Index: English 1-8 Francais N/A Deutsch N/A Italiano N/A Espafiol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Hollands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Portugues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A Suomalainen N/A Norsk N/A Svensk N/A <P::lC N/A N/A
B*~
1.0 IMPORTANT
RECEIVING
INSTRUCTIONS ~ ~ _ ~
Visually inspect all components for shipping damage. Shipping damage is not covered by warranty. If shipping damage is f?und, notify carrier at once. The carrier is responsible for all repair and replacement costs resulting from damage in shipment.
DANGER: To avoid serious personal injury, keep hands and feet away fr~m ~ydraulic c~linder and related components durinq Jack operation.
SAFETY FIRST
2.0 SAFETY ISSUES
DANGER: Do not handle pressurized lines. Escaping oil under pressure can penetrate the skin~ causing serious ~7'- injury. If oil is injected under the skin, see a doctor immediately. WARNING: The jack's internal relief valve must not be repaired or adjusted except by an authorized service ~ center. Never tamper with overload protection devices. Higher settings may result in equipment damage and/or personal injury.
Read all instructions, warnings and precautions ill carefully. Follow any recommended safety precautions to avoid personal injury or damage to the jack. Enerpac cannot be responsible for any damage or injury from unsafe use, lack of maintenance or incorrect operation. Do not remove warning labels, tags, or decals. In the event any questions or concerns arise, contact ENERPAC or a local Enerpac distributor for clarification.
Ii\
rn
Iy\
The jack hydraulic system's maximum working pressure is 6,000 to 10,200 psi [414 to 703 bar], depending on model. Refer to pressure listings in Table 1, General Specifications. If you have never been trained on high-pressure hydraulic safety, consult your distributor or service center for a free Enerpac Hydraulic Safety Course. A CAUTION is used to indicate correct operating or maintenance procedures and practices to prevent damage to, or destruction of equipment or other property. A WARNING indicates a potential danger that requires correct procedures or practices to avoid personal injury. A DANGER is only used when your action or lack of action may cause serious injury or even death. Failure to comply with the following safety precautions result in equipment damage and/or personal injury: could
CAUTION: When jack is not in use, fully retract the cylinder and protect the entire unit from external dam~ge. ~ Keep the jack clean, avoid weld splatter, and store In a clean dry area. INSPECT ALL JACK COMPONENTS BEFORE USE.
Iy\
~
CAUTION: Keep the jack away from flames and heat. For optimum performance, do not expose the jack to temperatures above 65C [150 "F].
WARNING: BE SURE LIFTING ARRANGEMENT IS STABLE BEFORE LIFTING LOAD. Use jack on solid ~ surface capable of supporting the load and the base of the jack. Always center the load on the lifting saddle of the jack. If the jack is not perpendicular to the load, slipping or loss of load is possible.
Iy\
ii
%
WARNING: Distribute the load evenly when performing lifts with multiple jacks. Failure to heed this warning may cause loss of load and/or failure of the jack, resulting in property damage and/or personal injury.
WARNING: Wear proper personal protective gear when operating hydraulic equipment. WARNING: The jack is to be used for lifting only! Support the load after completing the lift using approved accessories or by other appropriate means. Never get under a load being supported only by the jack. , ~ WARNING: Never exceed the rated capacity of the jack. Allow for a margin of safety that accounts for possible shifting loads or side loading conditions.
......., IMPORTANT: Hydraulic equipment must only be I) serviced by a qualified hydraulic technician. For repair service, contact the Authorized ENERPAC Service Center in your area. To protect your warranty, use only ENERPAC oil. WARNING: Immediately replace worn or damaged parts with genuine ENERPAC p~~s. Standard grade parts will oft!!! break causing personal Injury and property damage. ENERPAC parts are designed to fit properly and withstand high loads.
Ii1
II
r
PRASA200 -- L Maximum Hydraulic Oil Temperature Hydraulic Reservoir Oil Capacity (approximate - when filled to proper level) Air Requirements (minimum) 170 of [76C) 4.2 gallons [15,9 liters] 50 CFM @ 80 psi [14161/min @ 5,5 bar]
Key: 1. Handle Lock Lever 2. Handle Assembly 3. Lifting Bar* 4. Air Supply Valve 5. Control Valve, Manual 7. Air Line Lubricator 8. Reservoir Air Breather 9. Air Line Filter/Regulator 10. Air Inlet Connection 11. Oil Fill Plug 12. Oil Filter 13. Hydraulic Cylinder 14. Hydraulic Reservoir 15. Oil Drain Plug 16. Air Muffler 17. Lifting Eyebolt* 18. Wheel Bearing Grease Fitting 19. Tire Air Valve
*Not present on all models.
10
11 12 2
8-+-+-f-H
(1/2" NPT)
14
15
Key:
10
11
2
1. Handle Lock Lever 2. Handle Assembly 3. Lifting Bar* 4. Air Supply Valve 5. Control Valve,Air Operated 6. Pendant 7. Air Line Lubricator 8. ReservoirAir Breather 9. Air Line Filter/Regulator 10. Air Inlet Connection (1/2" NPl) 11. Oil Fill Plug 12. Oil Filter 13. Hydraulic Cylinder 14. Hydraulic Reservoir 15. Oil Drain Plug 16. Air Muffler 17. Lifting Eyebolt" 18. Wheel Bearing Grease Fitting 19. Tire Air Valve
*Not present on all models.
16
5 3
15
3.
The jack can now be tilted back onto the wheels and pushed or pulled to the work area. Use caution when walking backwards. If necessary, the jack can be lifted using the lifting bar (callout #3 - if equipped) or the lifting eyebolt(s) (callout #17 - if equipped).
4.
ill
/1\
WARNING: Never attempt to lift the jack by using the handle assembly. ~he handle assembly is to be used only for roiling the Jack on Its wheels - not for lifting.
Note: Lifting bars are installed on short stroke PRAMA060 PRA A 100 and PRASA 150 Series models. Lifting bars are not u~ed o~ any long stroke models or on short stroke model PRASA20016L. All long stroke models are equipped with one lifting eyebolt. The short stroke model PRASA20016L is equipped with two lifting eyebolts. Lifting eyebolts are not present on short stroke PRAMA060, PRA_A 100 and PRASA 150 Series models.
Note: On PRASA Series models, the air operated directional control valve is in the center (neutral/hold) position when the pendant buttons are not depressed. 2. Connect an air hose at the air inlet connection (callout #10). Note: On PRAMA Series models, the motor will start immediately when the air supply valve is opened. On pendant controlled PRASA Series models, the motor will start automatically when either pendant button is depressed. 3. 4. Open the air supply valve (callout #4). Using the regulator knob, adjust the air pressure to a minimum of 80 psi [5,5 bar]. Shift the control valve (callout #5) to the advance and retract positions and look for movement in cylinder. For PRASA Series models with pendant control, use the buttons on pendant (callout #6) to control cylinder movement.
2.
4-Way Air Operated Valve with Pendant: To advance cylinder - depress up-arrow button. For neutral/hold - release both pendant buttons. To retract cylinder - depress down-arrow button. 4. Lifting speed and torque can be regulated by using the air pressure regulator. The regulator should be adjusted to 100 psi [7 bar) maximum with air motor running and air supply valve completely open. IMPORTANT: Pressure settings of above 100 psi [7 bar) will result in reduced air motor life. Manual Valve: Center position is neutral/hold. 3.
CAUTION: When lifting with more than one jack, be , especially careful to keep the load level. Leveling is best ~ accomplished by throttling with the air supply valve or by alternating and stopping jacks to keep the load level enough to be stable. 5. When load has reached the proper level, move the control valve lever to the center (neutral/hold) position. If jack is equipped with pendant, release up-arrow button to return valve back to the center (neutral/hold) position. Be sure that the proper Enerpac U-Rings are installed on the cylinder (refer to Section 5.7 for U-Ring installation and stacking instructions). If U-Rings are not used, be sure that support stands of appropriate load rating are in place. Move the control valve lever to the retract position. Allow the load to lower until it is supported by U-Rings or support stands. Then, return the lever to the center (neutral/hold) position. If jack is equipped with pendant, depress and release the down-arrow button as required, until the load is supported by U-Rings or support stands.
6.
Air Operated Valve: Valve stays in center (neutral/hold) position until Down-Arrow or Up-Arrow button is pressed.
Down-Arrow (Retract) Up-Arrow (Advance)
7.
WARNING: After lifting is completed, always support , the load using the proper Enerpac U-Rings or ~ appropriately rated support stands. Never rely on the cylinder's hydraulic pressure to support the lifted load. Figure 3, Control Valve and Pendant Details IMPORTANT: if there is to be no cylinder movement for more than one minute, it is recommended that the motor be turned off to prevent overheating (models with manual directional control valve only). TO LOWER THE LOAD: 1. Be sure the control valve lever is in the center (neutral/hold) position. If jack is equipped with pendant, be sure that both buttons are released (not pressed) so that valve returns back to the center position. Open the air supply valve. On models equipped with a manual directional control valve, the motor will start. Shift the control valve lever to the advance position or depress the pendant up-arrow button. Allow cylinder to advance a small amount, so that load clears the support stands or U-Rings. Then place the control valve lever in the center (neutral/hold) position or release the up-arrow button. After the support stands or U-Rings are removed, move the control valve lever to the retract position or depress the pendant down-arrow button to retract the cylinder. , CAUTION: Be careful while lowering to ensure that the load is lowered evenly, so that load shifting does not occur.
2. 3.
ill II\!
~
11\
WARNING: Never crawl under or place any part of your body under any load at any time while it is being lifted, by the Pow'r-Riser jack.
WARNING: The Pow'r-Riser jack is intended for lifting purposes only and should not be used to hydraulically support the load for any period of time after the lift has been completed. Support the load with U-Rings or support stands immediately after it has been lifted to the desired height. WARNING: Never leave the Pow'r-Riser jack unattended during operation, even for a brief period of time. Closely monitor jack operation at all times and be prepared to stop lifting or lowering immediately.
4.
ill
11\
5.
When cylinder has fully retracted, place the control valve lever in the center (neutral/hold) position or release the pendant down-arrow button. On models with manual directional control valve, close the air supply valve to stop the motor.
When using PRE Series extensions and/or PRS Series spacers, always obey the following rules: For loads up to 60 tons [54 metric tons]: Any two PRE Series extensions may be included in the stacking arrangement, provided that the maximum stack height (See Table 5) is not exceeded and the following exceptions are observed: 1) Jack model PRAMA06014L: Only one PRE18 extension can be included in the stacking arrangement. 2) All jack models ending in "16L": Only one PRE11, PRE14 or PRE18 extension can be included in the stacking arrangement. 3) All jack models ending in "27L": Extensions PRE14 and PRE18 cannot be included in the stacking arrangement. These extensions are designed for short stroke jacks only (models ending in "14L" and "16L"). For loads over 60 tons [54 metric tons], or strokes over 14 inches [356 mm]: Only one PRE Series extension and one PRS Series spacer can be included in the stacking arrangement. Never exceed 3 inches [76 mm] in total spacer height. Never exceed the maximum additional stack height for your jack model. Refer to Table 5, dimension "X". Table 3 - PRE Series Extensions (optional accessories) Extension Model PRE5 PRE7 PRE9 PRE11 PRE14* PRE18* PRES6024 Extension Set Thickness (each) inches 5 7 9 11 14 18 mm 127 178 229 279 356 457
&
,
CAUTION: Never exceed the maximum additional stack height for your jack model. Refer to Table 5 for additional information.
* For use on short stroke jacks only (models ending in "14L" or "16L")
~----Load Cap (see Table 6) Table 4 - PRS Series Spacers (optional Spacer Model inches 1 2 3 accessories) mm 25 51 76
Thickness (each)
I [ J I... r-----
PRS1 PRS Series Spacer (see Table 4) PRS2 PRS3 PRS4 Spacer Set
P);:~>::Y~;.~\::r---
Table 5 - Maximum Additional Stack Height USing Optional PRE Series Extensions and PRS Series Spacers Jack Model PRAMA06014L Maximum Additional Stack Height (dimension "X") inches 32 11 21 11 21 11 21 11 21 11 mm 813 279 533 279 533 279 533 279 533 279
Ea, ,
~L::
L;,'
:;;,>~
t.'"
Cylinder Rod
Ii\. ill
WARNING: Failure to observe the following instructions could allow load to shift or drop. Serious personal injury and/or property damage may result.
5
PRASA20016L PRASA20027L
Steel U-Ring
PRAMA06014L PRTS60
(See Figure 5)
Locking U-Rings (optional accessories) allow positive mechanical load holding of a lifted load. The U-Rings are placed around the extended cylinder and are available in four different lengths for each Pow'r-Riser model. The jack is designed so the U-Rings are properly positioned on top of the lifting cylinder housing using mating locators and recesses. Assemble the U-Rings on top of the cylinder housing, around cylinder rod with a one-inch thick [25 mm] steel U-Ring at the top and bottom of the stack. Assemble aluminum ring or rings between the steel rings on cylinder. , CAUTION: An aluminum U-Ring must positioned on the end of a U-Ring stack. never be
Figure 5, U-Ring Stacking Arrangement IMPORTANT: Follow all applicable work rules and regulations in effect at your facility or worksite. The use of auxiliary stands, blocking or other additional work supports may be required even when U-Rings are installed.
The quantity of aluminum U-Rings installed depends on the U-Ring set being used. Refer to Table 7 for additional information.
Items Included in Each U-Ring Set U-Ring Set Model Number PRUS126 PRUS137 PRUS126 PRUS137 PRUS126 PRUS137 PRUS1526 PRUS1537 PRUS2026 PRUS2037 2x 1x 2x 1x
PRAMA06014L PRAMA06027L PRAMA10016L PRAMA 10027L PRASA10016L PRASA 10027L PRASA 15016L PRASA 15027L PRASA20016L PRASA20027L
PRU11 PRU11 PRU11 PRU11 PRU11 PRU11 PRU151 PRU151 PRU201 PRU201
PRU13 PRU13 PRU13 PRU13 PRU13 PRU13 PRU153 PRU153 PRU203 PRU203
PRU110 PRU110 PRU110 PRU110 PRU110 PRU110 PRU1510 PRU1510 PRU1510 PRU1510
PRU11 PRU11 PRU11 PRU11 PRU11 PRU11 PRU151 PRU151 PRU201 PRU201
PRU13 PRU13 PRU13 PRU13 PRU13 PRU13 PRU153 PRU1510 PRU203 PRU2010
PRU14 PRU14 PRU14 PRU14 PRU14 PRU14 PRU155 PRU155 PRU205 PRU205
Filter Bowl
Lubricant Reservoir
1fl!'~-+11--
Water Drain
[60C].
A high humidity environment temperature that can result reservoir. and/or extreme in condensation changes in inside the
Dirty or dusty environments that may contaminate the oil. Change the oil as described in the following steps: 1. Be sure that cylinder is fully retracted and that the air line is disconnected.
IMPORTANT: The 5 gallon [18,9 liter] hydraulic reservoir holds approximately 4.2 gallons [15,9 liters] of oil when filled to the proper level with cylinder fully retracted and motor off. Dispose of used oil in accordance with all applicable laws and regulations. 2. 3. 4. Loosen and remove oil drain plug at bottom of reservoir. Allow used oil to drain into a suitable container. Clean and reinstall oil drain plug. Remove, clean and reinstall the reservoir air breather. It is located on the reservoir top cover plate, under the air filter/ regulator assembly. Loosen oil fill plug at top of reservoir. Slowly fill the reservoir until the oil level is about 1 inch [25 mm] below the reservoir top cover plate. Use only Enerpac HF hydraulic oil. Reinstall oil fill plug. Remove the old oil filter and replace it with a new one of the proper specifications. Catch any spilled oil in a suitable container. Raise and lower the cylinder several times to check for proper operation before placing the jack back into service. Figure 8, Additional Maintenance Items --z<'\"\._.-lr'r--:::.::,Tire Air Valve
5.
6. 7.
8.
(See Figure 7)
Check the filter bowl for water. Drain any water if present. Inspect air filter element element if dirty. (inside filter bowl). Replace filter
7.0 TROUBLESHOOTING
The information problems in the Troubleshooting Guide (refer to Table 8) is intended as an aid to help diagnose and correct various possible that may occur. contact your local Enerpac Authorized Service Center. Only an Enerpac Authorized Service Center should service
Internal pressure leaks, or leaking retract hoses. Internal relief valve setting or retract side relief valve setting too low. Defective over-center valve or defective secondary lock valve. Pump not developing enough pressure. 6. Pump does not run. Insufficient compressed Moisture in compressed air volume. air.
Clean the air muffler. Be sure compressed air is clean, dry and free of water. Check lubricant level in air line lubricator. Use only SAE 10 [ISO 32) detergent oil or an approved antifreeze lubricant. Be sure compressed air is clean, dry and free of water. Check lubricant level in air line lubricator. Use only SAE 10 [ISO 32] detergent oil or an approved antifreeze lubricant. Check tire inflation [6,2 bar). pressure. Add air if low. Pressure should be 90 psi
to roll
Low tire inflation pressure. Wheel bearings need lubrication. Wheel locknut out of adjustment.
Apply grease to wheel bearings. See Section 6.6. Loosen locknut until wheel rotates freely.
EC DECLARATION OF CONFORMITY
We, ENERPAC, a Division of ACTUANT, located at
WI. 53925.
U.S.A.,
declare under our own responsibility that the below mentioned products:
Enerpac Air-powered Pow'r-Risers of the following model numbers: PRAMAxxxxxx & PRASAxxxxxx.
on which this declaration refers to are, where applicable, in accordance with the harmonized European Standards: EN982:1996. Safety of Machinery - Hydraulics, EN983:1996. Safety of Machinery - Pneumatics, ENI050:1997. Safety of Machinery - Principles of Risk Assessment, EN-ISO 12100-1:2003. Safety of Machinery - Basic Terminology & Methodology, and EN-ISO 12100-2:2003. Safety of Machinery - Technical Principles
as well as national standards and/or technical specifications: - ANSI B30.1:2009. Safety Standards for Hydraulic Jacks
(And, as per Annex II of the Directive on Machinery), We point out that it is forbidden to put the above mentioned products into service until the final machinery into which these are to be incorporated has been declared in conformity with the provisions of this Directive.
EC2B-PRA