D 102310 X 012

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Dirty Service Trim

D102310X012

Product Bulletin

80.2:021 June 2012

Fisherr Dirty Service Anti-Cavitation Trim (DST)


Fisher Dirty Service Trim (DST) is a multi-stage, anti-cavitation control valve trim for use in services where the fluid may have entrained particulate that could plug the passages, or cause erosion damage to conventional anti-cavitation trims. DST is frequently used in high pressure drop applications up to 4200 psid in the chemical, refining, oil and gas production, and power industries.

Features

Cavitation Control2-, 3-, 4-, 5-, or 6-stage DST used in a valve properly selected for flow conditions can eliminate cavitation and associated damage and noise. VersatilityAvailable in globe and angle valves, flow down (figure 2) or flow up (figure 3), from NPS 1 to 16 having weld-end or flanged-end connections. Can be used in easy-et, EH, EHA, EW, HP, and HPA valves. Long Trim LifeThis trim concept uses a combined axial and radial flow that features large, open flow paths and decreased clearance flow erosion. Flexibility In many cases DST can be retrofitted to replace Cav III trims that are currently in service. DST can pass 1/4 to 3/4 inch particles without plugging. Easy MaintenanceIn-line trim removal allows inspection of parts without taking the valve body out of the pipeline. Sour Service CapabilityMaterials are available for applications handling sour fluids. Please contact your local Emerson Process Management sales office for additional information.

W6787-1

Fisher Dirty Service Trim

Trim MaterialsTypical trim materials include S17400 cages, S44004 valve plug and seat, S31600/ENC/CoCr-A cages with S31600/CoCr-A valve plug and seat, or S32550/ENC/CoCr-A cages with S32550/CoCr-A valve plug and seat. Other materials are available to satisfy application requirements. ShutoffDST also features a protected seat design where the shutoff function of the valve is separate from the throttling areas of the trim. High-Temperature Class V ShutoffUse of the metal C-seal permits Class V shutoff above 316_C (600_F).

www.Fisher.com

Product Bulletin
80.2:021 June 2012

Dirty Service Trim

D102310X012

Specifications Available Valves easy-e, EH, EHA, EU, EW, HP, and HPA. See table 3 End Connection Styles Refer to appropriate valve bulletin Valve Body Dimensions and Weights Valve type, pressure class, and number of stages will result in changes to these values. Please consult your Emerson Process Management sales office for more information on finished dimensions and weights Shutoff Classifications Class V per ANSI/FCS 70-2 and IEC 60534-4 Maximum Inlet Pressures and Temperatures(1) Consistent with applicable CL150, CL300, CL600, CL900, CL1500, and CL2500 pressure/temperature ratings according to ASME B16.34 ratings unless limited by individual temperature and pressure limits shown in tables 1 and 2 Maximum Pressure Drop(1) See table 1 Construction Materials Trim Parts: S17400 cages, S44004 valve plug and seat or S31600/ENC/CoCr-A cages with S31600/CoCr-A valve plug and seat. S32550/ENC/CoCr-A cages, S32550/CoCr-A valve plug and seat. Trim can be made from several other bar stock alloys. Consult your Emerson Process Management sales office for your specific application Temperature Capabilities Valve Body/Trim Combinations: See table 2 All Other Parts: Consult your Emerson Process Management sales office Flow Coefficients See table 3 Flow Characteristic Linear Flow Direction Flow down (typical) or Flow up (available) Valve Cavitation Coefficient Kc = 1.0 for all valves when trim is used within applicable pressure drop limits. Maximum Valve Plug Travel Typical plug travels are 0.75 inch through 2 inch. Contact your Emerson Process Management sales office for your specific application Minimum Seating Force Use Class V seat load requirements

1. The pressure/temperature limits in this bulletin and any applicable standard or code limitation for valve should not be exceeded.

Contents
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Principle of Operation . . . . . . . . . . . . . . . . . . . . . . . . . Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trim Selection Guidelines . . . . . . . . . . . . . . . . . . . . . . Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valve Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . . . 1 2 3 3 4 4 4 Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . . . Tables Available Pressure Drop Limits . . . . . . . . . . . . . . . . . DST Availability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trim Combinations for DST . . . . . . . . . . . . . . . . . . . . Typical Applications . . . . . . . . . . . . . . . . . . . . . . . . . . 4 3 5 4 8

Dirty Service Trim


D102310X012

Product Bulletin

80.2:021 June 2012

Table 1. Allowable Pressure Drop Limits


PRESSURE DROP LIMITS Number of Stages 2 3 4 5 6 Flowing Pressure Drop Limit (bar) 52 103 207 241 289 Flowing Pressure Drop Limit (psi) 750 1500 3000 3500 4200 Fl 0.95 0.97 0.99 0.99 0.99 Kc 1.0 1.0 1.0 1.0 1.0

Figure 1. Staged Pressure Drop Patterns

are not worn away by throttling control action, (valve must always be throttled above the min Cv) resulting in extended shutoff capabilities. In conventional staged-trim designs, cavitation usually does not exist until the final stage. Figure 1 illustrates why this happens. As shown, the greater the pressure drop through the final stage, the lower the vena contracta pressure (Pvc). If Pvc is less than or equal to Pv, and P2 is greater than Pv, then cavitation will result. The DST valve avoids this by means of its unique expanding flow area design. Each of the stages has a successively larger flow area. The result is a very efficient operation because more than 90 percent of the overall pressure drop is taken in the stages prior to the final stage where there is little danger of bubble formation. Consequently, a relatively low inlet pressure to the final stage is achieved. Figure 1 also compares the pressure drop pattern through the four stages in the expanding area DST design with a pattern representing a six-stage trim design with each stage taking an equal portion of the total pressure drop. As can be seen, the inlet pressure to the last stage of DST trim is always less than the inlet pressure to the sixth stage of an equal-drop cage. Therefore the Pvc of the DST cage remains higher than the Pvc of an equal-drop cage. If the pressure drops were all equivalent to that of the last stage in DST trim, 11 stages would be required in the equal-drop trim.

EQUAL DROP THROUGH SIX STAGES

DST 4-STAGE TRIM

INLET PRESSURE TO FINAL STAGE

A2149-1

FLUID TRAVEL THROUGH THE VALVE STAGES

Principle of Operation
DST provides cavitation control for applications with entrained particulate that could potentially plug the inlet passages or cause severe erosion damage to conventional anticavitation trim. The DST design uses a combined axial and radial flow path that features large openings allowing particulate up to 3/4 inches in diameter to pass through the valve. Due to the need for tight shutoff, the multi-stage design incorporates a protected seating surface that separates the shutoff and the throttling locations. All significant pressure drops are taken downstream of the seating surface. As a result, the seating surfaces

Availability
DST trim is available in numerous body designs and pressure classes. Table 1 shows the pressure drop limits for each design relative to the number of stages used. Table 3 shows the different valve constructions that DST can be used in. It also shows typical min and max Cv values each valve can achieve. Any deviation from the sizes listed in table 3, or temperatures in table 2, will result in different Cv limitations. Please contact your Emerson Process Management sales office for any requests that do not fall within these ranges.

Product Bulletin
80.2:021 June 2012

Dirty Service Trim

D102310X012

Table 2. Trim Combinations for Fisher DST(1)


TRIM DESIGNATION A B C VALVE BODY MATERIAL WCC WCC SST WCC SST VALVE PLUG S44004 S31600/CoCrA S32550/ CoCrA CAGE S17400 S31600/CoCrA/ENC S32550/CoCrA/ENC SEAT RING S17400 or S44004 S31600/CoCrA/ENC S32550/CoCrA/ENC MAXIMUM TEMPERATURE LIMIT _C 316 204 316 316 204 _F 600 400 600 600 400

1. Contact your Emerson Process Management sales office for higher temperature capabilities.

Trim Selection Guidelines


The standard trim materials are listed below, and in table 2. Other materials such as superaustenitic SST, S34700, Solid CoCr-A, N08800, and tungsten carbide trim are available upon request. Contact your Emerson Process Management sales office for more information.

flow for the first 10-15% travel. Special characterizations may be possible, including special low minimum Cv designs. Contact your Emerson Process Management sales office for assistance.

Valve Sizing Guidelines


Sizing procedures from Catalog 12 or Fisher Specification Manager can be used to size DST control valves. Noise calculations are best performed by using Fisher Specification Manager. The multi-stage configuration of the DST design reduces valve trim noise significantly. Select CAV III 2-Stage as the valve type in Fisher Specification Manager to perform the noise prediction calculation.

Trim A: Trim A is the typical trim used with carbon steel and alloy steel valve bodies. It can generally be used in severe service applications up to 316_C (600_F). Higher temperature can be achieved with alternate trim parts. Contact your Emerson Process Management sales office for higher temperature requirements. Typical applications for Trim A include boiler feedwater, water, non-sour hydrocarbons, and other non-sour liquids. Trim B: Trim B is the typical trim used with stainless steel valve bodies. It can generally be used in severe service applications up to 316_C (600_F). Higher temperatures can be achieved with alternate trim parts. Contact your Emerson Process Management sales office for higher temperature requirements. Typical applications for Trim B include produced water, water, sour hydrocarbons, and other sour liquids. Not for use with boiler feedwater. Trim C: Trim C can commonly be seen in carbon steel and Duplex SST valve bodies. This trim is most commonly used in sea water applications, produced water, and other offshore crude oil applications.

Ordering Information
When ordering, specify: Application Information 1. Process Liquid: State particle size and type of entrained impurities, if any. 2. Specific gravity of liquid 3. Temperature and vapor pressure of liquid 4. Critical pressure 5. Range of flowing inlet pressures 6. Pressure drops a. Range of flowing pressure drops b. Maximum at shutoff 7. Flow rates a. Minimum controlled flow b. Normal flow c. Maximum flow 8. Required Cv 9. Line size and schedule

Please contact your Emerson Process Management sales office for more information on DST trim.

Characteristics
The DST trim is designed to have a linear flow characteristic. It is also designed to have no significant

Dirty Service Trim


D102310X012

Product Bulletin

80.2:021 June 2012

Table 3. Fisher DST Flow Down Availability(4)


VALVE DESIGN PRESSURE RATING VALVE SIZE NPS 1(5) 1.5(5) 2 easy-e Globe CL600 2.5 3 4 6 8 2(5) easy-e Angle CL600 3 4 6 2 3 4 CL1500 EH 6 8 10 12 14 CL2500 3(5) 4(5) 4 CL1500 EHA CL2500 EU CL600 6 8 4(6) 6(6) 12 16 4X2 EW CL600 6X4 8X6 12X8 3 HP CL1500 4 6 HP & HPA CL1500 CL2500 1(5) 2(5) 1(5) 2(5) PORT SIZE inch 0.875 1.125 1.75 2.188 2.50 3.438 4.375 5.375 1.125 2.188 2.50 3.438 1.50 1.875 2.875 3.625 5.375 5.375 8.00 8.00 1.50 1.875 1.875 2.875 3.625 3.625 2.875 8.00 11.00 1.75 3.438 4.375 5.375 1.875 2.875 3.625 0.875 1.25 0.875 1.00 TRAVEL inch 0.63 0.75 0.75 0.75 0.75 1.25 1.50 2.00 0.75 0.75 0.75 1.25 0.75 1.00 1.50 1.75 1.50 1.50 2.00 2.00 0.75 0.75 1.00 1.50 1.75 1.75 1.50 1.50 4.00 0.75 1.25 1.75 2.00 1.00 1.00 1.50 0.63 0.75 0.63 0.75 UNBALANCED AREA inch2 0.610 0.800 0.029 0.061 0.041 0.118 0.154 0.206 0.800 0.061 0.041 0.118 0.051 0.031 0.047 0.118 0.142 0.142 0.350 0.350 0.780 1.534 0.031 0.047 0.118 0.118 0.047 0.350 0.490 0.029 0.118 0.154 0.142 0.031 0.047 0.118 0.589 0.785 0.589 0.785 1.7 2.8 5.5 10
(1) (1)

MINIMUM AND MAXIMUM FLOW COEFFICIENTS, Cv (3) 2-Stage Min


(1) (1)

3-Stage Min 0.15 0.22 Max 4.4 8.9 18.5 23.4 36 64 128 185 8.9 23.4 36 64
(1) (1)

4-Stage Min Max NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) 0.3 0.58 7.5 23 44 88.5 115 115 298 298
(1)

6-Stage Min Max NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2)
(1) (1) (1) (1) (1) (1) (1) (1)

Max

0.3 0.5 0.8 1.7 2.8 5.5


(1)

23.1 30.5 46 81 174 253 30.5 46 81 NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) 382

0.22 0.4 0.8 1.5 2.8 5 0.22 0.4 0.8 1.5

0.5 0.8 1.7

1.4 1.2 4 4
(1) (1)

54 106 147 147

1 1 3 3 10 10 0.5 0.45

NA(2) NA(2)
(1)

0.4 16 19.2 44 88.5 86 46 1 NA(2) NA(2) NA(2) NA(2) NA(2) NA(2)


(1) (1) (1) (1) (1) (1)

9.4 13.7
(1) (1) (1) (1)

0.5

1.4 1.2 NA(2) NA(2) 10 10 0.22 81 1.5 2.8 5 0.65 1 1.2


(1)

54 105

1 1 1 1 NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) 0.45 1 1 0.09 0.28


(1) (1)

28

292 617 18.5 64 150 185 24.8 39.5 89.3 8.3 NA(2) NA(2)

187 253 NA(2) NA(2) NA(2) NA(2) NA(2) NA(2) NA(2)

19.4 34.6 71 3.2 7.1 0.3

0.2

4.3

1. Consult your Emerson Process Management sales office. 2. Construction not available. 3. 5-stage DST is available upon request. 4. For flow up constructions consult your Emerson Process Management sales office. 5. Unbalanced constructions. 6. These valves are from block forged angle valve bodies. Cast valve bodies are available and may change these values.

Product Bulletin
80.2:021 June 2012

Dirty Service Trim

D102310X012

Figure 2. 4-Stage Fisher DST Flow Down Trim

STEM

NUTS STUDS BONNET UPPER CAGE BONNET SPACER

SEAT RING

SEATING AREA MIDDLE CAGE

VALVE BODY

PLUG

LOWER CAGE

CLOSED

OPEN

Dirty Service Trim


D102310X012

Product Bulletin

80.2:021 June 2012

Figure 3. 3-Stage Fisher DST Flow Up Trim


STEM NUTS STUDS BONNET BONNET SPACER UPPER CAGE

LOWER CAGE VALVE BODY

CLOSED
W9632-2

PLUG SEAT RING

OPEN
W9631-2

Product Bulletin
80.2:021 June 2012

Dirty Service Trim

D102310X012

Table 4. Typical Applications


Boiler feed pump recirculation Desuperheater spray water control POWER/COGENERATION Feedwater start-up regulators Condensate pump recirculation Superheater bypass Water injection pump recirculation Produced/waste water injection well control OIL AND GAS PRODUCTION Separator letdown Chemical injection pump bypass Main oil line or export flow control valve Main oil line or export pump recirculation NATURAL GAS PROCESSING Contactor (rich amine) letdown Rich and lean amine pump spillback Contactor letdown REFINING Rich and lean amine pump spillback Pump spillback/recirculation Various high pressure and low pressure separator letdown

Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher and easy-e are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore

www.Fisher.com
E 1997, 2012 Fisher Controls International LLC. All rights reserved. 8