Sinamics G110

Download as pdf or txt
Download as pdf or txt
You are on page 1of 245

Siemens AG 2009

SINAMICS G110, SINAMICS G120 Standard Inverters SINAMICS G110D, SINAMICS G120D Distributed Inverters
Catalog D 11.1 2009

SINAMICS Drives
Answers for industry.

Siemens AG 2009

Related catalogs
SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units E86060-K5511-A101-A4-7600 MICROMASTER Inverters MICROMASTER 420/430/440 0.12 kW to 250 kW E86060-K5151-A121-A6-7600 MICROMASTER/COMBIMASTER MICROMASTER 411 Inverters Distributed Drive Solutions COMBIMASTER 411 E86060-K5251-A131-A2-7600 Low Voltage Motors IEC Squirrel-Cage Motors Frame sizes 56 to 450 D 81.1 DA 51.3 DA 51.2 D 11 Motion Control SIMOTION, SINAMICS S120 and Motors for Productions Machines E86060-K4921-A101-A1-7600 SINAMICS S110 The Basic Positioning Drive PM 22 PM 21

E86060-K4922-A101-A1-7600 SITRAIN Training for Automation and Industrial Solutions E86060-K6850-A101-B9 1) Low-Voltage Controls and Distribution SIRIUS SENTRON SIVACON E86060-K1002-A101-A8-7600 Technical Information incl. LV 1 T LV 1 ITC

E86060-K5581-A111-A3-7600 E86060-K5581-E111-A1-7600 (Supplement) FLENDER Standard Couplings MD 10.1

E86060-K5710-A111-A2-7600 AC NEMA & IEC Motors Further details available on the Internet at: D 81.2 U.S./ Canada

Catalog CA 01 The Offline-Mall of Automation and Drives E86060-D4001-A510-C7-7600 Industry Mall Information and ordering platform in the Internet:

CA 01

http://www.sea.siemens.com/motors MOTOX Geared Motors D 87.1

http://www.siemens.com/automation/mall E86060-K5287-A111-A2-7600 Industrial Communication Part 5: Dezentrale Peripherie SIMATIC ET 200 ET 200S FC Frequency inverters E86060-K6710-A101-B6-7600 IK PI Additional documentation You will find all information material, such as brochures, catalogs, manuals and operating instructions for standard drive systems up-to-date on the Internet at the addresses http://www.siemens.com/sinamics-g110/printmaterial http://www.siemens.com/sinamics-g120/printmaterial http://www.siemens.com/sinamics-g110d/printmaterial http://www.siemens.com/sinamics-g120d/printmaterial You can order the listed documentation or download it in common file formats (PDF, ZIP).
new New products in this catalog.

1)

German

Siemens AG 2009

SINAMICS Drives SINAMICS G110, SINAMICS G120 Standard Inverters SINAMICS G110D, SINAMICS G120D Distributed Inverters
Catalog D 11.1 2009

Introduction The SINAMICS Drive Family The members of the SINAMICS drive family Highlights Safety Integrated Efficient Infeed Technology SINAMICS G110 Standard Inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp) SINAMICS G120 Standard Inverters 0.37 kW to 250 kW (0.5 hp to 400 hp) SINAMICS G110D Distributed Inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp) SINAMICS G120D Distributed Inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp) Tools and Configuration SD Configurator SIZER, STARTER, Drive ES SinaSave Services and Documentation Training, Training Case Documentation Customer Support Appendix Drive converters, Motors, Contact Partners, Online Services,Sales and Delivery Conditions, Export Regulations

1 2 3 4 5 6 7 8 9

The products and systems described in this catalog are manufactured and marketed using a certified quality management system in accordance with DIN EN ISO 9001: 2000 and DIN EN ISO 14001: 2004 (Certificate Registration No. DE-000357 QM UM). The certificate is recognized in all IQNet countries.

Supersedes: Catalog D 11.1 2008 Refer to the Industry Mall for current updates of this catalog: www.siemens.com/automation/mall The products contained in this catalog can also be found in the e-Catalog CA 01. Order No.: E86060-D4001-A510-C7-7600 Please contact your local Siemens branch Siemens AG 2009

Siemens AG 2009

0/2

Siemens D 11.1 2009

Siemens AG 2009

Answers for industry.

Siemens Industry answers the challenges in the manufacturing and the process industry as well as in the building automation business. Our drive and automation solutions based on Totally Integrated Automation (TIA) and Totally Integrated Power (TIP) are employed in all kinds of industry. In the manufacturing and the process industry. In industrial as well as in functional buildings.

Siemens offers automation, drive, and low-voltage switching technology as well as industrial software from standard products up to entire industry solutions. The industry software enables our industry customers to optimize the entire value chain from product design and development through manufacture and sales up to after-sales service. Our electrical and mechanical components offer integrated technologies for the entire drive train from couplings to gear units, from motors to control and drive solutions for all engineering industries. Our technology platform TIP offers robust solutions for power distribution.

The high quality of our products sets industry-wide benchmarks. High environmental aims are part of our eco-management, and we implement these aims consistently. Right from product design, possible effects on the environment are examined. Hence many of our products and systems are RoHS compliant (Restriction of Hazardous Substances). As a matter of course, our production sites are certified according to DIN EN ISO 14001, but to us, environmental protection also means most efficient utilization of valuable resources. The best example are our energy-efficient drives with energy savings up to 60 %.

Check out the opportunities our automation and drive solutions provide. And discover how you can sustainably enhance your competitive edge with us.

Siemens D 11.1 2009

0/3

Siemens AG 2009

ERP Enterprise Resource Planning

Management Level

MES Manufacturing Execution Systems

Operations Level

SIMATIC PCS 7 Process Control (DCS)

Industrial Software for Design and Engineering Installation and Commissioning Operation

Maintenance Modernization and Upgrade Energy Management

Control Level
SIMOTION Motion Control System SINUMERIK Computer Numeric Control

Field Level
PROFIBUS PA Process Instrumentation SIMATIC Sensors

Totally Integrated Automation

HART IO-Link

02.03.2009

Setting standards in productivity and competitiveness.


Totally Integrated Automation. Thanks to Totally Integrated Automation, Siemens is the only provider of an integrated basis for implementation of customized automation solutions in all industries from inbound to outbound.

0/4

Siemens D 11.1 2009

Siemens AG 2009

Ethernet

SIMATIC IT

Ethernet
SIMATIC WinCC SCADA System

Industrial Ethernet Industrial Ethernet

SIMATIC NET Industrial Communication

SIMATIC Controllers Modular/Embedded/ PC-based

SIMATIC HMI Human Machine Interface

Safety Integrated Low-Voltage Controls and Distribution

PROFINET PROFIsafe PROFIsafe SIMATIC Distributed I/O SINAMICS Drive Systems ASIsafe Industrial Ethernet PROFIBUS AS-Interface

Totally Integrated Power


KNX GAMMA instabus

TIA is characterized by its unique continuity. It provides maximum transparency at all levels with reduced interfacing requirements covering the field level, production control level, up to the corporate management level. With TIA you also profit throughout the complete life cycle of your plant starting with the initial planning steps through operation up to modernization, where we offer a high measure of investment security resulting from continuity in the further development of our products and from reducing the number of interfaces to a minimum.

The unique continuity is already a defined characteristic at the development stage of our products and systems. The result: maximum interoperability covering the controller, HMI, drives, up to the process control system. This reduces the complexity of the automation solution in your plant. You will experience this, for example, in the engineering phase of the automation solution in the form of reduced time requirements and cost, or during operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant.

Siemens D 11.1 2009

0/5

Siemens AG 2009

0/6

Siemens D 11.1 2009

Siemens AG 2009

Introduction
1/2 1/2 1/2 1/2 1/3 1/6

1
The SINAMICS drive family Applications Versions Platform concept Quality in accordance with DIN EN ISO 9001 The members of the SINAMICS drive family Low-voltage converters / inverters SINAMICS G110 SINAMICS G120 SINAMICS G110D SINAMICS G120D SINAMICS G130/SINAMICS G150 SINAMICS S110 SINAMICS S120 SINAMICS S150 Medium-voltage drive converters SINAMICS GM150 SINAMICS SM150 SINAMICS GL150 1/6 1/6 1/6 1/6 1/7 1/7 1/7 1/7 1/8 1/8 1/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS
Introduction

The SINAMICS drive family

SINAMICS G

SINAMICS S

Mixer/mills

Metal forming technology Packaging

Extrusion Pumps/fans/ compressors

Rolling mills

Machine tools
G_D211_EN_00137

Textiles Conveyor systems


Application areas of the SINAMICS family

Woodworking

Printing and paper machines

Applications SINAMICS is the new drive family from Siemens for industrial machinery and plant construction. SINAMICS offers solutions for all drive tasks: 7 Simple pump and fan applications in the process industry 7 Demanding single-motor drives in centrifuges, presses, extruders, elevators, as well as conveyor and transport systems 7 Drive line-ups in textile, foil and paper machines as well as in rolling mills 7 Servo drives with a high dynamic performance for machine tools, packaging and printing machines Versions Depending on the application, the SINAMICS family offers the ideal version for each and every drive task. 7 SINAMICS G is designed for standard applications with asynchronous motors. These applications have less stringent demands regarding the dynamic response of the motor speed 7 SINAMICS S handles demanding drive tasks with synchronous and asynchronous motors and fulfills high requirements regarding - the dynamic performance and accuracy - the integration of extensive technological functions in the drive control system

Platform concept and Totally Integrated Automation All of the SINAMICS versions are consequentially based on a platform concept. Common hardware and software components, as well as standardized tools for design, configuration and commissioning tasks, ensure a high level of integration across all components. SINAMICS seamlessly handles the widest range of drive tasks without any system gaps. The different SINAMICS versions can be easily combined with each other. SINAMICS is a part of the Siemens concept Totally Integrated Automation. The degree of integration and standardization of SINAMICS regarding engineering, data management, and communication with the automation level means that solutions with SIMOTION, SINUMERIK and SIMATIC control systems are easy to implement.

1/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS
Introduction
The SINAMICS drive family

SIMOTION

SINUMERIK

SIMATIC

SINAMICS

Synchronous motors

Asynchronous (induction) motors


G_D211_EN_00202

SINAMICS as part of the Siemens modular automation system

Quality in accordance with DIN EN ISO 9001 SINAMICS is able to meet the highest requirements in terms of quality. Comprehensive quality assurance measures in all development and production processes ensure a consistently high level of quality. Of course, our quality assurance system is certified by an independent authority in accordance with DIN EN ISO 9001.

Siemens D 11.1 2009

1/3

Siemens AG 2009

SINAMICS
Introduction

The SINAMICS drive family


Low voltage
For basic applications For high-quality applications For basic servo drives For sophisticated applications

Medium voltage
For high-power applications

SINAMICS G110 V/f Control 0.12 kW ... 3 kW Pumps, fans, conveyor belts

SINAMICS G110D V/f Control/FCC 0.75 kW ... 7.5 kW Conveyor technology

SINAMICS SINAMICS G120 G120D

SINAMICS G130/G150

SINAMICS S110 Servo Control 0.12 kW ... 90 kW Single-axis positioning applications for machine and plant engineering

SINAMICS S120

SINAMICS S150

SINAMICS GM150/SM150/GL150 V/f Control / Vector Control 0.8 MW ... 120 MW Pumps, fans, compressors, mixers, extruders, rolling mills mining hoist drives

V/f Control / Vector Control

V/f Control / Vector Control / Servo Control

0.37 kW ... 250 kW

0.75 kW ... 7.5 kW

75 kW ... 1500 kW

0.12 kW ... 4500 kW Motion Control applications in production machines (packaging, textile, printing, paper, plastic), machine tools, plants and process lines

75 kW ... 1200 kW Test bay drives, cross cutters, centrifuges

Common Engineering Tools


SIZER for simple planning and configuration STARTER for fast commisioning, optimization and diagnostics

1/4

Siemens D 11.1 2009

G_D011_EN_00164b

Pumps, fans, conveyor belts, compressors, mixers, mills, extruders

Siemens AG 2009

SINAMICS
Introduction
The SINAMICS drive family
Tailored to suit different application areas, the SINAMICS range encompasses the following products: Low-voltage converters / inverters (line supply < 1000 V) 7 SINAMICS G110 the versatile drive for low power ratings 7 SINAMICS G120 the modular single-motor drive for low to medium power ratings 7 SINAMICS G110D the distributed, compact single-motor drive in a high degree of protection for basic applications 7 SINAMICS G120D the distributed, modular single-motor drive in a high degree of protection for sophisticated applications 7 SINAMICS G130 and SINAMICS G150 the universal drive solution for high-power single drives 7 SINAMICS S110 the basic positioning drive for single-axis applications 7 SINAMICS S120 the flexible, modular drive system for demanding tasks 7 SINAMICS S150 the drive solution for demanding singlemotor drives with a high power rating Medium-voltage drive converters (line supply > 1000 V) SINAMICS GM150 the universal drive solution for singlemotor drives 7 SINAMICS SM150 the drive solution for demanding single and multi-motor drives 7 SINAMICS GL150 the drive solution for synchronous motors up to 120 MW
7

The SINAMICS family is characterized by the following system properties: Standard functionality based on a platform concept Standardized engineering High degree of flexibility and combinability Wide range of performance and power ratings Designed for global use SINAMICS Safety Integrated A higher level of efficiency and effectiveness Wide range of coupling options to higher-level controls Totally Integrated Automation

Siemens D 11.1 2009

1/5

Siemens AG 2009

SINAMICS
Introduction

The members of the SINAMICS drive family


SINAMICS low-voltage inverters SINAMICS G110 SINAMICS G120 SINAMICS G110D SINAMICS G120D

The versatile drive for low power ratings

The modular single-motor drive for low to medium power ratings

The distributed, compact single-motor drive in a high degree of protection for basic applications

The distributed, modular single-motor drive in a high degree of protection for demanding applications

Main applications Machines and plants in industrial and commercial environments Machines and plants in industrial environments and commercial applications (machinery construction, automotive, textiles, chemicals, printing, steel) Horizontal conveyor system appli- Conveyor-related drive applicacations in the industrial environtions in the industrial environment, ment, main focus on distribution main focus on the automobile inand logistics in airports; generally dustry; also suitable for high-persuitable for basic conveyor-relatformance applications, including ed tasks with local control or conairports and in the food, beverage nected to a bus via AS-Interface and tobacco industry (without tenside) Conveyor systems Airports Distribution logistics Conveyor systems Electric monorail systems in distribution logistics

Application examples Pumps and fans Auxiliary drives Conveyor systems Advertising panels Door or gate drives Centrifuges Highlights Compact Can be flexibly adapted to various applications Simple and fast commissioning Clear terminal layout Optimum interaction with SIMATIC and LOGO! Modular Can be flexibly expanded Simple and fast commissioning Regenerative feedback Innovative cooling concept Optimum interaction with SIMOTION and SIMATIC SINAMICS Safety Integrated Low profile design with standard drilling dimensions (standard footprint) in IP65 degree of protection Simple and fast commissioning Versions with and without a maintenance switch Optional key-operated switch AS-Interface with bus parameterization Quick stop function Integrated brake control, 180 V DC Optimum interaction with SIMATIC and LOGO! Catalog D 11.1 Low profile design with standard drilling dimensions (standard footprint) in IP65 degree of protection Modular Can be flexibly expanded Simple and fast commissioning Regenerative feedback Optimum interaction with SIMOTION and SIMATIC SINAMICS Safety Integrated Pumps and fans Compressors Conveyor systems

Catalog D 11.1

Catalog D 11.1

Catalog D 11.1

1/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS
Introduction
The members of the SINAMICS drive family
SINAMICS low-voltage drive converters SINAMICS G130, SINAMICS G150 SINAMICS S110 SINAMICS S120 SINAMICS S150

The universal drive solution for high-power single drives


Main applications

The basic positioning drive for single-axis applications

The flexible, modular drive system for complex drive tasks

The drive solution for demanding high-power single drives

Plants and machines in the pro Machine and plants in the induscess and production industry, watrial environment, where machine ter/waste, power stations, oil and axes should be quickly and pregas, petrochemicals, raw matericisely positioned in the simplest als for the chemical industry, papossible way. per, cement, stone, steel

Machines and plants in the indus- Machines and plants in the protrial environment (packaging, cess and production industry, plastics, textiles, printing, wood, food, beverage and tobacco, auglass, ceramics, presses, paper, tomotive and steel industry, minlifting equipment, semiconducing/open-cast mining, shipbuildtors, automated assembly and ing, lifting equipment, conveyors testing equipment, handling, machine tools) Motion Control applications (positioning, synchronous operation) Numerical Control, interpolating motion control Converting Technological applications Test stand drives Centrifuges Elevators and cranes Cross cutters and shears Conveyor belts Presses Cable winches

Application examples Pumps and fans Compressors Extruders and mixers Crushers Handling equipment Feed and withdrawal devices Stacking units Automatic assembly machines Laboratory automation Metalworking Woodworking, glass and ceramic industries Printing machines Plastics processing machines For universal use Flexible and modular Scalable in terms of power rating, function, number of axes, performance Simple and fast commissioning, auto-configuration Innovative, futureproof system architecture (Graded infeed/regenerative feedback concepts) Wide range of motors (Optimum interaction with SIMOTION, SIMATIC and SINUMERIK) SINAMICS Safety Integrated Catalog PM 22

Highlights Space-saving Low noise Simple and fast commissioning SINAMICS G130: Modular components SINAMICS G150: Ready-to-connect cabinet unit Optimum interaction with SIMATIC For universal use Flexible and modular Scalable in terms of power rating, function, number of axes, performance Simple and fast commissioning, auto-configuration Innovative, futureproof system architecture Graded infeed/regenerative feedback concepts Wide range of motors Optimum interaction with SIMOTION, SIMATIC and SINUMERIK SINAMICS Safety Integrated Catalogs PM 21 and D 21.3 Four-quadrant operation as standard High control accuracy and dynamic response Almost free of line-current harmonics, considerably lower than the IEEE 519 THD limits Tolerant to fluctuations in the line voltage Reactive power compensation option Simple and fast commissioning Ready-to-connect cabinet unit Optimum interaction with SIMATIC Catalog D 21.3

Catalog D 11

Siemens D 11.1 2009

1/7

Siemens AG 2009

SINAMICS
Introduction

The members of the SINAMICS drive family


SINAMICS medium-voltage drive converters SINAMICS GM150 SINAMICS SM150 SINAMICS GL150

The universal drive solution for singlemotor drives


Main applications Machines and plants in the process industry

The drive solution for demanding single-motor and multi-motor drives

The drive solution for synchronous motors up to 120 MW

Machines and plants, e.g. in the steel and min- Machines and plants in the process industry, ing industry especially in the oil, gas and petrochemicals sectors Rolling mills Mine hoists Test stand drives Conveyor belts Compressors Pumps and fans Extruders and mixers Marine drives Blast furnace blowers Compact design and high power density Easy to operate and monitor Extremely reliable in operation and almost maintenance-free Fully digital Transvector control Two directions of rotation by reversal of rotating field Can be seamlessly integrated into higher-level automation systems

Application examples Pumps and fans Compressors Extruders and mixers Crushers Marine drives Highlights Space-saving Simple and fast commissioning Ready-to-connect cabinet unit Optimum interaction with SIMATIC Four-quadrant operation as standard High efficiency and minimum load on the motor High control accuracy and dynamic response Almost no line harmonics Reactive power compensation option Simple and fast commissioning Ready-to-connect cabinet unit Optimum interaction with SIMATIC Catalog D 12

Catalog D 12

1/8

Siemens D 11.1 2009

Siemens AG 2009

Highlights
2/2 2/2 2/3 2/9 2/9 2/9 2/10 2/10 Safety Integrated Overview Function

2
Efficient Infeed Technology Overview Benefits Applications Additional information

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Overview
Legal framework

Machine manufacturers and plant construction companies must ensure that their machines or plants are not a source of danger due to functional faults as well as general risks relating to electric shock, heat or radiation. In Europe, for example, the EU General Directive stipulates that the Machinery Directive must be maintained for safety at work. In order to ensure compliance with this directive, it is recommended that the corresponding harmonized European standards are applied. This initiates the assumption of conformity and gives manufacturers and operators the legal security in terms of compliance with both national regulations and EU directives. The machine manufacturer uses the CE marking to document the compliance with all relevant directives and regulations in the free movement of goods. Safety-related standards Functional safety is specified in various standards. EN ISO 12100 and EN 1050, for example, are concerned with the construction and risk assessment of machines. EN 62061 (only applicable for electrical and electronic control systems) and EN ISO 13849-1, which will replace the previously used EN 954-1 as from 2009, define the functional and safety-related requirements of control systems with relevance to safety. The integrated safety functions of SINAMICS G120 and SINAMICS G120D provide highly effective application-oriented protection for personnel and machinery. SINAMICS G120 and SINAMICS G120D offer the following Safety Integrated functions (terms as defined in IEC 61800-5-2): Safe Torque Off (STO) Safe Stop 1 (SS1) Safely Limited Speed (SLS) Safe Brake Control (SBC) (SINAMICS G120 only) The Safety Integrated functions are completely integrated into the drive system. They can be activated as follows: via safe digital inputs on the Control Unit (SINAMICS G120 only) without the need for an additional safety relay via PROFIBUS with PROFIsafe via PROFINET with PROFIsafe The Safety Integrated functions are implemented electronically and therefore offer short response times in comparison to solutions with externally implemented monitoring functions. This system is absolutely unique worldwide in that it does not require speed feedback through sensors or encoders. The STO and SBC functions can be used without restriction for all applications. The SS1 and SLS functions may be used for any application in which the load can never accelerate when the frequency inverter is switched off. Therefore, they are not suitable for applications with loads that can pull, e.g. lifting gear and winders. The above-mentioned standards define different safety requirements that the machine has to satisfy in accordance with the risk, the frequency of a dangerous situation, the probability of occurrence and the opportunities for recognizing impending danger: EN 954-1: Categories B, 1 4 EN ISO 13849-1: Performance Level PL a e EN 62061: Safety Integrity Level SIL 1 3 Trend toward integrated safety systems The trend toward greater complexity and increasing modularity of machines has seen a shift in safety functions away from the classical central safety functions (for example, shutdown of all drives by a line contactor) and into the machine control system and the drives. One advantage of this development is that some safety-related circuitry involving complex hardware is now no longer necessary. Integrated safety functions act much faster than those of a conventional design. As a consequence, the safety of a machine is increased further with Safety Integrated. Furthermore, safety measures controlled by integrated safety systems are perceived as less interfering by the operator of the machine due to the faster action, so the motivation to consciously bypass safety functions is significantly reduced.

2/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Function
Safety functions integrated in the SINAMICS G120 and SINAMICS G120D drive systems SINAMICS G120 and SINAMICS G120D are characterized by a large number of integrated safety functions. The inverters fulfill the equipment requirements of Category 3 according to EN 954-1 Safety Integrity Level (SIL) 2 according to EN 61508 The Safety Integrated functions provided by SINAMICS G120 and SINAMICS G120D have been certified by independent institutes. You can obtain the corresponding external test certificates and manufacturer's declarations from your Siemens contact person for SINAMICS G120 under: http://www.siemens.com/sinamics-g120/certificates for SINAMICS G120D under: http://www.siemens.com/sinamics-g120d/certificates The Safety Integrated functions currently available in SINAMICS G120 and SINAMICS G120D are listed below (functions and designations as defined in IEC 61800-5-2): Safe Torque Off (STO) Function description This function is a mechanism that prevents the drive from restarting unexpectedly, in accordance with EN 60204-1, Section 5.4. Safe Torque Off cancels the drive pulses and disconnects the power supply to the motor (corresponds to Stop Category 0 acc. to EN 60204-1). The drive is reliably torque-free. This state is monitored internally in the drive. Application, customer benefits STO has the immediate effect that the drive cannot provide any torque-generating energy. STO can be used wherever the drive will reach a standstill autonomously due to the load torque or friction in a sufficiently short time or when the drive can safely coast down.
t v

Safe Stop 1 (SS1) Function description The Safe Stop 1 function can safely stop the drive in accordance with EN 60204-1, Stop Category 1. When the SS1 function is selected, the drive brakes autonomously along an adjustable, monitored ramp and automatically activates the Safe Torque Off and Safe Brake Control functions (if used) when 2 Hz is reached. If the drive does not brake along the parameterized ramp when the stop function is activated, Safe Torque Off and Safe Brake Control (if used) are activated instantaneously. Application, customer benefits This integrated fast-brake function eliminates the need for complex external monitoring equipment. Furthermore, it is often possible to eliminate mechanical brakes which wear, or to lessen the load on them, so that maintenance costs and the stresses on the machine can be reduced. Safe Stop 1 is employed for applications which require monitored braking, e.g. on centrifuges, conveyor vehicles, etc.

STO
G_D011_XX_00169

STO
G_D211_XX_00210

Siemens D 11.1 2009

2/3

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Function
Safely Limited Speed (SLS) Function description Safe Brake Control (SBC) Function description Safe Brake Control SBC is used to control holding brakes which are operative at zero current, e.g. motor brakes. The brake control circuit is a fail-safe, two-channel design. The Safe Brake Control is activated when the Safe Torque Off function is selected and when safety monitors respond with safe pulse cancellation. This function is available only for the SINAMICS G120 system. It requires an additional Safe Brake Relay. Safe Brake Control does not detect mechanical faults in the brake itself, such as worn brake linings. The Safe Brake Relay is only capable of controlling 24 V motor brakes. Application, customer benefits SBC can also be activated in combination with STO and SS1. SBC provides the option of safely controlling a motor brake on the motor when the torque-generating energy has been disconnected. As the Safe Brake Control module does not contain any mechanical components, there are no restrictions on the switching frequency.
Safe Brake Relay
G_D011_XX_00170

The Safely Limited Speed function safely monitors the drive and, depending on the mode selected, either limits the motor speed to a safe value or monitors the system directly for a parameterized maximum speed. If the drive does not follow the parameterized ramp or exceeds the maximum speed when the function is activated, it is either braked along the Safe Stop 1 ramp or Safe Torque Off and Safe Brake Control (if used) are activated (depending on which mode is selected). Application, customer benefits When many machines are being set up, the operating personnel must work on the moving machine. This either occurs in stages because the operator must exit the danger area repeatedly when the machine is started up, or the operator works on the moving machine and is therefore exposed to increased risk. The SLS function can save a considerable amount of time here and still increase the safety of operating personnel.

SLS

P24

Motor holding brake

M
B-

New functions from firmware V3.2 and higher With firmware V3.2, the existing safety functions have been expanded as follows: Starting the motor with activated SLS Reversing operation with activated SLS Improved use of PROFIsafe feedback signals. The actual status of the safety functions is signaled to the F-CPU using the feedback signals The replacement of a fail-safe inverter has been significantly simplified as the operator no longer has to make any parameter changes

2/4

Siemens D 11.1 2009

G_D211_EN_00215

Brake diagnostics

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Function
PROFIsafe PROFIsafe is an open communications standard that supports standard and safety-related communication over the same communications cable (hard-wired or wireless). A second, separate bus system is therefore not necessary. To ensure safe communication, the transmitted telegrams are continuously monitored. Possible errors, such as lost or repeated telegrams or those received in the wrong order are avoided in that safety-related telegrams are numbered consecutively, their reception is monitored within a defined period, and an identifier for the sender and receiver of a telegram is transferred. A CRC (cyclic redundancy check) data security mechanism is also used. PROFIsafe can be implemented on PROFIBUS and PROFINET for the SINAMICS G120 and SINAMICS G120D systems.
Function Activation Underlying function Response when a limit value is exceeded External setpoint input effective no no Encoder required

Licensing The Safety Integrated functions for SINAMICS G120 and SINAMICS G120D do not require a license. The availability of Safety Integrated functions depends on the type of Control Unit, i.e. whether it is a standard Control Unit or a Fail-safe Control Unit. An overview of the Safety Integrated functions of SINAMICS G120 and SINAMICS G120D with their secondary conditions is given in the following table:

STO SS1

PROFIsafe over PROFIBUS or PROFINET Fail-safe digital inputs (with SINAMICS G120 only) PROFIsafe over PROFIBUS or PROFINET Fail-safe digital inputs (with SINAMICS G120 only) PROFIsafe over PROFIBUS or PROFINET Fail-safe digital inputs (with SINAMICS G120 only)

SBC (if parameterized)

no no

STO when 2 Hz is Activation of STO reached, followed Activation of SBC by SBC (if parame- (if parameterized) terized) Activation of STO or SS1 Activation of SBC (if parameterized)

SLS

yes (depending on mode)

no

SBC (only with SINAMICS G120)

With STO With SS1 when 2 Hz is reached

no

The operating principle of Safety Integrated Two independent switch-off signal paths Two independent switch-off signal paths are available. All switch-off signal paths are low active. Thereby ensuring that the system is always switched to a safe state if a component fails or in the event of an open circuit. If an error is discovered in the switch-off signal paths, the Safe Torque Off function is activated and a system restart inhibited. Two-channel monitoring structure All the main hardware and software functions for Safety Integrated are implemented in two independent monitoring channels (e.g. switch-off signal paths, data management, data comparison). A cyclic crosswise comparison of the safety-relevant data in the two monitoring channels is carried out. The monitoring functions in each monitoring channel work on the principle that a defined status must prevail before each action is carried out and a specific acknowledgement must be made after each action. If this expectation is not fulfilled in a monitoring channel, the drive is stopped through two channels and an appropriate message is output. Forced dormant error detection using a test stop The functions and switch-off signal paths must be tested at least once within a defined time in order to meet requirements as per EN 954-1 and IEC 61508 in terms of timely fault detection. This functionality must be implemented by initiating a test stop, either manually at regular intervals (cyclically) or using an automated process. The test stop cycle is monitored and an alarm is output following a timeout. A test stop does not require Power On. The acknowledgment is set by canceling the test stop request. When the appropriate safety devices are implemented (e.g. guard doors), it can be assumed that running machinery will not pose any risk to personnel. For this reason, only an alarm is output to inform the user that a forced dormant error detection run is due, thereby requesting that this be carried out at the next available opportunity. Examples of when forced dormant error detection must be performed: When the drives are at a standstill after the system has been switched on Before the guard door is opened At defined intervals (e.g. every 8 hours) In the automatic mode, time- and event-driven

Siemens D 11.1 2009

2/5

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Function
STO function architecture for SINAMICS G120 and SINAMICS G120D

Fail-safe Control Unit

Power Module
Supply
Channel A Channel B Switch-off signal path A

&

PROFIBUS PROFINET

PROFIsafe Channel A

Processor 1

Feedback

Actual frequency acquisition M

Cross-check

Channel A Feedback A

Fail-safe digital inputs (for SINAMICS G120 only)

Processor 2
Channel B Feedback Channel B

Switch-off signal path B Feedback B

Processor 3

Channel A

Brake control

Channel B

Feedback

Safe Brake Module

Channel A to the brake Channel B


G_D011_EN_00171

SS1 and SLS function architecture for SINAMICS G120 and SINAMICS G120D

Fail-safe Control Unit

Power Module
Supply
Channel A Channel B Switch-off signal path A

&

PROFIBUS PROFINET

PROFIsafe Channel A

Processor 1

Feedback

Actual frequency acquisition M

Cross-check

Channel A Feedback A

Fail-safe digital inputs (for SINAMICS G120 only)

Processor 2
Frequency setpoint Channel B Feedback Channel B Channel A Feedback B

Processor 3

Brake Control

Channel B

Feedback

Safe Brake Module

Channel A to the brake Channel B


G_D011_EN_00172

2/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Function
Comparison between conventional and integrated safety systems To implement safety functions in conjunction with drives, in some cases complex and costly solutions are required. These costs are significantly reduced using the safety functions integrated in SINAMICS G120 and SINAMICS G120D. Safe Torque Off (STO)
L+ (24 V DC)

2
Safe Stop 1 (SS1)
L+ (24 V DC)

K1 ON K2

K1 K2
A1 Y10 Y11 Y12 Y21 Y22 13 23 31 47 57

K1 K2 AUS3 Frequency inverter


Y33 Y34 PE A2 14 24 32 48 58

A1 Y1 Y2 13 23 33

Frequency inverter

41 42 A2 14 24 34

K2 M ON K1 M
G_D011_EN_00176

K1

K2

K1 M
G_D011_EN_00173

K2

Conventional wiring

Conventional wiring

G_D011_EN_00174

G_D011_EN_00177

SINAMICS G120
L1L2 L3 U2V2 W2 60 61 9 L1L2 L3

SINAMICS G120
U2V2 W2 60 61 9

STO

Details

SS1
STO

Details

SS1

380 ... 480 V 3 AC

380 ... 480 V 3 AC

Integrated safety via fail-safe inputs


F-CPU with F-DI

Integrated safety via fail-safe inputs


F-CPU with F-DI

G_D011_EN_00175

G_D011_EN_00178

STO

SS1

PROFIBUS with PROFIsafe or PROFINET with PROFIsafe

PROFIBUS with PROFIsafe or PROFINET with PROFIsafe

Integrated safety via PROFIsafe

Integrated safety via PROFIsafe

Siemens D 11.1 2009

2/7

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Safety Integrated

Function
Safely Limited Speed (SLS)

L+ (24 V DC) Activation of speed monitoring K1 K2 Safe speed monitor

K1 ON K2

Frequency inverter

A1 Y1 Y2 13 23 33

II

41 42 A2 14 24 34

Speed acquisition

K1 M
G_D011_EN_00179

K2

Shaft breakage detection

Conventional wiring

G_D011_EN_00180

SINAMICS G120
L1L2 L3 U2V2 W2 60 61 62 63 9

SS1 SLS

Details

380 ... 480 V 3 AC

SS1

SLS

Integrated safety via fail-safe inputs

F-CPU with F-DI

SLS SS1
G_D011_EN_00181

PROFIBUS with PROFIsafe or PROFINET with PROFIsafe

Integrated safety via PROFIsafe

2/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Efficient Infeed Technology

Overview
Siemens is setting a completely unique new global standard in the field of compact inverters: The technology applied is a world first and provides regenerative feedback capability in smaller, lighter and much lower-cost inverter units. Available inverters with Efficient Infeed Technology The following inverters are equipped with Efficient Infeed Technology: SINAMICS G120 (integrated in PM250 and PM260 Power Modules) SINAMICS G120D SIMATIC ET 200S FC SIMATIC ET 200pro FC SINAMICS G120 and SINAMICS G120D are listed in this catalog (Parts 4 and 6). You can find information on the two SIMATIC ET 200 drive converters in Part 9 and in the Catalog IK PI. Potential savings thanks to Efficient Infeed Technology The table below shows the advantages of the technology as compared to conventional 2-quadrant inverters.
Standard Technology Line reactor Required Efficient Infeed Technology Not required

Three technical criteria are of particular significance: Regenerative feedback - 100 % braking power is fed back, allowing continuous braking. This is not possible in practice using braking resistors - A braking resistor does not need to be configured - No need for installation, cooling monitoring, etc. for external components Minimal reactive power distortion - The current consumption does not manifest any spikes but is almost like a block, therefore a minimum transformer throughput rating is required and reduced reactive power distortion - In order to achieve such a low harmonic content (line harmonics) for an inverter with a conventional DC link, a line reactor with a uK = 6 % is required - Results in approx. 22 % lower current consumption, which corresponds to approximately 40 % lower losses in the supply system - The load on the power supply system is therefore reduced Reactive power compensation, improved cos - Slightly capacitive behavior at the input 0.94 - Compensates the reactive power of motors and other inductive loads on the same supply - The current required for the entire system is reduced. In a system comprising one inverter with motor and another motor on the same supply, the total current consumption is reduced by up to 12 %. Line supply conditions Inverters with Efficient Infeed Technology have a much lower harmonic content (and therefore lower reactive current component) than a standard frequency inverter. The harmonics up to and including the 11th are significantly lower than specified in the relevant standard. These relevant harmonics are less than half the magnitude stipulated by the relevant standard (EN 61000-3-12). The requirements on the line supply are no more stringent than for comparable standard inverters. Experience has proven that this technology can be applied worldwide. Sole exception: In island networks with a separate generator (without a line supply), an external capacitor must be used to reduce resonance effects. This must be dimensioned according to the particular system. Permissible ratio between the line supply short-circuit power SK_line and the inverter apparent power Sinverter:

Braking resistor

Required

Not required

Configuration overhead

Standard

Low

Generated harmonics

Standard

Minimal

Heat generated when braking

Yes

No

SK_line 100 Sinverter corresponding to uK 1 %

Benefits
7

Power infeed

Standard

Approx. 22% less

7 7

Power consumption

Standard

Approx. 22% less

7 7

Energy efficiency

Standard

Good

7 7 7

Reactive power compensation

No

Yes

Continuous braking with 100 % rated power Energy savings through regenerative feedback with the motor operating in generator mode The braking resistor, line reactor and brake chopper can be eliminated No costly configuration of the braking resistors and no costly cabling Requires considerably less space than a conventional compact inverter Up to 22 % lower power infeed No additional heat generated when braking Cost saving Space saving

Installation outlay

Standard

Low

G_D011_EN_00182

Siemens D 11.1 2009

2/9

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Efficient Infeed Technology

Applications

SINAMICS infeed concepts SINAMICS offers four design concepts for the inverter infeed circuit.
Concept Basic Infeed Characteristic features No regenerative feedback capability Braking resistor required for braking operation High harmonic content (reactor available as option) Regenerative feedback capability Line reactor is essential Efficiency, approx. 96 % to 97 % Regenerative feedback capability Line reactor not required/not permitted Efficiency, approx. 98 % High energy efficiency and active current component Low harmonic component Regenerative feedback capability Sinusoidal current when motoring and generating High DC link voltage, line supply fluctuations can be compensated

Whenever an application involves movements with frequent changes in speed or rotational direction or requires masses to be electrically braked, inverters with regenerative feedback capability are an attractive drive solution for both operating companies and machine manufacturers. This is true in part for applications with vertical motion in general or for driven loads with a high moment of inertia: Drives for conveyor vehicles Stage machinery in theaters Cranes Heavy load transport systems/conveyors Storage and retrieval machines Centrifuges Renewable energy sources (hydro-electric power, wind power) Brake testing systems Drum-type crushers/revolving screens Vertical load hoists Industrial washing machines Shuttles/elevator systems/endless bucket belts Rolling mills/conveyor belts Winding machines Generally, for applications with a high braking power over long periods of time, in many cases it makes sense to use Efficient Infeed Technology this reduces the costs and the amount of space required.

Smart Infeed

Efficient Infeed

Active Infeed

Additional information
Capacitive reactive currents For the PM250 Power Modules that are capable of energy recovery with integrated class A EMC filter and PM250D, as a result of the topology, the capacitance that is effective at the inverter input is greater than that for conventional PM240 Power Modules. This results in higher capacitive reactive currents as soon as voltage is connected to the Power Module. The capacitive reactive current only has to be taken into consideration when determining the cable cross-section and infeed point for group drives with a low coincidence factor.
Rated power of the PM250 Power Module for low overload LO kW 7.5 11 15 hp 10 15 20 Filter capacitance 50-Hz impedance Current at 400 V 60-Hz impedance Current at 480 V

The following inverters are equipped with Basic Infeed: SINAMICS G110 SINAMICS G120 (integrated in Power Modules PM240) SINAMICS G110D These inverters are equipped with Efficient Infeed: SINAMICS G120 (integrated in PM250 and PM260 Power Modules) SINAMICS G120D For information on SINAMICS products with Smart Infeed and Active Infeed, refer to Catalogs D 11, PM 21 and PM 22.

Values apply to PM250 Power Modules with integrated class A line filter F 42.4 42.4 42.4

A 3.08 3.08 3.08 Current at 400 V

A 4.43 4.43 4.43 Current at 480 V

75.1 75.1 75.1 50-Hz impedance

62.6 62.6 62.6 60-Hz impedance

Rated power Filter of the capaciPM250D tance Power Module for high overload HO kW 0.75 1.5 3.0 4.0 5.5 7.5 hp 1.0 2.0 4.0 5.4 7.5 10 F 8.9 8.9 32.4 32.4 42.4 42.4

A 0.65 0.65 2.35 2.35 3.08 3.08

A 0.93 0.93 3.38 3.38 4.43 4.43

357.7 357.7 98.2 98.2 75.1 75.1

298.0 298.0 81.9 81.9 62.6 62.6

In case of questions, please contact: [email protected]

2/10

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Efficient Infeed Technology

Additional information
Example of an application with a hoist drive of a stacker crane The following example shows the total cost calculation for a hoist drive of a stacker crane. A generally available compact inverter without regenerative feedback is compared to an inverter with Efficient Infeed Technology (e.g. SINAMICS G120 with PM250 and regenerative feedback). The engineering and installation costs must still be considered separately. This results in additional savings in time and costs by using Efficient Infeed Technology.
Price example Space requirement (equipment only) Euro cm3 35035

This application example is based on the following data: Hoist drive (technical specifications) mtotal = 1900 kg mload = 1000 kg mintrinsic = 900 kg vhoist = 60 m/min = 1 m/s astarting/braking = 0.5 m/s2 (tstarting/braking = 2 s) total = 0.85 Total height = 24 m Hoisting height = 18 m Motor (technical specifications): Prated = 11.0 kW (14.8 hp) n50 Hz = 1460 rpm nmax = 2980 rpm (102 Hz) Mrated = 71.9 Nm = 0.89 Irated = 37.2 A (at 230 V) 87-Hz-characteristic Gear unit (technical specifications): Helical bevel gear unit with i = 40.5 = 0.96

Standard technology
Standard inverter without PROFIBUS or encoder without regenerative feedback, 22 kW high overload Braking resistor (2 in series, 2 in parallel) Line reactor Energy costs 1) Total 2900.

1504. 253. 8850. 13507. 3600. 225. 4220. 8045. 40 % cost saving

80100 12155 127290 29610

Efficient Infeed Technology


SINAMICS G120 with PM250 and CU240E with regenerative feedback, 22 kW high overload Energy costs 1) Total

29610 77 % space saving

1)

For a total service life of 12500 h, FEM 9.512 calculation basis for stacker cranes.

Siemens D 11.1 2009

2/11

Siemens AG 2009

SINAMICS G120, SINAMICS G120D


Highlights
Notes

2/12

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110 Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)


3/2 3/2 3/2 3/3 3/3 3/3 3/4 3/4 3/5 3/9 3/10 3/11 3/12 3/12 3/12 3/13 3/13 3/13 3/14

SINAMICS G110 standard inverters Overview Benefits Applications Design Function Controlled Power Modules Selection and ordering data Technical specifications Accessories Dimensional drawings Circuit diagrams Starter Kit Overview Selection and ordering data Line-side power components Overview Technical specifications Selection and ordering data

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
SINAMICS G110 standard inverters

Overview

Benefits
7 7 7 7 7 7

3
SINAMICS G110, frame size FSA (right with flat heat sink)

7 7 7 7 7 7 7 7 7 7

SINAMICS G110, frame sizes FSB and FSC

7 7

SINAMICS G110 is a frequency inverter with basic functions for a wide range of industrial drive applications with variable speeds. The extremely compact SINAMICS G110 inverter operates with voltage-frequency control at 200 V to 240 V on single-phase line supply systems. It is the ideal price-conscious frequency inverter solution in the lower power range of the SINAMICS product family. The following line-side power components are available for SINAMICS G110 inverters: EMC filter Line reactors Fuses Circuit breaker The accessories listed below are also available: Operator panel Mounting accessories Commissioning tool The latest technical documentation (catalogs, dimensional drawings, certificates, manuals and operating instructions), are available on the Internet under: http://www.siemens.com/sinamics-g110/documentation and offline on the DVD CA 01 in the SD Configurator. In addition, the SD Configurator can be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com/dt-configurator

Simple installation, parameterization and commissioning Robust EMC design Extensive parameter range enables configurations for a wide range of applications Simple cable connection Scaleable functionality with analog and USS versions Quiet motor operation as a result of the high pulse frequency Status information and alarms via the optional BOP (Basic Operator Panel) Rapid copying of parameters via the optional BOP External options for PC communication and BOP Fast response time of the digital inputs with a high degree of reproducibility for applications demanding fast responses Precise setpoint input using a high-resolution 10-bit analog input (analog versions only) LED for status information Versions with integrated EMC filter, class A or B DIP switches for easy adaptation to 50 Hz or 60 Hz applications DIP switches for simple bus termination for the USS version (RS 485) Bus-capable serial RS485 interface (USS versions only) enables integration into a networked drive system 2/3-wire method (static/pulsed signals) for universal control via digital inputs Adjustable lower voltage limit in DC link to ensure controlled motor braking if the power fails

Accessories (overview) BOP operator panel Adapter for mounting on DIN rails (frame sizes FSA and FSB) PC Inverter Connection Kit STARTER commissioning tool Line-side power components (overview) EMC filter, class B with low leakage currents (additionally available for inverters with integrated filter) EMC filter, class B (additionally available for inverters with integrated filter) Line reactors International standards Fulfills the requirements of the EU Low-Voltage Directive CE mark Certified to UL and cUL c-tick

3/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
SINAMICS G110 standard inverters

Applications
The SINAMICS G110 inverter is especially suited for applications with pumps and fans, as a drive in various sectors, e.g. food and beverages, textiles, packaging, as well as conveyor technology, with factory gate and garage door drives and as a universal drive for moving advertising media.

Function
The stress on the machine mechanical system is reduced by using a skippable frequency range to avoid resonance effects, parameterizable ramp-up/ramp-down times up to 650 s, ramp rounding-off as well as being able to switch the inverter to a spinning motor (flying restart circuit) Increased plant availability as a result of automatic restarting following a power failure or stoppage Fast current limiting (FCL) for fault-free operation in the event of sudden load surges Parameterizable V/f characteristic (e.g. for synchronous motors) DC braking as well as compound braking for fast braking without an external braking resistor DC link voltage limiting using VDCmax controller Slip compensation, electronic motorized potentiometer function and three fixed speed setpoints Parameterizable voltage boost for a higher dynamic performance when starting and accelerating Motor holding brake function to control an external mechanical brake

Design
The SINAMICS G110 standard inverters include a control and power module and for inverters in the CPM 110 version (Controlled Power Module) results in a compact and efficient design. They operate with the latest IGBT technology and digital microprocessor control. The SINAMICS G110 inverter product range consists of the following versions: The analog type is available in the following versions: - without EMC filter, with heat sink - integrated EMC filter, class A/B, with heat sink - without EMC filter, with flat heat sink (frame size FSA only) - integrated EMC filter, class B, with flat heat sink (frame size FSA only) The USS type (RS485) is available in the following versions: - without EMC filter, with heat sink - integrated EMC filter, class A/B, with heat sink - without EMC filter, with flat heat sink (frame size FSA only) - integrated EMC filter, class B, with flat heat sink (frame size FSA only) From frame size FSA, cooling is achieved through a heat sink and natural convection. Frame size FSA with flat heat sink offers space-saving and favorable heat dissipation since an additional heat sink can be installed outside the control cabinet. For frame sizes FSB and FSC, an integrated fan is used to cool the heat sink which has resulted in the compact design. For all of the inverter versions, the connections are easy to access and they all have the same standard position. To ensure optimum electromagnetic compatibility and easy connection, the line and motor connections are separated and located on opposite sides (the same as for contactors). The control terminal block has screwless terminals. The optional BOP (Basic Operator Panel) can be installed without the use of tools.

Siemens D 11.1 2009

3/3

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Selection and ordering data


With reference to the rated output current, the modules support at least 2-pole to 6-pole low-voltage motors, e.g. the new 1LE1 motor series (please refer to the Appendix for further information).
Power Rated input current (at 230 V) Rated output current Frame Version size

The rated power is merely a guide value. For a description of the overload performance, please refer to the general technical specifications of the Controlled Power Modules.
SINAMICS G110 without filter SINAMICS G110 with integrated filter

3
kW 0.12 hp 0.16 A 2.3 A 0.9 FSA Analog USS Analog (with flat heat sink) USS (with flat heat sink) 0.25 0.33 4.5 1.7 FSA Analog USS Analog (with flat heat sink) USS (with flat heat sink) 0.37 0.5 6.2 2.3 FSA Analog USS Analog (with flat heat sink) USS (with flat heat sink) 0.55 0.75 7.7 3.2 FSA Analog USS Analog (with flat heat sink) USS (with flat heat sink) 0.75 1.0 10.0 3.9 (at 40 C) FSA Analog USS Analog (with flat heat sink) USS (with flat heat sink) 1.1 1.5 2.2 3.0 1.5 2.0 3.0 4.0 14.7 19.7 27.2 35.6 6.0 7.8 (at 40 C) 11.0 13.6 (at 40 C) FSB FSB FSC FSC Analog USS Analog USS Analog USS Analog USS Order No. 6SL3211-0AB11-2UA1 6SL3211-0AB11-2UB1 6SL3211-0KB11-2UA1 6SL3211-0KB11-2UB1 6SL3211-0AB12-5UA1 6SL3211-0AB12-5UB1 6SL3211-0KB12-5UA1 6SL3211-0KB12-5UB1 6SL3211-0AB13-7UA1 6SL3211-0AB13-7UB1 6SL3211-0KB13-7UA1 6SL3211-0KB13-7UB1 6SL3211-0AB15-5UA1 6SL3211-0AB15-5UB1 6SL3211-0KB15-5UA1 6SL3211-0KB15-5UB1 6SL3211-0AB17-5UA1 6SL3211-0AB17-5UB1 6SL3211-0KB17-5UA1 6SL3211-0KB17-5UB1 6SL3211-0AB21-1UA1 6SL3211-0AB21-1UB1 6SL3211-0AB21-5UA1 6SL3211-0AB21-5UB1 6SL3211-0AB22-2UA1 6SL3211-0AB22-2UB1 6SL3211-0AB23-0UA1 6SL3211-0AB23-0UB1 Order No.

Filter class 1) when using shielded cables with a max. cable length of 5m 10 m 25 m A 2) A
2) 2) 2) 2)

6SL3211-0AB11-2BA1 B 6SL3211-0AB11-2BB1 B 6SL3211-0KB11-2BA1 B 6SL3211-0KB11-2BB1 B 6SL3211-0AB12-5BA1 B 6SL3211-0AB12-5BB1 B 6SL3211-0KB12-5BA1 B 6SL3211-0KB12-5BB1 B 6SL3211-0AB13-7BA1 B 6SL3211-0AB13-7BB1 B 6SL3211-0KB13-7BA1 B 6SL3211-0KB13-7BB1 B 6SL3211-0AB15-5BA1 B 6SL3211-0AB15-5BB1 B 6SL3211-0KB15-5BA1 B 6SL3211-0KB15-5BB1 B 6SL3211-0AB17-5BA1 B 6SL3211-0AB17-5BB1 B 6SL3211-0KB17-5BA1 B 6SL3211-0KB17-5BB1 B 6SL3211-0AB21-1AA1 B 6SL3211-0AB21-1AB1 B 6SL3211-0AB21-5AA1 B 6SL3211-0AB21-5AB1 B 6SL3211-0AB22-2AA1 B 6SL3211-0AB22-2AB1 B 6SL3211-0AB23-0AA1 B 6SL3211-0AB23-0AB1 B

A 2) A 2) A 2) A A
2) 2)

2)

2) 2) 2)

A 2) A 2) A 2) A
2)

2)

2) 2) 2)

A 2) A 2) A
2)

2)

2) 2) 2)

A 2) A 2) A 2) A A
2) 2)

2)

2) 2) 2)

A 2) A 2) A 2) A A A A A
2) 2) 2) 2) 2)

2)

A 2) A 2) A 2) A 2) A 2) A 2) A 2) A 2)

A 2)

The current data apply to an ambient temperature of 50 C unless specified otherwise. The last digit of the complete order number for the SINAMICS G110 inverters represents the release version. When ordering, a different digit from the one specified may be present as a result of further technical development.
1)

All SINAMICS G110 inverters are supplied without an operator panel (BOP). A BOP or other accessories must be ordered separately.

The filter class in bold is stamped on the inverter rating plate.

2)

Class B also with additional filter.

3/4

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Technical specifications
Controlled Power Modules Power range Line voltage Line supply frequency Output frequency cos Inverter efficiency for units < 0.75 kW (1.0 hp) for units 0.75 kW (1.0 hp) Overload capability 0.12 3.0 kW (0.16 ... 4.0 hp) 200 240 V 1 AC 10 % 47 63 Hz 0 650 Hz 0.95 90 94 % 95 % Overload current 1.5 rated output current (i.e. 150 % overload) for 60 s, then 0.85 rated output current for 240 s, cycle time 300 s Not higher than the rated input current Linear V/f characteristic (with parameterizable voltage boost); square V/f characteristic; multipoint characteristic (parameterizable V/f characteristic) 8 kHz (standard) 2 16 kHz (in 2-kHz increments) 3, parameterizable 1, parameterizable 0.01 Hz digital 0.01 Hz serial 10 bit analog (motorized potentiometer 0.1 Hz) 3 parameterizable digital inputs, non-isolated, PNP, SIMATIC-compatible 1, for setpoint (0 ... 10 V, scalable or can be used as 4th digital input) 1 isolated optocoupler output (24 V DC, 50 mA, ohmic, NPN type) RS485, for operation with USS protocol 25 m 50 m All devices with integrated EMC filter for drive systems in category C2 installations (limit value in accordance with EN 55011, class A, group 1) and category C3 installations (limit value in accordance with EN 55011, class A, group 2). All devices with an integrated EMC filter and shielded cables with a maximum length of 5 m also fulfill the limit values of EN 55011, class B for conducted interference. DC braking, compound braking IP20 10 +40 C to +50 C with derating 40 +70 C 95 % (condensation not permissible) Up to 1000 m above sea level without power reduction Rated output current at 4000 m above sea level: 90 % Line supply voltage up to 2000 m above sea level: 100 % at 4000 m above sea level: 75 % 10 kA Undervoltage Overvoltage Ground fault Short circuit Stall protection Thermal motor protection I2t Inverter overtemperature Motor overtemperature UL, cUL, CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC

Pre-charging current Control methods

Pulse frequency Fixed frequencies Skippable frequency range Setpoint resolution

Digital inputs Analog input (analog version) Digital output Serial interface (USS version) Motor cable length, max. Shielded Unshielded Electromagnetic compatibility

Braking Degree of protection Operating temperature Storage temperature Relative humidity Installation altitude

Standard SCCR (Short Circuit Current Rating) 1) Protection features for

Compliance with standards CE mark


1)

Applies to industrial control cabinet installations to NEC Article 409/UL 508A. For further information, visit us on the Internet at: http://support.automation.siemens.com/WW/view/en/23995621

Siemens D 11.1 2009

3/5

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Technical specifications
Controlled Power Modules FSA 0.37 kW (0.5 hp) FSA 0.55 kW (0.75 hp) and 0.75 kW (1.0 hp) FSA 0.37 kW (0.5 hp) with flat heat sink FSA 0.55 kW (0.75 hp) and 0.75 kW (1.0 hp) with flat heat sink FSB 1.1 kW (1.5 hp) and 1.5 kW (2.0 hp) FSC 2.2 kW (3.0 hp) FSC 3.0 kW (4.0 hp)

Dimensions (without accessories) Width Height Depth Weight, approx. Without filter With filter

90 150 116 0.7 0.8

90 150 131 0.8 0.9

90 150 101 0.6 0.7

90 150 101 0.7 0.8

140 160 142 1.4 1.5

184 181 152 1.9 2.1

184 181 152 2.0 2.2

Technical specifications for version with flat heat sink The design with flat heat sink offers space-saving and favorable heat dissipation since an additional heat sink can be installed outside the control cabinet.
Controlled Power Modules frame size FSA with flat heat sink 0.12 kW (0.16 hp) Operating temperature Total power losses at full load and maximum operating temperature as specified Line-side and control electronics losses 10 +50 C 22 W 0.25 kW (0.33 hp) 10 +50 C 28 W 0.37 kW (0.5 hp) 10 +50 C 36 W 0.55 kW (0.75 hp) 10 +50 C 43 W 0.75 kW (1.0 hp) 10 +40 C 54 W

9W

10 W 2.2 K/W 1.7 A

12 W 1.6 K/W 2.3 A

13 W 1.2 K/W 3.2 A

15 W 1.2 K/W 3.9 A

Recommended thermal resistance of 3.0 K/W heat sink Recommended output current 0.9 A

Derating data and power loss Pulse frequency


Power kW 0.12 0.25 0.37 0.55 0.75 (at 40 C) 0.75 1.1 1.5 (at 40 C) 1.5 2.2 3.0 (at 40 C) 3.0 hp 0.16 0.33 0.5 0.75 1.0 (at 40 C) 1.0 1.5 2.0 (at 40 C) 2.0 3.0 4.0 (at 40 C) 4.0 Power loss W 22 28 36 43 54 54 86 118 118 174 210 210 Rated output current in A for a pulse frequency of 2 kHz 0.9 1.7 2.3 3.2 3.9 3.2 6.0 7.8 6.0 11.0 13.6 11.0 4 kHz 0.9 1.7 2.3 3.2 3.9 3.2 6.0 7.8 6.0 11.0 13.6 11.0 6 kHz 0.9 1.7 2.3 3.2 3.9 3.2 6.0 7.8 6.0 11.0 13.6 11.0 8 kHz 0.9 1.7 2.3 3.2 3.9 3.2 6.0 7.8 6.0 11.0 13.6 11.0 10 kHz 0.9 1.7 2.3 3.0 3.6 3.0 5.9 7.6 5.9 10.8 13.3 10.8 12 kHz 0.9 1.7 2.3 2.7 3.3 2.7 5.7 7.4 5.7 10.5 12.9 10.5 14 kHz 0.9 1.7 2.3 2.5 3.0 2.5 5.6 7.2 5.6 10.2 12.6 10.2 16 kHz 0.9 1.7 2.3 2.2 2.7 2.2 5.4 7.0 5.4 9.9 12.3 9.9

The current data apply to an ambient temperature of 50 C unless specified otherwise.

3/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Technical specifications
Compliance with standards CE mark In the standard EN 61800-3 from July 2005, a distinction is no longer made between general availability and restricted availability. Instead, different categories C1 to C4 have been defined in accordance with the environment of the PDS at the operating location: - Category C1: Drive systems for rated voltages < 1000 V for use in the first environment - Category C2: Stationary drive systems not connected by means of a plug connector for rated voltages < 1000 V. When used in the first environment, the system must be installed and commissioned by personnel familiar with EMC requirements. A warning note is required. - Category C3: Drive systems for rated voltages < 1000 V for exclusive use in the second environment. A warning note is required. - Category C4: Drive systems for rated voltages 1000 V or for rated currents 400 A or for use in complex systems in the second environment. An EMC plan must be generated. The EMC product standard EN 61800-3 also defines limit values for conducted interference and radiated interference for the so-called second environment (= industrial power supply systems that do not supply households). These limit values are below the limit values of filter class A to EN 55011. Unfiltered inverters can be used in industrial environments as long as they are part of a system that contains line filters on the higher-level infeed side. With SINAMICS G110, Power Drive Systems (PDS) that fulfill the EMC product standard EN 61800-3 can be configured when observing the installation instructions in the product documentation. The table Overview of SINAMICS G110 components and PDS categories and the SINAMICS G110 ordering documentation show which of the components can be installed directly in a PDS. A differentiation must be made between the product standards for electrical drive systems (PDS) of the range of standards EN 61800 (of which Part 3 covers EMC topics) and the product standards for the devices/systems/machines, etc. This will probably not result in any changes in the practical use of frequency inverters. Since frequency inverters are always part of a PDS and these are part of a machine, the machine manufacturer must observe various standards depending on their type and environment (e.g. EN 61000-3-2 for line harmonics and EN 55011 for radio interference). The product standard for PDS on its own is, therefore, either insufficient or irrelevant. With respect to the compliance with limits for line supply harmonics, the EMC product standard EN 61800-3 for PDS refers to compliance with the EN 61000-3-2 and EN 61000-3-12 standards. Regardless of the configuration with SINAMICS G110 and its components, the machine construction company (OEM) can also implement other measures to ensure that the machine complies with the EU EMC Directive. The EU EMC Directive is generally fulfilled when the relevant EMC product standards are observed. If they are not available, the generic standards (e.g. DIN EN 61000-x-x) can be used instead. It is important that the conducted and emitted interference at the line connection point and outside the machine remain below the relevant limit values. Any suitable technical measures can be applied to ensure this.

The SINAMICS G110 inverters meet the requirements of the Low-Voltage Directive 73/23/EEC. Low-Voltage Directive The inverters comply with the following standards listed in the official journal of the EU: EN 60204 Safety of Machinery, electrical equipment of machines EN 61800-5-1 Electrical power drive systems with variable speed Part 5-1: Requirements regarding safety electrical, thermal, and energy requirements UL listing

Inverter devices in UL category NMMS certified to UL and cUL, in compliance with UL508C. UL list number E121068. For use in environments with pollution degree 2. Also see the Internet under http://www.ul.com Machinery Directive The inverters are suitable for installation in machines. Compliance with the Machinery Directive 98/37/EC requires a separate certificate of conformity. This must be provided by the plant construction company or the organization marketing the machine. EMC Directive EN 61800-3 Variable-speed electric drives Part 3: EMC product standard including specific test methods The EMC product standard EN 61800-3 has been valid for electric drive systems since 07/01/2005. The transition period for the predecessor standard EN 61800-3/A11 from February 2001 ended on October 1, 2007. The following information applies to SINAMICS G110 frequency inverters from Siemens: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. Frequency inverters are normally only supplied to experts for installation in machines or systems. A frequency inverter must, therefore, only be considered as a component which, on its own, is not subject to the EMC product standard EN 61800-3. The inverter's operating manual, however, specifies the conditions regarding compliance with the product standard if the frequency inverter is expanded to become a PDS. For a PDS, the EMC Directive in the EU is complied with by observing the product standard EN 61800-3 for variable-speed electric drive systems. The frequency inverters on their own do not generally require identification according to the EMC Directive.

Siemens D 11.1 2009

3/7

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Technical specifications
Overview of SINAMICS G110 components and PDS categories
First environment (Residential, commercial) Category C1 Unfiltered devices and external filter class B with low leakage currents (shielded motor cable up to 5 m) Category C2 All devices with integrated filter (shielded motor cable up to 5 m) or All devices with integrated filter (frame size FSA: up to 10 m; frame sizes FSB and FSC: shielded motor cable up to 25 m) plus warning note or All devices with integrated filter plus external filter, class B (shielded motor cable up to 25 m) Category C2 All devices with integrated filter (shielded motor cable up to 5 m) or All devices with integrated filter (frame size FSA: up to 10 m; frame sizes FSB and FSC: shielded motor cable up to 25 m) or All devices with integrated filter plus external filter, class B (shielded motor cable up to 25 m) Note: When devices with an integrated filter and a max. motor cable length of 5 m or external class B filters are used, this exceeds the requirements of EN 61800-3 by a considerable margin! Category C3 All devices with integrated filter (frame size FSA: up to 10 m; frame sizes FSB and FSC: shielded motor cable up to 25 m) or All devices with integrated filter plus external filter, class B (shielded motor cable up to 25 m) A warning note is required. Note: When devices with an integrated filter and external class B filters are used, this exceeds the requirements of EN 61800-3 by a considerable margin! Category C4 Does not apply to SINAMICS G110 Second environment (Industry)

Electromagnetic compatibility No impermissible electromagnetic emission occurs if the installation guidelines specific to the product are correctly observed. The table below lists the measured results for emission and noise immunity for the SINAMICS G110 inverters. The inverters were installed according to the guidelines with shielded motor cables and shielded control cables.
EMC phenomenon Standard/test Noise emission EN 61800-3 (first environment) Conducted via line supply cable Relevant criteria Limit value

150 kHz up to 30 MHz Unfiltered devices: not tested All devices with internal/external filter: Depending on the filter type and intended PDS installation: Category C1: The limit value corresponds to EN 55011, class B. Category C2: The limit value corresponds to EN 55011, class A, group 1. Further, all drive units with internal/external filter fulfill the limit value for Category C3 installations. The limit value corresponds to EN 55011, class A, group 2. 30 MHz to 1 GHz All devices limit value complies with EN 55011, class A, group 1. 8 kV 6 kV 10 V/m 4 kV 2 kV 10 V

Emitted by the drive

ESD immunity EN 61000-4-2 Noise immunity to electrical fields EN 61000-4-3

ESD through air discharge ESD through contact discharge Electrical field applied to the device

Test severity level 3 Test severity level 3 Test severity level 3 80 MHz up to 1 GHz Test severity level 4 Test severity level 3 Test severity level 3 0.15 MHz to 80 MHz 80 % AM (1 kHz)

Noise immunity to interference pulses Applied to all cable connecEN 61000-4-4 tions Impulse withstand voltage EN 61000-4-5 Noise immunity to HF interference, conducted EN 61000-4-6 Applied to the line supply cable Applied to line supply, motor and control cables

3/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Accessories
Basic Operator Panel (BOP) Commissioning tool STARTER is a commissioning tool with a graphic user interface for commissioning SINAMICS G110 frequency inverters in Windows NT/2000/XP Professional. It can be used to read, change, store, enter and print parameter lists. Selection and ordering data The accessories listed here are suitable for all SINAMICS G110 inverters.
Accessories BOP (Basic Operator Panel) PC Inverter Connection Kit including a 9-pin Sub-D connector, an RS232 standard cable (3 m), and the STARTER commissioning tool 1) on DVD Adapter for mounting on DIN rails Size 1 (frame size FSA) Size 2 (frame size FSB) SD Manual Collection on DVD 2) multi-language All manuals for the low-voltage motors, geared motors and low-voltage inverters SD Manual Collection on DVD 2) multi-language, update service for 1 year STARTER commissioning tool 1) on DVD
new

Order No. 6SL3255-0AA00-4BA1 6SL3255-0AA00-2AA1

6SL3261-1BA00-0AA0 6SL3261-1BB00-0AA0 6SL3298-0CA00-0MG0

The BOP can be used to make individual parameter settings. Values and units are displayed on a 5-digit display. One BOP can be used for several inverters. It is plugged directly onto the inverter. The BOP provides a function to quickly copy parameters. A parameter set of one inverter can be saved and then loaded to another inverter. PC Inverter Connection Kit

new

6SL3298-0CA10-0MG0

6SL3072-0AA00-0AG0

For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool) has been installed. Isolated RS232 adapter module for a reliable point-to-point connection to a PC. The scope of delivery includes a 9-pin Sub-D connector, an RS232 standard cable (3 m) and the STARTER commissioning tool 1) on DVD.

1)

The STARTER commissioning tool is also available on the Internet under http://support.automation.siemens.com/WW/view/en/10804985/133100

2)

Subject to export regulations: AL: N and ECCN: 5D992

Siemens D 11.1 2009

3/9

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Dimensional drawings
140 (5.51) 127 (5.0) 116 (4.57)

90 (3.54) 79 (3.11)

142 (5.59)

Inverter frame size FSA; 0.12 kW to 0.37 kW (0.16 hp to 0.5 hp)

Inverter frame size FSB; 1.1 kW to 1.5 kW (1.5 hp to 2.0 hp)

90 (3.54) 79 (3.11)

184 (7.24) 170 (6.70) 131 (5.16)

152 (5.98)

140 (5.51) 150 (5.91)

140 (5.51)

G_D011_EN_00029

181 (7.13)

G_D011_EN_00031
G_D011_EN_00032

G_D011_EN_00028

140 (5.51)

150 (5.91)

Inverter frame size FSA; 0.55 kW to 0.75 kW (0.75 hp to 1.0 hp)

Inverter frame size FSC; 2.2 kW to 3.0 kW (3.0 hp to 4.0 hp)

90 (3.54) 79 (3.11)

101(4.01)

Mounted using screws and washers (not included in the scope of supply) Frame size FSA: 2 M4 Frame size FSB: 4 M4 Frame size FSC: 4 M5 With attached operator panel (BOP), the mounting depth is increased by 8 mm (0.31 inches).
G_D011_EN_00030

140 (5.51) 150 (5.91)

All dimensions in mm (values in brackets are in inches).

Inverter frame size FSA with flat heat sink; 0.12 kW to 0.75 kW (0.16 hp to 1.0 hp)

3/10

Siemens D 11.1 2009

135 (5.31) 160 (6.30)

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Controlled Power Modules

Circuit diagrams
Overview circuit diagram

Basic Operator Panel (accessories)

200 V to 240 V 1 AC

JOG

PE
FS1

PE

L1, L2/N

Analog variant
Input voltage 0 V to + 10 V AIN+ 9

+10 V 8

+ -

or
0V 10

AIN+ 9 > 4.7 k 0 V 10

A D

USS variant
P+

A RS485

AC

N-

DC

DC+ 60 Bus Hz Termination DC -

CPU

max. 30 V max. 5 mA
3 4 5

50 OFF Hz

DIN0 DIN1 DIN2

3 4 5

DIN0 DIN1

DC

or

DIN2

+ 24 V -

AC
7 6 7 +24 V (max. 50 mA) 0V

DOUT-

PE

U, V, W

For an additional digital input (DIN 3) external connections should be made:


DIN3 9 DIN3 9

M 3~

24 V 0V 7

or
24 V 6

G_D011_EN_00027

DOUT+ 24 V DC 50 mA

Siemens D 11.1 2009

3/11

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Starter Kit

Overview

Selection and ordering data


Order No. Starter Kit 0.75 kW (1.0 hp), German 6SL3200-0AB10-0AA0

The SINAMICS G110 Starter Kit offers an easy introduction into the world of variable-speed drives. Accommodated in a stackable transport case, it contains: Inverter (0.75 kW/1.0 hp) with analog input and integrated EMC filter BOP operator panel PC Inverter Connection Kit Short description, operating instructions, and parameter list (hard copy, in German) STARTER commissioning tool 1) on DVD (incl. operating instructions, parameter list and Getting Started guide) Screwdriver

1)

The STARTER commissioning tool is also available on the Internet under http://support.automation.siemens.com/WW/view/en/10804985/133100

3/12

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Line-side power components

Overview
Integrated EMC filter Versions with integrated EMC filters class A and class B are available for the corresponding environments. Class A The requirements are fulfilled when shielded cables with a max. length of 10 m (for frame size FSA) or 25 m (for frame sizes FSB and FSC) are used. The limits comply with EN 55011 class A for conducted interference. Class B The requirements are fulfilled when shielded cables with a max. length of 5 m are used. The limits comply with EN 55011 class B for conducted interference. An inverter with an integrated filter can be used with a 30 mA residual-current circuit breaker and is only suitable for installations with fixed wiring. Inverters without filters, which are used with EMC filter class B with low leakage currents, have a leakage current < 3.5 mA (up to 5 m shielded motor cable). Additional EMC filter, class B Available for inverters with an internal EMC filter. With this filter, the inverter complies with the emission standard EN 55011, class B for conducted interference. The requirements are fulfilled using shielded cables with a max. length of 25 m. EMC filter, class B with low leakage currents With this filter, the unfiltered inverter complies with the emission standard EN 55011, class B for conducted interference. The leakage currents are reduced to < 3.5 mA. Unfiltered inverters can, therefore, be used for drive systems in Category C1 installations. The requirements are fulfilled for Shielded cables with a max. length of 5 m Installation of the inverter in a metal housing (e.g. control cabinet) Pulse frequency of 16 kHz (only for frame sizes FSB and FSC) For Category C1 installations, generally a pulse frequency of 16 kHz is recommended for inverter operation in the inaudible spectrum and for quiet motor operation. Line reactor Line reactors are used to smooth voltage peaks or to bridge commutating dips. Line reactors also reduce the effects of harmonics on the inverter and the line supply. If the ratio of the rated inverter power to the line supply short-circuit power is less than 1 %, a line reactor must be used in order to reduce the current peaks. In line with EN 61000-3-2 regulations Limits for harmonic currents with device input current 16 A per phase, there are special aspects for drives with 120 W to 550 W and 230-V singlephase line supplies which are used in non-industrial applications (first environment). For devices with 120 W to 370 W, either the recommended line reactors must be installed or permission obtained from the power utility company for the connection to the public supply system. In accordance with the specifications of EN 61000-3-12 Limits for harmonic currents > 16 A and 75 A per phase, permission must be obtained from the power utility to operate drives connected to the public low-voltage line supply. The harmonic current values should be taken from the operating instructions.

Technical specifications
EMC filters and line reactors cannot be installed as base components.
EMC filter, class B with low leakage currents 6SE6400-2FL01-0AB0 Dimensions Width Height Depth Weight, approx. mm mm mm kg 73 200 43.5 0.5 149 213 50.5 1 73 200 43.5 0.5 149 213 50.5 1 185 245 55 1.5 6SE6400-2FL02-6BB0 Additional EMC filter, class B 6SE6400-2FS01-0AB0 6SE6400-2FS02-6BB0 6SE6400-2FL03-5CB0

Line reactor 6SE6400-3CC00-4AB3 Dimensions Width Height Depth Weight, approx. mm mm mm kg 75.5 200 50 1.31 75.5 200 50 1.32 150 213/233 1) 50 2.2 185 245/280 1) 50 3.05 6SE6400-3CC01-0AB3 6SE6400-3CC02-6BB3 6SE6400-3CC03-5CB3

1)

The 233 mm or 280 mm dimensions are valid for lateral mounting using a mounting bracket.

Siemens D 11.1 2009

3/13

Siemens AG 2009

SINAMICS G110
Standard inverters 0.12 kW to 3 kW (0.16 hp to 4.0 hp)
Line-side power components

Selection and ordering data


The line-side power components listed here must be selected in accordance with the particular inverter. EMC filters and line reactors cannot be installed as base components. The inverter and associated line-side power components have the same rated voltage.
Power EMC filter, class B with low leakage currents hp 0.16 0.33 0.50 0.75 1.0 1.5 2.0 3.0 4.0 0.16 0.33 0.50 0.75 1.0 1.5 2.0 3.0 4.0 Order No. 6SE6400-2FL01-0AB0 6SE6400-2FL01-0AB0 6SE6400-2FL01-0AB0 6SE6400-2FL01-0AB0 6SE6400-2FL01-0AB0 6SE6400-2FL02-6BB0 6SE6400-2FL02-6BB0 6SE6400-2FL02-6BB0 Line reactor Order No. 6SE6400-3CC00-4AB3 6SE6400-3CC00-4AB3 6SE6400-3CC01-0AB3 6SE6400-3CC01-0AB3 6SE6400-3CC01-0AB3 6SE6400-3CC02-6BB3 6SE6400-3CC02-6BB3 6SE6400-3CC02-6BB3 6SE6400-3CC03-5CB3 6SE6400-3CC00-4AB3 6SE6400-3CC00-4AB3 6SE6400-3CC01-0AB3 6SE6400-3CC01-0AB3 6SE6400-3CC01-0AB3 6SE6400-3CC02-6BB3 6SE6400-3CC02-6BB3 6SE6400-3CC02-6BB3 6SE6400-3CC03-5CB3

All line-side power components are certified to UL (with the exception of fuses). 3NA3 fuses are recommended for European countries. Additional information about the listed fuses and circuit breakers can be found in Catalogs LV 1 and LV 1 T. UL-listed fuses such as the class NON fuse series from Bussmann are required for North American market.
Additional EMC filter, class B Order No. 6SE6400-2FS01-0AB0 6SE6400-2FS01-0AB0 6SE6400-2FS01-0AB0 6SE6400-2FS01-0AB0 6SE6400-2FS01-0AB0 6SE6400-2FS02-6BB0 6SE6400-2FS02-6BB0 6SE6400-2FS02-6BB0 6SE6400-2FS03-5CB0 Fuse Order No. 3NA3803 3NA3803 3NA3803 3NA3803 3NA3805 3NA3807 3NA3810 3NA3814 3NA3820 3NA3803 3NA3803 3NA3803 3NA3803 3NA3805 3NA3807 3NA3810 3NA3814 3NA3820 Circuit breaker Order No. 3RV1021-1DA10 3RV1021-1FA10 3RV1021-1HA10 3RV1021-1JA10 3RV1021-1KA10 3RV1021-4BA10 3RV1021-4CA10 3RV1031-4EA10 3RV1031-4FA10 3RV1021-1DA10 3RV1021-1FA10 3RV1021-1HA10 3RV1021-1JA10 3RV1021-1KA10 3RV1021-4BA10 3RV1021-4CA10 3RV1031-4EA10 3RV1031-4FA10

kW 0.12 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0 0.12 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.0

Line-side power components for inverters without EMC filter

Line-side power components for inverters with integrated EMC filter, class A/B

3/14

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120 Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)


4/2 4/2 4/4 4/4 4/4 4/9 4/10 4/12 4/12 4/12 4/12 4/13 4/14 4/17 4/19 4/19 4/19 4/20 4/22 4/28 4/30 4/30 4/31 4/32 4/36 4/42 4/44 4/50 4/50 4/51 4/52 4/55 4/59 4/60 4/64 4/64 4/65 4/66 4/68 4/71 4/72 4/73 4/73 4/73 SINAMICS G120 standard inverters Overview Benefits Applications Design Configuration Technical specifications CU230 Control Units Overview Selection and ordering data Function Design Integration Technical specifications CU240 Control Units Overview Selection and ordering data Design Integration Technical specifications PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp) Overview Selection and ordering data Integration Technical specifications Characteristic curves Dimensional drawings PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp) Overview Selection and ordering data Integration Technical specifications Characteristic curves Dimensional drawings PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp) Overview Selection and ordering data Integration Technical specifications Characteristic curves Dimensional drawings Compact inverters 0.37 kW to 15 kW (0.5 hp to 20 hp) Overview Selection and ordering data 4/74 4/74 4/77 4/81 4/83 4/83 4/86 4/88 4/88 4/95 4/102 4/102 4/104 4/105 4/106 4/108 4/108 4/109 4/110 4/111 4/111 4/112 4/112 4/113 4/113 4/113 4/114 4/114 4/115 4/116

Line-side power components Line filters Line reactors Recommended line components DC link components Braking resistors Braking Modules Load-side power components Output reactors Sine-wave filters Supplementary system components Intelligent Operator Panel IOP Basic Operator Panel BOP MMC memory card CM240NE chemical industry module PC Connection Kit -2 PC Connection Kit Brake relay Safe Brake Relay Adapter for mounting on DIN rails Shield Connection Kit Shield Connection Kit 1 for CU230P-2 Control Units Shield Connection Kit for CU240S Control Units Spare parts CU240 Spare Parts Kit Replacement door for PM240 frame size FSGX Terminal Cover Kit for frame sizes FSD and FSE Terminal Cover Kit for frame size FSF Replacement connector Replacement fan

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Overview
The SINAMICS G120 frequency inverter is designed to provide precise and cost-effective speed/torque control of AC motors. With different device versions (frame sizes FSA to FSGX) in a power range from 0.37 kW to 250 kW (0.5 hp to 400 hp), it is suitable for a wide variety of drive solutions.

Examples of SINAMICS G120, frame sizes FSA, FSB and FSC; each with Power Module, Control Unit and Basic Operator Panel

Examples of SINAMICS G120, frame sizes FSD, FSE and FSF; each with Power Module, Control Unit and Basic Operator Panel

4/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Overview
Safety Integrated The SINAMICS G120 standard inverters are available in a number of different versions for safety-related applications. All Power Modules are already designed for Safety Integrated. A Safety Integrated Drive can be created by combining a Power Module with the appropriate Fail-safe Control Unit. The SINAMICS G120 fail-safe frequency inverter provides four safety functions, certified in accordance with EN 954-1, Category 3 and IEC 61508 SIL 2: Safe Torque Off (STO) to protect against active movement of the drive Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp Safely Limited Speed (SLS) for protection against dangerous movements when a speed limit is exceeded Safe Brake Control (SBC) for controlling motor brakes that are active in the de-energized state, e.g. motor holding brakes The functions Safe Stop 1 and Safely Limited Speed can both be implemented without having to use a motor sensor or encoder; the implementation cost is minimal. Existing systems in particular can be updated with safety technology without the need to change the motor or mechanical system. The safety functions Safely Limited Speed and Safe Stop 1 are not certified for pull-through loads as in the case of lifting gear and winders. Additional information is provided in the part Highlights, section Safety Integrated.
Examples of SINAMICS G120, frame size FSGX; with Power Module

Efficient Infeed Technology The innovative Efficient Infeed Technology is used in PM250 and PM260 Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. Additional cooling and additional space requirement in the control cabinet can be avoided as components such as braking resistors, brake choppers and line reactors are not required. Further, wiring and engineering costs are significantly reduced. At the same time, considerable savings can be achieved in terms of energy consumption and operating costs. Additional information is included in the part Highlights, section Efficient Infeed Technology. Innovative cooling concept and coated electronic modules The innovative cooling concept and coated electronic modules significantly increase the service life and usage time of the device. These features are based on the following principles: The power loss is exclusively dissipated using an external heat sink Electronic modules not located in air duct Standardized convection cooling of Control Unit All cooling air from the fan is directed through the heat sink STARTER commissioning tool The STARTER commissioning tool simplifies the commissioning and maintenance of SINAMICS G120 inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.

Modularity SINAMICS G120 is a modular inverter system comprising a variety of functional units. The main units are: the Control Unit (CU) the Power Module (PM) The Control Unit controls and monitors the Power Module and the connected motor using several different control types that can be selected. It supports communication with a local or central control and monitoring devices. The Power Module supplies the motor in a power range 0.37 kW to 250 kW (0.5 hp to 400 hp). The Power Module is controlled by a microprocessor in the Control Unit. State-of-the-art IGBT technology with pulse-width modulation is used to achieve the highest degree of reliability and flexible motor operation. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor. Furthermore, a large number of additional components are available, such as: Intelligent Operator Panel (IOP) for parameterizing, diagnosing, controlling and copying drive parameters Basic Operator Panel (BOP) for parameterizing, diagnosing, controlling and copying drive parameters Line filters, Classes A and B Line reactors Braking resistors Sine-wave filters Output reactors

Siemens D 11.1 2009

4/3

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Benefits
7

Design
SINAMICS G120 standard inverters are modular frequency inverters for standard drives. Each SINAMICS G120 comprises two operative units the Power Module and Control Unit. Each Control Unit can be combined with each Power Module. Guidelines for module selection The procedure to select a complete SINAMICS G120 frequency inverter should be as follows:
1. 2. 3. Select a suitable Control Unit (depending on the required communication, hardware and software version and safety functionality) Select a suitable Power Module (depending on the power and technology required) Select the optional and additional components. There are a large number of components for expanding the system (e.g. line-side power components, DC link components, load-side power components, and supplementary system components). However, it should be noted that not all of the components are required for all of the Power Modules (example: Braking resistors are not required for the PM250 and PM260 Power Modules!). The precise data is provided in the technical specifications tables of the particular components.

7 7

4
7

7 7 7 7 7

Modularity ensures flexibility for a drive concept that is fit-forthe-future - Modules can be replaced under voltage (hot swapping) - Pluggable terminals - The modules can be easily replaced, which makes the system extremely service friendly. The safety functions make it easier to integrate drives into safety-oriented machines or plants Communications-capable via PROFINET or PROFIBUS with PROFIdrive Profile 4.0 - Reduced number of interfaces - Plantwide engineering - Easy to handle The innovative circuit design (bidirectional input rectifier with pared-down DC link) allows the kinetic energy of a load to be fed back into the supply system when Power Modules PM250 and PM260 are used. This feedback capability provides enormous potential for savings because generated energy no longer has to be converted into heat in a braking resistor Innovative SiC semiconductor technology ensures that when a PM260 Power Module is used, the inverter is more compact than a comparable standard converter with an optional sinewave filter for the same power rating An innovative cooling concept and coated electronic modules increase robustness and service life - External heatsink - Electronic components are not located in air duct - Control Unit that is completely cooled by convection - Additional coating of the most important components Simple unit replacement and quick copying of parameters using the optional Basic Operator Panel or the optional MMC memory card Quiet motor operation as a result of the high pulse frequency Compact, space-saving design Software parameters for simple adaptation to 50 Hz or 60 Hz motors (IEC or NEMA motors) 2-/3-wire control (static/pulsed signals) for universal control via digital inputs (only CU240 Control Units) Engineering and commissioning with uniform engineering tools such as SIZER, STARTER, and Drive ES: ensure fast engineering and easy commissioning STARTER is integrated in STEP 7 with Drive ES Basic with all the advantages of central data storage and totally integrated communication Certified worldwide for compliance with CE, UL, cUL, c-tick and Safety Integrated according to IEC 61508 SIL 2

Control Units The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. Two series of Control Units are available for SINAMICS G120 corresponding to their software packages (CU230 and CU240). Each Control Unit comprises a defined I/O quantity structure, a special fieldbus interface and possible additional safety functions. The following Control Units and accessories are available for standard SINAMICS G120 inverters: CU230 Control Units The CU230P-2 Control Units have been specifically designed for pump, fan and compressor applications. The following three versions are available: CU230P-2 HVAC CU230P-2 DP CU230P-2 CAN CU240 Control Units Several Control Units are available in different versions: CU240E CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F

Applications
SINAMICS G120 is ideally suited as a universal drive in all industrial and commercial applications e.g. in the automotive, textile, printing and chemical industries for higher-level applications, e.g. in conveyor systems

4/4

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Design
Power Modules The following Power Modules are available for the SINAMICS G120 standard inverters: PM240 Power Modules PM240 Power Modules (0.37 kW to 250 kW / 0.5 hp to 400 hp) feature an integrated brake chopper (for frame size FSGX external) and are designed for drives without energy recovery capability. Generator energy produced during braking is converted to heat via externally connected braking resistors. PM250 Power Modules PM250 Power Modules (7.5 kW to 90 kW / 10 hp to 125 hp) have an innovative circuit design which allows line-commutated energy recovery back into the line supply. This innovative circuit permits generator energy to be fed back into the supply system and therefore saves energy. PM260 Power Modules PM260 Power Modules (11 kW to 55 kW / 15 hp to 75 hp) also have an innovative circuit design which allows line-commutated energy recovery back into the line supply. This innovative circuit permits generator energy to be fed back into the supply system and therefore saves energy. The PM260 Power Modules also have an integrated sine-wave filter that limits the rate of rise of voltage and the capacitive charging/discharging currents usually associated with inverter operation. Line-side power components The following line-side power components are available for SINAMICS G120 standard inverters: Line filters With one of the additional line filters, the Power Module reaches a higher radio interference class. Line reactors (for PM240 Power Modules only) A line reactor reduces the system perturbations caused by harmonics. This particularly applies in the case of weak line supplies (line supply short-circuit power uK > 1 %). Recommended line components This is a recommendation for additional line-side components, such as fuses and circuit-breakers (line-side components must be dimensioned in accordance with IEC standards). Additional information about the listed fuses and circuit breakers can be found in Catalogs LV 1 and LV 1 T. DC link components The following DC link components are available for the SINAMICS G120 standard inverters: Braking Modules (only for PM240 Power Modules, frame size FSGX) A Braking Module and the matching external braking resistor are required to bring drives with a PM240 Power Module, frame size FSGX to a controlled standstill in the event of a power failure (e.g. emergency retraction or EMERGENCY STOP Category 1) or limit the DC link voltage during a short period of generator operation. The Braking Module includes the power electronics and the associated control circuit. Braking resistors (for PM240 Power Modules only) Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with PM240 Power Modules. They are equipped with an integrated brake chopper (electronic switch). There is an optional plug-in Braking Module for frame size FSGX. Load-side power components The following load-side power components are available for the SINAMICS G120 standard inverters. This means that during operation with output reactors or sine-wave filters, longer, shielded motor cables are possible and the motor service life can be extended: Output reactors (for PM240 and PM250 Power Modules only) Output reactors reduce the voltage stress on the motor windings. At the same time, the capacitive charging/discharging currents, which place an additional load on the power unit when long motor cables are used, are reduced. Sine-wave filter (not for PM260 Power Modules) The sine-wave filter limits the rate of rise of voltage and the capacitive charging/discharging currents that usually occur with inverter operation. An output reactor is not required.

Siemens D 11.1 2009

4/5

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Design
Power and DC link components which are optionally available depending on the Power Module used The following line-side power components, DC link components and load-side power components are optionally available in the appropriate frames sizes for the Power Modules:
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


F/S 3) S S S S S 3) S S I (Option) S S

Available frame sizes Line filter, class A

Line-side power components U U U U U U F U U U U U F U U S U U F U S S S F U S S S

Line filter, class B Line reactor DC link components Braking resistor Braking Module Output reactor Sine-wave filter Available frame sizes Line filter, class A Line filter, class B Line reactor 1) DC link components Braking resistor 2) Output reactor Sine-wave filter Available frame sizes Line filter, class A Line filter, class B Line reactor 1) DC link components Braking resistor 2) Output reactor Sine-wave filter U S I F = = = = =

Load-side power components

PM250 Power Module with line-commutated energy recovery


Line-side power components I U 1) 2) U U F 1) 2) S S F 1) 2) S S F 1) 2) S S

Load-side power components

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter
Line-side power components F 1) 2) I F 1) 2) I

Load-side power components

Base component Lateral mounting Integrated Not possible Power Modules available with and without integrated class A filter

1) 2)

A line reactor is not required and must not be used in conjunction with a PM250 or PM260 Power Module. Line-commutated energy recovery is possible in conjunction with a PM250 or PM260 Power Module. A braking resistor cannot be connected and is not necessary.

3)

PM240 FSF Power Modules, from 110 kW (150 hp) and higher and FSGX are only available without an integrated class A filter. An optional class A line filter for side mounting is available instead.

4/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Design
General design information
Inverter chassis unit SINAMICS G120 Base components e. g. Filter e. g. Reactor Mounting surface or cabinet wall

CU

PM

A maximum of two base components plus inverter are possible. The line filter has to be mounted directly below the frequency inverter (position 1). With lateral mounting, the line-side components have to be mounted on the left side of the frequency inverter and the load-side components on the right side. Braking resistors have to be mounted directly on the control cabinet wall due to heating issues.

G_D011_EN_00187

Position 1

Position 2

Frequency inverters comprising a Power Module (PM) and a Control Unit (CU) and two base components at position 1 and position 2 (side view)

Recommended installation combinations of the inverter and optional power and DC link components
Power Modules Frame size Base Position 1 Position 2 Lateral mounting left of the inverter (for line-side power components) right of the inverter (for load-side power components and DC link components) Output reactor or sine-wave filter and/or braking resistor Braking resistor

FSA and FSB

Line filter

Line reactor

Line filter or line reactor Line filter or line reactor Line filter or line reactor or braking resistor FSC Line filter

Output reactor or sine-wave filter Braking resistor

Line reactor

Output reactor or sine-wave filter and/or braking resistor Braking resistor Output reactor or sine-wave filter and/or braking resistor Output reactor or sine-wave filter and/or braking resistor Output reactor or sine-wave filter and/or braking resistor

Line filter or line reactor FSD and FSE Line reactor

Output reactor or sine-wave filter

Line filter

FSF

Line filter and/or line reactor Line filter and/or line reactor

FSGX

Siemens D 11.1 2009

4/7

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Design
Maximum permissible cable lengths from the motor to the inverter when using output reactors or sine-wave filters depending on the voltage range and the Power Module being used The following load-side power components in the appropriate frame sizes are optionally available for the Power Modules and result in the following maximum cable lengths:
Maximum permissible motor cable lengths (shielded/unshielded) in m Frame sizes FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


50/100 150/225 100/150 200/300 200/300 50/100 150/225 100/150 200/300 200/300 50/100 200/300 200/300 200/300 200/300 50/100 200/300 200/300 200/300 200/300 100/100 200/300 200/300 200/300 200/300 50/100 200/300 200/300 200/300 200/300 150/150 200/300 200/300 200/300 200/300 50/100 200/300 200/300 200/300 200/300 300/450 300/450 300/450 300/450 300/450

Available frame sizes With optional output reactor at 380 V ( 10 %) to 400 V 3 AC at 401 V to 480 V (+ 10 %) 3 AC With optional sine-wave filter at 380 V ( 10 %) to 400 V 3 AC at 401 V to 480 V (+ 10 %) 3 AC Available frame sizes With optional output reactor at 380 V ( 10 %) to 400 V 3 AC at 401 V to 480 V (+ 10 %) 3 AC With optional sine-wave filter at 380 V ( 10 %) to 400 V 3 AC at 401 V to 480 V (+ 10 %) 3 AC Available frame sizes With integrated sine-wave filter at 500 V to 690 V 3 AC ( 10 %)

50/100 150/225 100/150 200/300 200/300

Without output reactor/sine-wave filter 50/100 150/225 100/150 200/300 200/300

PM250 Power Module with line-commutated energy recovery


Without output reactor/sine-wave filter

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter

200/300

200/300

4/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Design
Supplementary system components The following supplementary system components are available for the SINAMICS G120 standard inverters: Intelligent Operator Panel IOP The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, the menu prompting and the Application Wizards, it is easy to commission, diagnose and locally control standard drives. Operator Panel BOP (not for CU230P-2 Control Units) The Basic Operator Panel BOP can be plugged onto the Control Unit and can be used to commission drives, monitor drives in operation and input individual parameter settings. The BOP also provides a function to quickly copy parameters. MMC memory card (not for CU240E Control Units) The parameter settings for an inverter can be stored on the MMC memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again. The associated slot is located on the top of the Control Unit. CM240NE chemical industry module Inverters for 400 V / 500 V and 690 V are required in the chemical industry that meet the special demands and requirements of this industry sector. The essential requirements and demands of the chemical industry are fulfilled using the SINAMICS G120 series of inverters supplemented by the CM240NE chemical industry module (with ATEX-certified PTC evaluation and a NAMUR terminal strip). PC Inverter Connection Kit For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool) has been installed. The STARTER commissioning tool on DVD is included in the PC Inverter Connection Kit. Brake Relay The Brake Relay allows the Power Module to be connected to an electromechanical motor brake, thereby allowing the motor brake to be driven directly by the Control Unit. Safe Brake Relay The Safe Brake Relay allows the Power Module to be connected to an electromechanical motor brake, allowing the brake to be directly and safely controlled from the Control Unit in accordance with EN 954-1 Category 3 and IEC 61508 SIL 2. Adapter for mounting on DIN rails The adapter for mounting on DIN rails can be used to mount inverters of the sizes FSA and FSB on DIN mounting rails (2 units with a center-to-center distance of 100 mm). Shield Connection Kit The Shield Connection Kit makes it easier to connect the shields of supply and control cables, offers mechanical strain relief and thus ensures optimum EMC performance. Shield Connection Kit for CU240S and CU230P-2 The Shield Connection Kit offers optimum shield connection and strain relief for all signal and communication cables. It includes a matching shield bonding plate and all of the necessary connecting and retaining elements for mounting.

Spare parts Spare Parts Kit for CU240 The kit includes a replacement cover for the terminals, a suitable shield bar for the CU240E Control Unit including screws, replacement connector for the CU240S Control Unit, protective element of the MMC card slot and screws to attach the shield bonding plate of the CU240S Control Unit. Terminal Cover Kit The kit includes a replacement cover for the terminals. The kit can be ordered for PM240 Power Modules, frame sizes FSD, FSE and FSF, as well as for the PM260, frame size FSF. PM260 replacement connector This spare part includes a connector for the input and output sides for the PM260 Power Module, frame size FSD. SINAMICS G120 PM240 FSGX replacement door A complete replacement door can be ordered for the PM240 Power Module, frame size FSGX. Replacement fan The Power Module fans are designed for extra long service life. Replacement fans can be ordered for special applications.

Configuration
The following electronic configuring and engineering tools are available for the SINAMICS G120 standard inverters: Selection guide, SD Configurator More than 100000 products with approximately 5 million possible product versions from the area of drive technology are listed in the interactive Catalog CA 01 the Offline Mall from Siemens IA&DT. In order to make it easier to select the optimum motor and/or inverter from the wide range of Standard Drives, the SD Configurator was developed, which is integrated as Selection guide in this catalog on the DVD together with the selection and engineering tools. Online SD Configurator In addition, the SD Configurator can be used in the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com/dt-configurator SIZER configuration tool The SIZER PC tool makes it easy to configure the SINAMICS and MICROMASTER 4 drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER supports the configuration of the complete drive system, from simple single-motor drives up to complex multi-axis applications. STARTER commissioning tool The STARTER commissioning tool is used to commission, optimize and diagnose drives in a menu-prompted fashion. In addition to SINAMICS drives, STARTER is also suitable for MICROMASTER 4 units and the frequency converters for the distributed I/O SIMATIC ET 200S FC and SIMATIC ET 200pro FC. Drive ES engineering system Drive ES is the engineering system used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. The STEP 7 Manager user interface forms the basis. Various software packages are available for SINAMICS: Drive ES Basic, Drive ES SIMATIC and Drive ES PCS 7.

Siemens D 11.1 2009

4/9

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Technical specifications
Unless explicitly specified otherwise, the following technical specifications are valid for all the following components of the SINAMICS G120 standard inverters.
Mechanical specifications
Vibratory load Transport 1) acc. to EN 60721-3-2 - All units and components Class 2M3 except frame size FSGX - Units with frame size FSGX Class 2M2 Operation Test values acc. to EN 60068-2-6 Test Fc: 10 58 Hz: Constant deflection 0.075 mm 58 150 Hz: Constant acceleration = 9.81 m/s2 (1 g)

Ambient conditions (continued)


Environmental class/harmful chemical substances Storage 1) acc. to EN 60721-3-1 Operation acc. to EN 60721-3-3 Organic/biological influences Storage 1) acc. to EN 60721-3-1 Operation acc. to EN 60721-3-3 Degree of pollution acc. to EN 61800-5-1 Applies to CU240 DP-F and CU240 PN-F Control Units. The values include Control Unit, Power Module and Safe Brake Relay. Category acc. to EN 954-1 SIL Cl acc. to IEC 61508 PL acc. to ISO 13849 PFHD T1 3 2 Available soon 5 108 10 Years UL, cUL, CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC Class 1B1 Class 3B1 2 Transport 1) acc. to EN 60721-3-2 Class 2B1 Class 1C2 Class 3C2 Transport 1) acc. to EN 60721-3-2 Class 2C2

Shock load Transport 1) acc. to EN 60721-3-2 - All units and components Class 2M3 except frame size FSGX Class 2M2 - Units with frame size FSGX Test Ea: 147 m/s2 (15 g)/11 ms 49 m/s2 (5 g)/30 ms 98 m/s2 (10 g)/20 ms

Certification for fail-safe versions

Operation Test values acc. to EN 60068-2-27 - Frame sizes FSA to FSC - Frame sizes FSD to FSF - Frame size FSGX

Ambient conditions
Protection class acc. to EN 61800-5-1 Touch protection acc. to EN 61800-5-1 Permissible ambient and coolant temperature (air) during operation for line-side power components and Power Modules High overload (HO) 0 50 C (32 122 F) without derating (for PM240, frame size FSGX: 0 40 C), > 50 60 C see derating characteristics 0 40 C (32 104 F) without derating (for PM240, frame size FSGX: 0 40 C), > 40 60 C see derating characteristics 10 +50 C (14 122 F) with CU240S DP-F: 0 45 C with CU240S PN-F: 0 40 C with IOP: 0 50 C up to 2000 m above sea level Class 1K3 temperature 25 +55 C Class I (with protective conductor system) and Class III (PELV) For the intended purpose

Standards
Standards conformance CE mark

EMC Directive acc. to EN 61800-3 Frame sizes FSA to FSGX without Category C3 2) integrated line filter class A Frame sizes FSB to FSF with integrated line filter class A Category C2 3) (corresponds to class A acc. to EN 55011 for conducted interference emission) Category C2 3) (corresponds to class A acc. to EN 55011 for conducted interference emission) Category C2 3) (corresponds to class B acc. to EN 55011 for conducted interference emission) Category C2 3) (corresponds to class B acc. to EN 55011 for conducted interference emission)

Light overload (LO)

Frame size FSA without integrated line filter and with additional line filter class A Frame size FSA with additional line filter class A and with additional line filter class B Frame sizes FSB and FSC with additional line filter class A and with additional line filter class B

Permissible ambient and coolant temperature (air) during operation for Control Units, additional system components and DC-link components Climatic ambient conditions Storage 1) acc. to EN 60721-3-1

Transport 1) acc. to EN 60721-3-2 Class 2K4 temperature 40 +70 C max. humidity 95 % at 40 C Operation acc. to EN 60721-3-3 Class 3K5 4) Condensation, splashwater and ice formation not permitted (EN 60204, Part 1)

Note: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the frequency inverters. The frequency inverters on their own do not generally require identification according to the EMC Directive.

1) 2)

In transport packaging. Unfiltered inverters can be used in industrial environments as long as they are part of a system that contains line filters on the higher-level infeed side. As a consequence, a PDS (Power Drive System) can be installed according to C3.

3) 4)

With shielded motor cable up to 25 m. For Intelligent Operator Panel IOP, class 3K3.

4/10

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
SINAMICS G120 standard inverters

Technical specifications
Compliance with standards CE mark - Category C1: Drive systems for rated voltages < 1000 V for use in the first environment - Category C2: Stationary drive systems not connected by means of a plug connector for rated voltages < 1000 V. When used in the first environment, the system must be installed and commissioned by personnel familiar with EMC requirements. A warning note is required. - Category C3: Drive systems for rated voltages < 1000 V for exclusive use in the second environment. A warning note is required. - Category C4: Drive systems for rated voltages 1000 V or for rated currents 400 A or for use in complex systems in the second environment. An EMC plan must be generated. The EMC product standard EN 61800-3 also defines limit values for conducted interference and radiated interference for the so-called second environment (= industrial power supply systems that do not supply households). These limit values are below the limit values of filter class A to EN 55011. Unfiltered inverters can be used in industrial environments as long as they are part of a system that contains line filters on the higher-level infeed side. With SINAMICS G120, Power Drive Systems (PDS) that fulfill the EMC product standard EN 61800-3 can be configured when observing the installation instructions in the product documentation. A differentiation must be made between the product standards for electrical drive systems (PDS) of the range of standards EN 61800 (of which Part 3 covers EMC topics) and the product standards for the devices/systems/machines, etc. This will probably not result in any changes in the practical use of frequency inverters. Since frequency inverters are always part of a PDS and these are part of a machine, the machine manufacturer must observe various standards depending on their type and environment (e.g. EN 61000-3-2 for line harmonics and EN 55011 for radio interference). The product standard for PDS on its own is, therefore, either insufficient or irrelevant. With respect to the compliance with limits for line supply harmonics, the EMC product standard EN 61800-3 for PDS refers to compliance with the EN 61000-3-2 and EN 61000-3-12 standards. Regardless of the configuration with SINAMICS G120 and its components, the machine construction company (OEM) can also apply other measures to ensure that the machine complies with the EU EMC Directive. The EU EMC Directive is generally fulfilled when the relevant EMC product standards are observed. If they are not available, the generic standards (e.g. DIN EN 61000-x-x) can be used instead. It is important that the conducted and emitted interference at the line connection point and outside the machine remain below the relevant limit values. Any suitable technical measures can be applied to ensure this.

The SINAMICS G120 inverters meet the requirements of the Low-Voltage Directive 73/23/EEC. Low-Voltage Directive The inverters comply with the following standards listed in the official journal of the EU: EN 60204 Safety of Machinery, electrical equipment of machines EN 61800-5-1 Electrical power drive systems with variable speed Part 5-1: Requirements regarding safety electrical, thermal, and energy requirements UL listing Inverter devices in UL category NMMS certified to UL and cUL, in compliance with UL508C. UL list numbers E121068 and E192450. For use in environments with pollution degree 2. Also see the Internet under http://www.ul.com Machinery Directive The inverters are suitable for installation in machines. Compliance with the Machinery Directive 98/37/EC requires a separate certificate of conformity. This must be provided by the plant construction company or the organization marketing the machine. EMC Directive EN 61800-3 Variable-speed electric drives Part 3: EMC product standard including specific test methods The EMC product standard EN 61800-3 has been valid for electric drive systems since 07/01/2005. The transition period for the predecessor standard EN 61800-3/A11 from February 2001 ended on October 1, 2007. The following information applies to SINAMICS G120 frequency inverters from Siemens: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. Frequency inverters are normally only supplied to experts for installation in machines or systems. A frequency inverter must, therefore, only be considered as a component which, on its own, is not subject to the EMC product standard EN 61800-3. The inverter's operating manual, however, specifies the conditions regarding compliance with the product standard if the frequency inverter is expanded to become a PDS. For a PDS, the EMC Directive in the EU is complied with by observing the product standard EN 61800-3 for variable-speed electric drive systems. The frequency inverters on their own do not generally require identification according to the EMC Directive. In the Standard EN 61800-3 from July 2005, a distinction is no longer made between general availability and restricted availability. Instead, different categories C1 to C4 have been defined in accordance with the environment of the PDS at the operating location:

SEMI F47 SEMI F47 is an industry standard relating to the immunity to voltage dips. This includes the requirement that industrial equipment must be able to tolerate defined dips or drops of the line supply voltage. As a result, industrial equipment that fulfills this standard is more reliable and productive. In the SINAMICS G120 product family, the PM240 and PM250 Power Modules fulfill the latest SEMI F47-0706 standard. In the case of a voltage dip, defined in accordance with SEMI F47-0706, these drives either continue to supply a defined output current, or using an automatic restart function, continue to operate as expected.

Siemens D 11.1 2009

4/11

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Overview
The CU230P-2 Control Units are especially suitable for drives with integrated technological functions for pump, fan and compressor applications. The I/O interface, the fieldbus interfaces and the additional software functions optimally support these applications. The integration of technological functions is a significant differentiating feature to the other Control Units of the SINAMICS G120 drive family.

Example: CU230P-2 HVAC Control Unit with Intelligent Operator Panel IOP on the PM240 Power Module, frame size FSC

Selection and ordering data


Communication Digital inputs Digital outputs Analog inputs Analog outputs Designation Control Unit Order No.
new

Standard
RS485/USS; Modbus RTU PROFIBUS DP CANopen 6 6 6 3 3 3 4 4 4 2 2 2 CU230P-2 HVAC CU230P-2 DP CU230P-2 CAN 6SL3243-0BA30-1HA0 6SL3243-0BA30-1PA0 6SL3243-0BA30-1CA0

new new

Function
Closed-loop control Linear and square torque characteristics for fluid flow and positive displacement machines ECO mode for additional energy saving Vector control without encoder for sophisticated control tasks Connections Two analog inputs (current/voltage can be selected) to directly connect pressure/level sensors Two additional analog inputs to connect NI1000/PT1000 temperature sensors Direct control of valves and flaps using two 230 V relays Interfaces PROFIBUS, USS, CANopen and Modbus RTU communication Software functions Automatic restart function after power failure Flying restart Kinetic buffering (Vdc min control) PID controller for temperature, pressure, air quality, level Energy saving using the hibernation mode Load check function to monitor belts and flow Real time clock with three time generators IOP wizards for special applications such as e.g. Pumps: Positive displacement (constant load torque) and centrifugal pumps (square load torque) with and without PID controller Fans: Radial and axial fans (square load torque) with and without PID controller Compressors: Positive displacement (constant load torque) and fluid flow machines (square load torque) with and without PID controller

4/12

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Design
CU230P-2 HVAC, CU230P-2 DP, CU230P-2 CAN Control Units
Terminal No. 3 4 10 11 50 Signal Features

Analog inputs (AI)


AI0+ AI0AI1+ AI1Differential input, switchable between current, voltage Value range: 0 ... 10 V, 10 ... +10 V, 0/2 ... 10 V, 0/4 ... 20 mA Differential input, switchable between current, voltage Value range: 0 ... 10 V, 10 ... +10 V, 0/2 ... 10 V, 0/4 ... 20 mA

AI2+/NI1000 Non-isolated input, switchable between current, temperature sensors, type PT1000, NI1000 Value range: 0/4 ... 20 mA, PT1000 50 ... +250 C; NI1000 50 ... +150 C GND Reference potential of the AI2/internal electronics ground

51 52

Example: CU230P-2 DP Control Unit with open terminal covers

AI3+/NI1000 Non-isolated input for temperature sensors, Type PT1000, NI1000 Value range: PT1000 50 ... +250 C; NI1000 50 ... +150 C GND Reference potential of the AI3/internal electronics ground Non-isolated output Freely programmable Value range: 0 ... 10 V; 0/4 ... 20 mA Reference potential of the AO0/internal electronics ground Non-isolated output Freely programmable Value range: 0 ... 10 V; 0/4 ... 20 mA Reference potential of the AO1/internal electronics ground Positive input for motor temperature sensor Type: PTC, KTY sensor, Thermo-Click Negative input for motor temperature sensor Power supply output 24 V DC, max. 200 mA Reference potential of the power supply/ internal electronics ground Power supply output 10 V DC 0.5 V, max. 10 mA Reference potential of the power supply/ internal electronics ground Power supply input 18 ... 30 V DC, max. 1500 mA Reference potential of the power supply input Power supply output 10 V DC 0.5 V max. 10 mA Reference potential of the power supply/ internal electronics ground

Terminal No. 69 5 ... 8, 16.17

Signal

Features

53

Digital inputs (DI) Standard


DI Com DI0 ... DI5 Reference potential for digital inputs Freely programmable isolated, inputs in compliance with IEC 61131-2 Relay output 1 NC contact (2 A, 230 V AC) Relay output 1 NO contact (2 A, 230 V AC) Relay output 1 Common contact (2 A, 230 V AC) Relay output 2 NO contact (0.5 A, 30 V DC) Relay output 2 Common contact (0.5 A, 30 V DC) Relay output 3 NC contact (2 A, 230 V AC) Relay output 3 NO contact (2 A, 230 V AC) Relay output 3 Common contact (2 A, 230 V AC)

Analog outputs (AO)


12 AO0+

13 26

AO GND AO1+

Digital outputs (DO)


18 19 20 21 22 23 24 25 DO0, NC DO0, NO DO0, COM DO1, NO DO1, COM DO2, NC DO2, NO DO2, COM

27

AO GND

Motor temperature sensor interface


14 15 T1 motor T2 motor

Power supply
9 28 1 2 31 32 35 36 +24 V OUT GND +10 V OUT GND +24 V IN GND IN +10 V OUT GND

Siemens D 11.1 2009

4/13

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Integration
MMC IOP/IOP handheld 1 2 4.7 kOhm 3 4 AI0+ AI0+ 10 V 0V A D A 11 AI1DI0 5 6 7 DI0 DI1 D USB interface for PC tools DIP switch Analog inputs
0 to 20 mA

IOP/IOP handheld interface

10 AI1+

Digital inputs

4
+ -

5 6 7 8 16 17

ON
AI0 AI1

DI1 DI2 DI3 DI4 DI5

DI2

PC to inverter connection kit

8 DI3 16 DI4 17 DI5 9 U24V

OFF
0 to 10 V

DIP switch Bus termination ON

24 V 69

28 U0V 69 DI COM OFF 14 A 15 12 AO0+ D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC 22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0 V From external source NI1000 A CURRENT A D

PTC/KTY

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU230P-2 HVAC


DIP switch Temperature sensor NI1000

PM-IF interface

Power Module

D A D + 10 V OUT GND

RS485 connector

Temperature sensor NI1000 or AI2+ Temperature sensor NI1000 or AI3+

Voltage output 10 V

36

G_D011_EN_00210

50 AI2+/ NI1000 51 GND 52 AI3+/ NI1000 53 GND 35

1 0V 2 RS485P 3 RS485N 4 Shield 5 *

* = Not connected

CU230P-2 HVAC Control Unit connection diagram

4/14

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Integration
MMC IOP/IOP handheld 1 2 4.7 kOhm 3 4 AI0+ AI0+ 10 V 0V A D A 11 AI1DI0 DI1 DI2 DI3 DI4 DI5 5 6 7 DI0 DI1 D USB interface for PC tools DIP switch Analog inputs
0 to 20 mA

IOP/IOP handheld interface

10 AI1+

5 6 7 8 16 17

ON

Digital inputs

AI0

DI2

8 DI3 16 DI4 17 DI5 9 U24V

OFF
0 to 10 V

PROFIBUS address DIP switch ON


(1) Bit 0 (2) Bit 1 (4) Bit 2 (8) (16) (32) (64) Bit 3 Bit 4 Bit 5 Bit 6

+ 24 V 69

28 U0V 69 DI COM 14 A 15 12 AO0+ D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC 22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0 V From external source NI1000 A CURRENT A D OFF

PTC/KTY

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU230P-2 DP


DIP switch Temperature sensor NI1000

AI1

PC to inverter connection kit

PM-IF interface

Power Module

1 Shield/PE A D A D + 10 V OUT GND PROFIBUS interface SUB-D connector Temperature sensor NI1000 or AI2+ Temperature sensor NI1000 or AI3+ 50 AI2+/ NI1000 51 GND 52 AI3+/ NI1000 53 GND 35 36 2 * 3 DPB 4 RTS 5 0V 6 5V
G_D011_EN_00211

7 * 8 DPA 9 *

Voltage output 10 V

* = Not connected

CU230P-2 DP Control Unit connection diagram

Siemens D 11.1 2009

4/15

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Integration
MMC IOP/IOP handheld 1 2 4.7 kOhm 3 4 AI0+ AI0+ 10 V 0V A D A 11 AI1DI0 5 6 7 DI0 DI1 D USB interface for PC tools DIP switch Analog inputs
0 to 20 mA

IOP/IOP handheld interface

10 AI1+

Digital inputs

5 6 7 8 16 17

ON
AI0 AI1

DI1 DI2 DI3 DI4 DI5

DI2

PC to inverter connection kit

8 DI3 16 DI4 17 DI5 9 U24V

OFF
0 to 10 V

CANopen address DIP switch ON


(1) Bit 0 (2) Bit 1 (4) Bit 2 (8) (16) (32) (64) Bit 3 Bit 4 Bit 5 Bit 6

+ 24 V 69

28 U0V 69 DI COM 14 A 15 12 AO0+ D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC 22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0 V From external source OFF ON NI1000 A CURRENT A D OFF

PTC/KTY

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU230P-2 CAN


DIP switch Temperature sensor NI1000

PM-IF interface DIP switch Bus termination

Power Module

1 * A D A D + 10 V OUT GND CANopen interface SUB-D-type connector Temperature sensor NI1000 or AI2+ Temperature sensor NI1000 or AI3+ 50 AI2+/ NI1000 51 GND 52 AI3+/ NI1000 53 GND 35 36 2 CAN_L 3 CAN_GND 4 * 5 (CAN_SHLD) 6 (GND) 7 CAN_H 8 * 9 ISO (optional shield) (optional CAN ground)
G_D011_EN_00212

Voltage output 10 V

* = Not connected

CU230P-2 CAN Control Unit connection diagram

4/16

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Technical specifications
Control Unit CU230P-2 HVAC 6SL3243-0BA30-1HA0 CU230P-2 DP 6SL3243-0BA30-1PA0 CU230P-2 CAN 6SL3243-0BA30-1CA0

Electrical specifications
Operating voltage Current consumption Protective insulation Power loss 24 V DC from the Power Module or from the connection of an external power supply 18 ... 30 V DC Max. 0.5 A PELV according to EN 50178 Protective separation from the line supply using double/reinforced insulation <5.5 W 6 isolated inputs, optically isolated; free reference potential (own potential group) NPN/PNP logic can be selected using the wiring Switching level: 0 1: 11 V Switching level: 1 0: 5 V Max. input current 15 mA 2 relay change-over contacts 250 V AC 2 A (inductive load), 30 V DC 5 A (ohmic load) 1 relay NO contact 30 V DC, 0.5 A (ohmic load) 2 differential inputs, switchable between voltage and current using DIP switch: 10 ... +10 V, 0/4 ... 20 mA, 10-bit resolution 1 non-isolated input, switchable using DIP switch between current and temperature sensor, type NI1000/PT1000, 0/4 ... 20 mA; 10-bit resolution 1 non-isolated input, temperature sensor, type NI1000/PT1000, 10-bit resolution The two differential analog inputs can be configured as additional digital inputs. Switching thresholds: 0 1: Rated voltage 4 V 1 0: Rated voltage 1.6 V Analog inputs are protected against inputs in a voltage range of 30 V and have a common-mode voltage in the 15 V range. 2 non-isolated outputs, switchable between voltage and current using parameter setting: 0 ... 10 V; 0/4 ... 20 mA Voltage mode: 10 V, min. burden 10 k current mode: 20 mA, max. burden 500 The analog outputs have short circuit protection 1 motor temperature sensor input, sensors that can be connected PTC, KTY and Thermo-Click, accuracy 5 C RS485 USS Modbus RTU (switchable per software) Terminal Insulated USS: max. 187.5 kBaud Modbus RTU:19.2 kBaud bus terminating resistors can be switched in 1 MicroMemoryCard IOP supported connection options between CU230P and IOP: can be directly plugged on, door mounting or handheld BOP not possible USB PROFIBUS DP ProfiDrive profile V4.1 CANopen CANopen

Interfaces
Digital inputs Standard

Digital outputs

Analog inputs

Analog outputs

PTC/KTY interface

Bus interface
Type Protocols

Hardware

9-pin SUB-D connector Insulated Max. 12 Mbit/s Slave address can be set using DIP switches

9-pin SUB-D socket Insulated Max. 1 Mbit/s

Tool interfaces
Memory card Operator panels

PC interface V/f linear/square/parameterizable V/f with flux current control (FCC) V/f ECCO linear/square Vector control, without encoder Vector control, with encoder Torque control, without encoder Torque control, with encoder

Open-loop/closed-loop control techniques

Siemens D 11.1 2009

4/17

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU230 Control Units

Technical specifications
Control Unit CU230P-2 HVAC 6SL3243-0BA30-1HA0 16, parameterizable (4) (4) (I2t, sensor: PTC/KTY/Thermo-Click) (only with PM240 Power Module) (only with PM240 Power Module) (only with PM240 Power Module) CU230P-2 DP 6SL3243-0BA30-1PA0 CU230P-2 CAN 6SL3243-0BA30-1CA0

Software functions
Setpoint input Fixed frequencies JOG Digital motorized potentiometer (MOP) Ramp smoothing Extended ramp-function generator (with ramp smoothing Off3) Positioning down ramp Slip compensation Signal interconnection with BICO technology Free function blocks (FFB) for logic and arithmetic operations Switchable drive data sets (DDS) Switchable command data sets (CDS) Flying restart Automatic restart after line supply failure or operating fault (AR) Technology controller (internal PID) Energy-saving function (hibernation) with internal PID controller Energy-saving function (hibernation) with external PID controller Belt monitoring with and without sensor (load torque monitoring) Dry pump monitoring (load torque monitoring) Thermal motor protection Thermal inverter protection Motor identification Motor holding brake Auto-ramping (Vdcmax controller) Kinetic buffering (Vdcmax controller) Braking functions for DC braking Compound braking Dynamic braking with integrated brake chopper Degree of protection Signal cable cross-section min. max. Operating temperature Storage temperature Relative humidity Dimensions Width Height Depth Weight, approx.

Mechanical specifications and ambient conditions


IP20 0.15 mm2 (AWG28) 1.5 mm2 (AWG16) 10 ... +60 C (14 ... 140 F) 40 ... +70 C (40 ... +158 F) <95 % RH, condensation not permissible 73 mm 199 mm 65.5 mm 0.61 kg

4/18

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Overview
Safety Integrated functions The following Safety Integrated functions are integrated in the CU240S DP-F and CU240S PN-F Control Units and, with the exception of the Safe Brake Control, can be implemented without external circuit elements: The SINAMICS G120 fail-safe frequency inverter provides four safety functions, certified in accordance with EN 954-1, Category 3 and IEC 61508 SIL 2: Safe Torque Off (STO) to protect against active movement of the drive Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp Safely Limited Speed (SLS) for protection against dangerous movements when a speed limit is exceeded Safe Brake Control (SBC) for controlling motor brakes that are active in the de-energized state, e.g. motor holding brakes The functions Safe Stop 1 and Safely Limited Speed can both be implemented without having to use a motor sensor or encoder; the implementation cost is minimal. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.
Example of CU240S DP-F Control Unit

The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. Several Control Units are available in different versions: CU240E CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F

The safety functions Safely Limited Speed and Safe Stop 1 are not certified for pull-through loads as in the case of lifting gear and winders. Safety functions have been extended with firmware V3.2. Additional information is provided in the part Highlights, section Safety Integrated.

Selection and ordering data


Communication Digital inputs Standard Digital inputs Fail-safe Digital outputs Encoder interfaces Designation Control Unit Order No. 6SL3244-0BA10-0BA0 6SL3244-0BA20-1BA0 6SL3244-0BA20-1PA0 6SL3244-0BA20-1FA0 6SL3244-0BA21-1PA0 6SL3244-0BA21-1FA0

Standard
RS485/USS RS485/USS PROFIBUS DP PROFINET PROFIBUS DP PROFINET 6 9 9 9 6 6 2 2 3 3 3 3 3 3 1 1 1 1 1 CU240E CU240S CU240S DP CU240S PN CU240S DP-F CU240S PN-F

Fail-safe for Safety Integrated

Siemens D 11.1 2009

4/19

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Design
CU240E Control Unit
Terminal No. 5 8, 16.17 18 19 20 21 Signal DI0 DI5 Features Freely programmable (isolated) 5.5 mA/24 V Relay output 1 NC contact (0.5 A, 30 V DC) Relay output 1 NO contact (0.5 A, 30 V DC) Relay output 1 Common contact (0.5 A, 30 V DC) Relay output 2 NO contact (0.5 A, 30 V DC) Relay output 2 Common contact (0.5 A, 30 V DC) Relay output 3 NC contact (0.5 A, 30 V DC) Relay output 3 NO contact (0.5 A, 30 V DC) Relay output 3 Common contact (0.5 A, 30 V DC) 0 10 V, 10 +10 V, 0/2 10 V or 0/4 20 mA 0 10 V, 0 20 mA

Digital inputs (DI)

Digital outputs (DO)


DO0, NC DO0, NO DO0, COM DO1, NO DO1, COM DO2, NC DO2, NO DO2, COM

22 23 24 25

Analog inputs (AI)


CU240E Control Unit without terminal cover 3 4 10 11 12 AI0+ AI0AI1+ AI1AO0+ Freely programmable (0/4 20 mA with max. 500 , 0/2 10 V with min. 500 ) M Freely programmable (0/4 20 mA with max. 500 ) M Positive PTC/KTY input Negative PTC/KTY input RS485 A, USS protocol RS485 B, USS protocol Isolated user power supply +24 V at 100 mA Isolated user reference voltage Non-isolated, regulated 10 V power supply for I/O max. 10 mA Power supply reference

Analog outputs (AO)

13 26 27 14 15 29 30

AO0AO1+ AO1PTC+ PTCP+ NU 24 V U0V +10 V

PTC/KTY interface

Serial RS485 interface

Power supply
9 28 1

0V

4/20

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Design
CU240S, CU240S DP, CU240S DP-F, CU240S PN and CU240S PN-F Control Units
Terminal No. 3 4 10 11 12 Signal AI0+ AI0AI1+ AI1AO0+ Freely programmable (0/4 20 mA with max. 500 , 0/2 10 V with min. 500 ) M Freely programmable (0/4 20 mA with max. 500 ) M Encoder AP Channel A non-inverting input Encoder AN Channel A inverting input Encoder BP Channel B non-inverting input Encoder BN Channel B inverting input Encoder ZP Zero pulse non-inverting input Encoder ZN Zero pulse inverting input Positive PTC/KTY input Negative PTC/KTY input Isolated encoder power supply (+24 V at 100 mA, +5 V at 300 mA), configured using DIP switch Isolated user power supply +24 V at 100 mA Isolated encoder power supply and user reference voltage Non-isolated, regulated 10 V power supply for I/O max. 10 mA Power supply reference 24 V power supply input 24 V power supply reference Features 0 10 V, 10 +10 V, 0/2 10 V or 0/4 20 mA 0 10 V, 0 20 mA

Analog inputs (AI)

Analog outputs (AO)

13 26 27 70 71 72 73 Example: CU240S DP-F Control Unit (right without terminal cover, with pluggable terminals) 74 75 Terminal No. 5 8, 16.17 40 42 (only for CU240S, CU240S DP and CU240S PN) Signal DI0 DI5 DI6 DI8 Features

AO0AO1+ AO1ENC AP ENC AN ENC BP ENC BN ENC ZP ENC ZN

Encoder interface

Digital inputs (DI) Standard


Freely programmable (isolated) 5.5 mA/24 V Freely programmable (isolated) 5.5 mA/24 V

PTC/KTY interface
14 15 PTC+ PTCENC+ line supply U 24 V U0V +10 V

Power supply
33

9 28 1

Digital inputs (DI) Fail-safe (for CU240S DP-F and CU240S PN-F only)
60 63 (for CU240S DP-F and CU240S PN-F only) 18 19 20 21 22 23 24 25 FDI0A FDI0B FDI1A FDI1B Fail-safe digital inputs, 2 channels (redundant), freely programmable (isolated) 5.5 mA/24 V

2 31 Relay output 1 NC contact (0.5 A, 30 V DC) Relay output 1 NO contact (0.5 A, 30 V DC) Relay output 1 Common contact (0.5 A, 30 V DC) Relay output 2 NO contact (0.5 A, 30 V DC) Relay output 2 Common contact (0.5 A, 30 V DC) Relay output 3 NC contact (0.5 A, 30 V DC) Relay output 3 NO contact (0.5 A, 30 V DC) Relay output 3 Common contact (0.5 A, 30 V DC) 32 DO0, NC DO0, NO DO0, COM DO1, NO DO1, COM DO2, NC DO2, NO DO2, COM

0V +24 V 0V

Digital outputs (DO)

Siemens D 11.1 2009

4/21

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Integration

1 2 4.7 kOhm 3 4 AI0+ AI0-

BOP + 10 V 0V A D
JOG

RS232/BOP interface

10 AI1+

4
DI0 DI1 DI2 DI3 DI4 DI5 5 6 7 8 16 17

A 11 AI1D ON 5 6 7 DI0

DIP switch for analog inputs


0 to 20 mA

RS232 with PC to inverter connection kit

AI0

Digital inputs

DI1 DI2

OFF
0 to 10 V

8 DI3 16 DI4 17 DI5

+ 24 V 28

U24V

28 U0V

14 PTC+ PTC/KTY A 15 PTC12 AO0+ 0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC PM-IF interface Low voltage only (30 V, 500 mA) 22 COM DO1 21 NO 25 COM DO2 24 NO
G_D011_EN_00183

Control Unit CU240E

AI1

Power Module

23 NC 29 30
RS485

CU240E Control Unit connection diagram

4/22

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Integration
MMC BOP + 10 V 0V AI0+ AI0AA/ DD AA/ DD ON RS232/BOP interface
I FN
JOG

1 2 4.7 kOhm 3 4

10 AI1+ 11 AI1DI0 DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 5 6 7 8 16 17 40 41 42 5 6 7 DI0 DI1 DI2 General I/O DIP switch
0 to 20 mA

24 V encoder supply 5 V encoder supply Encoder A termination Encoder B termination Encoder Z termination

RS232 with PC to inverter connection kit

AI0

Digital inputs

8 DI3 16 DI4 17 DI5 40 DI6 41 DI7 42 DI8 9 U24V

OFF
0 to 10 V

Bus termination DIP switch ON

+ 24 V

28

28 U0V ENC+ 33 Line 14 PTC+ A 15 PTC12 AO0+ D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC A A D

OFF

PTC/KTY

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU240S

AI1

PM-IF interface Low voltage only (30 V, 500 mA) 22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0V From external source 1 *

Power Module

RS485 interface SUB-D-type connector

70 ENC AP

2 * 3 RS485P 4 * 5 0V 6 *
G_D011_EN_00114a

72 ENC BP 73 ENC BN 74 ENC ZP 75 ENC ZN

Encoder interface

71 ENC AN

7 * 8 RS485N 9 *

* = Not connected

CU240S Control Unit connection diagram

Siemens D 11.1 2009

4/23

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Integration
MMC BOP + 10 V 0V AI0+ AI0AA/ DD AA/ DD ON RS232/BOP interface
I FN
JOG

1 2 4.7 kOhm 3 4

10 AI1+ 11 AI1DI0 5 6 7 8 16 17 40 41 42 5 6 7 DI0 DI1 DI2 General I/O DIP switch


0 to 20 mA

AI0

DI2 DI3 DI4 DI5 DI6 DI7 DI8

Digital inputs

8 DI3 16 DI4 17 DI5 40 DI6 41 DI7 42 DI8 9 U24V

OFF
0 to 10 V

PROFIBUS address DIP switch ON


(1) Bit 0 (2) Bit 1 (4) Bit 2 (8) (16) (32) (64) Bit 3 Bit 4 Bit 5 Bit 6

+ 24 V

OFF

28

28 U0V ENC+ 33 Line 14 PTC+ A 15 PTC12 AO0+ D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC PM-IF interface A A D

PTC/KTY

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU240S DP

AI1

DI1

24 V encoder supply 5 V encoder supply Encoder A termination Encoder B termination Encoder Z termination

RS232 with PC to inverter connection kit

Low voltage only (30 V, 500 mA)

22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0V From external source 1 Shield

Power Module

PROFIBUS interface SUB-D-type connector

70 ENC AP

2 U0V 3 RxD/TxD-P 4 CNTR-P 5 DGND 6 VP


G_D011_EN_00101

72 ENC BP 73 ENC BN 74 ENC ZP 75 ENC ZN

Encoder interface

71 ENC AN

7 U24V 8 RxD/TxD-N 9 *

* = Not connected

CU240S DP Control Unit connection diagram

4/24

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Integration
MMC BOP + 10 V 0V A D A D General I/O DIP switch
0 to 20 mA

1 2 4.7 kOhm 3 AI0+ 4 AI010 AI1+ 11 AI1DI0 DI1 DI2 DI3 DI4 DI5 DI6 5 6 7 8 16 17 40 60 61 62 63 28 5 DI0

RS232/BOP interface

FN
JOG

24 V encoder supply 5 V encoder supply Encoder A termination Encoder B termination Encoder Z termination

RS232 with PC to inverter


connection kit

AI0

7 DI2 8 DI3 16 DI4 17 DI5 9 U24V

Standard digital inputs

0 to 10 V

PROFIBUS address DIP switch


(1) (2) (4) (8) (16) (32) (64)

Safety digital inputs

Bit 0

Bit 1

AI1

6 DI1

Bit 2

Bit 3

Bit 4

Bit 5

60 61 62 63

FDI FDI FDI FDI

0A 0B 1A 1B

+ 24 V -

28 U0V ENC+ 33 Line 14 PTC+ A D D A D A

PTC/KTY

15 PTC12 AO0+

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU240S DP-F

13 AO026 AO1+ 27 AO120 COM DO0 19 NO 18 NC

Bit 6

Low voltage only (30 V, 500 mA)

22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0V From external source

PM-IF interface

Power Module

1 shield

PROFIBUS interface SUB-D-type connector

70 ENC AP Encoder interface 71 ENC AN 72 ENC BP 73 ENC BN 74 ENC ZP 75 ENC ZN

2 U0V 3 RxD/TxD-P 4 CNTR-P 5 DGND 6 VP 7 U24V 8 RxD/TxD-N 9 *


G_D011_EN_00102b

* = Not connected

CU240S DP-F Control Unit connection diagram

Siemens D 11.1 2009

4/25

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Integration
MMC BOP + 10 V 0V AI0+ AI0AA/ DD AA/ DD ON RS232/BOP interface
I FN
JOG

1 2 4.7 kOhm 3 4

10 AI1+ 11 AI1DI0 5 6 7 8 16 17 40 41 42 5 6 7 DI0 DI1 DI2 General I/O DIP switch


0 to 20 mA

AI0

DI2 DI3 DI4 DI5 DI6 DI7 DI8

Digital inputs

8 DI3 16 DI4 17 DI5 40 DI6 41 DI7 42 DI8 9 U24V

OFF
0 to 10 V

+ 24 V

28

28 U0V ENC+ 33 Line 14 PTC+ A 15 PTC12 AO0+ D 13 AO026 AO1+ D 27 AO120 COM DO0 19 NO 18 NC PM-IF interface A A D

PTC/KTY

0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

Control Unit CU240S PN

AI1

DI1

24 V encoder supply 5 V encoder supply Encoder A termination Encoder B termination Encoder Z termination

RS232 with PC to inverter connection kit

Low voltage only (30 V, 500 mA)

22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0V From external source 1 TX+ 70 ENC AP 2 TX3 RX+

Power Module

Encoder interface

PROFINET interface RJ45

71 ENC AN 72 ENC BP 73 ENC BN 74 ENC ZP 75 ENC ZN

4 * 5 * 6 RXG_D011_EN_00119

7 * 8 *

* = Not connected

CU240S PN Control Unit connection diagram

4/26

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Integration
MMC BOP + 10 V 0V A D A D ON General I/O DIP switch
0 to 20 mA

1 2
4.7 kOhm

3 AI0+ 4 AI010 AI1+ 11 AI1-

RS232/BOP interface

FN
JOG

5 6 7 8 16 17 40 60 61 62 63 28

24 V encoder supply 5 V encoder supply Encoder A termination Encoder B termination Encoder Z termination

DI0 DI1 DI2 DI3 DI4 DI5 DI6

5 DI0

Standard digital inputs

7 DI2 8 DI3 16 DI4 17 DI5 9 U24V 60 61 62 63 FDI FDI FDI FDI 0A 0B 1A 1B

OFF
0 to 10 V

+ 24 V -

28 U0V ENC+ 33Line 14 PTC+ A D D A D A

Safety digital inputs

PTC/KTY 0 to 20 mA max. 500 Ohm 0 to 20 mA max. 500 Ohm

15 PTC12 AO0+ 13 AO026 AO1+ 27 AO120 COM DO0 19 NO 18 NC

Control Unit CU240S PN-F

AI0

AI1

6 DI1

RS232 with PC to inverter connection kit

PM-IF interface
Low voltage only (30 V, 500 mA)

22 COM DO1 21 NO 25 COM DO2 24 NO 23 NC 31 +24 V 32 0V From external source 1 TX+ PROFIBUS interface RJ45 70 ENC AP 71 ENC AN 72 ENC BP 73 ENC BN 74 ENC ZP 75 ENC ZN Encoder interface 2 TX3 RX+ 4 * 5 * 6 RX8 *
G_D011_EN_00184b

Power Module

7 *

* = Not connected

CU240S PN-F Control Unit connection diagram

Siemens D 11.1 2009

4/27

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Technical specifications
Control Unit CU240E 6SL32440BA10-0BA0 24 V DC via the Power Module CU240S 6SL32440BA20-1BA0 CU240S DP 6SL32440BA20-1PA0 CU240S PN 6SL32440BA20-1FA0 CU240S DP-F 6SL32440BA21-1PA0 CU240S PN-F 6SL32440BA21-1FA0 24 V DC via the Power Module or external 24 V DC Max. 0.7 A < 17 W 6 2 3 2

Electrical specifications
Operating voltage 24 V DC via the 24 V DC via the 24 V DC via the 24 V DC via the Power Module or Power Module or Power Module or Power Module or external 24 V DC external 24 V DC external 24 V DC external 24 V DC Max. 0.5 A < 5.5 W 9 3 2 Max. 0.5 A < 5.5 W 9 3 2 Max. 0.7 A < 13 W 9 3 2 Max. 0.7 A < 16 W 6 2 3 2

Current drain from the 24 V supply Power loss (full load)

Available soon < 5.5 W 6 3 2

Interfaces
Digital inputs Standard Digital inputs Fail-safe

Digital outputs Analog inputs

Both analog inputs can be configured as supplementary digital inputs if an additional function is required. Switching thresholds: 0 1: Rated voltage 2 V 1 0: Rated voltage 0.8 V Analog inputs are protected against inputs in a voltage range of 30 V and have a common-mode voltage in the 15 V range. Analog outputs 2 2 2 2 2 2 Analog outputs have short-circuit protection, but are not isolated. Maximum output voltage = 10 V in the current mode, maximum output current = 20 mA in the voltage mode. The response time should be approximately 1 ms at a load of max. 10 k in the voltage mode. Bus interface Encoder interfaces PTC/KTY interface Brake Relay interface or Safe Brake Relay interface (connected via Power Module) MMC memory card slot Operator panels that can be used RS485/USS RS485/USS 1 PROFIBUS DP 1 PROFINET 1 PROFIBUS DP, PROFIsafe 1 PROFINET, PROFIsafe 1

BOP, IOP Handheld (via PC Inverter Connection Kit)

BOP, IOP Handheld (via PC Inverter Connection Kit)

BOP, IOP Handheld (via PC Inverter Connection Kit)

BOP, IOP Handheld (via PC Inverter Connection Kit)

BOP, IOP Handheld (via PC Inverter Connection Kit)

BOP, IOP Handheld (via PC Inverter Connection Kit)

RS232/USS interface (connection via PC Inverter Connection Kit)

Safety functions
Integrated safety functions acc. to Category 3 of EN 954-1 and acc. to SIL 2 of IEC 61508 Safe Stop 1 (SS1) Safely Limited Speed (SLS) Safe Brake Control (SBC) Safe Torque Off (STO)

Open-loop/closed-loop control techniques


V/f linear/square/parameterizable V/f with flux current control (FCC) Vector control, without encoder Vector control, with encoder Torque control, without encoder Torque control, with encoder

4/28

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
CU240 Control Units

Technical specifications
Control Unit CU240E 6SL32440BA10-0BA0 CU240S 6SL32440BA20-1BA0 CU240S DP 6SL32440BA20-1PA0 CU240S PN 6SL32440BA20-1FA0 CU240S DP-F 6SL32440BA21-1PA0 CU240S PN-F 6SL32440BA21-1FA0

Software functions
Fixed frequencies Signal interconnection with BICO technology Automatic restart after line supply failure or operational fault Positioning down ramp Slip compensation 16, 16, 16, 16, 16, 16, parameterizable parameterizable parameterizable parameterizable parameterizable parameterizable (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240) (only with PM240)

Free function blocks (FFB) for logic and arithmetic operations Ramp smoothing 3 selectable drive data sets 3 selectable command data sets (CDS) (manual/auto) Flying restart JOG Technology controller (PID) Thermal motor protection Thermal inverter protection Setpoint input Motor identification Motor holding brake Vdcmax controller (only with PM240) (only with PM240) (only with PM240)

Kinetic buffering

Braking functions for DC braking Compound braking Dynamic braking with integrated brake chopper Degree of protection Signal cable cross-section min. max. Operating temperature Storage temperature Relative humidity

Mechanical specifications and ambient conditions


IP20 IP20 IP20 IP20 IP20 IP20

0.05 mm2 0.05 mm2 0.05 mm2 0.05 mm2 0.05 mm2 0.05 mm2 (AWG30) (AWG30) (AWG30) (AWG30) (AWG30) (AWG30) 2 mm2 (AWG14) 2 mm2 (AWG14) 2 mm2 (AWG14) 2 mm2 (AWG14) 2 mm2 (AWG14) 2 mm2 (AWG14) 10 +50 C (14 122 F) 10 +50 C (14 122 F) 10 +50 C (14 122 F) 10 +50 C (14 122 F) 0 45 C (32 113 F) 0 40 C (32 104 F)

40 +70 C 40 +70 C 40 +70 C 40 +70 C 40 +70 C 40 +70 C (40 +158 F) (40 +158 F) (40 +158 F) (40 +158 F) (40 +158 F) (40 +158 F) < 95 % RH, condensation not permissible 73 mm 195 mm 31 mm 0.21 kg < 95 % RH, condensation not permissible 73 mm 177 mm 63 mm 0.52 kg < 95 % RH, condensation not permissible 73 mm 177 mm 63 mm 0.52 kg < 95 % RH, condensation not permissible 73 mm 177 mm 63 mm 0.52 kg < 95 % RH, condensation not permissible 73 mm 177 mm 63 mm 0.52 kg < 95 % RH, condensation not permissible 73 mm 177 mm 63 mm 0.52 kg

Dimensions Width Height Depth Weight, approx.

Siemens D 11.1 2009

4/29

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Overview

4
Example: SINAMICS G120, frame sizes FSA to FSF

The PM240 Power Module can be used to couple the DC links of up to 10 Power Modules. This functionality is used for applications such as safe power-down after power failure or kinetic buffering (the DC link is supplied in the generator mode with the kinetic energy of the load so that the DC link voltage can be maintained). The PM240 Power Module is also designed for safety-oriented applications. In conjunction with a Fail-safe Control Unit, the drive can be turned into a Safety Integrated Drive (see Control Units). The permissible cable lengths between inverter and motor are limited. Longer cables can be used if output reactors are connected (see load-side power components). Line reactors are available to minimize line harmonics (see lineside components). Frame size FSA of the PM240 Power Module is available only without integrated line filter to class A. A base filter is therefore available so that class A can be achieved. A class B base filter is also available so that class B can be achieved (see line-side power components). Frame sizes FSB and FSC of the PM240 Power Module are available both with and without integrated class A line filter. For compliance with class B, PM240 Power Modules with integrated class A line filter must be fitted additionally with a class B base filter (see line-side components). Power Modules with integrated class A line filter are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded (TN, TT) and non-grounded (IT) supply systems.

Example: SINAMICS G120, frame size FSGX

PM240 Power Modules, frame sizes FSA to FSF have an integrated brake chopper to which an external braking resistor can be connected via terminals DCP/R1 and R2 (see DC link components). PM240 Power Modules, frame size FSGX do not have an integrated brake chopper. For these devices, there is an optional pluggable braking module to connect a braking resistor.

4/30

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Selection and ordering data


To ensure that a suitable Power Module is selected, the following currents should be used for applications: rated output current for applications with light overload (LO) base load current for applications with high overload (HO)
Rated power 1) Rated output current2) Irated A 1.3 1.7 2.2 3.1 4.1 5.9 7.7 10.2 18 25 32 38 45 60 75 90 110 145 178 205 250 302 370 477 Power based on the base load current 3) kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 110 132 160 200 hp 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 Base load current 3) IH A 1.3 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 19 26 32 38 45 60 75 90 110 145 178 205 250 302 370 FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF FSF FSF FSGX FSGX FSGX
new new new

With reference to the rated output current, the modules support at least 2-pole to 6-pole low-voltage motors, e.g. the new 1LE1 motor series (please refer to the Appendix for further information). The rated power is merely a guide value. For a description of the overload performance, please refer to the general technical specifications of the Power Modules.
SINAMICS G120 PM240 Power Module without integrated line filter Order No. 6SL3224-0BE13-7UA0 6SL3224-0BE15-5UA0 6SL3224-0BE17-5UA0 6SL3224-0BE21-1UA0 6SL3224-0BE21-5UA0 6SL3224-0BE22-2UA0 6SL3224-0BE23-0UA0 6SL3224-0BE24-0UA0 6SL3224-0BE25-5UA0 6SL3224-0BE27-5UA0 6SL3224-0BE31-1UA0 6SL3224-0BE31-5UA0 6SL3224-0BE31-8UA0 6SL3224-0BE32-2UA0 6SL3224-0BE33-0UA0 6SL3224-0BE33-7UA0 6SL3224-0BE34-5UA0 6SL3224-0BE35-5UA0 6SL3224-0BE37-5UA0 6SL3224-0BE38-8UA0 6SL3224-0BE41-1UA0 6SL3224-0XE41-3UA0 6SL3224-0XE41-6UA0 6SL3224-0XE42-0UA0 SINAMICS G120 PM240 Power Module with integrated class A line filter Order No. 6SL3224-0BE22-2AA0 6SL3224-0BE23-0AA0 6SL3224-0BE24-0AA0 6SL3224-0BE25-5AA0 6SL3224-0BE27-5AA0 6SL3224-0BE31-1AA0 6SL3224-0BE31-5AA0 6SL3224-0BE31-8AA0 6SL3224-0BE32-2AA0 6SL3224-0BE33-0AA0 6SL3224-0BE33-7AA0 6SL3224-0BE34-5AA0 6SL3224-0BE35-5AA0 6SL3224-0BE37-5AA0

Frame size

kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 110 132 160 200 250

hp 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.0 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400

380 ... 480 V 3 AC

1) 2)

Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for light overload (LO). The rated output current Irated is based on the duty cycle for light overload (LO). These current values are valid for 400 V and are stamped on the rating plate of the Power Module.

3)

The base load current IH is based on the duty cycle for high overload (HO).

Siemens D 11.1 2009

4/31

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Integration
PM240 Power Modules communicate with the Control Unit via the PM-IF interface. PM240 Power Modules have the following interfaces as standard: PM-IF interface to connect the PM240 Power Module to the Control Unit. The PM240 Power Module also supplies power to the Control Unit using an integrated power supply Terminals DCP/R1 and R2 for connection of an external braking resistor, valid up to frame size FSF. For frame size FSGX, an external plug-in braking unit (Braking Module) is required to connect a braking resistor Motor connection using screw terminals or screw studs Control for the Brake Relay or the Safe Brake Relay for controlling a motor brake 2 PE/protective conductor connections

ext. 24 V DC or via Power Module required 24 V 0V

380 V to 480 V 3 AC L1 L2 L3 PE

4
PE U1/ L1 V1/ W1/ L2 L3 Line filter class A 3~

Power Module PM240

= DCP/R1 Control Unit PM-IF Interface R2 DCN Braking resistor 1)

3 ~

PE U2

V2

W2

Brake Relay
1) For

frame size FSGX a Braking Module is required for connecting a braking resistor Motor brake

M 3 ~

PM240 Power Module connection diagram with or without integrated class A line filter

4/32

Siemens D 11.1 2009

G_D011_EN_00100b

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Integration
Power and DC link components which are optionally available depending on the Power Module used The following line-side power components, DC link components and load-side power components are optionally available in the appropriate frames sizes for the Power Modules:
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


F/S 1) S S S S S 1) S S I (Option) S S

Available frame sizes Line filter, class A Line filter, class B Line reactor DC link components Braking resistor Braking Module Output reactor Sine-wave filter U S I F = = = = =

Line-side power components U U U U U U F U U U U U F U U S U U F U S S S F U S S S

Load-side power components

Base component Lateral mounting Integrated Not possible Power Modules available with and without integrated class A filter

1)

PM240 FSF Power Modules from 110 kW (150 hp) and higher and FSGX are only available without an integrated class A filter. An optional class A line filter for side mounting is available instead.

Siemens D 11.1 2009

4/33

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Integration
Many system components for PM240 Power Modules are designed as base components, that is, the component is mounted on the baseplate and the PM240 Power Module above it in a space-saving design. Up to two base components can be mounted above one another. The following diagram shows the basic layout of a PM240 Power Module with line reactor as base component. On the line side, the line-side reactors have terminals and on the Power Module side, they have a pre-fabricated cable. For frame sizes FSA to FSC, when installed, the line terminals are at the top, for frame sizes FSD to FSE they are at the bottom.
Power supply Power module Line reactor Output reactor or sine-wave filter

Power supply

Power module

Line reactor

to the motor

G_D211_EN_00078a

PM240 Power Module frame size FSA with line reactor and output reactor or sine-wave filter

For configurations involving more than two base-type system components, e.g. line filter + line reactor + output reactor, individual components must be mounted to the side of the Power Modules. In this case, the line reactor and line filter must be installed under the Power Module and the output reactor to the righthand side.
Line reactor Output reactor or sine-wave filter

Basic layout of a PM240 Power Module with line reactor as base component

Power Modules, from frame size FSB and higher are available with integrated class A line filters (an external class A line filter is not required in this case).

Power module

Line filter

Line reactor

Power supply

to the motor

PM240 Power Module frame size FSA with line reactor, line filter and output reactor or sine-wave filter
G_D211_EN_00079a

Power supply

PM240 Power Module frame size FSA with line reactor and class A line filter

4/34

Siemens D 11.1 2009

G_D011_EN_00186

If a class A line filter is installed in addition to the line reactor on frame size FSA, the components must be arranged as shown in the diagram below. In this case, the line connection is from below.

Power module

Line filter

G_D011_EN_00185

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Integration
Maximum permissible cable lengths from the motor to the inverter when using output reactors or sine-wave filters depending on the voltage range The following load-side power components are optionally available in the appropriate frame sizes and result in the following maximum cable lengths:
Maximum permissible motor cable lengths (shielded/unshielded) in m Frame sizes FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


50/100 150/225 100/150 150/225 100/150 50/100 200/300 200/300 200/300 200/300 100/100 200/300 200/300 200/300 200/300 150/150 200/300 200/300 200/300 200/300 300/450 300/450 300/450 300/450 300/450

Available frame sizes With optional output reactor at 380 V (10 %) to 400 V 3 AC at 401 V to 480 V (+10 %) 3 AC With optional sine-wave filter at 380 V (10 %) to 400 V 3 AC at 401 V to 480 V (+10 %) 3 AC

50/100 150/225 100/150 150/225 100/150

Without output reactor/sine-wave filter 50/100 150/225 100/150 150/225 100/150

Derating data The following inverter output currents can still be implemented for long motor cables without output reactor and sine-wave filter. Derating for PM240 Power Modules, frame sizes FSA to FSF for shielded motor cables. From frame size FSD and higher, only the particular main Power Module types were tested. The values also apply to the other Power Modules of the particular frame size.

Rated power (at IH) kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0 22.0 37.0 75.0 hp 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.0 7.5 10 15 30 50 100

Frame size

Base load current IH A

Rated current Motor conCurrent derating Irated nection cross- of the output current as a % of the base load current section for the cable lengths (MOTION-CONNECT) A mm2 1.3 1.7 2.2 3.1 4.1 5.9 7.7 10.2 18 25 32 60 90 178 2.5 2.5 2.5 2.5 2.5 6 6 6 10 10 10 35 35 95 50 m 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 % 100 m 60 % 60 % 70 % 70 % 90 % 90 % 95 % 100 % 100 % 150 m 45 % 80 % 80 % 90 % 95 % 100 % 200 m 85 % 90 % 95 %

FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSE FSF

1.3 1.7 2.2 3.1 4.1 5.9 7.7 10.2 13.2 19 26 45 75 145

Not possible

Siemens D 11.1 2009

4/35

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Technical specifications
General technical specifications
PM240 Power Modules System operating voltage Line supply requirements Line short circuit voltage uK Input frequency Output frequency Control type V/f Control type Vector Pulse frequency 380 480 V 3 AC 10 % at uK > 1 %, a line reactor is recommended 47 63 Hz 0 650 Hz 0 200 Hz to 75 kW HO: 4 kHz from 90 kW HO: 2 kHz for higher pulse frequencies up to 16 kHz see the derating data 0.7 0.85 95 97 % 93 %

Power factor Inverter efficiency Modulation depth Overload capability High overload (HO) - 0.37 ... 75 kW - 90 ... 200 kW Light overload (LO) - 0.37 ... 250 kW Electromagnetic compatibility Possible braking methods

1.5 rated output current (i.e. 150 % overload) for 57 s with a cycle time of 300 s 2 rated output current (i.e. 200 % overload) for 3 s with a cycle time of 300 s 1.36 rated output current (i.e. 136 % overload) for 57 s with a cycle time of 300 s 1.6 rated output current (i.e. 160 % overload) for 3 s with a cycle time of 300 s 1.1 rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s 1.5 rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s Optional class A or B line filter acc. to EN 55011 is available DC braking Compound braking Dynamic braking with integrated brake chopper (optional for frame size FSGX) IP20

Degree of protection Operating temperature High overload (HO) - Frame sizes FSD to FSF - Frame size FSGX Light overload (LO) Storage temperature Relative humidity Cooling Installation altitude

0 50 C (32 122 F) without derating, > 50 60 C see derating characteristics 0 40 C (32 104 F) without derating, > 40 55 C see derating characteristics 0 40 C (32 104 F) without derating, > 40 60 C (> 40 55 C for frame size FSGX) see derating characteristics 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible Internal air cooling, power units with increased air cooling using integrated fans up to 1000 m above sea level without power reduction, > 1000 m see derating characteristics

Standard SCCR (Short Circuit Cur- FSA, FSB, FSC: 10 kA rent Rating) 1) FSD, FSE, FSF, FSGX: 42 kA Protection functions Undervoltage Overvoltage Overcontrol/overload Ground fault Short circuit Stall protection Motor blocking protection Motor overtemperature Inverter overtemperature Parameter locking UL, cUL, CE, c-tick, SEMI F47 According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC

Standards conformance CE mark

1)

Applies to industrial control cabinet installations to NEC Article 409/UL 508A. For further information, visit us on the Internet at: http://support.automation.siemens.com/WW/view/en/23995621

4/36

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Rated input current 3) with line reactor without line reactor Max. length of cable to brake resistor Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section kW m3/s dB A PM240 Power Modules 6SL32240BE13-7UA0 6SL32240BE15-5UA0 6SL32240BE17-5UA0 6SL32240BE21-1UA0 6SL32240BE21-5UA0

A A A A

1.3 1.3 1.3 2.6

1.7 1.7 1.7 3.4 0.55 (0.75) 0.55 (0.75) 4 0.97 0.1 0.005 < 45 1

2.2 2.2 2.2 4.4 0.75 (1.0) 0.75 (1.0) 4 0.97 0.1 0.005 < 45 1

3.1 3.1 3.1 6.2 1.1 (1.5) 1.1 (1.5) 4 0.97 0.1 0.005 < 45 1

4.1 4.1 4.1 8.2 1.5 (2.0) 1.5 (2.0) 4 0.97 0.11 0.005 < 45 1

kW (hp) 0.37 (0.5) kW (hp) 0.37 (0.5) kHz 4 0.97 0.09 0.005 < 45 1

A A m

1.4 1.7 15 Screw terminals

1.8 2.1 15 Screw terminals 1 2.5 Screw terminals 1 2.5 Screw terminals

2.3 2.6 15 Screw terminals 1 2.5 Screw terminals 1 2.5 Screw terminals

3.2 3.9 15 Screw terminals 1 2.5 Screw terminals 1 2.5 Screw terminals

4.3 4.9 15 Screw terminals 1 2.5 Screw terminals 1 2.5 Screw terminals

mm2

1 2.5 Screw terminals

mm2

1 2.5 Screw terminals

DC link connection, connection for the braking resistor DCP/R1, DCN, R2 Conductor cross-section mm2 PE connection Motor cable length 4), max. Shielded m Unshielded m Degree of protection Dimensions Width Height Depth - without Control Unit - with Control Unit Frame size Weight, approx. kg mm mm mm mm

1 2.5 On housing with M4 screw 50 100 IP20 73 173 145 210 FSA 1.1

1 2.5 On housing with M4 screw 50 100 IP20 73 173 145 210 FSA 1.1

1 2.5 On housing with M4 screw 50 100 IP20 73 173 145 210 FSA 1.1

1 2.5 On housing with M4 screw 50 100 IP20 73 173 145 210 FSA 1.1

1 2.5 On housing with M4 screw 50 100 IP20 73 173 145 210 FSA 1.1

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and line impedance. The input currents apply for a load at rated power (based on Irated) for a line impedance corresponding to uK = 1 %. These current values without line reactor are stamped on the rating plate of the Power Module. Max. motor cable length 25 m (shielded) for PM240 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

Siemens D 11.1 2009

4/37

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Rated input current 3) with line reactor without line reactor Max. length of cable to braking resistor Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section kW m3/s dB A PM240 Power Modules 6SL32240BE22-2UA0 6SL32240BE22-2AA0 6SL32240BE23-0UA0 6SL32240BE23-0AA0 6SL32240BE24-0UA0 6SL32240BE24-0AA0 6SL32240BE25-5UA0 6SL32240BE25-5AA0 6SL32240BE27-5UA0 6SL32240BE27-5AA0

A A A A

5.9 5.9 5.9 11.8

7.7 7.7 7.7 15.4 3 (4) 3 (4) 4 0.95 0.16 0.024 < 50 1

10.2 10.2 10.2 20.4 4 (5) 4 (5) 4 0.95 0.18 0.024 < 50 1

18 18 13.2 26.4 7.5 (10) 5.5 (7.5) 4 0.95 0.24 0.055 < 60 1

25 25 19 38 11 (15) 7.5 (10) 4 0.95 0.30 0.055 < 60 1

kW (hp) 2.2 (3.0) kW (hp) 2.2 (3.0) kHz 4 0.95 0.14 0.024 < 50 1

A A m

6.1 7.6 15 Screw terminals

8 10.2 15 Screw terminals 16 Screw terminals 16 Screw terminals

10.4 13.4 15 Screw terminals 16 Screw terminals 16 Screw terminals

18.7 21.9 15 Screw terminals 2.5 10 Screw terminals 2.5 10 Screw terminals

26 31.5 15 Screw terminals 2.5 10 Screw terminals 2.5 10 Screw terminals

mm2

16 Screw terminals

mm2

16 Screw terminals

DC link connection, connection for the braking resistor DCP/R1, DCN, R2 Conductor cross-section mm2 PE connection Motor cable length 4), max. Shielded m m Unshielded Degree of protection Dimensions Width Height Depth - without Control Unit - with Control Unit Frame size Weight, approx. kg mm mm mm mm

16 On housing with M5 screw 50 100 IP20 153 270 165 230 FSB 4

16 On housing with M5 screw 50 100 IP20 153 270 165 230 FSB 4

16 On housing with M5 screw 50 100 IP20 153 270 165 230 FSB 4

2.5 10 On housing with M5 screw 50 100 IP20 189 334 185 250 FSC 7

2.5 10 On housing with M5 screw 50 100 IP20 189 334 185 250 FSC 7

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and line impedance. The input currents apply for a load at rated power (based on Irated) for a line impedance corresponding to uK = 1 %. These current values without line reactor are stamped on the rating plate of the Power Module. Max. motor cable length 25 m (shielded) for PM240 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

4/38

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Rated input current3) with line reactor without line reactor Max. length of cable to braking resistor Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section kW m3/s dB A PM240 Power Modules 6SL32240BE31-1UA0 6SL32240BE31-1AA0 6SL32240BE31-5UA0 6SL32240BE31-5AA0 6SL32240BE31-8UA0 6SL32240BE31-8AA0 6SL32240BE32-2UA0 6SL32240BE32-2AA0 6SL32240BE33-0UA0 6SL32240BE33-0AA0

A A A A

32 32 26 52

38 38 32 64 18.5 (25) 15 (20) 4 > 0.97 0.42 0.055 < 60 1

45 45 38 76 22 (30) 18.5 (25) 4 > 0.97 0.52 0.055 < 60 1

60 60 45 90 30 (40) 22 (30) 4 > 0.97 0.69 0.055 < 61 1

75 75 60 124 37 (50) 30 (40) 4 > 0.97 0.99 0.055 < 60 1

kW (hp) 15 (20) kW (hp) 11 (15) kHz 4 > 0.97 0.4 0.055 < 60 1

A A m

33 39 15 Screw terminals

40 46 15 M6 screw studs 10 50 M6 screw studs 10 50 M6 screw studs

47 53 15 M6 screw studs 10 50 M6 screw studs 10 50 M6 screw studs

63 72 15 M6 screw studs 10 50 M6 screw studs 10 50 M6 screw studs

78 88 15 M6 screw studs 10 50 M6 screw studs 10 50 M6 screw studs

mm2

2.5 10 Screw terminals

mm2

2.5 10 Screw terminals

DC link connection, connection for the braking resistor DCP/R1, DCN, R2 mm2 Conductor cross-section PE connection Motor cable length 4), max. Shielded m m Unshielded Degree of protection Dimensions Width Height - without integrated filter - with integrated filter Depth - without Control Unit - with Control Unit Frame size Weight, approx. without integrated filter with integrated filter
1) 2)

2.5 10 On housing with M5 screw 50 100 IP20

10 50 On housing with M6 screw 50 100 IP20 275 419 512 204 260 FSD 13 16
3)

10 50 On housing with M6 screw 50 100 IP20 275 419 512 204 260 FSD 13 16

10 50 On housing with M6 screw 50 100 IP20 275 419 512 204 260 FSD 13 16

10 50 On housing with M6 screw 100 100 IP20 275 499 635 204 260 FSE 16 23

mm mm mm mm mm

189 334 334 185 250 FSC

kg kg

7 7

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

The input current depends on the motor load and line impedance. The input currents apply for a load at rated power (based on Irated) for a line impedance corresponding to uK = 1 %. These current values without line reactor are stamped on the rating plate of the Power Module. Max. motor cable length 25 m (shielded) for PM240 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

Siemens D 11.1 2009

4/39

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Rated input current 3) with line reactor without line reactor Max. length of cable to braking resistor Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section kW m3/s dB A PM240 Power Modules 6SL32240BE33-7UA0 6SL32240BE33-7AA0 6SL32240BE34-5UA0 6SL32240BE34-5AA0 6SL32240BE35-5UA0 6SL32240BE35-5AA0 6SL32240BE37-5UA0 6SL32240BE37-5AA0 6SL32240BE38-8UA0 6SL32240BE41-1UA0

A A A A

90 90 75 150

110 110 90 180 55 (75) 45 (60) 4 > 0.97 1.42 0.15 < 60 1

145 145 110 220 75 (100) 55 (75) 4 > 0.97 1.93 0.15 < 60 1

178 178 145 290 90 (125) 75 (1oo) 4 > 0.97 2.31 0.15 < 65 1

205 205 178 308 110 (150) 90 (125) 2 > 0.97 2.43 0.15 < 65 1

250 250 205 375 132 (200) 110 (150) 2 > 0.97 2.53 0.15 < 65 1

kW (hp) 45 (60) kW (hp) 37 (50) kHz 4 > 0.97 1.21 2 0.055 < 62 1

A A m

94 105 15 M6 screw studs

115 129 15 M8 screw studs 25 120 M8 screw studs 25 120 M8 screw studs

151 168 15 M8 screw studs 25 120 M8 screw studs 25 120 M8 screw studs

186 204 15 M8 screw studs 25 120 M8 screw studs 25 120 M8 screw studs

210 245 15 M8 screw studs 25 120 M8 screw studs 25 120 M8 screw studs

250 299 15 M8 screw studs 25 120 M8 screw studs 25 120 M8 screw studs

mm2

10 50 M6 screw studs

mm2

10 50 M6 screw studs

DC link connection, connection for the braking resistor DCP/R1, DCN, R2 mm2 Conductor cross-section PE connection Motor cable length 4), max. Shielded m m Unshielded Degree of protection Dimensions Width Height - without integrated filter - with integrated filter Depth - without Control Unit - with Control Unit Frame size Weight, approx. without integrated filter with integrated filter
1) 2)

10 50

25 120

25 120

25 120

25 120

25 120

On housing with On housing with On housing with On housing with On housing with On housing with M6 screw M8 screw M8 screw M8 screw M8 screw M8 screw 100 100 IP20 mm mm mm mm mm 275 499 635 204 260 FSE kg kg 16 23 150 150 IP20 350 634 934 316 372 FSF 36 52 150 150 IP20 350 634 934 316 372 FSF 36 52
3)

150 150 IP20 350 634 934 316 372 FSF 36 52

150 150 IP20 350 634 316 372 FSF 39

150 150 IP20 350 634 316 372 FSF 39

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

The input current depends on the motor load and line impedance. The input currents apply for a load at rated power (based on Irated) for a line impedance corresponding to uK = 1 %. These current values without line reactor are stamped on the rating plate of the Power Module. Max. motor cable length 25 m (shielded) for PM240 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

4/40

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Rated input current 3) with line reactor without line reactor Max. length of cable to braking resistor Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section PE connection Motor cable length Shielded Unshielded Degree of protection Dimensions Width Height Depth Frame size Weight, approx. kg mm mm mm 326 1533 547 FSGX 174 326 1533 547 FSGX 174 326 1533 547 FSGX 174
4),

PM240 Power Modules 6SL3224-0XE41-3UA0 6SL3224-0XE41-6UA0 6SL3224-0XE42-0UA0

A A A A

302 302 250 400

370 370 302 483 200 (300) 160 (215) 2 > 0.98 4.4 0.36 < 69 1

477 477 370 592 250 (400) 200 (300) 2 > 0.98 5.5 0.36 < 69 1

kW (hp) 160 (250) kW (hp) 132 (200) kHz kW m3/s dB A 2 > 0.98 3.9 0.36 < 69 1

A A m

245 297 50 M10 screw stud

297 354 50 M10 screw stud 2 240 M10 screw stud 2 240 On housing with M10 screw 300 450 IP20

354 442 50 M10 screw stud 2 240 M10 screw stud 2 240 On housing with M10 screw 300 450 IP20

mm2

2 240 M10 screw stud

mm2

2 240 On housing with M10 screw

max. m m 300 450 IP20

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and line impedance. The input currents apply for a load at rated power (based on Irated) for a line impedance corresponding to uK = 1 %. These current values without line reactor are stamped on the rating plate of the Power Module. Max. motor cable length 25 m (shielded) for PM240 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

Siemens D 11.1 2009

4/41

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Characteristic curves
Derating data Pulse frequency
Rated power at 400 V 3 AC kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0 90.0 110.0 132.0 160.0 200.0 250.0 hp 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.0 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 Rated output current in A at a pulse frequency of 2 kHz 205.0 1) 250.0 1) 302.0 1) 370.0 1) 477.0
1)

4 kHz 1.3 1.7 2.2 3.1 4.1 5.9 7.7 10.2 18.0 25.0 32.0 38.0 45.0 62.0 75.0 90.0 110.0 145.0 178.0 178.0 202.0 250.0 302.0 370.0

6 kHz 1.1 1.4 1.9 2.6 3.5 5.0 6.5 8.7 16.2 22.1 27.2 32.3 38.3 52.7 63.8 76.5 93.5 123.3 151.3

8 kHz 0.9 1.2 1.5 2.2 2.9 4.1 5.4 7.1 13.3 18.2 22.4 26.6 31.5 43.4 52.5 63.0 77.0 101.5 124.6

10 kHz 0.8 1.0 1.3 1.9 2.5 3.5 4.6 6.1 11.4 15.6 19.2 22.8 27.0 37.2 45.0 54.0

12 kHz 0.7 0.9 1.1 1.6 2.1 3.0 3.9 5.1 9.5 13.0 16.0 19.0 22.5 31.0 37.5 45.0

14 kHz 0.6 0.8 1.0 1.4 1.8 2.7 3.5 4.6 8.6 11.7 14.4 17.1 20.3 27.9 33.8 40.5

16 kHz 0.5 0.7 0.9 1.2 1.6 2.4 3.1 4.1 7.6 10.4 12.8 15.2 18.0 24.8 30.0 36.0

1)

The pulse frequency can be switched over from 4 kHz (default) to 2 kHz only for the light overload (LO) duty cycle.

4/42

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Characteristic curves
Ambient temperature
100 % 75 74
G_D011_EN_00111

Installation altitude
100 % 90 80 70 60 0

Permissible output current

25

-10

10

20

30

40

50

C 60

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

High overload (HO) PM240 Power Modules frame sizes FSD to FSF
100 % 85 75
G_D011_EN_00213

G_D011_EN_00104

50

Permissible output current

Permissible output current

100 % Permissible input voltage 90 80 77 70 60 0

4
G_D011_EN_00105

50 25

-10

10

20

30

40

50

55

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

High overload (HO) PM240 Power Modules frame size FSGX


100 % 75 66
G_D011_EN_00110

Permissible output current

50 25

-10

10

20

30

40

50

C 60

Ambient temperature

Light overload (LO) PM240 Power Modules frame sizes FSD to FSF
100 % 85 75
G_D011_EN_00213

Permissible output current

50 25

-10

10

20

30

40

50

55

Ambient temperature

Light overload (LO) PM240 Power Modules frame size FSGX

Note: The operating temperature ranges of the Control Units should be taken into account. The temperature ranges are specified in the technical specifications under Control Units.

Siemens D 11.1 2009

4/43

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Dimensional drawings
145 (5.71) 73 (2.87) 4.5 (0.18)
173 (6.81)
G_D011_EN_00091

Drill pattern

PM240 Power Module frame size FSA

Mounted with 2 M4 studs, 2 M4 nuts, 2 M4 washers.

Ventilation clearance required at top and bottom: 100 mm (3.94 inches). Ventilation clearance required at sides: Ambient temperature 40 C: 0 mm (0 inches). Ambient temperature > 40 C: 30 mm (1.18 inches).

When the Control Unit is plugged on, the mounting depth increases by 65 mm (2.56 inches) and the total height by 14 mm (0.55 inches). Exception: for CU240E, mounting depth +31 mm (+1.22 inches), total height +32 mm (+1.26 inches). All dimensions in mm (values in brackets are in inches).

165 (6.5)

153 (6.02)

133 (5.24) 4.8 (0.19)

270 (10.63)

160 (6.3)

Drill pattern

G_D011_EN_00092

PM240 Power Module frame size FSB

Mounted with 4 M4 studs, 4 M4 nuts, 4 M4 washers. Ventilation clearance required at top and bottom: 100 mm (3.94 inches). Ventilation clearance required at sides: Ambient temperature 40 C: 0 mm (0 inches). Ambient temperature > 40 C: 40 mm (1.57 inches).

When the Control Unit is plugged on, the mounting depth increases by 65 mm (2.56 inches). Exception: for CU240E, mounting depth +31 mm (+1.22 inches). All dimensions in mm (values in brackets are in inches).

4/44

Siemens D 11.1 2009

258 (10.16)

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Dimensional drawings
185 (7.28) 189 (7.44) 167 (6.57) 5.5 (0.22)

334 (13.15)

Drill pattern

323 (12.72)

G_D011_EN_0093

PM240 Power Module frame size FSC

Mounted with 4 M5 studs, 4 M5 nuts, 4 M5 washers. Ventilation clearance required at top and bottom: 100 mm (3.94 inches). Ventilation clearance required at sides: Ambient temperature 40 C: 0 mm (0 inches). Ambient temperature > 40 C: 50 mm (1.97 inches).

When the Control Unit is plugged on, the mounting depth increases by 65 mm (2.56 inches). Exception: for CU240E, mounting depth +31 mm (+1.22 inches). All dimensions in mm (values in brackets are in inches).

Siemens D 11.1 2009

4/45

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Dimensional drawings

204 (8.03)

275 (10.83)

235 (9.25)

8.5 (0.33)

361 (14.21)

419 (16.5)

Drill pattern

4
G_D011_EN_00094

PM240 Power Module frame size FSD without line filter


11 (0.43) 419 (16.5)

204 (8.03)

275 (10.83)

235 (9.25) 8.5 (0.33)

455 (17.91)

512 (20.16)

Drill pattern

G_D011_EN_00095

PM240 Power Module frame size FSD with integrated class A line filter

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 300 mm (11.81 inches). Ventilation clearance required at front: 28 mm (1.1 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

4/46

Siemens D 11.1 2009

325 (12.8)

11 (0.43)

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Dimensional drawings
204 (8.03) 275 (10.83) 235 (9.25) 8.5 (0.33)
11 (0.43) 405 (15.94)

441 (17.36)

499 (19.65)

Drill pattern

4
G_D011_EN_00096

PM240 Power Module frame size FSE without line filter

204 (8.03)

275 (10.83)

235 (9.25) 8.5 (0.33)

577 (22.72)

635 (25)

Drill pattern

G_D011_EN_00097

PM240 Power Module frame size FSE with integrated class A line filter

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 300 mm (11.81 inches). Ventilation clearance required at front: 28 mm (1.1 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

541 (21.3)

11 (0.43)

Siemens D 11.1 2009

4/47

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Dimensional drawings
316 (12.44) 350 (13.78) 300 (11.81) 8.5 (0.33) 11 (0.43) 598 (23.54)
899 (35.39) 11 (0.43)

634 (24.96)

Drill pattern

G_D011_EN_00098

PM240 Power Module frame size FSF without line filter


316 (12.44) 350 (13.78) 300 (11.81)

8.5 (0.33)

934 (36.77)

Drill pattern

G_D011_EN_00099

PM240 Power Module frame size FSF with integrated class A line filter

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 350 mm (13.78 inches). Ventilation clearance required at front: 28 mm (1.1 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

4/48

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM240 Power Modules 0.37 kW to 250 kW (0.5 hp to 400 hp)

Dimensional drawings
14.5 (0.571) 547 (21.6) 326 (12.9) 37 (1.46) 125 (4.92) 125 (4.92)

9 (0.35)

1533 (60.35)

Drill pattern

G_D011_EN_00205

PM240 Power Module frame size FSGX without line filter

Mounted with 6 M8 studs, 6 M8 nuts, 6 M8 washers. Ventilation clearance required at the top: 250 mm (9.84 inches). Ventilation clearance required at the bottom: 150 mm (5.91 inches). Ventilation clearance required at front: 50 mm (1.97 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth does not increase.

All dimensions in mm (values in brackets are in inches).

Siemens D 11.1 2009

1506 (59.29)

4/49

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Overview

Example: PM250 Power Modules frame sizes FSC to FSF

The PM250 Power Module features an absolutely unique technology Efficient Infeed Technology. This feature provides the ability to feed energy back into the supply system in the generator mode (electronic braking) so that the energy is not wasted in a braking resistor. This saves space in the control cabinet. The time-consuming process of dimensioning the braking resistor and the expense of the extra wiring are eliminated. Furthermore, heat losses in the control cabinet are reduced. The innovative circuit design used in Efficient Infeed Technology reduces the line harmonics. There is no need to use an optional line reactor at the supply infeed. This saves space and costs for engineering and procurement. The PM250 Power Module is also suitable for use in safety-oriented applications. In conjunction with a Fail-safe Control Unit, the drive can be turned into a Safety Integrated Drive (see Control Units). The permissible cable lengths between inverter and motor are limited. Longer cables can be used if output reactors are connected (see load-side power components). Frame sizes FSD to FSF of the PM250 Power Modules are available both with as well as without integrated class A line filter. For frame size FSC of PM250 Power Module with an integrated class A line filter, an additional class B base filter is available for achieving class B (see line-side power components). The PM250 Power Modules with integrated class A line filter are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded (TN, TT) and non-grounded (IT) supply systems.

Overview of how customers benefit from Efficient Infeed Technology For more detailed information, please refer to the part Highlights, in section Efficient Infeed Technology.
Standard Technology Line reactor Required Efficient Infeed Technology Not required

Braking resistor

Required

Not required

Configuration overhead

Standard

Low

Generated harmonics

Standard

Minimal

Heat generated when braking

Yes

No

Power infeed

Standard

Approx. 22% less

Power consumption

Standard

Approx. 22% less

Energy efficiency

Standard

Good

Reactive power compensation

No

Yes

Installation outlay

Standard

Low

G_D011_EN_00182

4/50

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Selection and ordering data


To ensure that a suitable Power Module is selected, the following currents should be used for applications: rated output current for applications with light overload (LO) base load current for applications with high overload (HO)
Rated power 1) Rated output current2) Irated A 18 25 32 38 45 60 75 90 110 145 178 Power based on the base load current 3) kW 5.5 7.5 11.0 15.0 18.5 22 30 37 45 55 75 hp 7.5 10 15 20 25 30 40 50 60 75 100 Base load current 3) IH A 13.2 19 26 32 38 45 60 75 90 110 145 FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF
new new new new new new new new

With reference to the rated output current, the modules support at least 2-pole to 6-pole low-voltage motors, e.g. the new 1LE1 motor series (please refer to the Appendix for further information). The rated power is merely a guide value. For a description of the overload performance, please refer to the general technical specifications of the Power Modules.
SINAMICS G120 PM250 Power Module without integrated line filter Order No. 6SL3225-0BE31-5UA0 6SL3225-0BE31-8UA0 6SL3225-0BE32-2UA0 6SL3225-0BE33-0UA0 6SL3225-0BE33-7UA0 6SL3225-0BE34-5UA0 6SL3225-0BE35-5UA0 6SL3225-0BE37-5UA0 SINAMICS G120 PM250 Power Module with integrated class A line filter Order No. 6SL3225-0BE25-5AA0 6SL3225-0BE27-5AA0 6SL3225-0BE31-1AA0 6SL3225-0BE31-5AA0 6SL3225-0BE31-8AA0 6SL3225-0BE32-2AA0 6SL3225-0BE33-0AA0 6SL3225-0BE33-7AA0 6SL3225-0BE34-5AA0 6SL3225-0BE35-5AA0 6SL3225-0BE37-5AA0

Frame size

kW 7.5 11.0 15.0 18.5 22 30 37 45 55 75 90

hp 10 15 20 25 30 40 50 60 75 100 125

380 480 V 3 AC

1) 2)

Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for light overload (LO). The rated output current Irated is based on the duty cycle for light overload (LO). These current values are valid for 400 V and are stamped on the rating plate of the Power Module.

3)

The base load current IH is based on the duty cycle for high overload (HO).

Siemens D 11.1 2009

4/51

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Integration
PM250 Power Modules communicate with the Control Unit via the PM-IF interface. PM250 Power Modules feature the following interfaces as standard: PM-IF interface to connect the PM250 Power Module to the Control Unit. The PM250 Power Module also supplies power to the Control Unit using an integrated power supply
ext. 24 V DC or via Power Module required 24 V 0V

Motor connected using screw terminals or screw studs Control for the Brake Relay or the Safe Brake Relay for controlling a motor brake 2 PE/protective conductor connections

380 V to 480 V 3 AC L1 L2 L3 PE

4
PE U1/ L1 V1/ W1/ L2 L3

Power Module PM250

Line filter class A


3 ~

Control Unit

PM-IF Interface

= 3 ~

PE U2

V2

W2

Brake Relay M 3 ~

Motor brake

PM250 Power Module connection diagram with or without integrated class A line filter

4/52

Siemens D 11.1 2009

G_D011_EN_00115a

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Integration
Power and DC link components which are optionally available depending on the Power Module used The following line-side power components, DC link components and load-side power components are optionally available in the appropriate frames sizes for the Power Modules:
Frame size FSA Available frame sizes Line filter, class A Line filter, class B Line reactor
1)

FSB

FSC

FSD

FSE

FSF

FSGX

PM250 Power Module with line-commutated energy recovery



2)

Line-side power components I U U U


1)

F S S
1)

F S S
1)

F S S
1)

DC link components Braking resistor Output reactor Sine-wave filter U S I F = = = = =


2) 2) 2) 2)

Load-side power components

Base component Lateral mounting Integrated Not possible Power Modules available with and without integrated class A filter

Available as base components Many system components for PM250 Power Modules are designed as base components, that is, the component is mounted on the baseplate and the PM250 Power Module above it in a space-saving design. Up to two base components can be mounted above one another. The following diagram shows the basic layout of a PM250 Power Module with additional class B line filter as base component: The following example shows the structure for two base components:

Power supply Power module Line filter

Output reactor

Power supply Power module Line filter

G_D211_EN_00107a

to the motor

Basic layout of a PM250 Power Module with class B line filter as base component and output reactor

Basic layout of a PM250 Power Module with class B line filter as base component

1) 2)

A line reactor is not required and must not be used in conjunction with a PM250 or PM260 Power Module. Line-commutated energy recovery is possible in conjunction with a PM250 or PM260 Power Module. A braking resistor cannot be connected and is not necessary.

G_D211_EN_00108a

Siemens D 11.1 2009

4/53

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Integration
Maximum permissible cable lengths from the motor to the inverter when using output reactors or sine-wave filters depending on the voltage range The following load-side power components in the appropriate frame sizes are optionally available for the Power Modules and result in the following maximum cable lengths:
Maximum permissible motor cable lengths (shielded/unshielded) in m Frame sizes FSA Available frame sizes With optional output reactor at 380 V (10 %) to 400 V 3 AC at 401 V to 480 V (+10 %) 3 AC With optional sine-wave filter at 380 V (10 %) to 400 V 3 AC at 401 V to 480 V (+10 %) 3 AC 200/300 200/300 200/300 200/300 200/300 200/300 200/300 200/300 150/225 100/150 200/300 200/300 200/300 200/300 200/300 200/300 FSB FSC 50/100 FSD 50/100 FSE 50/100 FSF 50/100 FSGX

PM250 Power Module with line-commutated energy recovery


Without output reactor/sine-wave filter

Derating data The following inverter output currents can still be implemented for long motor cables without output reactor and sine-wave filter. Derating for PM250 Power Modules, frame sizes FSC to FSF for shielded motor cables. From frame size FSD and higher, only the particular main Power Module types were tested. The values also apply to the other Power Modules of the particular frame size.

Rated power (at IH) kW 5.5 7.5 11.0 22.0 37.0 75.0 hp 7.5 10 15 30 50 100

Frame size

Base load current IH A

Rated output current Irated A 18 25 32 60 90 178

Motor conCurrent derating nection cross- of the output current as a % of the base load current section for the cable lengths (MOTION-CONNECT) mm2 10 10 10 35 35 95 50 m 100 % 100 % 100 % 100 % 100 % 100 % 100 m 70 % 90 % 90 % 95 % 100 % 100 % 150 m 45 % 80 % 80 % 90 % 95 % 100 % 200 m 85 % 90 % 95 %

FSC FSC FSC FSD FSE FSF

13.2 19 26 45 75 145

Not possible

4/54

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Technical specifications
General technical specifications
PM250 Power Modules System operating voltage Line supply requirements Line short circuit voltage uK Input frequency Output frequency Control type V/f Control type Vector Pulse frequency Power factor Inverter efficiency Modulation depth Overload capability High overload (HO) Light overload (LO) Electromagnetic compatibility Possible braking methods Degree of protection Operating temperature High overload (HO) Light overload (LO) Storage temperature Relative humidity Cooling Installation altitude Standard SCCR (Short Circuit Current Rating) 1) Protection functions 0 50 C (32 122 F) without derating, > 50 60 C see derating characteristics 0 40 C (32 104 F) without derating, > 40 60 C see derating characteristics 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible Internal air cooling, power units with increased air cooling using integrated fans up to 1000 m above sea level without power reduction, > 1000 m see derating characteristics FSC: 10 kA FSD, FSE, FSF: 42 kA Undervoltage Overvoltage Overcontrol/overload Ground fault Short circuit Stall protection Motor blocking protection Motor overtemperature Inverter overtemperature Parameter locking UL, cUL, CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC 1.5 rated output current (i.e. 150 % overload ) for 57 s with a cycle time of 300 s 2 rated output current (i.e. 200 % overload) for 3 s with a cycle time of 300 s 1.1 rated output current (i.e. 110 % overload ) for 57 s with a cycle time of 300 s 1.5 rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s Optional class A or B line filter acc. to EN 55011 is available Energy recovery in the generator mode IP20 0 650 Hz 0 200 Hz 4 kHz (standard), higher pulse frequencies up to 16 kHz, see the derating data 0.9 95 97 % 87 % 380 480 V 3 AC 10 % 1% 47 63 Hz

Standards conformance CE mark

1)

Applies to industrial control cabinet installations to NEC Article 409/UL 508A. For further information, visit us on the Internet at: http://support.automation.siemens.com/WW/view/en/23995621

Siemens D 11.1 2009

4/55

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC With integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH kW (hp) 7.5 (10) kW (hp) 5.5 (7.5) kHz kW m3/s dB A 4 0.95 0.26 0.038 Available soon 1 11 (15) 7.5 (10) 4 0.95 0.28 0.038 Available soon 1 15 (20) 11 (15) 4 0.95 0.31 0.038 Available soon 1 A A A A 18 18 13.2 26.4 25 25 19 38 32 32 26 52 PM250 Power Modules 6SL3225-0BE25-5AA0 6SL3225-0BE27-5AA0 6SL3225-0BE31-1AA0

Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Input current 3) Rated current Current based on IH Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section PE connection Motor cable length, max. 4) Shielded Unshielded Degree of protection Dimensions Width Height Depth - without Control Unit - with Control Unit Frame size Weight, approx.

A A

18 13.2 Screw terminals

25 19 Screw terminals 2.5 10 Screw terminals 2.5 10 On housing with M5 screw 50 100 IP20 189 334 185 250 FSC 7.5

32 26 Screw terminals 2.5 10 Screw terminals 2.5 10 On housing with M5 screw 50 100 IP20 189 334 185 250 FSC 7.5

mm2

2.5 10 Screw terminals

mm2

2.5 10 On housing with M5 screw

m m

50 100 IP20

mm mm mm mm kg

189 334 185 250 FSC 7.5

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and is valid for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at the rated power (based on Irated) these current values are specified on the rating plate.

4/56

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Input current 3) Rated current based on IH Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section PE connection Motor cable length, max. Shielded Unshielded Degree of protection Dimensions Width Height - without integrated line filter mm - With integrated line filter Depth - without Control Unit - with Control Unit Frame size Weight, approx. Without integrated line filter kg With integrated line filter kg 13 15 13 15 13 16 mm mm 204 260 FSD 204 260 FSD 204 260 FSD mm 419 512 419 512 419 512 mm 275 275 275
4)

PM250 Power Modules 6SL3225-0BE31-5UA0 6SL3225-0BE31-5AA0 6SL3225-0BE31-8UA0 6SL3225-0BE31-8AA0 6SL3225-0BE32-2UA0 6SL3225-0BE32-2AA0

A A A A

38 38 32 64

45 45 38 76 22 (30) 18.5 (25) 4 > 0.97 0.52 0.022 < 60 1

60 60 45 90 30 (40) 22 (30) 4 > 0.97 0.68 0.039 < 61 1

kW (hp) 18.5 (25) kW (hp) 15 (20) kHz kW m3/s dB A 4 > 0.97 0.42 0.022 < 60 1

A A

36 30 M6 screw studs

42 36 M6 screw studs 10 35 M6 screw studs 10 35 On housing with M6 screw 50 100 IP20

56 42 M6 screw studs 10 35 M6 screw studs 10 35 On housing with M6 screw 50 100 IP20

mm2

10 35 M6 screw studs

mm2

10 35 On housing with M6 screw

m m

50 100 IP20

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and is valid for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at the rated power (based on Irated) these current values are specified on the rating plate. Max motor cable length 25 m (shielded) for PM250 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

Siemens D 11.1 2009

4/57

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Technical specifications
Line supply voltage 380 480 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 400 V 3 AC Rated current Irated1) Base load current IL1) Base load current IH2) Imax Rated power A A A A 75 75 60 120 90 90 75 150 45 (60) 37 (50) 4 > 0.97 1.21 0.039 < 62 1 110 110 90 180 55 (75) 45 (60) 4 > 0.97 1.42 0.094 < 60 1 145 145 110 220 75 (100) 55 (75) 4 > 0.97 1.93 0.094 < 60 1 178 178 145 290 90 (125) 75 (100) 4 > 0.97 2.31 0.117 < 65 1 PM250 Power Modules 6SL32250BE33-0UA0 6SL32250BE33-0AA0 6SL32250BE33-7UA0 6SL32250BE33-7AA0 6SL32250BE34-5UA0 6SL32250BE34-5AA0 6SL32250BE35-5UA0 6SL32250BE35-5AA0 6SL32250BE37-5UA0 6SL32250BE37-5AA0

based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Input current 3) Rated current based on IH Line supply connection U1/L1, V1/L2, W1/L3 Max. conductor cross-sect. Motor connection U2, V2, W2

kW (hp) 37 (50) kW (hp) 30 (40) kHz kW m3/s dB A 4 > 0.97 0.99 0.022 < 60 1

A A

70 56 M6 screw studs

84 70 M6 screw studs 10 50 M6 screw studs 10 50 On housing with M6 screw 50 100 IP20 275 499 635 204 260 FSE 14 21
3)

102 84 M8 screw studs 25 120 M8 screw studs 25 120 On housing with M8 screw 50 100 IP20 350 634 934 316 372 FSF 35 51

135 102 M8 screw studs 25 120 M8 screw studs 25 120 On housing with M8 screw 50 100 IP20 350 634 934 316 372 FSF 35 51

166 135 M8 screw studs 25 120 M8 screw studs 25 120 On housing with M8 screw 50 100 IP20 350 634 934 316 372 FSF 35 51

mm2

10 50 M6 screw studs 10 50 On housing with M6 screw

Max. conductor cross-sect. mm2 PE connection Motor cable length, max. 4) Shielded Unshielded Degree of protection Dimensions Width Height - without integrated line filter mm - With integrated line filter Depth - without Control Unit - with Control Unit Frame size Weight, approx. Without integrated line filter kg With integrated line filter
1) 2)

m m

50 100 IP20

mm

275 499 635 204 260 FSE 14 21

mm mm mm

kg

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

The input current depends on the motor load and is valid for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at the rated power (based on Irated) these current values are specified on the rating plate. Max motor cable length 25 m (shielded) for PM250 Power Modules with integrated line filter to maintain the limit values of EN 61800-3 Category C2.

4)

4/58

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Characteristic curves
Derating data Pulse frequency
Rated power at 400 V 3 AC kW 7.5 11.0 15.0 18.5 22.0 30.0 37.0 45.0 55.0 75.0 90.0 hp 10 15 20 25 30 40 50 60 75 100 125 Rated output current in A at a pulse frequency of 4 kHz 18 25 32 38 45 60 75 90 110 145 178 6 kHz 12.5 18.1 24.7 32 38 51 64 77 94 123 151 8 kHz 11.9 17.1 23.4 27 32 42 53 63 77 102 125 10 kHz 10.6 15.2 20.8 23 27 36 45 54 12 kHz 9.2 13.3 18.2 19 23 30 38 45 14 kHz 7.9 11.4 15.6 17 20 27 34 41 16 kHz 6.6 9.5 13 15 18 24 30 36

Ambient temperature
100 % 75 74
G_D011_EN_00111

Installation altitude
100 % 90 80 70 60 0

Permissible output current

25

-10

10

20

30

40

50

C 60

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

High overload (HO)


100 % 75 66
G_D011_EN_00110

Permissible output current

100 % Permissible input voltage 90 80 77 70 60 0

25

-10

10

20

30

40

50

C 60

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

Light overload (LO)

Note: The operating temperature ranges of the Control Units should be taken into account. The temperature ranges are specified in the technical specifications under Control Units.

Siemens D 11.1 2009

4/59

G_D011_EN_00105

50

G_D011_EN_00104

50

Permissible output current

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Dimensional drawings
185 (7.28) 189 (7.44) 167 (6.57) 5.5 (0.22)

334 (13.15)

Drill pattern

4
PM250 Power Module frame size FSC with integrated class A line filter

G_D011_EN_0093

Mounted with 4 M5 studs, 4 M5 nuts, 4 M5 washers. Ventilation clearance required at top and bottom: 125 mm (4.92 inches). Ventilation clearance required at sides: Ambient temperature 40 C: 0 mm (0 inches). Ambient temperature > 40 C: 50 mm (1.97 inches).

When the Control Unit is plugged on, the mounting depth increases by 65 mm (2.56 inches). Exception: for CU240E, mounting depth +31 mm (+1.22 inches). All dimensions in mm (values in brackets are in inches).

4/60

Siemens D 11.1 2009

323 (12.72)

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Dimensional drawings

204 (8.03)

275 (10.83)

235 (9.25)

8.5 (0.33)

361 (14.21)

419 (16.5)

Drill pattern

325 (12.8)

11 (0.43)

4
G_D011_EN_00094

PM250 Power Module frame size FSD without line filter


11 (0.43) 419 (16.5)

204 (8.03)

275 (10.83)

235 (9.25) 8.5 (0.33)

455 (17.91)

512 (20.16)

Drill pattern

G_D011_EN_00095

PM250 Power Module frame size FSD with integrated class A line filter

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 300 mm (11.81 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

Siemens D 11.1 2009

4/61

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Dimensional drawings
204 (8.03) 275 (10.83) 235 (9.25) 8.5 (0.33)
11 (0.43) 405 (15.94)

441 (17.36)

499 (19.65)

Drill pattern

4
G_D011_EN_00096

PM250 Power Module frame size FSE without line filter

204 (8.03)

275 (10.83)

235 (9.25) 8.5 (0.33)

577 (22.72)

635 (25)

Drill pattern

G_D011_EN_00097

PM250 Power Module frame size FSE with integrated class A line filter

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 300 mm (11.81 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

4/62

Siemens D 11.1 2009

541 (21.3)

11 (0.43)

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM250 Power Modules 7.5 kW to 75 kW (10 hp to 100 hp)

Dimensional drawings
316 (12.44) 350 (13.78) 300 (11.81) 8.5 (0.33) 11 (0.43) 598 (23.54)

634 (24.96)

Drill pattern

G_D011_EN_00098

PM250 Power Module frame size FSF without line filter


316 (12.44) 350 (13.78) 300 (11.81)
11 (0.43) 899 (35.39)

8.5 (0.33)

934 (36.77)

Drill pattern

G_D011_EN_00099

PM250 Power Module frame size FSF with integrated class A line filter

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 350 mm (13.78 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

Siemens D 11.1 2009

4/63

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Overview
Overview of how customers benefit from Efficient Infeed Technology For more detailed information, please refer to the part Highlights, in section Efficient Infeed Technology.
Standard Technology Line reactor Required Efficient Infeed Technology Not required

Braking resistor

Required

Not required

Configuration overhead

Standard

Low

Generated harmonics

Standard

Minimal

Example: PM260 FSD Power Module

The PM260 Power Module features an absolutely unique technology Efficient Infeed Technology. This feature provides the ability to feed energy back into the supply system in the generator mode (electronic braking) so that the energy is not wasted in a braking resistor. This saves space in the control cabinet. The time-consuming process of dimensioning the braking resistor and the expense of the extra wiring are eliminated. Furthermore, heat losses in the control cabinet are reduced. The innovative circuit design used in Efficient Infeed Technology reduces the line harmonics. There is no need to use an optional line reactor at the supply infeed. This saves space and costs for engineering and procurement. The PM260 Power Modules are also characterized by a higher rated pulse frequency combined with a high efficiency and an integrated sine-wave filter. The integrated sine-wave filter ensures that the inverter output current is sinusoidal and supports cable lengths of up to 200 m shielded and 300 m unshielded. An output reactor is therefore not required. Furthermore, lower bearing currents and voltage stress are generated that reduces the overall stress on the motor. The use of SiC free-wheeling diodes an absolutely unique innovation makes the PM260 Power Module extremely compact. It is also highly resistant to thermal loading and operates very quietly as a result of the high clock frequencies.

Heat generated when braking

Yes

No

Power infeed

Standard

Approx. 22% less

Power consumption

Standard

Approx. 22% less

Energy efficiency

Standard

Good

Reactive power compensation

No

Yes

Installation outlay

Standard

Low

G_D011_EN_00182

Standard motors can be used in conjunction with the PM260 Power Module. The winding system insulation strength does not have to be increased. The PM260 Power Module is suitable for safety-oriented applications. In conjunction with a Fail-safe Control Unit, the drive can be turned into a Safety Integrated Drive (see Control Units). The PM260 Power Modules with integrated class A line filter are suitable for connection to TN supply systems. Power Modules without integrated line filter can be connected to grounded (TN, TT) and non-grounded (IT) supply systems.

Overview of how customers benefit from SiC free-wheeling diodes 7 Low switching losses at high fundamental frequency 7 High speeds possible 7 Quiet operation thanks to pulse frequency = 16 kHz 7 High thermal load capacity (small heatsinks) 7 Very compact units 7 Increased ruggedness 7 High efficiency 7 Low forward losses 7 Power unit with regenerative feedback capability 7 Integrated sine-wave filter, long unshielded cables can be used 7 Can be used with motors without a special insulation 7 Very low bearing currents, no bearing insulation required

4/64

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Selection and ordering data


To ensure that a suitable Power Module is selected, the following currents should be used for applications: rated output current for applications with light overload (LO) base load current for applications with high overload (HO)
Rated power 1) Rated output current 2) Irated A 14 19 23 35 42 62 Power based on the base load current 3) kW 7.5 11 15 22 30 37 hp 10 15 20 30 40 50 Base load current 3) IH A 10 14 19 26 35 42 FSD FSD FSD FSF FSF FSF
new new new new new new

With reference to the rated output current, the modules support at least 2-pole to 6-pole low-voltage motors, e.g. the new 1LE1 motor series (please refer to the Appendix for further information). The rated power is merely a guide value. For a description of the overload performance, please refer to the general technical specifications of the Power Modules.
SINAMICS G120 PM260 Power Module without integrated line filter Order No. 6SL3225-0BH27-5UA1 6SL3225-0BH31-1UA1 6SL3225-0BH31-5UA1 6SL3225-0BH32-2UA1 6SL3225-0BH33-0UA1 6SL3225-0BH33-7UA1
new new new new new new

Frame size

SINAMICS G120 PM260 Power Module with integrated class A line filter Order No. 6SL3225-0BH27-5AA1 6SL3225-0BH31-1AA1 6SL3225-0BH31-5AA1 6SL3225-0BH32-2AA1 6SL3225-0BH33-0AA1 6SL3225-0BH33-7AA1

kW 11.0 15.0 18.5 30 37 55

hp 15 20 25 40 50 75

500 690 V 3 AC

1) 2)

Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for light overload (LO). The rated output current Irated is based on the duty cycle for light overload (LO). These current values are valid for 690 V and are stamped on the rating plate of the Power Module.

3)

The base load current IH is based on the duty cycle for high overload (HO).

Siemens D 11.1 2009

4/65

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Integration
PM260 Power Modules communicate with the Control Unit via the PM-IF interface. PM260 Power Modules feature the following interfaces as standard: PM-IF interface to connect the PM260 Power Module to the Control Unit. The PM260 Power Module also supplies power to the Control Unit using the integrated power supply
ext. 24 V DC or via Power Module required 24 V 0V

Motor connected using screw terminals or screw studs Control for the Brake Relay or the Safe Brake Relay for controlling a motor brake 2 PE/protective conductor connections

500 V to 690 V 3 AC L1 L2 L3 PE

4
PE U1/ L1 V1/ W1/ L2 L3 Line filter class A 3~

Power Module PM260

Control Unit

PM-IF Interface

= 3~
G_D011_EN_00116b

Sine-wave filter A B PE U2 V2 W2

Brake Relay M 3 ~ Motor brake

PM260 Power Module connection diagram with or without integrated class A line filter

4/66

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Integration
Power and DC link components which are optionally available depending on the Power Module used The following line-side power components, DC link components and load-side power components are optionally available in the appropriate frame sizes for the Power Modules:
Frame size FSA Available frame sizes Line-side power components Line filter, class A Line filter, class B Line reactor
1)

FSB

FSC

FSD

FSE

FSF

FSGX

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter

2)

F I
1)

F I
1)

DC link components Braking resistor Output reactor Sine-wave filter


2) 2)

Load-side power components

I = Integrated = Not possible F = Power Modules available with and without integrated class A filter

Maximum permissible cable lengths from the motor to the inverter when using output reactors or sine-wave filters depending on the voltage range The following load-side power components in the appropriate frame sizes are optionally available for the Power Modules and result in the following maximum cable lengths:
Maximum permissible motor cable lengths (shielded/unshielded) in m Frame sizes FSA Available frame sizes With integrated sine-wave filter at 500 V to 690 V 3 AC (10 %) 200/300 200/300 FSB FSC FSD FSE FSF FSGX

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter

1)

A line reactor is not required and must not be used in conjunction with a PM250 or PM260 Power Module.

2)

Line-commutated energy recovery is possible in conjunction with a PM250 or PM260 Power Module. A braking resistor cannot be connected and is not necessary.

Siemens D 11.1 2009

4/67

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Technical specifications
General technical specifications
PM260 Power Modules System operating voltage Line supply requirements Line short circuit voltage uK Input frequency Output frequency Control type V/f Control type Vector Pulse frequency Power factor 0 200 Hz 0 200 Hz 16 kHz (standard) 0.95 95 97 % 87 % 1.5 rated output current (i.e. 150 % overload ) for 57 s with a cycle time of 300 s 2 rated output current (i.e. 200 % overload) for 3 s with a cycle time of 300 s 1.1 rated output current (i.e. 110 % overload ) for 57 s with a cycle time of 300 s 1.4 rated output current (i.e. 140 % overload) for 3 s with a cycle time of 300 s Optional class A line filter according to EN 55011 is available Energy recovery in the generator mode IP20 0 50 C (32 122 F) without derating, > 50 60 C see derating characteristics 0 40 C (32 104 F) without derating, > 40 60 C see derating characteristics 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible Internal air cooling, power units with increased air cooling using integrated fans up to 1000 m above sea level without power reduction, > 1000 m see derating characteristics 500 690 V 3 AC 10 % For operation from 500 V 10 % linearly reduced see derating characteristics 1% 47 63 Hz

Inverter efficiency Modulation depth Overload capability High overload (HO) Light overload (LO) Electromagnetic compatibility Possible braking methods Degree of protection Operating temperature High overload (HO) Light overload (LO) Storage temperature Relative humidity Cooling Installation altitude

Standard SCCR (Short Circuit Cur- 42 kA rent Rating) 1) Protection functions Undervoltage Overvoltage Overcontrol/overload Ground fault Short circuit Stall protection Motor blocking protection Motor overtemperature Inverter overtemperature Parameter locking CE According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC

Standards conformance CE mark

1)

Applies to industrial control cabinet installations to NEC Article 409/UL 508A. For further information, visit us on the Internet at: http://support.automation.siemens.com/WW/view/en/23995621

4/68

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Technical specifications
Line supply voltage 500 690 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 690 V 3 AC Rated current Irated 1) Base load current IL 1) Base load current IH 2) Imax Rated power based on IL based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Input current 3) Rated current based on IH Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section PE connection Motor cable length, max. Shielded Unshielded Degree of protection Dimensions Width Height Depth - without Control Unit - with Control Unit Frame size Weight, approx. without integrated filter with integrated filter kg kg 22 23 22 23 22 23 mm mm 204 260 FSD 204 260 FSD 204 260 FSD mm mm 275 512 275 512 275 512
4)

PM260 Power Modules 6SL3225-0BH27-5UA1 6SL3225-0BH27-5AA1 6SL3225-0BH31-1UA1 6SL3225-0BH31-1AA1 6SL3225-0BH31-5UA1 6SL3225-0BH31-5AA1

A A A A

14 14 10 20

19 19 14 28 15 (20) 11 (15) 16 0.95 0.72 0.044 < 64 1

23 23 19 38 18.5 (25) 15 (20) 16 0.95 0.82 0.044 < 64 1

kW (hp) 11 (15) kW (hp) 7.5 (10) kHz kW m3/s dB A 16 0.95 0.58 0.044 < 64 1

A A

13 10 Terminal strip

18 13 Terminal strip 2.5 16 Terminal block 2.5 16 On housing with M6 screw 200 300 IP20

22 18 Terminal strip 2.5 16 Terminal block 2.5 16 On housing with M6 screw 200 300 IP20

mm2

2.5 16 Terminal block

mm2

2.5 16 On housing with M6 screw

m m

200 300 IP20

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and is valid for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at the rated power (based on Irated) these current values are specified on the rating plate. Shielded motor cables must be used in order to maintain the limit values for field-conducted disturbances according to EN 61800-3 Class C2.

4)

Siemens D 11.1 2009

4/69

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Technical specifications
Line supply voltage 500 690 V 3 AC Without integrated line filter With integrated line filter Output current at 50 Hz 690 V 3 AC Rated current Irated 1) Base load current IL 1) Base load current IH 2) Imax Rated power based on IL kW (hp) 30 (40) kW (hp) 22 (30) kHz kW m3/s dB A 16 0.95 1.13 0.131 < 70 1 37 (50) 30 (40) 16 0.95 1.29 0.131 < 70 1 55 (75) 37 (50) 16 0.95 1.73 0.131 < 70 1 based on IH Rated pulse frequency Efficiency Power loss (at rated current) Cooling air requirement Sound pressure level LpA (1 m) 24 V DC power supply for Control Unit Input current 3) Rated current based on IH Line supply connection U1/L1, V1/L2, W1/L3 Conductor cross-section Motor connection U2, V2, W2 Conductor cross-section PE connection Motor cable length, max. Shielded Unshielded Degree of protection Dimensions Width Height Depth - without Control Unit - with Control Unit Frame size Weight, approx. without integrated filter with integrated filter kg kg 56 58 56 58 56 58 mm mm 316 372 FSF 316 372 FSF 316 372 FSF mm mm 350 634 350 634 350 634
4)

PM260 Power Modules 6SL3225-0BH32-2UA1 6SL3225-0BH32-2AA1 6SL3225-0BH33-0UA1 6SL3225-0BH33-0AA1 6SL3225-0BH33-7UA1 6SL3225-0BH33-7AA1

A A A A

35 35 26 52

42 42 35 70

62 62 42 84

A A

34 26 M6 screw studs

41 34 M6 screw studs 10 50 M6 screw studs 10 50 On housing with M6 screw 200 300 IP20

60 41 M6 screw studs 10 50 M6 screw studs 10 50 On housing with M6 screw 200 300 IP20

mm2

10 50 M6 screw studs

mm2

10 50 On housing with M6 screw

m m

200 300 IP20

1) 2)

The rated output current Irated and the base load current IL are based on the duty cycle for light overload (LO). The base load current IH is based on the duty cycle for high overload (HO).

3)

The input current depends on the motor load and is valid for a line impedance corresponding to uK = 1 %. The rated input currents apply for a load at the rated power (based on Irated) these current values are specified on the rating plate. Shielded motor cables must be used in order to maintain the limit values for field-conducted disturbances according to EN 61800-3 Class C2.

4)

4/70

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Characteristic curves
Derating data Ambient temperature
100 % 75 74
G_D011_EN_00111

Installation altitude
100 % 90 80 70 60 0

Permissible output current

25

-10

10

20

30

40

50

C 60

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

G_D011_EN_00104

50

Permissible output current

High overload (HO) PM260 frame size FSD


100 % 75 74
G_D011_EN_00111

4
100 % Permissible input voltage 90 80 77 70 60 0

Permissible output current

25

-10

10

20

30

40

50

C 60

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

High overload (HO) PM260 frame size FSF

System operating voltage


Permissible output current 100 % Rated power 75 66
G_D011_EN_00110

100 % 90
G_D011_EN_00117

50 25

80 70 450 65 = 690 60 400


^

-10

10

20

30

40

50

C 60

Ambient temperature

450

500

600

Light overload (LO) PM260 frame size FSD


100 % Permissible output current 75
G_D011_EN_00206

690 700 V 760 Line operating voltage

800

The power units can be operated with 500 V 10 %. In this case, the power is reduced linearly as required.

51 50 25

-10

10

20

30

40 50 C 60 Ambient temperature

Light overload (LO) PM260 frame size FSF

Note: The operating temperature ranges of the Control Units should be taken into account. The temperature ranges are specified in the technical specifications under Control Units.

Siemens D 11.1 2009

4/71

G_D011_EN_00105

50

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules 11 kW to 55 kW (15 hp to 75 hp)

Dimensional drawings
204 (8.03) 275 (10.83) 235 (9.25) 8.5 (0.33)
11 (0.43) 419 (16.5)

455 (17.91)

Drill pattern

4
G_D011_EN_00118

PM260 Power Module frame size FSD with and without integrated class A line filter

Mounted with 4 M6 studs, 4 M6 nuts, 4 M6 washers. Ventilation clearance required at top and bottom: 300 mm (11.81 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

316 (12.44)

350 (13.78)

300 (11.81) 8.5 (0.33)

634 (24.96)

Drill pattern

G_D011_EN_00098

PM260 Power Module frame size FSF with and without integrated line filter class A

Mounted with 4 M8 studs, 4 M8 nuts, 4 M8 washers. Ventilation clearance required at top and bottom: 350 mm (13.78 inches). Ventilation clearance required at sides: 0 mm (0 inches).

When the Control Unit is plugged on, the mounting depth increases by 56 mm (2.2 inches). Exception: for CU240E, mounting depth +22 mm (+0.87 inches). All dimensions in mm (values in brackets are in inches).

4/72

Siemens D 11.1 2009

598 (23.54)

11 (0.43)

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Compact inverters 0.37 kW to 15 kW (0.5 hp to 20 hp)

Overview
The entry into SINAMICS G120 with an already assembled compact inverter Three components can be ordered, completely assembled, with one Order No.: The PM240 Power Module with integrated brake choppers, the CU240E Control Unit and the BOP operator panel. The compact inverter is suitable for applications in which the advantages of a compact inverter prevail (only one Order No., simpler to order). In this case, the advantages of a consistently modular system no longer apply (lower stockkeeping, high degree of flexibility). The individual components of the compact inverter still remain completely modular. After they have been received, they can be separated at any time.

Example: Compact inverters, SINAMICS G120 with PM240 Power Module frame size FSB, CU240E Control Unit and BOP

Selection and ordering data


Rated power 1) Power based on the base load current IH2) Frame size and dimensions (H W D) mm FSA 173 73 177
new new new new new

SINAMICS G120 compact inverter without integrated line filter Order No. 6SL3214-3AE13-7UB0 6SL3214-3AE15-5UB0 6SL3214-3AE17-5UB0 6SL3214-3AE21-1UB0 6SL3214-3AE21-5UB0 6SL3214-3AE22-2UB0 6SL3214-3AE23-0UB0 6SL3214-3AE24-0UB0 6SL3214-3AE25-5UB0 6SL3214-3AE27-5UB0 6SL3214-3AE31-1UB0
new new new new new new

SINAMICS G120 compact inverter with integrated class A line filter Order No. 6SL3214-3AE22-2AB0 6SL3214-3AE23-0AB0 6SL3214-3AE24-0AB0 6SL3214-3AE25-5AB0 6SL3214-3AE27-5AB0 6SL3214-3AE31-1AB0

kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0

hp 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.0 10 15 20

kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11.0

hp 0.50 0.75 1.0 1.5 2.0 3.0 4.0 5.0 7.5 10 15

47 63 Hz 380 480 V 3 AC 10 %

FSB 270 153 204

new new new

FSC 334 189 224

new new new

1)

Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for light overload (LO). These current values are stamped on the rating plate of the Power Module.

2)

The base load current IH is based on the duty cycle for high overload (HO).

Siemens D 11.1 2009

4/73

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line filters

Overview
With one of the additional line filters, the Power Module reaches a higher radio interference class.

Selection and ordering data


Rated power kW hp SINAMICS G120 PM240 Power Module Type 6SL3224-... 0BE13-7UA0 0BE15-5UA0 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0XE41-6UA0 0XE42-0UA0 Frame size Class A line filter acc. to EN 55011 Order No.

380 480 V 3 AC
0.37 0.55 0.75 1.1 1.5 110 132 160 200 250 0.50 0.75 1.0 1.5 2.0 150 200 250 300 400 FSA FSA FSA FSA FSA FSF FSF FSGX FSGX FSGX
new new

6SE6400-2FA00-6AD0

6SL3203-0BE32-5AA0 6SL3000-0BE34-4AA0 6SL3000-0BE36-0AA0

Rated power kW Example: Line filter for Power Modules frame size FSA 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11 15 0.50 0.75 1.0 1.5 2 3 4 5 10 15 20 hp

SINAMICS G120 PM240 Power Module Type 6SL3224-... 0BE13-7UA0 0BE15-5UA0 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2AA0 0BE23-0AA0 0BE24-0AA0 0BE25-5AA0 0BE27-5AA0 0BE31-1AA0 Frame size

Class B line filter acc. to EN 55011 Order No.

380 480 V 3 AC
FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC 6SL3203-0BD23-8SA0 6SL3203-0BE21-6SA0 6SE6400-2FB00-6AD0

Rated power kW Example: Line filter for PM240 Power Modules frame size FSGX hp

SINAMICS G120 PM250 Power Module Type 6SL3225-... 0BE25-5AA0 0BE27-5AA0 0BE31-1AA0 Frame size

Class B line filter acc. to EN 55011 Order No.

380 480 V 3 AC
7.5 11 15 10 15 20 FSC FSC FSC 6SL3203-0BD23-8SA0

4/74

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line filters

Integration
Frame size FSA of the PM240 Power Module is available only without integrated class A line filter. A base filter is therefore available so that class A can be achieved. A class B base filter is also available so that class B can be achieved. Frame sizes FSB and FSC of the PM240 Power Module are available both with and without integrated class A line filter. For compliance with class B, PM240 Power Modules with integrated class A line filter must be fitted additionally with a base filter to class B. An external class A line filter is available for frame size FSGX of the PM240 Power Module. Frame sizes FSC of the PM250 Power Module are available only with integrated class A line filter. For compliance with class B, PM250 Power Modules must be fitted additionally with a class B base filter. No additional Class B line filters are available for the PM260 Power Module.

Line filters which are optionally available depending on the Power Module used
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


F/S 1) S 1)

Available frame sizes Line filter, class A Line filter, class B Available frame sizes Line filter, class A Line filter, class B Available frame sizes Line filter, class A Line filter, class B U S I F = = = = =

Line-side power components U U F U F U F F

PM250 Power Module with line-commutated energy recovery


Line-side power components I U F F F

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter
Line-side power components F F

Base component Lateral mounting Integrated Not possible Power Modules available with and without integrated class A filter

1)

PM240 FSF Power Modules, from 110 kW (150 hp) and higher and FSGX are available only without an integrated class A filter. An optional class A line filter for side mounting is available instead.

Siemens D 11.1 2009

4/75

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line filters

Technical specifications
Line supply voltage 380 480 V 3 AC Rated current Line supply connection L1, L2, L3 Conductor cross-section Load connection U, V, W Conductor cross-section Length PE connection mm2 A Line filter class A 6SE6400-2FA00-6AD0 6 Screw terminals 2.5 Shielded cable mm2 m 3 2.5 0.4 On housing with M4 screw studs IP20 mm mm mm kg Type 73 200 42.5 yes 0.5 6SL3224-0BE13-7UA0 6SL3224-0BE15-5UA0 6SL3224-0BE17-5UA0 6SL3224-0BE21-1UA0 6SL3224-0BE21-5UA0 FSA 6SL3203-0BE32-5AA0 250 On housing with M8 screw studs On housing with M8 screw studs Flat connector for M10 screw IP00 240 360 116 no 12.4 6SL3224-0BE38-8UA0 6SL3224-0BE41-1UA0 6SL3000-0BE34-4AA0 440 1 hole for M10 Provided for busbar connection On housing with M10 screw studs 1 hole for M8 IP00 360 240 116 no 12.3 6SL3224-0XE41-3UA0 6SL3224-0XE41-6UA0 6SL3000-0BE36-0AA0 600 1 hole for M10 Provided for busbar connection On housing with M10 screw studs 1 hole for M10 IP00 400 265 140 no 19 6SL3224-0XE42-0UA0

Degree of protection Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module

Suitable for PM250 Power Module Frame size

FSF

FSGX

FSGX

Line supply voltage 380 480 V 3 AC Rated current Line supply connection L1, L2, L3 Conductor cross-section Load connection U, V, W Conductor cross-section Length PE connection Degree of protection Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm A

Line filter class B 6SE6400-2FB00-6AD0 6 Screw terminals mm2 2.5 Shielded cable mm2 m 3 2.5 0.4 On housing with M4 screw studs IP20 73 200 42.5 yes 0.5 6SL3224-0BE13-7UA0 6SL3224-0BE15-5UA0 6SL3224-0BE17-5UA0 6SL3224-0BE21-1UA0 6SL3224-0BE21-5UA0 6SL3203-0BE21-6SA0 10.2 Screw terminals 2.5 Shielded cable 3 2.5 0.4 On housing with M4 screw studs IP20 153 296 50 yes 1.5 6SL3224-0BE22-2AA0 6SL3224-0BE23-0AA0 6SL3224-0BE24-0AA0 6SL3203-0BD23-8SA0 39.4 Screw terminals 4 Shielded cable 34 0.4 On housing with M4 screw studs IP20 190 362 55 yes 2.3 6SL3224-0BE25-5AA0 6SL3224-0BE27-5AA0 6SL3224-0BE31-1AA0

Suitable for PM250 Power Module

6SL3225-0BE25-5AA0 6SL3225-0BE27-5AA0 6SL3225-0BE31-1AA0 FSC

Frame size

FSA

FSB

4/76

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line reactors

Overview
A line reactor reduces the system perturbations caused by harmonics. This particularly applies in the case of weak line supplies (line supply short-circuit power uK > 1 %).

Example: Power Module frame size FSB with base line reactor and shield bonding plate

Note: A line reactor must not be used in combination with a PM250 or PM260 Power Module.
Example: Line reactors for Power Modules frame sizes FSA to FSE

Benefits
Only AC reactors are available as reactors for the inverter. Only an AC reactor provides protection for the input rectifier of the inverter. The capacitor lifetime of the inverter increases when using an AC reactor by a factor of 2 when compared to the lifetime when using a DC reactor. The harmonic behavior of AC reactors remain almost constant over the complete lifetime. Over time (months), the harmonic behavior of DC reactors changes. An AC reactor reduces possible dissymmetries between the current phases. In this case, a DC reactor would not be effective.

Example: Line reactor for PM240 Power Modules frame size FSGX

Siemens D 11.1 2009

4/77

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line reactors

Selection and ordering data


Rated power kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 110 132 160 200 250 hp 0.50 0.75 1.0 1.5 2 3 4 5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 SINAMICS G120 PM240 Power Module Type 6SL3224-... 0BE13-7UA0 0BE15-5UA0 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2 . A0 0BE23-0 . A0 0BE24-0 . A0 0BE25-5 . A0 0BE27-5 . A0 0BE31-1 . A0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0XE41-6UA0 0XE42-0UA0 Frame size FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF FSF FSF FSGX FSGX FSGX
new new

Line reactor Order No. 6SE6400-3CC00-2AD3 6SE6400-3CC00-4AD3 6SE6400-3CC00-6AD3 6SL3203-0CD21-0AA0 6SL3203-0CD21-4AA0 6SL3203-0CD22-2AA0 6SL3203-0CD23-5AA0 6SL3203-0CJ24-5AA0 6SL3203-0CD25-3AA0 6SL3203-0CJ28-6AA0 6SE6400-3CC11-2FD0 6SE6400-3CC11-7FD0 6SL3000-0CE32-3AA0 6SL3000-0CE32-8AA0 6SL3000-0CE33-3AA0 6SL3000-0CE35-1AA0

380 480 V 3 AC

Integration
The line reactors for PM240 Power Modules, frame sizes FSA to FSE, are designed as base components. The line reactor is attached to the mounting surface and the Power Module is mounted directly on the line reactor in a space-saving fashion. The cables to the Power Module are already connected at the line reactor. The line reactor is connected to the line supply through terminals.

Line reactors which are optionally available depending on the Power Module used
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


Available frame sizes Line reactor Available frame sizes Line reactor 1) Available frame sizes Line reactor 1) U = Base component S = Lateral mounting = Not possible
1)

Line-side power components U U U 1) U 1) 1) U 1) S 1) 1) S

PM250 Power Module with line-commutated energy recovery


Line-side power components

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter
Line-side power components

A line reactor is not required and must not be used in conjunction with a PM250 or PM260 Power Module.

4/78

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Rated current Power loss at 50/60 Hz, approx. Line supply connection U1, V1, W1 Conductor cross-section Load connection Conductor cross-section Length, approx. PE connection Degree of protection Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module Frame size kg Type mm mm mm 75.5 200 50 yes 0.6 6SL3224-0BE13-7UA0 6SL3224-0BE15-5UA0 FSA 75.5 200 50 yes 0.8 6SL3224-0BE17-5UA0 6SL3224-0BE21-1UA0 FSA 75.5 200 50 yes 0.6 6SL3224-0BE21-5UA0 FSA 153 290 50 yes 3.4 6SL3224-0BE22-2 . A0 6SL3224-0BE23-0 . A0 FSB m mm2 A W Line reactor 6SE6400-3CC00-2AD3 1.9 6/7 Screw terminals 6 Cable 4 AWG16 (1.5 mm2) 0.38 On housing with M5 screw studs IP20 6SE6400-3CC00-4AD3 3.5 12.5/15 Screw terminals 6 Cable 4 AWG16 (1.5 mm2) 0.38 On housing with M5 screw studs IP20 6SE6400-3CC00-6AD3 4.8 7.5/9 Screw terminals 6 Cable 4 AWG16 (1.5 mm2) 0.38 On housing with M5 screw studs IP20 6SL3203-0CD21-0AA0 9 9/11 Screw terminals 6 Cable 4 AWG16 (1.5 mm2) 0.46 On housing with M5 screw studs IP20

Line supply voltage 380 480 V 3 AC Rated current Power loss at 50/60 Hz, approx. Line supply connection U1, V1, W1 Conductor cross-section Load connection Conductor cross-section Length, approx. PE connection Degree of protection Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module Frame size kg Type mm mm mm m mm2 A W

Line reactor 6SL3203-0CD21-4AA0 11.6 27/32 Screw terminals 6 Cable 4 AWG16 (1.5 mm2) 0.46 On housing with M5 screw studs IP20 153 290 50 yes 3.4 6SL3224-0BE24-0 . A0 FSB 6SL3203-0CD22-2AA0 25 98/118 Screw terminals 6 Cable 4 AWG10 (2.5 mm2) 0.49 On housing with M5 screw studs IP20 189 371 50 yes 5.2 6SL3224-0BE25-5 . A0 6SL3224-0BE27-5 . A0 FSC 6SL3203-0CD23-5AA0 31.3 37/44 Screw terminals 16 Cable 4 AWG10 (2.5 mm2) 0.49 On housing with M5 screw studs IP20 189 371 50 yes 5.9 6SL3224-0BE31-1 . A0 FSC 6SL3203-0CJ24-5AA0 47 90/115 Screw terminals 16 Cable 4 16 mm2 0.7 On housing with M8 screw IP20 275 455 84 yes 13 6SL3224-0BE31-5 . A0 6SL3224-0BE31-8 . A0 FSD

Siemens D 11.1 2009

4/79

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Line reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Line reactor 6SL32030CD25-3AA0 Rated current Power loss at 50/60 Hz, approx. Line supply connection U1, V1, W1 Conductor cross-section Load connection mm2 A W 63 90/115 6SL32030CJ28-6AA0 94 170/215 6SE64003CC11-2FD0 151 280/360 6SE64003CC11-7FD0 186 280/360 Flat connector for M10 cable lug Flat connector for M10 cable lug 6SL30000CE32-3AA0 224 240/270 Flat connector for M10 screw Flat connector for M10 screw 6SL30000CE32-8AA0 278 210/250 Flat connector for M10 screw Flat connector for M10 screw M6 screw IP00 270 248 200 no 24 6SL32240BE41-1UA0

Screw terminals Screw terminals Flat connector for M10 cable lug 16 Cable 50 Cable Flat connector for M10 cable lug

Conductor cross-section Length, approx. PE connection Degree of protection Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module

mm2 m

4 16 0.7

4 35 0.7

On housing with On housing with On housing with On housing with M6 screw M8 screw M8 screw M8 screw stud M8 screw stud IP20 mm mm mm kg Type 275 455 84 yes 13 6SL32240BE32-2 . A0 IP20 275 577 94 yes 19 6SL32240BE33-0 . A0 6SL32240BE33-7 . A0 FSE IP00 240 228 141 no 25 6SL32240BE34-5 . A0 6SL32240BE35-5 . A0 FSF IP00 240 228 141 no 25 6SL32240BE37-5 . A0 IP00 270 248 200 no 24 6SL32240BE38-8UA0

Frame size

FSD

FSF

FSF

FSF

Line supply voltage 380 480 V 3 AC Rated current Power loss at 50/60 Hz, approx. Line supply connection U1, V1, W1 Conductor cross-section Load connection Conductor cross-section PE connection Degree of protection Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module Frame size kg Type mm mm mm mm2 mm2 A W

Line reactor 6SL3000-0CE33-3AA0 331 0.267 1 hole for M10 provided for busbar connection provided for busbar connection M6 screw IP00 270 248 200 no 27.8 6SL3224-0XE41-3UA0 FSGX 6SL3000-0CE33-5AA0 508 0.365 1 hole for M12 provided for busbar connection provided for busbar connection M6 screw IP00 300 269 212 no 38.0 6SL3224-0XE41-6UA0 6SL3224-0XE42-0UA0 FSGX

4/80

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Recommended line components

Overview
The following table lists recommendations for additional lineside components, such as fuses and circuit breakers (line-side components dimensioned in accordance with IEC standards). The specified circuit breakers are UL-certified. 3NA3 fuses are recommended for European countries. The 3NE1 fuses are UL-compliant (corresponds to RU). The values in the table take into account the overload capability of the inverter. Additional information about the listed fuses and circuit breakers can be found in Catalogs LV 1 and LV 1 T.

Selection and ordering data


Rated power SINAMICS G120 PM240 Power Modules Type 6SL3224-... 0BE13-7UA0 0BE15-5UA0 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2 . A0 0BE23-0 . A0 0BE24-0 . A0 0BE25-5 . A0 0BE27-5 . A0 0BE31-1 . A0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0BE41-6UA0 0BE42-0UA0 Frame size FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF FSF FSF FSGX FSGX FSGX
new new new

Fuse Type 3NA3 Type 3NE1 (RU) Order No. UL-listed fuses such as the Class NON fuse series from Bussmann are required for North America.

Circuit breaker

kW 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 110 132 160 200 250

hp 0.50 0.75 1.0 1.5 2 3 4 5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400

Order No. 3NA3803

Order No. 3RV1021-1CA10 3RV1021-1DA10 3RV1021-1FA10 3RV1021-1GA10 3RV1021-1JA10 3RV1021-1KA10 3RV1021-4AA10 3RV1021-4BA10 3RV1031-4EA10 3RV1031-4FA10 3RV1031-4HA10

380 480 V 3 AC

3NA3805 3NA3807 3NA3812 3NA3814 3NA3820 3NA3822 3NA3824 3NA3830 3NA3832 3NA3836 3NA3140 3NA3144 3NA3254 3NA3260 3NA3372
new new

3NE1817-0 3NE1818-0 3NE1820-0 3NE1021-0 3NE1022-0 3NE1224-0 3NE1225-0 3NE1227-0 3NE1230-0 3NE1333-2 3NE1436-2
new new

3RV1042-4KA10 3RV1042-4MA10 3VL1712-.DD33-.... 3VL1716-.DD33-.... 3VL3720-.DC36-.... 3VL3725-.DC36-.... 3VL4731-.DC36-....

3VL4740-.DC36-.... 3VL5750-.DC36-....

Siemens D 11.1 2009

4/81

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Line-side power components Recommended line components

Selection and ordering data


Rated power SINAMICS G120 PM250 Power Modules Type 6SL3225-... 0BE25-5AA0 0BE27-5AA0 0BE31-1AA0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 Frame size FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF Fuse Type 3NA3 kW 7.5 11.0 15.0 18.5 22 30 37 hp 10 15 20 25 30 40 50 60 75 100 125 Order No. 3NA3807 3NA3812 3NA3814 3NA3820 3NA3822 3NA3824 3NA3830 3NA3832 3NA3836 3NA3140 3NA3144 Type 3NE1 (RU) Order No. UL-listed fuses such as the Class NON fuse series from Bussmann are required for North America. 3NE1817-0 3NE1818-0 3NE1820-0 3NE1021-0 3NE1022-0 3NE1224-0 3NE1225-0 3NE1227-0 3RV1042-4MA10 3VL1712-.DD33-.... 3VL1716-.DD33-.... 3VL3720-.DC36-.... 3VL3725-.DC36-.... 3VL4731-.DC36-.... Order No. 3RV1031-4EA10 3RV1031-4FA10 3RV1031-4HA10 3RV1042-4KA10 Circuit breaker

380 480 V 3 AC

45 55 75 90

Rated power

SINAMICS G120 PM260 Power Modules Type 6SL3225-... 0BH27-5 . A1 0BH31-1 . A1 0BH31-5 . A1 0BH32-2 . A1 0BH33-0 . A1 0BH33-7 . A1 Frame size FSD FSD FSD FSF FSE FSF

Fuse Type 3NA3 Type 3NE1 (RU) Order No.

Circuit breaker

kW 11.0 15.0 18.5 30 37 55

hp 15 20 25 40 50 75

Order No. 3NA3120-6

Order No. 3RV1041-4FA10

500 690 V 3 AC

3NA3122-6 3NA3130-6

3RV1041-4JA10 3RV1041-4KA10 3RV1041-4MA10

4/82

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
DC link components Braking resistors

Overview

The braking resistors can be installed at the side of the PM240 Power Modules. The braking resistors for the FSA and FSB frame sizes are designed as base components. If the PM240 Power Modules, frame size FSA or FSB, are operated without line reactor, the braking resistors can also be installed under the Power Modules. The braking resistors for the Power Modules, frame sizes FSC to FSGX, should be placed outside the control cabinet or outside the switchgear room so that the heat is dissipated away from the Power Modules. The level of air conditioning required is therefore reduced. Every braking resistor has a temperature switch (UL-listed). The temperature switch can be evaluated to prevent consequential damage if the braking resistor overheats.

Selection and ordering data


Rated power kW hp SINAMICS G120 PM240 Power Module Type 6SL3224-... Frame size Braking resistor Order No.

380 480 V 3 AC
0.37 0.55 0.75 Example: Braking resistors for Power Modules, frame sizes FSA and FSC 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 37 45 55 75 Example: Braking resistor for PM240 Power Modules frame size FSGX 90 110 132 160 200 250 0.50 0BE13-7UA0 0.75 0BE15-5UA0 1.0 1.5 2 3 4 5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2 . A0 0BE23-0 . A0 0BE24-0 . A0 0BE25-5 . A0 0BE27-5 . A0 0BE31-1 . A0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0XE41-6UA0 0XE42-0UA0 FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF FSF FSF FSGX 1) FSGX FSGX 1)
new new

6SE6400-4BD11-0AA0

6SL3201-0BE12-0AA0

6SE6400-4BD16-5CA0

6SE6400-4BD21-2DA0

6SE6400-4BD22-2EA1 6SE6400-4BD24-0FA0

Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are intended for use with PM240 Power Modules which feature an integrated brake chopper, but cannot regenerate energy to the supply system. There is an optional plug-in Braking Module for frame size FSGX. For generator operation, e.g. the braking of a rotating mass with high moment of inertia, a braking resistor must be connected to convert the resulting energy into heat.

6SE6400-4BD26-0FA0 6SL3000-1BE31-3AA0 6SL3000-1BE32-5AA0

1) new

1)

A Braking Module must be additionally ordered for connection.

Siemens D 11.1 2009

4/83

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
DC link components Braking resistors

Integration
Braking resistors which are optionally available depending on the Power Module used
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


Available frame sizes DC link components Braking resistor Available frame sizes DC link components

S 1)

S 1) 1)

S 1)

S 1) 1)

PM250 Power Module with line-commutated energy recovery

Braking resistor 1) Available frame sizes DC link components Braking resistor 1) U = Base component S = Lateral mounting = Not possible

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter

Technical specifications
Line supply voltage 380 V 480 V 3 AC Resistor Rated power PDB Peak power Pmax (cycle time 12 s) Power connections Conductor cross-section Length Thermostatic switch (NC contact) Max. contact load Degree of protection Frame size Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 72 230 43.5 yes 1 6SL3224-0BE13-7UA0 6SL3224-0BE15-5UA0 6SL3224-0BE17-5UA0 6SL3224-0BE21-1UA0 6SL3224-0BE21-5UA0 FSA 153 329 43.5 yes 2 6SL3224-0BE22-2.A0 6SL3224-0BE23-0.A0 6SL3224-0BE24-0.A0 185 285 150 no 3.8 6SL3224-0BE25-5.A0 6SL3224-0BE27-5.A0 6SL3224-0BE31-1.A0 mm2 m kW (hp) kW Braking resistor 6SE6400-4BD11-0AA0 390 0.1 (0.13) 2 Shielded cable 3 2.5 0.5 250 V AC/2.5 A IP20 FSA 6SL3201-0BE12-0AA0 160 0.2 (0.27) 4 Shielded cable 3 2.5 0.5 250 V AC/2.5 A IP20 FSB 6SE6400-4BD16-5CA0 56 0.65 (0.87) 11 Shielded cable 3 2.5 0.9 250 V AC/2.5 A IP20 FSC

Frame size

FSB

FSC

1)

Line-commutated energy recovery is possible in conjunction with a PM250 or PM260 Power Module. A braking resistor cannot be connected and is not necessary.

4/84

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
DC link components Braking resistors

Technical specifications
Line supply voltage 380 V 480 V 3 AC Braking resistor 6SE64004BD21-2DA0 Resistor Rated power PDB Peak power Pmax (cycle time 12 s) Power connections Thermostatic switch (NC contact) Max. contact load Degree of protection Frame size Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 270 515 175 no 7.4 6SL3224-0BE31-5.A0 6SL3224-0BE31-8.A0 6SL3224-0BE32-2.A0 FSD 326 301 484 no 11 6SL3224-0BE33-0.A0 6SL3224-0BE33-7.A0 FSE 395 650 315 no 16.7 6SL3224-0BE34-5.A0 6SL3224-0BE35-5.A0 6SL3224-0BE37-5.A0 FSF 526 301 484 no 17.5 6SL3224-0BE38-8UA0 6SL3224-0BE41-1UA0 FSF kW (hp) kW 27 1.2 (1.6) 24 M6 screw studs 250 V AC/2.5 A IP20 FSD 6SE64004BD22-2EA1 15 2.2 (3.0) 44 M6 screw studs 250 V AC/2.5 A IP20 FSE 6SE64004BD24-0FA0 8.2 4 (5) 80 M6 screw studs 250 V AC/2.5 A IP20 FSF 6SE64004BD26-0FA0 5.5 5.6 (7.5) 120 M6 screw studs 250 V AC/2.5 A IP20 FSF

Frame size

Line supply voltage 380 V 480 V 3 AC Resistor Rated power PDB Peak power Pmax (cycle time 15 s every 90 s) Power connections Thermostatic switch (NC contact) Max. contact load Degree of protection Frame size Dimensions Width Height Depth Possible as base component Weight, approx. Suitable for PM240 Power Module Frame size kg Type mm mm mm kW (hp) kW

Braking resistor 6SL3000-1BE31-3AA0 4.4 25 (34) 125 M10 screw stud 250 V AC/2.5 A IP20 FSGX 740 605 485 no 50 6SL3224-0XE41-3UA0 FSGX 6SL3000-1BE32-5AA0 2.2 50 (67) 250 M10 screw stud 250 V AC/2.5 A IP20 FSGX 810 1325 485 no 120 6SL3224-0XE41-6UA0 6SL3224-0XE42-0UA0 FSGX

Siemens D 11.1 2009

4/85

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
DC link components Braking Modules

Overview

The Braking Module is designed for installation in PM240 Power Modules, frame size FSGX and is cooled by the Power Module fan. The supply voltage for the electronics is taken from the DC link. The Braking Module is connected to the DC link using the busbar sets included in the scope of delivery. The activation threshold of the Braking Module can be adjusted by means of a DIP switch. The braking power values specified in the technical specifications apply to the upper activation threshold.

Selection and ordering data


Description Order No.
new

DC link voltage 510 720 V DC


Braking Module 50 kW/250 kW 6SL3300-1AE32-5AA0

4
A Braking Module and the matching external braking resistor are required to bring drives to a controlled standstill in the event of a power failure (e.g. emergency retraction or EMERGENCY STOP Category 1) or limit the DC link voltage for brief periods of generator operation. The Braking Module includes the power electronics and the associated control circuit. During operation, the DC link energy is converted to heat loss in an external braking resistor. Braking Modules function autonomously.

Design
The Braking Module has the following interfaces as standard: 1 DC link connection 1 braking resistor connection 1 digital input (inhibit Braking Module/acknowledge fault) 1 digital output (Braking Module inhibited) 1 DIP switch for adjusting the activation threshold

Integration

Braking Module
X21 +24 V
21.6

Fault output
21.5

Fault

0V
21.4

Inhibit input
21.3

Inhibit

0V
21.2

Shield
21.1

Braking resistor R1

T1

DCPA Connection to DC link

R2

T2
DCNA
G_D211_EN_00012b

Connection example of a Braking Module

4/86

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
DC link components Braking Modules

Technical specifications
DC link voltage 510 720 V DC Power Rated power PDB Peak power P15 Power P20 Power P40 Activation thresholds (adjustable via DIP switch) Length of cable to braking resistor, max. Digital inputs In accordance with IEC 61131-2 Type 1 Voltage Low level (an open-circuit digital input is interpreted as low) High Level Current consumption at 24 V DC, typ. Max. conductor cross-section Digital outputs (continuously short-circuit proof) Voltage Load current per digital output, max. Max. conductor cross-section R1/R2 connection Max. conductor cross-section Weight, approx. Approvals Suitable for installation in a PM240 Power Module 24 V DC 500 mA 1.5 mm2 M8 screw 50 mm2 7.3 kg cURus (File No.: E192450) Frame size FSGX 3 +30 V 3 +5 V 15 30 V 10 mA 1.5 mm2 50 kW (67 hp) 250 kW 200 kW 100 kW 774 V (factory setting) or 673 V 50 m Braking Module 6SL3300-1AE32-5AA0

Siemens D 11.1 2009

4/87

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Overview
Output reactors reduce the voltage stress on the motor windings. At the same time, the capacitive charging/discharging currents, which place an additional load on the power unit when long motor cables are used, are reduced. Output reactors are only provided for the PM240 and PM250 Power Modules. An output reactor is not required for the PM260 Power Module due to its integrated sine-wave filter. The maximum permissible output frequency is 150 Hz when an output reactor is used the pulse frequency must not exceed 4 kHz. The output reactor must be installed as close as possible to the Power Module. Output reactors are approved for use only in conjunction with Vector and V/f control modes.

Selection and ordering data


Rated power kW hp SINAMICS G120 PM240 Power Modules Type 6SL3224-... Output reactor Frame size Order No.

380 480 V 3 AC
0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 110 132 160 200 250 0.50 0BE13-7UA0 0.75 0BE15-5UA0 1.0 1.5 2 3 4 5 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2 . A0 0BE23-0 . A0 0BE24-0 . A0 0BE25-5 . A0 0BE27-5 . A0 0BE31-1 . A0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0XE41-6UA0 0XE42-0UA0 FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF FSF FSF FSGX FSGX FSGX
new new new

6SE6400-3TC00-4AD2

6SL3202-0AE21-0CA0

6SL3202-0AJ23-2CA0

6SE6400-3TC05-4DD0 6SE6400-3TC03-8DD0 6SE6400-3TC05-4DD0 6SE6400-3TC08-0ED0 6SE6400-3TC07-5ED0 6SE6400-3TC14-5FD0 6SE6400-3TC15-4FD0 6SE6400-3TC14-5FD0 6SL3000-2BE32-1AA0 6SL3000-2BE32-6AA0 6SL3000-2BE33-2AA0 6SL3000-2BE33-8AA0 6SL3000-2BE35-0AA0

Rated power Example: Output reactors for Power Modules frame sizes FSA and FSB kW hp

SINAMICS G120 PM250 Power Modules Type 6SL3225-... 0BE25-5AA0 0BE27-5AA0 0BE31-1AA0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0

Output reactor

Frame size Order No.

380 480 V 3 AC
7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 10 15 20 25 30 40 50 60 75 100 125 FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF 6SE6400-3TC05-4DD0 6SE6400-3TC03-8DD0 6SE6400-3TC05-4DD0 6SE6400-3TC08-0ED0 6SE6400-3TC07-5ED0 6SE6400-3TC14-5FD0 6SE6400-3TC15-4FD0 6SE6400-3TC14-5FD0 6SL3202-0AJ23-2CA0

Example: Output reactor for PM240 Power Modules frame size FSGX

4/88

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Integration
Output reactors which are optionally available depending on the Power Module used The following line-side power components, DC link components and load-side power components are optionally available in the appropriate frames sizes for the Power Modules:
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


Available frame sizes Output reactor Available frame sizes Output reactor Available frame sizes Output reactor 1) U = Base component S = Lateral mounting = Not possible

Load-side power components U U U S S S S

PM250 Power Module with line-commutated energy recovery


Load-side power components U S S S

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter
Load-side power components

1)

PM260 Power Modules do not require output reactors as they are already equipped with sine-wave filters.

Siemens D 11.1 2009

4/89

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Rated current Power loss Connection to the Power Module Conductor cross-section Length, approx. Motor connection Conductor cross-section mm2 PE connection Cable length, max. between output reactor and motor 380 V ( 10 %) ... 400 V 3 AC - Shielded - Unshielded 401 V... 480 V (+ 10 %) 3 AC - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size kg Type mm mm mm 75.5 200 110 yes IP00 2 6SL32240BE13-7UA0 75.5 200 110 yes IP00 2 6SL32240BE15-5UA0 0.55 (0.75) 1.7 FSA 75.5 200 110 yes IP00 2 6SL32240BE17-5UA0 0.75 (1.0) 2.2 FSA 75.5 200 110 yes IP00 2 6SL32240BE21-1UA0 1.1 (1.5) 3.1 FSA 75.5 200 110 yes IP00 2 6SL32240BE21-5UA0 1.5 (2.0) 4.1 FSA m m 100 150 100 150 100 150 100 150 100 150 m m 150 225 150 225 150 225 150 225 150 225 m A kW Output reactor (for a 4 kHz pulse frequency) 6SE6400-3TC00-4AD2 4 0.005 Cable 4 AWG16 (1.5 mm2) 0.3 Screw terminals 6 M5 screw studs 4 0.005 Cable 4 AWG16 (1.5 mm2) 0.3 Screw terminals 6 M5 screw studs 4 0.005 Cable 4 AWG16 (1.5 mm2) 0.3 Screw terminals 6 M5 screw studs 4 0.005 Cable 4 AWG16 (1.5 mm2) 0.3 Screw terminals 6 M5 screw studs 4 0.005 Cable 4 AWG16 (1.5 mm2) 0.3 Screw terminals 6 M5 screw studs

kW (hp) 0.37 (0.5) A 1.3 FSA

4/90

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Rated current Power loss Connection to the Power Module Conductor cross-section Length, approx. Motor connection Conductor cross-section PE connection Cable length, max. between output reactor and motor 380 V (10 %) ... 400 V 3 AC - Shielded - Unshielded 401 V ... 480 V (+10 %) 3 AC - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 154 270 70 yes IP00 4.4 6SL32240BE22-2UA0 6SL32240BE22-2AA0 154 270 70 yes IP00 4.4 6SL32240BE23-0UA0 6SL32240BE23-0AA0 3 (4) 7.7 FSB 154 270 70 yes IP00 4.4 6SL32240BE24-0UA0 6SL32240BE24-0AA0 4 (5) 10.2 FSB 189 334 80 yes IP00 9.1 6SL32240BE25-5UA0 6SL32240BE25-5AA0 6SL32250BE25-5AA0 7.5 (10) 18 FSC 189 334 80 yes IP00 9.1 6SL32240BE27-5UA0 6SL32240BE27-5AA0 6SL32250BE27-5AA0 11 (15) 25 FSC 189 334 80 yes IP00 9.1 6SL32240BE31-1UA0 6SL32240BE31-1AA0 6SL32250BE31-1AA0 15 (20) 32 FSC m m 100 150 100 150 100 150 100 150 100 150 100 150 m m 150 225 150 225 150 225 150 225 150 225 150 225 mm2 m A kW Output reactor (for a 4 kHz pulse frequency) 6SL3202-0AE21-0CA0 9.4 0.02 Cable 4 AWG14 (1.5 mm2) 0.4 Screw terminals 6 M5 screw studs 9.4 0.02 Cable 4 AWG14 (1.5 mm2) 0.4 Screw terminals 6 M5 screw studs 9.4 0.02 Cable 4 AWG14 (1.5 mm2) 0.4 Screw terminals 6 M5 screw studs 6SL3202-0AJ23-2CA0 32 0.06 Cable 4 AWG14 (1.5 mm2) 0.35 Screw terminals 6 M5 screw studs 32 0.06 Cable 4 AWG14 (1.5 mm2) 0.35 Screw terminals 6 M5 screw studs 32 0.06 Cable 4 AWG14 (1.5 mm2) 0.35 Screw terminals 6 M5 screw studs

Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size

Type

kW (hp) 2.2 (3.0) A 5.9 FSB

Siemens D 11.1 2009

4/91

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Output reactor (for a 4 kHz pulse frequency) 6SE64003TC05-4DD0 Rated current Power loss Connection to the Power Module Motor connection PE connection Cable length, max. between output reactor and motor 380 V ( 10 %) ... 400 V 3 AC - Shielded - Unshielded 401 V ... 480 V (+ 10 %) 3 AC - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 225 210 150 no IP00 10.7 6SL32240BE31-5UA0 6SL32240BE31-5AA0 6SL32250BE31-5 . A0 225 210 179 no IP00 16.1 6SL32240BE31-8UA0 6SL32240BE31-8AA0 6SL32250BE31-8 . A0 22 (30) 45 FSD 225 210 150 no IP00 10.7 6SL32240BE32-2UA0 6SL32240BE32-2AA0 6SL32250BE32-2 . A0 30 (40) 60 FSD 225 210 150 no IP00 10.4 6SL32240BE33-0UA0 6SL32240BE33-0AA0 6SL32250BE33-0 . A0 37 (50) 75 FSE 270 248 209 no IP00 24.9 6SL32240BE33-7UA0 6SL32240BE33-7AA0 6SL32250BE33-7 . A0 45 (60) 90 FSE m m 200 300 200 300 200 300 200 300 200 300 m m 200 300 200 300 200 300 200 300 200 300 A kW 68 1) 0.2 Flat connector for M6 cable lug Flat connector for M6 cable lug M6 screw 6SE64003TC03-8DD0 45 1) 0.2 Flat connector for M6 cable lug Flat connector for M6 cable lug M6 screw 6SE64003TC05-4DD0 68 1) 0.2 Flat connector for M6 cable lug Flat connector for M6 cable lug M6 screw 6SE64003TC08-0ED0 104 1) 0.17 Flat connector for M6 cable lug Flat connector for M6 cable lug M6 screw 6SE64003TC07-5ED0 90 1) 0.27 Flat connector for M6 cable lug Flat connector for M6 cable lug M6 screw

Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size

Type

kW (hp) 18.5 (25) A 38 FSD

1)

On the rating plate of the reactor the current is displayed according to High Overload HO, which is lower than the indicated value for the Light Overload current of the Power Module.

4/92

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Output reactor (for a 4 kHz pulse frequency) 6SE64003TC14-5FD0 Rated current Power loss Connection to the Power Module Motor connection PE connection Cable length, max. between output reactor and motor 380 V ( 10 %) ... 400 V 3 AC - Shielded - Unshielded 401 V ... 480 V (+ 10 %) 3 AC - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 350 321 288 no IP00 51.5 6SL32240BE34-5UA0 6SL32240BE34-5AA0 6SL32250BE34-5 . A0 270 248 209 no IP00 24 6SL32240BE35-5UA0 6SL32240BE35-5AA0 6SL32250BE35-5 . A0 75 (100) 145 FSF 350 321 288 no IP00 51.5 6SL32240BE37-5UA0 6SL32240BE37-5AA0 6SL32250BE37-5 . A0 90 (125) 178 FSF 300 285 257 no IP00 60 6SL32240BE38-8UA0 300 315 277 no IP00 66 6SL32240BE41-1UA0 m m 200 300 200 300 200 300 200 300 200 300 m m 200 300 200 300 200 300 200 300 200 300 A kW 178 1) 0.47 Flat connector for M8 cable lug Flat connector for M8 cable lug M8 screw 6SE64003TC15-4FD0 178 1) 0.25 Flat connector for M8 cable lug Flat connector for M8 cable lug M6 screw 6SE64003TC14-5FD0 178 1) 0.47 Flat connector for M8 cable lug Flat connector for M8 cable lug M8 screw 6SL30002BE32-1AA0 210 0.49 Flat connector for M10 screw Flat connector for M10 screw M8 screw 6SL30002BE32-6AA0 260 0.5 Flat connector for M10 screw Flat connector for M10 screw M8 screw

Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size

Type

110 (150) 205 FSF

132 (200) 250 FSF

kW (hp) 55 (75) A 110 FSF

1)

On the rating plate of the reactor the current is displayed according to High Overload HO, which is lower than the indicated value for the Light Overload current of the Power Module.

Siemens D 11.1 2009

4/93

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Output reactors

Technical specifications
Line supply voltage 380 480 V 3 AC Rated current Power loss Connection to the Power Module Motor connection PE connection Cable length, max. between output reactor and motor A kW Output reactor (for a 4 kHz pulse frequency) 6SL3000-2BE33-2AA0 310 0.470 1 hole for M10 1 hole for M10 M6 screw 6SL3000-2BE33-8AA0 380 0.500 1 hole for M10 1 hole for M10 M6 screw 6SL3000-2BE35-0AA0 490 0.500 1 hole for M12 1 hole for M12 M6 screw

380 V ( 10 %) ... 400 V 3 AC - Shielded - Unshielded 401 V ... 480 V (+ 10 %) 3 AC - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size kg Type Type mm mm mm 300 285 257 no IP00 66 6SL3224-0XE41-3UA0 300 285 277 no IP00 73 6SL3224-0XE41-6UA0 200 (300) 370 FSGX 300 365 277 no IP00 100 6SL3224-0XE42-0UA0 250 (400) 477 FSGX m m 300 450 300 450 300 450 m m 300 450 300 450 300 450

kW (hp) 160 (250) A 302 FSGX

4/94

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Overview

Selection and ordering data


Rated power kW hp SINAMICS G120 PM240 Power Module Type 6SL3224-... Sine-wave filter Frame size Order No.

380 480 V 3 AC
0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 Example: Sine-wave filter for PM240 Power Modules frame size FSGX 37 45 55 75 90 110 132 160 200 250 0.50 0BE13-7UA0 0.75 0BE15-5UA0 1.0 1.5 2.0 3.0 4.0 5.0 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 400 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2 . A0 0BE23-0 . A0 0BE24-0 . A0 0BE25-5 . A0 0BE27-5 . A0 0BE31-1 . A0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0XE41-6UA0 0XE42-0UA0 FSA FSA FSA FSA FSA FSB FSB FSB FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF FSF FSF FSGX FSGX FSGX
new new new new new new new new new new new new new new new

6SL3202-0AE20-3SA0

6SL3202-0AE20-6SA0 6SL3202-0AE21-1SA0 6SL3202-0AE21-4SA0 6SL3202-0AE22-0SA0 6SL3202-0AE23-3SA0 6SL3202-0AE24-6SA0 6SL3202-0AE26-2SA0 6SL3202-0AE28-8SA0 6SL3202-0AE31-5SA0 6SL3202-0AE31-8SA0 6SL3000-2CE32-3AA0 6SL3000-2CE32-8AA0 6SL3000-2CE33-3AA0 6SL3000-2CE34-1AA0

A sine-wave filter limits the rate of rise of voltage and the capacitive charging/discharging currents that usually occur with inverter operation. An output reactor is not required. Sine-wave filters are only provided for the PM240 and PM250 Power Modules. PM260 Power Modules already have an integrated sine-wave filter and an additional sine-wave filter is not required. The sine-wave filter at the inverter output supplies almost perfect sinusoidal voltages at the motor so that standard motors can be used without special cables. Standard cables can be used. The maximum permissible motor feeder length is 300 m. The maximum output frequency is 150 Hz at 380 V to 480 V. When using sine-wave filters, the following should be observed: Operation with pulse frequencies from 4 kHz to 8 kHz (sinewave filter from 160 kW, only for 4 kHz) permissible It must be ensured that the automatic pulse frequency reduction functions are also deactivated A derating of 5 % must be observed when selecting a suitable inverter The output frequency is limited to 150 Hz Operation and commissioning may only be performed with the motor connected as the sine-wave filter is not no-load proof

Rated power kW hp

SINAMICS G120 PM250 Power Module Type 6SL3225-... 0BE25-5AA0 0BE27-5AA0 0BE31-1AA0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 0BE33-0 . A0 0BE33-7 . A0 0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0 Frame size

Sine-wave filter Order No.

380 480 V 3 AC
7.5 11.0 15.0 18.5 22 30 37 45 55 75 90 10 15 20 25 30 40 50 60 75 100 125 FSC FSC FSC FSD FSD FSD FSE FSE FSF FSF FSF
new new new new new new new

6SL3202-0AE22-0SA0 6SL3202-0AE23-3SA0 6SL3202-0AE24-6SA0 6SL3202-0AE26-2SA0 6SL3202-0AE28-8SA0 6SL3202-0AE31-5SA0 6SL3202-0AE31-8SA0

Siemens D 11.1 2009

4/95

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Integration
Sine-wave filters which are optionally available depending on the Power Module used
Frame size FSA FSB FSC FSD FSE FSF FSGX

PM240 Power Module with integrated brake chopper

without integrated brake chopper


Available frame sizes Sine-wave filter Available frame sizes

Load-side power components U U U S S S S

PM250 Power Module with line-commutated energy recovery


Load-side power components

Sine-wave filter Available frame sizes Sine-wave filter U S I = = = = Base component Lateral mounting Integrated Not possible

PM260 Power Module with line-commutated energy recovery and integrated sine-wave filter
Load-side power components I I

4/96

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Technical specifications
Line supply voltage 380 ... 480 V 3 AC Rated current Power loss Connection to the Power Module Conductor cross-section Length, approx. Motor connection Conductor cross-section PE connection Cable length, max. between sine-wave filter and motor 380 ... 480 V 3 AC 10 % - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size kg Type mm mm mm 75.5 200 110 yes IP20 2.6 6SL32240BE13-7UA0 75.5 200 110 yes IP20 2.6 6SL32240BE15-5UA0 0.55 (0.75) 1.7 FSA 75.5 200 110 yes IP20 2.6 6SL32240BE17-5UA0 0.75 (1.0) 2.2 FSA 75.5 200 110 yes IP20 3.0 6SL32240BE21-1UA0 1.1 (1.5) 3.1 FSA 75.5 200 110 yes IP20 3.0 6SL32240BE21-5UA0 1.5 (2.0) 4.1 FSA m m 200 300 200 300 200 300 200 300 200 300 mm2 mm2 m A kW Sine-wave filter (for pulse frequencies 4 kHz ... 8 kHz) 6SL3202-0AE20-3SA0 3.5 0.005 Cable 6 0.5 Screw terminals 6 M5 screw studs 3.5 0.005 Cable 6 0.5 Screw terminals 6 M5 screw studs 3.5 0.005 Cable 6 0.5 Screw terminals 6 M5 screw studs 6SL3202-0AE20-6SA0 6.0 0.005 Cable 6 0.5 Screw terminals 6 M5 screw studs 6.0 0.005 Cable 6 0.5 Screw terminals 6 M5 screw studs

kW (hp) 0.37 (0.5) A 1.3 FSA

Siemens D 11.1 2009

4/97

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Technical specifications
Line supply voltage 380 ... 480 V 3 AC Sine-wave filter (for pulse frequencies 4 kHz ... 8 kHz) 6SL3202-0AE21-1SA0 Rated current Power loss Connection to the Power Module Conductor cross-section Length, approx. Motor connection Conductor cross-section mm2 PE connection Cable length, max. between sine-wave filter and motor 380 ... 480 V 3 AC 10 % - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 153 270 100 yes IP20 6 6SL32240BE22-2UA0 6SL32240BE22-2AA0 153 270 100 yes IP20 6 6SL32240BE23-0UA0 6SL32240BE23-0AA0 3 (4) 7.7 FSB 153 270 100 yes IP20 10 6SL32240BE24-0UA0 6SL32240BE24-0AA0 4 (5) 10.2 FSB 189 336 140 yes IP20 12 6SL32240BE25-5UA0 6SL32240BE25-5AA0 6SL32250BE25-5AA0 7.5 (10) 18 FSC 189 336 140 yes IP20 23 6SL32240BE27-5UA0 6SL32240BE27-5AA0 6SL32250BE27-5AA0 11 (15) 25 FSC 189 336 140 yes IP20 23 6SL32240BE31-1UA0 6SL32240BE31-1AA0 6SL32250BE31-1AA0 15 (20) 32 FSC m m 200 300 200 300 200 300 200 300 200 300 200 300 mm2 m A kW 9.0 0.02 Cable 6 0.5 Screw terminals 6 M5 screw studs 9.0 0.02 Cable 6 0.5 Screw terminals 6 M5 screw studs 6SL32020AE21-4SA0 14.0 0.02 Cable 6 0.5 Screw terminals 6 M5 screw studs 6SL32020AE22-0SA0 20.0 0.06 Cable 10 0.5 10 M5 screw studs 6SL3202-0AE23-3SA0 33.0 0.06 Cable 10 0.5 10 M5 screw studs 33.0 0.06 Cable 10 0.5 Screw terminals 10 M5 screw studs

Screw terminals Screw terminals

Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size

Type

kW (hp) 2.2 (3) A 5.9 FSB

4/98

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Technical specifications
Line supply voltage 380 ... 480 V 3 AC Sine-wave filter (for pulse frequencies 4 kHz ... 8 kHz) 6SL3202-0AE24-6SA0 Rated current Power loss Connection to the Power Module Conductor cross-section Motor connection Conductor cross-section PE connection Cable length, max. between sine-wave filter and motor 380 ... 480 V 3 AC 10 % - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 250 315 262 no IP00 24.0 6SL32240BE31-5UA0 6SL32240BE31-5AA0 6SL32250BE31-5 . A0 250 315 262 no IP00 24.0 6SL32240BE31-8UA0 6SL32240BE31-8AA0 6SL32250BE31-8 . A0 22 (30) 45 FSD 250 305 262 no IP00 34.0 6SL32240BE32-2UA0 6SL32240BE32-2AA0 6SL32250BE32-2 . A0 30 (40) 60 FSD 275 368 275 no IP00 45.0 6SL32240BE33-0UA0 6SL32240BE33-0AA0 6SL32250BE33-0 . A0 37 (50) 75 FSE 275 368 275 no IP00 45.0 6SL32240BE33-7UA0 6SL32240BE33-7AA0 6SL32250BE33-7 . A0 45 (60) 90 FSE m m 200 300 200 300 200 300 200 300 200 300 mm2 mm2 A kW 47 0.2 Screw terminals 50 Screw terminals 50 M6 screw 47 0.2 Screw terminals 50 Screw terminals 50 M6 screw 6SL32020AE26-2SA0 61.8 0.2 Screw terminals 50 Screw terminals 50 M6 screw 6SL3202-0AE28-8SA0 92 0.17 Screw terminals 95 Screw terminals 95 M8 screw 92 0.27 Screw terminals 95 Screw terminals 95 M8 screw

Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size

Type

kW (hp) 18.5 (25) A 38 FSD

Siemens D 11.1 2009

4/99

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Technical specifications
Line supply voltage 380 ... 480 V 3 AC Sine-wave filter (for pulse frequencies 4 kHz ... 8 kHz, from 160 kW only 4 kHz) 6SL3202-0AE31-5SA0 Rated current Power loss Connection to the Power Module Conductor cross-section Motor connection Conductor cross-section PE connection Cable length, max. between sine-wave filter and motor 380 ... 480 V 3 AC 10 % - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module kg Type mm mm mm 350 440 305 no IP00 63.0 6SL32240BE34-5UA0 6SL32240BE34-5AA0 6SL32250BE34-5 . A0 350 440 305 no IP00 63.0 6SL32240BE35-5UA0 6SL32240BE35-5AA0 6SL32250BE35-5 . A0 75 (100) 145 FSF 350 468 305 no IP00 80.0 6SL32240BE37-5UA0 6SL32240BE37-5AA0 6SL32250BE37-5 . A0 90 (125) 178 FSF 620 300 320 no IP00 124 6SL32240BE38-8UA0 620 300 320 no IP00 124 6SL32240BE41-1UA0 m m 200 300 200 300 200 300 300 450 300 450 mm2 mm2 A kW 150 0.47 Screw terminals 150 Screw terminals 150 M8 screw 150 0.25 Screw terminals 150 Screw terminals 150 M6 screw 6SL32020AE31-8SA0 182 0.47 Screw terminals 150 Screw terminals 150 M8 screw 1 hole for M10 1 hole for M10 1 hole for M10 1 hole for M10 6SL3000-2CE32-3AA0 225 0.6 1 hole for M10 225 0.6 1 hole for M10

Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size

Type

110 (150) 205 FSF

132 (200) 250 FSF

kW (hp) 55 (75) A 110 FSF

4/100

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Load-side power components Sine-wave filters

Technical specifications
Line supply voltage 380 ... 480 V 3 AC Rated current Power loss Connection to the Power Module Motor connection PE connection Cable length, max. between sine-wave filter and motor 380 ... 480 V 3 AC 10 % - Shielded - Unshielded Dimensions Width Height Depth Possible as base component Degree of protection Weight, approx. Suitable for PM240 Power Module Suitable for PM250 Power Module Rated power of the Power Module Rated current Irated of the Power Module Frame size kg Type Type mm mm mm 620 300 320 no IP00 127 6SL3224-0XE41-3UA0 620 370 360 no IP00 136 6SL3224-0XE41-6UA0 200 (300) 370 FSGX 620 370 360 no IP00 198 6SL3224-0XE42-0UA0 250 (400) 477 FSGX m m 300 450 300 450 300 450 A kW Sine-wave filter (for pulse frequencies 4 kHz ... 8 kHz, from 160 kW only 4 kHz) 6SL3000-2CE32-8AA0 276 0.69 1 hole for M10 1 hole for M10 1 hole for M10 6SL3000-2CE33-3AA0 333 0.53 1 hole for M10 1 hole for M10 1 hole for M10 6SL3000-2CE34-1AA0 408 0.7 1 hole for M10 1 hole for M10 1 hole for M10

kW (hp) 160 (250) A 302 FSGX

Siemens D 11.1 2009

4/101

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Intelligent Operator Panel IOP

Overview
Intelligent Operator Panel IOP IOP Handheld

4
The Intelligent Operator Panel IOP is an extremely user-friendly and powerful Operator Panel for the SINAMICS G120, SINAMICS G120D standard drives and SIMATIC ET 200 frequency converters. The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, the menu prompting and the Application Wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list as the parameters are displayed in plain text and due to the explanatory help texts and the parameter filtering function. Application Wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors. There are quick commissioning wizards for general commissioning. The drives are manually and simply controlled using directly assigned buttons and the navigation wheel. The IOP has a dedicated switchover button to switch over from the automatic to the manual mode. The frequency inverter can be diagnosed in a user-friendly fashion using the plain text display of faults and alarms. Help texts can be obtained by pressing the INFO button. Up to two process values can either be graphically or numerically visualized on the status screen/status display. Process values can also be displayed in technological units. IOP supports series commissioning of identical drives. For this purpose, a parameter list can be copied from a frequency inverter into the IOP and when required, downloaded into other drive units of the same type. The IOP includes the following language packages: English, French, German, Italian and Spanish. The IOP can be installed in control cabinet doors using the optionally available door mounting kit. Updating the IOP The IOP can be updated and expanded using the integrated USB interface. Data to support future drive systems can be transferred from the PC to the IOP via drag & drop. Further, the USB interface allows user languages and wizards that become available in the future to be subsequently downloaded and the firmware to be updated for the IOP. The IOP is supplied with power via the USB interface during an update. A handheld version of the IOP can be ordered for mobile use. In addition to the IOP, this includes a housing with rechargeable batteries, charging unit and RS232 interface cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 8 hours. A PC Inverter Connection Kit 6SL3255-0AA00-2AA1 is required to connect the IOP to the CU240S and CU240E Control Units. To connect the IOP Handheld to SINAMICS G110D and SINAMICS G120D, the RS232 interface cable with optical interface is additionally required.

Benefits
7 7 7 7 7 7 7 7 7 7 7

7 7

Simple commissioning of standard applications using wizards, it is not necessary to know the parameter structure Diagnostics using plain text display; can be used locally onsite without documentation Direct manual operation of the drive you can toggle between the automatic and manual modes Status display with freely selectable units; display of real physical values Intuitive, navigation using a wheel just like in everyday applications Graphic display for e.g. status values in bar-type diagrams such as e.g. pressure, flow Quickly and simply mounted in the door mechanically and electrically Simple local commissioning on-site using the handheld version Commissioning without documentation using the integrated help function Series commissioning using the clone function (parameter set data is saved for fast replacement) User-defined parameter list with a reduced number of self-selected parameters (to generate your own commissioning screens) 5 integrated languages Simple update of languages, wizards and firmware updates via USB

4/102

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Intelligent Operator Panel IOP

Selection and ordering data


Designation Intelligent Operator Panel IOP IOP Handheld For use with SINAMICS G120, SINAMICS G110D, SINAMICS G120D, SIMATIC ET 200S FC or SIMATIC ET 200pro FC Included in the scope of delivery: IOP Handheld housing Rechargeable batteries (4 AA) Charging unit (international) RS232 connecting cable (3 m long, can only be used for SINAMICS G120 and SIMATIC ET 200S FC) USB cable (1 m long)
new new

Accessories
Order No. 6SL3255-0AA00-4JA0 6SL3255-0AA00-4HA0 Designation IOP Door Mounting Kit IP54 degree of protection for mounting the IOP in control cabinet doors with sheet steel thicknesses of 1 3 mm Included in the scope of delivery: Seal Mounting material Connecting cable (5 m long) RS232 interface cable With optical interface to connect the SINAMICS G110D, SINAMICS G120D or SIMATIC ET 200pro FC inverters to the IOP Handheld (2.5 m long)
new

Order No. 6SL3256-0AP00-0JA0

3RK1922-2BP00

Integration
Using the IOP with the frequency inverters
IOP SINAMICS G120 with CU230P-2 Control Unit SINAMICS G120 with CU240E or CU240S Control Unit PC Inverter Connection Kit required, 6SL3255-0AA00-2AA1 SINAMICS G110D and SINAMICS G120D RS232 interface cable with optical interface required, 3RK1922-2BP00

Plugging the IOP onto the inverter (power supply from the Control Unit) IOP door mounting with door mounting kit (power supply from the Control Unit) Mobile use of the IOP Handheld (supplied from rechargeable batteries)

Mounting the IOP on a CU230P-2 Control Unit The IOP can be directly plugged onto the CU230P-2 Control Unit.

Mounting the IOP in a door Using the optionally available door mounting kit, the IOP can be simply mounted in a control cabinet door with just a few manual operations (presently only available in conjunction with the SINAMICS G120 and CU230P-2 Control Unit). Degree of protection IP54/UL Type 12 is achieved when mounting in a door.

Door panel Door mounting bracket Screws Seal IOP

D-type retaining screws

CU230P-2 Control Unit with plugged on IOP

G_D011_EN_00207

Siemens D 11.1 2009

4/103

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Basic Operator Panel BOP

Overview

Selection and ordering data


Order No. Basic Operator Panel BOP (not for Control Unit CU230P-2) 6SL3255-0AA00-4BA1

Integration

The Basic Operator Panel BOP can be used to commission drives, monitor drives in operation and input individual parameter settings. Values and units are displayed on a 5-digit display. One BOP can be used for several inverters. It is plugged directly onto the CU240 Control Unit. The BOP provides a function to quickly copy parameters. A parameter set of an inverter can be saved in the BOP and then downloaded to another inverter. Note: The BOP is not suitable for the CU230P-2 Control Unit. The Intelligent Operator Panel IOP is available for this purpose.

Example: CU240E Control Unit with mounted Basic Operator Panel BOP

4/104

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components MMC memory card

Overview

Integration

The parameter settings for an inverter can be stored on the MMC memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again. Parameter settings can be written from the MMC memory card to the inverter or saved from the inverter to the MMC memory card. Up to 100 parameter sets can be stored. Supports series commissioning without the use of additional commissioning tools (e.g. BOP and STARTER). Commissioning with the MMC memory card is defined by the user: - Parameter p8458 = 0 parameter set 0 is never automatically downloaded from the MMC (never) - Parameter p8458 = 1 parameter set 0 is downloaded once after PowerOn (once) - Parameter p8458 = 2 parameter set 0 is always downloaded after PowerOn (always) Note: The MMC memory card is not required for operation and does not have to remain inserted. Note: The CU240E Control Unit does not have a slot for the MMC memory card.

Example: Inserting the MMC memory card into a CU240 Control Unit

Selection and ordering data


Order No. MMC memory card (not for the CU240E Control Unit) 6SL3254-0AM00-0AA0

Example: CU240 Control Unit with inserted MMC memory card

Siemens D 11.1 2009

4/105

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components CM240NE chemical industry module

Applications
Inverters for 400 V, 500 V and 690 V are required in the chemical industry that meet the special demands and requirements of this industry sector. The essential requirements and demands of the chemical industry are fulfilled using the SINAMICS G120 series of inverters supplemented by the CM240NE chemical industry module (with ATEX-certified PTC evaluation and a NAMUR terminal strip). Sine-wave filter integrated in the PM260 Power Modules (500 V to 690 V) A line reactor is not required for the PM260 and PM250 Power Modules PM250 and PM260 Power Modules are capable of energy recovery A series of inverters for the complete voltage and power range The integrated or external sine-wave filter permits unshielded motor cables up to 300 m; shielded motor cables are possible up to 200 m (carefully observe the max. length of the temperature sensor cable!) An extremely compact overall drive system can be achieved when using a PM260 Power Module, frame size FSD or FSF (the line reactor and sine-wave filter are not required, the chemical industry module is directly snapped onto the Power Module).

CM240NE chemical industry module

Selection and ordering data


Order No. CM240NE chemical industry module
new

6SL3255-0BT01-0PA0

Accessories
Order No. Supplementary kit for rail mounting comprising Adapter for rail mounting (acc. to DIN 50022, 35 15 mm) Long cable harness
new

6SL3260-4TA00-1AA6

CM240NE chemical industry module without cover

The CM240NE chemical industry module has the following interfaces:


Designation PROFIBUS X11 and X12 X2 Description 9-pin, Sub-D connector or socket to connect PROFIBUS Parallel connection of the CM240NE chemical industry module with the Control Unit Terminal strip in accordance with NAMUR recommendation NE37 (2.5 mm2 screw terminals) Digital inputs and outputs Analog inputs and outputs Terminal strip in accordance with NAMUR recommendation NE37 (2.5 mm2 screw terminals) to connect the motor temperature sensor

Design
Compact, modular inverter Isolated analog inputs and outputs in the chemical industry module (1 setpoint / 2 measured values) Isolated digital inputs and outputs in the Control Unit Protective separation of the motor sensor cable with respect to the enclosure and other connections using reinforced insulation of the creepage and clearances (rated impulse voltage 12 kV) acc. to EN 60664 1 Certified power disconnection (94/9/EC, ATEX) of the inverter without main contactor Forced inverter inhibit (EMERGENCY STOP function via STO) Terminal strip acc. to NE37, if fulfilled

X3

Function
Thermal motor protection (TMP) using the the PTC thermistor integrated in the motor (incl. protective separation up to 690 V line supplies) The analog inputs and outputs are electrically isolated (MW1 to 3) Provision of NAMUR terminal strip (-X2; -X3)

4/106

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components CM240NE chemical industry module

Integration
A chemical industry inverter comprises a SINAMICS G120 inverter (Power Module and Control Unit) and the CM240NE chemical industry module. The CU240S DP-F is suitable as Control Unit. This is a Control Unit with integrated safety-oriented functions and PROFIBUS-DP interface. The following Power Module versions are used: PM240 Power Module with DC braking function and brake chopper, 400 V line supply voltage PM250 Power Module with energy recovery capability, 400 V line supply voltage PM260 Power Module with energy recovery capability, 500 V to 690 V line supply voltage Depending on the power unit, additional components may be necessary to complete the system.

Additional information
A script file to parameterize the interconnections in line with the NAMUR assignment is available as download to commission the system using the STARTER commissioning tool. German: http://support.automation.siemens.com/WW/view/de/30814192 English: http://support.automation.siemens.com/WW/view/en/30814192

Chemical industry inverter comprising PM240 Power Module, CU240S DP-F Control Unit with BOP and CM240NE chemical industry module

Siemens D 11.1 2009

4/107

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components PC Inverter Connection Kit -2 Supplementary system components PC Inverter Connection Kit

Overview
For controlling and commissioning an inverter directly from a PC, if the STARTER commissioning tool has been installed on the PC. With these, the inverter can be parameterized (commissioning, optimization) monitored (diagnostics) controlled (master control via the STARTER commissioning tool for test purposes). A USB cable (3 m) and the STARTER commissioning tool 1) are included as scope of delivery on a DVD.

Overview

Selection and ordering data


Order No.

PC Inverter Connection Kit -2 for CU230P-2 Control Units Including USB cable (3 m) and STARTER commissioning tool 1) on DVD

new

6SL3255-0AA00-2CA0

Example: PC Connection Kit for CU240 Control Units

For controlling and commissioning an inverter directly from a PC, if the STARTER commissioning tool has been installed on the PC. With these, the inverter can be parameterized (commissioning, optimization) monitored (diagnostics) controlled (master control via the STARTER commissioning tool for test purposes). This is an isolated RS232 adapter board for a reliable point-topoint connection to a PC with a serial RS232 interface. A USB/RS232 adapter can be used as an alternative (e.g. type 12.02.1086R supplied by Roline). The scope of delivery includes a 9-pin Sub-D connector, an RS232 standard cable (3 m) and the STARTER commissioning tool 1) on DVD.

Selection and ordering data


Order No. PC Inverter Connection Kit 6SL3255-0AA00-2AA1 Including a 9-pin Sub-D connector, an RS232 standard cable (3 m), and the STARTER commissioning tool 1) on DVD

1)

The STARTER commissioning tool is also available in the Internet under http://support.automation.siemens.com/WW/view/en/10804985/133100

4/108

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Brake Relay

Overview

The Brake Relay allows the Power Module to be connected to an electromechanical motor brake, thereby allowing the motor brake to be driven directly by the Control Unit.

Selection and ordering data


Order No. Brake Relay 6SL3252-0BB00-0AA0 Including cable harness for connection to the Power Module

Integration
The Brake Relay has the following interfaces: A switch contact (NO contact) to control the motor brake solenoid A connection for the cable harness (CTRL) for connection to the Power Module The Brake Relay can be installed on the shield bonding plate near the power terminals of the Power Module. The supplied Brake Relay includes the cable harness for connection with the Power Module.

PM-IF interface

Power Module

Cable harness

CTRL

G_D211_EN_00070

Voltage supply motor brake

Connection example of a Brake Relay

Technical specifications
Brake Relay Max. switching capability of the NO contact Max. conductor cross-section Degree of protection Dimensions Width Height Depth Weight, approx. 440 V AC / 3.5 A 30 V DC / 12 A 2.5 mm2 IP20 68 mm 63 mm 33 mm 0.17 kg

U2 V2 W2 PE

Brake Relay

M 3~

Siemens D 11.1 2009

4/109

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Safe Brake Relay

Overview

The Safe Brake Relay allows the Power Module to be safely connected to an electromechanical motor brake, allowing the brake to be directly and safely controlled by the Control Unit in accordance with EN 954-1 Safety Category 3 and IEC 61508 SIL 2.

Selection and ordering data


Order No. Safe Brake Relay 6SL3252-0BB01-0AA0 Including cable harness for connection to the Power Module

Integration

The Safe Brake Relay has the following interfaces: A two-channel transistor output stage to control the motor brake solenoid A connection for a 24 V DC power supply A connection for the cable harness (CTRL) for connection to the Power Module

The Safe Brake Relay can be mounted on the shield bonding plate near the power terminals of the Power Module. The supplied Safe Brake Relay includes the cable harness for connection with the Power Module. The 24 V DC solenoid of the motor brake is directly connected to the Safe Brake Relay. External surge suppressors are not required.

PM-IF interface

Power Module

Cable harness

+ ext. 24 V M

+ + M M CTRL BRBR+

G_D211_EN_00071

Connection example of a Safe Brake Relay

Technical specifications
Safe Brake Relay Supply voltage 20.4 28.8 V DC Recommended rated value of the 26 V DC supply voltage (to equalize and compensate for the voltage drop along the feeder cable to the 24 V DC solenoid of the motor brake) 2A 0.005 A + the current requirement of motor brake Degree of protection Dimensions Width Height Depth Weight, approx. Safe Brake Relay Max. conductor cross-section 2.5 mm2 IP20 68 mm 63 mm 33 mm 0.17 kg

Max. current requirement of motor brake Current requirement at 24 V DC, max.

4/110

Siemens D 11.1 2009

U2 V2 W2 PE

Safe Brake Relay

M 3~

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Adapter for mounting on DIN rails Supplementary system components Shield Connection Kit

Overview
The adapter for DIN rail mounting can be used to mount inverters, frame sizes FSA and FSB on DIN mounting rails (2 units with a center-to-center distance of 100 mm). Furthermore, the motor cable shield connection and other cable shields required for mounting inverters on DIN rails comply with the same standards for emissions and conducted emissions as if the inverter were directly installed in a control cabinet. The adapter for inverter frame size FSA can be used to mount converters singly or with matching line filter. The adapter for inverter frame size FSB can be used to mount inverters with or without an integrated line filter.

Overview

Selection and ordering data


Adapter for mounting on DIN rails for Power Module frame size FSA for Power Module frame size FSB Order No. 6SL3262-1BA00-0BA0 6SL3262-1BB00-0BA0

Example of Shield Connection Kit for Power Module frame size FSB

The Shield Connection Kit makes it easier to connect the shields of supply and control cables provides mechanical strain relief ensures optimum EMC performance is used to attach the Brake Relay and Safe Brake Relay The Shield Connection Kit includes a shield bonding plate for the required Power Module a shield bonding plate for a CU240 Control Unit connection elements and clamps for mounting mounting device for Brake Relay or Safe Brake Relay frame sizes FSB to FSF

Selection and ordering data


Shield Connection Kit for PM240/PM250 Power Modules - Frame size FSA - Frame size FSB - Frame size FSC - Frame sizes FSD and FSE - Frame size FSF for PM260 Power Modules - Frame size FSD - Frame size FSF 6SL3262-1FD00-0CA0 6SL3262-1FF00-0CA0 6SL3262-1AA00-0BA0 6SL3262-1AB00-0DA0 6SL3262-1AC00-0DA0 6SL3262-1AD00-0DA0 6SL3262-1AF00-0DA0 Order No.

Siemens D 11.1 2009

4/111

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Supplementary system components Shield Connection Kit 1 for CU230P-2 Supplementary system components Shield Connection Kit for CU240S Control Units

Overview
The Shield Connection Kit 1 for CU230P-2 Control Units offers for all signal and communication cables Optimum shield connection Strain relief It contains the following: A matching shield bonding plate All of the necessary connecting and retaining elements for mounting The Shield Connection Kit 1 is suitable for the following SINAMICS G120 Control Units: CU230P-2 HVAC CU230P-2 DP CU230P-2 CAN

Overview
The Shield Connection Kit for CU240S Control Units offers for all signal and communication cables Optimum shield connection Strain relief It contains the following: A matching shield bonding plate All of the necessary connecting and retaining elements for mounting The Shield Connection Kit is suitable for the following SINAMICS G120 Control Units: CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F

Selection and ordering data


Order No. Shield Connection Kit 1 for CU230P-2 Control Units
new

6SL3264-1EA00-0FA0

Selection and ordering data


Order No. Shield Connection Kit For CU240S Control Units
new

6SL3264-1EA00-0EA0

4/112

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Spare parts CU240 Spare Parts Kit Spare parts Spare door for PM240 frame size FSGX

Overview
The CU240 Spare Parts Kit includes: A replacement cover to cover the terminals A matching shield bar for the CU240E Control Unit, incl. screws A replacement connector for the CU240S Control Unit A protective element for the MMC card slot Screws to attach the shield bonding plate of the CU240S Control Unit The CU240 Spare Parts Kit is suitable for the following SINAMICS G120 Control Units: CU240E CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F

Overview
Complete replacement door for the PM240 Power Module frame size FSGX

Selection and ordering data


Order No. Replacement door for PM240 Power Module frame size FSGX
new

6SL3200-0SM10-0AA0

Selection and ordering data


Order No. CU240 Spare Parts Kit For CU240E and CU240S Control Units
new

6SL3200-0SK00-0AA0

Siemens D 11.1 2009

4/113

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Spare parts Terminal Cover Kit for frame sizes FSD and FSE Spare parts Terminal Cover Kit for frame size FSF

Overview
The Terminal Cover Kit includes a replacement cover for the connecting terminals. The Terminal Cover Kit is suitable for the following SINAMICS G120 Power Modules: PM240 frame sizes FSD and FSE PM250 frame sizes FSD and FSE

Overview
The Terminal Cover Kit includes a replacement cover for the connecting terminals. The Terminal Cover Kit is suitable for the following SINAMICS G120 Power Modules: PM240 frame size FSF PM250 frame size FSF PM260 frame size FSF

Selection and ordering data


Order No. Terminal Cover Kit for frame sizes FSD and FSE
new

Selection and ordering data


Order No. Terminal Cover Kit for frame size FSF
new

6SL3200-0SM11-0AA0

6SL3200-0SM12-0AA0

4/114

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Spare parts Spare connector

Overview
Replacement connector for the input and output sides. The replacement connector is suitable for the following SINAMICS G120 PM260 Power Modules frame size FSD.

Selection and ordering data


Order No. Replacement connector for PM260 Power Modules frame size FSD
new

6SL3200-0ST04-0AA1

Siemens D 11.1 2009

4/115

Siemens AG 2009

SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
Spare parts Replacement fan

Overview
The Power Module fans are designed for extra long service life. Replacement fans can be ordered for special applications.

Selection and ordering data


Rated power kW hp SINAMICS G120 PM240 Power Module Type 6SL3224-... Frame size and number of fans FSA, 1 fan Replacement fan Order No. Rated power kW hp SINAMICS G120 PM250 Power Module Type 6SL3225-... Frame size and number of fans FSC, 2 fans 1) Replacement fan Order No.

380 480 V 3 AC
0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 7.5 11.0 15.0 18.5 22 30 0.50 0BE13-7UA0 0.75 0BE15-5UA0 1.0 1.5 2 3 4 5 10 15 20 25 30 40 0BE17-5UA0 0BE21-1UA0 0BE21-5UA0 0BE22-2 . A0 0BE23-0 . A0 0BE24-0 . A0 0BE25-5 . A0 0BE27-5 . A0 0BE31-1 . A0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 FSD, 2 fans FSC, 2 fans 1) 6SL3200-0SF03-0AA0 (includes 1 replacement fan) 6SL3200-0SF04-0AA0 (includes 2 replacement fans) 6SL3200-0SF05-0AA0 (includes 2 replacement fans) FSE, 2 fans 6SL3200-0SF04-0AA0 (includes 2 replacement fans) 6SL3200-0SF05-0AA0 (includes 2 replacement fans) FSF, 2 fans 6SL3200-0SF06-0AA0 (includes 2 replacement fans) 6SL3200-0SF07-0AA0 (includes 2 replacement fans) 6SL3200-0SF08-0AA0 (includes 2 replacement fans) FSGX, 2 fans
new

380 480 V 3 AC
6SL3200-0SF01-0AA0 (includes 1 replacement fan) 7.5 11.0 15.0 18.5 22 FSB, 2 fans 1) 30 10 15 20 25 30 40 0BE25-5AA0 0BE27-5AA0 0BE31-1AA0 0BE31-5 . A0 0BE31-8 . A0 0BE32-2 . A0 FSD, 2 fans 6SL3200-0SF03-0AA0 (includes 1 replacement fan) 6SL3200-0SF04-0AA0 (includes 2 replacement fans) 6SL3200-0SF05-0AA0 (includes 2 replacement fans) FSE, 2 fans 6SL3200-0SF04-0AA0 (includes 2 replacement fans) 6SL3200-0SF05-0AA0 (includes 2 replacement fans) FSF, 2 fans 6SL3200-0SF06-0AA0 (includes 2 replacement fans) 6SL3200-0SF08-0AA0 (includes 2 replacement fans)

37

50

0BE33-0 . A0

45

60

0BE33-7 . A0

55 75 90

75 100 125

0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0

37

50

0BE33-0 . A0

45

60

0BE33-7 . A0

Rated power kW hp

SINAMICS G120 PM260 Power Module Type 6SL3225-... Frame size and number of fans FSD, 2 fans
new

Replacement fan Order No.

55 75 90

75 100 125

0BE34-5 . A0 0BE35-5 . A0 0BE37-5 . A0

660 690 V 3 AC
11.0 15.0 18.5 30 37 55 15 20 25 40 50 75 0BH27-5 . A1 0BH31-1 . A1 0BH31-5 . A1 0BH32-2 . A1 0BH33-0 . A1 0BH33-7 . A1 FSF, 2 fans 6SL3200-0SF11-0AA0 (includes 2 replacement fans) 6SL3200-0SF07-0AA0 (includes 2 replacement fans)

110 132 160 200 250

150 200 250 300 400

0BE38-8UA0 0BE41-1UA0 0XE41-3UA0 0XE41-6UA0 0XE42-0UA0

6SL3362-0AG00-0AA1 (includes 2 replacement fans)

1)

Recommended: Even if only one fan on the Power Module is defective, it is advisable to replace both. In this case, the order quantity must be doubled.

4/116

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)


5/2 5/2 5/2 5/3 5/3 5/4 5/5 5/6 5/6 5/10 5/11 5/13 5/13 5/13 5/14 5/14 5/15 5/15 5/16 5/16 5/17 5/17 5/17 5/17

SINAMICS G110D distributed inverters Overview Applications Selection and ordering data Benefits Design Integration Configuration Technical specifications Characteristic curves Dimensional drawings Recommended line components Overview Selection and ordering data DC link components Braking resistors Supplementary system components Intelligent Operator Panel IOP Handheld Manual-local control with keyswitch MMC memory card Card holder for MMC/SD memory card RS232 interface cable for communication with a PC USB interface cable for communication with a PC Adapter to mount SINAMICS G110D instead of SIRIUS M200D motor starter STARTER commissioning tool AS-Interface connecting cables Connecting cables for digital inputs Connecting cables pre-fabricated at one end and connector sets to connect to the line supply Motor cables pre-fabricated at one end and connector sets to connect the inverter to the motor Power bus distribution 400 V in IP65 degree of protection Additional information Spare parts Spare Parts Kit Replacement fan

5/17 5/18 5/18 5/18

5/19

5/19 5/19 5/20 5/20 5/20

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Overview
The new SINAMICS G110D distributed frequency inverter series is the solution for basic drive tasks especially in the field of conveyor systems. The inverter allows the speed of three-phase asynchronous motors to be continually controlled and fulfills the requirements of conveyor-related applications with open-loop frequency control. It can be optimally integrated into the system thanks to its compact and low-profile design in an IP65 degree of protection. This drive can be optimally integrated into the Siemens TIA world of automation via AS-Interface. With its wide power range from 0.75 kW to 7.5 kW (1.0 hp to 10 hp), it is suitable for a wide range of distributed drive solutions.

Device design SINAMICS G110D is a compact inverter in IP65 degree of protection where the Control Unit (CU) and Power Module (PM) function units are combined in one device. The closed-loop control electronics controls and monitors the power electronics in several different control types that can be selected. The digital inputs and analog inputs on the device mean that sensors can be simply and directly connected at the drive. The input signals can either be directly linked within the closed-loop control or they can be transferred to the central control via AS-Interface for further processing within the context of the overall system. The power electronics supplies the motor in the power range 0.75 kW to 7.5 kW (1.0 hp to 10 hp). It is controlled (open-loop) from the microprocessor-based control. State-of-the-art IGBT technology with pulse-width-modulation is used for highly reliable and flexible motor operation. It also features an extensive range of functions offering a high degree of protection for the inverter and motor. The unusually low profile mechanical design is optimized so that the device can be directly used in the plant or system. The compact inverter has the same drilling dimensions for all of the power ratings (standard footprint); further, the dimensions are identical to those of the SINAMICS G120D frequency inverter. This significantly simplifies the mechanical design and retrofitting of the system. The latest technical documentation (catalogs, dimensional drawings, certificates, manuals and operating instructions), are available on the Internet under: http://www.siemens.com/sinamics-g110d/documentation and offline on the DVD CA 01 in the SD Configurator. In addition, the SD Configurator can be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com/dt-configurator STARTER commissioning tool The STARTER commissioning tool (from STARTER Version 4.1.3 and higher) supports the commissioning and maintenance of SINAMICS G110D inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.

Example: SINAMICS G110D, frame size FSA

Reasons for using distributed drive systems Modular drive solutions therefore standardized mechatronic elements that can be individually tested A control cabinet is not required, resulting in a smaller space requirement and lower cooling requirements Long cables between the inverter and motor can be avoided (which means lower power losses, reduced noise emission and lower costs for shielded cables and additional filters) Distributed configurations offer considerable benefits for conveyor systems with their extensive coverage (e.g. in the automotive and logistics sectors) Siemens family of distributed drives Siemens offers an innovative portfolio of frequency inverters to optimally implement distributed drive solutions. The strengths of the individual members of the drive family permit simple adaptation to the widest range of application demands: Identical connection systems Identical mounting dimensions for SINAMICS G110D and SINAMICS G120D Standard commissioning and configuration tool Products from the family of distributed drives: SINAMICS G110D frequency inverters SINAMICS G120D frequency inverters SIMATIC ET 200S FC drive converters SIMATIC ET 200pro FC drive converters SIRIUS M200D motor starters

Applications
SINAMICS G110D is ideally suited for basic conveyor system applications in the industrial environment for which a distributed drive with communications capability is required. This is especially true for distribution logistics and for airports. Further, SINAMICS G110D is suitable for many additional lowperformance applications in many sectors, e.g. in the automobile sector, in the food and beverage industry (without tenside) and in the packaging industry.

5/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Selection and ordering data


Rated power 1) Rated output current 2) Input current Frame size SINAMICS G110D with integrated class A line filter Order No. FSA FSA FSA FSB FSC FSC
new new new new new new

SINAMICS G110D with integrated class A line filter and integrated maintenance switch Order No.
new new new new new new

kW 0.75 1.5 3 4 5.5 7.5

hp 1 1.5 4 5 7.5 10
4)

A
3)

A 2.0 3.8 7.0 9.1 12.2 17.9

380 500 V 3 AC

2.3 4.3 7.7 10.2 13.2 19.0

6SL3511-0PE17-5AM0 6SL3511-0PE21-5AM0 6SL3511-0PE23-0AM0 6SL3511-0PE24-0AM0 6SL3511-0PE25-5AM0 6SL3511-0PE27-5AM0

6SL3511-1PE17-5AM0 6SL3511-1PE21-5AM0 6SL3511-1PE23-0AM0 6SL3511-1PE24-0AM0 6SL3511-1PE25-5AM0 6SL3511-1PE27-5AM0

Benefits
7 7

7 7

7 7

Wide power range from 0.75 kW to 7.5 kW (1.0 hp to 10 hp) Fast commissioning and maintenance as well as extended diagnostic functions and communications capability with AS interface according to specification 3.0 - Reduced number of interfaces - Plantwide engineering - Easy to handle Mechanical design, installation and retrofit of systems are significantly simplified as a result of the compact and spacesaving design with an extremely low profile and with the same drilling dimensions for all power ratings; further, the dimensions are identical with those of the SINAMICS G120D inverter. Simple commissioning and maintenance using the same, standardized connectors for the bus, power and I/O connections (ISO 23570) for the complete power range of SINAMICS G110D and SINAMICS G120D inverters. The same connectors are used as for the SIRIUS M200D motor starter Simple, standard implementation of completely distributed plant and system concepts by using products in a scalable fashion: - SIRIUS M200D (motor starter) - SINAMICS G110D (inverter for basic, conveyor-related applications) - SINAMICS G120D (inverter for sophisticated, conveyor-related applications) High degree of operator friendliness by using the Intelligent Operator Panel (IOP) to parameterize, diagnose, control (open-loop) and copy drive parameters in the IOP Easy to replace using a plug-in design and the use of a memory card provides the highest degree of service friendliness Simple connection, configuration, data management as well as control of the inverter in complex plants and systems as a result of the consequential integration in TIA (Totally Integrated Automation)

7 7 7

7 7 7

Using the optional maintenance switch, the inverter can be simply disconnected from the line supply when service is required, without any additional components or without additional wiring costs when configuring the system Using the optional manual local control, commissioning is fast and can be limited to specific areas, the application can be manually pre-tested on site and the system can be cleared or emptied without requiring complex options. By being able to connect up to five sensors directly at the unit, practically all of the drive-relevant information can be directly managed; local pre-processing of the signals relieves the fieldbus to achieve fast and reproducible response times Integrated class A EMC filter (acc. to EN 55011) Integrated brake control, brake voltages that are supported, 400 V AC/180 V DC and 230 V AC/205 V DC Integrated motor protection using a thermal motor model and evaluation of PTC, Thermo-Click or KTY 84 temperature sensors Simple device replacement and fast copying of parameters to the memory card using the optional memory card holder and the optional MMC memory card Engineering and commissioning using standard engineering tools such as SIZER (from Version 3.2 and higher), STARTER (from Version 4.1.3 and higher) and Drive ES ensures fast configuration and simple commissioning STARTER is integrated into STEP 7 with Drive ES Basic, with all of the benefits of central data management and unified communication Software parameters for simple adaptation to 50 Hz or 60 Hz motors (IEC or NEMA motors) Increased degree of ruggedness and longer service life as the electronic modules are coated Globally certified acc. to CE, UL, c-tick

1) 2)

Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for high overload (HO). The rated output current Irated is based on the duty cycle for high overload (HO). These current values are valid for 400 V and are stamped on the rating plate.

3) 4)

With the exception of UL operation, 500 V +10 % is possible. It is not possible to make any assignment to a particular standard.

Siemens D 11.1 2009

5/3

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Design
The SINAMICS G110D distributed frequency inverters are compact frequency inverters for standard drives. Each SINAMICS G110D includes both the Control Unit as well as the Power Module in one unit. Accessories Braking resistors Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are designed for use with the SINAMICS G110D. This has an integrated brake chopper (electronic switch). Intelligent Operator Panel IOP Handheld User-friendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of SINAMICS G110D. Manual-local control with keyswitch Master control can be toggled between the automatic mode (PLC) and manual-local mode using the manual-local control. This can also be used to switch off the inverter. Additional functions include switching over between the continuous and jog mode, starting the motor including direction of rotation and deactivating the quick stop in the manual mode. MMC memory card

Example: SINAMICS G110D with integrated maintenance switch and manual-local control with keyswitch

SINAMICS G110D features an integrated brake chopper and is suitable for distributed drives without energy recovery capability. If generator energy is produced then this is dissipated in the externally connected braking resistors. The communication is realized via the local inputs (digital and analog) or via the AS-Interface bus integrated as standard.

The parameter settings for an inverter can be stored on the MMC memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again. The associated memory card holder is not included with the inverter and must be separately ordered. Card holder for the MMC memory card To use the MMC memory card, a card holder is required that is inserted under the blanking cover or under the manual-local control operator panel on the inverter. RS232 interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool from Version 4.1.3 and higher) has been installed. USB interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool from Version 4.1.3 and higher) has been installed. Adapter to mount the SINAMICS G110D instead of a SIRIUS M200D motor starter Connection Board Kit to mount a SINAMICS G110D inverter on the connection holes of the SIRIUS M200D motor starter (assuming that there is enough space). Connecting cable Connector sets to connect to the line supply and the outgoing motor feeder are available as accessories as well as pre-fabricated motor cables for connection to the motor. Flexible plug-in cables to transfer data between AS-Interface participants as well as to supply the Control Unit and the Power Module with power. Spare Parts Kit A Spare Parts Kit is available which comprises small parts such as seals, caps and screws. Replacement fan A replacement fan is available, which comprises a pre-mounted unit with cover, fan and screws.

Example: SINAMICS G110D with integrated maintenance switch

The inverter is available in 2 versions: with or without maintenance switch. Using the optional maintenance switch (this cannot be retrofitted), when service is required, the inverter can be simply disconnected from the line supply without having to have any additional components or additional wiring costs when configuring.

5/4

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Integration
The SINAMICS G110D distributed inverters have, as standard, the following interfaces: Motor connection via a HAN Q8 (connector) including control of the motor brake and temperature sensor Line supply connection via HAN Q4/2 (socket) Connection for a braking resistor in IP65 degree of protection through a three-pin connector AS-Interface connection via M12 (connector) Connection for four digital inputs via M12 (socket) Connection for an analog input via M12 (socket); this can also be used as digital input Connection for an AS-Interface addressing device via jack plug The interfaces are identical to those of the SINAMICS G120D distributed inverter and those of the SIRIUS M200D motor starter.

Jack socket for AS-Interface addressing device MMC SD

380 V to 500 V 3 AC L1 L2 L3 PE

HAN Q4/2 L1
X3.1 AS.i + X3.2 AUX 0 V

L2 2

L3 3

*) 4

*) 11

*) 12

PE PE

AS-Interface

AS-Interface connection

X3.3 ASi X3.4 AUX 24 V X3.5 Functional earth

Line filter class A 3~

X2.1 X2.2 X2.3 X2.4

X15.1 U10 V or U24 V

X15.3 AIN 0 V (U0 V) X15.4 AIN X15.5 Functional earth

Analog inputs

X15.2 AIN +

CPU
X7.1 U 24 V

Braking resistor = 3~

X3.2 D11 X3.4


24 V X3.3 D10

X7.3 U0 V X7.4 Digital Input 0 X7.5 Functional earth

Digital inputs

X7.2 Digital Input 1

Motor brake 1) Temperature sensor 1)

X8.1 U24 V

X4.2 D13 X4.4


24 V X4.3 D12

X8.4 Digital Input 2 X8.5 Functional earth

5 Optical interface HAN + Q8

8 -

4 -

6 +

PE

1 U

7 V

3 W

*) PE

M 3~ *) Not used.
1) Potential refers to DC link.

Manual-local control

Please consider this when selecting the motor cable

SINAMICS G110D connection diagram with integrated class A line filter

G_D011_DE_00196

X8.3 U0 V

Digital inputs

X8.2 Digital Input 3

Siemens D 11.1 2009

5/5

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Configuration
The following electronic configuring aids and engineering tools are available for the SINAMICS G110D distributed inverters: Selection guide, SD Configurator within the CA 01 More than 100.000 products with approximately 5 million possible product versions from the area of drive technology are listed in the Interactive Catalog CA 01 the Offline Mall from Siemens IA&DT. In order to make it easier to select the optimum motor and/or inverter from the wide range of Standard Drives, the SD Configurator was developed, which is integrated as Selection guide in this catalog on the DVD with the selection and configuration tools. Online SD Configurator In addition, the SD Configurator can now be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com STARTER commissioning tool The STARTER commissioning tool allows menu-prompted commissioning, optimization and diagnostics. In addition to SINAMICS drives, STARTER is also suitable for MICROMASTER 4 units and the drive converters for the distributed I/O SIMATIC ET 200S FC and SIMATIC ET 200pro FC. For SINAMICS G110D from STARTER Version 4.1.3 and higher. Drive ES engineering system Drive ES is the engineering system that can be used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. Therefor the STEP 7 Manager user interface forms the basis. Various software packages are available for SINAMICS: Drive ES Basic, Drive ES SIMATIC and Drive ES PCS 7.

Technical specifications

Unless explicitly specified otherwise, the following technical specifications are valid for all SINAMICS G110D distributed inverters.
General technical specifications

Mechanical specifications
Vibratory load according to EN 60068-2-6 Transport 1) Operation Shock according to EN 60068-2-27 Transport 1) Operation Degree of protection 5 9 Hz: Constant deflection, 3.1 mm 9 200 Hz: Constant acceleration = 9.81 m/s2 (1 g) 2 9 Hz: Constant deflection, 7 mm 9 200 Hz: Constant acceleration = 19.62 m/s2 (2 g) 147.15 m/s2 (15 g)/11 ms 3 Shocks in each axis and direction 147.15 m/s2 (15 g)/11 ms 3 Shocks in each axis and direction IP65 Class III (PELV) Class I (with protective conductor system) 95 % at 40 C 40 +70 C 40 +70 C 10 +40 C without derating > 40 55 C see derating characteristics Class 3C2 2 UL 508C (UL list number E121068), CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC Category C2 3) acc. to EN 61800-3 (corresponds to class A acc. to EN 55011)

Ambient conditions
Protection class acc. to EN 61800-5-1 Touch protection according to EN 61800-5-1 Max. humidity Ambient temperature Storage 1) acc. to EN 60068-2-1 Transport 1) acc. to EN 60068-2-1 Operation acc. to EN 60068-2-2 Environmental class/harmful chemical substances Operation acc. to EN 60721-3-3 Degree of pollution acc. to EN 61800-5-1

Standards
Compliance with standards CE mark EMC Directive 2) Frame sizes FSA to FSC with integrated class A line filter

Note: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive.

1) 2) 3)

In transport packaging. For further general information, see also SINAMICS G110 section Technical specifications, Compliance with standards. With shielded motor cables up to 15 m.

5/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Technical specifications
Technical specifications, control electronics

Electrical specifications
Operating voltage Current consumption, max. (from the non-switched 24 V supply, yellow AS-Interface cable) Current consumption, max. (from the switched 24 V supply, black AS-Interface cable) Without supplementary fan With supplementary fan Fixed frequencies
1)

external 24 V DC necessary 320 mA

180 mA 350 mA 6, parameterizable 4 1 AS-Interface Connection via Power Module 1 input, sensors that can be connected: PTC, KTY or Thermo-Click Connection via Power Modules Optional Connection with RS232 interface cable via the optical inverter interface Connection with USB interface cable via the optical inverter interface Signal interconnection with BICO technology Automatic restart after line supply failure or operational fault Slip compensation Free function blocks (FFB) for logic operations Ramp smoothing 3 selectable drive data sets 3 selectable command data sets (CDS) (manual/auto) Flying restart JOG Technology controller (PID) Thermal motor protection Thermal inverter protection Setpoint input Motor identification Motor holding brake

Interfaces
Digital inputs Analog inputs (0 ... 10 V) Bus interface PTC/KTY interface Motor temperature sensor Control of a mechanical motor brake MMC memory card slot RS232 interface USB interface

Open-loop/closed-loop control technique and software


V/f linear/square/parameterizable V/f with flux current control (FCC) Software functions

1)

Includes the current consumption of connected sensors. Analog input as voltage input, 0 V to 10 V.

Siemens D 11.1 2009

5/7

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Technical specifications
General technical specifications, power electronics System operating voltage Line supply requirements, line short circuit voltage uK Input frequency Output frequency Control type V/f Pulse frequency Power factor Inverter efficiency Modulation depth Overload capability High overload (HO) 380 ... 500 V 3 AC 10 % no restriction 47 ... 63 Hz 0 ... 650 Hz 4 kHz (Standard), higher pulse frequencies up to 16 kHz, see the derating data 0.7 ... 0.85 95 % 95 % Average maximum rated output current during a cycle time of 300 s 1.5 rated output current (i.e. 150 % overload) over 60 s at a cycle time of 300 s 2 rated output current (i.e. 200 % overload) over 3 s at a cycle time of 300 s Integrated class A line filter according to EN 55011 DC braking integrated brake control 180 V DC (corresponds to 400 V AC rectified) and 205 V DC (corresponds to 230 V AC rectified) Shutdown on the DC side permits fast braking. 600 mA (with UL approval) 1 A (without UL approval) Horizontal wall mounting and mounting in the horizontal position < 95 % RH, condensation not permissible FSA: Convection FSB and FSC: Air cooling as required using the integrated fan Up to 1000 m above sea level without power reduction > 1000 m see derating characteristics 10 kA Undervoltage Overvoltage Overcontrol/overload Ground fault Short circuit Stall protection Motor blocking protection Motor overtemperature Inverter overtemperature Parameter locking UL 508C (UL list number E121068), CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC

Electromagnetic compatibility

Possible braking methods

Output current, max. Permissible mounting position Relative humidity Cooling Installation altitude Standard Short Circuit Current Rating (SCCR) 1) Protection functions

Standards conformance CE mark

1)

Applies to industrial control cabinet installations to NEC Article 409/UL 508A. For further information, visit us on the Internet at: http://support.automation.siemens.com/WW/view/en/23995621

5/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Technical specifications
Line supply voltage 380 ... 500 V 3 AC Rated output current Irated 1) Rated pulse frequency Efficiency Rated power Rated input current 2) Line supply connection U1/L1, V1/L2, W1/L3, PE Conductor cross-section Motor connection U2, V2, W2, PE, motor brake, temperature sensor Conductor cross-section mm2 mm2 A SINAMICS G110D 6SL3511.PE17-5AM0 2.3 4.6 4 0.95 2.0 HAN Q4/2 (connector) 6SL3511.PE21-5AM0 4.3 8.6 4 0.95 1.5 (1.5) 3) 3.8 HAN Q4/2 (connector) 6SL3511.PE23-0AM0 7.7 15.4 4 0.95 3 (4.0) 7.0 HAN Q4/2 (connector) 6SL3511.PE24-0AM0 10.2 20.4 4 0.95 4 (5.4) 9.1 HAN Q4/2 (connector) 6SL3511.PE25-5AM0 13.2 26.4 4 0.95 5.5 (7.4) 12.2 HAN Q4/2 (connector) 6SL3511.PE27-5AM0 19 38 4 0.95 7.5 (10) 17.9 HAN Q4/2 (connector)

Output current Imax A kHz % A

kW (hp) 0.75 (1.0)

1.5 ... 6 HAN Q8 (socket)

1.5 ... 6 HAN Q8 (socket)

2.5 ... 6 HAN Q8 (socket)

2.5 ... 6 HAN Q8 (socket)

4 ... 6 HAN Q8 (socket)

4 ... 6 HAN Q8 (socket)

5
1 ... 4 15 IP65 1 ... 4 15 IP65 2.5 ... 4 15 IP65 2.5 ... 4 15 IP65 4 15 IP65 4 15 IP65

Motor cable length, m max. Degree of protection Dimensions Width Height Depth - Without maintenance switch mm mm mm

450 210 125 145 FSA

450 210 125 145 FSA 6.7 7.0

450 210 125 145 FSA 6.9 7.2

450 210 165 165 FSB 7.4 7.7

450 210 240 240 FSC 9.4 9.7

450 210 240 240 FSC 9.5 9.8

- With maintenance mm switch Frame size Weight, approx. Without maintenance switch with maintenance switch kg kg

6.7 7.0

1) 2)

The rated output current Irated is based on the duty cycle for high overload (HO). The input current depends on the motor load and line impedance. The input currents apply for load at rated power for a line impedance corresponding to uK = 1 %.

3)

It is not possible to make any assignment to a particular standard.

Siemens D 11.1 2009

5/9

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Characteristic curves
Derating data Pulse frequency
Rated power at 400 V 3 AC kW 0.75 1.5 3.0 4.0 5.5 7.5 hp 1.0 1.5 1) 4.0 5.0 7.5 10 Rated output current in A for a pulse frequency of 4 kHz 2.2 4.1 7.7 10.2 13.2 19 6 kHz 1.9 3.5 6.5 8.7 11.2 16.2 8 kHz 1.5 2.9 5.4 7.1 9.2 13.3 10 kHz 1.3 2.5 4.6 6.1 7.9 11.4 12 kHz 1.1 2.1 3.9 5.1 6.6 9.5 14 kHz 1.0 1.8 3.5 4.6 5.9 8.6 16 kHz 0.9 1.6 3.1 4.1 5.3 7.6

Ambient temperature
100 % 75
G_D011_EN_00124

Installation altitude
100 %
Permissible output current

Permissible output current

90
G_D011_EN_00203

55 50 25

84 80 75 70 60

-10

10

20

30

40

50 C 55 60

1000

Ambient temperature

2000 3000 m 4000 Installation altitude above sea level

100 %
Permissible input voltage

90 88
G_D011_EN_00204

80 78 70 60

1000

2000 3000 m 4000 Installation altitude above sea level

1)

It is not possible to make any assignment to a particular standard.

5/10

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Dimensional drawings
125 (4.92)

210 (8.27)

G_D011_EN_00197

Drill pattern

450 (17.72)

425 (16.73)

SINAMICS G110D, frame size FSA with integrated class A line filter

165 (6.5)

195 (7.68)

210 (8.27)

G_D011_EN_00198

Drill pattern

450 (17.72)

425 (16.73)

SINAMICS G110D, frame size FSB with integrated class A line filter

210 (8.27)

240 (9.45)

G_D011_EN_00199

Drill pattern

450 (17.72)

425 (16.73)

SINAMICS G110D, frame size FSC with integrated class A line filter

Mounted with 4 M5 studs, 4 M5 nuts, 4 M5 washers.

Ventilation clearance required (for wall mounting) at top and bottom: 150 mm (5.9 inches). All dimensions in mm (values in brackets are in inches).

195 (7.68)

195 (7.68)

Siemens D 11.1 2009

5/11

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G110D distributed inverters

Dimensional drawings
145 (5.71)

210 (8.27)

G_D011_EN_00200

Drill pattern

450 (17.72)

425 (16.73)

SINAMICS G110D, frame size FSA with integrated class A line filter and maintenance switch

210 (8.27)

165 (6.5)

G_D011_EN_00201

Drill pattern

450 (17.72)

425 (16.73)

SINAMICS G110D, frame size FSB with integrated class A line filter and maintenance switch

210 (8.27)

240 (9.45)

G_D011_EN_00202

Drill pattern

450 (17.72)

425 (16.73)

SINAMICS G110D, frame size FSC with integrated class A line filter and maintenance switch

Mounted with 4 M5 studs, 4 M5 nuts, 4 M5 washers.

Ventilation clearance required (for wall mounting) at top and bottom: 150 mm (5.9 inches). All dimensions in mm (values in brackets are in inches).

5/12

Siemens D 11.1 2009

195 (7.68)

195 (7.68)

195 (7.68)

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Recommended line components

Overview
The following table lists recommendations for additional lineside components, such as fuses and circuit breakers (line-side components dimensioned in accordance with IEC standards). The specified circuit breakers are UL-certified. 3NA3 fuses are recommended for European countries. The values in the table take into account the overload capability of the inverter. Additional information about the listed fuses and circuit breakers can be found in Catalogs LV 1 and LV 1 T.

Selection and ordering data


For individual protection
Rated power kW 0.75 1.5 3 4 5.5 7.5 hp 1 1.5 1) 4 5 7.5 10 SINAMICS G110D Type 6SL3511-... . PE17-5AM0 . PE21-5AM0 . PE23-0AM0 . PE24-0AM0 . PE25-5AM0 . PE27-5AM0 Frame size FSA FSA FSA FSB FSC FSC Protection A 10 10 26 20 20 32 Fuse Order No. 3NA3803 3NA3803 3NA3805 3NA3807 3NA3807 3NA3812 Circuit breaker Order No. 3RV1021-1FA10 3RV1021-1JA10 3RV1021-4AA10 3RV1021-4BA10 3RV1031-4EA10 3RV1031-4FA10

380 ... 500 V 3 AC

Group protection The group protection designates those configurations in which a circuit-breaker or a fuse provides protection for two or several devices and their feeder cables. The protective device is known as branch protection (BCP) device. You will find additional information on the group protection and recommended types in the FAQ: http://support.automation.siemens.com/ww/view/en/31560253

1)

It is not possible to make any assignment to a particular standard.

Siemens D 11.1 2009

5/13

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
DC link components

Overview
Braking Resistors Excess energy in the DC link is dissipated in the braking resistor. The braking resistors are intended for use with SINAMICS G110D, which have an integrated brake chopper, but cannot feed back generated energy to the line supply. For generator mode, e.g. braking a rotating mass with high moment of inertia, a braking resistor must be connected to convert the energy into heat. The braking resistors can be mounted above and to the side of the SINAMICS G110D distributed inverter. The heat dissipated by the braking resistor must not diminish the inverter cooling. This is the reason that a minimum clearance of 150 mm must be maintained between the inverter and braking resistor. Every braking resistor has thermal protection (UL-listed). The thermal protection prevents the braking resistor from being thermally overloaded. All of the braking resistors are provided as standard with a cable; this is pre-fabricated and is 500 mm long.

Selection and ordering data


Rated power Suitable for SINAMICS G110D Type 6SL3511-... . PE17-5AM0 . PE21-5AM0 . PE23-0AM0 . PE24-0AM0 . PE25-5AM0 . PE27-5AM0 Braking resistor

kW 0.75 1.5 3.0 4.0 5.5 7.5

hp 1 1.5 1) 10 4 10 15

Frame size Order No. FSA FSA FSA FSB FSC FSC
new new new

380 ... 500 V 3 AC


6SL3501-0BE08-6AA0 6SL3501-0BE12-1AA0 6SL3501-0BE14-1AA0

Technical specifications
Line supply voltage 380 ... 500 V 3 AC Resistor Rated power PDB Peak power Pmax (cycle time 12 s) Degree of protection Dimensions Width Height Depth Weight, approx. Suitable for SINAMICS G110D Frame size mm mm mm kg Type 290 150 2) 140 2.5 6SL3511-.PE17-5AM0 6SL3511-.PE21-5AM0 FSA 340 150 2) 140 2.9 6SL3511-.PE23-0AM0 6SL3511-.PE24-0AM0 FSA/FSB 530 150 2) 140 4.3 6SL3511-.PE25-5AM0 6SL3511-.PE27-5AM0 FSC kW kW Braking resistor 6SL3501-0BE08-6AA0 390 0.086 1.725 IP65 6SL3501-0BE12-1AA0 160 0.21 4.2 IP65 6SL3501-0BE14-1AA0 82 0.41 8.2 IP65

1)

It is not possible to make any assignment to a particular standard.

2)

For the specified height (150 mm) the required bending radius of the braking resistor connecting cable to the SINAMICS G110D has not been taken into account.

5/14

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Intelligent Operator Panel IOP Handheld Updating the IOP Handheld The IOP Handheld can be updated and expanded using the integrated USB interface. Data to support future drive systems can be transferred from the PC to the IOP Handheld via drag & drop. Further, the USB interface allows user languages and Wizards that become available in the future to be subsequently downloaded and the firmware updated for the IOP Handheld. The IOP is supplied with power via the USB interface during an update. Selection and ordering data
Designation IOP Handheld For use with SINAMICS G120, SINAMICS G110D, SINAMICS G120D, SIMATIC ET 200S FC or SIMATIC ET 200pro FC Included in the scope of delivery: IOP Handheld housing Rechargeable batteries (4 AA) Charging unit (international) RS232 connecting cable (3 m long, can only be used for SINAMICS G120 and SIMATIC ET 200S FC) USB cable (1 m long) RS232 interface cable With optical interface to connect the SINAMICS G110D, SINAMICS G120D or SIMATIC ET 200pro FC inverters to the IOP Handheld (2.5 m long)
new

Order No. 6SL3255-0AA00-4HA0

IOP Handheld for mobile use

The Intelligent Operator Panel IOP Handheld is a very userfriendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of the SINAMICS G110D distributed inverter. The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, the menu prompting and the Application Wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list as the parameters are displayed in plain text, explanatory help texts are provided and the parameter filtering function. Application Wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors. There are Quick Commissioning Wizards for general commissioning. The drives are manually and simply controlled using directly assigned buttons and the navigation wheel. The IOP Handheld has a dedicated switchover key to switch over from the automatic to the manual mode. The inverter can be diagnosed in a user-friendly fashion using the plain text display of faults and alarms. Help texts can be obtained by pressing the INFO button. Up to two process values can either be graphically or numerically visualized on the status screen/status display. Process values can also be displayed in technological units. The IOP Handheld supports series commissioning of identical drives. For this purpose, a parameter list can be copied from an inverter into the IOP Handheld and when required, downloaded into other drive units of the same type. The IOP Handheld includes the following language packages: English, French, German, Italian and Spanish. In addition to the IOP, the IOP Handheld includes a housing with the rechargeable batteries, charging unit and RS232 interface cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 8 hours. To connect the IOP Handheld to SINAMICS G110D, the RS232 interface cable with optical interface is required in addition.

3RK1922-2BP00

Siemens D 11.1 2009

5/15

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Manual-local control with keyswitch MMC memory card

Example: SINAMICS G110D and manual-local control with integrated keyswitch

The manual-local control is a simple method to locally control and commission the SINAMICS G110D distributed inverter. To switch over from the automatic to the manual mode or to switch-off the inverter, there is a keyswitch that can be withdrawn in each of the three operating modes (Auto/Off/Local). The inverter is controlled via the PLC in the automatic mode In the OFF state, the device is shut down (however, the line supply voltage is still connected) The drive is locally and directly controlled in the Local setting. The device is simply controlled using directly assigned buttons. The following functions can be selected: - Switching over between continuous operation / jog mode - On/Counter-clockwise - On/Clockwise - Deactivate Quick Stop The manual-local control is mounted on the inverter instead of the standard blanking cover. This means that it can be retrofitted at a later date. Selection and ordering data
Designation Manual-local control with keyswitch
new

The parameter settings for an inverter can be stored on the MMC memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again. The card holder is not included with the inverter and must be separately ordered. Selection and ordering data
Order No. MMC memory card 6SL3254-0AM00-0AA0

Order No. 6SL3555-0PL00-2AA0

5/16

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Card holder for MMC/SD memory card RS232 interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC via a point-to-point connection if the appropriate software (STARTER commissioning tool1), from Version 4.1.3 and higher) has been installed. Selection and ordering data
Order No. RS232 interface cable for communication with a PC 3RK1922-2BP00

USB interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC via a point-to-point connection if the appropriate software (STARTER commissioning tool 1), from Version 4.1.3 and higher) has been installed. Selection and ordering data
Order No.

To use the MMC memory card, a card holder is required. This can be subsequently inserted under the blanking cover or under the optional manual-local control on the inverter where it can also remain. In addition, a Secure Digital card (SD) can also be used.

USB interface cable for communication with a PC (2.5 m long)

new

6SL3555-0PA00-2AA0

Adapter to mount SINAMICS G110D instead of SIRIUS M200D motor starter For adaptation, there are connection boards that allow SINAMICS G110D to be mounted onto existing connection holes of the SIRIUS M200D motor starter (assuming that there is sufficient space). This means that a system can be correspondingly adapted to different requirements at a later stage. Selection and ordering data
Order No. Adapter to mount SINAMICS G110D instead of SIRIUS M200D motor starter
new

6SL3263-1GA20-0GA0

STARTER commissioning tool The STARTER commissioning tool (STARTER Version from 4.1.3 and higher) supports the commissioning and maintenance of SINAMICS G110D inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.
SINAMICS G110D with integrated card holder (in the open state)

Selection and ordering data


Order No. STARTER commissioning tool 1) on DVD 6SL3072-0AA00-0AG0

Selection and ordering data


Order No. Card holder for MMC/SD memory card
new

6SL3555-0PM00-0AA0

1)

The STARTER commissioning tool is also available on the Internet under http://support.automation.siemens.com/WW/view/en/10804985/133100

Siemens D 11.1 2009

5/17

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
AS-Interface connecting cables Selection and ordering data
Order No. AS-Interface M12 branch To connect the AS-Interface and VAux cable to an M12 socket Length: 1.0 m 2.0 m
new new

3RK1901-1NR21 3RK1901-1NR22

Connecting cables for digital inputs Selection and ordering data


Order No. M12 plug-in cables With PUR sheath, to connect digital sensors and actuators, pre-fabricated at one end, angled, plug connector, 5-pole, 5 0.34 mm2 length:

1.5 m 5m 10 m

new new new

3RX8000-1CE52-1AB5 3RX8000-1CE52-1AF0 3RX8000-1CE52-1AL0

Connecting cables pre-fabricated at one end and connector sets to connect to the line supply Selection and ordering data
Order No. Connecting cable pre-fabricated at one end Power supply cable, open at one end, for HAN Q4/2, angled, 4 4 mm2 1.5 m long 5 m long Connector set for the power supply HAN Q4/2 2.5 mm2 4 mm2 6 mm2 3RK1911-2BE50 3RK1911-2BE10 3RK1911-2BE30 3RK1911-0DB13 3RK1911-0DB33

5/18

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Motor cables pre-fabricated at one end and connector sets to connect the inverter to the motor Selection and ordering data
Motor cables preOrder No. fabricated at one end (HTG: supplied from the Harting Company) For motors with brake (ZKT: supplied from the KnorrTec Company) and temperature sensor with HAN Q8 connector, shielded Cross-section 1.5 m long
new

1 mm2 ZKT: 70018601000150

1.5 mm2 HTG: 61 88 201 0288


new

2.5 mm2 HTG: 61 88 201 0291 ZKT: 70009601000150 HTG: 61 88 201 0292
new new

4 mm2 HTG: 61 88 201 0303 ZKT: 70017001000150 HTG: 61 88 201 0304


new

3 m long
new

HTG: 61 88 201 0289 ZKT: 70018601000300 HTG: 61 88 201 0290


new

ZKT: 70009601000300 HTG: 61 88 201 0293 ZKT: 70009601000500 HTG: 61 88 201 0301 ZKT: 70009601001000

ZKT: 70017001000300 HTG: 61 88 201 0305 ZKT: 70017001000500 HTG: 61 88 201 0306 ZKT: 70017001001000

5 m long ZKT: 70018601000500 10 m long


new

new

new

HTG: 61 88 201 0299 ZKT: 70018601001000


new

new

Connector set for motor cables Shielded, HAN Q8 up to 1.5 mm


2

Order No.

5
6ES7194-1AB01-0XA0

Connector set for motor cables Shielded, HAN Q8 up to 2.5 mm2 up to 4 mm2

Order No. (HTG: supplied from the Harting Company) (ZKT: supplied from the KnorrTec Company)
new new

HTG: 61 83 401 0132 ZKT: 10032011


new new

HTG: 61 83 401 0133 ZKT: 10032021

Power bus distribution 400 V in IP65 degree of protection


Ordering (see Solution Partner) Power T clamp connector for 2.5 ... 6 mm2 With attached 7-pole connector, socket insert, grommet housing, UL Seals for various cable cross-sections must be separately ordered T clamp connector Completely pre-fabricated T distributor box, IDC connection, power cable Uncut power cable, 2.5 ... 6 mm2, 2 outgoing feeders: Push-in connection: 1.5 ... 6 mm2 Seals for various cable cross-sections must be separately ordered T distributor box Completely pre-fabricated Ordered and supplied from the Harting Company

Additional information For further information about the connecting cables and plug-in connectors mentioned above, please refer to Catalog IK PI. Further selected accessories are available from Siemens Solution Partners. Select Distributed Field Installation System as technology in the SolutionPartner Finder. http://www.siemens.com/ automation/partnerfinder

Ordered and supplied from the KnorrTec Company Ordered and supplied from the Weidmller Company

Ordered and supplied from the KnorrTec Company

Siemens D 11.1 2009

5/19

Siemens AG 2009

SINAMICS G110D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Spare parts Spare Parts Kit Spare parts Replacement fan

Overview
A Spare Parts Kit can be ordered which comprises small parts such as replacement seals, caps and screws.

Overview
The fans are designed for an extra long service life. Replacement fans can be ordered for special applications.

Selection and ordering data


Order No. Spare Parts Kit for SINAMICS G110D Comprising replacement seals, caps and screws
new

Selection and ordering data


Rated power kW 4 5.5 7.5 hp 5 7.5 10 SINAMICS G110D Type 6SL3511-... . PE24-0AM0 . PE25-5AM0 . PE27-5AM0 Replacement fan 6SL3500-0TK01-0AA0 Frame size Order No. FSB FSC
new

380 500 V 3 AC
6SL3500-0TF01-0AA0 (pre-mounted unit with cover, fan and screws)

5/20

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)


6/2 6/2 6/3 6/4 6/4 6/5 6/6 6/7 6/7 6/7 6/8 6/9 6/11 6/13 6/13 6/13 6/14 6/15 6/18 6/19 6/20 6/20 6/20 6/21 6/21 6/22 6/22 6/22 6/22 6/23 6/23 6/23 6/23 6/24

SINAMICS G120D distributed inverters Overview Benefits Applications Design Configuration Technical specifications CU240D Control Units Overview Selection and ordering data Design Integration Technical specifications PM250D Power Modules Overview Selection and ordering data Integration Technical specifications Characteristic curves Dimensional drawings Recommended line components Overview Selection and ordering data Supplementary system components Intelligent Operator Panel IOP Handheld MMC memory card RS232 interface cable for communication with a PC USB interface cable for communication with a PC STARTER commissioning tool PROFINET connecting cable PROFIBUS connecting cable Connecting cables/connectors for supplying the Control Unit with power Connecting cables for digital inputs Connecting cables pre-fabricated at one end and connector sets to connect to the line supply Motor cables pre-fabricated at one end and connector sets to connect the Power Module to the motor Power bus distribution 400 V in IP65 degree of protection Additional information Spare parts Spare Parts Kit Replacement fan

6/24

6/25 6/25 6/26 6/26 6/26

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G120D distributed inverters

Overview
The new SINAMICS G120D distributed frequency inverter series is the solution for demanding drive tasks especially in the field of conveyor systems. SINAMICS G120D inverters continuously control the speed of three-phase asynchronous motors and fulfill all the requirements of conveyor system applications from simple frequency control through to demanding vector control. With its well-thought-out modular design with IP65 degree of protection, it can be seamlessly integrated into the plant or system and supports a high plant availability and low stocks of spare parts. The innovative power unit concept capable of energy recovery helps to save energy. Safety functions that are unique worldwide permit improved plant and system concepts with a higher productivity. This drive can be optimally integrated into the Siemens TIA world of automation via PROFIBUS or PROFINET. With different device versions (frame sizes FSA to FSC) in a power range from 0.75 kW to 7.5 kW (1.0 hp to 10 hp), it is suitable for a wide variety of drive solutions. Siemens family of distributed drives Siemens offers an innovative portfolio of frequency inverters to optimally implement distributed drive solutions. The strengths of the individual members of the drive family permit simple adaptation to the widest range of application demands: Identical connection systems Identical mounting dimensions for SINAMICS G110D and SINAMICS G120D Standard commissioning and configuration tool Products from the family of distributed drives: SINAMICS G110D frequency inverters SINAMICS G120D frequency inverters SIMATIC ET 200S FC drive converters SIMATIC ET 200pro FC drive converters SIRIUS M200D motor starters Modularity SINAMICS G120D is a modular inverter system with IP65 degree of protection comprising various function units. The main units are: Control Unit (CU) Power Module (PM)

The Control Unit controls and monitors the Power Module and the connected motor using several different closed-loop control types that can be selected. The digital inputs and digital outputs on the device support the simple wiring of sensors and actuators directly at the drive. The input signals can either be directly linked within the Control Unit and initiate local responses independently or they can be transferred to the central control via PROFIBUS or PROFINET for processing within the context of the overall plant.
Example: SINAMICS G120D, frame size FSA, comprising PM250D Power Module and Fail-safe CU240D DP-F Control Unit

Reasons for using distributed drive systems Modular drive solutions therefore standardized mechatronic elements that can be individually tested A control cabinet is not required, resulting in a smaller space requirement and lower cooling requirements Long cables between the inverter and motor can be avoided (which means lower power losses, reduced noise emission and lower costs for shielded cables and additional filters) Distributed configurations offer considerable benefits for conveyor systems with their extensive coverage (e.g. in the automotive and logistics sectors)

The Power Module supplies the motor in a power range 0.75 kW to 7.5 kW (1.0 hp to 10 hp). The Power Module is controlled by a microprocessor in the Control Unit. State-of-the-art IGBT technology with pulse-width-modulation is used for highly reliable and flexible motor operation. Comprehensive protection functions provide a high degree of protection for the Power Module and the motor. The unusually low profile mechanical design is optimized so that the device can be directly used in the plant or system. The Power Module also has the same drilling dimensions for all power ratings (one standard footprint). Further, the dimensions are identical to those of SINAMICS G110D. This significantly simplifies the mechanical design, installation and retrofit of a system. The latest technical documentation (catalogs, dimensional drawings, certificates, manuals and operating instructions), are available on the Internet under: http://www.siemens.com/sinamics-g120d/documentation and offline on the DVD CA 01 in the SD Configurator. In addition, the SD Configurator can be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com/dt-configurator

6/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G120D distributed inverters

Overview
Safety Integrated The SINAMICS G120D distributed inverters include versions for safety-oriented applications. All Power Modules are already designed for Safety Integrated. A Safety Integrated Drive can be created by combining a Power Module with the relevant Fail-safe Control Unit. SINAMICS G120D fail-safe inverter provides three safety functions, certified in accordance with EN 954-1, Category 3 and IEC 61508 SIL 2: Safe Torque Off (STO) to protect against active movement of the drive Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp Safely Limited Speed (SLS) for protection against dangerous movements when a speed limit is exceeded The functions Safe Stop 1 and Safely Limited Speed can both be implemented without having to use a motor encoder or encoder; the implementation cost is minimal. Existing systems in particular can be updated with safety technology without the need to change the motor or mechanical system. The safety functions Safely Limited Speed and Safe Stop 1 are not certified for pull-through loads such as e.g. hoisting gear and unwinders. Additional information is provided in the part Highlights, section Safety Integrated. Efficient Infeed Technology The advanced Efficient Infeed Technology is employed in PM250D Power Modules. This technology allows the energy produced by motors operating in generator mode connected to standard inverters to be fed back into the supply system. At the same time, considerable savings can be achieved in terms of energy consumption and operating costs. Additional information is included in the part Highlights, section Efficient Infeed Technology. STARTER commissioning tool The STARTER commissioning tool (from STARTER Version 4.1, SP1 and higher) supports the commissioning and maintenance of SINAMICS G120D inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily.

7 7

7 7

7 7 7

7 7 7

Benefits
7

7 7 7

Mechanical design, installation and retrofit of a system are significantly simplified as a result of the compact and spacesaving design with an extremely low profile and with the same drilling dimensions for all power ratings; further, the dimensions are identical with those of the SINAMICS G110D Wide power range from 0.75 kW to 7.5 kW (1.0 hp to 10 hp) The safety functions make it easier to integrate drives into safety-oriented machines or plants The innovative circuit design (bidirectional input rectifier with pared-down DC link) allows the kinetic energy of a load to be fed back into the line supply system. This feedback capability provides enormous potential for energy savings because generated energy no longer has to be converted into heat in a braking resistor. Braking resistors and reactors are not necessary this is a particular advantage in terms of the space requirement and installation costs for the high IP65 degree of protection Simple commissioning and maintenance as a result of the same, standard plug-in connections of the bus, power and I/O connections (ISO 23570) for the complete range of power ratings of SINAMICS G110D and SINAMICS G120D

Increased degree of ruggedness and longer service life as the electronic modules are coated Flexibility due to modularity for a future-oriented distributed drive concept with a high IP65 degree of protection - Module replacement under voltage (hot swapping) - The modules can be easily replaced, which makes the system extremely service friendly Simple, standard implementation of completely distributed plant and system concepts by using products in a scalable fashion: - SIRIUS M200D (motor starter) - SINAMICS G110D (inverter for basic, conveyor-related applications) - SINAMICS G120D (inverter for sophisticated, conveyorrelated applications) The same connectors are used as for the SIRIUS M200D motor starter Communications-capable via PROFINET or PROFIBUS with PROFIdrive Profile 4.0 - Reduced number of interfaces - Plantwide engineering - Easy to handle Simple connection, configuration, data management as well as control of the inverter in complex plants and systems as a result of the consequential integration in TIA (Totally Integrated Automation) High degree of operator friendliness by using the Intelligent Operator Panel (IOP) to parameterize, diagnose, control (open-loop) and copy drive parameters in the IOP The ability to connect up to six sensors and two actuators directly to the Control Unit means that almost all of the drive information can be directly managed; local preprocessing of the signals takes the load off the fieldbus and ensures a fast and reproducible response time Integrated class A EMC filter (acc. to EN 55011) Integrated brake control, brake voltages that are supported, 400 V AC / 180 V DC Integrated motor protection using a thermal motor model and evaluation of PTC, Thermo-Click or KTY 84 temperature sensors Software parameters for simple adaptation to 50 Hz or 60 Hz motors (IEC or NEMA motors) Easy replacement of devices and fast copying of parameters to the memory card using the optional MMC memory card Engineering and commissioning with standard engineering tools such as SIZER (from Version 2.9 and higher), STARTER (from Version 4.1, SP1 and higher) and Drive ES: Ensure fast engineering and easy commissioning STARTER is integrated in STEP 7 with Drive ES Basic with all the advantages of central data storage and totally integrated communication Certified worldwide for compliance with CE, UL, cUL, C-tick and Safety Integrated according to EN 954-1, Category 3 and IEC 61508 SIL 2

Siemens D 11.1 2009

6/3

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G120D distributed inverters

Applications
SINAMICS G120D is ideally suited to demanding conveyor system applications in the industrial environment for which a distributed drive with communications capability is required. This applies in particular to the automotive sector, e.g. assembly lines. SINAMICS G120D is also suitable for additional high-performance applications, e.g. in the airport sector, food and beverage industry (without tenside) and in distribution logistics (e.g. electric monorail systems).

Control Units The following Control Units are available for SINAMICS G120D distributed inverters: CU240D Control Units The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. Several Control Units are available in different versions: CU240D DP CU240D DP-F CU240D PN CU240D PN-F Supplementary System Components Intelligent Operator Panel IOP Handheld
Power Module Control Unit

Design
The SINAMICS G120D distributed frequency inverters are modular inverters for standard drives. Each SINAMICS G120D comprises two operative units the Power Module and Control Unit.

The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, the menu prompting and the Application Wizards, it is easy to commission, diagnose and locally control standard drives. MMC memory card The parameter settings for an inverter can be stored on the MMC memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again. The associated slot is located on the rear of the Control Unit. RS232 interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool from Version 4.1, SP1 and higher) has been installed. USB interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC if the appropriate software (STARTER commissioning tool from Version 4.1.3 and higher) has been installed. Connecting cable for the Control Units Flexible plug-in cables to transfer data between the Industrial Ethernet participants or PROFIBUS participants, as well as to supply power to the Control Unit. Connecting cable for the Power Modules Connector sets to connect to the line supply and the outgoing motor feeder are available as accessories as well as pre-fabricated motor cables for connection to the motor. Spare Parts Kit A Spare Parts Kit is available which comprises small parts such as seals, caps, PROFIBUS address windows and screws. Replacement fan A replacement fan is available, which comprises a pre-mounted unit with cover, fan and screws.

Line supply connection Motor connection

Power Module PM250D with line and motor connections and CU240D Control Unit

Power Modules The following Power Modules are available for the SINAMICS G120D distributed inverters: PM250D Power Modules PM250D Power Modules (0.75 kW to 7.5 kW/1.0 hp to 10 hp) have an innovative circuit design which allows line-commutated energy recovery back into the line supply. This innovative circuit permits generated energy to be fed back into the supply system and therefore saves energy.

6/4

Siemens D 11.1 2009

G_D011_EN_00126

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G120D distributed inverters

Configuration
The following electronic configuring aids and engineering tools are available for the SINAMICS G120D distributed inverters: Selection guide, SD Configurator within the CA 01 More than 100,000 products with approximately 5 million possible product versions from the area of drive technology are listed in the Interactive Catalog CA 01 the Offline Mall from Siemens IA&DT. In order to make it easier to select the optimum motor and/or inverter from the wide range of Standard Drives, the SD Configurator was developed, which is integrated as Selection guide in this catalog on the DVD with the selection and configuration tools. Online SD Configurator In addition, the SD Configurator can now be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com/dt-configurator SIZER Configuration Tool The SIZER PC tool makes it easy to engineer the SINAMICS and MICROMASTER 4 drive family. It provides support when selecting the hardware and firmware components necessary to implement a drive task. SIZER supports the configuration of the complete drive system and allows simple single-motor drives up to complex multi-axis applications to be engineered. For SINAMICS G120D from SIZER Version 2.9 and higher. STARTER Commissioning Tool The STARTER commissioning tool allows menu-prompted commissioning, optimization and diagnostics. In addition to SINAMICS drives, STARTER is also suitable for MICROMASTER 4 units and the drive converters for the distributed I/O SIMATIC ET 200S FC and SIMATIC ET 200pro FC. For SINAMICS G120D from STARTER Version 4.1, SP1 and higher. Drive ES Engineering System Drive ES is the engineering system used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. The STEP 7 Manager user interface forms the basis. A variety of software packages, i.e. Drive ES Basic, Drive ES SIMATIC and Drive ES PCS 7, are available for SINAMICS.

Siemens D 11.1 2009

6/5

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
SINAMICS G120D distributed inverters

Technical specifications
Unless explicitly specified otherwise, the following technical specifications are valid for all the following components of the SINAMICS G120D distributed inverter listed here.
SINAMICS G120D

Mechanical specifications
Vibratory load according to EN 60068-2-6 Transport Operation Shock load according to EN 60068-2-27 Transport Operation
1) 1)

5 9 Hz: Constant deflection, 3.1 mm 9 200 Hz: Constant acceleration = 9.81 m/s2 (1 g) 10 58 Hz: Constant deflection, 0.15 mm 58 200 Hz: Constant acceleration = 19.62 m/s2 (2 g) 147.15 m/s2 (15 g)/11 ms 3 Shocks in each axis and direction 147.15 m/s2 (15 g)/11 ms 3 Shocks in each axis and direction Class III (PELV) Class I (with protective conductor system) 10 +40 C without derating > 40 55 C see derating characteristics CU240D DP: 10 +55 C CU240D PN: 10 +50 C CU240D DP-F: 0 55 C CU240D PN-F: 0 50 C (> 40 ... 55 C see derating characteristics) up to 2000 m above sea level Temperature 40 +70 C Temperature 40 +70 C max. humidity 95 % at 40 C Temperature 10 +40 C without derating Class 3C2 2 3 2 Available soon 5 108 10 Years UL 508C (UL list number E121068), CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC Category C2 3) acc. to EN 61800-3 (corresponds to class A acc. to EN 55011)

Ambient conditions
Protection class acc. to EN 61800-5-1 Touch protection according to EN 61800-5-1 Permissible ambient and coolant temperature (air) during operation for Power Modules Permissible ambient and coolant temperature (air) during operation for Control Units

Climatic ambient conditions Storage 1) acc. to EN 60068-2-1 Transport 1) acc. to EN 60068-2-1 Operation acc. to EN 60068-2-2 Environmental class/harmful chemical substances Operation acc. to EN 60721-3-3 Degree of pollution acc. to EN 61800-5-1

Certification for Fail-safe versions


Category acc. to EN 954-1 SIL Cl acc. to IEC 61508 PL acc. to ISO 13849 PFHD T1

Standards
Compliance with standards CE mark EMC Directive 2) Frame sizes FSA to FSC with integrated class A line filter Note: The EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter. The frequency inverters on their own do not generally require identification according to the EMC Directive.

1) 2)

In transport packaging. For further general information, see also SINAMICS G110 section Technical specifications, Compliance with standards.

3)

With shielded motor cable up to 15 m.

6/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
CU240D Control Units

Overview
The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. Control Units are available in different versions: CU240D DP CU240D DP-F CU240D PN CU240D PN-F Safety Integrated functions The SINAMICS G120D fail-safe inverter provides three safety functions, certified in accordance with EN 954-1, Category 3 and IEC 61508 SIL 2: Safe Torque Off (STO) to protect against active movement of the drive Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp Safely Limited Speed (SLS) for protection against dangerous movements when a speed limit is exceeded The functions Safe Stop 1 and Safely Limited Speed can both be implemented without a motor encoder or encoder; the implementation cost is minimal. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system. The safety functions Safely Limited Speed and Safe Stop 1 are not permitted for pull-through loads such as e.g. hoisting gear and unwinders. Safety functions have been extended with firmware V3.2. Additional information is provided in the part Highlights, section Safety Integrated.

Example of CU240D DP-F Control Unit

Example of CU240D PN-F Control Unit

Selection and ordering data


Communication Digital inputs Digital outputs Encoder interfaces Designation Control Unit Order No. 6SL3544-0FA20-1PA0 6SL3544-0FA20-1FA0 6SL3544-0FA21-1PA0 6SL3544-0FA21-1FA0

Standard
PROFIBUS DP PROFINET PROFIBUS DP PROFINET 6 6 6 6 2 2 2 2 1 1 1 1 CU240D DP CU240D PN CU240D DP-F CU240D PN-F

Fail-safe for Safety Integrated

Siemens D 11.1 2009

6/7

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
CU240D Control Units

Design
Optical interface for PC connection LEDs 24 V supply PROFIBUS ADDRESS Dip switch
(1) Bit 0 (2) Bit 1 (4) Bit 2 (8) (16) (32) (64) ON Bit 3 Bit 4 Bit 5 Bit 6

Optical interface for PC connection LEDs

24 V supply
1

Digital outputs PROFIBUS bus termination OFF ON Encoder interface PROFINET interface

Encoder interface Digital outputs PROFIBUS interface Digital inputs

Digital inputs

G_D011_EN_00165

G_D011_EN_00167

CU240D DP Control Unit


Optical interface for PC connection LEDs

CU240D PN Control Unit


Optical interface for PC connection LEDs
SF RDY BF ES STO SS1 SLS

24 V supply PROFIBUS ADDRESS Dip switch


(1) (2) (4) (8) (16) (32) (64) ON
X01 DC24V X02 DC24V

24 V supply
1
X03 P1 ACT LNK X03 P2 ACT LNK DO0 DO1

Digital outputs

PROFIBUS bus termination OFF ON

Encoder interface Digital outputs PROFIBUS interface


DI0 DI1 DI2 DI3 DI4 DI5

Encoder interface PROFINET interface

Digital inputs

Digital inputs

G_D011_EN_00166

G_D011_EN_00168

CU240D DP-F Control Unit

CU240D PN-F Control Unit

Control Unit, view from the rear, MMC slot at the top and PM-IF interface at bottom center

6/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
CU240D Control Units

Integration
MMC

PROFIBUS ADDRESS DIP switch X1.1 Switched 0 V (2M) X1.2 Unswitched 0 V (1M) X1.3 Functional earth X1.4 Unswitched +24 V (1L+) X1.5 Switched +24 V (2L+) X2.1 Switched 0 V (2M) X2.2 Unswitched 0 V (1M) X2.3 Functional earth X2.4 Unswitched +24 V (1L+) X2.5 Switched +24 V (2L+) X3.1 *) X3.2 Data A (N) X3.3 *) X3.4 Data B (P) X3.5 Functional earth X4.1 *) X4.2 Data A (N) X4.3 *) X4.4 Data B (P) X4.5 Functional earth 24 V, 500 mA max. X5.1 *) X5.2 Digital output 1 X5.3 Switched 0 V (2M) X5.4 Digital output 0 X5.5 Functional earth 24 V, 500 mA max. X6.1 Channel A X6.2 Channel A' X6.3 Channel B X6.4 Channel B' X6.5 Channel Z X6.6 Channel Z' X6.7 Unswitched +24 V (1L+) X6.8 Unswitched 0 V (1M) X7.2 X7.4 24 V X7.3 X8.2 X8.4 24 V X8.3 DI3 DI2 DI1 DI0 X7.1 Unswitched 24 V (1L+) X7.2 Digital input 1 X7.3 Unswitched 0 V (1M) X7.4 Digital input 0 X7.5 Functional earth X8.1 Unswitched 24 V (1L+) X8.2 Digital input 3 X8.3 Unswitched 0 V (1M) X8.4 Digital input 2 X8.5 Functional earth X9.1 Unswitched 24 V (1L+) X9.2 *) X9.3 Unswitched 0 V (1M) X9.4 Digital input 4 X9.5 Functional earth X10.1 Unswitched 24 V (1L+) X10.2 *) X10.3 Unswitched 0 V (1M) X10.4 Digital input 5 X10.5 Functional earth *) Not connected ON OUT IN Voltage supply 24 V
(1) Bit 0 (2) Bit 1 (4) Bit 2 (8) (16) (32) (64) Bit 3 Bit 4 Bit 5 Bit 6

OFF

Bus termination PROFIBUS OFF ON

OUT IN PROFIBUS DP interface

Optical interface

Digital outputs

6
Control Units CU240D DP CU240D DP-F

Encoder interface

PM-IF interface

Power module

X9.4 24 V X9.3 DI4

Digital inputs

X10.4 24 V X10.3 DI5

Connection diagram for CU240D DP and CU240D DP-F Control Units

G_D011_EN_00208

Siemens D 11.1 2009

6/9

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
CU240D Control Units

Integration
MMC

X2.1 Switched 0 V (2M) X2.2 Unswitched 0 V (1M) X2.3 Functional earth X2.4 Unswitched +24 V (1L+) X2.5 Switched +24 V (2L+)

OUT IN PROFINET interface

X3.1 Transmission data + X3.2 Reception data + X3.3 Transmission data X3.4 Reception data X4.1 Transmission data + X4.2 Reception data + X4.3 Transmission data X4.4 Reception data

OUT IN Voltage supply 24 V

X1.1 Switched 0 V (2M) X1.2 Unswitched 0 V (1M) X1.3 Functional earth X1.4 Unswitched +24 V (1L+) X1.5 Switched +24 V (2L+)

Optical interface

X5.1 *) X5.2 Digital output 1 X5.3 Switched 0 V (2M) X5.4 Digital output 0 X5.5 Functional earth 24 V, 500 mA max. X6.1 Channel A X6.2 Channel A' X6.3 Channel B X6.4 Channel B' X6.5 Channel Z X6.6 Channel Z' X6.7 Unswitched +24 V (1L+) X6.8 Unswitched 0 V (1M) X7.2 X7.4 24 V X7.3 X8.2 X8.4 24 V X8.3 DI3 DI2 DI1 DI0 X7.1 Unswitched 24 V (1L+) X7.2 Digital input 1 X7.3 Unswitched 0 V (1M) X7.4 Digital input 0 X7.5 Functional earth X8.1 Unswitched 24 V (1L+) X8.2 Digital input 3 X8.3 Unswitched 0 V (1M) X8.4 Digital input 2 X8.5 Functional earth X9.1 Unswitched 24 V (1L+) X9.2 *) X9.3 Unswitched 0 V (1M) X9.4 Digital input 4 X9.5 Functional earth X10.1 Unswitched 24 V (1L+) X10.2 *) X10.3 Unswitched 0 V (1M) X10.4 Digital input 5 X10.5 Functional earth

Digital outputs

24 V, 500 mA max.

Control Unit CU240D PN CU240D PN-F

Encoder interface

PM-IF interface

Power module

X9.4 24 V X9.3 DI4

Digital inputs

X10.4 24 V X10.3 DI5

*) Not connected

Connection diagram for CU240D PN and CU240D PN-F Control Units

6/10

Siemens D 11.1 2009

G_D011_EN_00209

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
CU240D Control Units

Technical specifications
Control Unit CU240D DP CU240D PN CU240D DP-F CU240D PN-F 6SL3544-0FA20-1PA0 6SL3544-0FA20-1FA0 6SL3544-0FA21-1PA0 6SL3544-0FA21-1FA0 external 24 V DC necessary external 24 V DC necessary external 24 V DC necessary external 24 V DC necessary

Electrical specifications
Operating voltage Current consumption 1) (from the 24 V supply) with Power Module frame sizes FSA and FSB with Power Module frame size FSC 200 mA 350 mA 6 2 PROFIBUS DP 1 350 mA 500 mA 6 2 PROFINET 1 200 mA 350 mA 6 2 PROFIBUS DP, PROFIsafe 1 350 mA 500 mA 6 2 PROFINET, PROFIsafe 1

Interfaces
Digital inputs Digital outputs (0.5 A, fed through switched 24 V DC) Bus interface Encoder interfaces (HTL incremental interface, bipolar up to 2048 pulses, max. 100 mA) PTC/KTY interface (connection via Power Module) Motor temperature sensor

1 input, sensors that can be connected: PTC, KTY or Thermo-Click

1 input, sensors that can be connected: PTC, KTY or Thermo-Click

1 input, sensors that can be connected: PTC, KTY or Thermo-Click

1 input, sensors that can be connected: PTC, KTY or Thermo-Click

Control of a mechanical motor brake (connection via Power Module) MMC memory card slot RS232 interface (connected with RS232 interface cable or USB interface cable via the optical interface of the Control Unit)

Safety functions
Integrated safety functions Acc. to Category 3 of EN 954-1 and acc. to SIL 2 of IEC 61508 Safe Stop 1 (SS1) Safe Stop 1 (SS1) Safely Limited Speed Safely Limited Speed (SLS) (SLS) Safe Torque Off (STO) Safe Torque Off (STO) The safety functions Safely Limited Speed and Safe Stop 1 are not certified for pull-through loads such as e.g. hoisting gear and unwinders. The safety functions Safely Limited Speed and Safe Stop 1 are not certified for pull-through loads such as e.g. hoisting gear and unwinders.

Open-loop/closed-loop control techniques


V/f linear/square/parameterizable V/f with flux current control (FCC) Vector control, without encoder Vector control, with encoder Torque control, without encoder Torque control, with encoder

1)

The current consumption of connected encoders and sensors (total, max. 300 mA) as well as the current drawn from the digital outputs must be added.

Siemens D 11.1 2009

6/11

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
CU240D Control Units

Technical specifications
Control Unit CU240D DP CU240D PN CU240D DP-F CU240D PN-F 6SL3544-0FA20-1PA0 6SL3544-0FA20-1FA0 6SL3544-0FA21-1PA0 6SL3544-0FA21-1FA0 16, parameterizable 16, parameterizable IP65 10 +50 C (14 122 F) 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible 150 mm 210 mm 40 mm 0.7 kg 16, parameterizable IP65 0 55 C (32 131 F) 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible 150 mm 210 mm 40 mm 0.7 kg 16, parameterizable IP65 0 50 C (32 122 F) 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible 150 mm 210 mm 40 mm 0.7 kg

Software functions
Fixed frequencies Automatic restart after line supply failure or operational fault Positioning down ramp Slip compensation Signal interconnection with BICO technology

Free function blocks (FFB) for logic and arith- metic operations Ramp smoothing 3 selectable drive data sets 3 selectable command data sets (CDS) (manual/auto) Flying restart JOG Technology controller (PID) Thermal motor protection Thermal inverter protection Setpoint input Motor identification IP65 10 +55 C (14 131 F) 40 +70 C (40 +158 F) < 95 % RH, condensation not permissible 150 mm 210 mm 40 mm 0.7 kg

Motor holding brake Degree of protection Operating temperature Storage temperature Relative humidity Dimensions Width Height Depth Weight, approx.

Mechanical specifications and ambient conditions

6/12

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Overview
The regenerative feedback capability of the PM250D Power Module in generator mode (electronic braking) means that energy is returned to the supply system and is not wasted in a braking resistor. This saves space, time-consuming dimensioning of the braking resistor as well as its wiring. The amount of generated heat is also reduced. For further information, please refer to part Innovation, section Efficient Infeed Technology. An innovative circuit design reduces the line harmonics. A line reactor is not required. This saves space and costs for configuration and procurement. The PM250D Power Module is also designed for safety-oriented applications. In conjunction with a Fail-safe Control Unit, the drive can be turned into a Safety Integrated Drive (see Control Units). The PM250D Power Modules with integrated class A line filter are suitable for connection to TN and TT supply systems.
Example of PM250D Power Module frame size FSA

Selection and ordering data


Rated power 1) Rated output current 2) Input current Frame size SINAMICS G120D PM250D Power Module with integrated class A line filter Order No. FSA FSA FSB FSC FSC FSC 6SL3525-0PE17-5AA0 6SL3525-0PE21-5AA0 6SL3525-0PE23-0AA0 6SL3525-0PE24-0AA0 6SL3525-0PE25-5AA0 6SL3525-0PE27-5AA0

kW

hp 1 1.5 4 5 7.5 10
3)

A 2.2 4.1 7.7 10.2 13.2 19.0

A 2.1 3.8 7.2 9.5 12.2 17.7

380 500 V 3 AC
0.75 1.5 3 4 5.5 7.5

1)

Rated power based on the rated output current Irated. The rated output current Irated is based on the duty cycle for high overload (HO).

2)

The rated output current Irated is based on the duty cycle for high overload (HO). These current values are valid for 400 V and are stamped on the rating plate of the Power Module. It is not possible to make any assignment to a particular standard.

3)

Siemens D 11.1 2009

6/13

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Integration
PM250D Power Modules communicate with the Control Unit via the PM-IF interface. PM250D Power Modules have the following interfaces as standard: PM-IF interface to connect the PM250D Power Module to the Control Unit. Motor connection via a HAN Q8 (connector) including control of the motor brake and temperature sensor Line supply connection via HAN Q4/2 (socket)

ext. 24 V DC required 24 V 0V

380 V to 500 V 3 AC L1 L2 L3 PE

HAN Q4/2

L1

L2

L3

*)

*)

*)

PE

11

12

PE

Power Module PM250D

Line filter class A


3

~
=

Control Unit

PM-IF Interface

=
G_D011_EN_00120a

8 -

4 -

6 +

2 *)

PE PE

1 U

7 V

3 W

HAN Q8

M 3~
*) Not used 1) Potential refers to DC link.

Motor brake 1) Temperature sensor 1)

Please consider this when selecting the motor cable.

Connection diagram for PM250D Power Module with integrated class A line filter

6/14

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Technical specifications
General technical specifications
PM250D Power Modules System operating voltage Line supply requirements Line short circuit voltage uK Input frequency Output frequency Control type V/f Control type Vector Pulse frequency Power factor Inverter efficiency Modulation depth Overload capability High overload (HO) Average maximum rated output current during a cycle time of 300 s 1.5 rated output current (i.e. 150 % overload) over 60 s at a cycle time of 300 s 2 rated output current (i.e. 200 % overload) over 3 s at a cycle time of 300 s Integrated class A line filter according to EN 55011 Energy recovery in generator mode (max. with rated power possible); Integrated brake control supplies the DC supply voltage for the brake Line voltage Rectified brake voltage Degree of protection Operating temperature Storage temperature Permissible mounting position Relative humidity Cooling Installation altitude Standard SCCR (Short Circuit Current Rating) 1) Protection functions IP65 10 +55 C (operating temperature ranges of the Control Units should be taken into account) 40 +70 C (40 +158 F) Horizontal wall mounting and mounting in the horizontal position < 95 % RH, condensation not permissible FSA and FSB: Convection FSC: Air cooling as required using the integrated fan up to 1000 m above sea level without power reduction, > 1000 m see derating characteristics 10 kA Undervoltage Overvoltage Overcontrol/overload Ground fault Short circuit Stall protection Motor blocking protection Motor overtemperature Inverter overtemperature Parameter locking UL 508C (UL list number E121068), cUL, CE, c-tick According to Low-Voltage Directive 73/23/EEC and Machinery Directive 98/37/EC 380 V AC 171 V DC 400 V AC 180 V DC 440 V AC 198 V DC 480 V AC 216 V DC 500 V AC 225 V DC 0 650 Hz 0 200 Hz 4 kHz (standard), higher pulse frequencies up to 16 kHz, see the derating data 0.95 95 97 % 87 % 380 500 V 3 AC 10 % 1% 47 63 Hz

Electromagnetic compatibility Possible braking methods

Disconnection on the DC side permits fast braking (max. output current 1 A)

Standards conformance CE mark

1)

Applies to industrial control cabinet installations to NEC Article 409/UL 508A. For further information, visit us on the Internet at: http://support.automation.siemens.com/WW/view/en/23995621

Siemens D 11.1 2009

6/15

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Technical specifications
Line supply voltage 380 500 V 3 AC Rated output current Irated Output current Imax Rated power Rated pulse frequency Efficiency Power loss Cooling air requirement Sound pressure level LpA (1 m) Rated input current 2) Line supply connection U1/L1, V1/L2, W1/L3, PE Conductor cross-section Motor connection U2, V2, W2, PE, motor brake, temperature sensor Conductor cross-section Motor cable length, max. Degree of protection Dimensions mm2 m mm2 kW m
3/s 1)

PM250D Power Modules 6SL3525-0PE17-5AA0 A A kHz 2.2 4.4 4 0.97 0.047 0.004 2.1 HAN Q4/2 (connector) 1.5 6 HAN Q8 (socket) 6SL3525-0PE21-5AA0 4.1 8.2 1.5 (1.5) 3) 4 0.97 0.061 0.005 3.8 HAN Q4/2 (connector) 1.5 6 HAN Q8 (socket) 6SL3525-0PE23-0AA0 7.7 15.4 3.0 (4.0) 4 0.97 0.103 0.009 7.2 HAN Q4/2 (connector) 2.5 6 HAN Q8 (socket)

kW (hp) 0.75 (1.0)

dB A

14 15 IP65

14 15 IP65 450 210 110 FSA 5.7

2.5 4 15 IP65 450 210 180 FSB 8

Width Height Depth Frame size Weight, approx.

mm mm mm kg

450 210 110 FSA 5.7

1) 2)

The rated output current Irated is based on the duty cycle for high overload (HO). The input current depends on the motor load and line impedance. The input currents apply for load at rated power for a line impedance corresponding to uK = 1 %.

3)

It is not possible to make any assignment to a particular standard.

6/16

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Technical specifications
Line supply voltage 380 500 V 3 AC Rated output current Irated Output current Imax Rated power Rated pulse frequency Efficiency Power loss Cooling air requirement Sound pressure level LpA (1 m) Rated input current 2) Line supply connection U1/L1, V1/L2, W1/L3, PE Conductor cross-section Motor connection U2, V2, W2, PE, motor brake, temperature sensor Conductor cross-section Motor cable length, max. Degree of protection Dimensions Width Height Depth Frame size Weight, approx. kg mm mm mm 450 210 220 FSC 8.5 450 210 220 FSC 8.5 450 210 220 FSC 8.5 mm2 m mm2 kW m
3/s 1)

PM250D Power Modules 6SL3525-0PE24-0AA0 A A kHz 10.2 20.4 4 0.97 0.141 0.012 74.5 9.5 HAN Q4/2 (connector) 2.5 6 HAN Q8 (socket) 6SL3525-0PE25-5AA0 13.2 26.4 5.5 (7.5) 4 0.97 0.209 0.018 74.5 12.2 HAN Q4/2 (connector) 46 HAN Q8 (socket) 6SL3525-0PE27-5AA0 19 38 7.5 (10) 4 0.97 0.295 0.025 74.5 17.7 HAN Q4/2 (connector) 46 HAN Q8 (socket)

kW (hp) 4 (5)

dB A

2.5 4 15 IP65

4 15 IP65

4 15 IP65

1)

The rated output current Irated is based on the duty cycle for high overload (HO).

2)

The input current depends on the motor load and line impedance. The input currents apply for load at rated power for a line impedance corresponding to uK = 1 %.

Siemens D 11.1 2009

6/17

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Characteristic curves
Derating data Pulse frequency
Rated power at 400 V 3 AC kW 0.75 1.5 3.0 4.0 5.5 7.5 hp 1.0 1.5 1) 4.0 5.0 7.5 10 Rated output current in A for a pulse frequency of 4 kHz 2.2 4.1 7.7 10.2 13.2 19 6 kHz 1.9 3.5 6.5 8.7 11.2 16.2 8 kHz 1.5 2.9 5.4 7.1 9.2 13.3 10 kHz 1.3 2.5 4.6 6.1 7.9 11.4 12 kHz 1.1 2.1 3.9 5.1 6.6 9.5 14 kHz 1.0 1.8 3.5 4.6 5.9 8.6 16 kHz 0.9 1.6 3.1 4.1 5.3 7.6

Ambient temperature
100 % 75
G_D011_EN_00124

Installation altitude
100 % 90 80 70 60 0

Permissible output current

25

-10

10

20

30

40

50 C 55 60

1000

Ambient temperature

2000 3000 m Installation altitude above sea level

4000

Note: The operating temperature ranges of the Control Units should be taken into account. The temperature ranges are specified in the technical specifications under Control Units.
Permissible input voltage

100 % 90 80 77 70 60 0

1000

2000 3000 m Installation altitude above sea level

4000

1)

It is not possible to make any assignment to a particular standard.

6/18

Siemens D 11.1 2009

G_D011_EN_00105

G_D011_EN_00104

55 50

Permissible output current

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
PM250D Power Modules

Dimensional drawings
110 (4.33) 210 (8.27)

G_D011_EN_00121a

Drill pattern

450 (17.72)

425 (16.73)

PM250D Power Module frame size FSA with integrated class A line filter and plugged on Control Unit

180 (7.08)

195 (7.68)

210 (8.27)

G_D011_EN_00122a

Drill pattern

450 (17.72)

425 (16.73)

PM250D Power Module frame size FSB with integrated class A line filter and plugged on Control Unit

210 (8.27)

220 (8.66)

G_D011_EN_00123a

Drill pattern

450 (17.72)

425 (16.73)

PM250D Power Module frame size FSC with integrated class A line filter and plugged on Control Unit

Mounted using M5 or M6 screwed joints with a maximum washer diameter of 12 mm. 3 mm allen screw for the Control Unit.

Ventilation clearance required (for wall mounting) at top and bottom: 150 mm (5.9 inches). All dimensions in mm (values in brackets are in inches).

195 (7.68)

195 (7.68)

Siemens D 11.1 2009

6/19

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Recommended line components

Overview
The following table lists recommendations for additional lineside components, such as fuses and circuit breakers (line-side components dimensioned in accordance with IEC standards). The specified circuit breakers are UL-certified. 3NA3 fuses are recommended for European countries. The values in the table take into account the overload capability of the inverter. Additional information about the listed fuses and circuit breakers can be found in Catalogs LV 1 and LV 1 T.

Selection and ordering data


For individual protection
Rated power kW 0.75 1.5 3 4 5.5 7.5 hp 1 1.5 1) 4 5 7.5 10 SINAMICS G120D PM250D Power Modules Type 6SL3525-... 0PE17-5AA0 0PE21-5AA0 0PE23-0AA0 0PE24-0AA0 0PE25-5AA0 0PE27-5AA0 Frame size FSA FSA FSB FSC FSC FSC Protection A 10 10 26 20 20 32 Fuse Order No. 3NA3803 3NA3803 3NA3805 3NA3807 3NA3807 3NA3812 Circuit breaker Order No. 3RV1021-1FA10 3RV1021-1JA10 3RV1021-4AA10 3RV1021-4BA10 3RV1031-4EA10 3RV1031-4FA10

380 ... 500 V 3 AC

Group protection The group protection designates those configurations in which a circuit-breaker or a fuse provides protection for two or several devices and their feeder cables. The protective device is known as branch protection (BCP) device. You will find additional information on the group protection and recommended types in the FAQ: http://support.automation.siemens.com/ww/view/en/31560253

1)

It is not possible to make any assignment to a particular standard.

6/20

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Intelligent Operator Panel IOP Handheld Updating the IOP Handheld The IOP Handheld can be updated and expanded using the integrated USB interface. Data to support future drive systems can be dragged from the PC and dropped into the IOP Handheld. Further, the USB interface allows user languages and Wizards that become available in the future to be subsequently downloaded and the firmware updated for the IOP Handheld. The IOP is supplied with power via the USB interface during an update. Selection and ordering data
Designation IOP Handheld For use with SINAMICS G120, SINAMICS G110D, SINAMICS G120D, SIMATIC ET 200S FC or SIMATIC ET 200pro FC Included in the scope of delivery: IOP Handheld housing Rechargeable batteries (4 AA) Charging unit (international) RS232 connecting cable (3 m long, can only be used for SINAMICS G120 and SIMATIC ET 200S FC) USB cable (1 m long) RS232 interface cable With optical interface to connect the SINAMICS G110D, SINAMICS G120D or SIMATIC ET 200pro FC inverters to the IOP Handheld (2.5 m long)
new

Order No. 6SL3255-0AA00-4HA0

IOP Handheld for mobile use

The Intelligent Operator Panel IOP Handheld is a very userfriendly and powerful operator panel for commissioning and diagnostics as well as local operator control and monitoring of the SINAMICS G120D distributed inverter. The IOP supports both entry-level personnel and drive experts. Thanks to the large plain text display, the menu prompting and the Application Wizards, it is easy to commission standard drives. A drive can be essentially commissioned without having to use a printed parameter list as the parameters are displayed in plain text, explanatory help texts are provided and the parameter filtering function. Application Wizards interactively guide you when commissioning important applications such as conveyor technology, pumps, fans and compressors. There are Quick Commissioning Wizards for general commissioning. The drives are manually and simply controlled using directly assigned buttons and the navigation wheel. The IOP Handheld has a dedicated switchover key to switch over from the automatic to the manual mode. The inverter can be diagnosed in a user-friendly fashion using the plain text display of faults and alarms. Help texts can be obtained by pressing the INFO button. Up to two process values can either be graphically or numerically visualized on the status screen/status display. Process values can also be displayed in technological units. The IOP Handheld supports series commissioning of identical drives. For this purpose, a parameter list can be copied from an inverter into the IOP Handheld and when required, downloaded into other drive units of the same type. The IOP Handheld includes the following language packages: German, English, French, Italian and Spanish. In addition to the IOP, the IOP Handheld includes a housing with the rechargeable batteries, charging unit and RS232 interface cable. The charging unit is supplied with connector adapters for Europe, the US and UK. When the batteries are fully charged, the operating time is up to 8 hours. To connect the IOP Handheld to SINAMICS G120D, in addition, the RS232 interface cable with optical interface is required.

6
3RK1922-2BP00

Siemens D 11.1 2009

6/21

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
MMC memory card RS232 interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC over a point-to-point link if the appropriate software (STARTER commissioning tool 1), from Version 4.1, SP1 and higher) has been installed. Selection and ordering data
Order No. RS232 interface cable for communication with a PC 3RK1922-2BP00

USB interface cable for communication with a PC For controlling and commissioning an inverter directly from a PC over a point-to-point link if the appropriate software (STARTER commissioning tool 1), from Version 4.1, SP1 and higher) has been installed. Selection and ordering data
Order No. USB interface cable for communication with a PC (2.5 m long)
new

6SL3555-0PA00-2AA0

STARTER Commissioning Tool The parameter settings for an inverter can be stored on the MMC memory card. When service is required, e.g. after the inverter has been replaced and the data have been downloaded from the memory card the drive system is immediately ready for use again. Selection and ordering data
Order No. MMC memory card 6SL3254-0AM00-0AA0

The STARTER commissioning tool (from STARTER Version 4.1, SP1 and higher) supports the commissioning and maintenance of SINAMICSG120D inverters. The operator guidance combined with comprehensive, user-friendly functions for the relevant drive solution allow you to commission the device quickly and easily. Selection and ordering data
Order No. STARTER commissioning tool 1) on DVD 6SL3072-0AA00-0AG0

1)

The STARTER commissioning tool is also available on the Internet under http://support.automation.siemens.com/WW/view/en/10804985/133100

6/22

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Connecting cable for the Control Unit PROFINET connecting cable Flexible plug-in cables and connectors that can be assembled in the field for transmission of data (up to 100 Mbit/s) between Industrial Ethernet participants with IP65 degree of protection. Selection and ordering data
Order No. IE connecting cable M12-180/M12-180 Pre-fabricated IE FC TP trailing cable GP 2 2 PROFINET type C) with two 4-pin M12 connectors (4-pin, D-coded), IP65/IP67 degree of protection Length: 0.3 m 0.5 m 1.0 m 1.5 m 2.0 m 3.0 m 5.0 m 10 m 15 m IE M12 Plug PRO For assembly in the field, M12 connector (D-coded), metal housing, fast connection method, for SCALANCE X208PRO and IM 154-4 PN 1 unit 8 units 6GK1901-0DB10-6AA0 6GK1901-0DB10-6AA8 M12 plug-in cable With PUR sheath, to connect digital sensors and actuators, pre-fabricated at one end, angled, plug connector, 5-pole, 5 0.34 mm2 length: 1.5 m Order No. PROFIBUS M12 plug-in cable Pre-fabricated with two 5-pole M12 connectors/sockets Length: 0.3 m 0.5 m 1.0 m 1.5 m 2.0 m 3.0 m 5.0 m 10 m 15 m PROFIBUS M12 connectors 5-pole, B-coded, metal enclosure, 1 package = 5 units Pin insert Socket insert 6GK1905-0EA00 6GK1905-0EB00 6XV1830-3DE30 6XV1830-3DE50 6XV1830-3DH10 6XV1830-3DH15 6XV1830-3DH20 6XV1830-3DH30 6XV1830-3DH50 6XV1830-3DN10 6XV1830-3DN15 5m 10 m
new new new

Connecting cables/connectors for supplying the Control Unit with power Selection and ordering data
Order No. 7/8" plug-in cable For power supply, pre-fabricated with two 5-pole 7/8" plug/socket connectors Length: 0.3 m 0.5 m 1.0 m 1.5 m 2.0 m 3.0 m 5.0 m 10 m 15 m 7/8"-connector 5-pole, B-coded, plastic enclosure, 1 package = 5 units Pin insert Socket insert 6GK1905-0FA00 6GK1905-0FB00 6XV1822-5BE30 6XV1822-5BE50 6XV1822-5BH10 6XV1822-5BH15 6XV1822-5BH20 6XV1822-5BH30 6XV1822-5BH50 6XV1822-5BN10 6XV1822-5BN15

6XV1870-8AE30 6XV1870-8AE50 6XV1870-8AH10 6XV1870-8AH15 6XV1870-8AH20 6XV1870-8AH30 6XV1870-8AH50 6XV1870-8AN10 6XV1870-8AN15

Connecting cables for digital inputs Selection and ordering data


Order No.

PROFIBUS connecting cable Flexible plug-in cables/connectors for transmission of data (up to 12 Mbit/s) from PROFIBUS participants. Selection and ordering data

3RX8000-1CE52-1AB5 3RX8000-1CE52-1AF0 3RX8000-1CE52-1AL0

Siemens D 11.1 2009

6/23

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Connecting cables for Power Modules Connecting cables pre-fabricated at one end and connector sets to connect to the line supply Selection and ordering data
Order No. Connecting cable pre-fabricated at one end Power supply cable, open at one end, for HAN Q4/2, angled, 4 4 mm2 1.5 m long 5 m long Connector set for the power supply HAN Q4/2 2.5 mm2 4 mm2 6 mm2 3RK1911-2BE50 3RK1911-2BE10 3RK1911-2BE30 3RK1911-0DB13 3RK1911-0DB33

Motor cables pre-fabricated at one end and connector sets to connect the Power Module to the motor Selection and ordering data
Motor cables pre-fabri- Order No. cated at one end (HTG: supplied from the Harting Company) For motors with brake (ZKT: supplied from the KnorrTec Company) and temperature sensor with HAN Q8 connector, shielded Cross-section 1.5 m long
new

1 mm2 ZKT: 70018601000150

1.5 mm2 HTG: 61 88 201 0288


new

2.5 mm2 HTG: 61 88 201 0291 ZKT: 70009601000150 HTG: 61 88 201 0292
new new

4 mm2 HTG: 61 88 201 0303 ZKT: 70017001000150 HTG: 61 88 201 0304


new

3 m long
new

HTG: 61 88 201 0289 ZKT: 70018601000300 HTG: 61 88 201 0290


new

ZKT: 70009601000300 HTG: 61 88 201 0293 ZKT: 70009601000500 HTG: 61 88 201 0301 ZKT: 70009601001000

ZKT: 70017001000300 HTG: 61 88 201 0305 ZKT: 70017001000500 HTG: 61 88 201 0306 ZKT: 70017001001000

5 m long ZKT: 70018601000500 10 m long


new

new

new

HTG: 61 88 201 0299 ZKT: 70018601001000


new

new

Connector set for motor cables Shielded, HAN Q8 up to 1.5 mm2 Connector set for motor cables Shielded, HAN Q8 up to 2.5 mm2 up to 4 mm2

Order No.

6ES7194-1AB01-0XA0

Order No. (HTG: supplied from the Harting Company) (ZKT: supplied from the KnorrTec Company)
new new

HTG: 61 83 401 0132 ZKT: 10032011


new new

HTG: 61 83 401 0133 ZKT: 10032021

6/24

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Supplementary system components

Accessories
Power bus distribution 400 V in IP65 degree of protection
Ordering (see Solution Partner) Power T clamp connector for 2.5 ... 6 mm2 With attached 7-pole connector, socket insert, grommet housing, UL Seals for various cable cross-sections must be separately ordered T clamp connector Completely pre-fabricated T distributor box, IDC connection, power cable Uncut power cable, 2.5 ... 6 mm2, 2 outgoing feeders: Push-in connection: 1.5 ... 6 mm2 Seals for various cable cross-sections must be separately ordered T distributor box Completely pre-fabricated Ordered and supplied from the Harting Company

Additional information For further information about the connecting cables and plug-in connectors mentioned above, please refer to Catalog IK PI. Further selected accessories are available from Siemens Solution Partners. Select Distributed Field Installation System as technology in the SolutionPartner Finder. http://www.siemens.com/automation/partnerfinder

Ordered and supplied from the KnorrTec Company Ordered and supplied from the Weidmller Company

Ordered and supplied from the KnorrTec Company

Siemens D 11.1 2009

6/25

Siemens AG 2009

SINAMICS G120D
Distributed inverters 0.75 kW to 7.5 kW (1.0 hp to 10 hp)
Spare parts Spare Parts Kit Spare parts Replacement fan

Overview
A Spare Parts Kit can be ordered which comprises small parts such as replacement seals, caps, PROFIBUS address windows and screws.

Overview
The Power Module fans are designed for extra long service life. Replacement fans can be ordered for special applications.

Selection and ordering data


Order No. Spare Parts Kit for SINAMICS G120D comprising replacement seals, caps, PROFIBUS address windows and screws 6SL3500-0SK01-0AA0

Selection and ordering data


Rated power kW hp SINAMICS G120D PM250D Power Module Type 6SL3525-... 0PE24-0AA0 0PE25-5AA0 0PE27-5AA0 Replacement fan Frame size Order No.

380 500 V 3 AC
4.0 5.5 7.5 5.0 7.5 10 FSC 6SL3500-0SF01-0AA0 (pre-mounted unit with cover, fan and screws)

6/26

Siemens D 11.1 2009

Siemens AG 2009

Tools and configuration


7/2 7/2 7/3 7/3 7/4 7/4 7/4 7/5 7/5 7/5 7/6 7/6 7/7 7/7 7/7 7/7 7/8 7/8 7/8

7
SD Configurator selection guide Overview Selection and ordering data Additional information SIZER configuration tool Overview Selection and ordering data STARTER commissioning tool Overview Selection and ordering data Accessories Additional information Drive ES engineering system Overview Selection and ordering data Additional information SinaSave energy-saving program Overview Additional information

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
SD Configurator selection guide

Overview
Product description The SD Configurator has been developed to facilitate the selection of a correct motor and/or inverter from the wide range of Standard Drives. The configurator is available as selection guide offline within the Interactive Catalog CA 01 (DVD) and online in the Siemens Mall. The SD Configurator is used to help locate the correct drive solution and delivers both the correct order number and relevant documentation. 3D models in a wide variety of 3D formats are also available.

Data sheet for three-phase Squirrel-Cage-Motors


Datenblatt fr Drehstrom-Kfiglufermotoren

Ordering data / Bestelldaten:


1LE1001-1AD52-2AA4
client-order-no. Kunden-Auftrags-Nr.: order-no. Siemens-Auftrags-Nr.: offer-no. Angebots-Nr.: item-no. Item-Nr.: consignment-no. Komm.-Nr.: project Anlage:

Electrical data / Elektrische Daten:


rated motor voltage
Bemessungsspannung 230VD/400VY 50Hz, 460VY 60Hz 230VD/400VY 50Hz, 460VY 60Hz 50 Hz 1,10 kW 725 1/min 14,0 Nm VD VY 4,2 A 3,8 2,9 1,7 non-applicable nicht anwendbar 75%/50Hz 64,5 % 0,48 without (Standard) ohne (Standard) terminal box - on top Klemmenkasten oben 4,1 2,9 1,7 875 1/min 14,0 Nm VY 3,5 A 60 Hz

general data / Allgemeine Daten:


frame size
Baugre 100L IM B3 IM B3 25.0 kg Aluminum Aluminium IP 55 IC 411 A (Standard) 155(F) to 130(B) 155(F) nach 130(B) S1 = continuous operation S1 = Dauerbetrieb bidirectional bidirektional

frequency
Frequenz

type of construction
Bauform

rated motor power


Bemessungsleistung

weight in kg, without optional accessories


Gewicht in kg , ohne optionale Anbauten

rated motor speed


Bemessungsdrehzahl

frame material
Gehusematerial

rated motor torque


Bemessungsmoment

degree of protection
Schutzart

rated motor current


Bemessungsstrom

method of cooling, TEFC


Khlart, TEFC

7,2 A

starting- / rated motor current


Anzugs-/ Bemessungsstrom

vibration class
Vibrationsklasse

breakdown / rated motor starting- / rated motor torque


Anzugs-/Bemessungsmoment

insulation
Isolation

The comprehensive help system not only explains the program functions, but also provides access to detailed technical background knowledge. Product range The SD Configurator covers the product range of low-voltage motors (energy-saving and explosion-proof motors) with the associated documentation and dimensional drawings, low-voltage inverters in the MICROMASTER 4 range, standard SINAMICS G110 and SINAMICS G120 inverters, as well as distributed SINAMICS G120D inverters and the SIMATIC ET 200S FC and SIMATIC ET 200pro drive converters. Hardware and software requirements PC with 1.5 GHz CPU or faster Operating systems - Windows 98/ME - Windows 2000 - Windows XP - Windows NT (from Service Pack 6 and higher) - Windows Vista At least 1024 MB RAM user memory Screen resolution 1024 768, graphics with more than 256 colors/small fonts DVD drive Windows-compatible sound card Windows-compatible mouse

duty type
Betriebsart

efficiency class
Wirkungsgradklasse 100%/50Hz

direction of rotation
Drehrichtung 100%/60Hz 58,0 % 0,37

efficiency
Wirkungsgrad

67,0 % 0,57

terminal box / Klemmenkasten:


material of terminal box
Klemmenkastenmaterial Aluminum Aluminium TB1 F00 M4 4.0 mm 11.0 mm - 21.0 mm 2xM32x1,5 2 plugs 2 Stopfen - Kunststoff

power factor
Leistungsfaktor

motor protection
Motorschutz

type
Typ

terminal box position


Klemmenkastenlage

terminal screw thread


Gewinde Kontaktschraube

Mechanical data/ Mechanische Daten:


noise 50 Hz/60Hz
Schalldruckpegel (LpfA) 50 Hz/60Hz 66,00 dB 0,00 dB

max. cable cross-sectional area


Max. Leiterquerschnitt

cable diameter from ... to ...


Kabeldurchmesser von ... bis ... 0,010900 kg m 6206 2ZC3 6206 2ZC3 pre-stressed Bearing NDE Vorgespanntes Lager BS No Nein No Nein Esso Unirex N3 20000 h -g

moment of inertia
Trgheitsmoment

cable entry
Kabeleinfhrung

bearing AS
Lager AS

cable gland
Kabelverschraubung

bearing BS
Lager BS

special configurations/ Sonderausfhrung:

locating bearing
Art der Lagerung

drain holes
Kondenswasserlcher

regreasing device
Nachschmiereinrichtung

type of lubrication
Schmiermittel

relubrication interval at 40C


Fettgebrauchsdauer: 40C

quantity of grease for relubrication at 40C


Fettmenge Nachschmierung :40C

external earthing
uere Erdungsklemme

paintwork
Anstrich

No Nein Special finish in RAL 7030 stone gray Sonderanstrich RAL7030 steingrau

type of protection
Zndschutzart

without (Standard) ohne (Standard)

site conditions/ Umgebungsbedingungen:


ambient temperature
Umgebungstemperatur -20.0 C - +40.0 C 1000 m IEC, DIN, ISO, VDE, EN

altitude above sea level


Hhe ber Meeresspiegel

standards and specifications


Normen und Vorschriften

Technical and ordering data are subject to change. There may be descrepancies between calculated ad rating plate values.Technische nderungen vorbehalten!

It can display operating instructions, factory test certificate, terminal box documentation, etc. and generates data sheets, dimensional drawings and a start-up calculation for the relevant products. It can also be used to identify a suitable inverter for the selected motor.

7/2

Siemens D 11.1 2009

G_D011_EN_00188

explosion protection / Explosionsschutz:

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
SD Configurator selection guide

Overview
Offline access in the Catalog CA 01 the Offline Mall

Selection and ordering data


Description Interactive Catalog CA 01 on DVD including selection guide, SD Configurator, English Order No. E86060-D4001-A510-C77600

Additional Information
The Interactive Catalog CA 01 can be ordered from the relevant Siemens sales office or via the Internet: http://www.siemens.com/automation/CA01 Links to tips, tricks and downloads for functional or content updates can be found at this address. For technical support and hotline support, you can also contact our Hotline for the Catalog CA 01: Phone.: +49 (0) 180 50 50 22 2 e-Mail: [email protected] More than 100,000 products with approx. 5 million possible product versions from the area of drive technology are listed in the Interactive Catalog CA 01 the Offline Mall of Siemens Industry Automation and Drive Technologies (IA & DT). The Catalog CA 01 can be directly installed on the hard disk or in the network from the DVD as a partial or full version. The SD Configurator can then be found in the main menu of the CA 01 under the Selection guide tab. Online access in the Siemens Mall In addition, the SD Configurator can now be used on the Internet without requiring any installation. The SD Configurator can be found in the Siemens Mall under the following address: http://www.siemens.com/dt-configurator

Siemens D 11.1 2009

7/3

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
SIZER configuration tool

Overview

The configuration process results are: A parts list of the required components (export to Excel, use of the Excel data sheet for import to VSR) Technical specifications of the system Characteristic curves Comments regarding line harmonics Layout diagram of drive and control components and dimensional drawings of motors These results are displayed in a results tree and can be reused for documentation purposes. Technological online help is available: Detailed technical specifications Information about the drive systems and their components Decision-making criteria for the selection of components Online help in German, English, French, Italian, Chinese and Japanese Minimum system requirements Programming device or PC with Pentium II 400 MHz (Windows 2000), Pentium III 500 MHz (Windows XP) 512 MB RAM (1024 MB recommended) At least 2.7 GB of free hard disk space An additional 100 MB of free hard disk space on Windows system drive Screen resolution 1024 768 pixels Windows 2000 SP4 / XP Professional SP2 / XP Home Edition SP2 Microsoft Internet Explorer 5.5 SP2

The following drives and controls can be engineered in a userfriendly fashion using the SIZER configuration tool: The SINAMICS range of drives MICROMASTER 4 family of drives SINUMERIK solution line CNC control SIMOTION motion control SIMATIC Technology It provides support when selecting and dimensioning the hardware and firmware components required for the drive task. SIZER supports the configuration of the complete drive system and allows simple single-motor drives up to complex multi-axis applications to be engineered.

Selection and ordering data


Order No. SIZER configuration tool for SINAMICS and MICROMASTER German, English, French, Italian 6SL3070-0AA00-0AG0

SIZER supports all of the engineering steps in a workflow: Configuring the line supply infeed Selecting and dimensioning motors and gear units, including calculation of the mechanical transmission elements Configuring the drive components Compiling the required accessories Selecting the line-side and motor-side power options, e.g. cables, filters, and reactors When SIZER was being designed, particular importance was placed on a high degree of usability and an universal, functionbased approach to the drive application. The extensive user guidance makes using the tool easy. Status information keeps the user continually informed about how the configuration is progressing. The SIZER user interface is available in German, English, French and Italian. The drive configuration is saved in a project. In the project, the components and functions used are displayed in a hierarchical tree structure. The project view allows the configuration of drive systems and already engineered drives to be copied/inserted/modified.

7/4

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
STARTER commissioning tool

Overview

For experts, the expert list can be used to specifically and quickly access individual parameters at any time. An individual compilation of frequently used parameters can be saved in dedicated user lists. In addition, the following function is available for optimization: Self-optimization of the controller settings (depending on drive unit) Diagnostics functions provide information about: Control/status words Parameter status Operating conditions Communication states Performance features User-friendly: Only a few settings have to be made to complete the first commissioning: The motor starts to rotate Solution-oriented dialog-based user guidance simplifies commissioning Self-optimization functions reduce the manual effort required to optimize the drive Minimum hardware and software requirements PG or PC with Pentium III 1 GHz 512 MB RAM (1 GB RAM recommended) Screen resolution 1024 768 pixels, 16-bit color depth Free hard disk memory: 2 GB Windows 2000 SP4, Windows 2003 Server SP1, SP2 Windows XP Professional SP1 or SP2 Windows Vista Business SP1, Windows Vista Ultimate SP1 Microsoft Internet Explorer 6.0

The user-friendly STARTER commissioning tool can be used for: Commissioning Optimizing Diagnostics This software can be operated as autonomous PC application, via Drive ES Basic in conformance with TIA, integrated in SIMATIC STEP 7 as well a integrated to a high level in the SCOUT engineering system (for SIMOTION). The basic functions and handling are the same in both cases. In addition to the SINAMICS drives, in STARTER the MICROMASTER 4 and the SIMATIC ET 200S FC and SIMATIC ET 200pro FC drive converters are also supported. The Project Wizard sets up the drives within the structure of the project tree. Entry level personnel are supported by solution-based dialog guidance, which offers a standardized graphics-based display to make it easy when setting the drive parameters. First commissioning is guided by a Wizard which makes all the basic settings in the drive. Therefore, getting a motor up and running is merely a question of setting a few of the drive parameters as part of the drive configuration process. The individual settings required are made using graphics-based parameterization screens, which also precisely visualize the principle of operation of the drive. Examples of individual settings that can be made include: How terminals are used Bus interface Setpoint channel (e.g. fixed setpoints) Speed control (e.g. ramp-function generator, limits) BICO interconnections Diagnostics

Selection and ordering data


Order No. STARTER commissioning tool for SINAMICS and MICROMASTER German, English, French, Italian, Spanish 6SL3072-0AA00-0AG0

Siemens D 11.1 2009

7/5

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
STARTER commissioning tool Accessories

Accessories
Connection Depending on the Control Unit version, communications between the Control Unit (CU) of the drive unit and the programming device (PG) or PC can be realized via a serial interface, via PROFIBUS or Ethernet/PROFINET. The following accessories are available for the particular drive system as listed in the following table.

Selection and ordering data


Drive series SINAMICS G110 Recommended accessories for communication between the drive device and the programming device or PC via RS233 Order No. PROFIBUS Order No. PROFINET PC Inverter 6SL3255-0AA00-2AA1 Connection Kit The scope of supply includes a 9-pin Sub-D connector, a RS232 standard cable, 3 m, and the STARTER commissioning tool on DVD 6SL3255-0AA00-2AA1 SIMATIC DP plug-in PC Inverter cable Connection Kit 12 MBaud for PG conThe scope of supply nection, pre-fabricated includes a 9-pin Sub-D with 2 9-pole SUB-D connector, a RS232 standard cable, 3 m, connectors, 3 m and the STARTER commissioning tool on DVD PC Inverter Connection Kit for CU230P-2 Control Units The scope of supply includes a USB cable, 3 m, and the STARTER commissioning tool on DVD 6SL3255-0AA00-2AA1 SIMATIC DP plug-in cable 12 MBaud for PG connection, pre-fabricated with 2 9-pole SUB-D connectors, 3 m

SINAMICS G120

6ES7901-4BD00-0XA0 Standard CAT5 Ethernet cable or PROFINET cable required

6ES7901-4BD00-0XA0 -

SINAMICS G110D

USB interface cable for communication with a PC USB interface cable for communication with a PC

6SL3555-0PA00-2AA0

SINAMICS G120D

6SL3555-0PA00-2AA0

Connection to the PROFIBUS system in the plant

Connection to the PROFINET system in the plant

Additional information
The STARTER commissioning tool is also available for update purposes on the Internet under http://support.automation.siemens.com/WW/view/en/10804985/133100

7/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
Drive ES engineering system

Overview

Drive ES PCS 7 Integrates drives with PROFIBUS interface into the SIMATIC PCS 7 process control system. Drive ES PCS 7 requires a pre-installed SIMATIC PCS 7 process control system, from Version 5.2 and higher. Drive ES PCS 7 provides a function block library with function blocks for the drives and the corresponding faceplates for the operator station. This means that the drives can be operated from the PCS 7 process control system. From version V6.1 and higher, drives will also be able to be represented in the PCS7 Maintenance Station.

Selection and ordering data


Order No. Drive ES Basic V5.4 SPx 1) Configuration software for the integration of drives into Totally Integrated Automation Prerequisite: STEP 7 from V5.3, SP 3 and higher Supplied as: DVD, de, en, fr, es, it with electronic documentation

Drive ES is the engineering system used to integrate the communication, configuration and data management functions of Siemens drive technology into the SIMATIC automation world easily, efficiently and cost-effectively. The STEP 7 Manager user interface provides the ideal basis for this. Various software packages are available for SINAMICS: Drive ES Basic For entry into the world of Totally Integrated Automation and the capability of routing beyond network boundaries and the use of the SIMATIC Teleservice. Drive ES Basic is the basic software package for parameterizing all drives, both online and offline. With Drive ES Basic, the automation and drives are processed on the SIMATIC Manager screen. Drive ES Basic is the starting point for common data archiving for complete projects and for extending the use of routing and the SIMATIC Teleservice to drives. Drive ES Basic provides the engineering tools for the new Motion Control functions, slave-to-slave communication, equidistant mode and clock cycle synchronization with PROFIBUS DP and ensures that drives with PROFINET IO are simply integrated into the SIMATIC environment. Drive ES SIMATIC To simply parameterize the STEP 7 communication program instead of programming. Drive ES SIMATIC requires that STEP 7 is installed. It incorporates a SIMATIC block library; this means that the PROFIBUS and/or the PROFINET IO interface can be simply and reliably programmed in the SIMATIC CPU for the drives. There is no need for separate, time-consuming programming of the data exchange between the SIMATIC CPU and the drive. All Drive ES users have to remember is: Copy Modify Download Ready. Coordinated, fully developed function blocks are copied from the library into a user-specific project. Frequently-used functions are completely programmed and ready to run: - Read out complete diagnostics buffer automatically from the drive - Download complete parameter sets automatically from the SIMATIC CPU into the drive, e.g. when a device has to be replaced. - Automatically download partial parameter sets (e.g. for recipe and product change) into the drive from the SIMATIC CPU - Upload the complete parameter assignment or partial parameter sets into the SIMATIC CPU from the drive, i.e. update.

Floating license, 1 user Floating license (copy license), 60 users Update service for single-user license Update service for copy license, 60 users Upgrade from V5.x to V5.4 SPx 1) Drive ES SIMATIC V5.4 SPx 1) Block library for SIMATIC for the parameterization of communication with the drives Prerequisite: STEP 7 from V5.3, SP3 and higher Supplied as: CD-ROM, de, en, fr, es, it with electronic documentation Single-user license incl. 1x runtime license Runtime license (without data carrier) Update service for single-user license Upgrade from V5.x to V5.4 SPx 1) Drive ES PCS7 V6.1 SPx 1) Block library for PCS7 for the integration of drives Prerequisite: PCS7 from V6.1 and higher Supplied as: CD-ROM, de, en, fr, es, it with electronic documentation Single-user license incl. 1x runtime license Runtime license (without data carrier) Update service for single-user license Upgrade from V5.x to V6.x SPx 1) Drive ES PCS7 V7.0 SPx 1) Block library for PCS7 for the integration of drives Prerequisite: PCS7 from V7.0 and higher Supplied as: CD-ROM, de, en, fr, es, it with electronic documentation Single-user license incl. 1x runtime license Runtime license (without data carrier) Update service for single-user license Upgrade from V5.x to V7.x SPx 1)
new new new new

6SW1700-5JA00-4AA0 6SW1700-5JA00-4AA1 6SW1700-0JA00-0AB2 6SW1700-0JA00-1AB2 6SW1700-5JA00-4AA4

6SW1700-5JC00-4AA0 6SW1700-5JC00-1AC0 6SW1700-0JC00-0AB2 6SW1700-5JC00-4AA4

6SW1700-6JD00-1AA0 6SW1700-5JD00-1AC0 6SW1700-0JD00-0AB2 6SW1700-6JD00-1AA4

6SW1700-7JD00-0AA0 6SW1700-5JD00-1AC0 6SW1700-0JD00-0AB2 6SW1700-7JD00-0AA4

Additional information
For additional information go to: http://www.siemens.com/drivesolutions

1)

Orders are always supplied with the latest SP.

Siemens D 11.1 2009

7/7

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Tools and configuration
SinaSave energy-saving program

Overview
The SinaSave energy-saving program is designed for applications with motors fed from the line supply (fixed speed) and from converters (variable speed). For line supply operation, the cost savings as well the payback time for the additional cost of the Siemens EFF1 energy-saving motors can be calculated using the three bases for comparison. In comparison to: Siemens EFF2 energy-saving motors Case 1 Individually selected known motors Case 2 Known motors within an overall plant/system analysis Case 3 The individual application cases are as follows: Case 1 Calculation of the energy cost savings as well as the payback time for the additional costs of the Siemens EFF1 energy-saving motors when compared to Siemens EFF2 energy-saving motors. In this case, the motor data for the Siemens energy-saving motors have already been stored complete with their order numbers. In addition, you will also be told the payback time for the additional costs of an energy-saving motor.

Case 3 Calculation of the energy cost savings as well as the payback time for the additional costs of Siemens EFF1 energy-saving motors when compared to any other known motors plant/system analysis. For converter operation, SinaSave takes into account all the necessary plant/system-specific parameters. Values required for the process such as flowrate and delivery height for pumps, mass flowrate and total pressure difference for fans as well as the density of the transported medium are taken into account in addition to the efficiency of the fan, pump or compressor, the electrical efficiency and the overall efficiency of the plant. Other basic data for the program include the number of working days and work shifts as well as the pumping profile over a day and year decisive data for calculating the actual energy saving. From the plant/system-specific basic data that has been entered, the program initially selects the drive system with the appropriate power rating and a price for a suitable frequency inverter. In a further step, the program determines the energy requirements of the variable-speed drive system for the specific application and compares it to the calculated values for all alternative concepts that can be considered for the plant/system in question; including for example, throttle valves, bypass, vane control or pole-changing motors. The energy-saving is obtained from the difference in kilowatt hours which the program then converts into a cash saving using the currently applicable cost of electrical energy for the plant. The program calculates the payback time from the price of the frequency inverter, the decisive energy-saving and other costreducing effects of variable-speed operation that have also been taken into account, such as an improved power factor and operation that reduces the stress on the equipment in the plant/system.

7
Case 2 Calculation of the energy cost savings as well as the payback time for the additional cost of the Siemens EFF1 energy-saving motors in comparison with other known motors. However, the calculation requires exact knowledge of the technical specifications of the motor which is to be used for the comparison. Product range The SinaSave program includes the product range of low-voltage motors/energy-saving motors and low-voltage inverters from the MICROMASTER 430 and MICROMASTER 440 product series as well as SINAMICS G110, SINAMICS G120 and SINAMICS G150 converters.

Additional information
The program can be downloaded from the Internet using the following link: http://www.siemens.com/energysaving

7/8

Siemens D 11.1 2009

Siemens AG 2009

Services and documentation


8/2 8/2 8/4 8/4 8/4 8/5 8/5 8/6 8/7 8/8 8/9 Training Overview

8
Training case SINAMICS G110 training case SINAMICS G120 training case Documentation SINAMICS G110, SINAMICS G120 SINAMICS G110D, SINAMICS G120D SD Manual Collection My Documentation Manager Customer Support

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120


Services and documentation
Training

Overview
Faster and more applicable know-how: Hands-on training from the manufacturer SITRAIN Siemens Training for Automation and Industrial Solutions provides you with comprehensive support in solving your tasks. Training by the market leader in automation and plant engineering enables you to make independent decisions with confidence. Especially where the optimum and efficient use of products and plants is concerned. You can eliminate deficiencies in existing plants and avoid expensive planning mistakes right from the beginning. SITRAIN highlights Top trainers Our trainers are skilled teachers with direct practical experience. Course developers have close contact with product development, and directly pass on their knowledge to the trainers. Practical experience The practical experience of our trainers enables them to teach theory effectively. But since theory can be pretty drab, we attach great importance to practical exercises which can comprise up to half of of the course time. You can therefore immediately implement your new knowledge in practice. We train you on stateof-the-art methodically/didactically designed training equipment. This training approach will give you all the confidence you need. Wide variety of training courses With a total of about 300 local attendance courses, we provide training for the complete range of Siemens Industry products as well as interaction of the products in systems. Telecourses, teach-yourself software and web-hosted seminars supplement our classic range of courses. Customized training We are only a short distance away. You can find us at more than 50 locations in Germany, and in 62 countries worldwide. You wish to have individual training instead of one of our 300 courses? Our solution: We will provide a program tailored exactly to your personal requirements. Training can be carried out in our Training Centers or at your company. First-class know-how which pays off directly: In shorter commissioning times, high-quality end products, faster troubleshooting and reduced downtimes. In other words, higher profits and lower costs. Achieve more with SITRAIN Shorter times for commissioning, maintenance and service Optimized production operations Reliable engineering and commissioning Minimizing plant downtimes Flexible plant adaptation to market requirements Compliance with quality standards in production Increased employee satisfaction and motivation Shorter familiarization times following changes in technology and staff Visit our Internet site under: http://www.siemens.com/sitrain or let us advise you personally. You can request our latest training catalog from: SITRAIN Customer Support Germany: Phone.: +49 (0)1805 23 56 11 Fax: +49 (0)1805 23 56 12 (0.14 /minute from a German landline network, mobile telephone prices may vary) The right mixture: Blended learning Blended learning means a combination of various training media and sequences. For example, a local attendance course in a Training Center can be optimally supplemented by a teachyourself program as preparation or follow-up. Additional effect: Lower travel costs and shorter times away from work.

8/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120


Services and documentation
Training

Overview
Range of courses for SINAMICS G110 and SINAMICS G120 The courses are modular in design and are intended for a variety of target groups as well as individual customer requirements. An overview course helps decision-makers and sales personnel to acquaint themselves with the SINAMICS drive concept and its position in the existing Siemens drives environment. SITRAIN offers a compact course to users of the SINAMICS G110 system. Due to the uniform parameterization and commissioning of MICROMASTER 4 and SINAMICS G110, both technologies can be combined easily in a single course. A training course on the subject of service and commissioning provides the necessary depth of technical knowledge for SINAMICS G120 and SINAMICS G120D. SINAMICS G120 is also covered by various courses which deal more generally with the SINAMICS drive system. All courses contain as many practical exercises as possible in order to enable intensive and direct training on the drive system and with the tools in small groups. More information on course contents, dates and prices is available on the Internet at: http://www.siemens.com/sitrain

Title

Target group Decisionmakers, sales personnel Project managers, project personnel Programmers Commissioning engineers, configuring engineers, service personnel Maintenance personnel

Duration

Course code

SINAMICS system overview MICROMASTER MM4/ SINAMICS G110 compact course SINAMICS G120 service and commissioning SINAMICS communication

2 days 1 day

DR-SN-UEB SD-WSMM4

2 days 5 days

DR-G120-EXP DR-SN-COM

Siemens D 11.1 2009

8/3

Siemens AG 2009

SINAMICS G110, SINAMICS G120


Services and documentation
SINAMICS G110 training case SINAMICS G120 training case

Overview

Applications

A training case is available for on-site training and demonstration of the SINAMICS G120 system. It can demonstrate and increase the understanding of a wide range of SINAMICS G120 functions. The case uses the CU240S DP-F or CU240S PN-F as a Control Unit with which the PROFIBUS or PROFINET interface and safety functions can be demonstrated. The modular SIDEMO case system for micro-systems also includes a training case for SINAMICS G110 which is designed for mobile use for sales and service. The training case is equipped with an analog version of a SINAMICS G110 inverter. The training case can be operated on its own or together with training systems such as LOGO!, SIMATIC S7-200, and SITOP DC-UPS. For this reason, a conversion guide is enclosed with the training case that allows the inverter to be replaced by a USS version (not included in the scope of supply). The training systems are fitted in dark blue transport cases 400 300 210 mm (gross weight 12 kg). The transport cases can be stacked. Additional information is available on the Internet under http://www.siemens.com/sidemo

Design
CU240S DP-F Control Unit or CU240S PN-F Control Unit PM240 Power Module, frame size FSA, 0.37 kW (0.5 hp) Basic Operator Panel (BOP) Induction motor 1LA Encoder Load equipment (dynamometer) Simulator panel Power cable Storage and transport case

Technical specifications
SINAMICS G120 training case Input voltage Degree of protection acc. to DIN VDE 0470 Part 1, EN 60529, IEC 529 Ambient temperature, perm. Storage and transport 20 +60 C 5 40 C 540 mm 500 mm 400 mm 10 kg Operation Dimensions Width Height Depth Weight, approx. 230 V 1 AC IP00

Selection and ordering data


Order No. SINAMICS G110 training case (incl. BOP operator panel) Line supply adapter 110 V/230 V 6AG1064-1AA03-0AA0 6AG1064-1AA02-0AA0

Selection and ordering data


Order No. SINAMICS G120 training case with CU 240S DP-F and Tanos box 6ZB2480-0CD00 with CU 240S DP-F and Peli box Line supply adapter 110 V/230 V 6ZB2480-0CE00 6AG1064-1AA02-0AA0 with CU 240S PN-F and Tanos box 6ZB2480-0CF00

8/4

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Services and documentation
SINAMICS G110 documentation SINAMICS G120 documentation

Overview
The following manuals are available for the standard SINAMICS G110 inverters:
Manuals Operating instructions Parameter list Getting Started Guide multilingual

Overview
SINAMICS G120 is a modular inverter system that comprises different function units these are primarily the Control Unit and the Power Module. The documentation is also organized in a modular structure. The following manuals are available:
Manuals Hardware Installation Manual Operating List instructions Manual Getting Started

Controlled Power Modules


CPM110 de, en, fr, it, es de, en, fr, it, es

Manuals are available in the following forms: SD Manual Collection on DVD All manuals on low-voltage motors, geared motors and low-voltage inverters are on the DVD in several languages. Paper documentation A Getting Started Guide is supplied in hard copy for the Controlled Power Modules. Additionally, the Operating instruction and the Parameter list can be ordered as hard copy. Online version on Internet as download The documentation is also available on the Internet under http://www.siemens.com/sinamics-g110/documentation

Control Units
CU230P-2 CU240S CU240E PM240 PM250 PM260 de, en de, en de, en de, en 1) de, en de, en de, en de, en 2) de, en 2) 3)
3)

de, en, fr, it, es de, en, fr, it, es de, en, fr, it, es multilingual multilingual multilingual

Power Modules

3)

Manuals are available in the following forms: SD Manual Collection on DVD All manuals on low-voltage motors, geared motors and low-voltage inverters are on the DVD in several languages.
Order No. 6SL3298-0AA11-0AP0 6SL3298-0AA11-0BP0 6SL3298-0AA11-0DP0 6SL3298-0AA11-0CP0 6SL3298-0AA11-0EP0 6SL3298-0BA11-0AP0 6SL3298-0BA11-0BP0 6SL3298-0BA11-0DP0 6SL3298-0BA11-0CP0 6SL3298-0BA11-0EP0
2) 3) 1)

Selection and ordering data


Type of documentation SINAMICS G110 Operating instructions (hard copy) Language German English French Italian Spanish SINAMICS G110 Parameter list (hard copy) German English French Italian Spanish

Paper documentation A Getting Started Guide is supplied as hard copy with every Power Module and Control Unit. Online version on Internet as download The documentation is also available on the Internet under http://www.siemens.com/sinamics-g120/documentation

In addition, a Function Manual is available for the CU230P-2 Control Unit. This describes all of the functions between the CU230P-2 and the corresponding Power Modules. A common List Manual is available for the CU240S and CU240E Control Units. The parameter settings for the Power Modules are included in the List Manual for the Control Units.

Additional information
Language de en fr it es Multilingual Manual in language German English French Italian Spanish de, en, fr, it, es

Usage phases: Planning and engineering phase, implementation phase, installation and commissioning phase, application phase, maintenance and service phase. List Manual/Parameter list The List Manual or the Parameter list describes all parameters, function charts, and faults/warnings for the product/system as well as their meanings and setting options. It contains parameter data and fault/warning descriptions with functional correlations. Usage phases: Commissioning of components that have already been connected, engineering plant and system functions and fault cause/diagnostics. Getting Started/Getting Started Guide The Getting Started or Getting Started Guide provides information about getting started for the first-time user as well as references to additional information. It contains information about the basic steps to be taken during commissioning. The information in the other documentation should be carefully observed for all of the other work required. Usage phases: Commissioning components that have already been connected.

Hardware Installation Manual The Hardware Installation Manual describes the procedures that must be undertaken regarding a product so that the product can be used at the required location and in the required way. The Hardware Installation Manual contains all relevant information on setting up, installing, and wiring up and the necessary dimension drawings and wiring/circuit diagrams. Usage phases: Installation and commissioning phase Operating instructions Operating instructions are a comprehensive collection of all information necessary for the normal and safe operation of products, parts of plants and complete complete plants (EN 62079).

Siemens D 11.1 2009

8/5

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Services and documentation
SINAMICS G110D documentation SINAMICS G120D documentation

Overview
SINAMICS G110D is a distributed, compact frequency inverter for single-motor drives in a high degree of protection for basic applications. The following manuals are available:
Manuals Hardware Operating Installation instructions Manual SINAMICS G110D de, en List Manual de, en Getting Started de, en

Overview
SINAMICS G120D is a distributed, modular frequency inverter for single-motor drives in a high degree of protection for demanding applications. The documentation is also organized in a modular structure. The following manuals are available:
Manuals Hardware Installation Manual Operating instructions List Manual Getting Started

Manuals are available in the following forms: SD Manual Collection on DVD All manuals on low-voltage motors, geared motors and low-voltage inverters are on the DVD in several languages. Paper documentation A Getting Started is supplied as hard copy with every SINAMICS G110D distributed inverter. Online version on Internet as download The documentation is also available on the Internet under http://www.siemens.com/sinamics-g110d/documentation

Control Units
CU240D PM250D 2) de, en de, en 3) de, en, fr, it, es 1) de, en, fr, it, es 1)

Power Modules

Manuals are available in the following forms: SD Manual Collection on DVD All manuals on low-voltage motors, geared motors and low-voltage inverters are on the DVD in several languages. Paper documentation A Getting Started is supplied as hard copy with every Power Module and Control Unit. Online version on Internet as download The documentation is also available on the Internet under http://www.siemens.com/sinamics-g120d/documentation

Additional information
Language de en fr it es Multilingual Manual in language German English French Italian Spanish de, en, fr, it, es

List Manual The List Manual describes all parameters, function charts, and faults/warnings for the product/system as well as their meanings and setting options. It contains parameter data and fault/warning descriptions with functional correlations. Usage phases: Commissioning of components that have already been connected, engineering plant and system functions and fault cause/diagnostics. Getting Started

Hardware Installation Manual The Hardware Installation Manual describes the procedures that must be undertaken regarding a product so that the product can be used at the required location and in the required way. The Hardware Installation Manual contains all relevant information on setting up, installing, and wiring up and the necessary dimension drawings and wiring/circuit diagrams. Usage phases: Installation and commissioning phase Operating instructions Operating instructions are a comprehensive collection of all information necessary for the normal and safe operation of products, parts of plants and complete plants (EN 62079). Usage phases: Planning and engineering phase, implementation phase, installation and commissioning phase, application phase, maintenance and service phase.

The Getting Started provides information about getting started for the first-time user as well as references to additional information. It contains information about the basic steps to be taken during commissioning. The information in the other documentation should be carefully observed for all of the other work required. Usage phases: Commissioning components that have already been connected.

1) 2)

A common Getting Started is available for the CU240D Control Units and the PM250D Power Modules. The installation instructions for the PM250D Power Module are included in the Getting Started.

3)

The parameter settings for the Power Modules are included in the List Manual for the Control Units.

8/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Services and documentation
SD Manual Collection

Overview
The SD Manual Collection provides a concise summary of all of the manuals for the low-voltage motors, geared motors and lowvoltage inverters. It is admirably suited for commissioning and service, in the office it replaces the space-consuming collection of catalogs and allows information to be quickly accessed: Keyword search within a PDF file Full-text search in the complete DVD Electronic update service, free of charge for 1 year The DVD can be networked, i.e. the PDFs can be stored on a central server The SD Manual Collection on DVD in several languages (including German, English, French, Italian, Spanish) includes manuals for the following motors and inverters: Low-voltage motors - IEC motors - NEMA motors Geared motors Low-voltage inverters - MICROMASTER 3 - MICROMASTER 4 - SINAMICS G110 - SINAMICS G120, SINAMICS G120D - SIMATIC ET200 converter Update service for 1 year In addition, an update service that includes the supply of the current SD Manual Collection and the three following updates can be ordered. This is valid for one year. If the contract is not cancelled, it is automatically extended by 1 year.

Selection and ordering data


Order No. SD Manual Collection on DVD 1) multilingual All manuals for the low-voltage motors, geared motors and low-voltage inverters SD Manual Collection on DVD 1) multilingual, updated service for 1 year
new

6SL3298-0CA00-0MG0

new

6SL3298-0CA10-0MG0

1)

Subject to export regulations: AL: N and ECCN: 5D992

Siemens D 11.1 2009

8/7

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Services and documentation
My Documentation Manager

Overview
My Documentation Manager is the web-based system to generate personalized documentation based on standard documents. It is part of the Service & Support Portal. You must register for Configure and Generate/Manage (the existing login can be used, e.g. Siemens Mall)

Example: For SINAMICS G120

Opening My Documentation Manager My Documentation Manager opens in two ways Search in the Service & Support Portal http://www.siemens.com/automation/service&support The appropriate manuals are designated by configurable. My Documentation Manager opens by clicking on Display and configure. The selected document is displayed as the current document. Using the direct link from the Service & Support Portal https://www.automation.siemens.com/docconf/ After logon/registration, the online help is displayed as current document. My Documentation Manager offers the following options: Display View, print or download standard documents or personalized documents Configure Transfer standard documents or parts of them to personalized documents Generate/Manage Produce and manage personalized documents in the formats PDF, RTF or XML

8/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Services and documentation
Customer Support

Configuration and Software Engineering


Support in configuring and developing with customer-oriented services from actual configuration to implementation of the automation project. 1)

.I

Service On Site
With Service On Site we offer services for startup and maintenance, essential for ensuring system availability. In Germany 0180 50 50 444 1) ( 0.14 /min. from a German landline network, mobile telephone prices may vary)

In the face of harsh competition you need optimum conditions to keep ahead all the time: A strong starting position. A sophisticated strategy and team for the necessary support - in every phase. Service & Support from Siemens provides this support with a complete range of different services for automation and drives. In every phase: from planning and startup to maintenance and upgrading. Our specialists know when and where to act to keep the productivity and cost-effectiveness of your system running in top form.

Online Support
The comprehensive information system available round the clock via Internet ranging from Product Support and Service & Support services to Support Tools in the Shop. http://www.siemens.com/ automation/service&support

Repairs and Spare Parts


In the operating phase of a machine or automation system we provide a comprehensive repair and spare parts service ensuring the highest degree of operating safety and reliability. In Germany 0180 50 50 448 1) ( 0.14 /min. from a German landline network, mobile telephone prices may vary)

Technical Support
Competent consulting in technical questions covering a wide range of customer-oriented services for all our products and systems. Tel.: +49 (0)180 50 50 222 Fax: +49 (0)180 50 50 223 ( 0.14 /min. from a German landline network, mobile telephone prices may vary) http://www.siemens.com/ automation/support-request

Optimization and Upgrading


To enhance productivity and save costs in your project we offer high-quality services in optimization and upgrading. 1)

SPARESonWeb Online spare parts catalog


SPARESonWeb is a web-based tool for selecting the spare parts available for the SINAMICS system. After you have registered and entered the serial number and order number, the spare parts available for the relevant unit are displayed. The delivery state for specific orders can be displayed for all shipped SINAMICS products. http://workplace.automation. siemens.com/sparesonweb

Technical Consulting
Support in the planning and designing of your project from detailed actual-state analysis, target definition and consulting on product and system questions right to the creation of the automation solution. 1)

1)

For country-specific telephone numbers go to our Internet site at: http://www.siemens.com/automation/service&support

Siemens D 11.1 2009

8/9

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Services and documentation
Notes

8/10

Siemens D 11.1 2009

Siemens AG 2009

Appendix
9/2 9/3 9/5 9/6 9/6 9/8 9/9 9/10 9/11 9/12 9/12 9/12 9/12 9/13 9/15 9/17 9/18

9
SIRIUS M200D Motor starters Frequency inverters for SIMATIC ET 200 distributed I/O Frequency inverters MICROMASTER 410/420/430/440 Low-voltage motors IEC squirrel-cage motors IEC squirrel-cage motors 1LE1/1PC1 generation of motors Customized motors NEMA motors Siemens Contacts Worldwide Information and Ordering in the Internet and on DVD Siemens Industry Automation and Drive Technologies in the WWW Product Selection Using the Offline Mall of Industry Easy Shopping with the Industry Mall Subject index Order number index Conditions of Sale and Delivery Export Regulations

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
SIRIUS M200D Motor starters
For spatially extensive and distributed drive solutions without a control cabinet, it is recommended to use the especially rugged and favorably-priced SIRIUS M200D AS-i Basic motor starters in a high IP65 degree of protection for AS-Interface communication. This motor starter distinguishes itself as a result of its simple commissioning and its level of standardization to other products such as frequency inverters and the ET 200pro distributed I/O system. Quickly mounted, simply parameterized and precisely diagnosed The SIRIUS M200D motor starters can be mounted with just a few manual operations. The integrated connector technology results in a significant reduction of the wiring costs. Motor cables
SIRIUS M200D Main features Available as direct and reversing starter. As electronically and mechanically switching version Fast and fail-safe line supply and motor cable connections using an ISO 23570 plug connector system Rugged and widely established M12 connection system for digital inputs and outputs, as well as for the AS-Interface bus connection Integrated connector monitoring on the infeed side Continuous wiring to the SINAMICS G120D frequency inverters as well as to the SIMATIC ET 200pro distributed I/O system Integrated short-circuit protection Full motor protection using overload protection and temperature sensor (PTC, TC) Low variance only 2 device versions up to 5.5 kW (7.4 hp) as a result of the wide range Simple local parameterization using the integrated DIP switch Simple and user-friendly installation Integrated maintenance switch that can be locked using 3 locks (multi-stage service) TIA integration via the AS-Interface, 2 digital inputs visible in the process image Optionally available integrated manual-local control using a keyswitch Optionally available brake control Extensive diagnostics concept using LEDs and as highlight, also via the AS-Interface bus protocol max. 5.5 KW (7.4 hp) (at 400 V) 0.15 ... 2 A/1.5 ... 12 A (mechanical version) 0.15 ... 2 A/1.5 ... 9 A (electronic version) 2 (mech. motor starters up to 2 A), 1 (all other motor starters) AC-1, AC-2, AC-3, AC-4 Short-circuit and overload protection AS-Interface via M12 Diagnostics via LED, S1 status bit, detailed diagnostics via AS-Interface bus 4, of which 2 via process image 1, permanently assigned to the group fault Optional, with 400 V AC/230 V AC or 180 V DC Optional, with MANUAL AUTO keyswitch, jogging/latching, inhibit Quick Stop IP65 215 mm 295 mm 159 mm

can be directly plugged-in. The motor starters sense the actual current flowing. The evaluation of the current of the parameterizable electronic overload protection increases the availability of the drive system just the same as the reliable signals that are output when setpoints are exceeded or undershot. A drive is locally controlled using the version with integrated manual operation. Extensive device diagnostics is possible on site using the LEDs. In addition to diagnostics using the process image PAE, the device can generate up to 15 different diagnostic messages per slave. The highest priority message can be read-out via the AS-Interface communication. You can obtain additional information under http://www.siemens.com/sirius-motorstarter

Power rating of AC motors Rated operating current at 400 V at 500 V Type of assignment Utilization categories Motor protection Bus connection Diagnostics Digital inputs Digital output Brake Manual-local control

Permissible ambient temperature 25 ... +55 C (in operation), 40 ... +70 C (when stored) Degree of protection Dimensions (H W D)

SIRIUS M200D motor starter, electronic version

SIRIUS M200D motor starter, mechanical version

9/2

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Frequency inverters for SIMATIC ET 200
For the SIMATIC ET 200 distributed I/O system, there are frequency inverters that are available as modules that are completely integrated into the system. Inverters are available for the finely modular SIMATIC ET 200S FC system in IP20 degree of protection, as well as for the cabinetless SIMATIC ET 200pro FC system in IP65 degree of protection. With a wide range of possibilities, the frequency inverters expand the functional scope of the modular modules used in both systems (e.g. inputs and outputs, technology modules, direct starters and soft starters). Using the appropriate interface modules, these can be connected to PROFIBUS and PROFINET via the SIMATIC ET 200 system
SIMATIC ET 200S FC Main features A frequency inverter is completely embedded in a distributed I/O system with degree of protection IP20 Extremely simple installation and low probability of errors due to the self-establishing power and communication bus Space-saving design as a result of compact dimensions and common protection When service is required, the frequency inverter can be quickly replaced without the need for tools (hot swapping) Frequency control (V/f), vector control with and without encoder Line-commutated energy recovery using the latest generation of power electronics Modular design with Control Unit (control module) and Power Module (power unit) Frequency inverter version with integrated, autonomous, fail-safe functions without any complex external circuitry 0.75 kW (1.0 hp) 2.2 kW (3.0 hp) 4.0 kW (5.4 hp) 380 ... 480 V 3 AC +10 % 10 % Control Unit + Power Module up to 0.75 kW (1.0 hp): 80 mm, otherwise 145 mm 47 63 Hz Overload current 1.5 rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s Overload current 2 rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s 0 650 Hz 8 kHz (standard), 2 16 kHz (in steps of 2 kHz) 1, parameterizable 96 % Connection to PROFIBUS via IM151 interface module Connection to PROFINET via IM151-3PN interface module Integration of PLC functionality via IM151-CPU and IM151-7 F-CPU interface modules RS232 interface with USS protocol for commissioning at the PC using the STARTER commissioning software Slot for an optional Micro Memory Card for uploading or downloading parameter settings PTC/KTY84 interface for motor monitoring Speed encoder interface (Sub-D connector) for unipolar HTL incremental encoder Control of the integrated safety functions via PROFIsafe (using the Power Module PM-D F PROFIsafe) or terminals (using the Safety Local Power Module PM-D F X1) UL, cUL ,CE and c-tick, Low-Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC Control module with integrated safety functions according to Category 3 of EN 954-1 and according to SIL 2 of IEC 61508: Safe Torque Off (STO) Safely Limited Speed (SLS) Safe Stop 1 (SS1) The safety functions Safely Limited Speed and Safe Stop 1 are not permitted for pulling loads such as e.g. lifting gear and winders IP20

bus and PLC functionality can be integrated into the system. Fail-safe frequency inverter functions can either be controlled locally or via PROFIsafe. An overview of the features of these frequency inverters is shown in the following tables. You will find the complete product spectrum with ordering data, technical specifications and descriptions in Catalog IK PI Industrial Communication for Automation and Drives and on the Internet under http://www.siemens.com/et200s-fc/documentation and http://www.siemens.com/et200pro-fc/documentation

Rated powers

Input voltage Overall width Line supply frequency Overload capability Output frequency Pulse frequency Skippable frequency range Efficiency Interfaces

Standards conformance Functional safety

Degree of protection

SIMATIC ET 200S FC Control Units

SIMATIC ET 200S FC Power Modules

Siemens D 11.1 2009

9/3

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Frequency inverters for SIMATIC ET 200
SIMATIC ET 200pro FC Main features A frequency inverter is completely embedded in a distributed I/O system with IP65 degree of protection Extremely simple installation and low probability of errors due to the self-establishing power and communication bus The frequency inverter can be quickly replaced when service is required without interrupting bus communications to other modules within SIMATIC ET 200pro FC Frequency control (V/f), vector control without encoder Line-commutated energy recovery using the latest generation of power electronics Frequency inverter version with integrated, autonomous, fail-safe functions without any complex external circuitry. 1.1 kW (1.5 hp) (at 0 55 C ambient temperature) 1.5 kW (2.0 hp) (at 0 45 C ambient temperature) 380 ... 480 V 3 AC +10 % 10 % 155 mm 47 63 Hz Overload current 1.5 rated output current (i.e. 150 % overload capability) for 60 s, cycle time 300 s Overload current 2 rated output current (i.e. 200 % overload capability) for 3 s, cycle time 300 s 0 650 Hz 4 kHz (standard) 2 16 kHz (in steps of 2 kHz) 1, parameterizable 96 % Connection to PROFIBUS via IM154-1 and IM154-2 interface modules Available soon: Connection to PROFINET via IM154-4PN interface module and connection to IM154-8 CPU interface module Optical interface with USS protocol for optical RS232 connecting cable Control for an electro-mechanical motor brake 180 V DC Slot for an optional memory card (MMC) to upload or download parameter settings PTC/KTY84 interface for motor temperature monitoring Control of the integrated safety functions via the Safety Local maintenance switch module F RSM or via F-Switch PROFIsafe UL, cUL, CE, Low-Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC Version with integrated safety functions according to Category 3 of EN 954-1 and according to SIL 2 of IEC 61508: Safe Torque Off (STO) Safely Limited Speed (SLS) Safe Stop 1 (SS1) The safety functions Safely Limited Speed and Safe Stop 1 are not permitted for pulling loads such as e.g. lifting gear and winders IP65

Rated powers Input voltage Overall width Line supply frequency Overload capability Output frequency Pulse frequency Skippable frequency range Efficiency Interfaces

Standards conformance Functional safety

Degree of protection

SIMATIC ET 200pro FC Standard frequency converter

SIMATIC ET 200pro FC Fail-safe Frequency converter with integrated safety functions

9/4

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Frequency inverters MICROMASTER 410/420/430/440
MICROMASTER inverters from Siemens perfectly complement the motors. The table shows an overview of the features of these inverters. For the full range of products complete with ordering data, technical details and information, see Catalog DA 51.2.
MICROMASTER 410 Main features The low-price solution for variable speeds with 3-phase motors connected to 1-phase line supplies, e.g. for pumps, fans, billboards, barriers, gate drives and automated machines Discontinued product 1) 100 ... 120 V 1 AC 200 ... 240 V 1 AC MICROMASTER 420 The universal inverter for 3-phase line supplies and optional fieldbus connection, e.g. for conveyor belts, material transport, pumps, fans and processing machines

For up-to-date information on MICROMASTER 420/430/440 frequency inverters, visit the Internet at http://www.siemens.com/micromaster/documentation
MICROMASTER 430 The specialist for pumps and fans with optimized OP (manual/ automatic changeover), adapted software functionality and optimized power yield MICROMASTER 440 The all-rounder with sophisticated vector control (with and without encoder feedback) for a wide range of applications in sectors such as conveyor systems, textiles, elevators, hoisting gear and machinery construction 0.12 ... 250 kW (0.16 ... 335 hp) 200 ... 240 V 1 AC 200 ... 240 V 3 AC 380 ... 480 V 3 AC 500 ... 600 V 3 AC

Power range Voltage ranges

0.12 ... 0.75 kW (0.16 ... 1.0 hp) 0.12 ... 11 kW (0.16 ... 15 hp) 200 ... 240 V 1 AC 200 ... 240 V 3 AC 380 ... 480 V 3 AC

7.5 ... 250 kW (10 ... 335 hp) 380 ... 480 V 3 AC

Closed-loop control V/f characteristic V/f characteristic V/f characteristic V/f characteristic Multipoint characteristic Multipoint characteristic Multipoint characteristic Multipoint characteristic (parameterizable V/f charac- (parameterizable V/f charac- (parameterizable V/f charac- (parameterizable V/f characteristic) teristic) teristic) teristic) FCC (Flux Current Control) FCC (Flux Current Control) FCC (Flux Current Control) FCC (Flux Current Control) Vector control Process control Inputs 3 Digital inputs 1 Analog input 1 Relay output The PLC partner for LOGO! and SIMATIC S7-200 Internal PI controller 3 Digital inputs 1 Analog input 1 Analog output 1 Relay output The ideal partner for your automation tasks, whether with SIMATIC S7-200, SIMATIC S7300/400 (TIA) or SIMOTION BICO technology Compound braking for controlled rapid braking Internal PID controller 6 Digital inputs 2 Analog inputs 1 PTC/KTY input 2 Analog outputs 3 Relay outputs The ideal partner for your automation tasks, whether with SIMATIC S7-200, SIMATIC S7300/400 (TIA) or SIMOTION Energy-saving mode Load torque monitoring (detects dry-running pumps) Motor staging Bypass mode BICO technology Internal PID controller (autotuning) 6 Digital inputs 2 Analog inputs 1 PTC/KTY input 2 Analog outputs 3 Relay outputs The ideal partner for your automation tasks, whether with SIMATIC S7-200, SIMATIC S7300/400 (TIA) or SIMOTION 3 switchable drive data sets Integrated brake chopper (up to 75 kW) Torque control BICO technology

Outputs Interfacing to the automation system

Additional features

Natural cooling (no fan unit) Position of connections the same as for conventional switching elements (e.g. contactors) Version with flat heat sink

Examples of MICROMASTER 410/420/430/440

1)

Can only be ordered as spare part.

Siemens D 11.1 2009

9/5

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
IEC squirrel-cage motors
With a power range from 0.06 kW to 1250 kW (0.08 hp to 1676 hp), low-voltage motors are available for the widest range of requirements and applications that are harmonized and coordinated with the MICROMASTER and SINAMICS frequency inverters. In addition to energy-saving motors and explosionproof motors, there are also sector and customer-specific motors
IEC squirrel-cage motors Versions Rated power Frame sizes Type of construction Speed Rated torque Rated voltages Energy-saving motors Aluminum frame 0.06 ... 45 kW (0.08 ... 60 hp) 56 M ... 225 All common types of construction 750 ... 3000 rpm 0.3 ... 292 Nm All commonly used voltages Cast iron frame 0.75 ... 1250 kW (0.1 ... 1676 hp) 100 L ... 450 All common types of construction 750 ... 3000 rpm 9.9 ... 10300 Nm All commonly used voltages Temp. time classes F200/F300/F400 0.37 ... 200 kW (0.5 ... 268 hp) 80 M ... 315 L All common types of construction 1000 ... 3000 rpm 2.5 ... 1546 Nm 230 V/400 VY, 500 V, 400 V/690 VY, 500 VY EFF1, EFF2 IP55 Aluminum, cast iron Surface-cooled 155 (F) utilized to 130 (B) CE no no

such as smoke extraction motors. The table shows an overview of the technical features of these motors. The available product range with ordering data, technical specifications and detailed information is provided in Catalog D 81.1 IEC Squirrel-Cage Motors frame sizes 56 to 450 and on the Internet under: http://www.siemens.com/motors/documentation

Marking Degree of protection Frame Type of cooling Temperature class Standards and approvals Approvals for marine drives Explosion protection (incl. temp. class)

EFF1, EFF2 IP55 Aluminum Surface-cooled 155 (F) utilized to 130 (B) / 155 (F) CE, CCC, UL, CSA Below-deck applications: BV, DNV, GL, LR Ex nA II T3 (Zone 2), Dust ex (Zone 21, 22)

EFF1, EFF2 IP55 Cast iron Surface-cooled 155 (F) utilized to 130 (B) / 155 (F) CE, CCC, UL, CSA Below-deck applications: BV, DNV, GL, LR Ex nA II T3 (Zone 2), Dust ex (Zone 21, 22)

9
Examples of energy-saving motors Example of smoke extraction motors

9/6

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
IEC squirrel-cage motors
IEC squirrel-cage motors Versions Rated power Frame sizes Type of construction Speed Rated torque Rated voltages Marking Degree of protection Frame Type of cooling Temperature class Explosion-proof motors Type of protection e 0.12 ... 165 kW (0.16 ... 221.3 hp) 63 M ... 315 L All common types of construction 1000 ... 3000 rpm 0.61 ... 1300 Nm All commonly used voltages See Catalog D 81.1 IP55, IP56 (non-heavy-sea), IP65 FS 63 ... 160 L aluminum FS 100 L ... 315 L cast iron Surface-cooled 155 (F) utilized to 130 (B) / 155 (F) Type of protection de/de Type of protection n 0.25 ... 132 kW (0.34 ... 177 hp) 71 M ... 315 M All common types of construction 750 ... 3000 rpm 1 ... 970 Nm All commonly used voltages See Catalog D 81.1 IP55, IP56 (non-heavy-sea), IP65 FS 71 M ... 315 M cast iron Surface-cooled 155 (F) utilized to 130 (B) (line operation) 155 (F) utilized to 155 (F) (inverter operation) 0.09 ... 1000 kW (0.12 ... 1341 hp) 63 M ... 450 All common types of construction 750 ... 3000 rpm 1 ... 8090 Nm All commonly used voltages Analog energy-saving motors EFF1/EFF2 IP55, IP56 (non-heavy-sea), IP65 FS 63M ... 160 L aluminum FS 100 L ... 450 cast iron Surface-cooled 155 (F) utilized to 130 (B) Dust explosion protection 0.06 ... 1000 kW (0.08 ... 1341 hp) Zone 21: 56 M ... 315 L Zone 22: 56 M ... 450 All common types of construction 750 ... 3000 rpm 0.3 ... 8090 Nm All commonly used voltages Analog energy-saving motors EFF1/EFF2 Zone 21: IP65 Zone 22: IP55 FS 63 M ... 225 M aluminum FS 100 L ... 450 cast iron Surface-cooled 155 (F) utilized to 130 (B)

Standards and approvals Approvals for marine drives Explosion protection (incl. temp. class)

CE, CCC, GOST, ATEX Below-deck applications: BV, DNV, GL, LR II 2G Ex e II T1-T3

CE, CCC, GOST, ATEX, NEPSI CE, CCC, GOST, ATEX, NEPSI CE, CCC, GOST, ATEX Below-deck applications: BV, DNV, GL, LR II 2G Ex de IIC T1-T4 Below-deck applications: BV, DNV, GL, LR II 3G Ex nA II T3 Below-deck applications: BV, DNV, GL, LR Zone 21: II 2D Ex tD A21 IP65 T125 C Zone 22: II 3D Ex tD A22 IP55 T125 C

9
Examples of explosion-proof motors

Siemens D 11.1 2009

9/7

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
IEC squirrel-cage motors 1LE1/1PC1 generation of motors
Increasing energy costs have resulted in greater emphasis on the power consumption of drive systems. It is extremely important to utilize the full potential to minimize energy consumption here to secure competitiveness today and in the future. This is the reason that already today, Siemens is developing a new generation of low-voltage motors. Innovative copper rotors create the best requisites for motors with high efficiencies. The new motors for EFF1 (High Efficiency) offer considerable energy savings
Versions

and protect our environment. The table shows an overview of the technical features of these motors. The presently available product range with ordering data, technical specifications and detailed information is listed in Catalog D 81.1 Low-Voltage Motors IEC Squirrel-Cage Motors frame sizes 56 to 450 and on the Internet under: http://www.siemens.com/motors/documentation

IEC squirrel-cage motors 1LE1/1PC1 generation of motors Self-cooled 1LE1 energy-saving motors with: Improved efficiency (EFF2) High efficiency (EFF1) Self-cooled 1LE1 motors with increased power and: Improved efficiency (EFF2) High efficiency (EFF1) Forced-air-cooled 1LE1 motors without external fan and fan cover with: Improved efficiency (EFF2) High efficiency (EFF1) Naturally cooled 1PC1 motors without external fan and fan cover with: Improved efficiency (EFF2) High efficiency (EFF1) 0.75 ... 22 kW (1 ... 30 hp) (1LE1 motor series) 0.3 ... 9 kW (0.4 ... 12 hp) (1PC1 motor series) 100 L to 160 L Without flange: IM B3, IM B6, IM B7, IM B8, IM V5 without canopy, IM V6, IM V5 with canopy With flange: IM B5, IM V1 without canopy, IM V1 with canopy, IM V3, IM B35 With standard flange: IM B14, IM V19, IM V18 without canopy, IM V18 with canopy, IM B34 750 ... 3000 rpm 9.9 ... 150 Nm (1LE1 motor series) 4.05 ... 60 Nm (1PC1 motor series) All commonly used voltages EU/CEMEP efficiency classification: EFF1: 2-, 4-pole, EFF2: 2-, 4-pole US EPACT legislation: 2-, 4-, 6-pole IP55 as standard Aluminum Self-ventilated (1LE1 motor series): Frame size 100 L to 160 L (IC 411) Forced-air cooled (1LE1 motor series): Frame size 100 L to 160 L (IC 416) Naturally cooled (1PC1 motor series): Frame size 100 L to 160 L (IC 410) Temperature class 155 (F), utilized to temperature class 130 (B) CE

Rated power Frame sizes Type of construction

Speed Rated torque Rated voltages Marking Degree of protection Frame Type of cooling

Temperature class

Standards and approvals

Examples of IEC squirrel-cage motors new 1LE1 generation, aluminum frame

9/8

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Customized motors
In addition to the products offered in the catalog, our range of motors also includes Customized motors. We can develop individual drive solutions for your special requirements, provide samples and supply them in accordance with your logistical requirements. Our worldwide network of Siemens offices as well as our regional offices in Germany are, of course, available to provide advice (see Siemens Contacts Worldwide). Please inquire for details. We have listed below some of the Customized solutions that have been already implemented: High-speed motors for textile machines and compressors Motors with increased power density Liquid-cooled motors Synchronous generators for standby supply systems Motors for wood processing plants Built-in motors for refrigerating motors/compressors (freezer proof) Rolling motors for harsh conditions (e.g. roller drives) Pump motors with special shafts/special materials Single-phase motors for industrial applications Lifting gear motors

Built-in motor for refrigeration

Pump motor with special shaft/special materials

Roller motor for harsh conditions

Hoisting gear motor

Siemens D 11.1 2009

9/9

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
NEMA motors
We manufacture low-voltage motors in accordance with the NEMA standard for a wide range of different application areas to fulfill NAFTA market specifications (USA, Canada, Mexico). These include motors designed in conformance with the US EPACT legislation (specified minimum efficiency levels) up to motors with NEMA premium efficiency levels: Our NEMA motor series provide the highest operating reliability and maximum service life. Designed and manufactured for rugged operation,
Frame size Power range Number of poles Voltages Frequency Type of construction Frame Type of cooling Temperature class Type spectrum NEMA frame size 56 ... 449 0.25 ... 500 HP 2/4/6/8 230/460/575 V 3 AC 60 Hz, 50 Hz on request Foot-mounted, D flange, C flange, P flange Cast iron, aluminum or steel depending on the version Surface-cooling or internal ventilation depending on the version Temperature class 155 (F), utilized to temperature class 130 (B) General purpose motors Legally specified minimum efficiency levels or NEMA premium efficiency levels Standard motors for general industrial use Aluminum or cast iron frame depending on the version Severe duty motors Legally specified minimum efficiency levels or NEMA premium efficiency levels Cast iron frame Motors for use under extremely difficult environmental conditions Severe duty IEEE841 motors Efficiency levels specified by IEEE that exceed the EPACT legislation Motors with increased requirements for use in the petrochemical industry (according to IEEE841) Cast iron frame Explosion-proof motors Efficiency levels better than or equal to EPACT Multi-label according to Division 1, Class I, Group D and Class II, Groups F&G Single label according to Division 1, Class I, Groups C&D

our NEMA motors withstand even the harshest of industrial conditions strictly in accordance with the ISO 9001 international quality standard; with maximum performance, reliability and efficiency. You will find the complete product spectrum with ordering data, technical specifications and information in Catalog D 81.2 U.S./Canada on the Internet at http://www.sea.siemens.com/motors/documentation

NEMA motors (NEMA = National Electrical Manufacturers Association)

Example of a NEMA motor, Severe Duty SD100, cast iron frame

Example of a NEMA motor, General Purpose GP10A, aluminum frame

9/10

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Siemens Contacts Worldwide
At http://www.siemens.com/automation/partner you can find details of Siemens contact partners worldwide responsible for particular technologies. You can obtain in most cases a contact partner for Technical Support, Spare parts/repairs, Service, Training Sales or Consultation/engineering. You start by selecting a Country, Product or Sector. By further specifying the remaining criteria you will find exactly the right contact partner with his/her respective expertise.

Siemens D 11.1 2009

9/11

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Information and Ordering in the Internet and on DVD

Siemens Industry Automation and Drive Technologies in the WWW


A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. Siemens Industry Automation and Drive Technologies has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address http://www.siemens.com/automation you will find everything you need to know about products, systems and services.

Product Selection Using the Offline Mall of Industry


Detailed information together with convenient interactive functions: The Offline Mall CA 01 covers more than 80,000 products and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the Offline Mall CA 01 can be found in the Internet under http://www.siemens.com/automation/ca01 or on DVD.

Easy Shopping with the Industry Mall


The Industry Mall is the virtual department store of Siemens AG in the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the Industry Mall on the Internet under: http://www.siemens.com/automation/mall

9/12

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Subject index
Chapter/Page A Accessories SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D Adapter for mounting on DIN rail SINAMICS G110 SINAMICS G120 Additional EMC filter, class B Applications SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D Application example B Basic Operator Panel (BOP) SINAMICS G110 SINAMICS G120 Benefits SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D Block diagrams for SINAMICS G110 Brake Relay Braking Module Braking resistors SINAMICS G110D SINAMICS G120 C Card holder for MMC/SD memory card Characteristic curves (derating data) SINAMICS G110 SINAMICS G110D SINAMICS G120 PM240 SINAMICS G120 PM250 SINAMICS G120 PM260 SINAMICS G120D PM250D Circuit breaker Circuit diagrams for SINAMICS G110 Compact inverters SINAMICS G120 Configuration SINAMICS G110D SINAMICS G120 SINAMICS G120D Configuration tools Conformance for SINAMICS G110 Connecting cables SINAMICS G110D SINAMICS G120D Connecting cable SINAMICS G110D SINAMICS G120D Connection diagram CU230 CU240 PM240 PM250 PM260 PM250D Controlled Power Modules SINAMICS G110 CM240NE chemical industry module Customer Support CU230 Control Units CU240 Control Units CU240D Control Units D DC link components SINAMICS G110D SINAMICS G120 Derating data SINAMICS G110 SINAMICS G110D SINAMICS G120 PM240 SINAMICS G120 PM250 SINAMICS G120 PM260 SINAMICS G120D PM250D Design SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D Design information for SINAMICS G120 Dimensional Collection Dimensional drawings SINAMICS G110 SINAMICS G110D SINAMICS G120 PM240 SINAMICS G120 PM250 SINAMICS G120 PM260 SINAMICS G120D PM250D Documentation SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D Door Mounting Kit (IOP) for SINAMICS G120 Drive ES Drive ES engineering system E Efficient Infeed Technology SINAMICS G120 SINAMICS G120D Electromagnetic compatibility EMC filter class B SINAMICS G110 Example F Frequency inverters for SIMATIC ET 200 distributed I/O Frequency inverters MICROMASTER Function SINAMICS G110 Fuses SINAMICS G120 SINAMICS G110D G Group protection SINAMICS G110D SINAMICS G120D H Handheld (IOP) SINAMICS G110D SINAMICS G120 SINAMICS G120D Highlights I Individual protection SINAMICS G110D SINAMICS G120D Infeed concepts Integration SINAMICS G110D SINAMICS G120 CU230 SINAMICS G120 CU240 SINAMICS G120 PM240 SINAMICS G120 PM250 SINAMICS G120 PM260 SINAMICS G120D CU240D SINAMICS G120D PM250D Integrated EMC filter SINAMICS G110 Chapter/Page

3/9 5/15 4/74 6/21 3/9 4/111

5/14 4/83 3/6 5/10 4/42 4/59 4/71 6/18 3/3 5/4 4/4 6/4, 6/8

3/13
3/3 5/2 4/4 6/4

2/11

4/7 8/7
3/10 5/11 4/44 4/60 4/72 6/19

3/9 4/104 3/2 5/3 4/4 6/3

3/11 4/109 4/86


5/14 4/83

5/17
3/6 5/10 4/42 4/59 4/71 6/18

8/5 8/6 8/5 8/6 4/103 7/7 7/7

4/3, 4/50, 4/64 6/3

3/8
3/13

3/14, 4/82, 5/13, 6/20 3/11 4/73


5/6 4/9 6/5

2/11 9/3 9/5


3/3

7 3/7
5/18 6/24 5/18 6/23, 6/24 4/14 4/22 4/32 4/52 4/66 6/14 3/4

3/14 5/13

5/13 6/20

5/15 4/102 6/21

4/106, 4/107 8/9 4/12 4/19 6/7

5/13 6/20

2/10
5/5 4/16 4/22 4/32 4/52 4/66 6/9 6/14 3/13

Siemens D 11.1 2009

9/13

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Subject index
Chapter/Page Intelligent Operator Panel IOP SINAMICS G110D SINAMICS G120 SINAMICS G120D IOP Handheld SINAMICS G110D SINAMICS G120 SINAMICS G120D IOP Door Mounting Kit for SINAMICS G120 K Keyswitch L Line components SINAMICS G110D SINAMICS G120 SINAMICS G120D Line filters for SINAMICS G120 Line reactors SINAMICS G110 SINAMICS G120 Line-side power components SINAMICS G110 SINAMICS G120 Low-voltage motors Load-side power components SINAMICS G120 M Manual-local control Memory card for Control Units MMC memory card MMC memory card Motor cables SINAMICS G110D SINAMICS G120D My Documentation Manager O Output reactors SINAMICS G120 Overview SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D P PC Inverter Connection Kit SINAMICS G110 SINAMICS G120 Plug-in cable SIMATIC DP Power components, load side SINAMICS G120 Power components, line side SINAMICS G110 SINAMICS G120 Power distribution SINAMICS G110D SINAMICS G120D Power Modules PM240 PM250 PM260 PM250D PROFIsafe R Recommended line components SINAMICS G110D SINAMICS G120 SINAMICS G120D Replacement connector SINAMICS G120 Replacement door SINAMICS G120, frame size FSGX Replacement fan SINAMICS G110D SINAMICS G120 SINAMICS G120D
5/15 4/102 6/21 5/15 4/102 6/21

Chapter/Page RS232 interface cable SINAMICS G110D SINAMICS G120 SINAMICS G120D S Safe Brake Control (SBC) Safe Brake Relay Safely Limited Speed (SLS) Safe Stop 1 (SS1) Safe Torque Off (STO) Safety Integrated SINAMICS G120D SD Configurator SD Manual Collection Selection guide, SD Configurator Selection and ordering data SINAMICS G110 SINAMICS G110D SINAMICS G120 CU230 SINAMICS G120 CU240 SINAMICS G120 PM240 SINAMICS G120 PM250 SINAMICS G120 PM260 SINAMICS G120D CU240D SINAMICS G120D PM250D Services and documentation Shield connection kit for SINAMICS G120 SIMATIC ET 200 frequency converters SINAMICS infeed concepts SinaSave SinaSave energy-saving system Sine-wave filter SIRIUS M200D Motor starters SIRIUS M200D Motor starters SIZER SIZER configuration tool Solution Partner Spare Parts Kit SINAMICS G110D SINAMICS G120 SINAMICS G120D Standards conformance for SINAMICS G110 STARTER STARTER commissioning tool Starter Kit SINAMICS G110 Supplementary kit for the chemical industry module Supplementary system components SINAMICS G110D SINAMICS G120 SINAMICS G120D T Technical specifications SINAMICS G110 SINAMICS G110D SINAMICS G120 SINAMICS G120D Terminal Cover Kit Tools and configuration Totally Integrated Automation Training Training case SINAMICS G110 SINAMICS G120 U UL listing USB interface cable SINAMICS G110D SINAMICS G120D
5/15, 5/17 4/103 6/21, 6/22

4/103 5/16

2/4 4/110 2/4 2/3 2/3 6/3 7/2 8/7 7/2


3/4 5/3 4/12 4/19 4/31 4/51 4/65 6/7 6/13

5/13 4/81 6/20

4/74
3/13 4/77 3/13 4/74

9/6
4/88

5/16 4/105 4/105, 5/16, 6/22 4/105, 5/16, 6/22


5/19 6/24

8/8

4/88 3/2 5/2 4/2 6/2

8 4/111, 4/112 9/3 2/10 7/8 7/8 4/95 9/2 9/2 7/4 7/4 5/19, 6/25
5/20

3/9, 7/6 4/108, 7/6

4/113 6/26 3/7 3/9, 5/17, 6/22, 7/5 3/9, 5/17, 6/22, 7/5 3/12 4/106

7/6
4/88 3/13 4/74 5/19 6/25 4/30 4/50 4/64 6/13

5/15 4/102 6/21

3/5 5/6 4/10, 4/17, 4/28, 4/36, 4/55, 4/68 6/6, 6/11, 6/15

2/5

4/114 7 0/4 8/2


8/4 8/4

5/13 4/81 6/20 4/115

3/7, 4/11, 5/6, 6/6 5/17, 7/6 6/22, 7/6

4/113
5/20 4/116

6/26

9/14

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Order number index
Chapter/Page 3NA 3NA3... 3NE 3NE1... 3RK 3RK1901-1NR2. 3RK1911-0DB.. 3RK1911-2BE.. 3RK1922-2BP00 3RV 3RV10 3RX 3RX8000-1CE52-1A.. 3VL 3VL 6AG 6AG1064-1AA02-0AA0 6AG1064-1AA03-0AA0 6ES 6ES7194-1AB01-0XA0 Fuse 3/14, 4/81, 4/82, 5/13, 6/20 4/81, 4/82 6SL3000-1BE3... AS-Interface M12 branch for SINAMICS G110D Connecting cable for distributed inverters Connector set to supply distributed inverters with power RS232 interface cable 5/18 5/18, 6/24 5/18, 6/24 4/103, 5/15, 5/17, 6/21, 6/22 3/14, 4/81, 4/82, 5/13, 6/20 5/18, 6/23 6SL3000-2BE3... 6SL3200-2CE3 6SL3070-0AA00-0AG0 6SL3072-0AA00-0AG0 6SL 6SL3000-0BE3... 6SL3000-0CE3... Fuse Line filter, class A for SINAMICS G120 Line reactor for SINAMICS G120 Braking resistor for SINAMICS G120 Output reactor for SINAMICS G120 Sine-wave filter for SINAMICS G120 SIZER configuration tool for SINAMICS and MICROMASTER STARTER commissioning tool for SINAMICS and MICROMASTER Starter Kit SINAMICS G110 Replacement fan for SINAMICS G120 CU240 Spare Parts Kit for SINAMICS G120 Replacement door for SINAMICS G120, frame size FSGX Terminal Cover Kit for SINAMICS G120 Terminal Cover Kit for SINAMICS G120 Replacement connector for PM260 Power Modules Braking resistor for SINAMICS G120 Output reactor for SINAMICS G120 Sine-wave filter for SINAMICS G120 Line filters for SINAMICS G120 Line reactors for SINAMICS G120 SINAMICS G110 Standard inverters SINAMICS G120 Compact inverters SINAMICS G120 PM240 Power Module SINAMICS G120 PM240 Power Module SINAMICS G120 PM250 Power Module SINAMICS G120 PM260 Power Module SINAMICS G120 CU230P-2 Control Unit SINAMICS G120 CU240 Control Unit Brake Relay for SINAMICS G120 Safe Brake Relay for SINAMICS G120 MMC memory card Chapter/Page 4/74 4/78 4/83 4/88 4/95 7/4 3/9, 5/17, 6/22, 7/5 3/12 4/116 4/113 4/113 4/114 4/114 4/115 4/83 4/88 4/95 4/74 4/78 3/4 4/73 4/31 4/31 4/51 4/65 4/12 4/19 4/109 4/110 4/105, 5/16, 6/22

Circuit breaker

6SL3200-0AB10-0AA0 6SL3200-0SF 6SL3200-0SK00-0AA0 6SL3200-0SM10-0AA0

M12 plug-in cable for distributed inverters Circuit breaker Power supply adapter Training case SINAMICS G110 Connector set for motor cables for distributed inverters SIMATIC DP plug-in cable Connecting cable PROFINET IE M12 Plug PRO for SINAMICS G120D PROFIBUS M12connector for SINAMICS G120D Connector to supply the Control Unit with power 7/8'' connector for SINAMICS G120D Line filter, class A for SINAMICS G120 Line filter, class B for SINAMICS G120 Filter, class B with low leakage currents for SINAMICS G110 Additional EMC filter, class B for SINAMICS G110 Line reactor Output reactor for SINAMICS G120 Braking resistor for SINAMICS G120

4/81, 4/82 8/4 8/4

6SL3200-0SM11-0AA0 5/19, 6/24 6SL3200-0SM12-0AA0 6SL3200-0ST04-0AA1 7/6 6SL3201-0BE12-0AA0 6/23 6SL3202-0ACA0 6SL3202-0AESA0 6/23 6SL3203-0B 6/23 6SL3203-0C 6SL3211-0 6SL3214-3AE 4/74 4/74 3/14 6SL3224-0BE 6SL3224-0XE 6SL3225-0BE 6SL3225-0BH 6SL3243-0BA30-1 3/14, 4/78 4/88 4/83 6SL3244-0BA 6SL3252-0BB00-0AA0 6SL3252-0BB01-0AA0 6SL3254-0AM00-0AA0

6ES7901-4BD00-0XA0 6GK 6GK1901-0DB10-6AA.

6GK1905-0E...

6GK1905-0F...

6SE 6SE6400-2FA00-6AD0 6SE6400-2FB00-6AD0 6SE6400-2FL0

6SE6400-2FS0 6SE6400-3CC 6SE6400-3TC 6SE6400-4BD

3/14

Siemens D 11.1 2009

9/15

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Order number index
Chapter/Page 6SL (continued) 6SL3255-0AA00-2AA1 6SL3255-0AA00-2CA0 6SL3255-0AA00-4BA1 6SL3255-0AA00-4HA0 6SL3255-0AA00-4JA0 6SL3255-0BT01-0PA0 6SL3256-0AP00-0JA0 6SL3260-4TA00-1AA6 6SL3261-1B 6SL3262-1A PC Inverter Connection Kit PC Inverter Connection Basic Operator Panel BOP IOP Handheld Intelligent Operator Panel IOP for SINAMICS G120 CM240NE chemical industry module IOP Door Mounting Kit for SINAMICS G120 Supplementary kit for the chemical industry module Adapter for mounting on DIN rail for SINAMICS G110 Shield Connection Kit for SINAMICS G120 PM240/PM250 Power Modules Adapter for mounting on DIN rail for SINAMICS G120 Shield Connection Kit for SINAMICS G120 PM260 Power Modules Adapter for SINAMICS G110D Shield Connection Kit for SINAMICS G120 Shield Connection Kit 1 for SINAMICS G120 Documentation for SINAMICS G110 Documentation for SINAMICS G110 SD Manual Collection on DVD Braking Module for SINAMICS G120D Replacement fan for SINAMICS G120 Replacement fan for SINAMICS G120D Replacement fan for SINAMICS G110D Spare Parts Kit for SINAMICS G120D Control Units Spare Parts Kit for SINAMICS G110D Control Units Braking resistor for SINAMICS G110D Distributed inverters, SINAMICS G110D Power Modules SINAMICS G120D Control Units SINAMICS G120D USB interface cable for distributed inverters Manual-local control with keyswitch for SINAMICS G110D Card holder or MMC/SD memory card for SINAMICS G110D 3/9, 4/108, 7/6 4/108 3/9, 4/104 4/103, 5/15, 6/21 4/103 4/106 4/103 4/106 3/9 4/111 6XV1870-8A 6SW 6SW1700- 6XV 6XV1822-5B... Engineering program Drive ES Connecting cable to supply the Control Unit with power 7/8'' plug-in cable for SINAMICS G120D Connecting cable PROFIBUS M12 plug-in cable for SINAMICS G120D Connecting cable PROFINET IE Connecting Cable M12-180/M12-180 for SINAMICS G120D Training case SINAMICS G120 Interactive Catalog CA 01 Chapter/Page 7/7

6/23

6XV1830-3D...

6/23

6/23

6ZB 6ZB4280-0C... E86060 E86060-D4001-A HTG HTG: 61 83 401 013. HTG: 61 88 201... ZKT ZKT: 10032... ZKT: 700...

8/4

6SL3262-1B 6SL3262-1F

4/111 4/111

7/3

6SL3263-1GA20-0GA0 6SL3264-1EA00-0EA0 6SL3264-1EA00-0FA0 6SL3298-0A 6SL3298-0B 6SL3298-0CA 6SL3300-1AE32-5AA0 6SL3362-0AG00-0AA1 6SL3500-0SF01-0AA0 6SL3500-0TF01-0AA0 6SL3500-0SK01-0AA0 6SL3500-0TK01-0AA0 6SL3501-0BE... 6SL3511-... 6SL3525-0PE 6SL3544-0FA2 6SL3555-0PA00-2AA0 6SL3555-0PL00-2AA0 6SL3555-0PM00-0AA0

5/17 4/112 4/112 8/5 8/5 3/9, 8/7 4/86 4/116 6/26 5/20 6/26 5/20 5/14 5/3 6/13 6/7 5/17, 6/22, 7/6 5/16 5/17

Connector set for motor 5/19, 6/24 cables Motor cables pre-fabricated 5/19, 6/24 at one end Connector set for motor 5/19, 6/24 cables Motor cables pre-fabricated 5/19, 6/24 at one end

9/16

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Conditions of sale and delivery

Terms and Conditions of Sale and Delivery


By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside of Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following terms apply exclusively for orders placed with Siemens AG. For customers with a seat or registered office in Germany The General Terms of Payment as well as the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry shall apply. For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office in Germany shall apply. For customers with a seat or registered office outside of Germany The General Terms of Payment as well as the General Conditions for Supplies of Siemens, Automation and Drives for Customers with a Seat or registered Office outside of Germany shall apply. For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a Seat or registered Office outside of Germany shall apply. General The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches only apply to devices for export. Illustrations are not binding. Insofar as there are no remarks on the corresponding pages, - especially with regard to data, dimensions and weights given these are subject to change without prior notice. The prices are in (Euro) ex works, exclusive packaging. The sales tax (value added tax) is not included in the prices. It shall be debited separately at the respective rate according to the applicable legal regulations. Prices are subject to change without prior notice. We will debit the prices valid at the time of delivery. Surcharges will be added to the prices of products that contain silver, copper, aluminum, lead and/or gold if the respective basic official prices for these metals are exceeded. These surcharges will be determined based on the official price and the metal factor of the respective product. The surcharge will be calculated on the basis of the official price on the day prior to receipt of the order or prior to the release order. The metal factor determines the official price as of which the metal surcharges are charged and the calculation method used. The metal factor, provided it is relevant, is included with the price information of the respective products. An exact explanation of the metal factor and the text of the Comprehensive Terms and Conditions of Sale and Delivery are available free of charge from your local Siemens business office under the following Order Nos.: 6ZB5310-0KR30-0BA1 (for customers based in Germany) 6ZB5310-0KS53-0BA1 (for customers based outside Germany) or download them from the Internet http://www.siemens.com/automation/mall (Germany: A&D Mall Online-Help System)

Siemens D 11.1 2009

9/17

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Export regulations

Export regulations
The products listed in this catalog / price list may be subject to European / German and/or US export regulations. Therefore, any export requiring a license is subject to approval by the competent authorities. According to current provisions, the following export regulations must be observed with respect to the products featured in this catalog / price list: AL Number of the German Export List Products marked other than N require an export license. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an AL not equal to N are subject to a European or German export authorization when being exported out of the EU. Export Control Classification Number Products marked other than N are subject to a reexport license to specific countries. In the case of software products, the export designations of the relevant data medium must also be generally adhered to. Goods labeled with an ECCN not equal to N are subject to a US re-export authorization. Even without a label or with an AL: N or ECCN: N, authorization may be required due to the final destination and purpose for which the goods are to be used. The deciding factors are the AL or ECCN export authorization indicated on order confirmations, delivery notes and invoices. Errors excepted and subject to change without prior notice.
I IA/VuL_ohne MZ/En 12.05.09

ECCN

9/18

Siemens D 11.1 2009

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Notes

Siemens D 11.1 2009

9/19

Siemens AG 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D


Appendix
Notes

9/20

Siemens D 11.1 2009

Siemens AG 2009

Catalogs
Industry Automation, Drive Technologies and Electrical Installation Technology
Further information can be obtained from our branch offices listed in the appendix or at www.siemens.com/automation/partner
Interactive catalog on DVD for Industry Automation, Drive Technologies and Electrical Installation Technology Catalog CA 01 Motion Control SINUMERIK & SIMODRIVE Automation Systems for Machine Tools SINUMERIK & SINAMICS Automation Systems for Machine Tools Drive Systems Variable-Speed Drives SINAMICS G110/SINAMICS G120 Inverter Chassis Units SINAMICS G120D Distributed Frequency Inverters SINAMICS G130 Drive Converter Chassis Units, SINAMICS G150 Drive Converter Cabinet Units SINAMICS GM150/SINAMICS SM150 Medium-Voltage Converters SINAMICS S150 Drive Converter Cabinet Units Asynchronous Motors Standardline Synchronous Motors with Permanent-Magnet Technology, HT-direct DC Motors SIMOREG DC MASTER 6RA70 Digital Chassis Converters SIMOREG K 6RA22 Analog Chassis Converters PDF: SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units SIMOVERT PM Modular Converter Systems SIEMOSYN Motors MICROMASTER 420/430/440 Inverters MICROMASTER 411/COMBIMASTER 411 SIMOVERT MASTERDRIVES Vector Control SIMOVERT MASTERDRIVES Motion Control Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES SIMODRIVE 611 universal and POSMO SIMOTION, SINAMICS S120 and Motors for Production Machines SINAMICS S110 The Basic Positioning Drive Low-Voltage Three-Phase-Motors IEC Squirrel-Cage Motors MOTOX Geared Motors Automation Systems for Machine Tools SIMODRIVE Motors Converter Systems SIMODRIVE 611/POSMO Automation Systems for Machine Tools SINAMICS Motors Drive System SINAMICS S120 Drive and Control Components for Hoisting Equipment Mechanical Driving Machines Flender Standard Couplings MD 10.1 HE 1 Systems Engineering Power supplies SITOP power and LOGO! Power System cabling SIMATIC TOP connect Electrical Installation Technology PDF: ALPHA Distribution Boards and Terminal Blocks PDF: ALPHA 8HP Molded-Plastic Distribution System PDF: BETA Low-Voltage Circuit Protection PDF: DELTA Switches and Socket Outlets PDF: GAMMA Building Management Systems ET A1 ET A3 ET B1 ET D1 ET G1 TELEPERM M Process Control System PDF: AS 488/TM automation systems PLT 112 System Solutions Applications and Products for Industry are part of the interactive catalog CA 01 KT 10.1 KT 10.2 SIMATIC Sensors Sensors for Factory Automation FS 10 NC 61 SIMATIC NET Industrial Communication IK PI D 81.1 D 87.1 NC 60 D 11.1 SIMOTION, SINAMICS S120 and Motors for Production Machines SINAMICS S110 The Basic Positioning Drive Low-Voltage Controls and Distribution SIRIUS, SENTRON, SIVACON Controls and Distribution Technical Information SIRIUS, SENTRON, SIVACON SIDAC Reactors and Filters SIVENT Fans SIVACON 8PS Busbar Trunking Systems DA 12 DA 21.1 DA 21.2 DA 22 DA 45 DA 48 DA 51.2 DA 51.3 DA 65.10 DA 65.11 DA 65.3 DA 65.4 PM 21 PM 22 SIMATIC HMI Human Machine Interface Systems SIMATIC Industrial Automation Systems Products for Totally Integrated Automation and Micro Automation SIMATIC PCS 7 Process Control System Add-ons for the SIMATIC PCS 7 Process Control System Migration solutions with the SIMATIC PCS 7 Process Control System pc-based Automation SIMATIC Control Systems ST 80 Process Instrumentation and Analytics Field Instruments for Process Automation PDF: Indicators for panel mounting SIREC Recorders and Accessories SIPART, Controllers and Software PDF: Products for Weighing Technology Process Analytical Instruments PDF: Process Analytics, Components for the System Integration FI 01 MP 12 MP 20 MP 31 WT 10 PA 01 PA 11 Catalog NC 60 NC 61 PM 21 PM 22

D 11 D 12 D 21.3 D 86.1 D 86.2

LV 1 LV 1 T

LV 60 LV 65 LV 70

ST 70 ST PCS 7 ST PCS 7.1 ST PCS 7.2 ST PC ST DA

PDF: These catalogs are only available as pdf files.

IA DT ET/3U/En 08.04.09

Siemens AG 2009

Siemens AG Industry Sector Drive Technologies Division Standard Drives Postfach 3180 91050 ERLANGEN GERMANY www.siemens.com/sinamics

Subject to change without prior notice Order No.: E86060-K5511-A111-A6 -7600 3P.8122.69.02 / Dispo 18404 KG 0709 10 E 240 En Printed in Germany Siemens AG 2009

The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.

iemens AG 2

Catalog D 11.1 2009

SINAMICS G110, SINAMICS G120, SINAMICS G110D, SINAMICS G120D