
to produce a minimum peak at the protected area rather than at the dam site; otherwise the
release from a reservoir may unfortunately synchronise at some point downstream with flood
flows from a tributary. Timely and reliable weather forecasts and prompt information about
precipitation upstream and downstream of the reservoir and the means of translation of this
information into necessary flood hydrographs will all help in effective reservoir operation.
Construction of reservoirs for flood control only is rarely economical and other benefits like
irrigation, hydel power, also have to be taken into consideration. It is the modern practice to
construct multipurpose reservoirs, where a space is allocated exclusively for flood control,
usually above the spillway crest level and is made available when required by closing the
spillway crest gates.
The effectiveness of the reservoir in reducing peak flows, increases as its storage capac-
ity increases. The maximum capacity required is the difference in volume between the safe
release from the reservoir and the maximum inflow. Since the hydrograph is wider at low
flows, more water must be stored to reduce the peak by a given amount. As the peak reduction
is increased, more marginal area will be protected from the floods. The benefits accrued by a
unit peak reduction are usually less. Thus, the size of the reservoir has to be determined by
weighing the cost involved in reducing the peak with the benefits accrued. A single reservoir
across the main river may not give the required protection to all towns and cities widely lo-
cated and reservoirs constructed across tributaries are effective in flood protection. In general,
at least one-third of the total drainage area should come under one reservoir for effective flood
control.
Retarding Basins
The release from a storage reservoir is controlled by gates and valves and regulated by the
project engineer. A retarding basin is provided with outlets like a large spillway and sluices
with no control gates. The sluice discharges like an orifice, i.e., Q = C
d
A 2gH , and there is a
greater throttling of flow when the reservoir is nearly full than would a spillway discharging
like a weir, i.e., Q = CLh
3/2
(Fig. 8.7). However, a spillway is necessary for emergency in case of
the flood exceeding the design maximum.
The discharge capacity of a retarding basin when full should equal the safe discharging
capacity of the channel downstream. The storage capacity of the basin should be equal to the
volume of the design flood minus the volume of water released during the flood. A retarding
basin is used only for the purpose of flood control. After the peak of flood has passed, the inflow
will gradually become equal to the outflow. One of the limitations of the retarding basins is
that the discharge from the basin may synchronise with the flood flow of a tributary down-
stream and as such they are constructed on comparatively small stream while storage reser-
voirs are provided across big rivers (since the release can be regulated).
For any pool elevation of the reservoir, the storage and discharge can be calculated. For
a known inflow hydrograph, the corresponding outflow hydrograph can be determined by any
method of flood routing (Chapter 9).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 241
FLOODSESTIMATION AND CONTROL 241
BL
twl
A
Area of c/s
BL
Q
MWL
h
H
Q = C A 2gH + CLh
d
3/2
Crest
Spillway (with no
crest gates) length L
Sluice with bell mouth
(ungated) entry
tail water level
Fig. 8.7 Retarding basin
Construction of Levees
The construction of levees (flood banks or dykes) is extensively followed in India, since it is an
economical, direct and immediate method. The design and construction of levees are similar to
those of an earth dam. The levees are constructed beyond the meander belt of a river, Fig. 8.8 (a)
and they tame a river not to change its course. As far as possible, there should be very few
curves in their alignment. They require constant watch and after the floods recede, repairs
and restoration of levees should be resorted to.
The spacing and height of levees are determined by a series of trials. A height is as-
sumed and the discharge through the proper channel is computed for the assumed high water
flow, which is the level of the top of bank less the free board. This flow subtracted from the
estimated probable maximum flood discharge gives the discharge to be passed over the flood
ways between the proper channel and the levees (Figs. 8.8 (a) and (b), 8.9 and 8.10). Area of
the flood ways is then obtained by dividing it by the velocity of flow. The spacing of levees thus
obtained, should give a minimum value for the cost of levees and the value of the submerged
land in the flood way. The effects of levees on flood flow are:
(i) increase in the rate of flood flow
(ii) increase in the flood water elevation
(iii) increase in the carrying capacity of the channel
(iv) increase in the scouring action
(v) decrease of surface slope of stream above the leveed section
Channel Improvement
Channel improvement increases the discharging capacity of the stream thereby decreasing
the height and duration of the flood. Flood carrying capacity can be increased either by in-
creasing the cross-sectional area or by increasing the velocity along the river. Enlarging the
section is attempted only for narrow and shallow channels with small watersheds, the limit of
such enlargement in width being 30-40 m. Deepening is preferred to widening since the hy-
draulic mean radius increases more with depth (for the same increase in the sectional area)
thus increasing the velocity.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 242
242 HYDROLOGY
Meander
belt
Meandering
river
Levees
(a) Levees along a meandering river
Design flood level
FB
TW
2
2
1
Berms
3
1
1
Berm Revetment
3
1
6
Drain
Borrow pit
Trench
FB - Free board, TW - Top width
(b) Typical levee cross section
Fig. 8.8 Flood control by levees
River
City
Ring levee
Tributary
Diversion
channel
Fig. 8.9 Ring levee to protect a city
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 243
FLOODSESTIMATION AND CONTROL 243
Reservoir
Dam
River d/s
of reservoir
Levee
City
Fig. 8.10 Flood protection by reservoir and levees for a city
The channel velocity (given by Mannings or Chezys formulae) is affected by hydraulic
mean radius, slope of river bed and roughness of the bed and sides. Roughness can be reduced
by
(i) removing sand bars.
(ii) prevention of cropping on river beds near banks.
(iii) removal of fallen trees and other snags.
(iv) elimination of sharp bends of meandars by providing cutoffs (Fig. 8.11).
In a stream, deepening results in the loss of slope as its outlet can not usually be low-
ered. Deepening can be resorted to only when cutoffs are provided, when the slope of the
channel is increased due to the reduction in the length of flow. Thus, a cutoff helps
(i) in increase the velocity by increasing the slope,
(ii) to shorten the path of flow by elimination of meandars, and consequently
(iii) to shorten the levees necessary to confine flood waters.
Elimination of meanders by providing straight cutoffs has been done on the river Mis-
sissippi in USA.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 244
244 HYDROLOGY
Cut-off
Bend gets silted
up later
Fig. 8.11 Cut-off in a meandering river
Example 8.7 A channel has a bottom width of 200 m, depth 6 m and side slopes 1:1. If the
depth is increased to 9 m by dredging, determine the percentage increase in velocity of flow in
the channel. For the same increase in cross sectional area, if the channel is widened (instead of
deepening), what is the percentage increase in the velocity of flow.
Solution Chezys formula, V = C RS
where V = velocity of flow in the channel
R = hydraulic mean radius
S = bed slope of the channel
C = a constant, depending on the roughness of the bed and sides
Assuming the bed slope and roughness are the same in both the cases of deepening and
widening, V R
Case (i) Increasing the depth to 9 m by dredging.
Putting the subscript o for the original area of cross section (A), wetted perimeter (P)
and the hydraulic mean radius (R), i.e., before deepening Fig 8.12,
A
0
= (200 + 1 6)6 = 1236 m
2
P
0
= 200 + 2 6
1 1
2
+
= 217 m
R
0
=
A
P
0
0
1236
217
=
= 5.7 m
After deepening from 6 m to 9 m, Fig. 8.12,
A = (194 + 1 9)9 = 1827 m
2
P = 194 + 2 9
1 1
2
+
= 219.4 m
R =
A
P
=
1827
219.4
= 8.33 m
Velocity increase by deepening =
8 33 570
57
. .
.

100 = 21%
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-2.PM5 245
FLOODSESTIMATION AND CONTROL 245
Free
board
F.S.L.
1
1
1
2
Initial
channel
Channel
deepened
200 m
194 m
3 m
6 m
1
1
1 HMD = 5.7 m
2 HMD = 8.33 m
DV = 100
8.33 5.70
5.7
= 21%
Fig. 8.12 Channel improvement by deepening (Example 8.7)
Case (ii) For the same increase in the cross sectional area, widening the channel,
Let the bottom width after widening be b.
1827 = (b + 1 6)6
b = 298.5 m
After widening P = 298.5 + 2 6 1 1
2
+ = 315.42 m
R =
A
P
=
1827
315 42 .
= 5.8 m
Velocity increase on widening =
58 57
57
. .
.

100 = 0.84%
Thus, the velocity increase will be only 0.84% on widening as against 21% by deepening.
Hence, exploding the river channels at the mouths at the start and ebbing of floods will be
logical proposition.
Silting of river-channels at mouthsIt has been found that the rate of increase in the
HFL is faster than the rate of increase in HFQ due to silt deposits at the mouths of river
channels. Rate of silting on an average on the banks of Narmada (central India) is approxi-
mately 35 cm per year, with 60 cm in 1968 floods. Natural consolidation of silt deposits does
not facilitate conversion to suspended silts at times of flood. However, if the river bed is ex-
ploded at the time of recession of floods, the silt deposits are likely to be transported into the
sea.
8.7 SOIL CONSERVATION MEASURES
The best way to prevent silt deposition is to arrest silt at the place of its origin, i.e., by under-
taking soil conservation measures in the catchment area. Soil conservation measures for the
entire catchment like contour bunds, check dams, terraces, gully plugging, vegetative cover
(strip croping), afforestation, land management, stream bank protection, etc. Fig. 8.13 to 8.18
are very necessary to retard the velocity of runoff, to control soil erosion, to absorb more water
in the soil and to protect the dams and reservoirs from being silted up. For example, a change
in land use by surface vegetation increases the infiltration capacity and reduces surface run-
off. Soil conservation is a subject of its own and Fig. 8.13-8.18 given here illustrate only the
principle, and the reader may refer to standard works on the subject. The choice of the man-
agement practices should be based on information of the hydrologic cycle of the watershed. A
coordinated effort by engineers, agronomists, foresters, geologists, hydrologists and econo-
mists would be very desirable.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 246
246 HYDROLOGY
Land surface
Gulley becomes
deeper and wider if
unchecked
c. Gulley c/s
Gully
(Due to land
erosion)
Retaining
wall
a. Plan
Bottom
of gully
Gulley
Boulders
Retaining
wall
b. c/s of gulley and retaining wall
Fig. 8.13 Gully plugging
Dam
Reservoir
C
Main stream
C
C
C
C
Tributaries
Catchment
area
C-Check dam
a. Plan
b. L/S of stream
Stream bed
Water surface
Check dam
Fig. 8.14 Check dams
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 247
FLOODSESTIMATION AND CONTROL 247
Flood plain zoning Areas, very near to the river are the most vulnerable and therefore
should not be allowed to be used for building houses. They may be used for parks, recreation
grounds, etc. so that inundation of such land may not result in loss of human lives or any
significant damage to property. Raising place for habitations above flood heights can be viewed
as an adjunct to embankments.
GW
cul
cul
cul
cul
c
c
c
c
C-Contours
Cul-Cultivated
Gw-Grass waterway
Strips of close-growing
crops (grasses & legumes)
Fig. 8.15 Contour farming
3-7.5 m 3-6 m
Filling
Excavation
40-50 cm
Original land slope
Fig. 8.16 Contour terrace
1
1
2
1
Contour trenches at
certain vert. interval
Tree planted in trench @
1.5 m
c.c.
Bank
Land slope
Fig. 8.17 Contour trenching
8.8 FLOOD CONTROL ECONOMICS
In a flood control project, the degree of flood protection (i.e., to the required stage) should be
justified by an economical analysis of the costs involved in raising the structure to the required
heights (say, the height of spillway) and the direct and indirect benefits obtained by flood
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 248
248 HYDROLOGY
protection up to that stage. Generally, the flood stage for which the ratio annual benefits to
cost is a maximum is adopted for the design of the flood protection works (Fig. 8.19). Protection
against floods of rare occurrence is uneconomical because of the large investment (for a small
increase in the benefits) and hence there is always a certain amount of flood risk involved.
Top of bund
Retaining wall
Waste weir
a. Plan
A
A
Land slope
0.9 m
0.6 m
b. c/s of bund on AA
1
1
2
1 1
1
1
2
Fig. 8.18 Contour bund
Max.
benefits
Total benefits 2
1 Total costs
Marginal increase
in benefit
Benefits
Costs
= 1
Design stage of
flood protection
Q
D
Q = Max. feasible flood
peak reduction cumec
P
1
T
o
t
a
l
c
o
s
t
s
,
R
s
.
i
n
c
r
o
r
e
s
2
T
o
t
a
l
b
e
n
e
f
i
t
s
,
R
s
.
i
n
c
r
o
r
e
s
Reduction in flood peak Q (cumec)
Fig. 8.19 Cost-benefit analysis for design stage of flood protection
The flood control costs include:
(i) Capital costs involved in the construction of the structure to the required flood height
(i.e., to offer the required degree of flood protection, say, by a combination of dam-
spillway, levees and channel improvement)
(ii) Interest cost on capital expenditure
(iii) Sinking fund, depreciation and taxes
(iv) Operational expenses and maintenance cost
The benefits of flood control include
(i) Direct or primary benefits accruing from prevention of flood damages to structures
downstream, losses arising from disruption of communication, (and business), loss of life and
property, damage to crops, etc.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 249
FLOODSESTIMATION AND CONTROL 249
(ii) Indirect benefits resulting from the money saved under insurance and Workmens
compensation laws, higher yields from intensive cultivation of protected lands and reduction
in flood-prone epidemic diseases, etc.
Assessment of potential flood damage is an important requirement in any organised
flood control programme. Generally stage-damage curves are plotted to show that damage in a
particular region in relation to the rising flood stages in that reach. Indirect damage by floods
deals with the loss of business and services to community. This is a socioeconomic loss and is
difficult to assess because of the various economic and physical factors involved whereas the
direct damages can be estimated in terms of money value. An assessment of the damages
caused by floods can be made when the data is collected and presented in the following form:
(i) Area affected (km
2
)
(ii) Population affected (lakhs)
(iii) Crops affected
(a) in hectares
(b) value in rupees
(iv) Damage to property
(a) number of houses damaged
(b) cost of replacing or repairing in rupees
(v) Loss of livestock
(a) category number
(b) value in rupees
(vi) Human lives lost
(vii) Damage to public works in rupees
Suitable flood indices have to be developed from year to year to enable comparison to be
made of the various flood damages.
Combination of Flood Control Measures
The object of a flood-control study is to decide which of the flood control measures, singly or in
combination, are most suited and their location, size, design and costs. The design of flood
control works should be closely related to the hydrological features and economic justification
of the project.
Suppose the flood control project involves the construction of a reservoir, levees and
channel improvement works, the factors governing the final selection of various combinations
are illustrated in Fig. 8.20. The cost of construction of reservoir to reduce the design flood to
various lower peaks is indicated by curve (1). The cost of construction of levees and other
channel improvement works for protection against various flood peaks is indicated by curve
(2). The sum of the ordinates of the two curves indicates the combined cost of flood protection
by reservoirs, levees and channel improvement works and is given by the curve (3). The
minimum point P of the combined cost curve represents the most economic combination. The
reduced flood peak and the total cost of works can be read off at this point.
See also Appendix-C: Reservoir Design Studies.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 250
250 HYDROLOGY
Min.
cost
3 Combined cost
1
Cost of
reservoir
Total cost of
project
2 Cost of
levee &
channel
improvement
Design
flood peak
2
C
o
s
t
o
f
l
e
v
e
e
&
C
h
-
i
m
p
.
(
R
s
.
i
n
c
r
o
r
e
s
)
1
C
o
s
t
o
f
r
e
s
e
r
v
o
i
r
(
R
s
.
i
n
c
r
o
r
e
s
)
3
C
o
s
t
o
f
p
r
o
j
e
c
t
(
R
s
.
i
n
c
r
o
r
e
s
)
Peak flood Q (1000 cumec)
Q
D
P
Fig. 8.20 Cost analysis for combination of flood control measures
Example 8.8 The costs of construction of levees for flood protection for various flood peaks are
given below. From this and other data given, make an economic analysis of the flood control
project and determine the flood peak for which the levees have to be designed.
Flood peak Total damage Recurrence interval Annual project
(1000 cumec) under the flood of flood peak cost up to the
peak (yr) flood peak
(Rs. in crores) (Rs. in crores)
10 0 2 0.2
15 2 10 0.4
20 5 20 0.6
25 8 30 0.8
30 12 42 1.0
35 20 60 1.3
40 32 80 1.6
50 46 150 1.8
60 70 300 2.0
70 98 600 2.4
Solution The economic analysis is made as shown in Table 8.5 on the basis of benefit-cost
ratio.
The ratio of benefit to cost is a maximum of 1.39 when the levees are constructed to
safely pass a flood peak of 40000 cumec (Fig. 8.21). Hence, the levees designed for this flood
peak will be most economical.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 251
FLOODSESTIMATION AND CONTROL 251
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0 10 20 30 40 50 60 70 80 90 0 100
Flood peak Q, cumec
2
1
3
Annual
benefits
Annual
costs
Design flood
peak
Benefit
Cost
ratio
Benefit
Cost
ratio = 1.37
maximum
Flood protection
by levees
3
B
e
n
e
f
i
t
-
c
o
s
t
r
a
t
i
o
1
A
n
n
u
a
l
b
e
n
e
f
i
t
s
,
R
s
.
i
n
c
r
o
r
e
s
2
A
n
n
u
a
l
c
o
s
t
s
,
R
s
.
i
n
c
r
o
r
e
s
Fig. 8.21 Benefit-cost analysis (Example 8.8)
8.9 FLOOD FORECASTING AND WARNING
The flood forecasts are issued on the basis of the analysis of weather charts and indicate the
likelihood of heavy rainfall over the specified areas with the next 24 to 48 hours. All India
forecasts are prepared every day at Poona.
Radar is very effective in the detection and tracking of severe storms. Meteorological
satellites give an excellent idea of the cloud cover over the whole of India and neighbouring
countries.
After the formulation of forecast, it must be dessiminated amongst persons concerned
at the fastest speed. This can be done by utilising all available media of communications like
telegraph, teleprinter, telephone and wireless and organising a hierarchy for onward trans-
mission, if necessary.
One of the methods of forecasts in The Bureau of Meteorology, Australia comprises the
following procedural steps:
(i) Collection of previous 24-hour rainfall in respect of each catchment
(ii) Updating the Anticident Moisture Index
(iii) Working out the average depth of rainfall
(iv) Assessment of likely extent of the rain from weather charts
(v) Collection of river stages
(vi) Issue of preliminary warnings with all factual data collected at every 6-hour interval;
the final advice is issued using the crest relationship.
A schematic diagram of the flood forecasting and warning system contemplated for the
Tapti basin (central India) is given in Chart 8.1.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 252
252 HYDROLOGY
F
l
o
o
d

p
e
a
k
T
o
t
a
l

d
a
m
a
g
e
I
n
c
r
e
m
e
n
t

o
f
R
e
c
u
r
r
e
n
c
e
I
n
c
r
e
m
e
n
t
A
n
n
u
a
l

b
e
n
e
f
i
t
T
o
t
a
l

a
n
n
u
a
l
A
n
n
u
a
l

p
r
o
j
e
c
t
R
a
t
i
o

a
f
(
1
0
0
0

c
u
m
e
c
)
f
o
r

t
h
e

p
e
a
k
d
a
m
a
g
e
i
n
t
e
r
v
a
l

o
f
i
n

r
e
c
u
r
r
e
n
c
e
f
r
o
m

p
r
o
t
e
c
-
b
e
n
e
f
i
t
s

f
r
o
m
c
o
s
t

f
o
r

t
h
e
b
e
n
e
f
i
t
(
R
s
.

c
r
o
r
e
s
)
(
R
s
.

c
r
o
r
e
s
)
f
l
o
o
d

p
e
a
k
i
n
t
e
r
v
a
l
t
i
o
n

o
f

i
n
c
r
e
-
p
r
o
t
e
c
t
i
o
n

f
o
r
f
l
o
o
d

p
e
a
k
t
o

c
o
s
t
(
Y
r
)
(
Y
r
)
m
e
n
t
a
l

d
a
m
a
g
e
f
l
o
o
d

p
e
a
k
(
R
s
.

c
r
o
r
e
s
)
(
7
)


(
8
)
R
s
.

c
r
o
r
e
s
(
R
s
.

c
r
o
r
e
s
)
(
3
)


(
5
)
1
2
3
4
5
6
7
8
9
1
0
0
2
0
0
.
2
0
2
8
0
.
2
5
1
5
2
1
0
0
.
2
5
0
.
4
0
.
6
2
3
1
0
0
.
3
0
2
0
5
2
0
0
.
5
5
0
.
6
0
.
9
2
3
1
0
0
.
3
0
2
5
8
3
0
0
.
8
5
0
.
8
1
.
0
6
4
1
2
0
.
3
3
3
0
1
2
4
2
1
.
1
8
1
.
0
1
.
1
8
8
1
8
0
.
4
4
3
5
2
0
6
0
1
.
6
2
1
.
3
1
.
2
5
1
2
2
0
0
.
6
0
4
0
3
2
8
0
2
.
2
2
1
.
6
1
.
3
9
1
4
7
0
0
.
2
0
5
0
4
6
1
5
0
2
.
4
2
1
.
8
1
.
3
4
2
4
1
5
0
0
.
1
6
6
0
7
0
3
0
0
2
.
5
8
2
.
0
1
.
2
9
2
8
3
0
0
0
.
0
9
7
0
9
8
6
0
0
2
.
6
7
2
.
4
1
.
1
0
T
a
b
l
e

8
.
9

E
c
o
n
o
m
i
c

a
n
a
l
y
s
i
s

o
f

f
l
o
o
d

c
o
n
t
r
o
l

b
y

c
o
n
s
t
r
u
c
t
i
n
g

l
e
v
e
e
s

(
E
x
a
m
p
l
e

8
.
8
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 253
FLOODSESTIMATION AND CONTROL 253
Wireless sets in
vulnerable areas-
10 nos.
Municipal
authorities
Shahada
Dhulia
Malegaon
Akola
Talegaon
Chalisgaon
Burhanpur
Bhusaval
Nanded
Sindkheda
Taloda
Ukai
Kakrapur
Kathor
Flood forecasting
cell surat
Focal officer
Collecter
Burhanpur
Bhusaval
Nanded
Sindkheda
Taloda
Ukai
Kakrapur
Kathor
Khandwa
Surat
Municipal
authorities
D.S.P.
Stream gauging &
wireless stns. u/s
Raingauge stns.
in catchment
Radio wind &
radio sonde stns.
Chart 8.1 Flood forecasting system in Tapti basin (after B.S. Rao, 1969)
The flood warning system basically means the working out of the flood hydrograph at a
given point sufficiently in advance, given the flood hydrograph of some gauge or gauges suffi-
ciently upstream, taking into consideration.
(i) the effect of the incidence of rainfall forecast for or that has fallen in the intervening
catchment and the consequent contribution of floods enroute, and
(ii) the moderation affected by the valley storage from the upstream gauge to the point
under consideration.
The flood warning system is prepared by
(i) forecasting crest height and time.
(ii) flood routing techniques.
With a properly developed system of scientific flood forecasting and warning, human
toll and destruction to movable properties could be greatly mitigated.
SummaryThe various steps involved in the design of a flood control project are:
(i) Determination of the project design flood and flood characteristics of the basin.
(ii) Assessment of flood damages for different flood stages and socio-economic problems
involved.
(iii) Field survey of flood-prone areas and defining areas to be protected.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 254
254 HYDROLOGY
(iv) Determination of the possible methods of flood protection.
(v) If flood control is feasible by construction of reservoirs and levees, selection of suit-
able sites and their physical characteristics.
(vi) Design details of the flood control structures proposed and preparation of cost esti-
mates.
(vii) For a combination of flood control measures, selection of a flood peak that offers the
desired protection at minimum cost.
(viii) Making the cost-benefit analysis of the project and its economic justification.
(ix) Development of a scientific flood forecasting and warning system.
(x) Preparation of a detailed project report, indicating the alternative flood control meas-
ures explored, the combination finally selected with the economic justification for the same,
and the degree of flood protection offered.
(xi) Construction of the project proposed after approval and sanction of the budget from
the authority concerned.
OUZ V
I Match the items in A with the items in B (more than one item may fit in B)
A B
(i) Floods (a) South India
(ii) SPF (b) Central India
(iii) Design storm (c) Maharashtra State
(iv) Maximum flood discharge (d) U.S.A.
(v) Ryves formula (e) Flood frequency as a factor in flood-estimation
(vi) Dickens formula (f) Flood control
(vii) Inglis formula (g) Construction of a cofferdam
(viii) Fullers formula (h) twice coefficient of variation (2C
v
)
(ix) Creagers formula (i) Increase HMD by deepening
(x) Annual flood series (j) Rational formula
(xi) Partial duration series (k) Moisture adjustment
(xii) Coefficient of skew, C
s
(l) Spillway design flood
(xiii) Retarding basins (m) High intensity of rainfall
(xiv) Channel improvement (n) 80% of MPF
II Say True or False; if false, give the correct statement:
(i) Floods are caused by succession of high intensity storms on a basin.
(ii) The design flood is taken as the maximum probable flood that may occur on a basin.
(iii) The maximum probable flood includes the extremely rare and catastrophic floods and is
usually considered for the spillway design of very high dams.
(iv) The standard project flood is a fare estimate of the flood resulting from the most severe
combination of meteorological and hydrological conditions of the basin.
(v) The PMP is derived from the most critical combination of storms and moisture adjustment
which, after minimising losses, when applied on the design unit hydrograph for the basin,
will produce the MPF.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 255
FLOODSESTIMATION AND CONTROL 255
(vi) The MPF for a basin is usually around 80% of the SPF.
(vii) In flood control project, 100% flood protection is provided and hence there is absolutely no
flood risk.
(viii) In a partial duration series, there may be 23 high floods of the same year and does not give
a true distribution series.
(ix) Annual series are useful during the construction period of a large dam project, while the
partial duration series are preferred for the spillway design flood.
(x) The critical (design) intensity of rainfall occurs when the duration of storm is more than the
concentration time.
(xi) When enough storm data for a basin is not available, the PMP is estimated by storm transpo-
sition from a neighbouring catchment which is meteorologically homogeneous.
(xii) The Gumbel distribution provides a satisfactory fit for partial duration foods or rainfall data.
(xiii) While the annual floods are plotted against their probability of their occurrence in 100 years,
the partial duration floods are plotted against percentage of time.
(xiv) In channel improvement (for flood control), widening is preferred to deepening.
(xv) While Radar gives an excellent idea of cloud cover, the meteorological satellites are very
effective in the detection and tracking of severe storms.
(xvi) A flood forecasting and warning system basically means working out of the flood hydrograph
at a given point sufficiently in advance, given the flood hydrographs at sufficiently upstream
point/s.
(xvii) The design flood is usually selected after making a cost-benefit analysis.
(xviii) Land management is ineffective in flood control.
(xix) If a certain flood occurs once in 50 years, then its chance of occurring in any one year is 2%.
(xx) Generally, the flood stage (flood peak) for which the ratio of annual benefits to cost is a
maximum is adopted for the design of flood protection works.
(xxi) The 100-pr flood will be equalled or exceeded 10 times in a 1000 year period.
(xxii) Protection against rare floods is uneconomical and hence there is always a certain amount of
flood risk involved.
(xxiii) The first to suggest that frequency should be considered as a factor in estimating flood was:
(a) Allen Hazen (b) Gumbel
(c) Fuller (d) Weibull
(false: ii, vi, vii, ix, x, xii, xiii, xiv, xv, xviii)
III Classify the following into tangible (direct) and intangible (indirect) benefits due to flood control.
(i) Prevention of damage to structures
(ii) Loss of life and property
(iii) Money saved under insurance and Workmens Compensation Laws
(iv) Higher yields from intensive cultivation of protected lands
(v) Elimination of losses arising from interruption of business (due to disruption of communica-
tion)
(vi) Reduction in flood-prone epidemic diseases
(vii) Damage to crops.
IV Choose the correct statement/s in the following:
1 The methods of estimating high flood discharge are
(i) by applying PMP on the design unit hydrograph for the basin.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 256
256 HYDROLOGY
(ii) By empirical formulae developed for the regions.
(iii) By applying rational formula.
(iv) By flood frequency studies.
(v) By stochastic methods.
(vi) From the percent flood risk that can be allowed in the project.
(vii) All the above methods.
2 The methods of mitigating floods are
(i) by construction of reservoirs across tributaries
(ii) by construction of a large reservoir across the main stream
(iii) by construction of a retarding basin across a large river with a tributary joining the river
downstream
(iv) by construction of levees, flood banks and dykes
(v) by channel improvement
(vi) by land management
(vii) by temporary evacuation of low lying areas and flood warnings
(viii) all the above methods.
3 The design flood is taken as
(i) flood peak derived by applying PMP on the design unit hydrograph
(ii) 80% (approx.) of MPF
(iii) SPF
(iv) the flood of the recurrence interval corresponding to the percent risk that can be allowed in
the project
(v) the flood stage for which the ratio of benefit to cost is maximum
(vi) the 25-year flood for a land drainage project
(vii) the 160-year flood for a spillway design or bridge
(viii) all the above. (1except vi, 2i, iv, v, vi, vii; 3 vii).
OUE8TON8
1 (a) Explain design flood. Is this the same as maximum probable flood ?
(b) What are the methods of estimating maximum flood discharge? Give three formulae for maxi-
mum flood estimation in India indicating for which part of the country they are applicable.
(c) Find the value of the constants C and n in the empirical formula Q = CA
n
*, where Q is the
flood discharge in cumec and A is the catchment area in km
2
from the following data:
A (km
2
): 4 10 50 100 200
Q (cumec): 100 158 354 500 706
(Hint Plot Q vs. A on log-log paper; C = 50intercept; n = 0.5 slope of straight line;
Q = 50 A )
2 The design storm for a basin has the depth of rainfall for successive hours as 5.6, 7.6 and 5.2 cm.
The 1-hr design unit hydrograph for the basin may be approximated by a triangle of base 6 hours
with a peak of 60 cumec occurring at the 2nd hour from the beginning. Compute the flood
hydrograph assuming an average loss rate of 0.5 cm/hr. Base flow may be neglected.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 257
FLOODSESTIMATION AND CONTROL 257
3 (a) Explain the following terms with reference to frequency studies:
(i) Annual series (ii) Partial duration series
(iii) Recurrence interval
(b) At a particular gauging station, the annual maximum floods are recorded from 1951 to 1975.
The mean and standard deviation of these floods are 310.24 cumec and 110.54 cumec, respec-
tively. Assuming that the flood series follow Gumbels distribution, determine the flood
magnitudes for the recurrence intervals of 200, 100, 50 and 25 years. Plot these points on the
Gumbels probability paper.
4 (a) Differentiate: deterministic, probabilistic and stochastic processes in estimation of maxi-
mum annual rainfall or flood.
(b) Records of peak flow are available for a river at a station where a reservoir is to be con-
structed for a period of 75 years. The arithmetic mean of the peaks is 8200 cumec and the
standard deviation is 3170. Making use of Gumbels method determine the recurrence inter-
val for a flood of 18400 cumec.
5 (a) Define Recurrence interval and Frequency as applied to annual floods or rainfall.
(b) What should be the recurrence interval of a flood such that the probability of its occurrence
in a 10-year period is 0.01?
(c) The mean of the annual maximum floods at a gauging station with 40 years of records is
1300 cumec and the variance is 1620 cumec. Estimate the magnitude of the 100-year flood.
(Hint: variance = square of standard deviation,
2
)
6 The annual flood peaks for Nagavalli river at Thottapalli are given for the period 1930-1950.
(i) Plot the recurrence interval versus flood peak
(ii) From the plot, determine the magnitudes of 50-yr and 100-yr floods.
(iii) What is the recurrence interval of a flood magnitude of 300 cumec?
Year Flood (cumec) Year Flood (cumec)
1930 1065 1941 910
31 645 42 750
32 1005 43 930
33 1350 44 750
34 860 45 1070
35 150 46 830
36 2260 47 1095
37 650 48 384
38 2840 49 2230
39 990 1950 3210
1940 870
7 The maximum annual floods for a river for 26 years are given below:
(i) Plot the frequency curve.
(ii) Determine the magnitude of a 100-yr, 50-yr and 20-yr floods.
(iii) What is the recurrence interval of a flood of 300 cumec?
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 258
258 HYDROLOGY
Year Flood (cumec) Year Flood (cumec)
1955 375 1968 219
56 199 69 490
57 232 70 233
58 419 71 141
59 245 72 256
60 411 73 308
61 166 74 575
62 232 75 229
63 206 76 260
64 232 77 387
65 238 78 283
66 440 79 221
1967 180 1980 250
8 The maximum annual floods for a river for 60 years were statistically analysed. The sixth larg-
est flood (i.e., No. 6 when arranged in the descending order of flood magnitude) was 480 cumec.
Determine:
(i) the period in which the flood (i.e., 480 cumec) may reoccur;
(ii) the percentage chance that the flood (i.e., 480 cumec) may occur in any one year.
(iii) the percentage chance that the flood (i.e., 480 cumec) may not occur in the next 20 years.
(iv) the probability that the flood (i.e., 480 cumec) may occur in the next 10 years.
9 (a) What do you understand by degree of protection in relation to a flood control scheme and
what factors govern the degree of protection to be offered ?
(b) What is the probability that only one flood equal to or exceeding the 50-year flood will occur
in a 50-year period? What is the probability that one or more floods equal to or exceeding the
50-year flood will occur in a 50-year period? (2, 64%)
10 (a) Discuss the validity of the probability method of flood estimation. List the demerits, if any.
(b) Compute the magnitude of the return period of a design flood to provide 60% assurance that
failure of a structure would not occur. (2
1
2
year)
11 What return period must a highway engineer assume in his design of a culvert, if he allows a
10% risk that flooding will occur in the next 5 years? (48.1 yr)
12 Explain briefly how you would compute the design flood for a spillway in a reservoir. Assume
that rainfall-runoff data are available for the basin for about 50 years. You may list out the
various methods available and explain any one of them.
13 The maximum annual floods for River Tapti for 93 years (1876 to 1968) were statistically ana-
lysed, and 17 highest annual floods are given below. Draw the frequency curve and determine:
(i) the recurrence interval of the highest flood, SPF of 48200 cumec and the design flood of
49500 cumec.
(ii) the 200-yr, 150-yr, 100-yr and 75-yr flood magnitude.
(iii) the probability that the flood of 37300 cumec (a) may not occur in the next 10 years (b) may
occur in any one year; examine how for case (a) is true.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 259
FLOODSESTIMATION AND CONTROL 259
Maximum annual floods (when water levels at Surat exceeded gauge level 95)
of river Tapi during 1876 to 1968
Year Month and date Peak flood
(1000 cumec)
1876 Aug. 29 to Sept. 5 21.2
1882 Sept. 12 21.8
1883 July 3 30.2
1884 Sept. 9 24.9
1894 July 22 23.6
1914 Sept. 17 21.8
1930 Sept. 30 22.6
1933 Sept. 18 25.5
1937 Sept. 10 20.0
1942 Aug. 6 22.8
1944 Aug. 18 & 24 (2 peaks) 29.3
1945 Sept. 24 24.2
1949 Sept. 17 18.3
1958 Sept. 2 19.6
1959 Sept. 17 37.3
1962 Sept. 15 22.6
1968 Aug. 6 42.5
Hint Since all the 93 annual floods are not given, it is not possible to determine Q and for
Gumbels method and hence draw the frequency curve of Weibulls.
(94, 180, 210 yr; 49, 46, 43, 40 T cumec; 14.8, 85.2% but has been exceeded in 1968 after 9 years).
PDS cannot be applied since there are only 17 events in 93 years.
14 (a) Explain the different methods of avoiding damage by floods
(b) Explain with a neat sketch how flood control is effected by reservoirs with regard to (i) their
number, (ii) location, (iii) size, and (iv) operation.
(c) Is land management effective in flood control?
15 (a) Explain the tangible and non-tangible benefits due to flood control.
(b) Suppose that a flood control project is to be a combined one and involves the construction of
a reservoir and levees with channel improvement, explain how would you determine the
most economic combination of these procedures.
(c) Given below is the information regarding flood stage, recurrence interval, total damage and
cost of project for giving protection against indicated stage. Work out the benefit-cost ratio
and net benefits (i.e., benefits costs). What is the peak stage against which you would
choose to provide protection?
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 260
260 HYDROLOGY
Peak Total damage Return period Annual cost of
stage below indicated (years) project
(m) stage (Rs. in millions)
(Rs. in millions)
9 0 7 0.8
10 8 10 1.2
11 20 15 1.6
12 40 22 2.0
13 64 30 2.6
14 90 70 3.2
15 120 150 3.6
16 160 300 4.0
16 (a) Explain stage by stage the studies to be made and the field work to be undertaken for prepar-
ing an estimate and report for a flood control project.
(b) Write a note on flood forecasting and warning.
17 Write short notes on:
(a) PMP (b) Flood forecasting and warning
(c) Rational formula for flood estimation (d) Design flood
(e) Moisture adjustment (f) Retarding basin
(g) Fuse plug levee (h) Storm transposition
(i) Flood embankment
18 Statistical analysis of an annual flood series for the period 18761968 at a station X on the river
Tapti shows that the 100-yr flood has a magnitude of 42800 cumec and a 10-yr flood a magni-
tude of 22700 cumec. Assuming that the flood peaks are distributed according to the theory of
extreme values, determine
(a) the magnitude of a 20-yr flood.
(b) the probability of a flood equal to or greater than 35000 cumec occurring
(i) in the next 10 years,
(ii) in the next year itself.
(c) the probability of having at least one 10 year flood in the next 4 years.
(d) the mean (
Q
) and standard deviation () of the annual floods.
19 A cofferdam has to be built in a river to withstand four consecutive flood seasons (i.e., 4 years)
and offer protection against a 20-yr flood. The annual flood series for a period of 30 years at the
site indicate a maximum flood peak of 8000 cumec and a minimum of 1800 cumec. Assuming
that the annual flood peaks plot as a straight line on a semi-log paper (recurrence interval plot-
ted as abscissa to logarithmic scale), estimate the magnitude of the 20-yr flood (without plotting)
and determine the probability of its occurrence during the life of the cofferdam.
(7200 cumec, 18.6%)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD8-3.PM5 261
FLOODSESTIMATION AND CONTROL 261
20 The annual rainfall distribution during a period of 75 years of record at a place is given below.
Rainfall range No. of years
<15 cm 5
15-24 cm 12
25-34 cm 18
35-44 cm 30
45 cm 10
Determine
(a) the probability of having a rainfall in excess of 45 cm in any one year.
(b) the probability of the rainfall exceeding 45 cm in three successive years,
(c) the probability of occurrence of rainfall of less than 20 cm during the next year.
21 In a tropical area where there are short storms more or less uniformly distributed throughout
the year. there is a 60% chance of rain on any one day. Determine: (i) the probability that there
will be no rain on any two successive days, (ii) the probability that it will rain on both days, and
(iii) that it well rain on only one of the two days.
22 In a certain river, a flood discharge of 2000 cumec was exceeded 48 times during a period of 27
years and a flood of 8000 cumec exceeded twice. Determine their annual probability and average
recurrence interval. (80%, 0.56yr, 7%, 14yr)
23 What return period a Municipal Engineer should adopt in the design of a culvert on a drain, if he
is willing to accept only a 10% risk of being flooded during the 25 years of the expected life of the
culvert? [238 yr]
24 A 45 min storm produces 30 mm of rain over a catchment of 120 ha. If the time of concentration
is 30 min and runoff coefficient is 0.3, estimate the resulting peak flow rate.
[Hint Use eqs. 8.9 & 8.10.] (Ans. 4.663 cumec)
25 The annual floods of a basin were statistically analysed using Gumbels distribution which yielded
Q = 32000 cumec, and = 6000 cumec. Determine
(a) the recurrence interval of a flood of magnitude 40000 cumec.
(b) the probability of the above flood occurring in the next 5 years. (Ans. 33.33 yr, 14.1%)
26 The annual floods of River Chambal at Gandhisagar dam were statistically analysed which yielded
the 50-yr and 100-yr floods as 40.8 tcm and 46.3 tcm, respectively. Estimate the 500-yr flood
magnitude. What is the probability that this flood may occur in the next 100 years.
(tcm = 1000 cumec) (Ans. 59 tcm)
27 The annual floods of a river at a particular site were analysed by Gumbels method which yielded
Q
= 1200 cumec and = 650 cumec. For what discharge you design the structure at this site for
95% assurance that the structure would not fail in the next 50 years. (Ans. 4200 cumec)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
9.1 RESERVOIR ROUTING
Flood routing is the process of determining the reservoir stage, storage volume of the outflow
hydrograph corresponding to a known hydrograph of inflow into the reservoir; this is called
reservoir routing. For this, the capacity curve of the reservoir, i.e., storage vs pool elevation,
and outflow rate vs. pool elevation, curves are required. Storage volumes for different pool
elevations are determined by planimetering the contour map of the reservoir site. For exam-
ple, the volume of water stored (V) between two successive contours having areas A
1
and A
2
(planimetered) and the contour interval d, is given by
Cone formula, V =
d
3
(A
1
+ A
2
+ A A
1 2
) ...(9.1)
Prismoidal formula, V =
d
6
(A
1
+ A
2
+ 4A
m
) ...(9.2)
where A
m
=
A A
1 2
2
+
, i.e., area midway between the two successive contours. The prismoidal
formula is more accurate. The outflow rates are determined by computing the discharge through
the sluices and the spillway discharge for different water surface elevations of the reservoir.
(i.e., pool elevations):
Discharge through sluices, Q
sl
= C
d
A 2gh ...(9.3)
Discharge over spillway crest, Q
sp
= CLH
3/2
...(9.4)
Outflow from the reservoir O = Q
sl
+ Q
sp
where h = height of water surface of reservoir above the centre of sluice
H = height of water surface of reservoir above the crest of spillway
C
d
= coefficient of discharge for the sluice
C = coefficient of spillway
A = area of sluice opening
L = length of spillway
The problem in flood routing is to determine the relation between the inflow, the out-
flow and the storage as a function of time. The problem can be solved by applying the hydro-
logic equation
I = O + S ...(9.5)
where I = inflow rate
Chapter 9
FLOOD ROUTING
262
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 263
FLOODS ROUTING 263
O = outflow rate
S = incremental storage, at any instant.
Taking a small interval of time, t (called the routing period and designating the initial
and final conditions by subscripts 1 and 2 between the interval, Eq. (9.5) may be written as
I I
t
O O
1 2 1 2
2 2
+ F
H
G
I
K
J

+ F
H
G
I
K
J t = S
2
S
1
...(9.6)
The routing period, t selected should be sufficiently short such that the hydrograph
during the interval 1-2 can be assumed as a straight line, i.e., I
mean
=
I I
1 2
2
+
.
Eq. (9.6) can be rearranged as
I I
1 2
2
+ F
H
G
I
K
J t + S
1

O t
1
2
= S
2
+
O t
2
2
...(9.7)
After selecting a routing period t, curves of O vs. S, and O vs. S Ot/2 on either side of
O-S curve are drawn. At the beginning of the routing period all the terms on the left side of Eq.
(9.7) are known and the value of the right side terms is found out. Corresponding to this O
2
and (S-Ot/2) are read from the graph, which become the initial values for the next routing
period and so on.
This method of flood routing was developed by LG Puls of the US Army Corps of Engi-
neers and is called the ISD (Inflow-storage-discharge) method. Here it is assumed that the
outflow (i.e., discharge) from the reservoir is a function of the pool elevation provided that the
spillway and the sluices have no gates (i.e., uncontrolled reservoirs) or with constant gate
openings, if provided with control gates for which poor elevation vs. discharge curves are drawn.
Eq. (9.6) may be rearranged as
(I
1
+ I
2
) +
2
1
1
S
t
O
F
H
G
I
K
J =
2
2
S
t
+ O
2
...(9.8)
After selecting a routing period t, a curve of
2S
t
+ O vs. O can be drawn since
2S
t
O +
F
H
G
I
K
J
2O =
2S
t
O, a curve of
2S
t
O vs. O can also be drawn.
At the beginning of the routing period all terms on the left of Eq. (9.8) are known. This
method is called modified puls or Storage Indication Method.
Example 9.1 For a reservoir with constant gate openings for the sluices and spillway, pool
elevation vs storage and discharge (outflow) curves are shown in Fig. 9.1. The inflow hydrograph
into the reservoir is given below:
Time (hr) 0 6 12 18 24 30 36 42
Inflow (cumec) 50 70 160 300 460 540 510 440
Time (hr) 48 54 60 66 72 78 84 90
Inflow (cumec) 330 250 190 150 120 90 80 70
Pool elevation at the commencement = 110 m
Discharge at the commencement = 124 cumec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 264
264 HYDROLOGY
Route the flood through the reservoir by (a) ISD method, and (b) modified Puls method,
and compute the outflow hydrograph, the maximum pool elevation reached, the reduction in
the flood peak and the reservoir lag.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
Outflow O in 100 cumec, Storage S in 10 Mm (or 1000 ha-m)
3
120
118
116
114
112
110
108
106
104
102
100
P
o
o
l
e
l
e
v
a
t
i
o
n
(
m
)
0 400 800 1600 2400 3200 4000 4800 5600 6400
Storage S in cumec day
1
4
p
o
o
l
e
l
e
v
n
v
s
.
S
i
n
1
0
M
.
m
3
p
o
o
l
e
l
e
v
n
v
s
.
S
i
n
c
u
m
e
c

d
a
y
(
c
o
m
p
u
t
e
d
)
1
4
pool elevn
vs. O
in
100
cum
ec
Fig. 9.1 Pool elevation vs. storage and discharge (Example 9.1)
Solution (a) Flood routing by ISD method Take the routing period as 6 hr or
1
4
day. It is easier
to work the flow rates in cumec and the storage volumes in terms of cumec
1
4
day. Hence, the
storage in Mm
3
is converted to cumec
1
4
day by multiplying by 46.3, Table 9.1. Corresponding
to an initial pool elevation of 110 m, O = 124 cumec, S = 49.1 Mm
3
= 49.1 46.3 = 2270 cumec

1
4
day,
Ot
2
=
O
2
t
124
2
cumec
1
4
day = 62 cumec
1
4
day, S +
Ot
2
= 2270 + 62 = 2332 cumec

1
4
day, and S
Ot
2
= 2270 62 = 2208 cumec
1
4
day. First O vs. S curve is drawn. For a
particular O on the S curve,
O
2
abscissa units may be set off on either side of the S curve and
this is repeated for other values of O. The points obtained on either side of S curve plot
S +
Ot
2
and S
Ot
2
curves as shown in Fig. 9.2.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 265
FLOODS ROUTING 265
T
a
b
l
e

9
.
1

T
a
b
u
l
a
t
i
o
n

f
o
r

d
r
a
w
i
n
g

(
i
)

S


O
t
2

a
n
d

(
i
i
)

2
S t


0

c
u
r
v
e
s

f
o
r

r
o
u
t
i
n
g

t
h
e

f
l
o
o
d

t
h
r
o
u
g
h

t
h
e

r
e
s
e
r
v
o
i
r

(
E
x
a
m
p
l
e

9
.
1
)
P
o
o
l
O
u
t
f
l
o
w
S
t
o
r
a
g
e

S
C
o
m
p
u
t
a
t
i
o
n

f
o
r

I
.
S
.
D
.

m
e
t
h
o
d
C
o
m
p
u
t
a
t
i
o
n

f
o
r
e
l
e
v
a
t
i
o
n
O
(
t

=

6
h
r

=

1 4

d
a
y
)
m
o
d
i
f
i
e
d

P
u
l
s

m
e
t
h
o
d
(
m
)
(
c
u
m
e
c
)
(
M
m
3
)
(
c
u
m
e
c


1 4

d
a
y
*
)
O
t
2
S

+

O
t
t
S


O
t
2
2
S
t
2
S
t

+

O
2
S
t


O
(
c
u
m
e
c

(
c
u
m
e
c

(
c
u
m
e
c

(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
1 4

d
a
y
)
1 4

d
a
y
)
1 4

d
a
y
)
1
0
0
6
0
8
.
7
4
0
0
3
0
4
3
0
3
7
0
8
0
0
8
6
0
7
4
0
1
0
2
7
0
1
5
.
1
7
0
0
3
5
7
3
5
6
6
5
1
4
0
0
1
4
7
0
1
3
3
0
1
0
4
8
6
2
3
.
4
1
4
8
0
4
3
1
1
2
3
1
0
3
7
2
1
6
0
2
2
4
6
2
0
7
4
1
0
6
1
0
0
3
2
.
0
1
4
8
0
5
0
1
5
3
0
1
4
3
0
2
9
6
0
3
0
6
0
2
8
6
0
1
0
8
1
1
0
4
0
.
0
1
8
5
0
5
5
1
9
0
5
1
7
9
5
3
7
0
0
3
8
1
0
3
5
9
0
1
1
0
1
2
4
4
9
.
1
2
2
7
0
6
2
2
3
3
2
2
2
0
8
4
5
4
0
4
6
6
4
4
4
1
6
1
1
2
1
3
8
5
8
.
3
2
7
0
0
6
9
2
7
6
9
2
6
3
1
5
4
0
0
5
5
3
8
5
2
6
2
1
1
3
3
1
0
6
3
.
0
2
9
2
0
1
5
5
3
0
7
5
2
7
6
5
5
8
4
0
6
1
5
0
5
5
3
0
1
1
4
5
5
0
6
8
.
3
3
1
6
0
2
7
5
3
4
3
5
2
8
8
5
6
3
2
0
6
8
7
0
5
7
7
0
1
1
5
8
0
0
7
3
.
5
3
4
0
0
4
0
0
3
8
0
0
3
0
0
0
6
8
0
0
7
6
0
0
6
0
0
0
1
1
6
1
0
3
0
7
8
.
8
3
6
5
0
5
1
5
4
1
6
5
3
1
3
5
7
3
0
0
8
3
3
0
6
2
7
0
1
1
7
1
2
8
0
8
3
.
8
3
8
8
0
6
4
0
4
5
2
0
3
2
4
0
7
7
6
0
9
0
4
0
6
4
8
0
1
1
8
1
5
2
0
9
0
.
0
4
1
6
0
7
6
0
4
9
2
0
3
4
0
0
8
3
2
0
9
8
4
0
6
8
0
0
1
2
0

1
0
1
.
0
4
6
8
0

*
1

c
u
m
e
c


1 4

d
a
y

=

1


6
0

=

2
1
6
0
0

m
3
.

1

m
i
l
l
i
o
n

m
3

(
M
m
3
)

=

1
0
6
/
2
1
6
0
0

=

4
6
.
3

c
u
m
e
c


1 4

d
a
y
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 266
266 HYDROLOGY
1400 1800 2200 2600 3000 3400 3800 4200 4600
Storage S, S +
Ot
2
and S
Ot
2
O
u
t
f
l
o
w
O
(
c
u
m
e
c
)
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
O
v
s
S
O
v
s
(
S

)
O
t
2
O
v
s
(
S
+
)
O
t
2
cumec day
1
4
Fig. 9.2 Reservoir routing by ISD method (Example 9.1)
For routing the flood by the I.S.D. method, Table 9.2, for the known outflow at the
commoncement of 124 cumec, S
Ot
2
is read from the curve as 2208 cumec
1
4
day and to this
I I
1 2
2
+
t =
50 70
2
+
cumec
1
4
day = 60 cumec
1
4
day is added to get the right hand side of Eq.
(9.7); i.e., S +
Ot
2
= 2268 and corresponding to this O = 120 cumec is read from the graph which
is the outflow at the beginning of the next routing period. Corresponding to this O = 120
cumec, the pool elevation of 109.2 m is read from the pool elevations vs. O curve. Correspond-
ing to this O = 120 cumec, S
Ot
2
= 2040 is read from the graph and
I I
1 2
2
+
t =
70 160
2
+
t
= 115 cumec
1
4
day is added to get S +
Ot
2
= 2155 for which O is read as 116 cumec and pool
elevation as 108.4 m. Thus the process is repeated till the flood is completely routed through
the reservoir and the outflow hydrograph is obtained as shown in Fig. 9.3.
(b) Flood routing by modified Puls method: Corresponding to the initial pool elevation of
110 m, O = 124 cumec, S = 2270 cumec
1
4
day,
2S
t
=
2 2270 cumec day
day
1
4
1
4
= 4540 cumec,
2S
t
+ O = 4540 + 124 = 4664 cumec and
2S
t
O = 4540 124 = 4416 cumec. Thus, for other
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 267
FLOODS ROUTING 267
values of O, values of
2S
t
+ O and
2S
t
O are computed and O vs.
2S
t
+ O and
2S
t
O curves
are drawn as shown in Fig. 9.4.
Table 9.2 Reservoir routingISD method [Eq. 9.7] (Example 9.1)
Time Inflow
I I
2
1 2
+
t Outflow O S
Ot
2
S +
Ot
2
Pool
(hr) I (cumec- (cumec) (cumec- (cumec- elevation
(cumec)
1
4
day)
1
4
day)
1
4
day) (m)
0 50 124 110.0
60 + 2208 2268
6 70 120 109.2
115 + 2040 2155
12 160 116 108.4
230 + 1960 2190
18 300 119 109.1
380 2020 2400
24 460 122 109.6
500 2080 2580
30 540 130 110.8
525 2380 2905
36 510 195 112.5
475 2730 3205
42 440 395 113.4
385 2820 3205
48 330 395 113.4
290 2920 3110
54 250 335 113.1
220 2790 3010
60 190 265 112.8
170 2760 2930
66 150 210 112.6
135 2740 2875
72 120 170 112.4
105 2720 2825
78 90 145 112.3
85 2700 2785
84 80 132 111.2
75 2650 2725
90 70 130 110.8
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 268
268 HYDROLOGY
0 12 24 36 48 60 72 84 96 108
6 hr routing periods
Time t (hr)
600
550
500
450
400
350
300
250
200
150
100
50
0
I
n
f
l
o
w
o
r
o
u
t
f
l
o
w
(
c
u
m
e
c
)
12 hr
75
cumec
14.5 hr = Reservoir lag
132 cumec = Reduction
in flood peak
Inflow hydrograph
Outflow hydrograph
(ISD method)
Outflow hydrograph
(modified puls method)
F
r
o
m
s
to
r
a
g
e
Equal
areas
To
storage
Fig. 9.3 Reservoir routing (Example 9.1)
0 1000 2000 3000 4000 5000 6000 7000 8000 900010000
2S
t
+ O and
2S
t
O cumec
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
O
u
t
f
l
o
w
O
(
c
u
m
e
c
)
O
v
s
.

O
2
S
t
O
v
s
.
+
O
2
S
t
Fig. 9.4 Reservoir routing by modified Puls method (Example 9.1)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 269
FLOODS ROUTING 269
For routing the flood by the modified Puls method, Table 9.3, corresponding to the initial
pool elevation of 110 m, O = 124 cumec,
2S
t
+ O = 4664 cumec and
2S
t
O = 4416 cumec are
read off. For this
2S
t
O = 4416 cumec, I
1
+ I
2
= 50 + 70 = 120 cumec is added to get the right
hand side of Eq. (9.8), i.e.,
2S
t
+ O = 4416 + 120 = 4536 cumec. For this value of
2S
t
+ O, O = 123
cumec, and
2S
t
O = 4290 cumec are read off from the curves. For O = 123 cumec, the pool
elevation of 109.8 m is read off from the O vs pool elevation curve. These values become the
initial values for the next routing period. Again, for
2S
t
O = 4290 cumec, I
1
+ I
2
= 70 + 160 =
230 cumec is added to get the right hand side of Eq. (9.8), i.e.,
2S
t
+ O = 4290 + 230 = 4520
cumec for which O and
2S
t
O values are read off and pool elevation obtained, which become
the initial values for the next routing period. Thus the process is repeated till the flood is
completely routed through the reservoir and the outflow hydrograph is obtained as shown in
Fig. 9.3 by dashed line.
Table 9.3 Reservoir routingmodified Puls method [Eq. 9.8]. (Example 9.1)
Time (hr) Inflow O
2S
t
O*
2S
t
+ O Outflow O Pool elevation
(cumec) (cumec) (cumec) (cumec) (m)
0 50 4416 4464 124 110.0
6 70 4290 4536 123 109.8
12 160 4276 4520 122 109.6
18 300 4482 4736 126 111.8
24 460 4986 5248 131 111.0
30 540 5506 5986 240 112.7
36 510 5696 6556 430 113.5
42 440 5716 6646 465 113.6
48 330 5666 6486 410 113.4
54 250 5586 6246 330 113.0
60 190 5526 6026 250 112.7
66 150 5466 5866 200 112.5
72 120 5436 5736 150 112.3
78 90 5476 5646 135 111.6
84 80 5278 5546 134 111.4
90 70 5428 130 110.8
*
2S
t
0 =
2
0
S
t
+
F
H
G
I
K
J 2O
U
V
W
U
V
W
+
+
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 270
270 HYDROLOGY
Results.
Modified
ISD method Puls method
(i) Maximum pool elevn.
reached 113.5 m* 113.6 m
(ii) Reduction in flood peak 132 cumec 75 cumec
(iii) Reservoir lag 14
1
2
hr 12 hr
*To pass the crest of the outflow hydrograph.
9.2 STREAM FLOW ROUTING
In a stream channel (river) a flood wave may be reduced in magnitude and lengthened in
travel time i.e., attenuated, by storage in the reach between two sections. The storage in the
reach may be divided into two parts-prism storage and wedge storage, Fig. 9.5, since the water
surface is not uniform during the floods. The volume that would be stored in the reach if the
flow were uniform throughout, i.e., below a line parallel to the stream bed, is called prism
storage and the volume stored between this line and the actual water surface profile due to
outflow being different from inflow into the reach is called wedge storage. During rising stages
the wedge storage volume is considerable before the outflow actually increases, while during
falling stages inflow drops more rapidly than outflow, the wedge storage becoming negative.
Negative
wedge storage
Wedge
storage
Water surface
Wedge
storage
p
rism
sto
ra
g
e
p
rism
sto
ra
g
e
p
rism
sto
ra
g
e
S
tre
a
m
b
e
d
Fig. 9.5 Storage in a stream channel during a flood wave
In the case of stream-flow routing, the solution of the storage equation is more compli-
cated, than in the case of reservoir routing, since the wedge storage is involved. While the
storage in a reach depends on both the inflow and outflow, prism storage depends on the
outflow alone and the wedge storage depends on the difference (I O). A common method of
stream flow routing is the Muskingum method (McCarthy, 1938) where the storage is ex-
pressed as a function of both inflow and outflow in the reach as
S = K [xI + (1 x) O] ...(9.9)
where K and x are called the Muskingum coefficients (since the Eq. (9.9) was first developed by
the U.S. Army Corps of Engineers in connection with the flood control schemes in the
Muskingum River Basin, Ohio), K is a storage constant having the dimension of time and x is
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 271
FLOODS ROUTING 271
a dimensionless constant for the reach of the river. In natural riverchannels x ranges from 0.1
to 0.3. The Eq. (9.9) in most flood flows approaches a straight line. Trial values of x are as-
sumed and plots of S vs. [xI + (1 x) O] are in the form of storage loops; for a particular value
of x, the plot is a straight line and the slope of the line gives K. If S is in cumec-day and I, O are
in cumec, K is in day.
After determining the values of K and x, the outflow O from the reach may be obtained
by combining and simplifying the two equations.
I I
1 2
2
+ F
H
G
I
K
J
t
O O

+ F
H
G
I
K
J
1 2
2
t = S
2
S
1
...(9.10)
same as (9.6)
and S
2
S
1
= K [x (I
2
I
1
) + (1 x) (O
2
O
1
)] ...(9.11)
(Eq. 9.11 is the same as Eq. (9.9)); for a discrete time interval the following equation may be
obtained
O
2
= C
0
I
2
+ C
1
I
1
+ C
2
O
1
...(9.12)
where C
0
=
Kx t
K Kx t

+
0 5
0 5
.
.
...(9.12 a)
C
1
=
Kx t
K Kx t
+
+
0 5
0 5
.
.
....(9.12 b)
C
2
=
K Kx t
x t

+
0 5
0 5
.
. K K
...(9.12 c)
Combining Eq. (9.12 a, b, c) gives
C
0
+ C
1
+ C
2
= 1 ...(9.12 d)
where t is the routing period. The routing period should be less than the time of travel for the
flood wave through the reach, otherwise it is possible that the wave crest may pass completely
through the reach during the routing period. Usually the routing period is taken as about 1/3
to 1/4 of the flood wave travel time through the reach (obtained from the inflow-hydrograph).
If there is a local inflow due to a tributary entering the mainstream, it should be added
to I or O accordingly as it enters the reach at the upstream or downstream end, or the local
inflow may be divided, a portion added to I and another portion added to O.
A number of methods have been developed for flood routing. The numerical method of
solution of the routing equations is tedious but has the advantage of easy checking and filling.
The Sorensens graphical method of reservoir routing has the advantage that variable time
periods can be used. Chengs graphical method is used for stream flow routing. Quite a number
of mechanical instruments, flood routing slide rules and electronic computers, etc. have been
used to facilitate computations.
Example 9.2 The inflow and outflow hydrographs for a reach of a river are given below. Deter-
mine the value of the Muskingum coefficients K and x for the reach.
Time (hr) 0 24 48 72 96 120 144 168 192 216
Inflow (cumec) 35 125 575 740 456 245 144 95 67 50
Outflow (cumec) 39 52 287 624 638 394 235 142 93 60
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 272
272 HYDROLOGY
Solution From the daily readings of the inflow and outflow hydrographs, a routing period t =
24 hr = 1 day is taken. The mean storage is determined from Eq. (9.10) and then the cumula-
tive storage S is tabulated. For trial values of x = 0.2, 0.25 and 0.3, the values of [xI + (1 x) O]
are computed in Table 9.4. Storage loops for the reach, i.e., curves of S vs. [xI + (1 x) O] for
each trial value of x are plotted as shown in Fig. 9.6. By inspection, the middle value of x = 0.25
approximates a straight line and hence this value of x is chosen. K is determined by measuring
the slope of the median straight line which is found to be 0.7 day. Hence, for the given reach of
the river, the values of the Muskingum coefficients are
x = 0.25, K = 0.7 day
Example 9.3 The inflow hydrograph readings for a stream reach are given below for which the
Muskingum coefficients of K = 36 hr and x = 0.15 apply. Route the flood through the reach and
determine the outflow hydrograph. Also determine the reduction in peak and the time of peak of
outflow.
0
100
200 300 400 500 600 700
x + (1 x) O (cumec) I
500
400
300
200
100
0
c
u
m
s
t
o
r
a
g
e
S
(
c
u
m
e
c
-
d
a
y
)
Storage
loop
x = 0.2
0
100
200 300 400 500 600 700
x + (1 x) O (cumec) I
500
400
300
200
100
0
S
(
c
u
m
e
c
-
d
a
y
)
Storage
loop
x = 0.3
0
100
200 300 400 500 600 700
x + (1 x) O, cumec I
500
400
300
200
100
0
S
(
c
u
m
e
c
-
d
a
y
)
Median
line
Dx
= 430 cumec
Dy = 300 cumec-day
Muskingum
coefficients:
k = 0.7 day, x = 0.25
approx.
St. line
m = k
x = 0.25
300 c.d
430 c
K = =
Dy
x D
= 0.7 day
Fig. 9.6 Storage loops for the reach of the river (Example 9.2)
Outflow at the beginning of the flood may be taken as the same as inflow.
Time (hr) 0 12 24 36 48 60 72 84 96 108 120
Inflow (cumec) 42 45 88 272 342 288 240 198 162 133 110
Time (hr) 132 144 156 168 180 192 204 216 228 240
Inflow (cumec) 90 79 68 61 56 54 51 48 45 42
Solution Eq. 9.12: O
2
= C
0
I
2
+ C
1
I
1
+ C
2
O
1
x = 0.15, K = 36 hr = 1.5 day; take the routing period (from the inflow hydrograph readings) as
12 hr =
1
2
day. Compute C
0
, C
1
and C
2
as follows:
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 273
FLOODS ROUTING 273
T
i
m
e
I
n
f
l
o
w
O
u
t
f
l
o
w
I

O
M
e
a
n
c
u
m
u
l
a
t
i
v
e
x

=

0
.
2
X

=

0
.
2
5
X

=

0
.
3
(
h
r
)
I
O
(
c
u
m
e
c
)
s
t
o
r
a
g
e
s
t
o
r
a
g
e
0
.
2

I
0
.
8
O
T
o
t
a
l
0
.
2
5

I
0
.
7
5

O
T
o
t
a
l
0
.
3
I
0
.
7
O
T
o
t
a
l
(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
c
u
m
e
c
-
(
c
u
m
e
c
-
(
c
u
m
e
c
)
(
c
u
m
e
c
)
(
c
u
m
e
c
)
d
a
y
)
d
a
y
)
0
3
5
3
9

2
7
3
1
.
2
3
8
.
2
8
.
7
5
2
9
.
2
5
3
8
.
0
1
0
.
5
2
7
.
3
3
7
.
8
2
4
1
2
5
5
2
7
3
3
4
3
2
2
5
4
1
.
6
6
6
.
6
3
1
.
2
5
3
9
.
0
7
0
.
2
5
3
7
.
4
3
6
.
4
7
3
.
9
4
8
5
7
5
2
8
7
2
8
8
1
8
0
2
1
2
1
1
5
2
2
9
.
6
3
4
4
.
6
1
4
3
.
7
5
2
1
5
3
5
8
.
7
5
1
7
2
.
5
2
0
0
.
9
3
7
3
.
4
7
2
7
4
0
6
2
4
1
1
6
2
0
2
4
1
4
1
4
8
4
9
9
.
2
6
4
7
.
2
1
8
5
.
0
4
6
8
6
5
3
.
0
2
2
2
.
0
4
3
6
.
8
6
5
8
.
8
9
6
4
5
6
6
3
8

1
8
2

3
3
3
8
1
9
1
.
2
5
1
0
.
4
6
0
1
.
6
1
1
4
.
0
4
7
8
5
9
2
.
0
1
3
6
.
8
4
4
6
.
6
5
8
3
.
4
1
2
0
2
4
5
3
9
4

1
4
9

1
6
5
2
1
6
4
9
3
1
5
.
2
3
6
4
.
2
6
1
.
2
5
2
9
5
.
5
3
5
6
.
7
5
7
3
.
5
2
7
5
.
8
3
4
9
.
3
1
4
4
1
4
4
2
3
5

9
1

1
2
0
9
6
2
8
.
8
1
8
8
.
0
2
1
6
.
8
3
6
.
0
1
7
6
.
3
2
1
2
.
3
4
3
.
2
1
6
4
.
5
2
0
7
.
7
1
6
8
9
5
1
4
2

4
7

6
9
2
7
1
9
.
0
1
1
3
.
6
1
3
2
.
6
2
3
.
7
5
1
0
1
.
6
4
1
2
5
.
3
9
2
8
.
5
9
9
.
4
1
2
7
.
9
1
9
2
6
7
9
3

2
6

3
7

1
0
1
3
.
4
7
4
.
4
8
7
.
8
1
6
.
7
5
6
9
.
7
8
6
.
4
5
2
0
.
1
6
5
.
1
8
5
.
2
2
1
6
5
0
6
0

1
0

1
8

2
8
1
0
4
8
.
0
5
8
.
0
1
2
.
5
4
5
.
0
5
7
.
5
1
5
.
0
4
2
.
0
5
7
.
0
T
a
b
l
e

9
.
4

D
e
t
e
r
m
i
n
a
t
i
o
n

o
f

t
h
e

M
u
s
k
i
n
g
u
m

c
o
e
f
f
i
c
i
e
n
t
s

K

a
n
d

x

f
o
r

a

r
e
a
c
h

o
f

t
h
e

r
i
v
e
r
.

(
E
x
a
m
p
l
e

9
.
2
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 274
274 HYDROLOGY
C
0
=
Kx t
K Kx t

+
0 5
0 5
.
.
=
15 0 15 0 5
15 15 0 15 0 5
1
2
1
2
. . .
. . . .

+
=
0 025
1525
.
.
= 0.02
C
1
=
Kx t
K Kx t
+
+
0 5
0 5
.
.
=
15 0 15 0 5
1525
1
2
. . .
.
+
= 0.31
C
2
=
K Kx t
x t

+
0 5
0 5
.
. K K
=
15 15 0 15 0 5
1525
1
2
. . . .
.

= 0.67
Check: C
0
+ C
1
+ C
2
= 0.02 + 0.31 + 0.67 = 1
O
2
= 0.02 I
2
+ 0.31 I
1
+ 0.67 O
1
In Table 9.5, I
1
, I
2
are known from the inflow hydrograph, and O
1
is taken as I
1
at the
beginning of the flood since the flow is almost steady.
Table 9.5 Stream flow routingMuskingum method
[Eq. 9.12]. (Example 9.3)
Time Inflow 0.02 I
2
0.31 I
1
0.67 O
1
Outflow
(hr) I (cumec) (cumec) (cumec) O
(cumec) (cumec)
0 42 42*
12 45 0.90 13.0 28.2 42.1
24 88 1.76 14.0 28.3 44.0
36 272 5.44 27.3 29.5 62.2
48 342 6.84 84.3 41.7 132.8
60 288 5.76 106.0 89.0 200.7
72 240 4.80 89.2 139.0 233.0
84 198 3.96 74.4 156.0 234.0
96 162 3.24 61.4 157.0 221.6
108 133 2.66 50.2 148.2 201.0
120 110 2.20 41.2 134.5 178.9
132 90 1.80 34.1 119.8 155.7
144 79 1.58 27.9 104.0 133.5
156 68 1.36 24.4 89.5 115.3
163 61 1.22 21.1 77.4 99.7
180 56 1.12 18.9 66.8 86.8
192 54 1.08 17.4 58.2 76.7
204 51 1.02 16.7 51.4 69.1
216 48 1.00 15.8 46.3 63.1
228 45 0.90 14.8 42.3 58.0
240 42 0.84 13.9 38.9 53.6
*O
1
is assumed equal to I
1
= 42 cumec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 275
FLOODS ROUTING 275
O
2
= 0.02 45 + 0.31 42 + 0.67 42 = 42.06 cumec
This value of O
2
becomes O
1
for the next routing period and the process is repeated till
the flood is completely routed through the reach. The resulting outflow hydrograph is plotted
as shown in Fig. 9.7. The reduction in peak is 108 cumec and the lag time is 36 hr, i.e., the peak
outflow is after 84 hr (= 3
1
2
days) after the commencement of the flood through the reach.
0 24 48 72 96 120 144 168 192 216 240
Time t (hr)
400
350
300
250
200
150
100
50
0
I
n
f
l
o
w
o
r
o
u
t
f
l
o
w
Q
(
c
u
m
e
c
)
12 hr routing period
Lag
36 hr
To
stor-
age
F
r
o
m
s
t
o
r
a
g
e
Equal
areas
Inflow hydrograph
Peak out-flow after 84 hr
108 cumec = Reduction in peak
Outflow hydrograph
k = 36 hr = 1 day
x = 0.15
1
2
84 hr
Fig. 9.7 Streamflow routing by Muskingum method (Example 9.3)
OUZ X
I Match the items in A with the items in B
A B
(i) Flood routing (a) Muskingum method
(ii) ISD method (b) f (I 0)
(iii) Modified Puls method (c) f(0)
(iv) Stream-flow routing (d) Sorensens graphical method
(v) Wedge storage (e) Chengs graphical method
(vi) Prism storage (f)
2S
t
0 curves
(vii) Reservoir routing (g) S
0
2
t
curves
(viii) Streamflow routing (h) Outflow hydrograph
II Say true or false, if false, give the correct statement:
(i) In flood routing through reservoir
Given are:
(a) Pool elevation vs. storage (b) Pool elevation vs. outflow (discharge)
(c) Flood hydrograph of inflow
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 276
276 HYDROLOGY
Required to find at any time after the commencement of flood
(a) Reservoir stage (pool elevation) (b) Storage volume
(c) Outflow (d) Reduction in flood peak
(e) Maximum pool elevation reached (f) Reservoir lag
(ii) The outflow consists of discharge over the spillway only
(iii) The routing period should be greater than the time of travel of the flood wave through the
reach.
(iv) The routing period should be sufficiently short such that the hydrograph during this interval
can be assumed as a straight line.
(v) Reservoir routing by modified Puls method is simpler than I.S.D. method.
(vi) Stream flow routing is more complicated than reservoir routing since the prism storage is
involved.
(vii) While storage is simply a function of discharge in reservoir routing, it (storage) is a function
of both inflow and outflow in steamflow routing since wedge storage is involved.
(viii) Inflow is a parameter in the storage equation of streamflow routing to adequately represent
the prism storage.
(ix) The storage in a reach consists of prism storage and wedge storage, the former is due to the
nonuniformity of water surface while the latter is beneath a line parallel to the stream bed.
(x) The wedge storage volume becomes negative during rising stages.
(xi) The wedge storage depends on the outflow alone while the prism storage depends on the
difference of inflow and outflow.
(xii) The routing period is taken as about 1/3 to 1/4 of the flood wave travel time through the reach
and is obtained from the flood hydrograph of inflow.
(xiii) Variable time periods can be used in the Sorensens graphical method of reservoir routing.
(xiv) Chengs graphical method is used for reservoir routing.
(xv) Local inflow due to a tributary poses a problem in streamflow routing.
(xvi) Though mechanical and electronic devices have been developed for flood routing computa-
tions, the numerical methods have the advantage of easy checking and filling.
(false: ii, iii, vi, viii, ix, x, xi, xiv)
III Choose the correct statement/s in the following:
1 Given a hdyrograph of inflow into the reservoir, flood routing is the process of determining.
(i) reservoir pool elevation (ii) resorvoir storage
(iii) hydrograph of outflow from the reservoir
(iv) discharge over the spillway and through sluice ways
(v) exclusion of silt-charge from the reservoir
(vi) head available for the power plant (vii) all the above items
2 Wedge storage in a channel reach is a function of
(i) inflow into the reach (ii) ouflow from the reach
(iii) difference between the inflow and outflow
(iv) the routing period (v) prism storage
(vi) local inflow (from a tributary joining at mid-reach)
(vii) all the above factors (1 i, ii, iii; 2 iii, vi)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 277
FLOODS ROUTING 277
OUE8TON8
1 (a) Define flood routing. What are the usual assumptions made in routing a flood in a reservoir?
(b) Explain clearly the I.S.D. curves method of reservoir flood routing. What are the factors to be
considered in choosing the routing period?
2 (a) Take any two flood routing methods you know of and show that they are only solutions of the
continuity equation I 0 =
dS
dt
.
(b) A retarding basin has storage and discharge characteristics as given below. The dam has an
ungated sluice 1.5 m dia with its centre at elevation 157.5 m and a spillway at crest elevation
226.5 m. Discharge given below for pool elevations above 226.5 m include both sluice and
spillway discharge. The inflow hydrograph is also given below.
Route the flood through the reservoir
(i) by ISD method
(ii) by the modified Puls method
Determine the maximum pool elevation reached, the reduction in flood peak and the reservoir
lag. Pool elevation at commencement = 157.8 m (for which the discharge = 5.95 cumec).
(i) Pool Elevation vs. Storage and Discharge data:
Pool Elvn. Storage (ham) Discharge
(m) (= 10
4
m
3
) (cumec)
157.5 0.085 3.9
159 0.368 17.3
162 1.33 29.8
168 7.6 45.5
174 21.2 57.0
180 43.8 66.7
186 80.4 75.0
192 136.0 82.8
198 208 89.5
204 297 96
210 400 102
216 520 108
222 655 114
225 728 116
226.5 764 117
227.4 787 119
228.0 805 289
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 278
278 HYDROLOGY
(ii) Inflow hydrograph data
Time Inflow Time Inflow
(hr) (cumec) (hr) (cumec)
0 15 36 141
6 57 42 93
12 159 48 60
18 258 54 33
24 246 60 18
30 198
(Hint Take routing period t = 6 hr = 1/4 day)
Draw the curves:
(i) Pool elevation vs. discharge (outflow)
(ii) Discharge (outflow) in comec vs. S
Ot
2
in cumec
1
4
day, for ISD method of routing.
(iii) Discharge (outflow) in cumec vs.
2S
t
O in cumec, for modified Puls method of routing.
3 (a) How does stream flow routing differ from reservoir flood routing?
(b) The inflow hydrograph readings for a stream reach are given below for which the Muskingum
coefficients of K = 30 hr and x = 0.2 apply. Route the flood through the reach and determine
the reduction in peak and the time of peak of outflow. Outflow at the beginning of the flood
may be taken as the same as inflow.
Time Inflow Time Inflow
(hr) (cumec) (hr) (cumec)
0 15 132 32
12 16 144 28
24 31 156 24
36 96 168 22
48 121 180 20
60 102 192 19
72 85 204 18
84 70 216 17
96 57 228 16
108 47 240 15
120 39
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD9-1.PM5 279
FLOODS ROUTING 279
4 (a) Show that storage in a stream reach can be expressed in terms of inflow and outflow in the
form:
S = K [xI + (1 x) 0]
(b) The inflow and outflow hydrographs for a reach of a river are given below. Determine the
best values of the Muskingum coefficients K and x for the reach.
Time Inflow Outflow
(hr) (cumec) (cumec)
0 20 20
12 191 30
24 249 120
36 164 176
48 110 164
60 82 135
72 62 116
84 48 90
96 32 68
108 28 52
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 10
STORAGE, PONDAGE AND FLOW
DURATION CURVES
280
10.1 RESERVOIR MASS CURVE AND STORAGE
During high flows, water flowing in a river has to be stored so that a uniform supply of water
can be assured, for water resources utilisation like irrigation, water supply, power generation,
etc. during periods of low flows of the river.
A mass diagram is a graphical representation of cumulative inflow into the reservoir
versus time which may be monthly or yearly. A mass curve is shown in Fig. 10.1 for a 2-year
period. The slope of the mass curve at any point is a measure of the inflow rate at that time.
Required rates of draw off from the reservoir are marked by drawing tangents, having slopes
equal to the demand rates, at the highest points of the mass curve. The maximum departure
between the demand line and the mass curve represents the storage capacity of the reservoir
required to meet the demand. A demand line must intersect the mass curve when extended
forward, otherwise the reservoir is not going to refill. The vertical distance between the suc-
cessive tangents represent the water wasted over the spillway. The salient features in the
mass curve of flow in Fig. 10.1 are:
a-b: inflow rate exceeds the demand rate of x cumec and reservoir is overflowing
b: inflow rate equals demand rate and the reservoir is just full
b-c: inflow rate is less than the demand rate and the water is drawn from storage
c: inflow rate equals demand rate and S
1
is the draw off from the reservoir (Mm
3
)
c-d: inflow rate exceeds demand rate and the reservoir is filling
d: reservoir is full again
d-e: same as a-b
e: similar to b
e-f: similar to b-c
f: inflow rate equals demand rate and S
2
is the draw off from the reservoir
f-g: similar to c-d
To meet the demand rate of x cumec the departure S
2
> S
1
; hence, the storage capacity
of the reservoir is S
2
Mm
3
. If the storage capacity of the reservoir, from economic considera-
tions, is kept as S
1
Mm
3
, the demand rate of x cumec can not be maintained during the time
e-f and it can be at a lesser rate of y cumec (y < x).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 281
STORAGE, PONDAGE AND FLOW DURATION CURVES 281
Res.
empty
f
For the demand rate
of x cumec, S > S
2 1
Storage capacity
of reservoir = S Mm
2
3
Water wasted
over spillway
x
c
u
m
e
c
Water drawn
from storage
e
d
Reservoir
fills again
x
c
u
m
e
c
Reservoir
full
Reg.
empty
Water drawn
from storage
Mass curve
of inflow
b
Draw off
rate
S
l
o
p
e
=
x
-
c
u
m
e
c
=
y
-
c
u
m
e
c
1 year
Cum.
storage
per year
Inflow rate into reservoir
Draw off rate
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
,
(
M
.
m
o
r
h
a
-
m
)
3
0
a
A S O N D J F M A M J J A S O N D J F M A M J J A S
1970 1971 1972
Time (months & year)
y
c
u
m
e
c
S
1
g
c
S
2
S
1
s
1
S
2
Fig. 10.1 Storage capacity of reservoir from mass curve
The use of mass curve is to determine:
(i) the storage capacity of the reservoir required to meet a particular withdrawal rate.
(ii) the possible rate of withdrawal from a reservoir of specified storage capacity.
The observed inflow rates have to be adjusted for the monthly evaporation from the
reservoir surface, precipitation, seepage through the dam, inflow from adjacent basins, re-
quired releases for downstream users, sediment inflow, etc. while calculating the storage ca-
pacity of the reservoir.
The average flow figures for the site of a proposed dam are collected for about 10 years.
From this record the flow figures for the driest year are used for drawing the mass flow curve.
Graphical analysis is enough for preliminary studies. Final studies are made by tabular com-
putation. If tangents are drawn to the crest and trough of the mass curve such that the depar-
ture of the lines represents the specified reservoir capacity, the slope of the tangent at the
crest gives the continuous flow that can be maintained with the available storage capacity.
From this the greatest continuous power output for the available fall at the site for a given
plant efficiency and load factor can be determined.
From the daily flow data a hydrograph or a bar graph is drawn for the maximum flood
during the period of 10 years and the spillway capacity to pass this flood with the available
storage capacity is determined. Thus, the power and the flood control potentialities of the site
are investigated. Also see Appendix-C.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 282
282 HYDROLOGY
The mass curve of water utilisation need not be a straight line. The dashed curve in
Fig. 10.2 shows the cumulative requirements of water use in different months as compared
with monthly cumulatively inflow. The maximum draft in the reservoir (i.e., maximum depar-
ture of the water use and inflow curves) occurs by the end of April. The reservoir again be-
comes full by the end of September when the two curves intersect.
Max draft
in May
Reservoir full
by end of Sept.
Mass curve of water
utilisation
Reservoir
full on
Dec. 1
Mass curve of
monthly inflow
1
2
700
600
500
400
300
200
100
0
D J F M A M J J A S O N D
Time (months)
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
(
M
.
m
o
r
h
a
m
)
3
Fig. 10.2 Mass curves of water utilisation and monthly inflow
Example 10.1 The following is a record of the mean monthly discharges of a river in a dry
year. The available fall is 80 m. Determine
(i) the minimum capacity of a reservoir if the entire annual inflow is to be drawn off at
a uniform rate (with no flow going into waste over the spillway).
(ii) the amount of water which must be initially stored to maintain the uniform draw off.
(iii) the uniform power output assuming a plant efficiency of 70%.
(iv) If the amount of water initially stored is 125 Mm
3
, the maximum possible draw off
rate and the amount of water wasted over the spillway (assuming the same reservoir capacity
determined in (i) above.
(v) if the largest reservoir that can be economically constructed is of capacity 125 Mm
3
,
the maximum possible output and the amount of water wasted over the spillway.
(vi) the capacity of the reservoir to produce 22.5 megawatts continuously throughout the
year.
Month Mean flow Month Mean flow
(cumec) (cumec)
Jan. 29.7 July 68.0
Feb. 75.3 Aug. 50.2
March 66.8 Sept. 74.5
April 57.2 Oct. 66.8
May 23.2 Nov. 40.5
June 26.3 Dec. 26.3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 283
STORAGE, PONDAGE AND FLOW DURATION CURVES 283
Solution Take each month as 30 days for convenience; 1 month = 30 days 86400 sec = 2.592
10
6
sec. Inflow volume in each month = monthly discharge 2.592 Mm
3
; and monthly inflow
and cumulative inflow are tabulated in Table 10.1.
Table 10.1 Cumulative inflow into reservoir
Month Mean flow Inflow cumulative Month Mean flow Inflow cumulative
(cumec) volume inflow (cumec) volume inflow
(Mm
3
) (Mm
3
) (Mm
3
) (Mm
3
)
Jan. 29.7 77 77 July 68.0 176 897
Feb. 75.3 195 272 Aug. 50.2 130 1027
Mar. 66.8 173 445 Sept. 74.5 193 1220
April 57.2 148 593 Oct. 66.8 173 1393
May 23.2 60 653 Nov. 40.5 105 1498
June 26.3 68 721 Dec. 26.3 68 1566
Plot the mass curve of flow as cumulative inflow vs month as shown in Fig. 10.3.
(i) Join OA by a straight line; the slope of OA, i.e., 1566 Mm
3
/yr or (1566 10
6
)m
3
/(365
86400) sec = 49.7 cumec is the uniform draw off throughout the year with no spill over the
spillway. Draw BC || OA, GH || OA, B, G being the crests of the mass curve; EH = FG
Minimum capacity of reservoir = DE + EH = 150 + 20 = 170 Mm
3
Note If the capacity is less than this, some water will be wasted and if it is more than this, the
reservoir will never get filled up.
(ii) Amount of water to be initially stored for the uniform draw off of 49.7 cumec = DE
= 150 Mm
3
(iii) Continuous uniform power output in kW, P =

w
g QH
1000
0

where
w
= mass density of water, 1000 kg/m
3
Q = discharge into turbines
H = head on turbines ( available fall)

0
= overall or plant efficiency
P =
1000 49 7 80
1000
0 70

9.81 .
.
= 27400 kW
or = 27.4 MW
(iv) If the amount of water initially stored is only 125 M.m
3
, measure DI = 125 M.m
3
,
join BI and produce to J. The slope of the line BJ is the maximum possible draw off rate. Let
the line BJ intersect the ordinate through O (i.e., the cumulative inflow axis) at K. The vertical
intercept KJ = 1430 Mm
3
and the slope of this line = 1430 Mm
3
/yr = 45.4 cumec which is the
maximum possible draw off rate.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 284
284 HYDROLOGY
Spilling
(during MN,RU)
Spillage = PM, RS
S
P
G
N
C
M
L
T
F
H
V
U
(170)
(150)E
I
125
B
K
D
A (1566
M.m )
3
1
0
0
z
(1287 Mm )
3
Q
J J
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
,
M
.
m
3
K
J
=
1
4
3
0
M
.
m

3
1 - year base
Line - slope = M.m /yr cumec MW
3
OA // BC // GH = 1566 = 49.7 27.4
KJ // HL // GT = 1430 = 45.4 25.0
BV // OQ = 1287 = 40.8 22.5
J kJ = 1430 M.m
3
1600
1500
1400
1300
1200
1100
1000
900
800
700
600
500
400
300
200
100
0
J F M A M J J A S O N D
Time (months)
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
(
M
m
3
)
49.7 cumec
45.4 cumec
40.8 cumec
Draw off rates
A
Q
R
1566 Mm
3
1430 Mm
3
1287 Mm
3
O
1 year
Time
b. Key for slopes (Q)
Cumulative
storage
C. Mass curve analysis
Mass curve of
reservoir inflow
Reservoir full
B
Draw off rates
a. key for mass curve
170 M.m
3
150 M.m
3
20 M.m
3
D
H
z
E
125 M.m
3
100 M.m
3 D
C
N
G
F
P
40 Mm
3
M
R
V
T
85 Mm
3
Spillage
A
Q
1560
Mm
3
1287
Mm
3
Q P
K
L j
O
I
R
Fig. 10.3 Mass curve studies in reservoir design (Example 10.1)
To maintain the same reservoir capacity of 170 M.m
3
, draw the straight line HL || KJ
intersecting the mass curve of flow at M and N. Draw the straight line GT || HL. The vertical
intercept PM gives the amount of water wasted over the spillway (during the time period MN)
which is 40 Mm
3
.
(v) If the reservoir capacity is limited to 125 M.m
3
from economic considerations, the
line KJ intersects the mass curve of flow at R. Let the vertical at R meet the line GT (GT || KJ)
at S. In this case the amount of water wasted over the spillway = RS = 85 Mm
3
. The maximum
possible output in this case for a uniform draw off rate of 45.4 cumec is
P = 27.4
45 4
49 7
.
.
= 25 MW
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 285
STORAGE, PONDAGE AND FLOW DURATION CURVES 285
(vi) For a continuous power output of 22.5 MW the uniform draw off rate can be deter-
mined from the equation
22500 kW =
1000 9 81 80
1000
. Q
0.70
Q = 40.8 cumec
which can also be calculated as 49.7
22 5
27 4
.
.
= 40.8 cumec = 40.8 (365 86400 sec) = 1287 Mm
3
/yr.
On the 1-year base, draw the ordinate at the end of December = 1287 M.m
3
and join the line
OQ (dashed line). The slope of this line gives the required draw off rate (40.8 cumec) to produce
a uniform power output of 22.5 mW. Through B and D, i.e., the crest and the trough draw
tangents parallel to the dashed line OQ (BV || OQ). The vertical intercept between the two
tangents DZ gives the required capacity of the reservoir as 100 Mm
3
.
10.2 FLOW DURATION CURVES
Flow duration curves show the percentage of time that certain values of discharge weekly,
monthly or yearly were equalled or exceeded in the available number of years of record. The
selection of the time interval depends on the purpose of the study. As the time interval in-
creases the range of the curve decreases, Fig. 10.4. While daily flow rates of small storms are
useful for the pondage studies in a runoff river power development plant, monthly flow rates
for a number of years are useful in power development plants from a large storage reservoir.
The flow duration curve is actually a river discharge frequency curve and longer the period of
record, more accurate is the indication of the long term yield of a stream. A flat curve indicates
a river with a few floods with large ground water contribution, while a steep curve indicates
frequent floods and dry periods with little ground water contribution. Since the area under the
curve represents the volume of flow, the storage will affect the flow duration curve as shown
by the dashed line in Fig. 10.5; i.e., reducing the extreme flows and increasing the very low
flows.
Mean daily flows
Mean monthly flows
Mean annual flows
F
l
o
w
r
a
t
e
Q
(
c
u
m
e
c
)
600
500
400
300
200
100
0
0 20 40 60 80 100
% time Q
=
>
Fig. 10.4 Flow duration curveseffect of observation period
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 286
286 HYDROLOGY
Flow duration curve
(monthly flows)
Storage effect on
flow duration curve
Flow duration curve
(Weekly flows)
Power duration curve
335
272
600
500
400
300
200
100
0
0 10 20 30 40 50 60 70 80 75 90 100
0
50
100
150
200
250
300
M
e
a
n
m
o
n
t
h
l
y
f
l
o
w
Q
(
c
u
m
e
c
)
P
o
w
e
r
P
,
M
W
% time > Q or P values indicated
157
Fig. 10.5 Flow duration and power duration curves (Example 10.2)
Since drought is often defined in terms of a fixed period of time with less than some
minimum amount of rainfall, the flow duration curves are useful for determining the duration
of floods or droughts, the latter being of prime importance in the semi-arid regions. Duration
curves for long periods of runoff are also useful for deciding the flow rates to be used for
particular purposes, say, for power development.
The usual procedure is to arrange the flow values (or range of flow values weekly, monthly
or yearly) in the available period of record (usually a minimum of 10 years) in the ascending
order of magnitude and the number of occurrences of each flow value (or range of flow values).
From this the number of times and the percent of time each flow value (or range of flow values)
has been equalled or exceeded in the period of record may be obtained. The duration curve is
constructed by plotting each flow value (or lower value of the class interval) against the per-
cent of time it has been equalled or exceeded. The power duration curve is the same as the flow
duration curve, the discharge scale being converted to power units corresponding to the avail-
able head (assuming the head constant) since
Power in kW, P =

w
g QH
1000
0

or, P = a constant Q
where Q is the flow value being equalled or exceeded during a certain percent of time.
Flow duration curves are useful in the studies relating to navigation problems, water
power, water supply, irrigation and sanitation.
Example 10.2 The following data are obtained from the records of the mean monthly flows of
a river for 10 years. The head available at the site of the power plant is 60 m and the plant
efficiency is 80%.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 287
STORAGE, PONDAGE AND FLOW DURATION CURVES 287

Mean monthly flow range No. of occurrences


(cumec) (in 10-yr period)
100-149 3
150-199 4
200-249 16
250-299 21
300-349 24
350-399 21
400-499 20
450-499 9
500-549 2
(a) Plot
(i) The flow duration curve (ii) The power duration curve
(b) Determine the mean monthly flow that can be expected and the average power that
can be developed.
(c) Indicate the effect of storage on the flow duration curve obtained.
(d) What would be the trend of the curve if the mean weekly flow data are used instead of
monthly flows.
Solution (a) The mean monthly flow ranges are arranged in the ascending order as shown in
Table 10.2. The number of times that each mean monthly flow range (class interval, C.I.) has
been equalled or exceeded (m) is worked out as cumulative number of occurrences starting
from the bottom of the column of number of occurrences, since the C.I. of the monthly flows,
are arranged in the ascending order of magnitude. It should be noted that the flow values are
arranged in the ascending order of magnitude in the flow duration analysis, since the minimum
Table 10.2 Flow duration analysis of mean monthly flow data of a
river in a 10 yr period (Example 10.2)
Mean monthly No. of No. of time Percent of time Monthly power
flow occurrences equalled or lower value of P = 0.472 Q
class interval (in 10-yr exceeded CI equalled or (MW)
C.I. period) (m) exceeded Q = lower value of
(cumec) =
m
n
100% C.I.
100-149 3 120 100 47.2
150-199 4 117 97.5 70.8
200-249 16 113 94.2 94.4
250-299 21 97 80.8 118
300-349 24 76 63.3 142
350-399 21 52 43.3 165
400-499 20 31 25.8 189
450-499 9 + 11 9.2 212
500-549 2 + 2 1.7 236
Total n = 120
Note: For droughtduration studies, m = No. of times equal to or less than the flow value and
has to be worked from the top; percent of time the flow value is
m
n
100. In this example, m = 3, 7, 23,
44, ... and % of time Q are 2.5, 5.83, 19.2, 36.7. ...., respectively (from top).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 288
288 HYDROLOGY
continuous flow that can be expected almost throughout the year (i.e., for a major percent of
time) is required particularly in drought duration and power duration studies, while in flood
flow analysis the CI may be arranged in the descending order of magnitude and m is worked
out from the top as cumulative number of occurrences since the high flows are of interest. The
percent of time that each CI is equalled or exceeded is worked out as the percent of the total
number of occurrences (m) of the particular CI out of the 120 (= 10 yr 12 = n) mean monthly
flow values, i.e., =
m
n
100. The monthly power developed in megawatts,
P =
gQH
1000

0
=
9.81
0.80

F
H
G
I
K
J
60
1000

Q
P = 0.472 Q
where Q is the lower value of the CI Thus, for each value of Q, P can be calculated.
(i) The flow duration curve is obtained by plotting Q vs. percent of time, Fig. 10.5,
(Q = lower value of the CI).
(ii) The power duration curve is obtained by plotting P vs. percent of time, Fig. 10.5.
(b) The mean monthly flow that can be expected is the flow that is available for 50% of
the time i.e., 357.5 cumec from the flow duration curve drawn. The average power that can be
developed i.e., from the flow available for 50% of the time, is 167 MW, from the power duration
curve drawn.
(c) The effect of storage is to raise the flow duration curve on the dry weather portion
and lower it on the high flow portion and thus tends to equalise the flow at different times of
the year, as indicated in Fig. 10.5.
(d) If the mean weekly flow data are used instead of the monthly flow data, the flow
duration curve lies below the curve obtained from monthly flows for about 75% of the time
towards the drier part of the year and above it for the rest of the year as indicated in Fig. 10.5.
In fact the flow duration curve obtained from daily flow data gives the details more
accurately (particularly near the ends) than the curves obtained from weekly or monthly flow
data but the latter provide smooth curves because of their averaged out values. What duration
is to be used depends upon the purpose for which the flow duration curve is intended.
10.3 PONDAGE
While storage refers to large reservoirs to take care of monthly or seasonal fluctuations in the
river flow, pondage usually refers to the small storage at the back of a weir, in run-of-river
plants, for temporarily storing water during non-working hours, idle days and low load peri-
ods for use during hours of peak load demand. Run-of-river plants are feasible for streams
which have a minimum dry weather flow or receive flow as regulated by any storage reservoir
upstream.
Pondage factor is the ratio of the total inflow hours in a week to the total number of
hours of working of the power plant in that week. For example, assuming constant stream
flow, if a power plant operates for 6 days in a week at 8 hours per day, then the pondage factor
would be
7 24
6 8

= 3.5, and if the plant works only for 5 days in a week, the pondage factor
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 289
STORAGE, PONDAGE AND FLOW DURATION CURVES 289
would be
7 24
5 8

= 4.2 and the pondage required in the latter case would be


48 16
24
+
daily
flow volume =
8
3
of daily flow-volume.Thus the pondage factor serves as a rough guide of the
amount of pondage required when the stream flow is constant and the plant works only for a
part of the period. Pondage is needed to cover the following four aspects:
(i) To store the idle day flow.
(ii) For use during hours of peak load.
(iii) To balance the fluctuations in the stream flow.
(iv) To compensate for wastage (due to leakage) and spillage.
Example 10.3 The available flow for 97% of the time (i.e., in a year) in a river is 30 cumec. A
run-of-river plant is proposed on this river to operate for 6 days in a week round the clock. The
plant supplies power to a variable load whose variation is given below:
Period (hr) 06 612 1218 1824
Load during period
24 hr average load -
ratio 0.6 1.4 1.5 0.5
The other relevant data are given below:
Head at full pond level = 16 m
Maximum allowable fluctuation of pond level = 1 m
Plant efficiency = 80%
Pondage to cover inflow fluctuations = 20% of average daily flow
Pondage to cover wastage and spillage = 10%
Determine:
(i) the average load that can be developed
(ii) daily load factor
(iii) plant capacity
(iv) weekly energy output
(v) pondage required and the surface area of the pond for satisfactory operation
Solution (i) 7 days flow has to be used in 6 days
Average flow available for power development
Q = 30
7
6
= 35 cumec
Since maximum allowable fluctuation of pond level is 1 m, average head
H =
16 15
2
+
= 15.5 m
The average load that can be developed
P =
gQH
1000

0
=
9.81 35 15.5
1000

0.8 = 4.27 MW
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 290
290 HYDROLOGY
(ii) Daily load factor =
average load
peak load
=
1
1.5
= 0.67
(iii) Plant capacity = 4.27 1.5 = 6.4 MW
(iv) Weekly energy output = Average load in kW No. of working hours
= (4.27 1000)(6 24) = 6.15 10
5
kWh
It should be noted that the installed capacity has to be equal to the peak load and the
number of units (kWh) generated will be governed by the average load.
(v) Pondage required
(a) to store the idle days flow = 30 86400 = 2.592 10
6
m
3
, or 2.592 Mm
3
(b) to store the excess flow during low loads to meet the peak load demand. Since power
developed is proportional to discharge (assuming constant average head of 15.5 m), flow re-
quired during peak load periods of 6.00 to 12.00 hr is (1.4 1) 35 cumec and from 12.00 to 18.00
hr is (1.5 1) 35 cumec.
pondage to meet peak load demand
= (0.4 + 0.5) 35 cumec for 6 hr
= (0.9 35)(6 60 60)
= 6.81 10
5
m
3
, or 0.681 Mm
3
(c) pondage to cover inflow fluctuations
= (0.20 30) 86400
= 5.18 10
5
m
3
, or 0.518 Mm
3
Total of (a), (b) and (c) = 3.791 Mm
3
Add 10% for wastage and spillage = 0.379 Mm
3
Total pondage required = 4.170 Mm
3
Since the maximum fluctuation of pond level is 1 m
the surface area of pond = 4.170 10
6
m
2
or 4.17 km
2
, or 417 ha
Example 10.4 A run-of-river hydroelectric plant with an effective head of 22 m and
plant efficiency of 80% supplies power to a variable load as given below:
Time (hr) Load (1000 kW) Time (hr) Load (1000 kW)
MN 0-2 11.4 12-14 44.2
2-4 5.6 14-16 44.4
4-6 25.6 16-18 74.2
6-8 53.2 18-20 37.8
8-10 44.8 20-22 30.0
N 10-12 39.4 22-24 18.0
Draw the load curve and determine:
(i) the minimum average daily flow to supply the indicated load.
(ii) pondage required to produce the necessary power at the peak.
(iii) the plant load factor.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 291
STORAGE, PONDAGE AND FLOW DURATION CURVES 291
Solution (i) The load curve is shown in Fig. 10.6.
35.72 (1000) kw
Ave. load
Time (hr)
0 2 4 6 8 10 12 14 16 18 20 22 24
Load factor =
35.72
74.2
= 0.482
or 48.2%
Peak load
74.2 (1000) kW
80
70
60
50
40
30
20
10
L
o
a
d
(
1
0
0
0
k
W
)
0
Fig. 10.6 Daily load curve (Example 10.4)
Total of loads at 2 hr intervals = 428.6 kW
Average load =
428.6 1000 kW 2hr
24 hr

= 35.72 1000 kW
Flow (Q) required to develop the average load
1000 22
1000
9.81 Q
0.8 = 35.72 1000
Q = 207 cumec
(ii) Flow required to produce the required load demand
Q =
207
3572 .
Load in 1000 kW
Q = 5.8 Load in 1000 kW
To determine the pondage capacity the following table is prepared:
Time Load Required Deviation from the average
(hr) (1000 kW) flow flow of 207 cumec
P (cumec) Deficiency Excess
5.8 P (cumec) (cumec)
MN: 0-2 11.4 66.10 140.90
2-4 5.6 32.46 174.54
4-6 25.6 148.40 58.60
6-8 53.2 308.20 101.20
8-10 44.8 260.00 53.00
N: 10-12 39.4 228.50 21.50
12-14 44.2 256.00 49.00
14-16 44.4 257.40 50.40
(Contd.)...page 292
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 292
292 HYDROLOGY
16-18 74.2 430.00 223.00
18-20 37.8 219.40 12.40
20-22 30.0 174.00 33.00
22-24 18.0 104.30 102.70
Total: 428.6 510.50 509.74
From the above table
Total deficiency = total excess = 510 cumec
Pondage capacity required = 510 cumec for 2 hr
= 510 (2 60 60) = 3.67 Mm
3
(iii) Plant Load factor =
average load
peak load
L.F. =
3572
74 20
.
.
= 0.482 or 48.2%.
OUZ X
I Choose the correct statement/s in the following:
1 From a reservoir mass curve the following information may be obtained:
(i) the storage capacity required for a uniform discharge and power output.
(ii) the maximum discharge possible and power output for a specified storage capacity.
(iii) the month when the reservoir is empty or just fall.
(iv) the months during which water is overflowing over the spillway.
(v) the reservoir pool elevation at any time.
(vi) all the above.
2 A flow duration curve indicates
(i) the stream flow available for different percent of time
(ii) the firm power (iii) the duration of floods or droughts
(iv) the effect of storage (v) the power available for different percent of time
(vi) all the above times.
3 Pondage is required across a river
(i) which becomes dry in summer
(ii) which gets occasional releases from an upstream reservoir
(iii) which has a sustained dry weather flow
(iv) to take care of seasonal fluctuations of streamflow
(v) to store water during off-hours, idle day and low load periods, for use during hours of peak load
(vi) to compensate for the losses due to evaporation, leakage and spillage
(vii) for all the above cases. (1. vi; 2. vi; 3. iii, iv, v, vi)
II Match the items in A with items in B
A B
(i) Storage (a) 97% of time on power-duration curve
(ii) Pondage (b) Arid region
(iii) Minimum hydrorate (c) Run-of-river plant
(iv) Drought-duration (d) Reservoir mass curve
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 293
STORAGE, PONDAGE AND FLOW DURATION CURVES 293
III Say true or false; if false, give the correct statement:
(i) A mass curve is a graphical representation of cumulative inflow into the reservoir versus
time.
(ii) The vertical distance between the successive tangents to the mass curve peaks (the slopes of
the tangents = demand rates) represents the storage capacity of the reservoir.
(iii) The slope of the mass curve at any point gives the inflow rate at that time into the reservoir.
(iv) The draw-off rates are marked by drawing tangents at the peaks, having slopes equal to the
demand rates.
(v) The maximum departure between the demand line and the mass curve gives the water wasted
over the spillway.
(vi) A demand line must intersect the mass curve when extended forward, otherwise the reser-
voir is not going to refill.
(vii) The maximum departure of the mass curve of water use and mass curve of inflow indicates
the month of maximum draft in the reservoir.
(viii) The weekly flow duration curve lies above that of the monthly flow for about 75% of the time
(towards the drier part of the year) and below it for the rest of the year.
(ix) Though the daily flow duration curve gives the details more accurately (particularly near the
ends), the weekly or monthly flow duration curves plot smooth curves (because of their aver-
aged out values).
(x) Larger the period of record, more accurate and flatter is the flow duration curve.
(xi) The effect of storage is to lower the flow duration curve on the dry weather portion and raise
it on the high flow portion, thus depicting marked variation in the flow at different times of
the year.
(xii) The pondage factor for a constant river discharge into a pond with 8-hour plant operation per
day for 6 days in a weak is 3.5, neglecting Sunday (idle-day) and the pondage required is 5/3
of the daily-flow volume.
(xiii) Run-of-river plants are feasible for streams, which do not have a sustained dry weather flow
or receive flow releases occasionally as regulated by an upstream reservoir.
(xiv) The flow-duration curves are useful for drought-duration studies particularly in semi-arid
regions. (false: ii, v, vii, x, xi, xii)
OUE8TON8
1 (a) Sketch a mass curve of run-off and explain how it is helpful in determining:
(a) the storage required to satisfy a given constant demand.
(b) the safe yield available from a given storage.
(b) The estimated monthly flow in a river is as follows:
Month Flow Month Flow
(Mm
3
) (Mm
3
)
Jan. 7.6 July 10.7
Feb. 19.5 Aug. 13.0
March 17.3 Sept. 19.2
April 10.5 Oct. 17.2
May 5.9 Nov. 10.5
June 6.8 Dec. 6.8
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 294
294 HYDROLOGY
The available fall is 42 m. What size of reservoir will be necessary to give the greatest continu-
ous uniform output and what will be this power if the plant efficiency is 70%. If the largest
reservoir, which can be economically constructed has a capacity of 8.8 Mm
3
, what will be then
the greatest output?
2 (a) Give the method of finding out the size of reservoir using stream flow records and demand.
(b) The following is a record of mean monthly discharges of a river in a dry year:
Month Mean flow Month Mean flow
(cumec) (cumec)
April 56.6 Oct. 161.5
May 62.2 Nov. 133.0
June 119.0 Dec. 190.0
July 258.0 Jan. 212.3
Aug. 234.0 Feb. 184.0
Sept. 201.5 March 127.5
The average net head available is 30.5 m and the average efficiency of a hydro-electric plant may
be taken as 85%. Estimate the storage required to produce a firm power of 40 MW and the
maximum firm power available.
3 The monthly inflow into a reservoir is as follows:
Month Flow Month Flow
(Mm
3
) (Mm
3
)
Jan. 340 July 400
Feb. 360 Aug. 300
March 300 Sept. 310
April 270 Oct. 330
May 240 Nov. 350
June 290 Dec. 320
The water turbines have an output of 22.5 MW working under a net head of 24 m and overall
efficiency of 80%.
Determine the minimum capacity of the reservoir to satisfy the uniform demand for water and
the total quantity of water wasted during the year assuming that at the beginning of January,
the reservoir is full.
4 The quantity of water flowing in a river during each successive month is given below in Mm
3
.
4.2, 5.1, 8.5, 27.5, 45.3, 30.6, 14.2, 11.1, 10.2, 9.3, 8.8.
Determine the minimum capacity of a reservoir, if the above water is to be drawn off at a uni-
form rate and there should be no loss by flow over the spillway.
Also estimate the amount of water, which must be initially stored to maintain the uniform draw
off.
Also calculate the electrical energy that could be generated per year, if the average available
head is 36.5 m and the plant efficiency is 80%.
5 The following is a record of the power demand and of the streamflow taken in a day, for every
2-hr intervals (the record gives the average for the two hour periods).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 295
STORAGE, PONDAGE AND FLOW DURATION CURVES 295
Time Power demand Stream flow
(hr) (1000 kW) (cumec)
MN: 0-2 11.4 59.5
2-4 5.6 57.4
4-6 25.6 55.2
6-8 53.2 53.8
8-10 44.8 52.4
N: 10-12 39.4 51.0
12-14 44.2 49.6
14-16 44.4 51.0
16-18 74.2 52.4
18-20 37.8 53.8
20-22 30.0 55.2
22-24 18.0 56.6
The average net head available is 109.3 m. The average plant efficiency is 85%. Determine the
necessary storage, if the demand is to be just met.
6 Explain the significance of the terms; flow-duration curves, mass curves, pondage and storage.
State the limiting conditions for economic storage and utilization of water resources in a country
where the majority of rivers are not perennial?
Sketch one in which the power potential can be augmented further downstream.
7 Construct a mass curve from the following data of flow for a given site.
Weeks Weekly flow
(cumec)
1-6 600
7-12 700
13-18 300
19-24 400
25-30 1700
31-36 1300
37-42 900
43-48 600
49-52 300
Estimate the size of reservoir and the possible maximum rate of flow that could be available
from it. (5500 Mm
3
, 773 cumec)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 296
296 HYDROLOGY
8 The average weekly discharge as measured at a given site is as follows:
Week Flow Week Flow
(cumec) (cumec)
1 1000 14 1200
2 900 15 1000
3 909 16 900
4 800 17 800
5 800 18 500
6 600 19 400
7 500 20 400
8 500 21 300
9 800 22 300
10 800 23 400
11 1000 24 400
12 1100 25 500
13 1100 26 500
Plot
(a) the hydrograph of weekly flow.
(b) the flow-duration curve.
(c) the power-duration curve if the head available is 50 m and the efficiency of the turbine-
generator set is 85%.
Determine the power that can be developed per cumec, the maximum power, average power, and
total energy produced during 26 weeks. (417 kW, 485 MW, 300 MW, 1.31 GWh)
9 Average daily flows in a river in typical low water week are given below. A run-of-river plant is
proposed on this river to operate for 6 days in a week round the clock. The full pond effective
head on turbines is 20 m and the plant efficiency is 80%. Maximum allowable fluctuation of pond
level is 1 m.
Determine
(i) the capacity of the pond required to give a maximum uniform output.
(ii) the surface area of pond for satisfactory operation.
(iii) the weekly energy output (KWH) from the plant.
Day: Sun. Mon. Tues. Wed. Thurs. Fri. Sat.
Flow (cumec): 26 35 40 50 45 40 30
10 Typical weekly and daily releases of water from an upstream reservoir on a river are given
below. Estimate the pondage capacity to operate a run-of-river plant at downstream location so
that a steady uniform power output is available from the plant.
Weekly release pattern
Day: Sun. Mon. Tues. Wed. Thurs. Fri. Sat.
Flow: 25 30 40 50 40 35 25
release (cumec)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD10-1.PM5 297
STORAGE, PONDAGE AND FLOW DURATION CURVES 297
Daily release pattern
Time (hr): 0-6 6-12 12-18 18-24
% of ave. daily flow volume: 5 35 50 10
(Hint Pondage reqd. = weekly fluctuations + daily fluctuations)
11 During a low water week, the average daily flow in a river is 30 cumec and the pondage required
for the daily fluctuation is about 20% of the average daily flow. A run-of-river plant to be located
on the river is to operate 6 days a week, round the clock and is connected to a variable load with
a daily load factor of 50%. The pondage required for the daily load fluctuation may be taken as
about one-fifth of the mean flow to the turbine.
If the effective head on the turbine when the pond is full is 20 m and the maximum allowable
fluctuation in pond level is 1 m, determine
(i) the capacity of the pond and its surface area.
(ii) the weekly energy output (KWH).
Assume a plant efficiency of 80%.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 11
11.1 SEDIMENT MOVEMENT AND DEPOSITION
As the silt originates from the water shed, the characteristics of the catchment such its
areal extent, soil types, land slopes, vegetal cover and climatic conditions like temperature,
nature and intensity of rainfall, have a great significance in the sediment production in the
form of sheet erosion, gully erosion and stream, channel erosion. In regions of moderate rain-
fall, sheet erosion is the dominant source of total sediment load while in arid and semi-arid
regions, gullying and stream-channel erosion furnish the greater part of the load.
Experiments have shown that the erosive power of water, flowing with a velocity V,
varies as V
2
while the transporting ability of water varies as V
6
. Sediment moves in the
stream as suspended load (fine particles) in the flowing water, and as bed load (large parti-
cles), which slides or rolls along the channel bottom. Sometimes, the particles (small particles
of sand and gravel) move by bouncing along the bed, which is termed as saltation, which is a
transitional stage between bed and suspended load. The material, which moves as bed load at
one section may be in suspension at another section.
The suspended sediment load of streams is measured by sampling the water, filtering to
remove the sediment, drying and weighing the filtered material.
Sediment load, (ppm) =
weight of sediment in the sample
weight of sediment laden water sample
10
6
The samplers may be of depth-integrating type or point samplers. Point samplers are
used only where it is not possible to use the depth integrating type because of great depth of
high velocity, or for studies of sediment distribution in streams. The sample is usually col-
lected in pint bottle held in a sample of stream-lined body so as not to disturb the flow while
collecting a representative sample.
The relation between the suspended-sediment transport Q
s
and stream flow Q is given
by
Q
s
= KQ
n
...(11.1)
log Q
s
= log K + n log Q ...(11.1 a)
and is often represented by a logarithmic plot of Q
s
vs. Q (Fig. 11.1); Q
s
= K when Q = 1, and n
is the slope of the straight line plot and 2 to 3.
The sediment rating curve from a continuous record of stream flow provides a rough
estimate of sediment inflow to reservoirs and the total sediment transport may be estimated
by adding 10-20% to the suspended sediment transport to allow for the bed load contribution.
RESERVOIR SEDIMENTATION
298
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 299
RESERVOIR SEDIMENTATION 299
Q = K
s
1
1 10
10
2
10
3
10
4
10
5
Suspended sediment load Q (tons/day)
S
Sediment rating
curve
Q = KQ
S
n
Slope n =

x
Log - log paper
10
4
10
3
10
2
10
S
t
r
e
a
m
f
l
o
w
Q
(
c
u
m
e
c
)
y
x
Fig. 11.1 Sediment rating curve
When the sediment-laden water reaches a reservoir, the velocity and turbulence are
greatly reduced. The dense fluid-solid mixture along the bottom of the reservoir moves slowly
in the form of a density current or stratified flows, i.e., a diffused colloidal suspension having
a density slightly different from that of the main body of reservoir water, due to dissolved
minerals and temperature, and hence does not mix readily with the reservoir water (Fig. 11.2).
Smaller particles may be deposited near the base of the dam. Some of the density currents and
settled sediments near the base of the dam can possibly be flushed out by operating the sluice
gates. The modern multipurpose reservoirs are operated at various water levels, which are
significant in the deposition and movement of silt in the reservoir.
River
bed
Coarse
sediment
deposits Fine
sediment
deposits Dam
Sluices
Relatively clear
water D
e
n
s
ity
c
u
rre
n
t
Flow
Sediment
inflow Floating
debris
FRL
Fig. 11.2 Sediment accumulation in a reservoir
The total amount of sediment that passes any section of a stream is referred to as the
sediment yield or sediment production. The mean annual sediment production rates generally
range from 250-2000 tons/km
2
or 2.5-18 ha-m/100 km
2
and the Indian reservoirs are losing a
storage capacity of 0.5-1% annually.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 300
300 HYDROLOGY
The following figures give a general idea of the silt carried by some of the big rivers in
the world during floods:
River Silt content (% by weight)
Colorado (USA) 1.00
Mississippi-Missouri (USA) 0.20
Yangatze (China) 0.04
Yellow river (China) 4.00
Indus (Pakistan) 0.42
Sutlej (India) 1.67
Nile (Egypt) 0.15
Krishna (India) 1.00
Cauvery (India) 0.14
Tungabhadra (India) 0.67
Sone (India) 0.56
The sedimentation rate worked out by experts for different projects in India are given
below:
Project Annual sedimentation rate
(ham/100 km
2
)
Bhakra 6.00
Hirakund 3.89
Gandhisagar 10.05
Nizamsagar 6.57
Panchet 9.92
Maithon 13.02
Ramganga 17.30
Tungabhadra 6.00
Mayurakshi 20.09
Tawa 8.10
Dantiwada 6.32
Manchkund 2.33
11.2 REDUCTION IN RESERVOIR CAPACITY
The useful life of a reservoir gets reduced due to sediment deposition causing a decrease in its
storage capacity.The factors affecting the pattern of sediment deposition in reservoirs are:
(i) sediment load (i.e., sediment inflow rate)
(ii) sediment size (i.e., gradation of silt)
(iii) compaction of sediment (iv) river inflow pattern
(v) river valley slope (vi) shape of reservoir
(vii) capacity of reservoir (its size and storage period)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 301
RESERVOIR SEDIMENTATION 301
(viii) vegetal growth at the head
(ix) outlets in the dam (their types, location and size)
(x) reservoir operation
(xi) upstream reservoirs, if any.
It has been found by experience that a low sediment inflow rate, large fraction of fine
particles, steep slope, no vegetation at head of reservoir, low flow detention time in the reservoir
(by operation of outlets of suitable size at different levels), possibly series of upper tanks or
reservoir upstream (where deposition occurs) do not favour sediment deposition and compaction.
The silt carried in the rainy season may be excluded from the reservoir by means of scouring
sluices slightly above the deep river-bed, which discharge the heavily silt-laden water at high
velocity. The percent of the inflowing sediment, which is retained in a reservoir is called the
trap efficiency and it is a function of the ratio of reservoir capacity to total annual sediment
inflow, since a small reservoir on a large stream passes most of its inflow quickly (giving no
time for the silt to settle) while a large reservoir allows more detention time for the suspended
silt to settle. The relation between trap efficiency of reservoir vs. capacity-inflow ratio is shown
in Fig. 11.3 (Brune, 1953), on the basis of data from surveys of existing reservoirs. The rate at
which the capacity of a reservoir is reduced by sediment deposition depends on
(i) the rate of sediment inflow, i.e., sediment load.
(ii) the percentage of the sediment inflow trapped in the reservoir, i.e., trap efficiency.
(iii) the density of the deposited sediment.
Median curve for normal
ponded reservoirs
Semi-log paper
0.001 0.01 0.1 1 10
100
90
80
70
60
50
40
30
20
10
0
0.001 .002 .003 .005.007 0.01 0.02 .03 .05 .07 0.1 0.2 .3 .4 .6 .8 1.0 2 3 4 6 8 10
CapacityInflow: C- ratio) I
T
r
a
p
e
f
f
i
c
i
e
n
c
y
,
(
%
)
h
t
r
a
p
Fig. 11.3 Reservoir trap efficiency vs. capacity-inflow ratio (after Brune, 1953)
In estimating the useful life of a reservoir, the correct prediction of the density of the
deposited sediment is an important factor. Lane and Koelzer (1943) gave the equation for the
dry specific weight
t
after time t years as

t
=
i
+ K log
10
t ...(11.2)
where
i
= initial specific weight
K = a constant for the rate of compaction
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 302
302 HYDROLOGY
If the deposited sediment consists of a mixture of materials like sand, silt and clay, a
weighted average specific weight is calculated as (Lane and Koelzer).

t
=
1
x
1
+ (
2
+ K
2
log t) x
2
+ (
3
+ K
3
log t) x
3
...(11.2 a)
where
t
= average specific weight of reservoir sediment after t years

1, 2, 3
= specific weight of sand, silt and clay after t years
K
1, 2, 3
= constant for the rate of compaction of sand, silt and clay, respectively (K
1
0, for
sand)
x
1, 2, 3
= fractional part of total sediment, of sand, silt and clay, respectively
t = time in years (1 yr)
The useful capacity of reservoir lost each year by sediment deposition is
V
s
= Q
s

trap
...(11.3)
where V
s
= volume of useful capacity of reservoir lost each year
Q
s
= annual sediment inflow into the reservoir

trap
= trap efficiency of the reservoir
while allocating space for the dead storage in the reservoirs (i.e., to provide space for sediment
deposition during the life of the project) the trap efficiency is taken as at least 95% and rarely
below 90%. Sediment deposits in the upper end of the reservoirs generally become covered by
vegetation resulting in heavy evapotranspiration loss of the available water, which is more
critical in arid regions.
Example 11.1 A proposed reservoir has a capacity of 400 ha-m. The catchment area is 130 km
2
and the annual stream flow averages 12.31 cm of runoff. If the annual sediment production is
0.03 ha-m/km
2
, what is the probable life of the reservoir before its capacity is reduced to 20% of
its initial capacity by sediment deposition. The relation between trap efficiency and capacity-
inflow ratio is given below.
Capacity-inflow Trap Capacity-inflow Trap
ratio,
C
I
efficiency, ratio,
C
I
efficiency,

trap
(%)
trap
(%)
0.1 87 0.002 2
0.2 93 0.003 13
0.3 95 0.004 20
0.4 95.5 0.005 27
0.5 96 0.006 31
0.6 96.5 0.007 36
0.7 97 0.008 38
1.0 97.5 0.01 43
0.015 52
0.02 60
0.03 68
0.04 74
0.05 77
0.06 80
0.07 82
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 303
RESERVOIR SEDIMENTATION 303
Solution The useful life may be computed by determining the number of years required for
each incremental loss of reservoir capacity (i.e., for the decreasing values of capacity-inflow
ratios) upto the critical storage volume of 400 0.20 = 80 ha-m as tabulated below:
Trap efficiency Loss of No. of years
Capacity Capacity*
trap
(%) Annual** reservoir for the
C inflow sediment capacity capacity
(ha-m) ratio for the Ave. for trapped C loss
C
I
C
I
ratio *increment V
s
= Q
s

trap
(ha-m) C V
s
400 0.25 94
320 0.20 93 93.5 3.64 80 22.0
240 0.15 90 91.5 3.57 80 22.4
160 0.10 87 88.5 3.45 80 23.2
80 0.05 77 82.0 3.20 80 25.0
Total = 92.6
say, 93 yr
*Average annual inflow, I =
12 31
100
130 10
10
6
4
.

= 1600 ha-m
For reservoir capacity C = 400 ha-m,
C
I
=
400
1600
= 0.25
**Annual sediment inflow into the reservoir
Q
s
= 0.03 130 = 3.9 ha-m
Note: If the average annual sediment inflow Q
s
is given in tons, say Q
s
= 43600 tons and for

trap
= 93.5% (for the first incremental loss), assuming a specific gravity of 1.12 for the sediment depos-
its, annual sediment trapped W
s
= 43600 0.935 = 40750 tons.
V
s
=
W
s
s

=
40750 1000 kg
1.12 1000 kg/m
3

=
40750
1.12
m
3
= 3.64 ha-m.
Usually the specific gravity of sediments deposits ranges from 1 to 1.4.
11.3 RESERVOIR SEDIMENTATION CONTROL
Sediment deposition in reservoirs can not be actually prevented but it can be retarded by
adopting some of the following measures:
(i) Reservoir sites, which are prolific sources of sediment should be avoided.
(ii) By adopting soil-conservation measures in the catchment area, as the silt originates
in the watershed. See art 8.7 in Chapter 8.
(iii) Agronomic soil conservation practices like cover cropping, strip cropping, contour
farming, suitable crop rotations, application of green manure (mulching), proper control over
graze lands, terracing and benching on steep hill slopes, etc. retard overland flow, increase
infiltration and reduce erosion.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 304
304 HYDROLOGY
(iv) Contour trenching and afforestation on hill slopes, contour bunding gully plugging
by check dams, and stream bank stabilisation by the use of spurs, rivetments, vegetation, etc.
are some of the engineering measures of soil conservation.
(v) Vegetal cover on the land reduces the impact force of rain drops and minimises
erosion.
(vi) Sluice gates provided in the dam at various levels and reservoir operation, permit
the discharge of fine sediments without giving them time to settle to the bottom.
(vii) Sediment deposits in tanks and small reservoirs may be removed by excavation,
dredging, draining and flushing either by mechanical or hydraulic methods and sometimes
may have some sales value.
OUZ X
I Match the items in A with the items in B
A B
(i) Gullying and stream (a) V
6
Channel erosion
(ii) Measurement of suspended sediment (b) V
2
(iii) Erosive power of water (c) Capacity-inflow ratio
(iv) Transporting capacity of water (d) Soil conservation
(v) Saltation (e) Bouncing along bed
(vi) Trap efficiency (f) Semi-arid regions
(vii) Sedimentation control (g) Point samplers
II Say true or false; if false, give the correct statement:
(i) While sheet erosion is dominant in regions of moderate rainfall, gullying and stream channel
erosion are characteristic of arid and semi-arid regions.
(ii) Density current is a stratified flow along the bottom of the reservoir and mixes readily with
the reservoir water.
(iii) The per cent of the inflowing sediment in a stream retained by a reservoir is called the trap
efficiency of the reservoir.
(iv) The trap efficiency of a reservoir is a function of the ratio of the reservoir capacity to the
average annual sediment inflow, and as this ratio decreases the trap efficiency increases.
(v) Silting of reservoirs can be controlled by
(a) proper agronomic practices.
(b) adopting soil-conservation measures.
(c) by providing sluice gates at various levels in the dam and proper reservoir operation.
(false: ii, iv)
III Choose the correct statement/s:
Siltation of reservoir can be reduced by
(i) proper reservoir operation.
(ii) providing sluice gates at different levels.
(iii) land management.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD11-1.PM5 305
RESERVOIR SEDIMENTATION 305
(iv) gully plugging, check dams and contour bunds in the catchment area.
(v) strip cropping, contour farming and afforestation of hill slopes.
(vi) providing dead storage.
(vii) all the above steps. (except vi)
OUE8TON8
1 (a) What are the factors which contribute for silt in a natural stream?
(b) How will you determine the quantity of silt deposited in a reservoir?
(c) Recommend the measures for controlling the silt entry into reservoirs.
2 (a) How would you determine the sediment load carried by a stream?
(b) What do you understand by density current?
(c) Explain the terms:
(i) Saltation (ii) Suspended load
(iii) Bed load (iv) Contact load
3 (a) Briefly give the theory of distribution and transporation of suspended material and derive
the formula connecting the concentration of sediment and settling velocity under equilib-
rium conditions.
(b) Explain how sedimentation in a reservoir can be controlled.
(Hint: for Q 3 (a) supplementary reading)
4 (a) Describe a method by which silt accumulation in a reservoir can be computed and its useful
life determined.
(b) An impounding reservoir had an original storage capacity of 740 ha-m. The catchment area
of the reservoir is 100 km
2
, from which the annual sediment discharge into the reservoir is
at the rate 0.1 ha-m/km
2
. Assuming a trap efficiency of 80%, find the annual capacity loss of
the reservoir in percent per year. (1.3%/year)
5 A proposed reservoir has a capacity of 600 ha-m. The catchment area is 147 km
2
and the annual
streamflow averages 17 cm of runoff. If the annual sediment production is 0.035 ha-m/km
2
what
is the probable life of the reservoir before its capacity is reduced to 20% of its initial capacity by
sediment deposition. The relation between trap efficiency and capacity-inflow ratio is given
below:
Capacity
Inflow
ratio
Trap
Capacity
Inflow
ratio
Trap
efficiency efficiency
(%) (%)
0.1 87 0.01 43
0.2 93 0.02 60
0.3 95 0.03 68
0.4 95.5 0.05 77
0.5 96.0 0.07 82
0.6 96.5
0.7 97
1.0 97.5
(97 yr)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 12
Climates can be classified on the basis of temperature, barometric pressure, humidity,
sunshine, evaporation, rainfall and prevailing winds in a particular place or region. From the
viewpoint of irrigation, the classification based on rainfall is reasonable, i.e., if
a.a.r. < 40 cm arid climate
a.a.r. = 4075 cm semi-arid climate
a.a.r. > 75 cm humid climate
We have all the three classes of climatic zones (regions) in India and the hydro meteoro-
logical processes peculiar to each climate have to be studied in detail for optimum water re-
sources utilisation and irrigation (crop) planning or agricultural practice. Some of the charac-
teristic features of each type of climatic region are enumerated below:
12.1 ARID REGIONS
(i) a.a.r. < 40 cm; a drought is a normal state of affairs, and while calculating runoff
each fall of rain has to be considered as a separate unit.
(ii) A little rainfall occurs once in a while with a wide variability with respect to time
and space.
(iii) A very high temperature and hot climate; there is scarcity of water; unfit for irriga-
tion and no regular crops can be grown.
(iv) Evaporation losses are very high. Any slight precipitation will be lost by evapora-
tion; water has to be applied to crops by special methods like drip and sprinkler irrigation;
salt-concentration problems occur in irrigated soils near root zones.
(v) Rainfall is mostly during summer and is given by
R < (T + 14)
where R = annual rainfall in cm
T = average annual temperature in C
The arid zone of Rajasthan receives 40 cm of rainfall per year.
(vi) Streams carry only surface runoff and flow immediately following periods of intense
rainfall; hence, they are intermittent.
(vii) The ground water table if at all exists, is very deep and is always below the bed of
the stream; most of the streams are ephemeral.
306
ARID, SEMI-ARID AND HUMID REGIONS
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD12-1.PM5 307
ARID, SEMI-ARID AND HUMID REGIONS 307
(viii) The infiltration capacity of the soil is nearly constant throughout the year. All the
infiltration may be considered as a water loss and the water once infiltered never reaches the
stream draining the basin nor the ground water storage has any significance.
(ix) From the records of a number of intense storms and their hydrographs of surface
runoff, the average infiltration capacity of a basin can be determined. This average value can
be applied to each intense storm and the resulting runoff can be found.
(x) Afforestation provides a mechanical obstacle to the free sweep of wind, reducing in
the process the wind velocity, soil erosion and evaporation from soil.
(xi) Sand dune stabilisation is considered an important work in the arid regions of
Rajasthan, as sand dunes with varying frequency are spread over 58% of the arid zone of
Rajasthan. The Central Arid Zone Research Institute (CAZRI) at Jodhpur has directed its
efforts towards control of desertification through afforestation and sand dune stabilisation
(since wind-swept sand from deserts can bury anything coming in the way).
(xii) Reduction in grazing landIn the arid parts, like those of Rajasthan, the popula-
tion density is 48 persons per km
2
compared to 3 per km
2
in most other deserts of the world.
Along with the rise in the human population, the livestock population too is on the increase
( 200 per ha). The result has been over use of the grazing land and depletion of natural
vegetation resources. More and more marginal land is being brought under the plough, reduc-
ing the area of grazing land, trees and shrubs. The increase in rainfed farming on marginal
lands has not only resulted in decline in crop productivity per unit area, but also enhanced soil
erosion, degraded soil fertility and led to over-exploitation of ground waters. The CAZRIs
efforts are to be viewed against this background.
(xiii) Exotic speciesThe CAZRI has shown that about 25% of the area now under culti-
vation should be brought under cover of grass and trees. CAZRI has focussed its efforts on the
introduction of exotic fast-growing tree and shrub species from iso-climatic regions of the world.
The species Acacia Tortilis (Israeli Babool) has been found to be the best fuel-cum-fodder spe-
cies for dry zones. Ber is one of the main fruit plants of the region and CAZRI has developed
the technology to cut short the time required to raise a Ber Orchard from the normal one year
to just four months.
The grafted plants of improved varieties are raised in polythene tubes. To make it popu-
lar, a programme of budding of two improved varieties on the root stock of the common local
bush has been undertaken.
12.2 SEMI-ARID REGIONS
(i) The a.a.r. = 40 to 75 cm; a semi-arid region usually receives precipitation during
winter and spring.
(ii) Rainfall occurs during a particular season of the year and it may be virtually non-
existant in other parts of the year.
(iii) Only during the rainy season, the stream flow is continuous; during the dry season
the stream becomes dry most of the time and carries water intermittently after an occasional
heavy storm. The stream flows are usually of too short duration to develop a stable channel
section and occasional high flood flows may change the cross-section radically.
(iv) Moderate precipitation and temperature higher than normal. The usual methods of
determining mean precipitation by constructing Thiessen Polygons or by arithmetic mean are
impracticable. Isohyetal maps should be used as the precipitation varies with time and area.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD12-1.PM5 308
308 HYDROLOGY
Average elevation-precipitation curves from precipitation data will be more useful for semi-
arid regions.
R lies between (T + 14) and 2 (T + 14) ...(12.2)
where R = annual rainfall in cm
T = annual average temperature in C
(v) Major loss of water is by evapotranspiration and the evapotranspiration losses range
from 40 cm/year for barren rocky areas to 90 cm/year for heavy forest areas.
(vi) The ground water table occurs at moderate depth.
(vii) Wide variability of hydrologic factors with respect to time and space are a charac-
teristic feature; for example, vegetative cover may vary radically across a basinthick vegeta-
tion in higher altitudes and barren land in lower reaches.
A high elevation zone of a river basin may get precipitation regularly while other parts
of the basin may not get; 90% of runoff may result from 10% of the drainage area. Runoff
values expressed as flow per km
2
of drainage area may be inapplicable.
Hydrologic factors occurring in one season may be virtually non-existant during an-
other season.
As geology of the basin differs from place to place, the infiltration rate too differs.
(viii) Seasonal crops like jowar, ragi etc. can be grown.
(ix) Probability and duration studies (flow duration, drought duration) are essential to
determine the available flow or drought period in a long term climatalogical cycle (or swing).
(x) A drought occurs at least once in a year except in abnormal years,
(xi) Even in a single river basin, the hydrological processes in semi-arid regions differ
from area to area.
(xii) Mean depth of precipitation. In semi-arid regions where the precipitation is controlled
by the topography, the pattern of rainfall distribution can be studied by isopercentral map.
Such maps should be prepared for individual and isolated storms. By adopting isoper-central
method, a comparatively small number of stations can be used to develop a quite detailed
isohyetal map. This method of finding the mean precipitation over the basin will avoid errors
caused by imperfect distribution of raingauge stations.
Because of the characteristic variability of precipitation in semi-aird mountainous re-
gions, direct transposition of either isohyetal pattern or depth-area values from one river basin
to another may lead to quite unreasonable results.
(xiii) The unit hydrograph technique can not be used in semi-arid regions, as it requires
constancy of hydrologic factors over a river basin.
(xiv) Semi-arid and desert regions of Rajasthan. Rajasthan (n-w India) has a total area of
330000 km
2
, which is sandy and unproductive with scanty rainfall and very low water table.
About 90% of the rainfall occurs during the monsoon period, June to September. The evapora-
tion is very high of the order of 300 cm and much of the rainfall is quickly evaporated, though
some portion of it sinks into the earth to replenish the ground water.
The conditions in the semi-arid regions are better than the desert lands. Some portion,
particularly the Luni basin, can probably be improved if suitable conservation, storage and
irrigation methods are adopted. For planning the reclamation of the desert and semi-desert
regions of Rajasthan, it is necessary to have proper study of meteorological conditions based
on detailed observations of rainfall, evaporation, humidity and other meteorological elements.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD12-1.PM5 309
ARID, SEMI-ARID AND HUMID REGIONS 309
(xv) Silting. While sheet erosion is dominant in regions of moderate rainfall, gullying
and stream channel erosion are characteristic of arid and semi-arid regions. Sediment depos-
its in the upper end of reservoirs generally become covered by vegetation resulting in heavy
evapotranspiration loss of the available water, which is more critical in arid regions.
12.3 HUMID REGIONS
(i) High intensity of rainfall (a.a.r. > 75 cm) with not much variability with respect to
time and space.
(ii) High precipitation, low temperature and minimum loss of water. Transpiration is
the major water loss amounting upto 80%.
(iii) Flow in streams is continuous and the ground water table is always above the bed
level of the stream, i.e., the streams are mostly perennial.
(iv) The ground water table is usually at very high elevation and the ground water con-
tributes to streamflow. The change in ground water storage becomes significant.
(v) Average annual yield can be satisfactorily determined from a comparatively short
period of records.
(vi) Best suited for irrigation and agriculture. Crops can be grown throughout the year
due to availability of water supply throughout.
(vii) A drought does not occur in ordinary years.
OUZ X
I Choose the correct statement/s in the following:
1 In an arid region
(i) rainfall is mostly during summer (ii) each fall of rain is considered as a separate unit
(iii) drought-duration studies are essential (iv) major loss is by transpiration
(v) drip irrigation is preferred (vi) ephemeral streams are common
(vii) seasonal crops can be grown (viii) all the above characteristics
2 In a semi-arid region
(i) precipitation is only during winter or spring
(ii) rainfall is only seasonal
(iii) Intermittent streams are common
(iv) isopercentral maps are prepared for individual or isolated storms
(v) seasonal crops like jowar, ragi, etc. can be grown
(vi) flow-duration and drought-duration studies are essential
(vii) Unit hydrograph method can be applied
(viii) Gullying and stream-channel erosion is a characteristic feature
(ix) all the above characteristics
3 In a humid region
(i) uniformly high rainfall occurs (ii) transpiration is the major water loss
(iii) streams are mostly perennial (iv) intensive irrigation is possible
(v) drought normally does not occur (vi) change in ground water storage is significant
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD12-1.PM5 310
310 HYDROLOGY
(vii) high evaporation losses occur (viii) all the above characteristics.
[1(v), (vi); 2except (vii); 3except (vii)]
II Match the items in A with items in B (more than one item in B may fit):
A B
(i) Semi-arid region (a) Arid region
(ii) Arid region (b) Semi-arid region
(iii) Drip irrigation (c) Normally drought conditions
(iv) Seasonal crops (d) Transpirationmajor water loss
(v) Probability and duration studies (e) GWT very high
(vi) Humid region (f) High temperature
(g) Low temperature
(h) Isopercentral map
(i) Ephemeral streams
(j) High evaporation losses
(k) a.a.r. = 4075 cm
(l) a.a.r. < 40 cm
III Say true or false, if false, give the correct statement:
(i) High evaporation losses are significant in arid regions while transpiration is the major water
loss in humid regions.
(ii) In arid regions, the rainfall occurs mostly during summer and the rainfall (R) in cm is given
by: R = T + 14, while in semi-arid regions, the rainfall is mostly during winter and spring and
R lies between (T + 14) and 2(T + 14), where T is the annual average temperature in C.
(iii) In arid regions, the infiltration capacity of the soil varies throughout the year.
(iv) Ephermeral streams are quite common in semi-arid regions.
(v) Salt-concentration problems occur in irrigated soils and hence water has to be applied to
crops by drip or sprinkler irrigation methods, in arid regions.
(vi) Seasonal crops like jowar, ragi, etc., can not be grown in semi-arid regions.
(vii) Probability and duration studies (drought duration and flow duration) are essential to deter-
mine the available flow or drought period in a long-term climatological cycle (or swing) in
arid and semi-arid regions.
(viii) Non-variability of hydrological factors with respect to time and space are characteristic fea-
tures of arid and semi-arid regions.
(ix) In arid regions, the pattern of rainfall distribution (development of isohyetal map) can be
studied by isopercentral map.
(x) Transposition of either the isohyetal pattern or depth-area values from one river basin to
another may give eroneous results in semi-arid mountainous regions.
(xi) Unit hydrograph technique can be used for semi-arid regions.
(xii) High precipitation (a.a.r > 75 cm) and low temperature are characteristic of humid regions
and crops can be grown throughout the year.
(xiii) While drought is a usual state of affairs in an arid region, it does not occur in ordinary years
in a humid region.
(xiv) A drought occurs at least once in a year in a semi-arid region, except in abnormal years.
(false: iii, iv, vi, viii, ix, xi)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD12-1.PM5 311
ARID, SEMI-ARID AND HUMID REGIONS 311
OUE8TON8
1 Discuss the hydrological processes peculiar to arid and semi-arid regions. Explain the method of
computing mean depth of precipitation in semi-arid zones.
2 (a) Explain arid and semi-arid regions.
(b) Explain briefly the surface-drainage characteristics that are peculiar to arid and semi-arid
regions.
(c) What parts of India can be classified as semi-arid?
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
THIS PAGE IS
BLANK
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
PART B
ADVANCED TOPICS
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
THIS PAGE IS
BLANK
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 13
315
LINEAR REGRESSION
13.1 FITTING REGRESSION EQUATION
The fitting of a straight line may be done objectively by one of the following statistical
methods:
(a) The method of least squares
(b) The method of moments
(c) The method of maximum likelihood
In this chapter, the method of least squares is used. Two variables y (dependent) and x
(independent) can be correlated by plotting them on x and yaxis. If they are plotted on a
straight line, there is a close linear relationship; on the other hand, if the points depart appre-
ciably (without a definite trend), the graph is called a scatter diagram or plot.
If the trend is a straight line, the relationship is linear and has the equation
y = a + bx ...(13.1)
Number of lines can be obtained depending on the values of a and b. The method of least
squares is used to select the line that fits the data best. The principle of least squares states
that the best line for fitting a series of observations is the one for which the sum of the squares
of the departures is minimum. A departure is the difference between the observed value and
the line. Since x is the independent variable, the departures of y are used.
The least squares line Eq. (13.1) may be obtained by solving for a and b, the two normal
equations
y = na + b x
xy = a x + b x
2
...(13.2)
where n = number of pairs of observed values of x and y.
The most commonly used statistical parameter for measuring the degree of association
of two linearly dependent variables x and y, is the correlation coefficient
r =


( . )
( ) . ( )
x y
x y
2 2
...(13.3)
=
xy nx y
n
x y

( ) 1
...(13.3 a)
where x = x
x
, y = y y

x
,
y
= standard deviations of x and y, respectively
x, y = middle of each class interval, respectively
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 316
316 HYDROLOGY
If r = 1, the correlation is perfect giving a straight line plot (regression line).
r = 0, no relation exists between x and y (scatter plot).
r 1, indicates a close linear relationship.
If a linear regression can not be fitted, a quadratic parabola can be used as the fitting
curve, given by
y = a + bx + cx
2
...(13.4)
From the principles of least squares, a, b and c can be obtained by solving the three
normal equations
y = na + bx + c x
2
xy = ax + b x
2
+ c x
3
x
2
y = ax
2
+ b x
3
+ c x
4
...(13.5)
where n = number of pairs of observed values of x and y.
Regardless of the type of curve fitted, the correlation coefficient r is given by Eq. (13.3).
The variables x and y, for instance, may be precipitation and the corresponding runoff, or
gauge height and the corresponding stream flow, and like that.
For the exponential function y = cx
m
...(13.6)
it can be transformed to a straight line by using logarithms of the variables as
log y = log c + m log x ...(13.7)
By putting log x = X, log y = Y, log c = a and m = b the function becomes similar to Eq.
(13.1), can be solved for a and b from Eq. (13.2) and the exponential function can be deter-
mined.
Whichever fitting gives r 1 by Eq. (13.3), that curve fitting is adopted. Statistical
method can be applied to many kinds of meteorological data, such as precipitation, tempera-
ture, floods, droughts, and water quality.
13.2 STANDARD ERROR OF ESTIMATE
A measure of the scatter about the regression line of y on x in Eq. (13.1) is given by
S
y.x
=
( ) y y
n
est

2
2
...(13.8)
which is called the standard error of estimate of y with respect to x; and y
est
is the value of y
for the given value of x in Eq. (13.1). S
y.x
can also be determined by the expressions
S
y.x
=
y

1
2
r
...(13.9)
S
y.x
=
y a y b xy
n
2
2

...(13.10)
S
y.x
=
n
n
b
y x

1
2
2 2 2
( ) ...(13.11)
Eq. (13.10) can be extended to non-linear regression equations.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 317
LINEAR REGRESSION 317
Example 13.1 Annual rainfall and runoff data for the Damodar river at Rhondia (east India)
for 17 years (1934-1950) are given below. Determine the linear regression line between rainfall
and runoff, the correlation coefficient and the standard error of estimate.
Year Rain fall Runoff
(mm) (mm)
1934 1088 274
35 1113 320
36 1512 543
37 1343 437
38 1103 352
39 1490 617
40 1100 328
41 1433 582
42 1475 763
43 1380 558
44 1178 492
45 1223 478
46 1440 783
47 1165 551
48 1271 565
49 1443 720
1950 1340 730
Solution The regression line computations are made in Table 13.1 and is given by
R = 0.86 P 581
where P = rainfall (mm) and R = runoff (mm)
The correlation coefficient r = 0.835, which indicates a close linear relation and the
straight line plot is shown in Fig. 13.1, the relation is very close.
Standard error of estimate
S
y.x
=
y
1
2
r

y
=
( ) y y
n

2
1
=
( ) y
n
2
1
=
40 10 10
17 1
4
.

= 160 mm
S
y.x
= 160
1 0 835
2
( . )
= 90.24 mm
As an assignment problem, the relation between the staff gauge reading (water stage)
h and the stream discharge Q, for the stage-discharge data given in Example 6.2 may be
established by the method of least squares.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 318
318 HYDROLOGY
T
a
b
l
e

1
3
.
1

R
e
g
r
e
s
s
i
o
n

l
i
n
e

f
o
r

t
h
e

R
a
i
n
f
a
l
l
-
r
u
n
o
f
f

d
a
t
a

f
o
r

r
i
v
e
r

D
a
m
o
d
a
r

(
1
9
3
4
-
1
9
5
0
)
.

(
E
x
a
m
p
l
e

1
3
.
1
)
R
a
i
n
f
a
l
l
R
u
n
o
f
f
(
m
m
)

x
(
m
m
)

y
x
2


1
0
4
x
y


1
0
4

x

=

x

y

=

y


y
(

x
)
2


1
0
4
(

y
)
2


1
0
4

x
.


1
0
4
W
o
r
k
i
n
g
1
0
8
8
2
7
4
1
1
8
.
4
2
9
.
8


2
1
2


2
6
1
4
.
5
0
6
.
8
1
5
.
5
4
x
x
n
=
=

2
2
0
9
7
1
7

=

1
3
0
0

m
m
1
1
1
3
3
2
0
1
2
4
.
0
3
5
.
6


1
8
7


2
1
5
3
.
5
0
4
.
6
3
4
.
0
2
1
5
1
2
5
4
3
2
2
9
.
0
8
2
.
2
+

2
1
2
+

8
4
.
5
0
0
.
0
1
0
.
1
7
y
y
n
=
=

9
0
9
3
1
7

=

5
3
5

m
m
1
3
4
3
4
3
7
1
8
0
.
2
5
8
.
8
+

4
3


9
8
0
.
1
8
0
.
9
6
0
.
4
2
1
1
0
3
3
5
2
1
2
2
.
0
3
8
.
9


1
9
7


1
8
3
3
.
8
8
3
.
3
5
3
.
6
1
N
o
r
m
a
l

e
q
u
a
t
i
o
n
s
:
*

E
q
s
.

(
1
3
.
2
)
1
4
9
0
6
1
7
2
2
2
.
0
9
2
.
0
+

1
9
0
+

8
2
3
.
6
2
0
.
6
7
1
.
5
6
9
0
9
3

=

1
7

a

+

2
2
0
9
7

b

(
i
)
1
1
0
0
3
2
8
1
2
1
.
0
3
6
.
0


2
0
0


2
0
7
4
.
0
0
4
.
2
8
4
.
1
4
1
2
1
3
.
3


1
0
4

=

2
2
0
9
7

a
1
4
3
3
5
8
2
2
0
5
.
0
8
3
.
5
+

1
3
3
+

4
7
1
.
7
7
0
.
2
2
0
.
6
5
+

2
9
1
0


1
0
4
b
1
4
7
5
7
6
3
2
1
7
.
0
1
1
2
.
6
+

1
7
5
+

2
2
8
3
.
0
6
5
.
1
0
3
.
9
9
D
i
v
i
d
i
n
g

t
h
r
o
u
g
h
o
u
t

b
y

1
0
4
,
1
3
8
0
5
5
8
1
9
0
.
5
7
7
.
0
+

8
0
+

2
3
0
.
6
4
0
.
0
5
0
.
1
8
1
2
1
3

=

2
.
2

a

+

2
9
1
0
b

(
i
i
)
1
1
7
8
4
9
2
1
3
8
.
6
5
7
.
8


1
2
2


4
3
1
.
4
9
0
.
1
9
0
.
5
2
S
o
l
v
i
n
g

(
i
)

a
n
d

(
i
i
)
1
2
2
3
4
7
8
1
4
9
.
8
5
8
.
5


7
7


5
7
0
.
5
9
0
.
3
3
0
.
4
4
a

=


5
8
1
,

b

=

0
.
8
6
1
1
4
0
7
8
3
2
0
7
.
0
1
1
2
.
8
+

1
4
0
+

2
4
8
1
.
9
6
6
.
1
5
3
.
4
8
1
1
6
5
5
5
1
1
3
6
.
0
6
4
.
2


1
3
5
+

1
6
1
.
8
2
0
.
0
3
0
.
2
2

R
e
g
r
e
s
s
i
o
n

l
i
n
e

i
s
1
2
7
1
5
6
5
1
6
2
.
0
7
1
.
8


2
9
+

3
0
0
.
0
8
0
.
0
9
0
.
0
9
y

=

0
.
8
6
x


5
8
1
1
4
4
3
7
2
0
2
0
8
.
0
1
0
4
.
0
+

1
4
3
+

1
8
5
2
.
0
5
3
.
4
3
2
.
6
5
o
r
R

=

0
.
8
6
P


5
8
1
1
3
4
0
7
3
0
1
7
9
.
5
9
7
.
8
+

4
0
+

1
9
5
0
.
1
6
3
.
8
0
0
.
7
8
w
h
e
r
e

R

a
n
d

P

a
r
e

i
n

m
m


=

2
2
0
9
7
9
0
9
3
2
9
1
0


1
0
4
1
2
1
3
.
3


1
0
4
3
7
.
8
1


1
0
4

4
0
.
0
9


1
0
4

3
2
.
4
6


1
0
4
*
M
a
t
r
i
x

f
o
r
m

f
o
r

c
o
m
p
u
t
e
r

s
o
l
u
t
i
o
n

o
f

E
q
s
.

(
1
3
.
2
)
:
y

=

a

+

b
x
.
.
.
E
q
n
.

(
1
3
.
1
)

i
x
x
x
a b
y
x
y
i
n
m
2
L N M
O Q P
L N M
O Q P
=
L N M
O Q P
=
,
(
)
o
r
b

=

x
y
x
y
. .
. .
.
2
2
4 4
3
2
4
6
1
0
3
7
8
1
1
0
0
8
6
=

=
a

=

y


b
x

=

5
3
5


0
.
8
6


1
3
0
0

=


5
8
1
S
e
e

E
x
a
m
p
l
e

1
3
.
4
.
a
l
s
o
,
b

=

r


y x
F H G
I K J

=

r

y x
2 2
0
.
8
6

=

r

4
0
0
9
1
0
3
7
8
1
1
0
4 4
. .

r

=

0
.
8
3
5
C
o
r
r
e
l
a
t
i
o
n

c
o
e
f
f
i
c
i
e
n
t
r

=

x
y
x
y
. .
2
2
=

=
3
2
4
6
1
0
3
7
8
1
4
0
0
9
1
0
0
8
3
5
4
8
.
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 319
LINEAR REGRESSION 319
32
40
R
e
g
r
e
s
s
i
o
n
l
i
n
e
:
R
=
0
.
8
P

5
0
7
Rainfall - runoff data
for river Damodar,
1934 - 1950, at Rhondia
Graphical
plot on
x-, & y-axes
Slope m =
When x = 0, y = 507 mm
= 0.8
32
40
Points plotted
800
700
600
500
400
300
200
100
0
R
u
n
o
f
f
R
(
m
m
)
1000 1100 1200 1300
Rainfall P (mm)
1400
Fig. 13.1 Linear regression of Rainfall-Runoff (Example 13.1)
13.3 LINEAR MULTIPLE REGRESSION
A regression equation for estimating a dependent variable, say x
1
, from independent variables
x
2
, x
3
, ... is called a regression equation of x
1
on x
2
, x
3
, ... and like that; for three variables, it is
given by
x
1
= a + bx
2
+ cx
3
...(13.12)
The constants, a, b and c can be determined by the method of least squares. The least
square regression plane of x
1
on x
2
and x
3
can be determined by solving simultaneously the
three normal equations
x
1
= an + b x
2
+ c x
3
x
1
x
2
= a x
2
+ b x
2
2
+ c x
2
x
3
...(13.13)
x
1
x
3
= a x
3
+ b x
2
x
3
+ c x
3
2
where n is the set of data points (x
1
, x
2
, x
3
)
The standard error of estimate of x
1
, with respect to x
2
and x
3
is given by
S
1.23
=
( ) x x
n
est 1 1
2
3

...(13.14)
where x
1 est
= value of x
1
for the given value of x
2
and x
3
in Eq. (13.12).
The coefficient of multiple correlation is given by
r
1.23
=
1
1
2
S
1.23
2

...(13.15)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 320
320 HYDROLOGY
where
1
= standard deviation of x
1
and r
1.23
2
is called the coefficient of multiple determination.
The value of r
1.23
lies between 0 and 1. Also
r
1.23
=
r r r r r
r
12
2
13
2
12 13 23
23
2
2
1
+ +

...(13.16)
r
1.23
= 1 1 1
12
2
13
2
( )( ) r r ...(13.17)
where r
12
=
x x nx x
n
1 2 1 2
1 2
1

( )
...(13.18)
r
12
= the linear correlation coefficient between the variables
x
1
and x
2
, ignoring the variable x
3
; and similarly r
13
and
r
23
. r
12
, r
13
, r
23
are partial correlation coefficients.
From Eq. (13.15)
S
1.23
=
1
1
1
2
r
.23
...(13.19)
very similar to Eq. (13.9).
Example 13.2 The following are the data of the monthly Ground Water Table (GWT)
fluctuations, precipitation and ground water pumping in the Cauvery delta in Thanjavur, TN
Obtain the regression line connecting GWT fluctuations with the precipitation and pumping.
Month GWT below Precipitation G.W. pumping
MP (m) (mm) rate (Mm
3
)
Jan. 3.60 30 14.0
Feb. 4.05 52 23.4
March 4.12 95 32.4
April 4.57 90 51.2
May 4.80 200 62.3
June 4.95 280 79.5
July 5.02 168 61.4
Aug. 4.80 51 47.4
Sept. 4.42 18 34.4
Oct. 4.20 27 18.9
Nov. 3.90 52 1.8
Dec. 3.30 57 5.2
Solution The regression line computations are made in Table 13.2 and the normal equations
are given below:
12a + 1120b + 432c = 51.73
1120a + 17.15 10
4
b + 5.83 10
4
c = 5138.8
432a + 5.83 10
4
b + 1.68 10
4
c = 1997.1
Simultaneous solution of the three equations gives
a = 4.02, b = 0.00865, c = 0.0144
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 321
LINEAR REGRESSION 321
T
a
b
l
e

1
3
.
2

M
u
l
t
i
p
l
e

r
e
g
r
e
s
s
i
o
n

o
f

G
W
T

f
l
u
c
t
u
a
t
i
o
n
s

w
.
r
.
t
.

p
r
e
c
i
p
i
t
a
t
i
o
n

a
n
d

p
u
m
p
i
n
g
.

(
E
x
a
m
p
l
e

1
3
.
2
)
M
o
n
t
h
G
W
T
P
r
e
c
i
p
i
-
P
u
m
p
i
n
g
x
2
2
x
3
2
x
1
x
2
x
1
x
3
x
2
x
3
x
1


x
1
(
x
1


x
1
)
2
x
2


x
2
(
x
2


x
2
)
2
x
3


x
3
(
x
3


x
3
)
2
x
1

(
m
)
t
a
t
i
o
n
x
3
x
2
(
M
m
3
)
(
m
m
)
J
a
n
.
3
.
6
0
3
0
1
4
.
0
9
0
0
1
9
6
1
0
8
5
0
.
4
4
2
0

0
.
7
1
0
.
5
0
4

6
3
.
3
3
4
0
0
0

2
2
4
8
4
F
e
b
.
4
.
0
5
5
2
2
3
.
4
2
7
0
0
5
5
0
2
1
0
9
4
.
7
1
2
1
7

0
.
2
6
0
.
0
6
8

4
1
.
3
3
1
7
1
0

1
2
.
6
1
6
0
M
a
r
.
4
.
1
2
9
5
3
2
.
4
9
0
3
0
1
0
5
0
3
9
1
1
3
3
.
3
3
0
8
0

0
.
1
3
0
.
0
1
7
1
.
6
7
3

3
.
6
1
3
A
p
r
i
l
4
.
5
7
9
0
5
1
.
2
8
1
0
0
2
6
2
0
4
1
2
2
3
4
4
6
1
0
0
.
2
6
0
.
0
6
8

3
.
3
3
1
1
1
5
.
2
2
3
0
M
a
y
4
.
8
0
2
0
0
6
2
.
3
4
0
0
0
0
3
8
9
0
9
6
0
2
9
9
1
2
4
6
0
0
.
4
9
0
.
2
4
0
1
0
6
.
6
7
1
1
3
7
0
2
6
.
3
7
0
0
J
u
n
e
4
.
9
5
2
8
0
7
9
.
5
7
8
5
0
0
6
3
2
0
1
3
8
7
3
9
4
2
2
2
4
0
0
.
6
4
0
.
4
1
0
1
8
6
.
6
7
3
4
8
0
0
4
3
.
5
1
8
9
0
J
u
l
y
5
.
0
2
1
6
8
6
1
.
4
2
8
3
0
0
3
7
7
8
4
3
3
0
8
1
0
3
0
0
0
.
7
1
0
.
5
0
4
7
4
.
6
7
5
4
9
0
2
5
.
4
6
4
0
A
u
g
.
4
.
8
0
5
1
4
7
.
4
2
6
1
0
2
2
5
2
4
4
2
2
8
2
4
2
0
0
.
4
9
0
.
2
4
0
4
2
.
3
3
1
7
9
7
1
1
.
4
1
3
0
S
e
p
t
.
4
.
4
2
1
8
3
4
.
4
3
2
5
1
1
8
2
7
9
.
5
1
5
2
6
2
0
0
.
1
1
0
.
0
1
2

7
5
.
3
3
5
6
7
0

1
.
6
3
O
c
t
.
4
.
2
0
2
7
1
8
.
9
7
3
0
3
5
8
1
1
3
.
3
7
9
.
5
5
1
0

0
.
1
1
0
.
0
1
2

6
6
.
3
3
4
4
0
0
1
7
.
1
2
9
4
N
o
v
.
3
.
9
0
5
2
1
.
8
2
7
1
3
.
3
2
0
3
7
9
3
.
5

0
.
4
1
0
.
1
6
8

4
1
.
3
3
1
7
1
0

3
4
.
2
1
1
8
0
D
e
c
.
3
.
3
0
5
7
5
.
2
3
2
5
2
7
.
1
1
8
8
1
7
.
2
2
9
6

1
.
0
1
1
.
0
2
0

3
6
.
3
3
1
3
2
0

3
0
.
8
9
5
0

n

=

1
2
5
1
.
7
3
1
1
2
0
4
3
1
.
9
1
7
.
1
5
1
.
6
8
5
1
3
8
.
8
1
9
9
7
.
1
5
.
8
3
3
.
2
6
3
7
2
2
8
1
6
6
7
4


1
0
4


1
0
4


1
0
4
x

=

x
n

,

x
1

=

4
.
3
1
,

x
2

=

9
3
.
3
3
,

x
3

=

3
6
,

(
)
x
x
n

2
1

,

1

=

0
.
5
4
5
,

2

=

8
1
,

3

=

2
4
.
6
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 322
322 HYDROLOGY
and the regression line is given by
x
1
= 4.02 + 0.00865x
2
+ 0.0144x
3
or calling GWT as y (m), precipitation as P (mm) and pumping rate Q (Mm
3
), the linear multiple
regression line is given by
y = 4.02 + 0.00865 P + 0.0144 Q
from which the GWT corresponding to a known precipitation and pumping rate can be computed.
To compute the multiple correlation coefficient r
1.23
r
12
=
x x nx x
n
1 2 1 2
1 2
1

( )
=
5138 8 12 4 31 93 33
12 1 0 545 81
. ( . )( . )
( )( . )

= 0.66
r
13
=
x x nx x
n
1 3 1 3
1 3
1

( )
=
1997 1 12 4 31 36
12 1 0 545 24 6
. ( . )
( )( . ) .

= 0.92
r
23
=
x x nx x
n
2 3 2 3
2 3
1

( )
=
5.83 10 12 (93.33) 36
(12 1) 81(24.6)
4

= 0.82
r
1.23
=
0.66 0.92 2(0.66)(0.92)(0.82)
1 (0.82)
2 2
2
+

= 0.94
r
1.23
= 0.94 indicates a close linear correlation
Also from Eq. (13.17)
r
1.23
= 1 1 0 66 1 0 92
2 2
( . ) ( . ) = 0.95
The standard error of estimate
S
1.23
=
1
1
1
2
r
.23
= 0.545
1 0 94
2
( . )
S
1.23
= 0.2
13.4 COAXIAL GRAPHICAL CORRELATION OF RAINFALL RUNOFF
Kohler and Linsley (1951) showed that the rate at which the soil moisture is depleted from a
catchment is roughly proportional to the amount of storage and the soil moisture decreases
logarithmically with time during periods (days) of no precipitation and
I
t
= I
0
K
t
...(13.20)
where I
0
= initial value of the antecedent precipitation index (API, rainfall depth)
I
t
= reduced value of API t-days later
K = recession factor ranging normally between 0.85 and 0.98
putting t = 1 day in Eq. (13.20), gives
I
t
= I
0
K
i.e., the index for any day is equal to that of the previous day multiplied by the factor K. If rain
occurs on any day, the amount of rain (rather precipitation minus runoff) is added to the
index. Since K is a function of potential evapotranspiration, it should be related to seasons or
calender months. API is a satisfactory concept in estimating of runoff but systematic records of
soil moisture are difficult to obtain for large areas.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 323
LINEAR REGRESSION 323
Example 13.3 The API for a station was 50 mm on 1st July 1995; 40 mm rain fell on 6th July,
25 mm on 8th July and 30 mm on 9th July. Assuming a recession constant of 0.9, compute the
API
(i) on 15th July.
(ii) on 15th July, assuming no rainfall during 1-15 July.
Solution (i) I
t
= I
0
K
t
, I
0
= 50 mm, K = 0.9
W
e
e
k
o
f
y
e
a
r
2
5
3
0
3
5
4
0
2
0
4
5
5
0
1
5
5
2
5
5
1
1
2
.
5
1
0
7
.
5
5
2
.
5
0
1
0
A
P
,
c
m
I
4
1
2
.
5
1
0
7
.
5
(
3
.
2
)
5
2
.
5
0
S
t
o
r
m
r
u
n
o
f
f
(
c
m
)
o
b
s
e
r
v
e
d
Storm runoff (cm) computed
2
S
t
o
r
m
d
u
r
a
t
i
o
n
(
h
r
)
0
2
4
4
8
7
2
9
6 4
2
0
0 (3.6) 2.5 5 7.5 10 12.5
3
S
t
o
r
m
p
p
t
n
.
(
c
m
)
1
5
1
2
.
9
1
0
7
.
5
6
2
.
6
Fig. 13.2 Coaxial correlation for Monocacy river, USA
(US National Weather Service)
R
a
i
n
f
a
l
l
i
n
t
h
e
m
o
n
t
h
1
6
0
8
7
.
5
7
5
6
7
6
2
.
5
5
0
3
7
.
5
2
5
1
2
.
5
2
Runoff (cm) computed
100 75 50 25 0
41.3
1
N
o
.
o
f
t
h
e
m
o
n
t
h
1
0
1
1 1
2
7
6
4
.5
8
0 25 50 75 100
49.5
Rainfall in the pre-
vious month (cm)
3
0
2
5
5
0
7
5
1
0
0 R
u
n
o
f
f
(
c
m
)
o
b
s
e
r
v
e
d
Given:
Rainfall in June = 49.5 cm
in July = 67.0 cm
From graph:
Runoff in July = 41.3 cm
Fig. 13.3 Coaxial correlation for Kallada basin (after NN Pillai, 1964)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 324
324 HYDROLOGY
on 6-July, I
61
= 50 0.9
5
+ 40 = 69.52 mm
on 8-July, I
86
= 69.52 0.9
2
+ 25 = 81.31 mm
on 9-July, I
98
= 81.31 0.9 + 30 = 103.18 mm
on 15-July, I
159
= 103.18 0.9
6
= 54.84 mm = API
(ii) I
151
= 50 0.9
14
= 11.44 mm = API
Depending upon the API, the time of the year, duration and magnitude of the storm and
the altitude, the estimation of runoff can be made by following the data as indicated by the
dotted line on the graphical plot for the Monacacy river, USA (Fig. 13.2). Thus, a catchment
with an API of 2.5 cm, in the 10th week of the year with the occurrence of storm of 24 hr
duration and 12 cm depth of precipitation, will yield a runoff of 3.6 cm. This graphical ap-
proach is called coaxial correlation and is preferred to the multivariate linear correlation since
many complex characteristics of the basin and storm are involved.
Another coaxial graphical correlation for estimating the monthly runoff from a catch-
ment of the river Kallada in south Kerala (south India) as given by Pillai N.N. (1964) is shown
in Fig. 13.3. Here the API has been taken as the precipitation of the previous month and the
runoff for a particular month can be read on the graphical plot if the precipitation in the
previous month is known. Thus, if the surface runoff in the month of July (7th month) is
required, given the rainfalls for the months of June and July as 49.5 cm and 67.0 cm, respec-
tively, then the runoff during the month of July is 41.3 cm, as indicated by the dotted line. If
however, the total yield from the catchment is to be found out, the base flow (estimated as 30
cm) is to be added to the cumulative surface runoff of the whole year.
Though the correlation graph was developed for river Kallada (basin area = 874 km
2
)
during 1952-57, it was also applied to compute the yield of river Pamba (basin area = 1700
km
2
) in 1953 and of river Achenkoil (basin area = 847 km
2
) in 1955 and was found to be within
4% of the observed yield.
Example 13.4 Rainfall (P) and Runoff (R) data for a small catchment are given below:
P (mm): 22 26 14 4 30 12
R (mm): 6 12 4 0 18 6
Develop a linear regression equation and find the coefficient of correlation; write a com-
puter program in C-language.
Solution R = aP + b x = P, y = R, m = no. of data pairs = 6
a =
m xy x y
m x x
. .
. ( )

2 2
...(i), b = (y a x)/m ...(ii)
Correlation coefficient, r =
m xy x y
m x x m y y


.
[ ( ) ] [ ( ) ]
2 2 2 2
...(iii)
x = 108, y = 46, (x)
2
= 11664, (y)
2
= 1116
x
2
= 484 + 676 + 196 + 16 + 900 + 144 = 2416
y
2
= 36 + 144 + 16 + 0 + 324 + 36 = 556
xy = 132 + 312 + 56 + 0 + 540 + 72 = 1112
Substituting these values in (i), (ii) and (iii),
a = 0.6, b = 3.16, r = 0.917 1, Good fit
Regression equation: R = 0.6P = 3.16.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 325
LINEAR REGRESSION 325
C-LANGUAGE CODE to fit a linear regression equation, Example 13.4, Chapter-13
/ * program for a linear fit eqn. R = aP + b */
#include <stdio.h>
#include <math.h>
#include <conio.h>
main ( )
{
Float sumx = 0, sumy = 0, sumxx = 0, sumyy = 0, sumxy = 0;
float x[10], y[10], num, den, dx, dy, a, b, r;
int i, m;
printf (Program LINREG/n);
scanf (%d, &m);/* m = No. of data pairs read */
for (i = 1; i < = m; i + +)
{
scanf (% f% f, & x[i], & y[i]);
sumx + = x[i];
sumy + = y[i];
sumxx + = x[i]* x[i];
sumyy + = y[i]* y[i];
sumxy + = x[i]* y[i];
}
/ * compute the parameters */
num = m * sumxy sumx * sumy;
den = m * sumxx sumx * sumx;
a = num/den;
b = (sumy a * sumx)/m;
dx = m * sumxx sumx * sumx;
dy = m * sumyy sumy * sumy;
r = num/sqrt (dx * dy);
/ * Output */
printf (\n No. of data pairs (x, y) m = % d\n, m);
for (i = 1; i < = m; i + +)
printf ( % 4.1 f , x [i];
printf (\n);
for (i = 1; i < = m; i + +)
printf ( % 4.1 f , y [i]);
printf (\n\n);
printf ( slope a = % 4.2f, intercept b = % 4.2 f\n, a,b);
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD13-1.PM5 326
326 HYDROLOGY
printf (Correlation Coefficient r = % 4.3 f , r);
printf (\n Regression Eqn. is R = % 4.2 f * P + % 4.2 f\n, a, b);
/* End of main * /
Example 3.1
INPUT: 6
22 6
26 12
14 4
4 0
30 18
12 6
OUTPUT: Program LINREG
No. of data pairs (x, y)m = 6
22.0 26.0 14.0 4.0 30.0 12.0
6.0 12.0 4.0 0.0 18.0 6.0
Slope a = 0.60, intercept b = 3.16,
Correlation coefficient r = 0.917
Regression Eqn. is R = 0.60* P 3.16.
PROBLEM8
13.1 On a small area the rainfall-runoff (P-R) observations are given below. Establish an equation
relating them by linear regression. Find the coefficient of correlation. What is the runoff ex-
pected for a rainfall of 20 mm?
P (mm): 22 26 14 4 30 12
R (mm): 6 12 4 0 18 6
[Ans. R = 0.6 P 3.13, r = 0.92; 8.87 mm]
13.2 The observed annual rainfall (P) and the corresponding runoff (R) for a small catchment are:
Year: 1985 1986 1987 1988 1989 1990
P (cm): 90 110 40 130 146 100
R (cm): 30 50 6 62 75 40
Develop a rainfall-runoff regression equation and find the coefficient of correlation. What is the
runoff expected for an annual rainfall of 80 cm? [Ans. R = 0.657 P23.6, r = 0.95; R = 29 cm]
13.3 The rainfall mass curve of a 3 hr storm gave the following results:
Time (hr): 10.00 10.15 10.30 10.45 11.00 11.15 11.30 11.45 12.00 12.15 12.30 12.45 13.00
Depth (mm): 0 9.5 17.0 27.0 40.5 49.0 63.0 84.0 95.0 102 110 112 112
Develop a maximum intensity-duration relation of the form i =
a
t b
n
( ) +
by linear regression.
Ans.
( )
.
i
t
=
+
L
N
M
M
O
Q
P
P
300
12
0 4
Hint: Find the max. intensities at 15-min intervals; use trial values of a.
13.4 For the Stage-Discharge Data of a stream in Example 6.2, develop a relation by linear regres-
sion of the form Q = k(h a)
n
.
Hint: Use trial values of a.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 14
327
STATISTICAL AND PROBABILITY
ANALYSIS OF HYDROLOGICAL DATA
14.1 ELEMENTS OF STATISTICS
1. Population and sample. Observed values of x (variate) for a finite number of years is
known as sample of x. Say annual flood peaks or annual rainfall for 75 years gives the sample;
on the other hand, population consists of the values of annual flood peaks from time immemo-
rial to eternity. The population parameters can be estimated by means of parameters ob-
tained from the sample, known as sample parameters. Each phenomena is characterised by a
certain value, which varies in time and space. This characterisation is called variable and its
particular value is a variate.
If the value of one variate is independent of any other, the variable in question is a
random variable. The hydrological processes are mostly random and hence the respective
variables are equally random. All the time series (as well as other series) may be characterised
by statistical parameters.
2. Central tendency. Three types of parameters are generally used to represent meas-
ures of central tendency.
(a) Expected value. This value of the random variable x is given by
=

z
x f(x) dx ...(14.1)
This population parameter can be estimated by the sample parameters as
(i) Arithmetic mean x =
x
n
...(14.2)
for grouped data x =
fx
n
...(14.2 a)
(ii) Geometric mean x
g
= (x
1
. x
2
. x
3
. ... x
n
)
1/n
...(14.3)
(iii) Harmonic mean x
h
=
n
x

1
...(14.4)
where n = the size of the sample, say the number of years of annual flood peaks.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 328
328 HYDROLOGY
For any set of variates x > x
g
> x
h
In most cases, the arithmetic mean gives the best estimate of the expected value, i.e.,
x .
(b) Median. The value of the variate such that half of the variates are below it and the
other half above it, is called the median of the series, i.e., it is the value of the variate having a
50% cumulative frequency.
(c) Mode. The value of the variate having the highest frequency is called the mode,
Fig. 14.1 (see also Fig. 15.2). For unimodel curves, which are moderately skewed, the empiri-
cal relation is
Mean mode = 3(mean median) ...(14.5)
C
e
n
t
r
e
.
o
f
g
r
a
v
i
t
y
Skewed
curve
Max. frequency
Cumulative
frequency = 50% (See also Fig. 15.2)
x = precipitation
or
flood peak
Area represents
probability of
occurrence of
magnitude x >
Variate x
x
x
median
mean
mode x
x
2
x
1
P
r
o
b
a
b
i
l
i
t
y
d
e
n
s
i
t
y
f
(
x
)
.
o
r
N
o
.
o
f
o
c
c
u
r
r
e
n
c
e
s
Fig. 14.1 Skewed distribution
3. Variability. The measures of variability or dispersion of a probability distribution
curve are given by the following parameters.
(a) Mean deviation. The mean of the absolute deviations of values from their mean is
called mean deviation (MD)
MD =
| | x x
n

...(14.6)
(b) Standard deviation. It is the square root of the mean-squared deviation of the variates
from their mean, and the standard deviation for the population (
p
) is given by

p
=
( ) x
n

2
...(14.7)
and this is estimated from the standard deviation for the sample () given by
=
( ) x x
n

2
1
...(14.8)
=
x x x
n
2
1

...(14.8 a)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 329
STATISTICAL AND PROBABILITY ANALYSIS OF HYDROLOGICAL DATA 329
=

x
x
n
n
2
2
1

( )
...(14.8 b)
=
n
n
x x

1
2 2
( ) ...(14.8 c)
where x
2
=
x
n
2
for grouped data, =
f x x
n
. ( )

2
1
...(14.8 d)
The dispersion about the mean is measured by the standard deviation, which is also
called the root mean square of the departures from the mean, Fig. 14.2.
Area represents (2.14%)
probability (% of time )
x x
3
>
Normal curve (bell - Shaped)
(area under curve = 1)
Shaded area represents
% of time the variate x
> x but < x
1 2
x = precipitation or
flood peak
Mean = x = median
= mode
3s
2s
2.14%
13.6%
s s
13.6%
2s
x
x
1
x
2
x
x
3
x
3
Variate x
P
r
o
b
a
b
i
l
i
t
y
d
e
n
s
i
t
y
f
(
x
)
o
r
N
o
.
o
f
o
c
c
u
r
r
e
n
c
e
s
s = (x x)
n 1
2
n = Sample size
68.26%
0
Fig. 14.2 Normal distribution curve
(c) Variance. The square of the standard deviation is called variance, i.e., given by
p
2
for the population and
2
for the sample.
(d) Range. The range (R) denotes the difference between the largest and smallest values
of the sample and is given by Hurst (1951, 1956) and Klemes (1974) as
R = (n/2)
k
, 0.5 < k < 1 ...(14.9)
= 1.25
p

n
...(14.9 a)
for a random normally distributed time series.
(e) Coefficient of variation. The standard deviation divided by the mean is called the
coefficient of variation (C
v
) and is given by
C
v
=

p
x

...(14.10)
4. Skewness (asymmetry). The lack of symmetry of a distribution is called skewness or
asymmetry. The population skewness () is given
=
( ) x
n

3
...(14.11)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 330
330 HYDROLOGY
This is estimated from the sample skewness (a) given by
a =
( ) x x
n

3
1
...(14.12)
For grouped data a =
f x x
n
( )

3
1
...(14.12 a)
The degree of the skewness of the distribution is usually measured by the coefficient of
skewness (C
s
) and is given by
C
s
=


p
a
3 3
...(14.13)
Another measure of skewness often used in practice is Pearsons skewness (S
k
) given by
S
k
=

mode
p

x mode

...(14.14)
From Eq. (14.5), S
k
=
3( ) x median

...(14.15)
Example 14.1 For the grouped data of the annual floods in the river Ganga at Hardwar
(1885-1971), find the mean, median, and mode. Determine the coefficients of skew and the
coefficient of variation.
Class interval
(1000 cumec) Frequency
0-2* 0
2-4* 17
4-6 27
6-8 18
8-10 18
10-12 3
12-14 0
14-16 2
16-18 1
18-20 1
*from 0 to <2.
from 2 to <4, and like that.
Solution The computations are made in Table 14.1
(i) Mean x = 6.6 tcm
(ii) Standard deviation, = 3.16 tcm
(iii) Median = L
md
+
n CF
f
md
/ 2 F
H
G
I
K
J
CI
= 4 +
87 2 17
27
/ F
H
G
I
K
J 2 = 6 tcm
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 331
STATISTICAL AND PROBABILITY ANALYSIS OF HYDROLOGICAL DATA 331
(iv) Mode = L
mo
+
d
d d
1
1 2
+
F
H
G
I
K
J
CI, see Fig. 15.2
= 4 +
10
10 9 +
F
H
G
I
K
J
2 = 5 tcm
(v) Coefficients of skew (C
s
)
Pearsons first coefficient, C
s1
=
x mode

=
6 6 5
3 16
.
.

= 0.507
Pearson second coefficient, C
s2
=
3( ) x median

=
3 6 6 6
3 16
( . )
.

= 0.57
For flood data (Foster), C
s
=
f x x
n
( )
( )

3
3
1
=
3818.55
(87 1) 3.16
3

= 1.4
Adjustment for the period of record,
C
s(adj)
= C
s
1+
F
H
G
I
K
J
k
n
= 1.4 1
6
87
+
F
H
G
I
K
J
= 1.5
All the coefficients of skew are positive and the skew is to the right; if the coefficients
were negative, the skew would have been to the left.
Table 14.1 Compuations for mean, median and mode. (Example 14.1)
Class interval Mid-point Frequency Product x x (x x )
2
f.(x x )
2
(x x )
3
f.(x x )
3
CI of CI f f.x
(1000 cumec) x
0-2 1 0 0 5.6 31.4 0 176 0
2-4 3 17 51 3.6 13.0 221.0 46.8 796.00
4-6 5 27 135 1.6 2.56 69.2 4.1 110.50
6-8 7 18 126 0.4 0.16 2.9 0.064 1.15
8-10 9 18 162 2.4 5.76 103.8 13.82 249.00
10-12 11 3 33 4.4 19.40 58.2 85.30 255.90
12-14 13 0 0 6.4 41.00 0 262.60 0.00
14-16 15 2 30 8.4 70.50 141.0 593.00 1186.00
16-18 17 1 17 10.4 108.00 108.0 1123.00 1123.00
18-20 19 1 19 12.4 154.00 154.0 1910.00 1910.00
f = n = 87 fx = 573 f(x x )
2
= 858.1 f(x x )
3
= 4725 05
906.50
= 3818.55
Mean x =
fx
n
=
573
87
= 6.6 tcm
Standard deviation, =
f x x
n
( )

2
1
=
858 1
87 1
.

= 3.16 tcm
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 332
332 HYDROLOGY
(vi) Coefficient of variation, C
v
=

x
100
=
316
6 6
.
.
100 = 47.8%
Assignment problem
For the grouped data of the partial duration floods (Q
b
> 4333 cumec) of river Ganga at Hardwar
(1885-1971), find the mean, median and mode. Also determine the coefficient/s of skew and
coefficient of variation.
Class interval Frequency
(1000 cumec) (or no. of occurrences)
4-6* 86
6-8* 56
8-10 22
10-12 6
12-14 1
14-16 2
16-18 1
18-20 1
*from 4 to <6.
from 6 to <8, and like that.
[Hint See Fig. 15.4]
14.2 PROBABILITY OF HYDROLOGIC EVENTS
Since most hydrologic events are represented by continuous random variables, their density
functions denote the probability distribution of the magnitudes. Some of the frequently used
density functions used in hydrologic analysis are given below.
(a) Normal distribution. The density function of normal probability distribution is given
by
f(x) =
1
2
p
exp

F
H
G
I
K
J
( ) x
p

2
2
2
, < x < ...(14.17)
where
p
and are the two parameters, which affect the distribution, Fig. 14.2.
In this distribution, the mean, mode and median are the same and the area under the
curve is unity.
(b) Gamma distribution. The density function of this distribution is given by
f(x) =
x e
a b
a x b
a

+
/
!
1
, for 0 < x < ...(14.18)
= 0, elsewhere
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 333
STATISTICAL AND PROBABILITY ANALYSIS OF HYDROLOGICAL DATA 333
where a and b are the two parameters, which affect the distribution (Fig. 14.3). A change of the
parameter b merely changes the scale of the two axes.
a = 0
a = 1
a = 3
P
r
o
b
a
b
i
l
i
t
y
d
e
n
s
i
t
y
f
(
x
)
Variate x
Fig. 14.3 Gamma distribution
Here = b (a + 1) and
p
2
= b
2
(a + 1)
(c) Poisson distribution. If n is very large and y is very small, such that y . n = m is a
positive number, then the probability density function which is in the Poisson distribution is
given by
y = f (x) =
m e
x
x m

!
Under abnormal skewness, the Poisson distribution is useful. The statistical param-
eters are
p
= and skewness =
1

.
(d) Lognormal distribution. A random variable x (variate) is said to be in log-normal
distribution if the logarithmic values of x is distributed normally. The density function in this
distribution is given by
f(x) =
1
2
y
exp

F
H
G
I
K
J
( ) y
y
y

2
2
...(14.20)
where y = ln x, x = variate,
y
= mean of y,
y
= standard deviation of y. This is a skew distribu-
tion of unlimited range in both directions. Chow has derived the statistical parameters for x as
= exp (
y
+
y
2
/2), = exp
y
2
1 ...(14.21)
C
v
= exp
y
2
1 , C
s
= 3C
v
+ C
v
3
(e) Extremal distribution This is the distribution of the n extreme values (largest or the
smallest), each value being selected out of p values contained in each of n samples, which
approaches an asymptotic limit as p is increased indefinitely. Depending on the initial distri-
bution of the n.p values, three asymptotic (types) extremal distributions can be derived.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 334
334 HYDROLOGY
(i) Type-I distribution In this distribution, the density function is given by
f(x) =
1
c
exp
+ F
H
G
I
K
J
+ F
H
G
I
K
J
L
N
M
O
Q
P
a x
c
a x
c
exp , < x < ...(14.22)
where x is the variate and a, c are the parameters. By the method of moments the parameters
have been evaluated as
a = c , c =
6

...(14.23)
where = 0.57721 ... Eulers constant. The distribution has a constant C
s
= 1.139. The Gumbel
distribution used in flood frequency analysis is an example of this type.
(ii) Type-II distribution In this type, the cumulative probability is given
F(x) = exp [ (/x)
k
], < x < ...(14.24)
where and k are the parameters.
(iii) Type-III distribution. In this type, the cumulative probability is given by
F(x) = exp



F
H
G
I
K
J
L
N
M
M
O
Q
P
P
x
k

, < x ...(14.25)
where and k are the parameters. Weibull distribution used in draught-frequency analy-
sis is an example of this type.
(f ) Pearsons Type-III distribution This is a skew distribution with limited range in the
left direction, usually bell shaped. The Pearson curve (Fig. 14.4), is truncated on one side of the
axis of the variate, i.e., below a certain value of the variate the probability is zero, but it is
infinite converging asymptotically to the axis of the variate. This means even values infinitely
large (or small) have a certain probability of occurrence.
c.g.
F
r
e
q
u
e
n
c
y
,
(
f
)
median
mode arith-mean
Variate (x)
0
Fig. 14.4 Pearsons Type-III distribution
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 335
STATISTICAL AND PROBABILITY ANALYSIS OF HYDROLOGICAL DATA 335
(g) Logarithmic Pearson Type-III distribution. This distribution has the advantage of
providing a skew adjustment. If the skew is zero, the Log-Pearson distribution is identical to
the log-normal distribution.
The probability density function for type III (with origin at the mode) is
f(x) = f
0
1
F
H
G
I
K
J
x
a
c
exp ( cx/2) ...(14.26)
where c =
4

1, a =
c
2
3
2

, =

3
2
2
2
...(14.26 a)
f
0
=
n
a
c
e c
c
c
+
+
1
1 ( )
...(14.26 b)

2
= the variance,

3
= third moment about the mean =
6
g
e = the base of the napierian logarithms
= the gamma function
n = the number of years of record
g = the skew coefficient
= the standard deviation
The US Water Resources Council (1967) adopted the Log-Pearson Type-III distribution
(to achieve standardisation of procedures) for use by federal agencies. The procedure is to
convert the data series to logarithms and compute.
Mean: log x =
log x
n
...(14.27)
Standard deviation:
log x
=
(log log ) x x
n

2
1
...(14.27 a)
Skew coefficient: g =
n x x
n n
x
(log log )
( )( )( )
log


3
3
1 2
...(14.27 b)
The values of x for various recurrence intervals are computed from
log x = log x + K
log x
...(14.28)
and the frequency factor K is obtained from Table 14.2 for the computed value of g and the
desired recurrence interval (see Example 15.1).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD14-1.PM5 336
336 HYDROLOGY
Table 14.2. K-Values for the Log-Pearson Type-III Distribution
Skew Recurrence interval (T-yr)
coefficient 2 5 10 25 50 100 200
(g) Per cent chance (annual probability of occurrence P(%))
50 20 10 4 2 1 0.5
3.5 0.396 0.420 1.180 2.278 3.152 4.051 4.970
2.5 0.360 0.518 1.250 2.162 3.048 3.845 4.652
2.0 0.307 0.609 1.302 2.219 2.912 3.605 4.298
1.8 0.282 0.643 1.318 2.193 2.848 3.499 4.147
1.6 0.254 0.675 1.329 2.163 2.780 3.388 3.990
1.4 0.225 0.705 1.337 2.128 2.706 3.271 3.828
1.2 0.195 0.732 1.340 2.087 2.626 3.149 3.661
1.0 0.164 0.758 1.340 2.043 2.542 3.022 3.489
0.9 0.148 0.769 1.339 2.018 2.498 2.957 3.401
0.8 0.132 0.780 1.336 1.993 2.453 2.891 3.312
0.7 0.116 0.790 1.333 1.967 2.407 2.824 3.223
0.6 0.099 0.800 1.328 1.939 2.359 2.755 3.132
0.5 0.083 0.808 1.323 1.910 2.311 2.686 3.041
0.4 0.066 0.816 1.317 1.880 2.261 2.615 2.949
0.3 0.050 0.823 1.309 1.849 2.211 2.544 2.856
0.2 0.033 0.830 1.301 1.818 2.159 2.472 2.763
0.1 0.017 0.836 1.292 1.785 2.107 2.400 2.670
0 0.000 0.841 1.282 1.751 2.054 2.326 2.576
0.1 0.017 0.846 1.270 1.716 2.000 2.252 2.482
0.2 0.033 0.850 1.258 1.680 1.945 2.178 2.388
0.3 0.050 0.853 1.245 1.643 1.890 2.104 2.294
0.4 0.066 0.855 1.231 1.606 1.834 2.029 2.201
0.5 0.083 0.860 1.216 1.567 1.777 1.955 2.108
0.6 0.099 0.857 1.200 1.528 1.720 1.880 2.016
0.7 0.115 0.857 1.183 1.488 1.663 1.806 1.926
0.8 0.132 0.856 1.166 1.448 1.606 1.733 1.837
0.9 0.148 0.854 1.147 1.407 1.549 1.660 1.749
1.0 0.164 0.852 1.128 1.366 1.492 1.588 1.664
1.2 0.195 0.843 1.086 1.282 1.379 1.449 1.501
1.4 0.225 0.832 1.041 1.198 1.270 1.318 1.351
1.6 0.254 0.817 0.994 1.116 1.166 1.197 1.216
1.8 0.282 0.799 0.945 1.035 1.069 1.087 1.097
2.0 0.307 0.777 0.895 0.959 0.980 0.990 0.995
2.5 0.360 0.710 0.771 0.793 0.798 0.799 0.800
3.0 0.396 0.636 0.660 0.666 0.666 0.667 0.667
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 15
337
FLOOD FREQUENCYPROBABILITY
AND STOCHASTIC METHODS
15.1 FLOOD FREQUENCY METHODS
For the annual flood data of Lower Tapti River at Ukai (30 years: 19391968) in Example 8.5
the flood frequencies of 2, 10, 50, 100, 200, and 1000-year floods have been worked out
below by the probability methods developed by Fuller, Gumbel, Powell, Ven Te Chow, and
stochastic methods, and the flood frequency curves are drawn on a semi-log paper as shown in
Fig. 15.1. It can be seen that the Gumbels method gives the prediction of floods of a particular
frequency exceeding the observed floods by a safe margin and can be adopted in the design of
the structure.
1. Fullers formula. Q
T
= Q (1 + 0.8 log T) ...(15.1)
From Table 8.5, Q = 14.21 thousand cumec (tcm)
T log T 0.8 log T Q
T
= Q (1 + 0.8 log T)
(tcm)
1000 3.0 2.4 48.3
200 2.3010 1.8408 40.4
100 2.0 1.6 37.0
50 1.6990 1.3592 33.5
10 1.0 0.8 25.6
2 0.3010 0.2408 17.35
2. Gumbels method. According to the extreme value distribution, the probability of occur-
rence of a flood peak Q, is given by
P = 1 e
e
y

...(15.2)
the reduced variate y is given by
y = 0.834 2.303 log log
T
T 1
or, y = 0.834 2.303 X
T
...(15.3)
where X
T
= log log
T
T 1
...(15.3 a)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 338
338 HYDROLOGY
The reduced variate y is linear with the variate Q (annual flood peak) itself and is given
by
y =
n

Q Q
F
H
G
I
K
J

+ y
n
...(15.4)
where
n
(reduced standard deviation) and y
n
[reduced mean (to mode)] are functions of the
sample size n and are given in Table 15.1.
Q
T
= Q +
y y
n
n
F
H
G
I
K
J

...(15.5)
or Q
T
= Q + K ...(15.6)
where the frequency factor K =
y y
n
n

and Q
T
= annual flood peak, which has a recurrence
interval T.
Since the coefficient of variation C
v
= /
Q
Q
T
=
Q
(1 + KC
v
) ...(15.7)
The frequency factor K for the sample size n and the desired recurrence interval T can
be directly read from Table 15.2.
There are two approaches to the solution by the Gumbels method. The first approach is,
for a given annual flood peak (Q
T
), to find its recurrence interval T and probability of occur-
rence P, for which the following sequence of tabulation should follow:
Table 15.1 Reduced mean ( y
n
) and reduced standard deviation (
n
)
as functions of sample size n
Size of sample n y
n

n
10 0.4952 0.2457
15 0.5128 1.0206
20 0.5236 0.0628
25 0.5309 1.6915
30 0.5362 1.1124
35 0.5403 1.1283
40 0.5436 1.1413
45 0.5436 1.1518
50 0.5465 1.1607
55 0.5504 1.1681
60 0.5521 1.1747
65 0.5536 1.1803
70 0.5548 1.1854
75 0.5549 1.1898
(Contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 339
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 339
80 0.5569 1.1938
85 0.5578 1.1973
90 0.5539 1.2007
95 0.5553 1.2038
100 0.5600 1.2065
200 0.5672 1.2359
500 0.5724 1.2588
1000 0.5745 1.2685
Q
T
y X
T
T P =
1
T
100
from Eq. (15.4) from Eq. (15.3) from Eq. (15.3 a) (%)
The second approach is, for a given recurrence interval T, to find the annual flood peak
Q
T
(which will be equalled or exceeded), for which the following sequence of tabulation should
follow; the computations are made for Lower Tapti river at Ukai.
X
T
= y = 0.834 K* =
y y
n
n

Q
T
= Q + K P =
1
T
100
T (yr) log log
T
T 1
F
H
G
I
K
J
2.3 X
T
(tcm) %
1000 3.361 6.907 5.67 69.21 0.1
200 2.662 5.295 4.23 55.51 0.5
100 2.360 4.600 3.61 49.21 1.0
50 2.056 3.901 3.02 43.51 2.0
10 1.339 2.250 1.52 28.96 10
2 0.521 0.366 0.14 12.85 50
*(i) for the sample size n = 30, y
n
= 0.5362,
n
= 1.1124.
(ii) for the desired T and the number of years of record n, the value of K can be directly
read from Table 15.2.
Q = 14.21 tcm, = 9.7 tcm
Gumbels method can be viewed as a modification of the earlier probability methods
given by Eqs. (8.11, a and b) as
T =
n
m c + 1
...(15.8)
where c = Gumbels correction, and depends upon the ratio m/n, as given below:
m/n: 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.08 0.04
c: 1 0.95 0.88 0.845 0.78 0.73 0.66 0.59 0.52 0.4 0.38 0.28
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 340
340 HYDROLOGY
Y
e
a
r
s

o
f
R
e
c
u
r
r
e
n
c
e

i
n
t
e
r
v
a
l

(
T

y
r
)
r
e
c
o
r
d

(
n
)
2
5
1
0
1
5
2
0
2
5
3
0
5
0
6
0
7
5
1
0
0
2
0
0
4
0
0
1
0
0
0
1
5
0
.
9
6
7
1
.
7
0
3
2
.
1
1
7
2
.
4
1
0
2
.
6
3
2
2
.
8
2
3
3
.
3
2
1
3
.
5
0
1
3
.
7
2
1
4
.
0
0
5
6
.
2
6
5
2
0

0
.
1
4
7
0
.
9
1
9
1
.
6
2
5
2
.
0
2
3
2
.
3
0
2
2
.
5
1
7
2
.
6
9
0
3
.
1
7
9
3
.
3
5
2
3
.
5
6
3
3
.
8
3
6
4
.
4
9
5
.
1
5
6
.
0
0
6
2
5
0
.
8
8
8
1
.
5
7
5
1
.
9
6
3
2
.
2
3
5
2
.
4
4
4
2
.
6
1
4
3
.
0
8
8
3
.
2
5
7
3
.
4
6
3
3
.
7
2
9
5
.
8
4
8
3
0

1
.
1
5
2
0
.
8
6
6
1
.
5
4
1
1
.
9
2
2
2
.
1
8
8
2
.
3
9
3
2
.
5
6
0
3
.
0
2
6
3
.
1
9
1
3
.
3
9
3
3
.
6
5
3
4
.
2
8
4
.
9
1
5
.
7
2
7
3
5
0
.
8
5
1
1
.
5
1
6
1
.
8
9
1
2
.
1
5
2
2
.
3
5
4
2
.
5
2
0
2
.
9
7
9
3
.
1
4
2
3
.
3
4
1
3
.
5
9
8
4
0

0
.
1
5
5
0
.
8
3
8
1
.
4
9
5
1
.
8
6
6
2
.
1
2
6
2
.
3
2
6
2
.
4
8
9
2
.
9
4
3
3
.
1
0
4
3
.
3
0
1
3
.
5
5
4
4
.
1
6
4
.
7
8
5
.
5
7
6
4
5
0
.
8
2
9
1
.
4
7
8
1
.
8
4
7
2
.
1
0
4
2
.
3
0
3
2
.
4
6
4
2
.
9
1
3
3
.
0
7
8
3
.
2
6
8
3
.
5
2
0
5
0

0
.
1
5
6
0
.
8
2
0
1
.
4
6
6
1
.
8
3
1
2
.
0
8
6
2
.
2
8
3
2
.
4
4
3
2
.
8
8
9
3
.
0
4
8
3
.
2
4
1
3
.
4
9
1
4
.
0
8
4
.
5
6
5
.
4
7
8
5
5
0
.
8
1
3
1
.
4
5
5
1
.
8
1
8
2
.
0
7
1
2
.
2
6
7
2
.
4
2
6
2
.
8
6
9
2
.
0
2
7
3
.
2
1
9
3
.
4
6
7
6
0
0
.
8
0
7
1
.
4
4
6
1
.
8
0
6
2
.
0
5
9
2
.
2
5
3
2
.
4
1
1
2
.
8
5
2
3
.
0
0
8
3
.
2
0
0
3
.
4
4
6
6
5
0
.
8
0
1
1
.
4
3
7
1
.
7
9
6
2
.
0
4
8
2
.
2
4
1
2
.
3
9
8
2
.
8
3
7
2
.
9
9
2
3
.
1
8
3
3
.
4
2
9
7
0
0
.
7
9
7
1
.
4
3
0
1
.
7
8
8
2
.
0
3
8
2
.
2
3
0
2
.
3
8
7
2
.
8
2
4
2
.
9
7
9
3
.
1
6
9
3
.
4
1
3
5
.
3
5
9
7
5
0
.
7
9
2
1
.
4
2
3
1
.
7
8
0
2
.
0
2
9
2
.
2
2
0
2
.
3
7
7
2
.
8
1
2
2
.
9
6
7
3
.
1
5
5
3
.
4
0
0
8
0
0
.
7
8
8
1
.
4
1
7
1
.
7
7
3
2
.
0
2
0
2
.
2
1
2
2
.
3
6
8
2
.
8
0
2
2
.
9
5
6
3
.
1
4
5
3
.
3
8
7
8
5
0
.
7
8
5
1
.
4
1
3
1
.
7
6
7
2
.
0
1
3
2
.
2
0
5
2
.
3
6
1
2
.
7
9
3
2
.
9
4
6
3
.
1
3
5
3
.
3
7
6
9
0
0
.
7
8
2
1
.
4
0
9
1
.
7
6
2
2
.
0
0
7
2
.
1
9
8
2
.
3
5
3
2
.
7
8
5
2
.
9
3
8
3
.
1
2
5
2
.
3
6
7
9
5
0
.
7
8
0
1
.
4
0
5
1
.
7
5
7
2
.
0
0
2
2
.
1
9
3
2
.
3
4
7
2
.
7
7
7
2
.
9
3
0
3
.
1
1
6
3
.
3
5
7
1
0
0

0
.
1
6
0
0
.
7
7
9
1
.
4
0
1
1
.
7
5
2
1
.
9
9
8
2
.
1
8
7
2
.
3
4
1
2
.
7
7
0
2
.
9
2
2
3
.
1
0
9
3
.
3
4
9
3
.
9
3
4
.
5
1
5
.
2
6
1
T
a
b
l
e

1
5
.
2

F
r
e
q
u
e
n
c
y

f
a
c
t
o
r

(
K
)

f
o
r

G
u
m
b
e
l

s

m
e
t
h
o
d
.

(
e
x
t
r
e
m
a
l

v
a
l
u
e
:

T
y
p
e
-
I

d
i
s
t
r
i
b
u
t
i
o
n
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 341
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 341
3. Powell method. A modification in the value of K in Eq. (15.6) was made by R.W. Powell
(1943)
K =
6

L
N
M
O
Q
P
ln ln
T
T 1
...(15.9)
where = Eulers constant = 0.5772 ....
ln = log
e
Simplifying, K = 1.1 1.795 X
T
...(15.10)
Then Q
T
=
Q
+ K ...(15.11)
The computations are made for lower Tapi river at Ukai as per Powell method, below:
X
T
= K = 1.1
T log log
T
T 1
F
H
G
I
K
J
1.795 X
T
K Q
T
= Q + K P =
1
T
100
(yr) (tcm) (%)
1000 3.361 4.93 47.8 62.01 0.1
200 2.662 3.68 35.8 50.01 0.5
100 2.360 3.13 30.4 44.61 1.0
50 2.056 2.58 25.0 39.21 2.0
10 1.339 1.30 12.6 26.81 10
2 0.521 0.164 1.6 12.62 50
*Q = 14.21 tcm, = 9.7 tcm
4. Ven Te Chow method. Another modification of the Gumbels method was made by V.T.
Chow by using the frequency factor. The equation is
Q
T
= a + bX
T
...(15.12)
where X
T
= log log
1
T
T
F
H
G
I
K
J
...(15.12 a)
a, b = parameters estimated by the method of moments from the observed data. The following
equations are derived from the method of least squares.
Q = an + b X
T
(QX
T
) = a X
T
+ b (X
T
2
) ...(15.13)
from which a and b can be solved.
In this method, a plotting position has been assigned for each value of Q when arranged
in the descending order or magnitude of flood peaks. For example, if an annual flood peak Q
T
has a rank m, its plotting position
T =
n
m
+ 1
...(15.14)
From Eq. (15.12 a),
X
T
= log log
1
T
T
F
H
G
I
K
J
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 342
342 HYDROLOGY
putting the value of T from Eq. (15.14)
X
T
= log log
n
n m
+
+
F
H
G
I
K
J
1
1
...(15.15)
The computation is made in Table 15.3 for Lower Tapi river at Ukai.
Table 15.3 Computation for determining a, b: Ven Te Chow method
Order no. Flood peak X
T
= log log
n 1
n 1 m
+
+
F
H
G
I
K
J
QX
T
X
T
2
(m) Q (tcm)
1 42.45 1.848 78.4 3.41
2 37.30 1.538 57.4 2.37
3 29.30 1.468 43.0 2.15
4 24.20 1.223 29.6 1.50
5 22.62 1.119 25.3 1.25
6 21.24 1.032 21.9 1.06
7 20.86 0.965 20.1 0.93
8 19.65 0.886 17.4 0.79
9 18.70 0.830 15.5 0.69
10 18.30 0.794 14.5 0.63
11 14.57 0.718 10.5 0.52
12 14.00 0.672 9.4 0.45
13 12.88 0.627 8.1 0.39
14 12.45 0.585 7.3 0.34
15 11.43 0.542 6.2 0.29
16 10.34 0.502 4.9 0.25
17 9.72 0.462 4.5 0.21
18 9.68 0.434 4.2 0.19
19 8.50 0.386 3.3 0.15
20 8.44 0.347 2.9 0.12
21 7.65 0.308 2.4 0.09
22 7.27 0.270 2.0 0.07
23 7.22 0.230 1.7 0.05
24 6.48 0.190 1.2 0.04
25 6.23 0.146 0.9 0.02
26 6.09 0.102 0.6 0.01
27 5.81 0.051 0.3 0.03
28 4.82 0.006 0.03 0.000036
29 4.39 0.077 0.34 0.0059
30 3.68 0.174 0.64 0.0303
n = 30 426.27 16.00 392.30 18.04
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 343
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 343
0
0
0
0
0
0
Q
=
3
.
6
8
+
2
4
.
2
6
L
o
g
T
:
S
t
o
c
h
a
s
t
i
c
T
Q
=
1
4
.
2
1
+
9
.
7
(
)
:
G
u
m
b
e
l
T
y

0
.
5
4
1
.
1
1
2
4
Q
=
4
.
9
4

:
1
7
.
4
lo
g
(
lo
g
)
:
V
.
T
.
C
h
o
w
T
Q
=
1
4
.
2
1
+
9
.
7
(

1
.
1

1
.
7
9
5
lo
g
(
lo
g
)
)
T
T
T

1
T
T

1
Q
=
1
4
.2
1
(1
+
0
.8
lo
g
T
)
:
F
u
lle
r
T
9
3
-
y
r
o
b
s
e
r
v
e
d
flo
o
d
F
o
s
te
r
:
Q
=
1
4
.2
1
+
9
.7
K
I
T
u
n
s
a
fe
Foster-type
Q = 14.21 + 9.7 K [Ex. 8.5 (b)]
I
T
p
o
w
e
ll
1968 flood
42.5 tcm
1959 flood
37.3 bcm
II
I High flood peaks
during 1876-1968:
93-years
Flood frequency
lines
Annual flood data of
lower Tapi river
at Ukai: 1939-1968
(Western India)
Semi-log paper
P = 100 % of time 90
80
70
60
50
40
30
20
10
100 50 25 10 5 2 1 0.5 0.2 0.1
Probability or % chance of a flood > Q in any one year
T
F
l
o
o
d
p
e
a
k
Q
(
1
0
0
0
c
u
m
e
c
)
T
2 3 4 5 6 8 20 30 50 70 90 200 500 2 3
1000 100 10
Recurrence interval (T-yr)
1
Safe
Fig. 15.1 Flood frequency curves of lower Tapi at Ukai (1939-1968)
Substituting the values in Eq. (15.13)
426.27 = 30a 16b
392.30 = 16a + 18.04b
Solving the equations
a = 4.94, b = 17.4
Then Q
T
= a + bX
T
Q
T
= 4.94 17.4 X
T
...(15.16)
The computations are made for Lower Tapi river at Ukai as per Ven Te Cow method,
below.
T X
T
= Q
T
=
(yr) log log
T
T 1
F
H
G
I
K
J
4.94 17.4 X
t
P =
1
T
100
(tcm) (%)
1000 3.361 63.44 0.1
200 2.662 51.34 0.5
100 2.360 46.04 1
50 2.056 40.64 2
10 1.339 28.29 10
2 0.521 14.02 50
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 344
344 HYDROLOGY
15.2 STOCHASTIC METHOD
Anual Floods: The methods described earlier were either probabilistic or deterministic, and
did not consider the element of time which is possible only by the stochastic approach. Work in
the field of stochastic hydrology has been introduced in USA by Yevdjevich, Ven Te Chow and
others. One of the well known equations based on annual flood data using Poisson probability
law and theory of sums of random number of random variables is
Q
T
= Q
min
+ 2.3 (Q Q
min
) log
n
n
T
f
.
F
H
G
I
K
J
...(15.17)
where T =
n
m
n
f
= number of recorded floods, counting only one for the same flood peak occuring in
different years.
Computations are made by using Eq. (15.17) for the lower Tapti river at Ukai, below.
Here n
f
= n = 30,
Q
= 14.21 tcm, Q
min
= 3.68 tcm
Q
T
= 3.68 + 2.3 (14.21 3.68) log
30
30
. T
F
H
G
I
K
J
or, Q
T
= 3.68 + 24.26 log T ...(15.18)
T log T 24.26 log T Q
T
=
(yr) 3.68 + 24.26 log T
(tcm)
1000 3.0 72.78 76.46
200 2.3010 56.00 59.68
100 2.0 48.52 52.20
50 1.6990 41.25 44.93
10 1.0 24.26 27.94
2 0.3010 7.32 11.00
The highest annual flood peak attained in the lower Tapti river during 1876-1968
(93 years) was 42.5 tcm. From Fig. 15.1, the 100-yr flood given by Gumbels method is 49.21
tcm, 44.61 tcm by Powells, 45.46 tcm by Fosters-Type I [Ex. 8.5 (b)] 46.04 tcm by Chows and
52.20 tcm by stochastic method. The Fullers method gives 37.0 tcm, which is exceeded. Hence
the Gumbels method gives the most probable maximum flood in the life period of structure
and can be adopted as Standard Project Flood (SPF) for the design of the structure, while the
stochastic method seems to predict to some extent the Maximum Probable Flood (MPF). Actu-
ally the SPF and MPF recommended by CWPC, India for the design of Ukai dam, were 48.2
tcm and 59.8 tcm, respectively. The peak of the flood hydrograph obtained by the application
of the 6-hr design unit hydrograph in Example 8.4 was also 59.8 tcm.
15.3 STOCHASTIC MODELLING BY THE PARTIAL DURATION SERIES
Sharma et al. (1975) gave a new model using the partial duration series, i.e., flood peaks above
a given base level (Q
b
), to derive the distribution of the largest floods (peak flows) in a given
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 345
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 345
time interval (0, t). The magnitude of these peaks are considered as a series of random vari-
ables. The base flow Q
b
may be taken as the bankfull discharge of the river at the particular
station. If Q
i
is the flood peak, which has occurred in the time interval (0, t), then the flood
exceedance x
i
in this interval is
x
i
= Q
i
Q
b
...(15.19)
The number n(t) of flood exceedances in an interval of time (0, t) as well as the magnitudes
of the exceedances x(t), are time, dependent-random variables. The time T
i
of ocurrence of
these exceedances are also random variables. The time T
i
is assoiated with the random vari-
ables x
i
for i = 1, 2, 3, ... n.
Todorovic and Emir Zelenhasic (1970) have developed the distribution function F
t
(x) of
the largest exceedance in a given interval of time (0, t) as
F
t
(x) = exp ( t e
x
) ...(15.20)
and the probability of occurrence of exceedances x
i
during the interval (0, t) as
H(x) = 1 exp ( x) ...(15.21)
For a particular exceedance x
T
for an interval of T years
F(x
T
) = exp [ T e
x
T

] ...(15.22)
where and are constants for a particular series of data ( = average number of exceedances
per year).
If x
T
0 for T 0, then F(x
T
) will represent the probability of occurrence of an exceedance
x
T
and
F(x
T
) =
1
T
...(15.23)
From eqs. (15.22) and (15.23), the new mathematical model is obtained as
x
T
=
1

[ln (.T) ln {ln (.T)}] ...(15.24)


Then, the design flood Q
T
may be obtained as
Q
T
= Q
b
+ x
T
...(15.25)
Example 15.1 Flood data in the form of Partial-Duration Series and Annual-Flood Peaks for
the Ganga river at Hardwar for a period of 87 years (1885-1971) are given in Tables 15.4 and
15.5, respectively. The base flow for the partial duration series may be taken as 4333 cumec
(which was accepted as the bankfull discharge in the design of weir at Bhimgoda).
Derive the flood-frequency curves based on the two series by using the stochastic models.
Make a comparative study with the other methods based on annual floods discussed earlier.
[Note Partial duration series data for the Lower Tapti river at Ukai could not be ob-
tained and hence flood data for the Ganga river is given here].
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 346
346 HYDROLOGY
S
t
.

n
o
.
Y
e
a
r
C
u
m
e
c
J
u
n
e
D
t
.
J
u
l
y
D
t
.
A
u
g
.
D
t
.
S
e
p
t
.
D
t
.
O
c
t
.
D
t
.
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
1
.
1
8
8
5
Q
5
8
1
4
1
6
7
2
4
1
9
x
1
4
8
1
2
9
0
8
2
.
1
8
8
6
Q
4
6
6
5
1
5
9
1
6
3
5
6
0
1
8
2
x
3
3
2
4
8
3
1
1
6
8
5
Q
4
8
4
8
2
2
x
5
1
5
Q
4
3
6
9
2
7
x
3
6
3
.
1
8
8
7
Q
5
8
8
2
2
x
1
5
4
9
Q
7
4
0
7
2
2
x
3
0
7
4
4
.
1
8
8
8
Q
5
4
1
7
2
2
4
8
4
8
2
5
4
1
7
3
x
1
0
8
4
5
1
5
1
0
8
4
Q
5
0
3
4
2
7
6
8
7
0
2
0
x
7
0
1
2
5
3
7
Q
4
9
0
9
3
1
x
5
7
6
5
.
1
8
8
9
Q
5
6
8
0
2
5
7
9
3
6
7
7
5
4
6
3
4
9
7
1
9
x
1
3
4
7
3
6
0
3
3
2
1
3
6
3
8
Q
4
8
4
8
1
7
9
8
5
5
1
5
x
5
1
5
5
5
2
2
Q
8
8
2
7
2
9
7
8
5
7
2
9
x
4
4
9
4
3
5
2
4
T
a
b
l
e

1
5
.
4
.

P
a
r
t
i
a
l

d
u
r
a
t
i
o
n

s
e
r
i
e
s

o
f

f
l
o
o
d
s

f
o
r

t
h
e

r
i
v
e
r

G
a
n
g
a

a
t

H
a
r
d
w
a
r

d
u
r
i
n
g

1
8
8
5
-
1
9
7
1

(
8
7

y
e
a
r
s
)
.
B
a
s
e

f
l
o
w
,

Q
b

=

4
3
3
3

c
u
m
e
c
,

Q

=

F
l
o
o
d

p
e
a
k
,

x

=

F
l
o
o
d

p
e
a
k

e
x
c
e
e
d
a
n
c
e
.

(
E
x
a
m
p
l
e

1
5
.
1
)
.
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 347
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 347
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
6
.
1
8
9
0
Q
5
8
1
4
1
9
x
1
4
8
1
Q
1
1
8
8
7
3
0
6
5
0
8
7
x
7
5
5
4
2
1
7
5
Q
9
2
4
9
1
9
x
4
9
1
6
Q
5
4
1
7
3
1
x
1
0
8
4
7
.
1
8
9
1
Q
4
7
8
6
2
6
8
8
2
7
1
4
x
4
5
3
4
4
9
4
8
.
1
8
9
2
Q
4
6
0
5
2
6
5
7
4
7
1
5
4
9
7
1
3
x
2
7
2
1
4
1
4
6
0
8
Q
7
5
4
6
2
5
x
3
2
1
3
9
.
1
8
9
3
Q
5
2
8
7
2
9
5
4
8
2
2
6
6
0
8
7
4
8
4
9
8
5
5
1
2
8
1
9
x
9
5
5
1
1
4
9
1
7
5
4
4
1
6
5
7
9
5
Q
6
8
7
0
1
0
x
2
5
3
7
1
0
.
1
8
9
4
Q
5
1
6
0
8
1
0
0
3
2
6
7
3
7
6
6
x
8
2
7
5
6
9
9
3
0
4
3
Q
6
0
1
8
2
1
9
6
8
0
1
2
x
1
6
8
5
5
3
4
7
Q
9
7
6
7
2
7
1
6
7
5
7
2
6
x
5
4
3
4
1
2
4
2
4
Q
1
3
1
7
9
3
0
x
8
8
4
6
1
1
.
1
8
9
5
Q
5
7
4
7
2
9
6
8
0
1
3
5
0
3
4
8
x
1
4
1
4
5
3
4
7
7
0
1
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 348
348 HYDROLOGY
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
1
2
1
8
9
6
Q
1
4
3
3
6
1
0
x
1
0
0
0
3
1
3
.
1
8
9
7
Q
7
6
2
3
2
2
7
4
0
7
5
4
4
2
7
3
x
3
2
9
0
3
0
7
4
9
4
Q
8
1
7
4
2
3
x
3
8
4
1
1
4
.
1
8
9
8
Q
5
8
1
4
1
0
8
9
5
3
1
2
6
3
6
6
7
x
1
4
8
1
4
6
2
0
2
0
3
3
Q
5
8
8
2
2
4
7
2
4
1
1
8
x
1
5
4
9
2
9
0
8
1
5
.
1
8
9
9
Q
7
5
4
6
2
3
x
3
2
1
3
1
6
.
1
9
0
0
Q
4
4
8
6
1
7
6
6
5
1
1
1
5
9
5
0
6
x
1
5
3
2
3
1
8
1
6
1
7
Q
5
0
9
7
2
6
4
7
8
6
1
2
x
7
6
4
4
5
3
1
7
.
1
9
0
1
Q
4
4
2
7
1
9
7
7
0
0
8
x
9
4
3
3
6
7
Q
1
1
4
0
9
2
4
x
7
0
7
6
1
8
.
1
9
0
2
Q
9
1
6
3
3
4
8
4
8
1
4
x
4
8
3
0
5
1
5
1
9
.
1
9
0
3
Q
7
4
0
7
1
4
x
3
0
7
4
Q
6
2
9
6
2
7
x
1
9
6
3
2
0
.
1
9
0
4
Q
8
5
7
9
2
9
7
0
9
2
3
x
4
2
4
6
2
7
5
9
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 349
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 349
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
Q
7
0
9
1
1
2
x
2
7
5
8
Q
7
0
1
7
2
1
x
2
6
8
4
2
1
.
1
9
0
5
Q
9
3
6
2
1
3
x
5
0
2
9
2
2
.
1
9
0
6
Q
7
0
9
2
2
8
6
8
7
0
3
6
2
2
6
1
6
x
2
7
5
9
2
5
3
7
1
8
9
3
Q
5
9
5
0
1
9
x
1
6
1
7
2
3
.
1
9
0
7
Q
7
5
4
6
3
0
7
2
4
1
3
x
3
2
1
3
2
9
0
8
2
4
.
1
9
0
8
Q
6
6
5
1
1
3
1
1
5
0
4
2
x
2
3
1
8
7
1
7
1
Q
5
9
4
9
2
1
x
1
6
1
6
Q
6
0
1
8
2
9
x
1
6
8
5
2
5
.
1
9
0
9
Q
6
8
7
0
1
6
7
4
0
7
1
2
x
2
5
3
7
3
0
7
4
Q
8
3
3
5
2
1
6
7
2
4
2
0
x
4
0
0
2
2
3
9
1
Q
5
9
4
9
2
7
x
1
6
1
6
2
6
.
1
9
1
0
Q
4
6
0
5
1
5
1
0
1
2
1
2
8
7
4
6
9
3
6
1
5
6
1
1
1
5
0
7
7
3
x
2
7
2
5
7
8
8
3
1
3
6
1
8
2
3
1
0
7
4
4
Q
1
1
8
8
7
1
3
x
7
5
5
4
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 350
350 HYDROLOGY
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
Q
7
0
9
1
1
8
x
2
7
5
9
2
7
.
1
9
1
1
Q
6
9
4
3
1
8
4
3
6
9
1
3
x
2
6
1
0
3
6
2
8
.
1
9
1
2
Q
7
7
0
0
1
6
8
3
3
5
2
x
3
3
6
7
4
0
0
2
2
9
.
1
9
1
4
Q
5
4
1
7
2
9
2
4
9
1
9
x
1
0
8
4
4
9
1
6
Q
6
0
1
8
2
8
x
1
6
8
5
3
0
1
9
1
5
Q
6
5
7
9
2
x
2
2
4
6
Q
7
4
0
7
1
3
x
3
0
7
4
Q
4
7
2
5
2
9
x
3
9
2
3
1
.
1
9
1
6
Q
4
7
2
5
2
6
x
3
9
2
3
2
.
1
9
1
7
Q
8
4
1
6
1
1
5
3
5
2
5
5
4
8
2
9
x
4
0
8
3
1
0
1
9
1
1
4
9
Q
6
8
7
0
2
5
4
9
0
9
2
3
x
2
5
3
7
5
7
6
3
3
.
1
9
1
8
Q
4
6
6
5
2
2
x
3
3
2
3
4
.
1
9
1
9
Q
6
2
9
6
1
3
5
1
6
0
7
x
1
9
6
3
8
2
7
3
5
.
1
9
2
0
Q
4
8
4
8
2
3
8
1
7
4
1
4
x
5
1
5
3
8
4
1
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 351
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 351
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
3
6
.
1
9
2
1
Q
5
6
8
0
2
6
7
6
2
3
4
6
5
0
8
9
x
1
3
4
7
3
2
9
0
2
1
7
5
9
0
7
9
1
8
5
9
5
0
1
5
4
7
4
6
1
6
1
7
3
7
.
1
9
2
2
Q
5
8
1
4
2
0
7
4
0
7
1
7
5
0
3
4
3
x
1
4
8
1
3
0
7
4
7
0
1
3
8
.
1
9
2
3
Q
5
4
8
2
5
x
1
1
4
9
3
9
.
1
9
2
4
Q
5
1
6
0
2
7
6
0
8
7
3
4
8
4
8
5
x
8
2
7
1
7
5
4
5
1
5
Q
5
0
9
7
1
9
1
9
1
3
6
2
9
x
7
6
4
1
4
8
0
3
4
0
.
1
9
2
5
Q
5
1
6
0
2
1
9
6
7
0
1
2
x
8
2
7
5
3
4
7
4
1
.
1
9
2
7
Q
7
2
3
6
5
x
2
9
0
3
Q
7
2
4
1
2
0
x
2
9
0
8
4
2
.
1
9
2
9
Q
4
5
4
5
1
5
x
2
1
2
4
3
.
1
9
3
0
Q
5
4
4
3
2
7
5
9
9
7
2
1
x
1
1
1
0
1
6
6
4
4
4
.
1
9
3
2
Q
5
5
3
2
1
4
x
1
1
9
9
6
1
5
5
2
4
1
8
2
2
4
5
.
1
9
3
3
Q
4
6
9
2
2
5
5
2
6
7
1
5
x
3
5
9
9
3
4
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 352
352 HYDROLOGY
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
4
6
.
1
9
3
4
Q
6
1
9
3
2
1
x
1
8
6
0
4
7
.
1
9
3
5
Q
5
2
8
9
4
x
9
5
6
4
8
.
1
9
4
2
Q
4
8
8
7
2
4
6
6
5
0
9
x
5
5
4
2
3
1
7
4
9
.
1
9
4
3
Q
4
4
4
2
2
2
x
1
0
9
5
0
.
1
9
4
5
Q
4
8
3
6
1
9
5
1
0
1
3
x
5
0
3
7
6
8
5
1
.
1
9
4
6
Q
4
6
2
9
2
8
x
2
9
6
5
2
.
1
9
4
7
Q
4
3
4
5
2
7
x
1
2
5
3
.
1
9
4
8
Q
4
8
9
0
2
5
x
5
5
7
5
4
.
1
9
5
0
Q
4
5
6
2
2
6
5
8
9
9
1
8
x
2
2
9
1
5
6
6
5
5
.
1
9
5
1
Q
4
4
5
8
2
2
4
3
3
9
1
5
x
1
2
5
6
5
6
.
1
9
5
3
Q
5
4
7
0
1
3
x
1
1
3
7
5
7
.
1
9
5
4
Q
5
9
7
8
2
0
x
1
6
4
5
5
8
.
1
9
5
5
Q
4
6
4
4
5
x
3
1
1
5
9
.
1
9
5
6
Q
6
3
8
1
1
1
x
2
0
4
8
(
C
o
n
t
d
.
)
.
.
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-1.PM5 353
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 353
1
2
3
4
5
6
7
8
9
1
0
1
1
1
2
1
3
6
0
.
1
9
5
7
Q
4
5
4
8
1
5
x
2
1
3
6
1
.
1
9
5
9
Q
4
4
9
3
3
x
1
6
0
6
2
.
1
9
6
1
Q
4
8
5
5
1
7
x
5
2
2
6
3
.
1
9
6
2
Q
5
7
6
0
2
8
x
1
4
2
7
6
4
.
1
9
6
3
Q
5
5
7
4
2
1
9
1
9
2
1
7
x
1
2
4
1
4
8
5
9
6
5
.
1
9
6
6
Q
4
7
4
1
2
6
x
4
0
8
6
6
.
1
9
6
7
Q
5
9
1
9
2
7
x
1
5
8
6
6
7
.
1
9
6
9
Q
4
5
4
6
2
0
x
2
1
3
6
8
.
1
9
7
1
Q
4
5
4
2
7
x
2
0
9
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 354
354 HYDROLOGY
Table 15.5 Annual Peak discharges for Ganga river at Hardwar
for the period 1885-1971 (87 yrs) (Example 15.1)
Sl. Year Ann. Peak Log
10
Q Sl. Year Ann. Peak Log
10
Q
no. Q (cumec) no. Q (cumec)
(Contd.)...
1. 1885 7241 3.8598
2. 1886 9164 3.9621
3. 1887 7407 3.8696
4. 1888 6870 3.8370
5. 1889 9855 3.9936
6. 1890 11887 4.0752
7. 1891 8827 3.9458
8. 1892 7546 3.8777
9. 1893 8498 3.9293
10. 1894 16757 4.2242
11. 1895 9680 3.9859
12. 1896 14336 4.1565
13. 1897 8174 3.9124
14. 1898 8953 3.9518
15. 1899 7546 3.8777
16. 1900 6652 3.8229
17. 1901 11409 4.0573
18. 1902 9164 3.9621
19. 1903 7404 3.8694
20. 1904 8579 3.9335
21. 1905 9362 3.9714
22. 1906 7092 3.8507
23. 1907 7546 3.8777
24. 1908 11504 4.0607
25. 1909 8335 3.9209
26. 1910 15077 4.1783
27. 1911 6943 3.8416
28. 1912 8335 3.9209
29. 1913 3579 3.5538
30. 1914 9299 3.9684
31. 1915 7407 3.8696
32. 1916 4726 3.6744
33. 1917 8416 3.9251
34. 1918 4668 3.6698
35. 1919 6296 3.7991
36. 1920 8174 3.9124
37. 1921 9079 3.9580
38. 1922 7407 3.8696
39. 1923 5482 3.7390
40. 1924 19136 4.2818
41. 1925 9680 3.9859
42. 1926 3698 3.5680
43. 1927 7241 3.8598
44. 1928 3698 3.5680
45. 1929 4545 3.6576
46. 1930 5998 3.7780
47. 1931 3470 3.5403
48. 1932 6155 3.7893
49. 1933 5267 3.7216
50. 1934 6193 3.7919
51. 1935 5289 3.7223
52. 1936 3320 3.5211
53. 1937 3232 3.5095
54. 1938 3525 3.5471
55. 1939 2341 3.3694
56. 1940 2429 3.3854
57. 1941 3154 3.4989
58. 1942 6650 3.8228
59. 1943 4442 3.6476
60. 1944 4229 3.6262
61. 1945 5101 3.7077
62. 1946 4629 3.6654
63. 1947 4345 3.6380
64. 1948 4890 3.6893
65. 1949 3619 3.5586
66. 1950 5899 3.7708
67. 1951 4458 3.6492
68. 1952 3919 3.5932
69. 1953 5470 3.7380
70. 1954 5978 3.7766
71. 1955 4644 3.6669
72. 1956 6381 3.8049
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 355
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 355
Solution The histogram of annual flood peaks for the Ganga river at Hardwar for the period
1885-1971, 87 years, is shown in Fig. 15.2. The computation of the cumulative frequency curve
is made in Table 15.6.
It is seen that the distribution of floods do not have the normal bell-shaped curve but
they are skewed. However, the data can be transformed by plotting the common logarithm of
the flood peaks so that the distribution density curve is approximately normal as shown in Fig.
15.3. This is then called a log normal distribution and the standard deviation is in logarithmic
units. The histogram of the partial-duration series of the flood peaks above the selected base of
4333 cumec is shown in Fig. 15.4, which also represents skewed data.
Table 15.6 Computation of the cumulative frequency curve
Annual No. of Cumulative Probability
flood peak occurrences occurrences
=
F
H
G
I
K
J
CF
f
100

%
C.I. or or
(1000 cumec) frequency, f frequency, CF
0-2* 0 87 100
2-4* 17 87 100
4-6 27 70 80.5
6-8 18 43 49.5
8-10 18 25 28.8
10-12 3 7 8.05
12-14 0 4 4.6
14-16 2 4 4.6
16-18 1 2 2.3
18-20 1 1 1.15
f = 87
*0-<2.
2- <4, and like that.
(a) Partial duration series. There are 175 flood exceedances (above Q
b
) during 87
years. Average number of exceedances per year.
=
175
87
= 2.01
73. 1957 4548 3.6579
74. 1958 4056 3.6081
75. 1959 4493 3.6525
76. 1960 3884 3.5893
77. 1961 4855 3.6861
78. 1962 5760 3.7604
79. 1963 9192 3.9634
80. 1964 3024 3.4806
81. 1965 2509 3.3994
82. 1966 4741 4.6759
83. 1967 5919 3.7725
84. 1968 3798 3.5795
85. 1969 4546 3.6577
86. 1970 3842 3.5845
87. 1971 4542 3.6573
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 356
356 HYDROLOGY
Parameter is estimated in the following Table.
Sl. Flood peak exceedance Observed Cumulative H(x) 1 H(x)
no. x
i
(cumec) frequency frequency =
CF
175
=
1n {1 H(x)}
x
CI Variable CF ... 10
4
1. below-2500 2500 107 107 0.6114 0.3886 3.362
2. 2500-5000 5000 51 158 0.9029 0.0971 4.649
3. 5000-7500 7500 10 168 0.9600 0.0400 4.282
4. 7500-10000 10000 3 171 0.9771 0.0229 3.762
5. 10000-12500 12500 3 174 0.9443 0.0057 4.119
6. 12500-15000 15000 1 175 1.0000 0.0000
Mean = 6635 cumec
Median = 7000 cumec
Mode = 5000 cumec
Cumulative
frequency (%) curve
100
80
60
50 %
40
20
0
0 2 4 6 8 10 12 14 16 18 20
Q (1000 cumec)
P
r
o
b
a
b
i
l
i
t
y
(
%
)
M
e
d
i
a
n
Histogram
Normal
curve
(Mean = median = mode)
Frequency
curve - skewed
Modal class
f = 27 max.
F
r
e
q
u
e
n
c
y
o
r
n
o
.
o
f
o
c
c
u
r
r
e
n
c
e
s
30
25
20
15
10
5
0
0
-
2
2
-
4
4
-
6
8
-
1
0
1
0
-
1
2
1
2
-
1
4
1
4
-
1
6
1
6
-
1
8
1
8
-
2
0
C of Q (1000 cumec) I
L
md
C.I.7
x
M
o
d
e
C
e
n
t
e
r
o
f
g
r
a
v
i
t
y
M
e
a
n
.
M
e
d
i
a
n
d
1
d
2
c.g.
Fig. 15.2 Histogram of annual floods of river Ganga (1885-1971)
$ % """""" & """"""
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 357
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 357
Log normal (skew = 0)
curve
Log - pearson (skew = 0.81) III
Histogram
N
o
.
o
f
o
c
c
u
r
r
e
n
c
e
s
50
40
30
20
10
0
3
.
0
-
3
.
2
3
.
2
-
3
.
4
3
.
4
-
3
.
6
3
.
6
-
3
.
8
3
.
8
-
4
.
0
4
.
0
-
4
.
2
4
.
2
-
4
.
4
C. of Log Q (cumec)
Fig. 15.3 Histogram of logarithm of annual floods of river Ganga (1885-1971)
100
90
80
70
60
50
40
30
20
10
0
N
o
.
o
f
o
c
c
u
r
r
e
n
c
e
s
Skewed distribution
of partial duration floods
0
-
2
2
-
4
4
-
6
6
-
8
8
-
1
0
1
0
-
1
2
1
2
-
1
4
1
4
-
1
6
1
6
-
1
8
1
8
-
2
0
C of Q (1000 cumec) (>Q = 4333 cumec) I
b
Fig. 15.4 Histogram of partial duration floods in river Ganga (18851971)
The average value of =

= 4.05 10
4
Estimation of design flood can now be done from Eqs. (15.24) and (15.25)
Q
T
= Q
b
+ x
T
Q
T
= 4333 +
10
4 05
4
.
[ln (2.01 T) ln {ln (2.01 T)}] ...(15.26)
T-yr: 1000 500 200 100 50
Q
T
(cumec): 18103 16605 14728 13296 11938
Q
T
by T =
n 1
m
+
: 23600 21600 18900 17000 15100
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 358
358 HYDROLOGY
15.4 ANNUAL FLOOD PEAKSRIVER GANGA
(i) Gumbels method Eq. (15.6):
Q
T
= Q + K
Q = 6635.63 cumec, = 3130.8 cumec
K =
y y
n
n

From Table 15.5 for n = 87, y


n
= 0.55815,
n
= 1.1987
T-yr X
T
= log log
T
T 1
F
H
G
I
K
J
Y = 0.834 2.3 X
T
K =
y y
n
n

Q
T
= Q + K
1000 3.361 6.907 5.29 23185
500 3.060 6.213 4.7 21335
200 2.662 5.295 3.95 19005
100 2.360 4.600 3.36 17155
50 2.056 3.901 2.79 15365
(ii) Stochastic Method Eq. (15.17):
Q
min
= 2341 cumec;
Q
= 6635.63 cumec; n
f
= 77
Q
T
= Q
min
+ 2.3 (
Q
Q
min
) log
n
n
T
f
.
F
H
G
I
K
J
= 2341 + 2.3 (6635.63 2341) log
77
87
.
T
F
H
G
I
K
J
Q
T
= 2341 + 9890 log (0.885 T) ...(15.27)
T-yr 0.885 T log (0.885 T) 9890 log (0.885 T) Q
T
cumec
1000 885 2.947 29200 31541
500 442.5 2.646 26200 28541
200 177 2.248 22200 24541
100 88.5 1.947 19200 21541
50 44.25 1.646 16260 18601
(iii) Log-Pearson Type III distribution. For the grouped data of annual floods in Table
15.7, computations are made in Table 15.5 to obtain the statistical parameters of the Log-
Pearson Type-III distribution [see Eqs. (14.27 a, b, c)].
Mean: log x =

f x
f
(log )
=
67 3856
87
.
= 0.7750
Std. dev:
log x
=
f x x
n
(log log )

2
1
=
3 3315
87 1
.

= 0.1962
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 359
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 359
C
I
M
i
d
-
p
t
.

o
f

C
I
F
r
e
q
u
e
n
c
y
(
1
0
0
0
x
f
l
o
g

x
f

l
o
g

x
l
o
g

x
(
l
o
g

x
(
l
o
g

x
f
(
l
o
g

x
f
(
l
o
g

x
c
u
m
e
c
)
(
1
0
0
0

c
u
m
e
c
)


l
o
g
x


l
o
g
x
)
2


l
o
g
x
)
3


l
o
g
x
)
2


l
o
g
x
)
3
0
-
2
1
0
0
0
0
0
0
0
0
2
-
4
3
1
7
0
.
4
7
7
1
8
.
1
0
0
0

0
.
2
9
7
9

0
.
0
8
9
0

0
.
0
2
6
5
1
.
5
1
2
0

0
.
4
5
0
0
4
-
6
5
2
7
0
.
6
9
9
0
1
8
.
9
0
0
0

0
.
0
7
6
0
0
.
0
0
5
8

0
.
0
0
0
4
4
0
.
1
5
6
0

0
.
0
1
1
9
6
-
8
7
1
8
0
.
8
4
5
1
1
5
.
2
0
0
0
0
.
0
7
0
1
0
.
0
0
4
9
0
.
0
0
0
3
0
.
0
8
8
5
0
.
0
0
6
2
8
-
1
0
9
1
8
0
.
9
5
4
2
1
7
.
2
0
0
0
0
.
1
7
9
2
0
.
0
3
4
0
0
.
0
0
5
7
0
.
5
7
9
0
0
.
1
0
2
5
1
0
-
1
2
1
1
3
1
.
0
4
1
4
3
.
1
2
4
2
0
.
2
6
6
4
0
.
0
7
1
0
0
.
0
1
9
0
0
.
2
1
3
0
0
.
0
5
7
0
1
2
-
1
4
1
3
0
1
.
1
1
3
9
0
.
0
0
0
0
0
.
3
3
8
9
0
.
1
1
5
0
0
.
0
3
9
0
0
.
0
0
0
0
0
.
0
0
0
0
1
4
-
1
6
1
5
2
1
.
1
7
6
1
2
.
3
5
2
2
0
.
4
0
1
1
0
.
1
6
1
0
0
.
0
6
4
4
0
.
3
2
2
0
0
.
1
2
8
8
1
6
-
1
8
1
7
1
1
.
2
3
0
4
1
.
2
3
0
4
0
.
4
5
5
4
0
.
2
0
7
0
0
.
0
9
4
0
0
.
2
0
7
0
0
.
0
9
4
0
1
8
-
2
0
1
9
1
1
.
2
7
8
8
1
.
2
7
8
8
0
.
5
0
3
8
0
.
2
5
4
0
0
.
1
2
8
0
0
.
2
5
4
0
0
.
1
2
8
0

n

=

f

=

8
7

f
.

l
o
g

(
x
)

=

6
7
.
3
8
5
6
3
.
3
3
1
5
0
.
5
1
6
5
F
o
r

g
r
o
u
p
e
d

d
a
t
a
:

l
o
g
x

=

f
x
f
.
l
o
g
(
)

=

6
7
3
8
5
6
8
7
.

=

0
.
7
7
5
0
T
a
b
l
e

1
5
.
7
.

L
o
g
-
P
e
a
r
s
o
n

T
y
p
e
-
I
I
I

d
i
s
t
r
i
b
u
t
i
o
n

f
o
r

t
h
e

a
n
n
u
a
l

f
l
o
o
d
s

o
f

r
i
v
e
r

G
a
n
g
a

(
1
8
8
5
-
1
9
7
1
)

(
E
x
a
m
p
l
e

1
5
.
1
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 360
360 HYDROLOGY
Skew: g =
n f x x
n n
x
(log log )
( )( )( )
( . )
( )( )( . )
log


=

3
3 3
1 2
87 0 5165
87 1 87 2 0 1962
= 0.81
Putting variate x = flood peak Q(1000 cumec), the distribution Eq. (14.28) becomes
log Q
T
= log Q + K
log Q
...(15.28)
and Q
T
for any desired T can be computed by knowing the value of K for g = 0.81 and desired
T from Table 14.2.
K = f(g, T) K .
log Q
log Q
T
Q
T
T-yr from Table (
log Q
= 0.1962) = log Q + K
log Q
(1000 cumec)
14.2 ( log Q = 0.7750)
2 0.132 0.0259 0.7491 5.611
5 0.779 0.1530 0.9280 8.472
10 1.336 0.2620 1.0370 10.89
25 1.996 0.3910 1.1660 14.66
50 2.458 0.4820 1.2570 18.07
100 2.898 0.5670 1.3420 21.98
200 3.321 0.6500 1.4250 26.61
100 50 20 10 5 1 0.5 0.1 0.05 0.01
1 2 3 4 5 6 8 10 20 30 40 60 80 100 200 400 600 1000 2000 4 6 10000
45
40
35
30
25
20
15
10
5
0
45
40
35
30
25
20
15
10
5
0
10
3
F
l
o
o
d
p
e
a
k
Q
(
1
0
0
0
c
u
m
e
c
)
T
Recurrence interval (T-yr)
Probability P% of > Q
T
Once in any year for annual floods
3 to 5 times in any year for partial floods

4
3
5
1
2
P
a
rtia
l
flo
o
d
s
=
1
7
5
,
T
=
n
+
1
m
Q
=
4333
+
[
(2.01
T)
T
ln
l
l
n
n
{
(2.01
T)}]
partial floods
=
175, >4333
cum
ec
: S
tochastic
m
odel
10
4.05
4
Q
=
6
6
3
5
+
3
1
3
1
(
)
G
u
m
b
e
l:
8
7
a
n
n
u
a
l
flo
o
d
s
T
y

0
.5
6
1
.2
Plotting
position
(175 partial floods)
T =
n + 1
m
Observed 87-yr
flood = 19136 cumec
S
to
c
h
a
s
tic
m
o
d
e
l
:
8
7
a
n
n
u
a
l
flo
o
d
s
Q
=
2
3
4
1
+
9
8
9
0
lo
g
(
0
.8
8
5
T
)
T
L
o
g

P
e
a
r
s
o
n
T
y
p
e
I
I
I
L
o
g
Q
=
0
.
7
7
5
+
0
.
1
9
6
2
K
T

8
7
a
n
n
u
a
l
f
l
o
o
d
s
(
g
r
o
u
p
e
d
d
a
t
a
)
1 2 3
4 5
Semi-log paper
R. Ganga at Haridwar (n. India): flood frequency
87 years annual flood peaks (1885-1971) curves
175 partial floods > 4333 cumec (1885-1971)

800
Fig. 15.5 Flood-frequency curves of River Ganga at Hardwar (1885-1971)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 361
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 361
The frequency curve Q
T
vs. T is drawn on log-log paper (Fig. 15.6) and also compared
with other well known distributions in Fig. 15.5. Chow (1951) has shown that most frequency
distributions can be generalised as
Q
T
= Q + K
Q
...(15.29)
where K is the frequency factor.
Observed (88-yr)
flood - 19136 cumec
L
o
g
Q
=
0
.7
7
5
0
+
0
.1
9
6
2
K
T
Log-Pearson Type-
frequency curve
III
Log-log paper
1000
500
200
100
60
40
30
20
15
10
8
6
4
3
2
1
1 1.5 2 3 4 5 6 8 10 20 30 50 70 100 200 500 1000
Recurrence interval (T-yr)
Q
,
(
1
0
0
0
c
u
m
e
c
)
T
Fig. 15.6 Log-Pearson Type-III distribution, Ganga floods (1885-1971)
The flood frequency curves by the above four methods have been plotted on semi-log
paper, (Fig. 15.5). It can be seen that the highest annual flood peak of 19136 cumec during a
period of 87 years T =
+
=
F
H
G
I
K
J
87 1
1
88 yr has exceeded the 100-yr flood given by Gumbels method
and that computed by the new stochastic model based on the partial duration series. However,
in this case, the stochastic method using annual flood data and Log-Pearson Type-III distribu-
tion give safe design values.
15.5 REGIONAL FLOOD-FREQUENCY ANALYSIS (RFFA)
A regional analysis becomes necessary when the available data on a catchment are too short
for making a frequency analysis. Data for a long period available from neighbouring catchments
are statistically tested for homogeneity. A group of stations satisfying the test are identified
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 362
362 HYDROLOGY
which constitute a region. All the available data at various stations of this region are analysed
to establish the frequency characterstics of the region. The mean annual flood (
Q
) corresponding
to T = 2.33 yr is used for non-dimensionalysing the results. The variation of mean flood (
Q
)
with the drainage area (A), and the variation Q
T
/
Q
(called growth factor, GF) with the return
period (T), are the basic plots prepared in such analysis.
RFFA for catchments of north Brahmaputra*
For estimation of floods of desired return period (T) for small and moderate size gauged catch-
ments of north Brahmaputra river system, using the GEV-distribution, etc., the relationship
is established as
Q
T
= Q
+
F
H
G
I
K
J
R
S
T
U
V
W
L
N
M
M
O
Q
P
P

1167 12 48 1
1
0.025
. . ln
T
...(15.30)
Flood-frequency estimates may be obtained by multiplying the mean annual flood peak
(
Q
) of the gauged catchment by the corresponding value of the growth factor, Fig. 15.7.
4
3
2
1
0
1 2 3 6 10 2 3 6 100 2 3 6 1000
2.8
G
r
o
w
t
h
f
a
c
t
o
r
(
G
F
)
Return period (T-yr)
Semi-log paper
GF =
Q
Q
T
Q = Q GF
T
Q = 7 tcm
Q = 7 2.8 = 19.6 tcm
500 yr
500 yr
tcm = 1000 cumec
Fig. 15.7 Growth factor for gauged catchments for T-yr flood
For ungauged catchments, while there are no flow data and an estimation of a T-yr
flood is required at a site for which an estimate of
Q
is required.
For gauged catchments in the region of similar pertinent physiographic and climatic
characterstics, in north Brahmaputra, a regional relationship has been developed in terms of
catchment area (A (km
2
)), for estimation of
Q
for ungauged catchments as
Q = 4.375 A
0.72
...(15.31)
*Rakesh kumar, et. al., Development of Regional Flood Formulae using L-moments for Gauged
and Ungauged Catchments of North Brahmaputra River System. Journ. of Inst. of Engrs. (India), Vol.
84, May 2003, P 5763.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 363
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 363
Substituting this in Eq. (15.30),
Q
T
= A
0.72
+
F
H
G
I
K
J
R
S
T
U
V
W
L
N
M
M
O
Q
P
P

5105 54 6 1
1
0.025
. . ln
T
...(15.32)
which gives a T-yr flood (Q
T
cumec) for ungauged catchments of area A km
2
. This is graphi-
cally represented in Fig. 15.8.
100 2 3 5 7 1000 2 3 5 7 10000
Catment area A (km
2
)
100
2 3
240 km
2
10000
8
6
4
3
2
1000
8
6
4
3
2
680
F
l
o
o
d
Q
(
c
u
m
e
c
)
T
Log-Log paper
A = 240 km
2
Q
500 yr
= 680 m /s
3
1000
500
200
100
50
25
10
2
T = yr
Fig. 15.8. Q
T
for unguged catchments of area A
In this RFFA screening of data is done by using the Discordancy measure (D
i
), the
L-moment homogeneity test, i.e., Heterogeneity measure (H) and various distributions like
GEV etc., for which regional parameters are estimated using L-moments approach.
PROBLEM8
1 For the annual floods of Lower Tapti river at Ukai, 30 years (1939-1968) given in Example 8.5,
determine the 2, 10, 50, 100, 200 and 1000-yr flood magnitudes assuming Log-Pearson Type-III
distribution. Draw the frequency line in Fig. 15.1 and compare with the other well-known fre-
quency distributions.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 364
364 HYDROLOGY
2 Repeat problems in question No. 4, 5, 6, 7 and 18 at end of Chapter 8.
3 For the readings of Gauge height and Discharge for a stream, given in question no. 6 at the end
of Chapter 6, obtain the Linear regression equation and find the discharge for the gauge read-
ings of 1.6 m and 2.5 m.
4 For the annual floods of the river Ganga at Hardwar for 87 years (1885-1971) given in Example
15.1, determine the Fosters Type-III flood-frequency curve and plot on the semi-log paper in
Fig. 15.5; compare it with the other well-known flood-frequency distributions.
5 Given below are the flood records for 15 years at Bhakra dam site on Sutlej river, determine by
any frequency method:
(i) The 60-100-and 200-year floods
(ii) The flood magnitude having a 1% chance of occurrence in any one year
(iii) The recurrence interval of flood peaks of 6000 and 12000 cumec
Comment on the limitations of flood-frequency analysis on such short records.
Flood Flood
Year peak Year peak
(cumec) (cumec)
1937 3110 1945 2380
38 5800 46 3810
39 3090 47 7800
40 1723 48 4525
41 3630 49 3250
42 6600 50 4980
43 5260 1951 9200
44 2290
[Ans. i. 13.5, 15, 16.9 tcm; ii 1% = 100 yr = 15 tcm; iii 4
1
2
yr, 36 yr, not a true distribution series
for extrapolation]
6 The annual flood peaks for 32 years (1948-1979) in the river Narmada at Garudeshwar are given
below (tcm = 1000 cumec).
Obtain the 500-yr and 1000-yr floods by (a) Gumbels EV Type-I, (b) Log normal, and (c) Log-
Pearson Type-III, methods.
Year Flood Year Flood
peak peak
(tcm) (tcm)
1948 25.3 1964 19.5
1949 26.8 1965 15.2
1050 45.5 1966 13.0
1951 10.4 1967 22.6
1952 14.1 1968 58.0
1953 17.1 1969 31.2
1954 28.4 1970 69.4
(Contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD15-2.PM5 365
FLOOD FREQUENCYPROBABILITY AND STOCHASTIC METHODS 365
1955 29.0 1971 20.0
1956 12.8 1972 48.0
1957 26.7 1973 61.2
1958 19.7 1974 27.3
1959 38.8 1975 33.7
1960 21.3 1976 19.5
1961 43.2 1977 22.7
1962 38.8 1978 34.2
1963 15.2 1979 38.1
[Ans. 103.4, 114; 120, 134; 127, 144 tcm
( x = 29.6 tcm, = 14.86 tcm)
(MPF = 125 tcm)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
16.1 TYPE OF MATHEMATICAL MODELS
The mathematical models in Hydrology can be classified as:
(a) Stochastic models
(b) Deterministic models
In the stochastic model, the chance of occurrence of the variable is considered thus
introducing the concept of probability. A stochastic model is time-dependent while the
probabilistic model is time-independent. For the time-independent probabilistic process, the
sequence of occurrence of the variates involved in the process, is ignored and the chance of
their occurrence is assumed to follow a definite probability distribution in which the variables
are considered pure random. For the time-dependent stochastic process, the sequence of oc-
currence of the variates is observed and the variables may be either, pure random or non-pure
random, but the probability distribution of the variables may or may not vary with time. For
example, the flow duration curve procedure is probabilistic, whereas the flood routing through
a reservoir is a stochastic procedure.
In the deterministic models, the chance of occurrence of the variables involved is ig-
nored and the model is considered to follow a definite law of certainty but not any law of
probability. For example, the mathematical formulation of the unit-hydrograph theory is a
deterministic model.
Both the stochastic and deterministic models can be sub-classified as
(i) Conceptual models (ii) Empirical models
In conceptual models, a mathematical function is conceived based on the consideration
of the physical process, which when subjected to input variables, produces the output vari-
ables. For example, a conceptual catchment model of rainfall-runoff relationship can be de-
scribed by
[i(t)] = Q(t) ...(16.1)
where i(t) = input, i.e., rainfall
Q(t) = output, i.e., runoff
= system operator, i.e., it represents the operation performed by the system to yield
the output for the given input.
Empirical models are based on empirical relationships or formulae like Dickens, Ryves,
Inglis, etc., where one composite coefficient takes into account all the variables affecting
Chapter 16
366
MATHEMATICAL MODELS IN HYDROLOGY
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 367
MATHEMATICAL MODELS IN HYDROLOGY 367
possible flood peaks in a catchment; all the complex physical laws involved may not be considered
here.
Examples of mathematical models. A conceptual or empirical model could be either de-
terministic or stochastic or a combination of these. For example, the model for predicting sedi-
ment transport is a combination of deterministic and stochastic components, which are often
based on empirical relationships, where as models based on regression analysis are stochastic
conceptual models with a strong deterministic approach. Models concerning the propagation
of flood wave and Nash model (cascade of linear reservoirs) are the examples of deterministic
conceptual models, while models based on synthetic unit hydrograph are the examples of de-
terministic empirical models.
Optimisation of model and efficiency of model. A system is a set of elements organised to
perform a set of designated function in order to achieve desired results. The project formula-
tion of the system may be called system design. The objective of system design is to select the
combination of system units or variables that maximises net benefits in accordance with the
requirement of the design criteria. The design so achieved is known as the optimal design. The
optimisation is subject to the requirements of the design criteria or constraints that are im-
posed. The constraints may be technical, budgetary, social or political and the benefits may be
real or implied. When an objective is translated into a design criterion, it may be written in the
form of a mathematical expression known as the objective function.
For mathematical model, the objective function which should be optimised is given by
the equation
F =
i
n
=

1
(Q
i
Q
i
)
2
...(16.2)
where Q
i
= actual observed value
Q
i
= value predicted by model
The objective of the optimisation procedure is to obtain such sets of parameter values,
which reduce the least squares objective function F to zero. For testing the significance and
reliability of the optimised parameter values, statistical tests, predictive tests and sensitivity
tests are often employed. Nash, et al (1970) have suggested the use of model efficiency (R
2
) to
evaluate the performance of the model.
R
2
=
F F
F
0
0

...(16.3)
where F
0
=
i
n
=

1
(Q
i
Q )
2
...(16.3a)
Q =
i
n
i
Q
n
=

1
= mean of n observed values
R
2
is analogous to the coefficient of variation and is proportional to initial variation
accounted by the model. The efficiency of a separable model part (r
2
) can be judged by a change
in the value of R
2
resulting by the insertion of that part or by the proportion of residual vari-
ance accounted for by its insertion.
r
2
=
R R
R
F F
F
2
2
1
2
1
2
1 2
1
1

...(16.4)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 368
368 HYDROLOGY
Predictive testing on a split sample basis is adopted in which the available data is di-
vided into two parts; the first part is used to estimate the optimised parameter values and
then, these are used to predict or reconstruct the second part of the data record. Sensitive tests
generally test the effect of varying the optimised parameter value or the data on the objective
function. This gives an idea of stability of the optimised parameter values or data error effects.
Two studies on these lines are given below.
Excess rainfall-direct-runoff modelA model study was done at Roorkee (1976) using
the data of a small catchment. Fig. 16.1, having a non-uniform-rainfall distribution. The val-
ues of n and K obtained by the method of moments in a Nash Model (1957)* were not able to
Bridge
no. 566
To katol
To Nagpur
Sub area A
3
Sub area A
1
Catchment
boundary
Bar kher
Gh at Baroli
Kherwari
Sub area A
2
Karpa
Wagh
oli
Betul
To Badnpur
Rain gauge stn.
a. Small catchment divided into
three sub areas - A , A & A
1 2 3
Sub area A
2
Sub area A
1
I
2
I
1
Linear
reservoirs
n = 5.32
2
k = 0.45 hr
2
n = 5.22
1
k = 0.435
hr
1
Sub area A
3
Linear
channel
o
1
o
2
I
3
O
3
O + O + O
2 3 1
n = 4.81
3
k = 0.279hr
3
b. Model of linear reservoirs and linear channel
Fig. 16.1 Rainfall-runoff model (Roorkee, 1976)
simulate the peak of the observed hydrograph, though the values of the model efficiencies R
2
=
83.7% and 82.3% were obtained for the hydrograph used to derive the values of n and K, and
the hydrograph of direct runoff, respectively. Then the catchment was divided into three sub-
areas and each sub-area was modelled by means of cascade of linear reservoirs of equal stor-
age coefficient. The values of n and K for each sub-area were obtained by using physiographic
*Nash (1957) used a series of n linear reservoirs of equal storage coefficient K, to obtain the instan-
taneous unit hydrograph assuming a lumped input and linear, time-invariant, deterministic system.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 369
MATHEMATICAL MODELS IN HYDROLOGY 369
features of the catchment. The outflow from sub-areas A
1
and A
2
was combined together and
then led through a linear channel having a translation constant T; it was then combined with
outflow of sub-area A
3
to obtain the values of direct runoff for the whole catchment. The model
efficiency R
2
= 82.3% and 90% for the first and second hydrographs, respectively. However,
further analysis had to be made for investing the effect of loss assumptions and non-uniform
rainfall distribution, and possibly inclusion of translation concept by dividing the sub-areas by
means of isochrones and representing them by combination of linear channel and linear reser-
voir in series.
Rainfall-runoff model based on retention concept. The retention concept of dividing the
rainfall into runoff and non-runoff volumes is based on the physical processes of soil moisture
retention. Model based on the retention concept was used by Seth (1972) for simulating the
rainfall-runoff process of a small catchment. Its main components were those used to represent
the retention capacity Y and evapotranspiration capacity E. Retention storage S was defined
as that volume of water present in a natural watershed, which is not runoff storage. The
maximum storage volume V of the retention storage of the catchment was subdivided into V
1
and V
2
for the upper and lower layer of soil, respectively. The moisture storage at any time,
i.e., retention storage in the upper and lower layers were S
1
and S
2
, respectively, and the ratio
of S
1
/V
1
and S
2
/V
2
characterised the moisture status of the upper and lower layers, respectively
V = V
1
+ V
2
...(16.5)
S = S
1
+ S
2
...(16.5a)
Precipitation
Rainfall
excess (P
net
)
Infiltration (F) Other abstractions
Subsurface
flow
Deep
percolation
Ground water
Delayed
interflow
Prompt
interflow
Direct surface
runoff, DSR(Q )
d
Base flow (BF)
Total runoff
(TR or Q)
Fig. 16.2 Rainfall-runoff system
These components together with other components of the model gave a good perform-
ance when about a years data of 2560 data pieces of 3 hourly values of rainfall, runoff and
potential evaporation of Grendon Underwood Catchment of Institute of Hydrology (UK), were
used. The values of F = 14.07 mm
2
and R
2
= 0.912 obtained after optimisation run, compared
quite favourably with those obtained by using the Stanford Model for the same data. The
model values of soil moisture retained in soil gave almost a similar pattern as the observed soil
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 370
370 HYDROLOGY
moisture. However, to take into account the full range of seasonal variations, it would be
desirable to include a wide range of antecedent and storm period conditions existing perhaps
over several years.
Rainfall-runoff system model. The rainfall to runoff transformation as a system is shown
in Fig. 16.2.
A famous computer model is the Stanford Watershed Model (Crawford and Linsley,
1966). This model is refined progressively and is now a very comprehensive model based on
water budgeting. By using hourly precipitation data and daily evapotranspiration as the main
inputs, the model is programmed to produce hourly streamflow. Soil, vegetation, land use,
etc., are all accounted for by a set of parameters, the values for which are progressively optimised
by search technique. The flow diagram for the model is shown in Fig. 16.3 a which is, typical
flow chart for a rainfall-runoff model of the explicit soil moisture accounting type, ESMA,
redrawn from Linsley and Crawford (1974).
KEY
Input
Output
Storage
Functions
Precipitation potenial
evapotranspiration
temperature
radiation
Snow melt
Interception
Impervious
area
Infiltration
Inter-
ception
storage
Evapo-
transpi-
ration
Actual
evapotranspiration
Evapo-
transpi-
ration
Evapo-
transpi-
ration
Evapo-
transpi-
ration
Deep or
inactive ground
water storage
Ground-
water
storage
Active or
deep ground
water storage
Simulated
streamflow
Channel
outing
Channel
inflow
Lower
zone
storage
Lower zone or
ground water
storage
Upper
zone
depletion
Upper
zone
storage
Upper
zone
Surface
runoff
interflow
Upper
zone
depletion
Over-
land
flow
Channel
inflow
Channel
inflow
Channel
inflow
Fig. 16.3 Flow diagram of stanford watershed Model IV, ESMA
(after Linsley and Crawford, 1974)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 371
MATHEMATICAL MODELS IN HYDROLOGY 371
16.2 METHODS OF DETERMINING IUH
1. By the S-Curve Hydrograph
In Fig. 16.4, S
t
is the S-curve ordinate at any time t (due to t
r
-hr UG) and S
t
is the ordinate at
time t of the S-curve lagged by t
r
-hr, then the t
r
-hr UGO at time t can be expressed as
U(t
r
, t) = (S
t
S
t
)
t
t
r
r

...(16.6)
dt
dS
t
S
t
S
t
t
r
Lag
t
Time (hr)
Lim (S - S ) = d S
t 0
t t t
r

( UHO) = = Slope of
S - Curve
I
t
d S
dt
t
D
i
s
c
h
a
r
g
e
(
c
u
m
e
c
)
Fig. 16.4 IUH as S-curve derivative
As t
r
progressively diminishes, i.e., t
r
0, Eq. (16.6) reduces to the form (as can be seen
from Fig. 16.4)
U(0, t) =
dS
dt
t
...(16.7)
i.e., the ordinate of the IUH at any time t is simply given by the slope of the S-curve at time t;
in other words, the S-curve is an integral curve of the IUH. Since the S-curve derived from the
observed rainfall-runoff data can not be too exact, the IUH derived from the S-curve is only
approximate. The IUH, reflects all the catchment characteristics such as length, shape, slope,
etc., independent of the duration of rainfall, thereby eliminating one variable in hydrograph
analysis. Hence, it is useful for theoretical investigations on the rainfall-runoff relationships
of drainage basins. The determination of the IUH is analytically more tedious than that of UG
but it can be simplified by using electronic computers.
The t
r
-UGO can be obtained by dividing the IUH into t
r
-hr time intervals, the average of
the ordinates at the beginning and end of each interval being plotted at the end of the interval
(Fig. 16.5).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 372
372 HYDROLOGY
A
B
C
D
E
D + E
2
t hr UG
r
IUH derived
from S-curve
C + D
2
B + C
2
A + B
2
D
i
s
c
h
a
r
g
e
(
c
u
m
e
c
)
Time (hr)
t
r
t
r
t
r
t
r

Fig. 16.5 t
r
-hr UG derived from IUH
2. By Using a Convolution Integral
By the principle of superposition in the linear-unit-hydrograph theory, when a net rainfall of
function i(t) of duration t
0
is applied, each infinitesimal element of P
net
will produce a DRO,
i.e., Q(t) given by
Q(t) =
0
t
u t i d

z
( ) . ( ) ...(16.8)
the upper limit t given by
t = t, when t t
0
t = t
0
, when t t
0
Eq. (16.8) is called the convolution integral (or Duhamel integral) in which u (t

) is a
kernel function, i() is the input function.
The shape of the IUH in Fig. 16.6 resembles a single peaked hydrograph. If the rainfall
and runoff in the convolution integral are measured in the same units, the ordinates of the
IUH have the dimension
1
time
.
The properties of the IUH are given by
0 u(t) a positive peak value, for t > 0
u(t) = 0 for t 0
u(t) 0 for t ...(16.9)
0

z
u(t)dt = 1.0 and
0

z
u(t) dt = t
i
where t
i
= lag time of IUH = time interval between the centroid of P
net
and that of direct runoff.
See next chapter 17 on IUH.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 373
MATHEMATICAL MODELS IN HYDROLOGY 373
a.
b.
c.
Q(t)
O
t time t
Run-off
hydrograph
Q(t) = u (t ).i( ) d t t t
o
t
t = t, when t t
o
t = t , when t > t
o o
time t
u (t ) t
IUH
t t
O
u
(
t

)
t
O
time t
Rainfall
intensity
i( ) t
t
dt
t
0
u( ) t
Fig. 16.6 Convolution of i() and IUH
3. By Conceptual Models
Various conceptual models have been proposed to develop the IUH. They may be of physical
analogy or mathematical simulation composed of linear reservoirs, linear channels, or time-
area diagrams.
(a) Linear Reservoirs
A mathematical simulation of a drainage basin consisting of a series of linear reservoirs
as proposed by J.E. Nash (1957) is discussed below:
A linear reservoir is a fictitious reservoir in which the storage is directly proportional to
outflow, i.e., S = KO.
From the principle of continuity
I O =
ds
dt
...(16.10)
From the condition O = 0 when t = 0, and that S = KO,
O = I(1 e
t/k
) ...(16.11)
when t = , O = I, i.e., the outflow approaches an equilibrium condition and equals inflow. If
the inflow terminates at time t
0
since outflow began, a similar derivation gives the outflow at
time t in terms of out flow O
0
at t
0
, as
O
t
= O
0
e
t t K ( )/
0
...(16.12)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 374
374 HYDROLOGY
For an instantaneous inflow, which fills the reservoir storage S in time t
0
= 0, and since
S = KO, O
0
=
S
K
, hence from Eq. (16.12)
O
i
=
S
K
e
t/K
...(16.13)
For a unit input or S = 1, the IUH of the linear reservoir is given by
u(t) =
1
K
e
t/K
...(16.14)
This is represented by the hydrograph for the outflow from the first reservoir as shown
in Fig. 16.7.
O
1
O
1
O
3
O
4
O
n
O
n 1
I
Linear storage
reservoirs
Q
1
t
Q
2
t
Q
3
t
Q
n
t
Q
4
Q
n1
Hydrographs
(O = Q)
i i
Fig. 16.7 Routing through linear reservoirs (Nashs Model)
(b) Simulation of Linear Channels
A linear channel is a fictitious channel in which the time T required to translate a
discharge Q of any magnitude through a given channel reach of length x is constant. Hence,
when an inflow hydrograph is routed through the channel, its shape will not change. At a
given section, the relation between the water area A and the discharge Q is linear (assuming
velocity to be constant), i.e.,
A = CQ
where C = f(T) called translation coefficient which is constant at a given section.
If a segment of inflow of duration t and volume S is routed through a linear channel,
Fig. 16.8, the outflow is given by
O = S (t, t) ...(16.15)
where (t, t) =
1
t
...(16.16)
for 0 t and t = + T; it is zero otherwise, where is the time measured from the beginning
of the segment. Eq. (16.16) is a pulse function. When t 0, this equation becomes an im-
pulse function (t), known as a Dirac-delta function, which represents the IUH for the linear
channel.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 375
MATHEMATICAL MODELS IN HYDROLOGY 375
I
=
f
(
t
)
O
=
f
(
t

)
t
D
i
s
c
h
a
r
g
e
Inflow hydrograph
(segment)
Outflow hydrograph
(segment)
time t
Dt
t
T
t
t
Dt
Fig. 16.8 Routing through linear channel
4. Routing TimeArea Curve of Basins
The principles of flood-routing can be used to derive unit hydrographs for a catchment where
there are no complete records of rainfall-runoff.
The catchment may be divided into a series of sub-areas, each contributing inflow into
drainage channels (which have storage) due to a flash storm. The IUH can be divided into two
partsthe first representing inflow of the rain, and second, the gradual withdrawal from the
catchment storage, the dividing line being the inflection point on the recession limb, Fig. 16.9.
t
i
Short rain
Inflection
point
Inflow
of rain
Withdrawal
from storage
Base flow
Time (hr)
D
i
s
c
h
a
r
g
e
,
(
c
u
m
e
c
)
Fig. 16.9 Hydrograph from short rain (IUH)
Assuming that the catchment discharge (O) and the storage (S) are directly propor-
tional
S = KO ...(16.17)
where K = storage coefficient.
From the principle of continuity, if I = inflow resulting from the instantaneous rain
(I O) t = S ...(16.18)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 376
376 HYDROLOGY
or
I I
1 2
2
+
t
O O
1 2
2
+
t = S
2
S
1
...(16.19)
and S
1
= KO
1
, S
2
= KO
2
and hence, O
2
= C
0
I
2
+ C
1
I
1
+ C
2
O
1
...(16.20)
where C
0
=
0 5
0 5
.
.
t
K t +
, C
1
=
0 5
0 5
.
.
t
K t +
, C
2
=
K t
K t

+
0 5
0 5
.
.
...(16.20a)
which are same as Eqs. (9.12 a, b, c) with Muskingum approach, putting x = 0.
and when a sub-area distribution or time-area graph is used and I
1
= I
2
, hence
O
2
= CI + C
2
O
1
...(16.21)
where C =
t
K t + 0 5 .
, C + C
2
= 1
From Eq. (16.18), I O =
dS
dt
3 S = KO,
dS
dt
= K
dO
dt
K
dO
dt
= I O
Using the condition O = 0, when t = 0, the equation can be solved as
O = I(1 exp ( t/K)) ...(16.22)
Since the inflow ceases at the inflection point at time t
i
, the outflow at time t (in terms
of the outflow O
ti
at t
i
) is given by
Q
t
= O
ti
exp
F
H
G
I
K
J
t t
K
i
Storage coefficient K can be determined from an observed hydrograph by noting two
values of O, unit time apart at the point of inflection (Fig. 16.10).
A
1
t
i
Direct
runoff
time (t)
O
D
i
s
c
h
a
r
g
e
,
c
u
m
e
c
A = K (O O )
1 2
Inflexion point
O = O
1 ti
O = O
2 ti + 1
O = O
t ti
t t
K
i

Fig. 16.10 Determination of storage coefficient


O
1
= O
ti
and O
2
= O
ti
exp
F
H
G
I
K
J
t t
K
i
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 377
MATHEMATICAL MODELS IN HYDROLOGY 377
the shaded area A =
t
t
i
i
+
z
1
O
ti
exp
F
H
G
I
K
J
t t
K
i
= KO
ti
exp
F
H
G
I
K
J
O
Q
P
t t
K
i
0
1
= KO
ti
O
ti
exp

F
H
G
I
K
J
1
K
A = K(O
1
O
2
) ...(16.23)
Another observation that is to be made is the catchment lag (t
i
), i.e., the maximum
travel time through the catchment. This may be taken as the time from the mass centre of the
causative rain (flash storm or short rainburst to minimise error) to the inflection point on the
recession limb.
The catchment is subdivided into isochrone such that the rain falling in any sub-area
has the same time of travel to the outflow point O, (Fig. 16.11). The time-area graph (I) now
has instantaneous unit rain applied to it and is routed through to obtain the outflow (O), Eq.
(16.21). This outflow represents the IUH for the catchment and may be converted, if required
to a t
r
-hr unit hydrograph.
1
2
3
4
5 6
7
8
9
Isochrones
Catchment boundary
A = 1040 km
2
t = 9 hr
K = 8 hr
i
0
Fig. 16.11 Catchment divided into isochrones
This method is simple and the design rain can be applied directly to the time-area graph,
with areal variation and with any desired intensity.
An estimate of K can also be had from data on the recession limbs of the basin
hydrographs.
Example 16.1 A catchment of area 1040 km
2
is divided into 9-hourly divisions by isochrones
(lines of equal travel time) in Fig. 16.11. From the observation of a hydrograph due to a short
rain on the catchment, t
i
= 9 hr and K = 8 hr. Derive: (a) the IUH for the catchment. (b) a 3-hr
UG.
Solution (i) It will be assumed that the catchment is divided into sub-areas such that all
surface runoff from each of these areas will arrive during a 1-hr period at the gauging point.
The areas are measured by planimetering each of the hourly areas as:
Hour: 1 2 3 4 5 6 7 8 9
Area (km
2)
: 40 100 150 180 160 155 140 80 35
(ii) The time-area graph (in full lines) and the distribution graph of runoff (in dotted
lines) are drawn as shown in Fig. 16.12. The dotted lines depict the non-uniform areal distri-
bution of rain.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 378
378 HYDROLOGY

0
.8
8
2

0
.8
8
2

0
.8
8
2
0 1 2 3 4 5 6 7 8 9
200
180
160
140
120
100
80
60
40
20
0
Time (hr)
A
r
e
a
,
(
k
m
2
)
Fig. 16.12 Time-area graph for catchment
Table 16.1 IUH by routing and derivation of 3-hr UG (Example 16.1)
Time Time-area 0.1177 I = 2.78 0.882 col (5) O
2
= IUH 3-hr UGO
(hr) diagram 0.1177 previous (cumec) = col (3) (cumec)
Area (km
2
) col (2) (cumec) + col (4)
(cumec)
1 2 3 4 5 6
0 0 0 0 0 0
1 40 13.1 0 13.10
2 100 32.7 11.54 44.24
3 150 49.1 39.00 88.10 44.00
4 180 58.9 77.70 136.60
5 160 52.3 120.40 172.70
6 155 50.7 152.00 202.70 145.40
7 140 45.8 179.00 224.80
8 80 26.2 197.00 223.20
9 35 11.4 196.50 208.00 205.30
10 0 0 184.50 184.50
11 0 0 163.70 163.70
12 0 0 145.00 145.00 176.50
13 0 0 128.60 128.60
14 0 0 114.00 114.00
15 0 0 101.00 101.00 123.00
Plot col (1) vs. col (5) to get the IUH, and col (1) vs. col (6) to get the 3-hr UGO, as shown
in Fig. 16.13.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 379
MATHEMATICAL MODELS IN HYDROLOGY 379
(iii) From Eq. (16. 21), O
2
= CI + C
2
O
1
C =
t
K t + 0 5 .
=
1
8 0 5 1
1
8 5 +
=
. .
= 0.1177
C
2
=
K t
K t

+
=

+
=
0.5
0.5
8 0.5 1
8 0.5 1
7.5
5
= 0.882, Check: C + C
2
= 1
Hence, the routing equation becomes
O
2
= 0.1177 I + 0.882 O
1
O
2
vs. time gives the required synthetic IUH from which the 3-hr UGO are obtained as
computed in Table 16.1. The conversion constant for Col (3) is computed as
1-cm rain on 1 km
2
in 1 hr =
10 10
3600
6 2

= 2.78 m
3
/s
The 3-hr UGO is obtained by averaging the pair of IUH ordinates at 3-hr intervals and
writing at the end of the intervals.
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Time (hr)
240
220
200
180
160
140
120
100
80
60
40
20
0
3-hr UG (by
averaging IUHO)
IUH
derived
D
i
s
c
h
a
r
g
e
(
c
u
m
e
c
)
Fig. 16.13 IUH derived and 3-hr UG (Example 16.1)
16.3 SYNTHETIC STREAM FLOW
The probability of occurrence of floods or droughts are more severe than that observed from
the available stream flow records has to be known. On the assumption that the streamflow is
essentially a random variable, it is possible to develop a synthetic flow record by statistical
methods.
It has been found that high flows are likely to follow high flows and the low flows follow
low flows, i.e., any event is dependent on the preceding event. This persistence is measured by
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 380
380 HYDROLOGY
a serial lag coefficient. The lag interval may be one or several time units. A simple one lag
Markov generating equation for annual flows Q is
Q
i
=
Q
+ r
i
(Q
i1

Q
) +
i
1
2
r
i
...(16.24)
where = standard deviation of Q
Q
= mean of Q
i = 1 year to n year (flows in series)
r
i
= lag-1 Markov coefficient, which is a portion of the departure from the previous flow
from the mean.
The Eq. (16.25) yields a normal synthetic flow that preserves the maximum variance,
and first-order-correlation coefficient of the observed record. Statistical streamflow models
are assumed stationary, i.e., the mean and variance of the observations (time series) are un-
changed with time.
Thomas and Fiering (1962) used the Markov Chain model for generating monthly flows
(by serial correlation of monthly flows) by using the following recursion equation.
q
i+1
= q
j +1
+ b
j
(q
i
q
j
) +
i

j+1
1
2
r
j
...(16.25)
where q
i
, q
i + 1
= discharges in the i and i + 1 months, respectively
q
j
, q
i +1
= mean monthly discharges in the j and j + 1 months of the annual cycle
b
j
= regression coefficient for estimating the discharge in the j + 1 month from
that in the j month

i
= a random normal deviate at time i with a zero mean and unit variance.

j + 1
= standard deviation of discharges in the j + 1 month
r
j
= correlation coefficient between the discharges in the j and j + 1 months.
The Eq. (16.25) is called Lag-one single period Markov Chain Model, where the period
may be day, month or year.
To reflect different seasonal or monthly means, the multi-period Markov model is used,
which requires a double indexing subscript as (using Q for annual flows)
Q
i, j
= Q
j
+ b
j
(Q
i1,

j1

Q
j 1
) +
i

j
1
2
r
j
...(16.26)
where b
j
= r
j

j
j
F
H
G
I
K
J
1
, since Q
j +1
Q
j
...(16.26a)
j = number of seasonal periods or months in the year and other terms have been defined
in Eq. (16.25) in which q = Q for annual flows.
This model has been used extensively in stream flow analysis. The single-and multi-
period Markov generation procedures sometimes result in negative flows. These flows must be
retained for generating the next flows in sequence and then they may be discarded.
The procedure assumes that the discharges (or their transform) are normally distrib-
uted. A synthetic flow record generated like this can be of any desired length and may well
include flow sequences more critical than any in the available observed record. Stochastic
analysis can be used to generate a number of synthetic-flow traces of length equal to the ex-
pected useful life of project under study.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 381
MATHEMATICAL MODELS IN HYDROLOGY 381
Stochastic methods may be employed to generate a synthetic record of rainfall, which
could be transformed to streamflow (by doing a particular operation), which the available
streamflow records are found too short for a stochastic generation. The Markov process for
generating a sequence of rainfall data is given by the relation
P (X
t + 1
= j|X
t
= i) . ..(16.26b)
which expresses the conditional probability of transitioning from the state i at period t to
state j at (t + 1).
Matalas (1967) used a simple matrix representation of the problem, similar to the
Markovian model, as
X
t + 1
= AX
t
+ B
t + 1
...(16.27)
where X
t
= n 1 matrix representing the non-autocorrelated standardised flow at n stations
at time t
X
t + 1
= a similar matrix as above at time (t + 1)

t + 1
= n 1 matrix of non-autocorrelated random numbers with zero mean and unit
variance
A, B = n n matrices, the elements being so chosen as to preserve time mean q , vari-
ance
2
, lag 1-serial correlation coefficient r and the cross correlation coefficients r
nm
between
all the data elements being modelled.
Data generated by models can be used to design reservoir capacity by using low-flow-
frequency mass diagram and other techniques. Several hundred years of records are gener-
ated to obtain an adequate number of high-and low-flow sequences.
16.4 FLOW AT UNGAUGED SITES BY MULTIPLE REGRESSION
At sites where streamflow records are not available, the flow can be estimated by a multiple-
regression technique using the drainage basin and climatic characteristics as independent
variables. The regression constant and coefficient are calculated using streamflow data from
gauged streams. By expressing the variables in common logarithms, the equation can be trans-
formed to the linear form as
log Q = a + b
1
log x
1
+ b
2
log x
2
+ ... + b
n
log x
n
...(16.28)
where Q = annual or monthly peak flow or runoff volume with any assigned probability and
duration; the dependent variable, cumec.
a = regression constant
x = an independent variable characteristic of a drainage basin or its climatic factor
b = the regression coefficient for x
Twenty or more sets of data are required to obtain reliable values of the regression
constant and coefficients by solving Eq. (16.28), which is usually done by the use of a computer.
16.5 RESERVOIR MASS CURVE
A mass curve (or Rippl diagram, 1882) is a cumulative plotting of net reservoir inflow (Fig. 16.14),
and is expressed as
V(t) =
0
t
z
Q(t)dt ...(16.29)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-1.PM5 382
382 HYDROLOGY
where V(t) = volume of runoff
Q(t) = reservoir inflow
both as functions of time
D
C
Ave. rate
of flow =
X
t t
2 1
X
V = shaded area above
t
b. Flow mass curve
(Rippls curve, 1882)
Rotate AB
to horizontal
for residual
mass curve
t
1
t
2
t
Time t (hr)
Time t (hr)
V
t
t
a. Hydrograph of
river inflow
B
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
V
(
h
a
-
m
)
c. Residual mass curve
Range R
Normal line B A

+
Time t (hr)
D
e
p
a
r
t
u
r
e
s
f
r
o
m
n
o
r
m
a
l
(
h
a
-
m
)
+

Fig. 16.14 Flow and residual mass curves


The instantaneous rate of flow at any point on the mass curve is given by the slope of the
tangent at the point, i.e.
Q(t) =
dV t
dt
( )
...(16.29a)
As already discussed, the mass curve has many useful applications in the design of a
storage reservoir, such as determination of reservoir capacity, operations procedure and flood
routing.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 383
MATHEMATICAL MODELS IN HYDROLOGY 383
16.6 RESIDUAL MASS CURVE
Instead of plotting a mass curve, the departure of the mass curve from the normal (AB) may be
plotted against time. In other words, the mass curve is plotted about a horizontal axis obtained
by rotating the average slope line AB of the mass curve, to the horizontal (Fig. 16.14 (c)). Such
a plot is called a residual mass curve. This method of plotting saves the additional space
needed for plotting a continuously rising mass curve and to accentuate more clearly the crests
and troughs of the cumulative flow records.
The difference between the maximum and minimum values of a residual mass curve for
a given period n is known as the range for the period n. If R is the range of a period of n
years of annual-runoff record-whose sample standard deviation is , then according to Hurst
(1951, 1956) and Klemes (1974)
R =
n
k
2
F
H
G
I
K
J ...(16.30)
where k varies from 0.5 to 1 with an average value of 0.73. Here R will be the required storage
if a steady discharge equal to the mean over a period of n years is to be produced. Theoreti-
cally, it can be shown that if the runoff record is a normally distributed random time series,
then
R = 1.25
p
n ...(16.31)
where
p
= the population standard deviation.
16.7 SELECTION OF RESERVOIR CAPACITY
The determination of the required capacity of a storage reservoir is usually called an opera-
tion study using a long-synthetic record. An operation study may be performed with annual,
monthly, or daily time intervals; monthly data are most commonly used.
When the analysis involves lengthy synthetic data, a computer is used and a sequent-
peak algorithm is commonly used. Values of the cumulative sum of inflow minus withdrawals
taking into account the precipitation, evaporation, seepage, water rights of the downstream
users, etc., are calculated, (Fig. 16.15). The first peak and the next following peak, which is
greater than the first peak, i.e., the sequent, peak, are identified.
Time (months)
Sequent peaks
Max
storage
Storage
Initial peak
S
(
I
n
f
l
o
w

D
e
m
a
n
d
)
,
(
1
0
0
0
h
a
-
m
)
0
+
v
e

v
e
Fig. 16.15 Sequent-peak algorithm
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 384
384 HYDROLOGY
The maximum difference between this sequent peak and the lowest trough during the
period under study is taken as the required storage capacity of the reservoir.
Example 16.2 The mean monthly flow data for a proposed reservoir site are given be-
low:
Month Jan. Feb. Mar. April May June
Mean monthly flow (cumec) 6 3 1 2 7 1
Month July. Aug. Sept. Oct. Nov. Dec.
Mean monthly flow (cumec) 27 29 30 27 31 15
Determine the average discharge that can be expected throughout the year. Draw the
residual mass curve and obtain an expression for the range as developed by Hurst on the basis
of the monthly flow data.
Solution
Mean Monthly Cumulative Cumulative Residual
monthly flow volume mothly mean flow mass curve
Month flow, x (ha-m) inflow (ha-m) throughout (ha-m)
(cumec) the year (ha-m)
1 2 3 4 5 6
Jan 6 1575 1575 3931 2356
Feb 3 790 2365 7862 5497
Mar 1 262 2627 11793 9166
April 2 525 3152 15725 12573
May 7 1840 4992 19656 14664
June 1 262 5254 23587 18333
July 27 7100 12354 27518 15164
Aug 29 7750 20104 31450 11346
Spet 30 7880 27984 35381 7397
Oct 27 7100 35084 39312 4228
Nov 31 8150 43234 43243 0009
Dec 15 3940 47174 47174 0
n = 12 179 47174
x =
179
12
= 15 cumec
Mean flow (per month)
throughout the year
47174
12
= = 3931.2 ha-m
The average discharge that can be expected throughout the year
Q =
47174 10
365 86400
4 3

m
S
= 15 cumec = x
The residual mass curve is plotted in Fig. 16.16 and the range, R = 18333 ha-m, which
is the storage capacity of the reservoir to maintain the mean flow of 15 cumec throughout the
year.
x: 6 3 1 2 7 1 27 29 30 27 31 15
x x : 9 12 14 13 8 14 12 14 15 12 16 0
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 385
MATHEMATICAL MODELS IN HYDROLOGY 385
(x x )
2
: 81 144 196 169 64 196 144 196 225 144 256 0
(x x )
2
= 1815
=
( ) x x
n

2
1
1815
12 1
= 12.84 cumec
Let R =
n
k
2
F
H
G
I
K
J
18333 10
4
= 12.84 (30.4 24 60 60)
12
2
F
H
G
I
K
J
k
6
k
=
18333 10
3370 10
4
4

= 5.44
k = 0.945
J F M A M J J A S O N D Months
Storage for
Q = 15 cumec
throughout year
Residual
mass curve
Range, R
= 18333 ha-m =
6
4
2
0
2
4
6
8
10
12
14
16
18
20
(

)
(
+
)
R
e
s
i
d
u
a
l
m
a
s
s
i
n
(
1
0
0
0
h
a
-
m
)
Fig. 16.16 Residual mass curve (Example 16.2)
Thus, the expression for range (on the basis of 12 months data) is
R =
n
2
0.945
F
H
G
I
K
J ...(16.32)
Usually k varies from 0.5 to 1.0, the average value being 0.73. Usually, a number of
years of observation are required.
Example 16.3 Given in Table 16.2 (Col. 1, 2, 3, 5 and 6) are the monthly inflows during low-
water period at the site of a proposed dam, the corresponding monthly precipitation and pan
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 386
386 HYDROLOGY
evaporation at a nearby station, and the estimated monthly demand for water. Prior water
rights downstream require a special release of 6 cumec or the natural inflow, whichever is less.
Assuming that only 24% of the rainfall on the land area to be flooded by the proposed reservoir
has reached the stream in the past, reservoir area as 6000 ha on an average, and a pan coefficient
of 0.7, construct the sequent peak alogrithm and determine the required storage capacity of the
reservoir.
Solution Since 24% of the rainfall (P) is runoff, which is already included in the monthly
inflows into the reservoir, only 100 24 = 76% of the rainfall on the reservoir area is to be
included. Reservoir evaporation = 0.7 pan evaporation (E
P
). (0.76P 0.7 E
p
) values have to
be multiplied by the average reservoir area at the beginning and end of each month.
The monthly change in storage and cumulative storage (at the end of each month) are
worked out in Table 16.2 and the sequent peak algorithm is drawn as shown in Fig. 16.17 and
the required storage capacity of the Reservoir (difference between the initial peak and the
lowest trough in the interval) is 13045 ha-m, which is also indicated in the col. (10) of Table
16.2. Actually this process has to be done for 4-5 consesecutive years and the difference be-
tween the highest peak and the suceeding lowest trough gives the required storage
capacity to meet the specified demand. The required storage capacity is also equal to the sum
of the negative quantities (Deficit) in Col (8) of Table 16.2, which is less than the sum of the
positive quantities (Surplus) col (8), thus ensuring the filler of the reservoir during mon-
soons.
July A S O N D J F M A M June
=
Reservoir
storage
13045
ha-m
Trough
Peak
Time months
24
20
16
12
8
4
0
4
8
12
16

v
e
+
v
e
S
(
I
n
f
l
o
w

D
e
m
a
n
d
)
(
1
0
0
0
h
a
-
m
)
Fig. 16.17 Sequent-peak Algorithm (Example 16.3)
16.8 FLOOD FORECASTING
With the operation of flood forecasting centres in India since 1969, heavy loss of life and suffer-
ing of people are greatly minimised due to advance warning. In the country, there are 8 fore-
casting centres with 25 sub-centres and more than 200 observation sites have been equipped
with wireless. In addition to this, rainfall data from 30 ordinary rain gauge stations and 50
self-recording rain gauge stations are also collected to supplement the gauge and discharge
data.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 387
MATHEMATICAL MODELS IN HYDROLOGY 387
T
a
b
l
e

1
6
.
2

O
p
e
r
a
t
i
o
n

s
t
u
d
y

f
o
r

a

s
t
o
r
a
g
e

r
e
s
e
r
v
o
i
r

(
E
x
a
m
p
l
e

1
6
.
3
) U V | | W | | U V | | | | W | | | |
S u r p l u s =
2 2 0 5 1 h a - m
D e f i c i t = 1 3 0 4 5 h a - m
2 2 0 5 1 9 0 0 6
| = 1 3 0 4 5 h a - m |
M
o
n
t
h
M
e
a
n
M
o
n
t
h
l
y
P
r
e
c
i
p
i
P
a
n

E
v
a
-
D
e
m
a
n
d
D
/
s

R
e
l
e
a
s
e
C
h
a
n
g
e

i
n
C
u
m
u
l
a
t
i
v
e
R
e
s
e
r
v
o
i
r
m
o
n
t
h
l
y
f
l
o
w
t
a
t
i
o
n
,
p
o
r
a
t
i
o
n
,
(
h
a
-
m
)
(
h
a
-
m
)
s
t
o
r
a
g
e
,

s
s
t
o
r
a
g
e
,
c
a
p
a
c
i
t
y
f
l
o
w
,

Q
v
o
l
u
m
e
P

(
m
m
)
E
p

(
m
m
)
(
h
a
-
m
)


s
(
h
a
-
m
)
(
c
u
m
e
c
)
(
h
a
-
m
)
=

(
3
)

+

(
4
)

(
h
a
-
m
)
(
5
)
-
(
6
)
-
(
7
)
1
2
3
4
5
6
7
8
9
1
0
J
u
l
y
2
7
6
9
9
8

1
3
5
1
5
5
6
5
0
1
5
5
5

+
4
7
5
8
*
4
7
5
8
A
u
g
.
2
9
7
2
5
7
1
7
5
7
5
9
7
5
1
5
5
5
+
5
2
1
0
9
9
6
8
S
e
p
t
.
3
0
7
7
7
6
1
4
0
8
0
1
2
0
0
1
5
5
5
+
5
0
7
1
1
5
0
3
9
O
c
t
.
2
7
6
9
9
8
2
5
1
2
5
1
7
5
0
1
5
5
5
+
3
2
8
2
1
8
3
2
1
N
o
v
.
3
1
8
0
3
5
5
6
5
2
5
0
0
1
5
5
5
+
3
7
3
0
2
2
0
5
1
D
e
c
.
1
5
3
8
8
8
0
4
0
2
5
0
0
1
5
5
5

3
3
5
2
1
7
1
6
J
a
n
.
6
1
5
5
5
0
5
0
2
5
0
0
1
5
5
5

2
7
1
0
1
9
0
0
6
F
e
b
.
3
7
7
7
0
8
0
2
4
0
0
7
7
7

2
7
3
6
1
6
2
7
0
M
a
r
c
h
1
2
5
9
0
1
0
0
2
2
5
0
2
5
9

2
6
7
0
1
3
6
0
0
A
p
r
i
l
2
5
1
8
2
0
1
3
0
1
5
0
0
5
1
8

1
9
5
5
1
1
6
4
5
M
a
y
7
1
8
1
4
4
5
1
9
5
1
2
5
0
1
5
5
5

1
6
0
5
1
0
0
4
0
J
u
n
e
1
2
5
9
1
0
0
2
0
0
6
5
0
2
5
9

1
0
3
4
9
0
0
6
1
3
0
4
5
1
.

2
7

c
u
m
e
c


3
0

d
a
y
s

=

2
7
(
3
0


8
6
4
0
0
)
/
1
0
4

=

6
9
9
8

h
a
-
m
2
.

5
6

c
u
m
e
c


3
0

d
a
y
s

=

6

(
3
0


8
6
4
0
0
)
/
1
0
4

=

1
5
5
5

h
a
-
m
3
.

*
6
9
9
8

+

1
3
5
0
.
7
5
1
5
5
0
.
7
1
0
0
0


6
0
0
0


6
5
0


1
5
5
5

=

+
4
7
5
8

h
a
-
m
4
.

R
e
s
e
r
v
o
i
r

c
a
p
a
c
i
t
y

=

s
u
m

o
f

n
e
g
a
t
i
v
e

q
u
a
n
t
i
t
i
e
s

i
n

c
o
l
.

(
8
)
.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 388
388 HYDROLOGY
Factors governing forecasting can be divided into two groupsinitial and final. The
initial factors govern conditions existing at the time when the forecast is made and can be
estimated on the basis of current hydrometeorological observations. The final factors include
the future weather conditions and has to be taken into account in hydrological forecasts, if an
accurate weather forecast is available. In practice, short-term forecasts of weather elements
are being used in compilation of hydrological forecasts and warnings.
The elements of forecasts include forecast of crest stages, discharge and time of occur-
rence, etc. In some cases, the other basic water regime elements to be known are:
(i) volume of runoff in respect of various periods of time
(ii) flow distribution
(iii) MWL in reservoir and the data of occurrence
The data required for making an accurate forecast are:
(a) stage and discharge of upstream base station
(b) stage and discharge of forecasting station
(c) change in stage and discharge of these stations
(d) stage and discharge of any tributary joining the main stream between the base sta-
tion and forecasting site
(e) the intensity, duration and distribution of rainfall in the main, intercepted or sub-
catchment
(f) topography, nature of vegetation, soil type, land use, population density, depth of
GWT etc., of the main or intercepted catchment
(g) the atmospheric and climatic conditions.
The factors (a) to (d) are the basic parameters used in developing correlation curves or
mathematical models; factor (d) can be neglected if its contribution is not appreciable, and
factors (e) and (f) are taken into account for introducing rainfall and antecedent precipitation
index as additional parameters; however, (g) stands as a future factor.
The forecasing methods currently used in the country are:
(a) based on laws governing the movement of water in the channel, i.e., using the hydro-
dynamic methods to determine the movement and transformation of flood waves
(b) based on the analysis of hydrometerological data of the river basin, i.e., water balance
studies taking into account precipitation, the water equivalent of snow cover, soil moisture,
ground water and other factors and estimating runoff, which require the use of a computer.
For small catchments, approximate calculations of flood movement and transformation
can be made by:
(i) multiple correlation between stage and discharge observations
(ii) streamflow routing on river reaches
(iii) mathematical model
Multiple correlation has the advantage of using parameters like rainfall or antecedent
precipitation index. Streamflow routing method includes the effect of channel storage on the
shape and movement of flood wave; Muskingum method is generally used. For example, the
routing equation developed between Sikanderpur and Rossera on Burhi Gandak (Bihar) is
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 389
MATHEMATICAL MODELS IN HYDROLOGY 389
O
2
= 0.612I
1
+ 0.033I
2
+ 0.355O
1
...(16.33)
where K = 36 hr, x = 0.3 and t = 24 hr
16.8 MATHEMATICAL MODEL
A linear reservoir attenuates the peak of an inflow hydrograph and a linear channel translates
inflow hydrograph in time, which are representative of the physical action performed by the
catchment. Hence, a model of a linear reservoir connected in series with a linear channel may
be selected in this study. A linear channel is defined by the delay time or the time of travel of
the flood wave and is approximately determined with the help of time to peaks of flood events
on the upstream and downstream stations of a river reach. Muskingum equation defines the
linear reservoir by its storage-discharge relation as
S = K[xI + (1 x)O] ...(16.34)
From the principle of continuity
I O =
dS
dt
or S
2
S
1
=
I I
t
O O
1 2 1 2
2 2
+ F
H
G
I
K
J

+ F
H
G
I
K
J t ...(16.35)
From Eq. (16.34) S
1
= K[xI
1
+ (1 x)O
1
]
S
2
= K[xI
2
+ (1 x)O
2
]
S
2
S
1
= K[x(I
2
I
1
) (1 x)(O
2
O
1
)] ...(16.36)
From Eqs. (16.35) and (16.36),
O
2
= C
0
I
2
+ C
1
I
1
+ C
2
O
1
...(16.37)
where C
0
=
Kx t
K Kx t

+
0 5
0 5
.
.
, C
1
=
Kx t
K Kx t
+
+
0 5
0 5
.
.
C
2
=
K Kx t
K Kx t

+
0 5
0 5
.
.
...(16.37a)
and C
0
+ C
1
+ C
2
= 1
The routing period t (time interval between O
1
and O
2
) should be equal to or less than
the time of travel through the reach.
Eq. (16.37) for successive time intervals may be written as
O
3
= C
0
I
3
+ C
1
I
2
+ C
2
O
2
...(16.38)
O
4
= C
0
I
4
+ C
1
I
3
+ C
2
O
3
...(16.39)
Eq. (16.38) (16.37) gives:
O
3
O
2
= C
0
(I
3
I
2
) + C
1
(I
2
I
1
) + C
2
(O
2
O
1
) ...(16.40)
Eq. (16.39) (16.38) gives:
O
4
O
3
= C
0
(I
4
I
3
) + C
1
(I
3
I
2
) + C
2
(O
3
O
2
) ...(16.41)
Assuming the stage (gauge height)discharge curves as a straight line (as a first ap-
proximation), if the slopes of the curve on upstream and downstream are 1/a and 1/b,
Fig. 16.18 (a) then
I I
H H
a
2 1
2 1
1

= and
I I
H H
a
3 2
3 2
1

=
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 390
390 HYDROLOGY
O O
G G
b
2 1
2 1
1

= and
O O
G G
b
3 2
3 2
1

=
1
a
3
a
2
1
1
a
1
Assumed
rating
curve
Actual
rating
curve
H Upstream gauge
Inflow I (cumec)
S
t
a
g
e
H
(
m
)
Outflow O (cumec)
S
t
a
g
e
G
(
m
)
b
1
1
b
2
1
b
3
1
Assumed
rating curve
Actual
rating curve
G Downstream gauge
O
1
O
2
O
3
O
4
Outflow O (cumec)
G
1
G
2
G
3
G
4
S
t
a
g
e
(
m
)
Assumed
rating curve
G Downstream
gauge
Actual rating
curve
b
1
G G
2 1
O O
2 1
1
b
=
H Upstream gauge
Actual rating
curve
Assumed
rating curve
Slope
1
a
1
a
H
I I
2 1
2 1
H 1
a
=
I
1
I
2
I
3
H
1
H
2
H
3
Inflow (cumec) I
S
t
a
g
e
(
m
)
a. Stage discharge rating curves assumed linear
b. Stagedischarge curves divided into three linear parts
Fig. 16.18 Stage-discharge-rating curves Assume
Substituting these in Eq. (16.40)
b(G
3
G
2
) = C
0
a(H
3
H
2
) + C
1
a(H
2
H
1
) + C
2
b(G
2
G
1
)
or G
3
G
2
= C
2
(G
2
G
1
) + C
0
a
b
(H
3
H
2
) + C
1
a
b
(H
2
H
1
) ...(16.42)
Similarly, substitution in Eq. (16.41) gives
G
4
G
3
= C
2
(G
3
G
2
) + C
0

a
b
(H
4
H
3
) + C
1

a
b
(H
3
H
2
) ...(16.43)
Eqs. (16.42) and (16.43) may be written as
G
3
G
2
= x
1
(G
2
G
1
) + x
2
(H
2
H
1
) + x
3
(H
3
H
2
)
G
4
G
3
= x
1
(G
3
G
2
) + x
2
(H
3
H
2
) + x
3
(H
4
H
3
)
where x
1
= C
2
, x
2
= C
1

a
b
, and x
3
= C
0

a
b
Thus, a number of equations can be obtained from the observed data and solved for x
1
,
x
2
and x
3
by the least square technique. Since the number of such equations are very large,
from large sets of data, a computer can be used. For example, the equations developed for a
straight reach between Muzaffarpur and Rossera on Burhi-Gandak are
Rising stage:
G
3
G
2
= 0.401 (G
2
G
1
) + 2.826 (H
2
H
1
) 0.94 (H
3
H
2
) ...(16.44)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 391
MATHEMATICAL MODELS IN HYDROLOGY 391
Falling stage:
G
3
G
2
= 0.1413(G
2
G
1
) + 0.3018(H
2
H
1
) + 0.6082(H
3
H
2
) ...(16.45)
As a further refinement the stage discharge curves may be divided into linear parts, say
three, and the slopes denoted according to the linear ranges in which the stages lie, as shown
in Fig. 16.18 (b), and the equations solved by using multiple regression technique.
Contribution due to a major tributary between the base station and the forecasting
station has to be taken into account.
The results of flood routing between Sikanderpur (Muzaffarpur) and Rossera by differ-
ent methods during the 1975 floods are given in Table 16.3 for comparison. It can be seen that
the Muskingum method has given more consistent results. A clear picture of forecast and
comparison with past values have been found possible only in graphical correlation and minor
adjustment based on experience can be done in the predicted value. These are not possible in the
mathematical model and also the model cannot give better results in rivers having large scale
fluctuations due to existance of control structures, their operation or flashy nature of the stream.
Contribution due to Tributary
Contribution due to a major tributary between the base station and the forecasting station has
to be taken into account. For example, three major tributaries of Ganga affect the gauge down-
stream at Patna, other than its own (Fig. 16.19).
Table 16.3 Comparison of flood forecast results
Date Time Level Level downstream (m)
(hr) upstream Date Time Graphi- Musk in- Mathe- Observed
(m) (hr) cal cor- gum matical
relation method model
29.7.1975 0800 42.298 30.7.1975 0800 42.750 43.000 43.038 42.900
30.7.1975 0800 42.903 31.7.1975 0800 43.600 43.750 43.527 43.623
31.7.1975 0800 43.583 01.8.1975 0800 44.480 44.750 44.676 44.723
01.8.1975 0800 44.773 02.8.1975 0800 45.320 45.100 45.139 44.583*
*The large variation in the last observation is due to number of breaches in the embankment
between Muzaffarpur and Rossera.
T
r
i
b
u
t
a
r
y
1
T
r
ib
u
t
a
r
y
2 T
r
ib
u
t
a
r
y
3
R
iv
e
r
G
a
n
g
a
H
I
I, H
Upstream
I , H
I, H
O, G
Downstream
gauge (at Patna)
Fig. 16.19 Tributary effect on gauge downstream
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD16-2.PM5 392
392 HYDROLOGY
In such a case, the modified Muskingum equation can be written as
O
2
= C
2
O
1
+ C
1
I
1
+ C
1
I
1
+ C
1
I
1
+ C
1
I
1
+ C
0
I
2
+ C
0
I
1

+ C
0
I
2
+ C
1
C
2
...(16.46)
Similarly, O
3
can be written and O
3
O
2
can be evaluated. Aproximating, its stage (gauge
height)-discharge curve, to a straight line, the ultimate equation will be of the form (writing
G
3
G
2
as G
3.2
and so on)
G
3.2
= x
1
G
2.1
+ x
2
H
2.1
+ x
3
H
3.2
+ x
4
H
2.1
+ x
5
H
3.2
+ x
6
H
2.1
+ x
7
H
3.2
+ x
8
H
2.1
+ x
9
H
3.2
...(16.47)
Number of equations have been formed like this from the observed data and solved for
the constants by the least square technique by using a computer. The constants obtained for
the forecasting site at Patna for the 1975 floods are given in Table 16.4, and the levels reached
in Table 16.5 (compared with values obtained by graphical correlation, which has given better
results).
Table 16.4 Constants for forecasting site at Patna
Constant Rising stage Falling stage
x
1
0.5393 0.2622
x
2
0.1407 0.2783
x
3
0.0919 0.0575
x
4
0.1855 0.2783
x
5
0.1132 0.0427
x
6
0.0608 0.0535
x
7
0.1271 0.0361
x
8
0.0080 0.0196
x
9
0.1192 +0.2002
Table 16.5 Flood forecast results at Patna during 1975
Date Time Level Level downstream (m)
(hr) upstream Date Time Graphical Mathe- Observed
(m) (hr) correlation matical
model
22.8.1975 0900 48.799 23.8.1975 0900 49.429 49.299 49.449
23.8.1975 1700 48.679 24.8.1975 1700 49.929 50.089 49.969
24.8.1975 0100 49.859 25.8.1975 0100 49.929 55.089 49.989
09.9.1975 0900 49.519 10.9.1975 0900 48.809 48.774 48.794
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
17.1 IUH FOR A BASIN
An IUH is a direct-runoff hydrograph producing a unit rainfall excess (P
net
= 1 cm) precipitat-
ing instantaneously over the catchment; i.e., i =
1
t
r
, t
r
0; i increases and the UG becomes
more skewed, called IUH, Fig. 16.6 (b). The shape of the IUH resembles a single peaked
hydrograph. The properties of the IUH are given by Eq. (16.9); and its time to the peak < time
to the centroid of the curve. The main advantage of IUH is that it eliminates the problem of
unit duration and restriction of uniform distribution of rainfall in time. It is independent of
the duration of the rainfall excess (t
r
) and rainfall characterstics, and is indicative of the catch-
ment storage characterstics (like length, shape, slope and storage coefficient), which makes it
eminently suitable for theoretical analysis of rainfall-runoff relationship. The IUH is a unique
demonstration of a particular catchment response to rain, i.e., impulse response. As the IUH
is only an extension of the unit hydrograph concept, it is also based on the principles of liniarity
and time invariance.
If the IUH of a basin is available, the application of Eq. (16.8) yields the direct runoff
due to any storm.
17.2 DERIVATION OF IUH
The IUH can be approximately derived from the S-curve, Eq. (16.7), i.e.,
The ordinate of the IUH at any time t = t
r
Slope of the S-curve derived from the t
r
hr
UG at t, i.e.,
(IUHO)
t
= t
r

S
t
t
F
H
G
I
K
J ...(17.1)
The ordinate of the t
r
-hr UG at any time t =
1
t
r
area of the IUH between (t t
r
) and t
i.e., u
t
=
1
t
r
A
t
...(17.2)
If the IUH is assumed linear between (t t
r
) and t,
u
t
= ( ) IUHO
t
t
r

2
...(17.3)
Chapter 17
393
INSTANTANEOUS UNIT HYDROGRAPH
(IUH)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 394
394 HYDROLOGY
i.e., average of IUHO at t and t t
r
which works well only when t
r
is small and the peak is not contained within the interval (t t
r
)
to t.
Eq. (17.3) can be used to derive a t
r
-hr UG from the available IUH, avoiding the con-
struction of the S-curve hydrograph, see Fig. 16.5.
17.3 OTHER METHODS OF DERIVATION OF IUH
Many researchers have made extensive investigation on the derivation of unit hydrograph
(UG) since Sherman gave the principle of UG in 1932.
The approaches utilised to develop linear conceptual models of rainfall-runoff relation-
ship may be classified into three groups:
The first group employs a differential equation that supposedly governs the equation of
a specified system; input-output relation, with rainfall as input and runoff as output
(Kulandia swamy, Chow1964), see Eq. (16.1).
The second group utilises an arrangement of the so called conceptual elements in-
cluding linear channels and linear reservoirs (Nash 1957), time-area diagrams (Clark 1945),
and geomorphological characterstics (Rodriguez-Iturbe and Valdes, 1979).
The third group makes hypothesis about rainfall-runoff relationship more or less on
intutive grounds (Lienhard).
The practical approaches of Nash and Clark are discussed here and other methods pro-
posed by Dooge, Diskin, etc., are not considered here.
Considerable work has been reported in the literature on the non-linear unit hydrograph
theory, which is beyond the scope of this book.
17.4 NASH CONCEPTUAL MODEL
Nash considered that the IUH can be obtained by routing the instantaneous inflow through a
cascade of linear channels (n numbers) with equal storage coefficient (Fig. 16.7). The out flow
from the first reservoir is considered as inflow into the second reservoir, and so on. The outflow
from the n
th
reservoir yields the IUH given by
u(t) =
1
k n
e
t
k
t
k
n

F
H
G
I
K
J
1
, n = (n 1) ! ...(17.4)
The value of the parameter n, which is a shape parameter, is a measure of the catch-
ment channel storage, which defines the shape of the IUH. A lower value of n yields a higher
peak of IUH because of less storage flow attenuating the peak flow; a higher value of n leads to
a lower peak of IUH signifying higher storage for attenuating peak flow. The parameter K
(delay time, hr), which is a scale parameter, represents the dynamics of rainfall-runoff proc-
ess in the catchment. A smaller K-value reflects a lower time to peak of the runoff hydrograph
and a higher K-value reflects a long time to peak.
The two parameters n and k may be computed by making an analysis of the observed
rainfall-runoff data on the catchment as follows:
The first moment of the IUH about the origin (t = 0): M
1
= nk ...(17.5)
The second moment of the IUH about the origin (t = 0):
M
2
= n(n + 1) k
2
...(17.6)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 395
INSTANTANEOUS UNIT HYDROGRAPH (IUH) 395
By routing through the cascade of n-reservoirs, it can be shown that
MQ
1
MI
1
= nk ...(17.7)
MQ
2
MI
2
= n(n + 1)k
2
+ 2nk MI
1
...(17.8)
where MQ
1
, MQ
2
are the first and second moments of direct runoff about the origin.
and MI
1
, MI
2
are the first and second moments of the effective rainfall (rainfall excess P
net
)
about the origin.
The parameters n and k may be evaluated by solving these two equations as illustrated
in the Example 17.1. Making use of these two parameters an IUH can be derived for a catch-
ment of area eq. A km
2
; and also a t
r
-hr UG, as illustrated in Example 17.2; i.e., from the
available rainfall-runoff data on a catchment of area A, and IUH and a t
r
-hr UG can be de-
rived, for which the procedure involves the steps of both the Examples, 17.1 and 17.2.
Example 17.1 The effective rainfall due to a 4-hr storm in the successive hours are: 2.6, 2.5, 2.3
and 2.4 cm. The resulting DROs in the successive hours are: 3, 15, 26, 40, 50, 35, 25, 20, 15, 10,
7, 4, 3 and 1 cumec. Determine the values of n and k.
Solution
Step 1 Evaluate the first and second moments of P
net
about the origin, i.e., t = 0 (commence-
ment of P
net
and DRO)
MI
1
=
2 6 0 5 2 5 15 2 3 2 5 2 4 3 5
2 6 2 5 2 3 2 4
. . . . . . . .
. . . .
+ + +
+ + +
=
19.2 cm
.
hr
9.8 cm

~

2 hr
MI
2
=
2 6 0 5 2 5 15 2 3 2 5 2 4 3 5
9 8
2 2 2 2
. . . . . . . .
.
+ + +
=
49.75 cm. hr
9.8 cm
2
~_ 5 hr
2
Step 2 Evaluate the first and second moments of Q
i
about the origin;
Q
i
= DRO
i
, Qt = Q
1
t
1
, MQ
1
= t =
Q t
Q
1 1
, Q = Q
1
= DRO
Similarly, Qt
2
= Q
1
t
1
2
; MQ
2
= t
2
=
Q t
Q
1 1
2
Table 17.1 To evaluate MQ
1
and MQ
2
Time DRO
t (hr) (cumec) Q t Q t
2
(given) = Q (cumec-hr) (cumec-hr
2
)
0 0 0 0
1 3 3 3
2 15 30 60
3 26 78 234
4 40 160 640
5 50 250 1250
6 35 210 1260
7 25 175 1225
8 20 160 1280
9 15 135 1215
10 10 100 1000
(Contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 396
396 HYDROLOGY
(Contd.)...
11 7 77 847
12 4 48 576
13 3 39 507
14 1 14 196
15 0 0 0
Q = 254 Qt = 1472 Qt
2
= 102.93
MQ
1
= t =
1472
254
= 5.8 hr, MQ
2
= t
2
=
10293
254
= 40.5 hr
2
Eq. (17.7): nk = MQ
1
MI
1
= 5.8 2 = 3.8 hr
Eq. (17.8): MQ
2
MI
2
= n(n + 1)k
2
+ 2 nk MI
1
40.5 5 = nk
2
(n + 1) + 2 3.8 2
35.5 = n
2
k
2
+ nk
2
+ 15.2
nk
2
= 35.5 15.2 (3.8)
2
= 5.87
k =
nk
nk
2
5 87
3 8
=
.
.
= 1.55
n =
nk
k
=
3 8
155
.
.
= 2.45 ~_ 2 (whole number)
Example 17.2 Derive an IUH and a 2-hr UG (UGO at 2-hr intervals) for a catchment of 240
km
2
, having n = 3 and k = 5 hr.
Solution NASH Model, Eq. (17.4):
u(t) =
1
1
k n
e
t
k
t
k
n

. .

F
H
G
I
K
J
k = 5 hr, n = 3 and n = (n 1) ! = (3 1) ! = 2 ! = 2 1 = 2
u(t) =
1
5 2 5
5
3 1

F
H
G
I
K
J

. . e
t
t
=
1
10 5
5
2
e
t
t F
H
G
I
K
J
/
Table 17.2 IUHO and 2-hr UGO computation
Time IUHO
t(hr)
t
5
e
t
5

t
5
2
F
H
G
I
K
J
u(t) u(t) 2-hr UGO
(cm/hr) (cumec) (cumec)
=
(3) (4)
10

(5) 2.78 240 (by averaging)


= (5) 668
1 2 3 4 5 6 7
0 0 1 0 0 0 0
2 0.4 0.67 0.16 0.0107 7.17
0 7 17
2
+ .
= 3.58
4 0.8 0.45 0.64 0.0288 19.4
19 4 7 17
2
. . +
= 13.3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 397
INSTANTANEOUS UNIT HYDROGRAPH (IUH) 397
6 1.2 0.30 1.44 0.0432 28.8 24.1
8 1.6 0.20 2.56 0.0512 34.2 31.5
10 2.0 0.135 4.00 0.0542 36.2 35.2
12 2.4 0.091 5.76 0.0524 34.9 peak of IUH 35.5 peak of UG
14 2.8 0.061 7.84 0.0480 33.2 34.0
16 3.2 0.041 10.24 0.0420 28.0 30.6
18 3.6 0.027 12.96 0.0350 24.4 26.2
20 4.0 0.0183 16.00 0.0293 19.6 22.0
22 4.4 0.0122 19.36 0.0236 15.7 17.6
24 4.8 0.0082 23.04 0.019 12.7 14.2
26 5.2 0.0055 27.04 0.0149 9.95 11.32
28 5.6 0.0037 31.36 0.0116 7.75 8.85
30 6.0 0.0025 36.00 0.009 6.0 6.87
32 6.4 0.0017 40.96 0.007 4.66 5.33
34 6.8 0.0011 46.4 0.005 3.34 4.00
36 7.2 0.00075 51.8 0.004 2.67 3.00
Nash, from his study on some gauged catchments in UK, established a correlation be-
tween the IUH parameters n and k, and the basin parameters like length of main stream (L,
miles), slope of the basin (S, parts per 1000) and the area (A, sq. miles), as
n = 2.4 L
0.1
, K =
11
0.3
0.1 0.3
A
L S
Using the above relations, the IUH of any ungauged basin in a hydrometeorologically
homogeneous region can be obtained.
17.5 CLARKS MODEL
Clark in 1945, was the first to use the concept of IUH. The clark method requires three param-
eters to calculate IUH: t
c
, the time of concentration for the basin; K, storage coefficient, and a
time-area diagram (TAD).
The value of K is usually obtained by using the slope of the recession curve (which is
negative) at the point of inflection (Fig. 16.10). At the inflection point, the inflow into the
channel has ceased and beyond this point, the flow is entirely due to withdrawal from the
channel storage. From the continuity equation:
I Q =
dS
dt
, Q = O, outflow
I = 0, Q =
dS
dt
, S = KQ
Q = K
dQ
dt
or K =
Q
dQ dt /
...(17.9)
For the recession limb, Fig. 16.10, Q
t
= Q
0
e
t/k
, k =
t
Q Q
t
ln ( / )
0
...(17.9 a)
Clark gave the empirical relation as K =
CL
S
and Linsley further modified this as K =
bL A
S
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 398
398 HYDROLOGY
K in hr, L in miles, A in sq. miles, constants C = 0.8 to 2.2, b = 0.04 to 0.08. The value of
K may be estimated from the above relations in case no hydrograph is available for the basin.
17.6 DRAWING ISOCHRONES AND TIME-AREA DIAGRAM (TAD)
The basin is divided into zones (sub-areas A
r
, km
2
) by drawing isochrones (Fig. 16.11). An
isochrone is a line joining all points having the same travel time. A water particle on a 8-hr
isochrone will take 8 hr to reach the basin outlet.
For drawing the isochrones, the profile of the longest water course (i.e., main water
course) is plotted as elevation vs, distance from the basin outlet. The total length of the main
channel is then divided into N reaches, keeping in mind the slopes in different reaches, since
the time of travel (t) is proportional to L/ S , i.e., t =
KL
S
, where K is the constant of propor-
tionality. Then the elevation of each portion in transferred to the contour map of the catch-
ment.
An initial estimate of the time of concentration (t
c
hr) may be obtained by using Kirpichs
formula (L in km)
t
c
= 0.06628 L
0.77
S
0.385
...(17.10)
and from this the value of K can be determined.
At the points transferred to the contour map, curves are drawn joining all the points
having specified travel times, which are called isochrones. The areas between the successive
isochrones are planimetered and the time-area diagram (TAD) is prepared from the isochronal
map (Fig. 16.12).
17.7 CLARKS METHOD
In the Clarks approach, the ordinates of TAD are converted to volume rate of runoff in cumec
for unit rainfall excess, i.e., 1 cm, occurring instantaneously and uniformly over the
catchment, as
I =
1 10
100 60 60
6
cm( ) A
t
r


= 2.78
A
t
r
cumec or m
3
/s ...(17.11)
where t = Computation time interval, hr of TAD, i.e., isochrone interval or routing period
t
c
= t N, N = No. of inter-isochrone areas or sub areas, A
r
km
2
Catchment are A = A
r
In Example 16.1, t
c
= 1 hr 9 # = 9 hr
~

t
i
, N = 9
Note: 8 Isochrones are drawn to yield 9 zones (N = 9) or Subareas A
r
.
t =
t
N
c
...(17.12)
The inflow (I) from the sub area A
r
calculated as above, i.e., the resulting translation
hydrograph is then routed through a linear reservoir to simulate the storage effects of the
basin; Clarks method utilises Muskingum method of routing through a linear reservoir, i.e.,
x = 0 in Eq. (9.9); S = KQ, Q = O.
The general equations for the linear reservoir is (See Eq. (16.21))
IUHO = O
2
= Q = CI + C
2
O
1
, O
1
= Q
1
i.e., Q
2
= CI + C
2
Q
1
, for IUH derivation ...(17.13)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 399
INSTANTANEOUS UNIT HYDROGRAPH (IUH) 399
The routing coefficients are obtained from (see Eqs. 16.20, 16.20a, 16.21)
C =
t
k t + /2
, C
2
=
k t
k t

+
/
/
2
2
C + C
2
= 1 ...(17.14)
The resulting IUHO (IUH ordinates) are averaged at t
r
intervals to produce a t
r
-hr UG,
Ex. 16.1.
Note: u
t
of t
r
-hr UG = u
t
t
r

F
H
G
I
K
J
2
of IUH =
u u
t t t
r
+

2
of IUH, i.e., by averaging IUHO, assuming linear.
Example 17.3 The recession ordinates of the flood hydrograph (FHO) for the Lakhwar dam
site across river Yamuna are given below. Determine the value of K.
Time (hr): 30 36 42 48 54 60 66 72 78
FHO (cumec): 1070 680 390 240 150 90 45 30 20
Solution Eq. (5.1) can be expressed in an alternative form of the exponential decay as
Q
t
= Q
0
e
t/k
, when K =
t
Q Q
t
ln ( / )
0
Q vs. t is plotted on the semi-log paper (Fig. 17.1). K is the slope of the recession-flood-
hydrograph plot.
2000
500
1100
1000
800:8
6
500:5
4
300:3
200:2
150:1.5
100
8
6
5
4
3
2
1.5
10
0 10 20 30 40 50 60 70 80 90 100 120
10
Time t (hr)
Q
(
c
u
m
e
c
)
31 hr

t
Semi-log paper
Slope
K = =
D
D
t
ln Q
31 59
ln
1000
100
12 hr
100
cumec
1000
One log
cycle
R
e
c
e
s
s
i
o
n
h
y
d
r
o
g
r
a
p
h
O
r
d
i
n
a
t
e
s
(
F
H
O
)
59 hr
28
2.303 log 10
=
~
Fig. 17.1 Recession flood hydrograph
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 400
400 HYDROLOGY
K =

t
Q
t
ln
. log
=
2 303
1000
100
, t = t
1000
t
100
cumec
= 31 hr 59 hr, from the plot
K =
31 59
2 303 1
28
2 303
12 15

= =
. .
. , say 12 hr
Example 17.4 The isochronal map of Lakhwar damsite catchment, Fig. 17.2 (a) has areas
between successive 3 hr isochrones as 32, 67, 90, 116, 135, 237, 586 and 687 km
2
. Taking k = 12
hr (as determined in Ex. 17.3), derive the IUH of the basin by Clarks approach and hence a
3-hr UG.
0 3 6 9 12 15 18 21 24
Time (hr)
(b) Time-area diagram (TAD)
A
1
A
2
A
3
A
4
A
5
A
6
A
7
A
8
t = t
= 3 hr
c

t 8 = 24
# hr
A ll
t
c
r
c

700
600
500
400
300
200
100
I
n
t
e
r
-
i
s
o
c
h
r
o
n
e
a
r
e
a
A
(
k
m
r
2
)
Remote
end
t = 24 hr
c
2
1
h
r
7
2
1
h
r
Hanuman
A Ganga
8
R
.Y
a
m
u
n
a
A7
Bhadri Gad
A
4
A
5
A
6
A
3
A
2
A
1
Basin
boundary
6
5
1
2
h
r
-
4
9
h
r
-
3
6
h
r
-
2 3
h
r
-
1
L
a
k
h
w
a
r
D
.S
.
R.Yamuna
Basin outlet
Mussorie
9
h
r
1
2
h
r
1
5
h
r
1
8
h
r
(a) Isochronal map of Lakhwar
DS Catchment.
3 hr-Isochrones, 7 #
subareas: A -A
1 8
A = A = 1950 km
t = 24 hr, t = t = 3 hr
S
r
c c
2

8
1
3 hr 8 # = 24 hr
= t

c
Fig. 17.2 Isochrones and TAD for Lakhwar Dam Site
Solution
Note A = A
r
= 1950 km
2
t
c
= t N = 3 8 = 24 hr, K = 12 hr
No. of isochrones = N 1 = 8 1 = 7#
Computation interval t = t
c
between successive isochrones = 3 hr =
24
8
=
t
c
N
Clarks approach Eq. (17.13):
Q
2
= CI + C
2
Q
1
C =
t
k t + /2
=
3
12
3
2
+
= 0.2222, C
2
=
k t
k t

+
=

+
/
/
/
/
2
2
12 3 2
12 3 2
= 0.7778
Check: C + C
2
= 0.2222 + 0.7778 = 1 O.K.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 401
INSTANTANEOUS UNIT HYDROGRAPH (IUH) 401
From the sub areas A
r
, Eq. (17.11): I = 2.78
A
t
r
= 2.78
A
r
3
= 0.9267 A
r
Clarks: Q
2
= CI + C
2
Q
1
, C
2
Q
1
= 0.7778 Q
1
Q
2
= IUHO
CI = 0.2222 0.9267 A
r
= 0.203 A
r
Table 17.3 Computation of IUH by Clarks approach and hence 3-hr UG.
1 2 3 4 5 6
Time A
r
, (km
2
) CI C
2
Q
1
IUHO 3-hr
(hr) (from = 0.203 A
r
= 0.7778 Q
1
Q
2
(cumec) UGO
TAD) = (2) 0.203 = (5) 0.7778 = CI + C
2
Q
1
(cumec)
previous = (3) + (4) (by averaging)
0 0 0 0 0
3 32 6.4 + 0 6.4
0 6 4
2
+ .
= 3.2
6 67 13.5 + 5.1 18.6
6 4 18 6
2
. . +
= 12.5
9 90 18.0 + 14.9 33.0 25.3
12 116 23.3 26.4 49.7 41.3
15 135 27.0 39.7 66.7 58.2
18 237 47.5 53.0 100.5 83.6
21 586 117 80.0 197.0 148.8
24 687 137.5 157 294.5 245.7
27 A
r
= 1950 km
2
0 230 230 262.2
30 0 179 179 204.5
33 0 139.5 139.5 159.2
Plot Col. (5) vs. col (1) to get IUH, and Col (6) vs. col. (1) to get 3-hr UG. Note that the two peaks
are staggered by 3 hr; i.e., IUH is more skewed.
OUE8TON8
1 Define IUH and state its important properties illustrated in a neat sketch. What are the advan-
tages of IUH over a UG of finite duration?
2 Determine the values of n and k, and hence derive an IUH for the drainage basin in Example 5.2.
State its peak and time to peak.
3 For the IUH obtained in (2) above, derive a 6-hr UG and compare with that obtained in
Example 5.2.
4 Derive an IUH by Clarks approach and hence a 2-hr UG for a catchment of 140 km
2
, t
c
= 18 hr,
K = 12 hr. The catchment was divided into 9 zones by drawing 8 isochrones. The areas planimetered
between the successive 2-hr isochrones are 8 (near outlet) 12, 25, 35, 22, 16, 10, 8 and 4 (remote
end) in km
2
.
peak of
IUH

0
.7
8

0
.7
8
(peak
of UG)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD17-1.PM5 402
402 HYDROLOGY
5 (a) Explain the concept of Clarks IUH.
(b) The shape of a catchment can be approximated to a square with diagonal of 60 km. The main
channel is nearly along a diagonal; the isochrones may be assumed perpendicular to the
main channel. The travel speed along the main channel may be taken as 5 km/hr. Derive the
IUH for the basin with K = 5 hr
Hint: t
c
= 12 hr. Divide the diagonal into 6 parts to obtain successive 2-hr isochrones.
6 The IUH of a basin can be approximated to a triangle of base 36 hr and peak of 30 cumec at 9 hr
from the start. Derive a 3-hr UG for this basin.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Chapter 18
403
CLOUD SEEDING
18.1 CONDITIONS FOR CLOUD SEEDING
Between the vanishing forests and the reluctant clouds, the draught has advanced menac-
ingly. This is where cloud seeding will help win the battle.
Cloud seeding was discovered as accidentally as most scientific discoveries. In 1946,
when Dr. Vincent J. Schaefer working with GE in New York was trying to create artificial
clouds in a chilled chamber, he placed dry ice inside to cool the chamber. Water vapour inside
formed a cloud around the dry ice. That is pretty much how in a normal cloud ice crystals form
when cold water contacts particles of dust, salt or soot.
In clould seeding, silver iodide or other agents like common salt are introduced, which
mimic the ise crystal; the number of these nuclei available is increased and these can take in
more moisture in the cloud and form raindrops, which otherwise would not have formed. This
increased condensation and freezing releases a large amount of heat that makes clouds more
buoyant and extends them sidewards and upwards. As clouds grow taller, their updraft in-
creases, they draw in more moist air from the near surface and their size increases further.
Enlarged clouds then encroach over several smaller clouds nearby and grow further,
and hence the duration and quantity of rainfall will increase.
Rain clouds 69 km high and containing 0.5 mcm (million cubic meter) of water seeded
with silver iodide can be raised by 2 km and their water content increased to >1 mcm. Seeding
of multi-cell clouds leads to very high precipitation as compared to single cell clouds. Cloud
seeding has been carried out quite successfully in several countries including USA, Israel,
Russia, Canada, Australia and India. Clouds have been seeded at a height of around 2 km
above sea level.
However, it should be known that cloud seeding can only accelerate and increase the
amount of rainfall and not create rainfall, when the conditions are not favourable, as what hap-
pened when seeding was done in 1975 in Linganamakki area of Sagar (Shimoga Dist., Karnataka);
the seeded clouds had drifted away do to wind; also the clouds were floating below 1.2 km level.
Cloud seeding can not be done in the areas where there are no chouds as it can only
make the bad clouds to yield more.
The conditions favourable for cloud seeding are:
(i) the lower surface of the clouds should be within 1 km from the ground surface.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD18-1.PM5 404
404 HYDROLOGY
(ii) the relative humidity must be high, >75% and wind velocity < 1520 km/hr.
(iii) the temperature inside the cloud should be less than the freezing point of water.
Cloud seeding can be done either from above or from below, as illustrated in the following.
Seeding from above is resorted when a large area is concerned. This requires special
aircraft that can travel to heights where precipitation occurs, and can carry large loads of
seeding material. The four major requirements are:
(i) equipment of clould-condensation-nuclei measurement,
(ii) facility for photographing of cloud growth,
(iii) temperature measurement, and
(iv) 2-D Doppler Echo measurement of precipitation particles.
The weather radars are setup at land surface at air bases for locating the movements of
rain potential clouds and will cover nearly 400 km
2
. A Doppler weather radar with a range of
200400 km was setup at air bases of Bidar, Hubli and Jakkur (in Karnataka).
The operation of monitoring the rain efficient clouds are done through the computer-
aided system on board the cloud seeding aircraft with the support of the communication devices
from the base station. The turbo-prop aircraft titled Piper-PA 31 with special equipment and
extra fittings arrived from the US-based Weather Modifications Inc. (WMI) for enhancing the
rainfall by 25% in the drought-hit districts of Karnataka following the failure of rainfall for the
third consecutive year at a cost of Rs. 5.6 crore, in August 2003. The tender proposal was
prepared by experts from IITM and IMD.
The WMI, a cloud seeding company based in Fargo, north Dakota in the USA, has carried
out cloud seeding operations in fifteen countries and most of their operations were successful.
WMI had quoted Rs. 8 crore for the cloud seeding operations in Karnataka in August 2003.
WMIs competitor was Atmospheric INC. (AI), which is also a US-based company.
Experts of WMI started the 90-day Project Varuna from August 18, 2003. The WMI
had the radar and control room at Agni Aerosports in Jakkur Airfield at Bangalore. The radar
to scan for rain-bearing clouds in the range of 200 km and give informulation to the pilot and
crew of the aircraft, who in turn fly to the region and carry out the cloud seeding operations.
While the popular form of cloud seeding is through spraying from aircraft, approach
from below also has been used, as in Hyderabad in July 1993. Using ground generators
consisting of hot ovens and a blower, coal is heated to 1200 C and silver iodide sprinkled. The
rising fumes went straight into the sagging clouds. In minutes-there was a downpour for half
an hour resulting in increased waterlevel in Osman Sagar Lake (Hyderabad). The samples
showed traces of silver iodide proving the rains were due to the seeding.
18.2 CLOUD SEEDING TECHNIQUE
When nature is reluctant to produce ice in super-cooled clouds, it is possible to lend a hand by
providing the ice nuclei that nature is lacking. This is commonly called cloud seeding and it
could be done with a variety of ice-inducing agents like silver iodide or sodium chloride.
When silver iodide is used, small amounts are burned in flares or solution at the cloud
top or in the updrafts at the cloud base with the help of aircraft flying, the rapid development
of large number of small ice droplets soon follows.
When sodium chloride is sprayed on to the clouds with the help of aircraft, it precipi-
tates the cloud particles, which are usually of 100 microns, , (1000 = 1 mm), into larger
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD18-1.PM5 405
CLOUD SEEDING 405
particles upto 6-7 mm. When the particles increase in size, they can not hold together and
come down to the earth resulting in rain. This precipitation also happens naturally during
normal rains.
Fig. 18.1 A hygroscopic cartridge being burnt to demonstrate the process
of cloud seeding, which was inaugurated at the Jakkur airfield in Bangalore on Monday-Aug. 2003
Fig. 18.2 An aircraft fitted with flares containing nuclei used for cloud
seeding operation can be seen in this file photo
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\HYD18-1.PM5 406
406 HYDROLOGY
Cloud seeding however, artificially presses the cloud particles to precipitate and result
in rain. The chances of rains increase by about 30% due to cloud seeding.
Though sodium chloride is normally used in the tropical region which gets Warm rains
(where small cloud particles become bigger resulting in rain), silver iodide is used in cold
rains (which occur in high altitudes) in which water particles in cloud freeze and in turn
result in rain. Silver iodide enhances the chances of water particles freezing.
Both the chemicals were used for cloud seeding in Karnataka during August 2003.
18.3 CLOUD SEEDING OPERATION
To begin with, one has to identify the clouds, which can not yield rains due to shortage of (ice/
water) nuclei; after that, the exact number of nuclei to be added to such clouds to make them
yield rains, has to be found out.
Then, the technical team will calculate the quantity of silver iodide that has to be added
to the clouds to get the required increase in nuclei. This could be done through computer-aided
system on board the aircraft with the input as well as communication from the base-station.
The addition of nuclei would be facilitated by burning silver iodide flares. The crew may have
of six memberstwo pilots, two meteorologists and two technicians for carrying out the cloud
seeding operations. The aircraft should be capable of 6 hr endurance at operational altitudes,
having computer-aided control for scientific management of cloud sceding operations.
Cloud seeding is not so costly and the benefit-cost ratio may be around 60: 1. Several
scientists are still sceptical as to how effective the cloud seeding is ! Is the rain in most cases
due to the seeding or was it anyway poised to rain, they ask. But one thing they all agree, is
that there have been no negative effects from cloud seeding so far with regard to polluting the
environment or the chemicals used. The criticisms are about the possibility of creating bad
weather or floods; and of course increasing rainfall in one region is at the expense of rainfall in
a neighbouring local region.
18.4 RECENT CASE HISTORY
Russian air forces special squad air craft was pressed into service on Monday (9th May 2005)
to clear cloud-cover over MOSCOW, so that no rain clouds dampen the Victory Day celebrations
(marking the 60th anniversary of the Allied Victory over Nazi Germany in World War II)
attended by leaders of 53 nations.
At 5.30 A.M. (local time), 12 Antonov An-12 and Ilyushin IL-18 aircraft took position in
the sky over Moscow, divided in 10 zones, as a cyclone from the west advanced towards the
capital.
Flying at 3-8 km altitude, the planes sprinkled various chemicals including silver iodide,
liquid nitrogen, dry ice (frozen carbon dioxide) and even ordinary cement to seed the clouds at
a distance of 50-150 km away. By 10 A.M. sharp at the start of the military parade, rain had
stopped in Red Square and the sky was clear for the impressive flypast by Sukhoi and MIG
fighters. For the first time in Moscow, computer-designed fireworks were used on Monday
night, and the efforts were to keep the sky clear till date in the night.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
In most parts of the Western Countries, snowmelt produces the major portion of the
annual runoff. The high altitudes in the Himalayan range are snow covered and there is an
appreciable snowmelt runoff in the rivers, which originate from the Himalayan range.
Snow cover is usually more variable than precipitation within a given area. The
hydrologist is concerned with the structure attained by the snow just prior to melting, the area
and depth of snow pack, the rates of snowmelt, and the resulting runoff in the stream due to
snowmelt and concurrent rainfall. The measurements of snow depths can be done by snow
survey, snow gauging, and remote sensing by satellite.
Physics of Snowmelt
The sources of energy to melt snow may be broadly classified as:
(i) radient heat from the sun,
(ii) latent heat of vapourisation released by condensation of water vapour, and
(iii) heat by conduction from the environment of snow, such as from the ground, rainfall,
and air.
The snow pack may also loose heat to its environment by radiation, sublimation and by
conductivity. The melting of snow, due to the interactions of the various phenomena of heat
exchange, makes it one of the most complex in the field of hydrology.
The most common source is solar radiation. The amount of radiation effective in the
melting of snow is dependent on its reflectivity or albedo. About 90 per cent of the radiation
incident on clean, fresh snow is reflected (without causing melt), while lesser amounts are
reflected from old and dirty snow.
Conduction from still air causes very little melt (due to its low heat conductivity). Tur-
bulence resulting from wind, brings large quantities of warm air into contact with the snow,
and heat exchange takes place. If the dew point of the air is less than the snow-surface tem-
perature, the vapour pressure of snow (e
s
) is greater than that of the air (e
a
) resulting in evapo-
ration from the snow surface; on the other hand, if the dew point is above freezing, condensa-
tion on the snow occurs, with consequent release of latent heat.
Appendix A
SNOWMELT RUNOFF
407
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 408
408 HYDROLOGY
Snow melt (M
s
) due to convection is proportional to the difference in temperature of the
air (T
a
) and the snow (T
s
), while due to conduction the snowmelt is proportional to the vapour
pressure gradient (e
a
e
s
) ; both the two processes are influenced by the wind speed (V
w
) and
are given by
M
s
(air-convection) = k
c
(T
a
T
s
)V
w
M
s
(vapour-condensation) = k
v
(e
a
e
s
)V
w
where T
s
= 0 C
e
s
= saturation vapour pressure in mb at 0 C (= 6.11)
k
c
, k
y
= exchange coefficients
V
w
= average wind speed
If the vapour pressure of the air is higher than that of ice at 0 C, the moisture (vapour)
brought by turbulence in the air, condences on the snow surface. Since the condensation of
water at 0 C is 596 cal/g and the heat of fusion of ice is 80 cal/g, the condensation of 10 mm of
water vapour on the snow surface causes
596
80
10 = 7.5 10 = 75 mm of melt water from the
snow. Hence, the wind speed (which causes turbulence) is an important factor in computing
snowmelt.
Rainfall, at temperature above freezing, causes snowmelt and is given by the simple
calorimetric equation
M
s
=
PT
w
80
where M
s
= snowmelt (mm)
P = rainfall (mm)
T
w
= wet-bulb temperature (C)
If T
w
= 20 C, 20 mm of rain will cause
20 20
80

= 5 mm of melt water from the snow.


Thus rainfall is less effective in causing snow melt, while the strong winds, warm air and high
humidity which accompany rainfall cause appreciable melt during rainstorms.
Forest cover, land slope (topography), influence wind, temperature and humidity of the
air, and appreciably affect the amount of radiation incident on snow; hence, the importance of
environment on the snowmelt.
If the basin is covered with a fairly uniform depth of snow, the snowmelt can be esti-
mated by the use of the degree-day factors. The degree-day factor is the depth of water melted
from the snow in mm per degree-day, i.e., mean daily temperature of 1 C above freezing
temperature (0 C), and can be determined by dividing the volume of streamflow as a result of
snowmelt during a certain period by the total degree-days for the period. The factor usually
ranges form 2-7 mm/degree-day. Since solar radiation, humidity and wind affect snowmelt,
some variation in the degree-day factor from day to day may be expected and seems to increase
as the melting period progresses*, Fig. A-1. There is a time lag between the snowmelt and the
streamflow observed, so that the latter is not a measure of the former.
*Linsley R. K., A Simple Procedure for Day-to-Day Forecasts of Runoff from Snow Melt, Trans.
Am. Geophys. Union, Vol. 24, pp. 62-67, 1943.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 409
APPENDICES 409
Degree-day factor
increases as the
melting period progresses
N D J F M A M Jn Jl
Melting period (months)
10
8
6
4
2
0
m
m
/

C
d
a
y
Fig. A-1 Degree-day factor variation (after Linsley, 1943)
Since snowmelt occurs at higher altitudes and the temperature varies with the altitude,
the records of a single station do not indicate the actual degree-days unless the station is
located at mid-elevation of the range. The snow pack may not be of uniform depth, being
shallower at lower elevations. The line of zero snow depth is known as the snow-line. One of
the methods of computing snowmelt in mountain ranges is to establish observation stations
for the location of snowline and the areas covered by snow. The snowmelt can be computed by
estimating the average elevation of the sonwline and assuming the variation of temperature
with altitude.
The computations of snowmelt can be made with a more reasonable success by compu-
ter simulation and the simulated snowmelt is used as input in the runoff simulation model
(Fig. 16.3), to determine the stream flow.
Snow Surveying
In snow surveying, a snow traverse is conducted and sampling points are chosen along a rep-
resentative snow course. At each sampling point, a tube is driven down through the snow and
a snow sample is collected. From this sample, the depth of snow, the water equivalent (the
depth of water whose weight is equal to that of the snow pack) and the density of snow can be
determined. The density is the percentage of snow volume, which its water equivalent would
occupy. Freshly fallen snow has a density of about 10 per cent. As time elapses, it becomes
more dense and compact due to coarsening of the crystal structure and settling. The quality of
snow is the decimal fraction of its total weight, which is in the form of ice and can be deter-
mined by the calorimetric principle. The quality of snow usually varies from 0.95 to 0.70,
depending on the rate of melting, the structure of the snow pack and the infiltration capacity
of the uderlying ground surface, which affects drainage.
A pressure pillow gauge is sometimes used to determine the water equivalent of snow.
The pillow is made of thin butyl rubber of diameter ranging from 1.5 to 3.5 m ; larger the size,
greater is the accuracy. The pillow is filled with a mixture of water and antifreeze. The inter-
nal pressure increases as the snow accumulates on the pillow. The weight of snow is deter-
mined by measuring the pressure with a manometer or pressure transducer.
Example A-1 During a snow survey, the data of a snow sample collected are given below:
Depth of snow sample 2 m
Weight of tube and sample 25 N
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 410
410 HYDROLOGY
Weight of sample tube 20 N
Diameter of tube 40 mm
Determine
(i) the density of snow
(ii) the water equivalent of snow
(iii) the quality of snow, if the final temperature is 5 C when 4 lit. of water at 15 C is
added.
Solution (i) Density of snow is the same as its specific gravity
Sp. gr. of snow, G
s
=


s
w
s s
w
W V
=
/
=
( ) / ( . )
.
25 20 0 020 2
1000 9 81
2

= 0.203
(ii) Density of snow, G
s
=
Depth of melt water
Depth of snow
( )
( )
d
d
w
s
Water equivalent of snow, d
w
= G
s
d
s
= 0.203 2 = 0.406 m
(iii) If the actual weight of ice content in the sample is W
c
gm, then
Heat gained by snow = Heat lost by water
Heat required to melt + to rise temperature to 5 C
W
c
80 +
5
9 81 .
1000 5 = 4000(15 5)
Solving, W
c
= 468.2 gm = 0.4682 9.81 = 4.6 N
Quality of snow =
4 6
5
.
= 0.92
Example A-2 If the density of a snow pack 1.2 m depth is 20%, determine its weight density,
mass density, sp. gr. and water equivalent.
Solution The density is the percentage of snow volume, which its water equivalent would
occupy.
Snow density =
Depth of melt water
Depth of snow
( )
( )
d
d
w
s
0.20 =
d
d
w
s
Water equivalent of snow, d
w
= 0.20 1.2 = 0.24 m
Weight density,
s
=
W
V
W
V
V
V
d
d
s
s
w
s
w w
s
w
s
= = =


w
= 0.20 (1000 9.81) = 1962 N/m
3
Mass density,
s
=
M
V
W g
V g
s
s
s
s
s
= = =
/
.
1962
9 81
= 200 kg/m
3
Sp. gr., G
s
=

s
w
=

1962
1000 9 81 .
= 0.2
Note, that the specific gravity is the same as the snow density.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 411
APPENDICES 411
Example A-3 The average snow line is at 1400 m elevation and a temperature index station
located at 1800 m elevation indicated a mean daily temperature of 8 C on a certain day.
Assuming a temperature decrease of 1 C per 200 m increase in elevation and a degree-day
factor of 3 mm/degree-day, compute the snowmelt runoff for the day. An area elevation curve for
the sno pack is shown in Fig. A-2.
4000
3600
3200
2800
2400
2000
1600
1200
800
400
0
0 100 200 300 400 500 600 700 800 1000 1 2
Area above indicated elevn. (km )
2
E
l
e
v
a
t
i
o
n
a
b
o
v
e
m
s
l
(
m
)
3400 m Freezing elevn. (0 C)
Snow pack
T
e
m
p
.
f
a
l
l
1

C
/
2
0
0
m
1800 m (8 C)
Snow line
1400 m (10 C)
Elevn. of
Temp. index stn.
Ave. elevn.
of snow line
680 km
2
Melting zone
(Ave. temp. = 5 C)
3 mm/C day
=
0 + 10
2
Fig. A-2 Area-elevation curve for snow pack
Solution Freezing occurs at higher altitudes when the temperature falls to 0 C.
Freezing elevation = 1800 + (8 0) 200 = 3400 m. The area between the snow line
elevation of 1400 m and the freezing elevation of 3400 m is read out from the area-elevation
curve, Fig. A-2 as 680 km
2
. The average temperature over this area is
1
2

0 8
1800 1400
200
+ +
R
S
T
U
V
W
L
N
M
M
O
Q
P
P
Cat C
freezing elevn. at snow line elevn.
=
1
2
(0 + 10) = 5 C.
Snowmelt runoff for the day
= 0.003 5 C (680 10
6
) = 10.2 10
6
m
3
= 10.2 km
2
-m or 1020 ha-m
Note: 1 km
2
= 100 ha.
Assignment Problems
1 A snow sample of volume 0.015 m
3
weighs 22N and gives a final temperature of 7 C when mixed
with 7 lit. of water at 32 C. If the depth of snow pack is 0.6 m, calculate the specific gravity,
water equivalent, and the quality of snow.
Is the specific gravity same as the snow density ? Prove.
0.15, 90 mm, 0.89, G
d
d
s
w
s
=
F
H
G
I
K
J
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 412
412 HYDROLOGY
2 For a certain period in a mountain range, the degree-day factor is 4 mm/C-day. How much the
depth of snow pack decreases on a warm spring day with maximum and minimum temperature
recorded as 25 C and 7 C, respectively. Assume a sp. gr. of 0.16 for the snow. If the area covered
by snow is 450 km
2
, estimate the snowmelt runoff on the day.
Whether this snowmelt and the stream flow observed on the day are concurrent? Explain.
(0.4 m, 28.8 Mm
3
)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
In open-channel hydraulics, overland flow is considered as sheet flow, a spatially varied
unsteady flow. Many investigators have made analysis of overland flow and Izzards method
has been found to be more practical.
Laminar Overland Flow
For small plots without defined channels, with short, mild, uniform slopes, such as parking
lots, airports, runoff occurs as laminar overland flow for which the critical Reynolds number is
given by
R
e
=
Vd q

=
< 1000 ...(1)
where d and q are the uniform depth and discharge per meter with of overland flow, respec-
tively. Izzard has suggested that for rectangular plots, laminar flow occurs if
i
net
l < 4000 ...(2)
where i
net
is the net rainfall in mm/hr, and l, b are the length and breadth of the plot in metres.
Since q = i
net
l, Eqs. (1) and (2) in consistent units agree.
Forces under steady, uniform laminar overland flow are shown in Fig. B-1; forces on the
element of water P
1
= P
2
. For steady flow and for b = 1
(x . 1) = W sin
Putting sin = tan = S
for small values of , S is the land slope, is the shear stress at a depth y above the land
surface. Substituting for W,
x = x (d y)
w
S
or =
w
S(d y)
Putting y = 0, the bed shear
0
=
w
dS ...(3)
From the Newtons law of viscosity,
=
dv
dy
Appendix B
OVERLAND FLOW
413
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 414
414 HYDROLOGY
P
Water sheet
t g
0 w
= d S
a
t
0
S
a
Land slope
W
W sin a
sin a = tan = S a
(a) Forces acting on water sheet
t
S
a
Land slope, S
DW = x 1(d y) D g
w
P
d
P
d
Element of water
a
v
v
s
P
D
x
x1
DW sin a
(b) Forces acting on the water element
y
V
Fig. B-1 Overland flow analysis

dv
dy
=
w
S(d y)
dv =

w
S
(d y)dy
Integrating both sides,

z
dv =

w
S
d y dy
z
( )
v =

w
S
dy
y

F
H
G
I
K
J
2
2
+ C
At the land surface, y = 0, v = 0, C = 0.
The velocity at any depth y above the land surface is given by the parabolic equation
v =

w
S
dy
y

F
H
G
I
K
J
2
2
...(4)
Mean velocity V is given by
V =
1
0 d
vdy
d
z
=
1
2 0
2
d
S
dy
y
d
w
z

F
H
G
I
K
J

dy, from Eq. (4)


V =

w
S
3
d
2
...(5)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 415
APPENDICES 415
The discharge, q = Vd,
q =

w
S
3
d
3
...(6)
Note that q ~ d
3
S, so that if q is constant but slope S varies, d and V at another section
can be estimated.
The velocity at the water surface v
s
is obtained by putting y = d in Eq. (4)
v
s
=

w
S
2
d
2
...(7)
which is the maximum velocity.
t
0
t
S
h
e
a
r-
s
tre
s
s
d
is
trib
u
tio
n v
s
v
V
x
P
a
ra
b
o
lic
v
e
l.
d
is
trib
n
.
y
d
-y
d
S
h
e
e
t
o
f
w
a
te
r
S
0
.5
8
d
Fig. B-2 Laminar overland flow
From Fig. B-2,
v = v
s
x
v
v
s
= 1
x
v
s
x = v
s
v
x =

w
S
2
[d
2
(2dy y
2
)] from Eqs. (4) and (7)

x
v
s
=
d dy y
d
d y
d
2 2
2
2
2
2 +
=
( )

v
v
s
= 1
d y
d
F
H
G
I
K
J
2
...(8)
when v = V,
V
v
s
= 1
d y
d
F
H
G
I
K
J
2
Since the velocity distribution is parabolic, the mean velocity V is two-thirds of the
maximum velocity v
s
, i.e., V =
2
3
v
s
, or
V
v
s
=
2
3

2
3
= 1
d y
d
F
H
G
I
K
J
2
or
d y
d
F
H
G
I
K
J
2
=
1
3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 416
416 HYDROLOGY
d y = 0.58 d ...(9)
which is in close agreement with the mean velocity position for turbulent stream flow ( 0.6 d
or mean of the velocities at 0.2 d and 0.8 d).
Turbulent Overland Flow
The equation for the turbulent over land flow can be obtained by using the Mannings equation
q = (d . 1)V = (d . 1)
1
n
R
2/3
S
1/2
Since the hydraulic mean radius
R d, for broad surfaces
q =
1
n
d
5/3
S
1/2
...(10)
From Eqs. (6) and (10), for both laminar and turbulent overland flows, from theory and
experiments, the equation of flow is of the general form
q
e
= Kd
e
m
S
n
...(11)
Where K, m and n are constants varying with the Reynolds number R
e
, raindrop impact,
and land roughness. For turbulent flow m = 1.67, n = 0.5 and for laminar flow, m = 3, n = 1. C.F.
Izzard (1946) developed the expression for the laminar overland flow as
q
e
= Kd
e
3
S ...(12)
where K =
1
2 8 10
5
3
. +
L
N
M
O
Q
P

i C
q
e
= equilibrium flow in m
3
/S per m width of strip at the lower edge of the rectangular
area of uniform slope S.
d
e
= volume of detention storage, expressed as the average depth over the full length of
the strip of unit width, whereas in Eqs. (1) to (10), d is the depth at a particular section where
the discharge is q.
i = the actual rainfall intensity in mm/hr, not the net rate, since the term 2.8 10
5
i
is intended to represent the retarding effect of rain-drop impact.
C = a roughness factor depending upon the type of land surface. Experimental values of
C reported by Izzard are given below:
Type of surface Value of C
Concrete pavement 0.012
Tar and gravel pavement 0.017
Tar and sand pavement 0.0075
Smooth asphalt pavement 0.007
Crushed-slate roofing paper 0.0082
Dense bluegrass turf 0.060
Closely clipped sold 0.046
Determination of Overland Flow Hydrograph from Rainfall Data
Eqs. (11) and (12) are for equilibrium flow conditions and will not give correct values for dis-
charge during periods of unsteady flow, which occur during actual storms. Due to time lag
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 417
APPENDICES 417
between rainfall and discharge, they give too high values of discharge during the rising stage
and too low values during recession time. A simple method is to divide the net-rain hydrograph
to a few broad steps, as shown in Fig. B-3 and then draw the discharge hydrograph for each
step. The rising hydrograph for the first step is obtained from the empirically derived
dimensionless S-hydrograph (Fig. B-4). The equilibrium time t
e
is taken as the time when the
discharge q reaches 97 per cent of the equilibrium discharge q
e
and this provides a good keypoint.
1
2
3
Net-rain
Time t (min)
I
n
t
e
n
s
i
t
y
i
(
m
m
/
h
r
)
a. Hyetograph divided
into steps 1, 2, & 3
b. Runoff hydrograph
for each step
R
u
n
o
f
f
(
m
m
/
h
r
)
q
e
1
q
e
2
q
e
3
Overland flow
hydrograph
Time t (min)
Fig. B-3 Overland flow hydrograph derived from rainfall data
b
a
a. rising limb b. recession curve
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0 0.1 .2 .3 .4 .5 .6 .7 .8 .9 1.0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5
(t/t )
e
b-values
(
q
/
q
e
)
Fig. B-4 Izzards dimensionless graph (after Izzard, 1946)
Since the S-hydrograph divides the graphical plot approximately into two equal parts,
the average discharge during the time t
e
can be taken as q
e
/2, which should be equal to the
volume divided by the time, i.e.,
q d l
t
e e
e
2
=
...(13)
from which the equilibrium time t
e
can be computed.
Izzard provides techniques for computing the transition hydrographs for higher steps
(when water is deeper and faster), shorter steps (when q does not reach q
e
) and the recession
periods, based on Eq. (12).
The dimensionless recession curve Fig. B-4 defines the shape of the receding limb. At
any time t
a
after the end of rain, the factor is given by
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 418
418 HYDROLOGY
=
q t
d l
e a
e0
...(14)
where in consistent units and d
eo
= d
e
taking i = 0.
Example B-1 Equilibrium overland flow occurs over a rectangular area 100 m long due to a
uniform net rainfall of 50 mm/hr. At what distance from the upper edge of the area the flow
changes from laminar to turbulent if the temperature is 20 C and the critical Reynolds number
is 800.
Solution R
e
=
vd q

=

water
at 20 C = 0.01 St = 0.01 10
4
m
2
/S or 1 10
6
m
2
/S
800 =
q
1 10
6

q = 8 10
4
cumec/m
q = i
net
l, 8 10
4
=
50
1000 60 60
l
l = 57.6 m, beyond which the flow becomes turbulent.
Note: For laminar flow, i
net
l < 4000 (Izzard)
l <
4000
50
, i.e., l < 80 m (this assumes critical R
e
= 1000)
Example B-2 A concrete-paved area is 200 m long by 100 m wide and has surface slope of
0.005. The design storm is given by
i =
250
0.4
(imm/hr, t-min)
Construct the outflow hydrograph for a 1-hr storm using Izzards method.
Solution Equilibrium discharge, q
e
= i
net
(l 1); for t = 60 min, i =
250
60
0.4
= 48.5 mm/hr
Assuming i = i
net
for the concrete pavement (initially wet),
q
e
=
48 5
1000 60 60
.

(200 1) = 0.0027 cumec/m
From Eq. (11), q
e
= Kd
e
3
S
Depth of flow d
e
=
q
KS
e
L
N
M
O
Q
P
1/ 3
K
1/3
=
1
2 8 10
5
( . ) +

i C
=
1
2 8 10 48 5 0 012
5
( . )( . ) . +

=
1
0 01336 .
3 d
e
= 0.01336
0 0027
0 005
1/ 3
.
.
F
H
G
I
K
J = 0.0131 m, or 13.1 mm
From Eq. (12), the equilibrium time
t
e
=
2 2 0 0131 200
0 0027
d l
q
e
e
=
.
.
= 1940 sec = 32 min 20 sec
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 419
APPENDICES 419
D
a
t
a

t
o

p
l
o
t

t
h
e

r
i
s
i
n
g

t
i
m
b
D
a
t
a

t
o

p
l
o
t

t
h
e

r
e
c
e
s
s
i
o
n

c
u
r
v
e
q
/
q
e
Q


q
e
b

(


0
.
2
7
)

=

(
m
3
/
s
)
t
/
t
e
t


t
e

(


3
2
.
3
3
)

=

(

m
i
n
)
t
a

(
m
i
n
)


=

0

0
6
9

t
a
q
/
q
e

(
f
r
o
m

g
r
a
p
h
)
(


0
.
2
7
)

=

Q

(
m
3
/
S
)
0
0
0
0
5
0
.
3
4
5
0
.
4
5
0
.
1
2
1
0
.
2
0
.
0
5
4
0
.
3
1
1
0
.
0
7
.
5
0
.
5
1
7
0
.
3
0
0
.
0
8
1
1
0
0
.
6
9
0
0
.
2
7
0
.
0
7
3
0
.
4
0
.
1
0
8
0
.
4
2
1
3
.
6
1
5
1
.
0
3
5
0
.
1
8
0
.
0
4
9
2
0
1
.
3
8
0
.
1
3
0
.
0
3
5
0
.
6
0
.
1
6
2
0
.
5
2
1
6
.
8
2
5
1
.
7
2
0
.
1
1
0
.
0
3
0
3
0
2
.
0
7
0
.
0
9
0
.
0
2
4
3
0
.
8
0
.
2
1
6
0
.
6
7
2
1
.
7
4
0
2
.
7
6
0
.
0
6
0
.
0
1
6
2
5
0
3
.
4
5
0
.
0
4
0
.
0
1
0
8
0
.
9
7
0
.
2
6
1
1
.
0
0
3
2
.
3
6
0
4
.
1
4
0
.
0
3
5
0
.
0
0
9
4
6
5
4
.
5
0
0
.
0
3
0
.
0
0
8
1
T
a
b
l
e

B
-
1

T
o

p
l
o
t

t
h
e

o
u
t
f
l
o
w

h
y
d
r
o
g
r
a
p
h

u
s
i
n
g

I
z
z
a
r
d

s

d
i
m
e
n
s
i
o
n
l
e
s
s

g
r
a
p
h
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 420
420 HYDROLOGY
0.30
0.25
0.20
0.15
0.10
0.05
0
0 5 10 15 20 25 30 35 40 45 50 55 60 5 10 15 20 30 40 50 60
After rain starts, t (min) After end of rain, t (min)
a
D
i
s
c
h
a
r
g
e
Q
(
m
/
s
)
3
Rainfall rate
Volume of
surface
detention
Q = qb
End of rain-fall
Recession
curve
t
R
Fig. B-5 Overland flow hydrograph (Example B-2)
Recession factor,
=
q t
d l
e a
e0
, d
e0
=
q
KS
e
F
H
G
I
K
J
1/ 3
K
1/3
=
1
0012 .
(with i = 0)
d
e0
= 0.012
0 0027
0 005
1/ 3
.
.
F
H
G
I
K
J = 0.01175
=
0 0027 60
0 01175 200
. ( )
.
t
a

where t
a
= time after the end of rain in min.
= 0.69 t
a
From the data in Table B-1, the overland flow hydrograph is constructed as shown in
Fig. B-5.
Example B-3 If the depth of surface detention on a smooth surface is 4 mm and the slope is
0.01, determine the wind velocity in the upslope direction required to counterbalance the com-
ponent of gravity force down slope, if the rainfall rate is 60 mm/hr.
Solution (a) Let the wind velocity be V
w
towards upslope (Fig. B-6).
Element of water sheet
V
w
a
S
a
A
re
a
1

1
D g W = (1 1 d )
e w
d
e
D a W sin = DW.S
Fig. B-6 Effect of wind on overland flow (Example B-3)
Q = iA =
0 060
60 60
.

(1 1) =
0 001
60
.
m
3
/S
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP.PM5 421
APPENDICES 421
Force exerted by wind
F = Q(V) = 1000
0 001
60
.
V
w
=
V
w
60
N
Force downslope due to gravity
W
s
= W sin = (1 1 d
e
)
w
. S
= 0.004 (1000 9.81) 0.01 = 0.3924 N
Equating F = W
s
, velocity of wind
V
w
= 0.3924 60 = 23.544 m/s
or
23544 60 60
1000
.
= 85 km/hr
In the case of moderate slopes, such as airport runway surfaces, wind may play an
important part in determining the rate of overland flow.
The raindrop velocity in the direction of wind is equal to the wind speed and the corre-
sponding driving force F = Q(V) and Q = iA. Thus, it is even possible that a considerable
portion of the overland flow might be driven up the landslope and over a divide into an adja-
cent drainage area.
Assignment Problems
1 Overland flow of 6 10
4
m
3
/s per metre width occurs over a smooth surface at a temperature of
20 C. Is the flow laminar or turbulent? If the uniform depth is 3 mm, determine the mean
velocity, the surface velocity, and the velocity at mid depth.
(Laminar: R
e
= 600, 0.2, 0.3, 0.225 m/s)
2 Water is allowed at a steady rate at the upper edge of a sloping surface of constant width and 100
m length. The slope is 0.01 for the first 50 m and 0.05 for the remaining 50 m. If a mean slope for
the entire length is assumed, determine the percentage error in the estimation of mean velocity
for laminar flow.
3 For steady laminar flow along an undulating slope of constant width, if the depth and velocity at
one section are 0.3 m/s and 3 mm, respectively, determine the velocity and depth at another
section of twice the slope. Determine the Reynolds number for both the sections assuming a
temperature of 20 C. (Hint: q ~ d
3
S, q = dV) (0.378 m/s, 2.38 mm, 900)
4 An area of 4 ha has an average length of overland flow of 60 m on concrete pavement with an
average slope of 0.003. The design storm is given by i =
250
0.5
t
where i is in mm/hr and t is in
minutes. For a 1-hr storm, find the time of concentration of overland flow. Assuming a flow time
of 10 min in the gutter across the slope at lower edge, what is the peak rate of runoff expected ?
5 Determine the equilibrium time for 50 mm/hr net rainfall on a wet surface of slope 0.01 and
length 60 m, if the surface is (a) concrete pavement, and (b) dense bluegrass turf. (14,72 min)
6 Comment on the methods of determining peak rate of run-off from (a) small areas, (b)
large areas, and (c) areas of all sizes.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
The hydrological investigations to be made for the design of a multipurpose reservoir,
say for storage, flood control and power generation are given below :
Not only the storage capacity (size) of the reservoir, also the height of dam, crest eleva-
tion of the spillway and its length, the sill level of sluices, have to be determined for which
(i) an estimate for the runoff (yield) at the proposed dam site is required. If the stremflow
records at or near the dam site are not available for a number of years, the runoff
(yield) have to be obtained from the rainfall data.
(ii) the hydrograph of MPF (say by the application of PMS over a design unit hydrograph,
see Example 8.4) for spillway design and the flood moderating (absorbing) capacity
of the reservoir have to be obtained. The peak rate, the volume of flood flow, the
time of its occurrence and its duration, all influence the design.
Use of Hydrographs
(i) Determination of storage capacity A flow hydrograph for the river at the dam site for
a large number of years (<|2530 years) has to be obtained (Fig. C-1 (a)) from which a mass
curve of inflow can be drawn, (Fig. C-1 (b)) The mass curve of demand is computed from the
hydrograph of demand in the same way as mass curve of inflow is computed from the inflow
hydrograph, i.e., as cumulative outflow required versus time (months). The demand rate is
seldom uniform (as indicated by a straight line in Fig. C-1 (b), and usually varies according to
seasons (Fig. C-2).
From an inspection of mass curve in Fig. C-1 (b), cd appears to be the driest period on
record and pq is the volume of storage required to tide over this period. If there are two three
dry periods, the maximum departure, among pq, is the storage capacity required (to meet the
uniform straight line demand). In Fig. C-2, the variable mass curve of demand is superimposed
on the mass curve of inflow from the beginning of a severe dry cycle,till the two curves meet
again. The ordinate of maximum departure (mn) between the two curves is the required storage
capacity.
In a reservoir designed primarily for flood control, the capacity of the reservoir does not
depend on the pattern of demand to be met during a cycle of dry years but on the maximum
flood hydrograph of the river at the dam site and the safe channel capacity down stream.
Appendix C
RESERVOIR DESIGN STUDIES
422
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 423
APPENDICES 423
J F M A M J J A S O N D
1975 1976
1977 1978 1979 1980 1981 1982
(Year and months)
J F M A M J J A S O N D
1975 1976
1977 1978 1979 1980 1981 1982
(Year and months)
S
lo
p
e
=
d
e
m
a
n
d
ra
te
(Q
) Q
R
P
Time
S
t
o
r
a
g
e
U
n
ifo
rm
d
e
m
a
n
d
lin
e
OB || PQ || CD || EF
S > S
2 1
\ S = Reqd. reservoir
capacity
2
S
2
Storage capacity
of reservoir
E
F
(b) Mass curve of inflow
C
D
p
S
1
22
20
18
16
14
12
10
8
6
4
2
0
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
(
M
m
)
3
S
t
r
e
a
m
f
l
o
w
(
Q
c
u
m
e
c
)
1400
1200
1000
800
600
400
200
0
(a) Inflow hydrograph
A
B
q
Fig. C-1 Inflow hydrograph and mass curve
J F M A M J J A S O N D
1977 1978 1979 1980 1981
(Year and months)
18
16
14
12
10
8
6
4
2
0
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
&
d
e
m
a
n
d
(
M
m
)
3
Storage capacity
reqd. to meet
the demand
Mass curve of
demand
Mass curve
of inflow
O-beginning of driest period (or cycle)
m
n
Fig. C-2 Variable demand mass curve
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 424
424 HYDROLOGY
(ii) Determination of spillway crest level The principle measures of reservoir economy
are
(a) the cost of attaining the given objective/s.
(b) the return on the investment, i.e., on the ratio of benefits to cost (B/Cratios).
For the objective of flood control, the peak rate of reservoir release (peak of outflow
hydrograph) should usually be equal to the maximum safe channel capacity downstream mi-
nus a small allowance for local inflow downstream and margin of safety. For the maximum
rate of outflow thus established, floods of various magnitudes are routed through the reservoir
to determine the storage space required for effective regulation. This is done by trial and
involves the capacity curve of the reservoir and discharge curve of the outlets and spillway,
i.e., reservoir elevation VS storage capacity and discharge. The costs of providing the various
amounts of storage space (by increasing the height of spillway) are compared with the average
annual flood-control benefits to be expected (see Table 8.9) in order to determine B/C-ratios.
In other words, the inflow hydrograph (of MPF) into the reservoir and the safe peak rate of
outflow hydrograph from the reservoir being known (Fig. C-3), the storage space (surcharge
storage) required to moderate the former to the safe peak of the latter has to be determined, by
trial, for which the B/C ratio is maximum. In Fig. C-3, the peak outflow occurs at the point
where the two hydrographs cross, and the storage, and therefore, the hydraulic head, is maxi-
mum at this point.
Peak outflow, Q
(max. storage)
p
From
storage
Outflow hydrograph
(by routing IH)
For spillway
Q = C L H
p
3/2
Inflow hydrograph (IH)
of MPF for spillway design
To
storage
Equal
areas
I > O
Time t (hr)
Time when
storage is max. O > I
D
i
s
c
h
a
r
g
e
Q
(
c
u
m
e
c
)
Q
p
Fig. C-3 Spillway design flood
Allocation of reservoir space For the multipurpose reservoir operation, a space (storage
volume) is allocated for each objective. The storage data can be determined from a topographic
map of the reservoir site. Cross-sections of the reservoir site are sometimes surveyed and the
capacities computed from these vertical cross-sections (area-elevation data) by the use
trapezoidal or prismoidal formula. The elevation-area and elevation-capacity curves are shown
in Fig. C-4.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 425
APPENDICES 425
6 1500 4 3 2 1 1000 9 8 7 6 500 4 3 2 1 0
560
550
540
530
520
510
500
490
480
470
460
450
0 50 100 150 200 250 300 350 400
Capacity (Storage volume) (M.m )
3
E
l
e
v
n
.
a
b
o
v
e
m
s
l
(
m
)
Water spread area (ha)
550.00 TOB (TOD)
546.50 HFL (MWL)
542.50 SCL
FRL 543.5
E
levn.-capacity
curve
E
levn. area
curve
500.00 LSL (DSL)
471.00 RBL
Fig. C-4 Elevation-area-capacity curves for reservoir (Example C-2)
The various control levels in the operation of a multi-purpose reservoir are shown in
Fig. C-5. Full reservoir level (FRL) is at the level of the spillway crest or top of the spillway
gate. Towards the end of the flood season, the spillway gates are kept closed to store water
upto the top of the gate. The spill of the gate is well below the FRL in order to reduce the total
length of the spillway (since the head over the crest becomes more) for the passage of the
spillway design flood. The low reservoir level (LWL) is at the elevation of the lowest sluice
outlet and the water stored below LWL is the dead storage where the silt carried by the stream
accumulates and is usually kept at a about 10% of the gross reservoir storage (GS). In the case
of hydroelectric projects, the LWL to be maintained is from the point of minimum head re-
quired for the operating efficiency of the turbines and to supply firm power (i.e., the power
available all the year round ; power available during a part of the year is called secondary
power and has to be sold at a much lower rate or firmed by thermal installation). The storage
volume between the FRL and LWL is called the useful storage, which can further be divided
into conservation storage and flood control storage, according to the plan of operation of the
reservoir. With an adequate flow forecasting system, all or part of the reservoir storage below
FRL (say, between FRL and an intermediate reservoir level IRL) can also be made available
for flood control and multi-purpose regulation.
During normal flows, the reservoir level will be maintained in the vicinity of FRL and
the water will pass through the power conduits. Whenever a flood is forcest, the FRL is
drawndown to the extent that the flood runoff will bring the reservoir back to FRL. During low
flows, when FRL is reached, the release for power and downstream water requirements will be
reduced to minimum.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 426
426 HYDROLOGY
H Power conduit
Sluiceway Power
house
H = min. head
for firm power
Spillway
gates
550.00
TOD
Spillway
crest
546.50 MWL
543.50 FRL
542.50 SCL
Surcharge storage
Conservation storage
500.00 LSL/LWL
Seasonal
variation
of resv. level
Valley
storage
R
BL
471.00
River bed
Height
of dam = 79m
Low water
season
MAMF J DNOSA
Months Flood months
season
JDNOSAJJMA
T
T Turbine
TWL Tail water level
TWL
Fig. C-5 Multipurpose reservoir operation (Example C-2)
During high floods, the reservoir level will rise above FRL or well above the spillway
crest level. The storage volume between this maximum reservoir level (MWL) and the FRL is
called the surcharge storage, which exists only during a flood (where the spillway gates are
opened to pass the flood water) and can not be retained for later use. When the floods subside,
again the spillway gates are closed to conserve water upto FRL. The spillway has to pass the
design flood with the head H = MWLFRL.
Water stored during floods in the permeable banks of the reservoir is called bank stor-
age and drains out when the water level is lowered. The water stored in a natural stream-
channel is called valley storage and is a variable volume. From the point of flood control, the
effective storage in the reservoir = useful storage + surcharge storage natural valley storage.
In the case of shallow and narrow rivers, the velocity will be high ; the water surface
during high flows may be steep (with considerable amount of wedge storage) and the water
surface profile (back water curve) can be computed by the non-uniform flow equation (for a
given inflow rate and the reservoir elevation at the dam). Fron this the information regarding
the water surface levels at various points along the stream, submergence of lands, roads, bridges,
and other strategic structures for which compensation has to be paid, the acquisition of lands,
etc., can be obtained.
Example C-1 (a) The runoff data for a river during a lean year along with the probable de-
mands are given below. Can the demands be met with the available river flow ? If so, how ?
(b) What is the maixmum uniform demand that can be met and what is the storage
capacity required to meet this demand ?
Month : J F M A M J J A S O N D
River flow
(Mm
3
) 135 23 27 21 15 40 120 185 112 87 63 42
Demand
(Mm
3
) 60 55 80 102 100 121 38 30 25 59 85 75
Solution (a) Evaporation losses and the prior water rights of the downstream user are not
given and hence not considered. The computation is made in Table C-1. Since the cumulative
surplus is more than the cumulative deficit the demands can be met with the available river
flows, by constructing a reservoir with minimum storage capacity of 352 Mm
3
, which is also
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 427
APPENDICES 427
the maximum departure of the mass curves (from the beginning of the severe dry period) of
inflow and demand, Fig. C-6.
Table C1 Reservoir storage for the variable demand. (Example C1)
Inflow Cumu- Demand Cumu- Surplus Cuma- Deficit Cumu-
Month (Mm
3
) lative (Mm
3
) lative (Mm
3
) lative (Mm
3
) lative Remarks
inflow demand surplus deficit
(Mm
3
) (Mm
3
) (Mm
3
) (Mm
3
)
Jan. 135 (870) 60 (830) 75 75 (Reservoir full
by end of Jan).
Feb. 23 23 55 55 32 (Start of dry
period)
March 27 50 80 135 53
April 21 71 102 237 81
May 15 86 100 337 85
June 40 126 121 458 81 332 (Max. draft
July 120 246 38 496 82 = storage)
Aug. 185 431 30 526 155
Sept. 112 543 25 551 87
Oct. 87 630 59 610 28 352
Nov. 63 693 85 695 22
Dec. 42 735 75 770 33 55
Total 870 427 387
Reservoir
full on Feb 1
(beginning
of dry
period)
332 Mm
(= Storage
capacity)
3
Mass curve
of inflow
Reservoir
full on Oct. 7
Mass curve
of demand
(variable)
Max draft on
Jan 31
st
C
u
m
u
l
a
t
i
v
e
i
n
f
l
o
w
,
d
e
m
a
n
d
(
M
m
)
3
1000
900
800
700
600
500
1000
400
300
200
100
0
F M A M Jn Jl
Months
A S O N D (J)
Fig. C-6 Mass curves for storage capacity (Example C-1)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 428
428 HYDROLOGY
In the bar graph (Fig. C-7), the monthly inflow and demand are shown by full line and
dashed line, respectively. The area of maximum deficit (i.e., demand over surplus) is the stor-
age capacity required and is equal to 332 Mm
3
.
Surplus
Sur
plus
(b) 276.5 Mm
= Storage reqd.
(to meet the uniform
demand)
3
Monthly
demand
(a) Deficit
= Storage
332 M.m
3
Uniform demand
of 725 M.m
3
Monthly inflow
Inflow
Demand (variable)
Uniform demand
J F M A M Jn A S O N D
(Months)
200
160
120
80
40
0
I
n
f
l
o
w
,
D
e
m
a
n
d
(
M
m
)
3
Jl
Fig. C-7 Bar-graph for storage capacity (Example C-1)
(b) The cumulative inflow in the lean year is 870 Mm
3
. The maximum uniform demand
that can be met is
870
12
= 72.5 Mm
3
per month. In the bar graph (Fig. C-7), the line of uniform
demand is drawn at 72.5 M.m
3
/month. The shaded area represents the surplus over the uni-
form demand (during the months of January, and July to October), which is the storage capac-
ity required to meet the uniform demand, and is equal to
(135) + (120 + 185 + 112 + 87) 72.5 5 = 276.5 Mm
3
Example C-2 The following are the data for a proposed medium size reservoir in
Maharashtra. Determine LSL, FRL, HFL (MWL). What is the total length of the spillway fitted
with crest gates assuming a pier width of 1.5 m (10 m span), flood detention of 4 hr and C = 2.2.
Catchment area 1200 km
2
Rainfall of 75% dependability 900 mm
Gross commanded area 25000 ha
Crpping pattern (proposed) and their water requirement ()
(i) Kharif : Jowar30% (0.45 m), Cotton15% (0.75 m),
Rice10% (1.20 m), Sugar cane10% (1.90 m)
(ii) Rabi: Rice20% (1.20 m), Wheat20% (0.45 m)
(iii) Hot Weather: Vegetables20% (0.60 m)
Area Capacity of Reservoir Site
Contour RL (m) 471 475 495 500 505
Area (ha) 0 36 178 242 323
Capacity (Mm
3
) 0 0.90 19.35 29.85 43.98
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 429
APPENDICES 429
Contour RL (m) 530 535 540 545
Area (ha) 841 1002 1224 1480
Capacity (Mm
3
) 186.62 232.69 288.34 355.95
River bed level 471.0
Top of bund level (TBL) 550.0
Silt load (expected) 250 m
3
/km
2
/yr with a life of 100-yr.
Evaporation losses 1.5 m over the mean area
Empirical formula for yield and
flood of the region Inglis formula.
Solution (a) Yield from the basin :
Dependable runoff R =
( . ) P P 17 8
254
Inglis formula
P = 95 cm, R =
( . ) 90 17 8 90
254

= 25.6 cm
Yield = AR = 1200 10
6
(0.256) = 307.2 10
6
m
3
= 307 Mm
3
.
(b) Irrigation water requirement:
(i) Kharif: Jowar 25000 0.3 0.45 = 3380 ha-m
Cotton 25000 0.15 0.75 = 2820 ha-m
Rice 25000 0.10 1.20 = 3000 ha-m
Sugarcane 25000 0.10 1.90 = 4750 ha-m
13950 ha-m
(ii) Rabi: Rice 25000 0.20 1.20 = 6000 ha-m
Wheat 25000 0.20 0.45 = 2250 ha-m
8250 ha-m
(iii) Hot weather:
Vegetables 25000 0.20 0.60 = 3000 ha-m
Total for the three crop seasons = 25200 ha-m.
Allowing 20% for conveyance losses, 10% for evaporation and seepage losses in the res-
ervoir, 5% for overlap, and 5% as carryover storagea total of 40%.
Live storage = 25200 1.40 = 35280 ha-m or = 352.8 Mm
3
While the annual yield is only 307 Mm
3
which limits the area irrigated unless supple-
mented by natural rainfall. Hence, a live storage of 307 M.m
3
is possible. Curves of eleven. vs.
capacity and eleven. vs. water spread area are shown in Fig. C-4.
Dead storage = 250 1200 100 = 30 10
6
m
3
or 30 Mm
3
for which from the elevn-capacity curve, the lowest sill level of the sluice, LSL = 500.00 m
Gross storage = Dead storage + Live storage = 30 + 307 = 337 Mm
3
for which from the elevn-capacity curve, the full reservoir level
FRL = 543.50 m
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 430
430 HYDROLOGY
Allowing a flood lift of 3 m, the maximum water level (MWL) or
HFL = 546.50 m
With a freeboard of 3.5 m, top of bound level or top of dam, TBL or
TOD = 550.00 m
Height of dam = TOD RBL = 550.00 471.00 = 79 m
Length of spillway
Assuming the crest of the spillway is at FRL, the head on the spillway.
HFL FRL = 546.5 543.5 = 3 m
Effective length of spillway per span
L
e
= L

0.1 nH
= 10 0.1 2 3 = 9.4 m
Discharge over spillway per span
q = CL
e
H
3/2
= 2.2 9.4 3
3/2
= 108 cumec/span
Flood absorbing capacity
FAC = Capacity at HFL capacity at FRL
= 374337 = 37 Mm
3
Spillway design flood, Q
D
= MPF
FAC
T
where T = flood detention time in the reservoir and usually varies between 2
1
2
to 16 hr, and
here given as T = 4 hr. The maximum flood discharge (MPF) may be calculated from the Inglis
formula applicable for the region.
MPF
124
10 24
A
A + .

124 1200
1200 10 24

.
4280 cumec
Q
D
= 4280
37 10
4 60 60
6


= 1710 cumec
No. of spans required =
1710
108
= 15.8, say, 16.
Total length of spillway = 16 10 + 1.5 15
spans piers
= 182.5 m
This length of the spillway can be reduced if the spillway crest (i.e., the sill of the crest
gates) is kept at R.L. 542.50 m, so that the crest gates (height = 4 m) conserve water upto R.L.
543.50 m (FRL) or even above this level, as the floods subside (i.e., towards the end of flood
season).
H = 546.5 542.5 = 4 m
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 431
APPENDICES 431
q = 2.2 9.4 4
3/2
= 165.5 cumec/span
FAC = 374 322.5 = 51.5 M.m
3
(since when the floods are forecast, the FRL is lowered to the spillway crest level by opening
the crest agates)
Q
D
= 4280
515 10
4 60 60
6
.

= 700 cumec
No. of spans required =
700
1655 .
= 4.23, say 5 spans
Total length of spillway = 5 10 + 1.5 4 = 56 m
The various control levels are shown in Fig. C-5.
The flood absorption capacity thus reduces the peak of the MPF. Actually the MPF
hydrograph into the reservoir (inflow hydrograph) is first obtained and then routed (for an
assumed elevn of spillway crest, RL of sluice outlets) by making use of elevn-capacity-dis-
charge relationship, and the peak of the outflow hydrograph thus derived gives the spillway
design flood. For small reservoirs (catchment area < 100 km
2
) the flood absorbing capacity is
neglected as additional safety factor.
Assignment Problem
For the peak of the outflow hydrograph obtained by routing (by modified Puls method) the
hydrograph of inflow into the reservoir in Example 9.1, determine the length of spillway assuming
C = 2.2 (Note: Max. pool elevn. reached = 113.6 m, and elevn. of spillway crest = 112.3 m).
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
When a well in an extensive confined aquifer is pumped at a constant rate, water is
released from storage within the aquifer due to decompression as the piezometric head is
reduced and the radius of influence increases, with respect to time. Assuming that the velocity
of flow in the aquifer as horizontal, the differential equation in polar coordinates can be written
as

2
2
1 h
r r
h
r
+ =
S
T
h
r

...(1)
Using the analogy of the above equation to heat conduction, Theis (1935) obtained the
following solution by assuming that h = H at t = 0, and after pumping (at a constant rate Q)
starts, h H as r . The drawdowns at any distance r from the pumping well is given by
s = H h =
Q
T
e
u u
u
4

z
du ...(2)
or, s =
Q
T 4
W(u) ...(3)
and, u =
r S
Tt
2
4
...(4)
W(u) is called the well function and u is called the argument of the well function ; T and
S are the aquifer constants called the transmissibility and storage coefficients. The solution of
Eq. (2) is
s =
Q
T 4
+ + +
L
N
M
O
Q
P
0 577216
2 2 3 3 4 4
2 3 4
. ln
. ! . ! . !
...... u u
u u u
...(5)
The convergent series in brackets is the well function W(u). Both u and W(u) are
dimensionless and the plot of W(u) vs. u on log-log paper is called the Theis Type Curve
(Fig. D-1). The values of W(u) for different values of u are given in Tables (Ferris et al., 1962).
Since W(u) and u are both functions of T and S, Eqs. (3) and (4) can not be solved directly and
special procedures are employed.
Appendix D
UNSTEADY GROUNDWATER FLOW
432
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 433
APPENDICES 433
W(u) vs. u
W(u)
v
10
5
2
1
5
2
0.1
10
4
10
3
2 5 2 5 2 5 10
2
2 5 10
1
1
Fig. D-1 Theis Type-curve for the well function
(a) Theis Graphical Procedure (Theis 1935, Lohman, 1972)
Taking logarithms of Eq. (3),
log s = log
Q
T 4
+ log W(u) ...(6)
From Eq. (4),
r
t
2
=
4Tu
S
...(7)
and taking logarithms of Eq. (7),
log
r
t
2
= log
4T
S
+ log u ...(8)
Since
Q
T 4
and
4T
S
are constants for a particular pumping test, the Eqs. (6) and (8) are
similar. If the field pump-test curve s vs.
r
t
2
and the type curve W(u) vs. u are drawn to the
same scale on log-log paper on separate transparent sheets and superimposed with the
coordiante axes parallel, so that the two curves coincide for some length AB, an arbitrary
match point P is selected, Fig. D-2, and its coordinates are read on both the graphs. From the
match-point coordinates, s,
r
t
2
, W(u), and u, the aquifer constants can be calculated from Eqs.
(3) and (4).
(b) Cooper-Jacob Solution (Modified Theis)
From Eq. (4), it is evident that u decreases as the pumping time t increases. Jacob
(1946, 1950) pointed out that for large values of t and small values of r, u becomes small
enough so that in the convergent series, Eq. (5), the terms after the first two become negligible.
Thus, the drawdown can be expressed as,
s =
Q
T 4


F
H
G
I
K
J
0 577216
4
2
. ln
r S
Tt
after changing into logarithm to base 10 and simplifying
s =
2 3
4
2 25
2
.
log
. Q
T
Tt
r S
, u < 0.01 ...(9)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 434
434 HYDROLOGY
P = Match
B
A
Field curve
W(u) s. u u
1.9
1.5
m /min
2
Type-curve
sheet
r /t
2
Field curve plot sheet
(transparent)
10
5
2
1
5
2
0.335
S
(m)
10
5
2
1
0.1
5 10
2
0.1
W(u)
2 5
10
2
2 5 2 5
10
3
10
4
0.086
0.001 2 5 2 5
0.01 0.1
u
2 5 1
point
Fig. D-2 Match-point coordinates (Theis)
Hence, a plot of s vs. t on a semi-log paper gives a straight line (Fig. D-3). If the drawdown
difference per log-cycle of time is s, then T can be determined from
s =
2 3
4
. Q
T
...(10)
Time-drawdown plot

s = 0.28 m
1 log-cycle
for s = s 10
= 0.28 10
= 2.8 m
t = 37 min
D

for s = 0,
t = 37 10 min
0

10
Semi-log paper
1.6
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.6
1 10 100 1000
1000 8 6 4 2 200 100 8 6 4 3 2 10 8 6 4 3 2 1
Time t, min
37
min
D
r
a
w
d
o
w
n
s
,
m
(
I
n
o
b
s
e
r
v
a
t
i
o
n
w
e
l
l
)
Fig. D-3 Time-drawdown plot (Example D-1)
From Eq. (9), since s = 0 when
2 25
2
. Tt
r S
= 1
S =
2 25
0
2
. Tt
r
...(11)
in which t
0
is the time for s = 0, obtained from the semi-log plot by extending the straight line
to meet the line of zero-drawdown. Thus, the aquifer constants T and S can be determined
from the time drawdown data obtained from a pumping test, on a single well. If there are
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 435
APPENDICES 435
several observation wells, by knowing their drawdown after pumping for a certain time t, the
aquifer constants T and S can be determined by a plot of a distance-drawdown on a semi-log
paper (Fig. D-4). From Eq. (9),
s =
2 3
4
1
2
2
.
log
Q
T
r
r
F
H
G
I
K
J
Semi-log paper
1 log-cycle
s = 3.25 m

r = 210 m for s = 0
0
1 2 3 4 6 8 10 2 3 4 6 8100
2 3 4 6 8
1000
Distance of observation well r (m)
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
D
r
a
w
d
o
w
n
i
n
o
b
s
e
r
v
a
t
i
o
n
w
e
l
l
,
s
(
m
)
1 10 100 1000
Fig. D-4 Distance drawdown plot (Example D-2)
If the drawdown difference per log-cycle of r is s, then T can be determined from
Eq.(10): s =
2 3
4
. Q
T
...(12)
and S from
Eq.(11): S =
2 25
0
2
. Tt
r
...(13)
where r
0
is the distance for s = 0 obtained by extending the straight line plot to meet the line of
zero drawdown.
(c) Theis Recovery Method
If a well is pumped for a time t
1
(when the drawdown is s
1
) and then stopped, the
drawdown goes on decreasing. The residual drawdown s, at time t since pumping stopped, or
t since pumping started (t = t
1
+ t), is equal to the drawdown (s) due to continuous pumping
upto t, minus increase in head (s
r
) due to an equal recharging well since pumping stopped
(Fig. D-5), i.e.,
s = s s
r
...(14)
For small r and large t,
s =
2 3
4
.
log
Q
T
t
t
, u < 0.01 ...(15)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 436
436 HYDROLOGY
Head = h
s
Recovery
s = Residual
drawdown
= H h

s
Recovery
curve
s
1
t = 0
Head = H
Draw-
down
curve
Q Recovery
Time
Pumping
rate
Drawdown
t t
1
t
t = 0
t = t + t
1

Pumping
Fig. D-5 Theis recovery method
A plot of s vs.
t
t
on a semi-log paper gives a straight line plot (Fig. D-6), and if s is
the difference in s per log-cycle of
t
t
, then T can be determined from
s =
2 3
4
. Q
T
...(16)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.1
0.7
0.8
0.9
R
e
s
i
d
u
a
l
d
r
a
w
d
o
w
n
s
(
m
)

1 2 3 4 5 6 8 10 2 3 4 6 8100 200 3 4 6 81000


1000 100 10
1 log-cycle
s = 0.41 m

Residual
drawdown
curve
Semi-log plot
t/t
1
Fig. D-6 Theis recovery curve (Example D-3)
and this value of T can be used as a check on T determined from the drawdown data during
pumping; S can be determined from the value of s
1
when pumping stopped, using Eq. (9), as
s
1
=
2 3
4
2 25
1
2
.
log
. Q
T
Tt
r S
...(17)
In all the above methods, the assumptions made (in addition to those given under steady
groundwater flow in Chapter7) are :
(i) The water comes from storage and is instantaneously released with reduction of
head.
(ii) The diameter of the pumped well is small, i.e., storage in the well can be neglected.
Fairly long time predictions of drawdown (assuming no recharge) can be made from T and S,
by the methods of Theis, modified Theis (Jacob, Chow) and other investigators.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 437
APPENDICES 437
Example D-1 A 200 mm-well is pumped at the rate 1150 lpm. The drawdown data on an
observation well 12.3 away from the pumped well are given below. Determine the transmissi-
bility and storage coefficients of the equifer. What will be the drawdown at the end of 180 days
(a) in the observation well, (b) in the pumped well ? Use the modified Theis method ; under
what conditions is this method valid ?
Time (min): 2 3 5 7 9 12
Drawdown (m): 2.42 2.46 2.52 2.58 2.61 2.63
Time (min): 15 20 40 60 90 120
Drawdown (m): 2.67 2.71 2.79 2.85 2.91 2.94
Solution The time-drawdown plot is shown in Fig. D-3, from which s = 0.28 m per log-cycle
of t, and t
0
(for s = 0) is 37 10
10
min.
T =
2 3
4
2 3 1150 60
4 0 28
. . . /
( . )
Q
s
=

= 0.0125 m
2
/s
or 10.8 10
5
lpd/m
S =
2 25
0
2
. Tt
r
=
2 25 0 0125 10 60
12 3
10
2
. ( . )37
( . )

= 4.12 10
11
(a) Drawdown in the observation well after 180 days,
s =
2 3
4
2 25
2
.
log
. Q
T
Tt
r S
, u < 0.01
s =
2 3 1150 60
4 0 0125
2 25 0 0125 180 86400
12 3 4 12 10
2 11
. ( . / )
( . )
log
. ( . )
( . ) .

= 3.89 m
(b) Drawdown in the pumped well after 180 days
s
w
=
2 3 1150 60
4 0 0125
2 25 0 0125 180 86400
0 100 4 2 10
2 11
. ( . / )
( . )
log
. ( . )
( . ) .

= 5.06 m.
The Jacobs method is valid for
u < 0.01
r S
Tt
2
4
< 0.01
or t >
r S
T
2
0 04 .
>
( . ) .
. ( . )
12 3 4 12 10
0 04 0 0125
2 11

> 1.25 10
5
sec
i.e., instantaneously after pumping starts.
Example D-2 A production well was pumped for 2 hr at a constant rate of 1600 lpm and the
drawdowns in the seven nearby observation wells are given below. Determine the aquifer con-
stants S and T.
Observation well A B C D E F G
Distance from pumped well (m) 5 10 20 40 80 120 200
Drawdown (m) 5.35 4.35 3.35 2.35 1.4 0.8 0.3
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 438
438 HYDROLOGY
Solution The distance-drawdown plot is shown in Fig. D-4 from which s = 3.25 m per log-
cycle of r, and r
0
(for s = 0) is 210 m.
T =
2 3
2
2 3 1600 60
2 3 25
. . ( . / )
( . )
Q
s
= = 0.003 m
2
/s for 2.6 10
6
lpd/m
S =
2 25 2 25 0 03 2 60 60
210
0
2 2
. . ( . ) Tt
r
=

= 0.0011
Example D-3 A 400-mm well was pumped at the rate of 2000 lpm for 200 min and the drawdown
in an observation well 20 m from the pumping well was 1.51 m. The pumping was stopped and
the residual drawdowns during recovery in the observation well for 2 hr are given below. Deter-
mine the aquifer constants S and T.
Time since Residual Time since Residual
pumping stopped drawdown pumping stopped drawdown
(min) (m) (min) (m)
2 0.826 45 0.180
3 0664 50 0.159
5 0.549 55 0.155
10 0.427 60 0.149
16 0.351 70 0.146
20 0.305 80 0.140
25 0.271 90 0.134
30 0.241 100 0.131
35 0.220 110 0.131
40 0.201 120 0.131
Solution The time-residual drawdown data are processed in Table D-1 and the Theis recovery
curve is plotted on a semi-log paper as shown in Fig. D-6.
Table D-1 Theis recovery method, t
1
= 200 min.
Time since Residual Time since pumping Ratio
pumping stopped drawdown started t = t
1
+ t (t/t)
t (min) s (m) (min)
2 0.826 202 101
3 0.664 203 68
5 0.549 205 41
10 0.427 210 21
16 0.351 216 13.5
20 0.305 220 11
25 0.271 225 9
30 0.241 230 7.7
35 0.220 235 6.7
40 0.201 240 6
(Contd.)...
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 439
APPENDICES 439
45 0.180 245 5.45
50 0.159 250 5
55 0.155 255 4.65
60 0.149 260 4.33
70 0.146 270 3.86
80 0.140 280 3.5
90 0134 290 3.22
100 0.131 300 3.00
110 0.131 310 2.82
120 0.131 320 2.66
From the recovery plot, s = 0.41 m per log-cycle of t/t and
T =
2 3
4
2 3 2 000 60
4 0 41
. . ( . / )
( . )
Q
s
= = 0.0149 m
2
/s
= 1.284 10
6
lpd/m,
and S can be obtained from s
1
= 1.51 m after 200 min of pumping as
s
1
=
2 3
4
2 25
1
2
.
log
. Q
T
Tt
r S
log
2 25 4 0 0149 151
2 3 2 000 60
1
2
. ( . ) .
. ( . / )
Tt
r S
=

= 3.69
Antilog of 3.69 = 4898
2 25 0 0149 200 60
20
2
. ( . )
S
= 4898
S = 0.000206
Ground Water Extraction
Excessive lowering of the groundwater table by pumping may result in crop failures, depletion
of a nearby stream by increased percolation losses, salt water intrusion in coastal aquifers,
and occasionally serious settlement of the ground surface.
The natural recharging of ground water regimen can be supplemented by ponding or
water spreading. For confined aquifers or shallow beds where ponding is not practicable, re-
charging is affected by pumping water down the wells at rates rather less than the correspond-
ing withdrawal rates. Mostly recharge water is excess surface water, but industrial waste
water, sewage and uncontaminated cooling water from industrial and airconditioning plants
are used in some countries.
Sea water intrusion in coastal aquifers occurs when permeable formations out crop into
a body of sea water and when there is landward gradient. Intrusion can be controlled by reduc-
ing pumping, by increasing supply or by constructing a physical barrier.
There is need for legislation of groundwater extraction and regulation to check indis-
criminate draining of groundwater resources. Precautions should be taken against pollution of
surface and subsoil waters by enacting legislation.
Tube well schemes may be integrated with the canal irrigation schemes by suitably
spacing them along the drainage lines in the distribution area. The drainage system must be
planned as an integral part of the distribution system in the design stage itself. The drainage
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-1.PM5 440
440 HYDROLOGY
water may be used again by pumping in double and triple cropping as is already in practice in
Krishna and Godavari deltas.
For a detailed study of ground water i.e., Ground Water Survey, Geohydrology and
Tube Wells, and Irrigation Systems, reference may be made for the Authors companion vol-
ume Ground Water 3rd Edn. by the same Publisher.
Assignment Problems
1 A 300 mm production well tapping an artesian aquifer 30-m thick is continuously pumped at
constant rate of 100 m
3
/hr for 1 day and the drawdowns in an observation well at 80 m from the
pumped well are given below. Compute the coefficients of transmissibility, permeability, and
storage of the aquifer. What is the drawdown in the pumping well after 180 days of continuous
pumping assuming no recharge.
Time Drawdown Time Drawdown
(min) (m) (min) (m)
1 0.14 60 0.70
2 0.22 80 0.75
3 0.27 100 0.80
4 0.31 300 0.83
6 0.34 500 1.00
7 0.38 700 1.03
8 0.40 900 1.06
10 0.43 1000 1.08
30 0.60 1440 1.14
(1375 m
2
/d, 45.8 m/d, 1.35 10
4
, ...)
2 A 400-mm-production well penetrating a water table acquifer is pumped at a constant rate of
100 m
3
/hr for a period of 200 days. The drawdowns in three observation wells are given below.
Compute the coefficient of storage and transmissibility of the aquifier.
Observation Well A B C
Distance from pumping well (m) 2 20 200
Drawdown (m) 2.75 1.80 0.90
(977 m
2
/d, 0.11)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
The hydrological methods of flood routing discussed in Chapter9 were based on the
continuity equation in a simplified finite form called the storage equation.
I = O
S
t
+

where I O , are the mean values of inflow and outflow, and S is the increment in storage in
period t.
Flows and elevations within a reservoir were not directly determined but estimated
from flow profiles and rating curves.
A more mathematical method exists, based on the principle of continuity (law of conser-
vation of mass) and energy principle (law of conservation of energy), which permit computa-
tion of stage or discharge hydrographs at any point in the stream, as well as the water surface
profile at any time. The basic differential equations for gradually varied unsteady flow in open
channels are
Continuity eqn. : B

H
t
+

( ) AV
x
= q ...(2)
Energy eqn. :

V
t
+ V

V
x
+
V
A
q = g S S
y
x
f 0

F
H
G
I
K
J

...(3)
where H = water surface elevation
x = distance along channel
B = width of channel at water surface
S
0
= bed-slope of channel
S
f
= friction slope
t = time
y = depth of flow
V = velocity of flow
q = local inflow into channel per unit width
By selecting finite time and space differences and assuming boundary conditions,
numerical solutions of the above basic differential equations can be made by the use of electronic
Appendix E
FLOOD ROUTING BY
CHARACTERISTIC CONCEPTS
441
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 442
442 HYDROLOGY
computers (since the computations are very laborious). The method of characteristics (Abbott,
1966) may be used, for example. This method of routing by characteristic concept is called
hydraulic routing.
Using finite differences, the derivatives in the differential equations are replaced by
difference quotients and the approximate solutions are obtained by solving linear equations
for the desired quantities like water surface elevation, flow velocity, etc. Thus, for the series of
net points shown in Fig. E-1 (a) and substituting in equation (2),
H
p
= H
e
+
1 2
B
t
x
A V A V
t q
B
e
A A B B
c

( ) +
L
N
M
O
Q
P
...(4)
substituting in Eq. (3) and using Mannings formula to define S
f
,
V
p
= V
c
+

t
x

V V
g H H
A B
A B
2 2
2

+
L
N
M
M
O
Q
P
P
( )

2 2
2 3 2
tq V
A
t gV V
R n
AB c
c
c c
+
L
N
M
O
Q
P
| |
( / )
/
...(5)
where | V
c
| = velocity at C ignoring sign
n = Mannings roughness
R = hydraulic mean radius
Knowing the quantities at A, B and C, H
p
and V
p
(i.e., water surface elevn. and flow
velocity at P) can be determined for the interior point P, from Eqs. (4) and (5) by knowing
values at x x and x + x, i.e., towards left and right of the line x. For a point on the boundary
such as a dam different equations must be used.
Applying finite differences to a series of net points shown in Fig. E-1 (b-i), for the right
boundary where the discharge Q is prescribed
H
p
= H
c
+ H
A
H
E
+
1
4
B
t q
t
x
A V A V Q Q
D
D E E A A p c

+ +
L
N
M
O
Q
P
( ) ...(6)
Assuming Q = AV at any point, V
p
=
Q
A
p
p
...(6 a)
For the left boundary Fig. E-1 (b-ii) and prescribed discharge Q and following the same
procedure
H
p
= H
c
+ H
A
H
E
+
1
4
B
t q
t
x
A V A V Q Q
D
D E E A A p c

+ +
L
N
M
O
Q
P
( ) ...(7)
and V
p
=
Q
A
p
p
...(7 a)
At boundary points where the water surface elevation H is prescribed, two equations for
V are needed, to compute V at each t intervals along the x-line, instead of at 2t intervals as
can be seen in Fig. E-1 (a) and (b).
For the right-boundary condition shown in Fig. E-1 (c-i) where H is prescribed and
which is an even-to-odd line, solution of Eq. (3) for V gives
V
p
= V
c
+
c
B
c
(H
c
H
p
) +
1
2

V V
g H H
p c
A c
2 2
2

+
R
S
|
T
|
L
N
M
M
( )
+
U
V
W
+
F
H
G
I
K
J
O
Q
P
P

c A c
c c
AC c
c
c
Q Q
t
x
t gV V
R n
q B
V
A
( )
| |
( / )
/

2
2 3 2
...(8)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 443
APPENDICES 443
A B
P
C
t
t t
t 2 t

x x

x x + x
A
D
C
t

x x x
E
x 2

x
P E P
C A
t

x x +

2 x x +
x

x
D
(a) Interior point P: Q-prescribed Eqs. (4) and (5) for H, V
(i) Right boundary point P
Eqs. (6) and (6a) for H, V
(ii) Left boundary point P
Eqs. (7) and (7a) for H, V
(b) Boundary points : Q-prescribed
t
C

x x x x 2

A
P
(i) Right boundary point P
even to odd line Eq. (8) for V
t
t- t

x
x x + 2 x +

P
x
x

x
(iii) Left boundary point
even to odd line Eq. (8b) for V
t
C

x x x x 2

A
P
x
(ii) Right boundary point P
odd to even line Eq. (8a) for V
t

x
x x +

A
x
C
P
x + 2

x
(iv) Left boundary point P
odd to even line Eq. (8c) for V
(b) Boundary points : H-prescribed
x
(d) The x-t plane
t
2 x

t
t-line
t-line
1 2 3 4
5 6 7 8
9 10 11
12
13 14 15 16
17 18 19 20
t t
t 2 t

t t
t 2 t

t t

t t

t t

Fig. E-1 Net points in finite difference schemes


DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 444
444 HYDROLOGY
where
c
=
g
A B
c c
and for the right boundary odd-to-even line, with H prescribed, Fig. E-1 (c-ii), use Eq. (8)
with

t
x
replaced by 2

t
x
...(8a)
At the left boundary even-to-odd line with H prescribed, Fig. E-1 (c-iii), use Eq. (8)
with
c
replaced by
c
and

t
x
by

t
x
...(8 b)
and for the left-boundary odd-to-even line, with H prescribed, Fig. E-1 (civ) use Eq. (8)
with
c
replaced by
c
and

t
x
replaced by 2

t
x
...(8 c)
Because of the characteristics of the two basic differential equations used to derive Eqs.
(4) to (8 c), a maximum permissible ratio for making the computations from time t to t + t, is
given by the inequality

t
x

1
V c +
...(9)
where c is the celerity of small waves given by c = gy
m
,
where y
m
= mean depth of the river. For example, if y
m
= 10 m, V = 1.6 m/s, c = 9 81 10 . =
9.92 m/s and

t
x
< 0.087 s/m.
Computational Procedure
Starting with nearly steady conditions, Q and H must be known (or assumed) for all net points
along two consecutive t-lines, say point 18, in Fig. E-1 (d). Values of V (= Q/A) should be
computed for the points 1-8.
Suppose for the right boundary H is prescribed, and for the left boundary Q is pre-
scribed. Based on the values of points 2, 5 and 6, values of H and V at point 10 can be computed
by Eqs. (4) and (5). Similarly, H and V at point 11 can be computed based on values at points 3,
6 and 7. This procedure can be continued for an indefinite number of interior points along the
x-axis for a particular t-line.
At the left boundary where Q is presecribed using values at points 1, 2, 5 and 10, H at
point 9 can be computed by Eq. (7) and V = Q/A.
At the right boundary where H is prescribed, using values at points 7 and 8, V at point
12 can be computed by using odd-to-even line Eq. (8a). By using values at points 11 and 12, V
at point 16 can be computed by using even-to-odd line Eq. (8).
Following the above computational procedure, values of H and V at points on successive
t-lines can be computed.
The product x. H gives changes in storage for the continuity equation. The Mannings
roughness n can be determined from steady flow profiles. Local inflow can best be determined
by stream gauges on tributaries, and from rainfall using unit hydrographs.
Despite the difficulties in the determination of the parameters like A, R, n, c, etc., the
methods that have been developed from the characteristic concepts have shown increasing
utility.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
The hydrologic equation is nearly a statement of the law of conservation of matter and
is given by
Inflow = Outflow + Storage
i.e., during a given time the total inflow to a given area must equal the total outflow plus the
charge in storage.
The items of inflow (into a basin or sub-basin) are :
(i) Precipitation (P) (ii) Surface inflow (Q
i
)
(iii) Subsurface inflow (G
i
) (iv) Imported water or sewage (piped or
channeled into the basin)
The items of outflow (from the basin or sub-basin) are:
(i) Surface outflow (Q
0
) (ii) Subsurface outflow (G
0
)
(iii) Evaporation (iv) Transpiration
(v) Evapo-transpiration (E
t
) (vi) Exported water or sewage (piped or
channeled out of the basin)
The items of storage are:
(i) Change in ground-water storage (GWS)
(ii) Change in soil-moisture storage (SMS)
(iii) Snow cover (d
s
)
(iv) Surface storage (reservoir)
(v) Depression storage (puddles or depressions)
(vi) Detention storage (if not in channels)
(vii) Channel storage (valley storage)
The water balance of a basin (or sub-basin) states that in a specified period of time all
water entering a basin must be consumed, stored or go out as surface or subsurface flow.
Water balance for a given basin should be worked out for a sufficiently long period so that the
various items approach a steady state average conditions and allow direct determination of as
many items in the equation as possible. For example, a study of the water balance of Ganga-
Appendix F
HYDROLOGIC EQUATION AND
WATER BALANCE
445
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 446
446 HYDROLOGY
Ramganga Doab (area = 1.63 M.ha) in U.P. was conducted by A Satish Chandra and Saxena
(1975) for the year 1971-72 and the results obtained are given below:
Inflow
M.ha-m
(i) Precipitation (P) 1.77
(ii) Surface and subsurface
inflow (Q
i
+ G
i
) 0.09
Total 1.86
Outflow
(i) Stream flow (Q
0
) 0.98
(ii) Evapotranspiration (E
t
) 0.80
(iii)Subsurface outflow (G
0
) negligible
(iv) Change of storage (S) 0.07
(v) Other losses 0.01
Total 1.86
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Example G-1 Rainfall occurs on a basin of 288 km
2
at a uniform rate of 25 mm/hr for 4 hours.
The loss rate may be assumed at an average of 5 mm/hr. The mean values of the streamflow for
the successive 4-hr periods are 414, 686, 458, and 238 cumec, respectively. A constant base flow
of 50 cumec may be assumed. Determine the set of distribution percentages on the basis of a
unit period of : (a) 4-hr, (b) 2-hr.
Solution (a) 4-hr distribution graph percentages (Bernard) : The mean D.S.R. for the successive
4-hr periods may be obtained by deducting the constant base flow of 50 cumec as 364, 636, 408
and 188 cumec.
The percentage which runs off
during the 1st 4-hr period =
364
364 636 408 188 + + +
100
=
364
1596
100 = 22.8%
for the 2nd 4-hr period =
636
1596
100 = 39.9%
for the 3rd 4-hr period =
408
1596
100 = 25.6%
for the 4th 4-hr period =
188
1596
100 = 11.7%
Total 100.0
Thus, for a 4-hr distribution graph, the percentages are: 22.8, 39.9, 25.6, 11.7.
(b) 2-hr distribution graph percentages (S-curve technique):
First the S-hydrograph is derived by applying the 4-hr set of distribution percentages to
a succession of 4-unit storms (to produce constant outflow) (Table G-1). The S-hydrograph is
plotted with mean ordinates of 22.8, 62.7, 88.3, and 100.0 for the successive 4-unit peridos
(Fig. G-1). The mean ordinates of the S-hydrograph for the successive 2-hr periods are meas-
ured from the graph. The S-hydrograph is lagged by 2-hr (unit period of the required distribu-
tion graph). The mean difference between the two S-hydrographs for successive 2-hr periods
gives the distribution percentages of the required 2-hr distribution graph as 10, 23, 21, 17, 13,
9, 5, 2. See also Example 5.6 and Table 5.7.
Appendix G
DISTRIBUTION PERCENTAGES FOR
DIFFERENT UNIT PERIODS
447
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 448
448 HYDROLOGY
4
-
h
r

u
n
i
t
4
-
h
r

d
i
s
t
r
i
b
u
-
U
n
i
t

S
t
o
r
m
s
S
-
c
u
r
v
e

m
e
a
n
2
-
h
r

u
n
i
t
S
-
c
u
r
v
e

m
e
a
n
2
-
h
r

l
a
g
g
e
d
S
-
c
u
r
r
v
e

d
i
f
f
e
r
e
n
c
e
p
e
r
i
o
d
s
t
i
o
n

g
r
a
p
h
o
r
d
i
n
a
t
e
s
p
e
r
i
o
d
s
o
r
d
i
n
a
t
e
s
S
-
c
u
r
v
e
=

2

h
r
-
d
i
s
t
r
i
b
u
t
i
o
n
p
e
r
c
e
n
t
a
g
e
s
1
2
3
4
(
t
o
t
a
l
)
(
f
r
o
m

g
r
a
p
h
)
o
r
d
i
n
a
t
e
s
g
r
a
p
h

p
e
r
c
e
n
t
a
g
e
s
1
1
0

1
0
1
2
2
.
8
2
2
.
8
2
2
.
8
2
3
3
1
0
2
3
3
5
4
3
3
2
1
2
3
9
.
9
3
9
.
9
2
2
.
8
6
2
.
7
4
7
1
5
4
1
7
5
8
4
7
1
1
3
3
2
5
.
6
2
5
.
6
3
9
.
9
2
2
.
8
8
8
.
3
6
9
3
8
4
9
7
9
8
9
3
5
4
1
1
.
7
1
1
.
7
2
5
.
6
3
9
.
9
2
2
.
8
1
0
0
.
0
8
1
0
0
9
8
2
T
o
t
a
l
1
0
0
T
a
b
l
e

G
-
1

G
i
v
e
n

a

4
-
h
r

d
i
s
t
r
i
b
u
t
i
o
n

g
r
a
p
h
,

t
o

d
e
r
i
v
e

a

2
-
h
r

d
i
s
t
r
i
b
u
t
i
o
n

g
r
a
p
h
,

F
i
g
.

G
-
1
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 449
APPENDICES 449
S-Curve
lagged by 2 hr
S-curve differences
give 2-hr distribution
percentages
2 hr unit periods
4 hr unit periods
S-Curve
2-hr mean
ordinates
4-hr mean
ordinates
100
90
80
70
60
50
40
30
20
10
0
0 2 4 6 8 10 12 14 16
1 2 3 4 5 6 7 8
1
2
3
4 Time (hr)
D
i
r
e
c
t
s
u
r
f
a
c
e
r
u
n
o
f
f
i
n
p
e
r
c
e
n
t
o
f
(
i
n
e
t
)
Fig. G-1 Derivation of 2-hr distribution percentages (Example G-1)
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
Length
1 in = 2.54 cm
1 ft = 30.48 cm
1 mi = 1.609 km
1 m = 3.281 ft
1 km = 0.6214 mi
= 0.54 nautical mile
1 naut mile = 1.852 km
Volume
1 cft = 28.32 lit
= 0.02832 m
3
= 6.24 imp. gal
= 7.48 US gal
1 imp. gal = 1.2 US gal
= 4.546 lit
1 US gal = 0.833 imp. gal
= 3.79 lit
1 m
3
= 35.315 cft
= 220 imp. gal
= 264 U.S. gal
= 1000 lit
1 cc = 0.061 in
3
1 acre-ft (aft) = 43560 cft
= 1233.5 m
3
= 2.71 10
5
imp. gal
1 km
3
= 0.811 million aft (M. aft)
Appendix H
UNIT CONVERSION FACTORS
450
1 ha-cm = 100 m
3
1 Mm
3
= 810.7 aft
1 aft = 0.123 ha-m
= 1230 m
3
= 2.71 10
5
imp. gal
Area
1 in
2
= 6.452 cm
2
1 ft
2
(sft) = 0.0929 m
2
1 cm
2
= 0.155 in
2
1 m
2
= 10.76 ft
2
1 acre = 0.4047 ha
= 4047 m
2
= 43560 sft
1 ha = 10
4
m
2
= 100 acres
= 2.471 acres
1 are = 100 m
2
1 km
2
= 100 ha
= 247 acres
1 mi
2
= 2.59 km
2
= 640 acres
Velocity
1 ft/sec (fps) = 30.48 cm/s
1 m/sec = 3.281 fps
1 mph = 1.467 fps
= 1.609 kmph
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 451
APPENDICES 451
= 0.8684 knot
1 knot = 1.69 fps
= 0.515 m/sec
1 kmph = 0.2778 m/s
= 0.9113 fps
= 0.6214 mph
1 m/day = 22.9 gpd/sft
Acceleration due to gravity (g)
g = 32.2 ft/s
2
= 981 cm/s
2
= 9.81 m/s
2
Flow rate (discharge)
1 cfs (cusec) = 0.0283 cumec (m
3
/s)
= 28.3 lps
= 449 US gpm
= 374.03 imp. gpm
= 1.983 aft/day
= 724 aft/year
1 m
3
/sec = 35.31 cfs
= 19.01 10
6
imp. gpd
= 13200 imp. gpm
= 15800 US gpm
= 70 aft/day
1 m
3
/day = 2190 imp. gpd
1 mgd (imp.) = 695 imp. gpm
= 3160 lpm
= 0.0527 m
3
/s
1 aft/day = 188.57 imp. gpm
= 271542 imp. gpd
= 1233.5 m
3
/day
1 US gpd = 4.38 10
8
m
3
/s
1 US gpm = 6.31 10
5
m
3
/s
1 imp. gpm = 7.57 10
5
m
3
/s
1 cfs 1 acre-in/hr
Force
1 kg
f
= 9.81 N
= 2.205 lb
Work or Energy
1 m-kg
f
= 9.81 N-m (Joule)
Power
1 m-kg
f
/sec = 9.81 N-m/s (watt)
1 metric hp = 736 watt
= 0.736 kW
Dynamic viscosity
1 1b-sec/ft
2
= 478.8 poise (P)
1 kg
f
-sec/m
2
= 9.81 N s/m
2
= 98.1 poise
1 N s/m
2
= 10 poise
= 1000 centi-poise (cP)
Kinematic viscosity
1 ft
2
/sec = 0.093 m
2
/sec
= 929 stoke (St)
1 m
2
/sec = 10
4
stoke
= 10
6
centi stoke (c St)
Permeability
1 cm/sec = 864 m/day
1 lpd/m
2
= 1.16 10
6
cm/sec
1 m/day = 1.16 10
3
cm/sec
= 1000 lpd/m
2
= 20.44 gpd (imp.)/sft
= 24.54 gpd (US)/sft
Water quality
1 grain/U.S. gal = 17.1 ppm
1 ppm = 1 mg/l
1 taf = 735 ppm
1 me/1 = 1 epm
1 ppm = 1.56 mho/cm
TDS in ppm = 0.64 EC in mho/cm
Temperature
(F 32)
5
9
= C
460 + F = R
273 + C = K
Transmissibility
1 m
2
/day = 67.05 imp. gpd/ft
= 80.52 US gpd/ft
= 0.056 US gpm/ft
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\APP-2.PM5 452
452 HYDROLOGY
Pressure
1 atm = 1 bar
= 1 kg
f
/cm
2
= 14.5 psi
= 30 in of Hg
= 76 cm of Hg
= 34 ft of water
= 10
5
Pa
1 Pa = 1 N/m
2
1 bar = 10
5
N m
2
= 100 KN/m
2
= 10
5
pa
milli =
1
1000
micro = 10
6
hecto = 10
2
kilo = 10
3
mega = 10
6
1 million = 10
6
1 lakh = 10
5
1 micron ( m) =
1
1000
mm
= millionth of a meter
= 3.1416 ....
e = 2.7183 ... .
log
10
e = 0.4343
log
e
10 = 2.303
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
1 Buragohain, P.C., M.E. Dissertation, University of Roorkee, U.P., 1976.
2 Carter R.W. and Godfrey, R.G., Storage and Flood Routing, USGS Wat. Sup. Paper 1543-B, p.
93, 1960.
3 Chander S., et. al., An approach to Flood Stage Forecasting, Water for Human Needs, Proc. of
the 2nd World Congr. on Wat. Res., Vol. V-Technology and Ecology, IWRA and CBIP, New Delhi,
Dec. 12-16, 1975.
4 Clark C.O., Storage and the Unit Hydrograph. Trans. ASCE, Vol. 110, p. 1419, 1945.
5 Corps of Engineers. Flood Hydrograph Analysis and Computations. Manuals EM 111021405,
August 1959.
6 Crawford N.H. and Linsley R.K., Digital Simulation in Hydrology: Stanford Watershed Model
IV, Tech. Rept. 39, Dept. of Civil Engg., Stanford University, 1966.
7 Dooge J.C.I. A General Theory of Unit Hydrographs. Journ. of Geoph. Res., Vol. 64, No. 2, pp.
241-256, 1959.
8 Emir Zelenhasic Theoretical Probability Distributions for Flood peaks. Hydr. paper No. 42, Colo-
rado State University, Fort Collins, Colorado, 1970.
9 Fiering, et al., Synthetic Stream flows. Wat. Res. Manograph No. 1 Am. Geophy. Un. 1971.
10 Eleming G., Deterministic Simulation in Hydrology. American Elsevier, New York. 1974.
11 Hurst H.E., Long-term Storage Capacity of Reservoirs, Trans. ASCE, Vol. 116, pp. 770-808, 1951.
12 Klemes V., The Hurst Phenomenon-a Puzzle ? Wat. Res. Research 10, pp. 675-689, 1974.
13 Longbein W.B., Annual Floods and Partial Duration Series. Trans. Am. Geoph. Un., Vol. 30, No.
6, pp. 879886, Dec. 1949.
14 Linsley R. and Crawford N., Continuous Simulation Models in Urban Hydrology. Geoph. Research
Letters, 1, 1, pp. 59-62, 1974.
15 Matalas N.C., Autocorrelation of Rainfall and Stream Flow Minimums, USGS Prof. Paper 434-
B. 1963.
16 Matalas N.C., Assessment of Synthetic Hydrology. Wat. Res. Research Vol. 3, No. 4, pp. 937-945,
1967.
17 Mc Carthy G.T., The Unit Hydrograph and Flood Routing. Unpublished paper presented at the
conference of the North Atlantic Division, Corps of Engineers, US Army, New London, Conn.
June 24. 1938. Printed by US Engr. Office, Providence RI.
18 Nash J.E., Determining Runoff From Rainfall. Proc. Inst. of Civ. Engrs. Vol. 10, p. 163, 1958.
19 Nash J.E., Systematic Determination of Unit Hydrograph Parameters. Journ. Geoph. Res., Vol.
64, p. 111, 1959.
20 Nash J.E., A unit Hydrograph Study with particular Reference to British Catchments. Proc.
Inst. of Civil Engrs. London, Vol. 17, pp. 249-282, 1960.
SELECTED REFERENCES
453
C-9\N-HYDRO\SEL-REF.PM5 453
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\SEL-REF.PM5 454
454 HYDROLOGY
21 Nash J.E. and Sutcliffe J.V., River Flow Forecasting Through Conceptual Models Part I-A: Dis-
cussion of Principles, Journ. of Hydr. Vol. 10, pp. 317-329, 1970.
22 Rainbird A.F., Methods of Estimating Area Average Precipitation Reports on WMO/IHD Projects,
Rept. No. 3, Secretariat of the WMO, Geneva, 1967.
23 Sharma H.D. et. al., Stochastic Modelling for Flood Flows. Water for Human Needs. Proc. of the
2nd World Congress on Wat. Res., Vol. V-Technology and Ecology. IWRA & CBIP, New Delhi,
pp51-60, Dec. 1975.
24 Sinha U.N., Flood Forecasting in IndiaA Mathematical Model. Math Modelling for Simul. and
Soln. of Wat. Res. Probs., Proc. Symp. Bihar College of Engineering Patna, April 15-17, 1976.
25 Snyder F.F., Synthetic Unit Hydrographs. Trans. Am. Groph, Un., Part I, pp. 447-454, 1938.
26 Snyder W.M., Hydrograph Analysis by Method of Least Squares Proc. ASCE Vol. 81, Sep. 793,
Sept. 1955.
27 Soil Conservation Service National Engineering Handbook, Section 4, Hydrology, 1971, 1972.
28 Statistical Methods in Hydrology. Proc. of Hydr. Symp., No. 5, Mc Gill University, Feb. 24-25,
1966.
29 Tiruvengadachari, S. et. al., Flood in Cauvery Basin. Magnitude and FrequencyProc. of the
National Symp. on Hydr., Nov. 13-15, 1975, University of Roorkee, U.P.
30 Todorovic P., On Some Problems Involving Random Number of Random vaiables. Annals of
Mathematical Statistics, Vol. 41, No. 3, 1970.
31 Water For Human Needs Proc. of the 2nd World Congr. on Wat. Res., Vol. V-Technology and
Ecology. IWRA and CBIP, New Delhi, Dec. 12-16, 1975.
32 A Uniform Technique for Determining Flood Flow Frequencies. Hydrol. Comm., Water Resourc.
Counc. Washigton, Bull 15, Dec. 1967.
33 Chow, V.T., A General Formula for Hydrologic Frequency Analysis, Trans. Am. Geophys. Union,
Vol. 32, pp. 231-237, April 1951.
34 Foster H.A., Theoretical Frequency Curves and their Application to Engineering Problems. Trans.
ASCE, Vol. 87, pp. 142-173, 1924.
35 Fuller W.E., Flood Flows. Trans ASCE, Vol. 77, pp. 564617, 1914 and discussions by Allen
Hazen, pp. 628.
36 Kohler M.A., and Linsley R.K., Predicting the Runoff from Storm Rainfall, U.S. Weather Bur.
Res. Pap. 34, 1951.
37 Pearson K., Tables for Statisticians and Biometricians 3rd ed; Cambridge University Press, Lon-
don 1930.
38 Pillai N.N., Journal of Irrigation and Power, pp. 241248 April 1964, New Delhi.
39 Subrahmanyam V.P., Kama Raju M.V. and Ali M.M., Hydrometeorology and Water Balance of
Krishna River Basin. Journal of the Inst. of Engrs. (India), Civil Engg. Divn., Vol. 61, Pt. CI 3,
Nov. 1980, pp. 146-150.
40 Thomas H.A. and Fiering M.B., The Nature of the Storage Yield Function in Operations Re-
search in Water Quality Management, Harvard University Water Program, 1963.
41 Dalrymple T. Regional Flood Frequency, High Res. Board Res. Rep. 11B. pp. 4-20, 1950. The
USGS has summarised flood data and presented regional frequency methods for the US in Wat.
Sup. Pap. 19711989, 1994.
42 Kimball B.F., On Choise of Plotting Positions on Probability Paper. Jour. Amer. Stats. Assoc.,
1960, 55, 291, 546-560.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO\SEL-REF.PM5 455
SELECTED REFERENCES 455
43 Izzard C.F., Hydraulics of Runoff from Developed Surfaces, Proc. Highway Res. Board, Vol. 26,
pp. 129150, 1946.
44 Abbott, M.B., An Introduction to the Method of Characteristics, Thames and Hudson, London
1966.
45 Satish Chandra and R.S. Saksena, Water Balance Study of a Doab in U.P. (India), Second World
Congress on Water Resources, New Delhi, 1975.
46 Rakesh Kumar et. al., Development of REgional Flood Formulae using L-moments for Gauged
and Ungauged Catchments of North Brahmaputra River System, Journ. Inst. of Engrs. (India),
vol. 84, May 2003, pp. 57-63.
47 Nash J.E., The form of instantaneous unit hydrograph, Int. Assn. of Sci and Hydrol, pub. vol. 45,
no. 3, 1957, pp. 114-121.
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C9/N-Hydro\Biblio.pm5
1 Butler S.S., Engineering Hydrology. Prentice-Hall, Inc; Englewood Cliffs, N.J., 1959.
2 Dandeker M.M. and Sharma K.N., Water Power Engineering. Vikas Publishing House Pvt. Ltd;
New Delhi, 1979.
3 Davis C.V. and Sorensen K.E., Hand Book of Applied Hydraulics. McGraw-Hill Book Company,
New York, 1969.
4 Desmukh. M. M., Water Power Engineering. Dhanpat Rai & Sons, Nai Sarak, Delhi, 1978.
5 Flood Control and The Use of Water Resources with special reference to Western India. Proc. of
the Seminar organised by the south Gujarat University, Surat, Jan. 1969. Ed. R.N. Shelat, Dept.
of Civil Engg; S.V. Regional College of Engg. and Tech; Surat. W. India.
6 Linsley K., Kohler A. and Paulhus L.H., Hydrology for Engineers. McGraw-Hill Book Company
Inc. New York 1975.
7 Linsley K., Kohler A., and Paulhus L.H. Applied Hydrology. McGraw-Hill Book Company, Inc.
New York, 1949.
8 Linsley and Franzini., Water Resources Engineering. McGraw-Hill Book Company, New York,
1979, 3 Ed.
9 Nemec, J. Engineering Hydrology. McGraw-Hill Book Company, New York, 1972.
10 Varshney R. S., Concrte Dams. Oxford and IBH Publishing Company, New Delhi, 1978.
11 Ven Te Chow, Ed. Hand Book of Applied Hydrology. McGraw-Hill Book Company, New York,
1964.
12 Wilson E.M., Engineering Hydrology. ELBS and Macmillan, London, 1980.
13 Wisler C.O. and Brater E.F., Hydrology. John Wiley & Sons, Inc. New York, 1959.
14 Ciriani T.A. et. al., Mathematical Models for Surface Water Hydrology. John Wiley & Sons, New
York, 1977.
15 Hammer and Mac Kichan. Hydrology and Quality of Water Resources. John Wiley & Sons, New
York, 1981.
16 Mathematical Modelling for Simulation and Solution of Water Resources Problems. Proc. All
India Symp., April 1517, 1976, Bihar College of Engineering, Patna.
17 Varshney R.S., Engineering Hydrology. Nem Chand & Bros., Roorkee, U.P., 1979, 2nd Ed.
18 Warren Viessmann. et. al. Introduction to Hydrology. IEP: A Dun-Donnelley Publisher, New
York. Copyright by Thomas Y. Crowell Company, Inc., 1977, 2nd Ed.; 3rd Edn. in 1989, Harper
& Roe Publishers, Singapore, Rs. 350.
19 Allen J. Hjelmfelt, JR. & John J., Cassidy, Hydrology for Engineers and Planners, Iowa State
University Press/AMES, Iowa, 1975.
20 Mutreja, K.N., Applied Hydrology, Tata McGraw-Hill Pubishing Co., Lte., New Delhi-110002,
1986, Rs. 236. [NBT Rs. 87]
21 Reginald W. Herschy, Streamflow Measurement, Elsevier Applied Science Publishers, Ltd., Lon-
don & New York, 1985.
BIBLIOGRAPHY
456
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
a.a.r, 4, 23, 24
API, 320
Aquiclude, 192
Aquifer, 192
confined, 197
specific yield, 192
storage coefficient, 194
types, 192
unconfined (water table), 196
Aquiclude, 192
Aquifuge, 192
Aquitard, 192
Area-velocity method, 172, 176, 179
Arid climate, 23
regions, 306
Artesian well, 193
Bank storage, 97, 123, 124
Base flow, 97, 123, 124
Basin, 6, 97
characteristics, 97
compactness coefficient, 99
form factor, 99
lag, 127, 155
mean and median elevation, 101
shapefan, fern, 99
slope, 98, 100
Snyders, 151, 155
Tapthi, 5, 6
Bernards distribution graph, 142, 144, 447
Blaney-Criddle method, 68
California method, 38
Catchment characteristics, 97
circulating ratio, 101
compactness coefficient, 101
drainage density, 98
457
INDEX
elongation ratio, 9, 101
fan-shaped, 99
fern-shaped, 99
form factor, 99
Hortons grid, 100
isochrones, 104, 109
maximum rate of runoff, 111
(flood-rational formula)
mean and median elevation, 101
runoff, 106
from time of concentration, 108
slope, 98
Snyders, 151
stream density, 98
yield, 108, 109, 111
Causerina trees, 65
Cavity wells, 200
yield of, 200
Cetyl alcohol, 65
Check dams, 246
Channel improvement, 241, 244
Clarks model, 149, 355, 397, 400
Climatearid, semi-arid, humid, 23, 306
Cloud seeding, 403
technique, 404
operation, 406
case history (2005), 406
Coaxial correlation (API), 322
Coefficient of flood, 223, 225, 229
of skew, 228, 330
of variation, 228, 329, 330, 332
Correlation coefficient, 317, 318, 324
multiple, 322
Current meter gaugings, 174, 178
mean-section method, 177
mid-section method, 177
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO/IND.PM5
458 HYDROLOGY
Current meter rating, 174
Cyclonic storm, 23
Darcys law, 195
validity of, 196
Density current (reservoirs), 299
Depression storage, 97
Depth-area-duration (DAD) Curves, 11, 33, 35, 36
Design flood, 238
storm, 49, 217
Detention storage, 97
Detention storage, 97
Distribution percentages, 128
to composite runoff, 144-149, 160
computation of stream flow from, 161
Double mass analysis, 24
Drainage divide, 98
density, 98
Drainage net, characteristics of, 98
Drought-duration studies, 287, 332
Dug-cum-borewell, 206
Dupuitts equation, 196
assumptions of, 198
Effluent stream, 103
Ephemeral stream, 103
Encounter probability, 225, 235
Evaporation (lake), 60
Daltons law, 61
estimation, methods of, 62
Blaney-Criddle, 68
Index method, 69
measures to reduce, 64
pans, 62
IMD Land pan, 62
pan coefficient, 63
piche evaporimeter, 63, 64
soil (from), 66
Evapotranspiration, 67
estimation of, 68
factors affecting, 70
Extremal distribution, 333
(EVI, II, III)
f
ave
-index, 82
Field irrigation requirement (FIR), 69
Floats, 173
Floods, 212
design flood, 216, 238
empirical formulae, 213
envelope curves, 214
maximum probable (MPF), 10, 212, 218, 221, 430
peak, estimation of, 213
standard project (SPF), 10, 212, 218, 430
Flood absorption capacity (FAC), 430, 431
Flood control economics, 247, 252
project, 253
Flood control methods, 238
Channel improvement, 241, 244
Cutoff, 244
Combination of, 249
deepening, 244
economics, 247
levees, 241
reservoirs, 239
retarding basins, 240
soil conservation measures, 245
Flood forecasting, 251, 386
by mathematical model, 389
of R. Tapthi, 253
warning system, 253
Flood, maximum, estimation of 213
Creagers formula, 214, 231
Empirical formulae, 213
rational formula, 231
world enveloping formula, 231
Flood frequency, 221
Allen hazen, 38, 222
annual floods (series), 222
California, 38, 222
curves, 341, 358
encounter probability, 225, 235
Fosters, 229
Fuller, 214, 230, 337
Gumbel, 222, 227, 236, 337
Log-Pearson Type-III, 360, 361
partial duration series (PDS), 228, 232
Powell, 341
regional, 361
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO/IND.PM5
INDEX 459
Stochastic method
annual, 344
PDS, 344, 355
Ven Te Chow, 341
Weibull, 222, 230, 235, 236
Flood hydrograph
of R. Tapthi, 12
due to multiple storms, 118, 159
Flow-duration curves, 285
Gamma distribution, 333
Ground water flow, 195
radial flow into well (unsteady), 432
Jacobs method, 433, 433, 435, 437, 438
Dupuitts equation (steady), 196
Theis method, 432, 433
Theis recovery, 435, 436, 438
Reynolds number, for, 196
Gumbel distribution (EV-I), 222, 227, 236, 334, 337
Gumbels probability data, 224
paper, 224, 228
Gumbels method, 222, 227, 236, 337
Hazens method, 38, 222
Hortons constant, 70, 78
determination of, 75, 76
curve (infiltration), 71, 72, 74, 79
equation, 70, 77, 79
grid, 100
method, 75
Hydraulic design, 112
Hydrologic design, 112
Hydrograph, 117
components, 117
distribution percentages, 142, 144, 447
flood (R. Tapthi), 12
due to multiple storms, 118, 159
separation, 122, 125
use, 422
Hydrologic cycle, 11, 12
data, 14
study of Tapti basic, 5-12, 36
of R. Narmada, 9, 36, 364 (Pb. 6)
Hydrology, 1, 11
scope of, 14
Hydrometeorology, 70
Hydrometeorological setup, 70
Hyetograph, 37, 45, 85, 117
Hypsometric curve, 101
Humid climate, 23, 306
region, 309
IMD land pan, 62
Index of wetness, 23
Indian Meteorological Department (IMD), 22
Infiltration, 70
constants, 70, 76, 79
cumulative, 80
curve, 71, 72, 74
indices, 61
f
ave
index, 82
-index, 82, 83
W-index, 82
loss, 82
losses, supra rain technique, 83
rate(f), 81
determination, methods of, 71
Infiltrometer, double ring, 71, 77
tube, 73
Influent stream, 103
Inflection point, 117, 123, 127, 375, 376
Intensity-duration curves, 46
Intensity-duration-frequency (IDF)
of storms, 38, 41, 114
Intensity of design storm, 114, 215, 216
Interception loss, 61, 74
Interflow, 96
Instantaneous unit hydrograph (IUH), 149, 378, 393
determination, methods of, 371, 393
Clarks model method, 397, 398, 400, 401
storage coefficient (K), 375, 399
conceptual models, 373
convolution integral, 372
isochrones (TAD), 377, 400
Nash model, 394
S-curve, 371, 393
Jacobs method, 433-437
Kimballs method (Weibull), 38
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO/IND.PM5
460 HYDROLOGY
Lag time, 127, 155
Lake evaporation, 64
estimation, methods of, 62
measures to reduce, 64
monthly data, 61
Land pan, 62
Levees, 241, 249
Linear regression, 315, 317, 319, 324
multiple, 319, 322
Load curve (power), 291
Load factor, 292
Lognormal distribution, 333
Log-Pearson distribution, 358, 361
Mass curve, of rainfall, 21, 37, 45
of reservoir, 280, 282, 284, 381
Mathematical models, 366
deterministic, 366
empirical, 366
rainfall-runoff, 368, 370
stochastic, 366
watershed, 370
Maximum probable flood (MPF), 10, 212, 218, 221
estimation, methods of, 213
enveloping curves, 215
of R. Tapthi, 217, 221
hydrograph of R. Tapthi, 221
Mean, median and mode (statistics), 327, 328, 331
Moisture adjustment factor (MAF), 10, 217
Multipurpose reservoirs, 424
Muskingum method, 270, 275
Nash model, 394
Normal distribution, 332
Open (dug) wells, construction of, 206
hydraulics, 202
recuperation test, 203
specific yield, 203
yield tests, 202
Overland flow, 13, 96
effect of wind, 420
hydrograph (Izzard), 112, 416, 420
laminar, 112, 413
turbulent, 416
Pan coefficient, 63
Partial duration, curves, 233, 344, 360
series (PDS), 282, 232, 234, 355
Pearsons distribution (Type-III), 334
logarithmic, 335, 358
Phytometer, 67
Piche evaporimeter, 63, 64
Piezometric surface, 193
Plant load factor, 292
Pondage, 288, 290
factor, 288
Porosity, 193
Poisson distribution, 333
Power duration curve, 286, 287
Power output, 283, 289
PMP, 48, 212
Precipitation, 17
adjustment of records, 23
convectional, 17
cyclonic, 17
depth-area-duration curves, 11, 33, 35, 36
depth-duration curves, 11, 46
forms of, 13
frontal, 18
intensity duration curves, 38, 42, 46
length of record, 22
mass curve, 45
measurement of, 18
mean and median, 43
mean areal depth, 26
missing data, 23
orographic, 17
probable maximum (PMP), 49, 212
probability of occurrence, 38, 39, 47
non-occurrence, 39
types of, 17
Radars, 22
Rainfall, a.a.r, 23, 24
frequency curve, 48
mass curve, 21, 37, 45
mean areal depth, 28
moving averages, 48
points, 27
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO/IND.PM5
INDEX 461
Rainfall data, analysis of, 38
double mass, 24, 26
Rainfall records, adjustment of, 23
correlation, 38
departments, 22
length of, 22
missing data, 23
Rainfall-runoff model, 368, 370
Correlation, 107, 317, 320
Raingauge, automatic (recording), 19
density, 22
float type, 20
optimum network, 31, 32
radio reporting, 21
recording, 19
saturated network, 31
Symons (non-recording), 18
tipping bucket, 19, 20
weighing type, 19, 20
Range (statistical), 327, 383, 385
Rational formula (flood), 111, 114, 215, 231
Rational method for yield, 108, 111
Recurrence interval (return period), 38, 42, 48, 214,
215, 222, 224, 228, 231, 233, 337, 339, 343, 358,
360, 361
Recession constant, 118
time, 127
Recession curve, 118, 399
Reservoir, capacity curve, 425
dead storage, 426, 429
design studies, 428
flood absorbing capacity (FAC), 430, 431
live storage, 426
mass curve, 280, 282, 284, 381, 423, 427, 428
multipurpose, 425
reduction in capacity, 300
routing (flood), 263, 269
sedimentation, 298, 300
control, 303
storage capacity, 281, 383, 425, 428
trap efficiency, 301-303
useful life, 302
Residual mass curve, 383, 385
Retarding basins, 240
Rivers, of India, 3
perennial, 4
River basins, of India, 4
River stage recorder (AWLR), 180
Runoff, 77, 82, 83, 96
coefficient, 108
factors affecting, 104
peak rate, 43, 114
Runoff estimation, 106
time of concentration method, 109
empirical formulae, 106, 107
infiltration method, 73, 77, 108
overland flow method, 112, 413, 416
rational method, 108, 111
unit hydrograph method, 113
Runoff river plant, 289
Saltation, reservoirs, 298, 299
Satellite photo, 23
Sedimentation, of reservoir, 298, 300
control, 303
Sediment movement, reservoirs, 298
Semi-arid climate, 23, 306
regions, 307
Sequent peak algorithm, 383, 386
Soil conservation measures, 245
Check dams, 246
Contour farming, 247
Contour trenching, 247
Soil evaporation, 66
Snow, sp. gr., density, 410
Snow line, 411
degree-day factor, 409
Snow melt, 49
physics of, 407
Snow pack, 49, 411
Snow surveying, 409
Specific capacity, tube well, 199
Specific yield, aquifer, 192, 194
open (dug) well, 203
Spillway, crest level, fixing of, 424
length, 430
Spillway design flood, 424
Standard deviation, 328, 330
Standard error of estimate, 304, 319, 386
Standard project flood, 10, 212, 218, 430
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO/IND.PM5
462 HYDROLOGY
Stage-discharge rating curve, 176, 178, 184
adjustment of, 181
extension of, 181
Statistics, elements, 327
mean, median, 43, 44, 327, 328, 331
mode, 328, 331
skew distribution, 328
skewness, 329
coefficient of, 330
variance, 329
Station-year method, 24
Storage capacity, reservoir, 281, 383, 488
Storage coefficient, aquifer, 194
basin, 375, 399
Storm characteristics, correlation of,
depth-duration, 11, 45
intensity-duration, 46
intensity-duration-frequency (IDF), 38, 41, 114
design, 49, 217
track, 9
maximum probable (MPS), 10
Storm maximisation, 10
by moisture charge, 10, 217
by unit hydrograph method, 221
Streams, classification of, 103
effluent, 103
ephemeral, 103
influent, 103
intermittent, 104
perennial, 104
Stream flow components, 96
separation of, 120
Stream flow computation, 171, 185
contracted area method, 172, 186
salt concentration method, 172
slope-area method, 171, 187
Stream gauging, methods of 171
area-velocity method, 172, 176, 179
by current meter, 174, 176
selection of site, 183
Supra-rain technique, 83
curve, 85
Synthetic stream flow, 379
Synthetic unit hydrograph, Snyders, 149
Tank irrigation, 109
length of weir, 111
yield for, 109
Tapti basin, 6
hydrological study, 5-12, 36
Thiessen polygon method, 27, 28
Time-area diagram (TAD), 378, 398, 400
Time of concentration, 109, 398
runoff from, 109, 398
Transpiration, 67
ratio, 67
Transmissibility, 196, 199
Trap efficiency, 301-303
Unit hydrograph, 113, 124, 379
application of, 157, 158, 160
alteration of duration, 136
assumptions of, 113
average, 136
derivation of, 124, 129
from complex storms, 130, 132
dimensionless, 156
elements of, 126
instantaneous (IUH), 149, 379, 393, 401
limitations of, 127
matrix method, 135
propositions of, 127
runoff estimation from, 113
SCS method, 157
synthetic (SUH), Snyders 149
transposing of, 154
Unit storm, 127
Unsaturated flow, 66
Valley storage, 97, 106
Variance, 327
Velocity measurements, 172
Velocity rods, 172
Water balance, 87, 445
of Krishna river basin, 87
Water bearing formations, 192
Water losses, 60
Watershed leakage, 87
DOWNLOADED FROM http://annacivil.tk
A
N
N
A
C
I
V
I
L

B
L
O
G
C-9\N-HYDRO/IND.PM5
INDEX 463
Water resources, Worlds, 1
of India, 1
Well hydraulics, 196
Cavity wells, 200
Dupuitts equations, 196-198
Jacobs equations, 433-438
Open (dug) wells, 202
Thies equations, 432-438
Well interference, 207
Wells spacing, 207
W-index, 82
Yield (see runoff estimation), 106, 429
for tank, 109
rational method for, 106, 108
DOWNLOADED FROM http://annacivil.tk

You might also like