RM4UA31F: Product Data Sheet
RM4UA31F: Product Data Sheet
RM4UA31F: Product Data Sheet
Characteristics
RM4UA31F
Range of product
Zelio Control
Product or component
type
Relay type
Relay name
RM4U
Time delay
Adjustable 0.05...30 s
Power consumption in
VA
1.9...3.3 VA AC
Measurement range
Electrical connection
2 C/O
Complementary
[Us] rated supply voltage
110...130 V AC 50/60 Hz
Output contacts
2 C/O
43000 Ohm
6600 Ohm
71000 Ohm
20 V
60 V
80 V
+/-5 %
<= 0.06 % per degree centigrade depending permissible ambient air temperature
<= 0.5 % within the supply voltage range (0.85...1.1 Un)
10 P
<= 0.07 % per degree centigrade depending on the rated operational temperature
<= 0.5 % within the supply voltage range (0.85...1.1 Un)
Hysteresis
Marking
CE : EMC 89/336/EEC
CE : LVD 73/23/EEC
Overvoltage category
0.85...1.1 Uc
Supply frequency
50/60 Hz +/- 5 %
> 0.1 Uc
Operating position
Tightening torque
0.6...1.1 N.m
Mechanical durability
30000000 cycles
8A
Apr 1, 2012
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Switching capacity in mA
10 mA at 12 V
Switching voltage
<= 440 V AC
250 V AC
Contacts material
Number of cables
Height
78 mm
Width
22.5 mm
Depth
80 mm
(15-16-18)OC
(25-26-28)OC
(A1-A2)CO
(C-B1-B2-B3)CO
9 mm pitches
2.5
Product weight
0.168 kg
Environment
Standards
EN/IEC 60255-6
Product certifications
CSA
GL
UL
-40...85 C
-20...65 C
Relative humidity
Vibration resistance
Shock resistance
IP degree of protection
Pollution degree
2.5 kV
4.8 kV
Disturbance radiated/conducted
Compliant
0627
2
Downloaded from Elcodis.com
electronic components distributor
RM4UA31F
Screw fixing
4
Downloaded from Elcodis.com
electronic components distributor
RM4UA31F
RM4UA31F
B1-C
0.050.5V
B2-C
0.33V
B3-C
0.55V
RM4UA2
B1-C
B2-C
550V
B3-C
10100V
110V
30300V
B3-C
50500V
B1-C
0.050.5V
B2-C
0.33V
B3-C
0.55V
RM4UA2
B1-C
B2-C
550V
B3-C
10100V
110V
30300V
B3-C
50500V
(1)
(2)
Tachogenerator
Overspeed
6
Downloaded from Elcodis.com
electronic components distributor
RM4UA31F
X
Y
Current broken in A
Millions of operating cycles
Curve 2: Reduction factor k for inductive loads (applies to values taken from durability Curve 1)
X
Y
Example: An LC1-F185 contactor supplied with 115V/50Hz for a consumption of 55VA or a current consumption equal to 0.5A and cos =
0.3.
For 0.5A, curve 1 indicates a durability of approximately 1.5 million operating cycles.
As the load is inductive, it is necessary to apply a reduction coefficient k to this number of cycles as indicated by curve 2.
For cos = 0.3: k = 0.6
The electrical durability therefore becomes:
6
DC Load
Load limit curve
X
Y
1
2
3
Current in A
Voltage in V
L/R = 20 ms
L/R with load protection diode
Resistive load
RM4UA31F
Function Diagram
Overvoltage Control
Function >
t
Time delay
U
Supply voltage
A1A2
US1 Setting voltage threshold
US2 Voltage measured
15-18,Output relays connections (refer to Connections and Schema)
15-16;
25-28,
25-26
Relay status: black color = energized.
NOTE: Hysteresis is adjustable between 5 and 30%: for overvoltage h=(US1-US2)/US1. A measuring cycle lasts only 80ms, which
allows rapid detection of changes in current.
NOTE: The measurement ranges can be extended above 500V by adding a resistor. The measurement range on AC supply can be
extended by means of a voltage transformer, the secondary of which is connected to the measuring terminals of the corresponding RM4.
Function Diagram
Undervoltage Control
Function <
t
Time delay
U
Supply voltage
A1A2
US1 Setting voltage threshold
US2 Voltage measured
15-18,Output relays connections (refer to Connections and Schema)
15-16;
25-28,
25-26
Relay status: black color = energized.
NOTE: Hysteresis is adjustable between 5 and 30%: for undervoltage h=(US2-US1)/US1. A measuring cycle lasts only 80ms, which
allows rapid detection of changes in current.
NOTE: The measurement ranges can be extended above 500V by adding a resistor. The measurement range on AC supply can be
extended by means of a voltage transformer, the secondary of which is connected to the measuring terminals of the corresponding RM4.
8