Some user agents have music devices, such as synthesizers, keyboard and other controllers, and drum machines connected to their host computer or device. The widely adopted Musical Instrument Digital Interface (MIDI) protocol enables electronic musical instruments, controllers and computers to communicate and synchronize with each other. MIDI does not transmit audio signals: instead, it sends event messages about musical notes, controller signals for parameters such as volume, vibrato and panning, cues and clock signals to set the tempo, and system-specific MIDI communications (e.g. to remotely store synthesizer-specific patch data). This same protocol has become a standard for non-musical uses, such as show control, lighting and special effects control.

This specification defines an API supporting the MIDI protocol, enabling web applications to enumerate and select MIDI input and output devices on the client system and send and receive [=MIDI messages=]. It is intended to enable non-music MIDI applications as well as music ones, by providing low-level access to the [=MIDI devices=] available on the users' systems. The Web MIDI API is not intended to describe music or controller inputs semantically; it is designed to expose the mechanics of MIDI input and output interfaces, and the practical aspects of sending and receiving [=MIDI messages=], without identifying what those actions might mean semantically (e.g., in terms of "modulate the vibrato by 20Hz" or "play a G#7 chord", other than in terms of changing a controller value or sending a set of note-on messages that happen to represent a G#7 chord).

To some users, "MIDI" has become synonymous with Standard MIDI Files and General MIDI. That is not the intent of this API; the use case of simply playing back a .SMF file is not within the purview of this specification (it could be considered a different format to be supported by the HTML [^audio^] element, for example). The Web MIDI API is intended to enable direct access to devices that respond to MIDI - controllers, external synthesizers or lighting systems, for example. The Web MIDI API is also explicitly designed to enable a new class of applications on the web that can respond to MIDI controller inputs - using external hardware controllers with physical buttons, knobs and sliders (as well as musical controllers like keyboard, guitar or wind instrument controllers) to control web applications.

The Web MIDI API is also expected to be used in conjunction with other APIs and elements of the web platform, notably the [=Web Audio API=]. This API is also intended to be familiar to users of MIDI APIs on other systems, such as Apple's CoreMIDI and Microsoft's Windows MIDI API.

Introduction

The Web MIDI API specification defines a means for web developers to enumerate, manipulate and access [=MIDI devices=] - for example, interfaces that may provide hardware MIDI ports with other devices plugged in to them and USB devices that support the USB-MIDI specification. Having a Web API for MIDI enables web applications that use existing software and hardware synthesizers, hardware music controllers and light systems and other mechanical apparatus controlled by MIDI. This API has been defined with this wide variety of use cases in mind.

The approaches taken by this API are similar to those taken in Apple's CoreMIDI API and Microsoft's Windows MIDI API; that is, the API is designed to represent the low-level software protocol of MIDI, in order to enable developers to build powerful MIDI software on top. The API enables the developer to enumerate input and output interfaces, and send and receive [=MIDI messages=], but (similar to the aforementioned APIs) it does not attempt to semantically define or interpret [=MIDI messages=] beyond what is necessary to robustly support current devices.

The Web MIDI API is not intended to directly implement high-level concepts such as sequencing; it does not directly support Standard MIDI Files, for example, although a Standard MIDI File player can be built on top of the Web MIDI API. It is also not intended to semantically capture patches or controller assignments, as General MIDI does; such interpretation is outside the scope of the Web MIDI API (though again, General MIDI can easily be utilized through the Web MIDI API).

This specification defines conformance criteria that apply to a single product: the [=user agent=] that implements the interfaces that it contains.

Implementations that use ECMAScript to implement the APIs defined in this specification MUST implement them in a manner consistent with the ECMAScript Bindings defined in the Web IDL specification [[WEBIDL]], as this specification uses that specification and terminology.

Terminology

The Web Audio API and its associated interfaces and concepts are defined in [[webaudio]].

The terms MIDI, MIDI device, MIDI input port, MIDI output port, MIDI interface, MIDI message, System Real Time and System Exclusive are defined in [[MIDI]].

Valid MIDI message is defined in [[MIDI]]. The following may be used as a non-normative guide:

Obtaining Access to [=MIDI Devices=]

Permissions Integration

The Web Midi API is a [=powerful feature=] that is identified by the [=powerful feature/name=] "midi". It integrates with [[[Permissions]]] by defining the following permission-related flags:

[=powerful feature/permission descriptor type=]
              dictionary MidiPermissionDescriptor : PermissionDescriptor {
                boolean sysex = false;
              };
            

`{name: "midi", sysex: true}` is [=PermissionDescriptor/stronger than=] `{name: "midi", sysex: false}`.

Permissions Policy Integration

The Web Midi API defines a [=policy-controlled feature=] named "midi" which has a [=policy-controlled feature/default allowlist=] of `'self'`.

Extensions to the Navigator interface

            partial interface Navigator {
              [SecureContext]
              Promise <MIDIAccess> requestMIDIAccess(optional MIDIOptions options = {});
            };
          
requestMIDIAccess() method

When invoked, returns a Promise object representing a request for access to [=MIDI devices=] on the user's system.

Requesting MIDI access SHOULD prompt the user for access to MIDI devices, particularly if [=System Exclusive=] access is requested. In some scenarios, this permission may have already been implicitly or explicitly granted, in which case this prompt may not appear. If the user gives express permission or the call is otherwise approved, the vended Promise is resolved. The underlying system may choose to allow the user to select specific [=MIDI interfaces=] to expose to this API (i.e. pick and choose interfaces on an individual basis), although this is not required. The system may also choose to prompt (or not) based on whether [=System Exclusive=] support is requested, as [=System Exclusive=] access has greater privacy and security implications.

If the user declines or the call is denied for any other reason, the Promise is rejected with a {{DOMException}} parameter.

When the {{requestMIDIAccess()}} method is called, the user agent MUST run the following steps:

  1. Let promise be a new Promise object and resolver be its associated resolver.

  2. Return promise and run the following steps asynchronously.

  3. Let document be the calling context's [=Document=].

  4. If document is not [=allowed to use=] the [=policy-controlled feature=] named midi, jump to the step labeled failure below.

  5. Optionally, e.g. based on a previously-established user preference, for security reasons, or due to platform limitations, jump to the step labeled failure below.

  6. Optionally, e.g. based on a previously-established user preference, jump to the step labeled success below.

  7. Prompt the user in a user-agent-specific manner for permission to provide the entry script's origin with a {{MIDIAccess}} object representing control over user's [=MIDI devices=]. This prompt may be contingent upon whether [=System Exclusive=] support was requested, and may allow the user to enable or disable that access.

    If permission is denied, jump to the step labeled failure below. If the user never responds, this algorithm will never progress beyond this step. If permission is granted, continue the following steps.

  8. success: Let access be a new {{MIDIAccess}} object. (It is possible to call requestMIDIAccess() multiple times; this may prompt the user multiple times, so it may not be best practice, and the same instance of MIDIAccess will not be returned each time.)

  9. Call resolver's accept(value) method with access as value argument.

  10. Terminate these steps.

  11. failure: Let error be a new {{DOMException}}. This exception's .name should be {{"NotAllowedError"}} if the user or their security settings denied the application from creating a MIDIAccess instance with the requested options, or if the error is the result of document not being [=allowed to use=] the feature, {{"AbortError"}} if the page is going to be closed for a user navigation, {{"InvalidStateError"}} if the underlying systems raise any errors, or otherwise it should be {{"NotSupportedError"}}.

  12. Call resolver's reject(value) method with error as value argument.

MIDIOptions Dictionary

This dictionary contains optional settings that may be provided to the {{requestMIDIAccess()}} request.

            dictionary MIDIOptions {
              boolean sysex;
              boolean software;
            };
          
sysex

This member informs the system whether the ability to send and receive [=System Exclusive=] messages is requested or allowed on a given {{MIDIAccess}} object. On the option passed to {{requestMIDIAccess()}}, if this member is set to true, but [=System Exclusive=] support is denied (either by policy or by user action), the access request will fail with a {{"NotAllowedError"}} error. If this support is not requested (and allowed), the system will throw exceptions if the user tries to send [=System Exclusive=] messages, and will silently mask out any [=System Exclusive=] messages received on the port.

software

This member informs the system whether the ability to utilize any software synthesizers installed in the host system is requested or allowed on a given {{MIDIAccess}} object. On {{requestMIDIAccess()}}, if this member is set to true, but software synthesizer support is denied (either by policy or by user action), the access request will fail with a {{"NotAllowedError"}} error. If this support is not requested, the system should not include any software synthesizers in the {{MIDIAccess}} exposure of available ports.

Note that may result in a two-step request procedure if software synthesizer support is desired but not required - software synthesizers may be disabled when MIDI hardware device access is allowed.

The MIDI API

MIDIInputMap Interface

          [SecureContext, Exposed=(Window,Worker)] interface MIDIInputMap {
            readonly maplike <DOMString, MIDIInput>;
          };
        

The {{MIDIInputMap}} is a maplike interface whose value is a {{MIDIInput}} instance and key is its ID.

This type is used to represent all the currently available [=MIDI input ports=].

MIDIOutputMap Interface

          [SecureContext, Exposed=(Window,Worker)] interface MIDIOutputMap {
            readonly maplike <DOMString, MIDIOutput>;
          };
        

The {{MIDIOutputMap}} is a maplike interface whose value is a {{MIDIOutput}} instance and key is its ID.

This type is used to represent all the currently available [=MIDI output ports=].

MIDIAccess Interface

This interface provides the methods to list MIDI input and output devices, and obtain access to an individual device.

        [SecureContext, Exposed=(Window,Worker), Transferable] interface MIDIAccess: EventTarget {
          readonly attribute MIDIInputMap inputs;
          readonly attribute MIDIOutputMap outputs;
          attribute EventHandler onstatechange;
          readonly attribute boolean sysexEnabled;
        };
      
inputs
The [=MIDI input ports=] available to the system.
outputs
The [=MIDI output ports=] available to the system.
onstatechange

The handler called when a new port is connected or an existing port changes the state attribute.

This [=event handler=], of type {{MIDIConnectionEvent}}, MUST be supported by all objects implementing the {{MIDIAccess}} interface.

It is important to understand that leaving an {{EventHandler}} attached to this object will prevent it from being garbage-collected; when finished using the {{MIDIAccess}}, you should remove any {{onstatechange}} listeners.

Whenever a previously unavailable MIDI port becomes available for use, or an existing port changes the state attribute, the user agent SHOULD run the following steps:

  1. Let |port:MIDIPort| be the {{MIDIPort}} corresponding to the newly-available, or the existing port.
  2. [=Fire an event=] named "statechange" at the {{MIDIAccess}}, using {{MIDIConnectionEvent}} with {{MIDIConnectionEvent/port}} set to |port|.
sysexEnabled
This attribute informs the user whether [=System Exclusive=] support is enabled on this MIDIAccess.

MIDIPort Interface

This interface represents a MIDI input or output port.

        [SecureContext, Exposed=(Window,Worker)] interface MIDIPort: EventTarget {
          readonly attribute DOMString id;
          readonly attribute DOMString? manufacturer;
          readonly attribute DOMString? name;
          readonly attribute MIDIPortType type;
          readonly attribute DOMString? version;
          readonly attribute MIDIPortDeviceState state;
          readonly attribute MIDIPortConnectionState connection;
          attribute EventHandler onstatechange;
          Promise <MIDIPort> open();
          Promise <MIDIPort> close();
        };
      
id

A unique ID of the port. This can be used by developers to remember ports the user has chosen for their application. The User Agent MUST ensure that the {{MIDIPort/id}} is unique to only that port. The User Agent SHOULD ensure that the id is maintained across instances of the application - e.g., when the system is rebooted - and when a device is removed from the system. Applications may want to cache these ids locally to re-create a MIDI setup. Some systems may not support completely unique persistent identifiers; in such cases, it will be more challenging to maintain identifiers when another interface is added or removed from the system. (This might throw off the index of the requested port.) It is expected that the system will do the best it can to match a port across instances of the MIDI API: for example, an implementation may opaquely use some form of hash of the port interface manufacturer, name and index as the id, so that a reference to that port id is likely to match the port when plugged in. Applications may use the comparison of id of MIDIPorts to test for equality.

manufacturer

The manufacturer of the port.

name

The system name of the port.

type

A descriptor property to distinguish whether the port is an input or an output port. For {{MIDIOutput}}, this MUST be "output". For {{MIDIInput}}, this MUST be "input".

version

The version of the port.

state
The state of the device.
connection
The state of the connection to the device.
onstatechange

The handler called when an existing port changes its state or connection attributes.

This [=event handler=], of type "statechange", MUST be supported by all objects implementing {{MIDIPort}} interface.

It is important to understand that leaving an {{EventHandler}} attached to this object will prevent it from being garbage-collected; when finished using the {{MIDIPort}}, you should remove any {{MIDIPort/onstatechange}} listeners.

open

Makes the [=MIDI device=] corresponding to the {{MIDIPort}} explicitly available. Note that this call is NOT required in order to use the {{MIDIPort}}- calling send() on a {{MIDIOutput}} or attaching a MIDIMessageEvent handler on a {{MIDIInput}} will cause an implicit open(). The underlying implementation may not need to do anything in response to this call. However, some underlying implementations may not be able to support shared access to [=MIDI devices=], so using explicit open() and close() calls will enable MIDI applications to predictably control this exclusive access to devices.

When invoked, this method returns a Promise object representing a request for access to the given MIDI port on the user's system.

If the port device has a state of "connected", when access to the port has been obtained (and the port is ready for input or output), the vended Promise is resolved.

If access to a connected port is not available (for example, the port is already in use in an exclusive-access-only platform), the Promise is rejected (if any) is invoked.

If open() is called on a port that is "disconnected", the port's .connection will transition to "pending", until the port becomes "connected" or all references to it are dropped.

When this method is called, the user agent MUST run the algorithm to open a MIDIPort:

  1. Let promise be a new Promise object and resolver be its associated resolver.

  2. Return promise and run the following steps asynchronously.

  3. Let port be the given {{MIDIPort}} object.

  4. If the device's connection is already "open" (e.g. open() has already been called on this {{MIDIPort}}, or the port has been implicitly opened), jump to the step labeled success below.

  5. If the device's connection is "pending" (i.e. the connection had been opened and the device was subsequently disconnected), jump to the step labeled success below.

  6. If the device's state is "disconnected", change the connection attribute of the {{MIDIPort}} to "pending", and enqueue a new MIDIConnectionEvent to the statechange handler of the {{MIDIAccess}} and to the statechange handler of the {{MIDIPort}} and jump to the step labeled success below.

  7. Attempt to obtain access to the given [=MIDI device=] in the system. If the device is unavailable (e.g. is already in use by another process and cannot be opened, or is disconnected), jump to the step labeled failure below. If the device is available and access is obtained, continue the following steps.

  8. Change the connection attribute of the MIDIPort to "open", and enqueue a new {{MIDIConnectionEvent}} to the statechange handler of the {{MIDIAccess}} and to the statechange handler of the {{MIDIPort}}.

  9. If this port is an output port and has any pending data that is waiting to be sent, asynchronously begin sending that data.

  10. success: Call resolver's accept(value) method with port as value argument.

  11. Terminate these steps.

  12. failure: Let error be a new {{DOMException}}. This exception's .name should be "InvalidAccessError" if the port is unavailable.

  13. Call resolver's reject(value) method with error as value argument.

close

Makes the [=MIDI device=] corresponding to the {{MIDIPort}} explicitly unavailable (subsequently changing the state from "open" to "closed"). Note that successful invocation of this method will result in [=MIDI messages=] no longer being delivered to MIDIMessageEvent handlers on a {{MIDIInput}} (although setting a new handler will cause an implicit open()).

The underlying implementation may not need to do anything in response to this call. However, some underlying implementations may not be able to support shared access to [=MIDI devices=], and the explicit close() call enables MIDI applications to ensure other applications can gain access to devices.

When invoked, this method returns a Promise object representing a request for access to the given MIDI port on the user's system. When the port has been closed (and therefore, in exclusive access systems, the port is available to other applications), the vended Promise is resolved. If the port is disconnected, the Promise is rejected.

When the close() method is called, the user agent MUST run the following steps:

  1. Let promise be a new Promise object and resolver be its associated resolver.

  2. Return promise and run the following steps asynchronously.

  3. Let port be the given {{MIDIPort}} object.

  4. If the port is already closed (its .connection is "closed" - e.g. the port has not yet been implicitly or explicitly opened, or close() has already been called on this {{MIDIPort}}), jump to the step labeled closed below.

  5. If the port is an input port, skip to the next step. If the output port's .state is not "connected", clear all pending send data and skip to the next step. Clear any pending send data in the system with timestamps in the future, then finish sending any send messages with no timestamp or with a timestamp in the past or present, prior to proceeding to the next step.

  6. Close access to the port in the underlying system if open, and release any blocking resources in the underlying system.

  7. Change the connection attribute of the MIDIPort to "closed", and enqueue a new {{MIDIConnectionEvent}} to the statechange handler of the {{MIDIAccess}} and to the statechange handler of the {{MIDIPort}}.

  8. closed: Call resolver's accept(value) method with port as value argument.

  9. Terminate these steps.

Whenever the MIDI port corresponding to the {{MIDIPort}} changes the state attribute, the user agent SHOULD run the following steps:

  1. Let |port:MIDIPort| be the {{MIDIPort}}.

  2. [=Fire an event=] named statechange at the {{MIDIPort}}, and statechange at the {{MIDIAccess}}, using {{MIDIConnectionEvent}} with the {{MIDIConnectionEvent/port}} attribute set to |port|.

MIDIInput Interface

          [SecureContext, Exposed=(Window,Worker)] interface MIDIInput: MIDIPort {
            attribute EventHandler onmidimessage;
          };
        
onmidimessage

This [=event handler=], of type "midimessage", MUST be supported by all objects implementing {{MIDIInput}} interface.

If the handler is set and the state attribute is not "opened", underlying implementation tries to make the port available, and change the state attribute to "opened". If succeeded, {{MIDIConnectionEvent}} is delivered to the corresponding MIDIPort and {{MIDIAccess}}.

Whenever the MIDI port corresponding to the {{MIDIInput}} finishes receiving one or more [=MIDI messages=], the user agent MUST run the following steps:

  1. Let |port:MIDIInput| be the {{MIDIInput}}.

  2. If the {{MIDIAccess}} did not enable [=System Exclusive=] access, and the message is a [=System Exclusive=] message, abort this process.

  3. [=Fire an event=] named "midimessage" at |port|, using {{MIDIMessageEvent}} with the {{Event/timeStamp}} attribute set to the time the message was received by the system, and with the {{MIDIMessageEvent/data}} attribute set to a {{Uint8Array}} of MIDI data bytes representing a single [=MIDI message=].

It is specifically noted that MIDI [=System Real Time=] messages may actually occur in the middle of other messages in the input stream; in this case, the [=System Real Time=] messages will be dispatched as they occur, while the normal messages will be buffered until they are complete (and then dispatched).

MIDIOutput Interface

          [SecureContext, Exposed=(Window,Worker)] interface MIDIOutput : MIDIPort {
            undefined send(sequence<octet> data, optional DOMHighResTimeStamp timestamp = 0);
            undefined clear();
          };
          
send

Enqueues the message to be sent to the corresponding MIDI port. The underlying implementation will (if necessary) coerce each member of the sequence to an unsigned 8-bit integer. The use of sequence rather than a Uint8Array enables developers to use the convenience of output.send( [ 0x90, 0x45, 0x7f ] ); rather than having to create a Uint8Array, e.g. output.send( new Uint8Array( [ 0x90, 0x45, 0x7f ] ) );

The data contains one or more complete, [=valid MIDI messages=]. Running status is not allowed in the data, as underlying systems may not support it.

If data is not a valid sequence or does not contain a [=valid MIDI message=], throw a TypeError exception.

If data is a [=System Exclusive=] message, and the {{MIDIAccess}} did not enable [=System Exclusive=] access, throw an InvalidAccessError exception.

If the port is "disconnected", throw an InvalidStateError exception.

If the port is "connected" but the connection is "closed", asynchronously try to [=open the port=].

sequence<octet> data
The data to be enqueued, with each sequence entry representing a single byte of data.
optional DOMHighResTimeStamp timestamp
The time at which to begin sending the data to the port (as a {{DOMHighResTimeStamp}} - a number of milliseconds measured relative to the navigation start of the document). If timestamp is set to zero (or another time in the past), the data is to be sent as soon as possible.
clear

Clears any enqueued send data that has not yet been sent from the {{MIDIOutput}}'s queue. The implementation will need to ensure the MIDI stream is left in a good state, so if the output port is in the middle of a sysex message, a sysex termination byte (0xf7) should be sent.

MIDIPortType Enum

          enum MIDIPortType {
            "input",
            "output",
          };
        
input
If a {{MIDIPort}} is an input port, the type member MUST be this value.
output
If a {{MIDIPort}} is an output port, the type member MUST be this value.

MIDIPortDeviceState Enum

        enum MIDIPortDeviceState {
          "disconnected",
          "connected",
        };
      
disconnected
The device that {{MIDIPort}} represents is disconnected from the system. When a device is disconnected from the system, it should not appear in the relevant map of input and output ports.
connected
The device that {{MIDIPort}} represents is connected, and should appear in the map of input and output ports.

MIDIPortConnectionState Enum

        enum MIDIPortConnectionState {
          "open",
          "closed",
          "pending",
        };
      
open
The device that {{MIDIPort}} represents has been opened (either implicitly or explicitly) and is available for use.
closed
The device that {{MIDIPort}} represents has not been opened, or has been explicitly closed. Until a {{MIDIPort}} has been opened either explicitly (through {{MIDIPort.open()}}) or implicitly (by adding a midimessage event handler on an input port, or calling {{MIDIOutput.send()}} on an output port, this should be the default state of the device.
pending
The device that {{MIDIPort}} represents has been opened (either implicitly or explicitly), but the device has subsequently been disconnected and is unavailable for use. If the device is reconnected, prior to sending a statechange event, the system should attempt to reopen the device (following the [=algorithm to open a MIDIPort=]); this will result in either the connection state transitioning to "open" or to "closed".

MIDIMessageEvent Interface

An event object implementing this interface is passed to a {{MIDIInput}}'s onmidimessage handler when [=MIDI messages=] are received. Note that the DOM {{Event}} timeStamp attribute is defined as a {{DOMHighResTimeStamp}}, and represents the high-resolution time of when the event was received or is to be sent.

        [SecureContext, Exposed=(Window,Worker)]
        interface MIDIMessageEvent : Event {
          constructor(DOMString type, optional MIDIMessageEventInit eventInitDict = {});
          readonly attribute Uint8Array? data;
        };
      
data

A Uint8Array containing the MIDI data bytes of a single [=MIDI message=].

MIDIMessageEventInit Dictionary

          dictionary MIDIMessageEventInit: EventInit {
            Uint8Array data;
          };
        
data

A Uint8Array containing the MIDI data bytes of a single [=MIDI message=].

MIDIConnectionEvent Interface

An event object implementing this interface is passed to a {{MIDIAccess}}' onstatechange handler when a new port becomes available (for example, when a [=MIDI device=] is first plugged in to the computer), when a previously-available port becomes unavailable, or becomes available again (for example, when a [=MIDI interface=] is disconnected, then reconnected) and (if present) is also passed to the {{MIDIPort/onstatechange}} handlers for any {{MIDIPort}}s referencing the port.

When a {{MIDIPort}} is in the "pending" state and the device is reconnected to the host system, prior to firing a statechange event the [=algorithm to open a MIDIPort=] is run on it to attempt to reopen the port. If this transition fails (e.g. the Port is reserved by something else in the underlying system, and therefore unavailable for use), the connection state moves to "closed", else it transitions back to "open". This is done prior to the statechange event for the device state change so that the event will reflect the final connection state as well as the device state.

Some underlying systems may not provide notification events for device connection status; such systems may have long time delays as they poll for new devices infrequently. As such, it is suggested that heavy reliance on connection events not be used.

        [SecureContext, Exposed=(Window,Worker)]
        interface MIDIConnectionEvent : Event {
          constructor(DOMString type, optional MIDIConnectionEventInit eventInitDict = {});
          readonly attribute MIDIPort? port;
        };
      
port

The port that has been connected or disconnected.

MIDIConnectionEventInit Dictionary

          dictionary MIDIConnectionEventInit: EventInit {
            MIDIPort port;
          };
        
port

The port that has been connected or disconnected.

Privacy Considerations

Allowing the enumeration of the user's [=MIDI interfaces=] is a potential target for fingerprinting; that is, uniquely identifying a user by the specific [=MIDI interfaces=] they have connected.

Note that in this context what can be enumerated is the MIDI interfaces. This includes most devices connected to the host computer with USB, since USB-[=MIDI devices=] typically have their own [=MIDI interface=] and would be enumerated. An individual sampler or synthesizer [=MIDI device=] plugged into a [=MIDI interface=] with a 5-pin DIN cable would not be enumerated. The interfaces that could be fingerprinted are equivalent to MIDI "ports", and for each [=MIDI interface=] the API will expose the name of the device, manufacturer, and opaque identifier of the [=MIDI interface=].

Most systems have no [=MIDI interfaces=] attached. Few systems will have large numbers of [=MIDI interfaces=] attached. Thus, the additional fingerprinting exposure of enumerating MIDI devices is similar to the Gamepad API’s additional fingerprinting exposure through gamepad enumeration: typical users will have at most a few devices connected, their configuration may change, and the information exposed is about the interface itself (i.e., no user-configured data).

Security Considerations

The first [=MIDI devices=] were released in 1983, before the web platform and its security risks existed. Many [=MIDI devices=] are still in use long after their manufacturers stopped supporting them. [=MIDI=] has adapted to transports beyond the original serial connection, such as FireWire, USB, and Bluetooth. This poses a security challenge, with a long tail of devices from different eras that do not have official support but are still actively in use, connected to computers and the web in ways their designers did not expect.

Malicious Firmware Updates

One concerning theoretical attack involves malicious firmware updates for USB-[=MIDI devices=]. USB devices in general can do things based on their device descriptor, which is sent from the USB device itself. If a USB-[=MIDI device=]'s firmware can modify what descriptor is sent, it could make itself act as a human interface device. This could allow a malicious website to read or inject keystrokes or other events on the host computer, which could lead to a total compromise of the system.

The attack would proceed as follows:

  1. A malicious site tricks the user into granting Web MIDI permission.
  2. The malicious site enumerates the [=MIDI devices=] connected to the user's machine, and identifies a vulnerable device.
  3. The malicious site sends a pre-crafted set of [=MIDI messages=] to the vulnerable device, compromising the device by overwriting its firmware and adding a human interface device to its USB descriptor.
  4. The compromised device injects keystrokes to download or otherwise reproduce a pre-crafted security exploit and execute it, compromising the system.

In order to enable to the above attack, a [=MIDI device=] would need all of the following to be true:

[=MIDI devices=] that are vulnerable to malicious firmware updates but do not satisfy the other conditions cannot be used with this attack to compromise the host system. A malicious firmware update could still cause these [=MIDI devices=] to stop working or behave in undesired ways.

To mitigate this risk, implementers should emphasize the following in their implementations:

Explicitly allowing or blocking lists of known MIDI devices may also help mitigate this specific attack, but many small companies and individuals build MIDI devices, and many MIDI devices are no longer supported, so doing this would significantly reduce the usability of the Web MIDI API.

Additional Security Considerations

Separate from the fingerprinting concerns of identifying the available ports are concerns around sending and receiving [=MIDI messages=]. Those issues are explored in more depth below.

MIDI messages can be divided into [=System Exclusive=] messages, and short (non-[=System Exclusive=]) messages. [=System Exclusive=] messages can be further subdivided into Universal System Exclusive messages such as the commonly recognized MIDI Time Code and MIDI Sample Dump Standard, and device-specific messages like “patch control data for a Roland Jupiter-80 synthesizer” that do not apply to other devices.

Before discussing security concerns, it's useful to examine what scenarios are enabled by MIDI using these features:

The potential security impact of each of these is as follows:

Changelog

Changes since Working Draft 17 March 2015