Transmission Lines
Transmission Lines
Transmission Lines
8.6
Statement for Q.78:
impedance Z o is
(A) 210
. - j17.6 W
(B) 0.05 S m, 1 mF m
(D) 14.0 - j 42 W
(D) 0.2 S m, 1 mF m
(B) 46 106 m s
(C) 23 106 m s
(D) 36 106 m s
(A) 20 W m, 40 mH m
(B) 40 W m, 50 mH m
(C) 40 W m, 40 mH m
(D) 20 W m, 50 mH m
(A) 1.46 m
(B) 3.36 m
(C) 4.39 m
(D) 6.43 m
(A) 96 W
(B) 150 W
(C) 74 W
(D) 105 W
the
following
parameters
(B) 18.5 m
(C) 2.6 m
(D) 0.67 m
(A) 2.46 m
(B) 2.01 m
(C) 1.48 m
(D) 0.24 m
www.nodia.co.in
for
an
Chap 8.6
Transmission Lines
(B) 167 mF m, 0
(D) 221 pF m, 0
(A) added by 4%
(B) removed by 4%
(C) added by 8%
(D) removed by 8%
13.
lossless
line
has
voltage
wave
is
(A) 20 sin ( wt - bz)
Characteristic impedance Z o = 35 + j 49 W ,
-3
-3
(B) 41 + j78 W
(C) 68 + j 46 W
(D) 34 + j23 W
(B) 314
. 108 m s
(C) 20 10 7 m s
(D) 5 10 7 m s
fig. P8.6.2122.
l/6
Zg
(B) 200 W
(C) 100 W
(D) 70 W
Zo = 60 W
Vg
Z L 125 W
~
Fig. P8.6.2122
L = 6.8 mH m,
G = 4.2
(A) 2.08
(B) 1.63
(C) 2.44
(D) 1.93
(A) 23 + j186 W
(B) 46 + j93 W
(A) 36 + j 32.4 W
(B) 18 + j16.2 W
(D) 55 + j 46 W
(C) 35 - j24.8 W
(D) 54 - j26.4 W
(A) 260 ns
(B) 130 ns
(C) 180 ns
(D) 90 ns
www.nodia.co.in
Transmission Lines
Chap 8.6
(A) 126 V
(B) 28.6 V
(C) 21.3 V
(D) 169 V
and
j 40
(C) 0.2 e
j 50
A
A
(B) 0.46 e
j 40
(D) 0.46 e
j 50
(A) 80 W
(B) 51.2 W
(C) 125 W
(D) 45 W
(A) 10
(B) 5
(C) 0
(D) 7.707
correct option
100 m
Zg
Zo = 60 W
Vg
ZL
j40
Zin
Zo = 50 W
Zo = 100 W
Zo = 75 W
5l/8
3l/4
l/2
Z L 60 - j35 W
Fig. P8.6.2629
Fig. P8.6.33
(A) 46 - j 69 W
(B) 39 - j57 W
(C) 67 + j 48 W
(D) 61 + j52 W
Zo = 50 W
Zo1
Zo2
l/4
Fig. P8.6.34
www.nodia.co.in
l/4
75 W
Chap 8.6
Transmission Lines
(A) 28 W
(C) 49 W
(B) 56 W
(D) 24.5 W
(A) 100 W
(B) 50 W
(C) 25 W
(D)
the
transmission
line
shown
in
fig.
l/4
l/4
74 W
Z L 35 - j47.5 W
Zin
S.C.
l
74 W
Fig. P8.6.3940
l/4
39. If Z L = 0 the Z in is
Fig. P8.6.35
(A) 148 W
(B) 106 W
(C) 74 W
(D) 53 W
l/4
100
e1
(A) 39 + j183 W
(B) 39 - j183 W
(C) 64 + j148 W
(D) 64 - j148 W
l/4
e2
40. If Z L = , then Z in is
Line 3 Zo
Zo
Lin
Zo
Li
ZL
l/4
S.C.
S.C.
0
l/1
l/4
Fig. P8.6.41
Fig. P8.6.3638
(B) 25 W
(C)
(D) 50 W
(A) 1 - j1.37
(B) 1 + j1.37
(A) 25 W
(B) 0
(C)
(D) 100 W
transmission line is
www.nodia.co.in
Transmission Lines
Chap 8.6
Solutions
Z L 100 W
l/2
S.C.
l/8
= 0.047 89.27
connected
62.7 17.44
= 36.52 - 35.9
0.047 89.27
G + jwC
= 29.6 - j21.4 W
line
R + jwL
Zo =
Fig. P8.6.42
to
load
impedance
w 2 p 10 7
=
= 46 106 m s
b
1.38
l/4
3. (B) a = 1027
.
Np m = 1027
.
8.686 = 8.92 dB m
200+j150 W
Zin
al = 30 dB
l =
30
= 3.36 m
8.92
4. (B) Vo e - al = 0.2 Vo
ZL
e - al = 0.2
l/8
al = ln 5 = 1.61
1.61
l =
= 18.5 m
0.087
a = 0.087
Fig. P8.6.4344
(B) 0.06l
(C) 0.13l
(D) 0.02l
G=
R
G
=
L
C
R
18 21 10 -12
C=
= 4.2 10 -4 S m
L
9 10 -7
a = RG = 18 4.2 10 -4 = 0.087
(B) 0.13l
(C) 0.53l
(D) 0.86 l
************
p
4
b = 328
.
p
= 0.24 m
4( 3.28)
7. (C) Z o =
l=
R + jwL
G + jwC
= 20
www.nodia.co.in
Chap 8.6
Transmission Lines
G=
R + jwL = 20 + j 40
40
R = 20 W m, L = 6 = 40 mH m
10
Z L - Z o 300 - Z o 1
=
=
Z L + Z o 300 + Z o 2
Z o = 100 W
m
cosh -1
p
d
= 4 10 -7 cosh -1
2 a
pe
.
10 35
=
= 59.4 pF m
.
d
32
cosh -1
cosh -1
2 a
12
.
L=
d=
= 2.69 10
md 4 p 10 -7 0.016
=
= 50.3 nH m
w
0.4
ew e o 40
=
= 221 pF
1.6
d
sw
, s = 0 for air thus G = 0
G=
d
L
d m
md d
12. (C) Z o =
=
=
C
w ew
w e
d
d
= 75 W
Z o = ho = 81 W, Z o =
w ho
w
w = 108
. w
V
13. (B) I ( z, t) = o sin ( wt - bz)
Zo
L
0.2 10 -6
Zo =
=
= 20 W
C
0.5 10 -9
I ( z, t) =
G + jwC
V ( z, t)
= 0.5 sin ( wt - bz)
Zo
14. (D) v =
w 10
=
= 5 10 7 m s
b
2
15. (C) G =
Vo90
1
=
=
Vo+ 180
2
13 + j 85.45
= 109.9 + j915
.
( 4.2 + j 0.13) 10 -3
( R + jwL)( G + jwC)
b = 0.39 rad m, t =
pfms
p5 108 4 p 10 -7 7 10 7
R + jwL
-6
2
2
=
= 26.55 10 -3 W
wdsc 0.4 2.69 10 -6 7 10 7
w 81
=
w 75
Zo =
11. (D) C =
= ( 4.2 + j0.13) 10 -3
17. (A) g =
L
0.66 10 -6
=
= 105 W
C
59.4 10 -12
R=
3.2
= 0.66 mH m
1.2
-9
Zo =
18. (C) Z o =
L
,
C
bl
0.39 8.4
= 260 ns
=
w 2 p 2 106
g = jb = jw LC,
Z ob = wL,
b=
wL 2 p 4.5 10 9 2.6 10 -6
=
= 919 rad m
Zo
80
v=
w Zo
80
=
=
= 30.8 106 m s
b
L 2.6 10 -6
19. (A) G =
s=
Z L - Z o 75 + j25 - 60
=
= 0.212 48.55
Z L + Z o 75 + j25 + 60
1 + |G| 1 + 0.212
=
= 1538
.
1 -|G| 1 - 0.212
sinh gl
cosh gl
Z L - Z o 125 - 60
=
= 0.35
Z L + Z o 125 + 60
1 + |G| 1 + 0.35
=
= 2.08
1 -|G| 1 - 0.35
22. (C) bl =
2p l
= 60
l 6
Z + jZ o tan bl
125 + j 60 tan 60
= 60
Z in = Z o L
Z o + jZ L tan bl
60 + j125 tan 60
= 35 - j24.8
23. (A) G =
www.nodia.co.in
Z L - Z o 210 - 100
=
= 0.355
Z L + Z o 210 + 100
Transmission Lines
SWR s =
1 + |G| 1 + 0.355
=
= 2.1
1 -|G| 1 - 0.355
if
Chap 8.6
tan bl = , Z in =
Z + jZ o tan bl
80 - j 60 + j50
Z in = Z o L
= 50
Z o + jZ L tan bl
50 + 60 + j 80
VL 15 e j 25
=
= 0.2 e - j 5
Z L 75 e j 30
= 21.6 - j203 W
2p
l
, z=
b=
l
4
V = V+ e
+ V- e = V- e
V ( Z = 0) = Vo =
= j10 V,
|V | = 10
V
33. (B) At C, bl =
j 40 + j 60 tan 352.4
= 60
= j29.4
60 - 40 tan 352.4
Z in
Vg
Z in + Z g
= 39 - j57
= (5.75 102 ) e
- j 352 .4
= 5.75 109.6 V
34. (D) bl =
V = VL e
jbl
= (5.75 109.6 ) e
j 57.3
= 5.75 167 V
j 40 + j 60 tan 309.40
= 60
= - j18.2
60 - 40 tan 309.40
V = VL e
jbl
= (5.75 109.6 )( e
30. (B) bl =
j 309.4
) = 5.75 59
2p
p
p
(1.25 l) = + 360 , tan =
l
2
2
Z + jZ o tan bl
Z in = Z o L
Z o + jZ L tan bl
2 p 5l 5 p
= , tan 225 = 1, Z L = Z inB
l 8
4
Z + jZ o
124.4 + j72.5 + j50
= 50
Z in = Z o L
Z o + jZ L
50 + j124.4 - 72.5
VL = Vs ( z = l), Vo = VL e jbl
Z in
tan p = 0
Z o2
100 2
=
= 124.4 + j72.5 W
Z L 60 - j 35
At A, bl =
27. (A) Z in = Z L = j 40 W
VL = Vo e
2p l
= p,
l 2
Z inC = Z L = 60 - j 35 W
2 p 3l 3p
At B, bl =
= , Z L = Z inC = 60 - j 35 W
l 4
4
Z inB =
j29.4
=
10 0 = 5.75 102
j29.4 + 50 - j 40
- jbl
p
= - 38.66 + 90 = 51.34
4
G = 0.468 51.34
q G = q G + 2
But
jp
gz
Z L - Z o 80 - j 60 - 50
=
= 0.468 - 38.66
Z L + Z o 80 - j 60 + 50
32. (D) G =
g = a + jb, V+ = 0, V- = 10 V
- gz
tan bl = 1
2p l
= 45
l 8
25. (A) a = 0 ,
Z o2 80 2
=
= 51.2 W
Z L 125
Z2
2p l p
p
= , tan = , Z in = o ,
ZL
l 4 2
2
Z in 2 =
Z o22
, Z L1 = Z in 2
75
Z in 1 =
Z o21
= Zo
Z L1
35. (A) bl =
Z o21 = Z o Z L1 =
2p l p
= ,
l 4 2
Z in =
50
( 30) 2 = 24.5 W
75
Z o2 50 2
=
= 3378
.
ZL
74
This act as the load to the left line. But there are two
such loads in parallel. Due to the two lines on the right
Z L = 16.9 W,
Z in =
50 2
= 148 W
16.9
2 p l
36. (B) tan bl = tan
=,
l 4
Z in =
Z o2 50 2
=
= 25W
Z L 100
www.nodia.co.in
Chap 8.6
Transmission Lines
37. (C) Z L = 0
2
o
Z
0
Z in =
2 p l
tan bl = tan
=0
l 2
= (open circuit).
(short circuit),
38. (A) Z L = 25 || = 25 W, Z in
Z + jZ o tan bl
Z inL = Z o L
= Z L = 100 W
Z o + jZ L tan bl
50 2
=
= 100 W
25
l
line tan bl =
4
Z + jZ o tan bl
= jZ o = j50 W
Z ins = Z o L
Z o + jZ L tan bl
1
1
1
At junction Y = =
+
= 0.01 - j0.02
Z j50 100
Z o2
100 2
=
= 32 - j24
Z L 200 + j150
l
line, tan bl = 1
8
For
0 + jZ o
= jZ o = j100 W
Z in 2 = Z o
Zo + 0
At the
ZL =
( 32 - j24)( j100)
= 47.06 - j1176
.
32 - j24 + j100
47.06 - j1176
. + j100( -1)
Z in = 100
= 94.11 - j76.45
100 + j( 47.06 - j1176
. )( -1)
l
line
40. (D) If Z L = , at the input end of
8
Z + jZ o
= - jZ o = - j100
= Zo L
Z o + jZ L
z + j tan bl
= L
= j tan bl ,
1 + z L j tan bl
1
tan -1 t,
t 0
d 2p
=
l 1
-1
2 p (p + tan t), t > 0
Z L = 35 - j 47.5, Z o = 50 W, z L =
ZL
= 0.7 - j0.95
Zo
rL = 0.7, xL = -0.95,
1
t=
( -0.95 0.7{0.7(1 - 0.7) 2 + 0.95 2 } ) = 5.93, 0.4
0.7 - 1
d
1
For t = 5.93,
=
tan -1 5.93 = 0.223
l 2p
d
1
For t = 0.4,
=
tan -1 0.4 = 0.06
l 2p
44. (B) bB =
bB =
rL2 t - (1 - xL t)( xL + t)
,
rL + ( xL + t) 2
For t = 5.93,
2
p
b
l
B
=
l 1
-1 1
2 p p + tan b , bB > 0
B
2 p l
yins = - j cot bl = - j cot
= - j1.3764
l 10
yin = z L , z L = 1 + j1.3764,
1
xL rL ( (1 - rL ) 2 + xL2 ) , rL 1
rL - 1
t = tan bd =
xL
, rL = 1
2
7l
line Z in 1 ||Z in 2 will be load.
8
2 p 7 l
tan bl = tan
= -1
l 8
Z in 2
l
= 0.388
l
l
For bB = 0.953,
= 0.13
l
For bB = -118
. ,
Z L = Z o z L = 300 + j 413
www.nodia.co.in
*************