Presentation Contents
Applications
Eatons Core Technologies
Power Xpert UX
Safe, Reliable and Efficient Switchgear for
all Indoor Medium Voltage Applications
Applications
Medium Voltage Switchgear
and Controlgear
Primary/Secondary Switchgear
& Motor Control
In
Mining
Utility Networks
Marine Systems
Process Industries
Commercial Construction
Pharmaceutical Industries
Water & Waste Water Treatment
Infrastructure Construction Projects
2009 Eaton Corporation. All rights reserved.
IEC Standards
Power Xpert UX and W-VACi comply with all
relevant IEC standards and are third party
tested and certified
IEC 62271-1
IEC 62271-200
IEC 62271-100
IEC 62271-102
IEC 60265-1
IEC 60470
Common specifications
Metal-enclosed switchgear
Circuit-breakers
Earth switch
Switch disconnectors
Contactors
CESI
Reliable
Compact Design
Maintenance Free
Power Xpert UX
A global design for IEC MV
withdrawable switchgear
Power Xpert UX12 12kV rated
Power Xpert UX17 17.5kV rated
Basic Design
Loss of Service Continuity
LSC2B
Partition Class
PM
11
11
Basic Design
Accessibility of Compartments
Cable:
Interlocked Controlled / Procedure
Circuit Breaker:
Interlocked Controlled
Busbars:
Non-Accessible / Tool Based
Ingress Protection
External IP4X (IP41 option)
Internal IP2X (IP3X option)
2009 Eaton Corporation. All rights reserved.
12
12
Detailed Design
1 Arc Chamber
2 Low-voltage Wire-way
3 Low-voltage Compartment
4 Busbar Compartment
8 Current Transformers
9 Voltage Transformers
10 Cable Terminations
11 Earth Bar
2009 Eaton Corporation. All rights reserved.
13
13
1 Arc Chamber
Internal Arc Classification AFLR
Power Xpert UX has IAC ratings of
12kV & 17.5kV ratings:
25kA-1s; 31.5kA-1s; 40kA-1s & 50kA-0.5s
24kV ratings:
25kA-1s
14
14
3 Basic Design
Low-Voltage Compartment
2 Low-voltage
wire-way
Low-voltage
Compartment 1
Protection Relay 2
Indicators
Mimic Diagram 3
Breaker Position
Instruments 4
Breaker Status
Voltage Detection 5
System (VDS)
Earth Switch
15
15
3 Low-Voltage Compartment
2
16
16
3 Low-Voltage Compartment
3 Clear to understand silk screen mimic
diagram of each circuit
4 Ammeter and Voltmeter with or without phase
selector switches are possible
5 Voltage Detection System (VDS) is driven
from capacitor dividers mounted in bushings
attached to the cable
17
17
3 Low-Voltage Compartment
2
Low-voltage
position 4indicator
Instruments
7
8
6 Breaker Position
Disconnected
7
Breaker Status
Earth Switch
18
18
4 Busbar Compartment
Totally enclosed in earthed
metal compartment which
vents directly into the
integral arc chamber.
Fully insulated over entire
length
19
19
4 Busbar Compartment
12kV and 17.5kV
Up to 4000A fan cooled,
3150A natural cooing.
3 second Short Circuit ratings
of: 25kA, 26.3kA, 31.5kA,
40kA & 50kA
24kV
Up to 2500A
20
20
2. Eatons range of
Vacuum Contactors.
The SL
2009 Eaton Corporation. All rights reserved.
21
21
9 Viewing Window
22
22
10
11
23
23
24
24
25
25
+
World Leading
Vacuum Interrupters
Epoxy Encapsulation
Technology
Universal Mechanism
Assembly
W-VACi Vacuum
Circuit Breaker
26
26
Frame 1
Frame 2
Frame 3
12kV 1250A
12kV 2000A
12kV 4000A
17.5kV 1250A
17.5kV 2000A
17.5kV 4000A
24kV 1250A
24kV 2500A
27
27
205MM
Frame 1
205 mm height
Frame 1
275 mm height
between line and load
12kV = 630A
12kV = 1250A
17.5kV = 630A
17.5kV = 1250A
2009 Eaton Corporation. All rights reserved.
28
28
310MM
275MM
Frame 2
Frame 3
275 mm height
between line and load
310 mm height
12kV 2000A
12kV 4000A
17.5kV 2000A
17.5kV 4000A
24kV 1250A
24kV 2500A
29
29
W-VACi Ratings
Refer to Product Guide for full information
W-VACi Vacuum Circuit Breaker Ratings
Description IEC 62 271-100
Product Designation
Rated Voltage
Rated Frequency
Rated
Insulation
Level
kV
Rating
120W-VACi
12
175W-VACi
17.5
240W-VACi
24
Unit
Hz
50/60
50/60
50/60
kV
28
38
50
kV
75
95
125
kA/50Hz
66/80/100/125
66/80/100/125
50/63
kA/60Hz
65/82/104/130
65/82/104/130
52/65/82
25/26.3/31.5/40/ 50
25/31.5/40/50
20/25/31.5
kA
kA
25/26.3/31.5/40/50
25/31.5/40/50
20/25/31.5
kA
65/66/82/104/130
65/82/104/130
52/65/82
Electrical Endurance
Mechanical Endurance
Operations M2 (20,000)
M2 (20,000)
M2 (20,000)
O-0.3s-CO-15s-CO
110/120/127VAC 50/60HZ,
208/220/240VAC 50/60HZ,
24/48/60VDC, 110/125VDC,
220/250VDC
C2 (400A rating only) [1]
O-0.3s-CO-15s-CO
110/120/127VAC 50/60HZ,
208/220/240VAC 50/60HZ,
24/48/60VDC, 110/125VDC,
220/250VDC
O-0.3s-CO-15s-CO
110/120/127VAC 50/60HZ,
208/220/240VAC 50/60HZ,
24/48/60VDC, 110/125VDC,
220/250VDC
C2 (400A rating only) [1]
Cable Charging
C2 (25A)
C2 (31.5A)
C2 (31.5A)
Auxiliary Contacts
10 AC / 2 DC
10 AC / 2 DC
10 AC / 2 DC
Operating Sequence
Auxiliary Control Voltage
[1] = 630 A breaker only. No Back to Back Capacitor Switching for other ratings.
30
30
Withdrawable carriage
consistent with W-VACi
Same interlocks
Same position indicators
Same racking mechanism
2009 Eaton Corporation. All rights reserved.
31
31
6 Automatic Shutters
Individually operated
Earthed Metal
Can be padlocked in closed
position
32
32
33
33
34
34
8 Current Transformers
Cast-resin, block-type CTs
are offered as standard
Up to 4 CTs per phase may
be possible depending on
rating
Option for wire-wound CTs
is available
35
35
9 Voltage Transformers
Fixed (demountable) circuit
voltage transformers.
Withdrawable primary fuses
provide isolation
Option for withdrawable
truck mounted busbar
voltage transformers
mounted in separate panel.
36
36
10 Cable Terminations
Bottom cable entry is
standard, option for Top
cable entry possible
Front and/or Rear cable
access
Depending on rating and
cable size up to 9 single
core cables per phase
possible
2009 Eaton Corporation. All rights reserved.
37
37
10 Cable Terminations
Easy Front cabling access:
1. Remove breaker/contactor
2. Remove mid-pan
3. Remove voltage transformers
4. Full access now available
38
38
11 Earth Bar
Fault tested earth bar
system
Effective and easy
connection to the station
earth
New image
39
39
Panel Configurations
Truck Configurations
Panel Configurations
41
41
Truck Configurations
42
42
Electrical Ratings
& Dimensions
kV
A
kA-3s
kA-s
Circuit-Breakers:
Rated current max
Short time current
A
kA-3s
Panel width
Panel height
mm
mm
12 & 17.5
1250, 2000, 3150/(4000FC)
25, 26.3, 31.5, 40, 50
25-1, 31.5kA-1, 40-1, 50-0.5
44
44
kV
A
24
1250, 2500
kA-3s
kA-1s
20, 25
25
Circuit-Breakers,
Rated current max
Short time current
A
kA-3s
Panel width
Panel height
mm
mm
800,1000
2200 / 2760
* Height over the arc chamber
45
45
Panel width
600 mm
800mm
1000mm
630 A / 1250 A
2000A
12 kV and 17.5 kV
Max. rating
Depth
1310
1310 / 1490*
1490
Height (A)
2200
2200
2200
2760
2760
2760
860 / 880
1230
1670
800 A / 1250 A
2000 A / 2500 A
Depth
1570
1570
Height (A)
2320
2320
2870
2870
1460 / 1480
1820
46
46
47
47