SAP2000 Tutorial
SAP2000 Tutorial
SAP2000 Tutorial
Goel
Department of Civil and Environmental Engineering California Polytechnic State University San Luis Obispo, CA 93407
Geometric Model Start the program. Youll see the Graphic User Interface (GUI)
Units We take kN - m
select the units to be used in the analysis. Click on File Click on New Model from Template to get the following screen.
Choose a template that fits your need. For example, to generate a twodimensional frame, click on the second icon in the first row. The following information screen pops up.
3
This is an example regular frame, of equal story height and equal bay width! Specify the number of stories, number of bays, story height, and bay width. The units should be consistent with those selected in the first step. Click on OK and a basic outline of the model would appear on screen. This model has correct coordinates of all nodes.
Well show how to modify input data if each story or bay is of different size.
4
To change the boundary conditions, select joints and then click on the joint restraint icon (little triangle on the icon bar) to get the following screen.
Material Properties
If more than one material is used, repeat the process for each new material. Click on Define Click on Material to get the following screen.
The program has default properties of concrete and steel. If you want, you can add new material by clicking on Add New Material and following the directions. For checking or modifying properties of steel or concrete, click on Modify/Show Material. The following screen pops up. Check to see if these material properties are acceptable. If not, you can modify them by going to the appropriate box and re-entering the value.
CAUTION: If you specify non-zero value of weight per unit volume, the program by default would calculate the weight of structural elements and use them in analysis. If you specify value of Dead Load that contains the self-weight of structural elements, specify zero unit-weight (or turn it off later). Similarly, if your nodal masses contain mass due to self-weight, specify zero unit-mass.
Element Data
Define the element view options. Click on View and then on Set Elements to get the following screen.
Check all appropriate boxes under the Joint sections and Frame section.
10
It is also useful to check Options for Shrink Elements and Show Extrusions. The last option is useful in visually checking the correct orientation of beams and columns (more later on this). Click OK. To define frame section properties, repeat the following process as many times as different sections to be used in your analysis. Click on Define and then on Frame Sections to get the following screen.
11
There is default rectangular section FSEC1. You can modify this section, or you can Import or Add section. 1. To modify the existing section, select FSEC1 and then click on Modify/Show Section to get the following screen.
Select the appropriate Material. The material properties were defined earlier. Modify the Depth and Width. View the calculated properties of the section by clicking on Section Properties.
If you want to modify the properties, you can do so by clicking on Modification Factor and specifying the appropriate multipliers.
13
The properties shown are based on gross section (sectiunea bruta). For reinforced concrete, it is usual to consider moment of inertia to be a fraction of the gross inertia. That fraction could be entered as Property Factor in the Modification Factor screen (FSECi).
14
You can also import one of the predefined sections. For this purpose, go to the import drop box and click on a section type. For example, clicking on Import/Wide
Flange gives the following screen Choose the appropriate section, and click OK. If you are doing this for the first time, the program would ask you to choose from standard data files. For example, AISC properties are in aisc.pro. You can view the section from the Modify/Show option of the Define Frame Section box.
15
To assign section properties to each frame member, select all elements to which you want to assign the same section. Click on Assign, then on Frame Section to get the following screen. Choose the frame section that you want to assign to the selected frame elements and then click OK.
16
Completing the process gives you, for example the following structural model. Note that SAP by default places frame elements for strong axis bending. The axis can be changed by the following process, which is described by changing the local axis for one of the columns.
Select the element you want to change the local axis for.
17
Click on Assign then on Frame and then on Local Axes to get the following screen
To rotate the angle from default direction, say by 90 degrees, enter the desired Angle in Degrees and click OK. You would see the change in the direction of the columns as shown below.
18
19
After you have specified all elements and checked the orientation, it is useful to go back to the line diagram. This can be done by clicking View then Set Elements and then clearing the Show Extrusion box. You may also want to check on Frame Release to be able to view any member end releases. Shown below is the two dimensional model.
20
By default, SAP also considers that both ends of the frame member have rigid connections. A pin connection at any or both end, can be specified by selecting an element, then clicking on Assign then on Frame and then on Releases to get
21
Pin at ends can be introduced by releasing the moment in appropriate direction. It is also possible to release other quantities from the same screen. Following figure shows moments released at starting end of the beam at second story of first bay.
22
Static Analysis
Define static load cases by clicking on Define and then on Static Load Case to get the following screen.
23
You can specify a name for your load (e.g., DL, LL, EQ etc.) in the Load box and specify the load type in the Type box. Caution: If your specified load values include self-weight of the elements, you should specify Self Weight Multiplier to be zero. Otherwise, the self-weight would be counted twice. You can add as many load types as you need for your analysis. Load combinations can also be specified. For this purpose, click on Define and then on Combination to get the following screen.
24
Define as many combinations as desired. To add a new combination, click on Add New Combo to get the following screen.
25
Specify a Load Combination Name. From the Case Name drop box, select the load case and from the Scale Factor specify the multiplier. Built up your load combination by adding other load case. The figure shows a selection of 1.4 Load 1 + 1.2 Load 2. To specify loads at joints, select the joint, click on Assign, click on Joint Static Loads, and click on Forces to get the following screen.
26
Input the load value in appropriate box. Note that positive force is along positive axis direction. Select the Load Case Name from the drop box to associate the specified values to a particular load case. You can also modify an existing load by adding to it, replacing it, or deleting it by checking the appropriate box. Click OK to finish specifying load at the selected joint. Repeat the process for all joints that have applied loads. Static analysis can be performed by clicking on Analyze and then on Run or by clicking on the icon from the toolbar.
27
RESULTS
By default, SAP displays the deformed shape for the first load case. Displacements at a joint can be displayed by selecting the joint and then right clicking on the mouse.
To display other quantities, click on Display and picking the desired option.
28
To display element forces, click on Display, Show Element Forces/Stresses, and Frame to get the following screen.
29
Select the load case or combination and the component for which you want to display the element forces. For example, to display bending moment about strong axis, select Moment 3-3 to get the following diagram on screen.
30
To display numerical values, select an element and then right click on the mouse to get a smaller screen as shown below.
31
Values at different location can be displayed by moving the red dot along the element length.
32
Dynamic Analysis
Specify lumped masses at joint. For this purpose, click on Assign, Joint, and Masses to get the following screen.
33
Enter appropriate mass values. The units should be consistent with the units specified for your analysis. You can add this mass to existing mass, replace existing mass, or delete existing mass from the same screen. To get the mode shapes and frequencies, click on Analyze and then on Set Options to get the following screen.
34
Select the Available DOFs either by individually checking on various DOF or by clicking on Fast DOFs option. For example, for analysis of a frame in two dimensions, you would select Plane Frame. Check the box for Dynamic Analysis and then click on Set Dynamic Parameters to specify the number of modes to be determined.
35
You can change the mode shape that is displayed on screen from the Display tool or from clicking on the symbol at the bottom right corner of the screen. For dynamic response spectrum analysis, Define the Response Spectrum Function and then Response Spectrum Case using the procedure similar to that for static case.
37
For comparison with results from equivalent static analysis, in dynamic analysis it is useful to display base shear and base overturning moment. This can be done as follows. Define a group consisting of joints at the base and all elements connected to these joints. Click on Define and Groups to get the following screen.
38
Specify a name for the group in the Groups box and click on Add New Group Name. Click OK. Select a group of joints and the elements directly connected to only one side of them. For example if the base shear for a structure is required, the group should consist of the joints at the base of the structure and the frame elements above them that are directly connected to them. Click on Assign and Group Name to get the following screen.
39
Select the name in the Groups box that needs to be assigned to the selected group. Click OK. To display results for this group, after the analysis has been completed, click on Display and Show Group Joint Force Sum. The following screen would display the results.
40
Modifying Model After you have run the analysis once, the model should be unlocked from the toolbar. This would cause all the analysis results to be deleted. Make whatever changes are necessary and rerun the model.
41