Miniature Pyrometer CellaTemp PM 11

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Miniature Pyrometer

Series CellaTemp® PM

Measuring ranges 0 to +1200 °C


Dimensions 36 x 20 x 52 mm
Very good optical characteristics
due to precision lenses with broad
band antireflection coating
Microcontroller controlled
linearization
External emissivity adjustment

MEASURING · CONTROL · SYSTEMS


The miniature-pyrometer CellaTemp® PM The emissivity for the adjustment of
is as small as a thumb. the pyrometer to the radiation charac- Target Diagrams
The optic, complete electronic as well teristics of the measuring object is
as the linearization and ambient externally adjustable.
temperature compensation are
PM 11 Target diameter/[mm]
situated in a housing of only Because of its non-hygroscopic preci-
36 x 20 x 52 mm. sion lens and its waterproof metal hou-
The linear analogue output can be sing, the CellaTemp® PM provides the
easily connected to commercial digital user with exact and reliable measuring
displays, automatic controllers or to a results even under very rough industri- Distance/[mm]
PLC without any additional electronic. al conditions.

PM 21 Target diameter/[mm]
Technical Data

Type PM 11 AF 1 PM 11 AF 2 PM 21
Measuring range AF 1: 0 to +200 °C – +300 to +800 °C Distance/[mm]

AF 2: – 0 to +400 °C +700 to +1200 °C


Resolution 1.0 K 2.0 K 3.0 K
Repeatabillity ≤ 2.0 K ≤ 3.0 K ≤ 3.0 K
(for ε = 1 and Tu = constant) Accessories
Accuracy ≤ 3.0 K ≤ 1 % of reading ≤ 5.0 K
+1 K or 4 K
(for ε =1 and Ta = 23 °C)
Axial air nozzle
Sensor Thermopile Photodiode Mounting angle
Spectral sensitivity 8 to 14 µm 1.0 to 1.7 µm Power supply
Distance ratio 15:1 at a measuring distance of 100 mm 30:1 Digital display
6.4:1 at far distances
Calibration certificate
Target size ø 6.6 mm at a measuring distance ø 5 mm at a
of 100 mm measuring distance
of 150 mm
Analogue output 10 mV/°C linear 1 mV/°C linear Dimensioned drawing
AF 1: 0–2 V – 300 mV–800 mV
AF 2: – 0–4 V 700 mV–1200 mV
Response time t90: 200 ms t98: <200 ms
Load resistance ≥ 10 KΩ 40
36 3 5 30
Admissible ambient 0 to +60 °C with less
temperature accuracy up to 80 °C Ø 4.5
M16x0.75
Ø 19.6

Storage temperature –20 to +80 °C


20

Temperature coefficient ≤ 0.07 % of reading/K or 0.1 K/K


52 ± 1

Ø9
deviation to Ta = 23 °C
Power supply 11–27 V DC ≤ 10 mA, ripple ≤ 200 mV
Air moisture
MSR/16/W/024/E · Printed in Germany · Technical changes reserved.

Max. 95 % r. H. (non condensing)


Dimensions Pyrometer 36 x 20 x 52 mm (L x W x H)
fixing plate 40 x 20 mm Ø 18

Housing material nickel-plated metal


Connection Via cable 5 m
Weight Approx. 150 g
Protection IP 65 according to DIN 40050
Adjustable Parameters
Emissivity ε: 20–100 % adjustable

CellaTemp® PM is a registrated trade mark of KELLER HCW GmbH, Ibbenbüren, Germany.