Triple-Band Panel Dual Polarization Half-Power Beam Width Adjust. Electr. Downtilt
Triple-Band Panel Dual Polarization Half-Power Beam Width Adjust. Electr. Downtilt
Triple-Band Panel Dual Polarization Half-Power Beam Width Adjust. Electr. Downtilt
Dual Polarization X X X
Half-power Beam Width 67° 65° 65°
Adjust. Electr. Downtilt 0°– 10° 0°– 6° 0°– 6°
set by hand or by optional RCU (Remote Control Unit)
XXXPol Panel 806–960/1710–1880/1920–2170 67°/ 65°/65° 16.5/17.5/18dBi 0°–10°/0°–6°/0°–6°T
Type No. 742 271
Frequency range 806–960 1710–1880 1920–2170
806– 866 MHz 824– 894 MHz 880– 960 MHz 1710 – 1880 MHz 1920 – 2170 MHz
Polarization +45°, –45° +45°, –45° +45°, –45° +45°, –45° +45°, –45°
Gain 2 x 16 dBi 2 x 16.1 dBi 2 x 16.3 dB 2 x 17.5 dBi 2 x 18 dBi
Horizontal Pattern:
Half-power beam width 69° 68° 67° 65° 65°
Front-to-back ratio, copolar > 25 dB > 25 dB > 25 dB > 24 dB > 25 dB
Cross polar ratio Typically: Typically: Typically: Typically: Typically:
Maindirection 25 dB 25 dB 25 dB 18 dB 20 dB
Sector > 10 dB > 10 dB > 10 dB > 10 dB > 10 dB
Vertical Patern:
Half-power beam width 9.5° 9.3° 9.0° 4.7° 4.3°
Electrical tilt 0°– 10° 0°– 6 0°– 6
continuously adjustable
Sidelobe suppression for first 0° ... 5° ... 10° T 0° ... 5° ... 10° T 0° ... 5° ... 10° T 0° ... 3° ... 6° T 0° ... 3° ... 6° T
sidelobe above main beam 15 ... 15 ... 13 dB 15 ... 15 ... 13 dB 15 ... 15 ... 13 dB 18 ... 17 ... 16 dB 18 ... 16 ... 15 dB
Impedance 50 Ω
VSWR < 1.5
Isolation: Intrasystem > 30 dB
Isolation: Intersystem Typically: > 50 dB (806– 960 // 1710 – 1880 MHz)11
Typically: > 50 dB (806– 960 // 1920 – 2170 MHz)11
> 30 dB (1710 – 1880 // 1920 – 2170 MHz)
Intermodulation IM3 < –150 dBc (2 x 43 dBm carrier)
Max. power per input 300 W 200 W 200 W
(at 50 °C ambient temperature)
806– 960 +45°/ –45° Polarization
67°
130°
10°
10 10
3
dB
dB
0
806– 960 806–960
0 –45° +45°
Horizontal Pattern Vertical Pattern
0°– 10° electrical downtilt 1920 –2170 1920 –2170 1710 –1880 1710–1880
–45° +45° –45° +45°
1710 –1880 +45°/ –45° Polarization
125°
65° 7-16 7-16 7-16 7-16 7-16 7-16
5.1°
Mechanical specifications
Subject to alteration.
10 10
dB
dB
3 3
0 0
9
Weight Units per
Type No. Description Remarks
approx. antenna
2058
2101
2141
733 680 1 clamp Mast: 380 – 521 mm diameter 5.3 kg 2
850 10007 1 downtilt kit Downtilt angle: 0° – 11° 5.9 kg 1
The downtilt kit can only be used in combination with the clamps
type nos. 738 546, 850 10002, 850 10003.
Wall mounting: No additional mounting kit is needed.
35–42
Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded. Adjustment mechanism
with integrated scale
Environmental conditions: Kathrein cellular antennas are designed to operate under the environ-
mental conditions as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
149
167
– Low temperature: –55 °C
134
106
88
– High temperature (dry): +60 °C
45
Ice protection: Due to the very sturdy antenna construction and the 50
103
protection of the radiating system by the radome, the antenna remains 180
operational even under icy conditions. 203
262
Environmental tests: Kathrein antennas have passed environmental tests as recommended Bottom view
in ETS 300 019-2-4. The homogenous design of Kathrein’s antenna (Dimensions refer to radome)
families use identical modules and materials. Extensive tests have been
performed on typical samples and modules. RCU
RCU RCU
–45° +45°
–45° +45° 806–960 –45° +45°
1920–2170 1710–1880
Layout of interface
Please note: As a result of more stringent legal regulations and judgements regarding product liability, we are
obliged to point out certain risks that may arise when products are used under extraordinary operating
conditions.
Subject to alteration.
The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby
respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are
calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional
dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna
or even cause it to fall to the ground. These facts must be considered during the site planning process.
The installation team must be properly qualified and also be familiar with the relevant national safety
936.3227/b
regulations.
The details given in our data sheets have to be followed carefully when installing the antennas and
accessories.
The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers
must be obeyed.
1
2
2
➀ Adjustment wheel with twist-lock ➀ Thread for fixing the protective To set the downtilt angle exactly,
function. cap or the RCU (Remote Control you must look horizontally at the
➁ Downtilt spindle with integrated Unit). scale. The lower edge of the gear-
scale. ➁ Gearwheel for RCU power drive. wheel must be used for alignment.
0° – max.°
max.° – 0°
Remove the protective cap. Set downtilt angle by rotating the Screw on the protective cap again.
adjustment wheel.
For a description of RCU installation please refer to the respective data sheet.
Internet: www.kathrein.de 742 271 Page 3 of 4
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973
General Instructions for Feederline Installation
for Triple-band Antennas
with Kathrein Installation Set, Type No. 850 10005
Please note: To avoid any damage to the interfaces, please ensure that only suitable tools are used. To
tighten the feederline connector interfaces, we strongly recommend using a special Kathrein installation tool
(as shown below) in combination with a standard torque-wrench.
2
Adjustment mechanisms (1 – 3)
1 3
8 6 4 5 7 9 Feederline connectors (4 – 9)
There are six feederline connectors and three adjustment mechanisms located at the bottom
of the antenna.
Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required,
nor is it recommended by the connector manufacturers.
Page 4 of 4 742 271 Internet: www.kathrein.de
KATHREIN-Werke KG . Anton-Kathrein-Straße 1 – 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973