www.siemens.com/ultrasound
Table of Contents
INTRODUCTION................................................................1 Complete patient care solution.......................................1 Portability with ease. .....................................................1 Support you can count on..............................................1 EXTENDING TECHNOLOGIES. ............................................1 High frequency imaging.................................................1 TEI. ...............................................................................1 XView. ..........................................................................1 MView...........................................................................2 TPView..........................................................................2 VPan. ............................................................................2 APPLICATION USAGE........................................................2 SYSTEM OVERVIEW..........................................................2 Control Panel.................................................................2 Cart Design....................................................................2 Monitor.........................................................................2 Operating Modes...........................................................3 Image Display Modes.....................................................3 Image Formats...............................................................3 Modularity.....................................................................3 Transducer Formats. ......................................................3 Operating Console.........................................................4 Transmit........................................................................4 Receive..........................................................................4 RF Signal processing. .....................................................4 2D.................................................................................4 M-mode. .......................................................................4 Color.............................................................................4 Doppler PW. ..................................................................4 Doppler CW...................................................................5 Echo Process Controls. ...................................................5 ECG...............................................................................5 TRANSDUCERS. ...............................................................11 Convex Array Probes . ..................................................12 Linear Array Probes .....................................................12 Phased Array Probes ....................................................13 Specialty Probes ..........................................................13 Non Imaging Pencil probe .........................................14 Disposable Needle Guides by Protek1 ............................14 Disposable Needle Guides by CIVCO2 ............................14 MEASUREMENTS AND REPORTING...................................7 Standard System Packages. ............................................7 Advanced Optional Packages..........................................7 General Imaging ...........................................................8 Vascular. .......................................................................9 Cardiology.....................................................................9 OB-Fetal......................................................................10 Archiving Capabilities.....................................................5 Connectivity..................................................................5 Image File Formats. .......................................................5 Video I/O.......................................................................6 Printing.........................................................................6 Video Requirements.......................................................6 Video Tape Recorder. .....................................................6 DICOM Classes...............................................................6 Software. ......................................................................6 Safety Requirements . ....................................................6 System .........................................................................6 Cart...............................................................................7 Power Supply (mains). ...................................................7 Battery .........................................................................7 Power Cables.................................................................7 Operating Requirements. ...............................................7 Storage Requirements....................................................7
1 2
www.protekmedical.com www.civcomedical.com
ii i
EXTENDING TECHNOLOGIES
High frequency imaging Up to 18.0 MHz bandwidth on linear transducers to provide detailed and precise imaging, especially in superficial investigations such as MSK application Multiple transmission frequency to scan deeper structures without changing probes TEI Harmonic imaging: dedicated hardware and software processing the second harmonic frequencies improving B-mode image quality, and diagnostic confidence in technically difficult patients Available on all imaging transducers Three selectable frequencies; General, Resolution, Penetration Available in combination with Color Doppler (C), M-mode, Power Doppler XView Speckle reduction: elaborates pattern of single frame at the pixel level, eliminating speckle and noise artifacts, dynamically enhancing tissue margins, improving tissue conspicuity Customizable presets (X Smooth, X Detail, X Enhancement) enable real-time optimization of the image process algorithm
* Including system parts and system specific transducers, excluding specialty transducers and accessories.
MView Spatial compounding: combined contributions of standard and steered ultrasound beams to optimize image quality and improve detection of anatomical structures Up to 15 angles of view within the same image TPView Trapezoid imaging: enlarged field of view on all linear probes, allowing scanning of extended structures without losing resolution Specially suited for breast, vascular, musculoskeletal, and thyroid applications VPan Panoramic view: dedicated software merging multiple B-mode images into one panned image displayed on the screen in real-time; auto fit of composite, image zoom, merging level, frame marker, colorize, and distance measurement Extended field of view supports visualization of the entire organ. Areas of interest such as musculoskeletal and lesions associated with abdominal, breast and small parts can be more easily studied
SYSTEM OVERVIEW
Control Panel Ergonomically designed and illuminated for ease of use Full alphanumeric QWERTY keyboard Logical grouped controls Customizable keys Dedicated technology buttons; 2D, M-mode, C, PW, CW Dedicated function keys; Start/End exam, Menu, Probe/User preset selection, Archive review, Exam review, Mark, Report, Measurement, Line/Update (split modes), Dual imaging, Image store, Clip store, Options key (Annotations, ECG, VTR, Power and Edit ID), Auto/Gain, Action, Rec/Print, Depth/Zoom, 8 TGC Siemens Select key (S) managing operationdependent software keys and special functions on screen Integrated speakers Dedicated footswitch connector Cart Design Ergonomic and compact for easy maneuverability Four probe holders plus one Pencil probe holder One gel holder ECG cable holders Probe and ECG cable management system Multi-directional wheels with breaking mechanism and locking levers Height adjustable for maximum ergonomics On-board peripheral storage Foot rest for added comfort Rubber bumpers to prevent wall contact Monitor 15 XVGA LCD monitor (1024x768 aspect ratio) Contrast digital adjustment
APPLICATION USAGE
The ACUSON P300 ultrasound system is specifically designed for the following applications: Abdominal (Adult, Pediatric, Neonatal) Adult Transcranial Breast Cardiac (Adult, Pediatric, Neonatal) Emergency General Imaging Gynecology Intraoperative/Interventional Musculoskeletal OB/GYN Small Parts Vascular
Information displayed on monitor: Application Selected preset On-line help for measurements Date & hour Type of probe Probe orientation Operating frequency range Acoustic power output Gray map Dynamic range Compression Persistence Enhancement XView MView Depth Focus Doppler angle Color & Spectral Doppler filter Sample volume size PRF Gain 2d C PW/CW frame rate Biopsy line Patient data Hospital data and annotations Body markers Remote digital printing and storage status Remote DICOM printing and storage status Heartbeat Timer Sweep time indication on trace Icons on top right for XView AutoAdjust MView
Operating Modes 2D (B-mode) B-mode steering B-mode AutoAdjust Colorize 2D, M-mode and PW/CW PW/CW Doppler Non-imaging CW PW/CW Doppler AutoAdjust C (Color Doppler) TEI (Harmonic Imaging) TPView (Trapezoid Imaging) VPan (Panoramic Imaging) Bidirectional Power Doppler Image Display Modes 256 gray levels or B-color levels 32 bits Color levels Orientation: Left/Right, Up/Down Real-time Triplex mode 2D+2D (with or without C or PWR D) 2D+M-mode (update or Real-time Duplex) 2D+C+M-mode (update) 2D+Doppler (update or Real-time Triplex) 2D+PWR D 2D+PWR D+Doppler (update or Real-time Triplex) Colorize on all combinations Image Formats Imaging: Full, Split, Multiple, Left/Right, Up/Down Tracing: Split, Dual (scroll by line) Modularity Software options Application license Transducer Formats Multi-frequency electronic: Convex array, Phased array, Linear array, and Pencil CW
Operating Console Digital modular platform Dynamic range up to 210 dB User presets (unlimited customizable) for every probe and application
Maps: up to 5 post processing gray maps, up to 7 color tint scales Zoom: variable magnification up to 4x (Real-time) and up to 32x (Frozen) XView processing (Speckle Reduction Algorithm) PRF: up to 11 KHz Biopsy kits and display lines Gain and TGC auto-adjustment M-mode Sweep time: 2 16 sec (step 1s) PRF: 1 KHz Color Frequencies: 2.0 8.0 MHz (2.0, 2.5, 2.9, 3.3, 5.0, 6.6, 8.0 MHz) Sampling PRF: 350 Hz 11 KHz Wall filters: 4 levels, depending on PRF Data dynamic: 10 bit (+5 for intensity) Maps: up to 16 Frame rate: up to 40 Hz Frame interpolation Interleave: up to 16 lines Samples: up to 512/line Packet size: 4 28 Format: ROI with/without wider b/w Size: 15-85 % of max b/w size Steering (linear probes): 3 steps (6/12/18) Doppler PW Frequencies: 2.0 8.0 MHz (2.0, 2.5, 2.9, 3.3, 5.0, 6.6, 8.0 MHz) PRF: 2.6 33.3 KHz Multigate HPRF Wall filters: 50 1800 Hz (8 step) Stereophonic audio Sweep Time: 2 16 sec (step 1s) Spectrum: FFT with 128 frequencies, interpolated up to 512 points (analysis time: 1 ms) Sample Size: 1 24 mm
Front End
Transmit Ultrasound beam generation pulses with: Delay: up to 13s (step 12.5 ns) Focal points: up to 8 for every probe Bipolar wave Frequencies: from 1.0 MHz up to 18.0 MHz Programmable number of cycles CW generation capability Programmable aperture Receive Digital beam former RF Signal processing Interpolated data RF lines generation capability Up to 2 digital chain beam for each channel Imaging filters up to 128 taps digital dynamic filter Second Harmonic Imaging (TEI)
Back End
2D Field of view: 30 90 on Phased array Probe depending formats: Phased array, Linear array (with steering), Convex array Depth: 20 360 mm depending on probe Digital scan converter with bilinear interpolation process (640x480x8) Acoustic lines: up to 512 Data dynamic: 8 bit Acoustic frame rate: > 200 Hz (Probe and FOV dependent)
Angle correction : 75 Steering (linear probes): 3 steps (6/12/18) Doppler gain and scale auto-adjustment Real-time Automatic Doppler Measurements (in non cardiac applications) Doppler CW Frequencies: 2.0 5.0 MHz (2.0, 2.5, 3.3, 5.0 MHz) Wall filters: 50 1800 Hz ( 8 step) Data dynamic: 8 bit Stereophonic audio Sweep Time: 2 16 sec (step 1s) Spectrum: FFT with 128 frequencies, interpolated up to 512 points (analysis time: 1 ms) Velocity range: up to 6.42 m/s (@ 2.0 MHz) Angle correction: 75 Echo Process Controls Power: up to 30 dB Imaging compression: 30 60 dB Doppler compression: 20 40 dB Imaging gain: 60 dB (TGC + general) C gain: 30 dB Doppler PW gain: 25 dB Doppler CW gain: 25 dB Pre processing: 16 dynamic shapes in imaging modality Post processing: 5 steps imaging and Doppler Persistence: 8 steps, depending on frame rate ECG Type CF applied part Input impedance: > 10 MOhm (DC) CMMR: > 90 dB (50 Hz) DC max: 300 mV Leakage current: < 10 A Time constant: 3.3 s 10% H.R. detection range: 40 240 bpm
Archiving Capabilities Still image (full resolution) Clip (full resolution) Graphic overlays Reports Offline capability Compressed images and clips Cine Memory: 256 MB (store capacity is 400 frames) continuous loop with different modes (single, dual, split), including Time/ECG triggered loop and frame-by-frame feature PC: 512 MB local drive Hard disk: 250 GB DVD reader/writer Internal patient database User selectable filter for database searches Still image and loop storage in DICOM formats Real-time still frames and video clips Stored data thumbnails always displayed on the side of the screen Measurement and Annotation on stored images IHE Compliant Connectivity I/Os connectors Serial RS-232 LAN RJ45 3 USB (for image transfer) Dedicated connectors Audio input/output (stereo) ECG input Double foot switch External trigger input Image File Formats Standard output: BMP, JPEG, PNG, AVI Native and DICOM Clips characteristics
AVI Codec: Microsoft MPEG4-V2 (highly compressed), MS-WMV9 (improved compatibility) and MS-Video1 (low level compression) Still frames: lossy compressed (about 70% of quality) and not compressed : BMP, JPEG, PNG Graphic overlays Reports Video I/O XVGA output (auxiliary monitor) S-Video (S-VHS) input/output C-Video (VHS) input RGB (TV standard) Video standard: PAL / NTSC (software controlled) Printing Ink jet color or Laser B/W & Color USB Printer (1,2,4 and 6 images printed out on A4 format8.5x11 inch) Thermal B/W and Color Video Printers Thermal Digital B/W and Color Printers Video Requirements RGB Printer Input: RGB SYNC RGB (analog): 0,7 Vp-p, 75 ohm SINC: 5 Vp-p Connectors: Standard BNC Safety standard: IEC 60950 or EN60601-1 B/W Printer Input: Video Composite (1 Vp-p, 75 ohm) Connectors: Standard BNC Safety standard: IEC 60950 or EN60601-1 Video Tape Recorder I/O video: YC Y: 1 Vp-p, 75 ohm C: 0,3 Vp-p Color burst, 75 ohm Tape format: VHS, S-VHS Audio traces: 2
6
Video Conn: 4 pin connector Audio Conn: Jack SINC: 5 Vp-p Safety standard: IEC 60950 or EN60601-1 DICOM Classes DICOM Media Storage DICOM Store SCU DICOM Print DICOM Modality Worklist (MWL) DICOM Modality Performed Procedure Step (MPPS) DICOM Storage Commitment (SC) Software Operating system: WIN XP Embedded Multi-language operation menus (English, Italian, French, German, Spanish) Reports, calculations and measurements (application dependent) Biometry (On/Off-line report) DVD upgrading capability Safety Requirements EN 60601-1 EN 60601-1-1 EN 60601-1-2 EN 60601-1-4 EN 60601-2-37 ENISO 10993-1 EN 61157 AIUM / NEMA UD-2 / UD-3 FDA 510(k) Track 3
Cart Dimensions 51 (W) x 84-106.6 (H) x 65.4 (D) cm Weight 24 kg Power Supply (mains) Voltage operative range: 100 240 V Working frequency range: 50 60 Hz Power consumption: 250 VA Battery Two removable Li-ion batteries Operating time: 1 hour and 20 min Recharging time: 100% = 3 hours and 30 min After 300 cycles remains 80% of maximum charge Nominal operating voltage is 14.4V Capacity: 6.6A Power: 95W Power Cables CEE Socket: 510 IEC 320/C13 type: 10A-250V Plug: VII (7) VII type; 10A-250V Conductors: 3 Section: 1 mm2 Length: 2.5 m CEI Socket: 510 IEC 320/C13 type: 10A-250V Plug: I/3 CEI 23-16 type: 10A-250V Conductors: 3 Section: 1 mm2 Length: 2.5 m NEMA Socket type and amperage: 510 IEC 320/C13 type: 13A-125V Plug type: NEMA 5-15; 13A-125V Conductors: 3
Section: AWG 16 Length: 3 m Operating Requirements Temperature: 15 35C Humidity: 15 95% (not condensing) Pressure: 700 1060 hPa Storage Requirements Temperature: -20 +60C Humidity: 5 95% (not condensing) Pressure: 700 1060 hPa
Generic Measurements
General Imaging The General Imaging license comes standard with the system and enables the abdominal, breast, thyroid, small parts, musculoskeletal, and pediatric applications. B-mode Parameter Distance D-Ratio % Diam Vx-Length Calculation Distance Distance ratio Diameter reduction Length (rectilinear approximation) Length (Profile) Area (Ellipse) Area (rectilinear approximation) Area (Profile) Areas ratio Reduction area Volume (Ellipse) Volume (Profile) Volume (Axes) Measure Distance Two distances Two distances More distances
M-mode Parameter Distance Distance D-Ratio Time % Time HR Velocity % Velocity Doppler Parameter Distance Distance, Area More distances Profile Two areas (on a profile) Two areas (on a profile) Distance, Area Profile, Distance Three distances Time % Time Velocity % Velocity HR FVI PI RI Tr-Flow EI-Flow D-flow Calculation Time Time ratio Velocity Velocity ratio Heart rate Vascular FVI Pulsatility index Resistive index Flow (Profile) Flow (Ellipse) Flow (Diameter) Measure Time Two times Velocity Two velocities Time Spectral envelope Spectral envelope Two velocities Velocity, Profile Velocity, Profile Velocity, Distance Calculation Distance Distance Distance ratio Time Time ratio Heart rate Velocity Velocity ratio Measure Distance Distance Two distances Time Two Times Distances Velocity Two velocities
Vascular The Vascular imaging license comes standard with the system. B-mode Parameter Distance D-Ratio % Diam Tr-Area A-Ratio % Area Velocity % Velocity M-mode Parameter Distance D-Ratio Time % Time HR Velocity % Velocity % Velocity Calculation Distance Distance ratio Time Time ratio Heart rate Velocity Velocity ratio Velocity ratio Measure Distance Two distances Time Two times Distances Velocity Two velocities Two velocities Calculation Distance Distance ratio Diameter reduction Area (Profile) Areas ratio Area reduction Velocity Velocity ratio Measure Distance Two distances Two distances Profile Two areas (on a profile) Two areas (on a profile) Velocity Two velocities
Doppler Parameter Time % Time Velocity % Velocity HR FVI PI RI Tr-Flow EI-Flow D-Flow Calculation Time Time ratio Velocity Velocity ratio Heart rate Vascular FVI Pulsatility index Resistive index Flow (Profile) Flow (Ellipse) Flow (Diameter) Measure Time Two times Velocity Two velocities Time Spectral envelope Spectral envelope Two velocities Velocity, Profile Velocity, Profile Velocity, Distance
Cardiology The Cardiology imaging license is an option purchase. Advanced measurements and reporting can be found in the operations manual. B-mode Parameter Distance Tr-Area Tr-Volume E-Ratio Calculation Distance Area (Profile) Volume (Profile) Area ratio Measurement Distance Profile Profile, Distance Two areas (ellipse based)
M-mode Parameter Distance HR Velocity Calculation Distance Heart rate Velocity Measurement Distance Time Velocity
Doppler Parameter Time Velocity HR C-FVI Slope OB-Fetal The OB imaging license is an optional purchase. Advanced measurements and reporting can be found in the operations manual. B-mode Parameter Distance D-Ratio Vx-Length Calculation Distance Distance ratio Length (approximately straight) Length (Profile) Area (Ellipse) Area (approximately straight) Area (Profile) Areas ratio Volume (Ellipse) Volume (Profile) Volume (Axes) Area ratio Measure Distance Two distances More distances Calculation Time Velocity Heart rate FVI Slope Measurement Time Velocity Time Spectral envelope Slope
M-mode Parameter Distance D-Ratio Time % Time HR Velocity % Velocity Doppler Parameter Time % Time Velocity % Velocity HR C-FVI Distance Distance, Area More distances PI RI Profile Two areas (on a profile) Distance, Area Profile, Distance Three distances Two areas (ellipse based) D-Flow D-Flow Flow (diameter) Flow (Diameter) Tr-Flow EI-Flow Pulsatility index Resistive index Flow (Profile) Flow (Ellipse) FVI Calculation Time Time ratio Velocity Velocity ratio Heart rate FVI Vascular VI Measure Time Two times Velocity Two velocities Time Spectral envelope Spectral envelope Spectral envelope Two velocities Velocity, Profile Velocity, Profile Velocity, Distance Velocity, Distance Calculation Distance Distance ratio Time Time ratio Heart rate Velocity Velocity ratio Measure Distance Two distances Time Two times Distance Velocity Two velocities
10
TRANSDUCERS
ACUSON P300 system supports the following transducers and applicable intended clinical use: ABD Curved Array CA123 CA431 Linear Array LA435 LA522 LA523 Phased Array PA023 PA122 PA230 Specialty EC1123 IOE323 LP323 Doppler 2CW 5CW AC BRE CAR CP GYN MSK NC OB PED SP THY VAS
ABD: Abdominal; AC: Adult Cephalic; BRE: Breast; CAR: Cardiac; CP: Cardiac Pediatric; GYN: Gynecologic; MSK: Musculoskeletal conventional and superficial; NC: Neonatal; OB: Obstetric; PED: Pediatric; SP: Small Parts; THY: Thyroid; VAS: Vascular.
11
B-mode, M-mode Selectable Frequencies: 5.0, 7.5, 10.0, 12.0 MHz TEI Frequencies: Penetration and Resolution C Doppler, PW Doppler Selectable Frequencies: 3.3, 5.0 MHz Steered angle: 7 steps Biopsy: Multi angle reusable autoclave sterilized adaptor LA435 Technology: Wideband Electronic Linear Array Number of elements: 192 Depth: 0 90 mm Footprint: 40 mm x 5 mm Frequency Bandwidth: 6.0 18.0 MHz B-mode, M-mode Selectable Frequencies: 10.0, 12.0, 15.0, 18.0 MHz TEI Frequencies: Penetration and Resolution C Doppler, PW Doppler Selectable Frequencies: 6.6, 8.0 MHz Steered angle: 7 steps Biopsy: Multi angle reusable autoclave sterilized adaptor LA523 Technology: Wideband Electronic Linear Array Number of elements: 192 Depth: 0 120 mm Footprint: 50 mm x 8 mm Frequency Bandwidth: 4.0 13.0 MHz B-mode, M-mode Selectable Frequencies: 7.5, 10.0, 12.0 MHz TEI Frequencies: Penetration and Resolution C Doppler, PW Doppler Selectable Frequencies: 5.0, 6.6 MHz Steered angle: 7 steps Biopsy: Multi angle reusable autoclave sterilized adaptor, disposable kit
Phased Array Probes PA230 Technology: Wideband Electronic Phased Array Number of elements: 128 Depth: 0 360 mm Footprint: 14 mm x 23 mm Field of view: 15 90 Frequency Bandwidth: 1 4 MHz B-mode, M-mode Selectable Frequencies: 2.0, 2.5, 3.5 MHz TEI Frequencies: General, Penetration, Resolution Color Doppler, PW Doppler Selectable Frequencies: 2.0, 2.5 MHz Biopsy: Not Available PA122 Technology: Wideband Electronic Phased Array Number of elements: 128 Depth: 0 270 mm Foot print: 10 mm x 16 mm Field of view: 15 90 Frequency Bandwidth: 3.0 8.0 MHz B-mode, M-mode Selectable Frequencies: 4.0, 5.0, 7.5 MHz TEI Frequency: NA C Doppler, PW Doppler Selectable Frequencies: 3.3 5.0 MHz Biopsy: Not Available PA023 Technology: Wideband Electronic Phased Array Number of elements: 128 Depth: 0 270 mm Foot print: 6 mm x 13 mm Field of view: 15 90 Frequency Bandwidth: 4.0 11.0 MHz B-mode, M-mode Selectable Frequencies: 7.5, 10.0 MHz TEI Frequencies: NA
Color Doppler, PW Doppler Selectable Frequencies: 5.0 MHz Biopsy: Not Available Specialty Probes EC1123 Technology: Wideband Electronic end fire microConvex Number of elements: 192 Depth: 0 170 mm Footprint: 13 10 mm radius Field of view: 30 195 Frequency Bandwidth: 3.0 9.0 MHz B-mode, M-mode Selectable Frequencies: 4.0, 5.0, 6.6, 8.0 MHz TEI Frequencies: Resolution C Doppler, PW Doppler Selectable Frequencies: 5.0, 6.6 MHz Biopsy: Single and disposable use adaptor IOE323 Application: Intraoperative Technology: Wideband Electronic Linear Array Depth: 0 90 mm Footprint: 30 mm Frequency Bandwidth: 4.0 13.0 MHz B-mode, M-mode Selectable Frequencies: 5.0, 7.5, 12.0 MHz TEI Frequencies: Penetration and Resolution C Doppler, PW Doppler Selectable Frequencies: 5.0, 6.6 MHz Biopsy: Multi angle reusable autoclave sterilized adaptor
13
LP323 Application: Laparoscopic Technology: Wideband Electronic Linear Array Depth: 0 90 mm Frequency Bandwidth: 4.0 13.0 MHz B-mode, M-mode Selectable Frequencies: 5.0, 7.5, 12.0 MHz TEI Frequencies: Penetration and Resolution C Doppler, PW Doppler Selectable Frequencies: 5.0, 6.6 MHz Articulation up/down 90 Articulation right/left 90 Biopsy: Not Available Non Imaging Pencil probe 2 MHz CW Doppler Number of elements: 2 C Doppler, PW Doppler Frequencies: 2.0 MHz 5 MHz CW Doppler Number of elements: 2 C Doppler, PW Doppler Frequencies: 5.0 MHz
Disposable Needle Guides by Protek1 All kits are provided with 1223 gauge needle guides. Each kit contains sterile probe covers, sterile needle guides, sterile gel and sterile elastic bands plus a non-sterile mounting bracket and a non-sterile verification kit. The sterile needle guides are of different colors to match the needle to be used. The needle guides are sterile, but, they cannot be re-sterilized. Probe CA123 CA431 LA435 LA522 LA523 EC1123 Fixed Angle 15 20 30 45 45 60 75 0 6360 7351 Manufacturers Kit P/N 7356 7352 7350
Disposable Needle Guides by CIVCO2 Fixed Angle and Multi-Angle Kits All kits are provided with 1223 gauge needle guides. Each kit contains sterile probe covers, sterile needle guides, sterile gel and sterile elastic bands plus a non-sterile mounting bracket and a non-sterile verification kit. The needle guides are sterile, but, they cannot be re-sterilized.
Biopsy Kits
The following kits are available: Biopsy adaptor ABS421 Probe CA431 Kit contents 1 20 coupling, 1 30 coupling+ 5 needle guides 1 coupling (45 angle) + 5 needle guides 1 coupling (45 angle) + 5 needle guides 1 coupling (45 angle) + 5 needle guides
1 2
www.protekmedical.com www.civcomedical.com
14
Probe
CA123
CA431
639-018
LA435
60 70 40
639-023
55 70
639-022
610-693 639-012
Free Insertion Angle Kits The Infinity needle guide kits listed in the table below allow the user to have a free insertion angle: this can be any angle within the range edged by the guide back wall, on one side, and by the transducer itself, on the other side. The kit allows the user to keep the needle on the same scanning plane of the probe. All kits are provided with 14 and 18 gauge needle guides. Each kit contains sterile probe covers, sterile needle guides, sterile gel and sterile elastic bands plus a non-sterile mounting bracket and a non-sterile verification kit. The needle guides are sterile but cannot be re-sterilized. Probe Insertion Angle Range Manufacturers Kit P/N CA431 LA435 LA522 LA523 42 64 42 80 42 80 639-014 639-021 639-016
15
ACUSON and P300 are trademarks of Siemens Medical Solutions USA, Inc. DS 0712 I 7.2012, Siemens Medical Solutions USA, Inc.
Global Siemens Healthcare Headquarters Siemens AG Healthcare Sector Henkestrasse 127 91052 Erlangen Telephone: +49 9131 84-0 Germany www.siemens.com/healthcare
Legal Manufacturer Siemens Medical Solutions USA, Inc. Ultrasound 685 E. Middlefield Road Mountain View, CA 94043 USA Telephone: +1-888-826-9702 www.siemens.com/ultrasound
A91US-218-IC-4A00