Standard
High reliability is realized!
(1)
specifications
The FR-D700 series is compliant to the EU Machinery Directive without the addition of previously required external devices. Operation of an external Emergency Stop device results in a highly reliable immediate shutoff of the D700's output to the motor. This safety stop function conforms to the following standards.
EN954-1 (ISO13849-1) Category 3 IEC60204-1 Stop Category 0
150%/1Hz high starting torque by general -purpose magnetic flux vector control
(2)
Outline
dimension drawings
Emergency stop
Emergency stop
General-purpose magnetic flux vector control and auto tuning function are available. It ensures operation that requires high starting torque, such as transfer machine including conveyer, hoist, lift, etc., washing machine, and agitators. High torque 150%/1Hz and 200%/3Hz are realized Auto tuning Many kinds of motors can be optimally controlled with Mitsubishi original "non-rotation " auto tuning function. (R1 constants tuning)
A brake transistor is built-in to the 0.4K or more. Connecting an optional brake resistor increases regeneration capability. It is useful for deceleration time reduction of a machine with a large inertia, such as fan, and operation of lift, etc.
Terminal connection
diagram
Terminal specification
explanation
11
Parameter list 16
Protective
(2)
functions
23
Highly reliable and easy wiring is realized by the incorporation of spring clamp terminals.*
*: Main circuit terminal is screw terminal.
(3)
Enhanced function
failure-time deceleration-to-stop function Power The motor can be decelerated to a stop when a power
failure or undervoltage occurred to prevent the motor from coasting. For fail-safe of machine tool, etc., it is effective to stop the motor when a power failure has occurred.
Option and
peripheral devices
24
New functions and useful functions from superior models support all sorts of applications.
(example: hoist)
Precautions for
operation/selection
27
FR-D700 Series
Specification Difference List
32
(3)
Long-life design
(4)
Warranty International
FA Center
(example: spindle)
33
(5)
Password function
*3: Excerpts from "Periodic check of the transistorized inverter" of JEMA (Japan Electrical Manufacturers Association)
Registering 4-digit password can limit parameter read/write. It is effective for parameter setting protection.
(1)
(1)
(2)
(4)
(1)
(3)
(3)
*: This catalog explains based on the Japanese specifications. Consult our sales office for specifications of each country.
F R-D 740
-0. 4K -
Symbol 1 2 4
Symbol None S W
Number of Power Phases Three-phase input Single-phase input Single-phase input (double voltage output)
Symbol None C
(1)
(2)
Power Supply
Three phase 200V Three phase 400V Single phase 200V *
Inverter Type
FR-D720- K FR-D740- K FR-D720S- K FR-D710W- K
Inverter Capacity
Enclosed structure (IP20) Totally-enclosed structure (IP40) Enclosed structure (IP20) Totally-enclosed structure (IP40) Enclosed structure (IP20) Enclosed structure (IP20)
0.1
0.2
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
Installation size is the same as that of the FR-S500 series which is the smallest model of the Mitsubishi inverter.
128mm
*: Output of the single-phase 200V and single-phase 100V input models is three-phase 200V.
:Available models
:Models to be released
:Not available
FR-D740-0.4K
FR-S540E-0.4K
(5)
Instructions
The lineup of three phase 200V/400V class goes to 15K. For the FR-D700 series, North American (NA), EU (EC), and Chinese (CHT) specifications also are supported.
Options
Protective Functions
Parameter List
Connecting a personal computer and the inverter via RS-485 communication realizes setting with wizard (interactive) function of the FR Configurator (inverter setup software). In addition, a parameter setting can be converted from the FRS500 series to the FR-D700 series by "convert" function. Displays monitor data in waveform. [Graph]
The operation panel of the inverter can not be removed. A parameter unit connection cable (FR-CB20 ) is separately necessary.
Optional enclosure surface operation panel (FR-PA07) can be connected. In addition, an operation panel for the FR-E500 series can be connected.
(2)
Setting is easily done from a personal computer using the FR Configurator (option) (available soon)
(3)
Standard Specifications
Mitsubishi inverter has a setting dial of course. The scrolling speed of the dial was made to variable for more improved operability. The nonslip setting dial is easier to turn.
A cooling fan is provided on top of the inverter of all capacities requiring a cooling fan (1.5K or more). A cooling fan can be easily replaced without disconnecting main circuit wires.
Since a cover can be fitted after wiring, wiring work is easily done.
Features
Standard specifications
Rating