EPL Lab Manual
EPL Lab Manual
EPL Lab Manual
LABORATORY MANUAL
LABORATORY PRACTICE
SAFETY RULES
1. SAFETY is of paramount importance in the Laboratories. 2 .Electricity NEVER EXECUSES careless persons. So, exercise enough care and
attention in handling electrical & electronic equipment and follow safety practices in the laboratory. (Electricity is a good servant but a bad master). 3. Avoid direct contact with any voltage source and power line voltages. (Otherwise,
any such contact may subject you to electrical shock) 4. Wear rubber-soled shoes. (To insulate you from earth so that even if you accidentally
contact a live point, current will not flow through your body to earth and hence you will be protected from electrical shock) . 5. Wear laboratory-coat and avoid loose clothing. (Loose clothing may get caught on
an equipment/instrument and this may lead to an accident particularly if the equipment happens to be a rotating machine) 6. 7. Girl students should have their hair tucked under their coat or have it in a knot. Do not wear any metallic rings, bangles, bracelets, wristwatches and neck chains.
(When you move your hand/body, such conducting items may create a short circuit or may touch a live point and thereby subject you to electrical shock) 8. Be certain that your hands are dry and that you are not standing on wet floor. (Wet
parts of the body reduce the contact resistance thereby increasing the severity of the shock) 9. Ensure that the power is OFF before you start connecting up the circuit.(Otherwise you
will be touching the live parts in the circuit) 10. Get your circuit diagram approved by the staff member and connect up the circuit 2
Check power chords for any sign of damage and be certain that the chords use
safety plugs and do not defeat the safety feature of these plugs by using ungrounded
When using connection leads, check for any insulation damage in the leads and
avoid such defective leads. 13. Switch on the power to your circuit and equipment only after getting them checked up
and approved by the staff member. 14. .Do not make any change in the connection without the approval of the staff
member. 15. In case you notice any abnormal condition in your circuit ( like insulation heating
up, resistor heating up etc ), switch off the power to your circuit immediately and inform the staff member. 16. 17. Keep hot soldering iron in the holder when not in use. After completing the experiment show your readings to the staff member and
switch off the power to your circuit after getting approval from the staff member. 18. Some students have been found to damage meters by mishandling in the following ways: i. ii. Keeping unnecessary material like books, lab records, unused meters etc. causing meters to fall down the table. Putting pressure on the meter (specially glass) while making connections or while talking or listening somebody.
NOTES
1. The students will be split in batches. After splitting the batches they should do the experiments only with their batch members till the end of semester unless there is a change made by the staff. They should not mingle with other batch mates unless the staff asks them to do so. 2. Manual is only for the reference purpose. The experiments reading should be noted down only in the observation notebook. 3. The students should maintain an observation note book separately which should be brought to every lab class without fail. No students will be allowed to enter the lab class without observation note book and record note book. 4. The experiments will be splitted up as Cycle-I & Cycle-II. The students must write well in advance all the experiments of that particular cycle of which they are going to begin. 5. The students must come to lab class by preparing for the particular experiment they do for that day and the experiment should well be written in the observation before they come to the lab class. 6. Each experiment will be awarded an assessment marks. Total of 10 marks will be assigned as assessment mark for each experiment out of which 5 marks will be awarded based on the number of days of which the students gets their experiment corrected in the observation notebook. The mark will be awarded as follows: Getting signed on the day of experiment - 5 Marks 1 day from the day of experiment 2 days from the day of experiment 3 days from the day of experiment 4 days from the day of experiment 5 days from the day of experiment - 5 Marks - 4 Marks - 3 Marks - 2 Marks - 1 Mark
These days are exclusive of Sundays and public holidays. After 5 days no observation will be signed by the staff member.
The remaining 5 marks will be awarded based on how the student he/she answers the Viva- Voice question which will be asked at the beginning and end of each experiment. 7. The students can get sign in the observation note book only from the in charge staff or from assist staff. 8. If the student does not get the particular experiment signed on the observation, they should not write that particular experiment in their record notebook and they will also not be given any assessment marks for that particular experiment. 9. The circuit diagrams should be drawn only using HB pencil, Scale, Pro circle, etc. No rough diagrams are entertained. 10. At the end of each experiment completed on that particular day Viva Voice questions will be asked by the staff members. The Viva voice questions can be from any part of that particular subject. 11. No student should take leave on the day of Lab class unless for the case of emergency. In case they absent themselves, the particular student he/she will not be allowed to repeat the experiment for which they absent. 12. The Student who absent themselves for the lab class will be allowed to enter the lab only after getting their leave form signed from the Class In charge and the HOD of their respective department. 13. No repetition classes for any student will be allowed unless the staff asks them to do so.
The laboratory notebook is a record of all work pertaining to the experiment. This record should be sufficiently complete so that you or anyone else of similar technical background can duplicate the experiment and data by simply following your laboratory notebook. Record everything directly into the notebook during the experiment. Do not use scratch paper for recording data. Do not trust your memory to fill in the details at a later time. Organization in your notebook is important. Descriptive headings should be used to separate and identify the various parts of the experiment. Record data in chronological order. A neat, organized and complete record of an experiment is just as important as the experimental work. 1. Heading: The experiment identification (number) should be at the top of each page. Your name and date should be at the top of the first page of each day's experimental work. 2. Object: A brief but complete statement of what you intend to find out or verify in the experiment should be at the beginning of each experiment 3. Diagram: A circuit diagram should be drawn and labeled so that the actual experiment circuitry could be easily duplicated at any time in the future. Be especially careful to record all circuit changes made during the experiment. 4. Equipment List: List those items of equipment which have a direct effect on the accuracy of the data. It may be necessary later to locate specific items of equipment for rechecks if discrepancies develop in the results. 5. Procedure: In general, lengthy explanations of procedures are unnecessary. Be brief. Short 6
commentaries along side the corresponding data may be used. Keep in mind the fact that the experiment must be reproducible from the information given in your notebook. 6. Data: Think carefully about what data is required and prepare suitable data tables. Record instrument readings directly. Do not use calculated results in place of direct data; however, calculated results may be recorded in the same table with the direct data. Data tables should be clearly identified and each data column labeled and headed by the proper units of measure. 7. Calculations: Not always necessary but equations and sample calculations are often given to illustrate the treatment of the experimental data in obtaining the results. 8. Graphs: Graphs are used to present large amounts of data in a concise visual form. Data to be presented in graphical form should be plotted in the laboratory so that any questionable data points can be checked while the experiment is still set up. The grid lines in the notebook can be used for most graphs. If special graph paper is required, affix the graph permanently into the notebook. Give all graphs a short descriptive title. Label and scale the axes. Use units of measure. Label each curve if more than one on a graph. 9. Results: The results should be presented in a form which makes the interpretation easy. Large amounts of numerical results are generally presented in graphical form. Tables are generally used for small amounts of results. Theoretical and experimental results should be on the same graph or arrange in the same table in a way for easy correlation of these results. 10. Conclusion: This is your interpretation of the results of the experiment as an engineer. Be brief and specific. Give reasons for important discrepancies.
value or one that doesnt work. It is also possible that the equipment does not work (although this is not probable) or the protoboard you are using may have some unwanted paths between nodes. To find your problem you must trace through the voltages in your circuit node by node and compare the signal you expect to have. Then if they are different use your engineering judgment to decide what is causing the different or ask your lab assistant
List Of Experiments Group B (Elect rical & Electronics) Electrical Engineering Practice 1. Residential house wiring using switches, fuse, indicator, lamp and energy 8
meter. 2. Fluorescent lamp wiring. 3. Stair case wiring. 4. Measurement of electrical quantities voltage, current, power & power factor in RLC circuit. 5. Measurement of energy using single phase energy meter. 6. Measurement of resistance to earth of electrical equipment. Electronics Engineering Practice Study of Electronic components and equipments Resistor, colour coding .
1.
Study of logic gates AND, OR, EX-OR and NOT. Generation of Clock Signal.
Soldering practice Components Devices and Circuits Using general purpose PCB.
6.
(a) Measurement of ripple factor of Half Wave Rectifier. (b)Measurement of ripple factor of. Full Wave Rectifier.
1.
Residential house wiring using switches, fuse, indicator, lamp and energy meter. Fluorescent lamp wiring Stair case wiring. Measurement of electrical quantities voltage, current, power & power factor in RLC circuit. Measurement of energy using single phase energy meter. Measurement of resistance to earth of electrical equipment.
1.
11 16 20 23
2. 3. 4.
5.
27
6.
31
Study of Electronic components and equipments Resistor, colour coding . Measurement of AC signal parameter (peakpeak, rms period, frequency)using CRO.
35
2.
37
3.
Study of logic gates AND, OR, EX-OR and NOT Generation of Clock Signal. Soldering practice Components Devices and Circuits Using general purpose PCB. Measurement of ripple factor of Half Wave Rectifier.
41 45
4. 5.
49
6.a.
52
6.b .
56
Ex. No.1
10
RESIDENTIAL HOUSE WIRING USING SWITCHES, FUSE, INDICATOR LAMP AND ENERGY METER
AIM:To make a simple residential house wiring using switches, fuse, indicator lamp, filament lamps and energy meter. APPARATUS REQUIRED: Wiring Board Connecting Wires Switches-2 Lamps-2 Fuse-1 Indicator lamp-1 Energy meter-1 3 pin socket-1
THEORY:A switch is used to make or break the electric circuit. It must make the contact finely. Under some abnormal conditions it must retain its rigidity and keep its alignment between switch contacts. Different types of switches are as follows. 1. Surface or Tumbler switch a. Single way switch b. Two way switch 2. Flush Switch 3. Pull or Ceiling switches 4. Rotary snap switches 5. Push button switch 6. Iron- Clad watertight switches The fuse arrangement is made to break the circuit in the fault or overloaded conditions. The energy meter is measuring the units (KWhr) consumed by the various loads. 11
CIRCUIT DIAGRAM
12
LAYOUT DIAGRAM:\
13
PROCEDURE:1. Mark the lamp and switch positions. 2. Give the connections as per the circuit diagram. 3. Switch on the supply. 4. Check the lamps are glowing or not when the corresponding switches are kept in the ON position. 5. Check whether the energy meter responding to the load.
RESULT:Thus the simple house wiring by using switches, fuse, indicator, filament lamps and energy meter was studied.
14
VIVA QUESTIONS:
1. What is the purpose of neutral in the circuit? 2. What kind of supply is given to the circuit? 3. What is the supply for single phase? 4. What is the purpose of fuse in a circuit? 5. What is series and parallel connection of components? 6. What is DPSTS? 7. What is an energy meter? 8. What is frequency? 9. What is AC supply? 10. Name the three pins in a three pin socket?
15
Ex. No.2
AIM:
STAIRCASE WIRING
To study the working principle of staircase Wiring APPARATUS REQUIRED: S.No 1 2 3 4 5 Name of the Components Lamp Two way Switch Screw Driver Lamp holder Connecting wires Range 60W Quantity 1 2 1 1
16
Procedure: 1. 1.Mark switch and bulb location points and draw lines for wiring on the wooden board. 2. Place wires along the lines and fix them with the help of clamps. 3. Fix the two-way switches and bulb holder in the marked positions on the wooden board. 4. Complete the wiring as per the wiring diagram. 5. Test the working of the bulbs by giving electric supply to the circuit.
17
Viva Questions: 1. What is the type of switch using in this experiment? 2. What are the applications? 3. What is the difference between 1-way and 2-way switch? 4. What is the use of this wiring?
18
Ex. No.3
AIM:
To prepare wiring for a fluorescent lamp with switch control. TOOL REQUIRED: 1. Screw driver 2. Hammer 3. Cutting Plier 4. Line tester COMPONENTS REQUIRED: 1. Switch 2. Tube light with fitting 3. Joint clips 4. Wires 5. Screws 6. Switch board
19
LAYOUT DIAGRAM:
20
THEORY: The fluorescent lamp circuit consists of a choke, starter, a fluorescent tube and a frame. The length of the commonly used fluorescent tube is 100cm and its power rating is 40W and 230V. The tube is filled with argon and a drop of mercury. When the supply is switched on, the current heats the filaments and initiates emission of electrons. After one or two seconds, the starter circuit opens and makes the choke to induce a momentary high voltage surge across the two filaments. Ionization takes place through argon and produces bright light.
PROCEDURE: 1. Mark the switch and tube light location points and draw lines for wiring on the wooden board. 2. Place wires along the lines and fix them with the help of clips. 3. Fix the switch and tube light fitting in the marked positions. 4. Complete the wiring as per the wiring diagram 5. Test the working of the tube light by giving electric supply to the circuit.
RESULT: The wiring for the tube light was completed and tested. 21
VIVA QUESTIONS: 1. 2. 3. 4. 5. What are the gases filled in the fluorescent tube. What is the use of choke? Why is starter used in fluorescent tube? Will the tubelight glow if the starter is removed after the tubelight is on? What is the material used for coating the tubelight?
22
Formula used: 1. Actual value of power = Observed value X Multiplication factor 2. Actual power = VI Cos Watts Where, V-Voltmeter reading I - Ammeter reading 3. Power factor Cos = Actual power / Voltmeter reading X Ammeter reading(VI)
(0-10) A MI 10 A
M P
C V
(0-300)V MI
10 A
Tabular Column Multiplication factor = Wattmeter reading (Watts) Observed Value Actual value
S.No
Voltage (Volts)
Current (Amp)
Procedure: 1. The circuit connections are made as per the circuit diagram. 24
2. Initially no load is applied 3. The autotransformer is varied to the rated voltage. 4. The values of voltmeter, ammeter and wattmeter on no load condition is noted. 5. By varying the load in steps the corresponding readings of ammeter, voltmeter and wattmeter are noted. 6. Then the value of power factor is calculated.
Result: Thus the power in the circuit was measured by the wattmeter and the % error was calculated.
VIVA QUESTIONS
25
1. Define Voltage and Current? 2. Define power and power factor? 3. What is an auto-transformer? 4. Define multiplication factor? 5. What is the use of wattmeter? 6. What is the difference between transformer and an auto transformer?
Aim: To measure the electrical energy in a single phase AC circuit with the help of a single-phase energy meter. Apparatus required: S.NO 1 2 3 4 5 6 Formula 1. Actual power = VI cos watts. Where V-voltmeter reading, I-ammeter reading, assume power factor cos = 1 2. K revolutions = 1kwhr ie K = 1000*3600 watt seconds ..(1) 3. (n revolutions/m seconds) = P watts So n = P*m .(2) From equations (1) & (2) K/n = (1000*3600)/(P*m) 4. Power consumed , P = (n*1000*3600)/(m*K) Where n Number of Revolutions, Say10 m Time Taken For n Revolutions K Energy Meter Constant COMPONENT Single phase autotransformer Single phase energy meter Voltmeter Ammeter Connecting wires Lamp load TYPE KVA MI MI RANGE (0-300)V 230V,5A,900rev/Kwhr (0-300)V (0-5)A 5A QUANTITY 1 1 1 1 1
27
Tabular Column: S.No Voltage (Volts) Current (Amp) Time taken for n rev (sec) Actual power calculated ws Energy Consumed
THEORY: 28
Energy meter is a device used to measure the energy consumed in AC circuits. It has two electromagnetic coils made of silicon steel. This two coils are called current coil and pressure coil. An aluminium disc revolution it due to the torque produced as a result of the flux that is propotional to the current and supply voltage. The number of revolutions of the disc per kwhr is shown on the energy meter and is called energy meter constant (K). IN an energy meter K revolutions are equal to 1kwhr.
Procedure: 1. The circuit connections are made as per the circuit diagram. 2. Initially no load is applied 3. Auto transformer is set to minimum voltage position before switch ON the Power supply. 4. The autotransformer is varied to the rated voltage (230V). 5. The values in the voltmeter, ammeter are recorded. Also the taken for n revolutions (say10) on the energy meter disc is noted. All the values are noted on no load condition. 6. The load is applied by switching on the lamp ON. 7. The voltmeter and ammeter time taken for n revolutions on the energy meter disc readings are noted. 8. Steps 6 & 7 are repeated by switch on more lamps one by one reaches 5A. 9. After noting all the readings, the load is reduced to minimum and auto transformer is also reduced to minimum. Power supply is switched OFF.
Result: Thus the energy is measured using energy meter in the given circuit.
2. What is the use of Energy meter? 3. What are the two coils used in Energy meter ? 4. What is pressure coil? 5. What is current coil? Why it is used? 6. What is Actual power? Give the formula. 7. What is the use of auto transformer? 8. Give the difference between auto transformer & ordinary transformer ? 9. Define power? Give formula for power consumed.
Aim: To measure the resistance to earth / insulation resistance of the order of mega ohms. Theory: Megger is an instrument for testing the insulation resistance of the order of mega ohms. It consists of an emf source and a voltmeter. The voltmeter scale is calibrated in ohms. In measurement, the emf of the self-contained source should be equal that of the source used in calibration. The deflection of the moving system depends on the ratio of the currents in the coils and is independent of the applied voltage. The value of unknown resistance can be found directly from the scale of the instrument. Figure shows detailed diagram of a megger. It consists of a hand driven dc generator a emf about 500v.the permanent dc meter has two moving coils. First one is deflecting coil and another another one is controlling coil. The deflecting coil is connected to the generator through a resistor R2 . The torque due to the two coils oppose each other. It consists of three terminals E (earth terminal ) and L (line terminal) and G (guard wire terminal). MEGGER
31
TABULAR COLOUMN
S.NO
32
Operation: When the terminals are open circuited, no current flows through the deflecting coil. The torque to the controlling coil moves the pointer to one end of the scale. When the terminals are short circuited, the torque due to the controlling coil and the pointer is deflected to the other end of the scale i.e. zero mark. In between the two extreme positions the scale is calibrated to indicate the value of unknown resistance directly. The unknown insulation resistance is the combination of insulation volume resistance and surface leakage resistance. The guard wire terminal makes the surface leakage current to by pass the instrument hence only insulation resistance is measured. Procedure: 1. Connections are given as per the connection diagram. 2. Insert the rods at two different places in the ground and supply the desired voltage to megger for its operation by rotating the handle. 3. Take the readings of the megger. 4. Repeat the steps 3 and 4 by varying the distance between the rods.
Result: Thus the measured value of the resistance to earth / insulation resistance of the unknown material is = ----- M
33
VIVA QUESTIONS: 1. What is the instrument used for finding earth resistance? 2. What is meant by megger? 3. From where power is generated for megger? 4. What is meant by defection coil? 5. What is meant by current coil?
34
Ex. No.1
STUDY OF ELECTRONIC COMPONENTS AND EQUIPMENTS RESISTOR, COLOUR CODING
Aim: To find the value the value of given resistors using colour coding Apparatus Required: 1. Resistors-various ranges Theory: Resistors: Resistors have three principal ratings: resistance in ohms, tolerance in percent, andpower dissipation in watts. Most of the resistors we have in the lab can dissipate watt and have tolerances of +or - 5 %.Resistance values are coded on the resistors with color bands. The first two bands give two significant digits of the value, the third band is a multiplier expressed as a power of 10, and the fourth band is the tolerance. The table below shows the color code. For example, red-red orange-gold is 22 Kohms + or - 5 %. Sometimes watt is not enough for a circuit application and then a physically larger resistor is required. PROCEDURE: 1. Find the nominal value and the tolerance of each resistance using the color codes 2. Calculae the resistor values and using the digital multimeter as an ohmmeter, we can cross check and record the resistance of each. Tabular Column: Resistor Values: Resistor Nominal value / Tolerance R1 R2 R3
35
Result: Thus the value of the resistors is obtained by using the colour coding technique.
VIVA QUESTIONS: 1. What is a resistor? 2. What is the function of a resistor? 3. How will you find out the resistor value? 4. What is tolerance? 36
Ex. No.2 MEASUREMENT OF AC SIGNAL PARAMETER (PEAK-PEAK, RMS, TIME PERIOD AND FREQUENCY) USING CRO
Aim: To study the electronic components and equipments including the resistor and color coding and to measure the various AC signal parameters (Peak-peak, RMS, Time Period and frequency) using CRO Apparatus Required: 1. CRO 2. Function generator Formula used: 1. Peak to peak voltage 2. Maximum Voltage V(p-p) = No. of divisions X Volts/Divisions Vm = V(p-p) / 2 (V)
3. Root Mean Square Voltage VRMS = Vm / 2 (V) 4. Time period (T) = No. of divisions X Time/Divisions (Sec) 5. Frequency (f) = 1/T (Hz) AC Sine Waveform
37
Tabular Column: Peak to peak Voltage measurement No of Divisions Volts/ Divisions Peak to Peak voltage V(p-p) (Volts) RMS voltage VRMS (Volts)
Time period measurement No of Divisions Time/ Divisions Time period (s) Frequency (HZ)
Theory: A sinusoidal signal is a general sine function. An electrical signal is a voltage or current which conveys information, usually it means a voltage. The term can be used for any voltage or current in a circuit. The voltage-time graph above shows the various properties of an electrical signal. In addition to the properties labelled on the graph, there is frequency which is the number of cycles per second. The diagram shows a sine wave but these properties apply to any signal with a constant shape. Amplitude is the maximum voltage reached by the signal. It is measured in volts, V. Peak voltage is another name for amplitude. Peak-peak voltage is twice the peak voltage (amplitude). When reading an oscilloscope trace it is usual to measure peak-peak voltage. the peak-to-peak value of the volage is simply the difference between the largest voltage (usually positive) and the smallest voltage (usually negative).
38
Time period is the time taken for the signal to complete one cycle. It is measured in seconds (s), but time periods tend to be short so milliseconds (ms) and microseconds (s) are often used. 1ms = 0.001s and 1s = 0.000001s. Frequency is the number of cycles per second. It is measured in hertz (Hz), but frequencies tend to be high so kilohertz (kHz) and megahertz (MHz) are often used. 1kHz = 1000Hz and 1MHz = 1000000Hz.
RMS value is the effective value of a varying voltage or current. It is the equivalent steady DC (constant) value which gives the same effect
Procedure: 1. AC signal is given as an input to CRO. 2. The CRO display is noted. 3. From the display the various parameters like peak-peak voltage, maximum voltage and time period are noted. 4. By using the formulas, the RMS value and frequency are calculated.
Result: Thus the various AC signal parameters (Peak-peak, RMS, Period and frequency) were measured using CRO.
39
VIVA QUESTIONS: 1. What is meant by AC supply? 2. What is peak to peak voltage? 3. What is rms voltage? 4. What is maximum voltage? 5. What is Frequency? 6. How is the time period measured?
40
Ex. No.3
AIM:
To study various logic gates AND, OR, NOT, X-OR APPARATUS REQUIRED: S.No. Name 1 IC7404,IC7408,IC7432 2 Regulated power supply 3 Breadboard 4 Resistor 5 LED 6 Connecting wires
Specification (0-30) V 1K
Quantity 1 1 1 1 1 10
THEORY: AND Gate The AND gate performs logical multiplication, commonly known as AND function. The AND gate is composed of two or more inputs and a single output. The output of AND gate is high (1) only when all the inputs are high (1) and the output is low (0) when any one of the inputs are low (0).
41
OR Gate The OR gate performs logical addition, commonly known as OR function. The OR gate has two or more inputs and only one output. The operation of OR gate is such that a high (1) on the output is produced when any of the input is high (1) and the output is low (0) only when all the inputs are low (0).
NOT gate The NOT gate performs a basic function called inversion or complementation. The purpose of gate is to change one logic level to opposite level. It has one input and one output. When a high level is applied to an inverter input, a low level will appear at its output and vice-versa.
42
X-OR gate It has two or more inputs and only one output. When all the inputs are high or low the output is low. If any one of the input is high the output also high. The X-OR gate output expression is Y = A B + AB .
43
3. Truth table is verified for various gates by giving different input and obtaining the outputs.
RESULT: Thus the logic gates AND, OR, NOT, X-OR gates were studied.
VIVA QUESTIONS 1. 2. 3. 4. 5. 6. 7. What are the universal gates Draw the truth table of AND gate. Draw the truth table of NOT gate. Draw the truth table of OR gate. How many gates will be there in a IC 7404 chip ? What gate does the IC 7408 consist of? What are the 7th and 14th pin in all the gates? 44
Ex. No.4.
Aim:
To generate a clock signal in Astable Multivibrator using 555 timer. Apparatus Required: S.No 1 2 3 4 5 6 7 Theory: Timing resistor is split into Ra and Rb. Pin 7 is connected to the junction of Ra and Rb along with power supply Vcc. External timing capacitor C charges towards Vcc with time constant (Ra + Rb)C. During this time, the output at the pin 3 is high. When the capacitor voltage equals to 2/3 Vcc, the upper comparator trigger the control flip-flop. Formula used: 1. Ton = 0.69 ((Ra + Rb)C 2. Toff = 0.69 RbC 3. T = Ton + Toff Equipment Required 555 Timer IC Resistance Capacitors CRO RPS (0-30)V Bread board Connecting wires Quantity 1 6.8KOhm,3.3KOhm 0.01micro Far 0.101micro Far 1 1 1 Type
WW
45
Circuit Diagram +5 V
6.8 K
RA 7 8 4 3
VO
3.3 K
RB 6 C = 0.1f 2
IC 555
1 5 CRO
VC
0.01f
Tabular Column Sl.No Resistance values K ON time Ton (Sec) OFF time Toff (Sec) Total time
Ton
+ Toff
(Sec)
46
Procedure: 1. Connections are made as per the circuit diagram. 2. +5 Volts is given to the Vcc terminal. 3. ton , toff values are calculated from the given formula. 4. The graph is drawn. Result: Thus a clock signal was generated using 555 timer IC for different values of resistances.
47
Viva Questions 1. What is a clock signal? 2. What are the applications of Clock signal? 3. What is the purpose of CRO? 4. Can we generate clock signal without using 555 timer? 5. What is the use of triggering signal , Threshold and control voltage?
48
Ex. No.5.
Aim: To practice soldering for the given electronic circuit by assembling the resistors and capacitors in the given Printed Circuit Board (PCB). Materials required: 1. PCB Board for given circuit 2. Soldering iron 3. Solder 4. Flux 5. Nose Plier 6. Resistors 7. Capacitor Given circuit
R1
C1
R2
Drawing
R1
C1
R2
R1
C1
R2
Front side of the PCB board Procedure: Soldering 1. The given electronic circuit is studied. 2. The PCB board is cleaned. 3. The tip of the soldering iron is cleaned before heating and also the resistors and capacitor which is to be soldered is cleaned. 4. The soldering iron is heated and the solder is applied to the tip of it. 5. The resistor (R) leads are bent to fit the holes on the board and they are inserted in the holes of the board as per the circuit diagram. 6. The hot tip is applied to the joints and the solder is applied. 7. The soldering tip is removed and the resistor is hold tightly till the solder is cooled and set. 8. The excess component lead is trimmed with side cutter. 9. The above steps are repeated to fix the other resistor and capacitor in the circuit De-Soldering 1. The tip of the soldering iron is placed on the resistor- board joint until the solder is melt. 2. When the solder is melted the resistor is removed with a tweezers and the molten solder is removed. 3. The above steps are repeated to remove the other resistor and capacitor. 4. The resistors and capacitors are cleaned. Result: Thus the soldering and de-soldering practice is done for the given electronic circuit.
50
VIVA QUESTIONS 1. What is a Resistor? 2. What is a capacitor? 3. What is Soldering and De-Soldering? 4. What is a PCB? State the use of PCB? 5. What are the uses of soldering and de-soldering?
51
Ex. No.6(a)
EQUIPMENTS REQUIRED: SL.NO. NAME OF THE 1. 2. 3. 4. 5. 6. FORMULAE USED: Ripple Factor, = (Vrms / Vdc)2 - 1 Where, Vrms = The rms value of the a.c component of the output voltage Vdc = The average or d.c value of the output voltage. HALF WAVE RECTIFIER: Vdc = Vm/2 Vrms = Vm/2 Theory: A rectifier is defined as a electronic device used for converting AC voltage into unidirectional voltage. A rectifier utilizes unidirectional conduction devices like Vacuum diode or PN junction diode. EQUIPMENT Transformer Capacitor Resistor PN junction diode Bread Board CRO RANGE 12v-0v-12v 0.1 F 470 IN 4007 QUANTITY 1 2 1 2 1 1
It converts an ac voltage into a pulsating DC voltage using only one half of the applied ac voltage. The rectifying diode conducts during one half of the ac cycle. During positive half cycle of the input signal the anode of diode becomes positive with respect to cathode and hence the diode conducts. For an ideal diode the forward voltage drop is zero so the whole input voltage appears across the load. During negative half of the input signal the anode of the diode becomes negative with respect to cathode and hence the diode does not conduct. For an ideal diode the impedance offered by the diode is unity so the whole input voltage drop across diode. Hence voltage drop across RL is zero. CIRCUIT DIAGRAM Half Wave Rectifier
MODEL GRAPH: 53
TABULATION: TYPE OF RECTIFIER Half Wave Rectifier Vm Time Period Ripple factor
PROCEDURE: 1.Connect the circuit as per the circuit diagram. 2.Connect the CRO across the load. 3.From the waveform in the CRO screen, note down the amplitude and frequency along with multiplication factor. 4.Calculate the ripple factor.
RESULT: Thus the input & output waveforms are drawn for half wave rectifiers and ripple factor calculated. VIVA QUESTIONS: 54
1. Define Rectifier ? 2. What is Half-Wave Rectifier ? 3. Define Ripple Factor ? 4. What type of output we get from HW Rectifier ? 5. What is the value of Ripple factor for HW Rectifier ? 6. What is the formulae for Vrms for HW Rectifier ? 7. What is the formulae for Vdc for HW Rectifier ?
Ex. No.6(b)
AIM: To study the ripple factor and regulation characteristics of a full wave rectifier .
EQUIPMENTS REQUIRED: SL.NO. NAME OF THE 1. 2. 3. 4. 5. 6. FORMULA USED: Ripple Factor, = (Vrms / Vdc)2 - 1 Where, Vrms = The rms value of the a.c component of the output voltage Vdc = The average or d.c value of the output voltage. EQUIPMENT Transformer Capacitor Resistor PN junction diode Bread Board CRO RANGE 12v-0v-12v 0.1 F 470 IN 4007 QUANTITY 1 2 1 2 1 1
FULL WAVE RECTIFIER: Vdc = 2 Vm/ Vrms = Vm/ 2 Theory: A rectifier is defined as a electronic device used for converting AC voltage into unidirectional voltage. A rectifier utilizes unidirectional conduction devices like Vacuum diode or PN junction diode. Full wave rectifier: It converts an AC voltage in to a pulsating DC voltage using both half cycles of the applied AC voltage. It uses two diodes of which one conducts during positive half cycle 56
while the other conducts during negative half cycle. During positive half cycle of the input signal anode of the diode D1 becomes positive with respect to cathode and at the same time anode of the diode becomes negative. Hence D1 conducts and D2 will not conduct during positive half cycle. During negative half of the input anode of the diode D1 becomes negative and anode of diode D2 becomes positive. Hence D1 does not conduct and D2 will conduct. The load current flows through D2 and voltage drop across RL will be equal to the input voltage. PROCEDURE: 1.Connect the circuit as per the circuit diagram. 2.Connect the CRO across the load. 3.From the waveform in the CRO screen, note down the amplitude and frequency along with multiplication factor. 4.Calculate the ripple factor. CIRCUIT DIAGRAM FULL WAVE RECTIFIER
MODELGRAPH
57
TABULATION: TYPE OF RECTIFIER Full Wave Rectifier Vm Time Period Ripple factor
RESULT: Thus the input & output waveforms are drawn for full wave rectifiers and ripple factor calculated VIVA QUESTIONS: 1. Define Full wave rectifier ? 2. What is the formulae for Vdc for FW Rectifier ? 58
Ex. No. 1
AIM:
59
To study the PN junction diode characteristics under Forward & Reverse bias conditions. APPARATUS REQUIRED: S.No. 1 2 3 Name R.P.S Ammeter Voltmeter THEORY: A PN junction diode is a two terminal junction device. It conducts only in one direction (only on forward biasing). FORWARD BIAS: On forward biasing, initially no current flows due to barrier potential. As the applied potential exceeds the barrier potential the charge carriers gain sufficient energy to cross the potential barrier and hence enter the other region. The holes, which are majority carriers in the P-region, become minority carriers on entering the N-regions, and electrons, which are the majority carriers in the N-region, become minority carriers on entering the P-region. This injection of Minority carriers results in the current flow, opposite to the direction of electron movement. Range Type Qty COMPONENTS REQUIRED: S.No. 1 2 3 4 Name Diode Resistor Bread Board Wires Range Type Qty
60
REVERSE BIAS: On reverse biasing, the majority charge carriers are attracted towards the terminals due to the applied potential resulting in the widening of the depletion region. Since the charge carriers are pushed towards the terminals no current flows in the device due to majority charge carriers. There will be some current in the device due to the thermally generated minority carriers. The generation of such carriers is independent of the applied potential and hence the current is constant for all increasing reverse potential. This current is referred to as Reverse Saturation Current (IO) and it increases with temperature. When the applied reverse voltage is increased beyond the certain limit, it results in breakdown. During breakdown, the diode current increases tremendously. PROCEDURE: FORWARD BIAS: 1. Connect the circuit as per the diagram. 2. Vary the applied voltage V in steps of 0.1V. 3. Note down the corresponding Ammeter readings I. 4. Plot a graph between V & I OBSERVATIONS 1. Find the d.c (static) resistance = V/I. 2. Find the a.c (dynamic) resistance r = V / I (r = V/I) = V2 V1 . I 2 I1
3. Find the forward voltage drop = [Hint: it is equal to 0.7 for Si and 0.3 for Ge] REVERSE BIAS: 1. Connect the circuit as per the diagram. 2. Vary the applied voltage V in steps of 1.0V. 3. Note down the corresponding Ammeter readings I. 4. Plot a graph between V & I 5. Find the dynamic resistance r = V / I.
61
FORMULA FOR REVERSE SATURATION CURRENT (IO): Io = I/[exp( V/VT)]-1 Where VT is the voltage equivalent of Temperature = kT/q -k is Boltzmanns constant, q is the charge of the electron and T is the temperature in degrees Kelvin. =1 for Silicon and 2 for Germanium
470
(0-10)V RPS
+ -+
a a (0-100)mA, MC a -+ + a a A A A
+ -+
(0-15)V, MC
REVERSE BIAS:
470
(0-30)V RPS
+ -+
a a (0-500)A,MC a -+ + a a A A A
+ -+
(0-30)V, MC
Specification for 1N4001: Silicon Diode Peak Inverse Voltage: 50V Idc = 1A. Maximum forward voltage drop at 1 Amp is 1.1 volts Maximum reverse current @50 volts is 5A 62
S.No.
S..No.
Vb ( Volts)
I1 V1 V2 Ir (A) Vf (Volts)
RESULT: Forward and Reverse bias characteristics of the PN junction diode and the dynamic resistance under i) ii) iii) Forward bias = --------------------Reverse bias = ----------------------. Reverse Saturation Current = ----------------.
63
Ex. No. 2
AIM:
To determine the breakdown voltage of a given zener diode. APPARATUS REQUIRED: S.No. 1 2 3 Name R.P.S Ammeter Voltmeter THEORY: A properly doped crystal diode, which has a sharp breakdown voltage, is known as zener diode. FORWARD BIAS: On forward biasing, initially no current flows due to barrier potential. As the applied potential increases, it exceeds the barrier potential at one value and the charge carriers gain sufficient energy to cross the potential barrier and enter the other region. the holes ,which are majority carriers in p-region, become minority carriers on entering the Nregions and electrons, which are the majority carriers in the N-regions become minority carriers on entering the P-region. This injection of minority carriers results current, opposite to the direction of electron movement. REVERSE BIAS: When the reverse bias is applied due to majority carriers small amount of current (ie) reverse saturation current flows across the junction. As the reverse bias is increased to breakdown voltage, sudden rise in current takes place due to zener effect. Range Type Qty COMPONENTS REQUIRED: S.No. 1 2 3 4 Name zener diode Resistor Bread Board Wires Range Type Qty
ZENER EFFECT: 64
Normally, PN junction of Zener Diode is heavily doped. Due to heavy doping the depletion layer will be narrow. When the reverse bias is increased the potential across the depletion layer is more. This exerts a force on the electrons in the outermost shell. Because of this force the electrons are pulled away from the parent nuclei and become free electrons. This ionization, which occurs due to electrostatic force of attraction, is known as Zener effect. It results in large number of free carriers, which in turn increases the reverse saturation current PROCEDURE: FORWARD BIAS: 1. 2. 3. 4. 5. Connect the circuit as per the circuit diagram. Vary the power supply in such a way that the readings are taken in steps of 0.1V in the voltmeter till the needle of power supply shows 30V. Note down the corresponding ammeter readings. Plot the graph :V (vs) I. Find the dynamic resistance r = V / I.
REVERSE BIAS: 1. Connect the circuit as per the diagram. 2. Vary the power supply in such a way that the readings are taken in steps of 0.1V in the voltmeter till the needle of power supply shows 30V. 3. Note down the corresponding Ammeter readings I. 4. Plot a graph between V & I 5. Find the dynamic resistance r = V / I. 6. Find the reverse voltage Vr at Iz=20 mA.
CIRCUIT DIAGRAM: 65
FORWARD BIAS:
470
+ (0-10) V -
aaaaa
a a (0-10)mA a + a a A A A
a a a a a A+ A(0-15) V A a a a a a A A 1A
K
1 K
1K
+ (0-30) V -
aaaaa
a a a a a A+ A(0-10) V, MC A a a a a a A A A
66
VB Vr (V)
I1 V1 V2 (V) Ir (A) Vf
S.No.
RESULT: Forward and Reverse bias characteristics of the zener diode was studied and Forward bias dynamic resistance = --------------------Reverse bias dynamic resistance = ---------------------The reverse voltage at Iz =20 mA determined from the reverse characteristics of the Zener diode is --------------------------.
67
VIVA VOICE QUESTION SEMICONDUCTOR DIODE AND ZENER DIODE 1. Define knee voltage of a diode.
2. Draw VI characteristics of PN junction diode. 3. Although Zener diode is operated in the reverse breakdown region, but it does not
68
EXPT.NO: 3
CALIBRATION OF VOLTMETER OBJECTIVES a) To calibrate the given voltmeter by using a standard voltmeter. b) To find the error and percentage error in the given voltmeter with respect to the standard voltmeter. c) To draw the graphs showing the error vs. non standard voltmeter reading APPARATUS REQUIRED SL. NO 1 2 3 APPARATUS Standard Voltmeter Non Standard Voltmeter Auto transformer CIRCUIT DIAGRAM: RANGE 0-300 V AC 0-300 V AC 230 V, Single Phase TYPE MI MI ------QUANTITY 1 1 1
69
TABULAR COLUMN SL.NO STANDARD VOLTMETER READING VS VOLTS NON STANDARD VOLTMETER READING VN VOLTS ERROR MAKE VN - VS UP VS - VN PERCENTAGE ERROR 100
FORMULA : Standard Voltmeter Reading VS = . V Non Standard Voltmeter Reading VN= V Error (VN - VS) = Make up Error or Correction Error = Percentage Error (VN - VS) X 100 / VS = PROCEDURE i) ii) iii) Connections are made as per the circuit diagram. The readings of the two voltmeter are taken by varying the voltage. Six or more readings are noted and tabulated
RESULT 70
i) ii)
The given voltmeter has been calculated using the standard voltmeter and the error had been calculated from each reading. The following graphs have been plotted. a) Standard vs. Non Standard voltmeter reading b) Error vs. Non Standard voltmeter reading
Viva -Voce
1. State the type of voltmeter 2. How the voltmeter to be connected in a circuit 3. State the purpose of Autotransformer in the circuit 4. State the reasons for error in voltmeter 5. State the precaution to be observed when conducting the experiment.
71
EXPT.NO: 4
experiment
Value added
CALIBRATION OF AMMETER OBJECTIVES To calibrate the given ammeter by using a standard ammeter. To find the error and percentage error in the given ammeter with respect to the standard ammeter. To draw the graphs showing the error vs. non standard ammeter reading.
APPARATUS REQUIRED SL. NO 1 2 3 4 APPARATUS Standard Ammeter Non Standard Ammeter Standard Voltmeter Lamp Load RANGE 0-10 A 0-10 A 0-300 V AC 0 2000 W TYPE MI MI MI --QUANTITY 1 1 1 1
CIRCUIT DIAGRAM:
72
FORMULA : Standard Ammeter Reading A S = . A Non Standard Ammeter Reading A N= A Error (A N - A S) = Make up Error or Correction Error = Percentage Error (A N - A S) X 100 / A S = PROCEDURE: i) ii) iii) iv) RESULT: i) ii) The given Ammeter has been calculated using the standard ammeter and the error had been calculated from each reading. The following graphs have been plotted. a) Standard vs. Non Standard Ammeter reading b) Error vs. Non Standard Ammeter reading. Connections are made as per the circuit diagram. Supply is switched on and required voltage of 230V is kept fixed. The readings on the standard and non standard ammeter are noted by applying the lamp load. Six or more readings are taken and the readings are tabulated.
73
Viva Voce 1. 2. 3. 4. 5. State the type of Ammeter How the Ammeter to be connected in a circuit State the purpose of Autotransformer in the circuit State the reasons for error in Ammeter State the precaution to be observed when conducting the experiment.
74