Model
Standby power Prime power
KV80
72 64
KV90E
kW / 90 kVA kW / 80 kVA
STANDARD CONFIGURATION
VOLVO PENTA engine TD520GE STAMFORD alternator Radiator Base fuel tank with an 8-hours capacity at full load and high efficiency anti-vibration materials 12V batteries ABB circuit breaker Manual control system Installation and operation manual
Generator rating
Voltage 415/240 400/230 380/220 220/127 220 110 480/277 440/254 416/240 220/127 220 110 Hz 50 50 50 50 50 50 60 60 60 60 60 60 Max. power 83 83 83 83 83 83 85 85 85 85 85 85 Phase 3 3 3 3 1 1 3 3 3 3 1 1 P.F 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Standby Ratings (kW/kVA) 72/90 72/90 72/90 72/90 72/90 72/90 77/96 77/96 77/96 77/96 77/96 77/96 Prime Ratings (kW/kVA) 64/80 64/80 64/80 64/80 64/80 64/80 70/88 70/88 70/88 70/88 70/88 70/88 Max. Current (A) 125 130 137 236 409 818 115 126 133 252 436 873
The above information is only for reference purpose and shall constitute no restraint to us. No further notice shall be given upon any change of the information, We reserve the authority for final revision.
ENGINE
General Data Model Number of cylinders Bore and stroke --(mm) Displacement--(L) Starting system Exhaust System Exhaust flow--(m3/min) Exhaust temperature--() Fuel System Recommended fuel Governor Type Max fuel transfer pump suction--(m) Base fuel tank--(L) Oil System Oil system capacity--(L) Recommended oil 13 API-CD OR BETTER Oil normal temperature--() Oil consumption load--(l/h) at 100% 80 0.06 ASTM NO.2-D Mechancial 0.9 350 Fuel consumption--(l/h) 25% Power 50% Power 75% Power 100% Power Prime 4.0 8.5 12.5 16.0 Standby 4.5 9.5 13.5 18.0 15.4 610 Allowable restriction--(kPa) Exhaust pipe diameter--(mm) 3 100 TD520GE 4 108*130 4.76 DC12V Compression ratio Combustion system Engine type Aspiration Rated RPM 17.5:1 Direct Injection In-line, 4-cycle Turbocharged 1500/1800
Air System Air consumption--( m3/min) Cooling System Radiator and capacity--(L) Fan power--(kW) Fan Air flow--(m /min) Physical Data Length--(mm) Height--(mm) Width--(mm) Weight, dry--(kg) 550
3
4.75
engine
22 2.5 90
82-94 98 glycol
The above information is only for reference purpose and shall constitute no restraint to us. No further notice shall be given upon any change of the information, We reserve the authority for final revision.
ALTERNATOR
General Data Compliance with GB755, BS EN60034, BS5000, VDE0530, NEMA MG1-32, IEC34, CSA C22.2-100, AS1359 Alternator Data Manufacturer Control System Insulation class Temperature Rise Rated Power Facror Winding Pitch Voltage adjust scope Weight--(kg) NEWAGE STAMFORD Self Excited and Brushless H H 0.8 Two Thirds 6% 350 Model A.V.R. Protection Stator Winding Winding Leads Voltage regulation Bearing number Cooling Air--(m /sec)
3
Control Panel
Manual Control Panel
Specifications: Manual start Voltage , Current , Frequency , Battery voltage , Hour meter , Charger Alternator Voltage and Speed(R.P.M) can be displayed by means of LEDs Emergency stop pushbutton The LED indicators for the display of engine fault status: Low Fuel Level Emergency Alarm Low Oil Pressure High Temperature High/Low Battery Voltage Belt Break/Charger Failure Over/Under Speed Over/Under Overload
The above information is only for reference purpose and shall constitute no restraint to us. No further notice shall be given upon any change of the information, We reserve the authority for final revision.
The above information is only for reference purpose and shall constitute no restraint to us. No further notice shall be given upon any change of the information, We reserve the authority for final revision.
Options
Engine
Jacket water heater Fuel water separator Heavy duty air filter Coolant level alarm
Control panel
Auto control panel Remote control panel Digital Paralleling control panel Dampproof heater
Alternator
Leroy Somer alternator Anti-condensation heater PMG or auxiliary windings
Fuel
Daily tank Fuel water separator Fuel level alarm
Enclosure
Canopy Trailer Mobile power station
Exhaust
Residential silencer
Spare part
Oil filter / Fuel filter / Air filter
SOUNDPROOF GENSETS
Noise deduction in compliance with ISO3744 Superb ventilation system and anti-thermal radiation measures ensuring proper operation without power loss Base fuel tank with extraordinary capacity Adoption of special noise reduction materials and high efficiency anti-vibration materials to minimize the noise Observation window and emergency stop button on the enclosure for easier monitoring and operation
Canopy model
Canopy size (LWH)--(mm) Weight--(kg) 305011001850 1914