Powered by AI
The document discusses grid couplings, which are used to connect shafts and reduce vibration. They absorb shock loads and compensate for misalignment between connected equipment.

A grid coupling provides benefits such as reducing vibration by up to 30%, cushioning shock loads to protect equipment, being versatile for different configurations, and having quick installation and maintenance.

A grid coupling reduces vibration through the flexible nature of its spring-like grid, which absorbs impact energy by spreading it out over time. As load increases, more of the hub's teeth contact the grid, providing superior protection.

Grid Type

GD
GD-1

Grid Type

Overview

Couplings Reduce Vibration, Absorb Shock


and Compensate for Misalignment.
The Power of Torsional Damping
The Lovejoy G-Type Flexible Grid Coupling reduces vibration by as much
as 30%, and cushions shock loads to safeguard your driving and driven
equipment. The flexible nature of the spring-like grid absorbs impact energy
by spreading it out over time, thus reducing the magnitude of the peak
loads. This is possible because of the progressive contact that occurs
between the curved profile of the hub teeth and the flexible grid. Therefore,
as the load increases, more of the tooth comes into contact with the grid,
thus supplying superior protection and supreme performance.
Lovejoy G-Type Flexible Grid Couplings are designed for versatility.
Common hubs and grids are used within a given size range for both
horizontal and vertical split cover models. Grid installation and replacement is a snap at only a fraction of the complete coupling cost.

HORIZONTALLY SPLIT COVER


Ideal for limited space.
Allows easy access to grid.
Well-suited for reversing service.
Manufactured from die-cast aluminum.

Benefits of the Grid Coupling include:

GD

Our 1000 Series Tapered Grid coupling is fully interchangeable with


industry standards.
Quick installation and easy maintenance reduces labor and downtime
costs.
Torsionally flexible and resilient - reduces vibration, plus cushions shock
and impact loads.
Versatile stock components can be used with either horizontal or vertical
covers. Cover fasteners available in either Metric or Imperial sizes.
High tensile, shot-peened alloy steel grids and precision machined hubs
ensure superior performance and long life.

Top Quality Manufacturing


Made from a high tensile alloy steel, the grid spring is carefully formed to
shape, then hardened and tempered under controlled conditions. Next, the
grids are shot-peened, compressing the surface molecules and leaving a
residually stressed surface. This process creates a stronger surface in
compression.

VERTICALLY SPLIT COVER


Ideal for higher operating speeds.
Manufactured from stamped steel.

Any load applied on the coupling in operation must first surmount the
compressive forces created by peening before the tensile stress reaches
the grid. This provides a dramatic increase in rating over other coupling
types, increases reserve strength for longer life and may permit selection
of a smaller coupling, thus reducing cost.
The Lovejoy Grid spring/hub tooth arrangement has been specifically
designed for optimum performance and supreme reliability. Not only does
the hub tooth profile permit progressive loading under torsional shock
conditions, but unique root radii are incorporated to significantly improve
the fatigue life of the teeth.

! WARNING
You must refer to page iv for Important Safety Instructions and Precautions for
the selection and use of these products. Failure to follow the instructions and
precautions can result in severe injury or death.

GD-2

FULL SPACER DESIGN


Ideal for pump applications because
drop-out section allows for pump servicing.
Used only with horizontally split cover.
Available in sizes 1020-1090.

Grid Type

Selection Process

Grid Coupling Selection Process


The selection process for determining the proper grid coupling size requires
using the charts shown on the following pages. There are three components
to be selected: two hubs and one cover. When the shaft size of the driver
and driven of the application are of the same diameter, the hubs selected
will be the same. When shaft diameters differ, hubs selected will differ
accordingly.
Information necessary before a grid coupling can be selected:
HP (or KW) and RPM or Torque of driver
Shaft sizes and type of fit of driver and driven equipment and
corresponding keyways
Shaft gap
Physical space limitations
Application description
Environmental conditions (i.e. extreme temperature, corrosive
conditions, space limitations)
For applications with high peak loads or brake applications use the formulas
given on page GD-4 or consult Application Engineering for assistance. The
following information is required for high peak loads or brake applications:

System peak torque and frequency


Duty cycle
Brake torque rating

List of Charts provided for Selection:


Chart 1 - Service Factors (pgs. GD-5-6)
Chart 2 - General Service Factors (pg. GD-7)
Chart 3 - Coupling Torque and Horsepower Ratings (pg. GD-7)
Formulas:
Nominal Torque =

in-lb =

(HP x 63025)
RPM

Nm =

(KW x 9550)
RPM

Design Torque = Nominal Torque x Service Factor

Step 1: Determine the Nominal Torque of your application by using the


following formula:
Nominal Torque =

in-lb =
Nm =

(HP x 63025)
RPM
(KW x 9550)
RPM

Step 2: Using the Service Factors Chart 1 (pgs. GD-5-6), select the service
factor which best corresponds to your application. If you cannot
locate a service factor for your application, choose an appropriate
value from the General Service Factors Chart 2 (pg. GD-7).
Step 3: Calculate the Design Torque of your application by multiplying the
Nominal Torque calculated in Step 1 by the Service Factor
determined in Step 2.
Design Torque = Nominal Torque x Service Factor
Step 4: Using the Coupling Torque and Horsepower Ratings Chart 3
(pg. GD-7) scan down the torque rating to the first value that is
greater than or equal to the Design Torque calculated in Step 3.

GD

Steps In Selecting A Grid Coupling


Once this value is located, refer to the corresponding coupling size
in the first column of the Coupling Torque and Horsepower Ratings
Chart 3 (pg. GD-7).
Refer to the maximum RPM value (pg. GD-7) for the torque
capability to ensure that the application requirements are met. If
the requirement is not satisfied at this point, a different cover style
or another type of coupling may be required for the application.
Please consult Lovejoy Application Engineering.
Step 5: Compare the application driver/driven shaft sizes to the maximum
bore size available on the coupling selected. If coupling bore size
is not large enough for the shaft diameter, select the next largest
coupling that will accommodate the driver/driven shaft diameters.
Refer to Chart 3 (pg. GD-7).
Step 6: Using the Item (UPC) Number Selection charts (pgs. GD-8-10),
find the appropriate Bore and Keyway sizes required and locate
the Lovejoy Item (UPC) number. Next locate the appropriate
Lovejoy Item (UPC) number for the Cover/Grid Assembly Kit.

GD-3

Grid Type

Selection Process

Selection Example
A coupling is needed to connect a 50 HP standard electric motor rated at
1800 RPM to a rotary compressor. The shaft size of the electric motor
(driver) is 1.75 inches and the compressor (driven) is 1.5 inches. The shaft
connections are .75 inches long. There are no special environmental
conditions.

GD

Step 1: Determine the Nominal Torque:


Nominal Torque =
in-lb = (HP x 63025)
RPM
in-lb = (50 x 63025)
1800
=
1750.69

Step 5: Compare the application driver/driven shaft sizes to the maximum


bore size available in the coupling selected (pg. GD-7). The
electric motor (driver) of this application has a shaft size of 1.75
inches and the compressor (driven) has a shaft size of 1.5 inches.
The G1050 coupling has a maximum bore of 1.875 inches, so it
can accommodate the driver/driven shaft sizes.
Therefore, the proper coupling size for this application is a 1050
coupling with a horizontal cover.
Step 6: Using the Item (UPC) Number Selection charts (pgs. GD-8-10),
locate the appropriate Lovejoy Item (UPC) numbers.

Step 2: Using the Service Factors Chart 1 (pgs. GD-5-6), select the service
factor which best corresponds to your application. The Service
Factor for an electric motor driving a rotary compressor is 1.25.
The value of 1.25 is found under the application category
Compressor, Rotary, column: Electric Motor in Chart 1.

Locate the Grid Coupling Inch Hubs selection chart (pg. GD-8)
The first bore size to be located is for the 1.75 inch shaft on the
electric motor. Scan down the Bore/Keyway column to the 1.75
inch bore entry. Read across to the 1050 column to locate the
Lovejoy Item (UPC) number of 05483.

Step 3: Calculate the Design Torque of your application :


Design Torque = Nominal Torque x Service Factor
= 1750.69 x 1.25
= 2188.37 in-lb

The second bore size to be located is for the 1.5 inch shaft on the
compressor. Scan down the Bore/Keyway column to the 1.5 inch
bore entry. Read across to the 1050 column to locate the Lovejoy
Item (UPC) number of 05481.

Step 4: Referencing the Coupling Torque and Horsepower Ratings Chart 3


(pg. GD-7), use the Torque Rating column to determine the proper
coupling size. Scanning down the Torque Rating column, the first
entry to accommodate the Design Torque value of 2188.37 in-lb is
size 1050 with a nominal torque rating of 3500 in-lb. The maximum
RPM of 1800 on the electric motor of the application does not
exceed the 4500 RPM maximum allowed for this size with the
horizontal cover.

Locate the Grid Coupling Accessory selection chart (pg. GD-10)


The cover/grid assembly is selected by scanning accross the Grid
Coupling Size row to the 1050 entry. Read down to the Horizontal
Cover/Grid Assembly-Inch row to locate the Lovejoy Item (UPC)
number of 05352.
Each of these item (UPC) numbers should be prefixed with the
Lovejoy Item (UPC) number of 697904.

Selecting A Grid Coupling For High Peak


Loads Or Brake Applications
Use this selection method in the following instances: 1) High Peak Loads
2 ) Brake Applications (A brake is part of the system but it is not part of the
actual coupling.)
Step 1: Calculate the Design Peak Torque using one of the following
equations:
Non-Reversing High Peak Torque =
in-lb =
System Peak Torque
Nm =
System Peak Torque
in-lb = (System Peak HP x 63025)
RPM
Nm = (System Peak KW x 9550)
RPM
Reversing High Peak Torque =
in-lb =
2 x System Peak Torque
Nm =
2 X System Peak Torque
in-lb = (2 x System Peak HP x 63025)
RPM

GD-4

Nm

= (2 x System Peak KW x 9550)


RPM
Occasional Peak Torques (Reversing or Non-Reversing) =
in-lb = 0.5 x System Peak Torque
Nm = 0.5 x System Peak Torque
in-lb = (0.5 x System Peak HP x 63025)
RPM
Nm = (0.5 x System Peak KW x 9550)
RPM
Step 2: If the application is a brake application and the torque rating of the
brake exceeds the motor torque the brake torque needs to used
with the application service factor selected in Chart 1 (pg. GD-6-7).
Design Torque = Brake Torque Rating x Service Factor
Step 3: Once the Design Torque has been determined go through steps 4
through 6 of the selection process on page GD-4 to determine the
proper coupling size.

Grid Type

Selection Data

Service FactorsIndustries

Chart 1

Notes:

Reciprocating
Engines-6 or more Cyl.

2.75

2.25

3.00

2.50

2.00

1.50

2.75

2.25

3.00

2.50

2.00

1.50

2.50

2.00

GD

Aggregate Processing, Cement,


Coilers (Up or Down) Cold
Beater, Pulper, Calender,
Mining Kilns; Tube, Rod and
Mills only, Cooling Beds, Mill
Couch, Cylinder, Dryer, Pulp
Ball Mills
Tables Hot Bed or
Grinder, Fourdrinier, Press,
Dryer, Rotary, Hammermill
Transfer, Non-Reversing ............. 1.50 2.50 2.00
Suction Roll ............................... 1.75
or Hog,Tumbling Mill or Barrel,
Reel Drives, Slitters, Steel Mill
Barker Auxiliary, Hydraulic,
Direct or on L.S. Shaft of Redonly, Wire Drawing Machinery ... 1.75 2.75 2.25
Mechanical, Barking Drum L.S.
Coilers (Up or Down) Hot Mills
Shaft of Reducer with Final
ucer, with Final Drive of Single
only, Coke Plants Door
Drive-Helical or Herringbone
Helical or Herringbone Gears .... 1.75 2.75 2.25
Opener, Drawbench, Furnace
Gear, Cutter, Felt Whipper,
Grizzly, Direct or on L.S. Shaft
Pushers, Hot and Cold Saws,
Jordan, Log Haul ....................... 2.00
of Reducer, with Final Drive
Ingot Cars, Mill Tables Runout,
Barking Drum L.S. Shaft of
of Machined Spur Gears ........... 2.00 3.00 2.50
Non-Reversing, Non-Plugging,
Reducer with Final DriveCrushers, Ore or Stone ............... 2.50
*
*
Screwdown, Seamless Tube
Machined Spur Gear, Chipper ... 2.50
Brewing and Distilling
Mills -Thrust Block, Tube
Barking Drum L.S. Shaft of
Bottle and Can Filling Machines,
Conveyor Rolls, Reeler, Kick
Reducer with Final Drive-Cast
Brew Kettle ................................ 1.00 2.00 1.50
Out, Soaking Pit Cover Drives
Tooth Spur Gear ........................ 3.00
Cookers, Continuous Duty,
- Travel, Straighteners,
Rubber Industry
Mash Tub .................................. 1.25 2.25 1.75
Unscramblers .............................. 2.00 3.00 2.50
Tire/Tube Press Opener (Peak
Lauter Tub ................................... 1.50 2.50 2.00
Coke Plants Pusher Ram
Torque) ...................................... 1.00
Scale Hopper, Frequent Peaks ... 1.75 2.75 2.25
Drive, ......................................... 2.50
*
*
Extruder, Mixing Mill, Refiner
Clay Working Industry
Coke Plants Pusher or Larry
or Sheeter (Five or More in
Brick Press, Briquette Machine,
Car Traction Drive, Feed
Line), Tuber, Strainer, Pelletizer,
Clay Working Machine,
Rolls-Blooming Mills, ManipWarming Mill (Three or More
Plug Mill ..................................... 1.75 2.75 2.25
ulators, Mill Tables Roughing
in Line) ....................................... 1.75
Dredges
Breakdown Mills, Runout,
Calender, Mixing Mill, Refiner
Conveyors ................................... 1.25 2.25 1.75
Reversing, Seamless Tube
or Sheeter (Three/Four in
Maneuvering Winch, Pumps
Mills Piercer, Sideguards ........... 3.00
*
*
Line), Warming Mill (One/Two
(Uniform Load), Utility Winch ..... 1.50 2.50 2.00
Cold Mills, Hot Mills, Merchant
in Line) ....................................... 2.00
Cable Reel, Screen Drive,
Stacker ...................................... 1.75 2.75 2.25
Mills, Rod Mills, Skelp Mills .............. Refer To Lovejoy
Cracker, Plasticator, Mixing
Cutter Head, Jig Drive ................. 2.00 3.00 2.50 Oil Industry
Mill, Refiner or Sheeter
Food Industry
Chiller .......................................... 1.25 2.25 1.75
(One/Two in line), Intensive
Bottling, Can Filling Machine ...... 1.00 2.00 1.50
Paraffin Filter Press .................... 1.50 2.50 2.00
or Banbury Mixer, Tire
Cereal Cooker ............................. 1.25 2.25 1.75
Oilwell Pumping (not over 150%
Building Machine, Washer ......... 2.50
Beet Slicer, Dough Mixer,
Peak Torque), Rotary Kiln ......... 2.00 3.00 2.50 Sewage Disposal Equipment
Meat Grinder ............................. 1.75 2.75 2.25 Paper Mills
Bar Screen, Chemical Feeders,
Lumber
Bleachers, Coaters, Stock
Collectors, Dewatering
Rolls, Non-Reversing,
Pumps, Centrifugal Constant
Screen, Grit Collector ................ 1.00
Sawdust Conveyor .................... 1.25 2.25 1.75
Speed ........................................ 1.00 2.00 2.50 Sugar Industry
Band Resaw, Sorting Table ........ 1.50 2.50 2.00
Converting Machine, Felt
Mill Stands, Turbine Driven with
Circular Resaw, Cut-off, Planer,
Stretcher, Stock Pumps,
all Helical or Herringbone
Slab Conveyor, Trimmer ........... 1.75 2.75 2.25
Centrifugal Frequent Speed
Gears ......................................... 1.50
Edger, Head Rig, Hog, Log
Changes Under Load ................ 1.25 2.25 1.75
Cane Carrier & Leveler, Electric
Haul, Rolls, Reversing ............... 2.00 3.00 2.50
Line Shaft, Reel, Rewinder,
Drive or Steam Engine Drive
Gang Saw (Reciprocating) ................. Refer To Lovejoy
Winder, Stock Chest, Washer,
with Helical Herringbone, or
Metal Rolling Mills1
Thickener ................................... 1.50 2.50 2.00
Spur Gears with any Prime
Soaking Pit Cover Drives - Lift .... 1.00 2.00 1.50

Reciprocating
Engines-4/5 Cylinder

Service Factors

Electric Motor w/
Standard Torque

Reciprocating
Engines-6 or more Cyl.

Reciprocating
Engines-4/5 Cylinder

Service Factors

Electric Motor w/
Standard Torque

Reciprocating
Engines-6 or more Cyl.

Reciprocating
Engines-4/5 Cylinder

Electric Motor w/
Standard Torque

Service Factors

1. For high peak load applications, please refer to selection process on page GD-4.
2. * Indicates that Lovejoy Application Engineering should be consulted with specific requirements.

Caution: Applications involving reciprocating engines and reciprocating driven devices are subject to critical rotational speeds which may damage the coupling and/or connected
equipment. Contact Lovejoy Application Engineering with specific requirements.

GD-5

Grid Type

Selection Data

GD

Bucket ......................................... 1.25 2.25 1.75


Mover ........................................ 1.75 2.75 2.25
Live Roll, Shaker,
Cane Knife & Crusher ................. 2.00 3.00 2.50
Reciprocating ............................ 3.00
*
*
Textile Industry
Cranes, Hoist1, 2
Batcher, Dyeing Machinery,
Slope ........................................... 1.50 2.50 2.00
Mangle, Napper, Soaper ........... 1.25 2.25 1.75
Main or Skip Hoist, Bridge,
Calender, Card Machine, Cloth
Travel, Trolley2 .............................................. 1.75 2.75 2.25
Finishing Machine, Dry Can,
Dynamometer ................................. 1.00 2.00 1.50
Loom, Spinner, Tenter Frame,
Elevators2
Winder ....................................... 1.50 2.50 2.00
Bucket, Centrifugal, Discharge,
Knitting Machine ................................... Refer To Lovejoy
Gravity Discharge ....................... 1.25 2.25 1.75
Freight or Passenger ..................... NOT APPROVED
Applications
Escalators .......................................... NOT APPROVED
Aerator ............................................ 2.00 3.00 2.50 Exciter, Generator .......................... 1.00 2.00 1.50
Agitators
Extruder, Plastic ............................. 1.50 2.50 2.00
Vertical/Horizontal Screw, ProFans
peller, Paddle ............................ 1.00 2.00 1.50
Centrifugal, Forced Draft Motor
Barge Haul Puller ........................... 1.50 2.50 2.00
Driven thru Fluid or Electric Slip
Blowers
Clutch ........................................ 1.00 2.00 1.50
Centrifugal ................................... 1.00 2.00 1.50
Induced Draft with Damper ConLobe, Vane .................................. 1.25 2.25 1.75
trol or Blade Cleaner ................. 1.25 2.25 1.75
Car Dumpers .................................. 2.50
*
*
Forced Draft-Across the Line
Car Pullers ...................................... 1.50 2.50 2.00
start, Gas Recirculating ............. 1.50 2.50 2.00
Clarifier, Classifier ......................... 1.00 2.00 1.50
Cooling Tower, Induced Draft
Compressors
without Controls ......................... 2.00 3.00 2.50
Centrifugal, Rotary, Screw .......... 1.00 2.00 1.50 Feeders
Rotary, Lobe or Vane .................. 1.25 2.25 1.75
Apron, Belt, Disc, Screw ............. 1.00 2.00 1.50
Reciprocating with Flywheel and
Reciprocating .............................. 2.50
*
*
Gear between Compressor and
Generators
Prime Mover 4 or More Cyl.
Even Load ................................... 1.00 2.00 1.50
Single/Double Acting ................. 1.75 2.75 2.25
Hoist or Railway Service ............. 1.50 2.50 2.00
Reciprocating with flywheel
Welder Load ................................ 2.00 3.00 2.50
and Gear between Compressor
Hammermill .................................... 1.75 2.75 2.25
and Prime Mover Cyl. Double
Laundrywasher or Tumbler ........... 2.00 3.00 2.50
Acting ........................................ 2.00 3.00 2.50 Line Shafts
Reciprocating with Flywheel and
Any Processing Machinery ......... 1.50 2.50 2.00
Gear between Compressor and
Machine Tools
Prime Mover 1/2 Cyl. Single/
Auxiliary, Traverse Drive ............. 1.00 2.00 1.50
Double Acting and 3 cyl.
Main Drive ................................... 1.50 2.50 2.00
Single Acting ............................. 3.00
*
*
Bending Roll, Notching Press,
Reciprocating Direct Connected,
Punch Press, Planer, Plate
Without Flywheels ............................... Refer To Lovejoy
Reversing .................................. 1.75 2.75 2.25
Conveyors2
Manlifts .............................................. NOT APPROVED
Apron, Assembly, Belt, Chain,
Flight, Screw .............................. 1.00 2.00 1.50

Notes:

Reciprocating
Engines-6 or more Cyl.

Service Factors
Reciprocating
Engines-4/5 Cylinder

Reciprocating
Engines-6 or more Cyl.

Reciprocating
Engines-4/5 Cylinder

Service Factors

Electric Motor w/
Standard Torque

Reciprocating
Engines-6 or more Cyl.

Reciprocating
Engines-4/5 Cylinder

Electric Motor w/
Standard Torque

Service Factors

Chart 1, cont.

Electric Motor w/
Standard Torque

Service FactorsIndustries and Applications

Metal Forming Machines


Slitters ......................................... 1.00 2.00 1.50
Wire Winder, Coilers, Uncoilers .. 1.50 2.50 2.00
Wire Drawing, Flattening ............. 1.75 2.75 2.25
Draw Bench Carriage, Main
Drive, Extruder, Forming
Machine, Forming Mills ............. 2.00 3.00 2.50
Mixers (see Agitators)
Muller .......................................... 1.50 2.50 2.00
Concrete ..................................... 1.75 2.75 2.25
Printing Press ................................. 1.50 2.50 2.00
Pug Mill ........................................... 1.75 2.75 2.25
Pulverizers
Roller ........................................... 1.50 2.50 2.00
Hammermill, Hog ........................ 1.75 2.75 2.25
Pumps
Centrifugal Constant Speed ........ 1.00 2.00 1.50
Centrifugal Frequent Speed
Changes under Load, Descaling,
w/ Accumulators, Gear, Rotary,
Vane .......................................... 1.25 2.25 1.75
Reciprocating, 3 or more
Cylinders ................................... 1.50 2.50 2.00
Reciprocating, 2 Cyl. Double
Acting ........................................ 1.75 2.75 2.25
Reciprocating, 2 Cyl. Single
Acting ........................................ 2.00 3.00 2.50
Reciprocating, 1 Cyl. Single/
Double Acting ............................ 3.00
*
*
Screens
Air Washing, Water ..................... 1.00 2.00 1.50
Rotary Coal, Sand ....................... 1.50 2.50 2.00
Grizzly ......................................... 2.00 3.00 2.50
Vibrating ...................................... 2.50
*
*
Ski Tows, Lifts ................................... NOT APPROVED
Steering Gear ................................. 1.00 2.00 1.50
Stoker .............................................. 1.00 2.00 1.50
Tumbling Barrel ............................. 1.75 2.75 2.25
Winch, Maneuvering
Dredge, Marine .......................... 1.50 2.50 2.00
Windlass ......................................... 1.50 2.50 2.00
Woodworking Machinery .............. 1.00 2.00 1.50
Work Lift Platforms ........................... NOT APPROVED

1. For high peak load applications, please refer to selection process on page GD-4.
2. If people are transported Lovejoy does not recommend and will not warranty the use of the coupling.
3. * Indicates that Lovejoy Application Engineering should be consulted with specific requirements.

Caution: Applications involving reciprocating engines and reciprocating driven devices are subject to critical rotational speeds which may damage the coupling and/or connected
equipment. Contact Lovejoy Application Engineering with specific requirements.

GD-6

Grid Type
General Service Factors

Selection Data
Chart 2

Typical Applications for Electric Motor


or Turbine Driven Equipment

Typical
Service Factor

Constant Torque such as Centrifugal


Pumps, Blowers, and Compressors.

1.0

Continuous Duty with some torque


variations including Printing Presses,
Extruders, Forced Draft Fans.

1.5

Light shock loads from Briquetting


Machine, Rubber Calender, or
Crane and Hoist

2.0

Moderate shock loading as expected


from a Car Dumper, Reciprocating
Feeder, or Vibrating Screen.

2.5

Heavy Shock load with some


negative torques from Crushers,
Manipulators and Braking Drum.

3.0

Applications like Reciprocating


Compressors with frequent torque
reversals which do not necessarily
cause reverse rotations.

Consult
Lovejoy
Application
Engineering

Torque Ratings Taper-Lock Bushing Hubs Chart 1


Maximum Bore1
Taper-Lock
Bushing
Size
Bushing
inch

Maximum Torque Rated Torque


Bushing
Coupling
in-lbs
in-lbs

1030

1108

1.125

1300.0

1200.0

1040

1108

1.125

1300.0

2000.0

1050

1215

1.250

3550.0

3500.0

1060

1615

1.625

4300.0

5500.0

1070

2012

2.000

7150.0

8000.0

1080

2525

2.500

11300.0

16500.0

1090

3030

3.000

24000.0

30000.0

1100

3030

3.000

24000.0

50500.0

1110

3535

3.500

44800.0

75000.0

1120

4040

4.000

77300.0

110000.0

Note:

1. The maximum bore is with a standard keyway.

Torque and Horsepower Ratings

Chart 3
Horizontal
Max RPM
x1000
4.500
4.500
4.500
4.500
4.350
4.125
3.600
3.600
2.440
2.250
2.025
1.800
1.650
1.500
1.350
1.225
1.100
.....a
.....a
.....a
.....a
.....a
.....a
.....a
.....a

Vertical
Max RPM
x1000
6.000
6.000
6.000
6.000
6.000
5.500
4.750
4.000
3.250
3.000
2.700
2.400
2.200
.....a
.....a
.....a
.....a
2.400
1.450
1.300
1.200
1.100
0.980
0.860
0.740

GD

Size
1020
1030
1040
1050
1060
1070
1080
1090
1100
1110
1120
1130
1140
1150
1160
1170
1180
G5430
G5431
G5433
G5435
G5437
G5439
G5441
G5443
Notes:

Basic HP Ratings
@ Varying RPM
Torque Ratings
Maximum Bore
100
1200
1800
3600
in-lbs
Nm
inch
mm
0.67
8.04
12.06
24.12
422
48
1.125
27
1.88
22.56
33.84
67.68
1200
136
1.375
35
3.22
38.64
57.96
115.92
2000
226
1.625
44
5.49
65.88
98.82
197.64
3500
395
1.875
51
8.71
104.52
156.78
313.56
5500
621
2.125
57
12.73
152.76
229.14
458.28
8000
904
2.500
68
26.13
313.56
470.34
940.68
16500
1864
3.000
83
47.57
570.84
856.26
1712.52
30000
3390
3.500
95
80
960.00 1440.00
.....aa
50500
5706
4.000
108
119
1428.00 2142.00
.....aa
75000
8474
4.500
117
175.5
2106.00 3159.00
.....aa
110000
12428
5.000
137
253.3
3039.60 4559.40
.....aa
160000
18078
6.000
165
364.5
4374.00 6561.00
.....aa
230000
25987
7.000
184
509.58
6114.96
.....aa
.....aa
320000
36300
8.000
200
724.14
8689.68
.....aa
.....aa
457000
51600
9.000
228
952.11 11425.32
.....aa
.....aa
600000
67800
10.000
254
1314.18
.....aa
.....aa
.....aa
830000
93600
11.000
280
509.58
6114.96 9172.44
.....aa
320000
36300
8.250
210
724.14
8689.68
.....aa
.....aa
457000
51600
7.500
190
952.11 11425.32
.....aa
.....aa
600000
67800
8.438
215
1314.18 15770.16
.....aa
.....aa
830000
93600
9.250
235
1756.71
.....aa
.....aa
.....aa
1100000
125000
10.438
265
2386.98
.....aa
.....aa
.....aa
1500000
170000
11.563
295
3178.17
.....aa
.....aa
.....aa
2000000
226000
12.750
325
4291.2
.....aa
.....aa
.....aa
2700000
306000
16.313
415
1. The maximum bore for the G54 series includes a shallow keyway.
2. Sizes 1020 through 1140 are tapered grid styles; sizes 1150 through G5443 are straight grid style.

GD-7

Grid Type

Item Selection

1000 Series Tapered Grid Hub Item (UPC) NumbersInch

Chart 1

When referencing the Lovejoy Item (UPC) number, include 697904 as a prefix to the number shown in the table below.
Bore

Keyway

SOLID
1

/2
5
/8
3
/4
7
/8
15
/16

GD

1
11/8
13/16
11/4
13/8
17/16
11/2
15/8
111/16
13/4
113/16
17/8
115/16

1020

1030

1040

1050

1060

1070

1080

1090

1100

1110

1120

1130

1140

05231

05232

05233

05234

05235

05236

05237

05238

05239

05240

05241

05242

05243

05458
05459
05460
05461
06100

.....
05464
05465
05466
06101

.....
.....
06140
05471
06103

.....
.....
.....
06141
06106

.....
.....
.....
06142
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

.....
.....
.....
.....
.....

05462
05463
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

05467
05468
06102
05469
05470
.....
.....
.....
.....
.....
.....
.....
.....

05472
05473
06104
05474
05475
06105
05476
05477
.....
.....
.....
.....
.....

06107
05478
06108
05479
05480
06109
05481
05482
06110
05483
06111
05484
.....

06112
06113
06114
06115
05485
06116
05486
05487
06117
05488
06118
05489
06143

.....
06144
.....
06145
06119
06120
06121
05492
06122
05493
06123
05494
06146

.....
07364
.....
06148
06149
.....
.....
06150
.....
06124
06125
06126
06151

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
06154
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

/8 x 1/16
3
/16 x 3/32
3
/16 x 3/32
3
/16 x 3/32
1
/4 x 1/8
/4 x 1/8
/4 x 1/8
1
/4 x 1/8
1
/4 x 1/8
5
/16 x 5/32
3
/8 x 3/16
3
/8 x 3/16
3
/8 x 3/16
3
/8 x 3/16
3
/8 x 3/16
1
/2 x 1/4
1
/2 x 1/4
1
/2 x 1/4
1

2
21/8
23/16
21/4
23/8
21/2
25/8
23/4
27/8
215/16

/2 x 1/4
/2 x 1/4
1
/2 x 1/4
1
/2 x 1/4
5
/8 x 5/16
5
/8 x 5/16
5
/8 x 5/16
5
/8 x 5/16
3
/4 x 3/8
3
/4 x 3/8

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

05490
05491
.....
.....
.....
.....
.....
.....
.....
.....

05495
05496
06147
05497
05498
05499
.....
.....
.....
.....

05500
05501
06152
05502
05503
05504
05505
05506
05507
06153

06155
06127
06156
06128
06129
05509
05510
05511
05512
06157

.....
.....
.....
.....
.....
05519
05520
05521
05522
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

3
31/8
31/4
33/8
37/16
31/2
35/8
33/4
37/8

/4 x 3/8
/4 x 3/8
3
/4 x 3/8
7
/8 x 7/16
7
/8 x 7/16
7
/8 x 7/16
7
/8 x 7/16
7
/8 x 7/16
1" x 1/2

.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....

05508
.....
.....
.....
.....
.....
.....
.....
.....

05513
05514
05515
05516
06158
05517
.....
.....
.....

05523
05524
05525
05526
.....
05527
05528
05529
05530

05532
05533
05534
05535
.....
05536
05537
05538
05539

05542
05543
05544
05545
.....
05546
05547
05548
05549

.....
.....
.....
.....
.....
05553
05554
05555
05556

.....
.....
.....
.....
.....
.....
.....
.....
05562

4
41/2
5
51/2

1" x 1/2
1" x 1/2
11/4 x 5/8
11/4 x 5/8

.....
.....
.....
.....

.....
.....
.....
.....

.....
.....
.....
.....

.....
.....
.....
.....

.....
.....
.....
.....

.....
.....
.....
.....

.....
.....
.....
.....

.....
.....
.....
.....

05531
.....
.....
.....

05540
05541
.....
.....

05550
05551
05552
.....

05557
05558
05559
05560

05563
05564
05565
05566

6
61/2
7

11/2 x 3/4
11/2 x 3/4
11/2 x 3/4

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

.....
.....
.....

05561
.....
.....

05567
05568
05569

Notes:

GD-8

1. 1020-1090 hubs are provided with a Clearance Fit bore and 2 Set Screws at 90.
2. 1100-1140 hubs are provided with an Interference Fit bore and no Set Screws.
3. A complete grid coupling consists of two hubs and one Cover/Grid Assembly.

Grid Type

Item Selection

G2000 Series Tapered Grid Hub Item (UPC) NumbersMetric

Chart 2

When referencing the Lovejoy Item (UPC) number, include 697904 as a prefix to the number shown in the table below.
Bore

Keyway

1020

1030

1040

1050

1060

1070

1080

1090

14
15
16
19
20
22
24
25
28
30
32
35
38
42
48
55
60
70
80
85
95

5 x 2.3
5 x 2.3
5 x 2.3
6 x 2.8
6 x 2.8
6 x 2.8
8 x 3.3
8 x 3.3
8 x 3.3
8 x 3.3
10 x 3.3
10 x 3.3
10 x 3.3
12 x 3.3
14 x 3.8
16 x 4.3
18 x 4.4
20 x 4.9
22 x 5.4
22 x 5.4
25 x 5.4

05780
05781
05782
05783
05784
05785
05786
05787
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
05788
05789
05790
05791
05792
05793
05794
05795
05796
.....
......
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
05797
05798
05799
05800
05801
05802
05803
05804
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
05805
05806
05807
05808
05809
05810
05811
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
05812
05813
05814
05815
05816
.....
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
05817
05818
05819
05820
05821
05822
.....
.....
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
05823
05824
05825
05826
05827
05828
05829
.....
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
05830
05831
05832
05833
05834
05835
05836
05837

Notes:

1. 1020-1090 hubs are provided with a Clearance Fit bore and 2 Set Screws at 90.
2. A complete grid coupling consists of two hubs and one Cover/Grid Assembly.

GD

1000 Series Taper-Lock Grid Hub Item (UPC) Numbers

Chart 3

When referencing the Lovejoy Item (UPC) Number, include 697904 as a prefix to the number shown in the table below.
Taper-Lock
Hub

1030

1040

1050

1060

1070

1080

1090

1100

1110

1120

UNC Thread

06841

06842

06843

06844

06845

06846

06847

06848

06849

06850

BSW Thread

06851

06852

06853

06854

06855

06856

06857

06858

06859

06860

GD-9

Grid Type

Item Selection

Item (UPC) Numbers1000 Series Tapered Grid Component Parts

Chart 3

When referencing the Lovejoy Item (UPC) number, include 697904 as a prefix to the number shown in the table below. A complete Grid Coupling consists of two
hubs and one Cover/Grid Assembly.
Sizes

1020

1030

1040

1050

1060

1070

1080

1090

1100

1110

1120

1130

1140

Grid Only
Horizontal Design:
Cover/Grid Assembly-Metric
Cover/Grid Assembly-Inch
Cover Set - Metric
Cover Set - Inch
Seal Kit
Cover Hardware - Metric
Cover Hardware - Inch
Vertical Design:
Cover/Grid Assembly-Metric
Cover/Grid Assembly-Inch
Cover Set - Metric
Cover Set - Inch
Seal Kit
Cover Hardware - Metric
Cover Hardware - Inch

05244

05245

05246

05247

05248

05249

05250

05251

05252

05253

05254

05255

05256

05366
05349
05290
05273
05176
05210
05433

05367
05350
05291
05274
05177
05210
05433

05368
05351
05292
05275
05178
05210
05433

05369
05352
05293
05276
05179
05211
05434

05370
05353
05294
05277
05180
05211
05434

05371
05354
05295
05278
05181
05212
05435

05372
05355
05296
05279
05182
05212
05435

05373
05356
05297
05280
05183
05212
05435

05374
05357
05298
05281
05184
05213
05436

05375
05358
05299
05282
05185
05213
05436

05376
05359
05300
05283
05186
05214
05437

05377
05360
05301
05284
05187
05214
05437

05378
05361
05302
05285
05188
05214
05437

05400
05383
05328
05307
05189
05215
05442

05401
05384
05329
05308
05190
05216
05443

05402
05385
05330
05309
05191
05216
05443

05403
05386
05331
05310
05192
05217
05444

05404
05387
05332
05311
05193
05217
05444

05405
05388
05333
05312
05194
05217
05444

05406
05389
05334
05313
05195
05218
05445

05407
05390
05335
05314
05196
05218
05445

05408
05391
05336
05315
05197
05219
05446

05409
05392
05337
05316
05198
05219
05446

05410
05393
05338
05317
05199
05220
05447

05411
05394
05339
05318
05200
05221
05448

05412
05395
05340
05319
05201
05222
05449

Notes:

1.
2.
3.
4.
5.

Cover/Grid Assembly includes ALL components of the coupling, other than the hubs. The terms metric and inch refer to hardware.
Cover Set includes all of the above items except the Grid spring.
Seal Kit contains rubber seals, gasket(s) and lube plugs.
Cover Hardware includes the fasteners that hold the cover together.
Grease packets are included with all Cover Sets and Cover/Grid assemblies thru size G20%

GD

Item (UPC) NumbersStraight Grid Component Parts

Chart 4

When referencing the Lovejoy Item (UPC) number, include 697904 as a prefix to the number shown in the table below. A complete Grid Coupling consists of
two hubs and one Cover/Grid Assembly.
Sizes

1150

1160

1170

1180

Horizontal Design:
Hub 73mm RSB
Hub 100mm RSB
Hub Free 100mm RSB
Hub Fixed 100mm RSB
Hub 125mm RSB
Hub Free 125mm RSB
Hub Fixed 125mm RSB
Hub Free 150mm RSB
Hub Fixed 150mm RSB
Hub Free 175mm RSB
Hub Fixed 175mm RSB
Grid Only
Cover/Grid Assembly-Metric
Cover/Grid Assembly-Inch
Cover Set - Metric
Cover Set - Inch
Seal Kit
Cover Hardware - Metric
Cover Hardware - Inch

Notes:

GD-10

1.
2.
3.
4.
5.

G5430

G5431

G5433

G5435

G5437

G5439

G5441

G5443

.....
.....
05267
06765
.....
.....
.....
.....
.....
.....
.....
05259
05415
.....
05343
.....
05204
05225
.....

.....
.....
.....
.....
.....
05268
06766
.....
.....
.....
.....
05260
05416
.....
05344
.....
05205
05226
.....

.....
.....
.....
.....
.....
05269
06767
.....
.....
.....
.....
05261
05417
.....
05345
.....
05206
05227
.....

.....
.....
.....
.....
.....
.....
.....
05270
06768
.....
.....
05262
05418
.....
05346
.....
05207
05228
.....

.....
.....
.....
.....
.....
.....
.....
05271
06769
.....
.....
05263
05419
.....
05347
.....
05208
05229
.....

.....
.....
.....
.....
.....
.....
.....
.....
.....
05272
06770
05264
05420
.....
05348
.....
05209
05230
.....

Vertical Design:
05587
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
05257
05379
05362
05303
05286
05425
05429
05438

.....
05589
.....
.....
.....
.....
.....
.....
.....
.....
.....
05258
05380
05363
05304
05287
05426
05429
05438

.....
05591
.....
.....
.....
.....
.....
.....
.....
.....
.....
05259
05381
05364
05305
05288
05427
05430
05439

.....
.....
.....
.....
05593
.....
.....
.....
.....
.....
.....
05260
05382
05365
05306
05289
05428
05430
05439

05265
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
05257
05413
....
05341
.....
05202
05223
.....

.....
.....
05266
06764
.....
.....
.....
.....
.....
.....
.....
05258
05414
.....
05342
.....
05203
05224
.....

Cover/Grid Assembly includes ALL components of the coupling, other than the hubs. The terms metric and inch refer to hardware.
Cover Set includes all of the above items except the Grid spring.
Seal Kit contains rubber seals, gasket(s) and lube plugs.
Cover Hardware includes the fasteners that hold the cover together.
Grease packets are included with all Cover Sets and Cover/Grid assemblies thru size G2090.

Grid Type

Performance Data

Interchange Chart
Lovejoy
Size
1020
1030
1040
1050
1060
1070
1080
1090
1100
1110
1120
1130
1140
1150
1160
1170
1180
G5430
G5431
G5433

Note:

Falk
Steelflex
1020T10
1030T10
1040T10
1050T10
1060T10
1070T10
1080T10
1090T10
1100T10
1110T10
1120T10
1130T10
1140T10
1150T10
1160T10
1170T10
1180T10
.....
.....
.....

Horizontal
Split Cover
Morse/Browning
Dodge
Grid-Flex
Grid-Lign
GF2020H
1020T10
GF2030H
1030T10
GF2040H
1040T10
GF2050H
1050T10
GF2060H
1060T10
GF2070H
1070T10
GF2080H
1080T10
GF2090H
1090T10
GF2100H
1100T10
GF2110H
1110T10
GF2120H
1120T10
GF2130H
1130T10
GF2140H
1140T10
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

Kop-Flex
Kop-Grid
1020H
1030H
1040H
1050H
1060H
1070H
1080H
1090H
1100H
1110H
1120H
1130H
1140H
.....
.....
.....
.....
.....
.....
.....

Falk
Steelflex
1020T20
1030T20
1040T20
1050T20
1060T20
1070T20
1080T20
1090T20
1100T20
1110T20
1120T20
1130T20
1140T20
.....
.....
.....
.....
1150T20
1160T20
1170T20

Vertical
Split Cover
Morse/Browning
Dodge
Grid-Flex
Grid-Lign
GF2020V
1020T20
GF2030V
1030T20
GF2040V
1040T20
GF2050V
1050T20
GF2060V
1060T20
GF2070V
1070T20
GF2080V
1080T20
GF2090V
1090T20
GF2100V
1100T20
GF2110V
1110T20
GF2120V
1120T20
GF2130V
1130T20
GF2140V
1140T20
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

Kop-Flex
Kop-Grid
1020V
1030V
1040V
1050V
1060V
1070V
1080V
1090V
1100V
1110V
1120V
1130V
1140V
.....
.....
.....
.....
.....
.....
.....

1020 to 1140 interchanges with Falk. 1150 and above are not direct interchanges with Falk.

Size
1020
1030
1040
1050
1060
1070
1080
1090
1100
1110
1120
1130
1140
1150
1160
1170
1180
G5430
G5431
G5433
G5435
G5437
G5439
G5441
G5443

Note:

100
0.67
1.88
3.22
5.49
8.71
12.73
26.13
47.57
80.00
119.00
175.50
253.30
364.50
509.58
724.14
952.11
1314.18
509.58
724.14
952.11
1314.18
1756.71
2386.98
3178.17
4291.2

Basic HP Ratings
@ Varying RPM
1200
1800
8.04
12.06
22.56
33.84
38.64
57.96
65.88
98.82
104.52
156.78
152.76
229.14
313.56
470.34
570.84
856.26
960.00 1440.00
1428.00 2142.00
2106.00 3159.00
3039.60 4559.40
4374.00 6561.00
6114.96
.....aa
8689.68
.....aa
11425.32
.....aa
.....aa
.....aa
6114.96 9172.44
8689.68
.....aa
11425.32
.....aa
15770.16
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa

3600
24.12
67.68
115.92
197.64
313.56
458.28
940.68
1712.52
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa
.....aa

Torque Ratings
in-lbs
Nm
422
48
1200
136
2000
226
3500
395
5500
621
8000
904
16500
1864
30000
3390
50500
5706
75000
8474
110000
12428
160000
18078
230000
25987
320000
36300
457000
51600
600000
67800
830000
93600
320000
36300
457000
51600
600000
67800
830000
93600
1100000
125000
1500000
170000
2000000
226000
2700000
306000

Maximum Bore
inch
mm
1.125
27
1.375
35
1.625
44
1.875
51
2.125
57
2.500
68
3.000
83
3.500
95
4.000
108
4.500
117
5.000
137
6.000
165
7.000
184
8.000
200
9.000
228
10.000
254
11.000
280
8.250
210
7.500
190
8.438
215
9.250
235
10.438
265
11.563
295
12.750
325
16.313
415

Horizontal
Max RPM
x1000
4.500
4.500
4.500
4.500
4.350
4.125
3.600
3.600
2.440
2.250
2.025
1.800
1.650
1.500
1.350
1.225
1.100
.....a
.....a
.....a
.....a
.....a
.....a
.....a
.....a

GD

Torque and Horsepower Ratings


Vertical
Max RPM
x1000
6.000
6.000
6.000
6.000
6.000
5.500
4.750
4.000
3.250
3.000
2.700
2.400
2.200
.....a
.....a
.....a
.....a
2.400
1.450
1.300
1.200
1.100
0.980
0.860
0.740

The maximum bore for 5430 to G5443 includes a shallow keyway.

GD-11

Grid Type

Performance Data

Misalignment Capacity

GD

Coupling
Size
1020
1030
1040
1050
1060
1070
1080
1090
1100
1110
1120
1130
1140
1150
1160
1170
1180
G5430
G5431
G5433
G5435
G5437
G5439
G5441
G5443

Note:

Max. Installation
Misalignment
Parallel
Angular
P
X-Y
0.006
0.006
0.006
0.008
0.008
0.008
0.008
0.008
0.010
0.010
0.011
0.011
0.011
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.010
0.014
0.014

0.003
0.003
0.003
0.004
0.005
0.005
0.006
0.007
0.008
0.009
0.010
0.012
0.013
0.014
0.014
0.014
0.014
0.014
0.014
0.014
0.014
0.014
0.014
0.020
0.020

Operating
Misalignment
Parallel
Angular
P
X-Y
0.012
0.012
0.012
0.016
0.016
0.016
0.016
0.016
0.020
0.020
0.022
0.022
0.022
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

0.010
0.012
0.013
0.016
0.018
0.020
0.024
0.028
0.033
0.036
0.040
0.047
0.053
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.125
0.188
0.188
0.250
0.250
0.250
0.248
0.248
0.248
0.248
0.098
0.118
0.118
0.118
0.118
0.118
0.236
0.236

Misalignment ratings pertain to both standard and spacer grid couplings.

Misalignment Capacity:
Parallel: The movement of the grid in the hub
grooves accommodates parallel misalignment
and still permits full functioning of the gridgroove action in damping out shock and
vibration.
Angular: Under angular misalignment, the
grid-groove design permits a rocking and
sliding action of the grid and hubs without any
loss of power through the resilient grid.
Axial: End float is permitted for both driving
and driven members because the grid slides
freely in the grooves.

GD-12

Normal
Gap
10 %
G

ANGULAR MISALIGNMENT

PARALLEL MISALIGNMENT

NORMAL GAP

Grid Type

Dimensional Data

Horizontal Style Grid Couplings


Grid couplings with horizontally split covers are ideal for limited space
applications. The cover design allows for easy access to the grid. In
addition, this cover style is well-suited for reversing service applications.

1150

1020-1140

1160-1180

Size

Min.

Max.

Outer
Dia.
OD

1020
1030
1040
1050
1060
1070
1080
1090
1100
1110
1120
1130
1140
1150
1160
1170
1180

0.500
0.500
0.500
0.500
0.750
0.750
1.000
1.000
1.625
1.625
2.375
2.625
2.625
3.000
4.188
4.188
5.125

1.125
1.375
1.625
1.875
2.125
2.500
3.000
3.500
4.000
4.500
5.000
6.000
7.000
8.000
9.000
10.000
11.000

4.00
4.38
4.63
5.44
5.94
6.38
7.63
8.38
9.88
10.63
12.13
13.63
15.13
17.91
20.47
23.03
25.00

Bore

Notes:

Overall
Length
OAL
3.88
3.88
4.13
4.88
5.13
6.13
7.13
7.88
9.69
10.19
12.00
13.00
14.75
14.65
15.85
17.25
19.07

Gap
G

Length
Thru
Bore
LTB

Hub
Dia.
HD

0.13
0.13
0.13
0.13
0.13
0.13
0.13
0.13
0.19
0.19
0.25
0.25
0.25
0.25
0.25
0.25
0.25

1.88
1.88
2.00
2.38
2.50
3.00
3.50
3.88
4.75
5.00
5.88
6.38
7.25
7.20
7.80
8.50
9.41

1.56
1.94
2.25
2.63
3.00
3.44
4.13
4.88
5.59
6.31
7.06
8.56
10.00
11.54
11.97
13.98
15.47

Set
Screw
Length Location Size
L
SL
T
2.63
2.69
2.75
3.13
3.63
3.75
4.56
4.81
6.13
6.36
7.55
7.69
7.92
8.42
10.43
11.85
12.24

0.50
0.31
0.44
0.62
0.44
0.88
0.94
1.03
.....
.....
.....
.....
.....
.....
.....
.....
.....

#8-32
#8-32
#10-24
#10-24
#10-24
1
/4 -20
1
/4 -20
5
/16 -18
.....
.....
.....
.....
.....
.....
.....
.....
.....

Weight
lbs
Solid

Moment
of Inertia
WR2 lb-in2
Solid

4.2
5.7
7.4
12.0
16.0
23.0
39.0
56.0
93.0
120.0
179.0
266.0
392.0
523.0
720.0
1022.5
1341.7

4.830
7.610
11.190
24.850
40.660
63.180
154.000
269.000
609.000
923.000
1755.000
3378.000
6306.000
.....A
.....A
.....A
.....A

GD

Dimensional DataInch

1. Maximum bores are less than shown above when an Interference Fit and Set Screw are required, refer to Lovejoy Application Engineering. Sizes 1020 through 1090 are Clearance Fit with 2 Set Screws at 90. Sizes 1100 and larger are an Interference Fit with no Set Screw.
2. Based on application data, larger bores may be possible - contact Lovejoy Application Engineering.
3. See pages GD-11 & GD-12 for Performance Data.

GD-13

Grid Type

Dimensional Data

Vertical Style Grid Couplings


Vertically split cover design grid couplings are ideal for applications with
higher operating speeds. Sizes G1020-1140 and G5430 are stamped steel,
sizes G5431 and above are cast iron. This cover style offers superior
protection and supreme performance.

1050V

1020-1140

1060V-1220V

GD

Dimensional DataInch

Size
1020
1030
1040
1050
1060
1070
1080
1090
1100
1110
1120
1130
1140
G5430
G5431
G5433
G5435
G5437
G5439
G5441
G5443

Notes:

GD-14

Bore
Min.
Max.
0.500 1.125
0.500 1.375
0.500 1.625
0.500 1.875
0.750 2.125
0.750 2.500
1.000 3.000
1.000 3.500
1.625 4.000
1.625 4.500
2.375 5.000
2.625 6.000
2.625 7.000
3.000 8.250
4.188 7.438
4.188 8.438
5.125 9.250
5.125 10.375
6.125 11.500
6.125 12.688
7.000 16.313

Outer Overall
Dia. Length Gap
OD
OAL
G
4.38
3.88 0.13
4.75
3.88 0.13
5.06
4.13 0.13
5.81
4.88 0.13
6.38
5.13 0.13
6.81
6.13 0.13
7.88
7.13 0.13
9.13
7.88 0.13
10.50
9.69 0.19
11.25 10.19 0.19
12.56 12.00 0.25
14.88 13.00 0.25
16.38 14.75 0.25
16.73 13.88 0.10
20.87 15.87 0.12
23.23 17.05 0.12
25.20 19.02 0.12
26.77 20.59 0.12
30.71 22.17 0.12
34.25 24.25 0.24
39.76 25.83 0.24

Length
Thru
Bore
LTB
1.88
1.88
2.00
2.38
2.50
3.00
3.50
3.88
4.75
5.00
5.88
6.38
7.50
6.89
7.87
8.46
9.45
10.24
11.02
12.01
12.80

Set
Hub Flange
Flange
Screw
Dia. Dia. Length Length Max Location Size
HD
FD
L
FL
R
SL
T
1.56 2.50 0.96
0.38 1.88
0.50
#8-32
1.94 2.88 1.00
0.38 1.88
0.31
#8-32
2.25 3.25 1.03
0.38 2.00
0.44
#10-24
2.63 3.88 1.24
0.47 2.38
0.62
#10-24
3.00 4.38 1.27
0.50 2.50
0.44
#10-24
1
3.44 4.88 1.33
0.50 2.63
0.88
/4 -20
1
4.13 5.88 1.74
0.50 3.50
0.94
/4 -20
5
4.88 6.63 1.86
0.50 3.75
1.03
/16 -18
5.59 7.75 2.38
0.63 4.75
.....
.....
6.31 8.50 2.50
0.63 4.88
.....
.....
7.06 9.63 2.94
0.68 5.63
.....
.....
8.56 11.13 3.00
0.82 5.75
.....
.....
10.00 12.63 3.13
0.82 6.13
.....
.....
11.54 .....
.....
.....
5.91
.....
.....
10.43 .....
.....
.....
7.72
.....
.....
11.81 .....
.....
.....
8.58
.....
.....
12.99 .....
.....
.....
8.98
.....
.....
14.57 .....
.....
.....
8.98
.....
.....
16.34 .....
.....
.....
9.76
.....
.....
17.91 .....
.....
..... 11.89
.....
.....
22.83 .....
.....
..... 11.89
.....
.....

Weight
lbs
Solid
4.3
5.7
7.4
12.0
16.0
23.0
39.0
56.0
93.0
120.0
180.0
270.0
397.0
511.6
632.8
848.9
1124.6
1459.7
1997.7
2826.8
4343.9

Moment
of Inertia
WR2 lb.in2
Solid
5.320
7.990
11.990
25.760
41.160
61.680
148.000
272.000
608.000
930.000
1611.000
3568.000
6431.000
9740.568
20472.282
34587.561
52838.309
77822.012
138486.953
259509.239
537064.161

1. Maximum bores are less than shown above when an Interference Fit and Set Screw are required - refer to Lovejoy Application Engineering. Sizes
1020 through 1090 are Clearance Fit with 2 Set Screws at 90. Sizes 1100 and larger are Interference Fit with no Set Screw.
2. Based on application data, larger bores may be possible - contact Lovejoy Application Engineering.
3. See pages GD-11 & GD-12 for Performance Data.

Grid Type

Dimensional Data

Spacer Style Grid Couplings


The full spacer design grid coupling is ideal for pump applications. The
drop-out section allows for pump servicing.
G1

Spacer Dimensional DataInch


Bore
Max.

LTB

OD

FD

HD

1020

1.375

1.38

3.38

0.19

2.06

1030

1.625

1.62

4.38

3.69

0.19

2.34

1040

2.125

2.12

4.62

4.44

0.19

3.09

1050

2.375

2.38

5.44

4.94

0.19

3.44

1060

2.875

2.88

5.94

5.69

0.19

4.06

1070

3.125

3.12

6.38

0.19

4.31

1080
1090

3.5
4

3.5
4

7.62
8.38

7
8.25

0.19
0.19

4.81
5.62

Note:

OAL

BSE

6.26
7.76
6.74
8.24
10.49
7.74
9.24
11.49
9.76
12.01
10.76
13.01
11.24
13.49
14.25
15.25

3.50
5.00
3.50
5.00
7.25
3.50
5.00
7.25
5.00
7.25
5.00
7.25
5.00
7.25
7.25
7.25

1.63
2.38
1.63
2.38
3.50
1.63
2.38
3.50
2.38
3.50
2.34
3.47
2.34
3.47
3.47
3.47

SL

G1

#8-32

0.30

0.03

#8-32

0.38

0.03

#10-24

1.04

0.03

#10-24

0.78

0.03

#10-24

1.18

0.06

1.28

0.06

1.54
1.76

0.06
0.06

/4 -20

/4 -20
/16 -18

GD

Coupling
Size

Sizes 1020 through 1090 are Clearance Fit with 2 Set Screws at 90.

Spacer Grid Couplings Ratings

Size
1020
1030
1040
1050
1060
1070
1080
1090

Basic HP Ratings
@ Varying RPM
100
1200
1800
0.67
1.88
3.22
5.49
8.71
12.73
26.13
47.57

8.04
22.56
38.64
65.88
104.52
152.76
313.56
570.84

12.06
33.84
57.96
98.82
156.78
229.14
470.34
856.26

Torque Ratings
in-lbs
Nm

Maximum Bore
inch
mm

422
1200
2000
3500
5500
8000
16500
30000

1.375
1.625
2.125
2.375
2.875
3.125
3.500
4.000

48
136
226
395
621
904
1864
3390

35
41
54
60
73
79
89
102

Max RPM
x1000
3.600
3.600
3.600
3.600
3.600
3.600
3.600
3.600

GD-15

Grid Type

Dimensional Data

Spacer Style Grid Couplings


Full Spacer Coupling BSEInch

1020
Hubs S
1030
Hubs S
1040
Hubs S
1050
Hubs S
1060
Hubs S
1070
Hubs S
1080
Hubs S
1090
Hubs S

Note:

3.500

3.938

4.250

4.375

4.688

5.000

5.219

BSE
5.375

5.656

5.813

5.969

6.125

6.938

7.094

7.250

1.625
1.625
1.625
1.625
1.625
1.625
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

1.625
2.062
1.625
2.062
1.625
2.062
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

1.625
2.375
1.625
2.375
1.625
2.375
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

2.062
2.062
2.062
2.062
2.062
2.062
2.062
2.062
.....
.....
.....
.....
.....
.....
.....
.....

2.062
2.375
2.062
2.375
2.062
2.375
2.062
2.375
.....
.....
.....
.....
.....
.....
.....
.....

2.375
2.375
2.375
2.375
2.375
2.375
2.375
2.375
2.344
2.344
2.344
2.344
.....
.....
.....
.....

.....
......
.....
.....
1.625
3.344
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
1.625
3.500
1.625
3.500
.....
.....
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
2.062
3.344
2.062
3.344
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
2.062
3.500
2.062
3.500
2.062
3.500
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
2.375
3.344
2.375
3.344
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
2.375
3.500
2.375
3.500
2.375
3.500
2.344
3.469
2.344
3.469
.....
.....
.....
.....

.....
.....
.....
.....
3.344
3.344
3.344
3.344
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
.....
.....
3.344
3.500
3.344
3.500
.....
.....
.....
.....
.....
.....
.....
.....

.....
.....
3.500
3.500
3.500
3.500
3.500
3.500
3.469
3.469
3.469
3.469
3.469
3.469
3.469
3.469

To achieve the Between Shaft End dimension shown, use the two spacer hubs with the specified S lengths. To obtain the Between Shaft End
dimension, use the two spacer hub lengths and the G and two G1 Dimensions. Assembly includes 2 spacer hubs, 2 shaft hubs, and cover/grid
assembly.

GD

Half Spacer Coupling BSEInch

1020
Hub S
1030
Hub S
1040
Hub S
1050
Hub S
1060
Hub S
1070
Hub S
1080
Hub S
1090
Hub S

Note:

GD-16

1.781

2.219

BSE
2.531

3.500

3.656

1.625

2.062

2.375

.....

.....

1.625

2.062

2.375

.....

3.500

1.625

2.062

2.375

3.344

3.500

.....

.....

2.375

3.344

3.500

.....

.....

2.344

.....

3.469

.....

.....

2.344

.....

3.469

.....

.....

.....

.....

3.469

.....

.....

.....

.....

3.469

To achieve the Between Shaft End dimension shown, use the


spacer hub with the specified S length. Assembly includes
spacer hub, shaft hub, standard hub and cover/grid assembly.

Grid Type

Technical Data

Lovejoy Coupling Grease


Lovejoy Coupling Grease was designed to resist centrifugal
separation, thereby keeping the oil portion of the grease in the
working areas of the coupling. When using the Lovejoy Coupling
Grease, lubrication intervals may be extended. A coupling exposed
to extreme temperatures, excessive moisture, frequent reversals or
grease leakage may require more frequent lubrication.
The benefits of this product include:
Highest pressure and wear protection available.
Built-in rust and corrosion inhibitors.
Increased coupling life.
Reduced maintenance costs.
Reduced downtime.
Superior lubrication.
Lovejoy Coupling Grease has the U.S. Department of Agriculture
Food Safety & Inspection Service approval for use in applications
where there is no possibility of contact with edible products.

Specifications

If an alternative grease is used it should meet the minimum


specifications listed below. Table 4 is a list of grease products that
meet the general specifications but should not be considered
exclusive recommendations.

Table 4

Ambient Temperature Range:


Manufacturer

0 F to 150 F
(-18 C to 66 C)

-30 F to 100 F1
(-34 C to 38 C)

Amoco Oil Co.


Atlantic Richfield Co.
Chevron U.S.A. Inc.
Cities Service Co.
Conoco Inc.
Exxon Company, USA
Gulf Oil Corp.
E.F. Houghton & Co.
Imperial Oil Ltd.
Kendall Refining Co.
Keystone Div. (Pennwalt)
Mobil Oil Corp.
Phillips Petroleum Co.
Shell Oil Co.
Standard Oil Co. (OH)
Sun Oil Company
Texaco Lubricants
Texaco Canada Inc.
Union Oil Co. (CA)
Valvoline Oil Co.

Amolith Grease #2
Litholene HEP 2
Chevron Dura-Lith EP-2
Citgo HEP-2
EP Conolith #2
Ronex MP
Gulfcrown Grease #2
Cosmolube #2
Esso MP Grease H
Kenlube L-421 Gease
#81 Light
Mobilux EP 111
IB & RB Grease
Alvania Grease #2
Factran #2
Prestige 42
Starplex HD2
Marfak HD 2
Union Unoba #2
Val-Lith EP #2

Amolith Grease #2
Litholene HEP 2
Chevron Dura-Lith EP 2
Citgo HEP 2
EP Conolith #2
Ronex MP
Gulfcrown Grease #2
Cosmolube #1
Lotemp EP
Kenlube L-427 Grease
#84 Light
Mobilux #1
Philube IB & RB Grease
Alvania Grease #2
Factran #2
Prestige 42
Multifak EP2
Marfak AP
Union Unoba #2
Val-Lith EP #2

Note:

Check with lube manufacturer for approved lubricants to use in the


food processing industry.

Temperature Operating Range:


0F (-18C) to 150F (66C)
Centrifuge Separation Characteristics:
Low oil separation rate and high resistance to
separation from centrifuging.
NLGI Grade: 2
Minimum Dropping Point: 190F (74C)

GD

The specifications indicated below are average values, variations


which do not affect product performance may occur.
Temperature Operating Range:
-40F (-40C) to 250F (121C)
Minimum Base Oil Viscosity:
2625SUS (567cSt) @ 100F (38C)
Centrifuge Separation Characteristics:
ASTM D-4425-K36 = 0/24
NLGI Grade: 1
Minimum Dropping Point:
225F (108C)
Minimum Timken Load: 40 lbs

Common Industrial Lubricants (NLGI Grade #2)

Lovejoy Coupling Grease Limited 5-year Lubrication Warranty


Since 1927, Lovejoy couplings have saved thousands of companies both
time and money by accommodating shaft misalignment, vibrations and
shock loads, thus protecting connected equipment.
Now Lovejoy Grid Couplings join this long tradition. For this design, we have
identified the best possible lubricants for couplings those with high
viscosity and low bleed rates. Lovejoy Coupling Grease meets these high
expectations and yours.
A Lovejoy Grid coupling initially lubricated with Lovejoy Coupling Grease
will have the grid spring member warranted for 5 years against lubrication
failures and provide rugged, dependable service. It's our guarantee!
Benefits for your application are:
Increased coupling life.
Reduced maintenance cost.
Reduced downtime.
Superior lubrication.
Significantly extended relubrication intervals.

Warranty
Lovejoy, Inc. will replace any grid member which fails during the first
five (5) years of normal use due to inadequate lubrication provided that:

The coupling was initially lubed with the proper amount of Lovejoy
Coupling Grease, as described in the Installation Instructions.

Recommended installation and operational alignment limitations


are observed.

Ambient temperatures are within -20 to +250F (-29 to +121C).

This guarantee of performance does not mean that a grid member will
never need to be replaced. The primary purpose of a coupling is to protect
the connected equipment by accommodating shaft misalignment and shock
loads. In performing this function, some wear and fatiguing of metal may
occur. However, if the grid member fails within the warranty period due to
some failure of the lubricant, Lovejoy will replace the grid member free
of charge.