Activity 1.3.

1 Solar Hydrogen System VEX


This activity was written to be used with the Heliocentris
fuel cell. If you are using the fuel cells from a different
manufacturer, refer to that manufacturers instructions to
be sure that the equipment is used as designed.

1. Read the Fuel Cell User Guide.


2. Follow the directions in the Fuel Cell User Guide
under the section Preparing the Fuel Cell for Use.

Circuit Schematics

3. Shine a bright light source on the solar panel, always


keeping at least 8 inches of separation between the
two to avoid melting the solar module plastic.
Set your multimeter to measure voltage and connect
the multimeter test leads to the solar panel
terminals. Move the solar panel or light source to
determine the location that produces the highest
voltage value. You may want to mark the positions
with some tape. Record the open-circuit voltage.
Note the current is zero, since a voltmeter has nearly
infinite resistance.
VOC = Open-Circuit Voltage __1.49________
Power = VOC x 0 A = 0 W

2012 Project Lead The Way, Inc.


POE Activity 1.3.1 Solar Hydrogen System VEX Page 1

4. With the test leads disconnected, set your


multimeter to measure current. Return the solar
module to the same exact position that produced the
highest voltage value and measure the current.
Record this short-circuit current. Note that the
voltage is zero, since an ammeter has nearly zero
resistance.
ISC = Short-Circuit Current ___98_MA______
Power = 0 V x ISC = 0 W
5. Calculate the amount of power that would be produced by the solar module if it could simultaneously produce the voltage and
current you measured in the previous two steps.
For this illumination level, the solar module will deliver, at most, about 70% of this theoretical maximum, and will do so at a
resistance between zero and infinite resistance.
Maximum Theoretical Power = VOC x ISC = __.19 WATTS_____
6. Attach the solar panel to the solar hydrogen
automobile. Using a standoff or another suitable
method, prop up one end of the chassis so that the
motor-driven wheel is not in contact with the ground.
Connect the motor leads to the solar module using
the breadboard to make the connections. Position
the light source to produce maximum voltage leaving
a minimum distance of 8 inches between solar
module and the lamp. Is there enough power to turn
the motor? If so, is there enough power to turn the
motor with the wheels on the ground?
__YES
AND YES THERE IS ENOUGH W WHEELS ON
GROUND._______
7. Set your multimeter to measure voltage. Connect the
multimeter test leads to the solar module terminals.
2012 Project Lead The Way, Inc.
POE Activity 1.3.1 Solar Hydrogen System VEX Page 2

Record the load voltage value.(Drive gear should be


engaged)
V = Load Voltage _N/A_________
8. Disconnect the test leads and set your multimeter to
measure current. Connect the multimeter in series
with the solar module. Record the load current.
I = Load Current = ____N/A______
9. Calculate the power delivered by the solar module when it is loaded by the motor with the wheels off the ground.
P = Load Power = I V = __.0065________ for solar module.
10. Energize the fuel cell by using one of the power sources according to the directions in the Fuel Cell User Guide under the
section Powering the Fuel Cell (Electrolysis).

Fuel cells can be damaged by high current. If using a DC power supply with the Heliocentris fuel cell, do not use more than 500 mA.
Do not use a battery to energize the fuel cell.
11. After the fuel cell is energized, attach the fuel cell to the motor using the breadboard to make the connections. Is there enough
power to turn the motor? If so, is there enough power to turn the motor with the wheels on the ground? _YES_____
12. With the test leads disconnected, set the multimeter
to measure voltage. Connect the multimeter test
leads to the fuel cell terminals. Record the voltage
value.
V = Load Voltage __1.47 V________
13. With the test leads disconnected, set the multimeter
to measure 10 A current, using the 10 A meter
receptacle. Connect the test leads in series with the
fuel cell.
Caution! Never measure current from the fuel cell
2012 Project Lead The Way, Inc.
POE Activity 1.3.1 Solar Hydrogen System VEX Page 3

without a resistor, motor, or other load in series with


the ammeter. Doing so can permanently damage
the fuel cell.
Record the current value.
Load Current = __N/A________
14. Calculate the power delivered by the fuel cell.
P = Load Power = I V = _______N/A___ for fuel cell.
15. Remove the fuel cell and solar module and attach the two AAA battery holders to your vehicle using zip ties. Using the
breadboard, connect the batteries in series with each other and with the motor. (See next step for wiring hints.) Is there enough
power to turn the motor? If so, is there enough power to turn the motor with the wheels on the ground? __N/A____

16. With the test leads disconnected, set the multimeter


to measure voltage. Connect the multimeter test
leads to the motor terminals. Record the voltage
value.
V = Load Voltage ___N/A_______
17. With the test leads disconnected, set the multimeter
to measure 10 A current, using the 10 A meter
receptacle. Connect the test leads in series with the
motor terminals. Record the current value.
Load Current = ____N/A______

18. Calculate the power delivered by the batteries in


series.
2012 Project Lead The Way, Inc.
POE Activity 1.3.1 Solar Hydrogen System VEX Page 4

P = Load Power = I V = ___N/A_______ for batteries


in series

19. Using the breadboard, connect the batteries in parallel with each other and with the motor. Is there enough power to turn the
motor? If so, is there enough power to turn the motor with the wheels on the ground? __N/A____
20. With the test leads disconnected, set the multimeter
to measure voltage. Connect the multimeter test
leads to the motor terminals. Record the voltage
value.
V = Load Voltage ______N/A____
21. With the test leads disconnected, set the multimeter
to measure 10 A current, using the 10 A meter
receptacle. Connect the test leads in series with the
motor terminals. Record the current value.
Load Current = ____N/A______

22. Calculate the power delivered by the batteries in


parallel.
P = Load Power = I V = _______N/A___ for batteries in
parallel

2012 Project Lead The Way, Inc.