Elo Touch Solutions - E281-2310 IntelliTouch SmartSet Serial Controller SEGA2 Y SIGMA PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Elo Touch Solutions E281-2310 IntelliTouch SmartSet Serial Controller

1 de 2

http://www.elotouch.com/Support/TechnicalSupport/Controllers/2310.asp

Worldwide

E281-2310 IntelliTouch SmartSet Serial Controller

Jumper J2: Installed = E281-4002 controller emulation


Diagnostic LED: Green
Normal, without touch: Should blink at 1 Hz.
(on solid indicates Power-on Self Test failure)
Normal, with touch: On solid while touched
(on after release: host failed to remove the data)
Fast blink (2 or 3/sec):
Communications error

Factory Jumper Settings


J0 Out Reserved
J1 Out Reserved
J2 Out No Emulation Mode
J3 Out Reserved

Power Requirements
5 Vdc, nominal (5%)
140 mA, typical at = 5 Vdc

P2 Connections
Serial Communication Connections
Pin

DB9

DB 25

Data Carrier Detect (DCD)

Data Set Ready (DSR)

Receive Data (RxD)

Ready To Send (RTS)

Transmit Data (TxD)

Clear To Send (CTS)

Data Terminal Ready (DTR) 4

20

N/C

22

Ground (GND)

N/A

N/A

10 Key

P4 Connections

06/05/2015 02:14 p.m.

Elo Touch Solutions E281-2310 IntelliTouch SmartSet Serial Controller

2 de 2

http://www.elotouch.com/Support/TechnicalSupport/Controllers/2310.asp

Pin Signal
1

DC+

DC- (tied to pin 4)

N/C

DC- (tied to pin 2)

LED Remote

Key

N/C

Chassis Ground

- Reset

10 N/C

Elo Touch Solutions


Quick Links

Resources Quick Links

Legal

Warranty Policies

Terms of Sale

Contact Us

Locate a Reseller

Careers at Elo

Find Documents & Drawings

Languages
Site Map
Newsletter
Copyright 2014 Elo Touch Solutions, Inc. All rights reserved.

Privacy Policy

06/05/2015 02:14 p.m.

You might also like